CONNECTED NETWORK CABINETS, CLIMATE CONTROL & MONITORING PRODUCTS

Size: px
Start display at page:

Download "CONNECTED NETWORK CABINETS, CLIMATE CONTROL & MONITORING PRODUCTS"

Transcription

1 CONNECTED NETWORK CABINETS, CLIMATE CONTROL & MONITORING PRODUCTS R FRIEDHELM L O H GROUP

2 Partner With Rittal To Get... PERFECT CONNECTIONS No one in the world is better networked than Rittal. You see, Rittal is one of the world's leaders in enclosure solutions, so we bring unique understanding and experience to designing smart, cost-efficient network packaging solutions. It all starts with a diverse range of cabinets, racks and boxes for equipment, termination and server applications. Whether it s our modular PS enclosure system, versatile VarioRack or value-packed QuickRack line, Rittal has the network cabinet designed for any networking application. Wallmount cabinets such as our QuickBox or 2- and 3-Part boxes offer economical and highly functional solutions. And our line-up of racks feature BasicRacks, Data Racks and RiPatch, all which provide flexibility, strength and versatility for a wide range of applications and installations. But there s more to smart network solutions than just solid products. So Rittal provides literally hundreds of complementary products and accessories for flexible system design and cable management. Our wide range of cooling products like fans, air conditioners and fan trays protect your important network or computer 1

3 T ABLE OF CONTENTS Network Cabinets Overview... Pages 5-6 QuickRack... Pages 7-13 PS Series... Pages VarioRack... Pages Network Racks Overview... Pages BasicRack... Page 33 Data Rack... Page 34 RiPatch... Pages Wallmount Cabinets Overview... Pages QuickBox... Pages AE Series 2-Part... Pages EL Series 3-Part... Pages Server/Mass Storage Cabinets... Pages ISP Enclosures... Page 50 Seismic-Rated Cabinets... Pages Solutions For Education... Page 53 CMC (Computer Multi Control)... Pages Air Conditioners... Page 71 Blower Systems & Filter Fans... Page 72 Server Fan Assembly... Page 73 Technical Drawings... Pages Technical Appendix... Pages Additional Accessories... Page Climate Control Appendix... Page equipment from heat build-up. Rittal s new Computer Multi Control system allows you to remotely monitor your network cabinets for unwanted access, system performance, heat, fire and much more. And finally, our broad line of shelves, patch panels, lights, power strips and system accessories can be easily installed into Rittal rack systems. And if your application calls for a specific product solution, nobody supports you better than Rittal. From Internet Service and Education applications to Server and Seismic environments, Rittal s customer-driven market solutions provide the ideal solution. Plus, our networking products are backed by superior service and support. Our customer service team members provide quick and responsive technical and application advice, tailored to you. And our network solutions can be delivered to your project location within a quick turn-around from one of our nearby distributor locations or select from our QuickShip program that provides fast delivery of our most popular network cabinets and accessories. From products and accessories to market-driven solutions and additional tools, Rittal can provide the ideal product that meets your requirements. Get Connected with Rittal s unmatched solutions for networking. 2

4 Nobody Is Better Equipped To Help You With... SMART APPLICATIONS Data Rooms The main computer room of a company that may house multiple manufacturers of equipment including servers, hubs, routers as well as patch panel termination fields. Flexibility to hold multiple vendors and various types of equipment frequently are an issue. Rittal Applicable Products: VR server cabinets PS server cabinets VR network/termination cabinets PS network/termination cabinets RiPatch Data Rack BasicRack Climate control products Full line of Rittal accessories Wiring Closet/IDF A secondary location, normally one per floor that will house the terminations for that floor. This room may also hold electronic equipment. Security, aesthetics, climate control and functionality are commonly considered in the selection process. Rittal Applicable Products: QuickRack PS network/termination cabinets VR network/termination cabinets RiPatch Data Rack BasicRack EL 3-Part wallmount cabinets AE 2-Part wallmount cabinets QuickBox Climate control products Full line of Rittal accessories Factory Floor As more traditional networking applications find their way to the factory floor, there is a need for NEMA-rated enclosures (both freestanding and wallmount) to securely protect equipment. These enclosures can house termination gear as well as networking equipment. Rittal Applicable Products: PS network/termination cabinets EL 3-Part wallmount cabinets AE 2-Part wallmount cabinets Climate control products Full line of Rittal accessories Office Environment Often times there is a need for networking equipment to be developed out in an office environment. This can be in addition to or as a replacement to the Wiring Closet/IDF. Aesthetics, security and functionality play the major role in the decision process. Rittal Applicable Products: VR network/termination cabinets PS network/termination cabinets QuickRack EL 3-Part wallmount cabinets AE 2-Part wallmount cabinets QuickBox RiPatch Data Rack BasicRack Climate control products Full line of Rittal accessories Warehouse The warehouse is seeing more distributed processing with the increased deployment of more sophisticated inventory/package tracking systems. Physical protection, security and functionality are important considerations when choosing an enclosure. Rittal Applicable Products: PS network/termination cabinets VR network/termination cabinets EL 3-Part wallmount cabinets AE 2-Part wallmount cabinets QuickBox Climate control products Full line of Rittal accessories 3

5 Rittal s Networking Solutions Offer... POWERFUL PRODUCTS Cabinets Product Overview... Pages 5-6 QuickRack Basics... Pages 7-8 ValuePack... Page 9 PowerPack... Page 10 Accessories... Pages PS Basics... Pages PS Cabinets... Page 17 Accessories... Pages VR Basics... Pages VarioRack Cabinets... Page 27 Accessories... Pages Racks Product Overview... Pages BasicRacks... Page 33 Data Racks... Page 34 RiPatch... Pages Wallmount Boxes Product Overview... Pages QuickBox... Pages AE 2-Part... Pages EL 3-Part... Pages

6 Rittal s Comprehensive Family Of... NETWORK CABINETS B ASIC EQUIPMENT QuickRack A cost-effective versatile cabinet that combines superior styling with low prices. Design Four multiple roll-formed vertical profiles are screwed to a bottom and roof frame which can be done by one person. Simple construction with reasonable accessories available. Customers Contractors or installers that are price sensitive, as well as integrators, network managers, K-12 schools and government institutions. Applications An efficient and assembly-friendly solution for standard network applications. Used for passive or indoor network systems. Contractors or installers Light commercial Network equipment Termination equipment Environments Data centers MDF, IDF Wiring closets Replacement for open racks Office spaces Hot Buttons Cost-efficient Quick delivery Value solution Attractive design Easy to accessorize Cost QuickRack is the lowest cost data cabinet available from stock. V ERSATILE & STYLISH PS Pre-Configured The most versatile modular cabinet available in the market today. Available in NEMA 12 (standard) and NEMA 4 versions, the PS easily accommodates a variety of equipment. Design Completely welded, multiple roll-formed, steel frame ensures high stability. Standard system installation holes and extremely large assortments of accessories allow unlimited configurations. Customers End users or consultants that are interested in a cabinet that can be modified to hold various types of equipment. Applications For all situations that require sturdy and versatile enclosures with stability and increased protection requirements. Network equipment Factory floor Multiple types of equipment Environments NEMA 12 environments Data centers Warehouses MDF, IDF Hot Buttons Versatility in design Competitive cost Sturdy, yet attractive NEMA 12 standard, NEMA 4 Widest range of accessories Cost PS is the most cost-effective and versatile solution in the market today. S LEEK SHOWCASE VarioRack Rittal s VarioRack cabinet series is a highly styled equipment cabinet that reigns as the de facto server cabinet in the market. Design VarioRack cabinets accept all standard 19" components as well as Rittal's wide range of system accessories. The unique design allows for easy access to the system components from all sides during installation and service. Power strips can be installed inside rear frame posts that also serve as cable ducts. Customers End users or consultants that want either a showcase application or are looking for high end network equipment packaging. Applications Optimum styling of this unit provides a showcase for any office or mission critical network. Server environments High tech applications Showcase applications Multiple types of equipment Environments Data centers Server environments MDF, IDF Mission critical applications Hot Buttons Modern appearance and design Outstanding functionality Meets a wide range of network requirements Cost The VarioRack is a high-value stylized solution for network and server applications. 5

7 Quick Selection Guide QuickRack Accessories Part No. U inches mm Baying kit Power strips Roof fan tray Twin Captive M6 Monitor QR 8 outlet, casters nuts screws shelf H W D H W D 15 amp PS Pre-Configured Accessories Part No. U inches mm Fixed vented Power strip Roof blower Caster kit Telescopic DK H W D H W D shelf 6 outlet, 15 amp system slide VarioRack Accessories Part No. U inches mm Fixed vented Telescopic Power strip Roofmounted Twin casters DK H W D H W D shelf slide fan tray * * * Note: VR shelves require installation kit (Part No or ) on 24" (W) VR cabinets with VR style 19" rails. Comparison Guide APPLICATIONS Equipment Termination Telecommunication QUICKRACK BASIC EQUIPMENT PS PRE-CONFIGURED VERSATILE & STYLISH Seismic/Zone 4 EMC DIFFERENTIATION Price Modularity Attractiveness Accessory Range Climate Control Fans Fans, Heat Exchangers, A/C Fans Special Paint Extensive Modifications KEY = Highly recommended = Recommended = Not recommended VARIORACK SLEEK SHOWCASE 6

8 QUICKRACK BASICS 1 The QuickRack offers a very simple and cost-effective solution for many electronic and network applications. First, it makes depth-variable installation of 19" components possible. And because of its 2 innovative design, QuickRack can be accessorized in a short time. Cable entry is via the open bottom frame or through a brush insert in the roof panel. Check out the basics of this innovative electronic and networking cabinet. 1 CABLE MANAGEMENT The roofs of all QuickRack enclosures feature a standard cable entry panel with brush insert. Cable bundles are routed into the QuickRack through an open bottom panel. 5 Removable base panels allow cable entry and exit from all directions. The combination rail ensures correct cable management. This rail allows two kinds of cable attachment: with cable ties to the top and bottom sprockets of the rail, or with cable clamps to the C-rail section of the combination rail. 2 CLIMATE CONTROL 4 Blank panels in the roof panel can be easily removed and replaced with fan inserts. 7

9 3 D ESIGN DETAILS Smart Solutions Two widths, three heights, two depths. High stability through multiple roll-formed vertical members. Large enclosure with cable-entry roof panel. Active ventilation possible by installing fans in the roof. The multiple roll-formed upright members provide high stability. Simple, elegant frame profiles. Four leveling feet are included with each QuickRack to help compensate for uneven floors. 4 D OORS/S IDEWALLS The front door has a sheet steel frame with a glass viewing window. Door hinging can be easily changed from left to right and vice versa. Ventilation slots in the sheet steel rear door promote air circulation within the enclosure. Viewing doors and sheet steel doors feature handles with security locks. Sidewalls have similar locks. Rows of QuickRacks can be easily connected with each other with connecting kits. Just hang the sidewalls in place and turn the lock it can t go any faster. 3 5 C OMPONENT INSTALLATION All QuickRacks feature a 19" mounting surface. Depth bars make it easy to depth-adjust both the rear and front mounting surfaces. Support rails can be hung and secured in the installation holes of 19" rails. Installation holes in the 19" rails and the frame offer ample opportunities to mount component shelves, fixed or on telescopic slides. Larger shelves can be mounted to brackets by removing the 19" rails. Power strips can be fastened to the vertical frame members of the QuickRack with an adapter bracket. 8

10 Value-Packed Network Cabinets With... QUICKRACK VALUEPACK Rittal offers a variety of QuickRack cabinets in the most popular configurations for the networking market. Heights range from 24 to 47U and include a choice of widths and depths. These standard cabinets come packed full of features that make the cabinet an easy to work with solution for many network applications. For quick availability, easy transportation and innovative design, look no further than the QuickRack ValuePack. C ONFIGURATION Front safety glass viewing door with lock insert Vented rear steel door with lock insert Full height 19" DK rails, front and rear Cable entry roof with brush insert Two sets of horizontal rail supports Leveling feet Available with or without sidewalls 50 captive nuts 100 mounting screws RAL 7035 (light grey) QuickRack ValuePack Accessories Part No. QR Part No. QR Cabinet Cabinet 19" Cable Cable collecting rails Monitor with without U width depth rackmount base Across Across shelf sidewalls sidewalls (inches) (inches) shelf* width depth 48" cabinets " cabinets " cabinets Note: multiple cabinets can be bayed together using Part No Remember to order one cabinet with sidewalls per row of cabinets and the rest without. * Fixed shelves that mount to horizontal rail supports also available. Cabinets come standard with DK style rails. Diagram of rails found on page 84. Note: please reference page 74 for technical drawings. 9

11 Get The Rittal Power From... QUICKRACK POWERPACK For a more advanced network cabinet offering, get the QuickRack PowerPack. The PowerPack offering combines the value-packed QuickRack cabinet with two exciting features: an eight outlet power strip and a fan tray for air movement within the cabinet. Add to that the advantages of the cabinet itself costefficiency, accessibility and easy transition of applications and you ll get the power from QuickRack. C ONFIGURATION Front safety glass viewing door with lock insert Vented rear steel door with lock insert Full height 19" DK rails, front and rear Two sets of horizontal rail supports Roof with fan tray (two fans on 24"W, three fans on 32"W), 9' cord/plug 8 outlet, 15 amp power outlet strip Leveling feet Available with or without sidewalls 50 captive nuts 100 mounting screws RAL 7035 (light grey) QuickRack PowerPack Accessories Part No. QR Part No. QR Cabinet Cabinet 19" Cable Cable collecting rails Monitor with without U width depth rackmount base Across Across shelf sidewalls sidewalls (inches) (inches) shelf* width depth 48" cabinets " cabinets " cabinets Note: multiple cabinets can be bayed together using Part No Remember to order one cabinet with sidewalls per row of cabinets and the rest without. * Fixed shelves that mount to horizontal rail supports also available. Cabinets come standard with DK style rails. Diagram of rails found on page 84. Note: please reference page 74 for technical drawings. 10

12 QuickRack Accessories Sidewalls Sidewalls feature a quick-lock with security insert. They are simply hung in place and locked and always offer immediate side access to inside components. Material: sheet steel Color: light grey (RAL 7035) Configuration: 2 sidewalls with quick-lock security insert Packs of 2 Enclosure Enclosure Part No. height depth DK 47.24" 23.62"/600mm mm 31.50"/800mm " 23.62"/600mm mm 31.50"/800mm " 23.62"/600mm mm 31.50"/800mm Base The base provides 4"/100mm additional height for cable management. Cable entry from all four sides through removable panels. Leveling feet can compensate for unevenness of floor. Material: sheet steel Color: light grey (RAL 7035) Configuration: base, includes installation hardware For enclosure Part No. Frame Frame DK width depth 23.62" 23.62" 600mm mm 31.50" 800mm " 31.50" 600mm mm 31.50" 800mm Vented Component Shelves Weight capability: 110 lbs static capacity Color: light grey (RAL 7035) Configuration: 1 shelf with installation hardware Shelf width x depth Part Tele- Handles No. DK scopic inches mm rails x x x x x x 500* * Only for 32 /800mm deep cabinets. Component shelves for fixed or extendable mounting on enclosure frame For frame width Shelf WxD Part No. DK inches mm x x "/600 mm x x x x * x x "/800 mm x x x x * * Only for 32 /800mm deep cabinets. Installation kit for component shelves Mounting a component shelf directly to the enclosure frame requires an installation kit that matches the enclosure depth. This makes it possible to install 18.54"/26.42" (471/671mm) wide component shelves in 23.62"/31.50" (600/800 mm) wide enclosure frames. Material: sheet steel, zinc-coated, chromated Configuration: 2 mounting angles, installation hardware Enclosure depth Packs of Part No. DK 24" 600 mm " 800 mm

13 19" Component Shelves 2U Can be installed: In enclosure between 19" rails In swing frames with special 19" angles In vented component shelves with 19" rail mounting Material: sheet steel Color: light grey (RAL 7035) For installation in fixed position or on telescopic slides mm inches Part No. DK W D W D Vented component shelves (with 19" rail mounting) mm inches Part No. DK W D W D Fan Trays Fan trays mount into roof cut-outs for increased air movement. 100cfm unimpeded airflow for each fan, 9' cord with plug. Cabinet width No. of fans Part No. SK 23.62"/600mm 2=200cfm total 31.50"/800mm 3=300cfm total Support Rails Rails hang in sides of 19" rails to support heavy 19" rack-mounted components. Material: sheet steel, zinc-coated, chromated Configuration: 2 slide rails Length Packs of Part No. DK 5.98"/152 mm * 10.28"/261 mm "/361 mm "/461 mm *Can only be mounted to front or rear rails. 19 Rails Rails can be depth-variable installed on depth bars for easy mounting of 19" components. Material: sheet steel, zinc-coated, chromated Configuration: 2 rails, includes installation hardware U SU Enclosure Part No. DK height "/1200mm "/2000mm "/2200mm

14 QuickRack Accessories Combination Cable Collecting Rails These rails make it possible to fasten cables with cable clamps or cable ties and also allow equipotential bonding between the cable shield and ground bus. Material: sheet steel Configuration: combination rail, installation hardware For Mounting In Enclosure Depth Frame Packs of Part No. depth DK 23.62" 600mm " 800mm For Mounting In Enclosure Width Frame Packs of Part No. width DK 23.62" 600mm " 800mm Baying Kit For simple and easy connecting of a row of network cabinets. Mounts on upright frame posts of adjoining cabinets. Material: sheet steel Color: light grey (RAL 7035) Configuration: connecting kit, includes installation hardware Packs of Part No. DK 1 set Power Strips Kit 8 outlet, 15 amp power outlet strip. Includes adaptor kit to mount strips on vertical frame posts of cabinets. Configuration: adaptor kit, includes installation hardware Packs of Part No. DK 1 set FPO Twin Casters Casters provide mobility on even floors. Load capacity/twin caster: 200 lbs/80 kg Load capacity/enclosure: max. 530 lbs/240 kg Configuration: 4 twin casters, installation hardware Packs of Part No. FR Additional Accessories Description Part No. EL M6 screws Captive nuts

15 Notes 14

16 PS MODULAR NETWORK CABINETS Rittal's patented, modular PS 4000 "Perfect System" offers expert solutions for network applications, with the largest amount of usable space installation surfaces versatility and labor-savings quick assembly. Other advantages include flexible component mounting options, high NEMA industrial protection ratings, large load capacities and an extensive line of practical system accessories. PS 4000 based network cabinets are available in a wide range of sizes and configurations DESIGN ELEMENTS Sturdy PS 4000 network cabinets feature Rittal's patented 9-fold, rollformed frame components. Its strong frame design ensures high stability and load capacity. 4 Installation holes are round and square, spaced at.98"/25mm intervals and provide unlimited mounting options. Labyrinth design and foamed-ongaskets ensure high NEMA industrial protection ratings. 2 CABLE MANAGEMENT 2 Cable entry is easy through multi-part bottom panel. Cable guide rings provide orderly cable management behind patch panels. 15

17 3 DOORS AND SIDEWALLS 4 MOUNTING SURFACES PS cabinets feature a polycarbonate viewing door. Lock inserts of the Ergoform-S handle can be replaced with standard inserts and security locks. 180 hinges provide unimpeded access to installed components. Door hinging of front and rear doors - standard on right - can easily be changed to left. Mixed component installation - 19" components in top area and utilization of full cabinet space in bottom area. Depth variability allows mounting surfaces to be installed at any depth in.98"/25mm intervals. 3 Sidewalls are easy to install... just hang and secure by turning lock. Quick connecting wedges for on-site connecting of network cabinets. Interconnecting kit offers a concealed but sturdy way of connecting suites of network cabinets. Heavy components can be mounted on two 19" mounting surfaces - front/rear - and supported with system chassis. 5 COMPONENT INSTALLATION Options include lockable drawers in a variety of types and sizes for most connector systems. Splice boxes, fiber optic distributors and a comprehensive variety of fiber optic accessories are available. Component shelves are available in two versions: 1) for mounting on 19" rails 2) for mounting on enclosure frames. 6 CLIMATE CONTROL Vented roof with cable entry can replace the standard roof. Roofmount blowers can be retrofitted in PS network cabinets. Vented cable base for air flow from below. 16

18 Modular NEMA-Rated Network Cabinets... PS PERFECT SYSTEM ENCLOSURES The Rittal freestanding NEMA 12 network cabinets are based on Rittal s patented PS Series technology, featuring a standard installation hole system for maximum space utilization. The cabinet s rugged construction offers high stability as well as high-load bearing capacity. Components are visible through the viewing door and are fully accessible from all sides through front/rear doors and removable sidewalls. Rittal s PS cabinets are available in our most popular sizes with standard accessories. C ONFIGURATION Smoked polycarbonate front viewing door Steel rear door Removable locking sidewalls Ergoform-S handles with pushbutton lock inserts, front and rear Removable solid roof Bottom cable entry panels 19" DK-PS rails, front and rear 1 set of system chassis Mounting brackets, top and bottom 50 captive nuts 100 mounting screws RAL 7032 (pebble grey) or RAL 9005 (black) Grey PS Cabinets Accessories Part No. DK Part No. DK Height Width Depth Cable Raised Roofmount 19" rack Telescopic 8 outlet frame with without inches/u inches inches entry roof vented blower mounted slides mounted sidewalls sidewalls roof shelf power strip "/24U "/36U "/42U "/47U Note: multiple cabinets can be bayed together using Part No , or Remember to order one cabinet with sidewalls per row of cabinets and the rest without. Cabinets come standard with DK style rails. Diagram of rails found on page Black PS Cabinets Accessories Part No. Dimensions U Perforated mm Shelf mm Cable mm Roof mm Raised mm 8 outlet DK mm inches door entry roof blower roof 15/20 Amp H W D H W D power strip x x x x x x x x x x x x x x x x Note: please reference page 75 for technical drawings.

19 PS Accessories Vented Component Shelves (With 19" Rail Mounting) Can be installed in two ways 1. In fixed position, or 2. Fully extendable on telescopic slides. Each enclosure type requires its own specific installation kit corresponding with its width and depth. Load capacity: 110 lbs/50 kg Dimensions Part No. DK inches mm 16" x 12" 409 x " x 16" 409 x " x 20" 409 x " x 24" 409 x Configuration: Component shelf including installation hardware Sheet steel Painted light grey (RAL 7035) or pebble grey (RAL 7032) Solid or slotted to prevent heat build-up (slots accommodate DK positioning studs) * Only for 800mm deep enclosures. ** Use suffix.035 when ordering light grey (RAL 7035) component shelves. *** Installation kits not included or for standard shelves or for heavy duty shelves. Refer to shelf selection guide, pages Component Shelves (Without 19" Rail Mounting) For installation in enclosures that do not have 19" rails. Depth of shelf should not exceed enclosure depth minus (-) 3.94 /100mm. Available in two versions: max. load capacity: 110 lbs/50 kg max. load capacity: 220 lbs/100 kg Can be installed in two ways: 1. Permanently fixed, or 2. Fully extendable on optional telescopic slides. Color: pebble grey (RAL 7032) or light grey (RAL 7035**) Configuration: Component shelf including installation hardware*** Sheet steel, 16/14 ga (1.5"/2mm) Solid or slotted to prevent heat build-up (slots accommodate DK positioning studs) Can be mounted and adjusted in 0.98"/ 25mm increments Mounting holes for handle 220 lbs/100 kg version is 1.77"/45mm high Vented component shelves for fixed or extendable mounting on enclosure frame Max. load Shelf W x D 110 lbs/50 kg 220 lbs/100 kg For encl. Part No. DK Part No. DK width inches mm 24" x x mm x x x x * * 32" x x mm x x x x * * Installation Kit For 110 lbs/50 kg Component Shelves Material: sheet steel, zinc-coated, chromated Configuration: system bars, stop/spacer bracket and installation hardware Fixed or on telescopic slides For Packs of Part No. DK enclosure depth 24"/600mm 1 set "/800mm 1 set " Component Shelf 2U (For Fixed Installation) A convenient solution for when only one 19" mounting surface is available. Cannot be retrofitted with telescopic slides. Static load capacity: 55 lbs/25 kg Material: sheet steel Color: pebble grey (RAL 7032) or light grey (RAL 7035) Width Part No. DK Part No. DK x depth RAL 7032 RAL " x 11.31"/ mm x 300mm 15.35" x 16"/ mm x 400mm 18

20 Handle For Component Shelves Handles are die-cast zinc, painted. Includes installation hardware. All component shelves have mounting holes for handles. Packs of Part No. VS Telescopic Slides For Component Shelves Sides are fully extendable, and can also be easily retrofitted to convert fixed shelf into sliding shelf. Available in two versions: max. load capacity: 110 lbs/50 kg max. load capacity: 220 lbs/100 kg Technical description: Installation adjustable in.98"/25mm increments 2-stage extension Material: sheet steel, zinc-coated, chromated For shelf Packs Part No. DK depth of max. load capacity 110 lbs 50 kg 220 lbs 100 kg 12"/300mm 1 set "/400mm 1 set "/500mm 1 set "/600mm 1 set " Keyboard Drawer 2U, For All Enclosures With A 19 Mounting Surface Fits desktop, wallmount and freestanding enclosures with a 19" mounting surface. For up to 16.9"/430mm wide keyboards. Technical description: lockable keyboard drawer with handles, fold-down front, pull-out mouse pad, practical cable entry and strain relief Material: sheet steel with aluminum front Color: pebble grey (RAL 7032) or light grey (RAL 7035) Keyboard Part No. DK drawer RAL 7032 RAL Installation depth: 390mm Support Rails For DK-PS Top support heavy 19" components in network cabinets with two 19" mounting surfaces. Material: sheet steel, zinc-coated, chromated Configuration: 2 support rails, installation hardware Length inst. Hole Packs Part No. mm centers of DK mm 152* Front and rear 19" DK-PS rails required * Can only be mounted to front or rear 19" DK-PS rails. Not suitable for PS servers. Ventilated Roof Replaces standard roof and has ventilation slots to promote heat removal. The ventilated roof can be used in conjunction with a roof blower. Not suitable when enclosure is lifted from top. Material: sheet steel Color: pebble grey (RAL 7032) Configuration: ventilated roof with spacers and installation hardware For enclosure W x D Packs Part No. inches mm of DK 24 x x set x x set x x set

21 Roof Spacers Roof spacers are available in three different heights to lift roof for ventilation or facilitate cable entry. Not suitable when enclosure is lifted from top. Height Packs of Part No. SZ.2"/5mm "/10mm "/20mm Cable Entry Roof Panel The cable entry roof panel replaces the standard roof panel. One stationary and one adjustable panel with foam gasket allow easy cable entry. Material: sheet steel Color: pebble grey (RAL 7032) For enclosure W x D Packs Part No. inches mm of DK 24 x x set x x set x x set Plinths And Cable Bases Plinths and cable bases are available in 4" and 8" (100 and 200mm) heights to allow more clearance and easy cable entry. The rear panels of 8"/200mm high cable bases consist of two panels that can be removed individually, while the side panels can be laid flat to allow interconnecting and easy cable routing from enclosure to enclosure. System installation holes in these side panels facilitate the mounting of cable collecting rails. Special hardware (included) ensures fast and easy mounting only one screw is needed to fasten a side panel to a corner piece. The bases can be easily mounted to enclosures with cage nuts and spring washers. For enclosure Part No. SO W x D 4" plinth/ 8" base/ 100mm 200mm 24" x 24" 600 x 600mm " x 32" 600 x 800mm " x 32" 800 x 800mm Material: sheet steel Color: dark grey (RAL 7022) Configuration: 4 corner pieces with removable front, rear and side panels Installation Brackets Facilitate installation of 19" rails in DK-PS cabinets. Material: sheet steel Color: zinc-coated, chromated or grey (RAL 7032/RAL 7035*) Cabinet 19" Part No. DK width installation painted zinc-coat mm level RAL 7032 chromated 600 center on side center Packs of 2 * Use suffix.035 for ordering version painted light grey in RAL Mounting Rail For use with 32" wide (800mm) PS cabinets only. Bracket to move 19 rails to 23 or 24 width. Material: sheet steel Finish: zinc-coated, chromated Packs of Part No. DK

22 Caster Kit Casters help simple movement on even floors. Easy to install. Features thumbscrew brake mechanism. Kit includes adjustable wrench. Load capacity/caster: 500 lbs/227 kg Type of thread: M12 Kit includes Part No. PS 4 casters /1 wrench Leveling Feet With Swivel Base Compensate for uneven floors and can be mounted on enclosure or on base. Length of thread: 2"/51 mm Load capacity/leveling foot: 500 lbs/227 kg Type of thread: M12 For Packs of Part No. DK DK-PS System Chassis With Mounting Flanges.9" x 2.9" (23 x 73mm) for intermediate mounting of 19" rails or T-slot rails, simply hook in cabinet frame and secure. Cabinet depth Packs of Part No. PS 24"/600mm "/800mm "/900mm "/1000mm Cable Routing Duct Cable routing ducts make cable routing on the side of the cabinet possible. The cable routing duct is mounted on the 19" rails in a 31.50"/800mm wide PS network cabinet. The removable front panel is secured with quicklocks to provide simple and easy access. Material: sheet steel Color: light grey (RAL 7035) For cabinet Part No. height DK 64"/1600mm "/1800mm "/2000mm "/2200mm

23 Roofmount Blower System Air displace- Dimensions Noise Part No. ment cfm at mm inches level SK For 600 and 800mm wide PS cabinets. free delivery H W D H W D dba Was especially designed for applications that require forced air cooling. The blower systems are mounted to the enclosure frame and can be used with either a raised roof or ventilated roof. 110V Material: sheet steel Color: silk grey (RAL 7044) Configuration: includes mounting hardware, " spacer bolt for raising standard roof and 10' cord/plug Refer to pg. 72 for additional information. Air Conditioners Mini air conditioners Especially developed for small enclosures but can also be used in large enclosures with low heat dissipating requirements. They are available in compact roofmount and powerful wallmount versions. Medium range wallmount air conditioners These medium capacity Rittal air conditioners are in use worldwide and stand out through high dependability, flexible installation options, optimum ease of operation and high safety standards. Wallmount air conditioners Today's industrial design requires that equal attention be given to functionality, ergonomics and aesthetics. Rittal's multi-functional wallmount air conditioners fully meet these requirements through their user friendliness, microcontroller technology and ease of installation because of their two-piece chassis construction. Rated Dimensions Useful cooling capacity Rated Current Product/ voltage (H x W x D) Qk per DIN F Part No. SK V/Hz ambient 95 F temp. setting 115/50/ " x 15.75" x 9.76" 2325 BTU / 2400 BTU 5.1/6.0A Mini wallmount 635mm x 400mm x 248mm 680 W / 700 W air conditioner / /50/ " x 15.75" x 9.05" 2800 BTU / 3300 BTU 6.5/7.6A Wallmount air conditioner/ 950mm x 400mm x 230mm 825 W / 960 W /50/ " x 15.75" x 10.24" 4775 BTU / 4950 BTU 11.5/20.0A Wallmount air conditioner/ 1265mm x 400mm x 260mm 1400 W / 1450 W /50/ " x 16.00" x 12.00" 6895 BTU / 7575 BTU 13.8/17.8 A Wallmount air conditioner/ 1580mm x 430mm x 290mm 2000 W / 2220 W Note: see pages for help in determining your specific climate control needs. Roof Fan Mounts easily into any enclosure roof. Requires round cutout. Material/finish: Fan housing of black painted sheet steel with chrome plated finger guards. Configuration: Fan assembly; 10' power cord with plug; grounding strap; installation hardware, 2 finger guards. Protection Noise Rated Air Dimensions Rated Part No. SK rating level current displacement in mm voltage* H W D NEMA 1 50 dba 0.4 A 500 cfm / * 230 V available Roof Fan Tray Depth/ Height Adjustable perforated roof, a raised roof or 2 SK exhaust filters. Material: sheet steel For 600 and 800mm wide PS cabinets Finish: E-coat primer; powder painted designed for applications that require forced pebble grey (RAL 7044). air cooling, mounts in side of enclosures Configuration: Fan assembly; 10' power frame or on system bars anywhere in cord with plug; grounding strap; installation enclosure. Can be used with either a hardware. Protection Noise Rated Air Dimensions Rated Connection Enclosure Part No. rating level current displace- in mm voltage width SK ment H W D NEMA 1 48 dba 0.4 A 300cfm /60 10' cord 600mm NEMA 1 48 dba 0.4 A 300cfm /60 10' cord 800mm

24 Cable Collecting Strip The cable collecting strip is mounted directly to patch panel with bolts to provide strain relief for wiring to and from patch panels. Available with and without spring clamps for fastening and grounding of the cable shield. Material: 14 ga/2mm sheet steel, chromated Configuration: 1 cable collecting strip and installation hardware Version Part No. DK Without cable shield grounding With spring clamps for cable shield grounding Cable Guide Rings For flexible, system-compatible cable routing on system strips, enclosures or at the sides on 482.6mm (19") mounting angles. Material: sheet steel, zinc-plated, passivated Configuration: includes locating plate and fixing accessories Dimensions Packs Part No. DK mm of 120 x x x " Routing Panel 1U 5 cable guides to route patch cables horizontally. Material panel: sheet steel Material cable guides: polyamide Color: light grey (RAL 7035) U Part No. DK Interconnecting Kit For DK-PS Hexagonal spacers with bolts ensure a sturdy, simple and invisible connection between adjoining network cabinets. Material: sheet steel, zinc-coated, chromated Packs of Part No. PS Velcro Cable Straps Velcro cable straps make cable management even easier because access to cables is unlimited and cables can be added or removed at will. The straps can be attached to cable collecting rails, C-rails, system rails or the enclosure frame. They can also be screwed to the standard installation holes in the enclosure frame with SZ BZ 5.5 x 13mm screws (packs of 300). Color: black Width Length Max. Packs Part No. cable of DK Ø.62" 5.12" 1.18" mm 130mm 30mm.62" 7.87" 1.97" mm 200mm 50mm.62" 11.81" 3.54" mm 300mm 90mm Cable Ties For The PS Quick-Assembly System Provide a quick solution to the problem of attaching small cable harnesses onto a frame. Simple clip into the standard installation holes. Length Packs of Part No. SZ 6"/150mm

25 115V Power Strips For USA/ Canada Complete with: Illuminated ON/OFF rocker switch Circuit breaker 6-foot power cord with plug 19" Rackmount Power Strips Attach to any 19" rails for convenient power source to components. Illuminated ON/OFF power switch High quality industrial strength 6-foot power cord with plug Rackmount Power Strips Number of outlets Amp Surge Approvals Color Part No /20 protection CSA UL DK 6 (3 duplex) - 15A X X X pebble grey (RAL 7032) (3 duplex) - 15A X X X light grey (RAL 7035) (3 duplex) - 15A X X light grey (RAL 7035) (3 duplex) - 20A X X light grey (RAL 7035) (3 duplex) - 15A X X X X light grey (RAL 7035) Frame Mounted Power Strips These strips have two clip-in brackets for mounting to any frame member of PS enclosures or system chassis that are installed in any Rittal enclosure. Illuminated ON/OFF power switch High quality industrial strength 6-foot power cord with plug Frame Mounted Power Strips Number of outlets Amp Surge Approvals Color Part No /20 protection CSA UL DK 8-15A X X X silk grey (RAL 7044) A X X silk grey (RAL 7044) (4 duplex) - 20A X X silk grey (RAL 7044) A X X X X silk grey (RAL 7044) A X X X silk grey (RAL 7044) A X X silk grey (RAL 7044) A X X X X silk grey (RAL 7044) (8 duplex) X X silk grey (RAL 7044) A X X X silk grey (RAL 7044) A X X silk grey (RAL 7044) (12 duplex) - 20A X X silk grey (RAL 7044) A X X X X silk grey (RAL 7044) For additional power strips, refer to chart on pages Installation Bolts M6 x 16 mm For captive nuts, 19" rackmount components, and blanking panels. Plastic washers included. Type Packs of Part No. EL Slotted bolt Phillips bolt Captive Nuts For attaching 19" rackmount components and blanking panels to 19" rails. With conductive contact between the components and the enclosure. Without conductive contact between the components and the enclosure. Captive nut Thread Packs of Part No. EL with contact M without M contact 10/

26 VARIORACK BASICS 1 Network cabinets based on the Rittal VarioRack System combine optimum functionality and efficiency with outstanding design... the perfect answer to a variety of network requirements in a range of environments - both office, lab and data center. In fact, the Rittal VarioRack is a highly styled equipment cabinet that reigns as the defacto server cabinet in the market. 5 1 DESIGN ELEMENTS Aesthetic design makes these cabinets ideal for both office and lab applications. Power strips can be built into the rear frame posts. 4 Rittal PS system accessories can be used because VarioRack features the standard Rittal installation hole pattern. End users will find the VR is an ideal solution for showcase applications. 2 DOORS/SIDEWALLS User-friendly innovative design makes removing or hanging doors literally a "snap." Sidewalls with quick-locks... just hang in place and secure. Ergoform-S handle system, with many different types of inserts, features an ergonomic design and easy maneuverability. 3 25

27 3 BOTTOM/BASES Standard 2"/50mm base, with leveling feet can be replaced with 4"/100mm or 8"/200mm cable bases. Twin casters for VarioRack allow additional base options. 3-part bottom panel standard in all network cabinets - can be infinitely adjusted for flexible cable entry options. 4 COMPONENT INSTALLATION 2 2U or 3U drawers provide additional storage options. Keyboard drawer with pull-out mouse pad. 19" rails are adjustable for both depth and width in 25mm increments. Component shelves can be installed on telescopic slides or in a fixed position. Slide/support rails support heavy 19" network components. 5 CLIMATE CONTROL Fan trays for installation in the roof frame provide for effective heat removal. Vented rear door is standard in VR network cabinets. Roof panel with or without vent slots allows the user to customize the VarioRack for the needed ventilation. 26

28 Stylish, Pre-Configured Network Solutions... VARIORACK CABINETS Rittal s VR Series freestanding network cabinets combine modern design and appearance with outstanding functionality to answer a variety of network requirements. The cabinets accept all standard 19" components as well as Rittal s wide range of system accessories. The unique design allows for easy access to the system s components from all sides during installation and service. Power strips can be installed in rear frame posts that also serve as cable ducts. The Rittal VR Series offers a unique enclosure system for any networking application. C ONFIGURATION Smoked acrylic front viewing door Vented rear steel door Removable sidewalls Solid roof Bottom cable entry panels Ergoform-S handle with pushbutton lock insert front/rear Integrated leveling feet 32" wide VRs: 19" DK-PS rails front/rear 24" wide VRs: 19" VR rails front/rear 50 captive nuts 100 mounting screws RAL 7035 (light grey) VarioRack Cabinets Accessories Part No. Part No. U Dimensions 4" base Power 19" rack Telescopic Installation Casters Roofmount DK with DK without inches/mm outlet mounted slides kits fan tray sidewalls sidewalls H W D strip shelf " 24" 34" or " 32" 34" Not necessary " 24" 34" or " 32" 34" Not necessary 27 Note: please reference page 76 for technical drawings.

29 VarioRack Accessories 19" Component Shelves, Vented These shelves are installed between 19" rails - in fixed position or on telescopic slides. Load capacity: 110 lbs/50 kg Color: Light grey (RAL 7035) Note: sets of rails (front and rear) are required for shelf mounting. For Installation In Fixed Position Or On Telescopic Slides Dimensions Mounting Part No. Installation kits* Telescopic slides mm inches distance mm DK for 19" rail mounting W D W D (110 lbs) or / or /350/ or * Necessary for 24" wide VRs. Handle for shelf may also be ordered (Part No ). Frame Mounted Heavy Duty VR Shelves - Fixed Installation WIthout 19" Rails Part No. Description mm Enclosure Dimension mm System Chassis Also needed x x self-tapping screws x x self-tapping screws x x self-tapping screws x x self-tapping screws * x x self-tapping screws The above shelves screw into frame and system chassis for additional support. * Mounts directly on top of system chassis between 19" rails. 19" Support Rails These rails can be installed in all network cabinets that have two 19" mounting surfaces. Server or active network components can easily be inserted in any type of network cabinet. The length of the support rails is infinitely adjustable between 22" - 34"/ mm. Support rails Packs Part No. DK mm of Material: sheet steel, zinc-coated, chromated Configuration: 2 infinitely adjustable support rails, installation hardware only for 24" wide VRs. Support Rails For VRs Support heavy 19" components in network cabinets with two 19" mounting surfaces. Material: sheet steel, zinc-coated, chromated Configuration: 2 support rails, installation hardware 24"/600mm Wide VRs (mounts in VR frame) Length Fits VR depth Packs Part No. mm mm of DK * ** * Height adjustable. ** One set of rails only. 32"/800mm Wide VRs (mounts in rear part of 19" rail) Length Inst. hole centers Packs Part No. mm mm of DK 152* * Can only be mounted to front or rear 19" VR rails. Twin Casters Makes it easy to change location. Can be installed together with leveling feet. Load capacity: 200 lbs/90 kg per caster Packs of Part No. VR

30 115V Power Strips For USA/ Canada Complete with: Illuminated ON/OFF rocker switch Circuit breaker 6-foot power cord with plug 19" Rackmount Power Strips Attach to any 19" rails for convenient power source to components. Illuminated ON/OFF power switch High quality industrial strength 6-foot power cord with plug Number of outlets Amp 19" Rackmount Approval Color Part No /20 power strips CSA UL DK 6 (3 duplex) - 15A X X X pebble grey (RAL 7032) (3 duplex) - 15A X X X light grey (RAL 7035) (3 duplex) - 15A X X light grey (RAL 7035) (3 duplex) - 20A X X light grey (RAL 7035) (3 duplex) - 15A X X X X light grey (RAL 7035) Frame Mounted Power Strips These strips have two clip-in brackets for mounting to any frame member of enclosures or system chassis that are installed in any Rittal enclosure. Illuminated ON/OFF power switch High quality industrial strength 6-foot power cord with plug Frame Mounted Power Strips Number of outlets Amp Surge Approvals Color Part No /20 protection UL CSA DK 6 X X X silk grey (RAL 7044) For addtional power strips, refer to charts on pages Cable Base Offers ideal cable entry options through removable side panels. Also accepts leveling feet and casters (VR ). These bases replace standard base of VR cabinets. Material: sheet steel Color: pebble grey (RAL 7032) Configuration: 4 corner pieces, 4 side trim panels (for 4"/100mm bases) or 8 side trim panels (for 8"/200mm bases) 24 Wide VR Cabinets Height Enclosure Enclosure Part No. mm width depth VR mm mm Wide VR Cabinets Height Enclosure Enclosure Part No. mm width depth DK mm mm Interconnecting Frames Connects several VarioRack network cabinets. Material: natural aluminum/sheet steel, painted Color: 2 horizontal aluminum profiles, 2 vertical aluminum profiles, installation hardware For Height Depth Part No. enclosure VR "/ 34"/ mm 850mm "/ 34"/ mm 850mm

31 Cable Guide Rings For flexible, system-compatible cable routing on system strips, enclosures or at the sides on 482.6mm (19 ) mounting angles. Material: sheet steel, zinc-plated, passivated Configuration: locating plate and fixing accessories Dimensions Packs Part No. DK mm of 120 x x x Cable Guide Rings, Plastic They enhance flexible cable management. Infinitely adjustable installation on 19" rails, distributors, system rails of cross connect enclosures, patch panels, Rittal Data Racks, as well as all components with the standard PS (.98"/25mm) installation hole pattern. 0 and 90 installation is possible with included locking bracket. Material: polyamide Color: light grey (RAL 7035) Configuration: includes locking bracket and installation hardware Dimensions Packs Part No. DK mm of 70 x * 105 x * Can also be used for 1U high patch panels 19" Keyboard Drawer 2U, For All Enclosures With A 19" Mounting Surface Fits desktop, wallmount and freestanding enclosures with a 19" mounting surface. For up to 16.9"/430mm wide keyboards. Technical description: lockable keyboard drawer with handles, fold-down front, pull-out mouse pad, practical cable entry and strain relief Material: sheet steel with aluminum front Color: pebble grey (RAL 7032) or light grey (RAL 7035) Keyboard Part No. DK drawer RAL 7032 RAL Installation depth: 390mm Cable Collecting Strip Strip is mounted directly to patch panel with bolts to provide strain relief for wiring to and from patch panels. Available with and without spring clamps for fastening and grounding of the cable shield. Material: 14 ga/2mm sheet steel, chromated Configuration: 1 cable collecting strip and installation hardware Version Part No. DK Without cable shield grounding With spring clamps for cable shield grounding Roofmount Fan Tray Installs into the upper frame of Rittal VarioRack Series enclosures, without loss of usable installation space. Fully wired, with 8 power cord and plug. Technical Data: Rated voltage: 115V, 50/60 Hz Rated current: 19/18 W per fan Noise level: 46 dba Motor speed: 2650/3100 rpm Air displacement per fan: 110cfm/170 m 3 /h (unimpeded air flow) For enclosure Number Part No. width mm of fans VR Ambient temperature: +14 F to +131 F/ -10 C to +55 C Configuration: fan housing; fans; power cord; plug; installation hardware Additional fans can be installed, Part No

32 Rittal s Comprehensive Family Of... NETWORK RACK SOLUTIONS STANDARD & ECONOMICAL BasicRack A complete low-cost, high-quality basic equipment management system. Design Six web channel holes per side allow multiple racks to be bayed together. The BasicRack is made of high strength aluminum extrusion combined with high strength roll-formed thread mounting holes. The rack's base can be bolted to floor for greater stability. The rack has a 5/8" - 5/8" x 1/2" hole pattern. Customers Contractors, educational institutions and IDFs. Applications A complete low-cost, high quality basic equipment management system. Termination equipment Monitoring equipment Other 19" rackmount applications Environments IDFs Data rooms MIS applications Light duty equipment Hot Buttons Economical solution Basic design Easy access to equipment Self-support rack, bolt-down base Stand alone or interconnected High strength aluminum extrusions Cost Designed for price conscious, high-volume customers. VERSATILE & ACCESSIBLE Data Rack A mobile or stationary solution which will astonish you with its versatility. Design Its torsion resistant frame of 14ga/2mm is welded together and has a high load capacity. The 6-fold, roll-formed, vertical frame members are punched in front and back for mounting 19" components and have additional installation holes on the sides. Available with one or two mounting surfaces. Customers Contractors, offices, IDFs and data rooms. Applications Open rack system for installation in distribution rooms, for flexible networks and for laboratory systems. Components installed on their one or two mounting surfaces are accessible from all sides. Network components Active components Passive equipment Other 19" rackmount applications Environments IDFs Data rooms MIS applications LAN equipment Hot Buttons Installation holes on base, sides and rear Easy portability and access Stand alone or interconnected Base can be bolted to floor or mounted on twin wheel casters Second mounting frame available Torsion free frame Cost A versatile and cost-efficient solution. STYLISH & FLEXIBLE RiPatch A solid choice for efficiently organizing and maintaining your network. Design Manufactured in 1.5mm sheet steel, the RiPatch frame is designed for high density cable applications. Easy to assemble and install, thanks to its modular design and active equipment accessories. Customers Consultants, system integrators, data rooms and showroom applications. Applications High density structured cabling management system for efficiently organizing and maintaining copper and fiber backbones. This easy to install system offers 42U of usable equipment mounting space for CAT5, CAT5E, and CAT6 applications. Network components Active components Passive equipment LAN/WAN Other 19" rackmount applications Environments Showcase and MIS applications Data rooms LAN equipment High density copper and fiber installations Hot Buttons Stylish for showcase applications Bolted to floor Stand alone or interconnected Sheet metal construction providing solid cable protection Simple installation with a minimum of parts Cost Solid design providing enduring cost-effective performance. 31

33 Quick Selection Guide BasicRack Accessories Part No. U inches mm Color Rack Double Adjustable Divider BR storage sided monitor shelf H W D H W D drawer shelf shelf Clear Black Clear Black Data Rack Accessories Part No. U inches mm Leveling Second mounting 2U fixed shelf Twin Depth Baying DK H W D H W D feet frame casters bars kit RiPatch Accessories Part No. U inches mm 6"/150mm 12"/300mm Plinth-frame Extended 6"/150mm 12"/300mm Top cover RI H W D H W D baying kit baying kit spacer plinth baying baying cable guide 100mm tubes tubes tubes Comparison Guide BASICRACK DATA RACK RIPATCH STANDARD & ECONOMICAL VERSATILE & ACCESSIBLE STYLISH & FLEXIBLE APPLICATIONS Equipment Termination Telecommunication Seismic/Zone 4 EMC DIFFERENTIATION Price Modularity Attractiveness Knock-Down Ability Accessory Range Climate Control Fan trays Fan trays Special Paint Extensive Modifications KEY = Highly recommended = Recommended = Not recommended 32

34 19 Open Rack Solutions With... BASICRACKS Rittal s 19" BasicRack is the perfect solution for standard equipment applications and basic 19" component installations. This rack is bolted to the floor for greater stability, either standing alone or interconnected for larger projects. Because of the simple design of this Rittal rack, users will benefit with easy access to equipment as well as quick assembly and installation. If you are looking for a complete, low-cost but high-quality basic equipment management system, Rittal s BasicRack is the ideal solution. C ONFIGURATION Knock down in one package All hardware for installation 2 aluminum extrusions 5/8" - 5/8" x 1/2" hole pattern tapped screw holes Available in clear chemical coat and black paint BasicRacks Accessories Part No. U Dimensions Color Rack Double Adjustable Divider *3' vertical *7' vertical Sliding 19" key BR inches storage divider monitor shelf cable cable extension board drawer shelf shelf manage- manage- shelf w/mouse H W D ment ment pad Black (f) Clear (f/r) Black (f) (f) Clear (f/r) (f/r) * All vertical cable management is black. f = Front r = Rear Note: please reference page 77 for technical drawings. 33

35 Achieve Unparalleled Accessibility With... DATA RACKS Monitor, server, keyboard, printer and other network components can find a safe shelter in these racks. A second 19" mounting frame facilitates installation of component shelves, slide rails, or cable management solutions. Together the Rittal Data Rack, optional second mounting frame and our comprehensive accessory program offer smart solutions for a multitude of network applications. C ONFIGURATION Data Rack 19" vertical frame Base with integrated feet Captive nuts and screws ordered separately Light grey (RAL 7035) frame highlighted with teal (RAL 5018) trim Mounting Frame (additional) 19" frame including installation hardware Data Racks Accessories Part No. Dimensions Usable Additional Baying 2U fixed Twin 20" Telescopic Depth Leveling DK inches height mounting kit shelf casters shelf* slides* bars* feet H W D frame "/31U "/36U "/40U "/45U * Second mounting frame required for telescopic rails or shelf other than 2U fixed shelf. Note: please reference page 77 for technical drawings. 34

36 Smart Cable Management Racks... RIPATCH Rittal s RiPatch high density structured cabling system is a smart solution for copper and fiber backbones. This easyto-install system offers 42U of usable equipment mounting space for CAT 5, CAT 5E and CAT 6 applications. With a foot print of 600mm wide and 450mm deep, the RiPatch frame can be an ideal product for back-to-back, freestanding or wallmount requirements. The sidewalls act as a cable tray, providing maximum space for hardwired cable management. A wide range of active equipment accessories also accompanies the system. C ONFIGURATION 42U mounting frame Extendable floor plinth 50mm (2") plinth spacers Top cable trough, extendable Plain top cover Assembly hardware 1.5mm sheet steel with RAL 7035 (light grey) finish and RAL 5018 (teal) trim * 10 cable fingers not included RiPatch Accessories RiPatch 42U unit U Dimensions 6"/150mm baying kit 12"/300mm baying kit Cable fingers 19" rackmount Vented top covers Row end sidewall inches fan tray H W D Note: please reference page 78 for technical drawings. RiPatch Accessories Vented Top Cover Ventilated top cover for active equipment applications is retro-fitted to standard frame. Optionally a ventilated top cover with 3 off AC fans fitted is available. Material: sheet steel Finish: RAL 7035 (light grey) Description Part No. DK Vented only Vented/fans

37 Baying Kit Available in either a 150mm or 300mm baying kit which allows you to decide on the size of a cable-way required between frames. Fitted between 2 RiPatch frames, this kit provides the base plate and baying tubes which provide the cable management needed. Configuration: 1 off plinth infill plate, 2 off fixing plates and screws, 6 off clip-in baying tubes Length Part No. DK 6"/150mm "/300mm Material: sheet steel, baying tubes of tubular steel with nylon inserts for fixing to frames Finish: RAL 7035 (light grey), powder coated Cable Fingers ABS tubular plastic cable fingers clip in to rounded front face of frame, providing cable management of cables presented to 19" patch panels. Material: ABS injection mounted plastic Finish: RAL 5018 (teal) Packs of Part No. DK Extended Plinth Infill Kit This accessory is required when the floor plinth is extended, filling the gap in the plinth frame, and giving a smooth finish to the now extended floor tray. Material: sheet steel Finish: RAL 7035 (light grey) Description Part No. DK Single kit Baying Tubes As supplied in the baying kits, but available as an accessory in packs for additional primary cable management as required. Simplicity to fit with their clip in fastening system, even when system is fully populated and in service. Size Packs of Part No. DK 6"/150mm "/300mm Material: tubular steel tube, with nylon inserts for clip in fixing Color: RAL 7035 (light grey) Configuration: 6 tubes and assembly parts Row End Sidewall Used to finish a suite of RiPatch frames, the 450mm deep panel includes: Marker board Document pocket Fixing hole for cable hoops or spare cord storage. The end row panels should be used in conjunction with a 150mm baying kit, ordered separately. Packs of Part No. DK Material: sheet steel Finish: RAL 7035 (light grey) Top Cover Cable Guide Tubes Fitted vertically into the fixing provided at the top of the frame, these guide tubes ensure that cables can be pulled across the roof section of the system without being managed. The tubes ensure a smoth guide, and also ensure minimum bend radii is maintained. Pack of Part No. DK Material: tubular steel Finish: RAL 7035 (light grey) 36

38 Rittal s Comprehensive Family Of... WALLMOUNT CABINETS 37 FUNCTIONAL & COST-EFFICIENT QuickBox In every respect the QuickBox is the optimum combination of the proven quality and flexibility of Rittal enclosures. Design Wallmount panel for 19" or metric components. Cover has vent slots for ventilation through convection, also accepts fans. Viewing door or sheet steel door with lock for access from front. Cable entry panels with brush insert and integrated cable collecting rail. The removable cover makes installation very easy. Customers Contractors and installers Educational Government institutions Applications A smart solution for small networks or floor distributors, based on customers needs. One of its outstanding features is the easy and unobstructed access to all components and wiring. QuickBox offers a complete solution ideal for educational applications. Termination equipment Networking equipment Environments Data rooms and office spaces Passive equipment School facilities Hot Buttons Cost-efficient and secure One enclosure, 12 models Off-the-shelf, completely assembled Versatile 2-Part design Cost QuickBox is cost-efficient and available off-the-shelf. INCREASED SECURITY & SERVICEABILITY AE Series 2-Part An ideal solution for simple wallmount installations while assuring only authorized entry. Design Wallmountable design with built-in swing frame for access to rear of equipment. Secure and sturdy with NEMA 12 protection available. Roll-formed construction provides high stability and component protection. NEMA 4 and 12 versions. Customers Educational applications Office buildings and hospitals Small clusters of workstations Applications An ideal solution for simple wallmount installations while assuring only authorized entry. Ideal for small networks or floor distribution in environments that require a high degree of security and a high industrial protection rating. Active components Networking and monitoring equipment Termination equipment Environments NEMA 12 environments Smaller networks Remote models Climate consideration Offices or factory environments Hot Buttons Wallmountable design NEMA 12 protection available Wide range of accessories Built-in swing frame Secure and sturdy Cost AE 2-Part is a cost-effective and versatile solution. ULTIMATE FLEXIBILITY & ACCESSIBILITY EL Series 3-Part Provides a perfect solution for packaging electronic equipment even under extreme conditions. Design Wallmount section with cable entry gland panels. Hinged swing-out center section for easy access to components and wiring. Depth-variable 19" mounting surface. Customers Educational applications Office buildings and hospitals Small clusters of workstations Applications This wallmount is ideal for small networks or floor distribution in environments that require a high degree of security and a high industrial protection rating. Active components Networking and monitoring equipment Termination equipment Environments NEMA 12 environments Offices, schools, and hospitals Factory floor applications Hot Buttons Separate, swing-out center section for front and rear component access NEMA 12 protection Wide range of accessories Sturdy design provides solid support for equipment Cost EL 3-Part is a high value solution for high end needs.

39 Quick Selection Guide QuickBox Accessories Part No. U inches mm Wallmounting 19" rails Slide/support Combination QB bracket, 1.6" rails for enclosure rails for enclosure H W D H W D depth depth Note: For QuickBox models with solid door, replace fifth digit of part number with a 1 i.e AE Series 2-Part Accessories Part No. U inches mm Wallmounting C-rails Support rails DK H W D H W D bracket, 1.6" EL Series 3-Part Accessories Part No. U inches mm Wallmounting 2U Fan Replacement DK H W D H W D bracket, 1.6" shelf filter Comparison Guide QUICKBOX FUNCTIONAL & COST-EFFICIENT AE SERIES 2-PART INCREASED SECURITY & SERVICEABILITY EL SERIES 3-PART ULTIMATE FLEXIBILITY & ACCESSIBILITY APPLICATIONS Equipment Termination Telecommunication Seismic/Zone 4 EMC * DIFFERENTIATION Price Modularity Attractiveness Accessory Range Climate Control Fans Fans Fans, A/C Special Paint Extensive Modifications KEY = Highly recommended = Recommended = Not Recommended * EMC versions are available. Please contact Rittal. 38

40 Versatile Wallmount Solutions... QUICKBOX ENCLOSURES Rittal s new QuickBox wallmount enclosures combine variety with flexibility and cost efficiency. With its depthadjustable 19 mounting surface, the QuickBox is the ideal solution for packaging network equipment or floor distributors. One enclosure, 12 models - that means 12 standard products instead of complicated custom fabrication. Choose from a large selection of sizes, with or without viewing door, that offer cost-efficient, customer-oriented solutions for the most diverse applications. The QuickBox is available off-the-shelf, completely assembled. In every respect the QuickBox is the optimum combination of the proven quality and flexibility of Rittal enclosures. C ONFIGURATION Wallmount section with 19" rails and brush inserts Housing cover with base Cover with vent slots and brush inserts Sheet steel or viewing door options Security locks on front door and two sides Cable collecting combination rail Front 19" rails, infinitely depth adjustable RAL 7035 (light grey) QuickBox Accessories Part No. U SU Height 19" rails Cable Cable 19" Shelf* Telescopic Shelf Telescopic Shelf QB inches collecting collecting component 16" deep slides* 20" deep* slides handle rails rails shelf 2U 16" deep 20" deep (depth) (width) 24" Wide x 24" Deep With Viewing Door " " " " " " " Wide x 24" Deep With Solid Door " " " " " " *Need second set of 19 rails for rear of wallmount. 39 Note: please reference page 79 for technical drawings.

41 QuickBox Accessories 19" Component Shelves 2U Can be installed: In enclosure between 19" rails In swing frames with special 19" angles In vented component shelves with 19" rail mounting Material: sheet steel Color: light grey (RAL 7035) For installation in fixed position or on telescopic slides mm inches Part No. DK W D W D Vented component shelves (with 19" rail mounting) mm inches Part No. DK W D W D Telescopic Slides For Component Shelves The slides are easy to install and can also be used to convert fixed shelves to sliding shelves, in which case the existing fastening bolts are replaced with the telescopic slides and fastened to the 19" rails. Configuration: telescopic slides have two stops and can be mounted in standard installation holes. Load capacity per pair: 110 lbs/50kg Material: sheet steel For component Packs Part No. shelf depth of DK 11.81"/300mm 1 set "/400mm 1 set "/500mm 1 set Note: second set of 19 rails for cabinet is necessary. Combination Cable Collecting Rails Feature sprockets on top and bottom to which cable ties can be fastened, while cable clamps can be fastened to the built-in C-rail. Material: aluminum Configuration: 6 combination rails, installation hardware For Length Packs Part No. enclosure of DK depth 15.75"/ 7.87"/ mm 200mm For Length Packs Part No. enclosure of DK width 23.62"/ 15.75"/ mm 400mm Internal Enclosure Fan This internal enclosure fan helps to avoid hot spots and supports air routing of active enclosure climate control components. It is adjustable on two axes and can be fastened to the frame section. Configuration: Complete unit, ready for installation, with radial fan and swing bracket as well as installation materials. Air displacement Rated Part No. (unimpeded voltage SK air flow) Volt/Hz 100 cfm 115/50/

42 Secure Your 19 Components With... AE SERIES 2-PART ENCLOSURES Designed for smaller network and/or remote modes, Rittal s 2-Part wallmount enclosures allow easy serviceability and access to equipment while assuring only authorized access. The 19 swing frame produces simple mounting of mini-hubs, patch panels, power strips or other 19 components. The single sheet, roll-formed construction of the 2-Part enclosures provides high stability and component protection. For increased airflow and improved overall cooling, wallmounting brackets can be installed in predrilled holes of the enclosures. Rittal s 2-Part wallmount enclosures are an ideal solution for simple wallmount installations. C ONFIGURATION 16 ga/1.5mm single sheet steel housing painted RAL 7032 (pebble grey) 19 steel swing frame painted RAL 7032 (pebble grey) 14 ga/2mm solid steel door with 3mm impact resistant, acrylic glass and seamless foamed-in-place gasket NEMA 4 solid door versions and NEMA 12 viewing door versions Includes 12 clip nuts ( ) and 12 installation screws ( ) Maximum component depth of /265mm 2-Part Wallmount Enclosures Accessories Part No. U Description Dimensions.4"/10mm 1.6"/40mm Security 19" rack- 38 cfm Outlet DK inches mm wall- wall- lock mount filter filter mounting mounting insert power strip fan H W D H W D bracket bracket 15 amp Part with solid door Part with zip-gasket window Part with solid door Part with zip-gasket window Part with solid door Part with zip-gasket window Usable rack space 1U=1.75 Note: please reference page 79 for technical drawings. 41

43 2-Part Accessories 115V Power Strips For USA Complete with: Illuminated ON/OFF rocker switch Circuit breaker 6-foot power cord with plug 19" Rackmount Power Strips (not pictured) Attach to any 19" rails for convenient power source to components. Illuminated ON/OFF power switch High quality industrial strength 6-foot power cord with plug Number of outlets Amp Surge Approvals Color Part No /20 protection CSA UL DK 6 (3 duplex) - 15A X X X pebble grey (RAL 7032) (3 duplex) - 15A X X X light grey (RAL 7035) (3 duplex) - 15A X X light grey (RAL 7035) (3 duplex) - 20A X X light grey (RAL 7035) (3 duplex) - 15A X X X X light grey (RAL 7035) Wallmounting Brackets Utilize pre-drilled holes in rear wall. Version with 1.6"/40mm stand-off allows cable routing behind the enclosure. Material: steel, chromated Stand-off Packs Part No. dimension A of SZ 1.6"/40mm "/10mm Plastic Thumb-Turn Handle With Lock With 3524 E security lock insert, gasket, installation hardware and keys. Description Part No. SZ Handle with lock Security Inserts Material: die-cast zinc Description Part No. SZ Type B No E lock with 2 keys Ground Bus (Zero Potential Rail) These grounding rails can be installed in all freestanding and wallmount network cabinets. They make it possible to include every cabinet into a buildings grounding system. Ampacity: approximate 200 A. Configuration: 1 copper rail (E-Cu 57 per DIN 1759, DIN , 15 x 5mm, 20 grounding clips with M5 screws, 2 grounding clamps AWG 3/ 25mm 2, 2 isolators, installation hardware. Length Part No. DK 17.71"/450mm

44 Top Notch Security And Durability... EL SERIES 3-PART ENCLOSURES Rittal s wallmount network cabinets offer stability, accessibility and security to the networking specialist. All standard models feature usable panel heights from 9U to 21U, ensure safe packaging for sensitive components as well as protection from the environment and from unauthorized access. Double security is assured through separate locks on the center swing frame section and the front viewing door. Rittal s 3-Part wallmount cabinets a perfect combination of protection and versatility. C ONFIGURATION Rear housing with removable top and bottom covers Two vertical system bars Cable collecting rail Center swing frame with lock and two adjustable 19 rails Front viewing door with lock Adjustable 19 rails.4 wallmount brackets/standoffs 2 filters (not included in NEMA 12 versions) Ground bus Bottom cable gland panel with brush insert (not included in NEMA 12 versions) RAL 7035 (light grey) and 5018 (teal) RAL 7032 (pebble grey) and RAL 7033 (mortar grey) NEMA 12 versions EL 3-Part Enclosures Accessories Part No. U inches mm Wallmounting 2U Fan Replacement DK H W D H W D bracket, 1.6" shelf filter EL 3-Part Enclosures NEMA 12 Accessories Part No. U inches mm Mini Ergoform-S Lock inserts for C-rail Slide rails Rackmount DK handle Mini Ergoform-S shelf H W D H W D push/lock Note: please reference page 80 for technical drawings.

45 3-Part EL Accessories Fan Expansion Kit This kit includes one fan, 6'/1.8m cable/plug, finger guard and installation hardware. Technical Data: Rated voltage: 115 or 230V Rated current: 19/18 W for 50/60 Hz Air displacement (unimpeded air flow): 85/ 100cfm /140/165 m 3 /h for 50/60 Hz Temperature range: +14 F to +131 F/-10 C to +55 C Replacement Exhaust Filters Filters are standard equipment mounted on right and left side walls of center section. Voltage Packs of Part No. SK 230V fan 1 set V fan 1 set Packs of Part No. SK 5 filters Mini Ergoform-S Handle For 3-Part EL style wallmount network cabinets. Accepts SZ and SZ lock inserts. Color Part No. EL light grey (RAL 7035) pebble grey (RAL 7032) Secruity Packs Part No. SZ lock insert of No E Pushbutton with No lock Cable Entry Panel With Brush Insert Multiple roll-fold and welded, with foamed-on gasket and plastic brush insert for easy cable entry. Part No. DK RAL Wallmounting Brackets Utilize pre-drilled holes in rear wall. Version with 1.6"/40mm stand-off allows cable routing behind the enclosure. Material: steel, chromated Stand-off Packs of Part No. SZ dimension A 1.6"/40mm "/10mm " Component Shelves 2U Can be installed: - in enclosure between 19" rails, and - in swing frames with special 19" angles. Material: sheet steel Color: light grey (RAL 7035) For Installation In Fixed Position Or On Telescopic Slides mm inches Part No. DK W D W D

46 Technology-Driven Solutions To Help You Design... SMART APPLICATIONS UNIVERSAL SERVER SOLUTIONS IDEAL FOR ISP/ASP TOUGH DESIGN FOR ZONE 4 Mass Storage Demands on server cabinets keep increasing as servers continue to get deeper, heavier and run hotter. Rittal s line of server cabinets are designed to handle these stressful requirements and much more. Design VR Server: Power strips can be installed inside rear frame posts that also serve as cable ducts. PS Server: Completely welded, multiple rollformed, steel frame ensures high stability. Rittal Applicable Products PS and VR server cabinets Climate control Full line of accessories Applications Server equipment Show case applications High tech applications High-load bearing capacity Multiple types of equipment Advantages Unlimited individual solutions with Rittal s modular components and accessories Modern appearance and design with outstanding functionality Answers a wide range of network requirements Component mounting in fixed positions or telescopic positions Can be interconnected in row or suites Pre-configured solutions based on real world requirements Depth adjustable mounting of 19" and/or metric components Versatile design ISP Rittal is defining the standard for ISP/ASP applications with the versatile and sturdy PS cabinets. Whether your concerns are client security, cooling, wire management, multiple vendor mounting or attractive styling Rittal has the ideal ISP product for you. Design Completely welded, multiple roll-formed, steel frame ensures high stability. Standard system installation holes and extremely large assortments of accessories allow unlimited configurations. Rittal Applicable Products PS-based ISP cabinets Climate control Full line of Rittal accessories Applications ISP equipment Server equipment High tech applications Advantages Unlimited individual solutions with Rittal s modular components and accessories Component mounting in fixed positions or telescopic positions Exceptionally sturdy enclosure system Can be interconnected in row or suites Pre-configured solutions based on real world requirements Depth adjustable mounting of 19" and/ or metric components Showcase opportunities Versatile design Zone 4 Rittal offers standard products that have been tested and certified to NEBS GR-63 core requirements. These cabinets were tested with 1000 lbs installed in the cabinet to simulate the most stringent of network applications. Look to Rittal for smartly-designed Seismic/Zone 4 application products. Design Completely welded, multiple roll-formed, steel frame, reinforced with side cross braces and heavy duty base. The 800mm wide cabinets are also equipped with reinforced L server rails. Rittal Applicable Products PS-based Zone 4 cabinets Full line of Rittal accessories Applications Server equipment High tech applications Multiple types of equipment Seismic (Zone 4) areas Advantages Standard PS cabinet advantages (refer to PS server) Reinforced enclosure that has been built and tested, to fully comply with stringent seismic requirements Design and configuration to provide solid, stable and sturdy support for rackmounted networking equipment Tested under the most extreme conditions simulating real life seismic activity NEBS GR-63 compliant Zone 4 offered as a standard product 45

47 Rittal s Networking Products Are... CUSTOMER DRIVEN SOLUTIONS Server/Mass Storage Enclosures... Pages ISP Enclosures... Page 50 Seismic-Rated Cabinets... Pages Solutions For Education... Page 53 46

48 PS-Based Modular Equipment Cabinets For... SERVER / MASS STORAGE PS Server Cabinets Rittal s rugged PS server cabinets are an ideal solution for server applications. The Rittal freestanding server cabinets are based on Rittal s patented PS series technology, featuring a standard installation hole system for maximum space utilization. The cabinet s rugged construction offers the highest stability as well as high-load bearing capacity. The PS server is one of the most cost effective and versatile solutions in the market today. Advantages of the PS server cabinet include the fully perforated front and rear door that provides maximum airflow, a fully perforated roof that allows for cable entry (two 4 round cutouts) and 19 server type rails both in the front and rear for rackmount server applications. This cabinet also allows for maximum space utilization with a depth of 40 (other PS style cabinets are available). C ONFIGURATION Fully perforated front and rear doors Perforated roof with 2-4 round cutouts for cable entry Ergoform-S handles with pushbutton lock inserts, front/rear 19 L server rails, front/rear 6 system chassis (3 sets) 3 heavy duty base (only on 72"/ 1800mm and 78"/2000mm high) Bottom corner brackets with casters (only on 86"/2200mm high) Leveling feet RAL 7035 (light grey) or RAL 9005 (black) 100 mounting screws 50 captive nuts Accessories Part No. Part No. U Description Exact outside dimensions Power strip, Inter- Stabilizer System x 20 Server fan Caster RAL 7035 Black inches mm 8 outlet, connect- plate chassis support vented assembly kit RAL 9005 H W D H W D 20 amp * ing kit rail shelf** RAL 7035/ PS Server Cabinet / (without sidewalls) PS Server Cabinet / (with sidewalls) PS Server Cabinet / (without sidewalls) PS Server Cabinet / (with sidewalls) PS Server Cabinet / (without sidewalls) /black PS Server Cabinet / (with sidewalls) /black PS Server Cabinet / (without sidewalls) /black PS Server Cabinet / (with sidewalls) /black

49 PS Server Cabinets Accessories Part No. Part No. U Description Exact outside dimensions Power strip, Inter- Stabilizer System x 20 Server fan Caster RAL 7035 Black inches mm 8 outlet, connect- plate chassis support vented assembly kit RAL 9005 H W D H W D 20 amp * ing kit rail shelf** RAL 7035/ PS Server Cabinet / (without sidewalls) /black PS Server Cabinet / (with sidewalls) /black PS Server Cabinet / (without sidewalls) /black PS Server Cabinet / (with sidewalls) /black PS Server Cabinet / (without sidewalls) /black PS Server Cabinet / (with sidewalls) /black PS Server Cabinet / (without sidewalls) /black PS Server Cabinet / (with sidewalls) /black PS Server Cabinet / (without sidewalls) /black PS Server Cabinet / (with sidewalls) /black PS Server Cabinet / (without sidewalls) /black PS Server Cabinet / (with sidewalls) /black PS Server Cabinet / (without sidewalls) /black PS Server Cabinet / (with sidewalls) /black PS Server Cabinet / (without sidewalls) /black PS Server Cabinet / (with sidewalls) /black PS Server Cabinet / (without sidewalls) /black PS Server Cabinet / (with sidewalls) /black PS Server Cabinet / (without sidewalls) /black PS Server Cabinet / (with sidewalls) /black * For additional power strips, refer to pages ** Refer to shelf selection guide pages for additional information and a list of black shelves. Unlimited keying combinations are available for front/rear doors for high security applications. These unique key inserts provide pick resistance, physical strength, and key control. Electronic locking solutions are also available - please contact Rittal for additional information. Note: please reference page 80 for technical drawings. 48

50 VR-Based Stylish Equipment Cabinets For... SERVER / MASS STORAGE The VarioRack server cabinets offer a popular solution for a variety of rackmount server applications. In fact, this cabinet has been successfully accepted by several major server manufacturers to house their sophisticated equipment. The smart, stylish design makes the VR server cabinet perfect for mounting servers on 19 rails. Topping the features and benefits for the VR server cabinet is the perforated rear door that provides excellent ventilation, easy access via the removable sidewalls and innovative leveling feet to increase stability when heavy components are mounted. C ONFIGURATION Front viewing door with raised plexiglass Mesh rear door (fully perforated) Perforated roof with 2-4 round cutout for cable entry Ergoform-S handles with pushbutton lock inserts, front/rear 19 VR rails, front 19 L server rails, rear Base includes casters and leveling feet Accepts all standard VR accessories RAL 7035 (light grey) 100 mounting screws 50 captive units Part No. U DK VR Server Cabinets Description Exact outside dimensions inches mm H W D H W D Power strip 6 outlet, 15 amp Roofmounted fan tray, 110V, 4 fans Shelf installation kit* Accessories 20" 20" Heavy 2U partial deep telescopic duty shelf mounting shelf slides 20 deep rails Interconnecting kit VR Server Cabinet (with sidewalls) VR Server Cabinet (with sidewalls) VR Server Cabinet (without sidewalls) * Necessary for fixed shelf installation. ** Can only be mounted to front rails. Support rails for 24"/600mm** W/D Note: please reference page 81 for technical drawings. 49

51 Technology-Driven Enclosures For... INTERNET SERVICE SOLUTIONS Internet Service Enclosures Part No. Part No. Description U U per Exact outside dimensions RAL 7035 RAL 9005 com- inches mm partment H W D H W D Many businesses today are experiencing tremendous growth due to the explosion of the internet, thanks to the wealth of information, products, services and contacts obtained. Just as internet usage has grown, so does the need to safeguard and maintain the equipment for this powerful communications tool. Rittal s new Internet Service Provider enclosure line will provide you with smart, efficient and stylish network solutions for your next client application. Based on our PS enclosure body, the internet service enclosure features fully perforated front/ rear doors that offer maximum airflow as well as our patented Ergoform-S handles with security inserts for increased security. Climate control issues can be addressed with a 365cfm roof fan assembly and a temperature indicator for continuous thermal management. Rittal s ISP cabinets can provide you with a viable solution to maintain and manage internet data equipment. C ONFIGURATION 2, 3 and 4 door configurations with partition shelves Perforated roof with 1 (4" x 3") cable entry cutout with adjustable cover plate and 2 (9" x 3/4") cable duct entry cutouts on sides Cable ducts (top and bottom feed) 19" L server rails, front /rear Ergoform-S handles, front/rear, with security insert Perforated front and rear doors 3" heavy duty base Leveling feet System chassis (4 per compartment) 100 mounting screws 50 captive nuts RAL 7035 (light grey) or RAL 9005 (black) Accessories Server fan tray, 600 W RAL 7035/ PS Style Cabinet / 2 Door PS Style Cabinet / 3 Door PS Style Cabinet N/A 4 Door Note: please reference page 81 for technical drawings. Refer to shelf selection guide on pages for list of black shelves. 19" rackmount power strip (6 outlets/usa) 19" component shelves Twin casters kit Captive nuts M6 phillips screws 19" support rails Unlimited keying combinations are available for each compartment for high security applications. These unique key inserts provide pick resistance, physical strength, and key control. Electronic locking solutions are also available - please contact Rittal for additional information. 50

52 High Levels Of Shock And Vibration Protection With... SEISMIC-RATED CABINETS Rittal Offers New Zone 4 Cabinets With the explosion of high tech networking equipment deployed all over the world, many companies are seeing that equipment is being exposed to more and more hostile environments. One of the more demanding environments is any place there is a chance for seismic activity. The areas that are most susceptible to seismic activity have been identified as Zone 4. Rittal now offers a stylish enclosure that has been built, and tested, to fully comply with these stringent requirements. These enclosures offer a fully perforated front and rear door for visibility, security and good air movement. In addition, front and rear server style angles are mounted off of three sets of systems chassis to provide solid, stable support for rack mounted networking equipment. If you have an application that demands a strong, stable enclosure choose one of Rittals new Zone 4 certified cabinets. C ONFIGURATION Perforated front and rear doors Ergoform-S locking handles with pushbutton lock inserts Front and rear 19" L server rails mounted off 3 sets of systems chassis (Zone 4) Rugged Zone 4 cable base Zone 4 cross braces Perforated roof with 2-4" round cutouts for cable entry 50 captive nuts 100 mounting screws RAL 7035 (light grey) Zone 4 Seismic-Rated Cabinets Part No. 36U inches mm H W D H W D U Note: please reference page 81 for technical drawings.

53 Zone 4 Cabinet Specifications Rittal offers NEBS GR-63 compliant Zone 4 cabinets as a standard product. These cabinets were tested at an approved test lab to fully comply with all of Zone 4 requirements for enclosures. These cabinets were loaded with 1000 lbs of weight to simulate one of the most strenuous applications found in todays networking environment. This 1000 lbs of weight was distributed with 50% of the weight below the center of gravity of the cabinet and the other 50% located above. Seismic Zone 4 Seismic map provided courtesy of FEMA. Seismic Zone 3 Seismic Zone 2B Seismic Zone 2A Seismic Zone 1 Seismic Zone

54 QuickRack & QuickBox Network Products... SOLUTIONS FOR EDUCATION Rittal realizes the importance that computers and the internet are having on the education systems throughout the world. We also understand the large investment it takes to not only provide adequate computer resources and networking platforms, but to also maintain, manage and protect this equipment. Rittal s new QuickRack and QuickBox products offer a comprehensive product offering that is ideal for educational applications. Rittal s new line of QuickRack equipment racks is ideal for electronic and networking applications and offers a simple yet cost-effective solution. Features include leveling feet to help compensate for uneven floors, and ventilation slots in rear door to promote increased air circulation. The QuickBox wallmount enclosure line is an ideal low-cost solution for packaging network equipment or floor distributors. Topping the advantages of this new wallmount is a front viewing door which allows for constant observation and instant access, in addition to three security locks to protect against unauthorized access. For more information on the QuickRack and QuickBox products, please reference their individual product pages. QuickRack Network Cabinets Accessories Part No. Sidewalls U Exact outside dimensions Power strips Roof fan 19" rackmount QR inches mm 8 outlet, 15 amp tray shelf H W D H W D Yes No Yes No Yes No Yes No Yes No QuickBox Wallmount Enclosures Part No. QB U Exact outside dimensions Viewing Solid steel inches mm door door H W D H W D Note: please reference pages 74 and 79 for technical drawings. Accessories Wallmounting Wall- 19" rails Combination Combination Slide/ Fan/bracket bracket mounting rails for rails for support combination.4"/10mm bracket enclosure enclosure for enclosure 1.6"/40mm depth width depth

55 Rittal s Networking Products Offer... TOTAL SOLUTIONS CMC Basics... Pages CMC Computer Multi Control... Pages Accessories... Pages Air Conditioners... Page 71 Blower Systems & Filter Fans... Page 72 Server Fan Assembly... Page 73 Technical Drawings QuickRack... Page 74 PS... Page 75 VR... Page 76 BasicRack... Page 77 Data Rack... Page 77 RiPatch... Page 78 QuickBox... Page 79 2-Part AE... Page 79 3-Part EL... Page 80 PS server... Page 80 VR server... Page 81 ISP... Page 81 Seismic-rated... Page 81 Technical Appendix... Pages

56 It Pays To Ensure Security And Protection... NETWORK MONITORING WITH C The Rittal CMC offers a perfect, complete solution for network monitoring and security. There is an impressive range of benefits all of which are geared towards ensuring total system security. 1 FUNCTIONAL BENEFITS 2 COST BENEFITS 3 CONTROL BENEFITS Standard default settings mean that the CMC is ready to use immediately. The CMC equipment, both local and remote, can be administered centrally. Password protection is provided for the serial interface. There is nothing more costly than a system shutdown! You can help prevent this with the Rittal CMC enclosure monitoring system an important factor in limiting the risk of failure. Risk of failure Permanent CMC monitoring of numerous potential hazard sources significantly reduces the risk of a network failure and damage to expensive components. Investments Replacement investments can prove extremely costly in the event of a network failure. Weigh this up against the price of a cost-effective, PC-based Rittal CMC solution. Plain text display and LEDs on the CMC indicate the operating status and any possible faults. With network management software (SNMP/ Telnet), messages are portrayed on a network computer via an interface. This allows permanent monitoring of several connected enclosures from a single central control center. The parameters and terms can be set individually. CMC CMC PARIS TCP/IP Router TCP/IP CMC CMC CMC SNMP Remote control: Thanks to bidirectional data communication with the CMC, many of the enclosure s functions can be remotely communicated and controlled from the control center. 55

57 MC Complete Solutions CMC base unit Large range of accessories to complement the unit Own management software on Windows 95 NT Sensors for temperature, humidity, smoke and vibration monitoring Coded lock system Control of network voltage Competent Rittal service from planning through to assembly. Clear: Just two LEDs in three states: Green no malfunction; orange warning; red malfunction Always in view: The following are indicated in green: Link Connection to the network via 10BaseT interface. Traffic Data traffic on the network. Com Data exchange between the CMC/PC. PC interface: RJ 11 jack RS 232 for entering variables and inquiring status via the PC (menuassisted). The CMC speaks your language: The temperature is shown in the first line of the LCD display. The second line alternately shows the mains voltage, two analog values (in %) and the current fault in the form of a text message. Text messages may be freely selected. Easy handling: Switching values are set and the ten most recent error messages can be retrieved using three keys: Change To branch to a menu. Enter To select the various functions. C To acknowledge error messages. The acoustic alarm can likewise be acknowledged. 4 OPERATING BENEFITS The system parameters can be directly set using the front control keys, via a PC interface, SNMP or Telnet. The status can be retrieved on the display or PC screen at any time in plain text format. 56

58 Sensors, Lock Systems, Accessories & More... CMC SYSTEM BASICS 1 SENSORS Temperature sensor Promptly detects and avoids risks to components caused by temperature rises inside the network enclosure. Smoke alarm sensor The smoke alarm sensor facilitates the early detection of smoke inside the network enclosure. Hygro-thermosensor For monitoring relative air humidity/ temperature within the set limits. Vibration sensor Thanks to an adjustable level of sensitivity, it is possible to identify vibrations of varying intensity. Entry sensor Unauthorized access to the network enclosure is indicated and reported. Lock System 2 LOCK SYSTEMS Ergoform-S with electromagnetic lock The lock unit consists of a Rittal Ergoform-S with an electromagnetically locked swing lever. Ergoform-S with electromagnetic lock for QuickRack A new extra option for this economical enclosure variant. Security lock For locking PS doors with tubular door frames. Universal lock unit Consisting of a base unit (controlled via the CMC) and a lock counterpart. Smart card reader The smart card reader operates as a central unit to release the door. Magnetic card reader The magnetic card reader is supplied with three magnetic cards, each with a different four-digit code. General Accessories 3 GENERAL ACCESSORIES CMC socket strip Equipped with interference suppression filter and overvoltage protection. Junction box with mounting bracket For systemcompatible mounting in network enclosures. Cable ties The fast solution for fixing cables to the enclosure section or to mounting system parts. Nylon loop For problem-free release of attached cables or the addition of individual cables. Hygrostat Reports when a humidity alarm level is exceeded. Door-operated switch To report opening of a network door. 57

59 Connection Modules At-A-Glance Keyboard lock Four-digit numbers may be authorized in the CMC. The entered code is transmitted to the CMC via the I 2 C bus. Packs of Part No. 1. Connection technology 115V power cord Programming cable Connector kit for connecting accessories 1 kit Cable for sensor connection, 10m V power pack Cable clamp strap, narrow Cable clamp strap, wide Interference suppression capacitors for fans I 2 C booster Cable management Cable management module, mounting kit Cable management module with plug-in system *Accessories for connection cable RJ *Accessories for connection cable RJ *Accessories for extension cable RJ *Accessories for extension cable RJ Sensors Temperature sensor *Temperature sensor w/connection cable & connector Smoke alarm sensor *Smoke alarm sensor w/connection cable & connector Hygro-thermo-sensor *Hygro-thermo-sensor w/connection cable & connector Vibration sensor *Vibration sensor w/connection cable & connector Access sensor *Access sensor w/connection cable & connector Lock system / access protection Ergoform-S, electromagnetic lock *Ergoform-S, electromagnetic lock with connector Ergoform-S, electromagnetic lock for QuickRack PS locking bar H = 2000mm Security lock 24V DC Security lock 120V AC Universal lock unit Adaptor for PC reader units Adaptor for VR reader units Smart card reader *Smart card reader w/connection cable & connector Magnetic card reader *Magnetic card reader w/connection cable & connector Coded lock *Coded lock w/connection cable & connector General accessories CMC socket strip with monitoring CMC alarm signal lamp Junction box Cable ties for quick assembly Nylon loop, 130mm Nylon loop, 200mm Nylon loop, 300mm Hygrostat Door-operated switch * For use with

60 CMC Network Monitoring Software Rittal CMC Manager Rittal s own management software runs under Windows 95/NT. Simply enter the required IP address, and the connection can be made immediately. As you would expect, the CMC Manager also includes a trap receiver which documents the alarms of all available CMCs in the network with the date, time, address and name. Here are just a few of the convenient functions offered by this SNMP program: The CMC s management information base (MIB) is incorporated into the software and included in the graphical structure. The mains voltage value is graphically portrayed. The temperatures and any analog input values are graphically portrayed. The setpoints of the CMC can be modified directly. Photographs may be incorporated in order to personalize the software. These are configured with control fields in a setup menu. The interface texts may be designed individually. The alarm trap messages may be linked to a WAV file, so that the administrator receives an acoustic warning. Other EXE or BAT files can also be appended to the trap messages, in order to initiate counteractive action automatically. The CMC manager allows continuous data recording for up to 10 devices. The CMC manager monitors the direct availability of all CMCs with the live check function. HP Open View Network Management System SNMP management programs such as HP Open View allow the CMC to be incorporated and addressed via SNMP. The required MIB is included on disk. The MIB is easily incorporated by simply copying. The MIB-II standard (RFC 1213) is also supported and is included with the supply of the NMS. The private MIB contains all values, statuses, settings and setpoints, and may conveniently be linked to the functions of the HP Open View software. Cabletron SPECTRUM Enterprise Manager Management System The graphical user interface for the SPECTRUM Enterprise Manager covers every conceivable requirement. The MIB variables are arranged on the interface in a user-friendly configuration. This professional software package combines the highlights of the CMC monitoring system with the best features of the Cabletron product. Additional modules also allow the alarm trap messages to be relayed via voice mail. The user is notified of the event by telephone, giving details of the date, time and place. The trap function can also be incorporated into the SPECTRUM Element Manager. 59

61 Programming Software For CMC Extension Units The programming software (Windows 95/NT) permits user-friendly configuration and logical operation of the CMC extension units. Two extension cards are available for the CMC. A user-friendly configuration software package is included with the supply, in order to facilitate logical linking of the inputs and outputs. AND, OR, NOT and TIME elements may be used. The graphical interface runs under Windows 95/NT and is easy to use. The logic may be transmitted to the CMC in the network via TFTP or directly via the RS 232 interface. TELNET The CMC menu program can be activated via TELNET (VT 100). Settings and inquiries may be implemented. The CMC menu software and the TELNET server become active upon startup of the CMC. Terminal Via Serial Interface The CMC menu program can be activated via standard terminal programs. Settings and inquiries may be implemented. The CMC menu software becomes active upon start-up of the CMC. 60

62 R Courtesy of Steven Engineering, Inc.! 230 Ryan Way, South San Francisco, CA ! Main Office: (650) ! Outside Local Area: (800) ! CMC Network Monitoring Unit Link Traffic Com Computer Multi Control So clear: Just two LEDs in three states: Green No malfunction Orange Warning Red Malfunction Always in view: The following actions are displayed in green: Link Existing network connection via 10BaseT interface. Traffic Data traffic on the network. Com Data exchange between the CMC and PC (via RS 232). 3 4 PC interface: RJ 11 jack RS 232 for entering variables and inquiring statuses via the PC (menu-assisted). The interface cable for the serial PC interface D-Sub 9 is included with connector kit DK The CMC speaks your language: The temperature is shown in the first line of the LCD display, while the second line alternately displays the mains voltage, two analog readings in [%], and any current malfunctions in the form of a text message. These text messages may be freely defined. 5 6 Easy to operate: Switching values are set and the ten most recent error messages can be retrieved using three keys: Change To branch to a menu. Enter To select the various functions. C To acknowledge error messages. The acoustic alarm is acknowledged. Acoustic alarm: A piezo signal generator reports an alarm. Of course, this is also switchable. Network Connection / Settings Via The CMC Menu Program From a central location, an administrator can monitor all network and server enclosures in internal networks and even in external networks (via WANs), initiate any servicing required, or implement settings on the CMC. German utility model no. G German reg. design no. M Danish design no. MR Norwegian design no Austrian design no UK reg. design no IR reg. design no. DM / with validity for BE, CH, ES, FR, IT, NL Indian design no CMC Computer Multi Control with 512 KB flash-rom program memory Packs of Part No. DK Rittal CMC network monitoring system, 1U, with Ethernet network interface and SNMP, Telnet (10Base2/10BaseT), RS 232 With new network functions: 4 trap receive IP addresses Programming and software update via Trivial File Transfer Protocol (TFTP) RS 232 access via password only Greater network security with SNMP via authorization check Alarm messages via ISDN with Vds protocol available on request. For the CMC DK , the extension units additionally allow the provision of up to 16 temperatures, 16 digital inputs and 4 relay outputs. 61

63 EXT 10BaseT 10Base2 I 2 C Analog Input Digital Input Relay1 Relay2 Alarm Power Fan1 Fan2 Out / In V 50/60 Hz 20 VA Power / UPS RJ 12 jack Serial interface for additional extension of the CMC for future use. RJ 45 jack Integral Ethernet interface to IEEE via 10BaseT. RJ 45 jack For use with I 2 C extension units. Analog inputs 10-pole connector for two temperature sensors, two times 4 20 ma and extension via I 2 C bus Digital inputs 20-pole connector for seven input signals (floating contacts) and 24V DC voltage source. Relay 1 Changeover contact 250V AC, 5 A as standard for heater. Relay 2 Changeover contact 250V AC, 5 A as standard for latch mechanism Alarm relay Changeover contact 250V AC, 5 A. Each error message can be set to initiate activation of the alarm relay (freely configurable). Fan relay 12-pole connector with mains voltage monitoring and two relays for fans. Voltage supply The CMC is supplied with voltage via the IEC 320 socket. Cable clamping/cable management The 2 screws are designed for cable clamp rails DK /DK Technical Information Dimensions Temperature range Processor Main memory Program memory Rated voltage Rated consumption Permissible voltage drop time Internal CMC power pack output Serial interface Ethernet connection Optical/acoustic displays Input Digital inputs (power requirement per input: 7 ma) Analog inputs 1U, mm (19 ) rack mount with 105mm installation depth +5 C to +45 C AM186-(20 MHz), 16-bit CPU, Intel-compatible 512 kb 16-bit DRAM 256 kb flash EPROM 100 to 240V AC, 50/60 Hz, IEC 320 socket 20V A max. 10 ms 24V DC, max. 100mA RS 232 for programming / linking to a PC 10BaseT, IEEE (10 MB/s), TCP/IP, SNMP, TELNET 5 LEDs, LCD display with 40 characters, piezoelectric signal generator 3 membrane-sealed keys 7 (vibration/smoke/door/swing lever/reader unit/ups1/ups2) 4 (temperature 1/2 and 2 current inputs 4 20mA) Monitoring functions 3 (mains voltage, fan current 1, fan current 2) Relay outputs 3 (fan 1/2) 3 A / 250V, normally open contact Relay outputs 3 (heater/lock/alarm) 5 A / 250V, changeover contact Extension I 2 C bus and CMC-EXT Monitoring And Control Functions Fan control circuit 1 Analog input for temperature sensor 1, relay for fan 1 Fan control circuit 2 Analog input for temperature sensor 2, relay for fan 2 Heater control circuit (See temperature sensor 1/2), relay for heater Temperature monitoring 1 (See temperature sensor 1), max./min. temperature values Temperature monitoring 2 (See temperature sensor 2), max./min. temperature values Voltage monitoring Analog input (for mains voltage) Free analog sensor input 1 Analoger input 4 20mA with limit monitoring Free analog sensor input 2 Analoger input 4 20mA with limit monitoring Vibration monitoring Digital input (parallel connection possible) Smoke monitoring Digital input (parallel connection possible) Door/access monitoring Digital input (series connection possible) Door locking control Digital input for Ergoform-S swing lever (series connection possible) Door locking control Digital input for reader units Relay for Ergoform-S handle or other lock systems Monitoring of UPS 1 Digital input (parallel connection possible) Monitoring of UPS 2 Digital input (parallel connection possible) Alarm output Freely programmable relay alarm output 62

64 CMC Extension Unit I 2 C Bus CMC Extension Unit, Temperature An extension unit for 8 additional temperatures may be connected to the CMC DK Alarm limits may be preset for all temperatures. Limit violations are reported via the base unit with SNMP. Eight RJ 12 jacks are provided for the connection of temperature sensors. Technical data: Temperature inputs: 8 x NTC (DK ) Rated voltage: 24V DC Rated current: 140mA Interface: I 2 C, max. cable length 2m CMC extension unit Part No. DK 8 x temperature inputs The following are additionally required for connection to the base unit DK : Cable for 24V, Part No. DK Cable for bus connection, Part No. DK Connector kit for base unit, Part No. DK Cable clamp strap, Part No. DK V power pack for voltage supply, Part No. DK NTC temperature sensors with RJ 12 connectors, Part No. DK CMC Extension Unit, I /O + Temperature Up to two extension units, each with 4 additional temperatures, 8 digital inputs and 2 relays, may be connected to CMC DK Alarm limits may be preset for all temperatures. Limit violations or alarms are reported via the base unit with SNMP. Technical data: Temperature inputs: 4 x NTC (DK ) Digital inputs: 8 (supply 24V DC per 7mA) Relay outputs: 2 (changeover contacts 5 A / 250V) Rated voltage: 24V DC Rated current: 140mA Interface: I 2 C, max. cable length 2m CMC extension unit Part No. DK 4 x temperature inputs 8 x digital inputs x relay outputs The following are additionally required for connection to the base unit DK : Cable for bus connection, Part No. DK Cable for 24V/sensor connection, Part No. DK Connector kit for base unit, Part No. DK Cable clamp strap, Part No. DK V power pack for voltage supply, Part No. DK NTC temperature sensors with RJ 12 connectors, Part No. DK CMC 2 U Acccessory Unit Supplied without CMC 2U Accessory Unit With the plug and play compatibility system, the CMC accessory unit is simply fitted into the 482.6mm (19") section, and voila! It contains two fans and is installed in the uppermost position of a network enclosure. The roof plate of the enclosure must be equipped with vent holes. The unit is fully wired and a CMC (DK ) is simply integrated into the bottom section. The CMC basic module is not included with the supply of the unit. The unit contains a number of functions, which are listed below: Functions of the unit: Monitoring of the mains voltage Monitoring of the temperature Temperature control via two separate fan circuits Smoke monitoring Vibration monitoring Entry monitoring for the front and rear doors Accessory unit Part No. DK 2U Jacks for extension with: UPS DK Electromagnetic Ergoform-S front door DK Electromagnetic Ergoform-S rear door DK Reader units DK /381/382 Hygro-thermo-sensor DK In conjunction with base unit DK , the following are additionally required: One connection cable 230V, Part No. DK (or other country-specific versions) 63

65 Connection Accessories Power Cable Power is supplied to the CMC base unit via the connection cable. Technical specifications: PVC cable, 3-pin with earthing-pin connector and IEC cable coupler (for non-heating appliances) with CEE22 contact protection. Supply includes: 1 connection cable, length 2.5m Country- Voltage Part No. DK specific versions USA/CDN D/F/B Note: Important accessory The connection cable is absolutely necessary for CMC operation. Connector Kit For Connecting Accessories The sensor cables are fastened directly to the respective connector from the connector kit, which is then plugged into the CMC base unit. In this way, the plug connections to the CMC are easily removed and re-installed during maintenance and assembly in the network enclosure. Programming Cable For The RS 232 Interface The RJ 11 jack is connected to the CMC front, the 9-pin Sub-D to a serial PC interface. Packs of Part No. DK 1 set Note: Important accessory The connector kit is absolutely necessary for connection of accessory coupling and PC connection. Supply includes: 1 connector kit consisting of: 3 tension spring clamps, 3-pin, 1 tension spring clamp, 10-pin, 1 tension spring clamp, 20-pin, 1 tension spring clamp, 12-pin. Packs of Part No. DK 1 set NEW programming cable for the CMC II DK Cable For Sensor Connection The 10m long cable can be cut to the exact length required, for optimum connection of sensors, Ergoform-S and access units in the enclosure to the CMC base unit. Technical specifications: LiYY 4 x 0.25mm 2 Supply includes: 1 cable, 10m long Required for: Smoke alarm sensor Hygro-thermo sensor Vibration sensor Entry sensor Locking units 24V DC Smart card reader Magnetic card reader Keyboard lock Socket strip Signal lamp Extension bus I 2 C Part No. DK Cable 10m long

66 Power Supply 24V This power pack is used to supply power to the smoke sensors and the Ergoform-S handle with card or coded lock. For fixing of power pack use cable clamp strap DK , see below, or cable management module DK Technical data: Input: V ± 10%, 50/60 Hz /AC Output: 24V DC/0.6 A Supply includes: 1 power pack with top hat rail and fastener for top hat rail, including assembly parts Version Part No. DK Power pack 24V DC Required for power supply of: Ergoform-S handle Locking unit 24V DC Smart card reader Magnetic card reader Keyboard lock Smoke alarm sensor Hygro-thermo sensor Signal lamp Extension bus I 2 C Cable Collecting Bar For mounting to the rear of CMC. Cables are fixed by means of cable ties. Narrow version: Only for cables. Wide version: For screened cables with spring terminals, and contacting, as well as fixing of power pack. Material: Sheet steel 2mm, zinc-plated, passivated. Supply includes: Cable clamp strap including assembly parts Version Part No. DK narrow, for cable clamping wide, for cable clamping, power pack fixed by means of terminal springs Recommended accessory Suppressor For Fans The capacitors eliminate interferences of the fans with self-starting shaded-pole motors. Each fan motor should be provided with a capacitor which is switched in parallel to the net voltage. The capacitors are equipped with terminals so that they are simply connected to the fan cable. Technical data: Dielectric strength: 275V AC Capacity: 100 nf Type: X2 Version Packs of Part No. DK 100 nf Following fan systems include self-starting shaded-pole motors: (e.g. SK , SK , SK , SK , SK , SK , SK , SK , SK , DK and variants). The fans or the vented roofs can be alternatively equipped with line filters. Line filters available on request. Booster 7 m Reader unit, extension unit DK Booster I 2 C-Booster The I 2 C-Booster is used to reinforce the signal of the CMC I 2 C bus system. It can be used optionally. The reader units and extension unit DK require 2 boosters. One booster is required for the extension unit DK Booster 7 m Extension unit DK Pack of Part No. DK * * Extended delivery time. Technical data: Max. cable length: 7m Further lengths available on request. Rated voltage: 24V DC Rated current: 50mA Interface: I 2 C Operating temperature range: +5 C to +45 C CMC CMC 65

67 CMC Cable Management Cable Management Module, Mounting Kit For mounting on the 482.6mm (19") section or on the enclosure frame. The cable management module may be fitted at a readily accessible point in the enclosure. Even in fully populated network enclosures, installation work and modifications can still be carried out to perfection. The supplied CMC connection cable gives access to all sensor connections in the cable management module. A top hat rail accommodates terminals or the 24V power pack. The cable may be connected to the sensors using the supplied terminals. Open/ individual wiring is possible. Version Part No. DK Mounting kit Width: 482.6mm (19") Height: 1U Depth: 143mm + 12mm Material: Sheet steel, 1mm, passivated Supply includes: Base section, cover plate, terminal blocks, top hat rail, 482.6mm (19") bracket, mounting bracket and CMC connection cable In conjunction with the CMC, the following are additionally required: 1 connection cable DK and 1 connector insert DK Cable Management Module With Connection System And 24V Power Pack For mounting on the 482.6mm (19") section or on the enclosure frame. The cable management module may be fitted at a readily accessible point in the enclosure. Even in fully populated network enclosures, installation work and retrofitting can still be carried out to perfection. The connection cable attached to the rear with the CMC connector kit is simply connected to the CMC. The front is equipped with 21 RJ 11/12 jacks, 4 terminals and an IEC 320 connection. All sensors are easily connected to the module using RJ 11/12 connectors. The 24V power pack is integrated into the wiring concept. Power for monitoring and for the heater, fan, alarm and power pack is supplied via the IEC 320 connection. Functional description/connection options: RJ 11/12 jacks for CMC accessories: 4 vibration sensors, Part No. DK entry sensors, Part No. DK UPS monitoring devices with cable, Part No. DK smoke sensors, Part No. DK electromagnetic Ergoform-S, Part No. DK Version Part No. DK Wired with sensor jacks door release with cable, Part No. DK I 2 C (reader units), Part No. DK / 381 / temperature sensors, Part No. DK analog sensors (e.g. hygrothermo-sensors), Part No. DK Terminals: 1 alarm (changeover contact for 250V AC, max. 5 A) 1 heater with fuse (normally open contact for 250V AC, max. 5 A) 2 fan systems with fuse (normally open contact for 250V AC, max. 3 A) In conjunction with the CMC, the following are additionally required: 2 connection cables, Part No. DK Technical data: Rated voltage: 24V DC Rated current: 600mA Dimensions: Width: 482.6mm (19"), Height: 1U, Depth: 100mm Temperature range: +5 C to +45 C Accessories Connection Cable RJ 11 / 12 The connection cables are prepared for cable management module DK The cable is equipped with an RJ 11/12 connector at one end, while the other end is open for the connection of sensors or actuators. Accessories Extension Cable RJ 11 / 12 The extension cables are prepared for cable management module DK The cable is equipped with an RJ 11/12 connector at one end, and an RJ 11/12 jack at the other end. The cables allow easy extension of the Connector P. of Part No. DK RJ RJ The cables facilitate individual wiring with the cable management module. Length 5m Connector/jack P. of Part No. DK RJ RJ connection between the CMC sensors and the cable management module. Length 5m 66

68 Sensor Accessories Temperature Sensor The economic solution for: Temperature measuring Temperature indication Temperature monitoring Temperature regulation Measuring transformers, one LCD display for indication as well as relays for fan control are made available via the excellent electronic equipment of the CMC. Two NTC sensors for two independent fan circuits/limit control sensors can be connected to one CMC. The temperature sensor, with its preassembled connection cable (2.5m) can be fitted anywhere in the network enclosure. The following are also required for connecting to base unit: Connector kit for connecting accessories, Part No. DK If a cable management module DK is used, no further accessories are required. Temperature sensor Part No. DK 2.5m connection cable m connection cable and RJ 12 jack for cable management DK Technical data: Type: NTC Resistance: 10 kohm at 25 C Tolerance: ± 1 C Connection lead: LiYY 0.25mm 2 Supply includes: 1 temperature sensor incl. 2.5m connection cable, cable support. Max. quantity for 1 CMC: 2 temperature sensors Note: The temperature sensors DK can also be used with the CMC extension units. Smoke Alarm Sensor The smoke alarm sensor is an optical smoke alarm consisting of an internal measuring chamber (with infrared LED and photodiode) and an electronic circuit board. If smoke enters the chamber, an LED light pulse is partially deflected by the smoke particles, causing it to strike the photodiode, which in turn triggers further light pulses. If these light pulses strike the photodiode again, smoke generation is signalled to the CMC and an alarm is triggered. The following are also required for connecting to the base unit: Cable for sensor connection, Part No. DK Connector kit for connecting accessories, Part No. DK Cable clamp strap, Part No. DK V power pack for voltage supply, Part No. DK The CMC s power pack is capable of supplying a smoke sensor with 24V. (Note: Observe total capacity). If a cable management module Part No. DK is used, no further accessories are required. Technical data: Rated voltage: 17 to 28V DC Closed-circuit current consumption: µa at 24V Make current: 90 µa at 24V Rated alarm current: max. 61 ma Temperature range: 20 C to +60 C Dimensions: Ø 100mm, H 50mm Weight: 150 g Smoke alarm sensor Part No. DK without connection cable m connection cable and RJ 12 jack for cable management DK Supply includes: 1 smoke alarm sensor including assembly parts. Smoke alarm sensor with VdS-approval no. G

69 3 Courtesy of Steven Engineering, Inc.! 230 Ryan Way, South San Francisco, CA ! Main Office: (650) ! Outside Local Area: (800) ! If a cable management module DK is used, no further accessories are required. Hygro-Thermo Sensor The hygro-thermo sensor determines the humidity/temperature and transfers these values into output signals mA. The sensor is based on 2-wire technology and requires external 24V voltage supply.the CMC monitors the humidity/temperature, indications in [%] The CMC has two analog inputs 4 20mA. The following are also required for connecting to the base unit: Cable for sensor connection, Part No. DK Connector kit for connecting accessories, Part No. DK Cable clamp strap, Part No. DK V power pack for voltage supply, Part No. DK The CMC s power pack is capable of supplying a hygro-thermo sensor with 24V. (Note: Observe total capacity) Hygro-thermo sensor Part No. DK w/o connection cable m connection cable and RJ 12 jacks for cable management DK Technical data: Rated voltage: 20 28V DC Rated current: 44mA Output signal: 4 20mA corresp. to 0 100% humidity 4 20mA corresp. to 0 50 C Measuring range: 10 90% humidity 0 50 C Operating temperature: 0 C to +50 C Supply includes: Hygro-thermo sensor, mounting bracket, including assembly parts. Vibration Sensor Vibration sensors are suitable for all fixed panels in the network enclosure. If possible, they should be fastened to the center of the side panel or door. If the enclosure is vibrated, the contact inside the sensor closes the circuit and triggers an alarm. The sensitivity of the contact is individually adjustable by means of an adjusting screw which presses onto a leaf spring. The sensor is an economic solution for monitoring vandalism. The high-quality electronic parts of the CMC transfers vibrations of different intensity into a CMC alarm. The following are also required for connecting to the base unit: Cable for sensor connection, Part No. DK Packs of 4 Part No. DK w/o connection cable m connection cable and RJ 11 jack for cable management DK Connector kit for connecting accessories, Part No. DK If a cable management module DK is used, no further accessories are required. Technical data: Contact rating: max. 50V, 0.1 A Dimensions: W x H x D: 57 x 21 x 18mm Supply includes: 4 vibration sensors including assembly parts. Entry Sensor Entry sensors monitor doors, side panels or windows in the network enclosure. The magnet is secured to the moving part (e.g. side panel), while the reed contact is fastened to the immobile part (enclosure frame). The permanent magnet holds the reed contact in a closed position. If the door is opened or the side panel removed, the reed contact drops out and opens the circuit, leading to an alarm in the CMC. The following are also required for connecting to the base unit: Cable for sensor connection, Part No. DK Connector kit for connecting accessories, Part No. DK If a cable management module DK is used, no further accessories as required Packs of 4 Part No. DK w/o connection cable m connection cable and RJ 11 jack for cable management DK Switching voltage: max. 100V DC Max. distance between reed contact and magnet: 5mm Supply includes: 4 entry sensors including assembly parts Technical data: Dimensions W x H x D: 55 x 13 x 13mm Switching load: 5 W Switched current: max. 500mA

70 Lock Accessories Important: Consider additional holes and locking rod. Ergoform-S With Electromagnetic Locking The lock unit consists of a Rittal Ergoform-S whose swing lever is electromagnetically locked. With the door closed and the swing lever in position, locking is activated by switching on the lock magnet. For monitoring the door an access sensor is required. The CMC allows the swing lever to be released out by deactivating the lock magnet, so that the door can be opened. Deactivation can be initiated by one of the access units shown below, such as smart card readers, magnetic card readers, coded locks or network management systems. Furthermore the Ergoform-S includes a handle monitoring system with a reed contact. The CMC triggers an alarm signal if the handle is not in position when door is closed. The pushbutton insert supplied can also be exchanged for security inserts. The following are required for connecting to the base unit: Connector kit for connecting accessories, Part No. DK V power pack for voltage supply, Part No. DK Bottom locking rod for CMC as per enclosure height (VR enclosures do not require a CMC locking rod). Entry sensor, Part No. DK / 331 Additional holes in enclosure door. Cable clamp strap Part No. DK If a cable management module Part No. DK is used, no further accessories are required. Color: RAL 7035 (light grey) Technical data: Rated voltage: 24V DC Rated current: max. 100mA Design Part No. DK 4m connection cable m connection cable and RJ 12 jack for cable management DK Supply includes: 1 Ergoform-S handle, 1 pushbutton insert, 1 connection cable, electromagnetic lock unit, assembly parts ± Security insert Design Part No. SZ Security insert Lock no E Security pushbutton insert Lock no E Locking rods Design Part No. DK Bottom CMC locking rod for 2000mm high PS enclosures Further information available on request ± Ergoform-S With Electromagnetic Locking For QuickRack The electromagnetic Ergoform-S handle for QuickRack is identical to Ergoform-S DK (for description see above). The following are required for connecting to the base unit: Connector kit for connecting accessories, Part No. DK V power pack for voltage supply, Part No. DK Additional holes in enclosure door (drawing see above) Design Part No. DK 4 m connection cable * * Extended delivery time. Cable clamp strap, Part No. DK Access sensor, Part No. DK Technical data: Rated voltage: 24V DC Rated current: max. 100mA 69

71 Smart Card Reader 3 smart cards with I 2 C chip (E-Eprom) are supplied with the smart card reader. Each card contains a four-digit code, which is different on all three cards. All cards are access-authorized (adjustable in the CMC). The four-digit code is transmitted to the CMC and, if applicable, to the network management system, via the I 2 C bus. Technical specifications: Type: Manual insertion reader Card type: Smart cards with I 2 C chip Supply voltage: 24V DC Power consumption: 150mA Interface: I 2 C bus Supply includes: 1 smart card reader, 3 smart cards Assembly parts, adaptor for PS glazed door 190 Part No. DK w/o connection cable m connection cable and RJ 12 jack for cable management DK Magnetic Card Reader 3 magnetic cards are supplied with the magnetic card reader. Each card contains a four-digit code, which is different on all three cards. All cards are access-authorized (adjustable in the CMC). The four-digit code is transmitted to the CMC, and if applicable to the network management system, via the I 2 C bus. Technical specifications: Type: Manual insertion reader Card type: Magnetic strip card with information on track 2 Supply voltage: 24V DC Power consumption: 150mA Interface: I 2 C bus Supply includes: 1 magnetic card reader, 3 magnetic cards assembly parts, adaptor for PS glazed door 190 Part No. DK w/o connection cable m connection cable and RJ 12 jack for cable management DK Keyboard Lock Four-digit numbers may be entered in the CMC. The authorized codes can be adjusted with the CMC via RS 232 or Telnet. The entered code is transmitted to the CMC and, if applicable, to the network management system, via the I 2 C bus. Technical data: Type: Keypad Rated voltage: 24V DC Rated current: max. 150mA Interface: I 2 C bus Supply includes: 1 coded lock assembly parts, adaptor for PS glazed door 190 Part No. DK w/o connection cable m connection cable and RJ 12 jack for cable management DK

72 Keep Your Electronics Cool With... AIR CONDITIONERS Rittal Pro-Ozone air conditioners are designed to provide reliable cooling performance in a variety of applications around the world. Providing temperature protection to sensitive electronics in ambient temperatures up to 131 F while integrating seamlessly into the enclosure is what sets Rittal air conditioners apart from the competition. Rittal offers a range of cooling options designed to give the right solution whenever optimum operating conditions inside the enclosure are required. C ONFIGURATION Roof and wallmount versions Includes terminal block and drilling template UL/CUL recognition, CE compliance CFC/HCFC-free R134a refrigerant RAL 7032 (pebble grey) Mini Air Conditioners Part No. Rated Dimensions Useful cooling Rated Starting Weight Mounting SK voltage inches mm capacity per DIN 3168 current current H W D H W D 95 F ambient, 95 F internal /50/ BTU/2400 BTU 5.1A/6.0A 25.2A/34.3A 35 kg/77.18 lbs Wall 680W/700W /50/ /1300 BTU 4.5A/5.2A 13.5A/13.5A 33 kg/72.76 lbs Roof 420W/380W Medium Wallmount Air Conditioners Part No. Rated Dimensions Useful cooling Rated Starting Weight SK voltage inches mm capacity per DIN 3168 current current H W D H W D 95 F ambient, 95 F internal /50/ /3300 BTU 5.1A/7.6A 16.4/20.1 A 38 kg/83.79 lbs 825W/960W Large Wallmount Air Conditioners Part No. Rated Dimensions Useful cooling Rated Starting Weight SK voltage inches mm capacity per DIN 3168 current current H W D H W D /50/ /4950 BTU 11.5A/12.0A 66.0A/37.0A 51 kg/ lbs 1400W/1450W 71

73 Ideal Cooling Solutions With... BLOWER SYSTEMS & FILTER FANS Rittal offers a comprehensive family of cooling solutions, especially designed for data communications applications. Our roofmounted blower systems integrate into our PS modular enclosures for effective forced air cooling. Versions are available in both 230 and 365cfm. The 230cfm model delivers effective cooling performance at a low noise level, while the 365cfm model is designed for high heat load applications. Both products use backward curved impeller blowers which provide higher airflow than traditional fan trays in densely packed enclosures. Rittal filter fans also provide an easy-toinstall and effective method of providing enclosure cooling when the allowable internal temperature is higher than the ambient temperature. C ONFIGURATION Blower system: Includes mounting hardware, 2" spacer bolt for raising standard roof and 9' cord/plug RAL 7044 (silk grey) Filter fan: Includes fan/filter louver system and mounting hardware RAL 7032 (pebble grey) Roof Blower Systems Accessories Part No. Air displacement Dimensions Voltage Power Noise Protective Mounting Used Thermostat Speed SK cfm at free (mm) (W) level category location with controller delivery H W D (dba) NEMA 1 with DK vented roof Roof 600x600 DK-PS NEMA 1 with DK vented roof Roof 600x800 DK-PS NEMA 1 with DK vented roof Roof 800x800 DK-PS NEMA 1 with DK vented roof Roof 600x600 DK-PS NEMA 1 with DK vented roof Roof 600x800 DK-PS NEMA 1 with DK vented roof Roof 800x800 DK-PS NEMA 1 with DK vented roof Roof 600x900 DK-PS Filter Fans Part No. Rating Dimensions Voltage Current Noise Outlet SK cfm 1 inches mm dba filter 50/60 Hz H W D 2 H W D / /50/ /.12A 46/ / /50/ /.23A 46/ / /50/ /0.24A 52/ / /50/ /.49A 54/ / /50/ /.70A 59/ /50/60 1.5/2.0A 75/ unimpeded airflow (includes filter and louver). 2 denotes depth filter fan extends into enclosure. 3 denotes UL Type 12, 230V, 24V DC is also available. 72

74 Designed To Cool High Heat Loads... SERVER FAN ASSEMBLY With today s high heat loads inside server enclosures, it is critical to use thermal management techniques which optimize enclosure ventilation. Having vented front and rear doors and a vented roof, Rittal s PS server cabinets provide such ventilation. Rittal s PS server fan assembly takes advantage of the front-to-rear airflow of most servers and allows the user to position the fan assembly in the most critical location within the cabinet. The powerful 220cfm high pressure fans feature a shallow depth chassis design and provide the ability to exhaust hot air out the rear of the enclosure at a dramatically higher rate than traditional roof mount fan trays. The result is cooler operating equipment, even with very high enclosure heat loads. C ONFIGURATION Rittal s PS server fan assembly provides a slim-line design and increased cooling for server applications. 2 fans per assembly (440cfm total) Includes 10 cord/plug, mounting hardware Optional fan expansion to total of four fans (220cfm per fan) Can be used for venting through roof by installing to PS system bars/dual brackets (not included) RAL 7035 (light grey) RAL 9005 (black) Server Fan Assembly Accessories Part No. Height(H) Width(W) Depth(D) cfm 2 Voltage Current Noise Additional Thermostat Speed mm mm mm 1 fan kit controller / /50/ A 59 dba / /50/ A 59 dba / /50/ A 59 dba Depth of extension from enclosure door into enclosure. 2 Free air delivery. 73

75 Technical Drawings QuickRack Network Cabinets W D X 20.0 H D D2 D1 21 Y C (i.l.) C W2 W1 W 2 Part No. QR Part No. QR Dimensions Inside cabinet Width Height with without inches mm.dimension C of glass door X of glass door Y sidewalls sidewalls H W D H W D inches mm inches mm inches mm QuickRack Roof Dimensions Width x depth Outside Width without Width inside frame Outside Inside frame Inside frame width inches sidewalls inches uprights inches depth inches posts inches roll-form inches W W1 W2 D D1 D x x x

76 Technical Drawings PS Perfect System Enclosures W x 25 = H a b c x 25 = d 30 D x 25 = x 25 = 675 i.l i.l Grey PS Cabinets Part No. DK Part No. DK U Dimensions a b c d with without inches mm sidewalls sidewalls H W D H W D "/1175mm 43.8"/1112mm 1.7"/43mm 42.3"/1075mm "/1175mm 43.8"/1112mm 1.7"/43mm 42.3"/1075mm "/1175mm 43.8"/1112mm 1.7"/43mm 42.3"/1075mm "/1775mm 67.4"/1712mm 2.6"/67mm 65.9"/1675mm "/1775mm 67.4"/1712mm 2.6"/67mm 65.9"/1675mm "/1775mm 67.4"/1712mm 2.6"/67mm 65.9"/1675mm "/1975mm 75.3"/1912mm 3"/75mm 73.8"/1875mm "/1975mm 75.3"/1912mm 3"/75mm 73.8"/1875mm "/1975mm 75.3"/1912mm 3"/75mm 73.8"/1875mm "/2175mm 83.1"/2112mm 3.3"/83mm 81.7"/2075mm "/2175mm 83.1"/2112mm 3.3"/83mm 81.7"/2075mm "/2175mm 83.1"/2112mm 3.3"/83mm 81.7"/2075mm Black PS Cabinets Part No. U Dimensions a b c d DK inches mm H W D H W D "/1975mm 75.3"/1912mm 3"/75mm 73.8"/1875mm "/1975mm 75.3"/1912mm 3"/75mm 73.8"/1875mm "/1975mm 75.3"/1912mm 3"/75mm 73.8"/1875mm "/2175mm 83.1"/2112mm 3.3"/83mm 81.7"/2075mm 75

77 Technical Drawings VarioRack Network Cabinets W 19 x 25 =475 (11 x 25 =275) x25= i.l H b cx25=d ex375 a 525 (325) (518) 850 (650) Part No. DK with sidewalls Part No. DK without sidewalls U Dimensions a b c d e inches mm H W D H W D "/1730mm 63"/1602mm 2.5"/63mm 62"/1575mm.08"/2mm "/1730mm 63"/1602mm 2.5"/63mm 62"/1575mm.08"/2mm "/1930mm 71"/1802mm 2.8"/71mm 69.9"/1775mm.12"/3mm "/1930mm 71"/1802mm 2.8"/71mm 69.9"/1775mm.12"/3mm 76

78 Technical Drawings BasicRacks Part No. BR Dimensions a b inches mm H W D H W D "/450.9mm 18.31"/465.1mm "/450.9mm 18.31"/465.1mm "/450.9mm 18.31"/465.1mm "/450.9mm 18.31"/465.1mm a Flange edge to flange edge b Mounting hole to mounting hole Data Racks Part No. DK U a b U x "/1499.5mm 54.4"/1381.5mm "/1721.8mm 63.1"/1603.8mm "/1899.5mm 70.1"/1781.5mm "/2121.8mm 78.9"/2003.8mm I.L.450 a b mm spacing min. 150-max

79 Technical Drawings RiPatch Detail 'A' Fixing Positions for Cable Management Arms on Pitch = Pitches of = U Panel Space = Pitches of = Side View Min Max Front View Rear View 2 Pitches of 150 = Pitches of 100 = SQ. Holes Detail 'A' Open Area Bottom View Part No. DK U H W D " 24" 18" 78

80 Technical Drawings QuickBox Enclosures /400/ HE h-7 H HE h h h3 I.L.h A X h /330/ /350/550 Part No. QB with viewing door Part No. QB with solid door U SU Height Width Depth h1 h2 h3 h "/362mm 23.62"/600mm 23.62"/600mm 9.53"/242mm 9.21"/234mm 10.51"/267mm 10.75"/273mm "/495mm 23.62"/600mm 23.62"/600mm 14.76"/375mm 14.45"/367mm 15.75"/400mm 15.98"/406mm "/628mm 23.62"/600mm 23.62"/600mm 20.00"/508mm 19.72"/501mm 21.02"/534mm 21.26"/540mm "/762mm 23.62"/600mm 23.62"/600mm 25.28"/642mm 24.96"/634mm 26.26"/667mm 26.50"/673mm "/895mm 23.62"/600mm 23.62"/600mm 30.51"/775mm 30.20"/767mm 31.50"/800mm 31.73"/806mm "/1028mm 23.62"/600mm 23.62"/600mm 35.75"/908mm 35.47"/901mm 36.77"/934mm 37.00"/940mm AE 2-Part Enclosures L Lm H Part No. U Dimensions DK inches mm H W D H W D

81 Technical Drawings EL 3-Part Enclosures 27 x 25= x 25= x 25= H HE b a 275 c 25 Max. installation depth 364mm 100 Part No. DK Available space Dimensions a b c inches mm H W D H W D U "/407mm 17"/432mm 4"/103.5mm U "/674mm 27.5"/699mm 5"/124.5mm U "/941mm 38"/965mm 5.2"/133mm EL 3-Part Enclosures NEMA 12 Part No. DK U Dimensions inches mm H W D H W D PS Server/Mass Storage Cabinets Note: For individual cabinet dimensions, please refer to pages Depth Adjustable Rail Location Top View Front View Left Side View (Side Panel Excluded) Rear View 80

82 Technical Drawings VR Server/Mass Storage Cabinets Front 14.5 (0.57") Rail position at delivery nom Top view, note 1 side cover shown fitted 850.0mm M12 jacking feet with locknuts. Full size detail of rear door insert. Part No. U Approx. outside dimensions DK inches mm H W D H W D ISP Enclosures Depth Adjustable Rail Location Front/Rear View Left Side View (Side Panel Excluded) Note: For individual cabinet dimensions, please refer to page 50. Seismic-Rated Cabinets Part No. 36U DK inches mm H W D H W D U

83 Technical Appendix NEMA, UL And CSA Standards Enclosure NEMA UL CSA rating National Electrical Underwriters Canadian Standards Manufacturers Laboratories, Inc. Association Association (NEMA 250) (UL 50 and 508) (C22.2 No.94-M91) Type 1 Enclosures are intended for Indoor use primarily to provide General purpose enclosure. indoor use primarily to provide a protection against contact with Protects against accidental degree of protection against the the enclosed equipment and contact with live parts. contact with the enclosed against a limited amount of falling equipment. dirt. Type 2 Enclosures are intended for Indoor use to provide a degree Indoor use to provide a degree indoor use primarily to provide a of protection against contact with of protection against dripping and degree of protection against the enclosed equipment and light splashing of noncorrosive limited amounts of falling water against a limited amount of falling liquids, and falling dirt. and dirt. dirt. Type 3 Enclosures are intended for Outdoor use to provide a degree Indoor or outdoor use to outdoor use primarily to provide of protection against windblown provide a degree of protection a degree of protection against dust and windblown rain; against rain, snow, and rain, sleet, windblown dust, and undamaged by the formation of windblown dust; undamaged by damage from external ice ice on the enclosure. the external formation of ice on formation. the enclosure. Type 3R Enclosures are intended for Outdoor use to provide a degree Indoor or outdoor use to outdoor use primarily to provide of protection against falling rain; provide a degree of protection a degree of protection against undamaged by the formation of against rain, snow; undamaged by rain, sleet, and damage from ice on the enclosure. the external formation of ice on external ice formation. the enclosure. Type 4 Enclosures are intended for Indoor or outdoor use to Indoor or outdoor use to indoor and outdoor use primarily provide a degree of protection provide a degree of protection to provide a degree of protection against falling rain, splashing against rain, snow, and against windblown dust and rain, water, and hose-directed water; windblown dust, splashing and splashing water, hose-directed undamaged by the formation of hose-directed water; undamaged water, and damage from external ice on the enclosure. by the external formation of ice ice formation. on the enclosure. Type 4X Enclosures are intended for Indoor or outdoor use to Indoor or outdoor use to indoor and outdoor use primarily provide a degree of protection provide a degree of protection to provide a degree of protection against falling rain, splashing against rain, snow, and against corrosion, windblown water, and hose-directed water; windblown dust, splashing and dust and rain, splashing water, undamaged by the formation of hose-directed water; undamaged hose-directed water, and damage ice on the enclosure; resists by the external formation of ice from external ice formation. corrosion. on the enclosure; resists corrosion. Type 6 Enclosures are intended for Indoor or outdoor use to Indoor or outdoor use to indoor and outdoor use primarily provide a degree of protection provide a degree of protection to provide a degree of protection against entry of water during against entry of water during against hose-directed water, the temporary submersion at a temporary submersion at a entry of water during occasional limited depth; undamaged by the limited depth; undamaged by the temporary submersion at a formation of ice on the enclosure. formation of ice on the enclosure. limited depth, and damage from external ice formation. Type 12 Enclosures are intended for Indoor use to provide a degree Indoor use primarily to provide a indoor use primarily to provide a of protection against dust, dirt, degree of protection against degree of protection against fiber flyings, dripping water, and circulating dust, lint, fibers, and circulating dust, falling dirt, and external condensation of non- flyings; dripping and light dripping non-corrosive liquids. corrosive liquids. splashing of noncorrosive liquids; not provided with knockouts. Type 13 Enclosures are intended for Indoor use to provide a degree Indoor use primarily to provide a indoor use primarily to provide a of protection against lint, dust degree for protection against degree of protection against seepage, external condensation circulating dust, lint, fibers, and dust, spraying water, oil and and spraying of water, oil, non- flyings; seepage and spraying of non-corrosive liquids. corrosive liquids. noncorrosive liquids including oils and coolants. Reprinted with permission from National Electrical Manufacturers Association, Underwriters Laboratories, Inc., and Canadian Standards Association. 82

84 Foamed-In-Place Gasket The foamed-in-place gasket is a thixotropic, two component modified polyurethane resin system. The gasket, being of a closed cell design, is excellent where very low water absorption is required. Other features of the gasket include: 1. Superior resilience, excellent compression recovery, provides a better seal. 2. Excellent adhesion to many substrates. 3. No seams or joints to leak-continuous bead. 4. Normal operating temperature of polyurethane foamed-inplace gasket is -40 C to +60 C (-40 F to +140 F). The polyurethane gasket provides excellent protection against the following chemicals: Animal and vegetable oils Acrylates Alkyd resins Hydrocarbon solvents Buty acetate Diacetone alcohol Epoxide oils Epoxy resins Epoxy esters Heptane Mineral oils Polyamide resins Polymeric plasticizers Turpentine Xylene Toluene Mehanol Propanol For additional applications not listed here, contact the Rittal Technical Hotline at Shock And Vibration In many locations, sensitive electric and electronic equipment must often be protected against mechanical influences. This is especially important for equipment that is part of the infrastructure. As the world's largest enclosure manufacturer, Rittal has focused on the protection of electric and electronic equipment in enclosures to provide the best possible security against shock and vibration (such as in earthquakes). Dynamic stress can be divided into: Short-term stress Shock conditions in shelters and machines Earthquakes Long-term stress Stationary operation (machines in vicinity) Transport Intermittent disturbances (e.g. when generators start or stop) To date such vibration tests have been performed by: University of Bristol, England 3-axis vibration platform, 6 of freedom Technical University of Berlin, Germany 1-axis vibration platform, horizontal or vertical These institutes performed tests in accordance with the following specifications: Bellcore Technical Reference TR-NWT ANSI/IEEE Std ANSI/IEEE Std Parts of IEC 68 Please contact your local Rittal representative for more information or details on specific applications. Vibration can be damaging to both the functioning and the mounting of equipment in enclosures. It is possible to prevent vibration or achieve targeted damping when the inherent frequencies and types of vibration of an enclosure under stress are known. Rittal has developed two retrofit kits for enclosures to meet shock and vibration damping requirements; each condition requires a different approach. The shock-damping retrofit kit consists of rigid components because stiffening measures provide the best protection against shocks. The vibrationdamping retrofit kit consists of flexible components which damp vibration. This flexible solution is the best way to damp vibrations with harmonic or periodic disturbances of approximately 15Hz and higher. For more information, contact the Rittal Technical Hotline

85 19" Rails/Shelf Installation Shelf mounting surface PS Network And VR Network Rails 24" and 32" (W) PS and 32" (W) VR cabinets only. Rails are fully adjustable. Shelf installation: no kit required Shelf Part Nos.: 7143, 7144, 7145, Come with mounting hardware (32"/34" D). Telescoping slides Part Nos. (optional): 7051, 7061, 7081, " mount surface 19" mount surface Install kit mounting surface VR Network And VR Server Cabinets All 24" (W) VR cabinets. Rails are partially adjustable. Shelf installation: With VR rails front and rear: (650mm D) (850mm D) With VR rails in front:(vr server cabinet) (adapter kit) * Note: Other partial height VR rails can also be used. *No adaptor kit required. Shelf Part Nos.: 7143, 7144, 7145, Comes with mounting hardware (34" D) Telescoping slides Part Nos. (optional): 7051, 7061, 7081, 7161 Server Rails PS server rails are fully adjustable on systems chassis. Shelf installation: VR server: DK 7085 shelf installation kit for VR servers PS server: DK 4544 shelf installation kit for PS servers Adjustable mounting rails for 19" rackmount Shelf Assembly Instructions Equipment Shelves Part No. Dimensions inches mm H D H D Tools Required Cordless Drill (> 12 Volt) #3 Phillips Bit 4mm Allen Wrench 10mm Wrench or 10mm Socket with Ratchet Handle Assembly Notes 1. Shelves are attached to both front and rear 19" mounting rails. 2. Installation hardware is included with each shelf. Parts will be left after shelf is installed. 3. Rails positioned for a 12" (D) shelf will also support a 16", 20" or 24" (D) shelf. Rails positioned for a 16" (D) shelf will also support the next two deeper shelves, etc. 4. Approximate times: Position 19" mounting rails 15 min. Install shelf 5 min. Installation 1. Use a shelf to determine correct positions for front and rear rails. Rails are either secured directly to horizontal system chassis or to lateral top and bottom brackets. If rails are secured to chassis, use the drill and #3 phillips bit to remove self-tapping screws, reposition rails and reinsert screws. If supported on brackets, use the 10mm wrench or socket and reposition entire rail assembly. 2. Install four (4) large allen head bolts (from hardware bag) into shelf support cylinders. 3. Determine height of shelf and install the first support cylinder into the round hole on the rear flange of the rail (behind large square hole). Notch on the cylinder and drive head of bolt face into cabinet. Secure on opposite side of flange with slide nut ( C shaped fastener). Repeat for remaining three (3) cylinders on each rail. 4. Place shelf over cylinder bolts. Cutouts on shelf sides will fit over notches on cylinders. Slide shelf forward so small part of cutout is over cylinder notch. 5. Secure shelf with long sheet metal screw (in shelf hardware bag). Drive screw through shelf and behind cylinder. 84

86 Shelf Selection Guide 1. Select chart based on the type of cabinet you have, with or without 19" rails and if regular or heavy duty shelves are needed. 2. Select the width and depth of the cabinet you have. 3. Select style of shelf (vented or solid, and color). 4. Match shelf with corresponding accessories based on requirements (fixed or telescopic). Regular Shelves Mounted on system chassis, fixed or on telescopic slides: DK-PS without 19" rails Cabinet W x D mm 600x x x x x x x x900 inches 24x24 24x32 24x36 24x40 28x36 28x40 32x32 32x36 Vented Shelf RAL Solid Shelf RAL N/A N/A N/A N/A Vented Shelf RAL N/A N/A Solid Shelf RAL N/A N/A N/A N/A Installation kit/sys. chassis Telescopic slides Above shelves indicate largest possible shelf that can be used, shorter shelves can also be used if required. Remember, when using shorter shelf you must use corresponding telescopic slide. For RAL 7035 components, replace last 3 digits with 035. Heavy Duty Shelves Mounted on system chassis, fixed or on telescopic slides: DK-PS without 19" rails Cabinet W x D mm 600x x x x x x x x900 inches 24x24 24x32 24x36 24x40 28x36 28x40 32x32 32x36 Vented Shelf RAL Solid Shelf RAL7032 N/A N/A N/A N/A N/A N/A N/A N/A Vented Shelf RAL Solid Shelf RAL7035 N/A N/A N/A N/A N/A N/A N/A N/A System chassis Telescopic slides Above shelves indicate largest possible shelf that can be used, shorter shelves can also be used if required. Remember, when using shorter shelf you must use corresponding telescopic slide. Regular Shelves 19" rackmount, fixed or on telescopic slides: DK-PS, PS servers, ISP cabinets with 19" rails Cabinet W x D mm 600x x x x x x x x900 inches 24x24 24x32 24x36 24x40 28x36 28x40 32x32 32x36 Vented Shelf RAL N/A N/A N/A N/A N/A Vented Shelf RAL / / / / / ** ** ** ** ** Vented Shelf RAL Telescopic slides N/A N/A N/A N/A Support rails* * Required only in PS server and ISP cabinets. ** RAL 9005 (Cool Black) Above shelves indicate largest possible shelf that can be used, shorter shelves can also be used if required. Remember, when using shorter shelf you must use corresponding telescopic slide. 85

87 Shelf Selection Guide Continued Regular Shelves Mounted on system chassis, fixed or on telescopic slides: DK-VR, VR server with 19" rails Cabinet W x D mm 600x x x850 inches 24x26 24x34 32x34 Vented Shelf RAL7035 N/A N/A N/A 12"/300mm deep shelf "/400mm deep shelf "/500mm deep shelf "/600mm deep shelf N/A */ */ Installation kit ** ** N/A Support rails *** *** N/A 12"/300mm deep slides "/400mm deep slides "/500mm deep slides "/600mm deep slides N/A * is RAL 7032 (pebble grey) ** Necessary for fixed and telescopic shelf installation in 24" wide DK-VR and VR servers. *** Only required in 24"/600mm wide DK-VRs and VR servers. Heavy Duty Shelves Mounted on system chassis, fixed installation only: DK-VR, VR server without 19" rails Cabinet W x D mm 600x x x850 inches 24x26 24x34 32x34 Vented Shelf RAL * System chassis Support rails N/A N/A N/A * will also work in a 24" wide DK-VR or VR server with 19" rails, as long as rails are in front/rear most position. Heavy Duty Shelves Mounted on system chassis, fixed installation only: DK-VR, VR server with 19" rails Cabinet W x D mm 600x x x850 inches 24x26 24x34 32x34 Vented Shelf RAL7035 N/A N/A System chassis N/A N/A N/A Support rails N/A N/A N/A * New VR heavy duty shelves mounts directly on top of system chassis. Additional Powerstrip Part Numbers Part No. Description Power strip, 6 REC., 15A/15A, USA, 120V, 15' cord, 19" rackmount, RAL Power strip, 6 REC., 15A/15A, USA, 120V, 6' cord w/ twist lock plug, 19" rackmount, RAL Power strip, 6 REC., 15A/15A, USA, 120V, 15' cord w/ twist lock plug, 19" rackmount, RAL Power strip, 6 REC., 15A/15A, USA, 120V, 6' cord, 19" rackmount, w/o on/off-switch, RAL Power strip, 6 REC., 15A/15A, USA, 120V, 15' cord, 19" rackmount, RAL Power strip, 6 REC., 15A/15A, USA, 120V, 6' cord w/ twist lock plug, 19" rackmount, RAL Power strip, 6 REC., 15A/15A, USA, 120V, 15' cord w/ twist lock plug, 19" rackmount, RAL Power strip, 6 REC., 15A/15A, USA, 120V, 6' cord, 19" rackmount, w/o on/off-switch, RAL Power strip, 6 REC., 15A/20A, USA, 120V, 6' cord w/ twist lock plug, 19" rackmount, RAL Power strip, 6 REC., 15A/20A, USA, 120V, 15' cord w/ twist lock plug, 19" rackmount, RAL Power strip, 6 REC., 15A/20A, USA, 120V, 6' cord, 19" rackmount, w/o on/off-switch, RAL Power strip, 6 REC., 20A/20A, USA, 120V, 15' cord, 19" rackmount, RAL Power strip, 6 REC., 20A//20A, USA, 120V, 6' cord w/ twist lock plug, 19" rackmount, RAL Power strip, 6 REC., 20A/20A, USA, 120V, 15' cord w/ twist lock plug, 19" rackmount, RAL Power strip, 6 REC., 20A/20A, USA, 120V, 6' cord, 19" rackmount, w/o on/off-switch, RAL Power strip, 6 REC., 15A/15A, USA, 120V, 15' cord, 19" rackmount, w/ surge protection, RAL Power strip, 6 REC., 15A/15A, USA, 120V, 6' cord w/ twist lock plug, 19" rackmount, w/ surge protection, RAL Power strip, 6 REC., 15A/15A, USA, 120V, 15' cord w/ twist lock plug, 19" rackmount, w/ surge protection, RAL

88 Powerstrip Part Numbers Continued Part No. Description Power strip, 6 REC., 15A/15A, USA, 120V, 6' cord, 19" rackmount, w/ surge protection, w/o on/off-switch, RAL Power strip, 8 REC., 15A/15A, USA, 120V, 15' cord, 2' frame mount, RAL Power strip, 8 REC., 15A/15A, USA, 120V, 6' cord w/ twist lock plug, 2' frame mount, RAL Power strip, 8 REC., 15A/15A, USA, 120V, 15' cord w/ twist lock plug, 2' frame mount, RAL Power strip, 8 REC., 15A/15A, USA, 120V, 6' cord, 2' frame mount, w/o on/off-switch, RAL Power strip, 8 REC., 15A/20A, USA, 120V, 15' cord w/ twist lock plug, 2' frame mount, RAL Power strip, 8 REC., 15A/20A, USA, 120V, 6' cord, 2' frame mount, w/o on/off-switch, RAL Power strip, 8 REC., 20A/20A, USA, 120V, 15' cord, 2' frame mount, RAL Power strip, 8 REC., 20A/20A, USA, 120V, 6' cord w/ twist lock plug, 2' frame mount, RAL Power strip, 8 REC., 20A/20A, USA, 120V, 15' cord w/ twist lock plug, 2' frame mount, RAL Power strip, 8 REC., 20A/20A, USA, 120V, 6' cord, 2' frame mount, w/o on/off-switch, RAL Power strip, 8 REC., 15A/15A, USA, 120V, 15' cord, 2' frame mount, w/ surge protection, RAL Power strip, 8 REC., 15A/15A, USA, 120V, 6' cord w/ twist lock plug, 2' frame mount, w/ surge protection, RAL Power strip, 8 REC., 15A/15A, USA, 120V, 15' cord w/ twist lock plug, 2' frame mount, w/ surge protection, RAL Power strip, 8 REC., 15A/15A, USA, 120V, 6' cord, 2' frame mount, w/ surge protection, w/o on/off-switch, RAL Power strip, 15 REC., 15A/15A, USA, 120V, 15' cord, 4' frame mount, RAL Power strip, 15 REC., 15A/15A, USA, 120V, 6' cord w/ twist lock plug, 4' frame mount, RAL Power strip, 15 REC., 15A/15A, USA, 120V, 15' cord w/ twist lock plug, 4' frame mount, RAL Power strip, 15 REC., 15A/15A, USA, 120V, 6' cord, 4' frame mount, w/o on/off-switch, RAL Power strip, 15 REC., 15A/20A, USA, 120V, 15' cord, 4' frame mount, RAL Power strip, 15 REC., 15A/20A, USA, 120V, 15' cord w/ twist lock plug, 4' frame mount, RAL Power strip, 15 REC., 15A/20A, USA, 120V, 6' cord, 4' frame mount, w/o on/off-switch, RAL Power strip, 16 REC., 20A/20A, USA, 120V, 15' cord, 4' frame mount, RAL Power strip, 16 REC., 20A/20A, USA, 120V, 6' cord w/ twist lock plug, 4' frame mount, RAL Power strip, 16 REC., 20A/20A, USA, 120V, 15' cord w/ twist lock plug, 4' frame mount, RAL Power strip, 16 REC., 20A/20A, USA, 120V, 6' cord, 4' frame mount, w/o on/off-switch, RAL Power strip, 15 REC., 15A/15A, USA, 120V, 15' cord, 4' frame mount, w/ surge protection, RAL Power strip, 15 REC., 15A/15A, USA, 120V, 6' cord w/ twist lock plug, 4' frame mount, w/ surge protection, RAL Power strip, 15 REC., 15A/15A, USA, 120V, 15' cord w/ twist lock plug, 4' frame mount, RAL Power strip, 15 REC., 15A/15A, USA, 120V, 6' cord, 4' frame mount, w/ surge protection, w/o on/off-switch, RAL Power strip, 24 REC., 15A/15A, USA, 120V, 15' cord, 6' frame mount, RAL Power strip, 24 REC., 15A/15A, USA, 120V, 6' cord w/ twist lock plug, 6' frame mount, RAL Power strip, 24 REC., 15A/15A, USA, 120V, 15' cord w/ twist lock plug, 6' frame mount, RAL Power strip, 24 REC., 15A/15A, USA, 120V, 6' cord, 6' frame mount, w/o on/off-switch, RAL Power strip, 24 REC., 15A/20A, USA, 120V, 15' cord, 6' frame mount, RAL Power strip, 24 REC., 15A/20A, USA, 120V, 6' cord w/ twist lock plug, 6' frame mount, RAL Power strip, 24 REC., 15A/20A, USA, 120V, 15' cord w/ twist lock plug, 6' frame mount, RAL Power strip, 24 REC., 15A/20A, USA, 120V, 6' cord, 6' frame mount, w/o on/off-switch, RAL Power strip, 24 REC., 20A/20A, USA, 120V, 15' cord, 6' frame mount, RAL Power strip, 24 REC., 20A/20A, USA, 120V, 6' cord w/ twist lock plug, 6' frame mount, RAL Power strip, 24 REC., 20A/20A, USA, 120V, 15' cord w/ twist lock plug, 6' frame mount, RAL

89 Climate Control General Information The Need For Climate Control When the expense of electronic and electrical components and the costly implications of a system s down time are considered, it is important that all reasonable steps are taken to ensure that steady and reliable performance of a system continues. This should in almost all circumstances include climate control cooling and/or heating. The Purpose Of Cooling Electronic and electric equipment often generate a great deal of heat during operation. Frequently located in hostile environments, the equipment may also encounter the additional problem of not having safe, clean air available to dissipate unwanted heat. Such adverse conditions affect the performance and the life expectancy of electrical/electronic system components. Rittal cooling devices are precisely designed to solve the problems of internal heat build-up above component tolerances, excessive ambient temperatures, moisture and contaminant laden atmospheres and corrosive environments, which can affect sensitive electronic equipment. A little time and effort spent early in the design process can save a great deal of trouble and expense later by preventing the need to retrofit with proper cooling devices in the field during a down time situation. Information Needed For Climate Control Selection The following information should be on hand to properly size cooling products. (1) Heat to be dissipated (Watts) by the electrical components inside the enclosure (2) Maximum temperature expected outside enclosure ( F) (3) Maximum allowable internal enclosure temperature ( F) (4) Enclosure dimensions Request For Climate Control Application Information To: Rittal Corporation Tel. (937) Rittal Place FAX (937) Springfield, Ohio climate-cntl@rittal-corp.com Climate Control Group Applications Engineer Date: Page 1 of: Company Address: Contact Name: Telephone: Project Name/Number Title: Fax: Application Questionnaire 1. What is the maximum ambient air temperature? F 2. What is the maximum allowable internal enclosure temperature? F 3. What is the size and mounting style of the enclosure to be heated or cooled? H W D Mounting: (freestanding, wall, suited) 4. a: What is the measured temperature difference between the outside and inside of the enclosure with the door closed and any vents or openings sealed F or b: How many Watts or BTUs of heat is given off by the equipment inside the enclosure? 5. At what voltage and frequency is the climate control device required to operate? Voltage and Hz 6. Is chilled water available for use in conjunction with an air/water heat exchanger? If no, is a chilled water cooling system a viable option? 7. Is there a specific NEMA or approval rating that the climate control equipment needs to comply with? NEMA UL CE CSA 8. Estimated project commercialization date 9. Estimated annual climate control product volume units/year 10. Special requirements or considerations 88

90 Three Basic Cooling Methods Climate Control General Selection Information When selecting a cooling method there are three types to consider. (1) Passive Ventilation - If there is only a minimal heat gain in your circumstance and the ambient air is relatively cool and clean, then the use of louvers or grilles with filters can be effective. This method, however, usually provides less cooling effect than is necessary with today s components. The temperature rise within a sealed enclosure is seen in Figure 2. (2) Forced Convection Air Cooling - If the installation will be in a clean, non-hazardous environment with an acceptable ambient (outside the enclosure) temperature range, a simple forced-air cooling system utilizing outside air is usually adequate. Combined with an air filter, such devices generally meet the heat removal needs of typical electronic equipment and many electrical applications (Fig. 1). Examples of forced convection air cooling are filter fans, pagoda roof fans, fan trays, and blowers of various types. FIGURE 1 - Forced Covection Method Outlet louvers Ambient Air with Heat Load Ambient Air Fan or Blower Cabinets Pressurized System - pushes air through enclosure Filter Fan Airflow Pagoda Roof Fan Airflow Fans And Blowers Can Be Used To Pressurize (Preferred) Or Exhaust Cabinet Air. The Ambient Air Should Be Filtered Before It Enters The Cabinet. (3) Closed-Loop Cooling - In harsh environments involving high temperatures, wash-down requirements, heavy particulate matter or the presence of chemicals capable of damaging components (NEMA 4 or 12 environments), ambient air must be kept out of the enclosure. Closed-loop cooling consists of two separate circulation systems. One system, sealed against the ambient air, cools and recirculates the clean cool air throughout the enclosure. The second system uses ambient air or water to remove and discharge the heat. Examples of closed-loop cooling equipment employed with electronics and process controls are heat exchangers and air conditioners. Blowers are used in higher static pressure applications (when internal equipment is densely packed), and are at maximum efficiency when operating near their peak static pressure. Air Conditioner Airflow Advanced Thermal Modeling (4) Rittal also offers, on a fee basis, advanced thermal modeling using state-of-the-art CFD (computerized fluid dynamics) software. For additional information on improving your system reliability and cost through thermal analysis and testing, please contact Rittal. 89

91 Climate Control Sizing Rittal offers four different methods to cool an enclosure, and one to warm an enclosure. To cool an enclosure, the following must be known: Size of the enclosure and exposed enclosure surface (A= m 2 ) = A Ambient temperature outside of the enclosure (Tu) Required temperature inside the enclosure (Ti) Difference = T Heat transfer coefficient (5.5 W/m 2 K sheet steel 3.5 W/m 2 K plastic) = k Heat loss (heat build up from the installed components installed) = Qv Solution of equation will give you required cooling capacity = Qe To calculate the exposed surface area of an enclosure, apply the following: (All values are metric) 1. Single enclosure, freestanding A = 1.8 x H x (W + D) x W x D 2. Single enclosure, against a wall A = 1.4 x W x (H + D) x D x H 3. First/last enclosure of a suite A = 1.4 x D x (H + W) x W x H 4. First/last against a wall A = 1.4 x H x (W + D) x W x D 5. Enclosure within a suite A = 1.8 x W x H x W x D + D x H 6. Enclosure within suite/wall A = 1.4 x W x (H + D) + D x H 7. Enclosure within suite/wall/roof A = 1.4 x W x H x W x D + D x H Example Of Air Conditioning Sizing: PS 4808 freestanding (2 x.8 x.8) 2000 x 800 x 800mm = 2 x.8 x.8m A = 1.8 x 2 x (1.6) x.8 x.8 (A= 6.6) Ambient = 95 F / 35 C Required internal = 88 F / 31 C Heat transfer coefficient = 5.5 Heat loss = 650 watts / 2210 BTU Required cooling = A x T x k + Qv (heat loss) 6.6 x 4 x = 795 watts / 273 BTU Locate the air conditioner in the Rittal catalog that would best fit this application, confirm with performance diagram. Sizing An Air to Water Heat Exchanger: Qe = A x T x k + Qv Confirm with performance diagram, noting temperature of cooling water. Sizing An Air to Air Heat Exchanger: qw (required thermal capacity) = Qv - A x T x k T Sizing a Filter Fan: V (volume) = f x Qv T (f = altitude above sea level in meters). Sizing an Enclosure Heater: QH (Required heat) = A x T x k Other Factors To Consider Include: NEMA requirements Voltage available Harshness of environment (corrosive gases) Maintenance intervals Space available on enclosure Conversions Length Multiply By 1 inch = 25.4mm? x 25.4 = mm 1 inch = 2.54cm? x 2.54 = cm 1 foot = 304.8mm? x = mm 1 foot = 30.4cm? x 30.4 = cm 1 foot =.304m? x.304 = m 1mm =.039 inch? x.039 = inch 1cm =.394 inch? x.394 = inch 1m = inch? x = inch 1m = 3.28 ft.? x 3.28 = ft. 1m = 1.09 yds.? x 1.09 = yds. 1 lb =.454 kg? x.454 = kg 1 kg = 2.2 lbs? x 2.2 = lbs 1 BTU =.29 watts? x.29 = watts 1 watt = BTU? x = BTU 1cfm =.591 cmh? x.591 = cmh 1 cmh = 1.692cfm? x = cfm 1 newton =.225 lb? x.225 = lb 1 lbf = 4.45 newton? x 4.45 = newton Metal Gauge Thickness Gauge Inches Metric 7 gauge gauge gauge gauge gauge gauge gauge gauge gauge gauge gauge

92 a z 19 19" component shelves-3-part EL 44 19" component shelves-ps 18 19" component shelves-qb 40 19" component shelves-qr 12 19" component shelves-vr keyboard drawer-ps keyboard drawer-vr rackmount fans-qb 40 19" rails-qr 12 19" routing panel-ps 23 19" routing panel-qr 12 19" support rails-vr 28 A AE 2-Part enclosures AE 2-Part technical drawings 79 Air conditioners 71 B Base 11 BasicRack technical drawings 77 BasicRacks 33 Baying kit 13 Baying kit-ripatch 36 Baying tubes-ripatch 36 Blower systems 72 Booster-CMC 65 C Cable base-vr 29 Cable clamp strap-cmc 65 Cable collecting bar-cmc 65 Cable collecting rails-qb 40 Cable collecting rails-qr 13 Cable collecting strip-ps 23 Cable collecting strip-vr 30 Cable entry panel-3-part EL 44 Cable entry roof panel-ps 20 Cable fingers-ripatch 36 Cable guide rings-ps 23 Cable guide rings-vr 30 Cable management module kit-cmc 66 Cable management module-cmc 66 Cable routing duct-ps 21 Cable ties for PS quick-assembly system 23 Captive nuts 24 Casters-PS 21 Certification standards 82 Chip card reader-cmc 70 Climate control technical information Climate control-ps 22 Component shelves-ps 18 Computer Multi Control (CMC) overview Computer Multi Control Connector kit-cmc 64 Connection cable-cmc 66 D Data Rack technical drawings 77 Data Racks 34 E EL 3-Part enclosures EL 3-Part technical drawings 80 Education cabinets 53 Entry sensor-cmc 68 Ergoform-S handle-cmc 69 Extended plinth infill kit 36 Extension cable-cmc 66 F Fan expansion kit-3-part EL 44 Fan trays-qr 12 Filter fans 72 Foamed-in-place gasket 90 Freestanding cabinets 5-30 G Ground bus-2-part AE 42 H Handle for component shelves-ps 19 Hygro/Thermo sensor-cmc 68 I Installation kit for 110 lbs DK component shelves 18 Installation bolts 24 Installation brackets 20 Installation kit for component shelves 11 Interconnecting frames-vr 29 Interconnecting kit-ps 23 ISP (Internet Service Provider) cabinets 50 ISP cabinet technical drawings 81 Courtesy of Steven Engineering, Inc.! 230 Ryan Way, South San Francisco, CA ! Main Office: (650) ! Outside Local Area: (800) ! 91

93 K K-12 cabinets 53 Keypad lock-cmc 70 L Leveling feet with swivel base 21 M Magnetic card reader-cmc 70 Mass storage cabinets Mini Ergoform-S handle 44 Mounting bracket-ps 20 N Network cabinets overview 5-6 Network racks overview Nuts/screws-PS 24 P Plastic thumb-turn handle-2-part AE 42 Plinths and cable bases-ps 20 Power cord-cmc 64 Power strips - additional Power strips kit 13 Power strips-2-part AE 42 Power strips-ps 24 Power strips-vr 29 Power supply-cmc 65 PS cabinets PS overview PS server cabinet technical drawings 80 PS server/mass storage cabinets PS technical drawings 75 Q Quick connecting wedge 23 QuickBox enclosures QuickBox technical drawings 79 QuickRack cabinets 9-13 QuickRack overview 7-8 QuickRack technical drawings 74 R Racks RiPatch racks 35 RiPatch technical drawings 78 Roof fan 22 Roof fan tray 22 Roof spacers-ps 20 Roofmounted blower system-ps 21 Roofmounted fan tray-vr 30 Row end side wall-ripatch 36 S Security inserts 42 Seismic cabinets Seismic cabinets technical drawings 81 Sensor cable-cmc 64 Server cabinets Server fan assembly 73 Shelf installation Shelf selection guide Shock and vibration Sidewalls 11 Smoke sensor-cmc 67 Space plinth-ripatch 34 Support rails-ps 19 Support rails-qr 12 Support rails-vr 28 Suppressor for fans-cmc 65 System chassis-ps 21 T Telescopic slides-ps 19 Telescopic slides-qb 40 Temperature sensor-cmc 67 Top cover cable guide tubes 36 Twin casters-qr 13 Twin casters-vr 28 V VarioRack cabinets VarioRack overview VarioRack technical drawings 76 Velcro cable straps-ps 23 Vented component shelves-ps 18 Vented component shelves-quickrack 11 Vented top cover-ripatch 35 Ventilated roof-ps 19 Vibration sensor-cmc 68 VR server cabinet technical drawings 81 VR server/mass storage cabinets 49 W Wallmount cabinets Wallmount cabinet overview Wallmounting brackets-2-part AE 42 Wallmounting brackets-3-part EL 44 Z Zone 4 cabinets

94 Part No. To Page No. Index Part No. Page No ,13,24, ,13,24, , , , ,44, ,41,42,43,44, ,42,44, , , , , , , , , ,40 Part No. Page No ,19, , ,27, , , , ,28,84, , ,23,47, ,19,28,40, ,11,17,19,28, 39,40, ,19,28,38, ,19, ,19, ,19, ,48,50,84, , , , , , ,11,17,19,27,28, 34,39,40,49,84, ,28,49, , , , ,40, ,9,10,12,18,40, , ,28, ,10,11,12,28,39, 40,53,84, ,17,18,27, ,10,11,12,28,34 39,40,47,48,49,53, ,84, Part No. Page No , ,18,32,34,38, 39,40,43, , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,66 Part No. Page No , , , , , ,24,29,41, ,29, ,29,42, ,29, ,29, , , , , , ,34 93

95 Part No. Page No , , , , ,34, ,34, ,34, , , , , , , , , ,39,53, ,39,53, ,39,53, ,39,53, ,39,53, ,39,53, ,53, ,53, ,53, ,53, ,53, ,53, ,39, ,39, ,39, ,39, ,39, ,39, ,40, ,39,40, ,53, ,53,74 Part No. Page No ,53, ,53, , , ,53, ,74, ,10, ,10, ,10, ,10, ,10, ,10, ,10, ,10, , , , ,30,58, ,30,58, ,43, ,43, ,43, , Part No. Page No ,47, , ,35,78 Part No. Page No ,35, ,35, , , , , , , ,43, ,84, ,17,22, ,17,22, ,17,22, , , , , , , ,41, ,41, ,41, , , ,27,30, ,27, , , , , ,27,29, , , , , ,74 94

96 Part No. Page No. Part No. Page No. Part No. Page No. Part No. Page No , , , , ,17, , , , ,17, , , , , ,27, , , ,47,48, ,21,47, , ,27, ,47, , , , ,27, , , ,53, ,27, , , , , ,9,53, ,9,53, ,9,53, ,33, , ,53, ,33, ,13, ,33, ,12, ,33, ,12, , , , , , , ,48,50, , , , , ,17, ,49, , , , , , , , ,47,48, ,17, , , , , , , ,17, , ,48,50, ,17, , , , ,17, , ,17,

97 Industrial Enclosure Systems 19 Electronic Components Enclosure Climate Control Busbar Power Distribution Data Communications & Networking Products Telco & Wireless Outdoor Enclosures In USA: Rittal Corporation One Rittal Place Springfield, OH Phone: (937) Fax: (937) Toll Free: Internet: In Canada: Rittal Systems Ltd Pacific Circle Mississauga, Ontario L5T 1V1 Toll Free: In México: Rittal, S.A. de C.V. Prolongación 5 de Mayo No. 29 Parque Industrial Naucalpan Naucalpan, México Phone: (525) Fax: (525) R HCG 4/01 15M HG #

Vertiv VR Rack 1.0 GENERAL

Vertiv VR Rack 1.0 GENERAL 1.1 SUMMARY Vertiv VR Rack Guide Specifications 1.0 GENERAL This specification defines the mechanical characteristics and requirements for the Vertiv VR Rack. A series of adaptive and scalable electronic

More information

PowerChain Management solutions. Enclosure Solutions

PowerChain Management solutions. Enclosure Solutions PowerChain Management solutions Enclosure Solutions Eaton Enclosures IT availability and reliability are critical corporate issues in today s demanding, mission-critical environments. For this reason,

More information

Knurr Miracel Server Rack

Knurr Miracel Server Rack Knurr Miracel Server Rack Knurr Server Racks are featured in these Scenarios: Scenario A 1-2 Rack page 8 Scenario C 3-6 Racks page 12 Scenario D 7-10 Racks page 14 Scenario E 10-30 Racks page 16 Scenario

More information

VERTIV VR RACK. Selection Guide

VERTIV VR RACK. Selection Guide VERTIV VR RACK Selection Guide VERTIV VR RACK Rapid Deployments Everywhere You Operate Standardize your deployments around the world and bring them online faster with the Vertiv VR rack. The Vertiv VR

More information

19" TiRAX cabinet system. from page 3. 19" NETcell cabinet system from page 31. Open 19" racks from page 43

19 TiRAX cabinet system. from page 3. 19 NETcell cabinet system from page 31. Open 19 racks from page 43 9" TiRAX cabinet system from page 9" NETcell cabinet system from page Open 9" racks from page Wall-mounting/stand-alone distribution systems from page 5 Wall-mounting enclosure systems from page 6 Air

More information

D-Net CABINETS. D-Net cabinets are a versatile racking system suitable for housing

D-Net CABINETS. D-Net cabinets are a versatile racking system suitable for housing D-Net CABINETS D-Net cabinets are a versatile racking system suitable for housing networking and various structured cabling components. D-Net Cabinets are manufactured in Taiwan in compliance with ISO9001:2000

More information

HCS Newsletter No. 43, Dated Thursday, 04 December, 2003 HCS DataLine Cabinets and Enclosures

HCS Newsletter No. 43, Dated Thursday, 04 December, 2003 HCS DataLine Cabinets and Enclosures HCS - Made in Turkey With Pride! HCS Newsletter No. 43, Dated Thursday, 04 December, 2003 HCS DataLine Cabinets and Enclosures HCS, the only Turkish manufacturer of state-of-the-art LAN cabling systems

More information

Rack Solutions RS-2. Free Standing Racks & Cabinets Wall Mount Racks, Cabinets, & Brackets Shelving Cable Management Accessories RS-5 RS-10 RS-12

Rack Solutions RS-2. Free Standing Racks & Cabinets Wall Mount Racks, Cabinets, & Brackets Shelving Cable Management Accessories RS-5 RS-10 RS-12 Rack Solutions Rack Solutions Rack Solutions Contents: RS-2 RS-5 RS-10 RS-12 RS-14 Free Standing Racks & Cabinets Wall Mount Racks, Cabinets, & Brackets Shelving Cable Management Accessories As a logical

More information

15U Wall-Mount Server Rack Cabinet - 20 in. Deep - Hinged

15U Wall-Mount Server Rack Cabinet - 20 in. Deep - Hinged 15U Wall-Mount Server Rack Cabinet - 20 in. Deep - Hinged Product ID: RK1520WALHM This 15U server or network rack cabinet lets you mount your EIA-310 compliant equipment to the wall, in a secure enclosure

More information

SYSTIMAX Rack and Cabinet Solution

SYSTIMAX Rack and Cabinet Solution SYSTIMAX Rack and Cabinet Solution The SYSTIMAX Rack and Cabinet Solution offer is designed for use in telecommunications equipment installations, providing our SYSTIMAX BusinessPartners and customers

More information

Featured Products - RU Marking Standard on Hoffman brand

Featured Products - RU Marking Standard on Hoffman brand : Open Frame Racks CHAPTER Open frame racks are versatile solutions for mounting hubs, switches, routers and servers. Easy access to all sides simplifies maintenance and updates. Solidly constructed, Pentair

More information

IT infrastructure Efficiency-boosting solutions. nextlevel. for data centre

IT infrastructure Efficiency-boosting solutions. nextlevel. for data centre IT infrastructure Efficiency-boosting solutions nextlevel for data centre 2 Rittal IT infrastructure The whole is more than the sum of its parts. The same is true of Rittal The System. With this in mind,

More information

Powerware Enclosure Solutions Product Focus

Powerware Enclosure Solutions Product Focus Powerware Enclosure Solutions Product Focus Powerware Enclosures IT availability and reliability are critical corporate issues in today s demanding, mission-critical environments. For this reason, it is

More information

or

or Infinite possibilities for your data center The F-Series TeraFrame T M Cabinet System The F-Series TeraFrame Cabinet System from Chatsworth Products, Inc. (CPI) provides configurable thermal management

More information

Hassle-free equipment installation

Hassle-free equipment installation 12U 36in Knock-Down Server Rack Cabinet with Casters StarTech ID: RK1236BKF This server rack provides 12U of storage space in a sleek secure cabinet for storing EIA-310 compliant 19 rackmount devices such

More information

Standard Product. Catalog Number. Width. Depth. mm 18 = = = = = = = = 400

Standard Product. Catalog Number. Width. Depth. mm 18 = = = = = = = = 400 Spec-01195 PROLINE G2 External Components Bases Gland Plate Gland plates are used with a plinth base to provide cable management solutions while maintaining a NEMA 12 rating. PROLINE G2 s unique Duro-Stand

More information

Hassle-free equipment installation

Hassle-free equipment installation 22U 36in Knock-Down Server Rack Cabinet with Casters StarTech ID: RK2236BKF This server rack provides 22U of storage space in a sleek secure cabinet for storing EIA-310 compliant 19 rackmount devices such

More information

DATACOM CABINETS SOLUTION GUIDE

DATACOM CABINETS SOLUTION GUIDE DATACOM CABINETS SOLUTION GUIDE designed to be better. LEGRAND S CABINET OFFERING Legrand cabinets are designed with cable management, airflow management and effortless installation to meet all network

More information

VERAK IP. 19 Stand Alone Cabinet with IP65 Rating.

VERAK IP. 19 Stand Alone Cabinet with IP65 Rating. 19 Stand Alone Cabinet with IP65 Rating www.apw.eu.com Overview Material specification Frame: Steel 2.0 mm Panel mounting angles and reducing channels: Steel 2.0 mm Panel mount supports: Steel 1.5 mm Side

More information

RittalXpress TS IT Enclosure Assemble-to-Order Program

RittalXpress TS IT Enclosure Assemble-to-Order Program RittalXpress TS IT Enclosure Assemble-to-Order Program DESIGN YOUR DATA CENTER BY THE NUMBERS. Count down to success: 4, 3, 2, 1... Complete four easy steps, your order can be shipped in three days and

More information

Accessories for control enclosures. BERNSTEIN attachment solutions. Double coupling head (console version with suspension system attachment)

Accessories for control enclosures. BERNSTEIN attachment solutions. Double coupling head (console version with suspension system attachment) 25 Accessories for control enclosures BERNSTEIN attachment Single coupling head (suspended console version) Double coupling head (console version with suspension system attachment) 322.5 231 232 140 The

More information

DIGITAL Server Rackmount Installation Guide

DIGITAL Server Rackmount Installation Guide DIGITAL Server Rackmount Installation Guide Part Number: ER-PCSRA-IA. E01 Digital Equipment Corporation December 1997 The information in this document is subject to change without notice and should not

More information

PI Server - 19 enclosures

PI Server - 19 enclosures PI Server - 19 The PI server enclosure range has been designed to complement our original PI Data enclosure and to accommodate the requirement of a cost effective server cabinet solution. This product

More information

W DATA SHEET: FREE-STANDING DATA ENCLOSURES DS

W DATA SHEET: FREE-STANDING DATA ENCLOSURES DS W DATA SHEET: FREE-STANDING DATA ENCLOSURES DS w TECHNICAL DATA Welded powder-coated sheet steel skeleton Heights: 15, 18, 22, 27, 32, 37, 42, 45 and 47 U Widths: 600 and 800 mm Depths: 400, 600, 800,

More information

Floor Standing Rack Cabinet

Floor Standing Rack Cabinet Floor Standing Rack Cabinet FEATURES: rear door with bolt lock front door panel with vented holes Reliable structure, static loading capacity: 600-00KG (Optional castors and plinth) Adjustable feet and

More information

OZLINX Solutions Australia Pty Ltd 21 Ayton Street, Sunshine North, Melbourne VIC3020 Australia Ph: Fax:

OZLINX Solutions Australia Pty Ltd 21 Ayton Street, Sunshine North, Melbourne VIC3020 Australia Ph: Fax: OZLINX Solutions Australia Pty Ltd 21 Ayton Street, Sunshine North, Melbourne VIC3020 Australia Ph: +61 3 93102440 Fax: +61 3 93102441 www.ozlinx.com OZLINX Cabinets OZLINX Cabinets OZLINX cabinets combine

More information

S-SERIES 2 Superior Rack Solution for Data Center & Network Closets

S-SERIES 2 Superior Rack Solution for Data Center & Network Closets S-SERIES Superior Rack Solution for Data Center & Network Closets S-SERIES II RACKS AND CONTAINMENT Vertiv S-Series Rack The S-Series Rack is an innovative enclosure system that integrates your computing

More information

Shelves, Keyboard Trays and Gland Plates Folding Shelves

Shelves, Keyboard Trays and Gland Plates Folding Shelves 763.422.2600 SPEC-00035 Q763.422.2211 ACCESSORIES SHELVES, KEYBOARD TRAYS AND GLAND PLATES FOLDING SHELVES Shelves, Keyboard Trays and Gland Plates Folding Shelves STAINLESS STEEL FOLDING SHELF Size AxB

More information

Specification Sheet: HT SERIES

Specification Sheet: HT SERIES Specification Sheet: HT SERIES HT Series: High Specification 19 Enclosures Hi-tech Series of 19 enclosures, supplied in self assembly (flat pack) format for ease of transportation and storage. Manufactured

More information

Rack 111 Catalog. Designed and Built to Exceed Your Needs.

Rack 111 Catalog. Designed and Built to Exceed Your Needs. Designed and Built to Exceed Your Needs. The Open Frame Server Rack is designed to provide users with a customizable solution engineered to meet a diverse set of rack mounting needs. This EIA server rack

More information

V800 Cabinet Solution

V800 Cabinet Solution WWW.SIEMON.COM V800 Cabinet Solution 8 V800 Cabinet Lightweight Stability Design provides an extremely stable, high-capacity cabinet without excessive weight Integrated Side Panel Grounding Spring loaded

More information

Vertiv Knürr MIR2 One system with Infinite Possibilities

Vertiv Knürr MIR2 One system with Infinite Possibilities VERTIV KNÜRR MIR2 4 Vertiv Knürr MIR2 One system with Infinite Possibilities Vertiv Knürr MIR, the classic amongst innovative racks, is demonstrated by the long-standing and continuous satisfaction of

More information

19" Wall Mounting Type QUICKBOX

19 Wall Mounting Type QUICKBOX ABINETS 19 - FREE Rack STANDING Cabinets - Wall TYPE Mounting 19 ESTAP DATA RACK 10" SOHOLINE 10 SOHOline cabinets provides an economical solution for wall mount mini-cabinets. The SOHOline features a

More information

Console systems 1.4. Features. TopConsole system TP. One-piece consoles AP. Universal consoles AP. Console systems

Console systems 1.4. Features. TopConsole system TP. One-piece consoles AP. Universal consoles AP. Console systems Console systems Features he performance capability of a machine or plant is decided at the console and operating unit. Rittal have set new standards in ergonomics, visual appearance and functionality for

More information

QuickSpecs. HPE G2 Enterprise Series Racks. Overview

QuickSpecs. HPE G2 Enterprise Series Racks. Overview Overview are designed for high density IT configurations deployed in a diverse set of environments from the data closet to the data center. Following EIA-310 specifications for 19-inch racks, G2 Enterprise

More information

Cabinet. DT-NCW NETWORK CABINET WALL MOUNT 9U - 60(W)x45(D)x46(H) 71,50 +VAT

Cabinet. DT-NCW NETWORK CABINET WALL MOUNT 9U - 60(W)x45(D)x46(H) 71,50 +VAT Cabinet DT-NCW-2-6409 NETWORK CABINET WALL MOUNT 9U - 60(W)x45(D)x46(H) 71,50 +VAT SPCC cold rolled steel One section wall mount rack Fan, shelf for optional DT-NCW-2-6412 NETWORK CABINET 12U - 60(W)x45(D)x59(H)

More information

EF-Series EuroFrame Gen 2 Cabinet System

EF-Series EuroFrame Gen 2 Cabinet System Protecting your technology investment. EF-Series EuroFrame Gen 2 Cabinet System The new generation of EF-Series EuroFrame Cabinet is a reliable and economical cabinet solution that supports rack-mount

More information

Elabo TaMo. Mobile carrier system for industrial use

Elabo TaMo. Mobile carrier system for industrial use Elabo TaMo Mobile carrier system for industrial use Elabo TaMo Modular carrier system M-Frame TaMo is conceived modularly. The M-frame basic carrier consists of the pivoting casters, the bottom plate which

More information

IBM. Rack Installation Instructions

IBM. Rack Installation Instructions IBM Rack Installation Instructions Review the documentation that comes with your rack cabinet for safety and cabling information. When installing your server in a rack cabinet, consider the following:

More information

707 Patching Frames. 505 Frames. 303 Frames. 404 & 202 Wallboxes. 505 Cabinets. 303 Cabinets. Cold Aisle Containment. 505 Server Cabinets

707 Patching Frames. 505 Frames. 303 Frames. 404 & 202 Wallboxes. 505 Cabinets. 303 Cabinets. Cold Aisle Containment. 505 Server Cabinets 303 Frames 505 Frames 707 Patching Frames 303 Cabinets 505 Cabinets 404 & 202 Wallboxes Standard Aisle Configuration 30 oc 40oc 30 oc 22 oc 22 oc 17 oc Cold Aisle 25 oc Hot Aisle 17 oc Cold Aisle Cold

More information

Rack Installation Instructions

Rack Installation Instructions Rack Installation Instructions Review the documentation that comes with your rack cabinet for safety and cabling information. When installing your server in a rack cabinet, consider the following: v Two

More information

Probably the fastest enclosure in the world

Probably the fastest enclosure in the world 95 9 enclosure system Probably the fastest enclosure in the world Sample configuration tools required no no tools required Vitaro can be assembled within less than 60 seconds. 00:00 00:0 00:08 00: 00:5

More information

UltraRack. Advanced Data Centre Enclosures SR SERIES

UltraRack. Advanced Data Centre Enclosures SR SERIES UltraRack Advanced Data Centre Enclosures SR SERIES Designed for scaleable growth The SR Series UltraRack SR Series - Universal rack enclosure solutions for advanced storage, cooling, power distribution,

More information

TopConsole system TP. Combination options 1-part 2-part 3-part. System accessories Page 537 Monitors, keyboards From page 796 Climate control Page 389

TopConsole system TP. Combination options 1-part 2-part 3-part. System accessories Page 537 Monitors, keyboards From page 796 Climate control Page 389 opconsole system P System accessories Page 537 Monitors, keyboards From page 796 Climate control Page 389 Enclosure: Sheet steel 1.5 mm Door and console cover: Sheet steel, 2.0 mm, all-round foamed-in

More information

FI Server Range. 600mm Wide 800mm Wide Door Options

FI Server Range. 600mm Wide 800mm Wide Door Options TM FI Server Range 600mm Wide 800mm Wide Door Options The Fi server cabinet range was designed by our in-house team of engineers to meet the needs of today s high density data centre installations. The

More information

Rackmount Shelves, Wallmount Shelves, Keyboard/Mouse Trays

Rackmount Shelves, Wallmount Shelves, Keyboard/Mouse Trays Rackmount Shelves Wallmount Shelves Keyboard/Mouse Trays Product Data Sheet Rackmount Shelves, Wallmount Shelves, Keyboard/Mouse Trays Overview Black Box offers a variety of 1U, 2U, and 3U high shelves

More information

Data sheet. Server Rack ( heavy duty rack cabinet ) W:600 = D:1000

Data sheet. Server Rack ( heavy duty rack cabinet ) W:600 = D:1000 Data sheet Server Rack ( heavy duty rack cabinet ) General description This is a unique server enclosure which is designed for housing heavy server & Networking systems, Server Rack cabinets are compatible

More information

Ideal protection for your electrics: häwa cable ducts

Ideal protection for your electrics: häwa cable ducts Ideal protection for your electrics: häwa cable ducts Well Conceived The häwa group has established itself as an innovative and highly competent supplier to machinery and facility equipment companies in

More information

DK-PS Rack. New generation DK-PS Rack for room climate control

DK-PS Rack. New generation DK-PS Rack for room climate control DK-PS Rack DK-PS Rack New generation DK-PS Rack for room climate control Rack as the support for IT equipment is the main component of the data center; Reliable,eficiency and flexible is the main requirement

More information

EMEA. Product Catalog. RackLine. AT&T Rack & Enclosure LAN Cabling Products. AT&T Cabling Systems

EMEA. Product Catalog. RackLine. AT&T Rack & Enclosure LAN Cabling Products. AT&T Cabling Systems EMEA Product Catalog 2014 AT&T Rack & Enclosure LAN Cabling Products AT&T Cabling Systems provide complete enterprise solutions and state-of-the-art LAN cabling components for all needs. AT&T Cabling Systems

More information

APC Open Frame Rack Networking Solutions

APC Open Frame Rack Networking Solutions APC Open Frame Rack Networking Solutions NetShelter 2- and 4 Post Open Frame Racks The NetShelter 2 and 4 Post Open Frame Racks offer a quality solution for the economical installation of rackmountable

More information

RACKS AND CABLE MANAGEMENT

RACKS AND CABLE MANAGEMENT F/ F/ Assemblies, 11.0 W W W. S I E M O N. C O M SECTION CONTENTS RS3 Rack System........ 11.2 11.3 RS3 Series Horizontal Managers........... 11.3 F/ RS Rack System............................. 11.4 Extended

More information

Rack Installation Instructions

Rack Installation Instructions Rack Installation Instructions For System Storage EXP2512 and EXP2524 Express Storage Enclosures Use the instructions in this document to install an IBM System Storage EXP2512 Express Storage Enclosure

More information

Knürr Elicon Ergonomic. Modular. Future-proof. Control Room Infrastructure

Knürr Elicon Ergonomic. Modular. Future-proof. Control Room Infrastructure Knürr Elicon Ergonomic. Modular. Future-proof Control Room Infrastructure Knürr Elicon Knürr Elicon VC and VC-E Series 4 Modular Workstation Systems Knürr Elicon Classic 14 Knürr Elicon Accessories 22

More information

1993 Specifications CSJ SPECIAL SPECIFICATION ITEM Transportation Management Console

1993 Specifications CSJ SPECIAL SPECIFICATION ITEM Transportation Management Console 1993 Specifications CSJ 0598-01-057 1.0 Description SPECIAL SPECIFICATION ITEM 6398 Transportation Management Console This Item shall govern for the furnishing and installation of Transportation Management

More information

Networking Cabinets and Enclosures

Networking Cabinets and Enclosures Networking Cabinets and Enclosures Excel is a world-class premium performing end-to-end infrastructure solution - designed, manufactured, supported and delivered - without compromise. Networking Cabinets

More information

PROLINE ExtERNaL COmPONENts 0-mm solid BasE Catalog Number Fits Frame B x C W (mm) W (in.) D (mm) D (in.) PB045 PB046 PB064 PB064HF2 PB065HF2 PB066

PROLINE ExtERNaL COmPONENts 0-mm solid BasE Catalog Number Fits Frame B x C W (mm) W (in.) D (mm) D (in.) PB045 PB046 PB064 PB064HF2 PB065HF2 PB066 Spec-00429 PROLINE External Components PROLINE Tops and Bases 0-mm Solid Base The 0-mm bases are finished with RAL 7035 textured light-gray polyester powder paint (except stainless steel). EMC bases are

More information

Knürr Elicon Ergonomic, modular, future-proof Cost-optimized installation options. Technical Furniture

Knürr Elicon Ergonomic, modular, future-proof Cost-optimized installation options. Technical Furniture Knürr Elicon Ergonomic, modular, future-proof Cost-optimized installation options Technical Furniture Knürr Elicon Applications Capabilities 2 Knürr Elicon Strong points 4 Knürr Elicon Modules Side Panel

More information

Make IT easy: The new TS IT rack

Make IT easy: The new TS IT rack Make IT easy: The new TS IT rack The new TS IT rack. A new global standard for network and server equipment. At CeBIT 202, Rittal unveiled a newly developed rack system which is set to redefine the global

More information

PROLINE ExtERNal ComPONENts. PROLINE tops and Bases

PROLINE ExtERNal ComPONENts. PROLINE tops and Bases Spec-00428 E763.422.2211 763.422.2600 PROLINE ExtERNal ComPONENts PROLINE Tops and Bases PROLINE ExtERNal ComPONENts PROLINE tops and Bases Solid tops Solid Tops are used to close the top opening on an

More information

InForm Superstructures

InForm Superstructures Advantages InForm racks are fitted between the vertical profiles and thus ensure a generous amount of open working table surface. Devices are installed directly in the 3HU and 6HU racks, additional devices

More information

Pixus Technologies Catalog

Pixus Technologies Catalog The Power of Embedded Ingenuity Pixus Technologies Catalog Kaparel, Ripac, & Vario Brand Products www.pixustechnologies.com sales@pixustechnologies.com S: 96.524.8242 CAN: 59.885.5775 Product Diversity

More information

SPECTRUM-2 CONSOLES. TEL: WEB: winsted.com

SPECTRUM-2 CONSOLES. TEL: WEB: winsted.com SPECTRUM-2 CONSOLES TEL: 800.447.2257 WEB: winsted.com EMAIL: info@winsted.com PRODUCT FEATURES AND HIGHLIGHTS Laminate with Safeguard Work Surface Spectrum 2 comes standard with our durable laminated

More information

QuickSpecs. HPE G2 Advanced Series Racks. Overview

QuickSpecs. HPE G2 Advanced Series Racks. Overview HPE G2 Advanced Series Racks Overview HPE G2 Advanced Series Racks HPE G2 Advanced Series Racks are designed for low-to-medium density IT configurations deployed in a diverse set of environments from the

More information

KM6-II Subracks. APW Electronic Solutions. 152 APW Electronic Solutions Toll Free (800) Fax: (858)

KM6-II Subracks. APW Electronic Solutions. 152 APW Electronic Solutions Toll Free (800) Fax: (858) KM6-II Subracks Fully compatible with DIN41494 part 5 and IEC60297-3. KM6-II Standard is available in kit form, offering quick and simple assembly. KM6-II Universal is a highly versatile subrack system,

More information

Quick Start. This document describes how to install the Juniper Networks PTX5000 Packet Transport

Quick Start. This document describes how to install the Juniper Networks PTX5000 Packet Transport PTX5000 Packet Transport Router Quick Start September 2017 Part Number: 530-066788 Revision 01 This document describes how to install the Juniper Networks PTX5000 Packet Transport Router. Contents Quick

More information

InstaRack Server. Specifications & Accessories

InstaRack Server. Specifications & Accessories InstaRack Server Specifications & Accessories Emerson Network Power, a division of Emerson, is a global company that provides a unique combination of industry expertise, technology, and resources to make

More information

Pixus Technologies Catalog

Pixus Technologies Catalog The Power of Embedded Ingenuity Pixus Technologies Catalog Kaparel, Ripac, & Vario Brand Products www.pixustechnologies.com sales@pixustechnologies.com US: 96.524.8242 CAN: 59.885.5775 Product Diversity

More information

PROLINE ExtERNal ComPONENts. PROLINE tops and Bases

PROLINE ExtERNal ComPONENts. PROLINE tops and Bases Spec-00429 H763.422.2211 763.422.2600 PROLINE ExtERNal ComPONENts PROLINE Tops and Bases PROLINE ExtERNal ComPONENts PROLINE tops and Bases 0-mm Solid Base The 0-mm bases are finished with RAL 7035 textured

More information

Rack Installation Instructions

Rack Installation Instructions Rack Installation Instructions Review the documentation that comes with your rack cabinet for safety and cabling information. Before installing your server in a rack cabinet, review the following guidelines:

More information

Rack Mount Interconnect Center (RIC3)

Rack Mount Interconnect Center (RIC3) Rack Mount Interconnect Center (RIC) The RIC provides the best overall value for exceptional fiber management. The RIC enclosure offers superior fiber density (up to 88 fibers in just U) without sacrificing

More information

Free-Standing Type 12 Enclosures

Free-Standing Type 12 Enclosures Type 12 Enclosures Application Designed to protect electrical and electronic controls, components, and instruments in typical industrial environments. The UL Type 12 rating protects enclosed equipment

More information

ALPHA SIMBOX Small Distribution Boards

ALPHA SIMBOX Small Distribution Boards ALPHA SIMBOX Small Distribution Boards /2 Introduction /3 Introduction /4 Flush-mounting and hollow-wall distribution boards /5 Surface-mounting and hood-type distribution boards /6 Accessories /7 Dimensional

More information

INDUSTRIAL WORKSTATIONS. The new dimension at the interface between man and machine for enhanced workspace safety ergonomics

INDUSTRIAL WORKSTATIONS. The new dimension at the interface between man and machine for enhanced workspace safety ergonomics INDUSTRIAL WORKSTATIONS The new dimension at the interface between man and machine for enhanced workspace safety ergonomics Diversity is the strength of. More workspace than with a PC enclosure. More compact

More information

Ripac VME/VME64x Systems. Applications. Design Features

Ripac VME/VME64x Systems. Applications. Design Features Overview Of Systems For VMEbus Ripac VME/VME64x Slim-Box Ripac VME/VME64x Systems Ripac VME/VME64x Systems 1, 2, 3, 4U/2, 4, 6, 8 slot in AC input Order No. see pages 110-112 For backplanes see page 60

More information

PRELIMINARY. CR Series. Ceiling Rack Systems with AmbiTILT Equipment Loading

PRELIMINARY. CR Series. Ceiling Rack Systems with AmbiTILT Equipment Loading 1/6 CR Series Ceiling Rack Systems with AmbiTILT Equipment Loading General Description AtlasIED, the manufacturing leader of ceiling mounted loudspeakers introduces the new CR Series ceiling-mounted equipment

More information

Audio Visual & Telecoms Rotation Rack. AVATR RACK

Audio Visual & Telecoms Rotation Rack.  AVATR RACK www.avatrav.com AVATR RACK Audio Visual & Telecoms Rotation Rack The AVATR Racking System from Midas Enterprise Group provides the perfect solution for todays audio visual & home entertainment installations.

More information

System Storage EXP3000 Rack Installation Instructions

System Storage EXP3000 Rack Installation Instructions System Storage EXP3000 Rack Installation Instructions Review the documentation that comes with your rack cabinet for safety and cabling information. When you install the IBM System Storage EXP3000 in a

More information

Netfinity White Paper Netfinity Technology Center

Netfinity White Paper Netfinity Technology Center Netfinity White Paper Netfinity Technology Center Rack Storage Expansion Enclosure Planning Guide Abstract This paper is designed for use by Pre-Sales technical marketing representatives. This includes

More information

SECTION 5 -- EQUIPMENT LAYOUT & EQUIPMENT ENVIRONMENTS

SECTION 5 -- EQUIPMENT LAYOUT & EQUIPMENT ENVIRONMENTS SECTION 5 -- EQUIPMENT LAYOUT & EQUIPMENT ENVIRONMENTS CONTENTS PAGE 1. GENERAL... 5-1 1.1. Introduction... 5-1 1.2. Equipment Layout Requirements... 5-1 2. EQUIPMENT FRAMES... 5-2 2.1. Introduction...

More information

4-Post and Universal Telco Frame (UTF) Rack Mount Kit Installation Instructions

4-Post and Universal Telco Frame (UTF) Rack Mount Kit Installation Instructions 4-Post and Universal Telco Frame (UTF) Rack Mount Kit Installation Instructions Review the documentation that comes with your rack cabinet for safety and cabling information. Before installing your server

More information

New products spring 2018

New products spring 2018 New products spring 2018 MODULAR SOLUTIONS CASY SERIES DESKTOP CHASSIS Front module mounting Large access holes on rear Structured black powder coating (RAL9004) Aluminum extruded frame with plastic sides

More information

RUGGED MILITARY GRADE

RUGGED MILITARY GRADE R4U-20A RUGGED MILITARY GRADE COTS Plus 4U ENCLOSURE Optimized for High Shock / Vibration Environments C6CHASSIS SYSTEMS ENGINEERED TO PERFORM The R4U-20A is designed to survive! Aircraft grade aluminum

More information

ABINETS - FREE STANDING TYPE 19 ESTAP DATA RACK REE STANDING TYPE FIBER TERMINATION BOXES

ABINETS - FREE STANDING TYPE 19 ESTAP DATA RACK REE STANDING TYPE FIBER TERMINATION BOXES ABINETS - FREE STANDING TYPE 19 ESTAP DATA RACK WHO WE ARE ESTAP ELECTRONIC PACKAGING company has been a major force in the Turkey electronics enclosures industry since 1989. The company offers a comprehensive

More information

The Most Advanced Racking Solutions Available!

The Most Advanced Racking Solutions Available! The Most Advanced Racking Solutions Available! 1-877-427-5722 www.sharkrack.com info@sharkrack.com Your local authorized SharkRack reseller: Copyright SharkRack, Inc. Prices and specifications are subject

More information

Flex-Block base/plinth system. Packs of

Flex-Block base/plinth system. Packs of Base Flex-Block base/plinth system Baying clip for baying the Flex-Block corner pieces Simply insert the clip from behind into the recesses provided (no need for tools). Fibreglass-reinforced polyamide

More information

1/2 Introduction. SIMBOX LC 1/7 Introduction 1/8 Flush-mounting and surfacemounting. 1/9 Dimensional drawings

1/2 Introduction. SIMBOX LC 1/7 Introduction 1/8 Flush-mounting and surfacemounting. 1/9 Dimensional drawings Siemens AG 200 ALPHA SIMBOX Small Distribution Boards /2 Introduction /2 Introduction /3 Flush-mounting and hollow-wall distribution boards /4 Hood-type distribution boards /5 Accessories /6 Dimensional

More information

F-SERIES Innovative Rack Solution

F-SERIES Innovative Rack Solution F-SERIES Innovative Rack Solution F-SERIES RACK Your mission-critical networks are carrying an ever increasing amount of voice, data and video. Looming on the horizon is a critical mass of VoIP, high speed

More information

CNC Tool Storage Solutions

CNC Tool Storage Solutions CNC Tool Storage Solutions Thanks to the flexibility of the CNC line, your tools will be protected during regular handling, transportation and storage. The Rousseau CNC tool rack distinguishes itself in

More information

Take a really close look Quality and compatibility play a superior role in integrated systems and infrastructures we can stand up to closer scrutiny

Take a really close look Quality and compatibility play a superior role in integrated systems and infrastructures we can stand up to closer scrutiny Take a really close look Quality and compatibility play a superior role in integrated systems and infrastructures we can stand up to closer scrutiny DIGITUS Professional defines a clear benchmark for the

More information

Server Rack Cabinet Compatibility Guide

Server Rack Cabinet Compatibility Guide Server Rack Cabinet Compatibility Guide Revision 2.4 September 2005 A Guide to the Selection and Evaluation of Server Rack Cabinets for Compatibility and Use with Intel Server Chassis Disclaimer THE INFORMATION

More information

DIGITUS Server Cabinet Unique Series

DIGITUS Server Cabinet Unique Series 15 Years Product Warranty kg loading capacity Modular aluminum frame construction large range of equipment available Overview DIGITUS Server Cabinet Unique Series 600, 800 mm width mm depth Features Safety

More information

Fibre Enlosures and Splicing

Fibre Enlosures and Splicing Fibre Enlosures and Splicing Siemon s fibre enclosures provide feature-rich and easily implemented options for managing critical fibre connectivity. With versions supporting up to 88 fibre ports, Siemon

More information

Installation and Maintenance

Installation and Maintenance CHAPTER 4 Installation and Maintenance Revised: April 19, 2010, Introduction This chapter explains how to install a SCE 1000 platform in a rack or in a general tabletop or workbench installation. Additionally,

More information

Switch cabinet housings. Distribution housings. Appropriate housings for each application. Our experience. Your safety.

Switch cabinet housings. Distribution housings. Appropriate housings for each application. Our experience. Your safety. Switch cabinet housings Distribution housings Appropriate housings for each application Our experience. Your safety. Overview of the housing ranges Mounting rail bus system In-Rail Bus...6 Switch cabinet

More information

V-Built Custom Preconfigured Solutions

V-Built Custom Preconfigured Solutions WWW.SIEMON.COM V-Built Custom Preconfigured Solutions 8 One Part Number, One Price Ready to Roll Available with any Siemon cabinet, rack or enclosure, Siemon s V-Built Custom Preconfigured Solutions are

More information

CNC Tool Storage Solutions

CNC Tool Storage Solutions CNC Tool Storage Solutions Thanks to the flexibility of the CNC line, your tools will be protected during regular handling, transportation and storage. The Rousseau CNC tool rack distinguishes itself in

More information

ALPHA Small Distribution Boards SIMBOX 63/SIMBOX WP

ALPHA Small Distribution Boards SIMBOX 63/SIMBOX WP ALPHA Small Distribution Boards SIMBOX 63/SIMBOX WP SIMBOX 63 /4 Introduction /5 Flush mounting distribution boards /6 Hollow-wall distribution boards /7 Surface mounting distribution boards /7 Hood-type

More information

QuickSpecs. HPE G2 Enterprise Series Racks. Overview

QuickSpecs. HPE G2 Enterprise Series Racks. Overview Overview are designed for high density IT configurations deployed in a diverse set of environments from the data closet to the data center. Following EIA-310 specifications for 19-inch racks, G2 Enterprise

More information

S-Series Superior Rack Solution for Data Centre & Network Closets

S-Series Superior Rack Solution for Data Centre & Network Closets S-Series Superior Rack Solution for Data Centre & Network Closets s-series rack Your mission-critical networks are carrying an ever increasing amount of voice, data and video. Your business relies heavily