Optical multi-speed splitting

Size: px
Start display at page:

Download "Optical multi-speed splitting"

Transcription

1 Optical multi-speed splitting For Xena 00 G and 40 G test modules Xena 00GE and 40GE test modules can support 00 Gbps, 50 Gbps, 40 Gbps, 25 Gbps and 0 Gbps port speeds depending on test module, transceiver and in some cases splitter cables. This Application Note describes what can be achieved with the modules and describes various topics related to this context. Finally, it includes an example on how to configure a 00 G test module to speeds supported by the module.

2 Contents Application Note... 3 Transmission of 40 Gbps and 00 Gbps signals... 4 Naming of 00 G to 0 G Interface Options... 5 What is the difference between 00GBASE-LR4 and 00GBASE-CWDM4?... 5 Direct Attached Cables (DACs) and Active Optical Cables (AOC)... 5 Optical Connectors... 6 Break Out Cables and Splitter Cables... 7 Splitter Cassette P/N SR0-2xSR Multiple Port Speeds in Xena 00 G and 40 G test modules... 9 What goes where?... 4 Configuring Xena 00 G and 40 G test modules... 5 SR0 <-> 2 x LC MMF Splitter Cable... 9 SR4 <-> 4 x LC and ism4 <-> 4 x LC splitter cables

3 APPLICATION NOTE Xena Networks 00GE and 40GE test modules can support 00 Gbps, 50 Gbps, 40 Gbps, 25 Gbps and 0 Gbps port speeds depending on test module, transceiver and in some cases splitter cables. This Application Note describes what can be achieved with the test modules and explains various related topics like: The use of parallel paths for transmission of high speed signals Naming conventions for 00 G to 0 G Interface options The difference between 00GBASE-LR4 and 00GBASE-CWDM4 Optical connectors used for high speed transmission You will find information on transceivers, cables and other items available from Xena Networks. You can also see how these that can be used with the Xena 00GE and 40GE test modules in the What Goes Where section. Finally, the Application Note includes an example on how to configure a 00 G test module to the speeds supported by the module. 3

4 TRANSMISSION OF 40 GBPS AND 00 GBPS SIGNALS When 40 Gbps communication signals are transmitted between communication devices, they are sent as 4 parallel 0 Gbps streams (lanes). For 00 Gbps signals there are two options: The signals are either sent as 0 parallel 0 Gbps lanes or 4 parallel 25 Gbps lanes. For the physical media between communications devices there are two options: Very short ranges (up to 7 meters): Electrical cables are normally used as they are cost effective. Longer distances: Optical cables are used. For distances up to 00 meters multimode cables can be used; for longer distances the more expensive single mode cables are needed. Optical 40 Gbps and 00 Gbps can be sent in two ways:. As 4 (or 0) physical signals. This means that 4 (or 0) optical fibers are needed between the communication devices (multi-fiber connections). Figure : Several fibers between devices 2. With 4 (or 0) optical wave lengths using Wavelength Division Multiplexing (WDM) techniques. This means that the signals are sent as several different wavelengths (or colors) in parallel over a single optical fiber. This is used for longer distances as only one optical cable is required. Figure 2: A single fiber between devices several wavelengths are used 40 Gbps and 00 Gbps Multimode fiber optic systems are normally implemented as multi-fiber connections, while Single Mode fiber optic systems normally use WDM techniques. However Single Mode fiber optic can also use multi-fiber connections, which is also known as Parallel Single Mode (PSM) or PSM4 when 4 fibers are used in parallel. Electrical 40 Gbps and 00 Gbps are always sent as 4 (or 0) physical electrical signals, which means that 4 (or 0) electrical cables are needed between the devices. 4

5 NAMING OF 00 G TO 0 G INTERFACE OPTIONS 00 G to 0 G Interface options are normally named xxxgbaseyy#, where xxx indicates the speed (xxx=00 means 00 Gbps, XXX= 40 means 40 Gbps and so on yy typically indicates reach and cable type: o yy=cr means very short reach on an electrical Copper cable o yy=sr means short reach on a multimode optical fiber o yy=lr means long reach on a single mode optical fiber o yy=er means extended reach on a single mode optical fiber # shows number of lanes i.e. #=4 for 4 lanes and #=0 for 0 lanes WHAT IS THE DIFFERENCE BETWEEN 00GBASE-LR4 AND 00GBASE-CWDM4? There are two versions of 4 lane 00 Gbps optical WDM systems running on a single mode fiber: 00GBASE- LR4/ER4 and 00GBASE-CWDM4 (CWDM = Coarse Wavelength Division Multiplex). 00GBASE-LR4 and 00GBASE-ER4 are both defined by IEEE in IEEE 802.3ba; 00GBASE-CWDM4 is defined by CWDM4 MSA group as a lower cost alternative for distances up to 2 km in data center applications. Both systems use 4 different wavelengths for the 4 lanes: 00GBASE-LR4/ER4 uses nm, nm, nm and nm 00GBASE-CWDM4 uses 27 nm, 29 nm, 3 nm and 33 nm DIRECT ATTACHED CABLES (DACS) AND ACTIVE OPTICAL CABLES (AOC) 40 Gbps and 00 Gbps communication devices are normally equipped with cages where transceivers can be installed. In some cases, the cables between devices are directly connected to the transceivers, which are known as Direct Attached Cables (DACs). Connections with electrical cables are normally made with DACs. DACs with optical cables and transceivers are also known as Active Optical Cables (AOC). Description Type Length See Fig. FCBN425QBC05 (AOC) Finisar 00G QSFP28 00GBASE-SR4 AOC 5 m 4 200LF (DAC) FCI Direct Attached Cable, 4 x 25Gbps qualified, AWG30 DAC m LF (DAC) FCI Direct Attached Cable, 4 x 25Gbps qualified, AWG30 DAC 3 m LF (DAC) FCI Direct Attached Cable, 4 x 25Gbps qualified, AWG26 DAC m 3 Table : 00 Gbps QSFP28 AOC and DACs available from Xena 5

6 Figure 3: 00 Gbps DAC with two electrical QSFP28 transceivers Figure 4: 00 Gbps AOC with two optical QSFP28 transceivers OPTICAL CONNECTORS Optical transceivers are equipped with connectors unless they are a part of an Active Optical Cable. Two types are normally used:. Multi-fiber connections: Multi-fiber Push-On (MPO) connectors are used. They can connect up to 2 (MPO2) or 24 (MPO24) optical fibers. For 4 lane systems 8 fibers are required (4 for the optical transmitters and 4 fibers for the optical receivers). These systems will use 8 of the 2 fiber connections in MPO2 connectors. 0 lane systems will use 20 of the 24 connections in MPO24 connectors. Multi-fiber Termination Push-on (MTP) is a brand name for an improved connector developed by US Connect; MTP connects to MPO. Figure 5: 2 fiber ends in an MPO2 connector; 24 fiber ends in an MPO24 connector 2. Single fiber connections: Transceivers and fiber cables are normally equipped with LC connectors; two fiber cables are required, one transmit, one receive. Figure 6: LC connector 6

7 BREAK OUT CABLES AND SPLITTER CABLES For some applications like connecting servers to Topof-Rack (ToR) switches in data centers, it is relevant to use the 4 25 Gbps lanes in a multi-cable connection as 4 individual 25 Gbps data streams. Hereby you can connect a 00 Gbps port in the ToR with 4 data center servers equipped with 25 Gbps ports. This is done with a DAC or AOC break out cable connecting a QSFP28 00GbE port with four independent 25GE SFP28 ports. The DAC/AOC break out cable will have a QSFP28 transceiver connected in one end breaking out to four cables, each terminated with a SFP28 transceiver. Figure 7: 00 GE to 4*25 GE break-out cable DAC and AOC break out cables are available for electrical and optical interfaces, where 40 Gbps and 00 Gbps signals are sent as 4 (or 0) physical signals. For single fiber connections break out cables are not available; splitting a WDM signal into 4 lower rate signals would require a WDM multiplexer/demultiplexer. Figure 8: 00 Gigabit/s QSFP28 to 4 x 25 Gigabit/s SFP28 DAC electrical break-out cable Figure 9: 00 Gigabit/s QSFP28 to 4 x 25 Gigabit/s SFP28 break-out Active Optical Cable (AOC) In addition to DAC and AOC break out cables, passive optical breakout cables (or splitter cables) are available splitting a 4 (or 0) lane signal into 4 (or 0) separate signals. This means for example that 4 25 Gbps optical signals from a QSFP28 optical transceiver with MPO/MTP connector can be split into 4 individual cable pairs to be connected to SFP28 optical transceivers with LC connectors as shown in figure 0. 7

8 Figure 0: MTP to 4 dual LC passive optical splitter cable cable For 0 lane multi-fiber optical transceivers with MPO24 connectors optical splitter cables can split the signal into 2 cable pairs, providing access to all 24 fibers in the MPO24 connector. Description Cable Length See type Fig. SR4-4xLC Optical splitter cable, SR4 MTP(F) <-> 4 x LC MMF 5 m 0 ism4-4xlc Optical splitter cable, ism4 MTP(F) <-> 4 x LC SMF 5 m 0 SR4-LOOP Loopback fiber cable, SR4, MTP(F) MMF SR0-2xSR4 Cassette, SR0 MTP(F) <-> 2 x QSFP receptacle, including 3 mm MMF 3 SR0 cable SR0-2xLC Optical splitter cable, SR0 MTP(F) <-> 2 x LC (Molex MMF 5 m ) SR0-LOOP Loopback fiber cable, SR0, MTP(F), MMF SR4-Trunk MTP(female) to MTP(female) 50/25/OM3, 2 Fiber Dia. 3,0mm MMF 3 m 2 SR0-Trunk MTP(female) to MTP(female) 50/25/OM3, 24 Fiber Dia. 3,8mm MMF 3 m 2 Table 2: Cables and splitters available from Xena As you can see in table 2, splitter cables are equipped with MTP (MPO) connectors. They can split signals from optical (multi-fiber) transceivers that also are equipped with MTP (MPO) connectors; they can t split signals from optical (WDM) transceivers with LC connectors. Figure : Two SR4-LOOP Loopback fiber cables Figure 2: SR4-Trunk cable 8

9 SPLITTER CASSETTE P/N SR0-2XSR4 Figure 3: Splitter Cassette for 00GBASE-SR0 (MPO) <-> 2 x 40GBASE-SR4 MPO connectors (P/N SR0-2xSR4) SR0-2xSR4 is a device equipped with one MPO24 connector and two MPO2 connectors. The MPO24 connector must be connected to a 00GBASE-SR0 transceiver with MPO24 connector through a MTP/MPO24-to-MTP/MPO24 cable (e.g. the cable SR0-Trunk available from Xena). Inside the device the MPO24 connector is connected to two MPO2 connectors using 2 x 8 fibers. The MPO2 connectors will act as two 40GBASE-SR4 (QSFP+) transceivers. MULTIPLE PORT SPEEDS IN XENA 00 G AND 40 G TEST MODULES Xena Networks 00 G and 40 G test modules can support 00 Gbps, 50 Gbps, 40 Gbps, 25 Gbps and 0 Gbps port speeds depending on test module, transceiver module and in some cases splitter cables. Tables 3 and 4 give an overview of the speeds supported by each of the Xena 00 G and 40 G test modules. Product Number Port Speed Interface Form Factor No. of Ports Type of Interface MCFP00 3 speed MQSFP28CXP 3 speed Dual-media MCFP4QSFP28CXP 3 speed Triple-media MQSFP28SFP28 5 speed Dual-media 00G (or) 0G 00G (or) 00G (or) 0G 00G (or) 00G (or) 00G (or) 0G 00G (or) 50G (or) 25G (or) 0G (or) 25G (or) 0G Table 3: Xena 00G test modules CFP 2 8 QSFP28 QSFP28/QSFP+ CXP CXP CXP CFP4 QSFP28 QSFP28/QSFP+ CXP CXP CXP QSFP28 QSFP28 QSFP28/QSFP+ QSFP28 QSFP28/QSFP+ SFP28 SFP28/SFP GBASE-SR0/LR4 40GBASE-SR4/LR4 40GBASE-SR4 0GBASE-iSR 00GBASE-SR4/LR4/CWDM4 40GBASE-SR4/LR4 00GBASE-SR0 40GBASE-iSR4 0GBASE-iSR 00GBASE-SR4/LR4 00GBASE-SR4/LR4/CWDM4 40GBASE-SR4/LR4 00GBASE-SR0 40GBASE-SR4 0GBASE-iSR 00GBASE-SR4/LR4/CWDM4/CR4 50GBASE-SR2/LR2/CR2 40GBASE-SR4/LR4/CR4 25GBASE-SR/LR/CR 0GBASE-iSR 25GBASE-SR/LR/CR 0GBASE- SR/LR/CR 9

10 Product Number Port Speed M2QSFP+ 0G M2CFP40 0G Table 4: Xena 40G test modules Interface No. of Form Factor Ports QSFP+ 2 8 CFP 2 8 Type of Interface 40GBASE-SR4/LR4/DAC 0GBASE-iSR/iSM/DAC 40GBASE-LR4 40GBASE-SR4 0GBASE-iSR For isr the i represents interoperability between the transceiver and any 0GBASE-SR compliant modules. For ism, the i represents interoperability between the transceiver and any single mode (SM) 0GBASE-LR compliant modules up to 2 km link length. To change the port speed, the user must configure the port speed and in some cases change transceiver and cables. A summary of the port speeds supported by Xena 00 G and 40G test modules together with the transceiver type required to support a given speed is shown in tables 5 to 0. Cages Port Speeds / Cable Transceiver Type Interface Options Type x CFP x 00GBASE-LR4 SMF 00GBASE-LR4 x 40GBASE-LR4 SMF 40GBASE-LR4 x 00GBASE-SR0 MMF 00GBASE-SR0 2 x 40GBASE-SR4 MMF 00GBASE-SR0 and splitter 8 x 0GBASE-SR MMF 00GBASE-SR0 and splitter Table 5: Port speeds supported by Xena MCFP00 Cages Port Speeds / Cable Transceiver Type Interface Options Type x QSFP28/QSFP+ x 00GBASE-SR0 MMF 00GBASE-SR0 x CXP 2 x 40GBASE-iSR4 MMF 00GBASE-SR0 and splitter 8 x 0GBASE-iSR MMF 00GBASE-SR0 and splitter x 00GBASE-SR4 MMF 00GBASE-SR4 x 00GBASE-LR4 SMF 00GBASE-LR4 x 00GBASE-CWDM4 SMF 00GBASE-CWDM4 x 40GBASE-SR4 MMF 40GBASE-SR4 x 40GBASE-LR4 SMF 40GBASE-LR4 Table 6: Port speeds supported by Xena MQSFP28CXP 0

11 Cages Port Speeds/ Cable Transceiver Type Interface Options Type x CFP4 x 00GBASE-SR0 MMF 00GBASE-SR0 x QSFP28/QSFP+ x 40GBASE-iSR4 MMF 00GBASE-SR0 and splitter x CXP 8 x 0GBASE-iSR MMF 00GBASE-SR0 and splitter x 00GBASE-SR4 MMF 00GBASE-SR4 x 00GBASE-LR4 SMF 00GBASE-LR4 x 00GBASE-SR4 MMF 00GBASE-SR4 x 00GBASE-LR4 SMF 00GBASE-LR4 x 40GBASE-SR4 MMF 40GBASE-SR4 x 40GBASE-LR4 SMF 40GBASE-LR4 Table 7: Port speeds supported by Xena MCFP4QSFP28CXP Cages Port Speeds/ Cable Transceiver Type Interface Options Type x QSFP28/QSFP+ x 00GBASE-SR4 MMF 00GBASE-SR4 2 x SFP28/SFP+ x 00GBASE-LR4 SMF 00GBASE-LR4 x 00GBASE-CWDM4 SMF 00GBASE-CWDM4 x 00GBASE-CR4 Copper 00GBASE-CR4 (DAC) 2 x 50GBASE-SR2 MMF 00GBASE-SR4 and splitter 2 x 50GBASE-LR2 SMF 00GBASE-LR4 PSM4 and splitter 2 x 50GBASE-CR2 Copper 00GBASE-CR4 (DAC with break-out) 4 x 25GBASE-SR MMF 00GBASE-SR4 and splitter 4 x 25GBASE-LR SMF 00GBASE-LR4 PSM4 and splitter 4 x 25GBASE-CR Copper 00GBASE-CR4 (DAC with break-out) x 40GBASE-SR4 MMF 40GBASE-SR4 x 40GBASE-LR4 SMF 40GBASE-LR4 x 40GBASE-CR4 Copper 40GBASE-CR4 4 x 0GBASE-iSR MMF 40GBASE-SR4 and splitter 2 x 25GBASE-SR MMF 25GBASE-SR 2 x 25GBASE-LR SMF 25GBASE-LR 2 x 25GBASE-CR Copper 25GBASE-CR (DAC) 2 x 0GBASE-SR MMF 0GBASE-SR 2 x 0GBASE-LR SMF 0GBASE-LR 2 x 0GBASE-CR Copper 0GBASE-CR Table 8: Port speeds supported by Xena MQSFP28SFP28

12 Cages Port Speeds/ Interface Options Cable Type 2 x QSFP+ 2 x 40GBASE-LR4 SMF 40GBASE-LR4 2 x 40GBASE-SR4 MMF 40GBASE-SR4 8 x 0GBASE-iSR MMF 40GBASE-SR4 with splitter 8 x 0GBASE-iSM SMF 4x0GBASE-LR4 PSM4 with splitter Table 9: Port speeds supported by Xena M2QSFP+ Cages Port Speeds/ Cable Transceiver Type Interface Options Type x CFP x 40GBASE-LR4 SMF 40GBASE-LR4 2 x 40GBASE-SR4 MMF Dual 40GBASE-SR4 8 x 0GBASE-SR MMF Dual 40GBASE-SR4 with splitter Table 0: Port speeds supported by Xena M2CFP40 00 Gbps LR4 Excelight (Sumitomo) SCF000L4 00 Gbps SR0 Reflex Photonics CF-X2 00 Gbps SR0 Finisar FTLC828SCNM Excelight (Sumitomo) 00G CFP4 00GBASE-LR4 Innolight 00G QSFP28 00GBASE- LR4 Finisar 00G CXP 00GBASE- SR0 Figure 4: Examples of transceivers available from Xena 2

13 P/Ns Description Wave length Connector Reach Cable type 00 Gbps CFP CF-X2 (SR0) Reflex Photonics 00G CFP 00GBASE-SR0 850 nm MPO 00 m MMF FTLC828SCNM (SR0) Finisar 00G CFP 00GBASE-SR0 850 nm MPO 00 m MMF FTLC82R (LR4) Finisar 00G CFP 00GBASE-LR4 30 nm LC 0 km SMF SCF00-L4 (LR4) Excelight (Sumitomo) 00G CFP 00GBASE-LR4 30 nm LC 0 km SMF 00 Gbps CFP4 SFF400L4LNGG0B (LR4) Excelight (Sumitomo) 00G CFP4 00GBASE- LR4 30 nm LC 0 km SMF FTLC94RENM (SR4) Finisar 00G CFP4 00GBASE-SR4 850 nm MPO 00 m MMF FTLC4RDNL (LR4) Finisar 00G CFP4 00GBASE-LR4 30 nm LC 0 km SMF 00 Gbps QSFP28 TR-FC85S Innolight 00G QSFP28 00GBASE-SR4 850 nm MPO 00 m MMF TR-FC3L Innolight 00G QSFP28 00GBASE-LR4 30 nm LC 0 km SMF 00 Gbps CXP FTLD0CEC Finisar 00G CXP 00GBASE-SR0 850 nm MPO 00 m MMF 40 Gbps CFP CF-X08 (2 x SR4) Reflex Photonics 2x40G CFP Dual 40GBASE-SR4 850 nm MPOx2 00 m MMF CF-X04 (SR4) Reflex Photonics 40G CFP 40GBASE-SR4 850 nm MPO 00 m MMF FTLQ88EBLM (SR4) Finisar 40G CFP 40GBASE-SR4 850 nm MPO 00 m MMF 40 Gbps QSFP+ AFBR-79EIDZ Avago 40G QSFP+ 40GBASE-SR4 850 nm MPO 00 m MMF AFCT-88EEPZ Avago 40G QSFP+ 40GBASE-LR4 30 nm LC 0 km SMF FTL40QE2C Finisar 40G QSFP+ 40GBASE-SR4 850 nm MPO 00 m MMF FTL4CQEC Finisar 40G QSFP+ 40GBASE-LR4 30 nm LC 0 km SMF TR-IQ3L Innolight 4x0G QSFP+ 4x0GBASE-LR4 Parallel Single Mode (PSM) 30 nm MPO 0 km SMF 0 Gbps XFP SXP300SX Excelight (Sumitomo) 0G XFP 0GBASE-SR 850 nm LC 300 m MMF SXP300LX Excelight (Sumitomo) 0G XFP 0GBASE-LR 30 nm LC 0 km SMF SXP300EX-M Excelight (Sumitomo) 0G XFP 0GBASE-ER 550 nm LC 40 km SMF 0 Gbps SFP+ FTLX8573D3BT Finisar 0G SFP+ 0GBASE-SR 850 nm LC 300 m MMF SPP5300LR-GL Excelight (Sumitomo) 0G SFP+ 0GBASE-LR 30 nm LC 0 km SMF SPP500ER-GL Excelight (Sumitomo) 0G SFP+ 0GBASE-ER 550 nm LC 40 km SMF Table : 00G to 0G transceivers available from Xena 3

14 Connector MQSFP28SFP28 MCFP4QSFP28CXP MQSFP28CXP MCFP00 M2CFP40 M2QSFP+ M2QSFP0 SR4-4xLC ism4-4xlc SR4-LOOP SR0-2xSR4 SR0-2xLC SR0-LOOP SR4-Trunk SR0-Trunk APPLICATION NOTE WHAT GOES WHERE? Table 2 and 3 shows how transceivers available from Xena can be used with Xena 00 G and 40 G test modules and with cables and splitters. Xena Test Modules Cables and splitters 00 Gbps CFP CF-X2 (SR0) MPO FTLC828SCNM (SR0) MPO FTLC82R (LR4) LC SCF00-L4 (LR4) LC 00 Gbps CFP4 SFF400L4LNGG0B (LR4) LC FTLC94RENM (SR4) MPO FTLC4RDNL (LR4) LC 00 Gbps QSFP28 TR-FC85S (SR4) MPO TR-FC3L (LR4) LC 00 Gbps CXP FTLD0CEC (SR0) MPO 40 Gbps CFP CF-X08 (2 x SR4) MPOx2 CF-X04 (SR4) MPO FTLQ88EBLM (SR4) MPO Table 2: Transceivers, Xena 00/40 G test modules, cables and splitters 4

15 Connector MQSFP28SFP28 MCFP4QSFP28CXP MQSFP28CXP MCFP00 M2CFP40 M2QSFP+ M2QSFP0 SR4-4xLC ism4-4xlc SR4-LOOP SR0-2xSR4 SR0-2xLC SR0-LOOP SR4-Trunk SR0-Trunk APPLICATION NOTE Xena Test Modules Cables and splitters 40 Gbps QSFP+ AFBR-79EIDZ (SR4) MPO AFCT-88EEPZ (LR4) LC FTL40QE2C (SR4) MPO FTL4CQEC (LR4) LC TR-IQ3L (LR4) MPO 0 Gbps SFP+ FTLX8573D3BT LC SPP5300LR-GL LC SPP500ER-GL LC 00 Gbps QSFP28 AOCs and DACs FCBN425QBC05 (AOC) 200LF (DAC) 2030LF (DAC) 4050LF (DAC) Table 3: Transceivers, Xena 00/40 G test modules, cables and splitters CONFIGURING XENA 00 G AND 40 G TEST MODULES The first step in configuring the Xena 00 G and 40 G test modules is to select and reserve the test module in XenaManager-2G. In the example in this section the module used is the tri-media test module MCFP4QSFP28CXP, which supports CFP4, QSFP28 and CXP transceivers. Select the module in the XenaManager-2G Testbed explorer window, right-click on it and Reserve Module. 5

16 Figure 5: Reserve module Select the Resource Properties tab; you will now see the module properties. Next step is to select the media to be used for the test; in the example CXP is selected from the drop-down menu. Figure 6: Select Media configuration Finally, the speeds to be used for the test needs to be selected; in this case 2 x 40G is selected from the port configuration drop-down menu. 6

17 Figure 7: Select port configuration In the XenaManager-2G Testbed explorer window, you now see two 40GBASE-SR4 test ports as shown in figure 8. Figure 8: Two 40GBASE-SR4 test ports in the XenaManager-2G Testbed explorer window You can now reserve and configure the 40 Gbps ports as required. When the tester is configured to operate in 2 x 40 Gbps port speed mode, the Xena tester operate as two fully independent 40 Gbps ports, corresponding to the two logical test ports shown in figure 8. By using an optical splitter like the SR0-2xSR4 splitter cassette, the two 40 Gbps Ethernet interfaces can be made available through two standard 40 Gbps MPO2 connectors. The MPO2 connectors will act as two 40GBASE-SR4 (QSFP+) transceivers. 7

18 Figure 9: Change speed selection to 8 x 0G You can also make the CXP transceiver in the MCFP4QSFP28CXP test module act as 8 independent 0 Gbps ports. To do that, the speed setting in the must be changed to 8 x 0G in the Module Properties (see figure 9). The XenaManager-2G Testbed explorer window will change in accordance with the new setting. Figure 20: Eight 0GBASE-iSR4 test ports in the XenaManager-2G Testbed explorer window You can now reserve and configure the 0 Gbps ports as required. 8

19 To make the eight 0 Gbps test ports physically available you can use the SR0-2xSR4 splitter cassette mentioned above and connect two optical splitter cables (SR4 MTP(F) <-> 4 x LC). As an alternative, you can use an optical splitter cable (SR0 MTP(F)<-> 2 x LC) connected directly to the MPO/MTP connector on the CXP transceiver. SR0 <-> 2 X LC MMF SPLITTER CABLE When using the SR0 <-> 2 x LC MMF splitter cable, the 8 x 0 Gbps test ports are mapped to the 2 LC connectors as illustrated in table 4. Table 4 also shows how 2 x 40 Gbps test ports will be mapped to the 2 LC connectors. In both cases, all the eight 0 Gbps ports must be connected to the device under test. If the DUT has less than eight 0 Gbps ports, the redundant 0 Gbps ports must be connected with optical loop cables, or connected port-to-port using a LC-assembly link between the ports. Test Ports Cable LC Numbering scheme: Cable LC Numbering scheme: 40G 0G # - #2 #0 - #9, #A, #B 0 Cable LC #2 Cable LC #0 0 Cable LC #3 Cable LC # 2 Cable LC #4 Cable LC #2 3 Cable LC #5 Cable LC #3 4 Cable LC #7 Cable LC #5 5 Cable LC #8 Cable LC #6 6 Cable LC #9 Cable LC #7 7 Cable LC #0 Cable LC #8 Comment: Cable LC #, #6, #, #2 are not connected (unused) Cable LC #4, #9, #A, #B are not connected (unused) Table 4: SR0 -> 2 x LC MMF cable port mapping SR4 <-> 4 X LC AND ISM4 <-> 4 X LC SPLITTER CABLES When using the SR4 <-> 4 x LC and ism4 <-> 4 x LC splitter cables, the labels on the LC end of the cables will show the number of the related test port. 9

DELL EMC NETWORKING TRANSCEIVERS AND CABLES

DELL EMC NETWORKING TRANSCEIVERS AND CABLES DELL EMC NETWORKING TRANSCEIVERS AND CABLES Features and benefits Hot-swappable for simplified maintenance (no power-down required for installation or replacement) Some of the smallest and lowestpower

More information

Optics Modules and Cables Data Sheet

Optics Modules and Cables Data Sheet Optics Modules and Cables Data Sheet Key Features Deployment flexibility of 100GbE, 40GbE, 25GbE, 10GbE or 1GbE modules Smallest and lowest power SFP optic module form factor for 1GbE, 10GbE and 25GbE

More information

Cisco 100GBASE QSFP-100G Modules

Cisco 100GBASE QSFP-100G Modules Data Sheet Cisco 100GBASE QSFP-100G Modules Product Overview The Cisco 100GBASE Quad Small Form-Factor Pluggable (QSFP) portfolio offers customers a wide variety of high-density and low-power 100 Gigabit

More information

Cisco 100GBASE QSFP-100G Modules

Cisco 100GBASE QSFP-100G Modules Data Sheet Cisco 100GBASE QSFP-100G Modules Product Overview The Cisco 100GBASE Quad Small Form-Factor Pluggable (QSFP) portfolio offers customers a wide variety of high-density and low-power 100 Gigabit

More information

ExtremeSwitching TM. 100Gb Ethernet QSFP28 Transceivers and Cables. Product Overview. Data Sheet. Highlights. 100Gb Ethernet QSFP28 SR4 MMF

ExtremeSwitching TM. 100Gb Ethernet QSFP28 Transceivers and Cables. Product Overview. Data Sheet. Highlights. 100Gb Ethernet QSFP28 SR4 MMF Data Sheet Highlights Compact Quad Small Form-factor Pluggable (QSFP28) products for high density 100Gb Ethernet applications Hot swappable, field serviceable modular interfaces for Extreme Networks switches

More information

Arista 400G Transceivers and Cables: Q&A

Arista 400G Transceivers and Cables: Q&A Arista 400G Transceivers and Cables: Q&A What are the benefits of moving to 400G technology? 400G Transceivers and Cables Q&A Arista s 400G platforms allow data centers and high-performance computing environments

More information

WHITE PAPER THE CASE FOR 25 AND 50 GIGABIT ETHERNET WHITE PAPER

WHITE PAPER THE CASE FOR 25 AND 50 GIGABIT ETHERNET WHITE PAPER THE CASE FOR 25 AND 50 GIGABIT ETHERNET OVERVIEW The demand for cloud-based solutions has grown rapidly, leaving many datacenters hungry for bandwidth. This has created a demand for cost-effective solutions

More information

Arista 7500 Series Interface Flexibility

Arista 7500 Series Interface Flexibility Arista 7500 Series Interface Flexibility Today s large-scale virtualized datacenters and cloud networks require a mix of 10Gb, 25Gb, 40Gb, 50Gb and 100Gb Ethernet interface speeds able to utilize the widest

More information

Cisco 40GBASE QSFP Modules

Cisco 40GBASE QSFP Modules Data Sheet Cisco 40GBASE QSFP Modules Product Overview The Cisco 40GBASE QSFP (Quad Small Form-Factor Pluggable) portfolio offers customers a wide variety of high-density and low-power 40 Gigabit Ethernet

More information

Dell Networking Optics and Cables Connectivity Guide

Dell Networking Optics and Cables Connectivity Guide Dell Networking and Cables Connectivity Guide 1 Gigabit Ethernet (1GbE) 10 Gigabit Ethernet (10GbE) 40 Gigabit Ethernet (40GbE) 100 Gigabit Ethernet (100GbE) Fibre Channel Networking I/O Connectivity Options

More information

Plexxi HCN Compatibility Matrix

Plexxi HCN Compatibility Matrix Plexxi HCN Compatibility Matrix Document Version 9.1 December 15, 2017 100 Innovative Way - Suite 3322 Nashua, NH 03062 Tel. +1.888.630.PLEX (7539) www.plexxi.com Legal Notices The information contained

More information

Cisco 25G Transceivers and Cables Enable 25 Gigabit Ethernet over a Fiber or Copper Cable

Cisco 25G Transceivers and Cables Enable 25 Gigabit Ethernet over a Fiber or Copper Cable Cisco s and Cables Enable 25 Gigabit Ethernet over a Fiber or Copper Cable Cisco s transceivers and cables enable 25 Gigabit Ethernet for next generation switch and server applications Optimal choices

More information

Future Datacenter Interfaces Based on Existing and Emerging Technologies

Future Datacenter Interfaces Based on Existing and Emerging Technologies Future Datacenter Interfaces Based on Existing and Emerging Technologies Summer Topicals IEEE Photonics Society Waikoloa, Hawaii 8-10 July 2013 Chris Cole Outline 10G Multi-link 10G 40G Serial 40G 100G

More information

Optical Trends in the Data Center. Doug Coleman Manager, Technology & Standards Distinguished Associate Corning Optical Communications

Optical Trends in the Data Center. Doug Coleman Manager, Technology & Standards Distinguished Associate Corning Optical Communications Optical Trends in the Data Center Doug Coleman Manager, Technology & Standards Distinguished Associate Corning Optical Communications Telecom 2017 Corning Restricted Incorporated 2 Server Access Switch

More information

OFC/NFOEC 2011 Interoperability Demonstration

OFC/NFOEC 2011 Interoperability Demonstration OFC/NFOEC 2011 Interoperability Demonstration March 7, 2011 1. Overview The Ethernet Alliance has twelve members participating in the OFC/NFOEC 2011 demonstration. The participating companies include:

More information

Roadmap to 400 Gigabit Ethernet over Multimode Fiber WHITEPAPER

Roadmap to 400 Gigabit Ethernet over Multimode Fiber WHITEPAPER Roadmap to 400 Gigabit Ethernet over Multimode Fiber WHITEPAPER The unprecedented exponential growth of information technology (IT) data is not a new finding. What is new is that there is now an end in

More information

Optics Modules and Cables Data Sheet

Optics Modules and Cables Data Sheet Key Features Deployment flexibility of 100GbE, 40GbE, 10GbE or 1GbE modules Smallest and lowest power 10GbE optic module form factor Hot swappable to maximize uptime and simplify serviceability SFP+ Optical

More information

ARISTA WHITE PAPER Arista 7500E Series Interface Flexibility

ARISTA WHITE PAPER Arista 7500E Series Interface Flexibility ARISTA WHITE PAPER Arista 7500E Series Interface Flexibility Introduction: Today s large-scale virtualized datacenters and cloud networks require a mix of 10Gb, 40Gb and 100Gb Ethernet interface speeds

More information

Ethernet 100G and Beyond

Ethernet 100G and Beyond Ethernet 100G and Beyond Steve Jones Phone: +44 7900 881729 steve.jones@hubersuhner.com www.hubersuhner.com www.cubeoptics.com blog.cubeoptics.com We don t want this to be you 2 Global Data Center Traffic

More information

A Fork in the Road OM5 vs. Single-Mode in the Data Center. Gary Bernstein, Sr. Director, Product Management, Network Solutions

A Fork in the Road OM5 vs. Single-Mode in the Data Center. Gary Bernstein, Sr. Director, Product Management, Network Solutions A Fork in the Road OM5 vs. Single-Mode in the Data Center Gary Bernstein, Sr. Director, Product Management, Network Solutions Outline Definition of Enterprise and Cloud Data Centers The Growth of Cloud

More information

Pluggable Transceivers Industry standard Pluggable Transceivers and Direct Attach Cables

Pluggable Transceivers Industry standard Pluggable Transceivers and Direct Attach Cables DATASHEET Pluggable Transceivers Industry standard Pluggable Transceivers and Direct Attach Cables Product Overview Modular Ethernet interfaces from 100Mbps to 40Gbps Support for a large variety of cable

More information

40G and 100G Products

40G and 100G Products 40G and 100G Products QSFP+ esr4 QSFP+ 40G extended range transceiver, in excess of 300m QSFP-40G-SR4 Application The Prolabs QSFP+ esr4 transceiver has been designed to reach distances which can be up

More information

DC Network Connectivity

DC Network Connectivity DC Network Connectivity Options & Optimizing TCO Rakesh SAMBARAJU - Application Engineer Nexans Data Center Solutions Agenda l Part I Ethernet Standards and Technologies Ø Current Ethernet Standards Ø

More information

Overview Brochure Direct attach and active optical cables

Overview Brochure Direct attach and active optical cables Overview Brochure Direct attach and active optical cables Contact us on: Tel: 01189 122 980 Email: sales@cabcon.co.uk www.sterlingcablingsolutions.co.uk Contents High Speed Cables and Transceivers page

More information

Solutions Guide. Pluggable Optics for the Data Center

Solutions Guide. Pluggable Optics for the Data Center Solutions Guide Pluggable Optics for the Data Center Pluggable Optics for the Data Center The data center ecosystem is going through unprecedented growth and innovation as new players, new business models

More information

Cisco 10GBASE SFP+ Modules

Cisco 10GBASE SFP+ Modules Cisco 10GBASE SFP+ Modules Product Overview The Cisco 10GBASE SFP+ modules (Figure 1) offer customers a wide variety of 10 Gigabit Ethernet connectivity options for data center, enterprise wiring closet,

More information

Cisco MDS 9000 Family Pluggable Transceivers

Cisco MDS 9000 Family Pluggable Transceivers Cisco MDS 9000 Family Pluggable Transceivers The Cisco Small Form-Factor Pluggable (), and X2 devices for use on the Cisco MDS 9000 Family are hot-swappable transceivers that plug into ports on the Cisco

More information

Solutions Guide. Pluggable Optics for the Data Center

Solutions Guide. Pluggable Optics for the Data Center Solutions Guide Pluggable Optics for the Data Center Pluggable Optics for the Data Center The data center ecosystem is going through unprecedented growth and innovation as new players, new business models

More information

ETHERNET OPTICS TODAY: 25G NRZ

ETHERNET OPTICS TODAY: 25G NRZ ETHERNET OPTICS TODAY: 25G NRZ THE STATE OF ETHERNET OPTICS PANEL Brad Smith, Director of Marketing, LinkX Interconnects, Mellanox March 23, 2016 OFC 2016 Anaheim, CA BradS@Mellanox.com 1GBASE-T CAT5 is

More information

Data Center Connectivity

Data Center Connectivity Data Center Connectivity Active Optical Cable 40G QSFP+ to QSFP+ Full Duplex 4 Channel 850nm Parallel Active Optical Cable Cable Length:1m/2m/5m/10m/20m/30m/50m Low power consumption: less than 1.5 W per

More information

Trends in Testing Data Center Infrastructure. Ed Gastle VIAVI Solutions

Trends in Testing Data Center Infrastructure. Ed Gastle VIAVI Solutions Trends in Testing Data Center Infrastructure Ed Gastle VIAVI Solutions Agenda INTRODUCTION Modern Data Center Architecture Historically Enterprise has been a 3 tier topology Core, Aggregation, Access Cloud

More information

The Arista Universal transceiver is the first of its kind 40G transceiver that aims at addressing several challenges faced by today s data centers.

The Arista Universal transceiver is the first of its kind 40G transceiver that aims at addressing several challenges faced by today s data centers. ARISTA WHITE PAPER QSFP-40G Universal Transceiver The Arista Universal transceiver is the first of its kind 40G transceiver that aims at addressing several challenges faced by today s data centers. Increased

More information

HPE FlexNetwork port 10GbE SFP/SFP+/4-port 40GbE QSFP+ M2SG Module - LSUM2TGS32QSSG0(JH432A)

HPE FlexNetwork port 10GbE SFP/SFP+/4-port 40GbE QSFP+ M2SG Module - LSUM2TGS32QSSG0(JH432A) HPE FlexNetwork 10500 32-port 10GbE SFP/SFP+/4-port 40GbE QSFP+ M2SG Module - LSUM2TGS32QSSG0(JH432A) 1 Card identifier The card identifier LSUM2TGS32QSSG0 is at the upper right corner of the front panel.

More information

100G and Beyond: high-density Ethernet interconnects

100G and Beyond: high-density Ethernet interconnects 100G and Beyond: high-density Ethernet interconnects Kapil Shrikhande Sr. Principal Engineer, CTO Office Force10 Networks MIT MicroPhotonics Center Spring Meeting April 5, 2011 [ 1 ] Ethernet applications

More information

Fiber Optic Cabling Systems for High Performance Applications

Fiber Optic Cabling Systems for High Performance Applications Fiber Optic Cabling Systems for High Performance Applications BICSI Conference Bangkok, Thailand 17-18 November 2016 Nicholas Yeo, RCDD/NTS/DCDC Data Center Trends Computing evolution Cloud computing Servers

More information

SUREPORT TM Transceivers for Cisco Platforms

SUREPORT TM Transceivers for Cisco Platforms SUREPORT TM Transceivers for Cisco Platforms Dual SFP Dual SFP+ Single SFP Single SFP+ QSFP+ Dual XFP Single XFP CWDM SFP CWDM SFP+ DWDM SFP DWDM SFP+ CWDM XFP DWDM XFP Copper (RJ-45) SFP Dual X2 CWDM

More information

Everything you wanted to know about cabling, but were afraid to ask

Everything you wanted to know about cabling, but were afraid to ask Everything you wanted to know about cabling, but were afraid to ask Join the teleconference To receive a call back, click Communicate/Teleconference/Join Teleconference. In the pop-up window, enter your

More information

Delivering100G and Beyond. Steve Jones Phone: blog.cubeoptics.

Delivering100G and Beyond. Steve Jones Phone: blog.cubeoptics. Delivering100G and Beyond Steve Jones Phone: +44 7900 881729 steve.jones@hubersuhner.com www.hubersuhner.com www.cubeoptics.com blog.cubeoptics.com We don t want this to be you 2 100G Access/Metro Figures

More information

100GE 500m SMF Parallel and WDM links

100GE 500m SMF Parallel and WDM links 00GE 500m SMF Parallel and WDM links K. Shrikhande, Dell June, 203 802.3bm SMF Ad Hoc presentation This talk Results from an (independent) SMF link cost analysis Similar methodology to prior work in 802.3bm

More information

Ethernet evolution: what s new and what s next

Ethernet evolution: what s new and what s next Ethernet evolution: what s new and what s next Greg Hankins European Peering Forum 2016 1 Nokia 2016 EPF 2016 2016/09/19 I ve been giving presentations about Ethernet developments

More information

Supported Hardware Components

Supported Hardware Components This chapter contains information about the supported hardware components on the Cisco ASR 1001-HX Router and Cisco ASR 1002-HX Router, and contains the following sections: Supported EPAs, page 1 Supported

More information

Cisco 10GBASE SFP+ Modules

Cisco 10GBASE SFP+ Modules Data Sheet Cisco 10GBASE SFP+ Modules Product Overview The Cisco 10GBASE SFP+ modules (Figure 1) offer customers a wide variety of 10 Gigabit Ethernet connectivity options for data center, enterprise wiring

More information

100 GIGABIT ETHERNET. So we ve got 802.3ba, now what do we do with it? Chris Bull Service Provider ANZ

100 GIGABIT ETHERNET. So we ve got 802.3ba, now what do we do with it? Chris Bull Service Provider ANZ 100 GIGABIT ETHERNET Chris Bull Service Provider Systems Engineer ANZ So we ve got 802.3ba, now what do we do with it? Standards How we got to 802.3ba 2011 Brocade Communications Systems, Inc. 2 Summary

More information

ProLabs Introduction. Tuesday 11th October,

ProLabs Introduction. Tuesday 11th October, ProLabs Introduction Tuesday 11th October, 2016 www.prolabs.com 1 What products do ProLabs sell? OEM Compatibility verified and tested in target equipment Transceivers DACs & AOCs Media Converters Mux/DeMux

More information

400GE at the Cost of 4 x 100GE

400GE at the Cost of 4 x 100GE 400GE at the Cost of 4 x 100GE Jeffery J. Maki Distinguished Engineer, Optical Juniper Networks, Inc. May 17, 2013 400 Gb/s Ethernet Study Group Victoria BC, Canada, May 2013 400GE over SMF by using the

More information

ProLabs new product releases

ProLabs new product releases ProLabs new product releases XENPAK/X2 Converter Pluggable XENPAK or X2 body with open SFP+ slot XENPAK-CONVERTER Application This is ideal for customers who have already invested heavily in Xenpak / X2

More information

Untangled: Improve Efficiency with Modern Cable Choices. PRESENTATION TITLE GOES HERE Dennis Martin President, Demartek

Untangled: Improve Efficiency with Modern Cable Choices. PRESENTATION TITLE GOES HERE Dennis Martin President, Demartek Untangled: Improve Efficiency with Modern Cable Choices PRESENTATION TITLE GOES HERE Dennis Martin President, Demartek Agenda About Demartek Why Discuss Cables and Connectors? Cables Copper Fiber-Optic

More information

New Data Center and Transport Interconnect Technology

New Data Center and Transport Interconnect Technology New Data Center and Transport Interconnect Technology Tom McDermott Fujitsu Network Communications, Inc. October 30, 2014 Changing Requirements Datacenters are expanding in size. Continued need for 100m

More information

BROCADE OPTICS FAMILY

BROCADE OPTICS FAMILY DATA SHEET www.brocade.com BROCADE OPTICS FAMILY IP NETWORK Highly Reliable, Brocade-Qualified Optics HIGHLIGHTS Rigorously tested for performance and reliability by Brocade Hot-swappable flexibility in

More information

Data Center: First-Time Right Acceptance Testing Steps for Certification and Troubleshooting - Intra & Inter-connect. Nicholas Gagnon EXFO

Data Center: First-Time Right Acceptance Testing Steps for Certification and Troubleshooting - Intra & Inter-connect. Nicholas Gagnon EXFO Data Center: First-Time Right Acceptance Testing Steps for Certification and Troubleshooting - Intra & Inter-connect Nicholas Gagnon EXFO Data Center today Source: EXFO Global Data Center Traffic by Destination

More information

Doug Coleman Manager, Technology & Standards Distinguished Associate Corning Optical Communications

Doug Coleman Manager, Technology & Standards Distinguished Associate Corning Optical Communications Optical Trends in the Data Center Doug Coleman Manager, Technology & Standards Distinguished Associate Corning Optical Communications Higher speeds Higher density Higher reliability Lower capex Lower opex

More information

Expanding your network horizons

Expanding your network horizons Datacenter Interconnect Lösungen von 1G bis 100G - Brocade- und Cisco-zertifizierte FibreChannel-Lösungen bis 32G - SAN und IP-Interconnect - Längenrestriktionen bei der Übertragung - 100G ist das neue

More information

Brocade Ethernet Optics Family

Brocade Ethernet Optics Family DATA SHEET Brocade Ethernet Optics Family Highlights Rigorously tested for performance and reliability by Brocade Hot-swappable flexibility in the field for greater ease and lower total cost of ownership

More information

Testing Parallel Optics

Testing Parallel Optics White Paper Testing Parallel Optics Author: Ed Gastle VIAVI Solutions To accommodate the relentless need for speed, driven by mobile devices, watching videos online and uploading and sharing content, network

More information

Pluggable Transceivers, Module Connectors

Pluggable Transceivers, Module Connectors Pluggable Transceivers, page 1 Module Connectors, page 7 Pluggable Transceivers This section provides brief descriptions of the pluggable transceivers that can be installed in the switch modules and supervisor

More information

ARISTA 7500R/7500E/7300X Connectivity Guide CABLExpress 1. ARISTA 7500R/7500E/7300X Connectivity Guide

ARISTA 7500R/7500E/7300X Connectivity Guide CABLExpress 1. ARISTA 7500R/7500E/7300X Connectivity Guide ARISTA 7500R/7500E/7300X Connectivity Guide CABLExpress 1 ARISTA 7500R/7500E/7300X Connectivity Guide How do you protect and improve the functionality of your critical processes? You have to Respect Layer

More information

Cisco 100BASE-X Small Form-Factor Pluggable Modules for Fast Ethernet Applications

Cisco 100BASE-X Small Form-Factor Pluggable Modules for Fast Ethernet Applications Data Sheet Cisco 100BASE-X Small Form-Factor Pluggable Modules for Fast Ethernet Applications Product Overview The Cisco 100BASE-X Small Form-Factor Pluggable (SFP) device (Figure 1) is a hot-swappable

More information

PREPARING FOR FUTURE STRUCTURED CABLING REQUIREMENTS IN THE DATA CENTER: 40/100 GIGABIT ETHERNET AND BEYOND

PREPARING FOR FUTURE STRUCTURED CABLING REQUIREMENTS IN THE DATA CENTER: 40/100 GIGABIT ETHERNET AND BEYOND PREPARING FOR FUTURE STRUCTURED CABLING REQUIREMENTS IN THE DATA CENTER: 40/100 GIGABIT ETHERNET AND BEYOND Cindy Montstream, RCDD/NTS, EE, CPLP Director of elearning and Standards DATA COMMUNICATIONS

More information

100 GBE - WHAT'S NEW AND WHAT'S NEXT

100 GBE - WHAT'S NEW AND WHAT'S NEXT Here is more rough stuff on the ALTO ALOHA network. Memo sent by Bob Metcalfe on May 22, 1973. 100 GBE - WHAT'S NEW AND WHAT'S NEXT Greg Hankins UKNOF25 UKNOF25 2013/04/18 40 Gigabit

More information

Cisco 25GBASE SFP28 Modules

Cisco 25GBASE SFP28 Modules Data Sheet Cisco 25GBASE SFP28 Modules Product Overview The Cisco 25GBASE SFP28 (Small Form-Factor Pluggable) portfolio offers customers a wide variety of highdensity and low-power 25 Gigabit Ethernet

More information

Fiber in Data Centers What s Next? Srinivasan B, RCDD

Fiber in Data Centers What s Next? Srinivasan B, RCDD Fiber in Data Centers What s Next? Srinivasan B, RCDD Hubbell Fiber Systems 10G / 40G / 100G / 400G Standards, Applications and Practices Agenda Part 1: Current Technologies Standards Review IEEE 802.3:

More information

Arista 40G Cabling and Transceivers: Q&A

Arista 40G Cabling and Transceivers: Q&A Arista 40G Cabling and Transceivers: Q&A 40G Cabling Technical Q&A Document 40Gigabit Cables and Transceivers Q. What 40G cables and transceivers are available from Arista? A. Arista supports a full range

More information

SLIDE 1 - COPYRIGHT G. Across the country, Across the Data Centre. Tim Rayner. Optical Engineer, AARNet.

SLIDE 1 - COPYRIGHT G. Across the country, Across the Data Centre. Tim Rayner. Optical Engineer, AARNet. SLIDE 1 - COPYRIGHT 2015 100G Across the country, Across the Data Centre Tim Rayner Optical Engineer, AARNet Tim.Rayner@AARNet.edu.au Agenda SLIDE 2 - COPYRIGHT 2015 Review of 10G, 40G &100G Standards

More information

HIGH DENSITY DATA CENTER CABLING GUIDE. Optics DACs Cables Cable Management Fiber TAPs Media Converters

HIGH DENSITY DATA CENTER CABLING GUIDE. Optics DACs Cables Cable Management Fiber TAPs Media Converters HIGH DENSITY DATA CENTER CABLING GUIDE Optics DACs Cables Cable Management Fiber TAPs Media Converters PROVIDING MTP CABLING SOLUTIONS FOR THE SMART DATA CENTER. APPROVED NETWORKS SETS THE STANDARD The

More information

What s the technology Buzz at the 2017 Optical Fiber Communications Conference?

What s the technology Buzz at the 2017 Optical Fiber Communications Conference? 40G 100G.400G 800G? What s the technology Buzz at the 2017 Optical Fiber Communications Conference? Lylette Macdonald, RCDD Legrand Data Communications Division lylette.macdonald@legrand.us The Future

More information

Brocade Ethernet Optics Family

Brocade Ethernet Optics Family DATA SHEET Brocade Ethernet Optics Family HIGHLIGHTS Rigorously tested for performance and reliability by Brocade Hot-swappable flexibility in the field for greater ease and lower total cost of ownership

More information

The Impact of Emerging Data Rates on Layer One Fiber Cabling Infrastructures. Rick Dallmann Senior Data Center Infrastructure Architect CABLExpress

The Impact of Emerging Data Rates on Layer One Fiber Cabling Infrastructures. Rick Dallmann Senior Data Center Infrastructure Architect CABLExpress The Impact of Emerging Data Rates on Layer One Fiber Cabling Infrastructures Rick Dallmann Senior Data Center Infrastructure Architect CABLExpress 36 Years of Experience CABLExpress is a manufacturer of

More information

10GB ETHERNET SFP+ ULTRA LOW POWER SR OPTICAL TRANSCEIVER

10GB ETHERNET SFP+ ULTRA LOW POWER SR OPTICAL TRANSCEIVER OPTICAL INTERCONNECT 10GB ETHERNET SFP+ ULTRA LOW POWER SR OPTICAL TRANSCEIVER OVERVIEW FCI s TRX10GVP2010C2 10Gb/s Ethernet 850nm Multi Mode SFP+ SR Optical Transceiver is designed for datacenter networking

More information

Connector and Cable Specifications

Connector and Cable Specifications Connector Specifications, page 1 Console Port, page 3 Cables and Adapters, page 3 Connector Specifications 10/100/1000 Ports (Including PoE) All 10/100/1000 ports use standard RJ-45 connectors and Ethernet

More information

Optical Trends in the Data Center

Optical Trends in the Data Center Optical Trends in the Data Center Romeo Lazar Sales Manager, Eastern Europe Corning Optical Communications EMEA September 2016 Agenda Agenda Corning overview Data Center Server and Switch Trends Standards

More information

CISCO WDM SERIES OF CWDM PASSIVE DEVICES

CISCO WDM SERIES OF CWDM PASSIVE DEVICES DATA SHEET CISCO WDM SERIES OF CWDM PASSIVE DEVICES Cisco Systems introduces its second generation of coarse wavelength-division multiplexing (CWDM) passive devices boasting increased functions and improved

More information

ArubaOS-Switch and ArubaOS-CX Transceiver Guide

ArubaOS-Switch and ArubaOS-CX Transceiver Guide ArubaOS-Switch and ArubaOS-CX Transceiver Guide Part Number: 5200-3362c Published: March 2018 Edition: 4 Copyright 2017, 2018 Hewlett Packard Enterprise Development LP Notices The information contained

More information

Multi-Gigabit Datacom Connectors and Cable Assemblies Market

Multi-Gigabit Datacom Connectors and Cable Assemblies Market Report No.: T 910 14 November 2014 Bishop and Associates, Inc. has just released a new four chapter, 151 page research report providing a qualitative and quantitative analysis of the Multi Gigabit Datacom

More information

Tim Takala RCDD. Vice President Field Application Engineer APAC. Mobility is Driving Changing Network Architectures & Transceiver Evolutions

Tim Takala RCDD. Vice President Field Application Engineer APAC. Mobility is Driving Changing Network Architectures & Transceiver Evolutions Tim Takala RCDD Vice President Field Application Engineer APAC Mobility is Driving Changing Network Architectures & Transceiver Evolutions 5TOP TRENDS SHAPING NETWORKS 1. Mobility 2. Connected Devices

More information

Adrian Young Leviton Network Solutions

Adrian Young Leviton Network Solutions Adrian Young Leviton Network Solutions In This Session Multimode fiber types How many fibers do I need for my application? Future IEEE and non IEEE applications Will my existing fiber plant support these?

More information

NETWORKING/ DATACOMM QUICK SKU FINDER

NETWORKING/ DATACOMM QUICK SKU FINDER NETWORKING/ DATACOMM QUICK SKU FINDER TD@C2G.COM Simplified Connectivity Simplified Connectivity combines our technical support services, products, and industry leading customer advocacy to create a comprehensive

More information

Optical Fiber Networks: Industry. and New Options for Networks

Optical Fiber Networks: Industry. and New Options for Networks Optical Fiber Networks: Industry Trends, Application Influences and New Options for Networks Herbert V Congdon II, PE Manager, Standards & Technology Tyco Electronics AMP NETCONNECT Solutions Preview Deciding

More information

400GE 200GE 100GE XENA LAYER GE 40GE 25GE 10GE 5GE GIGABIT ETHERNET TEST PLATFORM 2.5GE 1GE

400GE 200GE 100GE XENA LAYER GE 40GE 25GE 10GE 5GE GIGABIT ETHERNET TEST PLATFORM 2.5GE 1GE XENATM 400GE 00GE 00GE 50GE 40GE 5GE GE.5GE 0GE 5GE XENA LAYER -3 GIGABIT ETHERNET TEST PLATFORM OVERVIEW Xena Layer -3 platform in a nutshell Very fast and super friendly Xena s L-3 test platform is used

More information

Cisco Small Form-Factor Pluggable Modules for Gigabit Ethernet Applications

Cisco Small Form-Factor Pluggable Modules for Gigabit Ethernet Applications Data Sheet Cisco Small Form-Factor Pluggable Modules for Gigabit Ethernet Applications The industry-standard Cisco Small Form-Factor Pluggable (SFP) Gigabit Interface Converter is a hot-swappable input/output

More information

Networking Terminology Cheat Sheet

Networking Terminology Cheat Sheet Networking Cheat Sheet YOUR REFERENCE SHEET FOR GOING WEB-SCALE WITH CUMULUS LINUX With Cumulus Linux, you can build a web-scale data center with all the scalability, efficiency and automation available

More information

High Speed Migration: Choosing the right multimode multi-fiber push on (MPO) system for your data center

High Speed Migration: Choosing the right multimode multi-fiber push on (MPO) system for your data center High Speed Migration: Choosing the right multimode multi-fiber push on (MPO) system for your data center Table of Contents Introduction 3 Figure 1 - The Ethernet road map 3 Planning considerations 4 Fiber

More information

Active Optical Cable. Optical Interconnection Design Innovator 25G SFP28 AOC 10G SFP+ AOC. Shenzhen Gigalight Technology Co.,Ltd.

Active Optical Cable. Optical Interconnection Design Innovator 25G SFP28 AOC 10G SFP+ AOC. Shenzhen Gigalight Technology Co.,Ltd. Optical Interconnection Design Innovator Active Optical Cable Shenzhen Gigalight Technology Co.,Ltd. Add: 17F, Zhongtai Nanshan Zhujue Building, 4269 Dongbin Road, Nanshan District, Shenzhen, Guangdong

More information

Cabling Solutions for Nexus 9000 Switches With Dual-Rate 40/100G BiDi Transceiver and Panduit Connectivity

Cabling Solutions for Nexus 9000 Switches With Dual-Rate 40/100G BiDi Transceiver and Panduit Connectivity Cabling Solutions for Nexus 9000 Switches With Dual-Rate 40/100G BiDi Transceiver and Panduit Connectivity Introduction Virtualization and cloud technologies have applied an incredible amount of pressure

More information

HPE LSWM124XG2Q (JH181A) & LSWM124XG2QL (JH180A) Interface Modules User Guide

HPE LSWM124XG2Q (JH181A) & LSWM124XG2QL (JH180A) Interface Modules User Guide HPE LSWM124XG2Q (JH181A) & LSWM124XG2QL (JH180A) Interface Modules User Guide Part number: 5998-7150t Introduction HPE description Alias JH181A HPE 5930 24-port SFP+ and 2-port QSFP+ with MACsec Module

More information

HPE LSWM124XGT2Q Interface Module (JH182A) User Guide

HPE LSWM124XGT2Q Interface Module (JH182A) User Guide HPE LSWM124XGT2Q Interface Module (JH182A) User Guide Part number: 5998-7152t Introduction Product HPE description Alias JH182A HPE 5930 24-port 10GBASE-T and 2-port QSFP+ with MACsec Module LSWM124X GT2Q

More information

40 Gbit/s Small-Form Low-Power Optical Transceiver

40 Gbit/s Small-Form Low-Power Optical Transceiver FEATURED TOPIC 4 Gbit/s Small-Form Low-Power Optical Transceiver Hideaki KAMISUGI*, Kuniyuki ISHII, Tetsu MURAYAMA, Hiromi TANAKA, Hiromi KURASHIMA, Hiroto ISHIBASHI and Eiji TSUMURA The authors have successfully

More information

MX Ring. WDM - MUX/DeMUX. MUX/DeMUX. Features Full native mode performance Optical connectors Passive model requires no power.

MX Ring. WDM - MUX/DeMUX. MUX/DeMUX. Features Full native mode performance Optical connectors Passive model requires no power. WDM - MUX/DeMUX MX20-3155 Dual Channel WDM MUX/DeMUX 5 MX20-3155 is a dual channel, passive, protocol transparent, WDM multiplexer/demultiplexer which utilizes two popular WDM lambda channels of 1310nm

More information

QSFP (Quad Small Form-factor Pluggable) Products

QSFP (Quad Small Form-factor Pluggable) Products QSFP (Quad Small Form-factor Pluggable) Products Switches Routers Host bus adapters Enterprise storage High performance computing The Quad Small Form-factor Pluggable (QSFP) product line from TE Connectivity

More information

40/100GbE MPO Fiber Optic Connectors Market Forecast : North America

40/100GbE MPO Fiber Optic Connectors Market Forecast : North America Published on Market Research Reports Inc. (https://www.marketresearchreports.com) Home > 40/100GbE MPO Fiber Optic Connectors Market Forecast 2015-2020 : North America 40/100GbE MPO Fiber Optic Connectors

More information

Cisco ASR 9000 Modular Line Card and Modular Port Adapters

Cisco ASR 9000 Modular Line Card and Modular Port Adapters Cisco ASR 9000 Modular Line Card and Modular Port Adapters In this section you will identify the following aspects of the Modular Line Card: Part number and description Location Status LEDs Part number

More information

400G PAM4 The Wave of the Future. Michael G. Furlong - Senior Director, Product Marketing

400G PAM4 The Wave of the Future. Michael G. Furlong - Senior Director, Product Marketing 400G The Wave of the Future Michael G. Furlong - Senior Director, Product Marketing mfurlong@inphi.com ECOC 2017 100G is Ramping in the Cloud 100G Now Shipping (~2H2016) Numerous Market Reports Millions

More information

40 Gigabit and 100 Gigabit Ethernet Are Here!

40 Gigabit and 100 Gigabit Ethernet Are Here! WHITE PAPER www.brocade.com High- Performance Networks 40 Gigabit and 100 Gigabit Ethernet Are Here! The 40 Gigabit and 100 Gigabit Ethernet standards were adopted by the Institute of Electrical and Electronics

More information

SFF Committee documentation may be purchased in electronic form. SFF specifications are available at ftp://ftp.seagate.com/sff. SFF Committee SFF-8024

SFF Committee documentation may be purchased in electronic form. SFF specifications are available at ftp://ftp.seagate.com/sff. SFF Committee SFF-8024 SFF Committee documentation may be purchased in electronic form. SFF specifications are available at ftp://ftp.seagate.com/sff SFF Committee SFF-8024 Specification for SFF Committee Cross Reference to

More information

APPLICATION NOTE IXIA NOVUS 25GE SPEED OPTION INDUSTRY SPECIFICATIONS AND INTEROPERABILITY OVERVIEW

APPLICATION NOTE IXIA NOVUS 25GE SPEED OPTION INDUSTRY SPECIFICATIONS AND INTEROPERABILITY OVERVIEW IXIA SPEED OPTION INDUSTRY SPECIFICATIONS AND INTEROPERABILITY OVERVIEW MARCH 23, 2017 There are two industry draft specifications that Ixia s customers are using to implement the 25-Gigabit Ethernet (25GE)

More information

The Road to 100G Xena Networks, October 2011

The Road to 100G Xena Networks, October 2011 The Road to 100G Xena Networks? xena Ixia Spirent Xena Networks? Founded in 2007 and based in Denmark. L2-L3 Gigabit Ethernet test solutions. Narrow focus = low cost (50% of competitors). World s first

More information

MPO/ MTP Parallel Optics Technology in High Speed Data Center Application

MPO/ MTP Parallel Optics Technology in High Speed Data Center Application MPO/ MTP Parallel Optics Technology in High Speed Data Center Application www.vlinkoptics.com 1 1.Data centers present and future The need for ever-greater bandwidths continues unabated. Data centers must

More information

40 and 100 Gigabit Ethernet Overview

40 and 100 Gigabit Ethernet Overview Extreme Networks White Paper 40 and 100 Gigabit Ethernet Overview Abstract This paper takes a look at the main forces that are driving Ethernet bandwidth upwards. It looks at the standards and architectural

More information

McAfee Network Security Platform

McAfee Network Security Platform Revision D McAfee Network Security Platform (M-series Transceiver Modules Reference Guide) COPYRIGHT Copyright 2018 McAfee, LLC TRADEMARK ATTRIBUTIONS McAfee and the McAfee logo, McAfee Active Protection,

More information

Installation Notes for the Catalyst 3750-X and 3560-X Network Modules

Installation Notes for the Catalyst 3750-X and 3560-X Network Modules Installation Notes for the Catalyst 3750-X and 3560-X Network Modules Published: October, 2011 This note provides the installation instructions for the Catalyst 3750-X and 3560-X network modules. Translations

More information

Overcoming the Testing Challenges of 40G and Beyond. Eric Farst Channel Sales Manager

Overcoming the Testing Challenges of 40G and Beyond. Eric Farst Channel Sales Manager Overcoming the Testing Challenges of 40G and Beyond Eric Farst Channel Sales Manager Agenda Introduction Increased demand for speed & capacity in the Enterprise/Data Center How Enterprises/Data Centers

More information