OMX-CI-RS232 Control Interface

Size: px
Start display at page:

Download "OMX-CI-RS232 Control Interface"

Transcription

1 Control Interface 970 Rev. B 0.0. Description Integrates GRAFIK 000TM, GRAFIK 000, GRAFIK 7000TM, Softswitch8, and LCP8 systems with a touchscreen or other digital equipment that supports RS communication. Provides monitoring commands that allow a touchscreen to query lighting systems to: Determine which scene is selected. Keep track of buttons pressed. Provides control commands that allow a touchscreen to operate lighting systems to: Select or sequence lighting scenes. Raise or Lower one or more zones. Lock lighting controls. Activate panic mode (lights go to full on). Simulate button actions Disable or Enable timeclock(s)

2 Specifications 970 Rev. B 0.0. Power IEC PELV/NEC Class Operating Voltage: V ma V ma Uses OMX RS Command Set Monitoring: Scene selection and scene status updates. Control: Scene selection, scene lockout, sequencing, zone lockout, zone raise/lower. System Communications and Capacity IEC PELV/NEC Class wiring connects OMX-RS Interface to Processor Panel. Multiple OMX-RS may be used. 0 ft ( m) maximum from OMX-RS Interface to PC or other RS source. Environment to 0 F (0 to 0 C). Relative humidity less than 90% non-condensing. 9 7 Dip Switch Settings Baud Rate ing Baud Up Down (On) (Off) Not used

3 970 Rev. B 0.0. Dimensions.7 in (.7 mm) Mounting Holes.7 in (9. mm). in (08. mm). in (. mm).0 in (.9 mm) Mounting. Mount the control interface directly on a wall, as shown in the Mounting Diagram, using screws (not included). When mounting, provide sufficient space for connecting cables. The unit can also be placed in the LUT-9AV-U AV rack using the screws provided with the unit. The LUT-9AV-U will hold up to four units. If conduit is desired for wiring, the LUT-x0-ENC can be used to mount one unit.. Strip in (0 mm) of insulation from wires. Each data link terminal will accept up to two 8 AWG (.0 mm ) wires.. Connect wiring as shown in the Wiring Diagram (next page). LED lights continuously (Power) and LED 7 blinks rapidly (Data Link RX) when the IEC PELV/NEC Class Data Link is installed correctly. Mounting Diagram Control Interface Wall Mounting Hole Detail Dimensions: in (mm) 0. (.) 0.8 (.) # or #8 (M or M) screw recommended (not included) Wire Strip Length in (0 mm) 0. (8.) 0.8 (.) LUT-9AV-U LUT-x0-ENC

4 RS Link Wiring 970 Rev. B 0.0. Use cable provided. Standard 9-pin serial connector plugs into RS equipment, other end connects to RS Link terminals. Must be 0 ft ( m) or less. RS Signals OMX-RS Link Terminal Signal Typical PC or A/V Equipment Pin on 9-pin Cable Common Data Out Data In No Connect No Connect Com TxD RxD IEC PELV/NEC Class Wiring Daisy-chain the Interface to the IEC PELV/NEC Class Wallstation Link that connects to the Processor Panel. Make daisy-chain connections to the IEC PELV/NEC Class Data Link terminals on the front of Interface. Do not use T-taps. Run all wires in and out of terminal block. Each terminal accepts up to two 8 AWG (.0 mm ) wires. LED lights when the IEC PELV/NEC Class Data link is installed correctly. Consult Processor Panel Specification Submittal for more details. RS Cable: maximum 0 ft ( m) COM TxD RxD To PC or AV equipment: Use the 9-pin cable provided, or follow the chart at right. RS Pin Connect Wiring Typical PC or Pin on RS Interface A/V equipment 9-pin cable Common Com Transmit TxD Receive RxD 7 RS Link Data Link (to Control Units, processors, and wallstations) DIP Switches LED : Power LED, : Unused LED : RS link TX LED : RS link RX LED : Data link TX LED 7: Data link RX

5 IEC PELV/NEC Class Terminal Connections 970 Rev. B 0.0. Two AWG (. mm ) conductors for common (terminal ) and V (terminal ). These will not fit in terminals. Connect as shown. One shielded, twisted pair 8 AWG (.0 mm ) for data link (terminals and ). Connect Drain/Shield as shown. Do not connect to Ground (Earth) or Wallstation/. Connect the bare drain wires and cut off the outside shield. Data Link: () shielded, twisted pair 8 AWG (.0 mm ) : MUX : MUX Use Lutron Cable GRX-CBL-L D: Drain/Shield () AWG (. mm ) Note: Do not connect Drain/Shield to Ground (Earth) or Wallstation/Control Interfaces. Connect the bare drain wires and cut off the outside shield. PELV (Class : USA) Power wiring: : Common : V Power () 8 AWG (.0 mm ) pigtails, in ( mm) maximum length () AWG (. mm ) Note: AWG (. mm ) conductors for Common (terminal ) and V Power (terminal ) will not fit in terminals; use 8 AWG (.0 mm ) pigtails (< in/ mm).

OMX-CI-NWK-E Control Interface

OMX-CI-NWK-E Control Interface Control Interface 369369 Rev. B 1 06.02.11 Description Integrates GRAFIK 5000TM, GRAFIK 6000, GRAFIK 7000TM, Softswitch128, and LCP128 systems with a touchscreen or other digital equipment that supports

More information

GRX-CI-RS232 Control Interface

GRX-CI-RS232 Control Interface Control Interface 369364c 1 04.07.17 Description Integrates a GRAFIK Eye Lighting and Shade Control System with a touchscreen, PC, or other digital equipment that supports RS232 communication. Provides

More information

GRX-CI-NWK-E Control Interface

GRX-CI-NWK-E Control Interface Control Interface 369362c 1 04.07.17 Description Integrates a GRAFIK Eye Lighting and Shade Control System with a touchscreen, PC, or other digital equipment that supports TCP/IP communication over Ethernet.

More information

QSE-CI-NWK-E Control Interface

QSE-CI-NWK-E Control Interface Control Interface 369373 Rev. A 1 12.16.10 Description The is a versatile integration access point for Lutron s QS-based systems. Through either RS232 or TCP/IP over Ethernet, third-party devices can control

More information

QSE-CI-DMX Control Interface

QSE-CI-DMX Control Interface Control Interface 369372 Rev. B 1 08.12.11 Description The operates either in a standalone QS system or a Quantum system. It performs different functions depending on the system in which it is operating.

More information

QSE-CI-DMX Control Interface

QSE-CI-DMX Control Interface Control Interface The performs different functions depending on the system in which it is operating. The channels (maximum of 32) are mapped to HomeWorks zones and can be programmed as 1-channel lighting,

More information

GRX-CI-NWK-E Control Interface

GRX-CI-NWK-E Control Interface Control Interface grx-ci-nwk-e 1 09.04.05 Description Integrates a GAFIK Eye Lighting & Shade Control System with a touchscreen, PC, or other digital equipment that supports TCP/IP communication over Ethernet.

More information

LUT-DMX DMX512 Control Interface

LUT-DMX DMX512 Control Interface rev dmx-1a 7.20.00 DMX512 Control Interface Lets GRAFIK Eye lighting controls operate lighting and other equipment that uses the DMX512 protocol: Strobes, fiber optic lighting, and LED-based lamps Fogger

More information

GRX-PRG Programming Control Interface

GRX-PRG Programming Control Interface grx-prg-.9.0 Programming Control Interface Description Integrates a GAFIK Eye Lighting Control System with a PC or other digital equipment that supports S communication. Provides a basic S command set

More information

EGRX-2B-SL- - 2-Button Wallstation

EGRX-2B-SL- - 2-Button Wallstation EGRX-2B-SL- - 2-Button Wallstation Top Button Bottom Button egrx-1 12.9.03 Functionality can be indicate which button was pushed last. Works with GRAFIK Eye 3000 and 4000 Series Control Units. Invokes

More information

SS-1BI-GWH-E00 1-Button Wallstation

SS-1BI-GWH-E00 1-Button Wallstation LUTON TM Softswitch128TM SS-1BI-GWH-E00 1-Button Wallstation LED ss-1 04.10.06 LUTON TM Softswitch128TM SS-2BI-GWH-E00 2-Button Wallstation ss-2 04.10.06 Off LUTON TM Softswitch128TM SS-3BI-GWH-E00 3-Button

More information

QSWA-KP5-DW- 5 Button Wallstation with Raise/Lower

QSWA-KP5-DW- 5 Button Wallstation with Raise/Lower QSWA-KP5-DW- 5 Button Wallstation with Raise/Lower Description Color / Finish Used to control one or more lighting or shades / draperies groups simultaneously. Receives up to two contact closure inputs

More information

Light Management Hub. Quantum 230 V CE Light Management Hub. Centralized Control Equipment

Light Management Hub. Quantum 230 V CE Light Management Hub. Centralized Control Equipment Quantum 69-77b 06.. Hub The Quantum light management hub provides a centralized connection point for Lutron QS devices, including Energi Savr NodeTM, GRAFIK Eye QS, Sivoia QS shades, and Lutron dimming

More information

GRAFIK 5000P / 6000P / 7000P Processor Panel

GRAFIK 5000P / 6000P / 7000P Processor Panel GRAFIK 5000P / 6000P / 7000P Processor Panel Processor panels store and/or process all of the information needed to run a GRAFIK 5000TM, GRAFIK 6000, or GRAFIK 7000TM centralized lighting control system,

More information

Wallstations for use with Grafik 3000 and 4000 Series Systems

Wallstations for use with Grafik 3000 and 4000 Series Systems Wallstations for use with Grafik 000 and 000 Series Systems NTGRX-LB NTGRX-LB-R/L NTGRX-LB9 NTGRX-LB9-R/L NTGRX-KP NTGRX-KP0 NTGRX-KP 7 8 9 Wallstation circuits are classified as Class circuits (U.S.A.)

More information

QSWE-2BN- - QSWE-2BI- - 2-Button Wallstation

QSWE-2BN- - QSWE-2BI- - 2-Button Wallstation QSWE-BN- - QSWE-BI- - -Button Wallstation Color and Codes LEDs 36973b 08.0. Description Often used in entryways to select Scene and. Large, rounded buttons are easy to use. Backlit buttons with optional

More information

Quantum Light Management Hub (QP3) for Quantum Select

Quantum Light Management Hub (QP3) for Quantum Select for Select The Quantum provides a centralized connection point for Lutron power panels and QS devices. 369423f 1 10.06.16 Features Designed to control, manage, and monitor any Energi Savr NodeTM units,

More information

product specifications d

product specifications d RadioRA 2 Repeaters extend the range of Radio Frequency () signals that are sent between dimmers, switches, keypads, visor controls, shades / draperies, and other devices. Repeaters ensure error-free communication

More information

HomeWorks QS Processor

HomeWorks QS Processor product specifications 369-376 The processor provides control and communication to system components. The Ethernet links allow communication to the software, integration with third party systems and communication

More information

LCP128 Dimming and Switching System

LCP128 Dimming and Switching System LCP128 Dimming and Switching System 369646c 1 04.19.17 System Overview LCP128 is a combination dimming and switching system that provides a complete lighting control solution. The system consists of panels

More information

IMPORTANT SAFETY INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION IMPORTANT SAFETY INSTRUCTIONS WARNING RISK OF SEVERE INJURY OR DEATH To reduce the risk of death,

More information

Energi Savr NodeTM Programming Interface

Energi Savr NodeTM Programming Interface NodeTM QSE-CI-AP-D NodeTM The QSE-CI-AP-D is a programming interface designed to be used with NodeTM units. It is compatible with the entire NodeTM product family (models starting with QSN- and QSNE-),

More information

QuantumR Light Management Hub

QuantumR Light Management Hub Quantum 369375e 1 04.02.2015 QuantumR Light Management Hub The Quantum light management hub provides a centralized connection point for Lutron EcoSystem digital ballast modules, Lutron power panels, GRAFIK

More information

GRX-3000 Control Units

GRX-3000 Control Units PRESET DIMMING CTROLS GRX-000 Control Units GRX-000 Control Units DESCRIPTI Cover (shown open) Base Zone Provide pushbutton recall of four preset lighting scenes. Control virtually any light source. Provide

More information

HomeWorks Wired Signature Series Keypads

HomeWorks Wired Signature Series Keypads HomeWorks Wired Signature Series Keypads Indicator Lights Programmable buttons DESCRIPTI 048-027 1a 02.21.03 HomeWorks Signature Series keypads provide homeowners with a simple and elegant way to operate

More information

LCP128 Dimming & Switching System

LCP128 Dimming & Switching System Dimming & Switching System lcp230240-1 05.09.05 System Overview is a combination dimming and switching system that provides a complete lighting control solution. The system consists of panels and control

More information

HomeWorks B & O Keypads. Installation Instructions Please Read Before Installing. Overview. Important Notes

HomeWorks B & O Keypads. Installation Instructions Please Read Before Installing. Overview. Important Notes Installation Instructions Please Read Before Installing Overview The HWBO-8SE-IR, HWBO-4SE-IR, and HWBO-4SE-M are for use with HomeWorks systems. The keypad buttons are programmed using the HomeWorks Utility.

More information

QSNE-2DAL-D Energi Savr Node QSTM 20 V. DALI Loop 2. seetouch QS Wallstation Energi Savr Node QS. QS Control Link

QSNE-2DAL-D Energi Savr Node QSTM 20 V. DALI Loop 2. seetouch QS Wallstation Energi Savr Node QS. QS Control Link LUTRON R Node TM NE-2DAL-D Fixture Controller NE-2DAL-D 09.0.09 Node TM The Node is a DIN-rail mounted controller for -compliant Digital Addressable loads. It provides bus power and control for two independent

More information

Energi Savr NodeTM for 0 10 V Energi Savr NodeTM with Softswitch

Energi Savr NodeTM for 0 10 V Energi Savr NodeTM with Softswitch Energi Savr NodeTM for 0 0 V Energi Savr NodeTM with Softswitch The Energi Savr NodeTM (ESN) family is a group of modular products for the control of lighting, receptacles, and other loads. This document

More information

EcoSystem to 0 10 V- Interface

EcoSystem to 0 10 V- Interface to Interface to Interface 369537i 1 03.22.19 The to Interface provides a control gateway from an link to a compatible lighting device, typically an ED driver. It allows for individual addressing of the

More information

HomeWorks QS Processor

HomeWorks QS Processor product specifications 369376d 06.03.15 The processor provides control and communication to system components. The Ethernet links allow communication to the software, integration with third party systems

More information

QSWS2-1BN- - QSWS2-1BI- - 1-Button Wallstation

QSWS2-1BN- - QSWS2-1BI- - 1-Button Wallstation QSWS-BN- - QSWS-BI- - -Button Wallstation Color and Codes LED 69489b 08.4.5 Offers toggle functionality for any combination of zone(s) in the system. Backlit buttons with optional engraving make it easy

More information

CONTROL PROTOCOL Motorized Projection Screens

CONTROL PROTOCOL Motorized Projection Screens CONTROL PROTOCOL Motorized Projection Screens Table of Contents Overview... 3 Control Wiring Diagram... 3 IR Control... 4 Remote Button IR Hex Commands... 4 12 Volt DC Trigger... 5 Contact Closure and

More information

QuantumR Light Management Hub (QP2)

QuantumR Light Management Hub (QP2) Quantum 369375f 1 11.05.15 QuantumR Hub (QP2) The Quantum light management hub provides a centralized connection point for Lutron EcoSystem digital ballast modules, Lutron power panels, and QS devices

More information

Rev Cutler-Hammer Smart Breaker Panel Control Manual

Rev Cutler-Hammer Smart Breaker Panel Control Manual 026-70 Rev 0 6-0-03 Cutler-Hammer Smart Breaker Panel Control Manual 640 Airport Road, Suite 04 Kennesaw, GA 3044 Phone: (770) 425-2724 Fax: (770) 425-939 ALL RIGHTS RESERVED. The information contained

More information

HomeWorks Wired seetouch Keypads (Domestic Models)

HomeWorks Wired seetouch Keypads (Domestic Models) HomeWorks Wired seetouch Keypads (Domestic Models) Programmable buttons Status LEDs ST-B-NI-WH SK-B-I SK-SIR-I DESCRIPTI 08-0 a.0.0 HomeWorks keypads, available in many styles, colors, and finishes, provide

More information

H704-42(H)(E), H704-42/1(H)(E)

H704-42(H)(E), H704-42/1(H)(E) POWER MONITORING INSTALLATION GUIDE H704-42(H)(E), H704-42/1(H)(E) Branch Current Monitor DANGER NOTICE Installer's Specifications General: Operating Temp. Range 0 to 60 C (32 to 140 F) (

More information

EA500. Installation Instructions Transponder

EA500. Installation Instructions Transponder EA500 EN Installation Instructions Transponder EA500 Installation Instructions 1.0 Overview EN 2 1.0 Overview The EA500 Transponder is the Security Escort module that provides communications between the

More information

HomeWorks QS Wired ArchitraveTM Keypads

HomeWorks QS Wired ArchitraveTM Keypads HomeWorks QS Wired ArchitraveTM keypads provide homeowners with a simple and elegant way to operate lights, shades /draperies, motorized screens, thermostats, and many other devices. Replacement faceplates

More information

Weight ounces Panel Fasteners... Four holes to accept four 16x32 machine screws NEMA Rating... NEMA 1

Weight ounces Panel Fasteners... Four holes to accept four 16x32 machine screws NEMA Rating... NEMA 1 8 Panel Specifications: In this section, you will be given all of the information you need to install the panel. Before actually installing the OP-9001 panel, it may be helpful to examine the specifications

More information

GRAFIK Eye 3000 Series Control Unit

GRAFIK Eye 3000 Series Control Unit GAFIK Eye 000 Series 000-0.9.07 GAFIK Eye 000 Series Control Unit Cover (shown open) Description Provides pushbutton recall of four preset lighting scenes, plus Off. Allows setup of lighting scenes using

More information

8S RS232/422/485 Combo to USB2.0 Module Box Installation Guide

8S RS232/422/485 Combo to USB2.0 Module Box Installation Guide Installation Guide Congratulation on your purchasing this high performance 8-port RS232/422/485 Combo to USB2.0 Module Box. The product includes a metal module box and a USB cable. Each box has an upstream

More information

Product Data Sheet. BMS/Graphics Interface. Features

Product Data Sheet. BMS/Graphics Interface. Features BMS/Graphics Interface Product Data Sheet Features The Mxp-010 interface allows BMS systems and graphics PCs to be integrated with the Mx- 4000 series of Fire Control Panels and Remote Terminals. The interface

More information

Wiring Section 3-3. NQ-Series communication ports support various types of (serial) communication.

Wiring Section 3-3. NQ-Series communication ports support various types of (serial) communication. 3-3 Wiring NQ-Series models have, besides one power connector, a number of communication ports. Please refer to Table 2.2: Common specifications for NQ-Series and Table 2.3: Specifications per NQ-Series

More information

HomeWorks QS GRAFIK T QS Slider

HomeWorks QS GRAFIK T QS Slider The HomeWorks QS GRAFIK T QS Slider provides a simple and elegant way to control lights and other 3rd party equipment as part of a lighting control system. The GRAFIK T QS Slider operates much like other

More information

Energi Savr Node with DALI for Quantum

Energi Savr Node with DALI for Quantum Energi Savr Node Digital Fixture Controller - CPN6916 Energi Savr Node with for Quantum 369794c 1 08.25.17 The Energi Savr Node family is a group of intelligent, modular products for the control of lighting

More information

Installation Instructions

Installation Instructions H Installation Instructions Danger - Locate and lock supply breaker in the OFF position before installing processor assembly. 1. Install processor in the enclosure: The HomeWorks 8 Series is attached to

More information

10-Output Configurable Smart Panel

10-Output Configurable Smart Panel 10-Output The 10-Output simplifies wiring and organizes installations with multiple Sivoia QS window treatments and other system devices and interfaces. 085593a 1 11.02.17 WIN-PS-5CC-R The 10-Output is

More information

seetouchtm B&O Keypads 15 V 65 ma NEC Class 2; IEC PELV

seetouchtm B&O Keypads 15 V 65 ma NEC Class 2; IEC PELV seetouchtm B&O Keypads 15 V 65 ma NEC Class 2; IEC PELV STBO-4SN STBO-4SI STBO-4SIRN STBO-4SIRI Overview The STBO-4SIRN, -4SIRI, -4SI and -4SN are for use with HomeWorks systems. The keypad buttons are

More information

MODEL: R1M-P4. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

MODEL: R1M-P4. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.) PC Recorders Series PC RECORDER (4 totalized counter inputs, 8 contact inputs and outputs) Functions & Features Industrial recorder on PC Totalized counter inputs Counts stored in E 2 PROM Easy system

More information

F1000 User's Manual. (Version: V1.01)

F1000 User's Manual. (Version: V1.01) (Version: V1.01) Contents Chapter 1 Overview... 2 Chapter 2 Installation... 3 2.1 Installation guide... 3 2.1.1 Installation position... 3 2.1.2 NEMA4 standard installation... 3 2.1.3 Environment precautions...

More information

TRP-C06H User s Manual

TRP-C06H User s Manual TRP-C06H User s Manual 2-Port RS-232 to RS-422/485 Isolated Converter Printed Feb.2007 Rev 1.1 Trycom Technology Co., Ltd 1F, No.2-11, Sihu street, Hinge Township, Taipei, Taiwan ROC Tel: 886-2-86781191,

More information

PLEASE READ INSTRUCTIONS CAREFULLY BEFORE INSTALLATION!

PLEASE READ INSTRUCTIONS CAREFULLY BEFORE INSTALLATION! TUC2 / TUCH2 Model Series Installation Instructions PLEASE READ INSTRUCTIONS CAREFULLY BEFORE INSTALLATION! APPLICATION The TUC2 provides temperature space monitoring with a backlit LCD. The TUCH2 provides

More information

CS XL XM. EcoSystem Bus Supply

CS XL XM. EcoSystem Bus Supply EcoSystem An EcoSystem lighting network containing more than one ballast, module, or driver requires an EcoSystem. This supply powers one or two independent EcoSystem buses with up to 64 ballasts or ballast

More information

Wallstation Installation Guide Please Read Low-Voltage PELV (Class 2: USA)

Wallstation Installation Guide Please Read Low-Voltage PELV (Class 2: USA) Wallstation Installation Guide Please Read Low-Voltage PELV (Class 2: USA) 24 V 30 ma QSWS2-1B QSWS2-2B QSWS2-3B QSWS2-5B QSWS2-7B QSWS2-2BRL QSWS2-3BRL QSWS2-5BRL QSWS2-2BRLIR QSWS2-3BRLIR QSWS2-5BRLIR

More information

MODEL: R1M-D1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

MODEL: R1M-D1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.) PC Recorders R1M Series PC RECORDER (contact output, 32 points) Functions & Features Industrial recorder on PC 32-point open collector outputs Easy system expansion via Modbus RTU Recorded data exportable

More information

Installing the Panel. Installing the Panel

Installing the Panel. Installing the Panel 7 In this section you will be given all of the information you need to install the panel. Before actually installing the OP- panel, it may be helpful to examine the specifications and make sure that the

More information

Industrial Media Converters

Industrial Media Converters Wireless AP Industrial s Introduction & Features Fiber s Ethernet s Serial s s Distance Extension With Higher Immunity Introduction The media converters have incorporated SUNIX advanced technologies such

More information

Introduction. General Ratings

Introduction. General Ratings Introduction Storage temperature Operating temperature Humidity Weight Dimensions Screw terminal wire gauge Supply voltage Supply currents Maximum baud rate Unit Mounting Housing o -20 to +70 C o Allows

More information

MODEL: R1M-A1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

MODEL: R1M-A1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.) PC Recorders R1M Series PC RECORDER (contact input, 32 points) Functions & Features Industrial recorder on PC 32-point dry contact inputs Easy system expansion via Modbus RTU Recorded data exportable to

More information

FCS AVI INTERFACE COMMANDS

FCS AVI INTERFACE COMMANDS Interface s FCS AVI INTERFACE COMMANDS 800.535.2465 acuitycontrols.com WARNING TO AVOID THE RISK OF FIRE AND SHOCK, DOORS MUST REMAIN CLOSED AT ALL TIMES Fresco 201-00075-001 FCS AVI 302-00151-002 Page

More information

RS485 Modbus adapter for RVT Touchscreen User guide

RS485 Modbus adapter for RVT Touchscreen User guide RS485 Modbus adapter for RVT Touchscreen User guide Table of contents 1 Introduction... 3 2 Overview... 3 2.1 Introduction to Modbus... 3 2.2 Modbus adapter mounting... 3 2.3 Modbus adapter wiring... 4

More information

EX KVIS RS232/422/485 3-in-1 Serial to USB Adapter (w/ 4KV Isolation, 15KV ESD Surge Protection)

EX KVIS RS232/422/485 3-in-1 Serial to USB Adapter (w/ 4KV Isolation, 15KV ESD Surge Protection) EX-1331-4KVIS RS232/422/485 3-in-1 Serial to USB Adapter (w/ 4KV Isolation, 15KV ESD Surge Protection) 1. Introduction Thank you for purchasing this RS232/422/485 3-in-1 Serial to USB Adapter. It is an

More information

Connecting a Cisco Input Module

Connecting a Cisco Input Module CHAPTER 4 Overview The optional Cisco Input Module (Figure 4-1) is attached to a Cisco Physical Access Gateway or Cisco Reader Module to provide additional connections for up to ten input devices. Each

More information

Energi Savr Node for DALI QSNE-2DAL-D DALI Fixture Controller V. Photo

Energi Savr Node for DALI QSNE-2DAL-D DALI Fixture Controller V. Photo UTRO R UTRO R ode for E-2DA-D Fixture Controller ode for The ode unit is a DI-rail mounted controller for -compliant digital addressable loads. It provides bus power and control for two independent buses

More information

LUTRON. Wallstations. Page. SPECIFICATION SUBMITTAL Model Numbers: Job Name: Job Number:

LUTRON. Wallstations. Page. SPECIFICATION SUBMITTAL Model Numbers: Job Name: Job Number: olor and Engraving odes SO-7N- - SO-7I- - 7-utton Wallstation LEDs Engraving so-7b 5..06 Description Used to select scenes. eceives up to two contact closure inputs via a connector on the back of the Wallstation.

More information

Wallbox Power Module. 4/8 Series Remote Dimming Controls Grafik Eye /WPM Link N/A INTRODUCTION SPECIFICATION & DESIGN FRONT ROOM BACK ROOM APPENDIX

Wallbox Power Module. 4/8 Series Remote Dimming Controls Grafik Eye /WPM Link N/A INTRODUCTION SPECIFICATION & DESIGN FRONT ROOM BACK ROOM APPENDIX Wallbox Power Module 4/8 Series Remote Dimming Controls Grafik Eye /WPM Link N/A W a l l b o x P o w e r M o d u l e (hwi-wpm-6d-120) HomeWorks Wallbox Power Modules (WPM) control six independent zones

More information

PXL-250 Tiger Controller

PXL-250 Tiger Controller PXL-0 Tiger Controller This quick start guide is made up of specification sheets, a DO/DON T list, basic installation drawings, first time power-on instructions, and short descriptions of key terms and

More information

DATA CONNECT ENTERPRISE

DATA CONNECT ENTERPRISE DATA CONNECT ENTERPRISE User s Manual IG202T and IGV23 Modem Document Number 520-01005-001 Rev. A DATA CONNECT Contents Contents... iii Figures... iv Chapter 1 Introduction... 5 Features...6 Applications...7

More information

HomeWorksR QS Dynamic Keypads

HomeWorksR QS Dynamic Keypads provide the functionality of multiple LutronR keypads in an easy-to-navigate, intuitive arrangement. help reduce wall clutter by combining control of several functions into a convenient, single point of

More information

4.7 Expansion Module MAC00-FS1/FS4

4.7 Expansion Module MAC00-FS1/FS4 MAC00-FS4 With M12 connectors MAC00-FS1 With D sub connectors TT1068GB 4.7.1 High speed serial RS485 module MAC00-FS1 and FS4 Introduction The MAC00-FS1 and FS4 are used for high speed RS485 communication

More information

4.8 Expansion Module MAC00-FS1/FS4

4.8 Expansion Module MAC00-FS1/FS4 .8 Expansion Module MAC00-FS/FS MAC00-FS With M connectors MAC00-FS With D sub connectors TT08GB.8. High speed serial RS8 module MAC00-FS and FS Introduction The MAC00-FS and FS are used for high speed

More information

High Power over Ethernet Midspans PD Port Model PD Port Model

High Power over Ethernet Midspans PD Port Model PD Port Model Data and Power on a Single Line High Power over Ethernet Midspans PD-8006-6 Port Model PD-8012-12 Port Model User Guide Notice The information contained herein is believed to be accurate and reliable at

More information

Back Room Equipment INTRODUCTION SPECIFICATION & DESIGN FRONT ROOM BACK ROOM APPENDIX

Back Room Equipment INTRODUCTION SPECIFICATION & DESIGN FRONT ROOM BACK ROOM APPENDIX Back Room Equipment http://resi.lutron.com Technical Support: product@lutron.com 89 P5 Processors HomeWorks processors comprise the major communication hub of a HomeWorks system. Each processor has communication

More information

Remote I/O Scanner. Catalog Number 1747-SN. Installation Instructions. Publication

Remote I/O Scanner. Catalog Number 1747-SN. Installation Instructions. Publication Remote I/O Scanner Catalog Number 1747-SN Installation Instructions 2 Remote I/O Scanner Important User Information Because of the variety of uses for the products described in this publication, those

More information

MODEL DRIVER Ic Ip VDC

MODEL DRIVER Ic Ip VDC Provides Mounting & Connections for Stepnet Module CANopen Stepping Driver FEATURES Develop & Debug Stepnet projects then transfer design to OEM pc board. MODEL DRIVER Ic Ip VDC -075-01 STM-075-07 5 7

More information

BioPointe Reader Installation Guide

BioPointe Reader Installation Guide BioPointe Reader Installation Guide What s in this Guide Installation Steps 1 Key Parts of the BioPointe Reader 2 Cabling Requirements 3 Power Connection 3 PXL-500W Wiegand Controller Connection 3 Serial

More information

TRP-C08. USB to RS232/422/485 Isolated Converter. User s Manual. Printed Sep.2014 Rev 1.4

TRP-C08. USB to RS232/422/485 Isolated Converter. User s Manual. Printed Sep.2014 Rev 1.4 TRP-C08 USB to RS232/422/485 Isolated Converter User s Manual Printed Sep.2014 Rev 1.4 Trycom Technology Co.,Ltd No.35, Zhongxing Rd., Guishan Township, Taoyuan County 333, Taiwan. Tel : 886-3-350-3351

More information

ADAM-4510 RS-422/RS-485 Repeater ADAM-4510S Isolated RS-422/485 Repeater ADAM-4520 Isolated RS-422/485 Converter Startup Manual

ADAM-4510 RS-422/RS-485 Repeater ADAM-4510S Isolated RS-422/485 Repeater ADAM-4520 Isolated RS-422/485 Converter Startup Manual ADAM-510 RS-/RS-85 Repeater ADAM-510S Isolated RS-/85 Repeater ADAM-50 Isolated RS-/85 Converter Startup Manual Packing List Before you begin installing your module, please make sure that the following

More information

GE Industrial Solutions. DET-756 Installation Instructions ASPMETER Panelboard Monitoring System

GE Industrial Solutions. DET-756 Installation Instructions ASPMETER Panelboard Monitoring System GE Industrial Solutions DET-756 Installation Instructions SPMETER Panelboard Monitoring System Safety If SPMETER products are used in installations with circuits higher than the product ratings, the circuits

More information

*Recommendations are subject to change. Consult your Lumenetix representative for the most updated list. Eco Loop 1. Eco Loop 2. Wallstation.

*Recommendations are subject to change. Consult your Lumenetix representative for the most updated list. Eco Loop 1. Eco Loop 2. Wallstation. ECOSYSTEM PROTOCOL 1.1 Lutron EcoSystem Protocol EcoSystem technology is a control method for LEDs that provides addressing of individual fixtures and status feedback. This makes it easy to digitally assign

More information

EP-ELVCTL Elevator Control (NION-16C48M)

EP-ELVCTL Elevator Control (NION-16C48M) EP-ELVCTL Elevator Control (NION-16C48M) Product Installation Document This document covers the procedures and specifications for installing the above listed unit and when appropriate, information regarding

More information

HomeWorks QS Wired seetouch Designer Keypads

HomeWorks QS Wired seetouch Designer Keypads product specifications 369354c 04.09.14 HomeWorks QS seetouch keypads provide homeowners with a simple and elegant way to operate lights, shades / draperies, motorized screens, thermostats, and many other

More information

DWYER INSTRUMENTS, INC. Series AVUL Air Velocity Transmitter. Specifications - Installation and Operating Instructions.

DWYER INSTRUMENTS, INC. Series AVUL Air Velocity Transmitter. Specifications - Installation and Operating Instructions. Series AVUL Air Velocity Transmitter Specifications - Installation and Operating Instructions Bulletin P-AVUL 3-49/64 [95.71] 2-43/64 [67.92] 1/2 NPS 3-3/16 [80.81] 1-19/32 [40.59] 31/32 24.58 3-33/64

More information

I-7570 Serial To HART Converter

I-7570 Serial To HART Converter I-7570 Serial To HART Converter User s Manual Warranty All products manufactured by ICP DAS are under warranty regarding defective materials for a period of one year from the date of delivery to the original

More information

HomeWorksR QS 1-Link Processor

HomeWorksR QS 1-Link Processor product specifications 36905a 2.3.6 HomeWorksR QS -Link rocessor The HomeWorksR QS processor provides control and communication to HomeWorksR QS system components. The Ethernet link allows communication

More information

User Manual. cmt-svr Startup Guide

User Manual. cmt-svr Startup Guide User Manual cmt-svr Startup Guide Table of Contents Chapter 1 Overview... 1 1.1 Specification... 1 1.2 Dimensions... 2 1.3 Connector pin designations... 3 1.4 USB host port and SD card slot... 3 1.5 Ethernet

More information

VirtualSCADA VSU-485G USB to RS422/485 Isolated Converter User Manual

VirtualSCADA VSU-485G USB to RS422/485 Isolated Converter User Manual VirtualSCADA USB to RS422/485 Isolated Converter User Manual Revision 1.01.00 Page 1 (15) Table of contents Warranty and support... 3 Product return... 3 1 About the VirtualSCADA USB to RS422/485 Converter...

More information

C-DIAS Serial Interface CSI 021

C-DIAS Serial Interface CSI 021 C-DIAS SERIAL INTERFACE CSI 021 C-DIAS Serial Interface CSI 021 The CSI 021 makes it possible to communicate via 2 independent UART's. 2 x RS232/485/422 outputs are available. These outputs are switchable

More information

Product Manual. QD2040a Ubiquity Site Gateway. Contents. Description. Features. Material List

Product Manual. QD2040a Ubiquity Site Gateway. Contents. Description. Features. Material List Product Manual QD2040a Ubiquity Site Gateway Description The QD2040a Ubiquity Site Gateway connects the site controller network with the central Ubiquity server. Features Site gateway to Ubiquity: enables

More information

PCIEMODBOX232 RS232 to PCI Module Box Introduction

PCIEMODBOX232 RS232 to PCI Module Box Introduction PCIEMODBOX232 RS232 to PCI Module Box Introduction This high performance PCI (or PCIe) RS232/422/485 Combo Expansion Module product includes an expansion module box, a PCI (or PCIe) Host Adapter and a

More information

Connecting a Cisco Output Module

Connecting a Cisco Output Module CHAPTER 5 Overview The optional Cisco Output Module (Figure 5-1) is attached to a Cisco Physical Access Gateway or Cisco Reader Module to provide additional connections for up to 8 outputs, each of which

More information

RS-232 to RS-422/485 Converter with 3KV Isolation Protection

RS-232 to RS-422/485 Converter with 3KV Isolation Protection RS-232 to RS-422/485 Converter with 3KV Isolation Protection (ID-SC0E11-S1) User s Manual 04-0779A - 1 - Introduction The serial converter converts RS 232 signals to RS 422 or RS 485 and extends the communication

More information

Installation & Operation Guide

Installation & Operation Guide Installation & Operation Guide Direct Digital VAV Controllers KMD-7001/7051 - VAV Terminal Units KMD-7002/7052 - Dual Duct VAV Units KMD-7003/7053 - Fan Induction Units 907-019-01C 1 Introduction This

More information

Energi Savr NodeTM QSN-2ECO-PS120 EcoSystem with Shades ESN a

Energi Savr NodeTM QSN-2ECO-PS120 EcoSystem with Shades ESN a 085-255a 1 08.26.10 with shades Energi Savr Node The with Shades Energi Savr Node (ESN) (QSN 2ECO-PS120) is an integrated lights and shades panel. This document describes the with Shades ESN, which can

More information

205 CPU NETWORK ADAPTER F2-UNICON

205 CPU NETWORK ADAPTER F2-UNICON 205 CPU NEWORK ADAPER F2-UNICON Network Adapter he F2-UNICON Network Adapter is used to place Automationdirect.com DL205 CPUs (except D2-230 and D2-250) on a RS-422 or RS-485 multi-drop network. he Network

More information

FLEX Ex Spring Clamp Terminal Base

FLEX Ex Spring Clamp Terminal Base Installation Instructions FLEX Ex Spring Clamp Terminal Base (Cat. No. 1797-TB3S) 1 10 11 4 Only remove this cover plug if connecting another terminal base unit. 3 5 6 12 2 7 8 9 41253 Component Identification

More information

UC-2000 Installation Manual Unicorn Computers Technology Limited

UC-2000 Installation Manual Unicorn Computers Technology Limited UC2000 Installation Manual Copyright 2003. All rights reserved. Table of Contents Specifications 2 Enclosure for the UC2000 Controller 3 Unicorn Access Control System Configuration 4 UC2000 Controller

More information

RMB-3 Peripheral Unit. Installation Guide INSTALLATION GUIDE WESTELL.COM. Westell Technologies Part # Rev. A

RMB-3 Peripheral Unit. Installation Guide INSTALLATION GUIDE WESTELL.COM. Westell Technologies Part # Rev. A RMB-3 Peripheral Unit Installation Guide INSTALLATION GUIDE Westell Technologies Part # 030-300812 Rev. A Copyright 2017 by Westell Technologies. All Rights Reserved. The material discussed in this publication

More information

MODEL: R1M-GH. PC Recorders R1M Series

MODEL: R1M-GH. PC Recorders R1M Series PC Recorders Series PC RECORDER (thermocouple or DC input, 16 points) Functions & Features Industrial recorder on PC 16-point thermocouple or DC inputs Easy system expansion via Modbus RTU Recorded data

More information