D-R300 / D-R320 / D-R 800 DATASHEET

Size: px
Start display at page:

Download "D-R300 / D-R320 / D-R 800 DATASHEET"

Transcription

1 D-R300 / D-R320 / D-R 800 DATASHEET JUNHO 2013

2 Measuring principle The D-R 300 / D-R meters operate according to the scattered light method. The modulated light from a Halogen lamp illuminates the dust particles in the exhaust duct. The scattered light reflected from these particles is measured and assessed. Measuring device for smoke spot number / dust concentration D-R 300: Extremely sensitive device for measuring smoke spot number. D-R : Especially sensitive measuring device for the smallest concentration of dust, in particular in waste incineration plants. In-situ measurement directly in the flow Automatic system tests and correction of measured values Self-calibration in 4-h cycle Optics and electronics in a hermetically sealed unit - no smoke gas can enter device Maintenance-friendly, thanks to optimal purge air conduction in front of the heated optical end plates Direct access to all parameters via the operator display Automatic measuring range selection in accordance with 17. BImSchV. in relation 1:3:9*. Smoke spot number measurement in furnaces designed for light fuel oil Fine dust measurements in processes Waste incineration Filter monitoring and emission-value measuring in waste incineration and power plants*. Approvals Suitability-tested by the TÜV Cologne, test report 936/ Suitability-tested by the TÜV Cologne, test report 936/801004* Itemized in the list of suitable measuring devices for continuous emission measuring MCERTS. *D-R Measuring head Mounting flange Control and display unit light trap(s) Purge air unit. Automatic measuring range selection for dust measurement in accordance with 17. BImSchV (D-R ) Weather protection covers Quick-closing shutter to protect measuring device in the event of failure of the purge air supply Halar flange coating. measurements measuring ranges measuring principle pressure smoke spot number (D-R 300) dust concentration (D-R ) D-R 300: smoke spot number 1 3 (5) D-R : dust concentration 0 1 mg/m mg/m 3 1), optional mg/m 3 with range switching Specifications D-R 300 Measuring range: smoke spot number 0-3. Limit value II can be set as delayed disconnected contact Calibration: VDI 2066, page 8. D-R Minimum measuring range 0-1 mg/m 3 dust concentration. Other measuring ranges up to 300 mg/m 3 can be set (optional automatic switching of measuring ranges 1:3:9) Calibration: VDI 2066, page 7. light trap 2nd light trap (D-R 300 only) detection limit reference point drift quick-closing shutter (optional) <1% measuring range purge air unit control and display unit <0.2% of measuring range/month back scattering zero point drift <0.2% of measuring range/month above dew point up to 320 C, optional up to 600 C, depending on application -50 up to +20 hpa supply voltage duct diameter 0.3 to 4 m 18 kg 115 / 230 VAC, 50 / 60 Hz, 50 VA 565 x 310 x 200 mm -20 up to +50 C remarks 1) after gravimetric calibration protection IP65 purge air supply measuring outputs digital outputs digital inputs 2 x 0/4 20 ma/500 Ohm, optional measuring range switching 3 relay outputs, permissable load 48 V / 0.5 A 1 potential free input purge air quantity approx. 80 m 3 /h supply voltage 115 / 230 VAC, 50 / 60 Hz, 0.37 / 0.43 kw 350 x 550 x 500 mm 12 kg accuracy <1% of measuring range protection IP54

3 D-R 320 The new scattered light dust monitor D-R 320 High-sensitivity measurement even at the lowest concentrations of dust Stray light measurement redefined Universal mounting: DN 100 PN 6 DIN flange The light of a red laser diode (eye safe) illuminates the dust particles in the measuring volume of the duct. The light is scattered by the particles and also generates background light in the stack. Scattered light plus background light are received in one half of the integrated dual detector. At the same time the other half of the detector receives only the background light from the same area of the stack, without the stray light portion. After subtraction of the background light the pure amount of scattered light is available. Since both parts of the integrated double detector share the same optics unit, no adjustment of the beam paths is necessary. The D-R 320 is ready for operation directly after mounting and can easily be operated at another measurement point. Universal mounting: ANSI lbs standard flange The new DURAG dust monitor D-R 320 is based on the backscattering principle and is ideally suited for monitoring smallest to medium dust concentrations. The measurement takes place continuously in the stream. Naturally the D-R 320 is compliant with the high requirements of the new European standards and therefore suitable for measurements according to official regulations. Startup without adjustment due to unique optical design The D-R 320 does not require a light trap. The background light in the stack is detected by means of a special optical system with dual detector and automatically compensated without the need of any manual adjustment. Advantage of this new design is the quick and uncomplicated installation, completely without adjustment at site. So the D-R 320 is ready for operation directly after installation and flexible for different applications. Even after a conversion to a different measurement point the device is operational immediately again. Single-sided installation on standard flanges without light trap The D-R 320 allows single sided installation at the stack and requires just a small wall opening. It can be mounted in any orientation via a rotatable connection on existing DN 100 PN 6 or ANSI lbs standard flanges. This reduces time and costs for installation. Universal mounting:rotatable, for any flange orientation Long life due to integrated purge air monitoring and control The D-R 320 is continuously purged and therefore the optical system is not in contact with the exhaust gas. The integrated purge air control ensures the optimum amount of purge air. This ensures a long life and long maintenance intervals. A purge air failure is immediately indicated by the device. The maintenance of the device is minimal. Convenient operation, readings anywhere accessible The operation of the D-R 320 is comfortable and extremely flexible. Different operating options are available: local via USB interface by means of the external operation unit D ISC 100 remote access with RS-485 interface via MODBUS RTU / MODBUS TCP protocol (acc. to VDI ) Automatic control functions ensure reliable measuring values Reliability has the highest priority when measuring emissions. For that reason the D-R 320 automatically performs zero and span check as well as contamination check in regular intervals and on demand. The device features an automatic contamination correction. Need for maintenance is immediately indicated by the electronics. Measuring head Mounting flange Universal control unit D-ISC 100 Weather protection covers Fully integrated failsafe shutter as protection for the measuring device in case of a purge air failure. With the integrated fail safe shutter the D R 320 is optimally protected for reliable use even under overpressure conditions. Universal Operation Unit D-ISC 100 The universal operation unit D-ISC 100 allows for the connection of up to 8 DURAG measuring heads and enables the combination of dust and flow measurements. The D-ISC 100 offers convenient operation and parameterization of the connected devices. The display provides an immediate overview of the current measurements and the status of the devices. Connection of up to 8 s Local operation with keypad, through USB port or remotely through RS-485 interface. Modular design, many extension modules available Supply unit with integrated purge air supply Continuous measurement of dust concentration Easy installation on standard flanges Easy startup without adjustment Automatic background light compensation, no light trap Convenient operation, remote access possible Automatic control functions Integrated purge air monitoring and control Long service intervals Certified acc. to EN Integrated fail safe shutter as an option Data transfer via Modbus compliant with VDI Continuous emission monitoring, e.g.: on incineration plants generally on plants according to IED 2010/75/EU on plants according to 2001/80/EC LCPD on waste, hazardous waste and sewage sludge incineration plants on cement manufacturing plants on power plants with gas, oil, coal or cofiring on plants for the incineration of biomass Monitoring of: ventilation units filter units Technical Data measurements dust concentration measuring range min: 0 5 mg/m3, max: mg/m3 measuring principle back scattering C pressure hpa, optional higher duct diameter > 0.7 m -40 up to +60 C protection IP 65, Ex optional measuring outputs 0 / 4 20 ma / 400 Ohm, Modbus RTU bi-directional digital outputs 2 relay outputs, permissible load 60 VDC / 30 VAC / 0.5 A supply voltage 24 VDC, 0.5 A 200 x 190 x 260/410 mm 15 kg supply unit purge air supply integrated blower supply unit 115/230 VAC, 50/60 Hz, 0.37/0.43 kw 480 x 450 x 320 mm 12 kg protection IP 65

4 Dust monitor Innovative measuring device with laser technology to monitor small to medium dust emission according to the new European regulations. Integrated display: Measuring value, threshold value, parameter in probe In-situ measuring procedure with continuous measurement High sensitivity Easy installation on one side of the duct Can also be deployed in thick-walled stone/ insulated channels Long lifetime, as there are no moving parts inside the duct Hermetically sealed electronic housing against exhaust gas Parameterisation and operation with keyboard plus easily readable display directly on device or via bus interface Automatic function test with soiling correction Two analog outputs with adjustable measuring ranges Automatic switching of measuring ranges according to 17. BImSchV. Power stations Cement plants, the metallurgy and wood industries, chemical industry etc. Waste incineration plants Monitoring of dust filter plants. Measuring principle The D-R 800 device works according to the principle of forward scattering. The concentrated and modulated light of a laser diode penetrates the measuring volume. The forward-scattered light largely reflected from dust particles is measured and assessed. measuring lance Measuring lance Supply unit with integrated purge air supply Mounting flange 130 / 240 / 500 mm. Weather protection cover Temperature compensation through additional analog input. evaluation unit supply unit with integrated purge air supply RS 485 and analog current output Approvals Suitability-tested by the TÜV Cologne, test report 936/ /A Itemized in the list of suitable measuring devices for continuous emission measuring MCERTS pending. measurements dust concentration accuracy <1% of measuring range limit measuring ranges 0 10 mg/m mg/m 3 1) detection limit <0.5% measuring range measuring principle forward scattering above dew point up to 220 C reference point drift <0.7% of measuring range/month zero point drift <0.15 % of measuring range/ month pressure -50 up to +10 hpa supply voltage VAC, Hz, 50 VA pending duct diameter probe length (from flange) protection m 400 / 800 mm measuring lance: 160 x 160 x 600 / 1000 mm supply unit: 380 x 300 x 210 mm measuring lance: 7 kg supply unit: 13 kg -20 up to +50 C purge air supply integrated into supply unit IP65 measuring outputs digital outputs digital inputs 2 x 0 / 4 20 ma / 500 Ohm, Modbus RTU (RS485) 4 relay outputs, programmable, permissable load 24 V / 25 VA 2 potential free inputs, programmable remarks 1) after gravimetric calibration

5 Contactos/Contacts: Comercial/Commercial: Luís Ferreira da Costa Tel: (+351) Fax: (+351) Assistência/Service: Joaquim Picante Tel: (+351) Horas: (+351) Note: DURAG, Inc., the owner of this document, reserves the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. DURAG, Inc. does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. Copyright 2011 DURAG, Inc. All rights reserved

Online data sheet DUSTHUNTER SB100 SCATTERED LIGHT DUST MEASURING DEVICES

Online data sheet DUSTHUNTER SB100 SCATTERED LIGHT DUST MEASURING DEVICES Online data sheet DUSTHUNTER SB100 DUSTHUNTER SB100 A B C D E F H I J K L M N O P Q R S T 15267 14181 certified certified Ordering information Type DUSTHUNTER SB100 Part no. On request The exact device

More information

Product Overview. Emission Monitoring Ambient Monitoring Environmental and Process Data Management Systems

Product Overview. Emission Monitoring Ambient Monitoring Environmental and Process Data Management Systems Product Overview Emission Monitoring Ambient Monitoring Environmental and Process Data Management Systems Introduction Monitor selection 2 The DURAG GROUP develops and manufactures products in the field

More information

Online data sheet DUSTHUNTER SB30 SCATTERED LIGHT DUST MEASURING DEVICES

Online data sheet DUSTHUNTER SB30 SCATTERED LIGHT DUST MEASURING DEVICES Online data sheet DUSTHUNTER SB30 DUSTHUNTER SB30 A B C D E F H I J K L M N O P Q R S T Ordering information Type DUSTHUNTER SB30 Part no. On request The exact device specifications and performance data

More information

Online data sheet. FW101 Ex SCATTERED LIGHT DUST MEASURING DEVICES

Online data sheet. FW101 Ex SCATTERED LIGHT DUST MEASURING DEVICES Online data sheet A B C D E F H I J K L M N O P Q R S T Ordering information Type Part no. On request The exact device specifications and performance data of the product may deviate from the information

More information

CO, NO, NO 2, NO x, SO 2, CH 4, HCl, N 2 O, CO 2 & H 2 O

CO, NO, NO 2, NO x, SO 2, CH 4, HCl, N 2 O, CO 2 & H 2 O Product Data Sheet CODEL Continuous Emission Monitoring GCEM4000 Gas Analyser CO, NO, NO 2, NO x, SO 2, CH 4, HCl, N 2 O, CO 2 & H 2 O In-situ, low maintenance devices for continuous process and emissions

More information

Product Overview. Emission Monitoring Ambient Monitoring Environmental and Process Data Management Systems

Product Overview. Emission Monitoring Ambient Monitoring Environmental and Process Data Management Systems Product Overview Emission Monitoring Ambient Monitoring Environmental and Process Data Management Systems smart solutions for combustion and environment 2 The DURAG GROUP develops and manufactures products

More information

Product Overview Emission Monitoring Ambient Monitoring Environmental and Process Data Management Systems

Product Overview Emission Monitoring Ambient Monitoring Environmental and Process Data Management Systems Product Overview Emission Monitoring Ambient Monitoring Environmental and Process Data Management Systems smart solutions for combustion and environment Devices for emissions and immissions Measurement

More information

CO, NO, NO 2, NO x, SO 2, CH 4, HCl, CO 2 & H ² O. In-situ low cost, low maintenance devices for continuous process and emissions monitoring.

CO, NO, NO 2, NO x, SO 2, CH 4, HCl, CO 2 & H ² O. In-situ low cost, low maintenance devices for continuous process and emissions monitoring. Product Data Sheet Continuous Emission Monitoring GCEM 40 Series Gas Analyser CO, NO, NO 2, NO x, SO 2, CH 4, HCl, CO 2 & H ² O In-situ low cost, low maintenance devices for continuous process and emissions

More information

Continuous Flow Monitoring

Continuous Flow Monitoring Product Data Sheet CODEL Continuous Flow Monitoring VCEM5000/5100 Flue Gas Flow Monitor In-situ, low maintenance devices for continuous measurement of hot gas flow Non-contact infra-red sensing Continuous

More information

MCS 100 E. Compact IR Photometer for Stack Gas Monitoring

MCS 100 E. Compact IR Photometer for Stack Gas Monitoring P R O D U C T I N F O R M A T I O N MCS 100 E Compact IR Photometer for Stack Gas Monitoring Modern Emission Measuring Technology: Compact Stack Gas Monitoring The MCS 100 E is an extremely compact multi-component

More information

HYGROPHIL-F, Moisture Analyzer, Type , -11, -12, -13 series A

HYGROPHIL-F, Moisture Analyzer, Type , -11, -12, -13 series A HYGROPHIL-F, Moisture Analyzer, Type 5673-10, -11, -12, -13 series A Moisture Measurement in gases and liquids Combined moisture and temperature sensor Multiple channel analyzer, max. 3 sensors can be

More information

Digital Explosion-proof Intercom Stations DX/DXE 0x5 Series

Digital Explosion-proof Intercom Stations DX/DXE 0x5 Series Digital Explosion-proof Intercom Stations DX/DXE 0x5 Series Features and Functions For use in explosive (hazardous) areas of Ex zone 1 and 2 Equipment group and category Ex II 2G Temperature range of DX

More information

DMT345 and DMT346 Dewpoint Transmitters

DMT345 and DMT346 Dewpoint Transmitters DMT345 and DMT346 Dewpoint Transmitters for High Temperature Applications Features DMT345 measures humidity at temperatures up to 180 C (356 F) DMT346 measures humidity at temperatures up to 350 C (+662

More information

C-Flow Coriolis Mass Flow Meter

C-Flow Coriolis Mass Flow Meter Coriolis Mass Flow Meter Application and Features For fluids (e.g. PU components, paints) and gases of high density Suitable for aggressive and contaminated media Measurement of mass flow, density, temperature

More information

Vane wheel probe BFA25 for flow measurement of gases and liquids with integrated, configurable transducer UFA in Ex-d housing

Vane wheel probe BFA25 for flow measurement of gases and liquids with integrated, configurable transducer UFA in Ex-d housing Vane wheel probe BFA25 for flow measurement of gases and liquids with egrated, configurable transducer UFA in Ex-d housing Drawing 5 Vane wheel flow probe BFA25 (Dimensions see Page 3) Measurable variables

More information

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1 ) ATÜVRheinland':` Precisely Right. CERTIFICATE of Product Conformity (QAL1 ) Certificate No.: 0000054059 Evaluation system: D-EMS 2020 c/w remote emission data transmission module Manufacturer: Test Laboratory:

More information

Digital Outdoor Intercom Station DA/DAE 0x5 Series

Digital Outdoor Intercom Station DA/DAE 0x5 Series Digital Outdoor Intercom Station DA/DAE 0x5 Series Features and Functions Robust construction for use in harsh industrial environments Degree of protection IP66 Glass-fiber reinforced polyester Configurable

More information

PTU300 Combined Pressure, Humidity and Temperature Transmitter

PTU300 Combined Pressure, Humidity and Temperature Transmitter PTU300 Combined Pressure, Humidity and Temperature Transmitter For Demanding Applications Features Barometric pressure, humidity, and temperature measurement in one transmitter RS-232C serial interface

More information

Flow VA 500/

Flow VA 500/ VA 500/ 520 Verbrauch 79 What are the advantages of the flow measuring technology of CS Instruments? 1) 500 is mounted by means of a standard 1/2 ball valve. During mounting and dismounting the safety

More information

Endress Hauser CUM 740. Measuring Transmitter for Turbidity and Solids Content ISO The Power of Know How

Endress Hauser CUM 740. Measuring Transmitter for Turbidity and Solids Content ISO The Power of Know How Technical Information TI 232C/07/en 51504297 Measuring Transmitter for Turbidity and Solids Content The transmitter is used for optical solid matter content measurement in clear and turbid water and in

More information

MID approval no. DE-08-MI004-PTB004 Date of release

MID approval no. DE-08-MI004-PTB004 Date of release 1. Identification Energy and Flow Computer Flow rate and energy calculator for liquids, gases and water steam E-DB-1000-700-01 MID approval no. DE-08-MI004-PTB004 Date of release 04.01.08 2. Area of Application

More information

Level gauges Series LS Level indicator, switch and transmitter for liquids

Level gauges Series LS Level indicator, switch and transmitter for liquids Level gauges Series LS Level indicator, switch and transmitter for liquids Simple construction Resistant under extreme temperature and pressure conditions No risk of leakage Measuring range: from 150 mm

More information

EElectronic Devices and Systems. EK-87 Electronic Volume Corrector. This product is discontinued!

EElectronic Devices and Systems. EK-87 Electronic Volume Corrector. This product is discontinued! EElectronic Devices and Systems EK-87 Electronic Volume Corrector This product is discontinued! In brief EK-87 electronic volume corrector System volume corrector including integrated data storage device

More information

Output Signal. 22DTM-16 BACnet DC V, DC V. Electrical data Power Supply DC V, ±10%, 0.3 W

Output Signal. 22DTM-16 BACnet DC V, DC V. Electrical data Power Supply DC V, ±10%, 0.3 W Duct Sensor CO₂ / Humidity / Temperature Duct air quality sensor for combined detection of CO₂, relative humidity and temperature. Designed for control and monitoring applications. Type Overview Type Output

More information

DMT340 Series Dewpoint and Temperature Transmitters for Very Dry Conditions

DMT340 Series Dewpoint and Temperature Transmitters for Very Dry Conditions www.vaisala.com DMT340 Series Dewpoint and Temperature Transmitters for Very Dry Conditions The display shows measurement trends, real-time data, and measurement history. Features/Benefits Measures dew

More information

Series DMHF Heat Meter

Series DMHF Heat Meter Series DMHF Heat Meter The Series DMHF adopt the MultiPulse TM Technology, Digital Signal Processing Technology and Error Correction Technology, which are the state-of-the-art non-invasive flow measurement

More information

Flow. Order number VA 550. Order no. VA 570. Further accessories A_...M_

Flow. Order number VA 550. Order no. VA 570. Further accessories A_...M_ Order number VA 550 housing High-pressure rig for VA 550 recoended for mounting from 10 to 100 bar Order no. 0695 0550 A_...M_ 0530 1155 Order no. VA 570 Order no. 0695 0570 0695 0571 0695 0572 0695 0573

More information

Precision digital pressure gauge Model CPG1500

Precision digital pressure gauge Model CPG1500 Calibration technology Precision digital pressure gauge Model CPG1500 WIKA data sheet CT 10.51 for further approvals see page 4 Applications Oil and gas industry Maintenance and service facilities Calibration

More information

icountpd Online Particle Detector

icountpd Online Particle Detector Online Particle Detector The icountpd from Parker represents the most up-to-date technology in solid particle detection. The design dynamics, attention to detail, and small size of the permanently mounted,

More information

Output signal. 22DTM-16 BACnet DC V, DC V. Electrical data Power supply DC V, ±10%, 0.3 W

Output signal. 22DTM-16 BACnet DC V, DC V. Electrical data Power supply DC V, ±10%, 0.3 W Duct Sensor CO₂ / Humidity / Temperature For combined measurement of CO₂, relative humidity and temperature in the duct. Dual channel CO₂ technology. The measured values are output via BACnet. NEMA 4X

More information

Technical Information Promonitor NRF560

Technical Information Promonitor NRF560 TI00462G/08/EN/03.14 71264171 Products Solutions Services Technical Information For tank side monitor and control of Proservo NMS5 intelligent tank gauge Application is a monitoring unit for use with Proservo

More information

DTM Distributed Transmitter Monitor

DTM Distributed Transmitter Monitor Distributed Transmitter Monitor 96 Communication Module The 96 functions as an RS232 to RS485 convertor and / or enables (32) modules to be networked together via Modbus. Combined with the -CFG configuration

More information

MMT330 Series Moisture and Temperature Transmitters for Oil

MMT330 Series Moisture and Temperature Transmitters for Oil MMT330 Series Moisture and Temperature Transmitters for Oil Features Continuous online measurement of moisture in oil Ball-valve installation no need to shut down the process or drain the oil Proven Vaisala

More information

Compressed air quality meas. according to ISO 8573 Residual oil content - particles - moisture

Compressed air quality meas. according to ISO 8573 Residual oil content - particles - moisture Compressed air quality meas. according to ISO 8573 Residual oil content - particles - moisture Residual oil content measurement OIL-Check 400 For permanent and highly precise measurement of the vaporous

More information

Flamma BIOMASS COMBUSTION SYSTEM CONTROLLER. Preliminary Description V.1 Santi Moroño / Jose Caldelas / Juan R. Regueiro / 26/02/ :34

Flamma BIOMASS COMBUSTION SYSTEM CONTROLLER. Preliminary Description V.1 Santi Moroño / Jose Caldelas / Juan R. Regueiro / 26/02/ :34 Flamma BIOMASS COMBUSTION SYSTEM CONTROLLER Preliminary Description V.1 Santi Moroño / Jose Caldelas / Juan R. Regueiro 18-02-2013 / This document presents some preliminary ideas for the development of

More information

Dräger Polytron 8200 Stationary gas detector (CatEx)

Dräger Polytron 8200 Stationary gas detector (CatEx) Dräger Polytron 8200 Stationary gas detector (CatEx) Quick, reliable and cost-effective detection of combustible gases and vapours in the ambient air: the microprocessor-based transmitter is the result

More information

LiquiDens. SensoTech. Process density meter for liquids Product description

LiquiDens. SensoTech. Process density meter for liquids Product description SensoTech LiquiDens Process density meter for liquids Product description SensoTech GmbH, Steinfeldstraße 3, D-39179 Magdeburg-Barleben Tel +49 39203 961300, Fax +49 39203 961309, Internet www.sensotech.com

More information

Dräger Polytron IR. Dräger Polytron IR: Configurable gas detector for reliable detection of combustible gases and vapours.

Dräger Polytron IR. Dräger Polytron IR: Configurable gas detector for reliable detection of combustible gases and vapours. DETECTION PERSONAL PROTECTION DIVING TECHNOLOGY SYSTEM TECHNOLOGY SERVICES Dräger Polytron IR ST-3949-2004 The Dräger Polytron IR is an explosion proof infrared gas detector for continuous monitoring of

More information

Output signal active note. Output signal. temperature DC V, DC V DC V, DC V DC V

Output signal active note. Output signal. temperature DC V, DC V DC V, DC V DC V Duct Air Quality Sensor Duct air quality sensor for detection of CO₂ with 0 to10 V output. Optional integrated, humidity, VOC sensors and LCD display. Type Overview Type active CO₂ 22DC-11 22DC-110L 22DCK-11

More information

Unique Compressed Air Management System. GD Connect 12. The perfect fit

Unique Compressed Air Management System. GD Connect 12. The perfect fit Unique Compressed Air Management System GD Connect 12 The perfect fit State-of-the-art Technology Advanced Microprocessor Technology Safe and fast exchange of large amounts of data is ensured by large

More information

DUSTTRAK II AEROSOL MONITORS MODELS 8530, 8530EP AND 8532

DUSTTRAK II AEROSOL MONITORS MODELS 8530, 8530EP AND 8532 DUSTTRAK II AEROSOL MONITORS MODELS 8530, 8530EP AND 8532 DESKTOP OR HANDHELD UNITS FOR ANY ENVIRONMENT, ANY APPLICATION DustTrak II Aerosol Monitors are battery-operated, data-logging, light-scattering

More information

DUSTHUNTER SP100 Dust Concentration Monitor

DUSTHUNTER SP100 Dust Concentration Monitor Title Page DUSTHUNTER SP100 Dust Concentration Monitor MMMOPERATING INSTRUCTIONSMMMI Installation, Operation, Maintenance Described Product Product name: DUSTHUNTER SP100 Manufacturer SICK Engineering

More information

Series 255. Flow Averaging Transmitter TECHNICAL SPECIFICATIONS

Series 255. Flow Averaging Transmitter TECHNICAL SPECIFICATIONS TEHNIAL SPEIFIATIONS Flow Averaging Transmitter The Kurz Flow Averaging Transmitter is a versatile system transmitter designed for measuring flow rates in very large ducts that have non-uniform or unstable

More information

Output Signal. Temperature 22DTH-56M BACnet DC V, DC V. Electrical Data Power Supply DC V, ±10%, 0.7 W

Output Signal. Temperature 22DTH-56M BACnet DC V, DC V. Electrical Data Power Supply DC V, ±10%, 0.7 W Duct Sensor Humidity / Temperature For measuring the relative or absolute humidity and temperature in duct applications. The measured values and absolute humidity, dewpoint and enthalpy are transmitted

More information

7110 MTF-FG. Transmitter for Turbidity and Solids Content ISO Technical Information TI 232e

7110 MTF-FG. Transmitter for Turbidity and Solids Content ISO Technical Information TI 232e Technical Information TI 232e00 51508353 Transmitter for Turbidity and Solids Content The transmitter is used for optical solid matter content measurement in clear and turbid water and in sludge. Since

More information

Portable pressure calibrator Model CPH7600

Portable pressure calibrator Model CPH7600 Calibration technology Portable pressure calibrator Model CPH7600 WIKA data sheet CT 17.01 Wally Box III Applications Calibration service companies and service industry Measurement and control laboratories

More information

Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature with calibration certificates

Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature with calibration certificates 1 883 1883P01 1883P02 QFM4160 AQF4150 Symaro Duct Sensors for relative humidity and temperature with calibration certificates QFM41 Operating voltage AC 24 V / DC 1353 Signal output DC 010 V / 420 ma for

More information

Ultrasonic Heat Flow Meters

Ultrasonic Heat Flow Meters APPLICATIONS Measuring heat flow Sewage and drainage water with small particle quantity Beverage and food processors HVAC hot and cool water Water and waste treatment Power plants, heat energy boiler feed

More information

Pneumatic precision pressure controller Model CPC6000

Pneumatic precision pressure controller Model CPC6000 Calibration technology Pneumatic precision pressure controller Model CPC6000 WIKA data sheet CT 27.61 Applications Industry (laboratory, workshop and production) Transmitter and pressure gauge manufacturers

More information

BT300 HVAC Drives. Designed for HVAC. Description. Technical Specification Sheet Document No March 4, 2013

BT300 HVAC Drives. Designed for HVAC. Description. Technical Specification Sheet Document No March 4, 2013 Technical Specification Sheet Document No. 149-711 March 4, 2013 BT300 HVAC Drives Designed for HVAC Figure 1. BT300 HVAC Drive without and with Integral Disconnect. Description Siemens Industry's BT300

More information

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1 ) ATÜVRheinland Precisely Right. CERTIFICATE of Product Conformity (QAL1 ) Certificate No.: 0000035007 01 Certified AMS: Manufacturer: Test lnstitute: D-EMS 2000 DURAG data systems GmbH Kollaustr.105 22453

More information

QXA2000 QXA2001. Condensation Monitor QXA2001 QXA2000 AQX2000

QXA2000 QXA2001. Condensation Monitor QXA2001 QXA2000 AQX2000 1 542 1542P03 1542P01 1542P02 QXA2001 QXA2000 AQX2000 Condensation Monitor QXA2000 QXA2001 The QXA2000 condensation monitor is used to avoid damage due to condensation on chilled ceilings and in HVAC plant.

More information

Ultra Sonic Flowmeter DATASHEET

Ultra Sonic Flowmeter DATASHEET Ultra Sonic Flowmeter DATASHEET JUNHO 2013 ULTRASONIC-FLOWMETER NON-INVASIV / CLAMP-ON-SENSORS Type: IS210-S Technical Information 2013 FLOW THE EXPERT IN LEVEL AND FLOW IS210 Technical Information Intra-Automation

More information

Gas-actuated thermometer Stainless steel version Model 73

Gas-actuated thermometer Stainless steel version Model 73 Temperature Gas-actuated thermometer Stainless steel version Model 73 WIKA data sheet TM 73.01 for further approvals see page 15 Applications General process instrumentation in the chemical and petrochemical

More information

DATASHEET ULTRASONIC COMPACT ENERGY METER MODEL 773

DATASHEET ULTRASONIC COMPACT ENERGY METER MODEL 773 APPLICATION Static compact energy meter using ultrasonic technology Highly accurate recording of all billing data in local and district heating and cooling systems FEATURES 1st. approval in Europe for

More information

Continuous Dew Measurement in Explosive Area for flammable and non-flammable gases. VASTHI ENGINEERS

Continuous Dew Measurement in Explosive Area for flammable and non-flammable gases. VASTHI ENGINEERS Sheet No. 1 of 5 Continuous Dew Measurement in Explosive Area for flammable and non-flammable gases. Sheet No. 2 of 5 Vasthi Engineers Moisture Analyzer Model VMA 888 is heavy duty, industrial hygrometer

More information

Exposure Monitoring HEALTH AND SAFETY

Exposure Monitoring HEALTH AND SAFETY HEALTH AND SAFETY Exposure Monitoring SIDEPAK Personal Aerosol Monitor Model AM510 The SIDEPAK AM510 Personal Aerosol Monitor for industrial hygiene and safety professionals displays and data logs aerosol

More information

Output Signal Active Note DC V. Electrical Data Power Supply DC V, ±10%, 1.4 W

Output Signal Active Note DC V. Electrical Data Power Supply DC V, ±10%, 1.4 W Differential Pressure Sensor (Air) Differential pressure transmitter with 8 selectable ranges 0 to 5/10 V, 4 to 20 ma outputs and Modbus functionality. NEMA 4X / IP65 rated enclosure. For monitoring the

More information

SAX.. ACVATIX Electromotive actuators for valves. with a 20 mm stroke

SAX.. ACVATIX Electromotive actuators for valves. with a 20 mm stroke s 4 501 ACVATIX Electromotive actuators for valves SAX.. with a 20 mm stroke SAX31.. Operating voltage AC 230 V, 3-position control signal SAX61.. Operating voltage AC/DC 24 V, control signal DC 0 10 V,

More information

Pulverised Fuel Flowmeter

Pulverised Fuel Flowmeter Data Sheet SS/PFMAS_ PfMaster! On-line measurement of pulverized-fuel (pf) distribution (pf split), velocity and mass flowrate improved burner and boiler stoichiometry! Measurement across total cross-section!

More information

IS-3000-LS-ABB INFRARED SCANNER

IS-3000-LS-ABB INFRARED SCANNER IS-3000-LS-ABB INFRARED SCANNER NON-CONTACT, RELIABLE, PRECISE, LONG RANGE POSITIONING FOR HOT OR COLD PRODUCTS FEATURES: SIMULATES ORIGINAL ABB PULSE OUTPUT AUTOMATIC GAIN CONTROL ADJUSTABLE SCAN ANGLE

More information

ABB MEASUREMENT & ANALYTICS DATA SHEET. IT1 Universal weighing terminal

ABB MEASUREMENT & ANALYTICS DATA SHEET. IT1 Universal weighing terminal ABB MEASUREMENT & ANALYTICS DATA SHEET IT1 Universal weighing terminal 2 IT1 UNIVERSAL WEIGHING TERMINAL DS/IT1-EN REV. A Measurement made easy Suitable for difficult environmental conditions and locations

More information

LUMIOS MkIII Luminance Photometer for Tunnels

LUMIOS MkIII Luminance Photometer for Tunnels Designed specifically measurement of luminance at the tunnel portal or within the tunnel CIE Approved measurement of L20 Variable viewing angle within a range of 10 to 40º available Silicon photo diode,

More information

EN English. Operation and installation manual. SeasyParticle 230. Particle counter for compressed air and gases. SeasyParticle 230 Page 1 of 15

EN English. Operation and installation manual. SeasyParticle 230. Particle counter for compressed air and gases. SeasyParticle 230 Page 1 of 15 EN English Operation and installation manual SeasyParticle 230 Particle counter for compressed air and gases SeasyParticle 230 Page 1 of 15 Contents II. Contents II. Contents... 2 1 Safety advice... 3

More information

Precision digital pressure gauge Model CPG1500

Precision digital pressure gauge Model CPG1500 Calibration technology Precision digital pressure gauge Model CPG1500 WIKA data sheet CT 10.51 for further approvals see page 4 Applications Oil and gas industry Maintenance and service facilities Calibration

More information

DMT PERFORMING UNDER PRESSURE DMT. Applications. Special features. Description 1/9

DMT PERFORMING UNDER PRESSURE DMT. Applications. Special features. Description 1/9 Applications Industry (laboratory, workshop and production) Transmitter and pressure gauge manufacturers Calibration service companies and service industry Research and development laboratories National

More information

Pneumatic precision pressure controller Model CPC6000

Pneumatic precision pressure controller Model CPC6000 Calibration technology Pneumatic precision pressure controller Model CPC6000 WIKA data sheet CT 27.61 Applications Industry (laboratory, workshop and production) Transmitter and pressure gauge manufacturers

More information

Sono-Trak Transit Time Clamp-on Ultrasonic Flow Meter

Sono-Trak Transit Time Clamp-on Ultrasonic Flow Meter A trademark of Spirax Sarco, Inc. Sono-Trak Transit Time Clamp-on Ultrasonic Flow Meter Description Engineered for performance excellence, the Sono-Trak Transit Time ultrasonic meter combines non-invasive,

More information

Performance and Efficiency

Performance and Efficiency 01 GB Performance and Efficiency Compressed air management system Superior control solutions SmartAir Master Efficiency. Performance. Monitoring. Great energy saving potential Energy management is crucial

More information

The PM1000 series is a universal 4 digit LED plug-on display for transmitters with 4-20mA 2 wire output and fitted with DIN43650 connector.

The PM1000 series is a universal 4 digit LED plug-on display for transmitters with 4-20mA 2 wire output and fitted with DIN43650 connector. PM1000 SERIES PLUG-ON DISPLAY BRIGHT LED DISPLAY INDICATION RANGE -999 TO +9999 FITS TO DIN 43650 CONNECTOR PLUG-ON TO ANY TRANSMITTER WITH 4-20MA OUTPUT EASY TO SCALE ON SITE ROBUST DESIGN SET POINT OPTION

More information

TEMPERATURE AND HUMIDITY TRANSDUCER P18 TYPE USER S MANUAL

TEMPERATURE AND HUMIDITY TRANSDUCER P18 TYPE USER S MANUAL TEMPERATURE AND HUMIDITY TRANSDUCER P18 TYPE USER S MANUAL 1 2 CONTENTS 1. APPLICATION... 5 2. BASIC REQUIREMENTS, OPERATIONAL SAFETY... 5 3. INSTALLATION... 5 3.1. Assembly...5 3.2. Electrical Connections...7

More information

Smart. Simple. Reliable. 600mm 1,100mm 600mm ( ft.) Weight 80 kg (176.4 lb.) [1] Protection Rating Ground-Mounted, Wall-Mounted, Rack-Mounted

Smart. Simple. Reliable. 600mm 1,100mm 600mm ( ft.) Weight 80 kg (176.4 lb.) [1] Protection Rating Ground-Mounted, Wall-Mounted, Rack-Mounted ACU2000 Series ACU2000 ( Array Controller Unit) is a powerful integration of PV array communication and other smart functions. built-in Anti-PID module built-in (optional) Multiple communication interfaces

More information

CALEC energy master The benchmark in energy measurement

CALEC energy master The benchmark in energy measurement CALEC energy master The benchmark in energy measurement District heating and cooling: New tariff structures for optimum plant management Secure investment with long-term stability Type approval to EU/2004/22

More information

DCT 531. Industrial Pressure Transmitter with RS485 Modbus RTU. Stainless Steel Sensor

DCT 531. Industrial Pressure Transmitter with RS485 Modbus RTU. Stainless Steel Sensor DCT 5 Industrial Pressure Transmitter with RS85 Modbus RTU Stainless Steel Sensor accuracy according to IEC 60770: : 0.5 % FSO option: 0.5 % FSO Nominal pressure from 0... 00 mbar up to 0... 00 bar output

More information

Dräger Polytron IR. Dräger Polytron IR: Configurable gas detector for reliable detection of combustible gases and vapours.

Dräger Polytron IR. Dräger Polytron IR: Configurable gas detector for reliable detection of combustible gases and vapours. DETECTION PERSONAL PROTECTION DIVING TECHNOLOGY SYSTEM TECHNOLOGY SERVICES Dräger Polytron IR ST-3949-2004 The Dräger Polytron IR is an explosion proof infrared gas detector for continuous monitoring of

More information

Clamp-On Transit Time Ultrasonic Flow Meters

Clamp-On Transit Time Ultrasonic Flow Meters APPLICATIONS Water (hot water, cooling water, potable water, sea water etc.) Petroleum products Chemicals, including alcohol, acids, etc HVAC, energy measurement system Beverage, food and pharmaceutical

More information

Portable low-pressure controller Model CPC2000

Portable low-pressure controller Model CPC2000 Calibration technology Portable low-pressure controller Model CPC2000 WIKA data sheet CT 27.51 Applications Mobile calibration of low-pressure measuring instruments Supply of very low positive or negative

More information

High-end pressure controller Model CPC8000

High-end pressure controller Model CPC8000 Calibration technology High-end pressure controller Model CPC8000 WIKA data sheet CT 28.01 Applications Industry (laboratory, workshop and production) Transmitter and pressure gauge manufacturers Calibration

More information

Clear Benefits of the KRAL Electronic.

Clear Benefits of the KRAL Electronic. Clear Benefits of the KRAL Electronic. Coordinated to the flowmeters and their applications. Users of conventional universal display units often cannot make use of their device s options. There is often

More information

System Overview Fuel/air ratio control system VMS. Sensors and systems for combustion engineering.

System Overview Fuel/air ratio control system VMS. Sensors and systems for combustion engineering. System Overview Fuel/air ratio control system VMS Sensors and systems for combustion engineering www.lamtec.de LAMTEC Fuel/air ratio control system VMS Approvals. EC Type Examination Certificate (Module

More information

Micro Motion Model 7950 and Model 7951 Signal Converters

Micro Motion Model 7950 and Model 7951 Signal Converters Product Data Sheet PS-001316, Rev. B April 2013 Micro Motion Model 7950 and Model 7951 Signal Converters Micro Motion Model 7950 and Model 7951 signal converters are the perfect complement to Micro Motion

More information

High-end pressure controller Model CPC8000

High-end pressure controller Model CPC8000 Calibration technology High-end pressure controller Model CPC8000 WIKA data sheet CT 28.01 Applications Industry (laboratory, workshop and production) Transmitter and pressure gauge manufacturers Calibration

More information

TRANSMITTERS. HygroFlex & HygroClip-EX. Applications. Highlights

TRANSMITTERS. HygroFlex & HygroClip-EX. Applications. Highlights HygroFlex & HygroClip-EX HygroFlex series may be used together with the intrinsically safe HygroClip-EX probes. The relative humidity and temperature can be displayed and output as analog signals. Calculated

More information

Sensor for car parks and tunnels

Sensor for car parks and tunnels Page 1 Sep. 2017 system with exchangeable sensor element including digital value processing, temperature compensation and selfmonitoring algorithm for the continuous sensing and control of the ambient

More information

C500 Series Data Sheet

C500 Series Data Sheet C500 Series Data Sheet - 16 x 350Ω load cells - AC and DC versions - Ethernet and USB host and slave standard - 10,000d @ 0.5 µv/d - 8 set points (option) - Analog module with 2 isolated outputs (option)

More information

IDS 500 mobile Intelligent mobile chart recorder

IDS 500 mobile Intelligent mobile chart recorder IDS 500 mobile Intelligent mobile chart recorder The intelligent mobile chart recorder - energy analysis according to DIN EN ISO 50001 Energy analysis - ow measurement - leakage calculation at compressed

More information

Innovation on Medium Voltage Switchgear

Innovation on Medium Voltage Switchgear Bruno Rivas, Guarulhos - Brazil, April 2015 Jornadas Técnicas de ABB en Chile Innovation on Medium Voltage Switchgear May 13, 2015 Slide 1 Application 13. Mai 2015 Slide 2 PPMV Brazil Factory Unigear Insourcing

More information

Float Switches with Permanent Magnet For Vertical Installation Model RSM

Float Switches with Permanent Magnet For Vertical Installation Model RSM Level Measurement Float Switches with Permanent Magnet For Vertical Installation Model RSM WIKA Data Sheet LM 30.01 Applications Level measurement for almost all liquid media Pump/level control and monitoring

More information

PATENT PENDING RABBIT EARS THERMOELECTRIC GENERATOR

PATENT PENDING RABBIT EARS THERMOELECTRIC GENERATOR Introduction: The Rabbit Ears CHP (Combined heat & power) is a Thermoelectric wood stove Generator Nominally rated at 100 watts. It has the ability to supply reliable solid-state power. The ONLY moving

More information

T EN TROVIS Electropneumatic Positioner

T EN TROVIS Electropneumatic Positioner T 8484-1 EN TROVIS 3730-1 Electropneumatic Positioner Application Single-acting positioner for attachment to pneumatic globe and rotary valves. Self-calibrating, automatic adaptation to valve and actuator.

More information

Analog Output Isolators

Analog Output Isolators TURCK Interface Technology Analog output isolators are for use with conventional 4/20 ma or HART smart "IS" devices are available in 1 and 2 channel versions. These devices are designed to provide a convenient

More information

Chart recorder. DS 500 mobile Intelligent mobile chart recorder

Chart recorder. DS 500 mobile Intelligent mobile chart recorder DS 500 mobile Intelligent mobile chart recorder The intelligent mobile chart recorder - energy analysis according to DIN EN ISO 50001 Energy analysis - ow measurement - leakage calculation at compressed

More information

Application The DA03 serves as indicator of differential. Follow mounting instructions in accordance to application.

Application The DA03 serves as indicator of differential. Follow mounting instructions in accordance to application. DA03 Differential Pressure Gauge / Differential Pressure Gauge and Switch Models for Assignment in Explosion-hazardous Areas per Directive 94/9/EC (ATEX) Application The DA03 serves as indicator of differential

More information

FOR LIQUIDS AND SOLIDS

FOR LIQUIDS AND SOLIDS FOR LIQUIDS AND SOLIDS LEVEL SWITCHES VIBRATING FORK LEVEL SWITCHES O U R P R O F E S S I O N NIVOSWITCH VIBRATING FORK LEVEL SWITCHES MAIN FEATURES and mini compact type Rod extension up to 3 meters (10

More information

Online data sheet MEAC CEMS SOLUTIONS

Online data sheet MEAC CEMS SOLUTIONS Online data sheet MEAC A B C D E F H I J K L M N O P Q R S T Ordering information Type MEAC Part no. On request The exact device specifications and performance data of the product may deviate from the

More information

adjustment via factory default or directly on the sensor signal display flashing at threshold undercut or /exceedance

adjustment via factory default or directly on the sensor signal display flashing at threshold undercut or /exceedance Processor-based bargraph with digital display vertical or horizontal MB3 3-digit digital display -199 999 red display, optional green 30 dots bargraph display tricolour adjustment via factory default or

More information

Universal IV Water Cut Meter

Universal IV Water Cut Meter DREXELBROOK DATA SHEET Universal IV Water Cut Meter with Density Compensation Use the Best For over 50 years, Drexelbrook has been the world s leader in capacitive based measurements by providing reliable

More information

DigitalFlow GC868 Panametrics Clamp-On Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features

DigitalFlow GC868 Panametrics Clamp-On Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features Applications The DigitalFlow GC868 clamp-on gas flowmeter is a complete ultrasonic flow metering system for measurement of most gases, including: Natural gas Compressed air Fuel gases Erosive gases Corrosive

More information

CERTIFICATE. on Product Conformity (QAL 1) Number of Certificate: DURAG data systems GmbH Kollaustr Harnburg Germany

CERTIFICATE. on Product Conformity (QAL 1) Number of Certificate: DURAG data systems GmbH Kollaustr Harnburg Germany Umwelt Bundes A_ TÜVRheinland Amt Precisely Right. f or our Environment CERTIFICATE on Product Conformity (QAL 1) Number of Certificate: 0000035007 Certified AMS: Manufacturer: Test Institute: D-EMS 2000

More information

IN-LINE. vpinstruments.com

IN-LINE. vpinstruments.com VPFLOWSCOPE IN-LINE vpinstruments.com VPFlowScope In-line The VPFlowScope In-line measures flow, pressure and temperature simultaneously. It is the perfect solution for compressed air and technical gas

More information