1 DIGITAL PRESSURE SENSOR SCANNER CUM DATALOGGER MODEL : NICTECH-DAQ-PRESSURE-16X-USB (FRONT & REAR VIEW WITH CONNECTORS FOR STRAIN GAUGE INPUT) FEATURES Internal scanner provides 8 measuring channels as standard and is Extensible to a maximum of 96 channels Composes of bridge, the largest transmission distance: 50 mtrs Suitable for Static strain test of bridges, railways and other major Engineering Applications. Readings directly in microstrains SCANS EACH CHANNEL ONE BY ONE ON LCD BUT TRANSFER DATA FOR ALL THE CHANNELS SIMULTANEOUSLY ON PC BASED SOFTWARE IN THE SELECTED SAMPLING RATE METAL HOUSING WITH POWDER COATINGS FRINT ENDED KEYPAD FOR ZERO/TARE AND ENTERING CALIBRATION FACTOR Page 1
2 TECHNICAL SPECIFICATIONS Input Range +/ BAR Resolution 0.01BAR channels (single module) 16 Tolerance ±0.3% FS± Scanning speed Max 5 csamples per sec for STATIC TEST. LCD backlit Alphanumeric indication of the output measured values Long wire automatic compensation. 12-bit dual D / A auto-balance. Suitable for testing general strain in metal, concrete structures in STATIC MODE only Interface : PC serial Interface RS-232, 9-pin D - Connector Bridge Resistance Ω (Gauge Factor= ) Impedance to be specify while ordering Bridge Full Common Compensation (any of the one type to be specified) Sensitivity ±0.02%FS/ C Temperature/Humidity Operating Temperature :0 to 50 C; Page 2
3 Operating Humidity: 20 to 80% RH Power Supply AC:220V50Hz/0.5A; DC:+12 to +40V Dimensions WIDTH(10 ),HEIGHT(3.8 INCH), DEPTH 30 INCH Input/Output Type Input:4-Pin Metal circular Socket ; Output: BNC Weight 1.5Kg single module (16 channels) Long wire automatic compensation SUPPLIED WITH Accessories : input/output cable: one/ch Accessories Power supply cable:1 RS-232 serial Cable-1 No. Calibration chart Software series CD- 1No. Page 3
4 DATA LOGGERS CHANNELS Page 4
5 LCD DISPLAY UNIT IN BAR KEYPADS DATA LOGGER DAM-XC-USB-350-SERIES SERIAL DATA TX PORT TO USB OF LAPTOP 8 GB USB PENDRIVE CONNECTORS 16 CHANNEL DATA LOGGER DAM Page 5
6 1.1 INSTALLATION & OPERATING MANUAL 1. KEEP THE DATALOGGER IS SWITCH OFF CONDITION. 2. MAKE THE CONNECTORS OF THE UNIAXIAL STRAIN GAUGES AS BELOW: 3. CONNECT THE CONNECTOR OF STRAIN GAUGE TO RESPECTIVE END CONNECTORS PLACED AT REAR SIDE OF DATALOGGER. NOW SWITCH ON THE INDICATOR ON PLUG OFF 4. LCD WILL DISPLAY CH 01 = ms CH 02 = ms 5. IF SOME VALUE IS COMING ON LCD WHEN SWITH IS ON THE DAM SERIES INSTRUMENT, TARE THE SAME BY PRESSING MENU KEY 1 NO TIME AND LCD DISPLAY ASKED FOR SET TARE NO PRESS ENTER TO TARE THE INITIAL STRAIN VALUES. PLEASE TAKE CARE THAT STRAIN GAUGES SHOULD PASTED ON THE TESTING SOFTWARE. Page 6
7 6. PLEASE OFFER INSTRUMENT MINUTES WARM UP TIME. 7. AGAIN TARE THE READINGS BY PROCCESSING MENU AND THE ENTER NO 8. NOW CHECK THE COUNTS AFTER STEP FOR CHECKING COUNTS, SWITCH OFF THE INDICATOR, KEEP ON PRESSING ENTER AND SWITCH ON THE INDICATOR, PLEASE KEEP ENTER PRESSED UNTIL DISPLAY SHOWN: CH 01 = ms CH 02 = ms 10. NOW RELEASE THE ENTER KEY, LCD DISPLAY WILL SHOW: A 01 = A 02 = TO VERYFY THE COUNT RATINGS OF OHER CONNECTED CHANNELS, PRESS INC key to switch over to ch 3, ch4,..ch NOW APPLY LOAD TO THE TESTINGSTRUCTURE THE LCD DISPLAY THE MICROSTRAIN VALUES OF CH 1, CH2 AND PRESS INC KEY TO SEE THE VALUES OF REST OF THE CHANNELS. 12. TO CONTONUSLY SEE THE MEASURED VALUES OF ALL THE CONNECTED CHANNELS, PRESS SHIFT KEY, ALL CHANNELS WILL START SCROLLING. TO RELEASE SCROLLING AGAIN PRESS SHIFT KEY. LCD DISPLAYS MODE CHANGE AND ONLY TWO CHANNELS WILL BE DISPLAYED. Page 7
8 1.2 DATA TRANSFER TO PC AND USB PENDRIVE 1. DATA TRANSFER TO PC FOR DATA TRANSFER TO PC BASES REAL TIME DISPLAY AND LOGGING SOFTWARE, PLEASE PRESS MENU KEY TWICE, LCD NO DISPLAY SHOWS. CHANGE DELAY NO PRESS ENTER KEY, LCD WILL DISPLAY. LOG DELAY USE INC AND SHIFT KEY TO ENTER FOLLOWING VALUE. AND AFTER ENTERING, 00001, PRESS ENTER TO SAVE THE SAME. THIS FACTOR WILL ALLOW DATA TO TRAVEL TO PC BASED SOFTWARE. 2. DATA TRANSFER TO USB PENDRIVE PLEASE INSERT THE USB PENDRIVE 2 GB/ 4 GB/ 8 GB AT THE USB PORT SLOT PROVIDED AT THE REAR END THE DATA LOGGER. PRESS MENU TWICE, LCD WILL DISPLAY LOG DELY. USE INC AND NO SHIFT KEY TO ENTER Page 8
9 FOLLOWING VALUES: AND AFTER ENTERING 00011, PRESS ENTER TO SAVE THE SAME. THIS FACTOR WILL ALLOW DATA TO TRAVEL TO USB. ONCE THE TEST IS COMPLETED PRESS THE RE- SET SWITCH PROVIDED AT REAR END TO THE DATA- LOGGER AND TAKE OUT THE USB PENDRIVE. ONCE YOU TAKE OUT THE PENDRIVE RELEASE THE RESET SWITCH, UNTILL THEN KEEP IT PRESSING. NOW PLUG THE USB DRIVE TO PC AND OPEN IT, THE LOGGING FILE WILL APPEARED. THEN RIGHT CLICK AND OPEN THE SAME USING EXCEL. A MICROSOFT EXCEL SPREADSHEET WILL BE OPENED WITH ALL REAL TIME READINGS OF THE CONNECTED CHANNELS. NOTE: THE DAM SERIES IS FACTORY CALIBRATED FOR STRAIN, PRESSURE, LOAD, TORQUE, LVDT ETC. PLEASE DO NOT CHANGE THE CALIBRATION MENU. FOR RE- CALIBRATION PLEASE CONTACT TO SUPPLIER, AUTHORIZED DEALER. Page 9
10 1.2 SOFTWARE INSTALLATION MENU Data.txt -3 SOFTWARE FILES 1. Please download all the above three file and place them in a New Folder On Desktop. 2. Connect the RS-232 wire to Serial Port of The Desktop PC as well as The 9-pin Serial port of the Strain Indicator 3. Please keep the Indicator in SWITCH OFF Position while connecting Connectors. 4. Now Switch ON the Indicator 5. LCD display will Indicate STRAIN CHANNEL 1-4 NOS 6. Press MENU First,Display will Indicate TARE ALL with &NO options NO 7. Press ENTER Key, This will Tare all the Initial Offset values and place the starting NO LOAD values of strain gauges connected as microstrains Page 10
11 8. Now Open the Software Folder as placed on the PC Desktop. Data.txt - These 3 file will be opened. Click the File and the Software will start working.,the Software Window will be displayed as below upon clicking the ICON,please do not click rest of the two files 9. In Column DATA TRANSFER MESSAGE if Data Transfer from Indicator is coming properly then the message will be as. Data coming.ok, in case of any transfer error it will be Data Coming Not Responding 10. In case of Data Transfer Error, Press Set UP MENU and click PORT as Indicated below. Page 11
12 Page 12
13 11.On clicking PORT,The following Message will appear, please select the COM-1 or COM-2(in case your PC has more than 1 COM ports) and Baud Rate as TARE initial Values by Pressing Front ended keypad,press MR/< KEY First,Display will Indicate TARE ALL with & NO options.press T/Z to enter, TARE all initial values after connecting TORQUE SENSOR is must in each and every test at Page 13
14 starting stage, You can TARE once/twice to achieve ZERO No Load values 12. Enter the Log Delay as per the Scanning rate required, Ex. 10 numeric value indicates 3 sampling cycles per seconds,60 numeric value means next samples will be after 20 seconds, Min value to be entered is Real time value in EXCEL file will automatically generated and stored on the PC desktop as below- Page 14
15 STRAIN INDICATOR HARDWARE DESIGN Specifications 1. Application Range: Widely apply in weighing system equipped with 1 CH 4 -wire sensor 2. Standard function: -High precision A/D conversion with readability 1/30,000 -Auto adjustment speed and range of digital filter -Auto power-saving mode -Protection for low battery -AC/DC Power supply, built-in rechargeable battery 6V/4AH battery -Accumulation auto/manual -10 times enlargement of weight value(counts 10,000) -Hold function -kg/lb units conversion -RS232C with selectable baud rate 3. Technical Parameter: -A/D conversion method: Tri-Integral -AD conversion: 40 times/sec. -Input signal:0-10mv -Input sensitivity: 1μV/e -Load Cell excitation: DC5V -Connection of 1 strain gauge SENSOR(350Ω) -Verified counts: Max. external counts: 30,000 -Division:1/2/5/10/20/50 optional -Display: LCD Back Lit 4. -Simulating voltage: DC5V -Transmission distance: RS232C 30 meters -Power Supply: AC187 ~ 242V,49-51 Hz; DC built-in rechargeable 6V/4AH battery -Ambient temperature: 0 ~ 40 C 5. Option: RS232C serial communication interface, with selectable baud rate by continuous sending method Page 15
16 DESIGN &MKTD By : M/s N I C JAIPUR(a sensors & Automation co.) NICTECH nic_s@rediffmail.com, nic_jpr@indiatimes.com Page 16
GMC-206/215/230 Digital Desktop Weighing Scale Operation Manual
GMC-206/215/230 Digital Desktop Weighing Scale Operation Manual Version 2.1 Gamma Scale Tel: (905) 455-8333 Fax: (905) 455-0658 E-mail: info@gammascale.com Website: www.gammascale.com 1. Technical Parameters
More informationUSER S GUIDE. Weighing Indicator. globalindustrial.com. Use of RS232 Port Using Windows for the Printer Driver, Adjust Computer Settings as Follows:
Use of RS232 Port Using Windows for the Printer Driver, Adjust Computer Settings as Follows: Click On Start Pick Program Weighing Indicator USER S GUIDE Pick Accessories Pick Communications Pick Hyper
More informationSY021 Portable Load/Force Meter User instructions
SY021 Portable Load/Force Meter User instructions Relates to firmware version 5.2 INTRODUCTION The SY021 is a portable load meter, which can indicate the load present on any attached cell. A dual channel
More informationUWE-1707 SERIES CONTENTS OPERATION MANUAL ELECTRONIC WEIGHING INDICATOR 1. SPECIFICATIONS 2. INSTALLATION
UWE-1707 SERIES CONTENTS ELECTRONIC WEIGHING INDICATOR OPERATION MANUAL 1. SPECIFICATIONS PLEASE READ THIS MANUAL VERY CAREFULLY BEFORE ATTEMPT TO OPERATE THE SCALE 2. INSTALLATION 3. ROUTINE OPERATION
More information2-2 Testing space Tension and Compression test can be available at the lower section of movable crosshead. Upper tension type : Sold separately.
1.General Specifications TECHNO GRAPH This TECHNO GRAPH, universal testing machine has developed with the concept of achieving Fulfillment of functions and simple operations. Adopted with AC servo motor,
More informationNI2400/NI816/NI4866 DATALOGGER NI2400/NI816/NI /16/24 CHANNEL ETHERNET DATA LOGGER with Embedded Web Server
DATALOGGER NI2400/NI816/NI4866 8/16/24 CHANNEL ETHERNET DATA LOGGER with Embedded Web Server DATASHEET Rev. 08 del 08/10/2018 Redatto da R&D Approvato da MKT GENERAL 1SPECIFICATIONS NI4866 NI816 NI2400
More informationDC-204R DC-204Ra SMART DYNAMIC STRAIN RECORDER. 200kHz 2GB UPS. Strain DC voltage Temperature. TML Pam E-442B. capacity. High speed sampling
TML Pam E-442B SMART DYNAMIC STRAIN RECORDER Standard With analog output DC-204R DC-204Ra Strain DC voltage Temperature High speed sampling 200kHz Large data recording 2GB capacity Automatic data storing
More informationSD Model. Instruction Manual. Sound Level Meter/ Data logger. reedinstruments. www. com
Model SD-4023 Sound Level Meter/ Data logger Instruction Manual www com Table of Contents Features... 3 Specifications...4-5 Instrument Description... 6 Operating Instructions...7-11 Function Selection...
More informationEDX-10 Series. Compact Recording System
3-51 EDX-10 Series Compact Recording System Compact & lightweight, with a simple configuration, all channels synchronous 20 khz high-speed sampling (For 4 channels) Control Unit EDX-10B A unit controls
More informationEDX-10 Series. Compact Recording System
3-49 EDX-10 Series Compact Recording System Compact, lightweight, with a simple configuration, all channels synchronous 20 khz high-speed sampling (For 4 channels) Control Unit EDX-10B A unit controls
More informationC100 Portable Multifunction
C100 Portable Multifunction Superior Accuracy as compared to Competitors! Wahl C100 Simultaneous Measurement and Generation Rugged IP54 Construction for On Site Use Quick Connect Terminals Measurement
More informationLAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description
Description LAUREL ELECTRONICS, INC. Features Laureate Digital Panel Meter for Load Cell & Microvolt Input 20, 50, 100, 250 & 500 mv ranges Span adjust from 0 to ±99,999, zero adjust from -99,999 to +99,999
More informationWeighing Indicator USER S GUIDE. globalindustrial.com. globalindustrial.com. 11 Harbor Park Drive Port Washington, NY 11050
Weighing Indicator USER S GUIDE 0713 11 Harbor Park Drive Port Washington, NY 11050 Table of Contents I Main Specifications.............................3 II Display and Keyboard..........................4
More informationDatalogging Hygro-Thermometer
USER MANUAL Datalogging Hygro-Thermometer Model SD500 Introduction Congratulations on your purchase of the Extech SD500 Temperature/Humidity Datalogger. This meter measures, displays, and stores temperature
More informationLAUREL. Laureate Digital Panel Meter for Process and Ratiometric Signals ELECTRONICS, INC. Features. Description
LAUREL ELECTRONICS, INC. Laureate Digital Panel Meter for Process and Ratiometric Signals Features Reads process signals from ±200 mv to ±600V or ±2 ma to ±5A full scale Ratiometric mode for bridges and
More informationFG-7000L Digital Force Gauge Operation Manual
FG-7000L Digital Force Gauge Operation Manual Operators should wear protection such as a mask and gloves in case pieces or components break away from the unit under test. Whether the unit is ON or OFF,
More informationTTC Series Torque Tool Tester Operation Manual
TTC Series Torque Tool Tester Operation Manual Operators should wear protection such as a mask and gloves in case pieces or components break away from the unit under test. Whether the unit is ON or OFF,
More informationFG-7000 Digital Force Gauge Operation Manual
FG-7000 Digital Force Gauge Operation Manual Operators should wear protection such as a mask and gloves in case pieces or components break away from the unit under test. Whether the unit is ON or OFF,
More informationSY061 Portable Load Meter with IEEE TEDS capability User Instructions
SY061 Portable Load Meter with IEEE1451.4 TEDS capability User Instructions Preliminary, relates to firmware version 1.2i Introduction The SY061 is a portable load meter, which can indicate the load present
More informationMP-2000 Dual Channel LVDT/RVDT Readout/Controller
Large backlit dual channel display Menu driven setup and calibration 100 to 240 VAC line powered MIN, MAX, TIR, A+B and A-B functions 2.5, 3.3, 5 and 10kHz selectable excitation Analog and RS232 outputs
More informationWeighing Indicator. Features. Description. Applications
Force Pressure Temperature Switch Weighing Indicator Description The compact Indicator of model E1932X is a precision and cost effective product for weighing applications. They are ideal for use in mobile
More informationOPERATION MANUAL. SD card real time datalogger 3 channels 4-20 ma CURRENT RECORDER. Model : MMA-386SD
SD card real time datalogger 3 channels 4-20 ma CURRENT RECORDER Model : MMA-386SD Your purchase of this 3 channels 4-20 ma CURRENT RECORDER marks a step forward for you into the field of precision measurement.
More informationUser's Guide. Datalogging Hygro-Thermometer Model SD500
User's Guide Datalogging Hygro-Thermometer Model SD500 Introduction Congratulations on your purchase of the Extech SD500 Temperature/Humidity Datalogger. This meter measures, displays, and stores temperature
More informationEXCELL PRECISION CO., LTD.
Excell Precision Limited 24. All rights reserved Worldwide. The information contained herein is the property of Excell Precision Limited and is supplied without liability for errors or omissions. No part
More informationSD Model. Instruction Manual. Humidity/Temperature Datalogger. reedinstruments
Model SD-3007 Humidity/Temperature Datalogger Instruction Manual reedinstruments com 1-877-849-2127 info@reedinstruments.com.reedinstruments.com Table of Contents Features... 3 Specifications...3-5 Instrument
More informationCALOG CALOG - LC DISPLAY. Loadcell Display. English Users Manual. Rev. 1.10
CALOG C A L I B R AT O R S CALOG - LC DISPLAY Loadcell Display English Users Manual Rev. 1.10 Table of Contents! Contents! 1.0 Introduction...2! 2.0 Getting Started...2! 2.1 Keypad...2! 2.2 Display...2!
More informationStrain gauge Measuring Amplifier GSV-1A8. Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB
Strain gauge Measuring Amplifier GSV-1A8 Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB GSV-1A8USB SubD1 (front side) GSV-1A8USB M12 (front side) GSV-1A16USB (rear side) GSV-1A8USB K6D (front side)
More informationVibration Meter SD Card real-time datalogger
User's Guide Vibration Meter SD Card real-time datalogger Model SDL800 Introduction Congratulations on your purchase of the Extech SDL800 Vibration Meter. This meter displays and stores vibration readings
More informationAC/DC MAGNETIC METER OPERATION MANUAL. Model : MG G ( Gauss), mt ( milli Tesla ), USB/RS232. Your purchase of this
G ( Gauss), mt ( milli Tesla ), USB/RS232 AC/DC MAGNETIC METER Model : MG-3002 Your purchase of this AC/DC MAGNETIC METER marks a step forward for you into the field of precision measurement. Although
More informationBarometric Pressure / Humidity and Temperature Datalogger
USER MANUAL Barometric Pressure / Humidity and Temperature Datalogger Model SD700 Introduction Congratulations on your purchase of the Extech SD700 Humidity/Barometric Pressure/Temperature Datalogger.
More informationph/orp Meter SD Card real-time Datalogger
User's Guide ph/orp Meter SD Card real-time Datalogger Model SDL100 Introduction Congratulations on your purchase of the Extech SDL100 ph/orp Meter, an SD Logger Series meter. This meter displays and stores
More informationPCE Americas Inc. PCE Instruments UK Ltd. 711 Commerce Way Units 12/13, Southpoint Business Park Suite 8 Ensign Way Jupiter, FL 33458 Hampshire / Southampton USA United Kingdom, SO31 4RF Phone: 561-320-9162
More informationHand-held thermometer Model CTH7000
Calibration technology Hand-held thermometer Model CTH7000 WIKA data sheet CT 55.50 Applications Precision thermometer for very accurate temperature measurements in a range of -200... +962 C Reference
More informationSHIMPO INSTRUMENTS. FG-7000T Digital Torque Gauge Operation Manual
FG-7000T Digital Torque Gauge Operation Manual SHIMPO INSTRUMENTS Operators should wear protection such as a mask and gloves in case pieces or components break away from the unit under test. Whether the
More informationVibration-Resistant Weighing Indicator
Vibration-Resistant Weighing Indicator Powerful vibration-cancelling function (High Performance Digital Filter) High speed sampling (100 times/second)/high accuracy Circuits equipped with powerful noise
More informationMulti-Function Smart Indicator User Manual
Multi-Function Smart Indicator User Manual EC30006 Content 1 Notice... 2 2 Specification... 2 3 Main parameter... 3 4 How to fix... 3 5 Port... 4 6 On/Off... 4 7 Charging... 4 8 Display... 5 9 Screen keypad...
More informationOPERATION MANUAL. SD card real time datalogger, RS232/USB PRESSURE METER. Model : PS-9303SD. Your purchase of this PRESSURE METER with
SD card real time datalogger, RS232/USB PRESSURE METER Model : PS-9303SD Your purchase of this PRESSURE METER with S D C A R D DATALOGGER marks a step forward for you into the field of precision measurement.
More informationDatalogging Hygro-Thermometer
USER GUIDE Datalogging Hygro-Thermometer Model SD500 Extech SD500 Humidity Temperature Datalogger Introduction Congratulations on your purchase of the Extech SD500 Temperature/Humidity Datalogger. This
More informationUser's Guide. Barometric Pressure / Humidity and Temperature Datalogger Model SD700
User's Guide Barometric Pressure / Humidity and Temperature Datalogger Model SD700 Introduction Congratulations on your purchase of the Extech SD700 Humidity/Barometric Pressure/Temperature Datalogger.
More information12-Channel Thermocouple Datalogger
User Manual 12-Channel Thermocouple Datalogger Model TM500 Additional User Manual Translations available at www.extech.com Introduction Congratulations on your purchase of the Extech TM500 Thermometer,
More informationSound Analyser Real Time 1/1 & 1/3 Octave band Analysis
ISO-TECH Sound Analyser Real Time 1/1 & 1/3 Octave band Analysis SLA-1358 INSTRUCTION MANUAL L CONTENTS Title Page I. SAFETY INFORMATION...1 II. GENERAL INFORMATION & FEATURES...2 III. SPECIFICATIONS...2
More informationFG-3000R Digital Force Gauge Operation Manual
FG-3000R Digital Force Gauge Operation Manual Operators should wear protection such as a mask and gloves in case pieces or components break away from the unit under test. Whether the unit is ON or OFF,
More informationSpecification for temperature sensor calibration setup
1. Item description Automated Temperature calibration setup made of: A. High accuracy temperature bath with internal and external reference probe, multiple sensors insert kits, carry case and other accessories.
More informationThe IQ300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.
IQ300 Wall Mount Load Cell Indicator Data sheet English 1.01 Introduction The IQ300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications. The high
More informationAC/DC MAGNETIC METER
G ( Gauss), mt ( milli Tesla ) SD card real time data logger AC/DC MAGNETIC METER Model : MG-3003SD Your purchase of this AC/DC MAGNETIC METER with SD CARD DATA LOGGER marks a step forward for you into
More informationUser Manual. Heavy Duty Differential Pressure Manometer. Model SDL720. Additional User Manual Translations available at
User Manual Heavy Duty Differential Pressure Manometer Model SDL720 Additional User Manual Translations available at www.extech.com Introduction Congratulations on your purchase of the Extech SDL720 Pressure
More informationTRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features
TRACKER 240 SERIES Load Cell and Weighing Indicators A Precision Measurement Instrument with Outstanding Features TRACKER 240 SERIES INDICATORS Ratiometric Measurement Tare and Auto Transducer Excitation
More informationIts 16-bit ADC makes ilog data loggers well suited for science and laboratory applications where precise and accurate measurements are critical.
407 15216 North Bluff Road White Rock, BC Canada V4B 0A7 Phone: 604.424.9092 Toll Free: 1.877.352.9158 Fax: 1.877.453.0658 Email: info@microedgeinstruments.com Web: www.microedgeinstruments.com ilog Strain
More informationAC/DC MAGNETIC METER OPERATION MANUAL. Model : PCE-MFM G ( Gauss), mt ( milli Tesla ), USB/RS232. Your purchase of this
G ( Gauss), mt ( milli Tesla ), USB/RS232 AC/DC MAGNETIC METER Model : PCE-MFM 3000 Your purchase of this AC/DC MAGNETIC METER marks a step forward for you into the field of precision measurement. Although
More informationVIBRATION METER Model : VB-8213
Acceleration/Velocity/Displacement RMS/Peak/Max. Hold, Metric & Imperial unit VIBRATION METER Model : VB-8213 Your purchase of this VIBRATION METER marks a step forward for you into the field of precision
More informationALMEMO 202 ALMEMO professional measuring instrument, latest V7 generation with data logger function. ALMEMO V7 Measuring Instrument
ALMEMO V7 Measuring Instrument ALMEMO 202 ALMEMO professional measuring instrument, latest V7 generation with data logger function. Two measuring inputs for all digital ALMEMO D7 sensors. Special functions
More informationPrecision thermometer Model CTR5000
Calibration technology Precision thermometer Model CTR5000 WIKA data sheet CT 60.20 Applications Precision thermometer for very accurate temperature measurements in a range of -200... +962 C Reference
More informationBenchtop Multi-parameter Water Quality Meter
LMPWM-A Series Benchtop multi-parameter water quality meter LMPWM-A series is comes with different measurement modes for quality and testing of water on different parameters. It measures ph, Conductivity,
More informationSINGLE-CHANNEL PROCESS CONTROLLERS & TEMP. DISPLAYS D3820/D3830 Series
The Digitec Series D3800 Panel Meters offer many features and performance capabilities to suit a wide range of industrial applications. The D3820 and D3830 are available in the ranges of 4-20mA, 0-10 VDC,
More informationUSER GUIDE. 3 Channel DC Current Datalogger Model SD900
USER GUIDE 3 Channel DC Current Datalogger Model SD900 Table of Contents 1. INTRODUCTION 3 2. DESCRIPTIONS 4 3. OPERATION 5 Power 5 Connecting Current Cables 5 Datalogging 5 Time/Date/Sample Rate Check
More informationDX4085 Z-Meter Tester
DX4085 Z-Meter Tester AC Resistance ( ACR ) Measurement Figure-of-Merit ( Z ) Measurement Time Constant ( t ) Measurement dtmax estimations (for single-stage TECs) External TEC Clips USB Interface for
More informationFG-3000 Digital Force Gauge Operation Manual
FG-3000 Digital Force Gauge Operation Manual Operators should wear protection such as a mask and gloves in case pieces or components break away from the unit under test. Whether the unit is ON or OFF,
More informationPCD-400A/430A. Sensor Interface. Carrier Wave Type Compact and Moderate Prices. Data Recorders/Analyzers MEASURING INSTRUMENTS
3-77 Sensor Interface 3-77 PCD-400A Carrier Wave Type Compact and Moderate Prices Easy sensor connection using various types of input adapters Connects to PC using USB interface Measurement using 1 unit
More informationMulti-functional precision thermometer CTR3000
Calibration technology Multi-functional precision thermometer CTR3000 WIKA data sheet CT 60.15 Applications Pharmaceutical industry Industry (laboratory, workshop and production) Temperature sensor and
More informationHygro-Thermometer / Datalogger
USER GUIDE Hygro-Thermometer / Datalogger Model SDL500 Introduction Congratulations on your purchase of the Extech SDL500 Hygro-Thermometer, an SD Logger Series meter. This meter displays and stores Temperature
More information1. Introduction 2. Specifications 3. Symbol Definition and Button Location 4. Operation Instructions 5. Temperature Measurement 6.
CONTENTS TITLE PAGE 1. Introduction.. 1 2. Specifications... 1 3. Symbol Definition and Button Location... 2 4. Operation Instructions.... 3 4.1 Power-Up...3 4.2 Connection of the Temperature Probe...
More informationTES-1358 INSTRUCTION MANUAL
Sound Analyzer Real Time 1/1 & 1/3 Octave band Analysis TES-1358 INSTRUCTION MANUAL FAST L A W 75.2 100 90 80 70 60 50 40 30 Hz 31.5 8k L W 125 500 2k [ 1 / 3 OCT ] 01 / 07 / 27 14:26:39 TES ELECTRICAL
More informationWARNING: Do not use the thermometer/data logger before you read the users manual and the following instructions.
55 This unit passes the following tests EN 61326-1:2006 (CISPR11,IEC/EN 61000-3-2:2006, IEC/EN 61000-3-3: 1995+A1 :2001+A2:2005 IEC/EN 61000-4-2/-3/-5/-6/-11) WARNING: Do not use the thermometer/data logger
More informationAM3 Humidity. Temperature. Dew Point Indicator INSTRUCTION MANUAL
AM3 Humidity. Temperature. Dew Point Indicator INSTRUCTION MANUAL CONTENTS 1. Battery Operation... 3 2. Operation with a Rechargeable Battery... 3 3. Humidity and Temperature Probe (Probe Input 1)... 3
More informationOPERATION MANUAL. SD card real time datalogger HUMIDITY/TEMP. MONITOR. Model : MHT-381SD
SD card real time datalogger HUMIDITY/TEMP. MONITOR Model : MHT-381SD Your purchase of this HUMIDITY/TEMP. MONITOR with SD CARD DATALOGGER marks a step forward for you into the field of precision measurement.
More information12 channels TEMPERATURE RECORDER Model : BTM-4208SD
SD Card real time data recorder 12 channels TEMPERATURE RECORDER Model : BTM-4208SD Your purchase of this 12 c h a n n e l s T E M P E R A T U R E RECORDER with SD CARD DATALOGGER marks a step forward
More informationTechnical Parameter... 4 Installation and Connection... 5
2 CONTENTS Technical Parameter... 4 Installation and Connection... 5 1. Indicator Diagram... 5 2. Loadcell Connection... 6 3. Serial Communication interface and Scoreboard... 7 Operation Instruction...
More information1450 First Ave. Page 1 of 11 Chippewa Falls, WI (800) or (715) Fax: (715)
1450 First Ave. Page 1 of 11 Model DHM200 User Manual 1450 First Ave. Page 2 of 11 Warranty This product is fully warranted against defective materials and/or workmanship for a period of one year after
More information3 Channel Datalogging Thermometer
USER MANUAL 3 Channel Datalogging Thermometer Model SD200 Introduction Congratulations on your purchase of the Extech SD200 3-Channel Temperature Datalogger. This meter displays and stores temperature
More informationAfter unpacking, check the GL820's Exterior to make sure that there are crack or other damage before use.
PRESSURE LOAD TORQUE POSITION ROTARY ANGLE TILT ACCELERATION VIBRATION RATE SIGNAL CONDITIONER DATALOGGER midi LOGGER GL820 Quick Start Guide GL820-UM-851 Thank you for choose the midi LOGGER GL820. This
More informationPennsylvania Scale Company Model 400B Battery Powered Digital Indicator Operation & Calibration Manual
Pennsylvania Scale Company Model 400B Battery Powered Digital Indicator Operation & Calibration Manual Pennsylvania Scale Company 1042 New Holland Avenue Lancaster PA 17601 For online interactive tech
More informationThermometer T12. Precision Multichannel Thermometer System. Typical applications: REFLECTING YOUR STANDARDS
Precision Multichannel Thermometer System Twelve channel temperature measurement High precision, stability and repeatability Internal reference resistors PC software for system control and data acquisition
More informationOPERATION MANUAL. ph/mv SD card real time data logger ph METER. Model : PH-230SD
ph/mv SD card real time data logger ph METER Model : PH-230SD Your purchase of this ph METER with SD CARD DATA LOGGER marks a step forward for you into the field of precision measurement. Although this
More informationWide Bandwidth Strain Gage Input 3B18 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM
Wide Bandwidth Strain Gage Input 3B18 FEATURES Wideband (20 khz) single-channel signal conditioning module. Module Bandwidth is user-selectable between 20 khz and 100Hz, with user-supplied filter caps
More informationMobilControl MC 4000 OWNER S MANUAL
MobilControl MC 4000 Hand Held Service instrument with data logger for pressure, min / max & differential pressure, temperature, flow / rpm and hydraulic horsepower OWNER S MANUAL 20 7 TERMINALS 7.1 Plugs
More informationMeasurement Systems Datascan Installation and User Guide
Measurement Systems Datascan Installation and User Guide Supplied By Contents Contents 1. INTRODUCTION... 1 1.1 GENERAL... 1 1.2 DATASCAN MODULE RANGE... 1 1.2.1 Measurement Processors... 1 1.2.2 Analog
More informationPrecision hand-held pressure indicator Model CPH6400
Calibration technology Precision hand-held pressure indicator Model CPH6400 WIKA data sheet CT 14.01 Applications Calibration service companies and service industry Measurement and control laboratories
More informationPRESSURE METER OPERATION MANUAL. Model : PS-9302
PRESSURE METER Model : PS-9302 Your purchase of this PRESSURE METER marks a step forward for you into the field of precision measurement. Although this PRESSURE METER is a complex and delicate instrument,
More information600 g x 0.02 g DIGITAL BALANCE
600 g x 0.02 g DIGITAL BALANCE Model : GM-600P Your purchase of this DIGITAL BALANCE marks a step forward for you into the field of precision measurement. Although this DIGITAL BALANCE is a complex and
More informationData Sheet Type RS420. Series 420 Specification Rotor / Stator Non-contact Rotary Torque Transducers
Type RS420 Datum Electronics has further extended its standard range of torque transducers to cater for higher rotary speeds and an increased number of torque ranges. The 420 Series torque transducers
More information4-Channel Thermometer / Datalogger
User's Guide 4-Channel Thermometer / Datalogger RTD and Thermocouple Inputs Model SDL200 Introduction Congratulations on your purchase of the Extech SDL200 Thermometer, an SD Logger Series meter. This
More informationTRACKER 220 SERIES. Digital Panel Indicators. A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement
TRACKER 220 SERIES Digital Panel Indicators A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement TRACKER 220 SERIES INDICATORS Universal Input Analogue Output
More informationGSV-1A4 M12/2 M12/2. Highlights
GSV-1A4 M12/2 M12/2 Highlights Input sensitivity: 2mV/V; 4mV/V, 2 mv/v, 1mV/V, 0.5mV/V configurable via jumpers Output signals ±10V AND 12mA+-8mA on 15 pin Sub-D Integrated half and quarter bridge completion
More informationBusiness. Republic of SEWHACNM to the world beyond. 1 2 Industrial Automation
Business 1 2 Industrial Automation Indicator - Simple Digital Weighing Indicator - Universal Weighing Indicator - Packaging Control Indicator - Multiple Mixture Control Indicator - DIN Size Digital Weighing
More informationCảm ơn các bạn đã tham khảo tài liệu cân điện tử từ CÂN ĐIỆN TỬ GIA PHÁT!
Đ/c1: 534 Điện Biên Phủ, Phường 21, Quận Bình Thạnh, Tp Hồ Chí Minh Đ/c2: 42 Hùng Vương, Phường Xuân Bình, Thị xã Long Khánh, Tỉnh Đồng Nai Website: www.cangiaphat.com Email: giaphat.scale@gmail.com Zalo,
More informationThe Tracker 220 Series A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement
Acquisition Measurement Control The Tracker 220 Series A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement TRACKER 220 SERIES INDICATORS Universal Input
More informationClamp-On Digital Multimeters
Clamp-On Digital Multimeters GS-Mark EN61010-1 Approval Voltage Category III 600 V, Pollution Degree II AC/DC Current Clamp Highly Accurate 1999, 2500, 3999, 4300 Counts Resolution MAX, Data Hold, PEAK,
More informationDCS Series. Digital Counting Scale. Setup Manual
DCS Series Digital Counting Scale Setup Manual Revision 1.1 February 12, 1997 1996-1997 Transcell Technology, Inc. Contents subject to change without notice. Transcell Technology, Inc. 975 Deerfield Parkway
More informationWTX110. Legal-for-trade industrial weighing terminal. Special features. Data sheet
WTX110 Legal-for-trade industrial weighing terminal Special features - Up to 8 SG load cells can be connected (350 ohms) - Stainless steel housing shapes for desktop and wall mounting or control cabinet
More informationOPERATION MANUAL. SD card real time datalogger, RS232/USB VIBRATION METER. Model : VB-8206SD
SD card real time datalogger, RS232/USB VIBRATION METER Model : VB-8206SD Your purchase of this VIBRATION METER with SD CARD DATALOGGER marks a step forward for you into the field of precision measurement.
More information-Direct.com FG-3000 Digital Force Gauge Operation Manual
FG-3000 Digital Force Gauge Operation Manual Operators should wear protection such as a mask and gloves in case pieces or components break away from the unit under test. Whether the unit is ON or OFF,
More informationUser's Guide. 3 Channel Datalogging Thermometer Model SD200
User's Guide 3 Channel Datalogging Thermometer Model SD200 Introduction Congratulations on your purchase of the Extech SD200 3-Channel Temperature Datalogger. This meter displays and stores temperature
More informationStrain gauge Measuring Amplifier GSV-1A8. Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB
Strain gauge Measuring Amplifier GSV-A8 Instruction manual GSV-A8, GSV-A8USB, GSV-A6USB GSV-A8USB SubD5 (front side) GSV-A8USB M2 (front side) GSV-A6USB (rear side) GSV-A8USB K6D (front side) Version:
More informationPanel Indicators. NEW 4~20mA Panel Display. Process Indicators INTECH INSTRUMENTS.
The LPI-LCD-6-4~20mA panel display is ideal for displaying a variety of process variables, and is easy to scale to your required engineering units. LPI-LCD-6 4~20mA Panel Display. Loop powered. Loop powered
More informationTPM Operation Manual
Revision 1.1 July 17, 2017 TPM Operation Manual Parameter setting, monitoring and auto data memory for MDC & ADC www.mountztorque.com - 1080 N 11th St - San Jose CA 95112-408.292.2214 1 Index 1. Main feature
More informationThe IQ240 panel mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.
IQ240 Panel Mount Load Cell Indicator Data sheet English 1.01 Introduction The IQ240 panel mount load cell indicator is a precision digital indicator for load cell and strain gauge applications. The high
More informationPUE C/31 measuring indicators PUE C/31H measuring indicators PUE C/31H/EX measuring indicators PUE C/41H measuring indicator...
CONTENTS PUE C/31 measuring indicators..................................... 3 PUE C/31H measuring indicators.................................... 4 PUE C/31H/EX measuring indicators..................................
More informationHand-held thermometer Model CTH7000
Calibration technology Hand-held thermometer Model CTH7000 WIKA data sheet CT 55.50 for further approvals see page 2 Applications Precision thermometer for very accurate temperature measurements in a range
More informationUSER INSTRUCTION MANUAL FOR LOADCELL TRANSMITTER MODEL TDC/I/0550 (SOFTWARE: VER2A) INDEX
USER INSTRUCTION MANUAL FOR LOADCELL TRANSMITTER MODEL TDC/I/0550 (SOFTWARE: VER2A) INDEX DOCUMENT NO: TDC 0550 MANUAL - 2 1.0) INTRODUCTION. PAGE 2 1.1) ABOUT THIS MANUAL. PAGE 2 1.2) INTRODUCTION. PAGE
More informationPS-IN202 Weighing Indicator User Manual
PS-IN202 Weighing Indicator User Manual Version 2015.05 Contents FRONT AND REAR VIEW OF THE INDICATOR CHAPTER 1 CONNECTIONS 1.1 WHAT'S IN THE BOX 1.2 CONNECTING TO THE WEIGH PLATFORM 1.3 CONNECTION TO
More information