Installation and Operation Manual DPC1

Size: px
Start display at page:

Download "Installation and Operation Manual DPC1"

Transcription

1 Installation and Operation Manual DPC1 BIA-DPC1 rev 5 Page 1

2 TABLE OF CONTENTS Page QUICK GUIDE DRAINAGE PUMPS FLOATS CONNECTED TO PANEL 4-5 QUICK GUIDE DRAINAGE PUMPS FLOATS CONNECTED TO PUMPS 6-7 QUICK GUIDE PRESSURE BOOSTING 8-9 QUICK GUIDE TRANSFER QUICK GUIDE HOT WATER CIRCULATION INTRODUCTION 1.1 Applications Technical parameters and features Meanings of the icons shown on the LCD GENERAL 2.1 Electrical connection to the power supply and pump Connections for pump over temperature protection (where supplied) Installing float switches and probes INSTALLATION DRAINAGE 3.1 Function switch setting Diagrams for drainage by liquid level through float switches or probes INSTALLATION DRAINAGE WITH AUTOMATIC PUMPS 4.1 Function switch setting Diagram for drainage by liquid level 26 Cont... BIA-DPC1 rev 5 Page 2

3 TABLE OF CONTENTS cont. 5.0 INSTALLATION BOOSTING 5.1 Function switch setting Diagrams for boosting by liquid level through float switches or probes INSTALLATION TRANSFER 6.1 Function switch setting Diagrams for transfer by liquid level through float switches or probes INSTALLATION TRANSFER HOT WATER CIRCULATION 7.1 Function switch setting Diagrams for transfer by liquid level through float switches or probes OPERATION 8.1 Parameter calibration and erasing Switching to AUTO mode Switching to MANUAL mode Alarm Test and MUTE Pump protection Last five failure record Pump accumulated running time Pump disable COMMUNICATION LINK Basic Function Special application Technical parameters TROUBLE SHOOTING GUIDE 44 BIA-DPC1 rev 5 Page 3

4 DPC1 QUICK GUIDE DRAINAGE PUMPS FLOATS CONNECTED TO PANEL SET THE DIP SWITCHES ON THE INSIDE OF THE DOOR DO NOT REMOVE BRIDGES BETWEEN TERMINALS 9&11 AND 10&12 BIA-DPC1 rev 5 Page 4

5 DPC1 QUICK GUIDE DRAINAGE PUMPS FLOATS CONNECTED TO PANEL CALIBRATION TURN MCB ON SWITCH TO MANUAL PRESS MODE AND STORE AT THE SAME TIME FOR 5 SEC CALIBRATE PUMP A PRESS ASTART THEN AFTER PUMP RUNNING FOR 10 SECONDS PRESS STORE CALIBRATE PUMP B PRESS BSTART THEN AFTER PUMP RUNNING FOR 10 SECONDS PRESS STORE SWITCH TO AUTO PRESS MODE BIA-DPC1 rev 5 Page 5

6 DPC1 QUICK GUIDE DRAINAGE PUMPS FLOATS CONNECTED TO PUMPS SET THE DIP SWITCHES ON THE INSIDE OF THE DOOR INSTALL EXTRA JUMPERS DO NOT REMOVE BRIDGES BETWEEN TERMINALS 9&11 AND 10&12 BIA-DPC1 rev 5 Page 6

7 DPC1 QUICK GUIDE DRAINAGE PUMPS FLOATS CONNECTED TO PUMPS CALIBRATION TURN MCB ON SWITCH TO MANUAL PRESS MODE AND STORE AT THE SAME TIME FOR 5 SEC CALIBRATE PUMP A PRESS ASTART THEN AFTER PUMP RUNNING FOR 10 SECONDS PRESS STORE CALIBRATE PUMP B PRESS BSTART THEN AFTER PUMP RUNNING FOR 10 SECONDS PRESS STORE SWITCH TO AUTO PRESS MODE BIA-DPC1 rev 5 Page 7

8 DPC1 QUICK GUIDE PRESSURE BOOSTING SET THE DIP SWITCHES ON THE INSIDE OF THE DOOR DO NOT REMOVE BRIDGES BETWEEN TERMINALS 9&11 AND 10&12 INSTALL EXTRA JUMPER BIA-DPC1 rev 5 Page 8

9 DPC1 QUICK GUIDE PRESSURE BOOSTING CALIBRATION TURN MCB ON SWITCH TO MANUAL PRESS MODE AND STORE AT THE SAME TIME FOR 5 SEC CALIBRATE PUMP A PRESS ASTART THEN AFTER PUMP RUNNING FOR 10 SECONDS PRESS STORE CALIBRATE PUMP B PRESS BSTART THEN AFTER PUMP RUNNING FOR 10 SECONDS PRESS STORE SWITCH TO AUTO PRESS MODE BIA-DPC1 rev 5 Page 9

10 DPC1 QUICK GUIDE TRANSFER SET THE DIP SWITCHES ON THE INSIDE OF THE DOOR MOVE JUMPER FROM 3&5 TO 4&6 DO NOT REMOVE BRIDGES BETWEEN TERMINALS 9&11 AND 10&12 BIA-DPC1 rev 5 Page 10

11 DPC1 QUICK GUIDE TRANSFER CALIBRATION TURN MCB ON SWITCH TO MANUAL PRESS MODE AND STORE AT THE SAME TIME FOR 5 SEC CALIBRATE PUMP A PRESS ASTART THEN AFTER PUMP RUNNING FOR 10 SECONDS PRESS STORE CALIBRATE PUMP B PRESS BSTART THEN AFTER PUMP RUNNING FOR 10 SECONDS PRESS STORE SWITCH TO AUTO PRESS MODE BIA-DPC1 rev 5 Page 11

12 DPC1 QUICK GUIDE HOT WATER CIRCULATION SET THE DIP SWITCHES ON THE INSIDE OF THE DOOR DO NOT REMOVE BRIDGES BETWEEN TERMINALS 9&11 AND 10&12 BIA-DPC1 rev 5 Page 12

13 DPC1 QUICK GUIDE HOT WATER CIRCULATION CALIBRATION TURN MCB ON SWITCH TO MANUAL PRESS MODE AND STORE AT THE SAME TIME FOR 5 SEC CALIBRATE PUMP A PRESS ASTART THEN AFTER PUMP RUNNING FOR 10 SECONDS PRESS STORE CALIBRATE PUMP B PRESS BSTART THEN AFTER PUMP RUNNING FOR 10 SECONDS PRESS STORE SWITCH TO AUTO PRESS MODE BIA-DPC1 rev 5 Page 13

14 Conventions used in this manual. In the manual the following symbols will be used: Generic danger. Failure to comply with the safety regulations that follow can irreparably damage the controller or equipment. Electric shock risk. Failure to comply with the safety regulations that follow can cause death or serious injury. WARNINGS Read this manual carefully before any operation. Please keep this manual for future use. WARNING!! 1. Installation must be carried out by a suitably qualified electrician. 2. Before carrying out any installation or maintenance operation, controller must be disconnected from the power supply. 3. Do not open the cover during running the controller. 4. Do not splash water or other liquid over the controller. 5. Do not allow children or infirm persons to operate the control. 6. Qualified electrician is to correctly size and install circuit breakers to protect power supply. CAUTION!! 1. The electrical and hydraulic connections must be carried out by competent, skilled, qualified personnel. 2. Never connect AC power to the output terminals. 3. Ensure the pump and controller characteristics match. 4. Do not install the controller in the following conditions: a. Vibration and mechanical shock. b. Corrosive gasses and liquids. c. Extreme heat and cold, operating range -25 o C o C. d. Salt mist corrosion. e. Rain and moisture. f. Flammable materials, solvents. BIA-DPC1 rev 5 Page 14

15 1.0 Introduction Thank you for choosing a Bianco Icon Series Intelligent Pump Controller. The Intelligent Pump Controller model is an easy to use, programmable controlling and protection device for direct start, single phase pumps with output power from 0.37kW 2.2kW. The Controller has many operation modes by adopting different electrical installations. Important features that distinguish the Bianco Icon Series Intelligent Pump Controllers from some other controllers are the push button calibration of overload and ability for dry run protection without float switches or probes. 1.1 Applications The Controller is useful in all cases where there is the need to control and protect single pump installations managing the automatic operation by a variety of switching methods. Typical usage scenarios include: Stormwater Sewage Booster sets Rainwater reuse Irrigation Water supply 1.2 Technical parameters and features Built in function switch for o Drainage by liquid level control through float switches or probes o Boosting water supply by pressure control through pressure switch and tank o Transfer water by liquid level control through float switches and probes Dry run protection without float switches or probes Auto/Manual switch Dynamic LCD displaying pump running state Protect the pump against many faults Push button calibration Pump accumulative running time Last five fault record RS485 communication Starts and stops the pump in accordance with liquid levels and pressure settings BIA-DPC1 rev 5 Page 15

16 The following chart shows main technical parameters for the Controller DPC1 Main technical characteristic Control characteristic Control method Liquid level control characteristic Pressure control characteristic Main technical data Rated output power Rated input voltage Trip response time of overload Trip response time of open phase Trip response time of short circuit Trip response time of under/over voltage Trip response time of dry run Recovery time of over load Recovery time of under/over voltage Recovery time of dry run Trip voltage of over voltage Trip voltage of under voltage Liquid level transfer distance maximum Protection functions Main installation data Working temperature Working humidity Degree of protection Install position Unit dimensions (L x W x H) RS485 technical data Physical interface Baud rate Protocol type Double liquid level control pressure control Manual/Auto pulse electrode probe and float switch pressure switch and pressure tank kw ( hp) 240V 5 sec - 5 min < 2 sec < 0.1 sec < 5 sec 6 sec 30 min 5 min 30 min 115% of rated input voltage 80% of rated input voltage 1000m Dry run Over load Transient voltage Under voltage Over voltage Pump stalled Short circuit -25 to +55 deg C 20% to 90% Relative Humidity, non-condensing IP54 Vertical 30.2 x 24.0 x 12.0 cm RS485 Bus Interface: asynchronous semi duplex 1200,2400,4800,9600 bps (default 9600bps) MODBUS protocol (RTU) BIA-DPC1 rev 5 Page 16

17 1.3 Meanings of the icons shown on the LCD. Icon Meaning / Description pump parameter configuration icon, when this icon appears, pump control box is parameter setting time displaying icon, when this icon appears, it means pump control box is displaying some parameter of time, eg: pump accumulated running time (unit: hour); counting down etc pump fault icon, when this icon appears, it means pump control box is displaying some fault information network connection error icon, when this icon appears, it means there is no network connections or network connection error between pump control box and SC(slave controller) or computer V M S H network normal connection icon, when this icon appears, it means the network connection between pump control box and SC (slave controller) or computer is normal voltage minute second hour % percent A ampere pump running pump stopped low pressure or lack of pressure in the pipeline or pressure tank high pressure or full of pressure in the pipeline or pressure tank pump A pump B (for dual pump controllers) BIA-DPC1 rev 5 Page 17

18 2.0 GENERAL 2.1 Electrical connection to the power supply and pump Main Circuit Breaker DANGER. Electric shock risk. Before carrying out any installation or maintenance operation, the control panel should be disconnected from the power supply and one should wait at least 2 minutes before opening the control panel. Never connect AC power to output L and N terminals. Ensure the motor, controller and power specifications match. The electrical and hydraulic connections must be carried out by competent, skilled, qualified personnel. Other terminals. Terminals 7 and 8 Terminals 15 and 16 MODBUS communication to Slave Controller or BMS N.O. close on fault Terminals 9 and 11 and 10 and 12 for connection to motor thermal protection (microtherms) where available. If not available leave jumper wires in. BIA-DPC1 rev 5 Page 18

19 2.2 Connections for pump over temperature protection (where supplied with pump). Jumper Leads Note: to realize the pump motor winding over temperature protection, it requires that there must be over-temperature switches embedded in the pump motor winding (microtherms as fitted to Zenit 3ph pumps 2.2 kw or greater). To utilise the pump s over temperature protection connect the pump s microtherm leads to terminals 9 and 11, 10 and 12 and remove the jumper. Note: if the pump is without over temperature switch, please use jumper to connect terminals 9 and 11, 10 and Installing float switches and probes. Float switch installation. Do not encase sensor leads, float switches or signal cables in metal pipes. Use PVC or PE tubing. Liquid probe installation. In event of high risk of electrical storms (lightning) or when liquid medium in sump, well or tank is very dirty, it is recommended to use float switches. BIA-DPC1 rev 5 Page 19

20 3.0 INSTALLATION DRAINAGE PUMPS FLOATS CONNECTED TO PANEL 3.1 Function switch setting - DRAINAGE Installers can set the function switch to meet different applications. Before setting the function switch, the control panel should be disconnected from the power supply. After completing the setting, apply power to the control panel and observe the application sign displayed on the LCD conforming to the DRAINAGE symbol. MCB DRAINAGE SETTING SWITCHES DOWN DRAINAGE SYMBOL BIA-DPC1 rev 5 Page 20

21 3.2 Electrical connections for DRAINAGE PUMPS FLOATS CONNECTED TO PANEL Drainage by liquid level control through float switches or probes Note: for 4 float switch installation connect float switch A (pump off) to terminals 1 and 3, float switch B (1 st pump on) to terminals 1 and 5, float switch C (2 nd pump on) to terminals 2 and 4 and float switch D (alarm) to terminals 2 and 6. BIA-DPC1 rev 5 Page 21

22 3.2.2 Drainage by liquid level control through float switches or probes (cont) Note: for 4 float switch installation connect float switch A (pump off) to terminals 1 and 3, float switch B (1 st pump on) to terminals 1 and 5, float switch C (2 nd pump on) to terminals 2 and 4 and float switch D (alarm) to terminals 2 and 6. BIA-DPC1 rev 5 Page 22

23 3.2.3 Drainage by liquid level control through float switches or probes (cont) BIA-DPC1 rev 5 Page 23

24 Stop condition Liquid level in the sump is reaches probe 2, (float switch A down) the control panel will stop the pump. Start condition Liquid level in the sump reaches probe 3, (float switch A up) the control panel will run a pump. Control panel will alternate the pumps when the liquid level varies between probe 2 and probe 3 (float switch A up and down). 2 nd pump start condition Liquid level in the sump reaches probe 4, (float switch B up) the control panel will run the second pump. Pumps run simultaneously until liquid level reaches probe 2, (float switches A and B down). Alarm condition While pumping, if the liquid level rises in the sump to probe 5, (float switch C up), the control panel will sound the alarm to warn the user to take further action. Meanings of the messages & graphic shown on the LCD screen BIA-DPC1 rev 5 Page 24

25 4.0 INSTALLATION DRAINAGE PUMPS FLOATS CONNECTED TO PUMPS 4.1 Function switch setting DRAINAGE WITH AUTOMATIC PUMPS Installers can set the function switch to meet different applications. Before setting the function switch, the control panel should be disconnected from the power supply. After completing the setting, apply power to the control panel and observe the application sign displayed on the LCD conforming to the DRAINAGE symbol. MCB DRAINAGE SETTING FOR AUTOMATIC PUMPS DRAINAGE SYMBOL BIA-DPC1 rev 5 Page 25

26 4.2 Electrical connections DRAINAGE PUMPS FLOATS CONNECTED TO PUMPS Drainage by liquid level control. Note: for drainage with automatic pumps, floats A & B are not used and terminals 1, 3, 5 and 2,4 are bridged. Note: for 3 wire floats use black and brown wires. Terminate blue wire with closed end connector. Alarm float C connected to terminals 2 and 6. If the system activates the high level alarm connected to the control panel the second pump will start and the alarm will activate until the high level float deactivates. If a pump fail situation is detected then the pump will switch to the second pump. Warning DRY RUN Protection not active in Drainage with Automatic Pump Mode. High Level Alarm Delay High Level Alarm delayed by 15 minutes after activation of High Level Float to allow 2 nd Pump to turn on and assist with pump out. Note, For 30 minutes after High level Alarm activated, both pumps work concurrently. BIA-DPC1 rev 5 Page 26

27 Stop condition Liquid level in the sump is below automatic pump float switch off position which will stop both pumps. Start condition The control panel alternates power supply between pumps every 240 hours. When liquid level in the sump is above the automatic pump float switch on position, the pump that is being supplied power will run. Alarm condition While pumping, if the liquid level rises in the sump to float switch C up, the control panel will start the second pump and will sound the alarm to warn the user to take further action. Meanings of the messages & graphic shown on the LCD screen BIA-DPC1 rev 5 Page 27

28 5.0 INSTALLATION - BOOSTING 5.1 Function switch setting - BOOSTING Installers can set the function switch to meet different applications. Before setting the function switch, the control panel should be disconnected from the power supply. After completing the setting, apply power to the control panel and observe the application sign displayed on the LCD conforming to the BOOSTING symbol. MCB BOOSTING SETTING SWITCHES UP BOOSTING SYMBOL BIA-DPC1 rev 5 Page 28

29 5.2 Electrical connections for BOOSTING applications Water supply by pressure control through pressure switch and tank. BIA-DPC1 rev 5 Page 29

30 5.2.2 Water supply by pressure control through pressure switch and tank (cont) BIA-DPC1 rev 5 Page 30

31 5.2.3 Water supply by pressure control through pressure switch and tank (cont) BIA-DPC1 rev 5 Page 31

32 Normal demand Pressure in the pipeline is lower than the setting of pressure switch B, control box will order single pump to run; pressure in the pipeline reaches the setting of pressure switch B, single pump stops running; control box will alternate double pumps running automatically when pressure in the pipeline varies in the range of pressure switch B Extra demand Single pump is running, pressure in the pipeline still decrease to the setting of pressure switch A, control box will order another pump to run simultaneously, till pressure in the pipeline reaches the setting of pressure switch B, double pumps will not stop running; Note: pressure switch should be N/C, close on pressure drop. Note: Pressure switch A = Low Pressure Switch, Pressure switch B = High Pressure Switch Meanings of the messages & graphic shown on the LCD screen BIA-DPC1 rev 5 Page 32

33 6.0 INSTALLATION - TRANSFER 6.1 Function switch setting - TRANSFER Installers can set the function switch to meet different applications. Before setting the function switch, the control panel should be disconnected from the power supply. After completing the setting, apply power to the control panel and observe the application sign displayed on the LCD conforming to the TRANSFER symbol. MCB TRANSFER SETTING TRANSFER SYMBOL BIA-DPC1 rev 5 Page 33

34 6.2 Electrical connections for TRANSFER applications Water supply by liquid level control through float switches or probes. BIA-DPC1 rev 5 Page 34

35 6.2.2 Water supply by liquid level control through float switches or probes (cont) BIA-DPC1 rev 5 Page 35

36 Normal demand Liquid level in the water storage tank is lower than Probe 1 # (float switch A: Down level), control box will order single pump to run; Liquid level reaches probe 4 # (float switch A: Up level), single pump stops running; control box will alternate double pumps running automatically when liquid level varies from Probe 1# & Probe 4#, (Float Switch A: Down level Up level Down level) Extra demand when single pump is running, liquid level is still decreasing to Probe 2# (Float Switch B: Down level), control box will order another pump to run simultaneously, until liquid level reaches Probe 4# (Float Switch A & B: Up level), double pumps will not stop running; Meanings of the messages & graphic shown on the LCD screen BIA-DPC1 rev 5 Page 36

37 7.0 INSTALLATION TRANSFER HOT WATER CIRCULATION 7.1 Function switch setting TRANSFER HOT WATER CIRCULATION Installers can set the function switch to meet different applications. Before setting the function switch, the control panel should be disconnected from the power supply. After completing the setting, apply power to the control panel and observe the application sign displayed on the LCD conforming to the TRANSFER symbol. MCB TRANSFER SETTING FOR HOT WATER CIRCULATION TRANSFER SYMBOL BIA-DPC1 rev 5 Page 37

38 7.2 Electrical connections for TRANSFER HOT WATER CIRCULATION applications Hot Water Circulation with or without thermostat. The control panel alternates power supply between pumps every 240 hours. A thermostat can be wired to terminals 2 and 4 for automatic operation on temperature. BIA-DPC1 rev 5 Page 38

39 8.0 OPERATION 8.1 Parameter calibration and erasing. To achieve best level of protection of the pump, it is essential that parameter calibration be done immediately after successful pump installation or pump maintenance. Setting the parameter calibration. Pump/s must be able to pump water to enable correct calibration. If pumps are calibrated without water, overload and pump stalled errors may occur later. If calibration is required without water, please contact White International for advice. Press the MODE key to switch to manual state. If the control panel is locked press MODE and STORE keys at the same time to unlock and go into manual mode. Make sure that the pump is not running and LCD screen is displaying: Press the A START key to run pump A, confirm the pump and all pipe network is in normal working state (including voltage, amps etc) with LCD screen displaying: Press the STORE button. The control panel makes a beep and a countdown starts with the LCD displaying: Control now counts down from 5 seconds. The pump stops running and parameter calibration is completed with LCD displaying: Press the B START key to repeat calibration for pump B. BIA-DPC1 rev 5 Page 39

40 Erasing former parameter. When pump is reinstalled after maintenance or a new pump is installed, user must erase the former calibration and a new calibration must be done. Erasing the parameter calibration. Press the MODE key to switch to manual state. If the control panel is locked press MODE and STORE keys at the same time to unlock and go into manual mode. Make sure the pump is not running and LCD is displaying: Press the A STOP key for 30 seconds; the control panel makes a beep sound, and the control panel recovers the default factory setting and the LCD displays: with Pump No Calibration flashing. Repeat for pump B by using the B STOP key for 30 seconds. 8.2 Switching to AUTO mode. To switch between MANUAL and AUTO mode press MODE. AUTO mode automatically locks control panel. Under auto state the control panel will run or stop the pump according to the signal from the liquid level probe or float switch. Note: under auto state, if the pump is running and user wants to stop the pump, press the MODE key to switch to manual state and the pump stops. Note: under auto state, if the input power is cut off and the recovers, the control panel will enter operating state after 10 seconds countdown Note: no matter if the control panels is under auto or manual state, if the input power is cut of and recovers again, the control panel will resume its operation in the same state as before the power being cut off. 8.3 Switching to MANUAL mode. To switch between AUTO and MANUAL model press MODE and STORE keys at the same time for 5 seconds to unlock and go into MANUAL mode. Press the START key to start the pump and the STOP to stop the pump. 8.4 Alarm Test and Mute. Under MANUAL mode and pump/s not operating press STORE for 3 seconds to test the alarm. At any time press ASTOP to mute the alarm. 8.5 Pump Protection During pump running, if dry run, overload, over voltage, etc failures occur, the control panel will immediately shut down the pump running and automatically execute a check for restarting conditions after a built in time delay has elapsed. The control panel will not recover automatically until all the abnormal situations have been cleared. If pump stalled, open phase or other serious failure has occurred, pump user must immediately check pump and motor. BIA-DPC1 rev 5 Page 40

41 8.6 Last five failure record The control panel can memorize the last five failures of pump, so it is very convenient for the users to analyse the pump running conditions. Displaying the last five failure record. Press the MODE key to switch to manual state, make sure the pump is not running and the LCD screen is displaying: Hold pressing A STOP key and press MODE key, the control panel makes a beep sound and displays pump A failure record. Press the A STOP key to quit the failure record display; Failure Icon Note: the failure displayed above is PUMP STALLED. Repeat for pump B by using B STOP key. 8.7 Pump accumulative running time The control panel can memorise how many hours of pump running, so it is very convenient for the pump user to analyse the pump running conditions and do maintenance. Displaying the pump accumulative running time. Press the MODE key to switch to manual state, make sure that the pump is not running and the LCD screen is displaying: Hold pressing the STORE key and press the A STOP key. The control panel makes a beep sound and displays the accumulative run time. BIA-DPC1 rev 5 Page 41

42 The pump has run for 23 hours. Press the A STOP key to quit the accumulative running time display. Repeat for pump B by using B STOP key. 8.8 Pump disable. To disable a pump independently, in AUTO mode press MODE and A STOP or B STOP at the same time for 2 seconds. A PUMP and MANUAL flashing means pump A is disabled. To restore the pump, in AUTO mode press MODE and A START or B START at the same time for 2 seconds. 9.0 Communication link. The control panel has communication interface, that along with the optional Slave Controller, users can realise a long distance monitoring function. This function applies to where the control panel is installed in the basement or pumping room, but users require to monitor and control the pump on the ground or in a control room. BIA-DPC1 rev 5 Page 42

43 9.1 Basic function. Slave Controller (SC) with communication interface can realize long distance monitoring. In the control room, users can realize all the functions of the master control panel through the SC, except parameter calibration and adjusting. 9.2 Special application. As adopting communication interface, the wire communication distance is less than 1200 metres. For those installation environments which require a longer distance communication, i.e., mine, water tower, across railway road and bridge etc., users can adopt RS485 extender, wireless communication or GSM. Please contact the manufacturer for more information. 9.3 Technical parameters. The following chart shows main technical parameters of communication between the control panel and the slave controller. Main technical data Physical interface RS485 Bus Interface: asynchronous semi duplex Data format 1 start bit, 8 data bit, 1 stop bit, no verify 1 start bit, 8 data bit, 2 stop bit, no verify Default: 1 start bit, 8 data bit, 1 stop bit, no verify Baud rate 1200,2400,4800,9600 bps (default 9600bps) Communication address Setting range of controller address: : broadcast address, host computer broadcasting, slave machine response forbidden Protocol type MODBUS protocol (RTU) Rated input voltage for SC AC 240V/50Hz, single phase Main installation data Wire communication distance 1200 metres max by shield twisted pair cable (STP) for RS485 & CAN 5000 metres max by STP and RS485 extender STP STP-120U one pair 20AWG for RS485 & CAN RS485 extender 5000 metres (9600bps) BIA-DPC1 rev 5 Page 43

44 10.0 Trouble shooting guide Fault Message Possible Cause Solutions flashing of UNDER V the real running voltage is lower than the report low line voltage to the power calibrated voltage, pump is in under voltage supply company protection state Control will attempt to restart the pump every 5 min until line voltage is restored to normal flashing of OVER V the real running voltage is higher than the report low line voltage to the power flashing of OVER LOAD calibrated voltage, pump is in over voltage protection state the real running ampere is higher than the calibrated running ampere, pump is in over load protection state pump damaged supply company Control will attempt to restart the pump every 5 min until line voltage is restored to normal Control will attempt to restart the pump every 30 min until running ampere is restored to normal inspect pump flashing of parameter calibration not completed refer to parameter calibration setting PUMP NO CALIBRATION flashing of DRY RUN liquid level in the well / sump is below the pump intake, pump stops running Control will attempt to restart the pump every 30 min until liquid level is above the pump intake flashing of pump running amps exceeded cut off power supply and repair or PUMP STALLED normal rum amps by more than 200% replace pump flashing of pump starts more than 5 times per Check pressure tank precharge REPEATED START minute Check pressure tank bladder Check pressure switch settings Check pressure switch for defects no communication link between SC / computer and Control connect the Control to SC / computer to realize long distance monitoring BIA-DPC1 rev 5 Page 44

45 BIA-DPC1 rev 5 Page 45

46 BIA-DPC1 rev 5 Page 46

Installation and Operation Manual SPC1

Installation and Operation Manual SPC1 Installation and Operation Manual SPC1 BIA-SPC1 rev 5 Page 1 TABLE OF CONTENTS Page QUICK GUIDE DRAINAGE PUMP FLOATS CONNECTED TO PANEL 4-5 QUICK GUIDE DRAINAGE PUMP FLOAT CONNECTED TO PUMP 6-7 QUICK GUIDE

More information

icon Series Controls

icon Series Controls icon Series Controls icon Series Controls Introducing the Bianco icon range of intelligent controllers. The icon range of intelligent controllers are suitable for installation in various Industrial and

More information

ICON SERIES IDRIVE. Intelligent Constant Pressure. Water Supply Controller User Manual. idrive

ICON SERIES IDRIVE. Intelligent Constant Pressure. Water Supply Controller User Manual. idrive ICON SERIES IDRIVE Intelligent Constant Pressure Water Supply Controller User Manual idrive1150-240 CONTENTS PREFACE 3 1. PRODUCT DESCRIPTION 4 1.1 Functions Description 4 1.2 Model List 4 1.3 Nameplate

More information

Wise HP33 THREE PHASE HIGH PRECISION AVR SURVO-MOTOR AUTOMATIC VOLTAGE STABILIZER

Wise HP33 THREE PHASE HIGH PRECISION AVR SURVO-MOTOR AUTOMATIC VOLTAGE STABILIZER Wise HP33 THREE PHASE HIGH PRECISION AVR SURVO-MOTOR AUTOMATIC VOLTAGE STABILIZER LEN.MAN.STA.111 Rev.4.00/2010 CONTENTS 1. SAFETY INSTRUCTIONS 1 2. INTRODUCTION 2 3. FRONT PANEL AND CONNECTION BOARD 3

More information

ICON SERIES ipool. Swimming Pool Pump Controller. User Manual

ICON SERIES ipool. Swimming Pool Pump Controller. User Manual ICON SERIES ipool Swimming Pool Pump Controller User Manual PREFACE Thanks for choosing our ipool swimming pool pump controller. ipool is an intelligent controller which is specifically designed for swimming

More information

User Manual. Solar Inverter for Water Pump

User Manual. Solar Inverter for Water Pump User Manual Solar Inverter for Water Pump SP Revival Series Version: 1.2 Table Of Contents ABOUT THIS MANUAL... 1 Purpose... 1 Scope... 1 SAFETY INSTRUCTIONS... 1 Inspection... 1 Installation... 1 Operation...

More information

Sidewinder Pumps Inc. AC Timer/Controller

Sidewinder Pumps Inc. AC Timer/Controller Sidewinder Pumps Inc. AC Timer/Controller Page 1 of 12 Rev 032417 Table of Contents 1. Warnings-------------------------------------------------------------------------------------------------- 3 1.1.

More information

INSTRUCTION MANUAL STATION CONTROLLER SC1000 MOTOR PROTECTION ELECTRONICS, INC.

INSTRUCTION MANUAL STATION CONTROLLER SC1000 MOTOR PROTECTION ELECTRONICS, INC. INSTRUCTION MANUAL STATION CONTROLLER SC1000 MOTOR PROTECTION ELECTRONICS, INC. 2464 Vulcan Road, Apopka, Florida 32703 Phone: (407) 299-3825 Fax: (407) 294-9435 Revision Date: 9-11-08 Applications: Simplex,

More information

User Manual. 2.2KW/7.5KW/11KW Solar Inverter for Water Pump. Version: 1.8

User Manual. 2.2KW/7.5KW/11KW Solar Inverter for Water Pump. Version: 1.8 User Manual 2.2KW/7.5KW/11KW Solar Inverter for Water Pump Version: 1.8 Table Of Contents ABOUT THIS MANUAL... 1 Purpose... 1 Scope... 1 SAFETY INSTRUCTIONS... 1 Inspection... 1 Installation... 1 Operation...

More information

TPE, TPED Series 2000

TPE, TPED Series 2000 GRUNDFOS INSTRUCTIONS TPE, TPED Series 2000 Installation and operating instructions English (GB) English (GB) Installation and operating instructions Original installation and operating instructions. CONTENTS

More information

Chore-Tronics IDM Board Instruction

Chore-Tronics IDM Board Instruction Chore-Tronics IDM Board Instruction Caution, Warning and Danger Decals have been placed on the equipment to warn of potentially dangerous situations. Care should be taken to keep this information intact

More information

Pump control box without probe

Pump control box without probe Pump control box without probe Type GUARDIAN User s manual This symbol indicates a potential risk of electrical nature This symbol indicates a subject of particular importance 1.0 OVERVIEW This booklet

More information

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0 BS 287 DUAL CHANNEL POWER SUPPLY User Manual January 2017 V1.0 Table of contents 1.0 SAFETY INSTRUCTIONS... 3 2.0 GENERAL DESCRIPTION PS 289... 4 3.0 MECHANICAL INSTALLATION... 5 4.0 MAINS POWER & SAFETY

More information

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center.

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center. Liebert PSA iton User Manual Version: V2.8 Revision date: November 14, 2005 Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or

More information

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation: DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER The DKM-409 is a precision instrument designed for displaying various AC parameters in 3-phase distribution panels. Thanks to its isolated

More information

P216. Condenser fan speed controller. Product bulletin. Features

P216. Condenser fan speed controller. Product bulletin. Features P216 Condenser fan speed controller Product bulletin These controllers are designed for speed variation of single phase motors, especially for fan speed control on air cooled condensers. Head pressure

More information

User Manual. 2.2KW LS (Low PV Input Range) Solar Inverter for Water Pump. Version: 1.1

User Manual. 2.2KW LS (Low PV Input Range) Solar Inverter for Water Pump. Version: 1.1 User Manual 2.2KW LS (Low PV Input Range) Solar Inverter for Water Pump Version: 1.1 Table Of Contents ABOUT THIS MANUAL... 1 Purpose... 1 Scope... 1 SAFETY INSTRUCTIONS... 1 Inspection... 1 Installation...

More information

Supplementary operating instructions for your air curtain system Controller TMC 500

Supplementary operating instructions for your air curtain system Controller TMC 500 Supplementary operating instructions for your air curtain system Controller TMC 500 (Translation of the original) Serial number: Year: Please quote this number when contacting customer service! Date 08.04.2016

More information

WSK INTELLIGENT TEMPERATURE AND HUMIDITY CONTROLLER USER MANUAL

WSK INTELLIGENT TEMPERATURE AND HUMIDITY CONTROLLER USER MANUAL WSK INTELLIGENT TEMPERATURE AND HUMIDITY CONTROLLER USER MANUAL WSK INTELLIGENT TEMPERATURE AND HUMIDITY CONTROLLER USER MANUAL v 1.0 Thanks for choosing the Intelligent temperature and humidity controller

More information

Model HM-535 Power Supply Installation and Service Instructions

Model HM-535 Power Supply Installation and Service Instructions Model HM-535 Power Supply Installation and Service Instructions 430-535 0104 2004 Heritage MedCall, Inc SENTRY INSTALLATION & SERVICE INSTRUCTIONS POWER SUPPLY UNIT Model HM-535 IMPORTANT SAFETY INSTRUCTIONS

More information

99 Washington Street Melrose, MA Phone Toll Free Visit us at

99 Washington Street Melrose, MA Phone Toll Free Visit us at 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Table of Contents 1. General Safety Requirements... 1 2. Safety Terms and Symbols...

More information

MOBILE CONNECTOR - GEN 2 OWNER'S MANUAL

MOBILE CONNECTOR - GEN 2 OWNER'S MANUAL MOBILE CONNECTOR - GEN 2 OWNER'S MANUAL UNITED STATES Contents Safety Information... 2 Save These Important Safety Instructions... 2 Warnings...2 Cautions...3 General Information... 4 Mobile Connector

More information

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Raritan DANGER!

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Raritan DANGER! QUICK SETUP GUIDE BCM2 Series Branch Circuit Monitors Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable

More information

Valid for item nos.: (1-zone) (2-zone) (4-zone) (6-zone) HPS-C-Slot Hotrunner controllers Operating manual

Valid for item nos.: (1-zone) (2-zone) (4-zone) (6-zone) HPS-C-Slot Hotrunner controllers Operating manual Valid for item nos.: 68030.001 (1-zone) 68030.002 (2-zone) 68030.004 (4-zone) 68030.006 (6-zone) HPS-C-Slot Hotrunner controllers Operating manual 2 Content Safety instructions...3 Introduction...4 Operating

More information

2 Table of Contents 1. TABLE OF CONTENTS. 1. Table of Contents Introduction Wiring Diagram Terminals Review...

2 Table of Contents 1. TABLE OF CONTENTS. 1. Table of Contents Introduction Wiring Diagram Terminals Review... TPR-6 Temperature Protection Relay Instruction Manual Ver. June 1 st 2010 2 Table of Contents 1. TABLE OF CONTENTS 1. Table of Contents... 2 2. Introduction... 3 3. Wiring Diagram... 5 4. Terminals Review...

More information

R-LB R-LX Series Installation, Operation & Maintenance Manual

R-LB R-LX Series Installation, Operation & Maintenance Manual Installation, Operation & Maintenance Manual WARNINGS Safety First Hazardous Voltage & Shock Hazard Only qualified licensed electricians should install or service SPDs Hazardous voltages exist within SPDs

More information

APPLICATION CONTROL GUIDELINES. IntelliROL Power Supply PN Revision Date: March 15, 2017

APPLICATION CONTROL GUIDELINES. IntelliROL Power Supply PN Revision Date: March 15, 2017 APPLICATION CONTROL GUIDELINES IntelliROL Power Supply PN 1176718 Revision Date: March 15, 2017 Table of Contents List of Tables...3 TGW Safety Recommendation...4 Warnings and Safety Instructions...5 Introduction...6

More information

SC2000 MOTOR PROTECTION ELECTRONICS, INC. INSTRUCTION MANUAL. (407) Phone: Website:

SC2000 MOTOR PROTECTION ELECTRONICS, INC. INSTRUCTION MANUAL. (407) Phone: Website: SC2000 INSTRUCTION MANUAL MOTOR PROTECTION ELECTRONICS, INC. 2464 Vulcan Road Apopka, Florida 32703 Phone: Website: (407) 299-3825 www.mpelectronics.com Operating Program Revision: 12 Revision Date: 8-27-14

More information

INTRINSICALLY SAFE DUPLEXER PROTECTION. ELECTRONICS, INC Vulcan Road Apopka, Florida MOTOR INSTRUCTION MANUAL

INTRINSICALLY SAFE DUPLEXER PROTECTION. ELECTRONICS, INC Vulcan Road Apopka, Florida MOTOR INSTRUCTION MANUAL INTRINSICALLY SAFE DUPLEXER INSTRUCTION MANUAL MOTOR PROTECTION ELECTRONICS, INC. 2464 Vulcan Road Apopka, Florida 32703 Phone: Website: (407) 299-3825 www.mpelectronics.com Operating Program Revision:

More information

LCD LCDS LCDRI CONTROLLER OPERATING MANUAL

LCD LCDS LCDRI CONTROLLER OPERATING MANUAL This manual contains important safety information about installation and use of this equipment. Ignoring this information could result in injuries or damages. It is strictly forbidden to use this equipment

More information

SOLARIMMERSION IV Advanced Installation Manual v1.9

SOLARIMMERSION IV Advanced Installation Manual v1.9 SOLARIMMERSION IV Advanced Installation Manual v1.9 1 Contents 1. Overview 2. Technical Specifications 3. Installation Mounting Electrical Installation Clamp Installation Wiring Diagrams 4. Installation

More information

BCM2 Series Branch Circuit Monitors Quick Setup Guide

BCM2 Series Branch Circuit Monitors Quick Setup Guide BCM2 Series Branch Circuit Monitors Quick Setup Guide Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable

More information

EX-RC1 Remote I/O Adapter

EX-RC1 Remote I/O Adapter EX-RC1 Remote I/O Adapter The EX-RC1 interfaces between Unitronics Vision OPLCs and remote I/O Expansion Modules distributed throughout your system. The adapter is connected to a PLC via CANbus. Each adapter

More information

USER MANUAL INSTALLATION MANUAL. Isolation transformers. ITR Isolation Transformer 7000 W 230V/32A

USER MANUAL INSTALLATION MANUAL. Isolation transformers. ITR Isolation Transformer 7000 W 230V/32A USER MANUAL INSTALLATION MANUAL Isolation transformers ITR000702000 Isolation Transformer 7000 W 230V/32A Victron Energy B.V. The Netherlands General phone: +31 (0)36 535 97 00 Customer support desk: +31

More information

Sidewinder Pumps Inc. AC C1D2 Timer/Controller

Sidewinder Pumps Inc. AC C1D2 Timer/Controller Sidewinder Pumps Inc. AC C1D2 Timer/Controller Page 1 of 14 Rev 4/26/17 Table of Contents 1. Warnings --------------------------------------------------------------------------------------------------

More information

ATS CONTROLLER [ ACD-III ], [ ACD-III-C ] User s Manual. O-Sung Electric Machinery Co., Ltd.

ATS CONTROLLER [ ACD-III ], [ ACD-III-C ] User s Manual. O-Sung Electric Machinery Co., Ltd. ATS CONTROLLER [ ACD-III ], [ ACD-III-C ] User s Manual O-Sung Electric Machinery Co., Ltd. 136, Hataemal-gil, Wollong-Myeon Paju-si, Gyeonggi-do, Korea Tel : (031) 944-3521 / Fax : (031) 944-3525 http://www.osemco.com

More information

EX-RC1 Remote I/O Adapter

EX-RC1 Remote I/O Adapter EX-RC1 Remote I/O Adapter The EX-RC1 interfaces between Unitronics Vision OPLCs and remote I/O Expansion Modules distributed throughout your system. The adapter is connected to a PLC via CANbus. Each adapter

More information

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016 Operating instructions AS-i SmartLine module AC3200 AC3201 80237876/00 06/2016 Contents 1 Preliminary note...3 1.1 Symbols used...3 1.2 Warnings used...3 2 Safety instructions...3 2.1 General...3 2.2 Target

More information

H704-42(H)(E), H704-42/1(H)(E)

H704-42(H)(E), H704-42/1(H)(E) POWER MONITORING INSTALLATION GUIDE H704-42(H)(E), H704-42/1(H)(E) Branch Current Monitor DANGER NOTICE Installer's Specifications General: Operating Temp. Range 0 to 60 C (32 to 140 F) (

More information

MAKING MODERN LIVING POSSIBLE. Installation Guide. Twin Kit 086L

MAKING MODERN LIVING POSSIBLE. Installation Guide. Twin Kit 086L MAKING MODERN LIVING POSSIBLE Installation Guide 086L70 www.heating.danfoss.com Danfoss A/S is not liable or bound by warranty if these instructions are not adhered to during installation or service. The

More information

TVAC25100 TVAC25110 User manual

TVAC25100 TVAC25110 User manual TVAC25100 TVAC25110 User manual Version 11/2010 Original user manual. Keep for future use. 12 Introduction Dear Customer, Thank you for purchasing this product. This product meets the requirements of the

More information

User manual. TRIOU(Temperature Remote I/O Unit) Before using the product, be sure to read Safety Cautions, and use exactly as described.

User manual. TRIOU(Temperature Remote I/O Unit) Before using the product, be sure to read Safety Cautions, and use exactly as described. User manual TRIOU(Temperature Remote I/O Unit) Before using the product, be sure to read Safety Cautions, and use exactly as described. After reading the user manual, keep it in a place where users of

More information

Carbon Monoxide Sensor - ModBus

Carbon Monoxide Sensor - ModBus Introduction The CO Sensor uses an electrochemical sensor to monitor CO level in a range of 0 to 500 ppm and communicates via an RS-485 network configured for ModBus protocol. Before Installation Read

More information

Instructions for use:

Instructions for use: JN MPPT-A 10~40A Solar Controller User Manual Product features: Advanced MPPT maximum power point tracking technology, and tracing efficiency not less than 99.5%. Compared to common PWM algorithm, it achieves

More information

Quick Start Installation and User Manual

Quick Start Installation and User Manual 1 Quick Start Installation and User Manual Contents 1. Overview 2. Technical Specifications 3. Installation Mounting Electrical Installation Clamp Installation Wiring Diagrams 4. Installation Settings

More information

TO AVOID FIRE, SHOCK, OR DEATH; SHUT OFF POWER SUPPLY AT THE CIRCUIT BREAKER OR FUSE AND TEST THAT THE POWER IS OFF BEFORE WIRING.

TO AVOID FIRE, SHOCK, OR DEATH; SHUT OFF POWER SUPPLY AT THE CIRCUIT BREAKER OR FUSE AND TEST THAT THE POWER IS OFF BEFORE WIRING. OWNER S MANUAL Congratulations on your purchase of a UPM timer. Please take the time to read and understand this manual so you can begin to enjoy the security and energy saving benefits this product has

More information

I/O module (Expansion module)

I/O module (Expansion module) I/O module (Expansion module) Variomat Variomat Giga Reflexomat Servitec V2.00 02.02.2015 GB Operating manual Original operating manual English I/O module (Expansion module) Contents 02.02.2015 Contents

More information

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual Document 481200 VGD-100 Vari-Green Drive Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install,

More information

PRODUCT MANUAL SMOKE-1500 ENGLISH. Version: 1.0

PRODUCT MANUAL SMOKE-1500 ENGLISH. Version: 1.0 PRODUCT MANUAL SMOKE-1500 ENGLISH Version: 1.0 CONTENTS Warning 1 Caution 3 Please note: 3 Important 3 Description 4 Figure 1 SMOKE-1500 Functions 5 Getting ready 6 Set Up 6 DMX Connector Pin Assignment

More information

Operation Manual. Concorde 600 Power Supply. *This instrument is intended for laboratory use only.

Operation Manual. Concorde 600 Power Supply. *This instrument is intended for laboratory use only. Concorde 600 Power Supply Operation Manual Cat.no. R10-1001011 *This instrument is intended for laboratory use only http://www.recenttec.com E-mail : support@recenttec.com Version 1.1 Packing List x 1

More information

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service.

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service. PM Series Power Meter QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB-1960 Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA

More information

Three-Phase Solar Pump Controller 1.5 kw 380V User Manual

Three-Phase Solar Pump Controller 1.5 kw 380V User Manual Three-Phase Solar Pump Controller 1.5 kw 380V User Manual Manual Version: SPC3P1.5-380- 2016-1-N Table of Contents 1. IMPORTANT INFORMATION AND SAFETY INSTRUCTIONS... 1 2. INTRODUCTION... 2 2.1 General

More information

RTD-W Installation Instructions

RTD-W Installation Instructions RTD-W Installation Instructions 0V +V POWER 15-24VDC 0V S1 S2 S3 0V S4 S5 S6 English RTD-W Installation Instructions 100.00 RTD-W Control Interface realtime Control Systems 24VAC/30VDC, 1A REMC P1 P2 RS485

More information

Instructions for use:

Instructions for use: JN MPPT-C 50~100A Solar Controller User Manual Product features: Advanced MPPT maximum power point tracking technology, and tracing efficiency not less than 99.5%. Compared to common PWM algorithm, it

More information

AUDIO AND VIDEO DOOR ENTRY SYSTEM WITH NEXA CODED PANEL

AUDIO AND VIDEO DOOR ENTRY SYSTEM WITH NEXA CODED PANEL AUDIO AND VIDEO DOOR ENTRY SYSTEM WITH NEXA CODED PANEL 2 INTRODUCTION First and foremost we would like to thank you for purchasing this product. Our commitment to satisfying our customers can be seen

More information

SC2000 MOTOR PROTECTION ELECTRONICS, INC. INSTRUCTION MANUAL. Phone: (407) Fax: (407) Vulcan Road Apopka, Florida 32703

SC2000 MOTOR PROTECTION ELECTRONICS, INC. INSTRUCTION MANUAL. Phone: (407) Fax: (407) Vulcan Road Apopka, Florida 32703 SC2000 INSTRUCTION MANUAL MOTOR PROTECTION ELECTRONICS, INC. 2464 Vulcan Road Apopka, Florida 32703 Phone: (407) 299-3825 Fax: (407) 294-9435 Operating Program Revision: 10 Revision Date: 1-9-12 STATION

More information

EATON 5S 850/1200/1600

EATON 5S 850/1200/1600 www.eaton.com EATON 5S 850/1200/1600 Installation and user manual Packaging EATON 5S 1 2 3 5 Caution! l Before installing the Eaton 5S, read the booklet 3 containing the safety instructions to be respected.

More information

GRUNDFOS INSTRUCTIONS. Control MPC. Installation and operating instructions

GRUNDFOS INSTRUCTIONS. Control MPC. Installation and operating instructions GRUNDFOS INSTRUCTIONS Control MPC Installation and operating instructions English (GB) English (GB) Installation and operating instructions Original installation and operating instructions CONTENTS Page

More information

HPS-M -2 DIFFERENTIAL PRESSURE TRANSMITTER. Mounting and operating instructions

HPS-M -2 DIFFERENTIAL PRESSURE TRANSMITTER. Mounting and operating instructions DIFFERENTIAL PRESSURE Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 5 OPERATIONAL

More information

Operating Manual LF1-LF4 i

Operating Manual LF1-LF4 i Operating Manual Oct. 2005 Fillerkampsweg 1 5 31832 Springe OT Eldagsen Tel.: 05044/887-0 (Fax: -99) E-Mail: info@iotronic.de Internet: http://www.iotronic.de Page 3 Contents 1.0 General Guidelines for

More information

Table of Contents. 3.1 Front/Rear Panel and User Interface Front Panel Rear Panel User Interface...

Table of Contents. 3.1 Front/Rear Panel and User Interface Front Panel Rear Panel User Interface... General Warranty OWON warrants that the product will be free from defects in materials and workmanship for a period of 2 years (1 year for accessories) from the date of purchase of the product by the original

More information

[ ACD-NA ] User s Manual. O-Sung Electric Machinery Co., Ltd. 136, Hataemal-gil, Wollong-Myeon Paju-si, Gyeonggi-do, Korea

[ ACD-NA ] User s Manual. O-Sung Electric Machinery Co., Ltd. 136, Hataemal-gil, Wollong-Myeon Paju-si, Gyeonggi-do, Korea [ ACD-NA ] User s Manual O-Sung Electric Machinery Co., Ltd. 136, Hataemal-gil, Wollong-Myeon Paju-si, Gyeonggi-do, Korea Tel : (031) 944-3521 / Fax : (031) 944-3525 http://www.osemco.com / ousung@chol.com

More information

Installation Manual. 1.Included Accessories. System Controller SC-201-6M INT. Requests to Installers *SHA8754 C*

Installation Manual. 1.Included Accessories. System Controller SC-201-6M INT. Requests to Installers *SHA8754 C* System Controller SC-201-6M INT Installation Manual Potential dangers from accidents during installation and use are divided into the following two categories. Closely observe these warnings, they are

More information

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS MAINTENANCE MANUAL EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS SPECIFICATIONS*... 2 INTRODUCTION... 3 DESCRIPTION...

More information

EX-RC1 Remote I/O Adapter

EX-RC1 Remote I/O Adapter EX-RC1 Remote I/O Adapter The EX-RC1 interfaces between Unitronics Vision OPLCs and remote I/O Expansion Modules distributed throughout your system. The adapter is connected to a PLC via CANbus. Each adapter

More information

Operating instructions. Switching amplifier DN0210 DN / / 2015

Operating instructions. Switching amplifier DN0210 DN / / 2015 Operating instructions Switching amplifier DN0210 DN0220 UK 80011079 / 00 01 / 2015 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5

More information

INSPECTION CAMERA MODEL NO: CIC2410 OPERATION & SAFETY INSTRUCTIONS PART NO: GC0116

INSPECTION CAMERA MODEL NO: CIC2410 OPERATION & SAFETY INSTRUCTIONS PART NO: GC0116 INSPECTION CAMERA MODEL NO: CIC2410 PART NO: 6470385 OPERATION & SAFETY INSTRUCTIONS GC0116 INTRODUCTION Thank you for purchasing this CLARKE Inspection Camera. Before attempting to use this product, please

More information

General Warranty. For more details, please refer to the user manual on the supplied CD, it can also be downloaded at

General Warranty. For more details, please refer to the user manual on the supplied CD, it can also be downloaded at General Warranty Lilliput warrants that the product will be free from defects in materials and workmanship for a period of 3 years (1 year for accessories) from the date of purchase of the product by the

More information

INSTALLATION INSTRUCTIONS MBPEFY Series Mixing Box for Mitsubishi PEFY Series Units. Before Starting Installation Warning. Installation Instructions

INSTALLATION INSTRUCTIONS MBPEFY Series Mixing Box for Mitsubishi PEFY Series Units. Before Starting Installation Warning. Installation Instructions Before Starting Installation Warning Shut power to unit prior to any work being done. Personal injury or death could result. Only qualified HVAC service personnel should install, troubleshoot, repair or

More information

ATS22D17Q soft starter-ats22-control 220V-power 230V (4kW)/ V(7.5kW)

ATS22D17Q soft starter-ats22-control 220V-power 230V (4kW)/ V(7.5kW) Product datasheet Characteristics ATS22D17Q soft starter-ats22-control 220V-power 230V (4kW)/400...440V(7.5kW) Complementary Assembly style Function available Supply voltage limits Main Range of product

More information

User Manual. Item no.: Otto Graf GmbH Carl-Zeiss-Str. 2-6 Tel.: +49(0) Kunststofferzeugnisse D Teningen Fax: +49(0)

User Manual. Item no.: Otto Graf GmbH Carl-Zeiss-Str. 2-6 Tel.: +49(0) Kunststofferzeugnisse D Teningen Fax: +49(0) User Manual AquaControl + Rainwater System Controller Item no.: 351027 Otto Graf GmbH Carl-Zeiss-Str. 2-6 Tel.: +49(0)7641-5890 Kunststofferzeugnisse D-79 331 Teningen Fax: +49(0)7641-58950 Page 1 Figure

More information

MicroTech III Applied Terminal Systems BACnet MS/TP Communication Module

MicroTech III Applied Terminal Systems BACnet MS/TP Communication Module Installation and Maintenance Manual IM 928-2 Group: Controls Part Number: 669207702 Date: March 2011 Supersedes: IM 928-1 MicroTech III Applied Terminal Systems BACnet MS/TP Communication Module NOTICE

More information

Operating instructions. Speed monitor D / / 2014

Operating instructions. Speed monitor D / / 2014 Operating instructions Speed monitor D200 80005257 / 00 05 / 2014 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5 2.2 Target group...5

More information

ATS22D47S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

ATS22D47S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection Product datasheet Characteristics ATS22D47S6U Complementary Assembly style Function available Supply voltage limits Main Range of product Altistart 22 Product or component type Product destination Product

More information

Autoranging True RMS Multimeter User Manual

Autoranging True RMS Multimeter User Manual Autoranging True RMS Multimeter User Manual Please read this manual before switching the unit on. Important safety information inside. Contents Page 1. Safety Information... 4 2. Safety Symbols... 5 3.

More information

HCS-3600 / 3602 / 3604 Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control

HCS-3600 / 3602 / 3604 Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control HCS-3600 / 3602 / 3604 Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control 1. INTRODUCTION User Manual This family of efficient, upgraded SMPS with small form factor,

More information

Installation and Operation Back-UPS BR1000G-IN / BR1500G-IN

Installation and Operation Back-UPS BR1000G-IN / BR1500G-IN Installation and Operation Back-UPS BR1000G-IN / BR1500G-IN Important Safety Information Read the instructions carefully to become familiar with the equipment before trying to install, operate, service

More information

ATS22D75S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

ATS22D75S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection Product datasheet Characteristics ATS22D75S6U Complementary Assembly style Function available Supply voltage limits Main Range of product Altistart 22 Product or component type Product destination Product

More information

w w w. p r o l i g h t. c o. u k STAGE PAR 64

w w w. p r o l i g h t. c o. u k STAGE PAR 64 w w w. p r o l i g h t. c o. u k STAGE PAR 64 Order code: LEDJ40 (Black) Order code: LEDJ41 (Polished) Order code: LEDJ42 (Black) Order code: LEDJ43 (Polished) Order code: LEDJ44 (Black) Order code: LEDJ45

More information

KOBOLD PDA Series Digital Pressure Transmitter

KOBOLD PDA Series Digital Pressure Transmitter KOBOLD PDA Series Digital Pressure Transmitter PDA-153 Series User Instructions KOBOLD Instruments Inc. 1801 Parkway View Drive Pittsburgh, PA 15205 Phone (412) 788-2830 Fax (412)-788-4890 www.koboldusa.com

More information

CoolPlug CooLinkHub HVAC Bridge. Quick Installation Guide

CoolPlug CooLinkHub HVAC Bridge. Quick Installation Guide CoolPlug CooLinkHub HVAC Bridge Quick Installation Guide Warning Read and understand the following Safety Guidelines and Warnings to ensure a safe installation Failure to follow WARNING may result in

More information

Quick Start Guide TS A

Quick Start Guide TS A Quick Start Guide TS 930 125-630A DANGER HAZARD OF ELECTRICAL SHOCK, EXPLOSION, OR ARC FLASH Read and understand this quick start guide before installing and operating the transfer switch The installer

More information

Procon A1M. INSTALLATION MANUAL Version MITSUBISHI ELECTRIC FOR INSTALLERS

Procon A1M. INSTALLATION MANUAL Version MITSUBISHI ELECTRIC FOR INSTALLERS Procon A1M FOR INSTALLERS INSTALLATION MANUAL Version 1.1.1 For safe and correct use, please read this installation manual thoroughly before installing the PROCON A1M. MITSUBISHI ELECTRIC Preface Safety

More information

ALPHA Automated Transfer Switch Operating Manual. Rev 1.21 The original of this document is drawn up in English language

ALPHA Automated Transfer Switch Operating Manual. Rev 1.21 The original of this document is drawn up in English language ALPHA Automated Transfer Switch Operating Manual Rev 1.21 The original of this document is drawn up in English language ATS Manual Rev 1.21 Alpha Technologies GmbH 2013 Table of Contents 1. Safety Instructions...

More information

PS 289 DUAL CHANNEL POWER SUPPLY USER MANUAL

PS 289 DUAL CHANNEL POWER SUPPLY USER MANUAL PS 289 DUAL CHANNEL POWER SUPPLY USER MANUAL August 2016 This product is designed and manufactured by: ASL Intercom B.V. Zonnebaan 42 3542 EG Utrecht The Netherlands Phone: +31 (0)30 2411901 Fax: + 31

More information

DPC Warning. ! Do not pull the cable. Water Pump Digital Pressure Controller Installation and Operation Manual.

DPC Warning. ! Do not pull the cable. Water Pump Digital Pressure Controller Installation and Operation Manual. 11.Warning www.evak-pumps.com Assemble tool! Do not pull the cable! Do not poke the port! WARNING Wire conductors must not be exposed to avoid any shortage from the conductor end. DPC-10 Water Pump Digital

More information

Industrial motor controller for brushed DC motors 24 VDC

Industrial motor controller for brushed DC motors 24 VDC Industrial motor controller for brushed DC motors 24 VDC Design for output currents up to 6 A Control with the following functions: - reversal of direction of rotation - overcurrent shutdown depends on

More information

EPS Power Supply

EPS Power Supply EPS - 600 Power Supply Installation and Operation Manual Version 1.0 *This instrument is intended for laboratory use only Index A. Important Notice ----------------------------------------------------------------

More information

Installation and Operation Manual. ETV Platinum Plus. Electronic Tempering Valve with Safeguard WARNING

Installation and Operation Manual. ETV Platinum Plus. Electronic Tempering Valve with Safeguard WARNING Installation and Operation Manual ETV Platinum Plus Electronic Tempering Valve with Safeguard WARNING This Heat-Timer control is strictly an operating control; it should never be used as a primary limit

More information

MU110-6U. Analog output module 6 channel. User guide

MU110-6U. Analog output module 6 channel. User guide MU110-6U Analog output module 6 channel User guide MU110-6U_2016.12_0221_EN All rights reserved Subject to technical changes and misprints akytec GmbH Vahrenwalder Str. 269 A 30179 Hannover Тел.: +49 (0)

More information

Installation Instructions

Installation Instructions Please read all instructions before installing SPECIFICATIONS RT-100 Time Switch Programmable Countdown Voltage...120VAC, 60HZ Load (Single Pole Circuit) Incandescent or fluorescent lamp... 0 600 Watt

More information

SMPT Solar Pump Controller. User Manual

SMPT Solar Pump Controller. User Manual SMPT Solar Pump Controller User Manual Preface Thank you for using SMPT series products, this manual provides you with relevant operation instructions and detailed description of parameters. Please read

More information

Table of Contents. Automatic Transfer Switch. User Manual ATS-16A/20A/30A/32A

Table of Contents. Automatic Transfer Switch. User Manual ATS-16A/20A/30A/32A Table of Contents 1. Important Safety Instructions... 2 2. Overview... 3 3. Product Functional Description... 4 3.1. Front Panel... 4 3.2. LCD Display Description... 5 3.3. Rear Panel... 6 3.4. Communication

More information

UC102 basic version with display and knob UC102BL version with display, knob and backlight UC102DK version without knob and display

UC102 basic version with display and knob UC102BL version with display, knob and backlight UC102DK version without knob and display UC102 Communicative heating controller Summary UC102 is a communicative room heating controller with two inputs and one PWM output for control of a radiator or electrical heater. It can work autonomously,

More information

Blitzer Strobe. User Manual. Order code: EQLED366

Blitzer Strobe. User Manual. Order code: EQLED366 Blitzer Strobe User Manual Order code: EQLED366 Safety advice WARNING FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START-UP! Before your initial start-up, please make

More information

AP Series Variable Frequency Drives Operation & Installation Manual

AP Series Variable Frequency Drives Operation & Installation Manual AP Series Variable Frequency Drives Operation & Installation Manual i SAFETY MESSAGES AND WARNINGS To ensure safe and reliable operation of the AquaPhase AP Series pump converter, it is important to carefully

More information

w w w. p r o l i g h t. c o. u k Quad Par 64 (Order code: LEDJ46 - Black) (Order code: LEDJ47 - Polished) USER MANUAL

w w w. p r o l i g h t. c o. u k Quad Par 64 (Order code: LEDJ46 - Black) (Order code: LEDJ47 - Polished) USER MANUAL w w w. p r o l i g h t. c o. u k Quad Par 64 (Order code: LEDJ46 - Black) (Order code: LEDJ47 - Polished) USER MANUAL Safety WARNING FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR

More information

Output Signal Active Note DC V. Electrical Data Power Supply DC V, ±10%, 1.4 W

Output Signal Active Note DC V. Electrical Data Power Supply DC V, ±10%, 1.4 W Differential Pressure Sensor (Air) Differential pressure transmitter with 8 selectable ranges 0 to 5/10 V, 4 to 20 ma outputs and Modbus functionality. NEMA 4X / IP65 rated enclosure. For monitoring the

More information

UNIT CONTROLLER 7 (UC7) Operation & Installation. Hydronic Units

UNIT CONTROLLER 7 (UC7) Operation & Installation. Hydronic Units UNIT CONTROLLER 7 (UC7) Operation & Installation Hydronic Units Date: 1 November 2012 Issue: 5 Page 1 of 17 Contents 1. Connections, hydronic unit... 3 2. Functions assigned to SSR1, SSR2 and AUX... 3

More information

Transient Fault Location for Energized Dedicated Circuit Breakers. TFT100 User Manual. Toll Free:

Transient Fault Location for Energized Dedicated Circuit Breakers. TFT100 User Manual. Toll Free: Transient Fault Location for Energized Dedicated Circuit Breakers TFT100 User Manual Toll Free: 800-749-5783 Introduction This product should only be used by and connected/ disconnected from a circuit

More information