1 DeltaV SIS Process Safety System Product Data Sheet November 2017 CTO CSLS CHARM Cabinets Rear View CTO CSLS CHARM Cabinet. Delivers Electronic Marshalling enabled by CHARMs technology Reduce system footprint Eliminate I/O home run cables Significantly reduce cabinet design engineering Fully documented package Introduction The DeltaV SIS Configure-To-Order (CTO) CHARMs Smart Logic Solver (CSLS) Cabinets provide an off-the-shelf solution for faster project execution and reduced installation costs. CTO CSLS Cabinets are factory tested and ready for installation in technical rooms. Electronic Marshalling eliminates traditional I/O design tasks and allows field wiring to start long before safety strategies are finalized.
2 Benefits Delivers Electronic Marshalling enabled by CHARMs technology: The CTO CSLS Cabinets offer the full benefits of Electronic Marshalling. The individual channels can be defined for any combination of field signal type, as required by the safety equipment. This allows for 100 % utilization of channels, regardless of the I/O signal mix. Late changes are easily accommodated with minimal re-engineering and no rewiring. Reduced system footprint: Equipment room footprint is reduced by eliminating the traditional marshalling cabinets with cross wiring to traditional I/O cards. Significantly reduce cabinet design engineering: The CTO CSLS cabinets are pre-engineered and factory tested. The I/O flexibility allows the same design to serve a wide variety of I/O signals, conditioned individually by the CHARM. Field wiring design is complete at the terminal block. Fully documented package: Each cabinet is supplied with full documentation and engineering drawings showing internal layout, bill of materials and internal wiring. They are designed to meet local building code and industry best practices in order to deliver proven functionality with minimal costs. Product Description The CTO CSLS Cabinets offering comprises a range of preengineered solutions based on industry standard, preinstalled with CHARM I/O and related equipment, ready to be installed in an equipment room and connected to safety instrumentation or equipment. The cabinets are typical, free standing enclosures intended for floor mounting in equipment room areas, where temperature and humidity are controlled within the requirements for computer/electronic equipment. They come ready to receive incoming plant AC power. All internal wiring to power distribution components and grounding conductors has been tested at the factory. Before delivery, each cabinet undergoes a full in-house inspection, to assure that it is fully operational before shipping directly to site. Electronic Marshalling eliminates the need for any internal cross wiring and I/O rationalization there is typically no need for FAT at a staging facility. These cabinets can be ordered and delivered directly together with the DeltaV SIS electronic marshalling equipment and LS CHARM I/O to site to begin field wiring (FAT may be optional). The CTO CSLS Cabinets are configured by selecting a base enclosure model and required options to meet specific project needs. Base enclosure models are available: For different cabinet sizes / entry (Front Access or Front and Rear access). For different power distribution needs: DC powered or AC powered. For different world area design standards and regulations: EUR (Europe) and NA (US/Canada). Configurable options examples: the type of LS CHARMS (I.S. or non I.S.), side panels, cabinet light, nameplate engraving and injected power. All CTO CSLS cabinets come with following equipment installed. Primary and secondary 24VDC power distribution for LS CHARM I/O Cards and field instrumentation. Wire ducts or wire basket. Grounding bars. Wiring plan pocket. Emerson Name Plate Holder and blank name plate insert. DeltaV LS CHARM I/O equipment based on your configuration (and priced seperately): including CSLS carriers, CHARM base plates, standard terminal blocks, address plugs and terminals. The CSLS cards and LS CHARMs are not included and are to be ordered separately. The required number of (redundant) LS CHARM I/O cards and CSLS cards depends on the actual number and types of I/O that will be wired into the cabinet. The following sections provide a more detailed specification for the CTO CSLS Cabinets and available options. 2
3 Overview of CTO CSLS Cabinets Base Models Base Model number Description # LS CHARM IO Power Requirements (Pri and Sec) Permitted Location / World Area EU-CAB-800F-192-AC-CSLS AC Powered SIS Electronic Marshalling cabinet for 192 LS CHARM I/O; 800mm W x 600mm D; Front Access Safe Area Locations VAC Safe Area EUR EU-CAB-800FR-480-AC-CSLS AC Powered SIS Electronic Marshalling cabinet for 480 LS CHARM I/O; 800mm W x 800mm D; Front and Rear Access; Safe Area Locations VAC Safe Area EUR NA-CAB-800F-192-AC-CSLS AC Powered SIS Electronic Marshalling cabinet for 192 LS CHARM I/O; 800mm W x 600mm D; Front Access Safe Area Locations VAC Safe Area US/CANADA NA-CAB-800F-252-AC-CSLS AC Powered SIS Electronic Marshalling cabinet for 252 LS CHARM I/O; 800mm W x 600mm D; Front Access Safe Area Locations VAC Safe Area US/CANADA NA-CAB-800FR-480-AC-CSLS AC Powered SIS Electronic Marshalling cabinet for 480 LS CHARM I/O; 800mm W x 800mm D; Front and Rear Access; Safe Area Locations VAC Safe Area US/CANADA NA-CAB-800FR-504-AC-CSLS AC Powered SIS Electronic Marshalling cabinet for 504 LS CHARM I/O; 800mm W x 800mm D; Front and Rear Access; Safe Area Locations VAC Safe Area US/CANADA The CTO base model reference for cabinets uses the following naming convention: EUR or NA-CAB-XXXYY-ZZZIO-IP-DDDD, where EUR : Europe Design Standards and Regulations / NA : US/Canada Design Standards and Regulations. XXX = cabinet width (mm), e.g. 800, YY = F for Front only access (600 mm deep), FR for Front and Rear access (800 mm deep). ZZZ= maximum I/O s count in this CTO. IP= Incoming Power, DC=24V DC or AC=120/230V AC. DDDD= short description of content and purpose. 3
4 Overview of CTO CSLS Cabinets models and Options : Default option setting o : Configure To Order option setting, different from default blank : option setting not possible for the base enclosure : Intentionally left blank to fill in your configuration choices Nameplate Engraving G Enclosure Options Base Model NA-CAB-800F-252-AC-CSLS NA-CAB-800FR-504-AC-CSLS World Area US/CAN US/CAN US/CAN US/CAN EUR EUR Power Input (DC: 24VDC, AC:120/230VAC) AC AC AC AC AC AC Enclosure Access (F: Front, FR: Front-Rear) F F/R F F/R F F/R # CHARMI/O No 1 Yes NA-CAB-800F-192-AC-CSLS NA-CAB-800FR-480-AC-CSLS EU-CAB-800F-192-AC-CSLS EU-CAB-800FR-480-AC-CSLS Type of CHARMS (to be specified for each row of CHARMS) Cabinet Light Temperature Monitoring Door Fans Plinth Side Panels Door Hing Cable Routing Baying Kit Cable Clamps Rail Utility Socket Selection 24VDC for Injected Power Certification C L T F D S H B B R U V Z 1 Non I.S. 2 I.S. 1 No 2 LED light with motion sensor 0 No 1 Thermostat 1 Continuous Run 2 Thermostat Controlled 1 100mm N/A 2 200mm 0 No 1 Yes 1 Left Hinged N/A 2 Right Hinged 1 Cable Duct N/A 2 Wire Basket 0 No 1 Yes 0 No 1 Yes 0 No N/A 1 Yes 1 Front side No 2 Front side Yes 3 Rear side No N/A 4 Rear side Yes 0 No 1 CE N/A 2 CSA N/A N/A N/A Following more detailed options can be specified upon order (if applicable) : Disconnect switches for DC power feeds can be configured separately for CSLS power and for injected power inputs Type of utility socket : German-Russia / France-Poland / Switzerland / UK-Ireland / USA-Canada / Italy Power supply configuration : Power for CSLS and/or injected power (with diode), Front and Rear position in cabinet 24VDC for injected power : optionally prewired (according specification to be provided) Wiring color scheme different from default : US (L- Black, N- White) / EUR (L- Brown, N- Blue) Input Voltage different from default : US (120VAC) / EUR (230VAC) 4
5 Dimensions Access Protection Category IP54 NEMA 12 NA-CAB-800F-252-AC-CSLS 800mm (W) x 600mm (D) x 2000mm (H) + 100mm Plinth Front Access single door, right hand hinged, latch type lock and 2 sets of keys (key N 3524E) Approximate Weight Color Door Fans Temperature Monitoring Other Environmental Specifications Certifications Input Power ~ 200 kg Cabinet RAL7035, Plinth RAL7022 Configurable: Continuous run or with thermostat control Configurable: Thermostat Louvered doors with filter, mounting plate, grounding bars, wiring plan pocket, lifting eye bolts on top, bottom cable entry, removable gland plate Equipment/rack room installation (HVAC controlled), 30 C Max. Installation in Safe Area locations; Default Certification: CE (Europe); Optional: None Primary and Secondary 110 VAC Power Supply Rating Internal Power Distribution Local Safety Network Example Layout and Installed Equipment: Fixed 2 x 40A AC Distribution subassembly (mounted in left side) Fully redundant 24VDC distribution for CHARM I/O cards and bussed field power through switches and fused terminals (mounted in right side). Redundant 100BASE-FX, RJ45 connectors, to be connected to each CSLS carrier. Primary and Secondary Local Safety Network to 3 CSLS carriers is included. Example BOM: Power Supply subassembly. 3 LS CHARM IO rails, for total of 252 LS I/O, 3 x CSLS Carrier with redundant Copper Ethernet connectors 21 x CHARM Base Plate 21 x CHARM Address Plug 252 x CHARM terminal blocks - Screw type 3 x CHARM I/O bus termination Base Plate and Channel Identifier Labels No DeltaV equipment is included in the base model. All DeltaV equipment is to be configured separately through the Emerson quoting tools. Size of Wire Baskets: 150mm H x 54mm D 5
6 NA-CAB-800F-252-AC-CSLS External Layout Drawing for NA-CAB-800F-252-AC-CSLS: Front and. 6
7 Dimensions Access Protection Category IP54 NEMA 12 NA-CAB-800FR-504-AC-CSLS 800mm (W) x 800mm (D) x 2000mm (H) + 100mm Plinth Front Access single door, right hand hinged, latch type lock and 2 sets of keys (key N 3524E) Approximate Weight Color Door Fans Temperature Monitoring Other Environmental Specifications Certifications Input Power ~ 300 kg Cabinet RAL7035, Plinth RAL7022 Configurable: Continuous run or with thermostat control Configurable: Thermostat Louvered doors with filter, mounting plate, grounding bars, wiring plan pocket, lifting eye bolts on top, bottom cable entry, removable gland plate Equipment/rack room installation (HVAC controlled), 30 C Max. Installation in Safe Area locations; Default Certification: CE (Europe); Optional: None Primary and Secondary 110 VAC Power Supply Rating Internal Power Distribution Local Safety Network Example Layout and Installed Equipment: Fixed 2 x 40A AC Distribution subassembly (mounted in left side). Fully redundant 24VDC distribution for CHARM I/O cards and bussed field power through switches and fused terminals (mounted in right side). Redundant 100BASE-FX, RJ45 connectors, to be connected to each CSLS carrier. Primary and Secondary Local Safety Network to 3 CSLS carriers is included. Example BOM: Power Supply subassembly. 6 LS CHARM IO rails, for total of 504 LS I/O, 6 x CSLS Carrier with redundant Copper Ethernet connectors 42 x CHARM Base Plate 42 x CHARM Address Plug 504 x CHARM terminal blocks - Screw type 6 x CHARM I/O bus termination Base Plate and Channel Identifier Labels No DeltaV equipment is included in the base model. All DeltaV equipment is to be configured separately through the Emerson quoting tools. Rear View Size of Wire Baskets: 150mm H x 54mm D 7
8 NA-CAB-800FR-504-AC-CSLS Rear View External Layout Drawing for NA-CAB-800FR-504-AC-CSLS: Front/Rear and. 8
9 Dimensions Access Protection Category IP54 NEMA 12 NA-CAB-800F-192-AC-CSLS 800mm (W) x 600mm (D) x 2000mm (H) + 100mm Plinth Front Access single door, right hand hinged, latch type lock and 2 sets of keys (key N 3524E) Approximate Weight Color Door Fans Temperature Monitoring Other Environmental Specifications Certifications Input Power ~ 200 kg Cabinet RAL7035, Plinth RAL7022 Configurable: Continuous run or with thermostat control Configurable: Thermostat Louvered doors with filter, mounting plate, grounding bars, wiring plan pocket, lifting eye bolts on top, bottom cable entry, removable gland plate Equipment/rack room installation (HVAC controlled), 30 C Max. Installation in Safe Area locations; Default Certification: CE (Europe); Optional: None Primary and Secondary 110 VAC Power Supply Rating Internal Power Distribution Local Safety Network Example Layout and Installed Equipment: Fixed 2 x 40A AC Distribution subassembly (mounted in left side). Fully redundant 24VDC distribution for CHARM I/O cards and bussed field power through switches and fused terminals (mounted in right side). Redundant 100BASE-FX, RJ45 connectors, to be connected to each CSLS carrier. Primary and Secondary Local Safety Network to 2 CSLS carriers is included. Example BOM: Power Supply subassembly. 2 LS CHARM IO rails, for total of 192 LS I/O, 2 x CSLS Carrier with redundant Copper Ethernet connectors 16 x CHARM Base Plate 16 x CHARM Address Plug 192 x CHARM terminal blocks - Screw type 2 x CHARM I/O bus termination Base Plate and Channel Identifier Labels No DeltaV equipment is included in the base model. All DeltaV equipment is to be configured separately through the Emerson quoting tools. Size of Wire Baskets: 150mm H x 54mm D 9
10 NA-CAB-800F-192-AC-CSLS External Layout Drawing for NA-CAB-800F-192-AC-CSLS: Front and. 10
11 Dimensions Access Protection Category IP54 NEMA 12 NA-CAB-800FR-480-AC-CSLS 800mm (W) x 800mm (D) x 2000mm (H) + 100mm Plinth Front Access single door, right hand hinged, latch type lock and 2 sets of keys (key N 3524E) Approximate Weight Color Door Fans Temperature Monitoring Other Environmental Specifications Certifications Input Power ~ 300 kg Cabinet RAL7035, Plinth RAL7022 Configurable: Continuous run or with thermostat control Configurable: Thermostat Louvered doors with filter, mounting plate, grounding bars, wiring plan pocket, lifting eye bolts on top, bottom cable entry, removable gland plate Equipment/rack room installation (HVAC controlled), 30 C Max. Installation in Safe Area locations; Default Certification: CE (Europe); Optional: None Primary and Secondary 110 VAC Power Supply Rating Internal Power Distribution Local Safety Network Example Layout and Installed Equipment: Fixed 2 x 40A (One set for front & one for rear) AC Distribution subassembly (mounted in left side). Fully redundant 24VDC distribution for CHARM I/O cards and bussed field power through switches and fused terminals (mounted in right side). Redundant 100BASE-FX, RJ45 connectors, to be connected to each CSLS carrier. Primary and Secondary Local Safety Network to 2 CSLS carriers is included. Example BOM: Power Supply subassembly. 5 LS CHARM IO rails, for total of 480 LS I/O, 5 x CSLS Carrier with redundant Copper Ethernet connectors 40 x CHARM Base Plate 40 x CHARM Address Plug 480 x CHARM terminal blocks - Screw type 5 x CHARM I/O bus termination Base Plate and Channel Identifier Labels No DeltaV equipment is included in the base model. All DeltaV equipment is to be configured separately through the Emerson quoting tools. Rear View Size of Wire Baskets: 150mm H x 54mm D 11
12 NA-CAB-800FR-480-AC-CSLS Rear View External Layout Drawing for NA-CAB-800FR-480-AC-CSLS: Front/Rear and. 12
13 Dimensions Access Protection Category IP54 NEMA 12 EU-CAB-800F-192-AC-CSLS 800mm (W) x 600mm (D) x 2000mm (H) + 100mm/200mm Plinth configurable. Front Access single door, right/left hand hinged configurable, latch type lock and 2 sets of keys (key N 3524E) Approximate Weight Color Door Fans Temperature Monitoring Other Environmental Specifications Certifications Input Power ~ 200 kg Cabinet RAL7035, Plinth RAL7022 Configurable: Continuous run or with thermostat control Configurable: Thermostat Louvered doors with filter, mounting plate, grounding bars, wiring plan pocket, lifting eye bolts on top, bottom cable entry, removable gland plate Equipment/rack room installation (HVAC controlled), 30 C Max. Installation in Safe Area locations; Default Certification: CE (Europe); Optional: None Primary and Secondary 230 VAC Power Supply Rating Internal Power Distribution Local Safety Network Example Layout and Installed Equipment: Fixed 2 x 40A AC Distribution subassembly (mounted in left side). Fully redundant 24VDC distribution for CHARM I/O cards and bussed field power through switches and fused terminals (mounted in right side). Redundant 100BASE-FX, RJ45 connectors, to be connected to each CSLS carrier. Primary and Secondary Local Safety Network to 2 CSLS carriers is included. Example BOM: Power Supply subassembly. 2 LS CHARM IO rails, for total of 192 LS I/O, 2 x CSLS Carrier with redundant Copper Ethernet connectors 16 x CHARM Base Plate 16 x CHARM Address Plug 192 x CHARM terminal blocks - Screw type 2 x CHARM I/O bus termination Base Plate and Channel Identifier Labels No DeltaV equipment is included in the base model. All DeltaV equipment is to be configured separately through the Emerson quoting tools. 13
14 EU-CAB-800F-192-AC-CSLS External Layout Drawing for EU-CAB-800F-192-AC-CSLS: Front and. 14
15 Dimensions Access Protection Category IP54 NEMA 12 EU-CAB-800FR-480-AC-CSLS 800mm (W) x 800mm (D) x 2000mm (H) + 100mm/200mm Plinth Configurable. Front Access single door, right/left hand hinged configurable, latch type lock and 2 sets of keys (key N 3524E) Approximate Weight Color Door Fans Temperature Monitoring Other Environmental Specifications Certifications Input Power ~ 300 kg Cabinet RAL7035, Plinth RAL7022 Configurable: Continuous run or with thermostat control Configurable: Thermostat Louvered doors with filter, mounting plate, grounding bars, wiring plan pocket, lifting eye bolts on top, bottom cable entry, removable gland plate Equipment/rack room installation (HVAC controlled), 30 C Max. Installation in Safe Area locations; Default Certification: CE (Europe); Optional: None Primary and Secondary 230 VAC Power Supply Rating Internal Power Distribution Local Safety Network Example Layout and Installed Equipment: Fixed 2 x 40A AC Distribution subassembly (mounted in left side). Fully redundant 24VDC distribution for CHARM I/O cards and bussed field power through switches and fused terminals (mounted in right side). Redundant 100BASE-FX, RJ45 connectors, to be connected to each CSLS carrier. Primary and Secondary Local Safety Network to 2 CSLS carriers is included. Example BOM: Power Supply subassembly. 5 LS CHARM IO rails, for total of 480LS I/O, 5 x CSLS Carrier with redundant Copper Ethernet connectors 40 x CHARM Base Plate 40 x CHARM Address Plug 480 x CHARM terminal blocks - Screw type 5 x CHARM I/O bus termination Base Plate and Channel Identifier Labels No DeltaV equipment is included in the base model. All DeltaV equipment is to be configured separately through the Emerson quoting tools. Rear View 15
16 EU-CAB-800FR-480-AC-CSLS Rear View External Layout Drawing for EU-CAB-800FR-480-AC-CSLS: Front/Rear and. 16
17 How to order a CTO Cabinet? CTO CSLS Cabinets are pre-engineered solutions developed by Emerson s Project Management Office (PMO) and made available from Emerson Supply Chain. Please follow the steps below to configure and order a CTO CSLS Cabinet: 1. Specify the CTO Cabinet by selecting the base model and the options required for the project. A configuration tool is available to aid in the selection of the right combination of optioned CTOs. 2. Based on the specification, you will then receive: A quotation for the fully assembled Cabinet. The detailed specification (drawing package) matching your configuration, including the Bill of Materials. 3. Approve the drawing package for construction. 4. Order the CTO Cabinet as per provided quotation and approved drawings. 5. The CTO Cabinet is assembled, factory tested and delivered to site. The delivery includes the as-built drawing package (AutoCAD). For questions related to specific project quotations or order processing, please contact your local Emerson Sales office or your regional Emerson assembly center: For US/Canada St. Louis icenter: icenterstl.quotes@emerson.com For Europe Cluj icenter: Cabinets.Quotes@Emerson.com For Asia Pacific Singapore icenter: icentersgpquotes@emerson.com Project Customizations What if a CTO Cabinet is 90% what I need, but I really need my Cabinet to have Minor customizations as a variation or addition to the standard CTO offering can often be developed in such a way that the additional effort is incremental. In case your project would require a customer witnessed Factory Acceptance Test, this can also be accommodated. Please work with your local Emerson Sales office or regional Emerson assembly center to evaluate any impacts of requested customizations to cost, delivery time and certifications. System Compatibility CSLS Cabinets are compatible with DeltaV version 12.3 and above CSLS cards require DeltaV SZ Controllers Certifications The CTO CHARMs Cabinet designs are designed to meet CE and CSA personal safety and EMC requirements. The designs have been submitted for the following certifications: Conformity to the relevant European directives, including EMC (CE Marking) CSA Mark for US and Canada For Europe Design Standards and Regulations, the cabinet default comes with CE Certification. Optionally, no certification can be specified. For US/Canada Design Standards and Regulations, the cabinet default does not come with certification. The CSA Certification is optional. Refer to the DeltaV SIS with Electronic Marshalling or to the DeltaV SIS with IS Electronic Marshalling Product Data Sheet for certification information on the DeltaV SIS system components. 17
18 Related Products CSLS cards must be ordered separately LS CHARMs must be ordered separately LS CHARMS requiring other terminal blocks than the standard terminal block should be ordered with the non-standard terminal block Emerson North America, Latin America: or Asia Pacific: Europe, Middle East: , Emerson. All rights reserved. The Emerson logo is a trademark and service mark of Emerson Electric Co. The DeltaV logo is a mark of one of the Emerson family of companies. All other marks are the property of their respective owners. The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available on request. We reserve the right to modify or improve the designs or specifications of our products at any time without notice.
CTO Server and Network Cabinets
DeltaV Distributed Control System Product Data Sheet January 2018 CTO Server and Network Cabinets CTO Server and Network Cabinet. Delivers standard cabinet with 19 frame construction for your DeltaV networking
More informationCTO Cabinets. Introduction. Delivers Electronic Marshalling enabled by CHARMs technology or controller cabinet for CHARM system.
DeltaV Distributed Control System Product Data Sheet November 2017 CTO Cabinets Delivers Electronic Marshalling enabled by CHARMs technology or controller cabinet for CHARM system Fast delivery Reduced
More informationCTO CSLS Field Enclosure
DeltaV SIS Process Safety System Product Data Sheet CTO CSLS Field Enclosure Delivers Electronic Marshalling enabled by CHARacterization Module (CHARM) technology Reduce system footprint Eliminate I/O
More informationCTO CHARM Field Enclosure
DeltaV Distributed Control System Product Data Sheet November 2017 CTO CHARM Field Enclosure Configure to Order (CTO) CHARM Field Enclosures. Delivers Electronic Marshalling enabled by CHARacterization
More informationS-series Horizontal Carriers
DeltaV Distributed Control Systems Product Data Sheet S-series Horizontal Carriers The DeltaV modular I/O subsystem is easy to install and maintain Modular design allows flexible installation Allows you
More informationDeltaV Electronic Marshalling for Migrations
DeltaV Distributed Control System Product Data Sheet DeltaV Electronic Marshalling for Migrations I/O anywhere you need it Single channel granularity Replaces legacy I/O in place Fully redundant architecture
More informationDeltaV SX Controller. Introduction. Benefits. Scalable controllers. Quick assembly. Easy to use. Field proven architecture
DeltaV Distributed Control System Product Data Sheet January 2018 DeltaV SX Controller Scalable controllers Quick assembly Easy to use Field proven architecture Designed for Electronic Marshalling Advanced
More informationDeltaV SQ Controller. Introduction. Benefits. Scalable controllers. Quick assembly. Easy-to-use. Field proven architecture
DeltaV Distributed Control System Product Data Sheet January 2018 DeltaV SQ Controller Scalable controllers Quick assembly Easy-to-use Field proven architecture Designed for Electronic Marshalling Advanced
More informationDeltaV M-series I/O Subsystem Horizontal Carriers
DeltaV Distributed Control System Product Data Sheet DeltaV M-series I/O Subsystem Horizontal Carriers The DeltaV modular I/O subsystem is easy to install and maintain. Modular design allows flexible installation
More informationFree Standing DeltaV Double Door Cabinet
May 2007 Page 1 Free Standing DeltaV Double Door Cabinet Minimized design costs Decreased delivery time Decreased material and labor costs through standardized approach Decreased quotation time Introduction
More informationS-series Electronic Marshalling for Migrations
March 2013 Page 1 S-series Electronic Marshalling for Migrations S-series CHARM I/O Cards (CIOC) mounted on a Migration Panel S-series CHARM I/O Baseplate Migration Panel. I/O anywhere you need it Single
More informationS-series Horizontal Carriers
January 2013 Page 1 The DeltaV modular I/O subsystem is easy to install and maintain Modular design allows flexible installation Allows you to expand online Integrated power distribution Snap in assembly
More informationDeltaV Bulk Power Supplies
DeltaV Distributed Control System Product Data Sheet DeltaV Bulk Power Supplies DeltaV 5 A, 10A, 20 A, 40 A Bulk Power Supplies. DeltaV 20 A, 40 A and 80 A Bulk Power Supply Redundancy Modules. Easy to
More informationDeltaV SX Controller. DeltaV SX Controller. Introduction. DeltaV Product Data Sheet. Scalable controllers. Quick Assembly.
August 2010 Page 1 The and the DeltaV I/O subsystem make rapid installation easy Scalable controllers Quick Assembly Easy to use Field Proven architecture Designed for Digital Marshalling Advanced Controls
More informationDeltaV SIS Conditioning Components
DeltaV SIS Process Safety System DeltaV SIS Conditioning Components The DeltaV SIS conditioning components allow you to use the DeltaV SIS system with a variety of different field signal requirements.
More informationDeltaV SD Plus Controller
August 2010 Page 1 The and the DeltaV I/O subsystem make rapid installation easy Scalable controllers Quick Assembly Easy to use Field Proven architecture Designed for Digital Marshalling Advanced Controls
More informationDeltaV VerticalPlus I/O Subsystem Carriers
DeltaV Distributed Control System Product Data Sheet DeltaV VerticalPlus I/O Subsystem Carriers Designed for SIS Modular design allows flexible installation Allows you to expand online Increases I/O density
More informationFree Standing DeltaV Single Door Cabinet
May 2007 Page 1 Minimized design costs Decreased delivery time Decreased material and labor costs through standardized approach Decreased quotation time Introduction DeltaV cabinets are designed to be
More informationDeltaV Bulk Power Supplies
DeltaV Distributed Control System Product Data Sheet DeltaV Bulk Power Supplies DeltaV 5 A, 10A, 20 A, 40 A Bulk Power Supplies. DeltaV 20 A, 40 A and 80 A Bulk Power Supply Redundancy Modules. Easy to
More informationS-series Mass Connection Solutions
DeltaV Distributed Control System Product Data Sheet August 2017 S-series Mass Connection Solutions Fast, easy and error-free cabinet wiring Modular design, improves reliability Lowers overall termination
More informationDeltaV MX Controller. Introduction. Benefits. Right-sized controllers. Easy to use. Has the flexibility to meet your needs
DeltaV Distributed Control System Product Data Sheet October 2017 DeltaV MX Controller Right-sized controllers Easy to use Has the flexibility to meet your needs Designed to support legacy migration Introduction
More informationDeltaV SIS with Electronic Marshalling - Virtual Simulation
DeltaV Safety Instrumented System Product Data Sheet September 2017 DeltaV SIS with Electronic Marshalling - Virtual Simulation The DeltaV SIS system provides the ability to virtualize hardware components
More informationDeltaV MQ Controller. Introduction. Benefits. Increases productivity. Easy to use. Has the flexibility to meet your needs. Increases productivity
DeltaV Distributed Control System Product Data Sheet October 2017 DeltaV MQ Controller Increases productivity Easy to use Has the flexibility to meet your needs Introduction The MQ Controller provides
More informationS-Series DeltaV Controller Interface for PROVOX I/O
DeltaV Distributed Control System Product Data Sheet S-Series DeltaV Controller Interface for PROVOX I/O The S-Series DeltaV Controller Interface for PROVOX I/O. I Provides a fast and easy upgrade for
More informationM-series Intrinsically Safe I/O
DeltaV Distributed Control System Product Data Sheet M-series Intrinsically Safe I/O Features full system modularity Reduces system footprint Decreases installation time and expense Plug-and-play installation
More informationIntroduction. Delivers four ports to provide increased input/ output per card. Takes advantage of all smart device capabilities
DeltaV Distributed Control System M-series Foundation TM Fieldbus Product Data Sheet Series 2 Plus I/O Use DeltaV state-of-the-art Foundation Fieldbus Series 2 Plus redundant I/O for your process control
More informationDeltaV PK Controller. Benefits. Introduction. Powerful Standalone. Easily Integrated. Fast process control applications
DeltaV Distributed Control System Product Data Sheet February 2018 DeltaV PK Controller Powerful Standalone. Easily Integrated. Fast process control applications Designed for use with any DeltaV I/O family
More informationS-series DeviceNet Interface Card
DeltaV Distributed Control System Product Data Sheet S-series DeviceNet Interface Card The DeltaV S-series DeviceNet Interface Card provides the solution for interfacing to discrete actuators and sensors.
More informationM-series MQ Controller
DeltaV Distributed Control System Product Data Sheet M-series MQ Controller Increases productivity Easy to use Has the flexibility to meet your needs Introduction The MQ Controller provides communication
More informationSmart Commissioning. White Paper February 2018
Smart Commissioning Smart Commissioning is a technology-enabled approach for streamlining the commissioning of field instrumentation connected to a DeltaV Distributed Control System (DCS) or Safety Instrumented
More informationM-series MX Controller
DeltaV Distributed Control System Product Data Sheet June 2017 M-series MX Controller Right-sized controllers Easy to use Has the flexibility to meet your needs Designed to support legacy migration Introduction
More informationM-series I/O Subsystem Horizontal Carriers
February 2016 Page 1 DeltaV M-series I/O Subsystem Horizontal Carriers DeltaV M-series I/O Subsystem Horizontal Carriers The DeltaV modular I/O subsystem is easy to install and maintain. Modular design
More informationS-series Foundation Fieldbus I/O
DeltaV Distributed Control System Product Data Sheet S-series Foundation Fieldbus I/O Use DeltaV state-of-the-art S-series FOUNDATION fieldbus I/O for your process control system. Increase I/O capacity
More informationS-series Sequence of Events Card
DeltaV Distributed Control Systems Product Data Sheet S-series Sequence of Events Card DeltaV Sequence of Events delivers high-resolution data capture for your easy analysis. Captures process upset events
More informationDeltaV Control Network Hardware
DeltaV Distributed Control System Product Data Sheet January 2018 DeltaV Control Network Hardware Easy to use Scalable and cost-effective Built-in network diagnostics Fully redundant network The DeltaV
More informationM-series Foundation Fieldbus I/O
DeltaV Distributed Control System Product Data Sheet M-series Foundation Fieldbus I/O Use DeltaV state-of-the-art FOUNDATION Fieldbus redundant I/O for your process control system. Increases input/output
More informationSmart Commissioning. White Paper January 2019
is a technology-enabled approach for streamlining the commissioning of field instrumentation connected to a DeltaV Distributed Control System (DCS) or Safety Instrumented System (SIS). It reduces the effort
More informationM-series Profibus DP Series 2 Plus Interface Card
DeltaV Distributed Control Systems Product Data Sheet M-series Profibus DP Series 2 Plus Interface Card The DeltaV M-series Profibus DP Interface Card provides the solution for interfacing to discrete
More informationUse of Cisco Switches on the DeltaV Area Control Network (ACN)
DeltaV Distributed Control System White Paper December 2018 Use of Cisco Switches on the DeltaV Area Control Network (ACN) This document explains the specific use cases where approved Cisco switches can
More informationGE Measurement & Control. Packaged Systems. Bently Nevada * Asset Condition Monitoring
GE Measurement & Control Packaged Systems Bently Nevada * Asset Condition Monitoring Complete System Enclosure Packages In about the same time it takes to deliver unconfigured monitoring racks and components,
More informationM-series DC to DC Power Supply
February 2016 Page 1 M-series DC to DC Power Supply Enhanced The DeltaV M-series Enhanced DC/DC system power supplies are modular, easy to install, and secure Easy to use Flexible and cost-effective Secure
More informationDeltaV Safety Instrumented System (SIS) with Electronic Marshalling
DeltaV SIS Process Safety System Product Data Sheet DeltaV Safety Instrumented System (SIS) with Electronic Marshalling Optimized process reliability Simplified safety lifecycle management Flexibility
More informationVERAK IP. 19 Stand Alone Cabinet with IP65 Rating.
19 Stand Alone Cabinet with IP65 Rating www.apw.eu.com Overview Material specification Frame: Steel 2.0 mm Panel mounting angles and reducing channels: Steel 2.0 mm Panel mount supports: Steel 1.5 mm Side
More informationS-series H1 I/O Card with Integrated Power
January 2013 Page 1 S-series H1 I/O Card with Integrated Power Use DeltaV state-of-the-art for your process control system. Increase I/O capacity while reducing wiring Maximize smart device capabilities
More informationEthernet I/O Card. Ethernet I/O Card. Introduction. DeltaV Product Data Sheet. Easy to use. Powerful integration solution. Modular, flexible packaging
August 2010 Page 1 The Ethernet IO Card provides a high speed Ethernet IO device integration platform Easy to use Powerful integration solution Modular, flexible packaging Introduction The DeltaV S-Series
More informationRoxar CorrLog High Accuracy Corrosion Monitoring
FA-T200-C Product Data Sheet 01.12.2016 High Accuracy Corrosion Monitoring Fast and reliable corrosion monitoring is a key for efficient corrosion management and control. In-line corrosion monitoring provides
More informationM-series DeltaV Controller Interface for PROVOX I/O
January 2013 Page 1 M-series DeltaV Controller Interface for PROVOX I/O PROVOX I/O Interface Modules DeltaV Railbus C Control I/O Bus with Redundant Connections Upgrade your PROVOX controllers with the
More informationS-series Electronic Marshalling
April 2013 Page 1 S-series Electronic Marshalling The DeltaV CHARM I/O Card (CIOC) with CHARMs I/O anywhere you need it Single channel granularity Reduces installed cost of system Fully redundant architecture
More informationPlatform. Product Data Sheet PDS A01 January, 2004 NGA 2000
Product Data Sheet PDS 103-610.A01 January, 2004 NGA 2000 Platform Modular design single platform supports multiple analyzer and Input/Output modules Local network with intelligent, bi-directional communication
More informationAgilent U8000 Series Single Output DC Power Supplies. Data Sheet
Agilent U8000 Series Single Output DC Power Supplies Data Sheet Key Features Excellent load and line regulation: (CV:
More informationRoxar SandLog High Accuracy Sand/Erosion Monitoring
FA-T201-C Product Data Sheet 01.12.2016 High Accuracy Sand/Erosion Monitoring The effective management of sand is important for the integrity of oil and gas assets and for optimizing production. Together
More informationEUROTHERM PRO ESS AUTOMATION NETWORK. T754X series control enclosures. Product Specification
6000 EUROTHERM PRO ESS AUTOMATION NETWORK T754X series control enclosures Product Specification HIGH AVAILABILITY PROCESS CONTROL ENCLOSURE Capacity 512 I/O points based on T103/T303 control units Redundant
More informationPower-Style QED-2, Series 2 Low Voltage Switchboards
Power-Style QED-2, Series 2 Low Voltage Switchboards Catalog 2742CT1001 (Addendum to 2742CT9501R12/09) 2010 Class 2742 CONTENTS Description............................................. Page Features...................................................
More informationS-series DeviceNet Interface Card
January 2013 Page 1 The DeltaV provides the solution for interfacing to discrete actuators and sensors. Offers freedom to choose appropriate bus for application Supports standard device-level busses Reduces
More informationDeltaV Simulate. Introduction. Product Data Sheet April DeltaV Distributed Control System
DeltaV Distributed Control System Product Data Sheet April 2017 DeltaV Simulate Allows DeltaV configuration on a single PC or in a multi-node system Provides integrated simulation of control system (BPCS)
More informationFP-PS-4. Features. Installation
OPERATING INSTRUCTIONS FP-PS-4 FieldPoint Power Supply These operating instructions describe the installation, features, and characteristics of the FP-PS-4. Features The FP-PS-4 is a FieldPoint power supply
More informationElectrical Demand Specification (Reference SOP: )
Project: Equipment Description: Location: Equipment No.: Project No: Protocol No.: Content Index 1. GENERAL...3 Design Standards...3 1.1. Standards...3 2. DESIGN...3 2.1. Safety...3 2.2. Circuit protection...3
More informationForm C contact for remote monitoring UL 1449, UL 1283, cul recognized component, CE 5 Year Limited Warranty
DIN RAIL MOUNTED ACTIVE TRACKING FILTERS WITH SURGE PROTECTION maximize protection STFE Elite Series Active tracking filter with surge protection Features Series connected DIN Rail mounted filter Patented
More informationForm C contact for remote monitoring UL 1449, UL 1283, cul recognized component, CE 5 Year Limited Warranty
DIN RAIL MOUNTED ACTIVE TRACKING FILTERS WITH SURGE PROTECTION maximize protection STFE Elite Series Active tracking filter with surge protection Features Series connected DIN Rail mounted filter Patented
More informationFast Control Response Requirement
DeltaV Distributed Control System White Paper October 2016 Fast Control Response Requirement This document describes how fast loop control is achieved by using FOUNDATION Fieldbus with Control in the Field.
More informationS-series Profibus DP Interface Card
January 2013 Page 1 The DeltaV provides the solution for interfacing to discrete actuators and sensors. Integrates Profibus DP device signals directly into control logic Reduces wiring costs Native bus
More informationConfiguration Software Suite
DeltaV Distributed Control System Product Data Sheet Configuration Software Suite Configuration Software Suite is an integrated, modular, and graphical approach to system configuration. Simple, automatic
More informationTRC-190 User s Manual
User s Manual Edition 3.2, May 2017 www.moxa.com/product 2017 Moxa Inc. All rights reserved. User s Manual The software described in this manual is furnished under a license agreement and may be used only
More informationVC3000 Series Line Voltage Switching Relay Pack Controllers Installation Guide
Beyond Comfort VC3000 Series Line Voltage Switching Relay Pack Controllers Installation Guide August 10 th, 2010 (For Commercial and Lodging HVAC Fan Coil Applications) 028-0296-R1-LIT-VC3000-E01 Index
More informationOvation Controller Model OCR1100
Ovation Controller Model OCR1100 Features Secure, reliable and mission-critical control capability providing bumpless automatic failover between redundant controllers. Fast processor for increased productivity
More informationRoom unit with PPS2 interface
1 642 Desigo RX Room unit with PPS2 interface for use with: QAX33.1 devices of the ranges Desigo RXC, RXB, RXL, and RXA (PPS2) Desigo PX Automation stations 1) devices with a PPS2 interface Room temperature
More informationM-series DeltaV Controller Interface for RS3 I/O
January 2013 Page 1 M-series DeltaV Controller Interface for RS3 I/O RS3 I/O Interface Modules DeltaV Railbus Connection RS3 I/O Interface Carrier RS3 I/O Connectors (8) Upgrade your RS3 ControlFiles with
More informationKeysight Technologies E3620A and E3630A Non-programmable DC Power Supplies. Data Sheet
Keysight Technologies and E3630A Non-programmable DC Power Supplies Data Sheet 02 Keysight and E3630A Non-programmable DC Power Supplies Data Sheet Reliable Power, Repeatable Results Linear power supply
More informationCisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2
Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2 Cisco CRS 3-Phase AC Power Distribution Unit 2 Revised: November 18, 2016,
More informationDPS SERIES DC POWER SUPPLIES
DPS SERIES: 15kW - 60kW Key features: 15kW to 60kW Models Higher Power Configurations Available 3U Compact Form Factor Voltage Ranges up to 1200 Vdc Current Ranges up to 3000 Adc High-Speed Precision Metering
More informationOvation Compact Controller
Ovation Compact Controller Model OCC100 Features Secure, reliable and mission-critical control capability for remotely located plants or processes Modular I/O base design for flexible placement within
More informationThis Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount.
This Datasheet for the IC697CHS790 Rack, 9 Slots, Rear Mount. http://www.cimtecautomation.com/parts/p-14771-ic697chs790.aspx Provides the wiring diagrams and installation guidelines for this GE Series
More informationCONTROL PANEL WIRING SPECIFICATIONS
CONTROL PANEL WIRING ISSUE STATUS FIRST REV DESCRIPTION DATE 001 1 ST ISSUE 22/04/2014 002 1 ST AMMENDMENT 10/03/2017 003 2 ND AMMENDMENT 08/09/2017 THIS DOCUMENT IS DESIGNED TO COVER ALL APPLICATIONS,
More informationVertiv VR Rack 1.0 GENERAL
1.1 SUMMARY Vertiv VR Rack Guide Specifications 1.0 GENERAL This specification defines the mechanical characteristics and requirements for the Vertiv VR Rack. A series of adaptive and scalable electronic
More informationLASERMET SLIMJIM LED SIGN INSTRUCTION MANUAL LEDS-SJ XXX
LASERMET SLIMJIM LED SIGN INSTRUCTION MANUAL LEDS-SJ 00843-00-XXX 00843-53-000 Page 1 of 11 Issue 3 2 January 2013 Lasermet SlimJim Illuminated Sign Instruction Manual Contents Introduction... 4 Installation...
More informationS-series Electronic Marshalling
DeltaV Distributed Control System Product Data Sheet July 2017 S-series Electronic Marshalling I/O anywhere you need it Single channel granularity Reduces installed cost of system Fully redundant architecture
More informationDeltaV SIS TM. Logic Solver. DeltaV SIS Logic Solver. Introduction. DeltaV SIS Product Data Sheet. World s first smart SIS Logic Solver
February 2016 Page 1 DeltaV SIS TM Logic Solver The DeltaV SIS platform is the world s smart SIS system to use the power of predictive intelligence for increasing the availability of the entire safety
More informationRTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions
Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS PRODUCT DESCRIPTION ARTICLE CODES INTENDED AREA OF USE TECHNICAL DATA STANDARDS OPERATIONAL DIAGRAMS WIRING AND CONNECTIONS
More informationF101, F102, F104. Relcom Installation Instructions. Fieldbus Power Supply F101-PS
F101, F102, F104 Fieldbus Power Supply F101-PS Installation Instructions Relcom www.mtl-fieldbus.com CONTENTS PAGE 1 OVERVIEW 2 2 DESCRIPTION 2 3 COMPONENTS AND ACCESSORIES 2 4 MECHANICAL 3 4.1 Mounting
More informationS-series IS Electronic Marshalling
DeltaV Distributed Control System Product Data Sheet S-series IS Electronic Marshalling Intrinsically Safe I/O anywhere you need it Integrated galvanic Isolation per channel Reduces installed cost of system
More informationDeltaV Ethernet I/O Card
DeltaV Distributed Control System Product Data Sheet October 2017 DeltaV Ethernet I/O Card Powerful solution that communicates directly to external Ethernet Device Networks Easy connection to devices using
More informationISASecure SSA Certification for DeltaV and DeltaV SIS
ISASecure SSA Certification for DeltaV and DeltaV SIS Frequently Asked Questions This FAQ addresses questions around the scope and relevance of the ISASecure System Security Assurance certification applied
More informationE-Series Site Preparation Guide
E-Series Site Preparation Guide September 2017 215-11797_A0 doccomments@netapp.com Table of Contents 3 Contents Deciding whether to use this guide... 10 Specifications of the model 3040 40U cabinet...
More information4C Standard Horizontal Mailboxes
4C Standard Horizontal Mailboxes Note: 3700 series 4C standard horizontal mailboxes and parcel lockers have been U.S.P. S. approved and meet the specifications of USPS-STD-4C. These units are required
More informationConfiguration Software Suite
DeltaV Distributed Control System Product Data Sheet Configuration Software Suite Configuration Software Suite is an integrated, modular, and graphical approach to system configuration. Simple, automatic
More informationKUANTECH (SHEN ZHEN) COMPANY LIMITED KSAFD W1UK
1 GENERAL... 2 1.1 Description... 2 2 INPUT REQUIREMENTS... 2 2.1 Input Conditions... 2 2.2 AC Inrush Current... 2 3 OUTPUT REQUIREMENTS... 2 4 MECHANICAL... 3 4.1 Enclosure And Layout... 3 4.2 Input and
More informationHCS Newsletter No. 43, Dated Thursday, 04 December, 2003 HCS DataLine Cabinets and Enclosures
HCS - Made in Turkey With Pride! HCS Newsletter No. 43, Dated Thursday, 04 December, 2003 HCS DataLine Cabinets and Enclosures HCS, the only Turkish manufacturer of state-of-the-art LAN cabling systems
More informationAgilent E36XXA Series Non-Programmable DC Power Supplies. Data Sheet
Agilent E36XXA Series Non-Programmable DC Power Supplies Data Sheet Reliable Power, Repeatable Results Linear power supply Single, dual or triple output 10-turn voltage and current control Low noise and
More informationQAX50.1 QAX50.5 QAX51.1 QAX51.5. Flexible room unit. Desigo RXC
1 648 Desigo RXC Flexible room unit for integrated operation of HVAC, lighting and blinds in individual rooms; with LONMARK -compatible bus communication QAX50.1 QAX50.5 QAX51.1 QAX51.5 Room temperature
More informationSED2 VFD NEMA Type 3R Bypass/Air Conditioner
SED2 VFD NEMA Type 3R Bypass/Air Conditioner Description The NEMA Type 3R Bypass with Air Conditioner allows SED2 to be employed in a harsh environment. The SED2 is designed specifically for HVAC applications
More informationAgilent 66000A 1200 W DC Modular Power System, GPIB
Agilent 66000A 1200 W DC Modular Power System, GPIB Data Sheet Speed and accuracy for test optimization 8-slot mainframe accepts up to 8 DC power modules 1200 W total DC power output, up to 150 W per module
More informationSECTION ( ) LIGHTING CONTROL PANELBOARD
(26 24 16.02) LIGHTING CONTROL PANELBOARD PART 1 GENERAL 1.01 SCOPE A. The Contractor shall furnish and install Lighting Control Panelboards as specified and as shown on the contract drawings. B. The Lighting
More informationEMEA. Product Catalog. RackLine. AT&T Rack & Enclosure LAN Cabling Products. AT&T Cabling Systems
EMEA Product Catalog 2014 AT&T Rack & Enclosure LAN Cabling Products AT&T Cabling Systems provide complete enterprise solutions and state-of-the-art LAN cabling components for all needs. AT&T Cabling Systems
More informationPD-6506, PD & PD-6524
PD-6506, PD-6512 & PD-6524 User Guide Notice The information contained herein is believed to be accurate and reliable at the time of printing. However, due to ongoing product improvements and revisions,
More informationM-series Profibus DP Series 2 Plus Interface Card
January 2013 Page 1 M-series Profibus DP Series 2 Plus Interface Card The DeltaV M-series Profibus DP Interface Card provides the solution for interfacing to discrete actuators and sensors. Offers freedom
More informationSUPERVISORY CONTROL AND DATA ACQUISITION SYSTEM (SCADA)
TECHNICAL SPECIAL PROVISION FOR SUPERVISORY CONTROL AND DATA ACQUISITION SYSTEM (SCADA) FINANCIAL PROJECT NO.: 428213-2-52-02 MARION COUNTY The official record of this Technical Special Provision is the
More informationAgilent E363xA Series Programmable DC Power Supplies. Data Sheet
Agilent E363xA Series Programmable DC Power Supplies Data Sheet Reliable Power, Repeatable Results Single and triple output 80 W to 200 W output power Dual range output Low noise and excellent regulation
More informationPower Enclosure Components
Power Enclosure Components HP BladeSystem p-class 1U Power Enclosure Exploded View Figure 1-5 HP BladeSystem p-class 1U power enclosure exploded view Illustrated Parts Catalog 20 HP BladeSystem p-class
More informationFLEX Ex Spring Clamp Terminal Base
Installation Instructions FLEX Ex Spring Clamp Terminal Base (Cat. No. 1797-TB3S) 1 10 11 4 Only remove this cover plug if connecting another terminal base unit. 3 5 6 12 2 7 8 9 41253 Component Identification
More informationSustain.Ability Honeywell Users Group EMEA. Adriano Canale How Universal I/O Can Help Save Design Cost and Project Execution Time
Sustain.Ability. 2012 Honeywell Users Group EMEA Adriano Canale How Universal I/O Can Help Save Design Cost and Project Execution Time Customer Needs Challenges: - Project becoming increasingly complex
More information