Technical Datasheet clima BSK4-F / BSK4-F230 NK mêççìåí=çéëåêáéíáçå
|
|
- Ursula Carroll
- 6 years ago
- Views:
Transcription
1 Technical Datasheet clima BSK4-F / BSK4-F230 NK mêççìåí=çéëåêáéíáçå The modules clima BSK4-F and clima BSK4-F230 are used as actuators to integrate up to 4 fire dampers or smoke dampers with spring return drive into LON networks. The difference between both types of modules is the type of power supply. The module clima BSK4-F is supplied with 24V AC or DC, the module clima BSK4-F230 is mains-operated (230V AC). The damper motors could be directly connected to the terminal blocks of the modules. Both modules support a monitoring of 8 potential-free end-position switches. LED indicators provide a status information about the actual status of the end-position switches and therefore the damper position. The switch outputs can drive the damper motors to set the damper in normal position. The application provides for each connected damper a functional block according to LonMark profile FireSmokeDamperActuator (#11001_10). The current damper position is transferred via the LON-network. A damper maintenance routine is integrated in the application. By measuring the damper driving time which is needed to move from one end-position to the other, mechanical failures could be easily detected. The application provides detailed alarm messages regarding triggered fire alarms of damper malfunction. Those messages can be signalled to a building management system via the LON network. Version Page 1 of 7 04/03/2012
2 OK jçìåíáåö=~åç=áåëí~ää~íáçå= OKNK jçìåíáåö The installation of the input module is in hollow floors, suspended ceilings or directly to ventilation ducts. The existing mounting points can be found in the following figure: The device is designed for safety extra low voltage (SELV). Installation and assembly of electrical equipment must be carried out only by qualified electricians! Please observe local standards, guidelines and regulations when planning and installing electrical devices. Operate the device only within its specifications. The included cable entries provide a IP65 degree of protection with adequate strain relief. To increase the strain relief alternatively cable glands can be used. Version Page 2 of 7 04/03/2012
3 OKOK fåëí~ää~íáçå Installation and assembly of electrical equipment must be carried out only by qualified electricians! The binary inputs are only suitable for connections to potential-free contacts. The binary inputs fulfil Safety Extra Low Voltage (SELV) requirements. `çååéåíáçå=çñ=åäáã~=_phqjc The module clima BSK4-F provides a TP/FT-10 transceiver to connect to a freeology LON network. The module is supplied by 24V AC or DC. The module power supply is identical to the motor supply. Please use the following connection diagram: 24V AC/DC LON A/B BSK 1 M M BSK E1.1 E1.2 E2.1 E2.2 M1M1 M2 M2 LON A B A B <-24V E3.1 E3.2 E4.1 E4.2 M3M3 M4 M BSK 3 M M BSK 4 If dampers with two end-position switches are used, connect them to two adjacent binary inputs. For the (open) -position is the lower sub-number (e.g. E1.1) input to be used and the position (close) -position is to be connected to the higher sub-number (e.g. E1.2). Version Page 3 of 7 04/03/2012
4 If dampers with one end-position switches are used or if only one position should be monitored, use one binary input for each position switch. The number of switches (1 or 2) of one damper can be configured for each damper object in the LON application. `çååéåíáçå=çñ=åäáã~=_phqjcopm The module clima BSK4-F230 provides a TP/FT-10 transceiver to connect to a free- ology LON network. The module is supplied by 230V AC. The module power supply is identical to the motor supply. Please use the following connection diagram: 230V AC L N PE LON A/B BSK 1 M M BSK 2 L L LON A B A B E1.1 E1.2 E2.1 E2.2 M1M1 M2 M2 PEPEPEPEPEPE <-230V-> E3.1 E3.2 E4.1 E4.2 M3M3 M4 M4 N N N N N N BSK 3 M M BSK 4 If dampers with two end-position switches are used, connect them to two adjacent binary inputs. For the (open) -position is the lower sub-number (e.g. E1.1) input to be used and the position (close) -position is to be connected to the higher sub-number (e.g. E1.2). If dampers with one end-position switches are used or if only one position should be monitored, use one binary input for each position switch. The number of switches (1 or 2) of one damper can be configured for each damper object in the LON application. Version Page 4 of 7 04/03/2012
5 PK qéåüåáå~ä=ç~í~ Åäáã~=_phQJc Operating voltage Current input 24V AC/DC max. 180 ma Type of network TP/FT-10 (78kbps) Type of transceiver FTT 10 Inputs / outputs Relay outputs Terminals Motor outputs Control elements Service push-button Motor-relay push-button Display elements Service LED LED status indicators 8 inputs for potential-free contacts, contact supply 24V DC, 5mA current 4 motor relays. Max. 50W for a DC-3 or DC-5 type load or max. 250W for a AC-3 type load each motor output for dampers with spring return drive. Motor supply is identical to module power supply. 2 integrated fuses, shared for two motor outputs respectively 1 x 2-pole (+) and 1 x 6-pole (-) clamp terminal 1 x 4-pole clamp terminal 2 x 8-pole clamp terminal for 8 inputs each 2 x 4-pole clamp terminal for connection of 4 motors Sends Neuron-ID when pressed 1 push-button per relay for manual relay output for manual control Device status Status of binary inputs Housing Type of protection IP 65 (DIN / IEC 144) Dimensions 63 x 254 x 180 mm (h x w x d) Type/location of installation Assembly on ventilation ducts, in hollow floors, suspended ceilings Ambient conditions Operating temperature -5 C C Transportation temperature -25 C C Rel. humidity -25 C C Installation height 5%...93% (without condensation) Ambient conditions bis 2000 m above sea level Safety Electrical insulation SELV (EN ) Insulation class III (IEC 536 / VDE 106 part 1) Standards/guidelines EN :1996 EN /A1:2002 EN /A2:2007 CE Version Page 5 of 7 04/03/2012
6 Åäáã~=_phQJcOPM Operating voltage Current input 230V AC max. 4,5 VA Type of network TP/FT-10 (78kbps) Type of transceiver FTT 10 Inputs Relay outputs Terminals Motor outputs Control elements Service push-button Motor-relay push-button Display elements Service LED LED status indicators 8 inputs for potential-free contacts, contact supply 24V DC, 5mA current 4 motor relays. Max. 250W (AC-3 type load) each motor output for dampers with spring return drive. Motor supply is identical to module power supply 2 integrated fuses, shared for two motor outputs respectively 1 x 2-pole und 2 x 6-pole clamp terminal (6xL, 2xPE, 6xN) 1 x 4-pole clamp terminal 2 x 8-pole clamp terminal for 8 inputs each 2 x 4-pole clamp terminal for connection of 4 motors Sends Neuron-ID when pressed 1 push-button per relay for manual relay output for manual control Device status Status of binary inputs Housing Type of protection IP 65 (DIN / IEC 144) Dimensions 63 x 254 x 180 mm (h x w x d) Type/location of installation Assembly on ventilation ducts, in hollow floors, suspended ceilings Ambient conditions Operating temperature -5 C C Transportation temperature -25 C C Rel. humidity -25 C C Installation height 5%...93% (without condensation) Ambient conditions bis 2000 m above sea level Safety Electrical insulation SELV (EN ) Insulation class II (IEC 536 / VDE 106 part 1) Standards/guidelines EN :1996 EN /A1:2002 EN /A2:2007 EN CE Version Page 6 of 7 04/03/2012
7 QK mêççìåíë QKNK lêçéê=áåñçêã~íáçå Order number Description C clima BSK4-F LON fire damper actuator 4 ports for external 24V power supply C clima BSK4-F230 LON fire damper actuator 4 ports with integrated 230V power supply RK pìééçêí The information given in this manual has been carefully collated. Should you have any further questions relating to this product, please contact: spega - Spelsberg Gebäudeautomation GmbH Zechenstr. 70 D Moers Fon: +49 (2841) Fax: +49 (2841) support@spega.de Version Page 7 of 7 04/03/2012
Technical Datasheet clima RCM-CC
Technical Datasheet 1. Product description The is a room control panel with an integrated temperature sensor for measuring the room temperature. The device is featured with a turn wheel to adjust the set
More informationTechnical Datasheet clima RCM-FC 1. Product description
Technical Datasheet 1. Product description The is a room control panel with an integrated temperature sensor for measuring the room temperature. The device is featured with a turn wheel to adjust the set
More informationQXA2000 QXA2001. Condensation Monitor QXA2001 QXA2000 AQX2000
1 542 1542P03 1542P01 1542P02 QXA2001 QXA2000 AQX2000 Condensation Monitor QXA2000 QXA2001 The QXA2000 condensation monitor is used to avoid damage due to condensation on chilled ceilings and in HVAC plant.
More informationUser Manual LON MSeries. Moers, 22/01/2013. Version
User Manual LON MSeries User Manual LON MSeries Version 1.11 Moers, Page 1 of 237 User Manual LON MSeries Content 1. Introduction...4 1.1. 1.2. 2. Product description...6 2.1. 2.2. 2.3. 2.4. 2.5. 2.6.
More informationDecentralised operating and monitoring systems
MB-BAC-WA 1/4.3 X X MB-BAC-WA 1/4 testregistrierung Decentralised operating and monitoring systems Type MB-BAC-WA 1/4 Communication interface for exchanging variables via BACnet or Modbus Functional modules
More informationOperating instructions AS-i SmartLine module AC3200 AC /00 06/2016
Operating instructions AS-i SmartLine module AC3200 AC3201 80237876/00 06/2016 Contents 1 Preliminary note...3 1.1 Symbols used...3 1.2 Warnings used...3 2 Safety instructions...3 2.1 General...3 2.2 Target
More informations Spring return C / max C
echnical data sheet SF4A actuator for WORKS with emergency function for adjusting air dampers in ventilation and air conditioning systems in buildings For air dampers up to approx. 4 m orque 0 Nm Nominal
More informationProduct and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005
Product and Applications Description Application Programs The application programs of the dimmer UP 525/01 consist of two elements: the actuating and the sensor program element. The tasks actuating program
More informationProduct and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs
Product and Applications Description Example of Operation dimmer UP 525/11 load circuit AC 230 V L1 N The dimmer UP 525/11 is a dimming actuator for mounting in box mounts (a.o. 60 mm Ø, 60 mm depth).
More informationQUINT-PS/ 1AC/24DC/ 5
Extract from the online catalog QUINT-PS/ 1AC/24DC/ 5 Order No.: 2866750 DIN rail power supply unit 24 V DC/5 A, primary switched-mode, 1- phase. The SFB technology (Selective Fuse Breaking Technology)
More informationUser manual clima DL-110
User manual Moers, 18/11/14 Page 1 / 223 Content 1. Introduction...4 1.1. 1.2. 2. Product description...5 2.1. 2.2. 3. Safety information... 6 Order information...6 System devices...8 3.1. 3.2. 3.3. 3.4.
More informationOutput Signal Active Note DC V. Electrical Data Power Supply DC V, ±10%, 1.4 W
Differential Pressure Sensor (Air) Differential pressure transmitter with 8 selectable ranges 0 to 5/10 V, 4 to 20 ma outputs and Modbus functionality. NEMA 4X / IP65 rated enclosure. For monitoring the
More informationTechnical data sheets
echnical data sheets Ready-to-connect spring return actuator with emergency function for VAV and CAV units in ventilation and air conditioning systems in buildings For air dampers up to approx. 4 m 2 orque
More informationProduct and functional description
Product and functional description The RS 520/23 shutter / blind actuator is a KNX device with one relay output. The device is installed in an AP 118 Control Module Box or an AP 641 Room Control Box. The
More informationQUINT-DC-UPS/24DC/10. Extract from the online catalog. Order No.:
Extract from the online catalog QUINT-DC-UPS/24DC/10 Order No.: 2866226 Uninterruptible power supply 24 V DC/10 A, with integrated 1.3 Ah battery module. In the download area, there is a clearly arranged
More informationQUINT-DC-UPS/24DC/10. Extract from the online catalog. Order No.:
Extract from the online catalog QUINT-DC-UPS/24DC/10 Order No.: 2866226 Uninterruptible power supply 24 V DC/10 A, with integrated 1.3 Ah battery module. In the download area, there is a clearly arranged
More informationQUINT-DC-UPS/24DC/40. Extract from the online catalog. Order No.:
Extract from the online catalog QUINT-DC-UPS/24DC/40 Order No.: 2866242 Uninterruptible power supply 24 V/40 A. In the download area, there is a clearly arranged selection table available with load currents
More informationMINI-DC-UPS/12DC/4. Extract from the online catalog. Order No.:
Extract from the online catalog MINI-DC-UPS/12DC/4 Order No.: 2866598 Uninterruptible power supply with integrated power supply unit, 4 A, in combination with MINI-BAT/12/DC 1.6 Ah or 2.6 Ah Commercial
More informationProduct and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)
Product and functional description also functions if the bus cable is not connected or if the bus communication fails. After a long push button action (> 2 s), the other valve group is selected. The yellow
More informationQUINT-PS AC/24DC/10
Extract from the online catalog QUINT-PS-100-240AC/24DC/10 Order No.: 2938604 DIN rail power supply unit 24 V DC/10 A, primary switched-mode, 1- phase Commercial data EAN 4017918890537 Pack 1 Pcs. Customs
More informationQUICK START GUIDE. vau4/3. Frequency converter. operating instructions /12
operating instructions QUICK START GUIDE Frequency converter vau4/3 28100241101 12/12 1 Safety information Warning of electrical shock! Danger to life! Electrical shock can cause serious injury or even
More informationProduct and functional description
Product and functional description The UP 525/13 Universal Dimmer is a KNX device with one dimmer output. The device is installed in a flushmount wall box (60 mm Ø, depth 60 mm) or an installation box.
More information6173 AG GJB A0138
0073-1-6048 24661 ABB ibus EIB Combi actuator 6173 AG-101-500 GJB 000 6151 A0138 with 4-gang binary input for use as: 4-gang switching actuator 2x2-gang shutter actuator 2-gang switching-/1x2-fach-shutter
More informationDemonstration Case BENNING DB 1
Operating manual Demonstration Case BENNING DB 1 part no. 044132 Table of contents 1 Introduction...3 2 Safety instructions...4 3 Applicable regulations...5 4 Device description...5 4.1 Measuring / testing...
More informationAssembly and operating instructions DULCOMARIN II, N-Module (Power Supply Module without Relay) DXMaN
Assembly and operating instructions DULCOMARIN II, N-Module (Power Supply Module without Relay) DXMaN Please enter the identity code of your device here! DXMa _ Please carefully read these operating instructions
More information584 5WG AB_1 DELTA
Product DELTA profil DELTA style DELTA ambiente Display and control unit 5WG1 585-2AB01 pearl grey 5WG1 585-2AB11 titanium white 5WG1 585-2AB21 anthracite 5WG1 585-2AB71 silver 5WG1 585-2AB11 titanium
More informationAssembly and operating instructions DULCOMARIN II, P-Module (Power Supply Module with Relay) DXMaP
Assembly and operating instructions DULCOMARIN II, P-Module (Power Supply Module with Relay) DXMaP A0479 Please enter the identity code of your device here! DXMa _ Please carefully read these operating
More informationTROXNETCOM AS-i. Modules. Communication interface between a component and the controller. 06/2015 DE/en K
.2 X X testregistrierung TROXNETCOM AS-i Communication interface between a component and the controller The module is used to connect the control system with the components Integral AS-Interface slave
More informationQUINT-PS/1AC/24DC/10. Extract from the online catalog. Order No.:
Extract from the online catalog QUINT-PS/1AC/24DC/10 Order No.: 2866763 DIN rail power supply unit 24 V DC/10 A, primary-switched mode, 1- phase. The SFB technology (Selective Fusebreaking Technology)
More informationPush Button Interface UP 220D31
Product and Applications Description Application programs UP 220/31 07 B0 S4 On-off-toggle/Dim/Shu/Value 982203 The push button interface is a binary input and output devices for installation in in-wall
More informationDESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications
3 834 DESIO RX Individual room controllers for fan-coil systems, chilled ceilings and radiators, with MARK-compatible bus communications RXC20.1 RXC21.1 The RXC20.1 and RXC21.1 controllers are used for
More informationQUINT-PS/ 1AC/24DC/20/CO
Extract from the online catalog QUINT-PS/ 1AC/24DC/20/CO Order No.: 2320898 DIN rail power supply unit 24 V DC/20 A/CO, dip-coated circuit board, primary-switched, 1-phase. For the first time, SFB (selective
More informationPush button UP 287, 4 - fold
Product DELTA profil DELTA style Push button 1-fold pearl grey 5WG1 241-2AB01 titanium white 5WG1 285-2AB11 titanium white 5WG1 241-2AB11 basalt black 5WG1 285-2AB21 anthracite 5WG1 241-2AB21 titanium
More informationProduct and Applications Description. Application programs. instabus EIB Technical Product Information. February 2012
Product and Applications Description Application programs UP 220/31 07 B0 S4 On-off-toggle/Dim/Shu/Value 982201 The push button interface UP 220/31 is a binary input and output devices for installation
More informationRotary version, three-position control
4 622 Residential Air damper actuators GXD..31.1 Rotary version, three-position control Electric motor-driven actuators for three-position control 1.5 Nm nominal torque AC 24 V or AC 230 V rated voltage
More informationTRIO-PS/1AC/24DC/20. Extract from the online catalog. Order No.:
Extract from the online catalog TRIO-PS/1AC/24DC/20 Order No.: 2866381 DIN rail power supply unit, primary-switched mode, 1-phase, output: 24 V DC / 20 A Commercial data EAN 4046356046664 Pack 1 pcs. Customs
More informationProduct and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING
Product and Applications Description Note If the application program is not loaded completely by the ETS, you had better interrupt the 24 V voltage supply of the I/O-module during the loading interval.
More informationDevice technology. Supply Bus voltage V DC. Current consumption via bus. Accuracy in the range 300 1,000 ppm 1,000 2,000 ppm 2,000 5,000 ppm
2 2.1 Air Quality Sensor LGS/A 1.1 The ABB i-bus KNX Air Quality Sensor 1.1 is a combined sensor for CO 2, temperature and humidity measurement (relative humidity). Three independent thresholds can be
More informationProduct and functional description
Product and functional description The RS 525/23 Universal Dimmer is a KNX device with one dimmer output. The device is installed in an AP 118 Control Module Box or an AP 641 Room Control Box. The bus
More informationProducts no longer available
echnical data sheet NVF4-MF(-E)-R Modulating linear actuator with emergency function for -way and 3-way globe valves Actuating force 800 N Nominal voltage AC/DC 4 V Modulating control DC 0... 10 V Position
More informationQUINT-PS/24DC/48DC/ 5
Extract from the online catalog QUINT-PS/24DC/48DC/ 5 Order No.: 2320128 QUINT DC/DC converter, primary-switched, input: 24 V DC, output: 48 V DC/5 A Commercial data GTIN (EAN) sales group Pack Catalog
More informationArticle No. 6GK59230PS003AA2 6GK59240PS001AA2 Product Name. Power Supply SCALANCE PS924 PoE Input: 120/230V AC; Output: 54V/ 1.
Product Name Type of power supply Electrical data Input Waveform of the input Supply Power Supply SCALANCE PS924 PoE Input: 120/230V AC; Output: 54V/ 1.6A DC; NEC Class 2 single-phase AC Power Supply SCALANCE
More informationElectrical data Nominal voltage AC/DC 24 V Nominal voltage frequency. Draft
echnical data sheet LH24A-MF2-P Parmeterisable linear actuator for adjusting dampers and slide valves in technical building installations Air damper size up to approx. m² Actuating force 5 N Nominal voltage
More informationSITOP in the SIMATIC Design
Siemens AG 2017 /2 Introduction /3 1-phase, 24 V DC (for S7-300 and ET 200M) /9 1-phase, 24 V DC (for S7-1200) /11 1-phase, 24 V DC (for S7-1500 and ET 200MP) /14 3-phase, 24 V DC (ET 200pro) Siemens KT
More informationElectrical data Nominal voltage AC/DC 24 V Nominal voltage frequency
echnical data sheet NVK4A-SR-PC Modulating globe valve actuator for -way and 3-way globe valves Actuating force 000 N Nominal voltage AC/DC 4 V Control: modulating DC (0) V...0 V Nominal stroke 0 mm Design
More informationAS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input
Safety + standard I/O in one module Safety relay output with galvanically isolated contact sets, approved up to 230 V IEC 61508 SIL 3, EN ISO 13849-1/PLe Kat 4, EN 62061 SIL 3 Protection category IP20
More informationArticle no. BWU2045: AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input 1.23 NC
Safety + standard I/O in one module AS-i Safety relay output with galvanically isolated contact sets, approved up to 230 V IEC 61508 SIL 3, EN ISO 13849-1/PLe Kat 4, EN 62061 SIL 3 Protection category
More informationSTEP-PS/1AC/24DC/2.5. Extract from the online catalog. Order No.: DIN rail power supply of 24 V DC/2.5 A, primary switched, single phase.
Extract from the online catalog STEP-PS/1AC/24DC/2.5 Order No.: 2868651 DIN rail power supply of 24 V DC/2.5 A, primary switched, single phase. Commercial data EAN 4046356163224 Pack 1 pcs. Customs tariff
More informationManual Release 09/2002. cm-lon FOR LOGO! Communication with LOGO! with LON systems
Manual Release 09/2002 cm-lon FOR LOGO! Communication with LOGO! with LON systems s LOGO! Expansion Module Manual Chapters Safety Notices 1 Getting to know 2 Mounting and wiring the 3 Putting the into
More informationASI QUINT /2.4 EFD
Extract from the online catalog ASI QUINT 100-240/2.4 EFD Order No.: 2736686 Power supply unit für AS interface, 2.4 A, integrated ground fault detector, IP20 degree of protection Commercial data EAN 4017918959678
More informationTechnical data sheet. Technical data
echnical data sheet LMQ4A Damper actuator for adjusting air control dampers in ventilation and air-conditioning systems for building services installations For air dampers up to approx 8 m orque 4 Nm Nominal
More informationSBB4I2O230 ENG. Fire damper I/O Module. Benefits. Description
Fire damper I/O Module Benefits Ready-to-use junction box housing for fast and easy decentral installation One I/O-module can control and monitor two fire dampers Fast and easy wiring to the main controller
More informationOutput signal active note. Output signal. temperature DC V, DC V DC V, DC V DC V
Duct Air Quality Sensor Duct air quality sensor for detection of CO₂ with 0 to10 V output. Optional integrated, humidity, VOC sensors and LCD display. Type Overview Type active CO₂ 22DC-11 22DC-110L 22DCK-11
More informationZN230-24MP-1 MP-BUS
Actuators for heating, ventilation, air conditioning.. 4.. 6. ZN0-4- Product Information -Bus Power Unit # s-009-e- -BUS ZN0-4 ZN0-4 ZN0-4 Subject to technical changes 04090 / / -Bus Power Unit ZN0-4 Contents
More informationRotary actuators for ball valves
s 4 655 Rotary actuators for ball valves for ball valves VA..60.. / VB..60.., AC 24 V / DC 24 V / AC 230 V GSD..41.9A Electromotoric rotary actuators without spring return For On-Off control (2 wire SPDT)
More informationIF-80x Outdoor Terminal
95-10330_IF-800 V2016-10-20 Outdoor Terminal IF-80x Outdoor Terminal 1 IF-800 Outdoor / IF-801 We are pleased that you have decided to use a terminal of the IF-80x series for recording access data. Scope
More informationPHOENIX CONTACT - 07/2006
Buffer module with maintenance-free capacitor-based power storage device INTERFACE Data sheet 102035_03_en PHOENIX CONTACT - 07/2006 Description Short-term mains interruptions are bridged by QUINT BUFFER,
More informationPower Supply HARTING pcon
HARTING pcon 2120 Advantages Compact design and high power density Easy installation and tool-less connection Wide input range for world-wide use Wide operating temperature range (up to 70 C without derating)
More informationAC5160 SiPass integrated controller kit
AC5160 SiPass integrated controller kit SiPass integrated Wall housing with pre-assembled basic SiPass integrated components Equipped with one ACC (AC5100), two dual reader interfaces (ADD5100) and one
More informationTXM1.8T. Triac module Used for Thermic and motor-driven actuators (AC 24 V) TX-I/O
s 8 179 8179p01 TX-I/O Triac module sed for Thermic and motor-driven actuators (AC 24 V) AC 24 V-controlled devices TXM1.8T 8 triac outputs (AC 24 V), configured individually for: Permanent contact Three-point
More informationOperating instructions. Switching amplifier DN0210 DN / / 2015
Operating instructions Switching amplifier DN0210 DN0220 UK 80011079 / 00 01 / 2015 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5
More informationAssembly instruction / User manual
Assembly instruction / User manual 4-Q motor speed control unit digital, type DLR 24/xx-466 Technical data under reserve technical changes Please read these instruction before using and please keep safe
More informationPower supply. Interface technology in modular housing DIN rail devices, IM series. Features
Features 2,2 kò,5 W 5 V 5,1 V,3 W 24 VDC 2,5 A GN / L 85...264 VAC 9...375 VDC / N Safety extra-low voltage SELV IEC/ EN 695 Output voltage adjustable 24 28 VDC Nominal current 2.5 A Single/parallel operating
More informationETD-BL-1T-230(-PT) Multifunctional time relay with various functions and adjustable times. Data sheet. 1 Description
(-PT) Multifunctional time relay with various functions and adjustable times Data sheet 106395_en_02 PHOENIX CONTACT 20-06-08 1 Description Requirements pertaining to safety and system availability increase
More informationSwitching Actuators N530, 6AX Switching Actuators N532, 10AX Switching Actuators N534, 16/20AX
Gamma instabus Technical Product nformation Switching Actuators N53, 6AX Switching Actuators N532, 1AX Switching Actuators N534, 16/2AX 4x AC 23V 5WG1 53-1DB31 5WG1 532-1DB31 5WG1 534-1DB31 8x AC 23V 5WG1
More informationSafety control unit B1 / B1. for 2 to 16 machine safety sensors. Use. Types. + PLd according to EN ISO
Safety control unit for 2 to 16 machine safety sensors 470 121 B1 / 470 125 B1 + PLd according to EN ISO 13849-1 + two safety outputs and external contactor monitoring + for sensors with N.O./N.C. system
More informationPHOENIX CONTACT - 01/2010. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.
Uninterruptible power supply with integrated power supply unit INTERFACE Data sheet 104211_en_00 1 Description PHOENIX CONTACT - 01/2010 Features The MINI-DC-UPS provide an uninterruptible DC voltage both
More information9.5 nominal torque 4.5 W 16 VA. Min. 30 nominal voltage Min. 30 Nm. Reversible with switch By mounting. MIN (minimum position)
echnical data sheet EF24A- Communicative spring return actuator with emergency function for adjusting air dampers in ventilation and air conditioning systems in buildings For air dampers up to approx.
More informationIB IL 120 DI 1. Function. INTERBUS Inline Terminal With One Digital Input in the 120 V AC Voltage Area. Data Sheet 5764B
INTERBUS Inline Terminal With One Digital Input in the 120 V AC Voltage Area Data Sheet 5764B 09/2000 # % $ This data sheet is only valid in association with the INTERBUS Inline System Manual IB IL SYS
More informationTechnical data. Safety notes. Product features
Technical data sheet BKN230-MOD 11-00002.F Communication and power supply unit for motorised fire dampers Communication via RTU (RS-48) AC 230 V supply via Euro plug Power is supplied to the actuators
More informationDELTA profil wall switch, single UP 241/2 5WG AB_2
UP 241/2 5WG1 241-2AB_2 UP 241/3,with status LED 5WG1 241-2AB_3 UP 243/2 5WG1 243-2AB_2 UP 243/3,with status LED 5WG1 243-2AB_3 UP 245/2 5WG1 245-2AB_2 UP 245/3,with status LED 5WG1 245-2AB_3 UP 245/4,with
More informationExtract from the online catalog
Please note that the data given here has been taken from the online catalog. For comprehensive information and data, please refer to the user documentation at http://www.download.phoenixcontact.com. The
More informationPHOENIX CONTACT - 01/2007
Uninterruptible power supply INTERFACE Data Sheet 103123_00_en PHOENIX CONTACT - 01/2007 Description Especially compact and easy-to-use, the new MINI-DC-UPS/ 24 DC/2 is a combination of the power supply
More informationRXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station
s 3 836 3836P01 Desigo TRA PL-Link IO Block Use with PXC3 series room automation station RXM39.1 The PL-Link IO Block contains the inputs and outputs controlled by a room automation station via PL-Link.
More informationElo-1145-MSS-Zentraleinheit 471 M41 H31.book Page 1 Tuesday, September 6, :10 PM, Datum:
471 M41 H31 Betriebsanleitung MSS-Zentraleinheit Operating instructions MSS central control unit Notice d'utilisation Unité centrale MSS Istruzioni d'impiego Centralina MSS Datum: 06.09.2005 , Datum: 06.09.2005
More informationProduct and Applications Description. Application Programs. Example of Operation. Installation Instructions. load circuit AC 230/400V L1 L2 L3 N
Product and Applications Description Application Programs 20 A4 Binary 906401 4 binary outputs 1 status request available for each output 1 relation can be set allows 1 positive drive for each output initial
More informationPower consumption In operation At rest For wire sizing
echnical data sheet Modulating damper actuator for adjusting air control dampers in ventilation and airconditioning systems for building services installations For air dampers up to approx 08 m orque Nm
More informationRhino Redundancy Module PSM24-REM360S. Operating Instructions
Rhino Redundancy Module PSM4-REM360S Operating Instructions RHINO REDUNDANCY MODULE PSM4-REM360S Description With this module and two power supplies of the PSM series (78, 90, 56, 80 and 360 watt models),
More informationPower Supply HARTING pcon
HARTING pcon 2060 Advantages Compact design and high power density Easy installation and tool-less connection Wide input range for world-wide use Wide operating temperature range (up to 70 C without derating)
More informationBMF400 Input/output module
BMF400 Input/output module Input/output module with six universal inputs/outputs and four floating relay outputs for function extensions of the BMR bus module controller. Issue date: December 6, 2006 Subject
More informationCOMPACT LED DRIVERS. PrimeLine DALI dimmable & Selectable Current (Dip Switch) PrimeLine DALI DIMMABLE & SELECTABLE CURRENT (DIP SWITCH)
COMPACT LED DRIVERS PrimeLine DALI DIMMABLE & SELECTABLE CURRENT (DIP SWITCH) 186762, 186763 Typical Applications Built-in in compact luminaires Shop lighting Downlights PrimeLine DALI dimmable & Selectable
More informationOutput Signal. Temperature 22DTH-56M BACnet DC V, DC V. Electrical Data Power Supply DC V, ±10%, 0.7 W
Duct Sensor Humidity / Temperature For measuring the relative or absolute humidity and temperature in duct applications. The measured values and absolute humidity, dewpoint and enthalpy are transmitted
More informationLM24A-MOD. Cable 1 m, 6 x 0.75 mm 2 RJ12 socket
echnical data sheet Damper actuator for Modbus for adjusting air dampers in ventilation and air conditioning systems in buildings orque 5 Nm Nominal voltage AC/DC 4V Communication via Modbus RU (RS-485)
More informationTXM1.8RB. TX-I/O Blinds module
s 8 178 8178p01 TX-I/O Blinds module TXM1.8RB 8 non-floating relay outputs for... 4 blinds motors with 2 end switches, or 2 blinds motors with 3 end switches, or 2 blinds motors with 2 end switches + 1
More informationOperating instructions. Standstill monitor A / / 2011
Operating instructions Standstill monitor A300 UK 1 2 3 4 5 6 7 8 7390337 / 01 02 / 2011 1 2 3 4 5 6 7 8 switchpoint min max pulse/min power Made in Germany ifm electronic gmbh D 45127 Essen func. I II
More informationREDUNDANCY MODULE TSP-REM360 AND TSP-REM600
REDUNDANCY MODULE TSP-REM360 AND TSP-REM600 Operating Instructions Seite 1 Dimensions drawings: TSP-REM360 Weight: 0.882lb Gewicht: 0.40kg Seite 2 Dimensions drawings: TSP-REM600 Bottom view Top view Side
More informationCOMPACT LED DRIVERS. EasyLine Simple Fix. EasyLine SIMPLE FIX , , , , ,
COMPACT LED DRIVERS EasyLine SIMPLE FIX 186591, 186592, 186593, 186594, 186595, 186669 Typical Applications Built-in in or independent version for Shop lighting Downlights EasyLine with fixed output current
More informationUser manual Technical parameters
User manual Technical parameters thyro System english Thyristor for reactive current compensation 2 KBR GmbH Subject to technical changes Contents Intended use... 4 Safety Notes... 6 Application range...
More informationProduct Details. Contents. Features and Mounting Options for SUNNY STRING-MONITOR SSM24-11
Technical Information Product Details Features and Mounting Options for SUNNY STRING-MONITOR SSM24-11 Contents The Sunny String Monitor SSM24 11 is specifically designed for monitoring large PV generators.
More informationSRQ24A. Technical data. Safety notes. Rotary actuator for ball valves Torque 16Nm Nominal voltage AC/DC 24V Control: Open-close Running time 9s
SRQ24A Rotary actuator for ball valves orque 16Nm Nominal voltage AC/DC 24V Control: Open-close Running time 9s echnical data Electrical data Nominal voltage AC 24V, 50/60Hz / DC 24V Nominal voltage range
More informationProduct and Application Description
Technical Product-Information Product and Application Description The IP Gateway KNX-BACnet N 143 is is a DIN rail mounted device connecting a KNX installation with a system using BACnet/IP communication.
More informationSafety Switching Devices SNO 4003K. Basic device for Emergency-Stop and Safety Gate Applications PI E
EN 60204-1 Stop category 0 EN 954-1 Safety category 4 Basic device to EN 60204-1 and EN 954-1 single E-stop monitoring. Manual or automatic start Application up to safety category 2 and stop category 0
More informationEXPANSION PERIPHERAL CVM-R10 C. (Code ) INSTRUCTION MANUAL ( M / 00 A ) (c) CIRCUTOR S.A.
EXPANSION PERIPHERAL CVM-R10 C (Code 7 70 217 ) INSTRUCTION MANUAL ( M 981 170 / 00 A ) (c) CIRCUTOR S.A. ------ CVM-R10 C Peripheral --------------- Pag. 1 CVM-R10C EXPANSION PERIPHERAL 1.- DESCRIPTION
More informationCC COMPACT DIP SWITCH
CC COMPACT DIP SWITCH COMFORTLINE DIP SWITCH C-R5 186841, 186842, 186843 Typical Applications Built-in in compact luminaires for Shop lighting Downlights Panels ComfortLine DIP switch C-R5 SELECTABLE OUTPUT
More informationOperating Instructions PRO-AB /6.15. Leakage Current Measuring Adapter
Operating Instructions PRO-AB Leakage Current Measuring Adapter 3-349-621-15 3/6.15 Table of Contents Page 1 Scope of delivery...2 2 Safety Precautions...2 3 General...3 4 Preparing for Measurement...4
More informationPHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.
Primary-switched power supply for building automation INTERFACE Data sheet 103505_en_02 1 Description PHOENIX CONTACT - 08/2009 Features STEP POWER power supply units for building automation The new STEP
More informationAV24-MFT AV24-MFT2 AV24-MFT2-C105. Power consumption In operation For wire sizing N 1700 N Control Control signal Y Operating range
echnical data sheet AV4-MF()(-C105) Multi-functional linear actuators for -way and 3-way globe valves Actuating force 500 N Nominal voltage AC/DC 4 V Control: modulating DC 0 10 V Position feedback DC
More informationNEUROLOGIC RESEARCH CORPORATION MODEL 2500
NEUROLOGIC RESEARCH CORPORATION MODEL 2500 NETWORK HUMISTAT Compact, self-contained dehumidifier controller. 0.5 degrees C accuracy typical. RH sensor is digitally calibrated for 2% accuracy. Open communication
More informationAir damper actuators
4 604 OpenAir Air damper actuators Rotary version, AC/DC 24 V and AC 230 V GQD...1 GQD 1 Electric motor-driven actuators for two-position and three-position control as well as DC 0 10 V control 2 Nm nominal
More information252F 5WG FB_1 DELTA
Product DELTA i-system DELTA profil Fan-Coil Unit Operator Panels Hotel titanium white 5WG1 237-2FB11 pearl grey 5WG1 252-2FB01 carbon metallic 5WG1 237-2FB21 titanium white 5WG1 252-2FB11 aluminum metallic
More information