1 Solutions Guide for Cisco UCS B and C Series Servers The Cisco Unified Computing System is a next-generation data center platform that unites compute, network, storage access, and virtualization into a cohesive system designed to reduce TCO and increase business agility. The system integrates a low-latency, lossless 10GE unified network fabric with enterprise-class, x86-architecture servers. The system is an integrated, scalable, multi-chassis platform in which all resources participate in a unified management domain. Blade server applications present unique challenges in terms of rack level power distribution (ack PDU), cable management and physical access space requirements for hot-swappable blade components. This application guide provides specific physical infrastructure recommendations - enclosures, rack PDUs, and cable management - for Cisco UCS B and C Series servers in 5 simple steps: 1. Determine Power Configuration 2. Calculate Power Draw 3. Select ack PDUs 4. Select Enclosure 5. Select Cable Management

2 Contents Enclosures and ack PDU (rpdu) Overview...3 Step 1: Determine Power Configuration.. 4 Step 2: Calculate Power Load. 5 Step 3: Determine Chassis, Server Quantities per ecommended rpdu... 5 Tables 3A,3B (rpdus for B Chassis) Tables 3C,3D (rpdus for C Servers). 7 Metered ack PDUs Switched ack PDUs Step 4: Select Enclosures...10 Step 5: Shock Packaging 15 2

3 Enclosures and ack Mount Power Distributions Units Advanced PDUs Integrates power management capabilities with other products including Symmetra PX UPS, row and room PDUs, Inow cooling, NetShelter SX enclosures, and StruxureWare for Data Centers management software suite. Features zero U, low profile design, optimized for high-density rack power solutions to minimize interference between the ack PDU and hot-swap blade components. Comprehensive device, phase, and breaker bank level metering for overload protection, capacity planning purposes, and energy efficiency initiatives ight Angle C19/C20 connectors minimize bend radius at the connection point and reduce interference in the rear of an enclosure Cisco EnergyWise Compatible Full Featured Enclosures NetShelter SX enclosures offer the most standard, outof-box features to ease installation and speed deployment. Single enclosure design is flexible enough to accommodate various networking and server applications. Sizes Available: 42U, 45U, & 48U heights, 600mm (24 ) & 750mm (30 ) widths, and 1070mm (42 ) & 1200mm (47.2 ) depths. Available in black, white (North America), grey (Europe) for environments in which lighting is optimized Shock packaging now available for all sizes of cabinets makes ack and stack Easy for Equipment Integrators and Converged Deployments. NetShelter SX with Shock Packaging now certified by Cisco for preracking and shipping Cisco UCS Schneider Electric is a global leader in data center infrastructure - cooling, UPS, power distribution, racks and management. 3

4 Step 1: Determine Power Configuration B Series: The UCS B Series chassis includes four, single phase, hot-swappable redundant power supplies with IEC C20 Inlet connections. Follow the diagram below for a fully redundant 2N power configuration. ack PDU Source B ack PDU Source A Connect to C19 Outlets on ack PDU C Series: The UCS C-Series servers are similar to traditional rack mount servers. The C-Series is available in 1U, 2U, and 4U form factors. The various configuration options account for a large range in possible power loads. C200 C210 ack PDU Source A C460 ack PDU Source B 4

5 Step 2: Calculate Power Load (Watts) Use Cisco s UCS Power Calculator* to determine the power draw (watts) for the exact configuration (e.g. processors, memory, drives ) of UCS B and/or C series servers. ( Step 3: Determine Chassis, Server Quantities per ecommended ack PDUs (Tables 3A, 3B, 3C and 3D) Tables are organized based on the power capacity ratings for ack PDUs, showing both single phase and three phase options. Tables show maximum number of B-Series chassis and C servers that can be supported from recommended rack PDU, based on wattage from Step 2. Tables show recommended Metered rack PDUs with a zero U form factor and IEC outlets. In order to allow for loss of one power source, each rack PDU has been sized and provisioned for approximate power rating of the chassis or server. Ensure recommended rack PDU input connector can be connected to an onsite circuit. Additional rack PDUs in different configurations are shown on page 10 and 11. 5

6 Table 3A : Number of B-Series Chassis / ecommended ack PDU (North America) Table 3B: Number of B-Series Chassis / ecommended ack PDU (International) Typical UCS configurations will include 2 Fabric Interconnects (FI) at the top of the rack. Calculations in the tables include 800W for the FIs If the Cisco Power Calculator indicates the FI s draw more than 800W, it is recommended double checking the rack PDU selection to confirm total wattage of connected devices does not exceed rack PDU rating. Ensure the selected rack PDU has two C13 receptacles to connect the FIs. * Limited by number of C19 outlets on rack PDU ** Limited by internal circuit breaker capacity. UL mandates 80% de-rating (16A) for continuous loads. 6

7 Table 3C: Number of C-Series Servers / ecommended ack PDU (North America) Table 3D: Number of C-Series Servers / ecommended ack PDU (International) Typical UCS configurations will include 2 Fabric Interconnects (FI) at the top of the rack. Calculations in the tables include 800W for the FIs If the Cisco Power Calculator indicates the FI s draw more than 800W, it is recommended double checking the rack PDU selection to confirm total wattage of connected devices does not exceed rack PDU rating. Ensure the selected rack PDU has two C13 receptacles to connect the FIs. * Limited by number of C13 outlets on rack PDU ** Limited by internal circuit breaker capacity. UL mandates 80% de-rating (16A) for continuous loads. 7

8 ack PDU Charts - Metered Metered ack Power Distribution Units (PDUs) provide active metering to enable energy optimization and circuit protection. User-defined alarm thresholds mitigate risk with real-time local and remote alerts to warn of potential circuit overloads. Metered ack PDUs provide power utilization data to allow Data Center managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership. AP8000 series Metered ack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and ultra low profile circuit breakers. Users can access and configure Metered ack PDUs through secure Web, SNMP, or Telnet Interfaces. Metered by Outlet ack PDUs Metered by Outlet ack Power Distribution Units (PDUs) provide all of the active metering features of Metered ack PDUs and include real-time remote monitoring of each individual outlet. 8 ack PDUs recommended on page 6 and 7.

9 ack PDU Charts - Switched Switched ack Power Distribution Units (PDUs) enable advanced, user-customizable power control and active monitoring. emote outlet level controls allow power on/off functionality for power recycling to remotely reboot equipment and restrict unauthorized use of individual outlets. Power sequencing time delays allow users to define the order in which to power up or down attached equipment. Avoid circuit overload during power recovery and extend uptime of critical equipment by prioritizing the load shedding. Input Current metering provides real-time remote monitoring of connected loads. AP8000 series Switched ack PDUs include real power monitoring, a temperature/humidity sensor port, and locking IEC receptacles. User-defined alarms warn of potential circuit overloads before critical IT failures occur. Users can access, configure, and control Switched ack PDUs through secure Web, SNMP, or Telnet Interfaces. Switched with Metering by Outlet Metered by Outlet with Switching ack Power Distribution Units (PDUs) enable advanced, user-customizable power control and individual outlet power metering. 9

10 10

11 Enclosure ecommendations UCS B-Series The following diagrams are intended to show how the UCS B-Series chassis fits within the different widths and depths of the NetShelter SX. Blade chassis in general offer unique challenges of space and access. The rear area needs to be completely clear of cable managers and PDUs in order to access the rear hot-swappable components. In addition, the B-Series chassis is about 75mm (3 in) deeper than most rack mount equipment, lessening the available rear space. 600mm/24 Wide Enclosures TOP VIEW Cisco UCS 5108 Chassis Cisco UCS 5108 Chassis 1200 mm Cisco UCS 5100 Chassis Yellow areas show data cabling area. ecommended cable managers : A7710 Chassis hot swap component access 600 mm Chassis hot swap component access Chassis hot swap component access 600 mm 600 mm The 1070mm (42 ) deep enclosure is not recommended due to lack of the space for cable management. If 1070mm deep must be used, maximize space by rotating PDUs 90 degrees (Use A7711) so the outlets are facing the rear. Add right angle power cord kits to improve clearance with enclosure frame. For cable management, use A7540 Toolless Cable ing kit in any available space. The 1200mm (47 ) deep enclosure offers more mounting options for PDUs and cable managers. The above two diagrams show suggested options. PDUs should be mounted in rear-most toolless channels to avoid interference with blade chassis components. If it is preferred to mount PDUs on opposite sides, maximize space by rotating PDUs 90 degrees so that the outlets are facing the rear. If the preferred PDU orientation is outlets-facing-in then consider mounting PDUs on the left side (as viewed above center). The rear power modules of the blade chassis are biased to the right offering more clearance on the left side. ecommended cable manager A7710 mounted in toolless rear channels. AP8866 rack PDU shown in illustration; however, configuration would be common for any PDU selection and number of UCS 5108 blade server chassis EA VIEW UCS 6100, 6200 Series Fabric Interconnects (can be positioned to customer preference) 11

12 Enclosure ecommendations B-Series (cont) The below diagrams show the available rear space for 750mm (30 ) wide NetShelter s and the recommended ack PDU and cable management options. 750mm/30 Wide Enclosures TOP VIEW ack PDUs can be placed on either side of rack enclosure Cisco UCS 5108 Chassis Chassis hot swap component access 750 mm Cisco UCS 5108 Chassis Chassis hot swap component access 750 mm Cisco UCS 5108 Chassis Chassis hot swap component access 750 mm Yellow areas show data cabling area. ecommended cable managers: A7710, A7721, or A7580A 1200mm enclosure has additional space for access and cable management (can use additional A7710, A7721, or A7580A kits) The wider 750mm (30 ) enclosures are the recommended enclosures for blade applications. They offer the most clearance with ack PDUs/cable managers and the removable modules of the blade chassis. If the preferred ack PDU orientation is outlets-facing-in then consider mounting ack PDUs on the left side (as viewed above center). The rear modules of the blade chassis are biased to the right offering more clearance on the left side. ecommended cable manager A7710 mounted in toolless rear channels. EA VIEW UCS 6100, Series Fabric Interconnects (can be positioned to customer preference) 12

13 Enclosure ecommendations UCS C-Series The following diagrams are intended to show how the UCS C-Series servers fit within the different widths and depths of the NetShelter SX. The rear area needs to be completely clear of cable managers and PDUs in order to access the rear server components. The C-Series servers range in depth from inches resulting in greater available rear space than the B-Series. 600mm/24 Wide Enclosures TOP VIEW Cisco C-Series Server 1200 mm Cisco C-Series Server 1200 mm Yellow areas show data cabling area. ecommended cable managers: A7710 Chassis ear Component Clearance 600 mm Chassis ear Component Clearance 600 mm The 1070mm (42 ) deep enclosure is not recommended due to lack of space for cable management. If 1070mm deep must be used, maximize space by rotating PDUs 90 degrees (Use A7711) so the outlets are facing the rear. Add right angle power cord kits to improve clearance with enclosure frame. For cable management, use A7540 Toolless Cable ing kit in any available space. The 1200mm (47 ) deep enclosure offers more mounting options for ack PDUs and cable managers. The above two diagrams show suggested options. ack PDUs should be mounted in rear-most toolless channels to avoid interference with server components. If it is preferred to mount ack PDUs on opposite sides, maximize space by rotating PDUs 90 degrees so that the outlets are facing the rear. If the preferred ack PDU orientation is outlets-facing-in then consider mounting ack PDUs on the left side (as viewed above center). The rear power modules input plugs of the server are biased to the right offering more clearance on the left side. ecommended cable manager A7710 mounted in toolless rear channels. AP8841 rack PDU shown in illustration; however, configuration would be common for any PDU selection and number of UCS C-Series server UCS 6100, 6200 Series Fabric Interconnects (can be positioned to customer preference) EA VIEW 13

14 Enclosure ecommendations UCS C-Series (cont) The below diagrams show the available rear space for 750mm (30 ) wide NetShelter s and the recommended ack PDU and cable management options. 750mm/30 Wide Enclosures TOP VIEW ack PDUs can be placed on either side of rack enclosure 1070 mm 1070 mm Cisco C-Series Server Chassis ear Component Clearance Yellow areas show data cabling area. ecommended cable managers: A7710, A7721, or A7580A 1200mm enclosure has additional space for access and cable management (can use additional A7710, A7721, or A7580A kits) 750 mm The wider 750mm (30 ) enclosures are the recommended sizes. They offer the best clearance with absolutely no interference with the PDUs/cable managers and the removable components of the server. ecommended cable manager A7710 mounted in toolless rear channels. AP8841 rack PDU shown in illustration; however, configuration would be common for any PDU selection and number of UCS C-Series server EA VIEW UCS 6100, 6200 Series Fabric Interconnects (can be positioned to customer preference) 14

15 Enclosures with Shock Packaging ack and stack made Easy for Equipment Integrators and Converged Deployments. Cabinet paired with shock absorbing pallet, unloading ramp, and impact resistant shell. NetShelter SX now Cisco certified for preracking and shipping Cisco UCS emove outer wrap layers ack stays on pallet during integration eapply protective packaging Ship to customer site for installation Height Width Depth Part Load rating inside cabinet 42 U 600mm (24in) 750mm (30in) 1070mm (42in) A3100SP 907kg (2000lb) 1200mm (48in) A3300SP 907kg (2000lb) 1070mm (42in) A3150SP 907kg (2000lb) 1200mm (48in) A3350SP 907kg (2000lb) 45U 48U 600mm (24in) 750mm (30in) 600mm (24in) 750mm (30in) 1070mm (42in) A3105SP 907kg (2000lb) 1200mm (48in) A3305SP 907kg (2000lb) 1070mm (42in) A3155SP 907kg (2000lb) 1200mm (48in) A3355SP 907kg (2000lb) 1070mm (42in) A3107SP 907kg (2000lb) 1200mm (48in) A3307SP 907kg (2000lb) 1070mm (42in) A3157SP 907kg (2000lb) 1200mm (48in) A3357SP 907kg (2000lb) Cabinets designed to safely load, transport, unload and deploy a cabinet with up to 2000lb (900kg) of IT equipment installed Schneider Electric. All rights reserved. Other trademarks are property of their respective owners. Specifications are subject to change without notice.

Metered Rack PDU Rack PDU, Metered, Zero U, 10A, 230V, (16) C13

Metered Rack PDU Rack PDU, Metered, Zero U, 10A, 230V, (16) C13 Metered Rack PDU Rack PDU, Metered, Zero U, 10A, 230V, (16) C13 APC Metered Rack PDU, Input: 230V, Input Connections: IEC-320 C14, Cord Length: 10 feet ( 3.05 meters ), Output: 230V, Output Connections:

More information

Symmetra PX 48kW. Scalable from 16 to 48kW. Make the most of your energy TM. Modular, Scalable, High-Efficiency Power Protection for Data Centers

Symmetra PX 48kW. Scalable from 16 to 48kW. Make the most of your energy TM. Modular, Scalable, High-Efficiency Power Protection for Data Centers Symmetra PX 48kW Scalable from 16 to 48kW Modular, Scalable, High-Efficiency Power Protection for Data Centers High performance, right-sized, modular, scalable, 3-phase power protection with high efficiency

More information

Rack Selection Guide for NetShelter SX

Rack Selection Guide for NetShelter SX Rack Selection Guide for NetShelter SX Choosing the right rack based on application and equipment type Click here to download the new White Paper #201: How to Choose an IT Rack Rack Selection Guide for

More information

Rack Power Distribution. Rack power distribution offerings for entry-level networking equipment and high-density server and blade environments

Rack Power Distribution. Rack power distribution offerings for entry-level networking equipment and high-density server and blade environments Rack Power Distribution Rack power distribution offerings for entry-level networking equipment and high-density server and blade environments Wiring Closet/Server Rooms IP Telephony High Density Small/Medium

More information

Tripp Lite PDUs POWER DISTRIBUTION UNITS. Reliable rack power distribution for high-density IT environments. Introduction 2-3.

Tripp Lite PDUs POWER DISTRIBUTION UNITS. Reliable rack power distribution for high-density IT environments. Introduction 2-3. POWER DISTRIBUTION UNITS Tripp Lite rack power distribution for high-density IT environments. Introduction 2-3 Basic 4 Metered 5 Monitored 6 Switched 7 ATS 8 Hot-Swap 8 INTRODUCTION Tripp Lite Rack increase

More information

CS-12HDE444C8 (Master) Key Features. CL-12HDE444C8 (Link)

CS-12HDE444C8 (Master) Key Features. CL-12HDE444C8 (Link) CS-12HDE444C8 (Master) CL-12HDE444C8 (Link) The Server Technology Smart PDU provides local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a per-phase basis while

More information

CS-24VD-L30MA (Master) Key Features. CL-24VD-L30MA (Link)

CS-24VD-L30MA (Master) Key Features. CL-24VD-L30MA (Link) CS-24VD-L30MA (Master) CL-24VD-L30MA (Link) The Server Technology Smart PDU provides local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a per-phase basis while

More information

QuickSpecs. HPE Metered and Switched Power Distribution Units (PDU) Overview

QuickSpecs. HPE Metered and Switched Power Distribution Units (PDU) Overview HPE Metered and Switched Power Distribution Units (PDU) Overview Looking for a power distribution unit that meets the demands of high temperature operating environments and provides monitoring and switching

More information

Configurable power distribution

Configurable power distribution Configurable power distribution 60 150 kva The easy-to-deploy for data centers with custom requirements Configured to order, factoryassembled power distribution for IT equipment in any size data center

More information

CS-10H0A413H3 (Master) Key Features. CL-10H0A413H3 (Link)

CS-10H0A413H3 (Master) Key Features. CL-10H0A413H3 (Link) CS-10H0A413H3 (Master) CL-10H0A413H3 (Link) The Server Technology Smart PDU provides local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a per-phase basis while

More information

Summit Virtual Chassis Design and Installation Guide

Summit Virtual Chassis Design and Installation Guide Summit Virtual Chassis Design and Installation Guide Extreme Networks, Inc. 10460 Bandley Drive Cupertino, California 95014 (888) 257-3000 http://www.extremenetworks.com Published: June 1998 Part No: 120031-00

More information

Modular, scalable, high-efficiency power protection for data centers

Modular, scalable, high-efficiency power protection for data centers Scalable to 20 kw Modular, scalable, high-efficiency power protection for data centers The Symmetra TM PX 20 kw is a world-class, high-efficiency, ENERGY STAR qualified power protection system designed

More information

C2W36CE-DQME2M99 (Master) C2X36CE-DQME2M99 (Expansion) Key Features

C2W36CE-DQME2M99 (Master) C2X36CE-DQME2M99 (Expansion) Key Features C2W36CE-DQME2M99 (Master) C2X36CE-DQME2M99 (Expansion) The Server Technology PRO2 Switched PDU provides control of outlet power and local LED input current monitoring, allowing IT personnel to determine

More information

Power Control and Distribution

Power Control and Distribution Power Control and Distribution MasterSwitch Series Remote power distribution units for network administrators, Co-Location facilities, ISPs, and applications where remote control of outlets is required

More information

IBM 1U Switched and Monitored Power Distribution Units IBM System x at-a-glance guide

IBM 1U Switched and Monitored Power Distribution Units IBM System x at-a-glance guide IBM 1U Switched and Monitored Power Distribution Units IBM System x at-a-glance guide The IBM 1U Switched and Monitored Power Distribution Units (PDUs) make it quick and simple to deploy, protect, and

More information

Power Distribution. For technical support call Online catalog available at leviton.com 461

Power Distribution. For technical support call Online catalog available at leviton.com 461 INDEX FLX Series... 463 Switched Series... 464 Metered Series... 465 P1000 Series... 466 5500 & 5505 Series... 467 4500 Series... 468 For technical support call 800-824-3005 Online catalog available at

More information

G5 PDU Installation Guide

G5 PDU Installation Guide G5 PDU Installation Guide 1 Contents Before You Begin... 3 Overview... 3 Important Safety Information... 3 Required Tools... 5 Section 1 Introduction... 6 Classification Overview... 6 Features... 7 Form

More information

IBM eserver System x and BladeCenter IBM DPI PDU+ Power Distribution Units. 10/9/ IBM Corporation

IBM eserver System x and BladeCenter IBM DPI PDU+ Power Distribution Units. 10/9/ IBM Corporation IBM eserver System x and BladeCenter IBM DPI PDU+ Power Distribution Units 10/9/2007 Agenda System x Options Program and PDU market overview What is a PDU? Why do you need an IBM DPI PDU? IBM DPI PDU offering

More information

HP Rackmountable 3 Phase Uninterruptible Power Systems Overview

HP Rackmountable 3 Phase Uninterruptible Power Systems Overview Overview Crowded data centers and racks filled to capacity with storage devices, monitors, servers communications devices, and other equipment are driving the need for uninterruptible power with increased

More information

Product brochure. Eaton epdu G3. Simplify installation. Enhance operation. Maximize control.

Product brochure. Eaton epdu G3. Simplify installation. Enhance operation. Maximize control. Product brochure Eaton epdu G3 Simplify installation. Enhance operation. Maximize control. Power distribution made better by Eaton The Eaton epdu G3 rack mounted power distribution units (PDUs) provide

More information

Models. Specifications

Models. Specifications CAN YOUR PDU PIVOT? TRUE INNOVATION. ONLY FROM SERVER TECH. You ve never seen anything like this before. Intro- TM ducing the PDU Power Pivot, the newest patented innovation from Server Tech, inventors

More information

APC APPLICATION NOTE #146

APC APPLICATION NOTE #146 #146 Hot Aisle Containment Application Guidelines and Approved Configurations By Kevin Lemke Abstract The Hot Aisle Containment System (HACS) is a modular ceiling panel and door system for use in isolating

More information

Retired. Full Rack Vertical PDU Model (Ideal for 36U to 47U racks)

Retired. Full Rack Vertical PDU Model (Ideal for 36U to 47U racks) Overview The HP Monitored PDUs allow administrators and facility personnel to monitor current draw directly at the rack and per PDU. HP Monitored PDUs are available in both 1 phase and 3 phase and in single

More information

ECO PDU Power Distribution Unit

ECO PDU Power Distribution Unit ECO PDU Distribution Unit PE6108/PE6208/PE8108/PE8208 ATEN has developed a new generation of green energy power distribution units (PDUs) to effectively increase the efficiency of data center power usage.

More information

PE8216/PE8324. Energy Intelligence Solutions

PE8216/PE8324. Energy Intelligence Solutions PE8216/PE8324 As part of its NRGence line, ATEN has developed a new generation of green energy power distribution units (eco PDUs) to effectively increase the efficiency of data center power usage. The

More information

Prisma II Platform. Optoelectronics

Prisma II Platform. Optoelectronics Optoelectronics Prisma II Platform Description In optical transmission systems, the network platform forms the foundation of the product family. The Prisma II platform provides network operators with the

More information

QuickSpecs. HP Intelligent Power Distribution Unit (ipdu) Overview

QuickSpecs. HP Intelligent Power Distribution Unit (ipdu) Overview Overview You cannot control what you cannot monitor. The new brings state of the art management and control to rack mounted power distribution units (PDU) to prevent over provisioning of power from restricting

More information

Cisco CRS 16-Slot Chassis Power Systems

Cisco CRS 16-Slot Chassis Power Systems This chapter includes the following sections: Power specifications are provided in Technical Specifications Power Systems Overview, on page 1 Power Component Information Common to the Two Types of Power

More information

Symmetra LX APC Symmetra LX 8kVA Scalable to 16kVA N+1 Rack-mount, 208/240V Input, 208/240V and 120V Output

Symmetra LX APC Symmetra LX 8kVA Scalable to 16kVA N+1 Rack-mount, 208/240V Input, 208/240V and 120V Output Symmetra LX APC Symmetra LX 8kVA Scalable to 16kVA N+1 Rack-mount, 208/240V Input, 208/240V and 120V Output APC Symmetra LX, 6400 Watts / 8000 VA,Input 208V / Output 120V, 208V, Interface Port DB-9 RS-232,

More information

Installation Job Aid for Ethernet Routing Switch 5900 Series

Installation Job Aid for Ethernet Routing Switch 5900 Series Installation Job Aid for Ethernet Routing Switch 5900 Series Notices NN47211-301 Issue 05.01 November 2017 Notice paragraphs alert you about issues that require your attention. The following paragraphs

More information

ECO PDU. Features. PE5220sA

ECO PDU. Features. PE5220sA ECO PDU PE5220s As part of its NRGence line, ATEN has developed a new generation of green energy power distribution units (PDUs) to effectively increase the efficiency of data center power usage. The NRGence

More information

HPE BladeSystem c3000 Enclosure Quick Setup Instructions

HPE BladeSystem c3000 Enclosure Quick Setup Instructions HPE BladeSystem c3000 Enclosure Quick Setup Instructions Part Number: 446990-007 2 Site requirements Select an installation site that meets the detailed installation site requirements described in the

More information

ftserver 3300 Service Bulletin

ftserver 3300 Service Bulletin ftserver 3300 Service Bulletin Last Updated 2/12/04 1. Overview The ftserver 3300 is based on the 2.4-GHz or 3.06-GHz Intel IA32 architecture using Intel s Xeon processors and one-way or two-way (one or

More information

ECO PDU PE7108/PE7208

ECO PDU PE7108/PE7208 PE7108/PE7208 ATEN has developed a new generation of green energy power distribution units (PDUs) to effectively increase the efficiency of data center power usage. The PE7108 / PE7208 eco PDUs are intelligent

More information

A Scalable, Reconfigurable, and Efficient High Density Data Center Power Distribution Architecture

A Scalable, Reconfigurable, and Efficient High Density Data Center Power Distribution Architecture A Scalable, Reconfigurable, and Efficient High Density Data Center Power Distribution White Paper 129 Revision 2 by Neil Rasmussen > Executive summary Significant improvements in efficiency, power density,

More information

THE OFFICIAL TRADE JOURNAL OF BICSI

THE OFFICIAL TRADE JOURNAL OF BICSI ICT TODAY THE OFFICIAL TRADE JOURNAL OF BICSI January/February 2017 Volume 38, Number 1 + PLUS + Information Security and ESS in the Age of the Internet of Things + Grounding System Design and Testing

More information

5 GREAT REASONS to Use Colored Rack PDUs

5 GREAT REASONS to Use Colored Rack PDUs 5 GREAT REASONS to Use Colored Rack PDUs TABLE OF CONTENTS WHY COLOR RACK PDUS? 5 Great Reasons to Use Colored Rack PDUs REASON 1. Easily Identify Redundant Power Feeds to IT Equipment REASON 2. Make it

More information

ECO PDU PE5108/PE5208

ECO PDU PE5108/PE5208 1 NRGence Energy Intelligence Solutions PE5108/PE5208 ATEN has developed a new generation of green energy power distribution units (PDUs) to effectively increase the efficiency of data center power usage.

More information

Energy Management Solutions

Energy Management Solutions Energy Management Solutions Metered ipdu (EN1000 Series): Networked, realintroducing the world s most innovative intelligent Power Distribution time input and circuit breaker level monitoring for early

More information

Product Brochure. Eaton epdu G3 Managed

Product Brochure. Eaton epdu G3 Managed Product Brochure Eaton epdu G3 Managed Advanced power management and precision control The Eaton epdu third generation (G3) Managed models build on Eaton s existing state-of-the-art epdu G3 technology

More information

Internet Office 120V 550VA 300W Standby UPS, Ultra-Compact Desktop, USB

Internet Office 120V 550VA 300W Standby UPS, Ultra-Compact Desktop, USB Internet Office 120V 550VA 300W Standby UPS, Ultra-Compact Desktop, USB MODEL NUMBER: INTERNET550U Highlights 550VA ultra-compact 120V standby UPS Maintains AC output during power failures 4 UPS battery

More information

Sentry Metered, Smart, and Switched High Density 30 Receptacle 208VAC, 3-Phase 30A Products

Sentry Metered, Smart, and Switched High Density 30 Receptacle 208VAC, 3-Phase 30A Products Sentry Metered,, and High Density 30 Receptacle 208VAC, 3-Phase 30A Products The shift to 3-Phase power in North American data centers has driven demand for PDUs with increased flexibility. Mixed C13 /

More information

SmartPro LCD 120V 1200VA 700W Line- Interactive UPS, AVR, 2U Rack/Tower, LCD, USB, DB9 Serial, 8 Outlets

SmartPro LCD 120V 1200VA 700W Line- Interactive UPS, AVR, 2U Rack/Tower, LCD, USB, DB9 Serial, 8 Outlets SmartPro LCD 120V 1200VA 700W Line- Interactive UPS, AVR, 2U Rack/Tower, LCD, USB, DB9 Serial, 8 Outlets MODEL NUMBER: SMART1200LCD Highlights Supports a half-load (350W) up to 14.3 min. during power outage

More information

IFS MCR-R15 Media Converter Rack User Manual

IFS MCR-R15 Media Converter Rack User Manual IFS MCR-R15 Media Converter Rack User Manual P/N 1076518 REV A ISS 08FEB12 Copyright Trademarks and patents Manufacturer Version Certification FCC compliance ACMA compliance European Union directives 2012

More information

Power Distribution Units for Data Centers

Power Distribution Units for Data Centers BRC_PowerMax_INT_Draft_I.qxp_Layout 1 9/11/17 2:00 PM Page 2 Power Distribution Units for Data Centers WWW.SIEMON.COM PowerMax Power Distribution Units 2 Siemon s PowerMax line of PDUs range from basic

More information

Symmetra LX APC Symmetra LX 8kVA Scalable to 8kVA N+1 Rack-mount, 208/240V Input, 208/240V and 120V Output

Symmetra LX APC Symmetra LX 8kVA Scalable to 8kVA N+1 Rack-mount, 208/240V Input, 208/240V and 120V Output Symmetra LX APC Symmetra LX 8kVA Scalable to 8kVA N+1 Rack-mount, 208/240V Input, 208/240V and 120V Output APC Symmetra LX, 6400 Watts / 8000 VA,Input 208V / Output 120V, 208V, Interface Port DB-9 RS-232,

More information

PDU. InfraPower POWER AUSTI AUSTIN AUSTIN AUSTIN 3 PHASE WSI WI WS W MD BASIC. Enclosure Power Management Solutions

PDU. InfraPower POWER AUSTI AUSTIN AUSTIN AUSTIN 3 PHASE WSI WI WS W MD BASIC. Enclosure Power Management Solutions PDU A AUSTI POWER 3 PHASE WSI WI WS W MD BASIC Temperature & Humidity Sensors A pair of sensors can be connected to one single W series PDU meter. 3 PHASE Free Management Software Manager enhances the

More information

Lenovo 42U 1200mm Deep Racks Product Guide

Lenovo 42U 1200mm Deep Racks Product Guide Lenovo 42U 1200mm Deep Racks Product Guide Lenovo 42U 1200 mm Deep Static and Dynamic Rack offerings are industry-standard 19-inch server cabinets that are designed for high availability server environments.

More information

Power Distribution Units for Data Centers

Power Distribution Units for Data Centers WWW.SIEMON.COM Power Distribution Units for Data Centers PowerMax Power Distribution Units Siemon s PowerMax line of PDUs range from basic and metered for simple, reliable and cost-effective power distribution,

More information

Emerson Network Power Rack PDU Solutions Rack Power Distribution For Critical IT Equipment. AC Power For Business-Critical Continuity

Emerson Network Power Rack PDU Solutions Rack Power Distribution For Critical IT Equipment. AC Power For Business-Critical Continuity Emerson Network Power Rack PDU Solutions Rack Power Distribution For Critical IT Equipment AC Power For Business-Critical Continuity Enhanced Performance And Management Of Dynamic IT Spaces IT space is

More information

ISILON HD-SERIES. Isilon HD400 ARCHITECTURE SPECIFICATION SHEET Dell Inc. or its subsidiaries.

ISILON HD-SERIES. Isilon HD400 ARCHITECTURE SPECIFICATION SHEET Dell Inc. or its subsidiaries. SPECIFICATION SHEET ISILON HD-SERIES Isilon HD400 The rapid growth of unstructured data combined with increasingly stringent compliance requirements is resulting in a growing need for efficient data archiving

More information

DMC-1000 Chassis-Based Media Converter

DMC-1000 Chassis-Based Media Converter DMC-1000 Chassis-Based Media Converter User s Guide Rev. 01 (Jan. 2002) 6012-9600131 (1907MCR11616000) Printed In Taiwan RECYCLABLE i TABLE OF CONTENTS TABLE OF CONTENTS... II PREFACE... 3 19 MEDIA CONVERTER

More information

Internet Office 120V 750VA 450W Standby UPS, Ultra-Compact Desktop, USB

Internet Office 120V 750VA 450W Standby UPS, Ultra-Compact Desktop, USB Internet Office 120V 750VA 450W Standby UPS, Ultra-Compact Desktop, USB MODEL NUMBER: INTERNET750U Highlights 750VA ultra-compact 120V standby UPS Maintains AC output during power failures 6 UPS battery

More information

Model #: SMART3000RM2U

Model #: SMART3000RM2U Tripp Lite 1111 West 35th Street Chicago, IL 60609 USA Telephone: +(773) 869 1234 E-mail: saleshelp@tripplite.com Model #: SMART3000RM2U SmartPro Expandable Rack/Tower UPS System - Intelligent, line-interactive

More information

Modernize Your IT with FlexPod. NetApp & Schneider Electric

Modernize Your IT with FlexPod. NetApp & Schneider Electric Modernize Your IT with FlexPod NetApp & Schneider Electric Hyper-distribution of Applications and Data 30M New devices connected every week 277X Data created by IoE devices v. end-user 180B Mobile apps

More information

Symmetra LX APC Symmetra LX 8kVA Scalable to 16kVA N+1, Tower 208/240V Input, 208/240V and 120V Output

Symmetra LX APC Symmetra LX 8kVA Scalable to 16kVA N+1, Tower 208/240V Input, 208/240V and 120V Output Symmetra LX APC Symmetra LX 8kVA Scalable to 16kVA N+1, Tower 208/240V Input, 208/240V and 120V Output APC Symmetra LX, 6400 Watts / 8000 VA,Input 208V / Output 120V, 208V, Interface Port DB-9 RS-232,

More information

IBM BladeCenter HT ac and dc model chassis accommodates BladeCenter blade servers for telecommunications environments and new options

IBM BladeCenter HT ac and dc model chassis accommodates BladeCenter blade servers for telecommunications environments and new options IBM Europe Announcement ZG07-0187, dated February 13, 2007 IBM BladeCenter HT ac and dc model chassis accommodates BladeCenter blade servers for telecommunications environments and new options Key prerequisites...2

More information

Cisco TelePresence Conductor

Cisco TelePresence Conductor Data Sheet : Simple Natural Conferencing Product Overview Figure 1. Cisco TelePresence Conductor simplifies multiparty video communications, orchestrating the different resources needed for each conference

More information

SmartOnline 120V 1.5kVA 1.2kW Double- Conversion UPS, 2U Rack/Tower, Extended Run, Network Card Options, USB, DB9 Serial

SmartOnline 120V 1.5kVA 1.2kW Double- Conversion UPS, 2U Rack/Tower, Extended Run, Network Card Options, USB, DB9 Serial SmartOnline 120V 1.5kVA 1.2kW Double- Conversion UPS, 2U Rack/Tower, Extended Run, Network Card Options, USB, DB9 Serial MODEL NUMBER: SU1500RTXL2UA Highlights 1500VA / 1.5kVA / 1200 watt on-line double-conversion

More information

Cisco UCS C200 M2 High-Density Rack-Mount Server

Cisco UCS C200 M2 High-Density Rack-Mount Server Cisco UCS C200 M2 High-Density Rack-Mount Server Product Overview Cisco UCS C-Series Rack-Mount Servers extend unified computing innovations to an industry-standard form factor to help reduce total cost

More information

Veritas NetBackup on Cisco UCS S3260 Storage Server

Veritas NetBackup on Cisco UCS S3260 Storage Server Veritas NetBackup on Cisco UCS S3260 Storage Server This document provides an introduction to the process for deploying the Veritas NetBackup master server and media server on the Cisco UCS S3260 Storage

More information

Switched Rack Power Distribution Unit

Switched Rack Power Distribution Unit Switched Rack Power Distribution Unit AS-216-520-30A-L530 Installation and Quick Start Contents Product Description and Inventory...................... 1 AS-216-520-30A-L530....................... 1 Additional

More information

TECHNICAL SPECIFICATIONS + TECHNICAL OFFER

TECHNICAL SPECIFICATIONS + TECHNICAL OFFER ANNEX II + III : TECHNICAL SPECIFICATIONS + TECHNICAL OFFER Contract title : Supply of Information & Communication Technology Hardware Publication reference: 2017/386304 10/1/1.1/1.2.2a p 1 / Columns 1-2

More information

Overview. Cisco UCS Manager User Documentation

Overview. Cisco UCS Manager User Documentation Cisco UCS Manager User Documentation, page 1 Infrastructure Management Guide, page 2 Cisco Unified Computing System, page 3 Cisco UCS Building Blocks and Connectivity, page 5 Cisco UCS Manager User Documentation

More information

Cisco UCS Mini Software-Defined Storage with StorMagic SvSAN for Remote Offices

Cisco UCS Mini Software-Defined Storage with StorMagic SvSAN for Remote Offices Solution Overview Cisco UCS Mini Software-Defined Storage with StorMagic SvSAN for Remote Offices BENEFITS Cisco UCS and StorMagic SvSAN deliver a solution to the edge: Single addressable storage pool

More information

PDU Inspired by Your Data Center. W IEC PDU Series

PDU Inspired by Your Data Center. W IEC PDU Series PDU Inspired by Your Data Center W IEC PDU Series Intelligent kwh PDU - W series Power Efficiency Management With today s increasing demand for high technology power management solutions, PDU kwh measurement

More information

Cisco Meraki MS400 Series Cloud-Managed Aggregation Switches

Cisco Meraki MS400 Series Cloud-Managed Aggregation Switches Datasheet MS400 Series Cisco Meraki MS400 Series Cloud-Managed Aggregation Switches OVERVIEW The Cisco Meraki MS400 Series brings powerful cloud-managed switching to the aggregation layer. This range of

More information

QuickSpecs. HPE Intelligent Power Distribution Unit (PDU) Overview

QuickSpecs. HPE Intelligent Power Distribution Unit (PDU) Overview Overview You cannot control what you cannot monitor. The new brings state of the art management and control to rack mounted PDUs to prevent over provisioning of power which may restrict growth in your

More information

Dell MD1280 Storage Enclosure Getting Started Guide

Dell MD1280 Storage Enclosure Getting Started Guide Dell MD1280 Storage Enclosure Getting Started Guide Regulatory Model: SP-2584, E11J Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer.

More information

Smart-UPS XL APC Smart-UPS XL 2200VA RM 3U 120V

Smart-UPS XL APC Smart-UPS XL 2200VA RM 3U 120V Smart-UPS XL APC Smart-UPS XL 2200VA RM 3U 120V APC Smart-UPS XL, 1850 Watts / 1850 VA,Input 120V / Output 120V, Interface Port DB-9 RS-232, USB, SmartSlot, Extended runtime model, Rack Height 3 U Includes:

More information

QuickSpecs. HPE Basic Power Distribution Units (PDU) Overview

QuickSpecs. HPE Basic Power Distribution Units (PDU) Overview Overview HPE Basic PDUs are designed to provide reliable and cost effective power distribution for your Hewlett Packard Enterprise and non-hewlett Packard Enterprise IT racks. Offering simple 0U and 1U

More information

FVT Slot Media Converter Chassis w/ Redundant Power User Manual

FVT Slot Media Converter Chassis w/ Redundant Power User Manual FVT-4000 10-Slot Media Converter Chassis w/ Redundant Power User Manual Ver. 1.00-0609 Table of Contents 1. INTRODUCTION... 1 1.1. FEATURES... 1 1.2. PACKAGE CONTENTS... 2 2. HARDWARE DESCRIPTION... 3

More information

Remote Management of Data Center White Space: What to Manage and How? Ashish Moondra Sr. Product Manager Chatsworth Products

Remote Management of Data Center White Space: What to Manage and How? Ashish Moondra Sr. Product Manager Chatsworth Products Remote Management of Data Center White Space: What to Manage and How? Ashish Moondra Sr. Product Manager Chatsworth Products Learning Outcomes Need for Remote Management of Whitespace Understand Elements

More information

StorNext M440 Site Planning Guide

StorNext M440 Site Planning Guide StorNext M440 Contents StorNext M440 Site Planning Guide Included with Your StorNext M440... 1 Professional Installation Requirements. 2 Site Requirements... 2 Shipping Information... 3 StorNext M440 System

More information

Rack PDU Marketing Playbook

Rack PDU Marketing Playbook PLAYBOOK Rack PDU Marketing Playbook Emerson Network Power Rack Power Distribution Unit (Rack PDU) Family Emerson Network Power offers the industry s only complete portfolio of Adaptive, Managed and Basic

More information

Data Sheet FUJITSU PRIMECENTER M2 19-inch Racks

Data Sheet FUJITSU PRIMECENTER M2 19-inch Racks Data Sheet FUJITSU PRIMECENTER M2 19-inch Racks Data Sheet FUJITSU PRIMECENTER M2 19-inch Racks 19-inch Industry Standard Rack Systems The trend to consolidation as a result of virtualization and optimization

More information

Rack 111 Catalog. Designed and Built to Exceed Your Needs.

Rack 111 Catalog. Designed and Built to Exceed Your Needs. Designed and Built to Exceed Your Needs. The Open Frame Server Rack is designed to provide users with a customizable solution engineered to meet a diverse set of rack mounting needs. This EIA server rack

More information

Increasing Data Center Efficiency by Using Improved High Density Power Distribution

Increasing Data Center Efficiency by Using Improved High Density Power Distribution Increasing Data Center Efficiency by Using Improved High Density Power Distribution By Neil Rasmussen White Paper #128 Revision 1 Executive Summary A new approach to power distribution for high density

More information

Premium Online Series

Premium Online Series Premium Online Series UPS backup power systems backup protection with double conversion that isolates and conditions output power for clean, consistent, reliable power features: Permanent connection to

More information

Smart-UPS APC Smart-UPS 750VA USB & Serial RM 1U 120V

Smart-UPS APC Smart-UPS 750VA USB & Serial RM 1U 120V Smart-UPS APC Smart-UPS 750VA USB & Serial RM 1U 120V APC Smart-UPS, 480 Watts / 750 VA,Input 120V / Output 120V, Interface Port DB-9 RS-232, SmartSlot, USB, Rack Height 1 U Includes: CD with software,

More information

Deploying High Power to IT Equipment Racks

Deploying High Power to IT Equipment Racks 2012 Raritan Inc. Table of Contents Overview Page 3 Trends in Data Center Power Deployment Page 3 Drivers for High Power Racks Page 3 Data Center Power Distribution Around the World Page 4 What Is High

More information

AVR Series 120V 750VA 450W Ultra-Compact Line-Interactive UPS with USB port

AVR Series 120V 750VA 450W Ultra-Compact Line-Interactive UPS with USB port AVR Series 120V 750VA 450W Ultra-Compact Line-Interactive UPS with USB port MODEL NUMBER: AVR750U Highlights 750VA ultra-compact 120V line interactive UPS Corrects brownouts and overvoltages from 83V to

More information

SmartPro LCD 120V 1500VA 900W Line- Interactive UPS, AVR, 2U Rack/Tower, LCD, USB, DB9 Serial, 8 Outlets

SmartPro LCD 120V 1500VA 900W Line- Interactive UPS, AVR, 2U Rack/Tower, LCD, USB, DB9 Serial, 8 Outlets SmartPro LCD 120V 1500VA 900W Line- Interactive UPS, AVR, 2U Rack/Tower, LCD, USB, DB9 Serial, 8 Outlets MODEL NUMBER: SMART1500LCD Highlights Supports a half-load (450W) up to 11.8 min. during power outage

More information

Cisco Unified Computing System Delivering on Cisco's Unified Computing Vision

Cisco Unified Computing System Delivering on Cisco's Unified Computing Vision Cisco Unified Computing System Delivering on Cisco's Unified Computing Vision At-A-Glance Unified Computing Realized Today, IT organizations assemble their data center environments from individual components.

More information

SmartOnline 120V 3kVA 2.7kW On-Line Double- Conversion UPS, 2U Rack/Tower, Extended Run, Network Card Option, ENERGY STAR

SmartOnline 120V 3kVA 2.7kW On-Line Double- Conversion UPS, 2U Rack/Tower, Extended Run, Network Card Option, ENERGY STAR SmartOnline 120V 3kVA 2.7kW On-Line Double- Conversion UPS, 2U Rack/Tower, Extended Run, Network Card Option, ENERGY STAR MODEL NUMBER: SU3000RTXL2U Highlights Zero transfer time between AC power and battery

More information

RittalXpress TS IT Enclosure Assemble-to-Order Program

RittalXpress TS IT Enclosure Assemble-to-Order Program RittalXpress TS IT Enclosure Assemble-to-Order Program DESIGN YOUR DATA CENTER BY THE NUMBERS. Count down to success: 4, 3, 2, 1... Complete four easy steps, your order can be shipped in three days and

More information

Data Sheet FUJITSU Server PRIMERGY CX400 M4 Scale out Server

Data Sheet FUJITSU Server PRIMERGY CX400 M4 Scale out Server Data Sheet FUJITSU Server PRIMERGY CX400 M4 Scale out Server Data Sheet FUJITSU Server PRIMERGY CX400 M4 Scale out Server Workload-specific power in a modular form factor FUJITSU Server PRIMERGY will give

More information

Server Technology Inc.

Server Technology Inc. Server Technology Inc. Power Efficiency Gains by Deploying 415 VAC Power Distribution in North American Data Centers White Paper STI-100-008 2011-Sept-22 Headquarters Server Technology, Inc. 1040 Sandhill

More information

QuickSpecs. HP Intelligent Power Distribution Unit (ipdu) Overview

QuickSpecs. HP Intelligent Power Distribution Unit (ipdu) Overview Overview You cannot control what you cannot monitor. The new brings state of the art management and control to rack mounted power distribution units (PDU) to prevent over provisioning of power from restricting

More information

Data Sheet FUJITSU Server PRIMERGY BX900 S2 Blade Server

Data Sheet FUJITSU Server PRIMERGY BX900 S2 Blade Server Data Sheet FUJITSU Server PRIMERGY BX900 S2 Blade Server Data Sheet FUJITSU Server PRIMERGY BX900 S2 Blade Server For data centers with dynamic environments FUJITSU Server PRIMERGY will give you the servers

More information

SmartZone Rack Energy Kits Energy and Environmental Monitoring for Small Data Centers

SmartZone Rack Energy Kits Energy and Environmental Monitoring for Small Data Centers SmartZone Rack Energy Kits Energy and Environmental Monitoring for Small Data Centers SmartZone Rack Energy Kits Energy and Environmental Monitoring for Small Data Centers SmartZone Rack Energy Kits Features:

More information

DCIM Data Center Infrastructure Management

DCIM Data Center Infrastructure Management DCIM Data Center Infrastructure Management Part 3 Operational Management Moves Adds and Changes & Electrical Infrastructure November 5, 2013 Presented by Julius Neudorfer Sponsored by Today s Topics Operational

More information

SmartMod Intelligent, Integrated Infrastructure for the Data Center

SmartMod Intelligent, Integrated Infrastructure for the Data Center SmartMod Intelligent, Integrated Infrastructure for the Data Center Deploy a High-Capacity, Efficient and Secure Infrastructure in Just Months Building a new data center in a short timeframe is nearly

More information

Intelligent Power Distribution

Intelligent Power Distribution Eaton epdu Intelligent Power Distribution Maximise and manage your rack power Maximise and manage your rack power Two key trends have emerged in the data centre: the demand from today s IT equipment for

More information

Intelligent-Remote Monitoring (3) Power Circuit Environmental Port (4) Power Outlet Level (5) PDU De-Rated Power Watts (W) PDU Nominal.

Intelligent-Remote Monitoring (3) Power Circuit Environmental Port (4) Power Outlet Level (5) PDU De-Rated Power Watts (W) PDU Nominal. Enclosure Power Distribution Units (PDUs) (continued) PDU Selection: Basic, with ocal Monitoring and Intelligent Highly secure access with admin, control and view-only accounts Intuitive Ethernet-based

More information

Dell SC7020 Storage Controller Getting Started Guide

Dell SC7020 Storage Controller Getting Started Guide Dell SC7020 Storage Controller Getting Started Guide Regulatory Model: E03T Regulatory Type: E03T001 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better

More information

IBM UPS5000 HV Uninterruptible Power Supply for IBM System x Product Guide

IBM UPS5000 HV Uninterruptible Power Supply for IBM System x Product Guide IBM UPS5000 HV Uninterruptible Power Supply for IBM System x Product Guide The IBM UPS5000 HV is a 5 KVA rack-mountable uninterruptible power supply (UPS) that utilizes advanced backup power technology

More information

Xcellis Workflow Extender (R520) Site Planning Guide

Xcellis Workflow Extender (R520) Site Planning Guide Xcellis Workflow Extender Contents Xcellis Workflow Extender (R520) Site Planning Guide Product Overview Product Overview... 1 Installation Requirements... 2 Rack Compatibility... 2 Setup... 2 Installation

More information

20 Amp PanView iq TM (PViQ TM ) Switched and Environmental Power Outlet Units

20 Amp PanView iq TM (PViQ TM ) Switched and Environmental Power Outlet Units 20 Amp PanView iq TM (PViQ TM ) Switched and Environmental Power Outlet Units specifications PViQ Power Outlet Units shall integrate with the Panduit PIM Software Platform to enable intelligent management

More information

T1000 G2 and T1500 G2 1. Battery Compartment 1. Battery Compartment 2. LED display 2. LED display HP T1500 UPS INTL HP T1500 UPS JPN/TWN

T1000 G2 and T1500 G2 1. Battery Compartment 1. Battery Compartment 2. LED display 2. LED display HP T1500 UPS INTL HP T1500 UPS JPN/TWN Overview The Tower UPS "G2" models are the next generation HP tower UPSs with USB support. The new models are the UPS T1000 G2, T1500 G2 and R/T2200 G2 respectively. These new UPSs are designed to provide

More information