Air Circuit Breakers. 1/2 Introduction

Size: px
Start display at page:

Download "Air Circuit Breakers. 1/2 Introduction"

Transcription

1 /2 Introduction 3WL air circuit breakers/ non-automatic air circuit breakers /5 Introduction Up to 6300 A (AC), IEC /6 Introduction /9 General data /6 3-pole, fixed-mounted versions /23 3-pole, withdrawable versions /30 4-pole, fixed-mounted versions /37 4-pole, withdrawable versions /44 Options /5 Accessories and spare parts Up to 4000 A (DC), IEC /73 General data /76 3- and 4-pole, fixed-mounted versions /77 3- and 4-pole, withdrawable versions /79 Accessories and spare parts For further information on 3WL5, see Catalog LV 6 3WL5 air circuit breakers/ non-automatic air circuit breakers /8 Introduction /83 General data Up to 5000 A (AC) acc. to UL 489/IEC /90 3-pole, fixed-mounted versions /9 3-pole, withdrawable versions /92 4-pole, fixed-mounted versions /93 4-pole, withdrawable versions Up to 3200 A (DC) acc. to UL 489B/IEC /94 Fixed-mounted versions /95 Options /0 Accessories and spare parts Ch. 2 3KC ATC5300 and ATC300 transfer control devices For further technical product information: Direct reference to the products in the Industry Mall from the selection and ordering data tables: Article No. product? Article No. 3VA2025-5HL36-0AA0 Paper catalog: To get more product information enter the Web address plus Article No. PDF catalog: Get more product information with just a mouse click. Configuration Manual Article No.: 3ZW02-3WL-0AC Siemens Industry Online Support: lowvoltage/productsupport, Entry type: Application example Certificate Characteristic Download FAQ Manual Product note Software archive Technical data Siemens LV 0 206/207

2 Introduction Overview Devices Page Applications/ Individual components 3WL air circuit breakers/ non-automatic air circuit breakers 3WL /6... /43 3WL5 As incoming-feeder, distribution, tie, and outgoing-feeder circuit breakers in electrical installations. For switching and protecting motors, capacitors, generators, transformers, busbars and cables. Standards IEC , climate-proof acc. to IEC CCC Used in Non-residential buildings Residential buildings Industry 3WL non-automatic air circuit breakers up to 4000 A (DC), IEC /76... /78 As incoming-feeder, distribution, tie, and outgoing-feeder circuit breakers in electrical installations. For switching and protecting busbars and cables. IEC , climate-proof acc. to IEC CCC NSE0_00992b 3WL5 air circuit breakers up to 5000 A (AC), UL 489/IEC WL5 air circuit breakers up to 3200 A (DC), UL 489B/IEC Protective device with device holder and optional measurement function (ETU) /90... /93 As incoming-feeder, distribution, tie, and outgoing-feeder circuit breakers in electrical installations. For switching and protecting motors, capacitors, generators, transformers, busbars and cables. /94 As incoming-feeder, distribution, tie, and outgoing-feeder circuit breakers in electrical installations. For switching and protecting busbars and cables. UL 489, UL 489B, IEC IEC appendix F/CISPR /22 Class B DIN VDE 0660 Part 0 climate-proof acc. to IEC CCC UL 489, UL 489B, IEC IEC appendix F/CISPR /22 Class B DIN VDE 0660 Part 0 climate-proof acc. to IEC CCC /58 /04 Electronic Trip Unit with protection As for circuit breakers functions LI, LSI, LSING and LSIN(G), with or without measurement function Plus Rating Plugs /58 /04 For rated currents I n from 250 A to 6300 A. The maximum rated current of the circuit breaker must not be exceeded. As for circuit breakers Ground-fault modules /58 /04 With alarm and tripping As for circuit breakers NSE0_0027a Displays /58 /04 4-line displays for ETU45B As for circuit breakers NSE0_0609 Current transformers for N conductor protection /58 /04 Internal transformers for N conductors, external transformers for N conductors As for circuit breakers NSE0_00990a EMC filters /58 /04 Common-mode interference suppressor filters More accessories for Electronic Trip Units /59 /05 Sealable and lockable covers, automatic reset of the reclosing lockout, remote reset solenoid, retrofittable internal CubicleBUS wiring, retrofittable internal wiring for connection of external N and G transformers As for circuit breakers As for circuit breakers NSE0_00999a /2 Siemens LV 0 206/207

3 Devices Page Applications/ Individual components NSE0_00987 NSE0_ WL 3WL5 Locking devices /59 /05 Interlocking set for mechanical ON/OFF, locking devices against unauthorized closing in operator panels/for withdrawable circuit breakers, locking devices for operating mechanism handle with padlock, locking devices to prevent movement of the withdrawable circuit breakers, interlocking systems Locking mechanisms /60 /06 To prevent movement of the withdrawable circuit breakers into disconnected position, to prevent opening of the cabinet door in ON position, to prevent opening of the cabinet door, to prevent movement with the cabinet door open Interlocks /6 /07 Mutual mechanical interlocking, couplings on the circuit breaker (with ring) for mutual interlocking, Bowden wire Standards Introduction Used in Non-residential buildings Residential buildings Industry As for circuit breakers As for circuit breakers As for circuit breakers NSE0_ KC ATC5300 and ATC300 transfer control devices Ch. 2 Ch. 2 The 3KC ATC5300 and ATC300 transfer control devices, equipped with two circuit breakers with motorized operating mechanism, serve as a transfer system that automatically or manually switches between two power supply systems in low-voltage power distribution applications. IEC DIN VDE UL 508 CSA 22.2 No. 4 Test devices /6 /07 Manual tester Release 2 for Electronic Trip Units, function testers As for circuit breakers Capacitor storage devices /6 /07 For shunt releases As for circuit breakers NSE0_00995a Indicators, control elements /62 /08 Ready-to-close signaling switches, signaling switches, tripped signaling switches, operating cycles counters, stored energy status signaling switches, position signaling switches for guide frames, electric ON buttons, motor shutdown switches, EMERGENCY-STOP buttons As for circuit breakers NSE0_0269 Auxiliary conductor connections /63 /09 Male connectors for circuit breakers, extension for 000 V male connector versions, male connectors and extension for 000 V, auxiliary supply connectors for circuit breakers or guide frames, coding kits, sliding contacts for guide frames, blanking blocks for circuit breakers Auxiliary release /64 /0 Closing solenoids/shunt releases, undervoltage releases As for circuit breakers As for circuit breakers Operating mechanisms /64 /0 Motorized operating mechanism As for circuit breakers Auxiliary contacts /64 /0 Auxiliary switch blocks As for circuit breakers Door sealing frames, hoods, shutters /65 / Door sealing frames, IP55 protective covers, shutters As for circuit breakers Arc chutes /65 Arc chutes, arc chute covers As for circuit breakers Siemens LV 0 206/207 /3

4 Introduction Devices Page Applications/ Individual components NSE0_008a Coding for withdrawable version 3WL 3WL5 /65 / By customer, for 36 coding variants As for circuit breakers Grounding connection /66 Grounding connection between the guide frame and the withdrawable circuit breaker, contacting modules for withdrawable circuit breakers Standards Used in Non-residential buildings Residential buildings Industry As for circuit breakers Device CubicleBus PROFIBUS DP Support brackets /66 /2 For mounting fixed-mounted circuit breakers on vertical plane CubicleBUS modules /66 /2 Digital and analog input and output modules, Zone Selective Interlocking modules Parameterization systems /66 /2 Breaker Data Adapter (BDA), BDA Plus, connection cables for BDA Plus, powerconfig parameterization software Accessories for communications /67 /3 Factory-fitted cables for CubicleBUS modules, SENTRON manuals for communication solutions, voltage transformers Retrofitting and spare parts /67 /3 PROFIBUS retrofit kits, COM5 PROFIBUS modules, COM6 MODBUS modules, MODBUS IEC retrofit kits, Breaker Status Sensor (BSS), measurement function Plus As for circuit breakers As for circuit breakers As for circuit breakers As for circuit breakers As for circuit breakers NSE0_0025 Main conductor connections, fixed-mounted, main conductor connections, withdrawable /68, /69 /4, /5 Front-accessible main connections with double or single hole, rear vertical main connections, rear horizontal main connections, circuit connecting flanges, supports for front and DIN connecting bars As for circuit breakers NSE0_000 Conversion sets /70 /5 Conversion set for converting fixedmounted circuit breakers into withdrawable circuit breakers Main contact elements /70 For replacement of the main contacts during maintenance and thus to boost the useful life of the breaker. As for circuit breakers As for circuit breakers NSE0_002 Withdrawable shortcircuiting, grounding and bridging units /7 For use during maintenance work on the system. As for circuit breakers /4 Siemens LV 0 206/207

5 3WL /Non-Automatic Overview 3WL air circuit breakers offer highly flexible application and consistent communication capability. With the 3WL circuit breakers, just three sizes cover a performance range of 630 A to Introduction 6300 A. All models are characterized by the same design, the same operation and the same comprehensive accessories NSE0_0887d $ Guide frame (page /52 to page /57) % Main circuit connection front, flange, horizontal, vertical (page /49, /68 and /69) & Position signaling switch (page /47 and /62) ( Grounding connection, leading (page /66) ) Shutters (page /47 and /65) * COM5 PROFIBUS module or COM6 MODBUS module (page /47 and /67) + External CubicleBUS modules (page /66), Closing coil, auxiliary release (page /44, /46 and /64) - Auxiliary conductor plug-in system (page /48 and /63). Auxiliary switch block (page /44 and /64) / Door sealing frame (page /46 and /65) 0 Interlocking set for mechanical ON/OFF (page /59) Transparent panel, function insert (page /59) 2 EMERGENCY-STOP pushbutton, key operated (page /62) 3 Motorized operating mechanism (page /46 und /64) 4 Operating cycles counter (page /46 and /62) 5 Breaker Status Sensor (BSS) (page /47 and /67) 6 Protective device with device holder, Electronic Trip Unit (ETU) (page /58) 7 Remote reset solenoid (page /46 and /59) 8 Breaker Data Adapter (BDA Plus) (page /66) 9 Four-line display (page /58) : Ground-fault protection module (page /58) ; Rating plug (page /45 and /58) < Measurement function module (page /47 and /58) = Air circuit breaker (page /6 to /43) Siemens LV 0 206/207 /5

6 3WL /Non-Automatic Introduction Overview Communication-capable circuit breakers (with ETU45B or ETU76B Electronic Trip Unit) 20 Ethernet 8 9 PROFIBUS PROFINET VA-line 3VA-line NSE0_005n 8 CubicleBUS VA molded case circuit breakers 3VL molded case circuit breakers Electronic trip unit ETU / LCD ETU COM800 breaker data server COM00 breaker data server COM20 Release 2 PROFIBUS module including Zone Selective Interlocking BDA Plus with Ethernet interface 3WL air circuit breaker COM5 PROFIBUS module Breaker status sensor (BSS) Electronic trip unit (ETU) Measurement function Plus Zone Selective Interlocking module Digital output module with relay contacts Digital output module with relay contacts, configurable Analog output modules Digital input modules Configuration software powerconfig V2.3 and higher PLC, e.g. SIMATIC S7 E.g. SIMATIC powerrate 7KM PAC measuring devices /6 Siemens LV 0 206/207

7 3WL /Non-Automatic Introduction Ethernet MODBUS TCP RS 485 with MODBUS RTU 3VA-line 3VA-line I20_ VA molded case circuit breakers 3WL air circuit breaker COM6 MODBUS module 3VL molded case circuit breaker COM2 MODBUS module COM800 breaker data server COM00 breaker data server 7KM PAC4200 measuring device 7KM PAC300 measuring device 7KM PAC3200 measuring device powerconfig configuration software from V2.3 Characteristics Coordinated communication concept using the PROFIBUS DP or MODBUS, ranging from 6 A to 6300 A with 3VL molded case circuit breakers and 3WL air circuit breakers The high level of modularity of circuit breakers and accessories allows easy retrofitting of all communication components Significant additional benefits for the switchboard due to the possibility of linking up external input and output modules to the circuit breaker-internal CubicleBUS of the 3WL air circuit breaker Innovative software products for parameterization, operation, monitoring, and diagnostics of circuit breakers, both locally or via PROFIBUS DP, MODBUS or Ethernet/Intranet/Internet Complete integration of the circuit breakers into the Totally Integrated Power and Totally Integrated Automation solutions Communication: For air circuit breakers with optional communication function (ETU45B or ETU76B Electronic Trip Unit), see page /6 to page /43. For accessories, see page /66 and page /67. For more information, see chapter "Measuring Devices and Power Monitoring" and see chapter "Monitoring Devices". For configuring information, also see Configuration Manual "" at lowvoltage/manuals. Siemens LV 0 206/207 /7

8 3WL /Non-Automatic Introduction Benefits Low space requirements The 3WL air circuit breakers require very little space. I devices (up to 2000 A) fit into a 400 mm wide switchboard panel. III devices (up to 6300 A) are the smallest of their kind and with their construction width of 704 mm fit into an 800 mm wide switchboard panel. Modular design Components such as auxiliary releases, motorized operating mechanisms, Electronic Trip Units, current sensors, auxiliary circuit signaling switches, automatic reset devices, interlocks and engagement operating mechanisms can all be exchanged or retrofitted at a later stage, thus allowing the circuit breaker to be adapted to new, changing requirements. The main contact elements can all be replaced in order to increase the endurance of the circuit breaker. Retrofittable modules for Electronic Trip Units Modularity is one of the main features of the new 3WL circuit breakers. Special LCDs, ground-fault modules, rating plugs and communication modules for the Electronic Trip Units are available for fast and easy retrofitting and adaptation to changing requirements. Application As incoming-feeder, distribution, tie, and outgoing-feeder circuit breakers in electrical installations. For switching and protecting motors, capacitors, generators, transformers, busbars and cables. When connected to an electronic I&C system, the air circuit breakers offer a wide range of options for monitoring network events. Air circuit breakers belong to the SENTRON product family of protection, switching, measuring and monitoring devices and can be used in applications between 6 A and 6300 A. The AC devices are available as circuit breakers and non-automatic air circuit breakers. DC devices are only available as non-automatic air circuit breakers. Communication/measuring functions The use of modern communication-capable circuit breakers opens up completely new possibilities in terms of start-up, parameterization, diagnostics, maintenance and operation. This allows many different ways of reducing costs and improving productivity in industrial plants, buildings and infrastructure projects to be achieved: Fast and reliable parameterization Timely information and response can prevent plant stoppages Effective diagnostics management Measured values are the basis for efficient load management, for drawing up power demand profiles and for allocating energy to cost centers Preventive maintenance reduces the risk of expensive plant downtimes Measurement function with a very wide range of measured values, such as current, voltage, energy, power etc. Can be used in 690 V networks Standards 3WL air circuit breakers comply with: IEC IEC Appendix F / CISPR /22 Class B Climate-proof according to IEC For further standards, see chapter "Appendix". /8 Siemens LV 0 206/207

9 Technical specifications Siemens AG 206 3WL /Non-Automatic General data I II Type... 3WL0 3WL2 3WL6 3WL20 3WL208 3WL20 3WL22 3WL26 Number of poles 3-pole, 4-pole Rated current I n at 40 C, at 50/60 Hz Main conductor N conductor (only on 4-pole versions) Rated operational voltage U e at 50/60 Hz (000 V version, see page /45 "Options") A A V AC /000 ) Use of trip units from -20 C. 2) ETU76B with graphics display can be used up to max. 55 C. 3) At breaking capacity H: 600 A to 70 C. 4) Make-time through closing solenoid for synchronization purposes (short-time excited) 50 ms. 5) Maintenance means: replace main contact elements and arc chutes (see Operating Manual) / / / / / /000 Rated insulation voltage U i V AC Rated impulse withstand voltage U imp Main conducting paths Auxiliary circuits Control circuits 9) kv kv kv Isolating function acc. to EN Yes Yes Yes Yes Yes Yes Yes Yes Utilization category B Permissible ambient temperature During operation (in operation with LCD max. 55 C) ) Storage Permissible load for withdrawable versions at rear horizontal main connections Up to 55 C (Cu bare) Up to 60 C (Cu bare) 2) Up to 70 C (Cu black painted) 2) C 25/+70 C 40/+70 A A A /+70 40/ /+70 40/ ) 25/+70 40/ /+70 40/ /+70 40/ /+70 40/ Rated rotor operational voltage U er V Power loss at I n With 3-phase symmetrical load Fixed-mounted circuit breakers Withdrawable circuit breakers Switching times Make time Opening time Electrical make time (through closing solenoid) 4) Electrical opening time (through shunt release) Electrical opening time (instantaneous undervoltage ms release) Opening time due to ETU, instantaneous short-circuit ms release Service life: Breaking capacity N and S, 3-/4-pole Mechanical (without maintenance) Operating cycles W 00 W 95 ms ms ms ms Mechanical (with maintenance) 5) Operating cycles Electrical (without maintenance) Operating cycles 000 V version, electrical (without maintenance) Oper. cycles 50 V version, electrical (without maintenance) Oper. cycles Electrical (with maintenance) 5) Operating cycles Service life: Breaking capacity H, 3-pole Mechanical (without maintenance) Operating cycles Mechanical (with maintenance) 5) Operating cycles Electrical (without maintenance) Operating cycles V version, electrical (without maintenance) Oper. cycles V version, electrical (without maintenance) Oper. cycles Electrical (with maintenance) 5)6) Operating cycles Service life: Breaking capacity H, 4-pole Mechanical (without maintenance) Operating cycles Mechanical (with maintenance) 5) Operating cycles Electrical (without maintenance) Operating cycles V version, electrical (without maintenance) Oper. cycles V version, electrical (without maintenance) Oper. cycles Electrical (with maintenance) 5)6) Operating cycles /000 25/+70 40/ ) Replacement of the main contact elements of circuit breakers size I with breaking capacity H is only possible at the factory. 7) Minimum interval time between 2 tripping operations. 8) 3-pole switching with breaking capacity N and S: 45/h. 9) Motorized operating mechanism U imp =.2 kv Service life: Breaking capacity C Mechanical (without maintenance) Operating cycles Mechanical (with maintenance) 5) Operating cycles Electrical (without maintenance) Operating cycles Electrical (with maintenance) 5) Operating cycles Switching frequency 7) 690 V version 000 V version 50 V version /h /h /h 60 8) 60 8) 60 8) ) ) ) ) Minimum interval between tripping operation by electronic trip unit and next making operation of the circuit breaker (only with autom. mechanical resetting of the lockout device). Minimum interval between On-Off or Off-On switching operations. ms Siemens LV 0 206/207 /9

10 3WL /Non-Automatic General data I II Type... 3WL0 3WL2 3WL6 3WL20 3WL208 3WL20 3WL22 3WL26 Mounting position and/or Dhmax. = mm Degree of protection Main conductor minimum cross-sections Auxiliary conductors (Cu) Max. number Auxiliary conductors cross-section (solid/stranded) Copper bars, bare Copper bars, painted black Standard connection = strain-relief clamp Without end sleeve With end sleeve acc. to DIN Part 2 With twin end sleeve Optional connection = tension spring Without end sleeve With end sleeve acc. to DIN Part 2 Unit(s) mm 2 Unit(s) mm 2 IP20 without cabinet door, IP4 with door sealing frame, IP55 with cover mm 2 (AWG 20) mm 2 (AWG 6); 2.5 mm 2 (AWG 4) 0.5 mm 2 (AWG 20)....5 mm 2 (AWG 6) mm 2 (AWG 20) mm 2 (AWG 6) mm 2 (AWG 20) mm 2 (AWG 4) mm 2 (AWG 20) mm 2 (AWG 6) Position signaling switches Tension spring terminals 0.5 mm 2 (AWG 20) mm 2 (AWG 4) s Dimensions 3-/4-pole H W 3-pole 4-pole D Fixed-mounted circuit breakers Withdrawable circuit breakers Guide frames Fixed-mounted circuit breakers Withdrawable circuit breakers Guide frames NSE0_0006a NSE0_00062a W mm 320/40 460/590 Fixed-mounted H mm D mm Withdrawable H mm D mm NSE0_ NSS0_00535 /0 Siemens LV 0 206/207

11 3WL /Non-Automatic II III General data Type 3WL220 3WL225 3WL232 3WL240 3WL340 3WL350 3WL363 Number of poles 3-pole, 4-pole Rated current I n at 40 C, at 50/60 Hz Main conductor N conductor (only on 4-pole versions) Rated operational voltage U e at 50/60 Hz (000 V version, see page /45 "Options") A 2000 A 2000 V AC / / / / /000 Rated insulation voltage U i V AC Rated impulse withstand voltage U imp Main conducting paths Auxiliary circuits Control circuits 0) kv 2 kv 4 kv 2.5 Isolating function acc. to EN Yes Yes Yes Yes Yes Yes Yes Utilization category Permissible ambient temperature During operation (in operation with LCD max. 55 C) ) Storage B C 25/+70 C 40/ /+70 40/ /+70 40/ /+70 40/ /+70 40/ /+70 40/+70 Permissible load for withdrawable versions 2) 4) Up to 55 C (Cu bare) Up to 60 C (Cu bare) Up to 70 C (Cu painted black) A A A Rated rotor operational voltage U er V / /+70 40/+70 Power loss at I n With 3-phase symmetrical load Fixed-mounted circuit breakers Withdrawable circuit breakers Switching times Make time Opening time Electrical make time (through closing solenoid) 5) Electrical opening time (through shunt release) Electrical opening time (instantaneous undervoltage release) Opening time due to ETU, instantaneous short-circuit release Service life: Breaking capacity N, S and H ) Mechanical (without maintenance) Mechanical (with maintenance) 6) Electrical (without maintenance) up to 690 V 000 V version, electrical (without maintenance) 50 V version, electrical 7) (without maintenance) Electrical (with maintenance) 6) Service life: Breaking capacity C Mechanical (without maintenance) Mechanical (with maintenance) 6) Electrical (without maintenance) up to 690 V Electrical (without maintenance) up to 50 V Electrical (with maintenance) up to 690 V 6) ) Use of trip units from -20 C. 2) 4000 A, size II in fixed-mounted version, 3-pole. 4) ETU76B with graphics display can be used up to max. 55 C. 5) Make-time through closing solenoid for synchronization purposes (short-time excited) 50 ms. W 80 W 320 ms ms ms ms ms ms Operating cycles Operating cycles Operating cycles Operating cycles Operating cycles Operating cycles Operating cycles Operating cycles Operating cycles Operating cycles Operating cycles Switching frequency 8) 690 V version 000 V version 50 V version 7) Minimum interval between tripping operation by electronic trip unit and next making operation of the circuit breaker (only with autom. mechanical resetting of the lockout device) Minimum interval between On-Off or Off-On switching operations. /h /h /h ) ) ) ) ms ) Maintenance means: replace main contact elements and arc chutes (see Operating Manual). 7) II with order code "A5" and size III: data for very high breaking capacity. 8) Minimum interval time between 2 tripping operations. 9) 3-pole switching with breaking capacity N and S: 45/h ) Motorized operating mechanism U imp =.2 kv ) 000 V and 50 V versions only in the case of H breaking capacity Siemens LV 0 206/207 /

12 3WL /Non-Automatic General data II III Type 3WL220 3WL225 3WL232 3WL240 3WL340 3WL350 3WL363 Mounting position and/ or Dhmax. = mm Degree of protection Main conductor minimum cross-sections Auxiliary conductors (Cu) Max. number of auxiliary conductors cross-section (solid/stranded) Position signaling switches s Dimensions 3-/4-pole H W 3-pole 4-pole D Copper bars, bare Copper bars, painted black Standard connection = strain-relief clamp Without end sleeve With end sleeve acc. to DIN Part 2 With twin end sleeve Unit(s) mm 2 Unit(s) mm 2 Optional connection = tension spring Without end sleeve With end sleeve acc. to DIN Part 2 IP20 without cabinet door, IP4 with door sealing frame, IP55 with cover ) 4 x 00 x x 00 x mm 2 (AWG 20) mm 2 (AWG 6); 2.5 mm 2 (AWG 4) 0.5 mm 2 (AWG 20)....5 mm 2 (AWG 6) mm 2 (AWG 20) mm 2 (AWG 6) mm 2 (AWG 20) mm 2 (AWG 4) mm 2 (AWG 20) mm 2 (AWG 6) Tension spring terminals 0.5 mm 2 (AWG 20) mm 2 (AWG 4) Fixed-mounted circuit breakers Withdrawable circuit breakers Guide frames Fixed-mounted circuit breakers Withdrawable circuit breakers Guide frames NSE0_0006a NSE0_00062a W mm 460/ /94 Fixed-mounted H mm D mm Withdrawable H mm D mm NSE0_ x 20 x NSS0_00535 ) Minimum main conductor cross-sections for 4-pole withdrawable circuit breakers: 4 x 20 x 0 mm. /2 Siemens LV 0 206/207

13 3WL /Non-Automatic Breaking capacity I II III Type 3WL 3WL2 3WL3 General data Breaking capacity N S H N S H C H C C N S H N S H C H C C 3-pole 4-pole Short-circuit breaking capacity Rated operational voltage U e up to 45 V AC I cu ka I cs ka I cm ka Rated operational voltage U e up to 500 V AC I cu ka I cs ka I cm ka Rated operational voltage U e up to 690 V AC I cu ka I cs ka I cm ka Rated operational voltage U e up to 000 V/50 V AC I cu ka 50 5) ) 70 4) I cs ka 50 5) ) 70 4) I cm ka 05 5) ) 54 4) Rated short-time withstand current 3) I cw 0.5 s ka s ka s ka ) /70 2) s ka ) /65 2) Conditional rated short-circuit breaking capacity I cc of the non-automatic air circuit breakers Up to 500 V AC ka Up to 690 V AC ka Up to 000 V/50 V AC ka 50 5) 50 4) 50 6) 70 4) 70 4) N S H C DC Note: Circuit breakers with ECO breaking capacity N Circuit breakers with standard breaking capacity S Circuit breakers with high breaking capacity H Circuit breakers with very high breaking capacity C Non-automatic air circuit breakers with DC breaking capacity These breaking capacities are indicated in the corresponding tables by the symbols shown on orange bacrounds. For further technical specifications, see the configuration manual "". Free download from: lowvoltage/manuals Abbreviations* (functions) English long text Explanation L Long Time Delay Overload protection S Short Time Delay Short-circuit protection (short-time delayed) I Instantaneous Short-circuit protection (instantaneous) N Neutral Protection Neutral conductor protection G Ground Fault Ground-fault protection * Designations according to IEC , Appendix K. ) II with I n max 2500 A. 2) II with I n max = 3200 A and I n max = 4000 A. 3) At a rated voltage of 690 V, the I cw value of the circuit breaker cannot be greater than the I cu or I cs value at 690 V. 4) Rated operational voltage U e = 50 V. 5) Values also apply to 690 V + 20 % version with Z-option "A6". 6) Rated operational voltage U e = 000 V Siemens LV 0 206/207 /3

14 4 C C 4 E Siemens AG 206 3WL /Non-Automatic General data 5 - & & & > 5 - & & ' = Protection functions ETU5B ETU25B ETU27B Parameterization by D D D & S Function overview of the electronic trip system Overload protection Function can be switched on/off Setting range I R = I n L Switchable overload protection (I 2 t- or I 4 t-dependent function) Setting range for time-lag class t R at I 2 t 0 s fixed 0 s fixed 0 s fixed Setting range for time-lag class t R at I t 4 Thermal image can be switched on/off Phase failure sensitivity At t sd = 20 ms (M) At t sd = 20 ms (M) N-conductor protection N Function can be switched on/off N conductor setting range I N = I n... Short-time delayed short-circuit protection Function can be switched on/off Setting range I sd = I n Setting range for delay time t S sd 0-M ms 0-M ms Switchable short-time delayed short-circuit protection (I 2 t-dependent function) Setting range for delay time t sd at I 2 t ZSI function Instantaneous short-circuit protection I Function can be switched on/off Setting range I i = I n Fixed for I i 20 I n, max. 50 ka Fixed for I i 20 I n, max. 50 ka Ground-fault protection Fixed mounted Tripping and alarm functions Tripping function can be switched on/off Alarm function can be switched on/off Detection of the ground-fault current through summation current formation with internal or external N conductor transformer Detection of ground-fault current through external G current transformer Setting range of the operating current I g for tripping A-B-C-D-E Setting range of the operating current I g for alarm Setting range of the delay time t g ms Switchable ground-fault protection characteristic curve (I 2 t-dependent function) Setting range for delay time t g at I 2 t ZSI-G function Parameter set changeover Switchable between parameter set A and B LCD Alphanumeric LCD (4-line) Graphical LCD (24 V, external power supply required) Communication CubicleBUS integrated Communications capability via PROFIBUS DP Measuring function Metering capability with measuring function Plus LED display Electronic trip unit active Alarm ETU fault L tripping operation S tripping operation I tripping operation N tripping operation NSE0_00890 G tripping operation G alarm Tripping operation as a result of extended protection function Communication Signals from signaling switches with external CubicleBUS modules (relays) Overload warning Load shedding, load absorbing Leading signal overload trip 200 ms Temperature alarm Phase unbalance Instantaneous short-circuit trip Short-time delayed short-circuit trip Overload trip NSE0_0089 Neutral conductor trip Ground-fault protection trip Ground-fault alarm Auxiliary relay ETU fault Delay time figures given in ms. M = Motor protection, corresponds to 20 ms. D = Rotary coding switch D & S = Rotary coding and slide switch K = Communication M/K = Menu/Communication Available. Not available. Optional. For setting range of the operating current I g, see page /5. /4 Siemens LV 0 206/207

15 3WL /Non-Automatic Protection functions ETU45B ETU76B Parameterization by D & S M/K Function overview of the electronic trip system Overload protection Function can be switched on/off Setting range I R = I n Switchable overload protection (I 2 t- or I 4 t-dependent function) Setting range for time-lag class t R at I 2 t s s Setting range for time-lag class t R at I 4 t s... 5 s Thermal image can be switched on/off Phase failure sensitivity At t sd = 20 ms (M) (on/off) N-conductor protection Function can be switched on/off N conductor setting range I N = I n Short-time delayed short-circuit protection Function can be switched on/off Setting range I sd = I n I n I cw Setting range for delay time t sd M ms M ms Switchable short-time delayed short-circuit protection (I 2 t-dependent function) Setting range for delay time t sd at I 2 t ms ms ZSI function By CubicleBUS module By CubicleBUS module Instantaneous short-circuit protection Function can be switched on/off Setting range I i = I n x I cs.5 I n I cs Ground-fault protection Module can be retrofitted Module can be retrofitted Tripping and alarm functions Tripping function can be switched on/off Alarm function can be switched on/off Detection of the ground-fault current through summation current formation with internal or external N conductor transformer Detection of ground-fault current through external current transformer Setting range of the operating current I g for tripping A-B-C-D-E A... E Setting range of the operating current I g for alarm A-B-C-D-E A... E Setting range of the delay time t g ms ms Switchable ground-fault protection characteristic curve (I 2 t-dependent function) Setting range for delay time t g at I 2 t ms ms ZSI-G function By CubicleBUS module By CubicleBUS module Parameter set changeover Switchable between parameter set A and B LCD Alphanumeric LCD (4-line) Graphical LCD (24 V, external power supply required) Communication CubicleBUS integrated Communications capability via PROFIBUS DP Measuring function Metering capability with measuring function Plus LED display Electronic trip unit active Alarm ETU fault L tripping operation S tripping operation I tripping operation N tripping operation G tripping operation (Only with ground-fault protection module) (Only with ground-fault protection module) G alarm (Only with ground-fault protection module) (Only with ground-fault protection module) Tripping operation as a result of extended protection functions Communication Signals from signaling switches with external CubicleBUS modules (relays) Overload warning Load shedding, load absorbing Leading signal overload trip 200 ms Temperature alarm Phase unbalance Instantaneous short-circuit trip Short-time delayed short-circuit trip Overload trip Neutral conductor trip Ground-fault protection trip (Only with ground-fault protection module) (Only with ground-fault protection module) Ground-fault alarm (Only with ground-fault protection module) (Only with ground-fault protection module) Auxiliary relay ETU fault General data Setting range of the operating current Ig Increment size when settings are made for the ETU76B using the menu Legend, see page /4. I and size II III From... to Increment size From... to Increment size A 00 A 400 A , B 300 A 600 A C 600 A 800 A max. 000 D 900 A 000 A E 200 A 200 A Siemens LV 0 206/207 /5

16 3WL /Non-Automatic 3-pole, fixed-mounted versions Selection and ordering data Max. rated circuit breaker current I n max. Rated current ) I n Breaking capacity DT I cu 55/66 ka at 500 V, I cu = I cs ECO breaking capacity N Article No. Basic price SET, M) A A ka Horizontal main circuit connection I WL06-2@@32-@@@@ unit CA WL08-2@@32-@@@@ unit CA WL0-2@@32-@@@@ unit CA WL2-2@@32-@@@@ unit CA WL6-2@@32-@@@@ unit CA WL20-2@@32-@@@@ unit CA II WL208-2@@32-@@@@ unit CA WL20-2@@32-@@@@ unit CA WL22-2@@32-@@@@ unit CA WL26-2@@32-@@@@ unit CA WL220-2@@32-@@@@ unit CA WL225-2@@32-@@@@ unit CA WL232-2@@32-@@@@ unit CA Vertical main circuit connection I WL06-2@@3-@@@@ unit CA WL08-2@@3-@@@@ unit CA WL0-2@@3-@@@@ unit CA WL2-2@@3-@@@@ unit CA WL6-2@@3-@@@@ unit CA WL20-2@@3-@@@@ unit CA II WL208-2@@3-@@@@ unit CA WL20-2@@3-@@@@ unit CA WL22-2@@3-@@@@ unit CA WL26-2@@3-@@@@ unit CA WL220-2@@3-@@@@ unit CA WL225-2@@3-@@@@ unit CA WL232-2@@3-@@@@ unit CA WL240-2@@3-@@@@ unit CA N Options Additional price Non-automatic air circuit Without Electronic Trip Units AA None breakers 2) Electronic Trip Units Operating mechanism, auxiliary release, auxiliary switch Versions without ground-fault protection ETU5B: Protection functions LI 6) BB ETU25B: Protection functions LSI CB ETU45B: Protection functions LSIN 3) EB ETU45B: Protection functions LSIN 3) FB with 4-line display ETU76B: Protection functions LSIN 3) with graphics display NB Versions with ground-fault protection ETU27B: Protection functions LSING 4) DG ETU45B: Protection functions LS- EG ING 3)5) ETU45B: Protection functions LSING 3)5) with 4-line display ETU76B: Protection functions LS- ING 3)5) with graphics display Manual operating mechanism with mechanical closing, without st and 2nd auxiliary releases; auxiliary switch 2 NC + 2 NO For further Article No. supplements, see page /44 FG NG AA2 None Additional price ) The rated current is determined by the rating plug. For the standard version, the supplied module is equal to the maximum rated current. If a lower rated current is required, adaptation by order code, see page /45. 2) For permissible rated short-time current I cc and rated short-circuit making capacity I cm for non-automatic air circuit breakers, see page /3. 3) Current transformers for protection of the N-conductor and current transformers for detection of the ground-fault current in the grounded neutral point of the transformer are to be ordered separately, see page /58. 4) Current transformers for protection of the N conductor are to be ordered separately, see page /58. 5) ETU45B and ETU76B with ground-fault protection module GFM AT (alarm and tripping), see page /58. 6) ETU5B cannot be used with 3WL circuit breakers, size III. /6 Siemens LV 0 206/207

17 3WL /Non-Automatic Max. rated circuit breaker current I n max. Rated current ) I n Breaking capacity DT I cu 55/66 ka at 500 V, I cu = I cs ECO breaking capacity N Article No. 3-pole, fixed-mounted versions Basic price SET, M) A A ka Front main circuit connection, single hole I WL06-2@@33-@@@@ unit CA WL08-2@@33-@@@@ unit CA WL0-2@@33-@@@@ unit CA WL2-2@@33-@@@@ unit CA WL6-2@@33-@@@@ unit CA II WL208-2@@33-@@@@ unit CA WL20-2@@33-@@@@ unit CA WL22-2@@33-@@@@ unit CA WL26-2@@33-@@@@ unit CA WL220-2@@33-@@@@ unit CA WL225-2@@33-@@@@ unit CA WL232-2@@33-@@@@ unit CA Front main circuit connection, double hole I WL06-2@@34-@@@@ unit CA WL08-2@@34-@@@@ unit CA WL0-2@@34-@@@@ unit CA WL2-2@@34-@@@@ unit CA WL6-2@@34-@@@@ unit CA WL20-2@@34-@@@@ unit CA II WL208-2@@34-@@@@ unit CA WL20-2@@34-@@@@ unit CA WL22-2@@34-@@@@ unit CA WL26-2@@34-@@@@ unit CA WL220-2@@34-@@@@ unit CA WL225-2@@34-@@@@ unit CA WL232-2@@34-@@@@ unit CA N Options Additional price Non-automatic air circuit Without Electronic Trip Units AA None breakers 2) Electronic Trip Units Operating mechanism, auxiliary release, auxiliary switch Versions without ground-fault protection ETU5B: Protection functions LI 6) BB ETU25B: Protection functions LSI CB ETU45B: Protection functions LSIN 3) EB ETU45B: Protection functions LSIN 3) FB with 4-line display ETU76B: Protection functions LSIN 3) with graphics display NB Versions with ground-fault protection ETU27B: Protection functions LSING 4) DG ETU45B: Protection functions LS- EG ING 3)5) ETU45B: Protection functions LSING 3)5) with 4-line display ETU76B: Protection functions LS- ING 3)5) with graphics display Manual operating mechanism with mechanical closing, without st and 2nd auxiliary releases; auxiliary switch 2 NC + 2 NO For further Article No. supplements, see page /44 FG NG AA2 None Additional price ) The rated current is determined by the rating plug. For the standard version, the supplied module is equal to the maximum rated current. If a lower rated current is required, adaptation by order code, see page /45. 2) For permissible rated short-time current I cc and rated short-circuit making capacity I cm for non-automatic air circuit breakers, see page /3. 3) Current transformers for protection of the N-conductor and current transformers for detection of the ground-fault current in the grounded neutral point of the transformer are to be ordered separately, see page /58. 4) Current transformers for protection of the N conductor are to be ordered separately, see page /58. 5) ETU45B and ETU76B with ground-fault protection module GFM AT (alarm and tripping), see page /58. 6) ETU5B cannot be used with 3WL circuit breakers, size III. Siemens LV 0 206/207 /7

18 3WL /Non-Automatic 3-pole, fixed-mounted versions Max. rated circuit breaker current I n max. Rated current ) I n Breaking capacity DT I cu 66/80 ka at 500 V, I cu = I cs standard breaking capacity S Article No. Basic price SET, M) A A ka Horizontal main circuit connection I WL06-3@@32-@@@@ unit CA WL08-3@@32-@@@@ unit CA WL0-3@@32-@@@@ unit CA WL2-3@@32-@@@@ unit CA WL6-3@@32-@@@@ unit CA WL20-3@@32-@@@@ unit CA II WL208-3@@32-@@@@ unit CA WL20-3@@32-@@@@ unit CA WL22-3@@32-@@@@ unit CA WL26-3@@32-@@@@ unit CA WL220-3@@32-@@@@ unit CA WL225-3@@32-@@@@ unit CA WL232-3@@32-@@@@ unit CA Vertical main circuit connection I WL06-3@@3-@@@@ unit CA WL08-3@@3-@@@@ unit CA WL0-3@@3-@@@@ unit CA WL2-3@@3-@@@@ unit CA WL6-3@@3-@@@@ unit CA WL20-3@@3-@@@@ unit CA II WL208-3@@3-@@@@ unit CA WL20-3@@3-@@@@ unit CA WL22-3@@3-@@@@ unit CA WL26-3@@3-@@@@ unit CA WL220-3@@3-@@@@ unit CA WL225-3@@3-@@@@ unit CA WL232-3@@3-@@@@ unit CA WL240-3@@3-@@@@ unit CA S Options Additional price Non-automatic air circuit Without Electronic Trip Units AA None breakers 2) Electronic Trip Units Operating mechanism, auxiliary release, auxiliary switch Versions without ground-fault protection ETU5B: Protection functions LI 6) BB ETU25B: Protection functions LSI CB ETU45B: Protection functions LSIN 3) EB ETU45B: Protection functions LSIN 3) FB with 4-line display ETU76B: Protection functions LSIN 3) with graphics display NB Versions with ground-fault protection ETU27B: Protection functions LS- DG ING 4) ETU45B: Protection functions LS- EG ING 3)5) ETU45B: Protection functions LSING 3)5) with 4-line display ETU76B: Protection functions LS- ING 3)5) with graphics display Manual operating mechanism with mechanical closing, without st and 2nd auxiliary releases; auxiliary switch 2 NC + 2 NO For further Article No. supplements, see page /44 FG NG AA2 None Additional price ) The rated current is determined by the rating plug. For the standard version, the supplied module is equal to the maximum rated current. If a lower rated current is required, adaptation by order code, see page /45. 2) For permissible rated short-time current I cc and rated short-circuit making capacity I cm for non-automatic air circuit breakers, see page /3. 3) Current transformers for protection of the N-conductor and current transformers for detection of the ground-fault current in the grounded neutral point of the transformer are to be ordered separately, see page /58. 4) Current transformers for protection of the N conductor are to be ordered separately, see page /58. 5) ETU45B and ETU76B with ground-fault protection module GFM AT (alarm and tripping), see page /58. 6) ETU5B cannot be used with 3WL circuit breakers, size III. /8 Siemens LV 0 206/207

19 3WL /Non-Automatic Max. rated circuit breaker current I n max. Rated current ) I n Breaking capacity DT I cu 66/80 ka at 500 V, I cu = I cs standard breaking capacity S Article No. 3-pole, fixed-mounted versions Basic price SET, M) A A ka Front main circuit connection, single hole I WL06-3@@33-@@@@ unit CA WL08-3@@33-@@@@ unit CA WL0-3@@33-@@@@ unit CA WL2-3@@33-@@@@ unit CA WL6-3@@33-@@@@ unit CA II WL208-3@@33-@@@@ unit CA WL20-3@@33-@@@@ unit CA WL22-3@@33-@@@@ unit CA WL26-3@@33-@@@@ unit CA WL220-3@@33-@@@@ unit CA WL225-3@@33-@@@@ unit CA WL232-3@@33-@@@@ unit CA Front main circuit connection, double hole I WL06-3@@34-@@@@ unit CA WL08-3@@34-@@@@ unit CA WL0-3@@34-@@@@ unit CA WL2-3@@34-@@@@ unit CA WL6-3@@34-@@@@ unit CA WL20-3@@34-@@@@ unit CA II WL208-3@@34-@@@@ unit CA WL20-3@@34-@@@@ unit CA WL22-3@@34-@@@@ unit CA WL26-3@@34-@@@@ unit CA WL220-3@@34-@@@@ unit CA WL225-3@@34-@@@@ unit CA WL232-3@@34-@@@@ unit CA S Options Additional price Non-automatic air circuit Without Electronic Trip Units AA None breakers 2) Electronic Trip Units Operating mechanism, auxiliary release, auxiliary switch Versions without ground-fault protection ETU5B: Protection functions LI 6) BB ETU25B: Protection functions LSI CB ETU45B: Protection functions LSIN 3) EB ETU45B: Protection functions LSIN 3) FB with 4-line display ETU76B: Protection functions LSIN 3) with graphics display NB Versions with ground-fault protection ETU27B: Protection functions LS- DG ING 4) ETU45B: Protection functions LS- EG ING 3)5) ETU45B: Protection functions LSING 3)5) with 4-line display ETU76B: Protection functions LS- ING 3)5) with graphics display Manual operating mechanism with mechanical closing, without st and 2nd auxiliary releases; auxiliary switch 2 NC + 2 NO For further Article No. supplements, see page /44 FG NG AA2 None Additional price ) The rated current is determined by the rating plug. For the standard version, the supplied module is equal to the maximum rated current. If a lower rated current is required, adaptation by order code, see page /45. 2) For permissible rated short-time current I cc and rated short-circuit making capacity I cm for non-automatic air circuit breakers, see page /3. 3) Current transformers for protection of the N-conductor and current transformers for detection of the ground-fault current in the grounded neutral point of the transformer are to be ordered separately, see page /58. 4) Current transformers for protection of the N conductor are to be ordered separately, see page /58. 5) ETU45B and ETU76B with ground-fault protection module GFM AT (alarm and tripping), see page /58. 6) ETU5B cannot be used with 3WL circuit breakers, size III. Siemens LV 0 206/207 /9

20 3WL /Non-Automatic 3-pole, fixed-mounted versions Max. rated circuit breaker current I n max. Rated current ) I n Breaking capacity DT I cu 85/00 ka at 500 V, I cu = I cs high breaking capacity H Article No. Basic price SET, M) A A ka Horizontal main circuit connection I WL06-4@@32-@@@@ unit CA WL08-4@@32-@@@@ unit CA WL0-4@@32-@@@@ unit CA WL2-4@@32-@@@@ unit CA WL6-4@@32-@@@@ unit CA WL20-4@@32-@@@@ unit CA II WL208-4@@32-@@@@ unit CA WL20-4@@32-@@@@ unit CA WL22-4@@32-@@@@ unit CA WL26-4@@32-@@@@ unit CA WL220-4@@32-@@@@ unit CA WL225-4@@32-@@@@ unit CA WL232-4@@32-@@@@ unit CA III WL340-4@@32-@@@@ unit CA WL350-4@@32-@@@@ unit CA Vertical main circuit connection I WL06-4@@3-@@@@ unit CA WL08-4@@3-@@@@ unit CA WL0-4@@3-@@@@ unit CA WL2-4@@3-@@@@ unit CA WL6-4@@3-@@@@ unit CA WL20-4@@3-@@@@ unit CA II WL208-4@@3-@@@@ unit CA WL20-4@@3-@@@@ unit CA WL22-4@@3-@@@@ unit CA WL26-4@@3-@@@@ unit CA WL220-4@@3-@@@@ unit CA WL225-4@@3-@@@@ unit CA WL232-4@@3-@@@@ unit CA WL240-4@@3-@@@@ unit CA III WL340-4@@3-@@@@ unit CA WL350-4@@3-@@@@ unit CA WL363-4@@3-@@@@ unit CA H Options Additional price Non-automatic air circuit Without Electronic Trip Units AA None breakers 2) Electronic Trip Units Operating mechanism, auxiliary release, auxiliary switch Versions without ground-fault protection ETU5B: Protection functions LI 6) BB ETU25B: Protection functions LSI CB ETU45B: Protection functions LSIN 3) EB ETU45B: Protection functions LSIN 3) FB with 4-line display ETU76B: Protection functions LSIN 3) with graphics display NB Versions with ground-fault protection ETU27B: Protection functions LSING 4) DG ETU45B: Protection functions LSING 3)5) EG ETU45B: Protection functions LSING 3)5) FG with 4-line display ETU76B: Protection functions LSING 3)5) with graphics display NG Manual operating mechanism with mechanical closing, without st and 2nd auxiliary releases; auxiliary switch 2 NC + 2 NO For further Article No. supplements, see page /44 AA2 None Additional price ) The rated current is determined by the rating plug. For the standard version, the supplied module is equal to the maximum rated current. If a lower rated current is required, adaptation by order code, see page /45. 2) For permissible rated short-time current I cc and rated short-circuit making capacity I cm for non-automatic air circuit breakers, see page /3. /20 Siemens LV 0 206/207 3) Current transformers for protection of the N-conductor and current transformers for detection of the ground-fault current in the grounded neutral point of the transformer are to be ordered separately, see page /58. 4) Current transformers for protection of the N conductor are to be ordered separately, see page /58. 5) ETU45B and ETU76B with ground-fault protection module GFM AT (alarm and tripping), see page /58. 6) ETU5B cannot be used with 3WL circuit breakers, size III.

21 3WL /Non-Automatic Max. rated circuit breaker current I n max. Rated current ) I n Breaking capacity DT I cu 85/00 ka at 500 V, I cu = I cs high breaking capacity H Article No. Basic price 3-pole, fixed-mounted versions SET, M) A A ka Front main circuit connection, single hole II WL208-4@@33-@@@@ unit CA WL20-4@@33-@@@@ unit CA WL22-4@@33-@@@@ unit CA WL26-4@@33-@@@@ unit CA WL220-4@@33-@@@@ unit CA WL225-4@@33-@@@@ unit CA WL232-4@@33-@@@@ unit CA III WL340-4@@33-@@@@ unit CA Front main circuit connection, double hole I WL06-4@@34-@@@@ unit CA WL08-4@@34-@@@@ unit CA WL0-4@@34-@@@@ unit CA WL2-4@@34-@@@@ unit CA WL6-4@@34-@@@@ unit CA WL20-4@@34-@@@@ unit CA II WL208-4@@34-@@@@ unit CA WL20-4@@34-@@@@ unit CA WL22-4@@34-@@@@ unit CA WL26-4@@34-@@@@ unit CA WL220-4@@34-@@@@ unit CA WL225-4@@34-@@@@ unit CA WL232-4@@34-@@@@ unit CA III WL340-4@@34-@@@@ unit CA H Options Additional price Non-automatic air circuit Without Electronic Trip Units AA None breakers 2) Electronic Trip Units Operating mechanism, auxiliary release, auxiliary switch Versions without ground-fault protection ETU5B: Protection functions LI 6) BB ETU25B: Protection functions LSI CB ETU45B: Protection functions LSIN 3) EB ETU45B: Protection functions LSIN 3) FB with 4-line display ETU76B: Protection functions LSIN 3) with graphics display NB Versions with ground-fault protection ETU27B: Protection functions LS- DG ING 4) ETU45B: Protection functions LS- EG ING 3)5) ETU45B: Protection functions LSING 3)5) with 4-line display ETU76B: Protection functions LS- ING 3)5) with graphics display Manual operating mechanism with mechanical closing, without st and 2nd auxiliary releases; auxiliary switch 2 NC + 2 NO For further Article No. supplements, see page /44 FG NG AA2 None Additional price ) The rated current is determined by the rating plug. For the standard version, the supplied module is equal to the maximum rated current. If a lower rated current is required, adaptation by order code, see page /45. 2) For permissible rated short-time current I cc and rated short-circuit making capacity I cm for non-automatic air circuit breakers, see page /3. 3) Current transformers for protection of the N-conductor and current transformers for detection of the ground-fault current in the grounded neutral point of the transformer are to be ordered separately, see page /58. 4) Current transformers for protection of the N conductor are to be ordered separately, see page /58. 5) ETU45B and ETU76B with ground-fault protection module GFM AT (alarm and tripping), see page /58. 6) ETU5B cannot be used with 3WL circuit breakers, size III. Siemens LV 0 206/207 /2

22 3WL /Non-Automatic 3-pole, fixed-mounted versions Max. rated circuit breaker current I n max. Rated current ) I n Breaking capacity DT I cu 30/50 ka at 500 V, I cu = I cs very high breaking capacity C Article No. Basic price SET, M) A A ka Horizontal main circuit connection II WL26-5@@32-@@@@ unit CA WL220-5@@32-@@@@ unit CA WL225-5@@32-@@@@ unit CA WL232-5@@32-@@@@ unit CA III WL340-5@@32-@@@@ unit CA WL350-5@@32-@@@@ unit CA Vertical main circuit connection II WL26-5@@3-@@@@ unit CA WL220-5@@3-@@@@ unit CA WL225-5@@3-@@@@ unit CA WL232-5@@3-@@@@ unit CA III WL340-5@@3-@@@@ unit CA WL350-5@@3-@@@@ unit CA WL363-5@@3-@@@@ unit CA C Options Additional price Non-automatic air circuit Without Electronic Trip Units AA None breakers 2) Electronic Trip Units Operating mechanism, auxiliary release, auxiliary switch Versions without ground-fault protection ETU5B: Protection functions LI 3) BB ETU25B: Protection functions LSI CB ETU45B: Protection functions LSIN 4) EB ETU45B: Protection functions LSIN 4) FB with 4-line display ETU76B: Protection functions LSIN 4) with graphics display NB Versions with ground-fault protection ETU27B: Protection functions LS- DG ING 5) ETU45B: Protection functions LS- EG ING 4)6) ETU45B: Protection functions LSING 4)6) with 4-line display ETU76B: Protection functions LS- ING 4)6) with graphics display Manual operating mechanism with mechanical closing, without st and 2nd auxiliary releases; auxiliary switch 2 NC + 2 NO For further Article No. supplements, see page /44 FG NG AA2 None Additional price ) The rated current is determined by the rating plug. For the standard version, the supplied module is equal to the maximum rated current. If a lower rated current is required, adaptation by order code, see page /45. 2) For permissible rated short-time current I cc and rated short-circuit making capacity I cm for non-automatic air circuit breakers, see page /3. 3) ETU5B cannot be used with 3WL circuit breakers, size III. 4) Current transformers for protection of the N-conductor and current transformers for detection of the ground-fault current in the grounded neutral point of the transformer are to be ordered separately, see page /58. 5) Current transformers for protection of the N conductor are to be ordered separately, see page /58. 6) ETU45B and ETU76B with ground-fault protection module GFM AT (alarm and tripping), see page /58. /22 Siemens LV 0 206/207

23 3WL /Non-Automatic Selection and ordering data Max. rated circuit breaker current I n max. Rated current ) I n Breaking capacity DT I cu 55/66 ka at 500 V, I cu = I cs ECO breaking capacity N Article No. Basic price 3-pole, withdrawable versions SET, M) A A ka Without guide frames 2) (for guide frames, see pages /52 to /57) I WL06-2@@35-@@@@ unit CA WL08-2@@35-@@@@ unit CA WL0-2@@35-@@@@ unit CA WL2-2@@35-@@@@ unit CA WL6-2@@35-@@@@ unit CA WL20-2@@35-@@@@ unit CA II WL208-2@@35-@@@@ unit CA WL20-2@@35-@@@@ unit CA WL22-2@@35-@@@@ unit CA WL26-2@@35-@@@@ unit CA WL220-2@@35-@@@@ unit CA WL225-2@@35-@@@@ unit CA WL232-2@@35-@@@@ unit CA WL240-2@@35-@@@@ unit CA With guide frames, horizontal main circuit connection I WL06-2@@36-@@@@ unit CA WL08-2@@36-@@@@ unit CA WL0-2@@36-@@@@ unit CA WL2-2@@36-@@@@ unit CA WL6-2@@36-@@@@ unit CA WL20-2@@36-@@@@ unit CA II WL208-2@@36-@@@@ unit CA WL20-2@@36-@@@@ unit CA WL22-2@@36-@@@@ unit CA WL26-2@@36-@@@@ unit CA WL220-2@@36-@@@@ unit CA WL225-2@@36-@@@@ unit CA WL232-2@@36-@@@@ unit CA N Options Additional price Non-automatic air circuit Without Electronic Trip Units AA None breakers 3) Electronic Trip Units Operating mechanism, auxiliary release, auxiliary switch Versions without ground-fault protection ETU5B: Protection functions LI BB ETU25B: Protection functions LSI CB ETU45B: Protection functions LSIN 4) EB ETU45B: Protection functions LSIN 4) FB with 4-line display ETU76B: Protection functions LSIN 4) with graphics display NB Versions with ground-fault protection ETU27B: Protection functions LSING 5) DG ETU45B: Protection functions LSING 4)6) EG ETU45B: Protection functions LSING 4)6) FG with 4-line display ETU76B: Protection functions LSING 4)6) with graphics display NG Manual operating mechanism with mechanical closing, without st and 2nd auxiliary releases; auxiliary switch 2 NC + 2 NO For further Article No. supplements, see page /44 AA2 None Additional price ) The rated current is determined by the rating plug. For the standard version, the supplied module is equal to the maximum rated current. If a lower rated current is required, adaptation by order code, see page /45. 2) Z options which are installed on the guide frame are not available. 3) For permissible rated short-time current I cc and rated short-circuit making capacity I cm for non-automatic air circuit breakers, see page /3. 4) Current transformers for protection of the N-conductor and current transformers for detection of the ground-fault current in the grounded neutral point of the transformer are to be ordered separately, see page /58. 5) Current transformers for protection of the N conductor are to be ordered separately, see page /58. 6) ETU45B to ETU76B with ground-fault protection module GFM AT (alarm and tripping), see page /58. Siemens LV 0 206/207 /23

24 3WL /Non-Automatic 3-pole, withdrawable versions Max. rated circuit breaker current I n max. Rated current ) I n Breaking capacity DT I cu 55/66 ka at 500 V, I cu = I cs ECO breaking capacity N Article No. Basic price SET, M) A A ka With guide frames, vertical main circuit connection I WL06-2@@37-@@@@ unit CA WL08-2@@37-@@@@ unit CA WL0-2@@37-@@@@ unit CA WL2-2@@37-@@@@ unit CA WL6-2@@37-@@@@ unit CA WL20-2@@37-@@@@ unit CA II WL208-2@@37-@@@@ unit CA WL20-2@@37-@@@@ unit CA WL22-2@@37-@@@@ unit CA WL26-2@@37-@@@@ unit CA WL220-2@@37-@@@@ unit CA WL225-2@@37-@@@@ unit CA WL232-2@@37-@@@@ unit CA WL240-2@@37-@@@@ unit CA With guide frames, connecting flanges I WL06-2@@38-@@@@ unit CA WL08-2@@38-@@@@ unit CA WL0-2@@38-@@@@ unit CA WL2-2@@38-@@@@ unit CA WL6-2@@38-@@@@ unit CA WL20-2@@38-@@@@ unit CA II WL208-2@@38-@@@@ unit CA WL20-2@@38-@@@@ unit CA WL22-2@@38-@@@@ unit CA WL26-2@@38-@@@@ unit CA WL220-2@@38-@@@@ unit CA WL225-2@@38-@@@@ unit CA WL232-2@@38-@@@@ unit CA N Options Additional price Non-automatic air circuit Without Electronic Trip Units AA None breakers 3) Electronic Trip Units Operating mechanism, auxiliary release, auxiliary switch Versions without ground-fault protection ETU5B: Protection functions LI BB ETU25B: Protection functions LSI CB ETU45B: Protection functions LSIN 4) EB ETU45B: Protection functions LSIN 4) FB with 4-line display ETU76B: Protection functions LSIN 4) with graphics display NB Versions with ground-fault protection ETU27B: Protection functions LS- DG ING 5) ETU45B: Protection functions LS- EG ING 4)6) ETU45B: Protection functions LSING 4)6) with 4-line display ETU76B: Protection functions LS- ING 4)6) with graphics display Manual operating mechanism with mechanical closing, without st and 2nd auxiliary releases; auxiliary switch 2 NC + 2 NO For further Article No. supplements, see page /44 FG NG AA2 None Additional price ) The rated current is determined by the rating plug. For the standard version, the supplied module is equal to the maximum rated current. If a lower rated current is required, adaptation by order code, see page /45. 2) Z options which are installed on the guide frame are not available. 3) For permissible rated short-time current I cc and rated short-circuit making capacity I cm for non-automatic air circuit breakers, see page /3. 4) Current transformers for protection of the N-conductor and current transformers for detection of the ground-fault current in the grounded neutral point of the transformer are to be ordered separately, see page /58. 5) Current transformers for protection of the N conductor are to be ordered separately, see page /58. 6) ETU45B to ETU76B with ground-fault protection module GFM AT (alarm and tripping), see page /58. /24 Siemens LV 0 206/207

25 3WL /Non-Automatic Max. rated circuit breaker current I n max. Rated current ) I n Breaking capacity DT I cu 66/80 ka at 500 V, I cu = I cs standard breaking capacity S Article No. Basic price 3-pole, withdrawable versions SET, M) A A ka Without guide frames 2) (for guide frames, see pages /52 to /57) I WL06-3@@35-@@@@ unit CA WL08-3@@35-@@@@ unit CA WL0-3@@35-@@@@ unit CA WL2-3@@35-@@@@ unit CA WL6-3@@35-@@@@ unit CA WL20-3@@35-@@@@ unit CA II WL208-3@@35-@@@@ unit CA WL20-3@@35-@@@@ unit CA WL22-3@@35-@@@@ unit CA WL26-3@@35-@@@@ unit CA WL220-3@@35-@@@@ unit CA WL225-3@@35-@@@@ unit CA WL232-3@@35-@@@@ unit CA WL240-3@@35-@@@@ unit With guide frames, horizontal main circuit connection I WL06-3@@36-@@@@ unit CA WL08-3@@36-@@@@ unit CA WL0-3@@36-@@@@ unit CA WL2-3@@36-@@@@ unit CA WL6-3@@36-@@@@ unit CA WL20-3@@36-@@@@ unit CA II WL208-3@@36-@@@@ unit CA WL20-3@@36-@@@@ unit CA WL22-3@@36-@@@@ unit CA WL26-3@@36-@@@@ unit CA WL220-3@@36-@@@@ unit CA WL225-3@@36-@@@@ unit CA WL232-3@@36-@@@@ unit CA S Options Additional price Non-automatic air circuit Without Electronic Trip Units AA None breakers 3) Electronic Trip Units Operating mechanism, auxiliary release, auxiliary switch Versions without ground-fault protection ETU5B: Protection functions LI BB ETU25B: Protection functions LSI CB ETU45B: Protection functions LSIN 4) EB ETU45B: Protection functions LSIN 4) FB with 4-line display ETU76B: Protection functions LSIN 4) with graphics display NB Versions with ground-fault protection ETU27B: Protection functions LS- DG ING 5) ETU45B: Protection functions LS- EG ING 4)6) ETU45B: Protection functions LSING 4)6) with 4-line display ETU76B: Protection functions LS- ING 4)6) with graphics display Manual operating mechanism with mechanical closing, without st and 2nd auxiliary releases; auxiliary switch 2 NC + 2 NO For further Article No. supplements, see page /44 FG NG AA2 None Additional price ) The rated current is determined by the rating plug. For the standard version, the supplied module is equal to the maximum rated current. If a lower rated current is required, adaptation by order code, see page /45. 2) Z options which are installed on the guide frame are not available. 3) For permissible rated short-time current I cc and rated short-circuit making capacity I cm for non-automatic air circuit breakers, see page /3. 4) Current transformers for protection of the N-conductor and current transformers for detection of the ground-fault current in the grounded neutral point of the transformer are to be ordered separately, see page /58. 5) Current transformers for protection of the N conductor are to be ordered separately, see page /58. 6) ETU45B to ETU76B with ground-fault protection module GFM AT (alarm and tripping), see page /58. Siemens LV 0 206/207 /25

26 3WL /Non-Automatic 3-pole, withdrawable versions Max. rated circuit breaker current I n max. Rated current ) I n Breaking capacity DT I cu 66/80 ka at 500 V, I cu = I cs standard breaking capacity S Article No. Basic price SET, M) A A ka With guide frames, vertical main circuit connection I WL06-3@@37-@@@@ unit CA WL08-3@@37-@@@@ unit CA WL0-3@@37-@@@@ unit CA WL2-3@@37-@@@@ unit CA WL6-3@@37-@@@@ unit CA WL20-3@@37-@@@@ unit CA II WL208-3@@37-@@@@ unit CA WL20-3@@37-@@@@ unit CA WL22-3@@37-@@@@ unit CA WL26-3@@37-@@@@ unit CA WL220-3@@37-@@@@ unit CA WL225-3@@37-@@@@ unit CA WL232-3@@37-@@@@ unit CA WL240-3@@37-@@@@ unit CA With guide frames, connecting flanges I WL06-3@@38-@@@@ unit CA WL08-3@@38-@@@@ unit CA WL0-3@@38-@@@@ unit CA WL2-3@@38-@@@@ unit CA WL6-3@@38-@@@@ unit CA WL20-3@@38-@@@@ unit CA II WL208-3@@38-@@@@ unit CA WL20-3@@38-@@@@ unit CA WL22-3@@38-@@@@ unit CA WL26-3@@38-@@@@ unit CA WL220-3@@38-@@@@ unit CA WL225-3@@38-@@@@ unit CA WL232-3@@38-@@@@ unit CA S Options Additional price Non-automatic air circuit Without Electronic Trip Units AA None breakers 3) Electronic Trip Units Operating mechanism, auxiliary release, auxiliary switch Versions without ground-fault protection ETU5B: Protection functions LI BB ETU25B: Protection functions LSI CB ETU45B: Protection functions LSIN 4) EB ETU45B: Protection functions LSIN 4) FB with 4-line display ETU76B: Protection functions LSIN 4) with graphics display NB Versions with ground-fault protection ETU27B: Protection functions LS- DG ING 5) ETU45B: Protection functions LS- EG ING 4)6) ETU45B: Protection functions LSING 4)6) with 4-line display ETU76B: Protection functions LS- ING 4)6) with graphics display Manual operating mechanism with mechanical closing, without st and 2nd auxiliary releases; auxiliary switch 2 NC + 2 NO For further Article No. supplements, see page /44 FG NG AA2 None Additional price ) The rated current is determined by the rating plug. For the standard version, the supplied module is equal to the maximum rated current. If a lower rated current is required, adaptation by order code, see page /45. 2) Z options which are installed on the guide frame are not available. 3) For permissible rated short-time current I cc and rated short-circuit making capacity I cm for non-automatic air circuit breakers, see page /3. 4) Current transformers for protection of the N-conductor and current transformers for detection of the ground-fault current in the grounded neutral point of the transformer are to be ordered separately, see page /58. 5) Current transformers for protection of the N conductor are to be ordered separately, see page /58. 6) ETU45B to ETU76B with ground-fault protection module GFM AT (alarm and tripping), see page /58. /26 Siemens LV 0 206/207

27 3WL /Non-Automatic Max. rated circuit breaker current I n max. Rated current ) I n Breaking capacity DT I cu 85/00 ka at 500 V, I cu = I cs high breaking capacity H Article No. Basic price 3-pole, withdrawable versions SET, M) A A ka Without guide frames 2) (for guide frames, see pages /52 to /57) I WL06-4@@35-@@@@ unit CA WL08-4@@35-@@@@ unit CA WL0-4@@35-@@@@ unit CA WL2-4@@35-@@@@ unit CA WL6-4@@35-@@@@ unit CA WL20-4@@35-@@@@ unit CA II WL208-4@@35-@@@@ unit CA WL20-4@@35-@@@@ unit CA WL22-4@@35-@@@@ unit CA WL26-4@@35-@@@@ unit CA WL220-4@@35-@@@@ unit CA WL225-4@@35-@@@@ unit CA WL232-4@@35-@@@@ unit CA WL240-4@@35-@@@@ unit CA III WL340-4@@35-@@@@ unit CA WL350-4@@35-@@@@ unit CA WL363-4@@35-@@@@ unit CA With guide frames, horizontal main circuit connection I WL06-4@@36-@@@@ unit CA WL08-4@@36-@@@@ unit CA WL0-4@@36-@@@@ unit CA WL2-4@@36-@@@@ unit CA WL6-4@@36-@@@@ unit CA WL20-4@@36-@@@@ unit CA II WL208-4@@36-@@@@ unit CA WL20-4@@36-@@@@ unit CA WL22-4@@36-@@@@ unit CA WL26-4@@36-@@@@ unit CA WL220-4@@36-@@@@ unit CA WL225-4@@36-@@@@ unit CA WL232-4@@36-@@@@ unit CA III WL340-4@@36-@@@@ unit CA WL350-4@@36-@@@@ unit CA H Options Additional price ) The rated current is determined by the rating plug. For the standard version, the supplied module is equal to the maximum rated current. If a lower rated current is required, adaptation by order code, see page /45. 2) Z options which are installed on the guide frame are not available. 3) For permissible rated short-time current I cc and rated short-circuit making capacity I cm for non-automatic air circuit breakers, see page /3. Additional price Non-automatic air circuit Without Electronic Trip Units AA None breakers 3) Electronic Trip Units Operating mechanism, auxiliary release, auxiliary switch Versions without ground-fault protection ETU5B: Protection functions LI 7) BB ETU25B: Protection functions LSI CB ETU45B: Protection functions LSIN 4) EB ETU45B: Protection functions LSIN 4) FB with 4-line display ETU76B: Protection functions LSIN 4) with graphics display NB Versions with ground-fault protection ETU27B: Protection functions LSING 5) DG ETU45B: Protection functions LSING 4)6) EG ETU45B: Protection functions LSING 4)6) FG with 4-line display ETU76B: Protection functions LSING 4)6) with graphics display NG Manual operating mechanism with mechanical closing, without st and 2nd auxiliary releases; auxiliary switch 2 NC + 2 NO For further Article No. supplements, see page /44 AA2 None 4) Current transformers for protection of the N-conductor and current transformers for detection of the ground-fault current in the grounded neutral point of the transformer are to be ordered separately, see page /58. 5) Current transformers for protection of the N conductor are to be ordered separately, see page /58. 6) ETU45B to ETU76B with ground-fault protection module GFM AT (alarm and tripping), see page /58. 7) ETU5B cannot be used with 3WL circuit breakers, size III. Siemens LV 0 206/207 /27

28 3WL /Non-Automatic 3-pole, withdrawable versions Max. rated circuit breaker current I n max. Rated current ) I n Breaking capacity DT I cu 85/00 ka at 500 V, I cu = I cs high breaking capacity H Article No. Basic price SET, M) A A ka With guide frames, vertical main circuit connection I WL06-4@@37-@@@@ unit CA WL08-4@@37-@@@@ unit CA WL0-4@@37-@@@@ unit CA WL2-4@@37-@@@@ unit CA WL6-4@@37-@@@@ unit CA WL20-4@@37-@@@@ unit CA II WL208-4@@37-@@@@ unit CA WL20-4@@37-@@@@ unit CA WL22-4@@37-@@@@ unit CA WL26-4@@37-@@@@ unit CA WL220-4@@37-@@@@ unit CA WL225-4@@37-@@@@ unit CA WL232-4@@37-@@@@ unit CA WL240-4@@37-@@@@ unit CA III WL340-4@@37-@@@@ unit CA WL350-4@@37-@@@@ unit CA WL363-4@@37-@@@@ unit CA With guide frames, connecting flanges I WL06-4@@38-@@@@ unit CA WL08-4@@38-@@@@ unit CA WL0-4@@38-@@@@ unit CA WL2-4@@38-@@@@ unit CA WL6-4@@38-@@@@ unit CA WL20-4@@38-@@@@ unit CA II WL208-4@@38-@@@@ unit CA WL20-4@@38-@@@@ unit CA WL22-4@@38-@@@@ unit CA WL26-4@@38-@@@@ unit CA WL220-4@@38-@@@@ unit CA WL225-4@@38-@@@@ unit CA WL232-4@@38-@@@@ unit CA III WL340-4@@38-@@@@ unit CA H Options Additional price Non-automatic air circuit Without Electronic Trip Units AA None breakers 3) Electronic Trip Units Operating mechanism, auxiliary release, auxiliary switch Versions without ground-fault protection ETU5B: Protection functions LI 7) BB ETU25B: Protection functions LSI CB ETU45B: Protection functions LSIN 4) EB ETU45B: Protection functions LSIN 4) FB with 4-line display ETU76B: Protection functions LSIN 4) with graphics display NB Versions with ground-fault protection ETU27B: Protection functions LSING 5) DG ETU45B: Protection functions LSING 4)6) EG ETU45B: Protection functions LSING 4)6) FG with 4-line display ETU76B: Protection functions LSING 4)6) with graphics display NG Manual operating mechanism with mechanical closing, without st and 2nd auxiliary releases; auxiliary switch 2 NC + 2 NO For further Article No. supplements, see page /44 AA2 None Additional price ) The rated current is determined by the rating plug. For the standard version, the supplied module is equal to the maximum rated current. If a lower rated current is required, adaptation by order code, see page /45. 2) Z options which are installed on the guide frame are not available. 3) For permissible rated short-time current I cc and rated short-circuit making capacity I cm for non-automatic air circuit breakers, see page /3. 4) Current transformers for protection of the N-conductor and current transformers for detection of the ground-fault current in the grounded neutral point of the transformer are to be ordered separately, see page /58. 5) Current transformers for protection of the N conductor are to be ordered separately, see page /58. 6) ETU45B to ETU76B with ground-fault protection module GFM AT (alarm and tripping), see page /58. 7) ETU5B cannot be used with 3WL circuit breakers, size III. /28 Siemens LV 0 206/207

29 3WL /Non-Automatic Max. rated circuit breaker current I n max. Rated current ) I n Breaking capacity DT I cu 30/50 ka at 500 V, I cu = I cs very high breaking capacity C Article No. 3-pole, withdrawable versions Basic price SET, M) A A ka Without guide frames 2) (for guide frames, see pages /52 to /57) II WL26-5@@35-@@@@ unit CA WL220-5@@35-@@@@ unit CA WL225-5@@35-@@@@ unit CA WL232-5@@35-@@@@ unit CA III WL340-5@@35-@@@@ unit CA WL350-5@@35-@@@@ unit CA WL363-5@@35-@@@@ unit CA With guide frames, horizontal main circuit connection II WL26-5@@36-@@@@ unit CA WL220-5@@36-@@@@ unit CA WL225-5@@36-@@@@ unit CA WL232-5@@36-@@@@ unit CA III WL340-5@@36-@@@@ unit CA WL350-5@@36-@@@@ unit CA With guide frames, vertical main circuit connection II WL26-5@@37-@@@@ unit CA WL220-5@@37-@@@@ unit CA WL225-5@@37-@@@@ unit CA WL232-5@@37-@@@@ unit CA III WL340-5@@37-@@@@ unit CA WL350-5@@37-@@@@ unit CA WL363-5@@37-@@@@ unit CA C Options Additional price Non-automatic air circuit Without Electronic Trip Units AA None breakers 3) Electronic Trip Units Operating mechanism, auxiliary release, auxiliary switch Versions without ground-fault protection ETU5B: Protection functions LI 4) BB ETU25B: Protection functions LSI CB ETU45B: Protection functions LSIN 5) EB ETU45B: Protection functions LSIN 5) FB with 4-line display ETU76B: Protection functions LSIN 5) with graphics display NB Versions with ground-fault protection ETU27B: Protection functions LS- DG ING 6) ETU45B: Protection functions LS- EG ING 5)7) ETU45B: Protection functions LSING 5)7) with 4-line display ETU76B: Protection functions LS- ING 5)7) with graphics display Manual operating mechanism with mechanical closing, without st and 2nd auxiliary releases; auxiliary switch 2 NC + 2 NO For further Article No. supplements, see page /44 FG NG AA2 None Additional price ) The rated current is determined by the rating plug. For the standard version, the supplied module is equal to the maximum rated current. If a lower rated current is required, adaptation by order code, see page /45. 2) Z options which are installed on the guide frame are not available. 3) For permissible rated short-time current I cc and rated short-circuit making capacity I cm for non-automatic air circuit breakers, see page /3. 4) ETU5B cannot be used with 3WL circuit breakers, size III. 5) Current transformers for protection of the N-conductor and current transformers for detection of the ground-fault current in the grounded neutral point of the transformer are to be ordered separately, see page /58. 6) Current transformers for protection of the N conductor are to be ordered separately, see page /58. 7) ETU45B to ETU76B with ground-fault protection module GFM AT (alarm and tripping), see page /58. Siemens LV 0 206/207 /29

30 3WL /Non-Automatic 4-pole, fixed-mounted versions Selection and ordering data Max. rated circuit breaker current I n max. Rated current ) I n Breaking capacity DT I cu 55/66 ka at 500 V, I cu = I cs ECO breaking capacity N Article No. Basic price SET, M) A A ka Horizontal main circuit connection I WL06-2@@42-@@@@ unit CA WL08-2@@42-@@@@ unit CA WL0-2@@42-@@@@ unit CA WL2-2@@42-@@@@ unit CA WL6-2@@42-@@@@ unit CA WL20-2@@42-@@@@ unit CA II WL208-2@@42-@@@@ unit CA WL20-2@@42-@@@@ unit CA WL22-2@@42-@@@@ unit CA WL26-2@@42-@@@@ unit CA WL220-2@@42-@@@@ unit CA WL225-2@@42-@@@@ unit CA WL232-2@@42-@@@@ unit CA Vertical main circuit connection I WL06-2@@4-@@@@ unit CA WL08-2@@4-@@@@ unit CA WL0-2@@4-@@@@ unit CA WL2-2@@4-@@@@ unit CA WL6-2@@4-@@@@ unit CA WL20-2@@4-@@@@ unit CA II WL208-2@@4-@@@@ unit CA WL20-2@@4-@@@@ unit CA WL22-2@@4-@@@@ unit CA WL26-2@@4-@@@@ unit CA WL220-2@@4-@@@@ unit CA WL225-2@@4-@@@@ unit CA WL232-2@@4-@@@@ unit CA WL240-2@@4-@@@@ unit CA N Options Additional price Non-automatic air circuit Without Electronic Trip Units AA None breakers 2) Electronic Trip Units Operating mechanism, auxiliary release, auxiliary switch Versions without ground-fault protection ETU5B: Protection functions LI BB ETU25B: Protection functions LSI CB ETU45B: Protection functions LSIN 3) EB ETU45B: Protection functions LSIN 3) FB with 4-line display ETU76B: Protection functions LSIN 3) with graphics display NB Versions with ground-fault protection ETU27B: Protection functions LS- DG ING 3) ETU45B: Protection functions LS- EG ING 3)4) ETU45B: Protection functions LSING 3)4) with 4-line display ETU76B: Protection functions LS- ING 3)4) with graphics display Manual operating mechanism with mechanical closing, without st and 2nd auxiliary releases; auxiliary switch 2 NC + 2 NO For further Article No. supplements, see page /44 FG NG AA2 None Additional price ) The rated current is determined by the rating plug. For the standard version, the supplied module is equal to the maximum rated current. If a lower rated current is required, adaptation by order code, see page /45. 2) For permissible rated short-time current I cc and rated short-circuit making capacity I cm for non-automatic air circuit breakers, see page /3. 3) Current transformers for protection of the N-conductor and current transformers for detection of the ground-fault current in the grounded neutral point of the transformer are to be ordered separately, see page /58. The internal current transformers for N-conductors can be ordered by adding the supplement " Z" and the order code "F23", see page /47. 4) ETU45B to ETU76B with ground-fault protection module GFM AT (alarm and tripping), see page /58. /30 Siemens LV 0 206/207

31 3WL /Non-Automatic Max. rated circuit breaker current I n max. Rated current ) I n Breaking capacity DT I cu 55/66 ka at 500 V, I cu = I cs ECO breaking capacity N Article No. 4-pole, fixed-mounted versions Basic price SET, M) A A ka Front main circuit connection, single hole I WL06-2@@43-@@@@ unit CA WL08-2@@43-@@@@ unit CA WL0-2@@43-@@@@ unit CA WL2-2@@43-@@@@ unit CA WL6-2@@43-@@@@ unit CA II WL208-2@@43-@@@@ unit CA WL20-2@@43-@@@@ unit CA WL22-2@@43-@@@@ unit CA WL26-2@@43-@@@@ unit CA WL220-2@@43-@@@@ unit CA WL225-2@@43-@@@@ unit CA WL232-2@@43-@@@@ unit CA Front main circuit connection, double hole I WL06-2@@44-@@@@ unit CA WL08-2@@44-@@@@ unit CA WL0-2@@44-@@@@ unit CA WL2-2@@44-@@@@ unit CA WL6-2@@44-@@@@ unit CA WL20-2@@44-@@@@ unit CA II WL208-2@@44-@@@@ unit CA WL20-2@@44-@@@@ unit CA WL22-2@@44-@@@@ unit CA WL26-2@@44-@@@@ unit CA WL220-2@@44-@@@@ unit CA WL225-2@@44-@@@@ unit CA WL232-2@@44-@@@@ unit CA N Options Additional price Non-automatic air circuit Without Electronic Trip Units AA None breakers 2) Electronic Trip Units Operating mechanism, auxiliary release, auxiliary switch Versions without ground-fault protection ETU5B: Protection functions LI BB ETU25B: Protection functions LSI CB ETU45B: Protection functions LSIN 3) EB ETU45B: Protection functions LSIN 3) FB with 4-line display ETU76B: Protection functions LSIN 3) with graphics display NB Versions with ground-fault protection ETU27B: Protection functions LS- DG ING 3) ETU45B: Protection functions LS- EG ING 3)4) ETU45B: Protection functions LSING 3)4) with 4-line display ETU76B: Protection functions LS- ING 3)4) with graphics display Manual operating mechanism with mechanical closing, without st and 2nd auxiliary releases; auxiliary switch 2 NC + 2 NO For further Article No. supplements, see page /44 FG NG AA2 None Additional price ) The rated current is determined by the rating plug. For the standard version, the supplied module is equal to the maximum rated current. If a lower rated current is required, adaptation by order code, see page /45. 2) For permissible rated short-time current I cc and rated short-circuit making capacity I cm for non-automatic air circuit breakers, see page /3. 3) Current transformers for protection of the N-conductor and current transformers for detection of the ground-fault current in the grounded neutral point of the transformer are to be ordered separately, see page /58. The internal current transformers for N-conductors can be ordered by adding the supplement " Z" and the order code "F23", see page /47. 4) ETU45B to ETU76B with ground-fault protection module GFM AT (alarm and tripping), see page /58. Siemens LV 0 206/207 /3

32 3WL /Non-Automatic 4-pole, fixed-mounted versions Max. rated circuit breaker current I n max. Rated current ) I n Breaking capacity DT I cu 66/80 ka at 500 V, I cu = I cs standard breaking capacity S Article No. Basic price SET, M) A A ka Horizontal main circuit connection I WL06-3@@42-@@@@ unit CA WL08-3@@42-@@@@ unit CA WL0-3@@42-@@@@ unit CA WL2-3@@42-@@@@ unit CA WL6-3@@42-@@@@ unit CA WL20-3@@42-@@@@ unit CA II WL208-3@@42-@@@@ unit CA WL20-3@@42-@@@@ unit CA WL22-3@@42-@@@@ unit CA WL26-3@@42-@@@@ unit CA WL220-3@@42-@@@@ unit CA WL225-3@@42-@@@@ unit CA WL232-3@@42-@@@@ unit CA Vertical main circuit connection I WL06-3@@4-@@@@ unit CA WL08-3@@4-@@@@ unit CA WL0-3@@4-@@@@ unit CA WL2-3@@4-@@@@ unit CA WL6-3@@4-@@@@ unit CA WL20-3@@4-@@@@ unit CA II WL208-3@@4-@@@@ unit CA WL20-3@@4-@@@@ unit CA WL22-3@@4-@@@@ unit CA WL26-3@@4-@@@@ unit CA WL220-3@@4-@@@@ unit CA WL225-3@@4-@@@@ unit CA WL232-3@@4-@@@@ unit CA WL240-3@@4-@@@@ unit CA S Options Additional price Non-automatic air circuit Without Electronic Trip Units AA None breakers 2) Electronic Trip Units Operating mechanism, auxiliary release, auxiliary switch Versions without ground-fault protection ETU5B: Protection functions LI BB ETU25B: Protection functions LSI CB ETU45B: Protection functions LSIN 3) EB ETU45B: Protection functions LSIN 3) FB with 4-line display ETU76B: Protection functions LSIN 3) with graphics display NB Versions with ground-fault protection ETU27B: Protection functions LS- DG ING 3) ETU45B: Protection functions LS- EG ING 3)4) ETU45B: Protection functions LSING 3)4) with 4-line display ETU76B: Protection functions LS- ING 3)4) with graphics display Manual operating mechanism with mechanical closing, without st and 2nd auxiliary releases; auxiliary switch 2 NC + 2 NO For further Article No. supplements, see page /44 FG NG AA2 None Additional price ) The rated current is determined by the rating plug. For the standard version, the supplied module is equal to the maximum rated current. If a lower rated current is required, adaptation by order code, see page /45. 2) For permissible rated short-time current I cc and rated short-circuit making capacity I cm for non-automatic air circuit breakers, see page /3. 3) Current transformers for protection of the N-conductor and current transformers for detection of the ground-fault current in the grounded neutral point of the transformer are to be ordered separately, see page /58. The internal current transformers for N-conductors can be ordered by adding the supplement " Z" and the order code "F23", see page /47. 4) ETU45B to ETU76B with ground-fault protection module GFM AT (alarm and tripping), see page /58. /32 Siemens LV 0 206/207

33 3WL /Non-Automatic Max. rated circuit breaker current I n max. Rated current ) I n Breaking capacity DT I cu 66/80 ka at 500 V, I cu = I cs standard breaking capacity S Article No. 4-pole, fixed-mounted versions Basic price SET, M) A A ka Front main circuit connection, single hole I WL06-3@@43-@@@@ unit CA WL08-3@@43-@@@@ unit CA WL0-3@@43-@@@@ unit CA WL2-3@@43-@@@@ unit CA WL6-3@@43-@@@@ unit CA II WL208-3@@43-@@@@ unit CA WL20-3@@43-@@@@ unit CA WL22-3@@43-@@@@ unit CA WL26-3@@43-@@@@ unit CA WL220-3@@43-@@@@ unit CA WL225-3@@43-@@@@ unit CA WL232-3@@43-@@@@ unit CA Front main circuit connection, double hole I WL06-3@@44-@@@@ unit CA WL08-3@@44-@@@@ unit CA WL0-3@@44-@@@@ unit CA WL2-3@@44-@@@@ unit CA WL6-3@@44-@@@@ unit CA WL20-3@@44-@@@@ unit CA II WL208-3@@44-@@@@ unit CA WL20-3@@44-@@@@ unit CA WL22-3@@44-@@@@ unit CA WL26-3@@44-@@@@ unit CA WL220-3@@44-@@@@ unit CA WL225-3@@44-@@@@ unit CA WL232-3@@44-@@@@ unit CA S Options Additional price Non-automatic air circuit Without Electronic Trip Units AA None breakers 2) Electronic Trip Units Operating mechanism, auxiliary release, auxiliary switch Versions without ground-fault protection ETU5B: Protection functions LI BB ETU25B: Protection functions LSI CB ETU45B: Protection functions LSIN 3) EB ETU45B: Protection functions LSIN 3) FB with 4-line display ETU76B: Protection functions LSIN 3) with graphics display NB Versions with ground-fault protection ETU27B: Protection functions LS- DG ING 3) ETU45B: Protection functions LS- EG ING 3)4) ETU45B: Protection functions LSING 3)4) with 4-line display ETU76B: Protection functions LS- ING 3)4) with graphics display Manual operating mechanism with mechanical closing, without st and 2nd auxiliary releases; auxiliary switch 2 NC + 2 NO For further Article No. supplements, see page /44 FG NG AA2 None Additional price ) The rated current is determined by the rating plug. For the standard version, the supplied module is equal to the maximum rated current. If a lower rated current is required, adaptation by order code, see page /45. 2) For permissible rated short-time current I cc and rated short-circuit making capacity I cm for non-automatic air circuit breakers, see page /3. 3) Current transformers for protection of the N-conductor and current transformers for detection of the ground-fault current in the grounded neutral point of the transformer are to be ordered separately, see page /58. The internal current transformers for N-conductors can be ordered by adding the supplement " Z" and the order code "F23", see page /47. 4) ETU45B to ETU76B with ground-fault protection module GFM AT (alarm and tripping), see page /58. Siemens LV 0 206/207 /33

34 3WL /Non-Automatic 4-pole, fixed-mounted versions Max. rated circuit breaker current I n max. Rated current ) I n Breaking capacity DT I cu 85/00 ka at 500 V, I cu = I cs high breaking capacity H Article No. Basic price SET, M) A A ka Horizontal main circuit connection I WL06-4@@42-@@@@ unit CA WL08-4@@42-@@@@ unit CA WL0-4@@42-@@@@ unit CA WL2-4@@42-@@@@ unit CA WL6-4@@42-@@@@ unit CA WL20-4@@42-@@@@ unit CA II WL208-4@@42-@@@@ unit CA WL20-4@@42-@@@@ unit CA WL22-4@@42-@@@@ unit CA WL26-4@@42-@@@@ unit CA WL220-4@@42-@@@@ unit CA WL225-4@@42-@@@@ unit CA WL232-4@@42-@@@@ unit CA III WL340-4@@42-@@@@ unit CA WL350-4@@42-@@@@ unit CA Vertical main circuit connection I WL06-4@@4-@@@@ unit CA WL08-4@@4-@@@@ unit CA WL0-4@@4-@@@@ unit CA WL2-4@@4-@@@@ unit CA WL6-4@@4-@@@@ unit CA WL20-4@@4-@@@@ unit CA II WL208-4@@4-@@@@ unit CA WL20-4@@4-@@@@ unit CA WL22-4@@4-@@@@ unit CA WL26-4@@4-@@@@ unit CA WL220-4@@4-@@@@ unit CA WL225-4@@4-@@@@ unit CA WL232-4@@4-@@@@ unit CA WL240-4@@4-@@@@ unit CA III WL340-4@@4-@@@@ unit CA WL350-4@@4-@@@@ unit CA WL363-4@@4-@@@@ unit CA H Options Additional price Non-automatic air circuit Without Electronic Trip Units AA None breakers 2) Electronic Trip Units Operating mechanism, auxiliary release, auxiliary switch Versions without ground-fault protection ETU5B: Protection functions LI 5) BB ETU25B: Protection functions LSI CB ETU45B: Protection functions LSIN 3) EB ETU45B: Protection functions LSIN 3) FB with 4-line display ETU76B: Protection functions LSIN 3) with graphics display NB Versions with ground-fault protection ETU27B: Protection functions LSING 3) DG ETU45B: Protection functions LSING 3)4) EG ETU45B: Protection functions LSING 3)4) FG with 4-line display ETU76B: Protection functions LSING 3)4) with graphics display NG Manual operating mechanism with mechanical closing, without st and 2nd auxiliary releases; auxiliary switch 2 NC + 2 NO For further Article No. supplements, see page /44 AA2 None Additional price ) The rated current is determined by the rating plug. For the standard version, the supplied module is equal to the maximum rated current. If a lower rated current is required, adaptation by order code, see page /45. 2) For permissible rated short-time current I cc and rated short-circuit making capacity I cm for non-automatic air circuit breakers, see page /3. /34 Siemens LV 0 206/207 3) Current transformers for protection of the N-conductor and current transformers for detection of the ground-fault current in the grounded neutral point of the transformer are to be ordered separately, see page /58. The internal current transformers for N-conductors can be ordered by adding the supplement " Z" and the order code "F23", see page /47. 4) ETU45B to ETU76B with ground-fault protection module GFM AT (alarm and tripping), see page /58. 5) ETU5B cannot be used with 3WL circuit breakers, size III.

35 3WL /Non-Automatic Max. rated circuit breaker current I n max. Rated current ) I n Breaking capacity DT I cu 85/00 ka at 500 V, I cu = I cs high breaking capacity H Article No. 4-pole, fixed-mounted versions Basic price SET, M) A A ka Front main circuit connection, single hole II WL208-4@@43-@@@@ unit CA WL20-4@@43-@@@@ unit CA WL22-4@@43-@@@@ unit CA WL26-4@@43-@@@@ unit CA WL220-4@@43-@@@@ unit CA WL225-4@@43-@@@@ unit CA WL232-4@@43-@@@@ unit CA III WL340-4@@43-@@@@ unit CA Front main circuit connection, double hole I WL06-4@@44-@@@@ unit CA WL08-4@@44-@@@@ unit CA WL0-4@@44-@@@@ unit CA WL2-4@@44-@@@@ unit CA WL6-4@@44-@@@@ unit CA WL20-4@@44-@@@@ unit CA II WL208-4@@44-@@@@ unit CA WL20-4@@44-@@@@ unit CA WL22-4@@44-@@@@ unit CA WL26-4@@44-@@@@ unit CA WL220-4@@44-@@@@ unit CA WL225-4@@44-@@@@ unit CA WL232-4@@44-@@@@ unit CA III WL340-4@@44-@@@@ unit CA H Options Additional price ) The rated current is determined by the rating plug. For the standard version, the supplied module is equal to the maximum rated current. If a lower rated current is required, adaptation by order code, see page /45. 2) For permissible rated short-time current I cc and rated short-circuit making capacity I cm for non-automatic air circuit breakers, see page /3. 3) Current transformers for protection of the N-conductor and current transformers for detection of the ground-fault current in the grounded neutral point of the transformer are to be ordered separately, see page /58. The internal current transformers for N-conductors can be ordered by adding the supplement " Z" and the order code "F23", see page /47. 4) ETU45B to ETU76B with ground-fault protection module GFM AT (alarm and tripping), see page /58. 5) ETU5B cannot be used with 3WL circuit breakers, size III. Additional price Non-automatic air circuit Without Electronic Trip Units AA None breakers 2) Electronic Trip Units Operating mechanism, auxiliary release, auxiliary switch Versions without ground-fault protection ETU5B: Protection functions LI 5) BB ETU25B: Protection functions LSI CB ETU45B: Protection functions LSIN 3) EB ETU45B: Protection functions LSIN 3) FB with 4-line display ETU76B: Protection functions LSIN 3) with graphics display NB Versions with ground-fault protection ETU27B: Protection functions LSING 3) DG ETU45B: Protection functions LS- EG ING 3)4) ETU45B: Protection functions LSING 3)4) with 4-line display ETU76B: Protection functions LS- ING 3)4) with graphics display Manual operating mechanism with mechanical closing, without st and 2nd auxiliary releases; auxiliary switch 2 NC + 2 NO For further Article No. supplements, see page /44 FG NG AA2 None Siemens LV 0 206/207 /35

36 3WL /Non-Automatic 4-pole, fixed-mounted versions Max. rated circuit breaker current I n max. Rated current ) I n Breaking capacity DT I cu 30/50 ka at 500 V, I cu = I cs very high breaking capacity C Article No. Basic price SET, M) A A ka Horizontal main circuit connection II WL26-5@@42-@@@@ unit CA WL220-5@@42-@@@@ unit CA WL225-5@@42-@@@@ unit CA WL232-5@@42-@@@@ unit CA III WL340-5@@42-@@@@ unit CA WL350-5@@42-@@@@ unit CA Vertical main circuit connection II WL26-5@@4-@@@@ unit CA WL220-5@@4-@@@@ unit CA WL225-5@@4-@@@@ unit CA WL232-5@@4-@@@@ unit CA III WL340-5@@4-@@@@ unit CA WL350-5@@4-@@@@ unit CA WL363-5@@4-@@@@ unit CA C Options Additional price Non-automatic air circuit Without Electronic Trip Units AA None breakers 2) Electronic Trip Units Operating mechanism, auxiliary release, auxiliary switch Versions without ground-fault protection ETU5B: Protection functions LI 3) BB ETU25B: Protection functions LSI CB ETU45B: Protection functions LSIN 4) EB ETU45B: Protection functions LSIN 4) FB with 4-line display ETU76B: Protection functions LSIN 4) with graphics display NB Versions with ground-fault protection ETU27B: Protection functions LSING 4) DG ETU45B: Protection functions LS- EG ING 4)5) ETU45B: Protection functions LSING 4)5) with 4-line display ETU76B: Protection functions LS- ING 4)5) with graphics display Manual operating mechanism with mechanical closing, without st and 2nd auxiliary releases; auxiliary switch 2 NC + 2 NO For further Article No. supplements, see page /44 FG NG AA2 None Additional price ) The rated current is determined by the rating plug. For the standard version, the supplied module is equal to the maximum rated current. If a lower rated current is required, adaptation by order code, see page /45. 2) For permissible rated short-time current I cc and rated short-circuit making capacity I cm for non-automatic air circuit breakers, see page /3. 3) ETU5B cannot be used with 3WL circuit breakers, size III. 4) Current transformers for protection of the N-conductor and current transformers for detection of the ground-fault current in the grounded neutral point of the transformer are to be ordered separately, see page /58. The internal current transformers for N-conductors can be ordered by adding the supplement " Z" and the order code "F23", see page /47. 5) ETU45B to ETU76B with ground-fault protection module GFM AT (alarm and tripping), see page /58. /36 Siemens LV 0 206/207

37 3WL /Non-Automatic Selection and ordering data Max. rated circuit breaker current I n max. Rated current ) I n Breaking capacity DT I cu 55/66 ka at 500 V, I cu = I cs ECO breaking capacity N Article No. Basic price 4-pole, withdrawable versions SET, M) A A ka Without guide frames 2) (for guide frames, see pages /52 to /57) I WL06-2@@45-@@@@ unit CA WL08-2@@45-@@@@ unit CA WL0-2@@45-@@@@ unit CA WL2-2@@45-@@@@ unit CA WL6-2@@45-@@@@ unit CA WL20-2@@45-@@@@ unit CA II WL208-2@@45-@@@@ unit CA WL20-2@@45-@@@@ unit CA WL22-2@@45-@@@@ unit CA WL26-2@@45-@@@@ unit CA WL220-2@@45-@@@@ unit CA WL225-2@@45-@@@@ unit CA WL232-2@@45-@@@@ unit CA WL240-2@@45-@@@@ unit CA With guide frames, horizontal main circuit connection I WL06-2@@46-@@@@ unit CA WL08-2@@46-@@@@ unit CA WL0-2@@46-@@@@ unit CA WL2-2@@46-@@@@ unit CA WL6-2@@46-@@@@ unit CA WL20-2@@46-@@@@ unit CA II WL208-2@@46-@@@@ unit CA WL20-2@@46-@@@@ unit CA WL22-2@@46-@@@@ unit CA WL26-2@@46-@@@@ unit CA WL220-2@@46-@@@@ unit CA WL225-2@@46-@@@@ unit CA WL232-2@@46-@@@@ unit CA N Options Additional price Non-automatic air circuit Without Electronic Trip Units AA None breakers 3) Electronic Trip Units Operating mechanism, auxiliary release, auxiliary switch Versions without ground-fault protection ETU5B: Protection functions LI BB ETU25B: Protection functions LSI CB ETU45B: Protection functions LSIN 4) EB ETU45B: Protection functions LSIN 4) FB with 4-line display ETU76B: Protection functions LSIN 4) with graphics display NB Versions with ground-fault protection ETU27B: Protection functions LS- DG ING 4) ETU45B: Protection functions LS- EG ING 4)5) ETU45B: Protection functions LSING 4)5) with 4-line display ETU76B: Protection functions LS- ING 4)5) with graphics display Manual operating mechanism with mechanical closing, without st and 2nd auxiliary releases; auxiliary switch 2 NC + 2 NO For further Article No. supplements, see page /44 FG NG AA2 None Additional price ) The rated current is determined by the rating plug. For the standard version, the supplied module is equal to the maximum rated current. If a lower rated current is required, adaptation by order code, see page /45. 2) Z options which are installed on the guide frame are not available. 3) For permissible rated short-time current I cc and rated short-circuit making capacity I cm for non-automatic air circuit breakers, see page /3. 4) Current transformers for protection of the N-conductor and current transformers for detection of the ground-fault current in the grounded neutral point of the transformer are to be ordered separately, see page /58. The internal current transformers for N-conductors can be ordered by adding the supplement " Z" and the order code "F23", see page /47. 5) ETU45B to ETU76B with ground-fault protection module GFM AT (alarm and tripping), see page /58. Siemens LV 0 206/207 /37

38 3WL /Non-Automatic 4-pole, withdrawable versions Max. rated circuit breaker current I n max. Rated current ) I n Breaking capacity DT I cu 55/66 ka at 500 V, I cu = I cs ECO breaking capacity N Article No. Basic price SET, M) A A ka With guide frames, vertical main circuit connection I WL06-2@@47-@@@@ unit CA WL08-2@@47-@@@@ unit CA WL0-2@@47-@@@@ unit CA WL2-2@@47-@@@@ unit CA WL6-2@@47-@@@@ unit CA WL20-2@@47-@@@@ unit CA II WL208-2@@47-@@@@ unit CA WL20-2@@47-@@@@ unit CA WL22-2@@47-@@@@ unit CA WL26-2@@47-@@@@ unit CA WL220-2@@47-@@@@ unit CA WL225-2@@47-@@@@ unit CA WL232-2@@47-@@@@ unit CA WL240-2@@47-@@@@ unit CA With guide frames, connecting flanges I WL06-2@@48-@@@@ unit CA WL08-2@@48-@@@@ unit CA WL0-2@@48-@@@@ unit CA WL2-2@@48-@@@@ unit CA WL6-2@@48-@@@@ unit CA WL20-2@@48-@@@@ unit CA II WL208-2@@48-@@@@ unit CA WL20-2@@48-@@@@ unit CA WL22-2@@48-@@@@ unit CA WL26-2@@48-@@@@ unit CA WL220-2@@48-@@@@ unit CA WL225-2@@48-@@@@ unit CA WL232-2@@48-@@@@ unit CA N Options Additional price Non-automatic air circuit Without Electronic Trip Units AA None breakers 3) Electronic Trip Units Operating mechanism, auxiliary release, auxiliary switch Versions without ground-fault protection ETU5B: Protection functions LI BB ETU25B: Protection functions LSI CB ETU45B: Protection functions LSIN 4) EB ETU45B: Protection functions LSIN 4) FB with 4-line display ETU76B: Protection functions LSIN 4) with graphics display NB Versions with ground-fault protection ETU27B: Protection functions LS- DG ING 4) ETU45B: Protection functions LS- EG ING 4)5) ETU45B: Protection functions LSING 4)5) with 4-line display ETU76B: Protection functions LS- ING 4)5) with graphics display Manual operating mechanism with mechanical closing, without st and 2nd auxiliary releases; auxiliary switch 2 NC + 2 NO For further Article No. supplements, see page /44 FG NG AA2 None Additional price ) The rated current is determined by the rating plug. For the standard version, the supplied module is equal to the maximum rated current. If a lower rated current is required, adaptation by order code, see page /45. 2) Z options which are installed on the guide frame are not available. 3) For permissible rated short-time current I cc and rated short-circuit making capacity I cm for non-automatic air circuit breakers, see page /3. 4) Current transformers for protection of the N-conductor and current transformers for detection of the ground-fault current in the grounded neutral point of the transformer are to be ordered separately, see page /58. The internal current transformers for N-conductors can be ordered by adding the supplement " Z" and the order code "F23", see page /47. 5) ETU45B to ETU76B with ground-fault protection module GFM AT (alarm and tripping), see page /58. /38 Siemens LV 0 206/207

39 3WL /Non-Automatic Max. rated circuit breaker current I n max. Rated current ) I n Breaking capacity DT I cu 66/80 ka at 500 V, I cu = I cs standard breaking capacity S Article No. Basic price 4-pole, withdrawable versions SET, M) A A ka Without guide frames 2) (for guide frames, see pages /52 to /57) I WL06-3@@45-@@@@ unit CA WL08-3@@45-@@@@ unit CA WL0-3@@45-@@@@ unit CA WL2-3@@45-@@@@ unit CA WL6-3@@45-@@@@ unit CA WL20-3@@45-@@@@ unit CA II WL208-3@@45-@@@@ unit CA WL20-3@@45-@@@@ unit CA WL22-3@@45-@@@@ unit CA WL26-3@@45-@@@@ unit CA WL220-3@@45-@@@@ unit CA WL225-3@@45-@@@@ unit CA WL232-3@@45-@@@@ unit CA WL240-3@@45-@@@@ unit CA With guide frames, horizontal main circuit connection I WL06-3@@46-@@@@ unit CA WL08-3@@46-@@@@ unit CA WL0-3@@46-@@@@ unit CA WL2-3@@46-@@@@ unit CA WL6-3@@46-@@@@ unit CA WL20-3@@46-@@@@ unit CA II WL208-3@@46-@@@@ unit CA WL20-3@@46-@@@@ unit CA WL22-3@@46-@@@@ unit CA WL26-3@@46-@@@@ unit CA WL220-3@@46-@@@@ unit CA WL225-3@@46-@@@@ unit CA WL232-3@@46-@@@@ unit CA S Options Additional price Non-automatic air circuit Without Electronic Trip Units AA None breakers 3) Electronic Trip Units Operating mechanism, auxiliary release, auxiliary switch Versions without ground-fault protection ETU5B: Protection functions LI BB ETU25B: Protection functions LSI CB ETU45B: Protection functions LSIN 4) EB ETU45B: Protection functions LSIN 4) FB with 4-line display ETU76B: Protection functions LSIN 4) with graphics display NB Versions with ground-fault protection ETU27B: Protection functions LS- DG ING 4) ETU45B: Protection functions LS- EG ING 4)5) ETU45B: Protection functions LSING 4)5) with 4-line display ETU76B: Protection functions LS- ING 4)5) with graphics display Manual operating mechanism with mechanical closing, without st and 2nd auxiliary releases; auxiliary switch 2 NC + 2 NO For further Article No. supplements, see page /44 FG NG AA2 None Additional price ) The rated current is determined by the rating plug. For the standard version, the supplied module is equal to the maximum rated current. If a lower rated current is required, adaptation by order code, see page /45. 2) Z options which are installed on the guide frame are not available. 3) For permissible rated short-time current I cc and rated short-circuit making capacity I cm for non-automatic air circuit breakers, see page /3. 4) Current transformers for protection of the N-conductor and current transformers for detection of the ground-fault current in the grounded neutral point of the transformer are to be ordered separately, see page /58. The internal current transformers for N-conductors can be ordered by adding the supplement " Z" and the order code "F23", see page /47. 5) ETU45B to ETU76B with ground-fault protection module GFM AT (alarm and tripping), see page /58. Siemens LV 0 206/207 /39

40 3WL /Non-Automatic 4-pole, withdrawable versions Max. rated circuit breaker current I n max. Rated current ) I n Breaking capacity DT I cu 66/80 ka at 500 V, I cu = I cs standard breaking capacity S Article No. Basic price SET, M) A A ka With guide frames, vertical main circuit connection I WL06-3@@47-@@@@ unit CA WL08-3@@47-@@@@ unit CA WL0-3@@47-@@@@ unit CA WL2-3@@47-@@@@ unit CA WL6-3@@47-@@@@ unit CA WL20-3@@47-@@@@ unit CA II WL208-3@@47-@@@@ unit CA WL20-3@@47-@@@@ unit CA WL22-3@@47-@@@@ unit CA WL26-3@@47-@@@@ unit CA WL220-3@@47-@@@@ unit CA WL225-3@@47-@@@@ unit CA WL232-3@@47-@@@@ unit CA WL240-3@@47-@@@@ unit CA With guide frames, connecting flanges I WL06-3@@48-@@@@ unit CA WL08-3@@48-@@@@ unit CA WL0-3@@48-@@@@ unit CA WL2-3@@48-@@@@ unit CA WL6-3@@48-@@@@ unit CA WL20-3@@48-@@@@ unit CA II WL208-3@@48-@@@@ unit CA WL20-3@@48-@@@@ unit CA WL22-3@@48-@@@@ unit CA WL26-3@@48-@@@@ unit CA WL220-3@@48-@@@@ unit CA WL225-3@@48-@@@@ unit CA WL232-3@@48-@@@@ unit CA S Options Additional price Non-automatic air circuit Without Electronic Trip Units AA None breakers 3) Electronic Trip Units Operating mechanism, auxiliary release, auxiliary switch Versions without ground-fault protection ETU5B: Protection functions LI BB ETU25B: Protection functions LSI CB ETU45B: Protection functions LSIN 4) EB ETU45B: Protection functions LSIN 4) FB with 4-line display ETU76B: Protection functions LSIN 4) with graphics display NB Versions with ground-fault protection ETU27B: Protection functions LS- DG ING 4) ETU45B: Protection functions LS- EG ING 4)5) ETU45B: Protection functions LSING 4)5) with 4-line display ETU76B: Protection functions LS- ING 4)5) with graphics display Manual operating mechanism with mechanical closing, without st and 2nd auxiliary releases; auxiliary switch 2 NC + 2 NO For further Article No. supplements, see page /44 FG NG AA2 None Additional price ) The rated current is determined by the rating plug. For the standard version, the supplied module is equal to the maximum rated current. If a lower rated current is required, adaptation by order code, see page /45. 2) Z options which are installed on the guide frame are not available. 3) For permissible rated short-time current I cc and rated short-circuit making capacity I cm for non-automatic air circuit breakers, see page /3. 4) Current transformers for protection of the N-conductor and current transformers for detection of the ground-fault current in the grounded neutral point of the transformer are to be ordered separately, see page /58. The internal current transformers for N-conductors can be ordered by adding the supplement " Z" and the order code "F23", see page /47. 5) ETU45B to ETU76B with ground-fault protection module GFM AT (alarm and tripping), see page /58. /40 Siemens LV 0 206/207

41 3WL /Non-Automatic Max. rated circuit breaker current I n max. Rated current ) I n Breaking capacity DT I cu 85/00 ka at 500 V, I cu = I cs high breaking capacity H Article No. Basic price 4-pole, withdrawable versions SET, M) A A ka Without guide frames 2) (for guide frames, see pages /52 to /57) I WL06-4@@45-@@@@ unit CA WL08-4@@45-@@@@ unit CA WL0-4@@45-@@@@ unit CA WL2-4@@45-@@@@ unit CA WL6-4@@45-@@@@ unit CA WL20-4@@45-@@@@ unit CA II WL208-4@@45-@@@@ unit CA WL20-4@@45-@@@@ unit CA WL22-4@@45-@@@@ unit CA WL26-4@@45-@@@@ unit CA WL220-4@@45-@@@@ unit CA WL225-4@@45-@@@@ unit CA WL232-4@@45-@@@@ unit CA WL240-4@@45-@@@@ unit CA III WL340-4@@45-@@@@ unit CA WL350-4@@45-@@@@ unit CA WL363-4@@45-@@@@ unit CA With guide frames, horizontal main circuit connection I WL06-4@@46-@@@@ unit CA WL08-4@@46-@@@@ unit CA WL0-4@@46-@@@@ unit CA WL2-4@@46-@@@@ unit CA WL6-4@@46-@@@@ unit CA WL20-4@@46-@@@@ unit CA II WL208-4@@46-@@@@ unit CA WL20-4@@46-@@@@ unit CA WL22-4@@46-@@@@ unit CA WL26-4@@46-@@@@ unit CA WL220-4@@46-@@@@ unit CA WL225-4@@46-@@@@ unit CA WL232-4@@46-@@@@ unit CA III WL340-4@@46-@@@@ unit CA WL350-4@@46-@@@@ unit CA H Options Additional price ) The rated current is determined by the rating plug. For the standard version, the supplied module is equal to the maximum rated current. If a lower rated current is required, adaptation by order code, see page /45. 2) Z options which are installed on the guide frame are not available. 3) For permissible rated short-time current I cc and rated short-circuit making capacity I cm for non-automatic air circuit breakers, see page /3. Additional price Non-automatic air circuit Without Electronic Trip Units AA None breakers 3) Electronic Trip Units Operating mechanism, auxiliary release, auxiliary switch Versions without ground-fault protection ETU5B: Protection functions LI 6) BB ETU25B: Protection functions LSI CB ETU45B: Protection functions LSIN 4) EB ETU45B: Protection functions LSIN 4) FB with 4-line display ETU76B: Protection functions LSIN 4) with graphics display NB Versions with ground-fault protection ETU27B: Protection functions LSING 4) DG ETU45B: Protection functions LSING 4)5) EG ETU45B: Protection functions LSING 4)5) FG with 4-line display ETU76B: Protection functions LSING 4)5) with graphics display NG Manual operating mechanism with mechanical closing, without st and 2nd auxiliary releases; auxiliary switch 2 NC + 2 NO For further Article No. supplements, see page /44 AA2 None 4) Current transformers for protection of the N-conductor and current transformers for detection of the ground-fault current in the grounded neutral point of the transformer are to be ordered separately, see page /58. The internal current transformers for N-conductors can be ordered by adding the supplement " Z" and the order code "F23", see page /47. 5) ETU45B to ETU76B with ground-fault protection module GFM AT (alarm and tripping), see page /58. 6) ETU5B cannot be used with 3WL circuit breakers, size III. Siemens LV 0 206/207 /4

42 3WL /Non-Automatic 4-pole, withdrawable versions Max. rated circuit breaker current I n max. Rated current ) I n Breaking capacity DT I cu 85/00 ka at 500 V, I cu = I cs high breaking capacity H Article No. Basic price SET, M) A A ka With guide frames, vertical main circuit connection I WL06-4@@47-@@@@ unit CA WL08-4@@47-@@@@ unit CA WL0-4@@47-@@@@ unit CA WL2-4@@47-@@@@ unit CA WL6-4@@47-@@@@ unit CA WL20-4@@47-@@@@ unit CA II WL208-4@@47-@@@@ unit CA WL20-4@@47-@@@@ unit CA WL22-4@@47-@@@@ unit CA WL26-4@@47-@@@@ unit CA WL220-4@@47-@@@@ unit CA WL225-4@@47-@@@@ unit CA WL232-4@@47-@@@@ unit CA WL240-4@@47-@@@@ unit CA III WL340-4@@47-@@@@ unit CA WL350-4@@47-@@@@ unit CA WL363-4@@47-@@@@ unit CA With guide frames, connecting flanges I WL06-4@@48-@@@@ unit CA WL08-4@@48-@@@@ unit CA WL0-4@@48-@@@@ unit CA WL2-4@@48-@@@@ unit CA WL6-4@@48-@@@@ unit CA WL20-4@@48-@@@@ unit CA II WL208-4@@48-@@@@ unit CA WL20-4@@48-@@@@ unit CA WL22-4@@48-@@@@ unit CA WL26-4@@48-@@@@ unit CA WL220-4@@48-@@@@ unit CA WL225-4@@48-@@@@ unit CA WL232-4@@48-@@@@ unit CA III WL340-4@@48-@@@@ unit CA H Options Additional price Non-automatic air circuit Without Electronic Trip Units AA None breakers 3) Electronic Trip Units Operating mechanism, auxiliary release, auxiliary switch Versions without ground-fault protection ETU5B: Protection functions LI 6) BB ETU25B: Protection functions LSI CB ETU45B: Protection functions LSIN 4) EB ETU45B: Protection functions LSIN 4) FB with 4-line display ETU76B: Protection functions LSIN 4) with graphics display NB Versions with ground-fault protection ETU27B: Protection functions LSING 4) DG ETU45B: Protection functions LSING 4)5) EG ETU45B: Protection functions LSING 4)5) FG with 4-line display ETU76B: Protection functions LSING 4)5) with graphics display NG Manual operating mechanism with mechanical closing, without st and 2nd auxiliary releases; auxiliary switch 2 NC + 2 NO For further Article No. supplements, see page /44 AA2 None Additional price ) The rated current is determined by the rating plug. For the standard version, the supplied module is equal to the maximum rated current. If a lower rated current is required, adaptation by order code, see page /45. 2) Z options which are installed on the guide frame are not available. 3) For permissible rated short-time current I cc and rated short-circuit making capacity I cm for non-automatic air circuit breakers, see page /3. 4) Current transformers for protection of the N-conductor and current transformers for detection of the ground-fault current in the grounded neutral point of the transformer are to be ordered separately, see page /58. The internal current transformers for N-conductors can be ordered by adding the supplement " Z" and the order code "F23", see page /47. 5) ETU45B to ETU76B with ground-fault protection module GFM AT (alarm and tripping), see page /58. 6) ETU5B cannot be used with 3WL circuit breakers, size III. /42 Siemens LV 0 206/207

43 3WL /Non-Automatic Max. rated circuit breaker current I n max. Rated current ) I n Breaking capacity DT I cu 30/50 ka at 500 V, I cu = I cs very high breaking capacity C Article No. 4-pole, withdrawable versions Basic price SET, M) A A ka Without guide frames 2) (for guide frames, see pages /52 to /57) II WL26-5@@45-@@@@ unit CA WL220-5@@45-@@@@ unit CA WL225-5@@45-@@@@ unit CA WL232-5@@45-@@@@ unit CA III WL340-5@@45-@@@@ unit CA WL350-5@@45-@@@@ unit CA WL363-5@@45-@@@@ unit CA With guide frames, horizontal main circuit connection II WL26-5@@46-@@@@ unit CA WL220-5@@46-@@@@ unit CA WL225-5@@46-@@@@ unit CA WL232-5@@46-@@@@ unit CA III WL340-5@@46-@@@@ unit CA WL350-5@@46-@@@@ unit CA With guide frames, vertical main circuit connection II WL26-5@@47-@@@@ unit CA WL220-5@@47-@@@@ unit CA WL225-5@@47-@@@@ unit CA WL232-5@@47-@@@@ unit CA III WL340-5@@47-@@@@ unit CA WL350-5@@47-@@@@ unit CA WL363-5@@47-@@@@ unit CA C Options Additional price Non-automatic air circuit Without Electronic Trip Units AA None breakers 3) Electronic Trip Units Operating mechanism, auxiliary release, auxiliary switch Versions without ground-fault protection ETU5B: Protection functions LI 4) BB ETU25B: Protection functions LSI CB ETU45B: Protection functions LSIN 5) EB ETU45B: Protection functions LSIN 5) FB with 4-line display ETU76B: Protection functions LSIN 5) with graphics display NB Versions with ground-fault protection ETU27B: Protection functions LS- DG ING 5) ETU45B: Protection functions LS- EG ING 5)6) ETU45B: Protection functions LSING 5)6) with 4-line display ETU76B: Protection functions LS- ING 5)6) with graphics display Manual operating mechanism with mechanical closing, without st and 2nd auxiliary releases; auxiliary switch 2 NC + 2 NO For further Article No. supplements, see page /44 FG NG AA2 None Additional price ) The rated current is determined by the rating plug. For the standard version, the supplied module is equal to the maximum rated current. If a lower rated current is required, adaptation by order code, see page /45. 2) Z options which are installed on the guide frame are not available. 3) For permissible rated short-time current I cc and rated short-circuit making capacity I cm for non-automatic air circuit breakers, see page /3. 4) ETU5B cannot be used with 3WL circuit breakers, size III. 5) Current transformers for protection of the N-conductor and current transformers for detection of the ground-fault current in the grounded neutral point of the transformer are to be ordered separately, see page /58. The internal current transformers for N-conductors can be ordered by adding the supplement " Z" and the order code "F23", see page /47. 6) ETU45B to ETU76B with ground-fault protection module GFM AT (alarm and tripping), see page /58. Siemens LV 0 206/207 /43

44 3WL /Non-Automatic Options Selection and ordering data Operating mechanisms Additional price Article No. supplement 3WL... Additional price Manual operating mechanism with mechanical closing None Manual operating mechanism with mechanical and electrical closing, closing coil suitable for uninterrupted duty, 00 % OP 50/60 Hz V AC V DC Manual/motorized operating mechanism with mechanical and electrical closing, closing coil suitable for uninterrupted duty, 00 % OP Motor Closing solenoid 50/60 Hz V AC V DC 50/60 Hz V AC V DC Note To order different voltages for motorized operating mechanism and closing solenoid or closing coil for synchronization purposes: "" at the 3th digit of the Article No. and order codes, see page /46. st auxiliary release Type Condition U s 50/60 Hz V AC U s V DC Without st auxiliary release Shunt release suitable for uninterrupted duty, 00 % OP 2nd auxiliary release A None Operating range 24 B U s 30 C Type Condition U s 50/60 Hz V AC U s V DC Without 2nd auxiliary release Shunt release suitable for uninterrupted duty, 00 % OP Undervoltage release, instantaneous ( 80 ms), short-delay ( 200 ms) 48 D 60 E F G A None Operating range 24 B U s 30 C 48 D 60 E F G Operating range 24 J U s 30 K 48 L 60 U M N P Undervoltage release, Operating range 48 Q can be delayed between U s R 0.2 s and 3.2 s S Auxiliary switches st auxiliary switch block T 2 NO + 2 NC 2 None st + 2nd auxiliary switch block 4 NO + 4 NC 4 6 NO + 2 NC 7 5 NO + 3 NC 8 /44 Siemens LV 0 206/207

45 3WL /Non-Automatic Add "-Z" to the complete Article No. and indicate the appropriate order @ Options Additional price Operating manuals Printed version French/Italian A Spanish/Portuguese A 2 Rated voltage 000 V AC and 690 V IT networks Additional price Additional price Conditions Rated current I n 3-pole 4-pole Only for circuit breakers with high breaking I ) Up to 2000 A A 0 5 capacity H (8th digit of the Article No. is a "4"). II )2) Up to 2000 A A 0 5 Cannot be combined with rated voltage 50 V AC order code "A5" A A A A 0 5 Rated voltage 50 V AC Additional price ) If ordering withdrawable circuit breaker and guide frame separately, specify order code "A05" for withdrawable circuit breaker and guide frame. 2) Not possible for circuit breakers with very high breaking capacity C. 3) Not necessary for circuit breakers with very high breaking capacity C as these circuit breakers can be used as standard up to 50 V AC. 4) Front connections are tinned as standard. 5) The permissible temperature-rise limits according to IEC are 5 K lower for a tin surface than for a silver surface. III )3) 4000 A A A A A A 0 5 Conditions Rated current I n Only for circuit breakers with high breaking II 2) Up to 2000 A A 5 capacity H (8th digit of the Article No. is a "4") A A 5 Cannot be combined with rated voltage 000 V AC order code "A05" A A A A 5 Note For size III select a circuit breaker with very high breaking capacity C, which can be used as standard up to 50 V AC. Rated voltage 690 V AC (+ 20 %) Conditions Rated current I n Only for 3WL circuit breakers, size I, with high breaking capacity H (8th digit of the Article No. is a "4"). I Up to 2000 A A 6 Tinned version of the customer's connections on the guide frame 4)5) Conditions Only for circuit breakers in withdrawable version with horizontal connection or flange connection. The normal delivery time increases to 5 work days. Special packaging (moisture protection) Special packaging for extended technical requirements Cardboard packaging with water-repellent coating on corrugated cardboard (moisture protection) Rating plugs Conditions Rated current I n A Only one module is possible per circuit breaker (not in conjunction with Electronic Trip Unit ETU5B). As standard the Electronic Trip Units are equipped with a rating plug which is equal to the maximum rated current circuit breaker (I n max ). The rated current of the selected rating plug must be smaller than I n max. I A 0 8 II A 0 8 III A 0 8 A 6 Additional price Additional price I, II 250 B 0 2 None 35 B 0 3 None 400 B 0 4 None 500 B 0 5 None 630 B 0 6 None 800 B 0 8 None 000 B 0 None I, II, III 250 B 2 None 600 B 6 None 2000 B 2 0 None II, III 2500 B 2 5 None 3200 B 3 2 None 4000 B 4 0 None III 5000 B 5 0 None 6300 B 6 3 None Siemens LV 0 206/207 /45

46 3WL /Non-Automatic Options Add "-Z" to the complete Article No. and indicate the appropriate order @ Additional price Indication/operator control elements, door sealing frames 5-digit mechanical operating cycles counter C 0 ) Electrical ON button S0 in the operator panel Button with sealing cap C 2) Possible only for circuit breakers with closing coil. Key operation with lock CES C 2 Storage status signaling switches 2) (S2) NO contact C 2 0 Ready-to-close signaling switches (S20) NO contact C 2 2 Signaling switches 2) For the first auxiliary release (S22) C 2 6 Motor shutdown switch in the operator panel 3) (S2) EMERGENCY-STOP pushbuttons Additional price ) Only possible with motorized operating mechanism. 2) Not possible with communications interface option, order codes "F02" or "F2". 3) Only for breakers with motorized operating mechanism, not possible with order codes "C", "C2". 4) Not available for non-automatic air circuit breakers. For the second auxiliary release (S23) C 2 7 Mushroom pushbutton instead of the mechanical OFF pushbutton Door sealing frames T 4 0 Reclosing lockout and remote resets Automatic reset of the reclosing lockout K 0 st tripped signaling switch 2)4) (S24) CO contact K 0 7 2nd tripped signaling switch 2)4)8) (S25) NO contact K 0 6 Type 50/60 Hz V AC V DC Remote reset solenoid for displays and 24 K 0 reset buttons 48 K including automatic reset of the reclosing lockout K K 3 Motorized operating mechanisms and closing/opening coils Type Conditions Motor Motorized operating mechanism Only possible if the 3th digit of the Article No. = "" 50/60 Hz V AC V DC Type Conditions Activation coils Closing coil suitable for uninterrupted duty, 00 % OP Only possible if the 3th digit of the Article No. = "" S 2 5 S M M M M /60 Hz V AC V DC Type Conditions Activation coils Closing coil 5) not suitable for uninterrupted duty, 5 % OP, synchronizable Only possible if the 3th digit of the Article No. = "" 24 M 2 30 M M M M M /60 Hz V AC V DC Type Conditions Activation coils Opening coils (shunt release) 6)7) Not suitable for uninterrupted duty, 5 % OP, synchronizable 24 M 3 48 M M M /60 Hz V AC V DC 24 M 4 48 M M M 4 6 5) Overexcited, i.e. operating time 50 ms (standard > 80 ms). 6) Only possible if the 4th position of the Article No. for the circuit breaker is "A", i.e. "without st auxiliary release". 7) Overexcited, i.e. operating time 50 ms (standard > 80 ms). 8) Only possible with option "K07". /46 Siemens LV 0 206/207

47 3WL /Non-Automatic Add "-Z" to the complete Article No. and indicate the appropriate order @ Options Additional price Interlocks, covers, position signaling switches (for fixed-mounted version) Mutual mechanical interlockings (interlocking module with Bowden wire 2 m) Fixed-mounted circuit breakers S 5 5 Interlocks, covers, position signaling switches (for withdrawable version) Mutual mechanical interlockings (interlocking module with Bowden wire 2 m) Version For withdrawable circuit breakers with guide frame R 5 5 For guide frames R 5 6 For withdrawable circuit breakers R 5 7 Arc chute covers Number of poles Not available for 3-pole I R V version (order code "A05") - DC version II R A size II III R 0-50 V version (order code "A5") - 30 ka version, size II 4-pole I R 0-50 ka version, size III II R 0 Shutters 2-part lockable with padlocks ) Position signaling switches for guide frames Number of poles III R 0 3-pole I R 2 II R 2 III R 2 4-pole I R 2 Connected position II R 2 III R 2 Test position Disconnected position CO CO CO R 5 3 CO 2 CO CO R 6 Communication and measurement functions Breaker status sensor (BSS) F 0 PROFIBUS-DP communications interface 2) Including COM5 and breaker status sensor (BSS) MODBUS-RTU communications interface 2) Including COM6 and breaker status sensor (BSS) Measurement function Plus (without PROFIBUS/MODBUS communications interface) 3) Overload and short-circuit protection for neutral conductors Internal current transformer for N conductor Only possible with 4-pole circuit breakers with ETU27B to ETU76B EMC filters F 0 2 F 2 F 0 5 I F 2 3 II F 2 3 III F 2 3 EMC filters F 3 Common-mode interference suppressor filters (e.g. in IT networks, caused by frequency converters) Insertion loss (asymmetric) in the range 40 khz to 0 MHz >40 db. Additional price ) Padlocks not included in scope of supply. 2) If ordering the withdrawable circuit breaker and guide frame separately, specify order code "F02" or "F2" for the withdrawable circuit breaker only. 3) Additional voltage transformers are required for connection of the Plus measurement function, see page /67. Siemens LV 0 206/207 /47

48 3WL /Non-Automatic Options Add "-Z" to the complete Article No. and indicate the appropriate order @ Additional price Locking devices (for fixed-mounted versions and withdrawable versions) Locking devices against unauthorized closing, in the operator panels The disconnector unit fulfills the requirements for main circuit breakers according to EN EMERGENCY-STOP pushbuttons Additional price ) Locks must be ordered from the manufacturer 2) Padlock not included in the scope of supply 3) Not available in combination with R50 4) Not available in combination with R40 5) Combination with R8, R85 and R86 on request Version Made by CES S 0 Made by IKON S 0 3 Assembly kit FORTRESS or Castell ) S 0 5 Assembly kit for padlocks 2) S 0 7 Made by Ronis S 0 8 Made by Profalux S 0 9 Mushroom pushbutton instead of the mechanical OFF pushbutton Locking devices for operating mechanism S 3 3 handles with padlock 2) Locking devices (for withdrawable version) Locking devices against unauthorized closing, for withdrawable circuit breakers The disconnector unit fulfills the requirements for main circuit breakers acc. to EN , consisting of a lock in the cabinet door, active in the connected position, function is retained when circuit breaker is replaced. Not possible in combination with order codes "R8", "R85" or "R86". Version S 2 4 Made by CES R 6 Made by Ronis R 6 8 Made by Profalux R 6 0 Locking devices to prevent movement of Version the withdrawable circuit breakers Made by CES S 7 Safety lock for mounting on the circuit breaker Made by Profalux S 7 5 Made by Ronis S 7 6 Locking mechanisms (for fixed-mounted versions) Locking devices Not possible in combination with order codes "R8", "R85" or "R86". Locking devices (for withdrawable version) Locking devices Not possible in combination with order codes "R8", "R85" or "R86". To prevent opening of the cabinet door in ON position Version To prevent opening of the cabinet door in connected position S 3 0 R 3 0 To prevent activation when the cabinet door is R 4 0 open 3)5) To prevent movement with the cabinet door R 5 0 open 4) Locking mechanism to prevent movement Version of the withdrawable circuit breakers in Made by CES R 8 disconnected position, consisting of Bowden wire and lock in the cabinet door Made by Ronis R 8 5 Not possible in combination with order codes "R30", "R50", "R6", "R68" or "R60". Made by Profalux R 8 6 Connection methods for auxiliary conductors (for fixed-mounted and withdrawable versions) Connections for screwless terminals (tension spring) Version Fixed-mounted N 6 Withdrawable P 6 /48 Siemens LV 0 206/207

49 3WL /Non-Automatic Add "-Z" to the complete Article No. and indicate the appropriate order @ Options Additional price For withdrawable circuit breakers with guide frames or for guide frames ) Note To select this connection method the 2th digit of the Article No. for the circuit breaker must be a "6". Additional price 3-pole Additional price 4-pole Connection methods for main connections Rated current I n Top and bottom: ) 2) I Up to 600 A P 0 0 accessible from front, II Up to 2000 A P 0 0 single hole Up to 2500 A P 0 0 Additional price ) Cannot be used for size II and III circuit breakers with very high breaking capacity C 2) Not for 3WL size I with high breaking capacity H Up to 3200 A P 0 0 III Up to 4000 A P 0 0 Connection methods for main connections Rated current I n Top and bottom: ) I Up to 2000 A P 0 accessible from front, II Up to 2000 A P 0 double hole Up to 2500 A P 0 Up to 3200 A P 0 III Up to 4000 A P 0 Connection methods for main connections Rated current I n Top: ) 2) I Up to 600 A P 0 7 horizontal II Up to 2000 A P 0 7 Bottom: accessible from front, Up to 2500 A P 0 7 single hole Up to 3200 A P 0 7 III Up to 4000 A P 0 7 Connection methods for main connections Rated current I n Top: I Up to 2000 A P 8 vertical II Up to 2000 A P 8 Bottom: horizontal Up to 2500 A P 8 Up to 3200 A P 8 III Up to 4000 A P 8 Up to 5000 A P 8 Connection methods for main connections Rated current I n Top: ) I Up to 2000 A P 9 connection flange II Up to 2000 A P 9 Bottom: horizontal Up to 2500 A P 9 Up to 3200 A P 9 III Up to 4000 A P 9 Connection methods for main connections Rated current I n Top: I Up to 2000 A P 2 3 horizontal II Up to 2000 A P 2 3 Bottom: vertical Up to 2500 A P 2 3 Up to 3200 A P 2 3 III Up to 4000 A P 2 3 Up to 5000 A P 2 3 Connection methods for main connections Rated current I n Top: ) I Up to 2000 A P 2 8 horizontal II Up to 2000 A P 2 8 Bottom: connecting flange Up to 2500 A P 2 8 Up to 3200 A P 2 8 III Up to 4000 A P 2 8 Siemens LV 0 206/207 /49

50 3WL /Non-Automatic Options Add "-Z" to the complete Article No. and indicate the appropriate order @ Additional price For fixed-mounted circuit breakers Note To select this connection method, the 2th digit of the Article No. for the circuit breaker must be a "2". Additional price 3-pole Additional price 4-pole Connection methods for main connections Rated current I n Top: ) I Up to 600 A N horizontal II Up to 2000 A N Bottom: accessible from front, Up to 2500 A N single hole Up to 3200 A N Additional price ) Not for 3WL size I with high breaking capacity H and circuit breakers with very high breaking capacity C. 2) Not for size III with very high breaking capacity C III 2) Up to 4000 A N Connection methods for main connections Rated current I n Top: I Up to 600 A N 2 0 vertical Up to 2000 A N 2 0 Bottom: horizontal II Up to 2000 A N 2 0 Up to 2500 A N 2 0 Up to 3200 A N 2 0 III Up to 4000 A N 2 0 Up to 5000 A N 2 0 Connection methods for main connections Rated current I n Top: I Up to 600 A N 2 4 horizontal Up to 2000 A N 2 4 Bottom: vertical II Up to 2000 A N 2 4 Up to 2500 A N 2 4 Up to 3200 A N 2 4 III Up to 4000 A N 2 4 Up to 5000 A N 2 4 /50 Siemens LV 0 206/207

51 3WL /Non-Automatic Overview Determination of the number of auxiliary supply connectors required This selection is only required if the guide frame is ordered under a separate Article No. NSE0_004 X8 X7 X6 X5 Accessories and spare parts The required number of auxiliary supply connectors depends on the: Operating mechanism type Electronic Trip Unit with/without current transformer Type and number of auxiliary releases Number of auxiliary switches COM5/COM6 communication interface Number of auxiliary supply connectors a The first auxiliary supply connector X6 is always required. X6 b b b2 b3 c c c2 c3 c4 d d d2 e e e2 f f f2 g g g2 g3 g4 g5 g6 g7 g8 Operating mechanisms Manual operating mechanism with stored-energy feature with mechanical closing Manual operating mechanism with stored-energy feature with mechanical and electrical closing Manual/motorized operating mechanism with stored-energy feature with mechanical and electrical closing Electronic Trip Units Electronic Trip Units ETU5B, ETU25B, ETU27B Electronic Trip Units ETU45B, ETU76B (internal CubicleBUS) Connections for external current transformers for overload protection in the N conductor and ground-fault protection Current transformer installed in the N conductor (required with 3-pole circuit breakers if c2 is not selected) Current transformer in the neutral point of the transformer (required if c2 or c3 is not selected) Auxiliary releases With/without st auxiliary release (shunt release F) 2nd auxiliary release (shunt release F2, undervoltage release F3, delayable undervoltage release F4) Auxiliary switch blocks st auxiliary switch block 2 NO + 2 NC st and 2nd auxiliary switch block 4 NO + 4 NC or 6 NO + 2 NC or 5 NO + 3 NC (required if b3 or d2 is not selected) Communication modules Without communication module COM5/COM6 With communication module COM5/COM6 occupies the entire terminal strip X7, making the following options no longer possible: Tripped signal switch S24 Stored-energy status indication S2 Electrical ON button S0 Signaling switch on first and second auxiliary release S22 + S23 Optional signals/accessories Tripped signaling switch S24 (only when f2 not selected) Stored-energy status indicator S2 (only when f2 not selected, required if g not selected) Electric ON button S0 (only when f2 not selected, required if g or g2 not selected) Signaling switch at first auxiliary release S22 (only when f2 not selected, required if g, g2 or g3 not selected) Signaling switch at second auxiliary release S23 (only when f2 not selected, required if g, g2, g3 or g4 not selected) Switch on ready-to-close signaling switch S20 Motor shutdown switch S2 (only if motorized operating mechanism selected) Remote reset solenoid F7 (required if c2 not selected) h Total number of auxiliary supply connectors (max. 4) For ordering the auxiliary supply connectors, see under "Accessories and spare parts, Guide frames for AC circuit breakers/ non-automatic air circuit breakers", page /52 to page /57 and under "Accessories and spare parts, Auxiliary conductor connections, Auxiliary supply connectors", page / Terminal X6 X5 X8 X8 X8 X6 X5 X6 X5 0 + X X7 X7 X7 X7 X7 X6 X5 X8 Siemens LV 0 206/207 /5

52 3WL /Non-Automatic Accessories and spare parts Selection and ordering data Guide frames for AC circuit breakers/non-automatic air circuit breakers Max. rated circuit breaker current I n max. Breaking capacity I cu = I cs Additional price ) For 3WL air circuit breakers size I from 630 A to 2000 A with high breaking capacity H and 3WL air circuit breakers size I with rated current I n = 2000 A. DT Guide frames for 3-pole circuit breakers/ non-automatic air circuit breakers Article No. Basic price SET, M) A ka Front main circuit connection, single hole I WL92-AA@@-@@A unit CA WL92-2AA@@-@@A unit CA II WL922-3AA@@-@@A unit CA WL922-4AA@@-@@A unit CA WL922-5AA@@-@@A unit CA III WL923-6AA@@-@@A unit CA Front main circuit connection, double hole I WL92-AB@@-@@A unit CA WL92-2AB@@-@@A unit CA ) WL92-3AB@@-@@A unit CA II WL922-3AB@@-@@A unit CA WL922-4AB@@-@@A unit CA WL922-5AB@@-@@A unit CA III WL923-6AB@@-@@A unit CA Horizontal main circuit connection I WL92-AC@@-@@A unit CA WL92-2AC@@-@@A unit CA ) WL92-3AC@@-@@A unit CA II WL922-3AC@@-@@A unit CA WL922-4AC@@-@@A unit CA WL922-5AC@@-@@A unit CA WL922-5AC@@-@@C unit CA III WL923-6AC@@-@@A unit CA WL923-7AC@@-@@A unit CA WL923-6AC@@-@@C unit CA WL923-7AC@@-@@C unit CA Options Additional price Number of auxiliary supply connectors Note For required number of auxiliary supply connectors, see table on page /5. Type of auxiliary circuit connections None 0 None connector 2 connectors 2 3 connectors 3 4 connectors 4 None 0 None With screw connection (SI- GUT, standard) With screwless connection method (tension spring) 2 Position signaling switches None 0 None Option : Connected position CO, test position CO, disconnected position CO Option 2: Connected position 3 CO, test position 2 CO, disconnected position CO 2 Shutters None A None With shutter, 2-part, lockable I B II B III B /52 Siemens LV 0 206/207

53 3WL /Non-Automatic Add "-Z" to the complete Article No. and indicate the appropriate order code(s). Accessories and spare parts 3WL Z @ Rated voltage 000 V AC and 690 V IT networks I (breaking capacity H) A 0 5 II, except breaking capacity C and 4000 A (breaking capacity H) A 0 5 III, not necessary with circuit breakers with very high breaking capacity A 0 5 Rated voltage 50 V AC II, except breaking capacity C and 4000 A (breaking capacity H) A 5 Rated voltage 690 V AC (+ 20 %) I (breaking capacity H) A 6 Tinned version of the customer's connections on guide frame )2) Only for guide frames with horizontal connection or flange connection I A 0 8 II A 0 8 III A 0 8 Notes For main circuit connection vertical and main circuit connecting flange, see the following page. All other accessory parts must be ordered by specifying "-Z" and the corresponding order code, see page /45 to page /50. Additional price ) Front connections are tinned as standard. 2) The permissible temperature-rise limits according to IEC are 5 K lower for a tin surface than for a silver surface. Siemens LV 0 206/207 /53

54 3WL /Non-Automatic Accessories and spare parts Max. rated circuit breaker current I n max. Breaking capacity DT Guide frames for 3-pole circuit breakers/ I cu = I cs non-automatic air circuit breakers SET, M) Article No.: Basic price A ka Vertical main circuit connection I WL92-AD@@-@@A unit CA WL92-2AD@@-@@A unit CA ) WL92-3AD@@-@@A unit CA II WL922-3AD@@-@@A unit CA WL922-4AD@@-@@A unit CA WL922-5AD@@-@@A unit CA WL922-5AD@@-@@C unit CA WL922-6AD@@-@@A unit CA III WL923-6AD@@-@@A unit CA WL923-7AD@@-@@A unit CA WL923-8AD@@-@@A unit CA WL923-6AD@@-@@C unit CA WL923-7AD@@-@@C unit CA WL923-8AD@@-@@C unit CA Main circuit connection connecting flanges I WL92-AE@@-@@A unit CA WL92-2AE@@-@@A unit CA ) WL92-3AE@@-@@A unit CA II WL922-3AE@@-@@A unit CA WL922-4AE@@-@@A unit CA WL922-5AE@@-@@A unit CA III WL923-6AE@@-@@A unit CA Options Number of auxiliary supply connectors Note Additional price None 0 None connector 2 connectors 2 3 connectors 3 4 connectors 4 For required number of auxiliary supply connectors, see table on page /5. Type of auxiliary circuit connections Position signaling switches None 0 None With screw connection (SIGUT, standard) With screwless connection method (tension spring) 2 None 0 None Option : Connected position CO, test position CO, disconnected position CO Option 2: Connected position 3 CO, test position 2 CO, disconnected position CO 2 Shutters None A None With shutter, I B 2-part, II B lockable III B Rated voltage 000 V AC and 690 V IT networks Additional price ) For 3WL circuit breakers size I from 630 A to 2000 A with high breaking capacity H and 3WL circuit breakers size I with rated current I n = 2000 A. Add "-Z" to the complete Article No. and indicate the appropriate order code(s). 3WL Z Additional price I (breaking capacity H) A 0 5 II, except breaking capacity C and 4000 A (breaking capacity H) A 0 5 III, not necessary with circuit breakers with very high breaking capacity A 0 5 Rated voltage 50 V AC II, except breaking capacity C and 4000 A (breaking capacity H) A 5 Rated voltage 690 V AC (+ 20 %) I (breaking capacity H) A 6 Tinned version of the customer's connections on guide frame )2) Only for guide frames with horizontal connection or flange connection I A 0 8 II A 0 8 III A 0 8 Notes For main circuit connection vertical and main circuit connecting flange, see the following page. All other accessory parts must be ordered by specifying "-Z" and the corresponding order code, see page /45 to @ 2) Front connections are tinned as standard. 3) The permissible temperature-rise limits according to IEC are 5 K lower for a tin surface than for a silver surface. /54 Siemens LV 0 206/207

55 3WL /Non-Automatic Max. rated circuit breaker current I n max. Breaking capacity I cu = I cs DT Guide frames for 4-pole circuit breakers/ non-automatic air circuit breakers Accessories and spare parts SET, M) Article No. Basic price A ka Front main circuit connection, single hole I WL92-BA@@-@@A unit CA WL92-2BA@@-@@A unit CA II WL922-3BA@@-@@A unit CA WL922-4BA@@-@@A unit CA WL922-5BA@@-@@A unit CA III WL923-6BA@@-@@A unit CA Front main circuit connection, double hole I WL92-BB@@-@@A unit CA WL92-2BB@@-@@A unit CA ) WL92-3BB@@-@@A unit CA II WL922-3BB@@-@@A unit CA WL922-4BB@@-@@A unit CA WL922-5BB@@-@@A unit CA III WL923-6BB@@-@@A unit CA Horizontal main circuit connection I WL92-BC@@-@@A unit CA WL92-2BC@@-@@A unit CA ) WL92-3BC@@-@@A unit CA II WL922-3BC@@-@@A unit CA WL922-4BC@@-@@A unit CA WL922-5BC@@-@@A unit CA WL922-5BC@@-@@C unit CA III WL923-6BC@@-@@A unit CA WL923-7BC@@-@@A unit CA WL923-6BC@@-@@C unit CA WL923-7BC@@-@@C unit CA Options Additional price Number of auxiliary supply connectors Note For required number of auxiliary supply connectors, see table on page /5. Type of auxiliary circuit connections None 0 None connector 2 connectors 2 3 connectors 3 4 connectors 4 None 0 None With screw connection (SI- GUT, standard) With screwless connection method (tension spring) 2 Position signaling switches None 0 None Option : Connected position CO, test position CO, disconnected position CO Option 2: Connected position 3 CO, test position 2 CO, disconnected position CO 2 Shutters None A None With shutter, 2-part, lockable I B II B III B Additional price ) For 3WL circuit breakers size I from 630 A to 2000 A with high breaking capacity H and 3WL circuit breakers size I with rated current I n = 2000 A. Siemens LV 0 206/207 /55

56 3WL /Non-Automatic Accessories and spare parts Add "-Z" to the complete Article No. and indicate the appropriate order @ Additional price Rated voltage 000 V AC and 690 V IT networks I (breaking capacity H) A 0 5 II, except breaking capacity C and 4000 A (breaking capacity H) A 0 5 III, not necessary with circuit breakers with very high breaking capacity A 0 5 Rated voltage 50 V AC II, except breaking capacity C and 4000 A (breaking capacity H) A 5 Rated voltage 690 V AC (+ 20 %) I (breaking capacity H) A 6 Tinned version of the customer's connections on guide frame )2) Only for guide frames with horizontal connection or flange connection I A 0 8 II A 0 8 III A 0 8 Notes For main circuit connection vertical and main circuit connecting flange, see the following page. All other accessory parts must be ordered by specifying "-Z" and the corresponding order code, see page /45 to page /50. Additional price ) Front connections are tinned as standard. 2) The permissible temperature-rise limits according to IEC are 5 K lower for a tin surface than for a silver surface. /56 Siemens LV 0 206/207

57 3WL /Non-Automatic Accessories and spare parts Max. rated circuit breaker current Breaking capacity I cu = I cs DT Guide frames for 4-pole circuit breakers/ non-automatic air circuit breakers I n max. Article No.: Basic price SET, A ka M) Vertical main circuit connection I WL92-BD@@-@@A unit CA WL92-2BD@@-@@A unit CA ) WL92-3BD@@-@@A unit CA II WL922-3BD@@-@@A unit CA WL922-4BD@@-@@A unit CA WL922-5BD@@-@@A unit CA WL922-5BD@@-@@C unit CA WL922-6BD@@-@@A unit CA III WL923-6BD@@-@@A unit CA WL923-7BD@@-@@A unit CA WL923-8BD@@-@@A unit CA WL923-6BD@@-@@C unit CA WL923-7BD@@-@@C unit CA WL923-8BD@@-@@C unit CA Main circuit connection connecting flanges I WL92-BE@@-@@A unit CA WL92-2BE@@-@@A unit CA ) WL92-3BE@@-@@A unit CA II WL922-3BE@@-@@A unit CA WL922-4BE@@-@@A unit CA WL922-5BE@@-@@A unit CA III WL923-6BE@@-@@A unit CA Options Number of auxiliary supply connectors Note Additional price None 0 None connector 2 connectors 2 3 connectors 3 4 connectors 4 For required number of auxiliary supply connectors, see table on page /5. Type of auxiliary circuit connections Position signaling switches None 0 None With screw connection (SIGUT, standard) With screwless connection method (tension spring) 2 None 0 None Option : Connected position CO, test position CO, disconnected position CO Option 2: Connected position 3 CO, test position 2 CO, disconnected position CO 2 Shutters None A None With shutter, 2-part, lockable I B II B III B Add "-Z" to the complete Article No. and indicate the appropriate order @ Additional price Rated voltage 000 V AC and 690 V IT networks I (breaking capacity H) A 0 5 II, except breaking capacity C and 4000 A (breaking capacity H) A 0 5 III, not necessary with circuit breakers with very high breaking capacity A 0 5 Rated voltage 50 V AC II, except breaking capacity C and 4000 A (breaking capacity H) A 5 Rated voltage 690 V AC (+ 20 %) I (breaking capacity H) A 6 Tinned version of the customer's connections on guide frame )2) Only for guide frames with horizontal connection or flange connection I A 0 8 II A 0 8 III A 0 8 Notes For main circuit connection vertical and main circuit connecting flange, see the following page. All other accessory parts must be ordered by specifying "-Z" and the corresponding order code, see page /45 to page /50. Additional price ) For 3WL circuit breakers size I from 630 A to 2000 A with high breaking capacity H and 3WL circuit breakers size I with rated current I n = 2000 A. 2) Front connections are tinned as standard. 3) The permissible temperature-rise limits according to IEC are 5 K lower for a tin surface than for a silver surface. Siemens LV 0 206/207 /57

58 3WL /Non-Automatic Accessories and spare parts NSE0_060b 3WL93.-.AA.0-0AA NSE0_00992b 3WL9-0AA64-0AA0 NSE0_0027a 3WL9-0AT53-0AA0 Designation Protective devices with device holder and optional measurement function ) Type With protection function Measuring function DT Article No. Price SET, M) ETU5B LI None 3WL93-5AA00-0AA2 unit CA ETU25B LSI None 3WL932-5AA00-0AA2 unit CA ETU27B LSING None 3WL932-7AA00-0AA2 unit CA ETU45B LSIN(G) None 3WL934-5AA00-0AA2 unit CA (without display) With measurement 3WL934-5AA20-0AA2 unit CA function Plus ETU76B LSIN(G) None 3WL937-6AA00-0AA2 unit CA With measurement 3WL937-6AA20-0AA2 unit CA function Plus Rating plugs 2) Rated current I n (A) I, II 250 3WL9-0AA5-0AA0 unit CA WL9-0AA52-0AA0 unit CA WL9-0AA53-0AA0 unit CA WL9-0AA54-0AA0 unit CA WL9-0AA55-0AA0 unit CA WL9-0AA56-0AA0 unit CA WL9-0AA57-0AA0 unit CA 0.00 I, II, III 250 3WL9-0AA58-0AA0 unit CA WL9-0AA6-0AA0 unit CA WL9-0AA62-0AA0 unit CA 0.00 II, III WL9-0AA63-0AA0 unit CA WL9-0AA64-0AA0 unit CA WL9-0AA65-0AA0 unit CA 0.00 III WL9-0AA66-0AA0 unit CA WL9-0AA67-0AA0 unit CA 0.00 Ground-fault modules 3) Versions GFM AT 45B (only for ETU45B) alarm and tripping 3WL9-0AT53-0AA0 unit CA GFM AT 55B 76B (only for ETU76B) alarm and tripping 3WL9-0AT56-0AA0 unit CA Displays 3WL9-0AT8-0AA0 unit CA For ETU45B 4-line NSE0_0609 3WL9-0AT8-0AA0 NSE0_00990a 3WL9-0AA2.-0AA0 NSE0_0099a 3WL9-0AA3.-0AA0 ) For replacement in existing circuit breakers please specify the circuit breaker ID No. when ordering. 2) With the rating plug selected, the maximum rated current I n max of the circuit breaker must not be exceeded. The following applies I n I n max. /58 Siemens LV 0 206/207 Internal current transformers for N conductor Including wiring kit ETU Release 2 I 3WL9-0AA-0AA0 unit CA II 3WL9-0AA2-0AA0 unit CA III 3WL9-0AA3-0AA0 unit CA I 3WL9-0AA4-0AA0 unit CA II 3WL9-0AA5-0AA0 unit CA III 3WL9-0AA6-0AA0 unit CA External current transformers for N conductor For T5, "Measurement Method" function, see Technical Information at lowvoltage/product-support. Copper connection pieces I 3WL9-0AA2-0AA0 unit CA II 3WL9-0AA22-0AA0 unit CA III 3WL9-0AA23-0AA0 unit CA I 3WL9-0AA3-0AA0 unit CA.600 II 3WL9-0AA32-0AA0 unit CA III 3WL9-0AA33-0AA0 unit CA EMC filters Common-mode interference suppressor filters (e.g. in IT networks, caused by frequency converters) Insertion loss (asymmetric) in the range 40 khz to 0 MHz >40 db. Versions Not for ETU Release 2 3WL9-0AK32-0AA0 unit CA Only for ETU Release 2 3WL9-0AK34-0AA0 unit CA ) For direct measurement of the ground-fault current, e.g. in the neutral point of the transformer, a 200 A/ A current transformer, class, is required. The internal load of the 3WL circuit breaker is 0. m. If the ground-fault current is to be determined using the vectorial sum of the phases, a transformer must be installed in the neutral conductor.

59 3WL /Non-Automatic Designation More accessories for Electronic Trip Units ETU25B NSE0_00983b 3WL9-0AT45-0AA0 NSE0_00999a 3WL9-0AK0.-0AA0 Locking devices Sealable and lockable covers Versions DT Article No. Accessories and spare parts Price SET, M) For ETU5B to ETU45B 3WL9-0AT45-0AA0 unit CA For ETU76 3WL9-0AT46-0AA0 unit CA Automatic reset of the reclosing lockout Spare part for option K0, for "-Z" + order code, see page /46. Remote reset coils ) For mechanical tripped indicator Spare part for options K0 to K3, for "-Z" + order code, see page /46. Note Automatic reset of the reclosing lockout 3WL9-0AK2-0AA0 also needed. Versions 3WL9-0AK2-0AA0 unit CA V DC 3WL9-0AK03-0AA0 unit CA V DC 3WL9-0AK04-0AA0 unit CA V AC/25 V DC 3WL9-0AK05-0AA0 unit CA V AC/ V DC 3WL9-0AK06-0AA0 unit CA Retrofittable internal CubicleBUS wiring for connection to terminal X8 For ETU45B and ETU76B Without male connector 2) Retrofittable internal wiring for connection of the external N- and G-transformers to terminal X8 Not for ETU Release 2 Without male connector Retrofittable internal wiring for connection of the external N- and G-transformers to terminal X8 For ETU Release 2 Without male connector Interlocking set for mechanical ON/OFF Consisting of 2 transparent covers each for sealing or for attaching padlocks 4), Cover with 6.35 mm hole (for tool actuation) Lock mount for safety lock for key operation 3WL9-0AK30-0AA0 unit CA WL9-0AK3-0AA0 unit CA WL9-0AK33-0AA0 unit CA NSE0_ WL9-0BA22-0AA0 3WL9-0BA3-0AA0 NSE0_00982 NSE WL9-0BA53-0AA0 Versions Without safety lock 3WL9-0BA2-0AA0 unit CA 0.00 Made by CES 3WL9-0BA22-0AA0 unit CA Made by IKON 3WL9-0BA24-0AA0 unit CA Locking devices against unauthorized closing, in the operator panels The disconnector unit fulfills the requirements for main circuit breakers acc. to EN Spare part for options S0 to S09, for "-Z" + order code, see page /48. Versions Assembly kit FORTRESS or CASTELL 3) 3WL9-0BA3-0AA0 unit CA Made by Ronis 3WL9-0BA33-0AA0 unit CA Made by KIRK-Key 3) 3WL9-0BA34-0AA0 unit CA Made by Profalux 3WL9-0BA35-0AA0 unit CA Made by CES 3WL9-0BA36-0AA0 unit CA Made by IKON 3WL9-0BA38-0AA0 unit CA Assembly kit for padlocks 4) 3WL9-0BA4-0AA0 unit CA Locking devices against unauthorized closing, for withdrawable circuit breakers The disconnector unit fulfills the requirements for main circuit breakers acc. to EN Consisting of lock in the cabinet door, active in connected position; function is retained when circuit breaker is replaced Spare part for options R60, R6, R68, for "-Z" + order code, see page /48. Versions Made by CES 3WL9-0BA5-0AA0 unit CA Made by IKON 3WL9-0BA53-0AA0 unit CA Made by KIRK-Key 3) 3WL9-0BA57-0AA0 unit CA Made by Ronis 3WL9-0BA58-0AA0 unit CA Made by Profalux 3WL9-0BA50-0AA0 unit CA ) Can only be used in conjunction with "automatic reset of reclosing lockout", e.g. "-Z" + "K0", 3WL9-0AK2-0AA0. 2) Required if communication is retrofitted. 3) Locks, cylinders and keys must be ordered from the manufacturer. 4) Padlock not included in the scope of supply. Siemens LV 0 206/207 /59

60 3WL /Non-Automatic Accessories and spare parts Designation Locking devices for operating mechanism handle with padlock ) Spare part for option S33, for "-Z" + order code, see page /48. DT Article No. Price SET, M) 3WL9-0BA7-0AA0 unit CA NSE0_ WL9-0BA7-0AA0 NSE0_ WL9-0BA76-0AA0 Locking devices to prevent movement of the withdrawable circuit breakers Safety lock for mounting on the circuit breaker Spare part for options S7, S75, S76, for "-Z" + order code, see page /48. Versions Made by CES 3WL9-0BA73-0AA0 unit CA Made by IKON 3WL9-0BA75-0AA0 unit CA Made by Profalux 3WL9-0BA76-0AA0 unit CA Made by Ronis 3WL9-0BA77-0AA0 unit CA Made by KIRK-Key 2) 3WL9-0BA80-0AA0 unit CA Interlocking systems Made by CES 2 of the same keys for 3 circuit breakers Locking device in OFF position Lock in the operator panel A maximum of 2 circuit breakers can be switched on Locking mechanisms Locking devices to prevent movement of the withdrawable circuit breakers in disconnected position Consisting of Bowden wire and lock in the cabinet door on the circuit breaker NSE0_00987 Spare part for options R8, R85, R86, for "-Z" + order 3WL9-0BA83-0AA0 code, see page /48. Versions NSE0_ WL9-0BB2-0AA0 ) Padlock not included in the scope of supply. 2) Locks, cylinders and keys must be ordered from the manufacturer. 3WL9-0BA43-0AA0 unit CA Made by CES 3WL9-0BA8-0AA0 unit CA Made by IKON 3WL9-0BA83-0AA0 unit CA Made by Profalux 3WL9-0BA85-0AA0 unit CA Made by Ronis 3WL9-0BA86-0AA0 unit CA Note Not possible in combination with "Locking device to prevent opening of the cabinet door" (order code "R30") or "Locking device to prevent movement with the cabinet door open" (order code "R50"). Locking devices to prevent opening of the cabinet door in ON position Fixed-mounted Can be defeated Spare part for option S30, for "-Z" + order code, see page /48. 3WL9-0BB2-0AA0 unit CA Locking devices to prevent opening of the cabinet door 3WL9-0BB3-0AA0 unit CA 0.50 Guide frames Can be defeated Spare part for option R30, for "-Z" + order code, see page /48. Note Not possible in combination with "Locking device to prevent movement of the withdrawable circuit breakers in disconnected position" (order codes "R8", "R85" or "R86"). Locking devices to prevent movement with the cabinet door open Guide frames Spare part for option R50, for "-Z" + order code, see page /48. Note Not possible in combination with "Locking device to prevent movement of the withdrawable circuit breakers in disconnected position" (order codes "R8", "R85" or "R86"). 3WL9-0BB5-0AA0 unit CA 0.50 /60 Siemens LV 0 206/207

61 Interlocks NSE0_ WL9-0BB2-0AA0 Designation Mutual mechanical interlocking with 2000 mm Bowden wire (one required for each circuit breaker) Type Fixed-mounted circuit breakers Module for withdrawable circuit breakers with guide frame When ordered separately 3WL /Non-Automatic Spare part for Option S55, for "-Z" + order code, see page /47. Option R55, for "-Z" + order code, see page /47. Module for guide frame Option R56, for "-Z" + order code, see page /47. Module for withdrawable circuit breaker Adapter for size III withdrawable circuit breaker Siemens AG 206 Option R57, for "-Z" + order code, see page /47. Couplings on the circuit breaker (with ring) for mutual interlocking Can be used in all circuit breakers DT Article No. Accessories and spare parts Price SET, M) 3WL9-0BB2-0AA0 unit CA WL9-0BB24-0AA0 unit CA.30 3WL9-0BB22-0AA0 unit CA.00 3WL9-0BB23-0AA0 unit CA WL9-0BB30-0AA0 unit CA WL92-8AH47-0AA0 unit CA 0.60 NSE0_0886 3WL92-8HA47-0AA0 Bowden wires Versions 2000 mm 3WL9-0BB45-0AA0 unit CA mm 3WL9-0BB46-0AA0 unit CA mm 3WL9-0BB47-0AA0 unit CA Transfer control devices 3KC ATC5300 and ATC300 transfer control devices For combination with two air circuit breakers/molded case circuit breakers for changeover according to IEC For further information, see Chapter "Monitoring Devices". 3KC9000-8TL30 3KC9000-8EL0 Test devices Manual tester Release 2 for Electronic Trip Units ETU5B to ETU76B For testing the Electronic Trip Unit functions of all 3WL ETUs (release and release 2) 3WL9-0AT32-0AA0 unit CA.00 Function testers 3WL9-0AT44-0AA0 unit CA 8.20 For testing the tripping characteristics for Electronic Trip Units ETU5B to ETU76B Capacitor storage devices Capacitor storage devices 3WL9-0BA4-0AA0 unit CA For shunt releases Storage time 5 min Rated control supply voltage/rated operational voltage 50/60 Hz V AC V DC Note Rated control supply voltage must match the rated control supply voltage of the shunt release Suitable also for 3VL and 3WN circuit breakers Siemens LV 0 206/207 /6

62 NSE0_00985 Siemens AG 206 3WL /Non-Automatic Accessories and spare parts Designation Indicators, control elements DT Article No. Price SET, M) Ready-to-close signaling switches (S20) 3WL9-0AH0-0AA0 unit CA NO contact Spare part for option C22, for "-Z" + order code, see page /46. NSE0_00993a 3WL9-0AH0-0AA0 NSE0_00994b Signaling switches )2) (S22 or S23) 3WL9-0AH02-0AA0 unit CA st or 2nd auxiliary release Spare part for options C26 and C27, for "-Z" + order code, see page /46. 3WL9-0AH02-0AA0 st tripped signaling switch )2) (S24) 3WL9-0AH4-0AA0 unit CA CO contact Spare part for option K07, for "-Z" + order code, see page /46. 2nd tripped signaling switch )2)3) (S25) 3WL9-0AH7-0AA0 unit CA NO contact Spare part for option K06, for "-Z" + order code, see page /46. Operating cycles counter 3WL9-0AH07-0AA0 unit CA 0.00 Mechanical 4) Spare part for option C0, for "-Z" + order code, see page /46. NSE0_00995a 3WL9-0AH07-0AA0 NSE0_00996a 3WL9-0AH2-0AA0 NSE0_00997a 3WL9-0AJ0.-0AA0 Stored energy status signaling switches )2) 3WL9-0AH08-0AA0 unit CA NO contact Spare part for option C20, for "-Z" + order code, see page /46. Position signaling switches for guide frames Spare part for options R5 and R6, for "-Z" + order code, see page /47. Versions. block (3 CO contacts) 3WL9-0AH-0AA0 unit CA block (6 CO contacts) 3WL9-0AH2-0AA0 unit CA Electrical ON buttons )5) (S0) Button + wiring 2) For operator panel Spare part for options C and C2, for "-Z" + order code, see page /46. Versions With sealing cap C 3WL9-0AJ02-0AA0 unit CA 0.50 With CES C2 assembly kit 3WL9-0AJ03-0AA0 unit CA 0.40 With IKON assembly kit 3WL9-0AJ05-0AA0 unit CA 0.40 Note Possible only for circuit breakers with closing coil. Motor shutdown switches 6) (S2) 3WL9-0AJ06-0AA0 unit CA 0.00 Mounting on operator panel Spare part for option S25, for "-Z" + order code, see page /46. EMERGENCY-STOP pushbuttons 3WL9-0BA72-0AA0 unit CA Mushroom pushbutton instead of the mechanical OFF pushbutton Spare part for option S24, for "-Z" + order code, see page /46. 3WL9-0BA72-0AA0 ) Not possible with communications interface option, order codes "F02" or "F2". 2) X7 auxiliary supply connector required for circuit breakers or guide frames. If this is not already available, please order additionally (see page /5 and page /63). 3) Can only be used in combination with st tripped signaling switch. 4) Only in conjunction with motorized operating mechanism. 5) Not possible with motor shutdown switch. 6) Not possible with electrical ON button. /62 Siemens LV 0 206/207

63 3WL /Non-Automatic Designation Auxiliary conductor connections DT Article No. Price Accessories and spare parts SET, M) Male connectors for circuit breakers $ 3WL9-0AB0-0AA0 unit CA WL9-0AB0-0AA0 Extension for the 000 V male connector 3WL9-0AB02-0AA0 unit EA 0.50 versions Male connector must be ordered separately. Male connectors and extension for 000 V 3WL9-0AB0-0AA0 unit EA.000 NSE0_0268 Auxiliary supply connectors for circuit breakers or guide frames % Versions Screw connection (SIGUT) 3WL9-0AB03-0AA0 unit CA Screwless connection method (tension spring) 3WL9-0AB04-0AA0 unit CA WL9-0AB03-0AA0 3WL9-0AB04-0AA0 Coding kits 3WL9-0AB07-0AA0 unit CA For fixed-mounted versions (X5 to X8) & NSE0_00974 NSE0_0269 NSE0_ WL9-0AB07-0AA0 Sliding contact modules for guide frames ( 3WL9-0AB08-0AA0 unit CA 0.00 NSE0_00977a 3WL9-0AB08-0AA0 NSE0_0586 One-part sliding contact modules for guide frames Screw connection (SIGUT)) 3WL9-0AB8-0AA0 unit CA WL9-0AB8-0AA0 Blanking blocks for circuit breakers 3WL9-0AB2-0AA0 unit CA For a complete auxiliary current connection you must order: Fixed-mounted version: $ + % + & Withdrawable version: $ + ( + % or $ + ) Siemens LV 0 206/207 /63

64 3WL /Non-Automatic Accessories and spare parts Auxiliary releases NSE0_0000 3WL9-0AD06-0AA0 NSE0_000 3WL9-0AE0.-0AA0 Designation Closing coils/shunt releases Versions Voltage DT Article No. Price SET, M) 00 % OP 24 V DC 3WL9-0AD0-0AA0 unit CA V DC 3WL9-0AD02-0AA0 unit CA V DC 3WL9-0AD03-0AA0 unit CA V DC 3WL9-0AD04-0AA0 unit CA V DC/ V AC 3WL9-0AD05-0AA0 unit CA V DC/ V AC 3WL9-0AD06-0AA0 unit CA % OP ) 24 V DC 3WL9-0AD-0AA0 unit CA V DC 3WL9-0AD2-0AA0 unit CA V DC/ V AC 3WL9-0AD3-0AA0 unit CA V DC/ V AC 3WL9-0AD4-0AA0 unit CA.800 Undervoltage releases Versions Voltage Instantaneous 24 V DC 3WL9-0AE0-0AA0 unit CA V DC 3WL9-0AE02-0AA0 unit CA V DC 3WL9-0AE03-0AA0 unit CA V DC 3WL9-0AE07-0AA0 unit CA V DC/ V AC 3WL9-0AE04-0AA0 unit CA V DC/ V AC 3WL9-0AE05-0AA0 unit CA V AC 3WL9-0AE06-0AA0 unit CA Delayed 48 V DC 3WL9-0AE-0AA0 unit CA V DC/ V AC 3WL9-0AE2-0AA0 unit CA V DC/ V AC 3WL9-0AE3-0AA0 unit CA V AC 3WL9-0AE4-0AA0 unit CA NSE0_0002 3WL9-0AE.-0AA0 Operating mechanisms Motorized operating mechanisms 2) Versions V DC 3WL9-0AF0-0AA0 unit CA V DC 3WL9-0AF02-0AA0 unit CA V DC/ V AC 3WL9-0AF03-0AA0 unit CA V DC/ V AC 3WL9-0AF04-0AA0 unit CA.50 NSE0_0003a 3WL9-0AF0.-0AA0 Auxiliary contacts NSE0_0004 Auxiliary switch blocks Versions 2 NO contacts + 2 NC contacts 3WL9-0AG0-0AA0 unit CA NO contacts 3WL9-0AG02-0AA0 unit CA NO contact + NC contact 3WL9-0AG03-0AA0 unit CA WL9-0AG03-0AA0 ) Overexcited, i.e. operating time 50 ms (standard > 80 ms). 2) X5 auxiliary supply connector required for circuit breakers or guide frames. If this is not already available, please order additionally (see page /5 and page /54). /64 Siemens LV 0 206/207

65 3WL /Non-Automatic Designation Door sealing frames, hoods, shutters DT Article No. Price Accessories and spare parts SET, M) Door sealing frames 3WL9-0AP0-0AA0 unit CA Spare part for option T40, for "-Z" + order code, see page /46. Protective covers 3WL9-0AP02-0AA0 unit CA.600 IP55 Notes Cannot be used in conjunction with door sealing frames Hood removable and can be opened on both sides NSE0_0028a 3WL9-0AP02-0AA0 NSE0_0006 3WL9-0AP0.-0AA0 Arc chutes 3WL9-0AS0.-0AA0 NSE0_0007 Shutters Spare part for option R2, for "-Z" + order code, see page /47. Number of poles 3-pole I 3WL9-0AP04-0AA0 unit CA II ) 3WL9-0AP06-0AA0 unit CA II C 3WL9-0AP43-0AA0 unit CA III 3WL9-0AP07-0AA0 unit CA pole I 3WL9-0AP08-0AA0 unit CA II ) 3WL9-0AP-0AA0 unit CA II C 3WL9-0AP44-0AA0 unit CA III 3WL9-0AP2-0AA0 unit CA.070 Arc chutes Versions 690 V I 3WL9-0AS0-0AA0 unit CA.0 II ) 3WL9-0AS02-0AA0 unit CA.680 II C 3WL9-0AS0-0AA0 unit CA III 3WL9-0AS03-0AA0 unit CA V/50 V II 3WL9-0AS05-0AA0 unit CA 3.40 III 3WL9-0AS06-0AA0 unit CA NSE0_0008 3WL9-0AS3.-0AA0 ) Cannot be used for 3WL size II with very high breaking capacity C 2) Not available for V version (order code "A05") - 50 V version (order code "A5") - DC version A size II - circuit breaker with very high breaking capacity C Arc chute covers 2) Parts kit for guide frame Spare part for option R0, for "-Z" + order code, see page /47. Number of poles 3-pole I 3WL9-0AS32-0AA0 unit CA.850 II 3WL9-0AS36-0AA0 unit CA III 3WL9-0AS38-0AA0 unit CA pole I 3WL9-0AS42-0AA0 unit CA II 3WL9-0AS44-0AA0 unit CA III 3WL9-0AS46-0AA0 unit CA 5.20 Coding for withdrawable version NSE0_0009 3WL9-0AR2-0AA0 3WL9-0AR3-0AA0 Coding for withdrawable version By customer, for 36 coding variants Versions s I and II 3WL9-0AR2-0AA0 unit CA III 3WL9-0AR3-0AA0 unit CA 0.30 Siemens LV 0 206/207 /65

66 3WL /Non-Automatic Accessories and spare parts Grounding connection NSE0_008a 3WL9-0BA02-0AA0 3WL9-0BA07-0AA0 Support brackets NSE0_0022 NSE0_009 Designation DT Article No. Grounding connection between the guide frame and the withdrawable circuit breaker For 30 ka ground short-circuit current ) Contacting modules for guide frame Versions Price SET, M) I and II 2) 3WL9-0BA0-0AA0 unit CA III 3WL9-0BA02-0AA0 unit CA Contacting modules for withdrawable circuit breakers Number of poles 3-pole I 3WL9-0BA05-0AA0 unit CA.250 II 2) 3WL9-0BA06-0AA0 unit CA.530 III 3WL9-0BA07-0AA0 unit CA pole I 3WL9-0BA08-0AA0 unit CA.500 II 2) 3WL9-0BA04-0AA0 unit CA.850 III 3WL9-0BA0-0AA0 unit CA Support brackets 3WL9-0BB50-0AA0 unit CA For mounting fixed-mounted circuit breakers on vertical plane Only for sizes I and II ( set = 2 units) 3WL9-0BB50-0AA0 CubicleBUS modules 3)6) Digital output modules with rotary coding switch, relay outputs 3WL9-0AT26-0AA0 unit CA Digital output modules, configurable, relay outputs 3WL9-0AT20-0AA0 unit CA 0.30 Digital input modules 3WL9-0AT27-0AA0 unit CA Analog output modules 3WL9-0AT23-0AA0 unit CA Zone Selective Interlocking modules 3WL9-0AT2-0AA0 unit CA NSE0_0023a 3WL9-0AT23-0AA0 Parameterization systems 6) NSE0_0024a 3WL9-0AT28-0AA0 BDA Plus 4)5) 3WL9-0AT33-0AA0 unit CA.200 Parameterization, operation, monitoring and diagnostics of 3WL air circuit breakers using the local interface Breaker Data Adapter, connection cable to the 3WL air circuit breaker and to the programming device (e.g. notebook) Can be run with Internet Explorer with JAVA2 VM and higher With Ethernet interface for connection to Ethernet/Intranet/ Internet Connection cables for BDA Plus 3WL9-0BC2-0AA0 unit CA Connection cable for connection of BDA Plus to terminal X8 of the 3WL air circuit breaker Required if neither COM5 nor COM6 nor other external CubicleBUS modules are available Length 2 m powerconfig parameterization software Parameterization, operation, monitoring and diagnostics of 3WL air circuit breakers using powerconfig software, see Chapter "Software", "Configuring, Visualizing and Controlling with SENTRON". powerconfig is available free of charge at ) For 60 ka ground short-circuit current, order 2. 2) Cannot be used for size II with very high breaking capacity C and size II, 4000 A. 3) Each CubicleBUS module is supplied with a 0.2 m factory-fitted cable to connect the modules with each other. A longer factory-fitted cable is required for connection to the circuit breaker. 4) A 24 V DC power supply unit is required. 5) Operation under Windows Vista and Windows 7 possible with restrictions. 6) All communication components, CubicleBUS modules and measurement functions are available for the ETU45B and ETU76B Electronic Trip Units. /66 Siemens LV 0 206/207

67 3WL /Non-Automatic Designation Accessories for communications 3) Preassembled cables for CubicleBUS modules Versions DT Article No. Accessories and spare parts Price SET, M) 0.5 m long, for connection to 3WL with COM5/COM6 3WL9-0BC04-0AA0 unit CA m long, for connection to 3WL with COM5/COM6 3WL9-0BC02-0AA0 unit CA m long, for connection to 3WL with COM5/COM6 3WL9-0BC03-0AA0 unit CA m long, for connection to 3WL without COM5/COM6 3WL9-0BC05-0AA0 unit CA SENTRON manual for communication solutions Detailed description of the communication functions for circuit breakers. Installation, connection, commissioning, data transmission to the PLC. Free download from: lowvoltage/manuals Voltage transformers 3WL9-0BB68-0AA0 unit CA pole, for 3WL circuit breakers with measurement function Plus ) V/00 V, class 0.5 Retrofitting and spare parts 3) PROFIBUS retrofit kits 3WL9-0AT2-0AA0 unit CA Retrofit kit for PROFIBUS communications including COM5, BSS and set of cables for all 3WL air circuit breakers with ETU45B and ETU76B Electronic Trip Units Device COM5 PROFIBUS module 3WL9-0AT5-0AA0 unit CA 0.40 For ETU45B and ETU76B Electronic Trip Units PROFIBUS DP CubicleBus NSE0_0025 3WL9-0AT5-0AA0 COM6 MODBUS modules 3WL9-0AT7-0AA0 unit CA 0.40 For ETU45B and ETU76B Electronic Trip Units MODBUS IEC retrofit kits 3WL9-0AT8-0AA0 unit EA Retrofit kit for MODBUS communications including COM6, BSS and set of cables for all 3WL air circuit breakers with ETU45B and ETU76B Electronic Trip Units Breaker status sensor (BSS) 3WL9-0AT6-0AA0 unit CA 0.20 For ETU45B and ETU76B Electronic Trip Units Measurement function Plus 2) 3WL9-0AT04-0AA0 unit CA For ETUs Release 2 Voltage transformer required ) Is required for operation of the measurement function Plus. 2) A measuring accuracy of 3 % is reached if retrofitted. 3) All communication components, CubicleBUS modules and measurement functions are available for the ETU45B and ETU76B Electronic Trip Units. Siemens LV 0 206/207 /67

68 3WL /Non-Automatic Accessories and spare parts Designation Main conductor connections, fixed-mounted versions (essential accessory) Specified for each connection 3WL9-0AL06-0AA0 NSE0_000 3WL9-0AL56-0AA0 3WL9-0AL4-0AA0 NSE0_00 3WL9-0AL64-0AA0 Front-accessible main connections, single hole at top ) DT Article No. Price SET, M) Rated current I n I Up to 000 A 3WL9-0AL0-0AA0 unit CA A to 600 A 3WL9-0AL02-0AA0 unit CA.600 II 4) Up to 2000 A 3WL9-0AL03-0AA0 unit CA Up to 2500 A 3WL9-0AL04-0AA0 unit CA Up to 3200 A 3WL9-0AL05-0AA0 unit CA III Up to 4000 A 3WL9-0AL06-0AA0 unit CA 6.00 Front-accessible main connections, single hole at bottom ) Rated current I n I Up to 000 A 3WL9-0AL5-0AA0 unit CA A to 600 A 3WL9-0AL52-0AA0 unit CA.300 II 4) Up to 2000 A 3WL9-0AL53-0AA0 unit CA.800 Up to 2500 A 3WL9-0AL54-0AA0 unit CA 3.00 Up to 3200 A 3WL9-0AL55-0AA0 unit CA III Up to 4000 A 3WL9-0AL56-0AA0 unit CA Front-accessible main connections according to DIN 43673, double hole at top Rated current I n I Up to 000 A ) 3WL9-0AL07-0AA0 unit CA A to 2000 A 3WL9-0AL08-0AA0 unit CA II 4) Up to 2000 A 3WL9-0AL-0AA0 unit CA Up to 2500 A 3WL9-0AL2-0AA0 unit CA Up to 3200 A 3WL9-0AL3-0AA0 unit CA III Up to 4000 A 3WL9-0AL4-0AA0 unit CA Front-accessible main connections according to DIN 43673, double hole at bottom Rated current I n I Up to 000 A ) 3WL9-0AL57-0AA0 unit CA A to 2000 A 3WL9-0AL58-0AA0 unit CA.700 II 4) Up to 2000 A 3WL9-0AL6-0AA0 unit CA Up to 2500 A 3WL9-0AL62-0AA0 unit CA Up to 3200 A 3WL9-0AL63-0AA0 unit CA III Up to 4000 A 3WL9-0AL64-0AA0 unit CA Rear vertical main connections Rated current I n I 2) Up to 2000 A 3WL9-0AM0-0AA0 unit CA II 3) Up to 3200 A 3WL9-0AM02-0AA0 unit CA III Up to 6300 A 3WL9-0AM03-0AA0 unit CA NSE0_002 3WL9-0AM03-0AA0 ) Not for 3WL size I with high breaking capacity H. 2) In the case of vertical connection size I with breaking capacity N and S, up to 000 A one 3WL9 0AM0-0AA0 vertical connection is required, up to 2000 A or with breaking capacity H two 3WL9-0AM0-0AA0 vertical connections are required. 3) In the case of vertical connection size II, up to 2500 A one 3WL9 0AM02-0AA0 vertical connection is required, up to 3200 A two 3WL9-0AM02-0AA0 vertical connections are required. 4) Not for circuit breakers with very high breaking capacity C. /68 Siemens LV 0 206/207

69 3WL /Non-Automatic Designation Main conductor connections, withdrawable versions (essential accessory) Specified for each connection NSE0_003 3WL9-0AN06-0AA0 NSE0_004 3WL9-0AN4-0AA0 Front-accessible main connections, ) 2) single hole at top or at bottom DT Article No. Accessories and spare parts Price SET, M) Rated current I n I Up to 000 A 3WL9-0AN0-0AA0 unit CA A to 600 A 3WL9-0AN02-0AA0 unit CA.300 II 3) Up to 2000 A 3WL9-0AN03-0AA0 unit CA.800 Up to 2500 A 3WL9-0AN04-0AA0 unit CA 3.00 Up to 3200 A 3WL9-0AN05-0AA0 unit CA III Up to 4000 A 3WL9-0AN06-0AA0 unit CA Front-accessible main connections according to DIN 43673, double hole at top or at bottom ) Rated current I n I Up to 000 A 2) 3WL9-0AN07-0AA0 unit CA A to 2000 A 3WL9-0AN08-0AA0 unit CA.700 II 3) Up to 2000 A 3WL9-0AN-0AA0 unit CA Up to 2500 A 3WL9-0AN2-0AA0 unit CA Up to 3200 A 3WL9-0AN3-0AA0 unit CA III Up to 4000 A 3WL9-0AN4-0AA0 unit CA Supports for front and DIN connecting bars Number of poles 3-pole for 3 bars I 3WL9-0AN4-0AA0 unit CA II 3WL9-0AN42-0AA0 unit CA.350 III 3WL9-0AN43-0AA0 unit CA pole for 4 bars I 3WL9-0AN44-0AA0 unit CA.200 II 3WL9-0AN45-0AA0 unit CA III 3WL9-0AN46-0AA0 unit CA NSE0_007 3WL9-0AN4-0AA0 NSE0_005 3WL9-0AN23-0AA0 NSE0_006 3WL9-0AN24-0AA0 Rear vertical main connections Rated current I n I Up to 000 A 2) 3WL9-0AN5-0AA0 unit CA A to 2000 A 3WL9-0AN6-0AA0 unit CA II Up to 2000 A 3) 3WL9-0AN7-0AA0 unit CA.50 Up to 2500 A 3) 3WL9-0AN8-0AA0 unit CA.490 Up to 3200 A 3) 3WL9-0AN2-0AA0 unit CA A 4) 3WL9-0AN38-0AA0 unit CA III Up to 5000 A 3WL9-0AN22-0AA0 unit CA Rear horizontal main connections Up to 6300 A, 3 busbar connection pieces for 3-pole circuit breakers Up to 6300 A, at top, 4 busbar connection pieces for 4-pole circuit breakers Up to 6300 A, at bottom, 4 busbar connection pieces for 4-pole circuit breakers ) When using front-accessible mains connections (withdrawable circuit breakers) supports are required. 2) Not for 3WL size I with high breaking capacity H. 3WL9-0AN23-0AA0 unit CA WL9-0AN20-0AA0 unit CA WL9-0AN0-0AA0 unit CA Rated current I n I Up to 000 A 2) 3WL9-0AN32-0AA0 unit CA A to 2000 A 3WL9-0AN33-0AA0 unit CA II Up to 2000 A 3) 3WL9-0AN34-0AA0 unit CA.020 Up to 2500 A 3) 3WL9-0AN35-0AA0 unit CA.240 Up to 3200 A 3) 3WL9-0AN36-0AA0 unit CA A 4) 3WL9-0AN47-0AA0 unit CA 2.50 III Up to 5000 A 3WL9-0AN37-0AA0 unit CA Connecting flange Rated current I n I Up to 000 A 2) 3WL9-0AN24-0AA0 unit CA A to 2000 A 3WL9-0AN25-0AA0 unit CA II 3) Up to 2000 A 3WL9-0AN26-0AA0 unit CA Up to 2500 A 3WL9-0AN27-0AA0 unit CA.020 Up to 3200 A 3WL9-0AN28-0AA0 unit CA.30 III Up to 4000 A 3WL9-0AN3-0AA0 unit CA ) Not for circuit breakers with very high breaking capacity C. 4) Only for circuit breakers with very high breaking capacity C. Siemens LV 0 206/207 /69

70 3WL /Non-Automatic Accessories and spare parts Conversion sets Main contact elements Designation Conversion set for converting fixed-mounted circuit breakers into withdrawable circuit breakers ) Guide frames and sliding contact modules must be ordered separately. Number of poles DT Article No. Price SET, M) 3-pole I 3WL9-0BC-0AA0 unit CA 5.00 II 3WL9-0BC2-0AA0 unit CA III 3WL9-0BC3-0AA0 unit CA pole I 3WL9-0BC4-0AA0 unit CA Main contact elements 2)4) II 3WL9-0BC5-0AA0 unit CA III 3WL9-0BC6-0AA0 unit CA I n max NSE0_002 I Up to 600 A 3WL9-0AM90 unit CA LY 3) II Up to 2500 A 3WL9-0AM9 unit CA LY 3) II Up to 4000 A 3WL9-0AM92 unit CA LY 3) III Up to 6300 A 3WL9-0AM93 unit CA LY 3) Notes The circuit breaker ID No. must be specified when ordering Specified for each connection (depending on the number of poles on the circuit breaker, order 3 or 4 units) Article No. is automatically adapted to the circuit breaker ID No. ) Conversion from fixed-mounted to withdrawable is not possible for 3WL circuit breakers with very high breaking capacity C. 2) Not for circuit breakers with very high breaking capacity C. 3) Please specify the circuit breaker ID No. in plain text when ordering. 4) Replacement of the main contact elements for 3WL circuit breakers with very high breaking capacity C is only possible at the factory. /70 Siemens LV 0 206/207

71 3WL /Non-Automatic Version DT Article No. Withdrawable short-circuiting, grounding and bridging units Withdrawable short-circuiting, grounding and bridging units Top and bottom system components are short-circuited and grounded. Number of poles Rated current I n Accessories and spare parts Price SET, M) 3-pole Up to 600 A I 3WL9-0BD0-0AA0 unit CA Up to 3200 A II 3WL9-0BD03-0AA0 unit CA Up to 6300 A III 3WL9-0BD05-0AA0 unit CA pole Up to 600 A I 3WL9-0BD02-0AA0 unit CA Up to 3200 A II 3WL9-0BD04-0AA0 unit CA Up to 6300 A III 3WL9-0BD06-0AA0 unit CA Conversion for the following applications is possible NSE0_03 L L2 L3 NSE0_08 NSE0_02 L L2 L3 NSE0_06 N L L2 L3 NSE0_09 N L L2 L3 NSE0_07 Top and bottom system components are short-circuited and grounded (as-supplied state) Top system component is short-circuited and grounded, infeed from bottom NSE0_022a L L2 L3 NSE0_020 NSE0_05 NSE0_04 NSE0_023a N L L2 L3 NSE0_02 Withdrawable bridging unit, infeed and outgoing sides are permanently connected to each other Bottom system component is short-circuited and grounded, infeed from top Siemens LV 0 206/207 /7

72 3WL /Non-Automatic Options Accessories and spare parts Structure of the Article No. 3WL ÔÔÒ ÖéâÕÓ ÓáÜÔ An important prerequisite for electronic order processing is that article numbers must be Example structured according to 5th position: II Ô standardized criteria. 6th and 7th positions: 8th position: 9th position: 0th position: Accessories: With first order (components are already mounted) Accessories: For retrofitting (components for subsequent fitting) Documentation Max. rated circuit breaker current I n max Breaking capacity class I n max = 2000 A High breaking capacity "H": 00 ka Electronic Trip Units ETU76B with graphics display... Electronic Trip Unit supplement ÔÒ... with ground-fault protection â th position: Number of poles Three-pole Õ 2th position: Installation type Fixed-mounted, main connections on rear, vertical 3th position: 4th position: Operating mechanisms Manual operating mechanism with mechanical closing st auxiliary release Shunt release 50/60 Hz 0 V AC 5th position: 2nd auxiliary release Without 2nd auxiliary release Ü 6th position: Auxiliary switches 2 NO contacts + 2 NC contacts Ô Example "-Z" with order code Example 3WL9 ÓÓÓ ÒÁÜÔÓ ÒÜÜÒ Interlocking set for mechanical ON/OFF without lock Operating manual Complete set PROFIBUS manual Communication MODBUS manual Communication Ö é Ó Ó á They are used as an unambiguous means of communication for various purposes: Offer processing Selection and configuration Order processing Orders Order confirmation Processing of products for storage Order processing in supply locations Supply and dispatch Reporting and planning Service and warranty The standardized structure ensures that only one Article No. has to be administered for one device. This saves time and effort during planning, configuring, ordering and in stock keeping, and consequently above all it saves costs. The example opposite explains the various positions within an Article No. 3WL ÔÓØ ÖåâÕÓ ÓáÜÕ õ áòô Additional accessory components can be ordered ready-mounted. Communications interface "Standard" + Breaker Status Sensor (BSS) + communication module COM5 for connection to PROFIBUS DP õ áòô These supplements are identified by " Z". Even with additional components, one Article No. is sufficient. Additional accessories which are not intended to be ready-mounted in the factory, such as spare parts for storage, can also be ordered separately from the circuit breaker. Accessories for retrofitting are identified by the Article No. stem 3WL9. German/English Article No. 3ZX8 2-0WL00-0AN2 Delivery time class C French/Italian Article No. 3ZX8 2-0WL00-0AJ2 On request Spanish/Portuguese Article No. 3ZX8 2-0WL00-0AL2 On request German Article No. A5E05347 English Article No. A5E05353 German Article No. 3ZX02-0WL0-AB English Article No. 3ZX02-0WL0-AC Free download of documentation from lowvoltage/manuals More information Up-to-date information on the Internet at: sentron /72 Siemens LV 0 206/207

73 3WL Non-Automatic up to 4000 A (DC), IEC Technical specifications I II Type 3WL20 3WL20 3WL220 3WL240 Rated current I n at 40 C Main conductor A Rated operational voltage U e (000 V version, order code "A05") V DC / / /000 Rated insulation voltage U i V DC Rated impulse withstand voltage U imp Main conducting paths Auxiliary circuits Control circuits kv 2 kv 4 kv 2.5 Isolating function acc. to EN Yes Yes Yes Yes Utilization category B Permissible ambient temperature Operation Storage Permissible load At rear horizontal main connections (Cu painted black) Up to 40 C Up to 55 C Up to 60 C Up to 70 C C 25/+70 C 40/+70 A A A A /+70 40/ /+70 40/+70 Power loss at I n for symmetrical loads Withdrawable circuit breakers W Switching times Make time Opening time Electrical make time (through activation solenoid) ) Electrical opening time (through shunt release) ms ms ms ms Electrical opening time (instantaneous undervoltage release) ms 73 Endurance 3) Mechanical (without maintenance) Operating cycles Mechanical (with maintenance) 2) Operating cycles Electrical (without maintenance) Operating cycles V version Operating cycles 000 Electrical (with maintenance) 2) Operating cycles 2000 Switching frequency 600 V version 000 V version Mounting position /h /h and/ or /+70 40/ Dhmax. = mm General data Degree of protection Auxiliary conductors (Cu) Max. number Auxiliary conductors cross-section (solid/stranded) s 3-pole 4-pole Standard connection = strain-relief clamp Without end sleeve With end sleeve acc. to DIN Part 2 With twin end sleeve Optional connection = tension spring Without end sleeve With end sleeve acc. to DIN Part 2 Fixed-mounted circuit breakers Withdrawable circuit breakers Guide frames Fixed-mounted circuit breakers Withdrawable circuit breakers Guide frames ) Make-time through activation solenoid for synchronization purposes (short-time excited) 50 ms. 2) Maintenance means: replace main contact elements and arc chutes (see Operating Manual). 3) Further technical specifications on request IP20 without cabinet door, IP4 with door sealing frame, IP55 with cover mm 2 (AWG 20) mm 2 (AWG 6); 2.5 mm 2 (AWG 4) 0.5 mm 2 (AWG 20)....5 mm 2 (AWG 6) mm 2 (AWG 20) mm 2 (AWG 6) mm 2 (AWG 20) mm 2 (AWG 4) mm 2 (AWG 20) mm 2 (AWG 6) NSE0_0006a NSE0_00062a NSE0_00927 Siemens LV 0 206/207 /73

74 3WL Non-Automatic up to 4000 A (DC), IEC Siemens AG 206 General data Breaking capacity I II DC Type 3WL 3WL2 Breaking capacity DC DC Short-circuit breaking capacity Up to 220 V DC Up to 300 V DC Up to 600 V DC I cc I cc I cc ka ka ka Up to 000 V DC I cc ka Rated short-time withstand current I cw 0.5 s s 2 s 3 s ka ka ka ka DC 35 ) /30 2) /25 3) /20 4) N S H C DC Note: Circuit breakers with ECO breaking capacity N Circuit breakers with standard breaking capacity S Circuit breakers with high breaking capacity H Circuit breakers with very high breaking capacity C Non-automatic air circuit breakers with DC breaking capacity These breaking capacities are indicated in the corresponding tables by the symbols shown on orange bacrounds. For further technical specifications, see the configuration manual "". Free download from: lowvoltage/manuals Abbreviations* (functions) English long text Explanation L Long Time Delay Overload protection S Short Time Delay Short-circuit protection (short-time delayed) I Instantaneous Short-circuit protection (instantaneous) N Neutral Protection Neutral conductor protection G Ground Fault Ground-fault protection * Designations according to IEC , Appendix K. ) At U e = 220 V DC. 2) At U e = 300 V DC. 3) At U e = 600 V DC. 4) At U e = 000 V DC. /74 Siemens LV 0 206/207

75 3WL Non-Automatic up to 4000 A (DC), IEC Application examples General data Rated operational voltage Up to 300 V + 0 % Required seriesconnected contact gaps at rated voltage For 3-pole non-automatic air circuit breakers (operational currents up to 4000 A/conducting path) For 4-pole non-automatic air circuit breakers (operational currents up to 4000 A/conducting path) Over 300 V + 0 % Up to 600 V + 0 % NSS0_ pole, 2 parallel conducting paths, only with grounded system 2-pole -pole, 3 parallel conducting paths, only with grounded system 2-pole 2 parallel conducting paths Over 600 V + 0 % Up to 000 V + 0 % (version for 000 V required, order with "-Z" and order code A05) 2-pole, only with grounded system -pole, only with grounded system -pole, 2 parallel conducting paths, only with grounded system 2-pole, only with grounded system 2-pole NSS0_ pole, only with grounded system Connection to the circuit breakers is independent of the direction and polarity; the circuit diagrams can be converted analogously. If the parallel or series connections are established directly to the connecting bars, for thermal reasons the circuit breakers may only be subjected continuously to 80 % of the permissible operational current. If the parallel or series connection is made at a distance of m from the connecting bars, the circuit breaker can be used at full operational current load. ] grounded system load Siemens LV 0 206/207 /75

76 3WL Non-Automatic up to 4000 A (DC), IEC Siemens AG and 4-pole, fixed-mounted versions Selection and ordering data For general data, see page /8. Max. rated circuit breaker current DT 3-pole non-automatic air circuit I n max breakers Article No.: Price SET, M) A Horizontal main circuit connection II 000 3WL20-8@@32-@@@@ unit CA WL220-8@@32-@@@@ unit CA ) 3WL240-8@@32-@@@@ unit CA Vertical main circuit connection II 000 3WL20-8@@3-@@@@ unit CA WL220-8@@3-@@@@ unit CA ) 3WL240-8@@3-@@@@ unit CA Front main circuit connection, single hole II 000 3WL20-8@@33-@@@@ unit CA WL220-8@@33-@@@@ unit CA Front main circuit connection, double hole II 000 3WL20-8@@34-@@@@ unit CA WL220-8@@34-@@@@ unit CA Options Add. price Non-automatic air circuit Without Electronic Trip Units AA None breakers 2) Operating mechanisms Manual operating mechanism with mechanical closing For further Article No. supplements, see page /44 AA2 None Max. rated circuit breaker current DT 4-pole non-automatic air circuit I n max breakers Article No.: Price SET, M) A Horizontal main circuit connection I 3) WL20-8@@42-@@@@ unit CA II 000 3WL20-8@@42-@@@@ unit CA WL220-8@@42-@@@@ unit CA ) 3WL240-8@@42-@@@@ unit CA Vertical main circuit connection I 3) WL20-8@@4-@@@@ unit CA II 000 3WL20-8@@4-@@@@ unit CA WL220-8@@4-@@@@ unit CA ) 3WL240-8@@4-@@@@ unit CA Front main circuit connection, single hole II 000 3WL20-8@@43-@@@@ unit CA WL220-8@@43-@@@@ unit CA Front main circuit connection, double hole II 000 3WL20-8@@44-@@@@ unit CA WL220-8@@44-@@@@ unit CA Options Add. price Non-automatic air circuit Without Electronic Trip Units AA None breakers 2) Operating mechanisms Manual operating mechanism with mechanical closing For further Article No. supplements see page /44 DC DC AA2 None Add "-Z" to the complete Article No. and indicate the appropriate order code(s). 3WL Z @ 3-pole 4-pole Condition Rated current I n Rated voltage 000 V II Up to 2000 A A 0 5 DC Up to 4000 A A 0 5 Note For voltages over 600 V use the version for 000 V DC rated voltage for size II: Order with "-Z" and order code "A05". All other accessory parts must be ordered by specifying "-Z" and the corresponding order code, see "3WL /Non-Automatic ", "Options", from page /45. An external overload and short-circuit protection device is available from the company "mat" for the 3WL non-automatic air circuit breakers. Available only directly from the company "mat" Maschinen- und Anlagentechnik (for the address, see page /78). ) Provisions to dissipate heat must be made on the line side. 2) For permissible rated short-time current I cw and short-circuit breaking capacity I cc for non-automatic air circuit breakers, see page /3. /76 Siemens LV 0 206/207 3) 3WL20-8 DC non-automatic air circuit breakers are designed for a rated voltage of 000 V DC. Additional price

77 3WL Non-Automatic up to 4000 A (DC), IEC Selection and ordering data 3- and 4-pole, withdrawable versions Without guide frames (for guide frames, see page /79) Max. rated circuit breaker current I n max A DT 3-pole non-automatic air circuit breakers Article No. Price SET, M) II 000 3WL20-8@@35-@@@@ unit CA WL220-8@@35-@@@@ unit CA ) 3WL240-8@@35-@@@@ unit CA With guide frames, horizontal main circuit connection II 000 3WL20-8@@36-@@@@ unit CA WL220-8@@36-@@@@ unit CA ) 3WL240-8@@36-@@@@ unit CA With guide frames, vertical main circuit connection II 000 3WL20-8@@37-@@@@ unit CA WL220-8@@37-@@@@ unit CA ) 3WL240-8@@37-@@@@ unit CA With guide frames, connecting flanges II 000 3WL20-8@@38-@@@@ unit CA WL220-8@@38-@@@@ unit CA ) 3WL240-8@@38-@@@@ unit CA DC Options Non-automatic air circuit breakers 2) Operating mechanisms Without Electronic Trip Units Manual operating mechanism with mechanical closing For further Article No. supplements, see page /44 Add. price AA None AA2 None Add "-Z" to the complete Article No. and indicate the appropriate order @ Additional price 3-pole Condition Rated current I n Rated voltage 000 V DC II 4) Up to 2000 A A 0 5 Tinned version of the customer's connections on the guide frame 3) Only for circuit breakers in withdrawable version with horizontal connection or flange connection. The normal delivery time increases to 5 work days. Note Additional price ) Provisions to dissipate heat must be made on the line side. 2) For permissible rated short-time current I cw and short-circuit breaking capacity I cc for non-automatic air circuit breakers, see page /3. 3) The permissible temperature-rise limits according to IEC are 5 K lower for a tin surface than for a silver surface. 4) If ordering withdrawable circuit breaker and guide frame separately, specify order code "A05" for withdrawable circuit breaker and guide frame. Up to 4000 A A 0 5 II A 0 8 For voltages over 600 V use the version for 000 V DC rated voltage: Order with "-Z" and order code "A05". All other accessory parts must be ordered by specifying "-Z" and the corresponding order code, see "3WL /Non-Automatic ", "Options", from page /45. An external overload and short-circuit protection device is available from the company "mat" for the 3WL non-automatic air circuit breakers. Available only directly from the company "mat" Maschinen- und Anlagentechnik (for the address, see page /78). Siemens LV 0 206/207 /77

78 3WL Non-Automatic up to 4000 A (DC), IEC Siemens AG and 4-pole, withdrawable versions Selection and ordering data Without guide frames (for guide frames, see page /79) Max. rated circuit breaker current I n max A DT 4-pole non-automatic air circuit breakers Article No. Price SET, M) II 000 3WL20-8@@45-@@@@ unit CA WL220-8@@45-@@@@ unit CA ) 3WL240-8@@45-@@@@ unit CA With guide frames, horizontal main circuit connection II 000 3WL20-8@@46-@@@@ unit CA WL220-8@@46-@@@@ unit CA ) 3WL240-8@@46-@@@@ unit CA With guide frames, vertical main circuit connection II 000 3WL20-8@@47-@@@@ unit CA WL220-8@@47-@@@@ unit CA ) 3WL240-8@@47-@@@@ unit CA With guide frames, connecting flanges II 000 3WL20-8@@48-@@@@ unit CA WL220-8@@48-@@@@ unit CA ) 3WL240-8@@48-@@@@ unit CA DC Options Non-automatic air circuit breakers 2) Operating mechanisms Without Electronic Trip Units Manual operating mechanism with mechanical closing For further Article No. supplements, see page /44 Add. price AA None AA2 None Add "-Z" to the complete Article No. and indicate the appropriate order @ Additional price 4-pole Condition Rated current I n Rated voltage 000 V DC II 4) Up to 2000 A A 0 5 Tinned version of the customer's connections on the guide frame 3) Only for circuit breakers in withdrawable version with horizontal connection or flange connection. The normal delivery time increases to 5 work days. Note Additional price ) Provisions to dissipate heat must be made on the line side. 2) For permissible rated short-time current I cw and short-circuit breaking capacity I cc for non-automatic air circuit breakers, see page /3. 3) The permissible temperature-rise limits according to IEC are 5 K lower for a tin surface than for a silver surface. 4) If ordering withdrawable circuit breaker and guide frame separately, specify order code "A05" for withdrawable circuit breaker and guide frame. Up to 4000 A A 0 5 II A 0 8 For voltages over 600 V use the version for 000 V DC rated voltage: Order with "-Z" and order code "A05". All other accessory parts must be ordered by specifying "-Z" and the corresponding order code, see "3WL /Non-Automatic ", "Options", from page /45. An external overload and short-circuit protection device is available from the company "mat" for the 3WL non-automatic air circuit breakers. Available only directly from the company "mat" Maschinen- und Anlagentechnik 5). 5) mat Maschinen- und Anlagentechnik Dr. Becker GmbH Rudolf-Diesel-Strasse 22 D-2294 Bargteheide Tel.: +49 (45 32) Fax: +49 (45 32) info@m-a-t.de Internet: /78 Siemens LV 0 206/207

79 Selection and ordering data Guide frames for DC non-automatic air circuit breakers Siemens AG 206 3WL Non-Automatic up to 4000 A (DC), IEC Accessories and spare parts A Front main circuit connection, single hole Max. rated circuit breaker current DT Guide frames for 3-pole I n max non-automatic air circuit breakers Article No. Price SET, M) II WL922-3DA@@-@@A unit CA Front main circuit connection, double hole II WL922-3DB@@-@@A unit CA Horizontal main circuit connection II WL922-3DC@@-@@A unit CA WL922-6DC@@-@@A unit CA Vertical main circuit connection II WL922-3DD@@-@@A unit CA WL922-6DD@@-@@A unit CA Main circuit connection connecting flanges II WL922-3DE@@-@@A unit CA WL922-6DE@@-@@A unit CA Options Number of auxiliary supply connectors Note Add. price 3-pole None 0 None connector For table for required number of auxiliary supply connectors, see page /5. Type of auxiliary circuit connections 2 connectors 2 3 connectors 3 4 connectors 4 None 0 None With screw connection (SI- GUT, standard) With screwless connection method (tension spring) 2 Position signaling switches None 0 None Option : Connected position CO, test position CO, disconnected position CO Option 2: Connected position 3 CO, test position 2 CO, disconnected position CO 2 Shutters None A None With shutter, 2-part, lockable B Add "-Z" to the complete Article No. and indicate the appropriate order @ Additional price Rated voltage 000 V DC II A 0 5 Tinned version of the customer's connections on the guide frame ) Only for guide frames with horizontal connection or flange connection II A 0 8 Notes For guide frames for 4-pole DC non-automatic air circuit breakers, see the following page. All other accessory parts must be ordered by specifying " Z" and the corresponding order code, see "3WL /Non-Automatic ", "Options", page /45 onwards. Additional price ) The permissible temperature-rise limits according to IEC are 5 K lower for a tin surface than for a silver surface. Siemens LV 0 206/207 /79

80 3WL Non-Automatic up to 4000 A (DC), IEC Siemens AG 206 Accessories and spare parts Max. rated circuit breaker current DT Guide frames for 4-pole I n max non-automatic air circuit breakers Article No. Price SET, M) A Front main circuit connection, single hole II WL922-3EA@@-@@A unit CA Front main circuit connection, double hole II WL922-3EB@@-@@A unit CA Horizontal main circuit connection II WL922-3EC@@-@@A unit CA II WL922-6EC@@-@@A unit CA Vertical main circuit connection II WL922-3ED@@-@@A unit CA II WL922-6ED@@-@@A unit CA Main circuit connection connecting flanges II WL922-3EE@@-@@A unit CA II WL922-6EE@@-@@A unit CA Options Number of auxiliary supply connectors Note For table for required number of auxiliary supply connectors, see page /5. Type of auxiliary circuit connections Add. price 4-pole None 0 None connector 2 connectors 2 3 connectors 3 4 connectors 4 None 0 None With screw connection (SI- GUT, standard) With screwless connection method (tension spring) 2 Position signaling switches None 0 None Option : Connected position CO, test position CO, disconnected position CO Option 2: Connected position 3 CO, test position 2 CO, disconnected position CO 2 Shutters None A None With shutter, 2-part, lockable B Add "-Z" to the complete Article No. and indicate the appropriate order @ Additional price Rated voltage 000 V DC II A 0 5 Tinned version of the customer's connections on the guide frame ) Only for guide frames with horizontal connection or flange connection II A 0 8 Notes For guide frames for 3-pole DC non-automatic air circuit breakers see previous page. All other accessory parts must be ordered by specifying " Z" and the corresponding order code, see "3WL /Non-Automatic ", "Options", page /45 onwards. ) The permissible temperature-rise limits according to IEC are 5 K lower for a tin surface than for a silver surface. /80 Siemens LV 0 206/207

81 Overview 3WL5 /Non-Automatic Introduction 3WL5: Superior individual products integrated into uniform power distribution systems up to and including industry-specific industrial and infrastructure solutions NSE0_0902 $ Guide frame, see page /02 % Main circuit connection front, flange, horizontal, vertical see page /98 and page /4 & Position signaling switch, see page /97 and page /08 ) Shutters, see page /97 * COM5 PROFIBUS module or COM6 MODBUS module, see page /3 + External CubicleBUS modules, see page /2, Closing coil, auxiliary release, see page /95 - Auxiliary conductor plug-in system, see page /98. Auxiliary switch block, see page /95 / Door sealing frame, see page /96 0 Interlocking set for mechanical ON/OFF, see page /05 Transparent panel, function insert, see page /05 2 EMERGENCY-STOP pushbutton, key operated, see page /08 3 Motorized operating mechanism, see page /97 4 Operating cycles counter, see page /96 5 Breaker Status Sensor (BSS), see page /98 6 Protective devices with device holder, Electronic Trip Unit (ETU) see page /04 7 Remote reset solenoid, see page /96 8 Breaker Data Adapter (BDA Plus), see page /2 9 Four-line display, see page /04 : Ground-fault protection module, see page /04 ; Rating plug, see page /96 < Metering function module, see page /98 = Air circuit breaker, see page /89 to page /94 Siemens LV 0 206/207 /8

82 3WL5 /Non-Automatic Introduction Communication-capable circuit breakers (with ETU45B Electronic Trip Unit) 20 Ethernet 8 9 PROFIBUS PROFINET VA-line 3VA-line NSE0_005n 8 CubicleBUS VA molded case circuit breakers 3VL molded case circuit breakers Electronic trip unit ETU / LCD ETU COM800 breaker data server COM00 breaker data server COM20 Release 2 PROFIBUS module including Zone Selective Interlocking BDA Plus with Ethernet interface 3WL air circuit breaker COM5 PROFIBUS module Breaker status sensor (BSS) Electronic trip unit (ETU) Measurement function Plus Zone Selective Interlocking module Digital output module with relay contacts Digital output module with relay contacts, configurable Analog output modules Digital input modules Configuration software powerconfig V2.3 and higher PLC, e.g. SIMATIC S7 E.g. SIMATIC powerrate 7KM PAC measuring devices Characteristics Coordinated communication concept using the PROFIBUS DP or MODBUS, ranging from 6 A to 5000 A with 3VL molded case circuit breakers and 3WL5 air circuit breakers The high level of modularity of circuit breakers and accessories allows easy retrofitting of all communication components Significant additional benefits for the switchgear due to the possibility of linking up external input and output modules to the circuit breaker-internal CubicleBUS of the 3WL5 air circuit breaker Innovative software products for parameterization, operation, monitoring, and diagnostics of circuit breakers, both locally or via PROFIBUS DP, MODBUS or Ethernet/Intranet/Internet Complete integration of the circuit breakers into the Totally Integrated Power and Totally Integrated Automation solutions Communication: For air circuit breakers with optional communication function (ETU45B Electronic Trip Units) see page /04. For accessories, see page /0 to page /6. For more information, See chapter "Measuring Devices and Power Monitoring". /82 Siemens LV 0 206/207

Siemens AG Air Circuit Breakers. Totally Integrated Power SENTRON. Configuration. Edition 10/2014. Manual. siemens.

Siemens AG Air Circuit Breakers. Totally Integrated Power SENTRON. Configuration. Edition 10/2014. Manual. siemens. Siemens AG Air Circuit Breakers Totally Integrated Power SENTRON Configuration Manual Edition / siemens.com/lowvoltage Siemens AG Siemens AG WL Air Circuit Breakers Introduction WL air circuit breakers/

More information

SENTRON Switching and Protection Devices Air Circuit Breakers

SENTRON Switching and Protection Devices Air Circuit Breakers SENTRON Switching and Protection Devices ir Circuit Breakers /2 Introduction 3WL ir Circuit Breakers 3WL ir Circuit Breakers/ Non-utomatic ir Circuit Breakers up to 6300 (C) /6 - Design /2 - Function /9

More information

SENTRON 3VL Molded Case Circuit Breakers

SENTRON 3VL Molded Case Circuit Breakers Siemens AG SENTRON VL Molded Case Circuit Breakers Switching, Protection, Measuring and Monitoring Devices For the operating range from A to 00 A, the molded case circuit breaker ensures the optimum overload

More information

New Functions and Integrated Communication Capability. The new SENTRON 3VL ETUs SENTRON 3VL. Answers for industry.

New Functions and Integrated Communication Capability. The new SENTRON 3VL ETUs SENTRON 3VL. Answers for industry. New Functions and Integrated Communication Capability The new SENTRON 3VL ETUs SENTRON 3VL Answers for industry. For 3VL2 and 3VL3, the tripping solenoid is integrated in the ETU Undervoltage release 3

More information

Switch Disconnectors, Main and EMERGENCY-STOP Switches

Switch Disconnectors, Main and EMERGENCY-STOP Switches General data Overview Siemens G 2010 1 2 3 NSE0_01931b 4 5 6 7 1 uxiliary switch (3SB for 3K; 3KX for 3KE) 2 IP20 terminal cover (Operator side) 3 3K switch disconnector 4 rcing contacts (only for 3KE)

More information

Protection Equipment

Protection Equipment Protection Equipment Price groups 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J, 143, 401 /2 Introduction Motor starter protectors/ circuit breakers SIRIUS 3RV2 motor starter protectors up to 40 A / General data

More information

3VA molded case circuit breaker up to 1600A. Frei verwendbar Siemens AG 2018

3VA molded case circuit breaker up to 1600A. Frei verwendbar Siemens AG 2018 3VA molded case circuit breaker up to 1600A Unrestricted Siemens AG 2018 siemens.com/3va 3VA molded case circuit breaker New 3VA13/14 with TMTU (Thermal Magnetic Trip Unit) New 3VA27 with ETU (ElectronicTrip

More information

The Intelligent Simplicity. Sentron 3WL Air Circuit Breaker. Answers for industry.

The Intelligent Simplicity. Sentron 3WL Air Circuit Breaker. Answers for industry. The Intelligent Simplicity Sentron 3WL Air Circuit Breaker Answers for industry. SENTRON - Intelligent Simplicity In essence, modularity means: User-friendly ease of planning, multiple use of standard

More information

Sentron 3VT circuit breakers Simply Smart: First choice for power distribution

Sentron 3VT circuit breakers Simply Smart: First choice for power distribution s Sentron 3VT circuit breakers Simply Smart: First choice for power distribution www.siemens.com/industry Sentron 3VT Molded Case Circuit-Breakers - 10-1600Amperes With the standard line of 3VT molded-case

More information

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog Issued February 2011 DATA SHEET 5SX2 MCB Based on Siemens Industrial Control Catalog General Data Trip characteristics Tripping characteristics acc. to EN 60 898 Tripping characteristic A, -5 Type A characteristic

More information

ACCESSORIES FOR MO OVERVIEW

ACCESSORIES FOR MO OVERVIEW OVERVIEW W OVERVIEW W SCHRACK-INFO Calculation of the required number of auxiliary supply connectors Draw-out version: The auxiliary contacts automatically contact when the circuit-breaker is inserted

More information

Siemens AG KD Switch Disconnectors SENTRON. Edition December Answers for infrastructure and cities.

Siemens AG KD Switch Disconnectors SENTRON. Edition December Answers for infrastructure and cities. KD Switch Disconnectors SENTRON Edition December 01 Answers for infrastructure and cities. Related catalogs Low-Voltage Power Distribution and LV 10 Electrical Installation Technology SENTRON SIVACON ALPHA

More information

Siemens AG 2017 SENTRON. 3LD Main Control and EMERGENCY-STOP Switches. Catalog Extract LV 10. Edition 10/2017. siemens.com/switching-devices

Siemens AG 2017 SENTRON. 3LD Main Control and EMERGENCY-STOP Switches. Catalog Extract LV 10. Edition 10/2017. siemens.com/switching-devices Siemens AG 201 SENTRON 3LD Main Control and EMERGENCY-STOP Switches Catalog Extract LV 10 Edition 10/201 siemens.com/switching-devices Siemens AG 201 Related catalogs Low-Voltage Power Distribution and

More information

Power Management System. Multifunction Measuring Instruments

Power Management System. Multifunction Measuring Instruments Power Management System Multifunction Measuring Instruments Power Management System /2 - System overview /2 - More information PAC3200 Multifunction Measuring Instruments /3 - Overview /4 - Benefits /5

More information

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD United States 24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Approvals: IEC 60947-2 Rated

More information

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

DANGER indicates that death or severe personal injury will result if proper precautions are not taken. 3WL/3VL circuit breakers with communication capability - SENTRON Protection devices 3WL/3VL circuit breakers with communication capability - PROFIBUS System Manual PROFIBUS Introduction and overview 1

More information

SENTRON. Modular, Compact, Communication-Capable. Answers for industry. Switching, Protection and Measuring Devices for Low-Voltage Power Distribution

SENTRON. Modular, Compact, Communication-Capable. Answers for industry. Switching, Protection and Measuring Devices for Low-Voltage Power Distribution Modular, Compact, Communication-Capable Switching, Protection and Measuring Devices for Low-Voltage Power Distribution SENTRON Answers for industry. s as in superior with the comprehensive low-voltage

More information

Siemens AG RA6 Fuseless Compact Starters. Catalog News LV 1 N April 2008 SIRIUS.

Siemens AG RA6 Fuseless Compact Starters. Catalog News LV 1 N April 2008 SIRIUS. 3RA Fuseless Compact Starters Catalog News LV 1 N April 2008 SIRIUS www.siemens.com/lowvoltage 3RA Fuseless Compact Starters General data Overview 3RA fuseless compact starters and infeed system for 3RA

More information

The Intelligent simplicity. sentron WL

The Intelligent simplicity. sentron WL Datasheet The Intelligent simplicity sentron WL s Unlimited Possibilities Tangram Tangram is an ancient Chinese game based on seven basic shapes. Tangram, an ancient game: The shapes are always the samethe

More information

Power Management System. Measuring Devices for Power Distribution

Power Management System. Measuring Devices for Power Distribution Power Management System Measuring Devices for Power Distribution Power Management System System overview /2 - Overview /2 - More information SENTRON Power Monitoring Devices General data /3 - Overview

More information

3VA Molded Case Circuit Breakers

3VA Molded Case Circuit Breakers 3VA Molded Case Circuit Breakers Communication Manual Edition 12/2015 www.siemens.com/3va 3VA molded case circuit breaker communication SENTRON Protection devices 3VA molded case circuit breaker communication

More information

MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD

MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD United States MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD Product Information Features and Specifications For Use With: OEM Panels Approvals: UL

More information

3VA molded case circuit breaker. communication SENTRON. Protection devices 3VA molded case circuit breaker communication.

3VA molded case circuit breaker. communication SENTRON. Protection devices 3VA molded case circuit breaker communication. 3VA molded case circuit breaker communication SENTRON Protection devices 3VA molded case circuit breaker communication System Manual Introduction 1 System description 2 Functions 3 Application examples

More information

Description. Installation. Power supply

Description. Installation. Power supply Air circuit breakers Special versions Series MEGT07 0V/500V/DC 50 up to 5000 A The air circuit breakers MEGT07 are suitable for use as disconnecting switch in DC distributions up to a rated voltage of

More information

Siemens AG SENTRON 3NJ4, 3NJ5 In-Line Fuse Switch Disconnectors up to 2000 A

Siemens AG SENTRON 3NJ4, 3NJ5 In-Line Fuse Switch Disconnectors up to 2000 A Switch Disconnectors Introduction Overview All key product features at a glance Compliant with IEC/EN 60439-1, IEC/EN 6094-3 Voltage levels up to 690 V AC Rated operational current from 160 A to 2000 A

More information

FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview

FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview Supplementary Protectors / Miniature Circuit Breakers Page System overview 10/003 10/001 Supplementary protectors

More information

5/2 Product overview. 5/3 Distribution board components. 5/9 Built-in components. 5/17 Mounting components 5. Siemens ET B1 10/2009

5/2 Product overview. 5/3 Distribution board components. 5/9 Built-in components. 5/17 Mounting components 5. Siemens ET B1 10/2009 Siemens AG 9 BETA Protecting SR Busbar Systems /2 Product overview /3 Distribution board components /9 Built-in components /17 Mounting components Siemens ET B1 10/9 BETA Protecting SR Busbar Systems Siemens

More information

Switches 6/1. 6/4 Introduction. 6/5 5TE8 control switches. 6/7 5TE4 8 pushbuttons. 6/9 5TE8 On/Off switches. 6/11 5TE1 switch disconnectors

Switches 6/1. 6/4 Introduction. 6/5 5TE8 control switches. 6/7 5TE4 8 pushbuttons. 6/9 5TE8 On/Off switches. 6/11 5TE1 switch disconnectors 6/4 Introduction 6/5 5TE8 control switches 6/7 5TE4 8 pushbuttons 6/9 5TE8 On/Off switches 4 6/11 5TE1 switch disconnectors 6 6/1 Switch to manual? Wherever electrical systems need to be switched on or

More information

Overvoltage Protection Devices

Overvoltage Protection Devices Siemens AG 201 /2 Introduction /3 5SD7 lightning arresters, type 1 /5 5SD7 combination surge arresters, type 1 + type 2 /7 5SD7 combination surge arresters, type 1 / type 2 /9 5SD7 surge arresters, type

More information

SENTRON ATC Automatic Transfer Control Device

SENTRON ATC Automatic Transfer Control Device Siemens A 2010 SENTRON - SENTRON switching, protection and measuring devices The SENTRON, when equipped with two motor-driven circuit breakers, serves as a transfer system that automatically or manually

More information

OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) Areas of Application

OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) Areas of Application Miniature Circuit Breakers Areas of Application Miniature circuit breakers (MCBs) of the N-System primarily protect cables and conductors against overload and short circuit. Thus, they also protect electrical

More information

Load Feeders, Motor Starters and Soft Starters

Load Feeders, Motor Starters and Soft Starters Load Feeders, Motor Starters and Soft Starters Catalog Technical Information 3RA Fuseless Compact Starters /2 General data /2 - Overview /3 - Benefits 3RA1, 3RA2 Compact Starters /4 3RA1 direct-on-line

More information

60103 Circuit Breaker

60103 Circuit Breaker 6003 Circuit Breaker United States MINIATURE CIRCUIT BREAKER, 20/240VAC, 2A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Circuit Breaker Type: Standard

More information

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors B Curve NC100H Supplementary Protectors Rating 1P 2P 3P 4P 80 MG27164 MG27175 MG27186 MG27197 MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors C Curve NC100H Supplementary Protectors

More information

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors UL Recognized C60N Supplementary Protectors B Curve C60N Supplementary Protectors 1 MG24110 MG24125 MG24140 MG24155 15 MG17406 MG17436 MG17461 1.2 MG17402 MG17432 16 MG24118 MG24133 MG24148 MG24163 1.5

More information

Leading the Way with 3VA! Compact. Global. Next-Gen! Ryan DeLapp and Fred Myers Manufacturing in America March 14-15, 2018

Leading the Way with 3VA! Compact. Global. Next-Gen! Ryan DeLapp and Fred Myers Manufacturing in America March 14-15, 2018 Leading the Way with 3VA! Compact. Global. Next-Gen! Ryan DeLapp and Fred Myers Manufacturing in America March 14-15, 2018 3VA Agenda Overview 1 2 3 4 Current and Future Releases Product Overview Tools

More information

Siemens AG 2016 SENTRON. 3KC Transfer Switching Equipment up to 3200 A. Edition 10/2016. siemens.com/lowvoltage

Siemens AG 2016 SENTRON. 3KC Transfer Switching Equipment up to 3200 A. Edition 10/2016. siemens.com/lowvoltage SENTRON 3KC Transfer Switching Equipment up to 300 A Edition 10/016 siemens.com/lowvoltage Related catalogs Low-Voltage Power Distribution and LV 10 Electrical Installation Technology SENTRON SIVACON ALPHA

More information

Circuit Breakers, Type CTI 25M, CTI 45MB, CTI 100

Circuit Breakers, Type CTI 25M, CTI 45MB, CTI 100 MAKING MODERN LIVING POSSIBLE Data sheet Circuit Breakers, Type CTI 25M, CTI 45MB, CTI 100 Circuit breakers for short circuit and overload protection of motor applications cover together with the circuit

More information

SACE Emax 2 Specification guide

SACE Emax 2 Specification guide SACE Emax 2 Specification guide Specification Number: 26 01 20.17 Product Name: LOW VOLTAGE POWER CIRCUIT BREAKERS PART 1 GENERAL NOTE: ( ) Indicates option or a selection is to be made for quantity or

More information

Approved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules.

Approved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules. Motor Protection Circuit Breaker (MPCB) J7MN MPCB system (motor protection CLSS 0) Rotary and switch types Rated operational current = 2, 25, 50 and 00 Switching capacity up to 2.5 = 00 k/400 V Fixed short-circuit

More information

Overvoltage Protection Devices

Overvoltage Protection Devices Siemens AG 2010 Overvoltage Protection Devices /2 Introduction /3 Lightning Arresters, Type 1 /5 Combination Surge Arresters, Type 1 and Type 2 /7 Surge Arresters, Type 2 /11 Surge Arresters, Type 3 /12

More information

TeSys IEC Contactors and Overload Relays

TeSys IEC Contactors and Overload Relays TeSys IEC Contactors and Overload Relays Making High-Fault Short-Circuit Current Ratings Simple Schneider Electric is an industry leader in IEC contactors and overload relays, and is recognized as the

More information

Load Feeders and Motor Starters for Use in the Control Cabinet

Load Feeders and Motor Starters for Use in the Control Cabinet Load Feeders and Motor Starters for Use in the Control Cabinet Price groups 12W, 14O, 230, 241, 250, 260, 41B, 41D, 41E, 41L, 42C, 42D, 42F, 471, 4N1, 5K1, 5K2, 5N2, 764, 15, 16 /2 Introduction SIRIUS

More information

3RM1 Hybrid Starters 6SIRIUS. contents. Industrial Controls Product Catalog 2017

3RM1 Hybrid Starters 6SIRIUS. contents. Industrial Controls Product Catalog 2017 3RM1 Hybrid Starters Industrial Controls Product Catalog 2017 Section contents 3RM1 Compact - Hybrid Starters Overview /2 General Data /3 Selection and ordering data /4 Accessories /5 - /9 Technical Data

More information

Industrial Controls Product Catalog RA64 / 3RA65 up to 32 A for mounting rail, surface,

Industrial Controls Product Catalog RA64 / 3RA65 up to 32 A for mounting rail, surface, Combination Starters Industrial Controls Product Catalog 2017 Section c o n t e n t s Self Protected Motor Starters per UL 508 Type E 3RA6 3RA61 / 3RA62 up to 32 A for mounting rail, surface, comb busbar,

More information

4.3. Switchboards. Contents Description Pow-R-Line Drawout Molded Case Circuit Breaker Switchboards Product Selection...

4.3. Switchboards. Contents Description Pow-R-Line Drawout Molded Case Circuit Breaker Switchboards Product Selection... .3 Product Description Drawout molded case circuit breaker switchboard Front accessible Front connected Through-the-door design drawout mechanism through 600A Insulated case UL 89 breakers up to 200A Visual

More information

Circuit Breakers Type CTI 25M, CTI 45MB

Circuit Breakers Type CTI 25M, CTI 45MB Data sheet Circuit Breakers Type CTI 25M, CTI 45MB Circuit breakers for short circuit and overload protection of motor applications cover the current range 0.1 45 A (AC-3 rating). The product range is

More information

NW08 to NW63 fixed circuit breakers Circuit breakers

NW08 to NW63 fixed circuit breakers Circuit breakers fixed circuit breakers Circuit breakers DB404362.eps DB404363.eps A Masterpact fixed circuit breaker is described by 4 catalogue numbers corresponding to: b the basic circuit breaker b a control unit b

More information

Siemens AG Busbar Systems SENTRON. Configuration. Edition Manual. Answers for infrastructure and cities.

Siemens AG Busbar Systems SENTRON. Configuration. Edition Manual. Answers for infrastructure and cities. Busbar Systems SENTRON Configuration Manual Edition 2014 Answers for infrastructure and cities. Busbar Systems 2 Introduction 3 General data 8US 40 mm busbar systems 7 Introduction 8 Basic assemblies

More information

J7MN. Ordering Information. Motor Protection Circuit Breaker. Model Number Legend. MPCB system. Options. Motor Protection Circuit Breaker J7MN I-1

J7MN. Ordering Information. Motor Protection Circuit Breaker. Model Number Legend. MPCB system. Options. Motor Protection Circuit Breaker J7MN I-1 Motor Protection Circuit Breaker J7MN ) MPCB system Rotary and switch types Rated operational current 32 A, 63 A and 00 A Switching capacity up to 00 ka/400 V Fixed short-circuit release = 3 x I u Overload

More information

Monitoring Relays. SIRIUS 3UG Monitoring Relays for Stand-Alone Installation. Line monitoring. 8/62 Siemens IC Overview

Monitoring Relays. SIRIUS 3UG Monitoring Relays for Stand-Alone Installation. Line monitoring. 8/62 Siemens IC Overview Siemens AG 2010 Overview Benefits Can be used without auxiliary voltage in any network from 160 to 600 V AC worldwide thanks to wide voltage range Variably adjustable to overvoltage, undervoltage or range

More information

4 COMBINATION SIRIUS. SIRIUS 3RA6 Compact Starters 4/2. General data

4 COMBINATION SIRIUS. SIRIUS 3RA6 Compact Starters 4/2. General data Combination Starters Industrial Controls Product Catalog 2019 Section contents Self Protected Motor Starters per UL 508 Type E RA6 RA61 / RA62 up to 2 A for mounting rail, surface, comb busbar, infeed

More information

SENTRON. Protective devices Selectivity for 3VA molded case circuit breakers. Introduction. Selectivity - terms and definitions

SENTRON. Protective devices Selectivity for 3VA molded case circuit breakers. Introduction. Selectivity - terms and definitions Introduction 1 Selectivity - terms and definitions 2 SENTRON Methods of implementing selectivity using circuit breakers 3 Protective devices Selectivity for 3VA molded case circuit breakers Configuration

More information

8WH5 Combination Plug-In Terminals

8WH5 Combination Plug-In Terminals 8WH Combination Plug-In Terminals /2 Introduction / 8WH through-type terminals 1) /7 8WH hybrid through-type terminals with ipo connection /8 8WH9 plugs 1) 1) Also available as a PE version More technical

More information

The 3VA molded case circuit breaker.

The 3VA molded case circuit breaker. s Totally Integrated Power SENTRON The 3VA molded case circuit breaker. A complete system designed with you in mind. siemens.com/3va Contents 3VA molded case circuit breaker 04 Power distribution made

More information

sirius Switching. Protecting. Starting. SIRIUS Product Overview

sirius Switching. Protecting. Starting. SIRIUS Product Overview sirius Switching. Protecting. Starting. SIRIUS Product Overview S00 Design Direct-on-line starting Reversing duty Assembly kit for busbar mounting 0 mm: RA9 -C 0 mm: RA9 -D Consisting of: wiring kit busbar

More information

SIMOCODE 3UF Motor Management and Control Devices

SIMOCODE 3UF Motor Management and Control Devices Technical specifications General data applicable to the basic units, current measuring modules, current/voltage measuring modules, expansion modules, decoupling module and operator panel Permissible ambient

More information

IZMX series Air Circuit Breakers with Power Xpert Releases PXR

IZMX series Air Circuit Breakers with Power Xpert Releases PXR IZMX series Air Circuit Breakers with Power Xpert Releases PXR Australia and New Zealand The new series IZMX16/IZMX40 Small, flexible & fully loaded Versatile circuit breakers up to 4000A for cost-effective,

More information

Close Protection from Moeller. miniature branch circuit breakers miniature supplementary protectors

Close Protection from Moeller. miniature branch circuit breakers miniature supplementary protectors Close Protection from Moeller miniature branch circuit breakers miniature supplementary protectors FAZ branch circuit breakers General Information... Selection Tables Trip Characteristic C - Box terminals...

More information

For Efficiency and Reliability in the Control Cabinet. The SIRIUS 3RA6 Compact Starter SIRIUS. Answers for industry.

For Efficiency and Reliability in the Control Cabinet. The SIRIUS 3RA6 Compact Starter SIRIUS. Answers for industry. For Efficiency and Reliability in the Control Cabinet The SIRIUS 3RA6 Compact Starter SIRIUS Answers for industry. Highlights Space savings in the control cabinet, thanks to compact design Minimized engineering,

More information

Overvoltage Protection Devices

Overvoltage Protection Devices Siemens AG 2014 Overvoltage Protection Devices /2 Introduction /3 5SD7 lightning arresters, type 1 /5 5SD7 combination surge arresters, type 1 and type 2 /7 5SD7 combination surge arresters, type 1 / type

More information

UL 489 DIN Rail Miniature Circuit Breakers

UL 489 DIN Rail Miniature Circuit Breakers UL 489 DIN Rail Miniature Circuit Breakers Product Overview................................................ 2 Product Selection................................................ 4 Accessories.....................................................

More information

SIEMENS AG For Efficiency and Reliability in the Control Cabinet. The SIRIUS 3RA6 Compact Starter SIRIUS. Answers for industry.

SIEMENS AG For Efficiency and Reliability in the Control Cabinet. The SIRIUS 3RA6 Compact Starter SIRIUS. Answers for industry. For Efficiency and Reliability in the Control Cabinet The SIRIUS 3RA6 Compact Starter SIRIUS Answers for industry. Highlights Space savings in the control cabinet, thanks to compact design Minimized engineering,

More information

Motors Automation Energy Transmission & Distribution Coatings. DWB Molded Case Circuit Breakers DWB

Motors Automation Energy Transmission & Distribution Coatings. DWB Molded Case Circuit Breakers DWB Motors Automation Energy Transmission & Distribution Coatings DWB Molded Case Circuit Breakers DWB Molded Case Circuit Breakers Molded Case Circuit Breakers DWB Summary Presentation 0 General Characteristics

More information

SITOP in the SIMATIC Design

SITOP in the SIMATIC Design Siemens AG 2017 /2 Introduction /3 1-phase, 24 V DC (for S7-300 and ET 200M) /9 1-phase, 24 V DC (for S7-1200) /11 1-phase, 24 V DC (for S7-1500 and ET 200MP) /14 3-phase, 24 V DC (ET 200pro) Siemens KT

More information

UL 489 DIN Rail Miniature Circuit Breakers

UL 489 DIN Rail Miniature Circuit Breakers UL 9 DIN Rail Miniature Circuit Breakers Product Overview................................................ Product Selection................................................ Accessories.....................................................

More information

powerful ideas RELIABLE SOLUTIONS ANSI / UL1066 & UL 489 WL Low Voltage Power Circuit Breaker WL Trip Unit, MODBUS Communication

powerful ideas RELIABLE SOLUTIONS ANSI / UL1066 & UL 489 WL Low Voltage Power Circuit Breaker WL Trip Unit, MODBUS Communication 1/28/05 1:20 PM Page 1 Order # CBTA-01000-1004 New 5M105CEG Printed in USA 2005 Siemens Energy & Automation, Inc. All Rights Reserved Siemens is a registered trademark of Siemens AG. Product names mentioned

More information

SENTRON SIVACON ALPHA

SENTRON SIVACON ALPHA SENTRON SIVACON ALPHA Low-Voltage Power Distribution and Electrical Installation Technology Catalog Extract LV 10 Edition 10/2018 siemens.com/lowvoltage Related catalogs Low-Voltage Power Distribution

More information

low voltage GLOBAL CATALOGUE RANGE Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters

low voltage GLOBAL CATALOGUE RANGE Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters CTLOGUE GLOBL RNGE 2. Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters 2. 2. Product Overview. 2.2 Overload Relay Setting Range 2. - 2.8 Product Specifications 2.9-2. Contactor

More information

Miniature Circuit Breakers and Supplementary Protectors. Contents

Miniature Circuit Breakers and Supplementary Protectors. Contents . Optimum and Efficient Protection for Every Application Product Overview Features Optimum product quality, tested reliability and safety stand for best protection of personnel, installations and plant.

More information

MOTOR PROTECTION CIRCUIT BREAKERS

MOTOR PROTECTION CIRCUIT BREAKERS MOTOR PROTECTION CIRCUIT BREAKERS PAGE -2 PAGE -2 SMA Thermal trip adjustment ranges 9-32A (5 choices) Breaking capacity Icu at 400V: 50kA Suitable for mounting in consumer switchboards with minimum 58mm

More information

Siprotec 7ST61 / 7ST63

Siprotec 7ST61 / 7ST63 Siprotec / Numerical overhead contact line protection for AC traction power supply siemens.de/rail-electrification The numerical overhead contact line protection relay Siprotec / is a selective and quick

More information

Residual Current Devices drcm Digital

Residual Current Devices drcm Digital Digital Line voltage independent RCCB for fault or additional protection with additional digital features. System Monitoring: Preventive information / warning before the RCD trips in case of leakage currents.

More information

.2 Section General Commissioning (Cx) Requirements. .3 Section Common Work Requirements - Electrical

.2 Section General Commissioning (Cx) Requirements. .3 Section Common Work Requirements - Electrical Issued for Review Section 26 28 16.01 Air Circuit Breakers Page 1 of 7 PART 1 GENERAL 1.1 GENERAL.1 This specification serves to define requirements for a replacement of low voltage circuit breaker of

More information

UL 489 Cable-In / Cable-Out Branch Circuit Breaker

UL 489 Cable-In / Cable-Out Branch Circuit Breaker Product Overview UL 9 Cable-In / Cable-Out Branch Circuit Breaker PRODUCT OVERVIEW Optimum and Efficient Protection Features Complete range of UL 9 listed DIN rail mounted miniature circuit breakers up

More information

////// SUBSTATIONS. DC Switchgear Range. Type MBS (IEEE/ANSI standards)

////// SUBSTATIONS. DC Switchgear Range. Type MBS (IEEE/ANSI standards) ////// SUBSTATIONS DC Switchgear Range Type MBS (IEEE/ANSI standards) GENERAL INFORMATION With a complete range of equipment and a leading expertise in DC traction power substations, Sécheron SA is a world

More information

SIGUARD Safety Combinations and Safe Load Feeders. safety INTEGRATED

SIGUARD Safety Combinations and Safe Load Feeders. safety INTEGRATED SIGUARD Safety Combinations and Safe Load Feeders safety INTEGRATED EMERGENCY Topmost priority protection of man, machine and the environment The topmost priority is to protect man, machine and the environment

More information

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064 Monitoring technique VARIMETER Voltage relay MK 9064N, MH 9064 0269462 Your Advantages Preventive maintenance For better productivity Quicker fault locating Precise and reliable Min-, Max. value or window

More information

Monitoring Devices. 12/2 Introduction. Transfer switches 12/5 3KC ATC5300 transfer control device

Monitoring Devices. 12/2 Introduction. Transfer switches 12/5 3KC ATC5300 transfer control device Siemens AG 20 Monitoring Devices /2 Introduction Transfer switches /5 3KC ATC5300 transfer control device Monitoring devices for electrical values /9 5SV8 residual current monitors /11 5TT3 voltage relays

More information

Contactors and Contactor Assemblies

Contactors and Contactor Assemblies RT contactors, size S00 The product range at a glance The new generation is a complete, modular system family, logically designed right down to the last detail, from the basic units to the accessories.

More information

Approved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules.

Approved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules. Motor Protection Circuit Breaker (MPCB) J7MN MPCB system (motor protection CLSS 0) Rotary and switch types Rated operational current = 2, 25, 50 and 00 Switching capacity up to 2.5 = 00 k/400 V Fixed short-circuit

More information

1.2. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZ Circuit Breaker. UL 489 DIN Rail Miniature Circuit Breakers

1.2. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZ Circuit Breaker. UL 489 DIN Rail Miniature Circuit Breakers .2 WMZ Circuit Breakers Contents Description WMZ Circuit Breaker Standards and Certifications.............. Selection................ Product Selection....................... Accessories...........................

More information

AThink future. Switch to green. Mini Panel Board. Cost-effective, space-saving board up to 400A.

AThink future. Switch to green. Mini Panel Board. Cost-effective, space-saving board up to 400A. www.moeller.co.uk Mini Panel Board Cost-effective, space-saving board up to 400A Product Catalogue and Selection Guide Mini Panel Board Miniature Circuit Breakers Moulded Case Circuit Breakers XBoard Consumer

More information

3RV1 Circuit-Breakers

3RV1 Circuit-Breakers SIRIUS 3R Description Mountable accessories 3RV1 Circuit- Breakers Circuit-breaker S00 with mountable accessories 3 2 1 5.1 NSK-7715a 4 Circuit-breaker S0 with mountable accessories 1 7 3 5.2 2 6 NSK-7716a

More information

PGR-6101 MANUAL GROUND-FAULT & INSULATION MONITOR

PGR-6101 MANUAL GROUND-FAULT & INSULATION MONITOR Tel: +1-800-832-3873 E-mail: techline@littelfuse.com www.littelfuse.com PGR-6101 MANUAL GROUND-FAULT & INSULATION MONITOR Revision 0-C-041918 Copyright 2018 by Littelfuse, Inc. All rights reserved. Document

More information

Lightning and Surge Arresters

Lightning and Surge Arresters Lightning and Surge Arresters 5/4 Product overview 5/5 Lightning arresters, requirement category I (B) 5/6 Combined arresters, requirement category I (B) and II (C) 5/7 Single-pole surge arrester, requirement

More information

Overload Relays. 3RB2 Solid-State Overload Relays. 3RB20, 3RB21 for standard applications. 5/48 Siemens LV Overview

Overload Relays. 3RB2 Solid-State Overload Relays. 3RB20, 3RB21 for standard applications. 5/48 Siemens LV Overview Overload Relays Siemens AG 2009 Overview 1 2 2 (1)Connection for mounting onto contactors: Optimally adapted in electrical, mechanical and design terms to the contactors and soft starters, these connecting

More information

454 PHOENIX CONTACT Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA

454 PHOENIX CONTACT Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 454 PHOENIX CONTACT and feed-through terminal blocks The more varied the tasks in electrical engineering, the more varied the components for the solution have to be. The industrial connection technology

More information

Alberto Carini, LPLS Italy, June 2013 MNS is The Intelligent MCC. ABB Group June 21, 2013 Slide 1

Alberto Carini, LPLS Italy, June 2013 MNS is The Intelligent MCC. ABB Group June 21, 2013 Slide 1 Alberto Carini, LPLS Italy, June 2013 MNS is The Intelligent MCC June 21, 2013 Slide 1 The MCC evolution Traditional MCC Intelligent relays MCC with integrated intelligence June 21, 2013 Slide 2 The intelligent

More information

Miniature Circuit Breakers for Railway Applications

Miniature Circuit Breakers for Railway Applications Siemens AG 00 for Railway Applications BETA Low-Voltage Circuit Protection The miniature circuit breakers are used in fixed railway systems and rolling stock for protecting system components against overcurrent

More information

Description. Monitoring functions Evaluation of brush length monitoring, digital, non-floating A00

Description. Monitoring functions Evaluation of brush length monitoring, digital, non-floating A00 Monitoring functions Evaluation of brush length monitoring, digital, non-floating Evaluation of brush length monitoring, digital, floating A00 A06 Non-floating brush length monitoring with use of KM01

More information

Solid-State Contactors

Solid-State Contactors Solid-state contactors for switching motors The solid-state contactors for switching motors are intended for frequently switching on and off three-phase current operating mechanisms up to 7.5 kw and reversing

More information

Monitoring Technique. VARIMETER PRO Multifunction Measuring Relay MK 9300N, MH 9300

Monitoring Technique. VARIMETER PRO Multifunction Measuring Relay MK 9300N, MH 9300 Monitoring Technique VARIMETER PRO Multifunction Measuring Relay MK 93N, MH 93 268581 Product description MK 93N MH 93 The universal measuring relays MK 93N / MH 93 of the VARIMETER PRO series monitor

More information

SIRCO Load break switches for power distribution from 125 to 5000 A

SIRCO Load break switches for power distribution from 125 to 5000 A The solution for Load break switches sirco_456_a_1_cat > Main switchboard > Distribution panel > Emergency breaking > Network coupling > Local safety breaking sirco-ac_001_a_1_cat SIRCO 3 x 250 A direct

More information

1.3. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZS Circuit Breaker. UL 1077 DIN Rail Supplementary Protectors

1.3. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZS Circuit Breaker. UL 1077 DIN Rail Supplementary Protectors . Miniature Circuit Breakers and Supplementary Protectors UL 077 DIN Rail Supplementary Protectors WMZS Circuit Breakers Contents Description WMZS Circuit Breaker Standards and Certifications................

More information

Miniature Circuit-Breaker IEC Series 8562

Miniature Circuit-Breaker IEC Series 8562 > 1 to 3 pole versions > Rated current from 0.5... 40 A > 6 or 10 ka breaking capacity to DI VDE 0641, respectively E 60898 > Isolating Function to E 60947-2 > Permanently set thermal and magnetic trips

More information

3RA13, 3RA14 Contactor Assemblies

3RA13, 3RA14 Contactor Assemblies RA1, RA Contactor Assemblies RA1 complete units,... kw Overview The RA1 reversing contactor assemblies can be ordered as follows: Sizes S00 to S Fully wired and tested, with mechanical and electrical interlock

More information

IZMX Series Air Circuit Breakers. Small, flexible, efficient

IZMX Series Air Circuit Breakers. Small, flexible, efficient IZMX Series Air Circuit Breakers Small, flexible, efficient Versatile circuit breakers up to 4000 A for cost-effective, optimized solutions. The IZMX16 of the NRX series is the smallest air circuitbreaker

More information

Residual Current Devices. Residual Current Devices FRCmM-NA according to UL1053 & IEC/EN 61008

Residual Current Devices. Residual Current Devices FRCmM-NA according to UL1053 & IEC/EN 61008 Residual Current Devices FRCmM-NA according to UL1053 & IEC/EN 61008 Wide range of compact types of RCDs serving as fault-current and additional protection according to UL1053 & IEC/EN 61008 standards,

More information

Solid-State Switching Devices

Solid-State Switching Devices Controls Solid-State Switching Devices /2 Introduction Solid-State Switching Devices /3 General data Solid-State Switching Devices for Resistive Loads /5 General data Solid-State Relays /7 General data

More information