3U RACK SHELF 19 INCH 3U GEAR RACK SHELF FOR CV AND PIXIE DRIVERS

Size: px
Start display at page:

Download "3U RACK SHELF 19 INCH 3U GEAR RACK SHELF FOR CV AND PIXIE DRIVERS"

Transcription

1 ! DO NOT ATTEMPT TO INSTALL OR USE A PRODUCT UNTIL YOU HAVE READ AND UNDERSTAND THE USER MANUAL AND SAFETY LABELS.! 3U RACK SHELF 19 INCH 3U GEAR RACK SHELF FOR CV AND PIXIE DRIVERS P 1/7

2 ! DO NOT ATTEMPT TO INSTALL OR USE A PRODUCT UNTIL YOU HAVE READ AND UNDERSTOOD THE USER MANUAL AND SAFETY LABELS.! PRODUCT DESCRIPTION THIS PRODUCT IS USED TO HOUSE THE CV DRIVER OR PIXIE DRIVER. THE PURPOSE IS TO CONVENIENTLY MOUNT MULTIPLE PRODUCTS WITHIN THE ONE RACK MOUNTED SHELF. THE SHELF IS DESIGNED FOR USE WITHIN A 19 INCH GEAR RACK, IT COULD OTHERWISE BE USED IN A CUSTOM BUILT RACK/ MOUNTING SYSTEM. THE PRODUCT OCCUPIES 3 RACK UNITS. ORDER CODES THERMAL MANAGEMENT CODE DESCRIPTION x CV DRIVER, 3U 19 RACK SHELF (230VAC) x CV DRIVER, 3U 19 RACK SHELF (115VAC) x PIXIE DRIVER, 3U 19 RACK SHELF (230VAC) x PIXIE DRIVER, 3U 19 RACK SHELF (115VAC) THE 3U RACK SHELF MUST BE RECEIVING POWER DURING OPERATION AND THE FANS MUST BE OPERATIONAL. IF THE FANS ARE NOT OPERATING THE PRODUCTS HOUSED WILL OVERHEAT RESULTING IN PRODUCT FAILURE. DO NOT OBSTRUCT FANS, DO NOT INSTALL THE PRODUCT IN AN AREA RESTRICTING AIR FLOW. ISOMETRIC IN SITU BOX CONTENTS 1 x 3U RACK SHELF 4 x BLANKING PLATES (WITH SCREWS) 1 x USER MANUAL 2 x RACK EARS (WITH SCREWS) /230 ALSO INCLUDES 8 x PIXIE DRIVER ADAPTATION PLATE DOES NOT INCLUDE POWER PLUG OR RACK MOUNT SCREWS. PACKAGING MATERIAL SIZE VOLUME SHIPPED WEIGHT RECYCLABLE CARDBOARD H: 154mm, W: 410mm, L: 460mm H: 6.0in, W: 15.8in, L: 18.1in m³, 1.01 ft³ 8.5 kg, 18.7 lbs P 2/7

3 DIMENSIONS RU R TO SUIT A 19 INCH RACK FAN VENTS P 3/7

4 3U RACK SHELF TECHNICAL DATA PRODUCT CODE INPUT VOLTAGE 115 VOLTS 230 VOLTS 115 VOLTS 230 VOLTS INPUT FREQUENCY 50/60 Hz POWER 24 WATTS WEIGHT 7.5 kg, 16.5 lbs AMBIENT OPERATING AMBIENT STORAGE -10 ~ 70 C, 14 ~ 158 F, NON CONDENSING ENVIRONMENT (DOES NOT APPLY TO HOUSED PRODUCTS) -40 ~ +70 C, -40 ~ 158 F, NON CONDENSING ENVIRONMENT WARRANTY 3 YEARS RACK UNITS 3 RACK UNITS THERMAL MANAGEMENT ACTIVE (FAN COOLED) TOTAL FAN NOISE 35dB FAN LIFETIME AT TEMP 50, C INGRESS PROTECTION IP20 BLANKING PLATE CONFIGURATIONS BLANKING PLATES WILL SUIT ANY CONFIGURATION FROM 1-8 DRIVERS. BELOW THE RACK IS PICTURED MOUNTING THE PIXIE DRIVER. BLANK PLATE 1 P 4/7 BLANK PLATE 2 BLANK PLATE 3 BLANK PLATE 4

5 CONSTRUCTION DETAILS MATERIAL COATING MAIN COLOUR FASTENERS CARBON STEEL POLYESTER (POWDERCOAT) BLACK TEXTURE ZINC PLATED MECHANICAL ASSEMBLY BLANKING PLATES AND RACK EARS ARE SUPPLIED LOOSE, ASSEMBLY WILL BE REQUIRED TOOLS REQUIRED NO.02 PHILLIPS HEAD SCREWDRIVER RACK EARS BLANKING PLATES X 6 SCREWS PER RACK EAR P 5/7

6 RACK MOUNT ENTTEC RECOMMENDS INSTALLING THE 3U RACK SHELF IN THE RACK PRIOR TO LOADING THE SHELF WITH THE DRIVERS. REMOVE FRONT BAR IN ORDER TO SLIDE DRIVERS INTO SHELF PIXIE DRIVER INSTALLATION PIXIE ADAPTATION PLATE PIXIE DRIVER FRONT BAR P 6/7

7 CV DRIVER INSTALLATION P 7/7

DMC-1000 Chassis-Based Media Converter

DMC-1000 Chassis-Based Media Converter DMC-1000 Chassis-Based Media Converter User s Guide Rev. 01 (Jan. 2002) 6012-9600131 (1907MCR11616000) Printed In Taiwan RECYCLABLE i TABLE OF CONTENTS TABLE OF CONTENTS... II PREFACE... 3 19 MEDIA CONVERTER

More information

Programmable Controller IC697ACC721/724/744

Programmable Controller IC697ACC721/724/744 GFK-0637H April 2003 Features Provides additional rack cooling Three fans per assembly Easy installation 120 VAC, 240 VAC, or 24 VDC models Used with 9-slot IC697 standard racks, 17-slot IC697 VME Integrator

More information

OV-MCR116. Media Converter Chassis System. User s Manual

OV-MCR116. Media Converter Chassis System. User s Manual OV-MCR116 Media Converter Chassis System User s Manual FCC Class B Certification This equipment has been tested and found to comply with the regulations for a Class B digital device, pursuant to Part 15

More information

Junos WebApp Secure 5.0 Hardware Guide

Junos WebApp Secure 5.0 Hardware Guide Junos WebApp Secure 5.0 Hardware Guide Junos WebApp Secure 5.0 Hardware Guide This document contains a specification for the MWS1000 hardware appliance, as well as instructions for installation into a

More information

Electric Window Actuators. Conel Stand Alone Window Operator 126 Conel Keypad Window Operator 128

Electric Window Actuators. Conel Stand Alone Window Operator 126 Conel Keypad Window Operator 128 Electric Window Actuators Conel Stand Alone Window Operator 126 Conel Keypad Window Operator 128 125 Conel Stand Alone Window Operator General Information Opening and closing multiple sashes to optimise

More information

TABLE OF CONTENTS 1. OVERVIEW... 1

TABLE OF CONTENTS 1. OVERVIEW... 1 TABLE OF CONTENTS 1. OVERVIEW... 1 1.1. SPECIFICATIONS... 1 1.1.1. Electrical... 1 1.1.2. Compliance... 2 1.1.3. Physical... 2 1.2. COOLING... 2 1.2.1. Fan Exhaust... 2 1.3. MOUNTING... 3 1.4. POWER...

More information

Safety. Features 1 ID: Make all the connections before you plug in the main power. DMX512 Controllable and RDM Configurable

Safety. Features 1 ID: Make all the connections before you plug in the main power. DMX512 Controllable and RDM Configurable Features DMX512 Controllable and RDM Configurable Designed for driving LED strips through 6 high power 12 and 24 Volts output units available Easy addressing interface (physical switches and RDM) Isolated

More information

Dell Networking S4810 Open Networking (ON) Getting Started Guide

Dell Networking S4810 Open Networking (ON) Getting Started Guide Dell Networking S4810 Open Networking (ON) Getting Started Guide Regulatory Model: S4810 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your

More information

PRELIMINARY. CR Series. Ceiling Rack Systems with AmbiTILT Equipment Loading

PRELIMINARY. CR Series. Ceiling Rack Systems with AmbiTILT Equipment Loading 1/6 CR Series Ceiling Rack Systems with AmbiTILT Equipment Loading General Description AtlasIED, the manufacturing leader of ceiling mounted loudspeakers introduces the new CR Series ceiling-mounted equipment

More information

PHOS 20/40 downlight OWNER'S MANUAL

PHOS 20/40 downlight OWNER'S MANUAL PHOS 20/40 downlight OWNER'S MANUAL TABLE OF CONTENTS Safety Instructions...4 Electrical Safety... 4 Lamp Safety...4 Burns and Fire Safety... 5 Safety During Installation And Operation... 5 Technical Overview...

More information

iconverter 2-Module Power Chassis

iconverter 2-Module Power Chassis iconverter 2-Module Power Chassis User Manual 38 Tesla, Irvine, CA 92618 USA Phone: (949) 250-6510; Fax: (949) 250-6514 Page 1 Warning The operating description in this Instruction Manual is for use by

More information

Chapter 2 BladeStation Enclosure

Chapter 2 BladeStation Enclosure Chapter 2 BladeStation Enclosure Cubix BladeStation is an enclosure that provides power and cooling to multiple Cubix Blade Servers. It consists of a steel case, a mid-plane, an Input / Output (I / O)

More information

ANT CNTR DC ALRM LNB RX DC ALRM +18V OFF

ANT CNTR DC ALRM LNB RX DC ALRM +18V OFF Instruction Manual Model 2082-1972 Power Supply July 2012, Rev. B MODEL 2082 POWER SUPPLY CROSS TECHNOLOGIES INC. PRIMARY PWR AC BUC +48V AUX BUC TX SELECT 48V +18V/48V LNB RX +18V ANT CNTR +29V AC 18V

More information

TRC-190 User s Manual

TRC-190 User s Manual User s Manual Edition 3.2, May 2017 www.moxa.com/product 2017 Moxa Inc. All rights reserved. User s Manual The software described in this manual is furnished under a license agreement and may be used only

More information

CVH Slot Media Converter Chassis Quick Installation Guide

CVH Slot Media Converter Chassis Quick Installation Guide CVH-2000 14-Slot Media Converter Chassis Quick Installation Guide Ver. 1.2-1305 Table of Contents 1. INTRODUCTION... 1 1.1. FEATURES... 1 1.2. PACKAGE CONTENTS... 1 2. HARDWARE DESCRIPTION... 2 REAL PANEL...

More information

PMCL Series Mounts RACK/CEILING/WALL MOUNTS, UNIVERSAL CAMERA MOUNT, MONITORS

PMCL Series Mounts RACK/CEILING/WALL MOUNTS, UNIVERSAL CAMERA MOUNT, MONITORS PRODUCT SPECIFICATION control site PMCL Series Mounts RACK/CEILING/WALL MOUNTS, UNIVERSAL CAMERA MOUNT, MONITORS Product Features For Use with VESA -Compliant Monitors Rack Mounts for All 200/300/400 Series

More information

Installation Job Aid for VSP 4850GTS

Installation Job Aid for VSP 4850GTS Installation Job Aid for VSP 4850GTS Notices Release 6.1.0.0 NN46251-308 Issue 02.01 November 2017 Notice paragraphs alert you about issues that require your attention. The following paragraphs describe

More information

OmniSmart 1500VA 2U Rack/Tower Line-Interactive 120V UPS with LCD display and USB port

OmniSmart 1500VA 2U Rack/Tower Line-Interactive 120V UPS with LCD display and USB port OmniSmart 1500VA 2U Rack/Tower Line-Interactive 120V UPS with LCD display and USB port MODEL NUMBER: OMNI1500LCD Highlights 1500VA / 1.5kVA 2U rack/tower 120V line interactive UPS with LCD display Corrects

More information

Savant Call Server: SCS-3000

Savant Call Server: SCS-3000 The Savant Call Server (SCS-3000) is a key communications building block in a Savant system. The Savant Call Server allows you to make panel-topanel calls from any intercom-ready ios devices (iphone, ipod

More information

Sapling Converter Box

Sapling Converter Box Installation Manual Sapling Converter Box SCB-100-000-1 Version Number 1.2 Current as of March 15, 2015 The Sapling Company, Inc. (+1) 215.322.6063 P. (+1) 215.322.8498 F. 2-Wire Converter Box (SCB-100-000-1)

More information

EIA 310-D. RAL 9005 black textured, low-gloss polyester powder paint over pretreated steel.

EIA 310-D. RAL 9005 black textured, low-gloss polyester powder paint over pretreated steel. 763.422.2588 Spec-00525 M763.422.2661 Free-Stand Cabinets PROLine Network s Free-Stand Cabinets PROLINE Network s PROLINE Network INDUSTRY StandardS EIA 310-D APPLICATION PROLINE Network Switch cabinet

More information

MAJOR VA Power Inverter

MAJOR VA Power Inverter MAJOR500-500 VA Power Inverter The Major500 is a highly reliable, telecom quality, DC to AC power inverter. The Major500 features full electronic protection, high efficiency and low output noise. The built-in

More information

Installing the Cisco MDS 9020 Fabric Switch

Installing the Cisco MDS 9020 Fabric Switch CHAPTER 2 This chapter describes how to install the Cisco MDS 9020 Fabric Switch and its components, and it includes the following information: Pre-Installation, page 2-2 Installing the Switch in a Cabinet

More information

SmartPro LCD 120V 1.5kVA 900W Line-Interactive UPS, AVR, 2U Rack/Tower, LCD Display, USB, DB9 Serial

SmartPro LCD 120V 1.5kVA 900W Line-Interactive UPS, AVR, 2U Rack/Tower, LCD Display, USB, DB9 Serial SmartPro LCD 120V 1.5kVA 900W Line-Interactive UPS, AVR, 2U Rack/Tower, LCD Display, USB, DB9 Serial MODEL NUMBER: SMART1500LCD Highlights 1500VA / 1.5kVA 2U rack/tower 120V line interactive UPS with LCD

More information

300 - SERIES NETWORK SWITCHES QUICK START GUIDE

300 - SERIES NETWORK SWITCHES QUICK START GUIDE 300 - SERIES NETWORK SWITCHES QUICK START GUIDE Managed IT Rack Network Switches FCC Warning This device has been tested and found to comply with limits for a Class A digital device, pursuant to Part 15

More information

Installation Job Aid for Ethernet Routing Switch 3600 Series

Installation Job Aid for Ethernet Routing Switch 3600 Series Installation Job Aid for Ethernet Routing Switch 3600 Series Notices NN47213-303 Issue 03.01 November 2017 Notice paragraphs alert you about issues that require your attention. Following are descriptions

More information

MPP1700 User s Manual

MPP1700 User s Manual 2011 Visionary Solutions, Inc. All rights reserved. Please visit the support section of our website at www.vsicam.com for manuals, other documentation, and software downloads. Visionary Solutions, Inc.

More information

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual Omnitron Systems Technology, Inc. 1 iconverter 19-Module Managed Power Chassis User s Manual 27 Mauchly, #201, Irvine, CA 92618 Phone: (949) 250-6510; Fax: (949) 250-6514 2 Omnitron Systems Technology,

More information

ACCESSORIES POWER & INFRASTRUCTURE SOLUTIONS

ACCESSORIES POWER & INFRASTRUCTURE SOLUTIONS ACCESSORIES POWER & INFRASTRUCTURE SOLUTIONS MILESTONE.COM POWER & INFRASTRUCTURE SOLUTIONS PROTECT YOUR INSTALL WITH CHIEF INFRASTRUCTURE ACCESSORIES, NOW WITH POWER & SURGE Chief engineers design every

More information

CSR-G6300 6U Rack Chassis. CSR-G3300 3U Rack Chassis. Operation Manual

CSR-G6300 6U Rack Chassis. CSR-G3300 3U Rack Chassis. Operation Manual CSR-G6300 6U Rack Chassis CSR-G3300 3U Rack Chassis Operation Manual DISCLAIMERS The information in this manual has been carefully checked and is believed to be accurate. Cypress Technology assumes no

More information

PROLINE ExtERNal ComPONENts. PROLINE tops and Bases

PROLINE ExtERNal ComPONENts. PROLINE tops and Bases Spec-00428 E763.422.2211 763.422.2600 PROLINE ExtERNal ComPONENts PROLINE Tops and Bases PROLINE ExtERNal ComPONENts PROLINE tops and Bases Solid tops Solid Tops are used to close the top opening on an

More information

STATUS Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

STATUS Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free Instruction Manual Model 1582-45L Data Switch September 2010, Rev A REMOTE LOCAL SWITCH STATUS SELECT REMOTE LOCAL LOCAL SELECT CHANNEL SELECT POWER MODEL 1582 SWITCH CROSS TECHNOLOGIES, INC. Data, drawings,

More information

E1135C PDU and Pod Upgrade Procedure

E1135C PDU and Pod Upgrade Procedure E4030-90010 Rev. B 12/2003 In this Document... Tools Needed, 2 Contents of the Upgrade Kits, 2 Installation Procedures, 4 Verifying the Power Option of the New PDU, 4 Removing the PDU from the Support

More information

Power-Over-Ethernet (PoE) Weatherproof 14 x12 x7 Enclosure with Mounting Plate and Cooling Fan. Model: NB F. Applications and Features

Power-Over-Ethernet (PoE) Weatherproof 14 x12 x7 Enclosure with Mounting Plate and Cooling Fan. Model: NB F. Applications and Features Power-Over-Ethernet (PoE) Weatherproof 14 x12 x7 Mounting Plate and Cooling Fan Model: NB141207-40F Applications and Features Applications: Remote Wireless LAN WiFi equipment installations using Power-Over-

More information

LW Datasheet. Temperature

LW Datasheet. Temperature LW LW Large Industrial Display DYNICS LW is a versatile display, designed to be a monitor or integrated with a sealed XiS PC. The LW is housed in a fan-less, drip-proof enclosure, able to operate 24/7

More information

Model #: SU1500RTXL2U

Model #: SU1500RTXL2U Tripp Lite 1111 West 35th Street Chicago, IL 60609 USA Telephone: +(773) 869 1234 E-mail: saleshelp@tripplite.com Model #: SU1500RTXL2U Smart Online Expandable Rack/Tower UPS System - Online, double-conversion

More information

FMP VDC RECTIFIER 42 Amps 2000 Watts

FMP VDC RECTIFIER 42 Amps 2000 Watts FMP20.48 48VDC RECTIFIER 42 Amps 2000 Watts DESCRIPTION The FMP20.48 rectifier incorporates resonant technology to reduce component stresses and provide increased system reliability. The rectifier features

More information

FVT Slot Media Converter Chassis w/ Redundant Power User Manual

FVT Slot Media Converter Chassis w/ Redundant Power User Manual FVT-4000 10-Slot Media Converter Chassis w/ Redundant Power User Manual Ver. 1.00-0609 Table of Contents 1. INTRODUCTION... 1 1.1. FEATURES... 1 1.2. PACKAGE CONTENTS... 2 2. HARDWARE DESCRIPTION... 3

More information

Product data sheet : Electric height adjustable desk frame

Product data sheet : Electric height adjustable desk frame Product data sheet : Electric height adjustable desk frame 501-27 327990.2 Table of contents Packing details.... 3 Main measures and specifications.... 4 Tabletop drillings.... 5 Assembly and use... 6

More information

Dell SC460 Expansion Enclosure Getting Started Guide

Dell SC460 Expansion Enclosure Getting Started Guide Dell SC460 Expansion Enclosure Getting Started Guide Regulatory Model: CYAE Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION:

More information

PHOS mini OPERATING INSTRUCTIONS

PHOS mini OPERATING INSTRUCTIONS PHOS mini OPERATING INSTRUCTIONS TABLE OF CONTENTS Safety Instructions...4 Electrical Safety... 4 Burns and Fire Safety... 5 Lamp Safety...5 Safety during installation and operation... 6 Technical Overview

More information

Specifications XPA 2002, XPA 2003, XPA 2004 Series

Specifications XPA 2002, XPA 2003, XPA 2004 Series Specifications XPA 2002, XPA 2003, XPA 2004 Series Audio Voltage gain XPA 2002, XPA 2004... 23x (27 db) /100V (ch. 1 and 2) 23x (27 db) XPA 2002-70V, (ch. 3 only) 57x (35 db) XPA 2002-100V, (ch. 3 only)

More information

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS MAINTENANCE MANUAL EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS SPECIFICATIONS*... 2 INTRODUCTION... 3 DESCRIPTION...

More information

Dell MD1280 Storage Enclosure Getting Started Guide

Dell MD1280 Storage Enclosure Getting Started Guide Dell MD1280 Storage Enclosure Getting Started Guide Regulatory Model: SP-2584, E11J Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer.

More information

MCFCW-20-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 60,000 BTUH

MCFCW-20-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 60,000 BTUH MCFCW-20-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 60,000 BTUH 1 Chilled and Hot Water Fan Coil High Static 4-Pipe Nominal

More information

1. Move the cardboard carton close to the installation site, making sure you have adequate space to remove all the contents of the box.

1. Move the cardboard carton close to the installation site, making sure you have adequate space to remove all the contents of the box. Install the vedge 1000 Router Once you have prepared your site for router installation, unpack the vedge 1000 router. If you plan to install the router in a 19-inch rack, unpack the rack-mount kit as well

More information

MCFCW-08-4LS-1 (4-Pipe) Low Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 24,000 BTUH

MCFCW-08-4LS-1 (4-Pipe) Low Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 24,000 BTUH MCFCW-08-4LS-1 (4-Pipe) Low Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 24,000 BTUH 1 Chilled and Hot Water Fan Coil Low Static 4-Pipe Nominal Size:

More information

Installing the Cisco SFS 3504 Server Switch

Installing the Cisco SFS 3504 Server Switch CHAPTER 3 This chapter describes how to mount your Cisco SFS 3504 Server Switch on a rack, boot the Cisco SFS 3504 Server Switch, and configure basic services. For advanced configuration information, see

More information

HIGH DENSITY TERMINAL BLOCKS

HIGH DENSITY TERMINAL BLOCKS CONTROL LOGIC HIGH DENSITY TERMINAL BLOCKS c3controls new line of High Density terminal blocks are both innovative and user-friendly. Available in multiple terminal points from 4, 6, and 12 in a single

More information

MCFCW-06-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 18,000 BTUH

MCFCW-06-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 18,000 BTUH MCFCW-06-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 18,000 BTUH 1 Chilled and Hot Water Fan Coil High Static 4-Pipe Nominal

More information

USB VGA KVM Console Extender w/ Serial & Audio Over Cat5 UTP ft

USB VGA KVM Console Extender w/ Serial & Audio Over Cat5 UTP ft USB VGA KVM Console Extender w/ Serial & Audio Over Cat5 UTP - 1000 ft Product ID: SV565UTPUSA The SV565UTPUSA USB VGA KVM Console Extender w/ Serial & Audio Over Cat5 UTP (1000 ft) lets you control a

More information

Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2

Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2 Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2 Cisco CRS 3-Phase AC Power Distribution Unit 2 Revised: November 18, 2016,

More information

Technical Operating Information AC Unit (T150116G100) Replacement Filter No

Technical Operating Information AC Unit (T150116G100) Replacement Filter No pec-00712 Wall-Mount Cabinets ROTEK ingle-door and Double-Hinged Cabinets ROTEK ingle-door, UL and NEMA Type 4, 12 INDUTRY TANDARD UL 508A Listed; ile Number E61997 cul Listed per CA C22.2 No. 94; ile

More information

M350. Embedded Mini-ITX Enclosure. Installation Guide Version 1.0

M350. Embedded Mini-ITX Enclosure. Installation Guide Version 1.0 M350 Embedded Mini-ITX Enclosure Installation Guide Version 1.0 Before you start Please take a moment and read this manual before you start assembling this enclosure. Often times, rushing into unit installation

More information

PLC Racks IC697CHS782/783

PLC Racks IC697CHS782/783 5 1 PLC Racks IC697CHS782/783 (IC697CHS782/783) datasheet Features Accepts 3rd Party VME modules which require 0.8 spacing. Accepts all IC697 PLC module types. Rear mount rack mounts in a 10 (254 mm) deep

More information

NV1000 Terminal Equipment Operations Manual Introduction. Manual Part No. MI February, 1996

NV1000 Terminal Equipment Operations Manual Introduction. Manual Part No. MI February, 1996 Nvision@ NV1000 Terminal Equipment Operations Manual Introduction CONTENTS 1. MANUAL DESCRIPTION 2. OVERVIEW 3. POWER AND THERMAL CONSIDERATIONS 4. INSTALLATION Manual Part No. MI1000-01 February, 1996

More information

SmartPro UPS System Intelligent, line-interactive battery backup and network power management

SmartPro UPS System Intelligent, line-interactive battery backup and network power management SmartPro UPS System Intelligent, line-interactive battery backup and network power management Model #: SMART2200VS 2200VA line interactive tower UPS system Enhanced communication ports (2 USB / 2 DB9),

More information

SmartPro 208V 5kVA 3.75kW Line-Interactive Sine Wave UPS, 3U Rack/Tower, Network Card Options, USB, DB9 Serial

SmartPro 208V 5kVA 3.75kW Line-Interactive Sine Wave UPS, 3U Rack/Tower, Network Card Options, USB, DB9 Serial SmartPro 208V 5kVA 3.75kW Line-Interactive Sine Wave UPS, 3U Rack/Tower, Network Card Options, USB, DB9 Serial MODEL NUMBER: SMART5000TEL3U Highlights 5kVA / 5000VA line interactive 3U rack/tower UPS;

More information

HomeWorks Remote Power Feed-Through Panels

HomeWorks Remote Power Feed-Through Panels power feed-through panels are available in two different sizes, each of which may be either surface-mounted or recess-mounted, in an electrical closet or other equipment room. The number of remote power

More information

LVN5200A-R2, rev. 1, Hardware Installation Guide

LVN5200A-R2, rev. 1, Hardware Installation Guide LVN5200A-R2 LVN5250A-R2 LVN5200A-R2, rev. 1, Hardware Installation Guide Customer Support Information Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500) FREE technical support

More information

Cabinet. DT-NCW NETWORK CABINET WALL MOUNT 9U - 60(W)x45(D)x46(H) 71,50 +VAT

Cabinet. DT-NCW NETWORK CABINET WALL MOUNT 9U - 60(W)x45(D)x46(H) 71,50 +VAT Cabinet DT-NCW-2-6409 NETWORK CABINET WALL MOUNT 9U - 60(W)x45(D)x46(H) 71,50 +VAT SPCC cold rolled steel One section wall mount rack Fan, shelf for optional DT-NCW-2-6412 NETWORK CABINET 12U - 60(W)x45(D)x59(H)

More information

OPTICAL HEADEND PLATFORM OTOHP-CH 3RU CHASSIS OTOHP-PS POWER SUPPLY MODULE OTOHP-BP BLANK PANEL INSTRUCTION MANUAL

OPTICAL HEADEND PLATFORM OTOHP-CH 3RU CHASSIS OTOHP-PS POWER SUPPLY MODULE OTOHP-BP BLANK PANEL INSTRUCTION MANUAL OPTICAL HEADEND PLATFORM OTOHP-CH 3RU CHASSIS OTOHP-PS POWER SUPPLY MODULE OTOHP-BP BLANK PANEL INSTRUCTION MANUAL Phone: (209) 586-1022 (800) 545-1022 Fax: (209) 586-1026 OTOHP-CH Rev. X1 E-Mail: salessupport@olsontech.com

More information

SmartOnline 208/240V 3kVA 2.4kW Double-Conversion UPS, 3U Rack/Tower, Extended Run, SNMPWEBCARD Option, DB9 Serial

SmartOnline 208/240V 3kVA 2.4kW Double-Conversion UPS, 3U Rack/Tower, Extended Run, SNMPWEBCARD Option, DB9 Serial SmartOnline 208/240V 3kVA 2.4kW Double-Conversion UPS, 3U Rack/Tower, Extended Run, SNMPWEBCARD Option, DB9 Serial MODEL NUMBER: SU3000RTXL3UHV Highlights 3000VA / 3kVA / 2400 watt on-line double-conversion

More information

TAA SmartPro 208/120V 5kVA 4kW Line- Interactive Sine Wave UPS, 6U, Extended Run, Network Card Options, USB, DB9

TAA SmartPro 208/120V 5kVA 4kW Line- Interactive Sine Wave UPS, 6U, Extended Run, Network Card Options, USB, DB9 TAA SmartPro 208/120V 5kVA 4kW Line- Interactive Sine Wave UPS, 6U, Extended Run, Network Card Options, USB, DB9 MODEL NUMBER: SM5000RT3UTAA Highlights Federal Trade Agreements Act / TAA Compliant for

More information

Thunderbolt 3 to FireWire Adapter - Card & Chassis

Thunderbolt 3 to FireWire Adapter - Card & Chassis Thunderbolt 3 to FireWire Adapter - Card & Chassis Product ID: BNDTB1394B3 The Thunderbolt 3 to 1394 FireWire adapter connects your FireWire peripherals to your Thunderbolt 3 computer. This adapter combines

More information

INSTRUCTION MANUAL RA 19-7B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

INSTRUCTION MANUAL RA 19-7B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES INSTRUCTION MANUAL RA 19-7B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES KEPCO INC. An ISO 9001 Company. MODEL RA 19-7B RACK ADAPTER ORDER NO. REV. NO. IMPORTANT NOTES: 1) This manual

More information

100 - SERIES NETWORK SWITCHES QUICK START GUIDE

100 - SERIES NETWORK SWITCHES QUICK START GUIDE 100 - SERIES NETWORK SWITCHES QUICK START GUIDE Unmanaged AV Rack Network Switches FCC Warning This device has been tested and found to comply with limits for a Class A digital device, pursuant to Part

More information

Improve the appearance and accessibility of your rack

Improve the appearance and accessibility of your rack Vertical Cable Organizer with D-Ring Hooks - 0U - 6 ft. StarTech ID: CMVER40UD This 6-foot vertical cable manager (2 x 3-foot panels) gives you a simple and space-efficient way to organize the cables in

More information

SmartOnline Expandable Rack/Tower UPS System On-line, double-conversion protection for mission-critical applications

SmartOnline Expandable Rack/Tower UPS System On-line, double-conversion protection for mission-critical applications SmartOnline Expandable Rack/Tower UPS System On-line, double-conversion protection for mission-critical applications Model #: SU2200RTXL2U 2200VA on-line 2U rack / tower UPS Enhanced serial communications

More information

599 Series Zone Valve Actuator SF Series Electronic Valve Actuator, 2-position Control

599 Series Zone Valve Actuator SF Series Electronic Valve Actuator, 2-position Control 599 Series Zone Valve Actuator SF Series Electronic Valve Actuator, 2-position Control Technical Instructions EA1021R1 Description The 599 SF Series electronic zone valve actuators, accepts 24 Vac, 120

More information

Vigilant LED Floodlight - CE. for Indoor and Outdoor Industrial Applications

Vigilant LED Floodlight - CE. for Indoor and Outdoor Industrial Applications Vigilant LED Floodlight - CE for Indoor and Outdoor Industrial Applications On when it matters most. Products and solutions that protect your business 2 www.dialight.com Dialight_LED_Dual_Vigilant_Floodlight_SpecSheet_Australia_CE_120-277_VAC_Jan2018

More information

Installation and Maintenance

Installation and Maintenance CHAPTER 4 Installation and Maintenance Revised: April 19, 2010, Introduction This chapter explains how to install a SCE 1000 platform in a rack or in a general tabletop or workbench installation. Additionally,

More information

EXN4000 Storage Expansion Unit Installation and Setup Instructions

EXN4000 Storage Expansion Unit Installation and Setup Instructions IBM System Storage EXN4000 Storage Expansion Unit Installation and Setup Instructions GC27-2079-02 IBM System Storage EXN4000 Storage Expansion Unit Installation and Setup Instructions GC27-2079-02 Notices

More information

Vigilant LED Floodlight - CE. for Indoor and Outdoor Industrial Applications

Vigilant LED Floodlight - CE. for Indoor and Outdoor Industrial Applications for Indoor and Outdoor Industrial Applications On when it matters most. Products and solutions that protect your business 2 www.dialight.com Dialight_LED_Vigilant_Floodlight_SpecSheet_CE_120-277_VAC March2018

More information

NOMAD 4000 Marking System

NOMAD 4000 Marking System Nomad 4000 Marking System General Arrangement SYSTEM OVERVIEW The Telesis NOMAD 4000 marking system permanently prints messages into a variety of materials such as steel, aluminum, and plastic. A hardened

More information

Eco-Surge 8-Outlet Surge Protector, 8-ft. Cord, 2880 Joules, Tel/Modem/Coax/Ethernet Protection

Eco-Surge 8-Outlet Surge Protector, 8-ft. Cord, 2880 Joules, Tel/Modem/Coax/Ethernet Protection Eco-Surge 8-Outlet Surge Protector, 8-ft. Cord, 2880 Joules, Tel/Modem/Coax/Ethernet Protection MODEL NUMBER: AV88SATG Highlights 8 outlets / 8-ft. cord 2880 joule rating Auto/Manual switch offers GREEN

More information

Installation Job Aid for Ethernet Routing Switch 5900 Series

Installation Job Aid for Ethernet Routing Switch 5900 Series Installation Job Aid for Ethernet Routing Switch 5900 Series Notices NN47211-301 Issue 05.01 November 2017 Notice paragraphs alert you about issues that require your attention. The following paragraphs

More information

Dell SC7020 Storage Controller Getting Started Guide

Dell SC7020 Storage Controller Getting Started Guide Dell SC7020 Storage Controller Getting Started Guide Regulatory Model: E03T Regulatory Type: E03T001 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better

More information

INSTRUCTION MANUAL RA 19-4B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

INSTRUCTION MANUAL RA 19-4B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES INSTRUCTION MANUAL RA 19-4B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES KEPCO INC. An ISO 9001 Company. MODEL RA 19-4B RACK ADAPTER ORDER NO. REV. NO. IMPORTANT NOTES: 1) This manual

More information

FMPe30.48G 48VDC RECTIFIER 60 Amps 2900 Watts

FMPe30.48G 48VDC RECTIFIER 60 Amps 2900 Watts FMPe30.48G 48VDC RECTIFIER 60 Amps 2900 Watts DESCRIPTION The FMPe30.48G rectifier incorporates resonant technology to reduce component stresses, providing increased system reliability and a best-in-class

More information

INSTRUCTION MANUAL RA 19-5B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

INSTRUCTION MANUAL RA 19-5B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES INSTRUCTION MANUAL RA 19-5B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES KEPCO INC. An ISO 9001 Company. MODEL RA 19-5B RACK ADAPTER ORDER NO. REV. NO. IMPORTANT NOTES: 1) This manual

More information

SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications

SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications Model #: SU6000RT3UHV 6000VA online 6U rack / tower UPS (3U Power Module + 3U Battery

More information

ZCM-V2+T. PoE+ IP to Analog Gateway (Zone Controller) Used In the ZC1PRO+T and ZC2PRO+T

ZCM-V2+T. PoE+ IP to Analog Gateway (Zone Controller) Used In the ZC1PRO+T and ZC2PRO+T 1/5 ZCM-V2+T PoE+ IP to Analog Gateway (Zone Controller) Used In the ZC1PRO+T and ZC2PRO+T ZCM-V2+T Front ZC1PRO+T Model Includes (1) ZCM-V2+T and PA702-RMK Rack Mount Kit Features Network Features Dynamic

More information

SCv360 Expansion Enclosure

SCv360 Expansion Enclosure SCv360 Expansion Enclosure Getting Started Guide Regulatory Model: CYAE Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION:

More information

Improve the appearance and accessibility of your rack

Improve the appearance and accessibility of your rack Vertical Cable Organizer with D-Ring Hooks - 0U - 3 ft. StarTech ID: CMVER20UD This 3-foot vertical cable manager gives you a simple and space-efficient way to organize the cables in your server rack.

More information

4-Port HDMI KVM Switch - USB p

4-Port HDMI KVM Switch - USB p 4-Port HDMI KVM Switch - USB 3.0-1080p Product ID: SV431HDU3A2 This 4-Port USB 3.0 HDMI KVM switch lets you control four HDMI computers with a single monitor, keyboard and mouse. The KVM also features

More information

Technical Operating Information AC Unit (T150116G100) Replacement Filter No Wall-Mount Cabinets

Technical Operating Information AC Unit (T150116G100) Replacement Filter No Wall-Mount Cabinets 763.422.2600 pec-00712 763.422.2211 Wall-Mount Cabinets ROTEK ingle-door and Double-Hinged Cabinets Wall-Mount Cabinets ROTEK ingle-door and Double-Hinged Cabinets ROTEK ingle-door, UL and NEMA Type 4,

More information

INSTRUCTION MANUAL HIGH CURRENT DRIVER BOARD STAND ALONE

INSTRUCTION MANUAL HIGH CURRENT DRIVER BOARD STAND ALONE Instruction Manual High Current Driver Board Stand Alone 1 INSTRUCTION MANUAL HIGH CURRENT DRIVER BOARD STAND ALONE Models: 1 AMP: HCDBSA1_0AMP 1.5 AMP: HCDBSA1_5AMP 2.0 AMP: HCDBSA2_0AMP 2.5 AMP: HCDBSA2_5AMP

More information

XenaBay Chassis Installation Guide

XenaBay Chassis Installation Guide XenaBay Chassis Installation Guide HOW TO INSTALL XENA TEST MODULES Version 2.8 Xena Networks ApS Lottenborgvej 26, 2nd floor 2800 KGS Lyngby Denmark www.xenanetworks.com 1 SPECIFICATIONS The XenaBay (C4-12)

More information

SmartOnline V 1kVA 800W On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial

SmartOnline V 1kVA 800W On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial SmartOnline 100-120V 1kVA 800W On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial MODEL NUMBER: SU1000RTXL2UA Highlights 1000VA / 1kVA / 800 watt on-line double-conversion

More information

Page/Talk Industrial Desk Sets

Page/Talk Industrial Desk Sets Models PTD-1 & PTD-5 Installation & Operation P006229 Rev. B 150622 6/22/2015 10:50 AM Ph: 403.258.3100 \ email:info@guardiantelecom.com \ www.guardiantelecom.com Table of Contents Package Contents...2

More information

TRC-190 User s Manual

TRC-190 User s Manual First Edition, November 2008 www.moxa.com/product 2008 Moxa Inc. All rights reserved. Reproduction without permission is prohibited. The software described in this manual is furnished under a license agreement

More information

Installation Job Aid for Avaya Virtual Services Platform 8400

Installation Job Aid for Avaya Virtual Services Platform 8400 Installation Job Aid for Avaya Virtual Services Platform 8400 Support Release 4.2 NN47227-305 Issue 01.06 June 2015 Go to the Avaya Support website at http://support.avaya.com for the most up-to-date documentation,

More information

Installation Note for the Cisco ME 3800X and ME 3600X Switch Power Supply and Fan Modules

Installation Note for the Cisco ME 3800X and ME 3600X Switch Power Supply and Fan Modules Installation Note for the Cisco ME 3800X and ME 3600X Switch Power Supply and Fan Modules This document provides the installation and removal instructions for the AC and DC input power supply and fan modules

More information

Installation Job Aid for VSP 4450GTX-HT- PWR+

Installation Job Aid for VSP 4450GTX-HT- PWR+ Installation Job Aid for VSP 4450GTX-HT- PWR+ Notices Release 6.1.0.0 NN46251-305 Issue 02.01 November 2017 Notice paragraphs alert you about issues that require your attention. The following paragraphs

More information

Vertiv VR Rack 1.0 GENERAL

Vertiv VR Rack 1.0 GENERAL 1.1 SUMMARY Vertiv VR Rack Guide Specifications 1.0 GENERAL This specification defines the mechanical characteristics and requirements for the Vertiv VR Rack. A series of adaptive and scalable electronic

More information

This Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount.

This Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount. This Datasheet for the IC697CHS790 Rack, 9 Slots, Rear Mount. http://www.cimtecautomation.com/parts/p-14771-ic697chs790.aspx Provides the wiring diagrams and installation guidelines for this GE Series

More information

spds-480ca Power / data supply for large-scale Ethernet installations

spds-480ca Power / data supply for large-scale Ethernet installations spds-480ca Power / data supply for large-scale installations spds-480ca Power / data supply for large-scale installations spds-480ca is a power / data supply designed for large-scale LED lighting installations

More information

Improve the appearance and accessibility of your rack

Improve the appearance and accessibility of your rack Vertical Cable Organizer with Finger Ducts - 0U - 3 ft. StarTech ID: CMVER20UF This 3-foot vertical cable manager gives you a simple and space-efficient way to organize the cables in your server rack.

More information

Dell Storage Center. Getting Started Guide. SCv2000 and SCv2020 Storage System. Regulatory Model: E09J, E10J Regulatory Type: E09J001, E10J001

Dell Storage Center. Getting Started Guide. SCv2000 and SCv2020 Storage System. Regulatory Model: E09J, E10J Regulatory Type: E09J001, E10J001 Dell Storage Center SCv2000 and SCv2020 Storage System Getting Started Guide Regulatory Model: E09J, E10J Regulatory Type: E09J001, E10J001 Notes, Cautions, and Warnings NOTE: A NOTE indicates important

More information