PD ProtEX-MAX TM Explosion-Proof Process Meter. IECEx MAX

Size: px
Start display at page:

Download "PD ProtEX-MAX TM Explosion-Proof Process Meter. IECEx MAX"

Transcription

1 PD8-000 ProtEX-MAX Explosion-Proof Process Meter MAX IECEx process 0-0 ma, -0 ma, 0- V, - V, and ±0 V Inputs Input Power Options Include 8- VAC or - VDC Modern, Sleek and Practical Enclosure Display Mountable at 0, 90, 80, & 70 Degrees Explosion-Proof, IP8, NEMA X Enclosure SunBright Display Standard Dual-Scale for Level Applications Single Input Signal Input Conditioning for Flow & Round Horizontal Tanks -Point, Square Root, or Exponential Linearization Multi-Pump Alternation Control SafeTouch Through-Glass Button Programming Modbus RS-8 Serial Communications Flanges for Wall or Pipe Mounting Isolated ma Transmitter Power Supply Onboard USB and MeterView Pro Programming Software Precision Digital Corporation

2 PD8-000 ProtEX-MAX Through-Glass Button Programming Explosion-Proof Process Meter IECEx Sunlight Readable Display Mounting Flanges (Up to ½" Pipe) SafeTouch Enter or Alarm Acknowledge Button Locking Screw Large 0." Digits On Upper Display SafeTouch Menu Button Explosion-Proof Die-Cast Aluminum NEMA X Enclosure PV, Max (Peak), Min (Valley) Programmable Function Keys User Configurable Lower Display Alarm Status Indicators Two ¾" NPT Conduit Plugs SafeTouch Right Arrow SafeTouch Display or Up Arrow INTRODUCTION SafeTouch Button Programming Key Features Standard SunBright LED Display The ProtEX-MAX is equipped with four The ProtEX-MAX PD8-000 has been designed to offer the functions sensors that operate as through-glass buttons and features of the PROVU PD000 in a great looking fully FM, CSA, so that it can be programmed and operated ATEX, and IECEx approved explosion-proof product. The PD8 without removing the cover (and exposing the series is not just a /8 DIN meter mounted in an explosion-proof electronics) in a hazardous area. The SafeTouch housing; a special bezel and electronics were designed exclusively buttons are configured by default to duplicate for the ProtEX-MAX. The bezel and faceplate give the front panel a the function of the front panel mechanical very finished appearance and house the additional electronics for pushbuttons associated with the integrated meter. the PD8. The ProtEX-MAX s SunBright display features extraordinarily bright LEDs. They are perfect for indoor and outdoor applications where visibility may be impaired by smoke, fog, dust, or distance or even in direct sunlight. Precise, Accurate, and More Informative ProtEX-MAX s large 0." upper display provides a highly accurate and precise -digit view of the process measurement. Its -bit A/D is accurate to ±0.0% of calibrated span ± count. Flow in CFH Free USB Programming Software & Cable The ProtEX-MAX comes preloaded with free MeterView Pro programming software that connects and installs directly to your PC with a standard USB cable, also provided free with each instrument. This eliminates the need to insert CDs, install drivers, or download software from the internet. The software will allow you to configure, monitor, and datalog a ProtEX-MAX PD8-000 using your PC. Just simply connect the meter to your PC with the USB cable and within minutes you will be programming it. Gallons & Setpoint Free USB Cable Included Level in Feet for Easy Software Installation Pressure Indication Configurable The upper display can be programmed to indicate PV, maximum (peak), minimum (valley), alternating maximum/minimum, one of eight alarm set points, or Modbus input. The lower display can also be configured to display engineering units, set points, user defined legends, or simply turned off. PD8 Module

3 PD8-000 ProtEX-MAX Explosion-Proof Process Meter Dual-Scale Display Feature Easy to Program The ProtEX-MAX PD8-000 has a rather unique, and very flexible dual-scale capability; a second scaled display can represent the measured input in a different form (i.e. gallons & height). This is of particular value in level applications. Please see the examples shown below. Both displays are independently scaled and are based on the -0 ma input signal. Beyond level, this function has been used for pressure & force, current & power, feet & meters, GPM & CFM, and more. The user friendly dual-line display makes the ProtEX-MAX easy to set up & program. No jumpers to set for input selection. All setup & programming can be done using the SafeTouch buttons on the front of the meter face. Three levels of password protection help maintain the reliability of the programming. Input Setup Digital communications Gallons & Height Gallons & ma Display Setup Modbus RTU Serial Communications Gallons & Percent With the purchase of a serial communication adapter, ProtEX-MAX meters can communicate with any Modbus Master device using the ever-popular Modbus communications protocol that is included in every ProtEX-MAX. This greatly increases the flexibility of the meter. Modbus provides much more capability than read PV and write set points. Below are some examples of other things that can be done with ProtEX-MAX s Modbus communications. Gallons & Head PSI Advanced Linearization Capability The ProtEX-MAX includes a -point linearizer. In non-linear level applications (i.e. some pumping or lift stations), it can easily compensate for submerged equipment or plumbing that displace usable volume. A second independent 8-point linearizer is available for a second scaled display (PV) when Level function is enabled. Precision Digital s free MeterView Pro PC-based software greatly simplifies the construction of the linearization tables. The software can save this data to the meter and/or PC. Send a -character message to the lower display upon an event Convert a digital value to a -0 ma signal Remote user control (i.e. change set points, acknowledge alarms) Input a Modbus digital PV (in place of analog input) Remote override of any, or all, relays and analog outputs On-Board Digital Input The PD8-000 includes a digital input as standard. This digital input can operate with the tare, reset tare, or interlock relays feature, force relays on from a signal from a PLC or relay on other equipment, and much more. This is ideal for installations where the meter is inaccessible behind a cover, or where an additional function key is needed for customized operation. P+ P- F COM V+ ma+ Rounding Modbus PV Input Remote Message ProtEX Videos Visit our archive at /videos to watch a video on the ProtEX-MAX Family of Explosion-Proof Meters. Here, you will also find other videos on the ProtEX Series including videos on loop powered process meters, feet and inches level meters, and flow rate/totalizers. Also, see the SafeTouch through-glass button programming in action. ACK The rounding feature is used to give the user a steadier display with fluctuating signals. It causes the display to round to the nearest value according to the rounding value selected (,,, 0, 0, 0, or 00). For example, with a rounding value of 0, and a input of, the display would indicate 0. Max/Min Display Max/Min (or Peak/Valley) is standard on the ProtEX-MAX PD Either display can be configured to show either maximum or minimum excursion since last reset. The displays can also be configured to toggle between Max and Min values. Both values can be simply reset from the front panel.

4 PD8-000 ProtEX-MAX Explosion-Proof Process Meter INTEGRATED DIGITAL I/o and serial MeterView Pro Software communications Configure, monitor, and datalog a ProtEX-MAX PD8-000 from a PC using MeterView Pro Software (available via USB or for download at ). See samples below of monitor and data logging, linearization utility, setup, and relays. Monitor & Datalog RS-8 Connectors Digital I/O Connectors Linearization Utility Digital I/O Connections Four digital inputs and four digital outputs come standard with the ProtEX-MAX. External digital inputs can function similarly to the front panel function keys or digital input F. They can be configured to trigger certain events (i.e. acknowledge/reset alarms, reset max and/or min values, disable/enable all output relays, and hold current relay states), or provide a direct menu access point. The inputs can be used to configure the meter remotely using panel mount push buttons on a control station, giving the user remote control of the four front panel push buttons. Digital outputs can be used to remotely monitor the ProtEX-MAX s alarm relay output states, or the states of a variety of actions and functions executed by the meter. Setup Note: The onboard digital inputs (-) are configured at the factory to function identically to the front panel pushbuttons (Menu, F, F, & F) in order to work with the SafeTouch buttons. Changing the programming of the digital inputs will affect the function of the SafeTouch buttons. Serial Communications Connections Relays ProtEX-MAX meters come with an RS-8 connection for serial communications with other digital devices. The industry standard Modbus RTU protocol is included with every meter.

5 PD8-000 ProtEX-MAX Explosion-Proof Process Meter OUTPUTS Relay Outputs The ProtEX-MAX has up to four A Form C relays (SPDT) with multiple power loss fail-safe options. Relays can be configured for proper protective action upon input loop break. Relay ON and OFF delay times are user adjustable. Up to four front panel indicators show alarm and/or relay state. All relays can be configured for 0-00% deadband. Relay Operation/Configuration There are powerful relay functions that can be configured in the ProtEX-MAX meter, including: Automatic reset only (non-latching) Automatic + manual reset at any time (non-latching) Latching (manual reset only) Latching with clear (manual reset only after alarm condition has cleared) Pump alternation control (automatic reset only) Sampling (activated for a user-specified time) User selectable fail-safe operation Relay action for loss (break) of -0 ma input signal Time delay (on and off), independent for each relay Manual control mode Interlock relay mode Analog Output The isolated analog retransmission signal can be configured to represent the process variable (PV), maximum (peak) value, minimum (valley) value, the value for any of the eight relay set points, or Modbus input. While the output is nominally -0 ma, the signal will accurately accommodate under- and over-ranges from to ma. Interlock Relay(s) This function allows a process to use one or more very low voltage input signals or simple switch contacts to control the state of one or more internal interlock relays. A violation (i.e. loss of input, open switch, or open circuit) forces one or more N/O interlock relay contacts to open. One input can be used in series with a number of interlock switches, or up to eight inputs can be required to force-on one (or more) internal interlock relays. Please see Safety Interlock on the ProVu Series whitepaper on our website for more information. +V I Interlock Contact (Digital Input) Signal input conditioning COM Control Relay LOAD Non-linear input signals (i.e. weirs & flumes, differential pressure, etc.) can be linearized with the ProtEX-MAX s simple to use built-in signal input conditioners, such as: square-root extractor, exponential linearizer, horizontal round tank linearizer, or the ProtEX-MAX s powerful general purpose -point linearizer. COM Interlock Relay NEUT VAC Manual Output Control Take control of any output with this feature. All relays can be forced ON or OFF, and the -0 ma output signal can be set to any value within its range. When the relays and -0 ma output are controlled manually, an LED labeled M is turned on and the associated Alarm LEDs (-8) flash every 0 seconds indicating that the meter is in manual control mode. Isolated Transmitter Power Supplies A powerful ma power supply is a standard feature on the ProtEX-MAX meter. It can be configured for, 0, or V (default) by means of a simple internal jumper (see manual). An additional power supply ( ma) is standard with the -0 ma output option. Sampling Function (PV Triggered Timed Relay) The sampling function allows the operator to set a set point for a sampling relay. When the PV reaches that set point, it will close that relay s contacts for a preset period of time (0. to seconds). An example of its use may be for beer/ale fermentation. When the batch reaches a certain ph, the relay contacts would close and by some means (light, horn, etc.) alert someone to take a sample, or provide the trigger to automatically take a sample of the batch. The utility of this function can, of course, be expanded beyond sampling and be used whenever a timed relay output closure is required when the PV reaches a certain set point. Weir Flow Calculated Using Exponential Signal Input Conditioner Round Horizontal Tank Signal Input Conditioner

6 PD8-000 ProtEX-MAX Explosion-Proof Process Meter Dimensions Multi-Pump Alternation Up to 8 pumps can be alternated/sequenced. Units: Inches (mm) Connections Form C (SPDT) relays Two isolated supplies available even on / VDC input power models Removable terminal blocks or relays + isolated -0 ma output option -0 ma Output Powered by ProtEX-MAX RELAY RELAY RELAY RELAY C C C - + MA OUT C I- I+ R V SIGNAL ProteX-MAX Explosion-Proof P+ P- F COM V+ ma+ 7 8 M-LINK All the proven features of the PROVU brought into your hazardous areas! Go to /pd8 + - ProtEX-MAX provides ma to power the transmitter PD8-000 ProtEX-MAX Explosion-Proof + - POWER M-LINK connection from Integrated electronics to ProtEX-MAX connector board. Universal 8- VAC or / VDC input power Voltage or current inputs No jumpers needed for V/mA input selection M-Link for adding expansion modules Digital input (F)

7 PD8-000 ProtEX-MAX Explosion-Proof Process Meter SPECIFICATIONS Except where noted all specifications apply to operation at + C. General Display: Upper display: 0.0" ( mm) high. Lower display: 0." ( mm) high. Both are digits ( to ), red LEDs. Display Intensity: Eight intensity levels Display Update Rate: /second (00 ms) Overrange: Display flashes Underrange: Display flashes Display Assignment: The upper and lower displays may be assigned to PV, PV, PCT (percent), max/min, alternate max & min, set points, units (lower display only), or Modbus input. Programming Methods: Four SafeTouch through-glass buttons when cover is installed. Four internal pushbuttons when cover is removed. F Digital Input Contacts:. VDC on contact. Connect normally open contacts across F to COM. F Digital Input Logic Levels: Logic High: to VDC; Logic Low: 0 to. VDC Noise Filter: Programmable from to 99 (0 will disable filter) Filter Bypass: Programmable from 0. to 99.9% of calibrated span Recalibration: Calibrated at the factory. Recalibration is recommended at least every months. Max/Min Display: Max / min readings reached by the process are stored until reset by the user or until power to the meter is turned off. Password: Three programmable passwords restrict modification of programmed settings. Non-Volatile Memory: All programmed settings are stored in nonvolatile memory for a minimum of ten years if power is lost. Input Power Options: 8- VAC 0/0 Hz, 90- VDC, 0 W max, or optional model with - VDC ±0%, W max. Fuse: Required external fuse: UL Recognized, A max, slow blow; up to meters may share one A fuse. Isolated Transmitter Power Supply: Terminals P+ & P-: VDC ± 0%. Isolated from the input at >00 V. Jumper selectable for, 0, or VDC supply (internal jumper J). All models transmitter supply ma max. Normal Mode Rejection: Greater than 0 db at 0/0 Hz Isolation: kv input/output-to-power line. 00 V input-to-output or output-to-p+ supply. Overvoltage Category: Installation Overvoltage Category II: Local level with smaller transient overvoltages than Installation Overvoltage Category III. Environmental: T Class operating temperature range Ta = -0 to 0 C T Class operating temperature range Ta = -0 to C Max Power Dissipation: Maximum power dissipation limited to. W. Connections: Removable screw terminal blocks accept to AWG wire, RJ for external relays, digital I/O, and serial communication adapters. Enclosure: Explosion-proof die cast aluminum with glass window, corrosion resistant epoxy coating, color: blue. NEMA X, 7, & 9, IP8. Default conduit connections: Four ¾" NPT threaded conduit openings and two ¾" NPT metal conduit plugs with mm hex key fitting installed. Additional conduit opening configurations may be available; verify quantity and sizes on specific device labeling during installation. Mounting: Four slotted flanges for wall mounting or NPS ½" to ½" or DN 0 to mm pipe mounting. Dimensions:." x 7.97" x 8.7" (W x H x D) ( mm x 0 mm x mm) Weight:.0 lbs (7. kg) Warranty: years parts & labor USB Connection: Compatibility: USB.0 Standard, Compliant Connector Type: Micro-B receptacle Cable: USB A Male to Micro-B Cable Driver: Windows 98/SE, ME, 000, Server 00/008, XP /-Bit, Vista /-Bit, Windows 7 /-Bit, Windows 0 /-Bit Power: USB Port Process Input Inputs: Field selectable: 0-0, -0 ma, ±0 VDC (0-, -, 0-0 V), Modbus PV (Slave) Accuracy: ±0.0% of calibrated span ± count, square root & programmable exponent accuracy range: 0-00% of calibrated span Temperature Drift: 0.00% of calibrated span/ C max from 0 to C ambient, 0.0% of calibrated span/ C max from -0 to 0 C ambient Signal Input Conditioning: Linear, square root, programmable exponent, or round horizontal tank volume calculation. Multi-Point Linearization: to points for PV or PV. to 8 points for PV (Dual-Scale Level feature) Programmable Exponent:.000 to.9999 Low-Flow Cutoff: (0 disables cutoff function) Decimal Point: Up to five decimal places or none: d.ddddd, dd.dddd, ddd.ddd, dddd.dd, ddddd.d, or dddddd. Calibration Range: -0 ma: minimum span input & input : 0. ma. ±0 V: minimum span input & : 0.0 V. An Error message will appear if input and input signals are too close together. Input Impedance: Voltage ranges: greater than MΩ. Current ranges: 0-00 Ω (depending on resettable fuse impedance). Input Overload: Current input protected by resettable fuse, 0 VDC max. Fuse resets automatically after fault is removed. Relays Rating: or SPDT (Form C) internal and/or SPST (Form A) external; rated 0 VDC and /0 VAC resistive load; / HP ( 0 /0 VAC for inductive loads such as contactors, solenoids, etc. Noise Suppression: Noise suppression is recommended for each relay contact switching inductive loads. Deadband: 0-00% of span, user programmable High or Low Alarm: User may program any alarm for high or low trip point. Unused alarm LEDs and relays may be disabled (turned off). Relay Operation: automatic (non-latching), latching (requires manual acknowledge), sampling (based on time), pump alternation control ( to 8 relays), Off (disable unused relays and enable interlock feature, manual on/off control mode). Relay Reset: User selectable via front panel buttons or digital inputs.. Automatic reset only (non-latching), when input passes the reset point.. Automatic + manual reset at any time (non-latching).. Manual reset only, at any time (latching).. Manual reset only after alarm condition has cleared (latching). Note: Front panel button or digital input may be assigned to acknowledge relays programmed for manual reset. Time Delay: 0 to seconds, on & off relay time delays. Programmable and independent for each relay. Fail-Safe Operation: Programmable and independent for each relay. Note: Relay coil is energized in non-alarm condition. In case of power failure, relay will go to alarm state. Auto Initialization: When power is applied to the meter, relays will reflect the state of the input to the meter. Serial Communications Protocol: Modbus RTU Meter Address/Slave ID: - 7 Baud Rate: 00-9,00 bps Transmit Time Delay: Programmable between 0 and 99 ms or transmitter always on for RS- communication Data: 8 bit ( start bit, or stop bits) Parity: Even, odd, or none with or stop bits Byte-to-Byte Timeout: seconds Turn Around Delay: Less than ms (fixed) Note: Refer to the PROVU Register Tables located at for details. 7

8 PD8-000 ProtEX-MAX Explosion-Proof Process Meter Isolated -0 ma Transmitter Output Output Source: Process variable (PV), max, min, set points -8, manual control setting, or Modbus input Scaling Range:.000 to.000 ma for any display range Calibration: Factory calibrated:.000 to = -0 ma output Analog Output Programming:.000 ma maximum for all parameters: Overrange, underrange, max, min, and break Accuracy: ± 0.% of span ± 0.00 ma Temperature Drift: 0. μa/ C max from 0 to C ambient, 0.8 μa/ C max from -0 to 0 C ambient Note: Analog output drift is separate from input drift. Isolated Transmitter Power Supply: Terminals I+ & R: VDC ± 0%. Isolated from the input at >00 V. May be used to power the -0 ma output or other devices. All ma max. External Loop Power Supply: VDC maximum Output Loop Resistance: Power supply Minimum Maximum VDC 0 Ω 700 Ω VDC (external) 00 Ω 00 Ω Product Ratings and Approvals FM: Type X; IP Class I, Division, Groups B, C, D Class II, Division, Groups E, F, G Class III, Division, T/T Class I, Zone, AEx d, IIC Gb T/T Zone, AEx tb IIIC T90 C; Ta -0 C to + C T Ta = -0 C to +0 C; T Ta = -0 C to + C Certificate Number: 078 CSA: Class I, Division, Groups B, C, D Class II, Division, Groups E, F, G Class III, Division Class I Zone Ex d IIC Zone Ex tb IIIC T90 C -0 C < Tamb. < +0 C; Temperature Code T -0 C < Tamb. < + C; Temperature Code T Enclosure Type X & IP Certificate Number: 7 ATEX: II G D Ex d IIC T* Gb Ex tb IIIC T90 C Db IP8 Ta = -0 C to +* C *T = -0 C to +0 C *T = -0 C to + C Certificate number: Sira ATEX8 IECEx: Ex d IIC T* Gb Ex tb IIIC T90 C Db IP8 Ta = -0 C to +* C *T = -0 C to +0 C *T = -0 C to + C Certificate Number: IECEx SIR.007 ordering information 8- VAC Model ProtEX-MAX PD8-000 Models - VDC Options Installed Model PD8-000-H0 PD H0 None PD8-000-H PD H Relays PD8-000-H PD H -0 ma Output PD8-000-H PD H Relays PD8-000-H PD H Relays & -0 ma Output PD8-000-H7 PD H7 Relays & -0 ma Output Note: V Transmitter power supply standard on all models. Model PDAPLUG7 PDA78-I PDA78-N PDA88-I PDA88-N Accessories Description /" NPT Stainless Steel Stopping Plug with Approvals RS- to RS-/8 Isolated Converter RS- to RS-/8 Non-Isolated Converter USB to RS-/8 Isolated Converter USB to RS-/8 Non-Isolated Converter PDA8 Pipe Mounting Kit Zinc Plated (Requires ) PDA8-SS Pipe Mounting Kit Stainless Steel (Requires ) Disclaimer Your Local Distributor is: The information contained in this document is subject to change without notice. Precision Digital Corporation makes no representations or warranties with respect to the contents hereof, and specifically disclaims any implied warranties of merchantability or fitness for a particular purpose. 0 Precision Digital Corporation. All rights reserved. LDS8-000_A 0/ Precision Digital Corporation South Street Hopkinton MA 078 USA Tel (800) -00 Fax (08) -8990

PD ProtEX-MAX Analog Input Feet & Inches Meter. IECEx MAX

PD ProtEX-MAX Analog Input Feet & Inches Meter.   IECEx MAX PD8-6001 ProtEX-MAX Analog Input Feet & Inches Meter TM MAX IECEx Feet & Inches process Modern, Sleek and Practical Enclosure Display Mountable at 0, 90, 180, & 270 Degrees Explosion-Proof, IP68, NEMA

More information

PD ProtEX-MAX Strain Gauge, Load Cell & mv Meter. Strain gauge. IECEx MAX

PD ProtEX-MAX Strain Gauge, Load Cell & mv Meter.   Strain gauge. IECEx MAX PD8-6100 ProtEX-MAX Strain Gauge, Load Cell & mv Meter TM MAX IECEx Strain gauge Modern, Sleek and Practical Enclosure Display Mountable at 0, 90, 180, & 270 Degrees Explosion-Proof, IP68, NEMA 4X Enclosure

More information

PD ProtEX-MAX TM Dual-Input Process Meter DUAL-INPUT PROCESS. IECEx. MAX

PD ProtEX-MAX TM Dual-Input Process Meter DUAL-INPUT PROCESS. IECEx.   MAX PD8-6060 ProtEX-MAX TM Dual-Input Process Meter TM MAX IECEx DUAL-INPUT PROCESS Dual-Input Process Meter with Math Functions Addition, Difference, Average, Multiplication, Division, Min, Max, Weighted

More information

Remote Level Display with Explosion Proof Enclosure

Remote Level Display with Explosion Proof Enclosure Remote Level Display with Explosion Proof Enclosure Features Modern, Sleek and Practical Enclosure Display Mountable at 0, 90, 180, & 270 Degrees Explosion-Proof, IP68, NEMA 4X Enclosure SafeTouch Through-Glass

More information

PD Large Display Feet & Inches Process Meter. Feet & Inches process. Actual Size Digit

PD Large Display Feet & Inches Process Meter.   Feet & Inches process. Actual Size Digit PD2-6001 Large Display Feet & Inches Process Meter Actual Size Digit Feet & Inches process Feet & Inches Display Ideal for Level Applications Large 1.80ꞌꞌ Dual-Line 6-Digit Display Readable from up to

More information

PD6000. PROVU Dual-Line 6-Digit Process Meter. SERIES

PD6000. PROVU Dual-Line 6-Digit Process Meter.  SERIES PD6000 PROVU Dual-Line 6-Digit Process Meter PR VU SERIES process 0-0 ma, -0 ma, 0- V, - V, and ±0 V Inputs NEMA X, IP6 Front Input Power Options Include 8-6 VAC or - VDC Large Dual-Line 6-Digit Display,

More information

PD Large Display Dual-Line 6-Digit Process Meter. process. Actual Size Digit

PD Large Display Dual-Line 6-Digit Process Meter.   process. Actual Size Digit PD2-6000 Large Display Dual-Line 6-Digit Process Meter Actual Size Digit process Large 1.80ꞌꞌ Dual-Line 6-Digit Display Readable from up to 100 Feet Away Superluminous Sunlight Readable Display IP65 Rated

More information

PD Large Display Dual-Line 6-Digit Process Meter. process. Actual Size Digit

PD Large Display Dual-Line 6-Digit Process Meter.  process. Actual Size Digit PD2-6000 Large Display Dual-Line 6-Digit Process Meter Actual Size Digit process Large 1.80ꞌꞌ Dual-Line 6-Digit Display Readable from up to 100 Feet Away Superluminous Sunlight Readable Display NEMA X,

More information

PD Helios Dual-Line 6-Digit Temperature Meter. Actual Size Digit

PD Helios Dual-Line 6-Digit Temperature Meter.   Actual Size Digit PD2-7000 Helios Dual-Line 6-Digit Temperature Meter Actual Size Digit Temperature Large 1.80" Digits Dual-Line 6-Digit Display Readable from up to 100 Feet (30 Meters) Away Superluminous Sunlight Readable

More information

DPM-500. Dual-Line 6-Digit Process Meter FEATURES

DPM-500. Dual-Line 6-Digit Process Meter FEATURES DPM-00 USB Install FEATURES 0-0 ma, -0 ma, 0- V, - V, and ±0 V Inputs NEMA X, IP6 Front Input Power Options Include 8-6 VAC or - VDC Large Dual-Line 6-Digit Display, 0.60" & 0.6" Dual-Scale for Applications

More information

PD7000. PROVU Dual-Line 6-Digit Temperature Meter SERIES.

PD7000. PROVU Dual-Line 6-Digit Temperature Meter SERIES. PD7000 PROVU Dual-Line 6-Digit Temperature Meter PR VU SERIES Temperature J, K, T, E, R, S, B, N, C Thermocouples 00 or 000 Ω Platinum, 0 Ω Copper, 0 Ω Nickel RTDs or 0. Resolution Averages up to 0 RTD

More information

PD8-6200/PD ProtEX-MAX TM Dual-Line 6-Digit Flow Rate/Totalizers. IECEx. Precision Digital Corporation

PD8-6200/PD ProtEX-MAX TM Dual-Line 6-Digit Flow Rate/Totalizers. IECEx.   Precision Digital Corporation PD8-6200/PD8-6300 ProtEX-MAX TM Dual-Line 6-Digit Flow Rate/Totalizers TM MAX PD8-6200 Analog Input PD8-6300 Pulse Input IECEx flow rate/total Common ProtEX-MAX TM METER Features Modern, Sleek and Practical

More information

H3 Series. Nanmac Corporation. Dual-Line 6-Digit Temperature Meter.

H3 Series. Nanmac Corporation. Dual-Line 6-Digit Temperature Meter. H3 Series Dual-Line 6-Digit Temperature Meter Temperature J, K, T, E, R, S, B, N, C Thermocouples 100 or 1000 Ω Platinum, 10 Ω Copper, 120 Ω Nickel RTDs 1 or 0.1 Resolution Averages up to 10 RTD Sensors

More information

dual-line 6-dIGIt process MeteR

dual-line 6-dIGIt process MeteR dual-line 6-dIGIt process MeteR ProVu Se r i e S provu Model pd6000 0-20 ma, 4-20 ma, 0-5 V, 1-5 V, and ±10 V Inputs NEMA 4X, IP65 Front Universal 85-265 VAC or 12/24 VDC Input Power Large Dual-Line 6-Digit

More information

PD8-6080/PD6081 ProtEX-MAX TM Super Snooper Modbus Scanners

PD8-6080/PD6081 ProtEX-MAX TM Super Snooper Modbus Scanners PD8-6080/PD6081 ProtEX-MAX TM Super Snooper Modbus Scanners TM MAX USB Install IECEx MODBUS S C A N N E R S Modern, Sleek and Practical Enclosure Display Mountable at 0, 90, 180, & 270 Degrees Explosion-Proof,

More information

PD Helios Strain Gauge, Load Cell & mv Meter. Strain gauge. Actual Size Digit

PD Helios Strain Gauge, Load Cell & mv Meter.  Strain gauge. Actual Size Digit PD2-6100 Helios Strain Gauge, Load Cell & mv Meter Actual Size Digit Strain gauge Large 1.80" Digits Dual-Line 6-Digit Display Readable from up to 100 Feet (30 Meters) Away Superluminous Sunlight Readable

More information

PD765 TRIDENT. Trident Series Process & Temperature Meters.

PD765 TRIDENT. Trident Series Process & Temperature Meters. PD765 Trident Series Process & Temperature Meters TRIDENT PROCESS & Temp 4-20 ma, ± 10 V, TC & RTD Inputs 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm) Type 4X, NEMA 4X, IP65 Front 1/8 DIN Shallow

More information

PD6060. PROVU Dual-Input Process Meter SERIES.

PD6060. PROVU Dual-Input Process Meter SERIES. PD6060 PROVU Dual-Input Process Meter PR VU SERIES Dual-input PROCESS Dual-Input Process Meter with Math Functions Addition, Difference, Average, Multiplication, Division, Min, Max, Weighted Average, Ratio,

More information

PD765 TRIDENT. Trident Series Process & Temperature Meters.

PD765 TRIDENT. Trident Series Process & Temperature Meters. PD765 Trident Series Process & Temperature Meters TRIDENT PROCESS & Temp 4-20 ma, ± 10 V, TC & RTD Inputs 4-Digit Display, 0.56" (14.2 mm) or 1.20" (30.5 mm) Linear or Square Root with Low-Flow Cutoff

More information

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm) 4-20 ma & Relay Output Features 4-20 ma, ± 10 V, TC & RTD Inputs 12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm) 24 VDC @ 200 ma Transmitter Power Supply Options Type

More information

DUAL-LINE TEMPERATURE METER

DUAL-LINE TEMPERATURE METER DUAL-LINE TEMPERATURE METER PROPLUS YPP7000 J, K, T, E, R, S, B, N, C Thermocouples 100 or 1000 Ω Platinum, 10 Ω Copper, 120 Ω Nickel RTDs 1 or 0.1 Resolution Averages up to 10 RTD Sensors Automatic Cold

More information

PD8-6262/PD ProtEX-MAX TM Dual-Input Rate/Totalizers. flow rate/total. IECEx. Isolated ma Transmitter Power Supply

PD8-6262/PD ProtEX-MAX TM Dual-Input Rate/Totalizers. flow rate/total. IECEx.   Isolated ma Transmitter Power Supply PD8-6262/PD8-6363 ProtEX-MAX TM Dual-Input Rate/Totalizers TM MAX PD8-6262 Analog Input PD8-6363 Pulse Input IECEx flow rate/total Common ProtEX-MAX TM Dual-input METER Features Modern, Sleek and Practical

More information

PD6210 / PD6310. PROVU Dual-Line 6-Digit Batch Controllers BATCH CONTROL. PRECISION DIGITAL CORPORATION SERIES

PD6210 / PD6310. PROVU Dual-Line 6-Digit Batch Controllers BATCH CONTROL.  PRECISION DIGITAL CORPORATION SERIES PD6210 / PD6310 PROVU Dual-Line 6-Digit Batch Controllers PR VU SERIES BATCH CONTROL COMMON BATCH CONTROLLER FEATURES Start / Pause / Stop, Change Batch with Front Panel Buttons Display Batch Total, Rate,

More information

PD6200 / PD6300. PROVU Dual-Line 6-Digit Flow Rate/Totalizers SERIES. Precision Digital Corporation

PD6200 / PD6300. PROVU Dual-Line 6-Digit Flow Rate/Totalizers SERIES.  Precision Digital Corporation PD6200 / PD6300 PROVU Dual-Line 6-Digit Flow Rate/Totalizers PR VU SERIES flow rate/total Common PROVU METER Features NEMA 4X, IP65 Front Input Power Options Include 85-265 VAC or 12-24 VDC Dual-Line 6-Digit

More information

Trident and Trident X2 Digital Process and Temperature Panel Meter

Trident and Trident X2 Digital Process and Temperature Panel Meter Sign In New User ISO 9001:2008 Certified Quality System Home Products Online Tools Videos Downloads About Us Store Contact Policies Trident and Trident X2 Digital Process and Temperature Panel Meter Products

More information

High Voltage DC Meter

High Voltage DC Meter High Voltage DC Meter Javelin D PD644 0-300 VDC input NEMA 4X, IP65 front Scale in engineering units Sunlight readable LED display 4-20 ma analog output Two form C 3 A relays option RS-485 serial communications

More information

PD6210 / PD6310. PROVU Dual-Line 6-Digit Batch Controllers. Batch control SERIES. Precision Digital Corporation

PD6210 / PD6310. PROVU Dual-Line 6-Digit Batch Controllers. Batch control SERIES.  Precision Digital Corporation PD6210 / PD6310 PROVU Dual-Line 6-Digit Batch Controllers PR VU SERIES Batch control Common batch controller Features Start / Pause / Stop, Change Batch with Front Panel Buttons Display Batch Total, Rate,

More information

Dual-Input process meter

Dual-Input process meter Dual-Input process meter PROPLUS YPP6060 Dual-Input Process Meter with Math Functions Addition, Difference, Average, Multiplication, Division, Min, Max, Weighted Average, Ratio, Concentration, & More 0-20

More information

YPP6060. PROPLUS Dual-Line 6-Digit Process Meter. DUAL-INPUT

YPP6060. PROPLUS Dual-Line 6-Digit Process Meter.   DUAL-INPUT YPP6060 PROPLUS Dual-Line 6-Digit Process Meter DUAL-INPUT PROCESS Dual-Input Process Meter with Math Functions Addition, Difference, Average, Multiplication, Division, Min, Max, Weighted Average, Ratio,

More information

HIGH-VOLTAGE DC METER

HIGH-VOLTAGE DC METER HIGH-VOLTAGE DC METER Javelin D PD644 0-300 VDC input NEMA 4X, IP65 front Scale in engineering units Sunlight readable LED display 4-20 ma analog output Two form C 3 A relays option RS-485 serial communications

More information

PRECISION DIGITAL CORPORATION Since 1974 Dual-Line Large Display

PRECISION DIGITAL CORPORATION Since 1974 Dual-Line Large Display Helios PRECISION DIGITAL CORPORATION Since 1974 Dual-Line Large Display Readable from up to 100 Feet (30 Meters) Away Superluminous Sunlight Readable Display Large 1.80" (46 mm) Digits Six Full Digits

More information

PD6080/PD6081 PROVU Super Snooper Modbus Scanners

PD6080/PD6081 PROVU Super Snooper Modbus Scanners PD6080/PD6081 PROVU Super Snooper Modbus Scanners PR VU SERIES USB Install MODBUS S C A N N E R S Modbus RS-485 RTU Serial Communications as Master, Slave, or Snooper RS-485 Serial Communications Standard

More information

Model DDMC Digital Meter/Controller

Model DDMC Digital Meter/Controller EPMP - 1 DESCRIPTION The AMETEK powered by 85 to 265 VAC will display data from transmitters, transducers, scales, and other process instruments. It provides 24 volt excitation, alarm relays, and optional

More information

PD2-6080/PD Helios Super Snooper Modbus Scanners

PD2-6080/PD Helios Super Snooper Modbus Scanners PD2-6080/PD2-6081 Helios Super Snooper Modbus Scanners Actual Size Digit PD2-6080 MODBUS S C A N N E R S Large 1.80" Digits Dual-Line 6-Digit Display Readable from up to 100 Feet (30 Meters) Away Superluminous

More information

PD6088/PD6089 PROVU Super Snooper Modbus Scanners

PD6088/PD6089 PROVU Super Snooper Modbus Scanners PD6088/PD6089 PROVU Super Snooper Modbus Scanners PR VU SERIES USB Install MODBUS S C A N N E R S Modbus RS-485 RTU Serial Communications as Master, Slave, or Snooper RS-485 Serial Communications Standard

More information

DPM-100. Dual-Line On-Board Serial Modbus Display FEATURES

DPM-100. Dual-Line On-Board Serial Modbus Display FEATURES DPM-100 USB Install FEATURES Modbus RS-485 RTU Serial Communications as Master, Slave, or Snooper RS-485 Serial Communications Standard Scan up to 16 Modbus Process Variable Addition, Difference, Average,

More information

DPM-300. Large Display Modbus Scanner. Modbus Master, Slave, or Snooper. Features

DPM-300. Large Display Modbus Scanner. Modbus Master, Slave, or Snooper. Features Actual Size Digit Modbus Master, Slave, or Snooper Features Large 1.80" Digits Dual-Line 6-Digit Display Readable from up to 100 Feet (30 Meters) Away Superluminous Sunlight Readable Display NEMA 4X, IP65

More information

PD6060. PROVU Dual-Input Process Meter SERIES.

PD6060. PROVU Dual-Input Process Meter SERIES. PD00 PROVU PR VU SERIES Dualinput PROCESS with Math Functions Addition, Difference, Average, Multiplication, Division, Min, Max, Weighted Average, Ratio, Concentration, & More 00 ma, 0 ma, 0 V, V, and

More information

Model DDMC. Digital Meter / Controller

Model DDMC. Digital Meter / Controller Model DDMC Digital Meter / Controller Description The AMETEK Model DDMC Digital Meter/Controller powered by 85 to 265 VAC will display data from transmitters, transducers, scales, and other process instruments.

More information

PD8-6080/PD6081 ProtEX-MAX TM Super Snooper Modbus Scanners

PD8-6080/PD6081 ProtEX-MAX TM Super Snooper Modbus Scanners PD8080/PD08 ProtEXMAX TM Super Snooper Modbus Scanners TM MAX USB Install IECEx MODBUS S C A N N E R S Modern, Sleek and Practical Enclosure Display Mountable at 0, 90, 80, & 70 Degrees ExplosionProof,

More information

PD6262 / PD6363 SERIES. PROVU Dual-Input Rate/Totalizers. flow rate/total. Precision Digital Corporation

PD6262 / PD6363 SERIES. PROVU Dual-Input Rate/Totalizers. flow rate/total.   Precision Digital Corporation PD6262 / PD6363 PROVU Dual-Input Rate/Totalizers PR VU SERIES PD6262 Analog Input PD6363 Pulse Input flow rate/total Common PROVU Dual-input METER Features Rate, Total, and Grand Total for Each Input Channel

More information

Process & Temperature Digital Panel Meter

Process & Temperature Digital Panel Meter Process & Temperature Digital Panel Meter TRIDENT PD765 4-20 ma, ± 10 V, TC & RTD Inputs NEMA 4X, IP65 Front Shallow Depth Case 3.6" Behind Panel Universal Power Supply 85-265 VAC Two Relays Option with

More information

PD6262 / PD6363. PROVU Dual-Input Rate/Totalizers. flow rate/total SERIES. Precision Digital Corporation

PD6262 / PD6363. PROVU Dual-Input Rate/Totalizers. flow rate/total SERIES.   Precision Digital Corporation PD6262 / PD6363 PROVU Dual-Input Rate/Totalizers PR VU SERIES PD6262 Analog Input PD6363 Pulse Input flow rate/total Common PROVU Dual-input METER Features Rate, Total, and Grand Total for Each Input Channel

More information

MPV. Process Panel Display. Dual-Line Rate and Total

MPV. Process Panel Display. Dual-Line Rate and Total Process Panel Display Dual-Line Rate and Total measuring monitoring analyzing MPV Pulse or Analog s Displays Rate and Total Simultaneously Square Root Extraction 5, 10, or 24 V DC Flowmeter Power Supply

More information

Large DIspLay process Meters

Large DIspLay process Meters Large DIspLay process Meters Model pd650 NeMa 4X 2.3" High LeD Model pd655 NeMa 4X 1.0" High LeD Model pd656 exp-proof 4X 0.8" High LeD 4-20 ma, 1-5 V, 0-5 V, 0-10 V inputs 4½ digit + extra zero display

More information

PD6262 / PD6363. PROVU Dual-Input Rate/Totalizers. flow rate/total SERIES. Precision Digital Corporation

PD6262 / PD6363. PROVU Dual-Input Rate/Totalizers. flow rate/total SERIES.   Precision Digital Corporation PD6262 / PD6363 PROVU Dual-Input Rate/Totalizers PR VU SERIES PD6262 Analog Input PD6363 Pulse Input flow rate/total Common PROVU Dual-input METER Features Rate, Total, and Grand Total for Each Input Channel

More information

CATALOG SHORT FORM. Digital Indicators & Controllers. th ANNIVERSARY PRECISION DIGITAL CORPORATION Since 1974

CATALOG SHORT FORM. Digital Indicators & Controllers. th ANNIVERSARY PRECISION DIGITAL CORPORATION Since 1974 PRECISION DIGITAL CORPORATION Since 1974 2014 SHORT FORM th ANNIVERSARY 1974-2014 CATALOG Digital Indicators & Controllers level temperature pressure www.predig.com th ANNIVERSARY 1974-2014 PRECISION DIGITAL

More information

PDW30 Point-To-Point Wireless Bridge

PDW30 Point-To-Point Wireless Bridge PDW30 Point-To-Point Wireless Bridge WIRELESS WIreless System FEATURES Wire Replacement in a Rugged, Industrial Housing Inputs and Outputs on Both Field Units Simple to Order, Configure, & Install 1 Mile

More information

TEK- LCD 7804B. Explosion-Proof Modbus Scanner. ACCESSORIES. Technology Solutions

TEK- LCD 7804B. Explosion-Proof Modbus Scanner.   ACCESSORIES. Technology Solutions Technology Solutions TEK- LCD 7804B Explosion-Proof Modbus Scanner ACCESSORIES www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction The Tek-LCD 7804B Explosion-Proof

More information

ProtEX-MAX PD Explosion-Proof Analog Input Batch Controller Instruction Manual

ProtEX-MAX PD Explosion-Proof Analog Input Batch Controller Instruction Manual ProtEX-MAX PD8-6210 Explosion-Proof Analog Input Batch Controller Instruction Manual USB Install Batch Controller 0-20 ma, 4-20 ma, 0-5 V, 1-5 V, and ±10 V Inputs Start, Batch, Pause, & Stop with Front

More information

Short Form Catalog. Watch product videos at

Short Form Catalog.  Watch product videos at Short Form Catalog Pr cisio Digital Corporatio si c 1974 www.predig.com Watch product videos at www.predig.com/videos Short Form Catalog Table of Contents 1/8 DIN Digital Panel Meters Process Meters...4,

More information

ProtEX-MAX PD Explosion-Proof Process Meter Instruction Manual

ProtEX-MAX PD Explosion-Proof Process Meter Instruction Manual ProtEX-MAX PD8-6000 Explosion-Proof Process Meter Instruction Manual USB Install Process 0-20 ma, 4-20 ma, 0-5 V, 1-5 V, and ±10 V Inputs Multi-Pump Alternation Control Display One Input in Two Different

More information

PRECISION DIGITAL CORPORATION Since CATALOG. level temperature pressure.

PRECISION DIGITAL CORPORATION Since CATALOG. level temperature pressure. PRECISION DIGITAL CORPORATION Since 1974 level temperature pressure www.predig.com level temperature pressure INTELLIGENT MONITORING & CONTROL 2 Table of Contents 6 18 19 22 26 No Matter the Application,

More information

Introduction to The PROVU &ProtEX-MAX Great New Features!

Introduction to The PROVU &ProtEX-MAX Great New Features! PR VU SERIES TM MAX Precision Digital Presents Introduction to The PROVU &ProtEX-MAX Great New Features! Webinar Organizers Joe Ryan Sales & Marketing Manager, Product Manager Precision Digital Corporation

More information

PDW90 WIRELESS. Point To Multi-Point Wireless FEATURES BASE STATION FIELD UNITS

PDW90 WIRELESS. Point To Multi-Point Wireless FEATURES BASE STATION FIELD UNITS PDW90 Point To Multi-Point Wireless WIRELESS WIreless Sy stem FEATURES Point to Multi-Point Signal Wire Replacement Simple to Configure Using PDW Manager Programming Software and Onboard USB Range: 1 Mile

More information

ProtEX-MAX PD Explosion-Proof Pulse Input Batch Controller Instruction Manual

ProtEX-MAX PD Explosion-Proof Pulse Input Batch Controller Instruction Manual ProtEX-MAX PD8-6310 Explosion-Proof Pulse Input Batch Controller Instruction Manual USB Install Batch Controller Pulse, Open Collector, NPN, PNP, TTL, Switch Contact, Sine Wave (Coil), Square Wave Inputs

More information

Simplified information where and how you want it.

Simplified information where and how you want it. ConsolIdator 4 & 8 Multi-channel controllers Simplified information where and how you want it. ConsoliDator 4 Model PD940 ConsoliDator ConsoliDator 4 Features Four 4-20 Inputs Four 4-20 Outputs ConsoliDator

More information

Helios Large Display Analog Input Meter

Helios Large Display Analog Input Meter Helios Large Display Analog Input Meter Instruction Manual USB Install Process Large 1.80" Digits Dual-Line 6-Digit Display Readable from up to 100 Feet (30 Meters) Away Superluminous Sunlight Readable

More information

Flow Rate/Totalization Indicators

Flow Rate/Totalization Indicators Digital indicators TABLE OF CONTENTS 225 Take a closer look at Precision Digital s updated line of process indicators, alarm annunciators, scanners, and flow rate/ totalizers. PD s large display meters

More information

PD6000 Analog Input Process Meter Instruction Manual

PD6000 Analog Input Process Meter Instruction Manual PD6000 Analog Input Process Meter 0-20 ma, 4-20 ma, 0-5 V, 1-5 V, and ±10 V Inputs NEMA 4X, IP65 Front Universal 85-265 VAC or 12/24 VDC Input Power Large Dual-Line 6-Digit Display, 0.60" & 0.46" Dual-Scale

More information

PROVU PD6000 Analog Input Process Meter Instruction Manual

PROVU PD6000 Analog Input Process Meter Instruction Manual PROVU PD6000 Analog Input Process Meter Instruction Manual USB Install Process 0-20 ma, 4-20 ma, 0-5 V, 1-5 V, and ±10 V Inputs Multi-Pump Alternation Control Display One Input in Two Different Scales

More information

CATALOG. Digital Indicators & Controllers. Simplifi ed information where and how you want it. Short Form. predig.com/videos

CATALOG. Digital Indicators & Controllers. Simplifi ed information where and how you want it. Short Form. predig.com/videos Digital Indicators & Controllers predig.com/videos C US Simplifi ed information where and how you want it. FLOW LEVEL PRESSURE TEMPERATURE PRECISION DIGITAL CORPORATION Since 1974 www.predig.com TABLE

More information

PD301 - PD306 Head Mount SMART TEMPERATURE TRANSMITTERS

PD301 - PD306 Head Mount SMART TEMPERATURE TRANSMITTERS PD301 - PD306 Head Mount SMART TEMPERATURE TRANSMITTERS HART Non-HART Smart Temperature Transmitters with HART Protocol Universal Input: RTD, TC, Ohm & mv Program with PC or HART Communicator Low-Cost

More information

ProtEX-MAX PD WM Explosion-Proof NTEP Certified Batch Controller Instruction Manual

ProtEX-MAX PD WM Explosion-Proof NTEP Certified Batch Controller Instruction Manual ProtEX-MAX PD8-6310-WM Explosion-Proof NTEP Certified Batch Controller Instruction Manual USB Install Weights & Measures NTEP Certified Weighing and Measuring Device Mechanically Secured Programming Lockout

More information

ProtEX-MAX PD Explosion-Proof Pulse Input Rate/Totalizer Instruction Manual

ProtEX-MAX PD Explosion-Proof Pulse Input Rate/Totalizer Instruction Manual ProtEX-MAX PD8-6300 Explosion-Proof Pulse Input Rate/Totalizer Instruction Manual USB Install Rate/Totalizer Pulse, Open Collector, NPN, PNP, TTL, Switch Contact, Sine Wave (Coil), Square Wave Inputs 5,

More information

DIGITAL METERS Large Display Process Meter With Rate/Totalizer/Batch Control Features Model PD656 Instruction Manual

DIGITAL METERS Large Display Process Meter With Rate/Totalizer/Batch Control Features Model PD656 Instruction Manual DIGITAL METERS Large Display Process Meter With Rate/Totalizer/Batch Control Features Model PD656 Easy Single Button Scaling (SBS) 4-20 ma, 1-5 V, 0-5 V, or 0-10 V Field Selectable Inputs Large 0.8" (20.3

More information

BD300 Analog Input Process Meter Instruction Manual

BD300 Analog Input Process Meter Instruction Manual BD300 Analog Input Process Meter 0-20 ma, 4-20 ma, 0-5 V, 1-5 V, and ±10 V Inputs NEMA 4X, IP65 Front Universal 85-265 VAC, or 12/24 VDC Input Power Models Large Dual-Line 6-Digit Display, 0.60" & 0.46"

More information

Helios Large Display Temperature Meter

Helios Large Display Temperature Meter Helios Large Display Temperature Meter Instruction Manual USB Install Temperature Large 1.80" Digits Dual-Line 6-Digit Display Readable from up to 100 Feet (30 Meters) Away Superluminous Sunlight Readable

More information

ProtEX-MAX PD Explosion-Proof Strain Gauge, Load Cell & mv Meter Instruction Manual

ProtEX-MAX PD Explosion-Proof Strain Gauge, Load Cell & mv Meter Instruction Manual ProtEX-MAX PD8-6100 Explosion-Proof Strain Gauge, Load Cell & mv Meter Instruction Manual USB Install Strain Gauge 15, 30, 150, 300 mv Unipolar Input Ranges ±15, ±25, ±150, ±250 mv Bipolar Input Ranges

More information

SPECIFICATIONS SPECIFICATIONS. Input VDC. NEMA 4X/IP65 front VDC option. Temp SPECIFICATIONS

SPECIFICATIONS SPECIFICATIONS. Input VDC. NEMA 4X/IP65 front VDC option. Temp SPECIFICATIONS PD603 Sabre P Process Meter Sabre Series 0-20 ma, 4-20 ma; ±10 VDC (0-5, 1-5, 0-10 V) Display 4-digit, 0.56" (14.2 mm) Enclosure 1/8 DIN NEMA 4X/IP65 front Power 85-265 VAC or 12-36 VDC option Operating

More information

Welcome to the Webinar

Welcome to the Webinar Welcome to the Webinar Climbing Up Tanks is Dangerous and a Waste of Time Here is a Level Transmitter with a Display, but.. Precision Digital Indicators and Controllers Are the Convenient and Safe Solution

More information

PD8 Series ProtEX-MAX Supplemental Instruction Manual

PD8 Series ProtEX-MAX Supplemental Instruction Manual PD8 Series ProtEX-MAX Supplemental Instruction Manual Modern, Sleek and Practical Enclosure Display Mountable at 0, 90, 180, & 270 Degrees Explosion-Proof, IP68, NEMA 4X Enclosure PROVU, Trident X2, Snooper

More information

Viatran DL Series Analog Input Process Meter Instruction Manual

Viatran DL Series Analog Input Process Meter Instruction Manual Viatran DL Series Analog Input Process Meter Instruction Manual 199 Fire Tower Drive Tonawanda, New York USA 14150 Phone: 1.716.629.3800 Fax: 1.716.693.9162 Toll Free: 1.800.688.0030 Email: solutions@viatran.com

More information

Precision Digital Corporation 233 South Street Hopkinton MA USA Tel (800) Fax (508)

Precision Digital Corporation 233 South Street Hopkinton MA USA Tel (800) Fax (508) Helios Large Display High Voltage and Current Meter Instruction Manual USB Install High Voltage & Current Large 1.80" Digits Dual-Line 6-Digit Display Readable from up to 100 Feet (30 Meters) Away Superluminous

More information

Multi Process Meter Series MPM Instruction Manual

Multi Process Meter Series MPM Instruction Manual Series MPM Bulletin: F-MPM 0-20 ma, 4-20 ma, 0-5 V, 1-5 V, and ±10 V Inputs NEMA 4X, IP65 Front Universal 85-265 VAC or 12/24 VDC Input Power Large Dual-Line 6-Digit Display, 0.60" & 0.46" Dual-Scale for

More information

DDMC Meter / Controller

DDMC Meter / Controller DDMC Meter / Controller Analog Input Process Meter 0-20 ma, 4-20 ma, 0-5 V, 1-5 V, and ±10 V Inputs NEMA 4X, IP65 Front Universal 85-265 VAC, or 12/24 VDC Input Power Models Large Dual-Line 6-Digit Display,

More information

Helios Large Display Analog Input Rate/Totalizer

Helios Large Display Analog Input Rate/Totalizer Helios Large Display Analog Input Rate/Totalizer Instruction Manual USB Install Flow Rate/Totalizer Large 1.80" Digits Dual-Line 6-Digit Display Readable from up to 100 Feet (30 Meters) Away Superluminous

More information

PROVU Batch Controllers PD6210 Analog Input & PD6310 Pulse Input

PROVU Batch Controllers PD6210 Analog Input & PD6310 Pulse Input PROVU Batch Controllers PD6210 Analog Input & PD6310 Pulse Input PD6210: 0-20 ma, 4-20 ma, 0-5 V, 1-5 V, 10 V Inputs PD6310: Pulse, Open Collector, NPN, PNP, TTL, Switch Contact, Sine Wave (Coil), Square

More information

PROVU PD7000 Temperature Meter Instruction Manual

PROVU PD7000 Temperature Meter Instruction Manual PROVU PD7000 Temperature Meter Instruction Manual USB Install Temperature Thermocouple: J, K, T, E, R, S, B, N, C RTD: 100Ω Pt, 10Ω Cu, 120Ω Ni, 1000Ω Pt inputs 1 or 0.1 Resolution Displays up to 3300

More information

PD6000 Analog Input Process Meter Instruction Manual M387

PD6000 Analog Input Process Meter Instruction Manual M387 PD6000 Analog Input Process Meter M387 0-20 ma, 4-20 ma, 0-5 V, 1-5 V, or ±10 V Inputs Dual 6-Digit Displays, 0.60" (15 mm) & 0.46"(12 mm) Red LEDs Display Process Variable & Legend, Eng Units, or Set

More information

YPP6200 Analog Input Rate/Totalizer Instruction Manual

YPP6200 Analog Input Rate/Totalizer Instruction Manual YPP6200 Analog Input Rate/Totalizer 0-20 ma, 4-20 ma, 0-5 V, 1-5 V, ±10 V Inputs NEMA 4X, IP65 Front Universal 85-265 VAC, or 12/24 VDC Input Power Models Large Dual-Line 6-Digit Display, 0.60" & 0.46"

More information

PROVU PD6001 Analog Input Feet & Inches Meter Instruction Manual

PROVU PD6001 Analog Input Feet & Inches Meter Instruction Manual PROVU PD6001 Analog Input Feet & Inches Meter Instruction Manual USB Install PRECISION DIGITAL CORPORATION 233 South Street Hopkinton MA 01748 USA Tel (800) 343-1001 Fax (508) 655-8990 Process 0-20 ma,

More information

DIGITAL METERS Universal Analog Input Process Meter With Rate/Totalizer/Batch Control Features Instruction Manual

DIGITAL METERS Universal Analog Input Process Meter With Rate/Totalizer/Batch Control Features Instruction Manual DIGITAL METERS Universal Analog Input Process Meter With Rate/Totalizer/Batch Control Features 4-20 ma, 1-5 V, 0-5 V, or 0-10 V Field Selectable Inputs Full Six Digit Display for Total, 4½ Digit + Extra

More information

Analog Panel Meter Series APM Instruction Manual

Analog Panel Meter Series APM Instruction Manual Series APM Bulletin: L-APM 0-20 ma, 4-20 ma, 0-5 V, 1-5 V, 10 V Inputs NEMA 4X, IP65 Front Universal 85-265 VAC, or 12/24 VDC Input Power Models Large Dual-Line 6-Digit Display, 0.60" & 0.46" Dual-Scale

More information

PD6300 Pulse Input Rate/Totalizer Instruction Manual

PD6300 Pulse Input Rate/Totalizer Instruction Manual PD6300 Pulse Input Rate/Totalizer Pulse, Open Collector, NPN, PNP, TTL, Switch Contact, Sine Wave (Coil), Square Wave Inputs Gate Function for Rate Display of Slow Pulse Rates NEMA 4X, IP65 Front Universal

More information

Level-Lance Model 5400A

Level-Lance Model 5400A Sales Manual Section 100 PRODUCT SPECIFICATION 5400A GENERAL DESCRIPTION The ROBERTSHAW Level-Lance Model 5400A is a microprocessor based, multi-point On-Off capacitance type level detection system. Utilizing

More information

ProtEX-MAX PD8-765 Explosion-Proof Process & Temperature Meter Instruction Manual

ProtEX-MAX PD8-765 Explosion-Proof Process & Temperature Meter Instruction Manual ProtEX-MAX PD8-765 Explosion-Proof Process & Temperature Meter Instruction Manual Process & Temperature Accepts Current, Voltage, TC, & RTD Inputs 4 Digit Display, 0.56" (14 mm) or 1.20" (31 mm) Linear

More information

Precision Digital Corporation 233 South Street Hopkinton MA USA Tel (800) Fax (508)

Precision Digital Corporation 233 South Street Hopkinton MA USA Tel (800) Fax (508) Helios Large Display Analog Input Batch Controller Instruction Manual USB Install Large 1.80" Digits Dual-Line 6-Digit Display Readable from up to 100 Feet (30 Meters) Away Superluminous Sunlight Readable

More information

Helios Large Display Strain Gauge Meter

Helios Large Display Strain Gauge Meter Helios Large Display Strain Gauge Meter Instruction Manual USB Install Strain Gauge Large 1.80" Digits Dual-Line 6-Digit Display Readable from up to 100 Feet (30 Meters) Away Superluminous Sunlight Readable

More information

Analog Panel Meter Series APM Instruction Manual

Analog Panel Meter Series APM Instruction Manual Series APM Bulletin: L-APM 0-20 ma, 4-20 ma, 0-5 V, 1-5 V, 10 V Inputs NEMA 4X, IP65 Front Universal 85-265 VAC or 12/24 VDC Input Power Large Dual-Line 6-Digit Display, 0.60" & 0.46" Isolated 24 VDC @

More information

LAUREL. Laureate Digital Panel Meter for Process and Ratiometric Signals ELECTRONICS, INC. Features. Description

LAUREL. Laureate Digital Panel Meter for Process and Ratiometric Signals ELECTRONICS, INC. Features. Description LAUREL ELECTRONICS, INC. Laureate Digital Panel Meter for Process and Ratiometric Signals Features Reads process signals from ±200 mv to ±600V or ±2 ma to ±5A full scale Ratiometric mode for bridges and

More information

PROVU PD6060 Dual-Input Process Meter Instruction Manual

PROVU PD6060 Dual-Input Process Meter Instruction Manual PROVU PD6060 Dual-Input Process Meter Instruction Manual USB Install Dual-Input Two (2) 0-20 ma, 4-20 ma, 0-5 V, 1-5 V, and ±10 V Inputs Displays Two Process Inputs Simultaneously Math Functions Capabilities

More information

LAUREL ELECTRONICS, INC.

LAUREL ELECTRONICS, INC. LAUREL ELECTRONICS, INC. Laureate RTD Temperature Panel Meter / Controller Features Factory calibrated for 100Ω platinum, 10Ω copper & 120Ω nickel RTDs 2, 3 or 4-wire connection with lead resistance compensation

More information

Simplified information where and how you want it.

Simplified information where and how you want it. ConsolIdator 4 & 8 Multi-channel controllers Simplified information where and how you want it. ConsoliDator 4 Model PD940 ConsoliDator ConsoliDator 4 Features Four 4-20 Inputs Four 4-20 Outputs ConsoliDator

More information

Echotouch, EchoSpan & EchoSwitch Ultrasonic Liquid

Echotouch, EchoSpan & EchoSwitch Ultrasonic Liquid Echotouch, EchoSpan & EchoSwitch Ultrasonic Liquid The Echotouch, EchoSpan and EchoSwitch are innovative ultrasonic liquid level sensor families that replace float, conductance and pressure sensors that

More information

C160 Wall-/Pipe Mounted Universal Process Indicator

C160 Wall-/Pipe Mounted Universal Process Indicator Data sheet DS/ EN Rev. I Wall-/Pipe Mounted Universal Process Indicator reliable process indicator, wherever it s needed High visibility LED display the clearest view of your process status 0.1% measurement

More information

/8 DIN Universal Process Indicator

/8 DIN Universal Process Indicator Data Sheet SS/_ High visibility LED display the clearest view of your process status.% measurement accuracy precise indication of process measurement Analog and relay outputs as standard alarm and retransmission

More information

DTM Distributed Transmitter Monitor

DTM Distributed Transmitter Monitor Distributed Transmitter Monitor 96 Communication Module The 96 functions as an RS232 to RS485 convertor and / or enables (32) modules to be networked together via Modbus. Combined with the -CFG configuration

More information

Snooper Model PD865 Modbus Serial Input Instruction Manual

Snooper Model PD865 Modbus Serial Input Instruction Manual Snooper Model PD865 Modbus Serial Input Modbus RTU Master, Slave, or Snooper Mode 6-Digit Display, 0.56" (14 mm) High, Red LEDs, Sunlight Readable Linear, Square Root, or Programmable Exponent 16-Point

More information

Wall-/Pipe Mounted Universal Process Indicator

Wall-/Pipe Mounted Universal Process Indicator Data Sheet SS/_8 Wall-/Pipe Mounted Universal Process Indicator High visibility LED display the clearest view of your process status 0.1% measurement accuracy precise indication of process measurement

More information