Technical Information SMA STRING-MONITOR SSM-U-XX10 / SSM-U-XX15
|
|
- Chloe Edwards
- 6 years ago
- Views:
Transcription
1 Technical Information SMA STRING-MONITOR SSM-U-XX10 / SSM-U-XX15 SSMUXX1015-TI-en-10 Version 1.0 ENGLISH
2 1 Overview of Product Details SMA Solar Technology AG 1 Overview of Product Details Product Description The SMA String-Monitor is a PV array junction box for outdoor areas to which several strings can be connected in parallel. The SMA String-Monitor collects, measures and monitors the input currents of the strings, assists in detecting failures, thus helping to minimize power and yield losses. The measured values are transmitted from the SMA String-Monitor via Ethernet to the next SMA String-Monitor in the communication bus up to the inverter. Distances of up to 100 m between the nodes are possible when using copper cables. Greater distances of up to 2,000 m between two nodes are possible via optical fibers (see Section 8, page 24). The number of SMA String-Monitors connectable to an inverter depends on the DC inputs of the inverter. One SMA String-Monitor per DC input can be connected to the inverter. Up to ten SMA String-Monitors can be connected in line topology to each string monitoring communication terminal of the inverter (for information on the number of string monitoring communication terminals, see the inverter manual). The SMA String-Monitor is equipped with a DC load-break switch. The DC load-break switch can disconnect the PV array connected to the SMA String-Monitor from the inverter. The SMA String-Monitor may only be operated if the strings are protected with fuses. SMA Solar Technology AG guarantees the safe operation of the SMA String-Monitors in combination with inline fuse connectors as string fuses and when the inline fuse connectors are connected directly to the DC connectors of the string cables of the SMA String-Monitor. Using a different type and location of fuses for the strings does not guarantee the safe operation of the SMA String-Monitor and the observance of the thresholds by SMA Solar Technology AG. The inline fuse connectors are available as an accessory (see Section 8, page 24). There are six SMA String-Monitor models available depending on the system voltage and on the number of PV inputs to be monitored: The SSM-U-XX10 is suitable for voltages of up to 1,000 V DC and is available with XX = 16, 24 or 32 PV inputs. The SSM-U-XX15 is suitable for voltages of up to 1,500 V DC and is available with XX= 16, 24 or 32 PV inputs. Equipment and Equipment Options Depending on the product option, the SMA String-Monitor is equipped with 16, 24 or 32 measuring channels. Different numbers of string inputs and string fuses can be assigned to the measuring channels. This allows you to achieve the optimum design for your PV system and to protect the PV array from reverse currents. The interior of the SMA String-Monitor is equipped with protective covers for the lower DC input area and for the upper DC output area. This facilitates working on the disconnected lower DC input area in the SMA String- Monitor without having to disconnect the DC output area from voltage sources on the inverter side. The string fuses are attached on the outside of the enclosure of the SMA String-Monitor. This prevents additional heat in the enclosure caused by the waste heat of the string fuses. Inline fuse connectors of the SUNCLIX plug-in system by Phoenix Contact with internal gpv fuse are available as an accessory. The inline fuse connectors are connected to the pre-installed DC connectors of the string cables of the SMA String-Monitor. The inline fuse connectors can be connected to the positive and/or negative terminal of the PV inputs and are available in different electrical current strengths. The SMA String Monitor is equipped with a type II overvoltage protection. This protects the inverter against overvoltage. The SMA String-Monitor can be additionally equipped with a type II overvoltage protection for the communication connection and for the 230 V AC voltage supply of the SMA String-Monitor. 2 SSMUXX1015-TI-en-10 Technical Information
3 SMA Solar Technology AG 1 Overview of Product Details The SMA String-Monitor is equipped with a double-bit key for the switch cabinet. Profile half-cylinders are available upon request from the manufacturer of the SMA String-Monitor enclosure. DC connection: You can connect up to two DC main cables per terminal by default. You can connect DC main cables from 70 mm 2 to 400 mm 2 made of aluminum or copper to the busbar in the SMA String-Monitor by means of terminal lugs. Only tin-plated copper tube terminal lugs for copper cables or bimetal tube terminal lugs for aluminum cables are permitted. You can connect DC main cables from 70 mm 2 to 300 mm 2 made of aluminum or copper to the V-box terminals in the SMA String-Monitor. The V-box terminals are available as an accessory. For connecting the tube terminal lugs or the V-box terminals, the required material for the bolted connection is pre-mounted on the busbars. DC load-break switch: The DC load-break switch is equipped with a viewing window for the contacts. To receive feedback on the switching state of the DC load-break switch, an alarm contact is available as an accessory (see Section 8, page 24). Technical Information SSMUXX1015-TI-en-10 3
4 2 Product Description SMA Solar Technology AG 2 Product Description 2.1 Circuitry Options with Inline String Fuses The string fuses for the SMA String-Monitor are integrated as so-called "inline string fuses" on the outside of the enclosure in the string connection. The string terminals of the SMA String-Monitor are equipped with DC connectors from the SUNCLIX product range of Phoenix Contact. Suitable for the SUNCLIX plug-in system, inline fuse connectors (see Section 2.2, page 6) and Y adapters are available from SMA Solar Technology AG as accessories (see Section 8, page 24). The string terminals are located outside of the enclosure of the SMA String-Monitor. This offers several options for the circuitry and fuse protection of the strings. One-Sided Fuse Protection with Inline Fuse Connector on the Positive or Negative Terminal Figure 1: One-sided fuse protection with inline fuse connector on the positive terminal (example) Two-Sided Fuse Protection with Inline Fuse Connector on the Positive or Negative Terminal Figure 2: Two-sided fuse protection with inline fuse connector on the positive or negative terminal (example) Two Strings on One Fuse via Y Adapter Figure 3: Two strings on one fuse via Y adapter (example) 4 SSMUXX1015-TI-en-10 Technical Information
5 SMA Solar Technology AG 2 Product Description Two Fuses on One String via Y Adapter Figure 4: Two fuses on one string via Y adapter (example) Connection of Pre-Fabricated Cable Harnesses with Integrated String Fuse Figure 5: Connection of pre-fabricated cable harnesses with integrated string fuse (example) Position A B C D E F G Designation PV module DC connector (positive terminal) Inline fuse connector DC connector (negative terminal) Y adapter Integrated string fuse SMA String-Monitor Technical Information SSMUXX1015-TI-en-10 5
6 2 Product Description SMA Solar Technology AG 2.2 Inline Fuse Connector as Inline String Fuse The DC connectors and the inline fuse connectors are from the SUNCLIX plug-in system by Phoenix Contact and can be installed by easily plugging them together. For further information on this subject, see the Technical Information "IFCON Inline Fuse Connector Set16". Design of the Inline Fuse Connector by Phoenix Contact Figure 6: Design of the inline fuse connector by Phoenix Contact Position A B C D E Designation Plug-in contact (pin) from the SUNCLIX plug-in system Enclosure Electronic string fuse Connection of the plug-in contact with the fuse Plug-in contact (pin connector) from the SUNCLIX plug-in system 2.3 DC Load-Break Switch The SMA String-Monitor is equipped with a multi-terminal DC load-break switch with a viewing window for the contacts. The DC load-break switch disconnects the PV array connected to the SMA String Monitor from the inverter. Disconnection takes place at all poles. An alarm contact for the switching status of the DC load-break switch is available as an accessory (see Section 8, page 24). Upstream LV/HRC fuses required Use of the DC load-break switch is only permissible if LV/HRC fuses with gpv characteristic are installed upstream in the inverter or the main DC distribution box. 6 SSMUXX1015-TI-en-10 Technical Information
7 SMA Solar Technology AG 3 System Design 3 System Design 3.1 Design Considerations When designing an SMA String-Monitor, take the following aspects into account: Maximum current values Fuse rating Specifics for installation altitudes over 2,000 m Ambient temperatures over 50 C 3.2 Maximum Current Values The following current values must not be exceeded: Rated current (I DCmax ) up to 50 C: 315 A DC Rated current (I DCmax ) over 50 C: reduction by 2.5% per K Rated current per measurement input: 17.5 A DC The following applies: I String_max = I DC_max / number of string inputs 17.5 A The rated current applies for a maximum irradiation of 1,200 W/m 2 (hourly average value of the horizontal global radiation). In case the irradiation is higher, the rated current must be adapted linearly downwards. 3.3 Fuse Rating If you are using the inline fuse connectors offered by SMA Solar Technology AG, you can find information on the fuse rating in the Technical Information "IFCON Inline Fuse Connector Set16". If you are using other fuses, you can find information on the fuse rating in the datasheet of the fuse manufacturer. When selecting the fuse nominal values (I nom ), a reduction factor according to the manufacturer specifications for the short-circuit current of the connected PV array under standard test conditions (I SC_STC ) needs to be applied. The following applies: I SC_STC I nom x reduction factor or I nenn I SC_STC / reduction factor 3.4 Specifics for installation altitudes over 2,000 m Reduction of Maximum Fuse Current When installing at altitudes over 2,000 m, an additional reduction factor for the fuse rating needs to be taken into account (when using the inline fuse connectors offered by SMA Solar Technology AG, see the Technical Information "IFCON Inline Fuse Connector Set16"; when using other fuses, see the datasheet of the fuse manufacturer) Reduction of the Electrical Parameters of the DC Load-Break Switch The current is not being reduced. The rated voltage is reduced as follows: For installation altitudes of 2,001 m to 3,000 m = reduction by 1.0% per 100 m For installation altitudes of 3,001 m to 4,000 m = reduction by 1.2% per 100 m UV Radiation UV radiation increases by approximately 1.5% for every 100 m of altitude. For example, the UV radiation at an altitude of 4,000 m is approximately 30% stronger than at an altitude of 2,000 m. UV radiation has damaging effects on plastics. Technical Information SSMUXX1015-TI-en-10 7
8 3 System Design SMA Solar Technology AG However, the UV radiation does not impact the functionality and the insulation of the plastic enclosure of the SMA String-Monitor. Over time, merely the color and condition of the enclosure surface might change slightly. 8 SSMUXX1015-TI-en-10 Technical Information
9 SMA Solar Technology AG 4 Mounting 4 Mounting You can mount the SMA String-Monitor to a wall or to a round or square pole. The material for pole mounting is available as an accessory (see Section 8, page 24). Requirements for the mounting location: The mounting location can be outdoors or indoors. The mounting location must be shaded, e.g. under a protective roof. The mounting location must be suitable for the weight and dimensions of the SMA Sunny String Monitor. The mounting location must be suitable for the wind load. Mounting space below the SMA String Monitor when using the inline fuse connectors: at least 800 mm. Pole requirements: Permissible pole diameter for round pole respectively pole width for square pole: 160 mm to 370 mm The pole must be in a vertical position. The pole must be suitable for the weight of the SMA String Monitor. Weight of the SMA String-Monitor without accessories: 35 kg. Dimensions: Figure 7: Dimensions of the SMA String-Monitor Position A B C Explanation mm mm mm Technical Information SSMUXX1015-TI-en-10 9
10 4 Mounting SMA Solar Technology AG Position D E F Explanation mm mm mm Observe minimum clearances: Figure 8: Minimum clearances Position A B C D E Explanation 200 mm 650 mm 800 mm 150 mm 650 mm Example: mounting on the PV array structure If the PV array is mounted on a free-standing structure, the SMA String Monitor can be fixed to this structure in a shaded position. Make sure that the SMA String-Monitor enclosure is not mounted in the path of water flowing off the module surface. 10 SSMUXX1015-TI-en-10 Technical Information
11 SMA Solar Technology AG 4 Mounting Strain Relief for Cables Strain relief for the cables must be provided for mounting. Strain relief can be effected by means of an external cable support rail. The cable support rail is not included in the scope of delivery. Technical Information SSMUXX1015-TI-en-10 11
12 5 Installation SMA Solar Technology AG 5 Installation 5.1 Installing the Ethernet Cables Up to ten SMA String-Monitors can be connected to each string monitoring communication connection of the inverter in line topology (number of connections for string monitoring communication see the inverter manual). The Ethernet cables are connected to the LSA+ terminals of the electronics assembly using LSA+ punch down tools. Interference in data transmission due to unshielded power cables If unshielded power cables are used, they generate an electromagnetic field during operation which may induce interference in network cables during data transmission. When laying network cables, observe the following minimum clearances to unshielded energy cables: For installation without separating strip: at least 200 mm For installation with aluminum separating strip: at least 100 mm For installation with steel separating strip: at least 50 mm Requirements for Ethernet cables: Cable type: copper, two-conductor Number of insulated conductor pairs and insulated conductor cross-section: 4 x 2 x mm 2 to mm 2 Cable type: at least Cat5 with shielding S-UTP, F-UTP or higher Maximum cable length: 100 m The Ethernet cable must be connected in accordance with EIA/TIA 568B (8-conductor): Signal TX+ TX- RX+ Not assigned Not assigned RX- Not assigned Not assigned EIA/TIA 568B (8-conductor) Insulated conductor color White/orange Orange/white or orange White/green Blue/white or blue White/blue Green/white or green White/brown Brown/white or brown 5.2 Installing the String Cables The string cables of the PV arrays are connected to the string cables of the SMA String-Monitor via DC connectors. The string cables of the PV arrays must be equipped with DC connectors for this. The DC connectors are available as an accessory (see Section 8, page 24). The DC connectors are pre-installed on the string cables of the SMA String- Monitor. Damage to the SMA String-Monitor due to moisture penetration In order to protect the enclosure of the SMA String Monitor from moisture, all unused DC inputs must be closed with suitable protective caps on the DC connectors. The protective caps are available from Phoenix Contact. 12 SSMUXX1015-TI-en-10 Technical Information
13 SMA Solar Technology AG 5 Installation 5.3 Installing the DC Main Cables You can connect up to two DC main cables per terminal by default. The material required for the bolted connections is already pre-mounted on the busbar; further material is required depending on the type of connection and cable. Depending on the cable cross-section, the DC main cables must be connected to the busbars via terminal lugs or V-box terminals: The following options are available for connecting the DC main cables: Connecting DC Main Cables to the Busbar Using Terminal Lugs DC main cables 70 mm 2 to 400 mm 2 made of aluminum or copper Aluminum cables: additionally required material: bimetal ring terminal lugs. Copper cables: tinned copper ring terminal lugs are pre-mounted. Connecting DC Main Cables to the Busbar Using V-Box Terminals DC main cables 70 mm 2 to 300 mm 2 made of aluminum or copper Additionally required material: V-box terminals (see Section 8, page 24). Connecting the DC Main Cables with Terminal Lugs Cable requirements for connection with terminal lugs: Use copper or aluminum cables only. The cables must be designed for the maximum PV voltage. Maximum number of cables per potential: 2 Permitted cable cross-section: 70 mm 2 to 400 mm 2 Terminal lug requirements: Use tin-plated terminal lugs only. For the connection, only the supplied screws, washers and nuts must be used. The terminal lugs must be designed according to the temperature. Temperature: +95 C The width of the terminal lugs must exceed the washer diameter. Washer diameter: 32 mm. This will ensure that the defined torques are effective over the whole surface. Maximum width of the terminal lugs when connecting two cables per potential: 48 mm Connecting the DC Main Cables with V-Box Terminals The DC main cables are connected directly to the busbars with V-box terminals. The V-box terminals are available as an accessory. Cable requirements for connection with V box terminals: Use copper or aluminum cables only. The cables must be designed for the maximum PV voltage. The cables must have double or reinforced insulation. Maximum number of cables per potential: 2 Permitted cable cross-section: 70 mm 2 to 300 mm 2 Permitted conductor cross-section: Cable type Conductor cross-section per potential Round, single-strand 70 mm 2 to 150 mm 2 Round, multi-strand 70 mm 2 to 300 mm 2 Technical Information SSMUXX1015-TI-en-10 13
14 5 Installation SMA Solar Technology AG Cable type Conductor cross-section per potential Sectoral, single-strand 70 mm 2 to 240 mm 2 Sectoral, multi-strand 70 mm 2 to 240 mm 2 14 SSMUXX1015-TI-en-10 Technical Information
15 SMA Solar Technology AG 6 Network Topology 6 Network Topology Network Topology Up to ten SMA String-Monitors can be connected to each string monitoring communication connection of the inverter in line topology (number of connections for string monitoring communication see the inverter manual). Figure 9: Network topology with SMA String-Monitor (example) Position A B Designation SMA String-Monitor Inverter (example) Communication Options The SMA String-Monitor is equipped by default with Ethernet communication. Distances of up to 100 m between two nodes can be bridged via Ethernet. The SMA String-Monitor can be retrofitted with optical fiber communication, if required (see Section 8, page 24). Distances of up to 2,000 m between two nodes can be bridged via optical fiber communication. Both communication types can be combined between two SMA String-Monitors, meaning that you can use Ethernet communication and/or optical fiber communication for the communication input and for the communication output depending on the distance to be bridged. Technical Information SSMUXX1015-TI-en-10 15
16 6 Network Topology SMA Solar Technology AG Information on communication options of the inverter can be found in the inverter manual. Figure 10: Communication options (example) Position A B C D Designation SMA String-Monitor Inverter (example) Ethernet communication Optical fiber communication 16 SSMUXX1015-TI-en-10 Technical Information
17 SMA Solar Technology AG 7 Technical Data 7 Technical Data Enclosure Outdoor installation Material Combustion properties IP degree of protection in accordance with IEC IK degree of protection in accordance with IEC Protection class in accordance with IEC Shaded Glass-fiber reinforced plastic Self-extinguishing, halogen-free IP54 IK10 II Pollution degree in accordance with IEC Color RAL 7035 UV resistance in accordance with IEC Wall mounting Pole mounting* Lock cylinder Cable support rail** * available as an accessory (see Section 8, page 24) ** to be provided by the customer Yes Yes Yes Double-bit key for switch cabinet Yes Mechanical Data Enclosure width Enclosure with including vent plug Enclosure height including wall bracket lugs Enclosure height including string cable harness Enclosure depth Enclosure depth including wall bracket lugs Enclosure depth including wall bracket lugs and pole mounting bracket* Maximum weight** Weight of pole mounting bracket* Minimum clearance between enclosure and floor if inline fuse connectors are installed underneath the SMA String- Monitor 600 mm 630 mm 850 mm 1,055 mm 300 mm 320 mm 385 mm 34 kg 2.1 kg 800 mm * available as an accessory (see Section 8, page 24) ** depending on the number of string inputs of the SMA String-Monitor, without accessories Electrical Data PV array Negatively grounded/positively grounded/insulated Technical Information SSMUXX1015-TI-en-10 17
18 7 Technical Data SMA Solar Technology AG Electrical Data Rated voltage At installation altitudes over 2,000 m, an additional reduction factor must be taken into account. Rated current (I DCmax ) at 50 C* Rated current (I DCmax ) at above 50 C* Rated current per measuring input* Fuse characteristics 1,000 V DC / 1,500 V DC 2,001 m to 3,000 m reduction by 1.0% per 100 m 3,001 m to 4,000 m reduction by 1.2% per 100 m 315 A DC Reduction by 2.5% per K 17.5 A DC gpv Number of string inputs per potential 16 / 24 / 32 DC supply voltage from PV array +200 V DC to +1,500 V DC External AC supply voltage** 230 V AC ±20% DC load-break switch DC load-break switch - actuation under load DC load-break switch - actuation at 40 C Surge arrester DC Overvoltage category 400 A DC Max. 200 switching cycles Max. 100 switching cycles Type 2 (monitored) I nom = 20 ka I max = 40 ka II * Maximum continuous operating current up to the specified ambient temperature, taking a maximum irradiation up to 1,200 W/m 2 into account (hourly average value of the horizontal global radiation). In case the irradiation is higher, the rated current must be adapted linearly downwards. ** available as an accessory (see Section 8, page 24) Current Measurement Number of measuring channels 16 / 24 / 32 Current measurement range 2.5 A to A Maximum error at +25 C* ±0.5% Maximum error in temperature range* ±1.0% * based on the end value of the current measurement range Voltage Measurement Number of measuring channels 1 Voltage measurement range +250 V DC to +1,500 V DC Maximum error at +25 C* ±0.5% Maximum error in temperature range* ±1.0% * based on the current measurement range end value 18 SSMUXX1015-TI-en-10 Technical Information
19 SMA Solar Technology AG 7 Technical Data Measurement Internal Temperature SMA String-Monitor Temperature measurement range Accuracy 40 C to +100 C ±2% of measuring range end value DC Main Connection to Busbar Connection via busbar Ring terminal lugs for M12 screw Maximum conductor cross-section 400 mm 2 Suitable connection material Copper/aluminum* Number of cables per potential 1 / 2 Cable gland M50 Sealing range of cable glands** 17.0 mm to 38.5 mm * with suitable terminal lug (see Section 5.3, page 13) ** Tightness of seal must be assured using the mounted seal insert or the size-reducing seal insert supplied DC Main Connection to Box Terminals* Type of terminal V-Box terminal Maximum conductor cross-section 300 mm 2 Suitable connection material Copper/aluminum Number of cables per potential 1 / 2 Cable gland M50 Sealing range of cable gland** 17.0 mm to 38.5 mm * available as an accessory (see Section 8, page 24) ** Tightness of seal must be assured using the mounted seal insert or the size-reducing seal insert supplied Connecting the String Cable to the DC Connector* Cable type PV 1-F Conductor cross-section at 6 mm 2 DC connector 2.5 mm 2 to 6.0 mm 2 Cable diameter at 6 mm 2 DC connector 5 mm to 8 mm Conductor cross-section at 16 mm 2 DC connector 6 mm 2 to 16 mm 2 Cable diameter at 16 mm 2 DC connector * available as an accessory (see Section 8, page 24) 5.5 mm to 10.0 mm Connection Functional Grounding to DC Surge Arrester Terminal Connecting terminal plate with screw connection for grounding conductor Conductor cross-section for surge arrester type 2 25 mm 2 to 35 mm 2 Cable gland Multiple feed-through Technical Information SSMUXX1015-TI-en-10 19
20 7 Technical Data SMA Solar Technology AG Connection Functional Grounding to DC Surge Arrester Sealing range of cable gland Recommended cable type 5.0 mm to 10.2 mm NYY-O Connection Functional Grounding to Electronic Assembly Terminal Spring-cage terminal with actuation lever on the electronic assembly Conductor cross-section for surge arrester type 2 6 mm 2 Cable gland Sealing range of cable gland Recommended cable type Multiple feed-through 5.0 mm to 10.2 mm NYY-O Interfaces for Temperature Measurement Number (module/ambient temperature) 2 Plug-in temperature sensor Measurement range PT100 and PT1000 with two-, three- and four-wire measurement 40 C to +100 C Maximum error at +25 C* ±0.5% Maximum error in temperature range* ±2.0% Terminal Spring-cage terminal with actuation lever on the electronic assembly Conductor cross-section 0.08 mm 2 to 1.00 mm 2 Cable gland Sealing range of cable gland * based on the measurement range end value (with four-wire measurement) Multiple feed-through 3.2 mm to 6.5 mm Digital Input (Customer) Quantity 1 Supply voltage 24 V DC ±20% Maximum output current (for sensors) Switching threshold, low level Switching threshold high level Nominal input voltage Nominal input current Terminal 150 ma V LMAX 3 V V HMIN 15 V 24 V DC 5 ma Spring-cage terminal with actuation lever on the electronic assembly 20 SSMUXX1015-TI-en-10 Technical Information
21 SMA Solar Technology AG 7 Technical Data Digital Input (Customer) Conductor cross-section 0.08 mm 2 to 1.00 mm 2 Maximum cable length Cable gland Sealing range of cable gland 30 m Multiple feed-through 3.2 mm to 6.5 mm Digital Input for Alarm Contact* for DC Load-Break Switch Quantity 1 Design Nominal input voltage (typical) Nominal input current (typical) Terminal * available as an accessory (see Section 8, page 24) Potential-free contact 24 V DC 5 ma Supplied preassembled cable with plug contact Analog Current Input Quantity 1 Supply voltage 24 V DC ±20% Maximum output current (for sensors) Input measurement resistance Current measurement range 150 ma 250 Ω 4 ma to 20 ma Maximum error at +25 C* ±0.3% Maximum error in temperature range* ±2.0% Terminal Maximum cable length Spring-cage terminal with actuation lever on the electronic assembly 30 m Conductor cross-section 0.08 mm 2 to 1.00 mm 2 Cable gland Sealing range of cable gland * based on the measuring range end value Multiple feed-through 3.2 mm to 6.5 mm / 5.0 mm to 10.2 mm Digital Output Type Maximum switching power AC Maximum switching power DC Potential-free change-over contact 250 V AC / 2 A 24 V DC / 2 A 48 V DC / 1 A Technical Information SSMUXX1015-TI-en-10 21
22 7 Technical Data SMA Solar Technology AG Digital Output Minimum electrical endurance when the maximum switching voltage and maximum switching current are complied with Terminal 1,000,000 switching cycles Spring-cage terminal with actuation lever on the electronic assembly Conductor cross-section 0.5 mm 2 to 6.0 mm 2 Cable gland Sealing range of cable gland Multiple feed-through 3.2 mm to 6.5 mm / 5.0 mm to 10.2 mm Data Transmission Copper Wire Data interface Local area network (LAN) Connection without surge arrester Connection with surge arrester* Recommended cable type Maximum cable length Cable gland Sealing range of cable gland * available as an accessory (see Section 8, page 24) Modbus (TCP) Ethernet LSA+ RJ45 Cat5 cable with shielding S-UTP, F-UTP or higher 100 m Multiple feed-through 3.2 mm to 6.5 mm / 5.0 mm to 10.2 mm Data Transmission Optical Fiber* Data interface Local area network (LAN) Direct connection multimode optical fiber cable to optical fiber Piggy-Back** Modbus (TCP) Ethernet SC coupling Fiber type Multimode 50.0/125.0 µm or 62.5/125.0 µm Fiber grade Connection multimode optical fiber cable to splice box *** Cable gland OM1 or higher Splicing/optical fiber pigtail SC multimode Multiple feed-through Sealing range of cable gland 3.2 mm to 6.5 mm / 5.0 mm to 10.2 mm * Accessory optical fiber Piggy-Back required OF Piggy-Back accessories required (see Section 8, page 24) ** available as an accessory (see Section 8, page 24) *** available as an accessory (see Section 8, page 24); optical fiber pigtail is not included in the accessory scope of delivery Ambient Conditions Standard operating temperature range 40 C to +50 C 22 SSMUXX1015-TI-en-10 Technical Information
23 SMA Solar Technology AG 7 Technical Data Ambient Conditions Extended operating temperature range Storage temperature 40 C to +60 C 40 C to +70 C Relative humidity* 0% to 95% Maximum altitude above MSL * condensation possible 2,000 m / 4,000 m (derating) Technical Information SSMUXX1015-TI-en-10 23
24 8 Accessories SMA Solar Technology AG 8 Accessories You will find the accessories for your product in the following overview. If required, these can be ordered from SMA Solar Technology AG or your distributor. Designation Brief description SMA order number Inline fuse connector set Y connector set (available soon) Inline fuse connector set consisting of 16 PV inline fuse connectors Y connector set consisting of 16 Y connectors See the Technical Information "IFCON Inline Fuse Connector Set16" YCON16SFMM (female/2male) YCON16SMFF (male/2female) PV connector set PV connector set consisting of 16 connectors for the field wiring PVCON16S06F11 (2.5 mm 2 to 6.0 mm 2 1,100 V (+)) PVCON16S06M11 (2.5 mm 2 to 6.0 mm 2 1,100 V ( )) PVCON16S06F15 (2.5 mm 2 to 6.0 mm 2 1,500 V (+)) PVCON16S06M15 (2.5 mm 2 to 6.0 mm 2 1,500 V ( )) PVCON16S16F15 (6.0 mm 2 to 16.0 mm 2 1,500 V (+)) PVCON16S16M15 (6.0 mm 2 to 16.0 mm 2 1,500 V ( )) Optical fiber interface module for SMA String-Monitors Optical fiber splice box set for SMA String-Monitors SSM-U pole mounting set Alarm Contact Kit for SMA String- Monitors Ethernet overvoltage protection set for SMA String-Monitors Overvoltage protection set for supply voltage 230 V AC for SMA String- Monitors Optical fiber interface module with multimode SC coupling, type Piggy- Back for the SMA String-Monitor Optical fiber splice box set MM with two SC/SC Duplex patch cables as retrofit kit for the SMA String-Monitor Set for mounting the SMA String- Monitor to a pole Alarm contact set 1 NO (make contact) for the switch state indicator for the SMA String-Monitor Overvoltage protection for the Ethernet communication of the SMA String-Monitor Overvoltage protection for external 230 V AC supply voltage of the SMA String-Monitor via the inverter SSM-U-FOPB SSM-U-FOSB SSM-U-PM SSM-U-AUXCONT SSM-U-COMOVP SSM-U-AUXPBOVP 24 SSMUXX1015-TI-en-10 Technical Information
25 SMA Solar Technology AG 8 Accessories Designation Brief description SMA order number Power supply assembly for external power supply of SMA String-Monitors V box terminal set for the SMA String-Monitors SSM-U and SSMxx-21-BS Assembly for external 230 V AC supply voltage of the SMA String-Monitor via the inverter V box terminals with connection brackets SSSM-U-AUXPB AFC-300 Technical Information SSMUXX1015-TI-en-10 25
26 SMA Solar Technology
Product Details. Contents. Features and Mounting Options for SUNNY STRING-MONITOR SSM24-11
Technical Information Product Details Features and Mounting Options for SUNNY STRING-MONITOR SSM24-11 Contents The Sunny String Monitor SSM24 11 is specifically designed for monitoring large PV generators.
More informationMounting and Technical Data
Technical Information Mounting and Technical Data / ontent This document describes the technical data, the assembly and selection of cables for the D main distribution and. SM_SM--TI-en-30 Version 3.0
More informationSUNCLIX Connection technology for photovoltaics
SUNCLIX Connection technology for photovoltaics Connection technology for photovoltaics Are you looking for innovative and reliable connection technology for your PV modules, inverters or the complete
More informationAccessories for Sunny Central COMMUNICATION CABINET (COM-C)
Accessories for Sunny Central COMMUNICATION CABINET (COM-C) Technical Description COM-C-TEN084210 98-4011910 Version 1.0 EN SMA Solar Technology AG Table of Contents Table of Contents 1 Product Details...................................
More informationSelectronic accessories to support the SelectSun 3 phase grid-tie inverter range
Selectronic accessories to support the SelectSun 3 phase grid-tie inverter range Our all new SelectSun range of 3 phase solar inverters are equally at home with or without batteries. Available in 20kW
More informationBreezeMAX Wi² and BreezeACCESS Wi² Quick Installation Guide
This Quick Installation Guide is intended for experienced installers. For more information refer to the relevant sections in the BreezeMAX Wi² and BreezeACCESS Wi² System Manual. Wi² Package Content Check
More informationIF-80x Outdoor Terminal
95-10330_IF-800 V2016-10-20 Outdoor Terminal IF-80x Outdoor Terminal 1 IF-800 Outdoor / IF-801 We are pleased that you have decided to use a terminal of the IF-80x series for recording access data. Scope
More informationRMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B
3 136 Synco 700 Extension odules for heating controller RH760B RZ782B RZ783B Extension modules for use with the RH760B heating controller to provide additional auxiliary functions Use Heating plants controlled
More informationInstallation Manual Communit
Installation Manual Communit Communit-IA-A1-en-22 98-127900.02 Version 2.2 ENGLISH Legal Provisions SMA Solar Technology AG Legal Provisions The information contained in this document is the property of
More informationSUBCON-PLUS-PROFIB...
Fast connector for PROFIBUS systems Data sheet 101610_en_10 PHOENIX CONTACT 2017-03-27 1 Description The SUBCON-PLUS-PROFIB... D-SUB series is specifically designed for use in PROFIBUS systems up to 12
More informationRMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B
3 136 Synco 700 Extension odules for heating controller RH760B RZ782B RZ783B Extension modules for use with the RH760B heating controller to provide additional auxiliary functions Use Heating plants controlled
More informationTechnical data: Pin Spacing
282 Female Connectors, Double-Row Pin Spacing: 3.5 mm Universal connection for all conductor types Unique, compact, double-row connector system for conductor cross sections up to 1.5 mm 2 High-density,
More informationRhino Redundancy Module PSM24-REM360S. Operating Instructions
Rhino Redundancy Module PSM4-REM360S Operating Instructions RHINO REDUNDANCY MODULE PSM4-REM360S Description With this module and two power supplies of the PSM series (78, 90, 56, 80 and 360 watt models),
More informationOMEGA MODULAR PATCH PANEL EMPTY ENCLOSURE
OMEGA MODULAR PATCH PANEL EMPTY ENCLOSURE The Omega MPP enclosure is based on a 19" frame, with 4 empty module slots for MPP modules. Highly flexible : any mix between twisted pair and optical fiber modules.
More information4 10/100/1000T Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch. User Manual SISTP LRT
4 10/100/1000T + 2 1000 Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch User Manual V1.0 September-2013 FCC Warning This Equipment has been tested and found to comply with
More informationCabinet. DT-NCW NETWORK CABINET WALL MOUNT 9U - 60(W)x45(D)x46(H) 71,50 +VAT
Cabinet DT-NCW-2-6409 NETWORK CABINET WALL MOUNT 9U - 60(W)x45(D)x46(H) 71,50 +VAT SPCC cold rolled steel One section wall mount rack Fan, shelf for optional DT-NCW-2-6412 NETWORK CABINET 12U - 60(W)x45(D)x59(H)
More informationPart No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version
Ordering Data DATA SHEET TU520 Terminal Unit 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 214 400 R0001 1SAP 414 400 R0001 TU520-ETH, PROFINET I/O terminal unit, 24 VDC, spring
More information19" TiRAX cabinet system. from page 3. 19" NETcell cabinet system from page 31. Open 19" racks from page 43
9" TiRAX cabinet system from page 9" NETcell cabinet system from page Open 9" racks from page Wall-mounting/stand-alone distribution systems from page 5 Wall-mounting enclosure systems from page 6 Air
More informationUniversal Modules. Synco 700. Extension modules for use with controls of the Synco 700 family. Use
s 3 146 Synco 700 Universal Modules RMZ78 Extension modules for use with controls of the Synco 700 family. Use For heating, ventilation, air conditioning and chilled water plant equipped with controls
More informationSummary of shell housings and accessories Shell housing A Shell housing D EMC housing
Directory chapter 20 Page Summary of shell and accessories........................... 20.02 housing C.......................... 20.04 housing A................................................. 20.08 housing
More informationInstallation Manual SMA CLUSTER CONTROLLER
SUNNY BOY Installation Manual SMA CLUSTER CONTROLLER ENGLISH ClusterController-US-IA-en-16 Version 1.6 Legal Provisions SMA Solar Technology America LLC Legal Provisions No part of this document may be
More informationCMU 100 RS485 to 7x, 6x, 5x, 4x Multimode Fiber Optic Star Coupler User Manual
CMU 100 RS485 to 7x, 6x, 5x, 4x Multimode Fiber Optic Star Coupler User Manual CMU 100 / 2.5.6.6.6.6.6.6.6 12, CMU 100 / 8.5.6.6.6.6.6.6.6 12, CMU 100 / 2.5.6.6.6.6.6.6 12, CMU 100 / 8.5.6.6.6.6.6.6 12,
More informationCMU 100 Multimode Fiber Optic to Singlemode Fiber Optic Converter User Manual
CMU 100 Multimode Fiber Optic to Singlemode Fiber Optic Converter User Manual CMU 100 / 1.6.S - 0 CMU 100 / 7.6.S - 0 Company: Device: Document: Code: Version: Date: Ediseja 21 CMU 100 / 1.6.S - 0 User
More informationTF501, TF521 Terminal Bases
Ordering Data DATA SHEET TF501, TF521 Terminal Bases 1 Ordering Data Part No. Scope of delivery Product life cycle status 1SAP 117 000 R0271 1SAP 317 000 R0271 1SAP 117 200 R0271 1SAP 317 200 R0271 TF501-CMS,
More informationSR60 Busbar System 2/1 2/2. General Data. 2/3 Busbar routing. 2/7 Mounting components. 2/13 Accessories
/ SR0 Busbar System General Data / Busbar routing / Mounting components / Accessories / SR0 Busbar System General Data Overview The SR0 busbar system is a modular system for busbars, for installation in
More informationDescription and Assembly Instructions
Description and Assembly Instructions Modular Industrial Patch Panel Release 01 12/11 Technical Support HAC.Support@Belden.com The naming of copyrighted trademarks in this manual, even when not specially
More information9/27/04 cci Cablecom Inc. 1
cci Cablecom Inc. 1 CCI Cablecom Inc. is a privately held, women owned corporation headquartered in Aurora, CO. We manufacture a variety of voice and datacom products. Cable applications Include: Local
More informationCMU 100 RS232 to Singlemode Fiber Optic Converter User Manual
CMU 100 RS232 to Singlemode Fiber Optic Converter User Manual CMU 100 / 1.1.S - 0 CMU 100 / 7.1.S - 0 Company: Device: Document: Code: Version: Date: Ediseja 21 CMU 100 / 1.1.S - 0 User manual CMUMU11S
More informationPowerLogic High Density Metering System 1-Meter Enclosure
PowerLogic High Density Metering System 1-Meter Enclosure Installation Guide 63230-508-211A1 Safety information PowerLogic High Density Metering System 1-Meter Enclosure Important information Read these
More informationRhino Buffer Module PSM24-BFM600S. Operating Instructions
Rhino Buffer Module PSM24-BFM600S Operating Instructions RHINO BUFFER MODULE PSM24-BFM600S Description The PSM24-BFM600S Buffer Module will hold the output voltage of a 24 VDC power supply after brownouts
More information1 IF-810 or IF-811 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-810/IF-811
95-10326_V2016-10-20 IF-810/IF-811 1 IF-810 or IF-811 Terminal (Slave) Thank you for choosing an Interflex system. With an IF-810 or IF-811 terminal (slave), you have purchased a reliable device for capturing
More informationSmartLogger1000 Quick Guide. Issue: 10 Part Number: Date: HUAWEI TECHNOLOGIES CO., LTD.
SmartLogger1000 Quick Guide Issue: 10 Part Number: 31505707 Date: 2017-06-13 HUAWEI TECHNOLOGIES CO., LTD. 1. The information in this document is subject to change without notice. Every effort has been
More informationLNP-0602 series. 6-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 2*100Fx. User Manual
LNP-0602 series 6-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 2*100Fx User Manual FCC Warning This Equipment has been tested and found to comply with the limits for a Class-A
More informationHan-Brid. Contents Han-Brid Features Han-Brid Data interfaces Han-Brid Overview Han-Brid Cu
Contents Page Features... 19.02 Data interfaces... 19.03 Overview... 19.04 Cu... 19.06 F.O.... 19.08 Quintax 3 A... 19.10 RJ45 C... 19.12 USB / FireWire... 19.14 Han 4 A SC... 19.16 Hoods/Housings... 19.18
More informationTU531, TU532 Terminal Unit
Ordering Data DATA SHEET TU531, TU532 Terminal Unit 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 217 200 R0001 1SAP 217 000 R0001 1SAP 417 000 R0001 TU531, terminal unit, 230 VAC,
More informationInstallation Manual SMA SENSOR MODULE
Installation Manual SMA SENSOR MODULE ENGLISH MDSEN-US-40-IA-en-11 Version 1.1 Legal Provisions SMA Solar Technology America LLC Legal Provisions No part of this document may be reproduced, stored in a
More informationNever Beaten by Seasons
Never Beaten by Seasons Buccaneer For Data Frozen Winters! Torrential Springs! Blistering Summers! Dusty Autumns! The Buccaneer range of IP68 waterproof connectors for Ethernet, USB, Mini USB and FireWire.
More information1 IF-812 or IF-815 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-812/IF-815
95-10324_V2016-11-23 IF-812/IF-815 1 IF-812 or IF-815 Terminal (Slave) Thank you for choosing an Interflex system. With an IF-812 or IF-815 terminal (slave), you have purchased a reliable device for capturing
More informationPHOENIX CONTACT - 11/2007. This data sheet is only valid in association with the IB IL SYS PRO UM E user manual.
INTERBUS Inline Bus Coupler; Remote Bus Connections Via D-SUB Connectors REMOTE IN BA UL RD RC DSUB LD AUTOMATIONWORX Data Sheet 6362_en_03 PHOENIX CONTACT - 11/2007 REMOTE OUT Description The bus coupler
More information3M ID 3000 System. ID 3128 block. Disconnection module. ID 3100 block Wire guide housing
3M ID 3000 System ID 3128 block Disconnection module ID 3100 block Wire guide housing 71 Disconnection element 72 The ID 3000 connection system is the latest generation of insulation displacement connector
More informationXPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name
Product data sheet Characteristics XPSMF3542 Preventa safety PLC compact - Profibus DP protocol Main Range of product Product or component type Safety module name Safety module application Nov 13, 2018
More informationRugged MediaConverter
Rugged MediaConverter Installation Guide RuggedCom Inc. 30 Whitmore Road, Woodbridge, Ontario Canada L4L 7Z4 Web: http://www.ruggedcom.com/ Tel: (905) 856-5288 Fax: (905) 856-1995 Toll Free: (888) 264-0006
More informationPHOENIX CONTACT Pin. SUBCON-PLUS M ARCNET, MULTI/MININET (B&R), SYSTEM 2003 (B&R), P-NET SUCONET K1, K2 (EATON/Moeller),
Fast connector with screw terminal block connection for fieldbus systems Data sheet 00287_en_02 PHOENIX CONTACT 207-04-2 Description The SUBCON-PLUS/... D-SUB series is specifically designed for use in
More informationFL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B
Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections Data sheet 3379_en_B 1 Description PHOENIX CONTACT 2015-07-14 2 Features Media converters provide
More informationM12 connector D-coding M12 connector X-coding RJ45 IP20 connector PushPull RJ45 IP65 / IP67 connector
M12 connectors Directory Chapter Page General information....02 M12 connector D-coding....06 M12 connector X-coding....20 RJ45 IP20 connector....27 PushPull RJ45 IP65 / IP67 connector....46 Han 3 A RJ45
More information1/2 Introduction. SIMBOX LC 1/7 Introduction 1/8 Flush-mounting and surfacemounting. 1/9 Dimensional drawings
Siemens AG 200 ALPHA SIMBOX Small Distribution Boards /2 Introduction /2 Introduction /3 Flush-mounting and hollow-wall distribution boards /4 Hood-type distribution boards /5 Accessories /6 Dimensional
More informationHuawei Solar Product Training HUAWEI TECHNOLOGIES CO., LTD.
Huawei Solar Product Training HUAWEI TECHNOLOGIES CO., LTD. Contents Overview of the Product Range Huawei Solar Inverter Technical Information Huawei Smartlogger Technical Information NetECO Portal Brief
More informationSNAP Compact Fiber Optic Patch Panel
SNAP Compact Fiber Optic Patch Panel Compact size perfect for limited space enclosures UL Listed 1863 Versatile surface or DIN-Rail mount capability Slide-hinged faceplate aids field termination Patch
More informationJUMO mtron T Measuring, Control, and Automation System
sales@jumo.co.uk info.us@jumo.net Data Sheet 705040 Page 1/8 JUMO mtron T Measuring, Control, and Automation System Router module Brief description The router module is used to achieve decentralization
More informationSwitches 6/1. 6/4 Introduction. 6/5 5TE8 control switches. 6/7 5TE4 8 pushbuttons. 6/9 5TE8 On/Off switches. 6/11 5TE1 switch disconnectors
6/4 Introduction 6/5 5TE8 control switches 6/7 5TE4 8 pushbuttons 6/9 5TE8 On/Off switches 4 6/11 5TE1 switch disconnectors 6 6/1 Switch to manual? Wherever electrical systems need to be switched on or
More informationSITOP in the SIMATIC Design
Siemens AG 2017 /2 Introduction /3 1-phase, 24 V DC (for S7-300 and ET 200M) /9 1-phase, 24 V DC (for S7-1200) /11 1-phase, 24 V DC (for S7-1500 and ET 200MP) /14 3-phase, 24 V DC (ET 200pro) Siemens KT
More informationCM597 Ethernet Communication Module
Ordering Data DATA SHEET CM597 Ethernet Communication Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 173 700 R0001 1SAP 373 700 R0001 CM597-ETH, communication module Ethernet
More informationSafegard V4 Panel. Installation Datasheet. Safegard V4 Panel Installation Instructions and Datasheet release 1.7 August 2016
Safegard V4 Panel Installation Datasheet ELECTROSTATIC SENSITIVE DEVICE This product forms part of a life safety system. Failure to correctly store, handle, install and maintain the product will directly
More informationOperating Manual MULTICLUSTER BOX 12
Operating Manual MULTICLUSTER BOX 12 MC-BOX-12-3-20-BE-en-10 Version 1.0 ENGLISH Legal Provisions Legal Provisions The information contained in this document is the property of. Publishing its content,
More informationMC 11 EB-2 Power supply cabinet with external bus, AC version
MC 11 EB-2 Power supply cabinet with external bus, AC version USER/MAINTENANCE MANUAL 1 SLOT 0 SLOT 1 SLOT 2 SLOT 3 SLOT 4 SLOT 5 SLOT 6 SLOT 7 SLOT 8 SLOT 9 SLOT 10 SLOT 11 EB-2 (a) MC11 (b) (c) Figures
More informationRCMB20/RCMB Series
4 T M /-500 Series Integratable Ground Fault Monitoring Modules For Integration Into Frequency Converters and Combiner Boxes Technical Bulletin NAE1042510 / 10.2012 BENDER Inc. 700 Fox Chase, Coatesville
More informationField-terminated RJ45 connector with housing. Color housing: gray (RAL 7042). Color termination block: red.
FM45 Connector Cat. 6 A IP20, 4P, TIA 568-A/B, 10x R815651 966704105 10 Stk. 090.7437 / ähnliche Abbildung Instruction manual Field-terminated connector with housing. Color housing: gray (RAL 7042). Color
More informationPHOENIX CONTACT - 06/2007. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.
Primary switched power supply, 3-phase, output current: 40 A INTERFACE Data Sheet 102782_01_en PHOENIX CONTACT - 06/2007 Description TRIO POWER is the rail mountable 24 V power supply unit with basic functions.
More informationREDUNDANCY MODULE TSP-REM360 AND TSP-REM600
REDUNDANCY MODULE TSP-REM360 AND TSP-REM600 Operating Instructions Seite 1 Dimensions drawings: TSP-REM360 Weight: 0.882lb Gewicht: 0.40kg Seite 2 Dimensions drawings: TSP-REM600 Bottom view Top view Side
More informationWaterproof Electrical Junction Box Kits Technical Data Sheet
Description Environmentally rated electrical junction box kits, that contain all necessary accessories to complete a straightforward neat wiring installation. Plastic enclosures are equipped with flexible
More informationIssued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog
Issued February 2011 DATA SHEET 5SX2 MCB Based on Siemens Industrial Control Catalog General Data Trip characteristics Tripping characteristics acc. to EN 60 898 Tripping characteristic A, -5 Type A characteristic
More informationCONEC Industrial Ethernet Circular Sealed RJ45 Connector System consists of a RJ45 Plug Kit, a Receptacle Kit and a Protective Cover Assembly.
Revised Sept-28-2009 Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System Instructions CONEC Industrial Ethernet Circular Sealed RJ45 Connector System consists of a RJ45 Plug Kit, a Kit
More informationMechanically Activated Device for Dry Run Protection in Applications with LORENTZ Solar Pump Systems
Well Probe Mechanically Activated Device for Dry Run Protection in Applications with LORENTZ Solar Pump Systems The switch can be used to detect the water level within a well. When the water level in the
More information5/2 Product overview. 5/3 Distribution board components. 5/9 Built-in components. 5/17 Mounting components 5. Siemens ET B1 10/2009
Siemens AG 9 BETA Protecting SR Busbar Systems /2 Product overview /3 Distribution board components /9 Built-in components /17 Mounting components Siemens ET B1 10/9 BETA Protecting SR Busbar Systems Siemens
More informationPSR-SCP- 24DC/SSM/2X1 PSR-SPP- 24DC/SSM/2X1
PSR-SCP- DC/SSM/2X1 PSR-SPP- DC/SSM/2X1 Safety Relay With Downtime Monitoring INTERFACE Data Sheet PHOENIX CONTACT - 05/2006 Description The PSR-...- DC/SSM/2X1 safety relay can be used in safety circuits
More information1 10/100TX FX w/ 1 PoE Injector Industrial Switch. User Manual
1 10/100TX + 1 100FX w/ 1 PoE Injector Industrial Switch User Manual CE Mark Warning This is a Class-A product. In a domestic environment this product may cause radio interference in which case the user
More informationFL MC 2000E (SM40) LC
IEC 61850 fiber optic converter with LC fiber optic connection (1310 nm) to convert 100Base-Tx to single- or multi-mode fiber glass Data sheet 3205_en_C 1 Description PHOENIX CONTACT 2014-04-04 2 Features
More informationPerle IDS-108F(XT) Unmanaged 10/100 Ethernet Switches. Installation Guide. P/N (Rev G)
Perle IDS-108F(XT) Unmanaged 10/100 Ethernet Switches Installation Guide P/N 5500339-10 (Rev G) Overview This document contains instructions necessary for the installation and operation of the Perle IDS-108F
More informationElectrical Interconnections. Supplementary Catalog to Full Line Catalogs, Volumes 1/2/5 Edition 2012/2 1/2/5
Electrical Interconnections Supplementary Catalog to Full Line Catalogs, Volumes /2/ Edition 202/2 /2/ The new items in this catalog supplement products found in the following main catalogs /2/ Volume
More informationSIMOCODE 3UF Motor Management and Control Devices
Technical specifications General data applicable to the basic units, current measuring modules, current/voltage measuring modules, expansion modules, decoupling module and operator panel Permissible ambient
More informationIndustrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide
Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports Basic Model: KSD-541 PoE Model: KSD-541-P Installation Guide DOC.080104-1- (C) 2008 KTI Networks Inc. All rights reserved.
More informationPSR-SCP- 24DC/URM4/4X1/2X2/B PSR-SPP- 24DC/URM4/4X1/2X2/B
Safety Relay as a Contact Extension Block INTERFACE Data Sheet PHOENIX CONTACT - 05/2006 Description The PSR-...- 24DC/URM4/4X1/2X2/B safety relay can be used as a contact extension block in safety circuits
More informationZBRN1 access point- 2 RJ V AC/DC-4 displays-5 LEDs-Eth-Modbus-wireless radio
Characteristics access point- 2 RJ45-24..240V AC/DC-4 displays-5 LEDs-Eth-Modbus-wireless radio Main Range of product Product or component type Device short name Product specific application Function of
More informationENERGY SAFELY SWITCHED SWITCHGEAR. BUSBAR SYSTEM 60 mm
ENERGY SAFELY SWITCHED SWITCHGEAR BUSBAR SYSTEM 60 mm SWITCHGEAR ENERGY safely switched About Grupa Apator Who we are? Grupa Apator is a dynamic Polish capital group, it currently includes 14 companies
More informationTM3TI4 module TM3-4 inputs temperature
Characteristics module TM3-4 inputs temperature Main Range of product Product or component type Range compatibility Analogue input number 4 Analogue input type Complementary Analogue input resolution Permissible
More informationIndustrial 5-Port Fast Ethernet Switches. with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541. PoE Model: KSD-541-HP. Installation Guide
Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports Basic Model: KSD-541 PoE Model: KSD-541-HP Installation Guide DOC.141201-1- (C) 2014 KTI Networks Inc. All rights reserved.
More informationJUMO Quantum PID100/PID200/PID300
Data sheet 702020 Page 1/12 JUMO Quantum PID100/PID200/PID300 Universal PID Controller Series Brief description The Quantum series is available in the three DIN formats 48 mm x 48 mm, 48 mm x 96 mm, and
More informationTM3AI4 module TM3-4 analog inputs
Characteristics module TM3-4 analog inputs Main Range of product Product or component type Range compatibility Analogue input number 4 Analogue input type Complementary Analogue input resolution Permissible
More informationSECTION SWITCHBOARDS
SECTION 26 24 13 PART 1 - GENERAL 1.1 SUMMARY A. Work Included: 1. Switchboards 2. Commercial Metering Switchboards 3. Non-Utility Power Meters (Microprocessor-Based Metering Equipment) PART 2 - PRODUCTS
More informationHardened Media Converter
Quick Start Guide This quick start guide describes how to install and use the hardened media converter. This is the media converter of choice for harsh environments constrained by space. Physical Description
More informationAX522 Analog Input/Output Module
Ordering Data DATA SHEET AX522 Analog Input/Output Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 250 000 R0001 1SAP 450 000 R0001 AX522, analog input/output module, 8 AI
More informationOperating manual SUNNY TRIPOWER CORE1
Operating manual SUNNY TRIPOWER CORE1 SUNNY TRIPOWER ENGLISH STP50-40-BE-en-12 Version 1.2 Legal Provisions SMA Solar Technology AG Legal Provisions The information contained in these documents is property
More informationHCS Newsletter No. 43, Dated Thursday, 04 December, 2003 HCS DataLine Cabinets and Enclosures
HCS - Made in Turkey With Pride! HCS Newsletter No. 43, Dated Thursday, 04 December, 2003 HCS DataLine Cabinets and Enclosures HCS, the only Turkish manufacturer of state-of-the-art LAN cabling systems
More informationUSB Raven Port USB 3.1, 100m CAT 6a/7 Point-to-Point Extender System User Guide
USB 3-2-1 Raven 3104 4-Port USB 3.1, 100m CAT 6a/7 Point-to-Point Extender System User Guide Thank you for purchasing the USB 3-2-1 Raven 3104. Please read this guide thoroughly. This document applies
More informationDESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications
3 834 DESIO RX Individual room controllers for fan-coil systems, chilled ceilings and radiators, with MARK-compatible bus communications RXC20.1 RXC21.1 The RXC20.1 and RXC21.1 controllers are used for
More informationDI561 Digital Input Module
Ordering Data DATA SHEET DI561 Digital Input Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1TNE 968 902 R2101 1TNE 968 901 R3101 1TNE 968 901 R3103 1TNE 968 901 R3105 DI561, digital
More informationHypercable injecteur HPOE - Industrial IEEE 802.3at Gigabit PoE Injector. User Manual. v.1.0 Jun Mail :
Industrial IEEE 802.3at Gigabit PoE Injector User Manual v.1.0 Jun-2011 FCC Warning This Equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15
More informationControlesta RCO-Compact
Commissioning NOTICE The details contained in these documents and data can be changed without prior advance notice No part of these documents may be reproduced or passed on without the specific written
More informationsonnen Installation Practical
sonnen Installation Practical sonnen Components sonnenbatterie eco 8.0 Single Phase System Components 4 sonnenbatterie eco 8.0 Single Phase System Components 5 sonnenbatterie eco 8.0 Single Phase System
More informationFE8171V. 3MP 360 Panoramic View Vandal-proof
FE8171V 3MP 360 Panoramic View Vandal-proof Warning Before Installation English Power off the Network Camera as soon as smoke or unusual odors are detected. Refer to your user's manual for the operating
More informationJUMO TYA 201 Single-Phase SCR Power Controller For controlling resistive/inductive loads
Data sheet 709061 Page 1/21 JUMO TYA 201 Single-Phase SCR Power Controller For controlling resistive/inductive loads The JUMO TYA 201 represents a consistent further development of the JUMO power controller
More informationWINSTA. Full Line Catalog 2008/2009
WINSTA Full Line Catalog 2008/2009 5 Contents FULL LINE CATALOG W4, Volume 1 Rail-Mounted Terminal Block Systems FULL LINE CATALOG W4 Rail-Mounted Terminal Blocks Volume 1 X-COM -SYSTEM Terminal Strips
More informationAI531 Analog Input Module
Ordering Data DATA SHEET AI531 Analog Input Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 250 600 R0001 AI531, analog input module, 8 AI, U/I/Pt100, TC, 15 bits + sign, 4-wires
More informationOperating manual POWER PLANT CONTROLLER
Operating manual POWER PLANT CONTROLLER POWER PLANT CONTROLLER ENGLISH PPC-A1-BE-en-20 98-113900.03 Version 2.0 Legal Provisions SMA Solar Technology AG Legal Provisions The information contained in these
More informationEE360. High-End Moisture in Oil Transmitter. Typical applications. Features EE360 EE360. (+34)
is dedicated for reliable monitoring of lubrication, hydraulic and insulation oils as well as diesel fuel. In addition to highly accurate measurement of water activity (a w ) and temperature (T), calculates
More informationPHOENIX CONTACT - 10/2009
Factory Line Switches With Standard Functions AUTOMATIONWORX Data Sheet PHOENIX CONTACT - 10/2009 Description The range of Factory Line switches with standard functions in numerous versions can be used
More informationOperating instructions. Switching amplifier DN0210 DN / / 2015
Operating instructions Switching amplifier DN0210 DN0220 UK 80011079 / 00 01 / 2015 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5
More informationXPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output
Product datasheet Characteristics XPSMF4000 Preventa safety PLC compact - Safe Ethernet Main Range of product Product or component type Safety module name Safety module application Preventa Safety automation
More informationFL SWITCH SFN 5TX. Extract from the online catalog. Order No.:
Extract from the online catalog FL SWITCH SFN 5TX Order No.: 2891152 Ethernet switch, 5 TP RJ45 ports, automatic detection of data transmission rate of 10 or 100 mbps (RJ45), autocrossing function Commercial
More informationTM221CE40T controller M IO transistor PNP Ethernet
Product data sheet Characteristics TM221CE40T controller M221 40 IO transistor PNP Ethernet Complementary Main Discrete I/O number 40 Number of I/O expansion module Supply voltage limits Inrush current
More information