1 Tornado F-5 Motor Backspin Detect Relay And Probe For F-5 Motor Controller

2 Tornado F-5 Motor Backspin Detection Relay And Probe Revision 8.1 Change Log: Rev 8.1 Apr GPS updates 2

3 Table of Contents C H A P T E R 1 Specifications 4 C H A P T E R 2 Safety Overview 6 C H A P T E R 3 Introduction 7 C H A P T E R 4 Installation and Wiring 8 C H A P T E R 5 Backspin Detection Setup 10 C H A P T E R 6 Stand Alone Backspin Setup 11 A P P E N D I X Appendix A 13 3

4 Chapter 1 Specification Relay Unit Size: (w x h x d) 5.125" x 5.25"(4.25") x 2.00" (Height excluding base plate) Weight: 1.6 pounds NEMA Rating: NEMA 1 Power: Derives power through the communication link, or externally powered by 120VAC for stand-alone operation. Auxiliary output contacts, NO and NC High Voltage (HV) Probe input connection for interface to HV Probe. Communications: Two connectors for using RS/485 protocols (RJ45 type connectors). This is connected to any of the RJ45 type connectors on the unit system modules. RX and TX LEDs for indicating transmit and receive on the communication link. Blue LED for an indication that the motor is currently spinning. 4

5 High Voltage Probe Unit Size: (w x h x d) 8.75"(7.75") x 4.625" x 2.375" (Width excluding base plate) Weight: 3.7 pounds NEMA Rating: NEMA 1 Low Voltage Connection: One Phoenix connector for interface to the Backspin Relay. High Voltage connection: Three high voltage wires for connection to the motor T-leads, up to 5kVAC. 5

6 Chapter 2 Safety Warnings Overview Read and follow all Warnings, Precautions, Notes, and Instructions included in this document. A Warning identifies an immediate hazard that exists that poses some probability of causing death or serious injury. A Caution identifies potential conditions and actions that have the possibility of death or severe injury. A Note identifies the need for general safety practices which, if violated, could cause injury to personnel or damage to equipment. High voltages are exposed during operation. Do not touch exposed surfaces during test. Caution Verify wiring connections prior to applying power to the system. Damage to the equipment could result from incorrect connections. Note Inspect system ground and bonds prior to power application. Shock hazard could exist if proper ground is not maintained. Motor Control Unit The High Voltage Probe unit is connected directly to the high voltage output of the main contactor, which can be up to 5000 Volts. These High Voltages may be present during operation and set-up, and should be considered hazardous. 6

7 Chapter 3 Introduction The Backspin Relay and HV Probe is an optional part of the Motor Controller system. The backspin equipment is generally used in electric submersible pump applications in the oilfield or water well applications where detection of the backward spin of the pump is desired. When the motor is shutdown or turned off, the existing fluid in the production tubing causes the pump/motor to turn backwards as the fluid is falling back into the well. If the motor is started while this backspin is happening, this could cause damage to the equipment. The Backspin Relay can detect this backspin and prevent the manual or automatic starting of the pump until the back spinning has stopped. 120VAC Line 120VAC Neutral Relay N/O Relay Common Relay N/C A Phase Sensing B Phase Sensing C Phase Sensing Backspin Probe Connection Only Tornado F-5 Backspin Relay Module Backspin Alarm Active TX RX DRAWN BY: Global Production Solutions GPS SIZE: DATE: DWG NO REV N/A April TORNADO F-5 CONNECTION DIAGRAM N/A PROJECT: TORNADO F-5 OPERATOR MANUAL SCALE: N/A Backspin Unit Connections SHEET 1 OF 1 7

8 Chapter 4 Installation and Wiring The HV Probe unit is connected directly to the high voltage output of the main contactor, which can be up to 5000 Volts. These High Voltages may be present during operation and set-up, and should be considered hazardous. High Voltage Probe The High voltage probe has two sets of connections. The high voltage connection consists of three high voltage wires that are connected directly to the output of the 3-phase voltage of the contactor or motor leads. This HV connection is rated up to 5000 volts AC. A small cable fitted with a connector is used to connect the probe to the backspin relay unit. Mounting holes on the probe allow the probe to be mounted to the inside of the switchboard panel. Backspin Relay The backspin relay is connected to the Motor Controller system via the provided patch cord with the RJ-45 type connectors. All parts of the controller units are tied together in a daisy chain fashion using these patch cords. Each module on the controller units are equipped with two receptacles for the RJ-45 connectors to allow this to be done easily. This provides communication to the controller in order for the controller to prevent starting when backspin is in motion. A connector on the backspin relay marked Backspin Probe Connection Only is where the matching connector is plugged in from the HV probe. A third connector on the backspin relay is used for external connection and/or stand-alone operation of the backspin detection. For stand alone operation, the 120VAC power, neutral, and ground pins must be connected to an external power source. External devices for detection of the backspin can use the relay common, relay NC, and relay NO pins. When the motor is turning, the contacts will switch. This is not a standard configuration. There is one each of RX and TX LEDs for indicating transmit and receive status on the communication link. One blue LED lights to indicate motor spin, which will blink at the frequency of the motor spin whether it is running or in backspin. 8

9 Main Power ( Volts AC) 50 / 60 Hz Input L 1 L 2 L 3 Fuse 1 Fuse 2 Fuse 3 ISOLATION SWITCH Fuse 4 Fuse 5 H1 Primary Voltage PT X2 X1 120 V AC Fuse 7 Fuse 1 : App Specific Fuse 2 : App Specific Fuse 3 : App Specific Fuse 4 : 2E 4.8 kv (39551) Fuse 5 : 2E 4.8 kv (39551) Fuse 6 : 2E 4.8 kv (39551) Fuse 7 : 6 Amp 500 Volts AC Fuse 8 : 2 Amp 600 Volts AC Fuse List ***NOTE Plug in an RJ45 cable from the Motor Controller into the Display and plug in another RJ45 cable from the Motor Controller to the Backspin Relay for power. RX TX Tornado F-5 Backspin Relay Module Backspin Probe Connection Only C Phase Sensing B Phase Sensing A Phase Sensing 120VAC Neutral Relay N/O Relay Common Relay N/C H1 X2 Sensing Voltage PT Fuse 6 Fuse 8 X1 120 V AC (1) 120 VAC INPUT (2) VAC NEUTRAL (3) CT - A (4) CT - COMMON (5) CT - B (6) RELAY COMMON (7) CT - C (8) DI - 2 (9) RED LIGHT CONTACTOR (11) 120 VAC (12) START INPUT (13) DI 1 (14) SENSING VOLTS (15) AUTO INPUT (16) 120 VAC (17) MANUAL INPUT (18) ANALOG INPUT #1 (19) G (10) AMBER LIGHT ANALOG INPUT #2 (20) CT-A G CT-B G CT-C COMM 2 TX COMM 1B COMM 1A TX Tornado F-5 RX RX ESP MOTOR Backspin Alarm Active 120VAC Line Recording Ammeter MOTOR CONTACTOR BACKSPIN PROBE DRAWN BY: Global Production Solutions GPS SIZE: DATE: DWG NO: REV: N/A 24 April 2012 TORNADO F-5 CONNECTION DIAGRAM N/A PROJECT: TORNADO F-5 OPERATOR MANUAL SCALE: N/A Typical Backspin Connection SHEET 1 of 1 Figure1. Typical Connection of the Backspin Probe

10 Chapter 5 Backspin Detection Setup The backspin detection is setup using the motor controller display parameters. Under the Fault Activations Menu, the Backspin Enable parameter is set to yes if backspin detection is desired. Once the backspin has been detected, after a motor stop command or shutdown fault, the Motor Controller Display will show direction CBA/ABC and RPM in HZ this is held in the controller memory until updated approx every 2 sec, or until the backspin relay detects that the motor has stopped turning and lockout is cleared. This means if communication between motor controller and backspin relay is lost it will not reset the backspin speed or direction and you will be unable to clear lockout without changing the backspin Fault Activation Menu Enable to NO.

11 Chapter 6 Stand Alone Backspin Setup The backspin relay system can be used to prevent starting pumps while spinning, using the 120VAC input, the backspin relay output, and a motor controllers Digital or aux input and an N/C contact on the contactor. The Backspin relay output changes state only while backspin is present the N/O becomes closed and the N/C becomes open. Using the N/O and common contacts and going thru the N/C contacts on the contactor into the digital/aux input to the motor controller, this will allow the unit to start and run if the digital input/aux is set to N/C to shut down. Once the contactor is pulled the backspin alarm becomes active but the signal will not go thru the N/C contacts of the contactor until a shut down occurs, then the backspin alarm will remain closed until the spin stops. 11

12 Main Power ( Volts AC) 50 / 60 Hz Input L 1 L 2 L 3 Fuse 1 Fuse 2 Fuse 3 MOTOR CONTACTOR ISOLATION SWITCH ***NOTE VSD pulls K-1 in when unit is stopped connecting Backspin Relay to stop on customer interface board. When Backspin stops VSD will be allowed to start. This will drop K-1 and opens Backspin Relay output until VSD stops again. COMMON VSD RUN COMMAND N/O N/O N/C K-1 RELAY K-1 RELAY CONTACTS Fuse 120 VAC BACKSPIN PROBE RX TX Backspin Relay Module Tornado F-5 Backspin Alarm Active Backspin Probe Connection Only C Phase Sensing B Phase Sensing A Phase Sensing Relay N/C Relay Common Relay N/O 120VAC Neutral 120VAC Line Fuse 120 VAC VSD STOP COMMAND ESP MOTOR DRAWN BY: Global Production Solutions GPS SIZE: DATE: DWG NO: REV: N/A 24 April 2012 TORNADO F-5 CONNECTION DIAGRAM N/A PROJECT: TORNADO F-5 OPERATOR MANUAL SCALE: N/A Stand Alone Backspin Connection SHEET 1 of 1 Figure 2. Typical Connection: Stand-Alone Backspin Probe Option

13 Appendix A Product Warranty Warranty coverage: Global Production Solutions ( GPS ) warrants GPS manufactured products ( Product ) to be free of workmanship and material defects for a period of eighteen (18) months from the date of shipment to Buyer or twelve (12) months from the date of installation. GPS, at its option, will at no charge either repair, replace, or refund the purchase price of the Product during the warranty period, provided it is returned in accordance with the terms of this warranty to Hardesty Road, Oklahoma USA 74801, at GPS option, may include the replacement of parts or boards with functionally equivalent reconditioned or new parts or boards. Replaced parts or boards are warranted for the balance of the original applicable warranty period. All replaced parts, boards or Product shall become the property of GPS. Shipping costs are to be borne by the purchasing party. This express warranty is extended by GPS to the party purchasing the Product ( Buyer ) and is not assignable or transferable to any other party. This is the complete warranty for the Products, except as modified by separate agreement between GPS and Buyer. GPS is not responsible under this warranty for ancillary equipment, whether or not manufactured by GPS, which is attached to or used in connection with the Product, nor for operation of the Product with any such with any such ancillary equipment. Because each Product system is unique, GPS disclaims liability for range, coverage, or operation of the system as a whole under this warranty. This warranty applies within the fifty (50) United States and the District of Columbia. WHAT THIS WARRANTY DOES NOT COVER: Defects or damage resulting from use of the Product in other than its normal and customary manner, (b) Defects or damage from misuse, accident or neglect, (c) Defects or damage from improper testing, operation, maintenance, installation, alteration, modification or adjustment, (d) Product disassembled or repaired in such a manner as to adversely affect performance or prevent adequate inspection and testing to verify any warranty claim, (e) Product which has had the serial number removed or made illegible.

14 GENERAL PROVISIONS: This warranty sets forth the full extent of GPS responsibilities and liability regarding the Product, and repair, replacement, or refund of the purchase price, at GPS option, is Buyer s exclusive remedy. THIS WARRANTY IS GIVEN IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, WHICH ARE SPECIFICALLY EXCLUDED INCLUDING, WITHOUT LIMITATION, IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE IN NO EVENT SHALL GPS BE LIABLE FOR DAMAGES IN EXCESS OF THE PURCHASE PRICE OF THE PRODUCT, FOR ANY LOSS OF USE, LOSS OF TIME, INCONVENIENCE, COMMERCIAL LOSS, LOST PROFITS OR SAVINGS OR OTHER INCIDENTAL, SPECIAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OR INABILITY TO USE SUCH PRODUCT. PATENT AND SOFTWARE PROVISIONS: GPS will defend at its own expense any suit brought against Buyer to the extent that it is based on a claim that the Product or parts infringes a United States patent, and GPS will pay those costs and damages finally awarded against Buyer in any such suit which are attributable to any such claim, but such defense and payments are conditioned on the following: (i) that GPS will be notified promptly in writing by Buyer of any notice of such claim; and (ii) that GPS will have sole control of the defense of such suit and all negotiations for its settlement or compromise; and (iii) should the Product or parts become, or in GPS opinion be likely to become, the subject of a claim infringement of a United States patent, that Buyer will permit GPS, at its option and expense, either to procure for Buyer the right to continue using the Product or parts or to replace or modify the same so that it becomes non-infringing or to grant Buyer a credit for the Product or parts as depreciated and accept its return. The depreciation will be an equal amount per year over the lifetime of the Product or parts as established by GPS. GPS will have no liability with respect to any claim of patent infringement, which is based upon the combination of the Product or parts furnished by GPS, nor will GPS have any liability for the use of ancillary equipment or software not furnished by GPS, which is attached to or used in connection with the Product. The foregoing states the entire liability of GPS with respect to infringement of patents by the Product or any parts thereof. Laws in the United States and other countries preserve for GPS certain exclusive rights for copyrighted GPS software such as the exclusive rights to reproduce in copies and distribute copies of such GPS software. GPS software may be copied into, used in and redistributed with only the Products associated with such GPS software. No other use, including without limitation disassembly, of such GPS software or exercise of exclusive rights in such GPS software is permitted. No license is granted by implication, estoppel or otherwise under the patent rights of GPS or any third party. 14

User Guide. Control Box. RoscoLED TM.

User Guide. Control Box. RoscoLED TM. RoscoLED TM Control Box User Guide This guide applies to the following RoscoLED Control Box models: RoscoLED Control Box 300W/Static White (293 22250 0000) RoscoLED Control Box 400W/VariWhite (293 22260

More information

FTC-200 X-ray Tube Controller Users Manual

FTC-200 X-ray Tube Controller Users Manual Tubes FTC-200 X-ray Tube Controller TUB-MAN-2101 Rev. A 09/09/2009TTUB Table of Contents List of Tables...3 List of Figures...3 Introduction...3 Manual Set...3 About this Manual...4 X-Ray Safety Information...4

More information

PMDX-105. I/O Option Riser Board User s Manual. Document Revision: 1.1 Date: 7 September 2004 PCB Revision: PCB-443A

PMDX-105. I/O Option Riser Board User s Manual. Document Revision: 1.1 Date: 7 September 2004 PCB Revision: PCB-443A PMDX-105 I/O Option Riser Board User s Manual Date: 7 September 2004 PMDX Web: http://www.pmdx.com 7432 Alban Station Blvd., A105 Phone: +1 (703) 912-4991 Springfield, VA 22150-2321 USA FAX: +1 (703) 912-5849

More information

Installation and Operation Guide for PD5200 and PD5300 Automatic Transfer Switch

Installation and Operation Guide for PD5200 and PD5300 Automatic Transfer Switch Installation and Operation Guide for PD5200 and PD5300 Automatic Transfer Switch PD52 PD52S & PD52DCS PD53-100 te: The PD52S & PD52DCS are provided with LED lights. The GREEN LIGHTS indicate Shore Power

More information

R & D SPECIALTIES SERIES 100 RO CONTROLLER USERS MANUAL. 2004, by R & D Specialties, Inc. All Rights Reserved.

R & D SPECIALTIES SERIES 100 RO CONTROLLER USERS MANUAL. 2004, by R & D Specialties, Inc. All Rights Reserved. R & D SPECIALTIES 2004, by R & D Specialties, Inc. All Rights Reserved. No part of this document may be copied or reproduced in any form or by any means without the prior written permission of R & D Specialties.

More information

Sonic Ruptor 400. User Manual

Sonic Ruptor 400. User Manual Sonic Ruptor 400 User Manual Data herein has been verified and validated. It is believed adequate for the intended use of the instrument. If the instrument or procedures are used for purposes over and

More information

FNet Repeater Installation & Operator s Instruction Manual

FNet Repeater Installation & Operator s Instruction Manual FNet Repeater Installation & Operator s Instruction Manual October 2004 CTB Inc. Warranty FNet Repeater CTB Inc. Warranty CTB Inc. warrants each new Chore-Tronics product manufactured by it to be free

More information

DCM Digital Control Modules

DCM Digital Control Modules DCM Digital Control Modules TECHNICAL MANUAL Version 1.2 November 2011 Safety Precautions Caution Read Instructions: Read and understand all safety and operating instructions before using the equipment.

More information

DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies

DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies M51A Option: Isolated Analog Programming Manual Power Supplies Elgar Electronics Corporation 9250 Brown Deer Road San Diego, CA 92121-2294 1-800-73ELGAR

More information

Contents. HP E1586A Rack Mount Terminal Panel User s Manual

Contents. HP E1586A Rack Mount Terminal Panel User s Manual Contents HP E1586A Rack Mount Terminal Panel User s Manual Description... 5 Connecting to VXIbus Instruments... 5 Interconnect Cables... 5 Terminal Block Connections... 6 Using the Terminal Panel for Reference

More information

Agilent Technologies E5339A 38-Pin Low-Voltage Probe

Agilent Technologies E5339A 38-Pin Low-Voltage Probe Agilent Technologies E5339A 38-Pin Low-Voltage Probe Installation Note The 38-pin low-voltage probe provides a convenient way to connect two Agilent Technologies logic analyzer probe cables to a small

More information

Debitek Card Revalue Station Installation Manual

Debitek Card Revalue Station Installation Manual Page 1 of 5 Debitek Card Revalue Station Installation Manual General Description The Debitek Card Revalue Station family includes the Cash to Card, Cash to Card with Dispenser, Automatic Debit Machine,

More information

SATA II HDD Canister KISS DA 435 Quick Reference Guide

SATA II HDD Canister KISS DA 435 Quick Reference Guide SATA II HDD Canister KISS DA 435 Quick Reference Guide If it s embedded, it s Kontron 1. Table of Contents SATA II HDD Canister KISS DA 435 1. Table of Contents 1. Table of Contents... 1 2. Important Information...

More information

WARRANTY & LIMITATION OF LIABILITY

WARRANTY & LIMITATION OF LIABILITY MUX-485 WARRANTY & LIMITATION OF LIABILITY 1. ROTEM warrants that the product shall be free of defects in materials or workmanship and will conform to the technical specification for a period of 1 (one)

More information

Pressurized Line Leak Controller Module. For Veeder-Root TLS-350/350R Systems

Pressurized Line Leak Controller Module. For Veeder-Root TLS-350/350R Systems Installation Manual Pressurized Line Leak Controller Module For Veeder-Root TLS-350/350R Systems Manual Number 576013-499, Revision C Notice Veeder-Root makes no warranty of any kind with regard to this

More information

Resolver to Digital Expansion Board

Resolver to Digital Expansion Board Resolver to Digital Expansion Board Catalog No. EXB009A01 Installation and Operating Manual 6/98 MN1313 Table of Contents Section 1 General Information............................. 1-1 Introduction....................................

More information

LINE VOLTAGE TESTER CT101 USER S MANUAL. Please read this manual carefully and thoroughly before using this product.

LINE VOLTAGE TESTER CT101 USER S MANUAL. Please read this manual carefully and thoroughly before using this product. LINE VOLTAGE TESTER USER S MANUAL CT101 Please read this manual carefully and thoroughly before using this product. KEY FEATURES Visual indication of AC or DC voltage Easy to use approved Safe for CAT

More information

ICM 400. Three Phase Voltage Monitor with Reset Switch. Low cost line voltage protection for 3-phase motor systems

ICM 400. Three Phase Voltage Monitor with Reset Switch. Low cost line voltage protection for 3-phase motor systems ICM 400 Three Phase Voltage Monitor with Reset Switch Low cost line voltage protection for 3-phase motor systems 3-Position Reset Switch: MAN-MAN AUTO-AUTO AUTO-MAN Installation, Operation & Application

More information

SA-59. GSM Communicator. Installation Manual

SA-59. GSM Communicator. Installation Manual SA-59 GSM Communicator Installation Manual September 2009 Table of Contents Table of Contents 1. Introduction... 3 1.1 Overview... 3 1.2 Main Features... 4 2. Technical Specifications... 5 3. Installation...

More information

User s Guide. POWERVAR Single Phase Power Conditioners

User s Guide. POWERVAR Single Phase Power Conditioners POWERVAR Single Phase Power Conditioners User s Guide Industrial Conditioners GPI Series B Conditioners GPI Series 1 Conditioners 2-15 kva Single Phase Conditioners GPI Series 1 Conditioners RoHS Compliant

More information

EASON TECHNOLOGY. IO8 & IO24 Break-Out Module

EASON TECHNOLOGY. IO8 & IO24 Break-Out Module EASON TECHNOLOGY IO8 & IO24 Break-Out Module p/n 50-00180-01 Revision1.2 Eason Technology, Inc. 7975 Cameron Dr. Bldg 300 Windsor, CA 95492 Phone (707) 837-0120 FAX (707) 837-2742 http://www.eason.com

More information

MPP200 User s Manual

MPP200 User s Manual 2011 Visionary Solutions, Inc. All rights reserved. Please visit the support section of our website at www.vsicam.com for manuals, other documentation, and software downloads. Visionary Solutions, Inc.

More information

WARRANTY & LIMITATION OF LIABILITY

WARRANTY & LIMITATION OF LIABILITY MUX-2 WARRANTY & LIMITATION OF LIABILITY 1. ROTEM warrants that the product shall be free of defects in materials or workmanship and will conform to the technical specification for a period of 1 (one)

More information

I/O Expansion Box Installation & Operator s Instruction Manual

I/O Expansion Box Installation & Operator s Instruction Manual I/O Expansion Box Installation & Operator s Instruction Manual May 2004 CTB Inc. Warranty I/O Expansion Box CTB Inc. Warranty CTB Inc. warrants each new Chore-Tronics product manufactured by it to be free

More information

PSA200 User s Manual

PSA200 User s Manual 2011 Visionary Solutions, Inc. All rights reserved. Please visit the support section of our website at www.vsicam.com for manuals, other documentation, and software downloads. Visionary Solutions, Inc.

More information

DAS 9200 Mainframe System Upgrade

DAS 9200 Mainframe System Upgrade Installation Manual DAS 9200 Mainframe System Upgrade 070-8814-02 Warning The servicing instructions are for use by qualified personnel only. To avoid personal injury, do not perform any servicing unless

More information

Wall. No opening (Example: LA-030-W)

Wall. No opening (Example: LA-030-W) Thank you very much for choosing an EIZO product. Please read this User s Manual carefully to familiarize yourself with safe and effective usage procedures. Please retain this manual for future reference.

More information

CK3W-PD048 CSM_CK3W-PD048_DS_E_DITA_1_2

CK3W-PD048 CSM_CK3W-PD048_DS_E_DITA_1_2 CK3W Power Supply Unit CK3W-PD048 CSM_CK3W-PD048_DS_E_DITA_1_2 Supplies power to the CK3M Controller CK3W-PD048 Features 24 VDC input The power supply status indicator shows operating status 1 Ordering

More information

S82S (3/7.5-W Models)

S82S (3/7.5-W Models) Switch Mode Power Supply (3/7.5-W Models) CSM DS_E_4_3 Miniature DIN Rail Mounting DC-DC Power Supplies 65 mm depth enables mounting onto control panels with 100 mm depth. Inputs: 10.2 to 27.6 VDC (DC

More information

P O W E R S U P P L Y M A N U A L

P O W E R S U P P L Y M A N U A L POWER SUPPLY MANUAL Congratulations on the purchase of your new Corsair power supply. This User Agreement (the Agreement ) is a legal agreement between you ( You ), and Corsair Memory, Inc. ( Corsair ).

More information

CQM1 I/O Terminal Block Conversion Adapter. Easy and secure replacement by reusing the I/O terminal block wiring.

CQM1 I/O Terminal Block Conversion Adapter. Easy and secure replacement by reusing the I/O terminal block wiring. CQM1 I/O CSM_CJ1W-AT4 DS_E_1_1 Easy and secure replacement by reusing the I/O terminal block wiring You can replace CQM1(H) Series with CJ Series, efficiently using your assets. Time for wiring works and

More information

Installation and Operation Manual

Installation and Operation Manual Installation and Operation Manual INC PBB-24 Plus Programmable Button Box Firmware version v 3.19 Manual Update: 06/10/2008 Due to the dynamic nature of product design, the information contained in this

More information

Number of input channels

Number of input channels Safety Relay Unit (Sensor Connector Type) CSM DS_E_3_1 Less Wiring Required with Safety Light Curtain Sensor connector allows direct connection to OMRON 3SJ Safety Light Curtains with PNP outputs. Reduces

More information

PCM-7140 Pulsed Current Source Operation Manual

PCM-7140 Pulsed Current Source Operation Manual PCM-7140 Pulsed Current Source Operation Manual Directed Energy, Inc. 1609 Oakridge Dr., Suite 100, Fort Collins, CO 80525 (970) 493-1901 sales@ixyscolorado.com www.ixyscolorado.com Manual Document 7650-0031

More information

Proliphix EPA-60 Installation Guide

Proliphix EPA-60 Installation Guide Proliphix EPA-60 Installation Guide Rev 1.2 Page 2 of 5 Installation CAUTION THE EPA-60 SHOULD ONLY BE POWERED WITH THE PROLIPHIX POWER SUPPLY INCLUDED WITH THE EPA-60. DO NOT POWER THE EPA-60 WITH ANY

More information

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual Omnitron Systems Technology, Inc. 1 iconverter 19-Module Managed Power Chassis User s Manual 27 Mauchly, #201, Irvine, CA 92618 Phone: (949) 250-6510; Fax: (949) 250-6514 2 Omnitron Systems Technology,

More information

PRODUCT CONTENTS... 3 II. REQUIRED MATERIALS... 3 III. OVERVIEW... 3 IV. BENCH LAYOUT...

PRODUCT CONTENTS... 3 II. REQUIRED MATERIALS... 3 III. OVERVIEW... 3 IV. BENCH LAYOUT... IR-510 Bench 2012 Infrared Industries, Inc. 25590 Seaboard Lane Hayward, CA 94545 Toll-free phone 800.344.0321 Phone 510.782.8100 Fax 510.782.8101 www.infraredindustries.com Table of Contents I. PRODUCT

More information

Instruction Manual. CT-4 High-Current Transformer

Instruction Manual. CT-4 High-Current Transformer Instruction Manual CT-4 High-Current Transformer 070-6478-02 Copyright Tektronix, Inc. 1987. All rights reserved. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information

More information

Power Quality Recorder

Power Quality Recorder 1760 Power Quality Recorder Getting Started Manual PN 2713103 June 2006 Rev 1, 6/07 2006-2007 Fluke Corporation. All rights reserved. All product names are trademarks of their respective companies. LIMITED

More information

THERM-O-FLOW EC-20/40 Timer

THERM-O-FLOW EC-20/40 Timer Instructions THERM-O-FLOW EC-20/40 Timer 310814B EN For use with THERM-O-FLOW Hot Melt Tanks. Model 118051 EC-20 two event timer for 115 VAC and 230 VAC Model 118052 EC-40 four event timer for 115 VAC

More information

MiT. MOVING image TECHNOLOGIES INSTRUCTIONS FOR INSTALLATION, OPERATION, AND MAINTENANCE

MiT. MOVING image TECHNOLOGIES INSTRUCTIONS FOR INSTALLATION, OPERATION, AND MAINTENANCE MiT MOVING image TECHNOLOGIES INSTRUCTIONS FOR INSTALLATION, OPERATION, AND MAINTENANCE OF A-LMS 24 Architectural Lighting Management System Part number A000230-xxx Manual Version 1.0 MOVING image TECHNOLOGIES,

More information

iconverter 2-Module Power Chassis

iconverter 2-Module Power Chassis iconverter 2-Module Power Chassis User Manual 38 Tesla, Irvine, CA 92618 USA Phone: (949) 250-6510; Fax: (949) 250-6514 Page 1 Warning The operating description in this Instruction Manual is for use by

More information

Instructions. TLA5Fxxx, TLA6Fxx, & TLA7Fxx PowerFlex Field Upgrade Kits for TLA5000, TLA600, and TLA700 Logic Analyzers

Instructions. TLA5Fxxx, TLA6Fxx, & TLA7Fxx PowerFlex Field Upgrade Kits for TLA5000, TLA600, and TLA700 Logic Analyzers Instructions TLA5Fxxx, TLA6Fxx, & TLA7Fxx PowerFlex Field Upgrade Kits for TLA5000, TLA600, and TLA700 Logic Analyzers 071-0591-05 This document applies to TLA System Softwareversion 3.2 and above. www.tektronix.com

More information

PMDX-105 Quad Isolator Board

PMDX-105 Quad Isolator Board PMDX105 Quad Isolator Board User s Manual Date: 18 April 2011 PMDX Web: http://www.pmdx.com 9704D Gunston Cove Rd Phone: 1 (703) 3722975 Lorton, VA 220792366 USA FAX: 1 (703) 3722977 PMDX105_Manual_10.doc

More information

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4. Flat Proximity Sensor EK-F CSM_EK-F_DS_E Flat Capacitive Sensor with a Thickness of Only mm Flat Sensor with excellent space efficiency. (Model with built-in Amplifier is only mm thick.) Direct mounting

More information

Woolich Racing. USB ECU Interface User Guide

Woolich Racing. USB ECU Interface User Guide Woolich Racing USB ECU Interface User Guide 1) Introduction This user guide covers how to use the Woolich Racing USB ECU Interface. This includes: Connecting the USB ECU Interface into the Bike Harness

More information

It s Under Control. Installation and Operation Guide CPB-1. Control Port Connecting Block V 1.1

It s Under Control. Installation and Operation Guide CPB-1. Control Port Connecting Block V 1.1 Installation and Operation Guide 70-210043-17 V 1.1 Copyright 2008 Remote Technologies Incorporated All rights reserved. 2 DECLARATIONS 117 612 914 DECLARATION OF CONFORMITY (DOC) The Declaration of Conformity

More information

CM68 4 Channel NTSC/PAL Video Decoder

CM68 4 Channel NTSC/PAL Video Decoder CM68 4 Channel NTSC/PAL Video Decoder Technical Reference Guide PCB Rev 1.0 www.soc-robotics.com Copyright 2009. SOC Robotics, Inc. 1 Manual Rev 0.90 Warranty Statement SOC Robotics warrants that the Product

More information

Data Reporter. Installation-Operation E rev.f

Data Reporter. Installation-Operation E rev.f Installation-Operation Data Reporter 309867E rev.f Important Safety Instructions Read all warnings and instructions in this manual. Save these instructions. Part No. 246085 Records actual temperature,

More information

MPP1700 User s Manual

MPP1700 User s Manual 2011 Visionary Solutions, Inc. All rights reserved. Please visit the support section of our website at www.vsicam.com for manuals, other documentation, and software downloads. Visionary Solutions, Inc.

More information

Relay Board. User Manual. 1.0, Oct 2013

Relay Board. User Manual. 1.0, Oct 2013 Relay Board User Manual 1.0, Oct 2013 This work is licensed under the Creative Commons Attribution-Share Alike 2.5 India License. To view a copy of this license, visit http://creativecommons.org/licenses/by-sa/2.5/in/

More information

The Next-generation Sensor Networking Units That Revolutionize the Workplace from Introduction and Startup though Operation. Fiber Units.

The Next-generation Sensor Networking Units That Revolutionize the Workplace from Introduction and Startup though Operation. Fiber Units. Sensor Communications Unit CSM DS_E_1_1 The Next-generation Sensor Networking Units That Revolutionize the Workplace from Introduction and Startup though Operation Low initial cost achieved by distributed

More information

CrystalView DVI Multi INSTALLATION AND OPERATIONS MANUAL Stancliff Road Phone: (281)

CrystalView DVI Multi INSTALLATION AND OPERATIONS MANUAL Stancliff Road Phone: (281) CrystalView DVI Multi INSTALLATION AND OPERATIONS MANUAL 10707 Stancliff Road Phone: (281) 933-7673 Houston, Texas 77099 WWW.ROSE.COM LIMITED WARRANTY Rose Electronics warrants the CrystalView Multi to

More information

USER S MANUAL ENTITY. Energy Meter TRINITY. Entity Operational Manual

USER S MANUAL ENTITY. Energy Meter TRINITY. Entity Operational Manual USER S MANUAL ENTITY Energy Meter This document contains the latest technical information about ENTITY which is a micro-controller based Energy Meter. The unit is tested against latest "MTE" Standard Model

More information

OPERATING AND SERVICE MANUAL. Universal Interface Device 47

OPERATING AND SERVICE MANUAL. Universal Interface Device 47 OPERATING AND SERVICE MANUAL Universal Interface Device 47 MAGNA-POWER ELECTRONICS, INC. 39 ROYAL ROAD, FLEMINGTON, NJ 08822 May 24, 2012 SAFETY NOTICE Universal Interface Device 47 (UID46) connects

More information

DISCONTINUED PRODUCT DISCONTINUED PRODUCT

DISCONTINUED PRODUCT DISCONTINUED PRODUCT Important Safety Instructions This manual contains important safety instructions that should be followed during the installation and maintenance of this product. Please read this manual thoroughly before

More information

EPSON PreferredSM Limited Warranty Program for the Epson Stylus

EPSON PreferredSM Limited Warranty Program for the Epson Stylus Limited Warranty Program for the Epson Stylus Pro 17-inch Wide Format Printers Priority Technical Support Toll-Free Phone Number Security and Peace of Mind CPD-28163R1 Limited Warranty Program for the

More information

User Manual THREE PHASE VOLTAGE MONITOR RELAY FASEALERT-3 MODEL F3D. The best solutions for automation and protection.

User Manual THREE PHASE VOLTAGE MONITOR RELAY FASEALERT-3 MODEL F3D. The best solutions for automation and protection. SINCE 1973 User anual THREE PHASE VOLTAGE ONITOR RELAY FASEALERT-3 ODEL F3D The best solutions for automation and protection www.nassarelectronics.com Description The F3D series is a family of 3-phase

More information

XBDM. 1015LV, 1020LV, 1030LV, 1020HV Models USER & INSTALLATION MANUAL BYPASS DISTRIBUTION MODULE

XBDM. 1015LV, 1020LV, 1030LV, 1020HV Models USER & INSTALLATION MANUAL BYPASS DISTRIBUTION MODULE XBDM 1015LV, 1020LV, 1030LV, 1020HV Models USER & INSTALLATION MANUAL www.xpcc.com 2013 Xtreme Power Conversion Corporation. All rights reserved. Table of Contents IMPORTANT SAFETY INSTRUCTIONS:... 4 INTRODUCTION...

More information

Model 4001A Modular System Bin Operating and Service Manual

Model 4001A Modular System Bin Operating and Service Manual Model 4001A Modular System Bin Operating and Service Manual Printed in U.S.A. ORTEC Part No. 733740 0704 Manual Revision D $GYDQFHG0HDVXUHPHQW7HFKQRORJ\,QF a/k/a/ ORTEC, a subsidiary of AMETEK, Inc. WARRANTY

More information

PCMCIA Flash Card User Guide

PCMCIA Flash Card User Guide R R PCMCIA Flash Card User Guide For the CoreBuilder 3500 System Introduction The CoreBuilder 3500 PCMCIA Flash Card is a 20 MB flash card that you can use to save your system software. When you have saved

More information

INSTALLATION, OPERATION & MAINTENANCE CRFF Series Wall Control Console. ECM Motors. ACC1-25 (Part # ) Revision:

INSTALLATION, OPERATION & MAINTENANCE CRFF Series Wall Control Console. ECM Motors. ACC1-25 (Part # ) Revision: INSTALLATION, OPERATION & MAINTENANCE CRFF Series Wall Control Console ACC1-25 (Part # 63971-002) ECM Motors Revision: 10.01.13 Page: 2 of 11 Table of Contents Safety Precautions...3 Overview...3 Specifications...4

More information

G2 Cradles. for ipod and iphone. Installation Guide/User manual

G2 Cradles. for ipod and iphone. Installation Guide/User manual G2 Cradles for ipod and iphone Installation Guide/User manual 2 Copyrights and Trademarks Copyright 2012 Audiovox Electronics Corporation The Audiovox and Audiovox Driven by DICE Electronics logos are

More information

Zonit μats TM Users Guide μats1-lv Version 1.2

Zonit μats TM Users Guide μats1-lv Version 1.2 Zonit μats TM Users Guide μats1-lv Version 1.2 Table of Contents Product Overview...2 Pre-Installation Considerations...2 Product Features...3 Installation...4 Optional Accessories...4 μats TM Operational

More information

SP-C1 Mobile Docking Station Installation Guide

SP-C1 Mobile Docking Station Installation Guide SP-C1 Mobile Docking Station Installation Guide Box Contents After you unpack your SP-C1 Mobile Docking Station, make sure everything here is included: 1 x Docking Cradle 1 x Audio Cable 1 x Adhesive Mount

More information

ASCL1 / ASCL2 CarLink Guide for Android Users

ASCL1 / ASCL2 CarLink Guide for Android Users ASCL1 / ASCL2 CarLink Guide for Android Users 2012 Audiovox Electronics Corporation. All rights reserved. CarLink Guide for Android Users New Account Creation After having CarLink installed, follow the

More information

Install Motor Controller User Manual

Install Motor Controller User Manual Property of Motion Laboratories, Inc. Install Motor Controller User Manual 2014 Motion Laboratories, Inc. Created By: Michael Shaw Approved By: John Coppolecchia Page: 1 Page: 2 2014 Motion Laboratories,

More information

3-4 SAS/SATA II HDD Canister Entry version USER S MANUAL XC-34D1-SA10-0-R. Document number: MAN A

3-4 SAS/SATA II HDD Canister Entry version USER S MANUAL XC-34D1-SA10-0-R. Document number: MAN A 3-4 SAS/SATA II HDD Canister Entry version XC-34D1-SA10-0-R USER S MANUAL Document number: MAN-00077-A ii Preface Important Information Warranty Our product is warranted against defects in materials and

More information

PIM-Mini Pulsed Current Source Operation Manual

PIM-Mini Pulsed Current Source Operation Manual PIM-Mini Pulsed Current Source Operation Manual Directed Energy, Inc. 1609 Oakridge Dr., Suite 100, Fort Collins, CO 80525 (970) 493-1901 sales@ixyscolorado.com www.ixyscolorado.com Manual Document 7650-0007

More information

Pit Transition with 24" Fan Installation and Operators Instruction Manual

Pit Transition with 24 Fan Installation and Operators Instruction Manual Pit Transition with 4" Fan Installation and Operators Instruction Manual z Fan and Fan Framing Dimensions Shutter Fan " [8. cm] 6" [9.4 cm] 6-/4" [9. cm] Cone Fan " [5. cm] 4-/6" [88.4 cm] 75-/" [9.8 cm]

More information

TB-100 ControLynx Terminal Block

TB-100 ControLynx Terminal Block TB-100 ControLynx Terminal Block TECHNICAL MANUAL Version 1.3 September 2006 Copyright This technical manual and the equipment, firmware and software described herein are copyrighted by INTENT DIGITAL

More information

500 Business Center Drive Pittsburgh, PA USA CAGE 1BGJ7. SwitchMaster R5000 Series Ultra-Compact Ganged A/B Switching System

500 Business Center Drive Pittsburgh, PA USA CAGE 1BGJ7. SwitchMaster R5000 Series Ultra-Compact Ganged A/B Switching System Market Central www.secureswitch.com 500 Business Center Drive Pittsburgh, PA 15205 USA 412.494.2800 CAGE 1BGJ7 SwitchMaster R5000 Series Ultra-Compact Ganged A/B Switching System July, 2014 COMPLETE 2

More information

ASCL1 / ASCL2. CarLink Guide for BlackBerry Users Audiovox Electronics Corporation. All rights reserved.

ASCL1 / ASCL2. CarLink Guide for BlackBerry Users Audiovox Electronics Corporation. All rights reserved. ASCL1 / ASCL2 CarLink Guide for BlackBerry Users 2012 Audiovox Electronics Corporation. All rights reserved. CarLink Guide for BlackBerry Users New Account Creation After having CarLink installed, follow

More information

CubePro. Main PCB Replacement Guide. Prosumer 3D Printer. Original Instructions

CubePro. Main PCB Replacement Guide. Prosumer 3D Printer. Original Instructions CubePro Prosumer 3D Printer Main PCB Replacement Guide Original Instructions 1 INTRODUCTION COPYRIGHT 2014 by All rights reserved. This document is subject to change without notice. This document is copyrighted

More information

DIGITAL VOLTAGE INDICATOR

DIGITAL VOLTAGE INDICATOR DIGITAL VOLTAGE INDICATOR Instruction Manual US Patent 6,998,832 HD ELECTRIC COMPANY 1475 LAKESIDE DRIVE WAUKEGAN, ILLINOIS 60085 U.S.A. PHONE 847.473.4980 FAX 847.473.4981 website: www.hdelectriccompany.com

More information

MC5 Smart Relay Adapter

MC5 Smart Relay Adapter MC5 Smart Relay Adapter Technical Reference Guide PCB Rev 1.0 www.soc-robotics.com Copyright 2014, SOC Robotics, Inc. 1 Manual Revision 0.93 Warranty Statement SOC Robotics warrants that the Product delivered

More information

OPERATIONS MANUAL PCM-DOC

OPERATIONS MANUAL PCM-DOC OPERATIONS MANUAL PCM-DOC NOTE: This manual has been designed and created for use as part of the WinSystems Technical Manuals CD and/or the WinSystems website. If this manual or any portion of the manual

More information

OPERATING AND SERVICE MANUAL. Universal Interface Device 47

OPERATING AND SERVICE MANUAL. Universal Interface Device 47 OPERATING AND SERVICE MANUAL Universal Interface Device 47 MAGNA-POWER ELECTRONICS, INC. 39 ROYAL ROAD, FLEMINGTON, NJ 08822 May 24, 202 SAFETY NOTICE Universal Interface Device 47 (UID47) connects two

More information

zpen-1080p Features zpen-1080p Layout

zpen-1080p Features zpen-1080p Layout 1 zpen-1080p Features CMOS image sensor with Low Light sensitivity HD 1080P up to 30fps, 720P up to 60fps H.264 compression Built-in micro SD card, supports up to 32GB One button operation Easily download

More information

INSTRUCTION MANUAL IM253 R0. AquaStart COMBINATION SOFT STARTERS START-UP MANUAL

INSTRUCTION MANUAL IM253 R0. AquaStart COMBINATION SOFT STARTERS START-UP MANUAL INSTRUCTION MANUAL IM253 R0 AquaStart COMBINATION SOFT STARTERS START-UP MANUAL INDEX Power Connections...3 Basic Wiring...4 Start-Up By Voltage Ramp...5 Local / Remote Modes...6 Control and Signal Connections...6

More information

TC1880 Series. 4/5/6/8 Channel RS-232 FIBER OPTIC MICRO MUX User's Manual

TC1880 Series. 4/5/6/8 Channel RS-232 FIBER OPTIC MICRO MUX User's Manual Series 4/5/6/8 Channel RS-232 FIBER OPTIC MICRO MUX MODEL: S/N: DATE: Notice! Although every effort has been made to insure that this manual is current and accurate as of date of publication, no guarantee

More information

Brushless DC Motor Controller Specification Assembly 025A0053

Brushless DC Motor Controller Specification Assembly 025A0053 Brushless DC Motor Controller Specification Assembly 025A0053 600A0053 Rev. 2 July 28, 2004 025A0053 Brushless DC Motor Controller Data Sheet Page 1 Revision History Date Rev Description By 5/15/04 1 Initial

More information

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE IMPORTANT! Please read all the information on this sheet. SAVE THESE INSTRUCTIONS! NOTICE BEFORE USING READ INSTRUCTIONS COMPLETELY. TO BE INSTALLED BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH NATIONAL

More information

AnalogBridge Analog transmission system

AnalogBridge Analog transmission system AnalogBridge Analog transmission system Enclosure showing RTU Module and optional Power supply, External Relay User Guide Revision 1.4 Wireless Solutions at Work www.orbitcoms.com Page 1 Orbit Communications

More information

PD10. Pulse Divider Instructions PROUDLY MADE IN THE USA

PD10. Pulse Divider Instructions PROUDLY MADE IN THE USA PD10 Pulse Divider Instructions PROUDLY MADE IN THE USA ISO 001:200 Certified Company General Information General Information...Page 3 Features...Page 3 Specifications...Page 4 Installation Mounting...Page

More information

Name No. of I/O points Model Safety inputs: 12, test outputs: 4

Name No. of I/O points Model Safety inputs: 12, test outputs: 4 Safety I/O s DST1 Series CSM_DST1 Series_DS_E_7_3 Distributed Safety s That Reduce Wiring. Lineup includes four models to accommodate various I/O types and number of I/O points. Monitor the safety system

More information

TRENDnet User s Guide. Cover Page

TRENDnet User s Guide. Cover Page Cover Page Table of Contents Contents Product Overview... 2 Package Contents... 2 Features... 2 Product Hardware Features... 3 Application Diagram... 4 Installation - Hardware... 4 Adapter... 4 Fiber Cable...

More information

CM Mpixel CMOS Imaging Camera

CM Mpixel CMOS Imaging Camera CM130 1.3Mpixel CMOS Imaging Camera Technical Reference Guide PCB Rev 1.0 www.soc-robotics.com Copyright 2009. SOC Robotics, Inc. 1 Manual Rev 0.90 Warranty Statement SOC Robotics warrants that the Product

More information

G3B/G3BD. Model Number Structure. Ordering Information. Solid State Relays Model Number Legend. List of Models

G3B/G3BD. Model Number Structure. Ordering Information. Solid State Relays Model Number Legend. List of Models Solid State Relays G3@-VD CSM_G3B_G3BD_DS_E_5_1 International Standards for G3B Series, Same Profile as MK Power Relays Shape-compatible with mechanical relays. Certified by UL, CSA, and VDE (models numbers

More information

EPSON Preferred. Priority Technical Support. Toll-Free Phone Number. Security and Peace of Mind. On-Site Repair

EPSON Preferred. Priority Technical Support. Toll-Free Phone Number. Security and Peace of Mind. On-Site Repair EPSON Preferred SM Limited Warranty Program for the Epson Stylus Pro Large Format Printers Priority Technical Support Toll-Free Phone Number Security and Peace of Mind On-Site Repair CPD-20273 Please open

More information

All the registered trademarks referred to this manual are belonging to their respective companies.

All the registered trademarks referred to this manual are belonging to their respective companies. MiniDE User Manual COPYRIGHT and TRADEMARK All rights reserved by APANTA LCC, Porland, Oregon, USA. No part of this document may be reproduced in any form or by any means without written permission from

More information

Surge Protective Devices Installation, Operation and Maintenance Manual. LoadTrack LTL

Surge Protective Devices Installation, Operation and Maintenance Manual. LoadTrack LTL LoadTrack LTL Surge Protective Devices Installation, Operation and Maintenance Manual P.O. Box 3760 Winter Park, FL 32790 USA TEL: 800-647-1911 www.tpssurge.com LOADTRACK LTL INSTALLATION, OPERATION AND

More information

STYLITIS-POWER OPERATOR S GUIDE

STYLITIS-POWER OPERATOR S GUIDE STYLITIS-POWER OPERATOR S GUIDE Copyright 2008-2016, SYMMETRON Electronic Applications. Second edition in English. April 2016. No part of this publication may be reproduced, stored in retrieval system,

More information

RM3100 Rackmount Kit for the AFG3000 and AFG3000C Series Arbitrary Function Generators

RM3100 Rackmount Kit for the AFG3000 and AFG3000C Series Arbitrary Function Generators xx RM3100 Rackmount Kit for the AFG3000 and AFG3000C Series Arbitrary Function Generators ZZZ Instructions Register now! Click the following link to protect your product. www.tektronix.com/register www.tektronix.com

More information

Automated Tuner System Power Distribution Hub

Automated Tuner System Power Distribution Hub User Guide Automated Tuner System Power Distribution Hub Model MT1020B MT1020-340 (Rev B) 12/11 User Guide Automated Tuner System Power Distribution Hub Model MT1020B 2900 Inland Empire Boulevard Ontario,

More information

USB Ranger Fiber Optic USB 2.0 Extender. User Guide

USB Ranger Fiber Optic USB 2.0 Extender. User Guide USB Ranger 2224 Fiber Optic USB 2.0 Extender User Guide Thank you for purchasing the USB Ranger 2224. Please read this guide thoroughly. This document applies to Part Numbers: 00-00260, 00-00261, 00-00262,

More information

POWER SERIES Plus. 3 in 1 AC Voltage. Digital Switchboard Meter. User s Manual IM2493VVV-2

POWER SERIES Plus. 3 in 1 AC Voltage. Digital Switchboard Meter. User s Manual IM2493VVV-2 POWER SERIES Plus 3 in 1 AC Voltage Digital Switchboard Meter User s Manual General Description The POWER SERIES Plus digital switchboard meters incorporate the latest DSP microprocessor technology. Careful

More information

One Channel and Two Channel DALI Relay Device

One Channel and Two Channel DALI Relay Device Installation Guide DGOZ-RLY-10A-01 DGOZ-RLY-10A-02 One Channel and Two Channel DALI Relay Device REGISTERED DESIGN Designed in Australia to meet Australian Standards and installation conditions DIGINET.NET.AU

More information

PMDX-103. Parallel Port Isolator Board. User s Manual. Document Revision: 1.2 Date: 20 February 2007 PCB Revision: PCB-447B

PMDX-103. Parallel Port Isolator Board. User s Manual. Document Revision: 1.2 Date: 20 February 2007 PCB Revision: PCB-447B PMDX-103 Parallel Port Isolator Board User s Manual Date: 20 February 2007 PMDX Web: http://www.pmdx.com 9704-D Gunston Cove Rd Phone: +1 (703) 372-2975 Lorton, VA 22079-2366 USA FAX: +1 (703) 372-2977

More information

AhnLab Software License Agreement

AhnLab Software License Agreement AhnLab Software License Agreement IMPORTANT - READ CAREFULLY BEFORE USING THE SOFTWARE. This AhnLab Software License Agreement (this "Agreement") is a legal agreement by and between you and AhnLab, Inc.

More information