AlpTransit Gotthard AG. High current plugs and sockets
|
|
- Britney Banks
- 6 years ago
- Views:
Transcription
1 AlpTransit Gotthard AG High current plugs and sockets
2 High current plugs and sockets General information Our high current plugs and sockets are used wherever large machines and equipment with currents between 200 A and 400 A and voltages up to 1000 VAC are fitted with plug-in connections. In various designs throughout the world, on building sites, in docks and for tunnel construction. High current plugs and sockets must guarantee a high level of protection for persons and must not be unplugged while under load. Our units are therefore equipped with two pilot contacts for electrical interlocking. The contact bushings of sockets and connectors that are under load are fitted with contact cover disks that provide a reliable protection against contact with live parts. The robust construction and high corrosion protection permit use under heavy-duty conditions, and the contacts are silver-plated to provide protection against aggressive environments. Damaged contact parts (250 A/400 A) can be replaced from the front without having to remove the connected cable. Applications > movable consumer loads > on construction sites for worksite supply cabinets > on drilling plants and conveying systems > in the tunnelling and mining industry > in quarries and gravel plants > in surface mining > in high-speed trains (ICE) > in harbours and container transhipment depots > for flexible power supply at large events > in industry (e.g. for induction melting furnaces) > for test equipment Characteristics > Currents of 200 A, 250 A, 400 A > Voltages up to 1000 VAC, 50/60 Hz > Number of poles: 4-pole (3L + PEN), 5-pole (3L + N + PE) > 2 pilot contacts, lagging when closing, leading when opening > Protection class IP 67 (IP 55) > Construction according to IEC EN /VDE 0623, Part 1 > Voltage identification coding in accordance to IEC EN > Covered contacts for connectors and socket outlets > Probe-proof according to IEC EN > Very robust construction > Contact parts silver-plated > Contact parts replaceable from the front (with 250 A and 400 A) > Insertion and withdrawal aid, lockable > Wide range of plugs, appliance inlets, panel mounted sockets, wall-mounted sockets, with circuit breaker, with electrical interlock, with power switches, with earth leakage current protection > Salt-water proof models on request
3 Product lines Mains supply JW JWS JWL JWU JE JK JS JF JGU Receptacle wall-mounted socket outlet mechanically switched and interlocked Receptacle wall-mounted socket outlet electrically switched and interlocked Receptacle wall-mounted socket outlet with circuit breaker Receptacle Panel mounted receptacle Connector Plug Panel mounted inlet Inlet JW JWS JWL JWU JE JK JS JK JS JF JGU Consumer
4 Technical characteristics Finger-proof with contact cover disks The contact bushes on sockets and connectors are fitted with contact cover disks that provide a reliable protection against contact with live contact bushes. When the plug is inserted, the PE pin presses the contact cover disks to the side so that the openings become accessible. When pulling the plug out, a spring moves the contact cover disks back to their initial position. Probe-proof according to IEC EN Contacts replaceable from the front In the 250/400A units, the damaged front parts of the contacts can be replaced from the front without having to dismantle the connected conductor. < Probe-proof < Replaceable contacts Two-part silver-plated contacts The contacts comprise a rear part for the conductor connection, which remains in the socket insert and the front part that can be replaced using an Allen key. The U-shaped contacts are silver-plated as protection against aggressive environments and are self-cleaning when inserted. Silver-plated contacts >
5 < Electrical interlock < Mechanical interlock Electrical interlock All units are equipped with two pilot contacts as standard. They close with a lag when being inserted, and open with a lead when being withdrawn. High current plugs and sockets can be interlocked electrically or mechanically. Circuit: Mechanical interlock Switched receptacles have a mechanical interlock. The switch can only be switched on when the plug is inserted, and the plug can only be removed when the switch is switched off.
6 Insertion and withdrawal aid All plugs and sockets are equipped with two cam levers that serve as insertion and withdrawal aids, which can be locked in their final position using a padlock. < Cable insertion < Insertion and withdrawal aid Cable insertion for IP 67 As standard, plugs, connectors, appliance inlets and receptacles are delivered with bell-shaped cable inlets for cable diameters from 45 to 65 mm. The externally mounted tension relief clamp facilitates the connection. Metal bell-shaped cable inlets up to Ø 80 mm are available for the nominal values 250 A and 400 A.
7 Additional information Conductor cross-sections and permissible rated currents Stainless steel frame clamps permit the following conductor crosssections according to the thermal rated currents: Nominal Nominal Flexible Single and value current conductor multi-wire I th conductors 200 A 200 A 70 mm 2 70 mm A 150 mm mm A 250 A 120 mm mm A 150 mm mm A 400 A 185 mm mm A 185 mm mm 2 < Cross-section Voltage identification coding Arrangement of the PE contact bush with respect to the polarising slot for the various voltages and frequencies according to clock position, based on Table 104 from EN : L+PE 3L+PE 3L+N+PE * non-standardised positions, freely available for special applications Voltage coding >
8 Application examples Industry: Oil treatment plant Switzerland Tunnelling: Tunneling jumbo Norway Industry: Timesavers Holland Gravel works: Switzerland
Providing flexible power supply and signal connection there, where it is needed even in hazardous areas for the Zones 1and 2.
e X L i n k exlink 7-pole / 6-pole + PE for Zone 1 and Zone 21 Providing flexible power supply and signal connection there, where it is needed even in hazardous areas for the Zones 1and 2. The exlink 7
More informationTABLE OF CONTENTS. IEC and IEC Pin and Sleeve Devices. IEC and IEC Mechanical Interlocks. Manual Disconnect Switches
TABLE OF CONTENTS IEC-309-1 and IEC-309- Pin and Sleeve Devices Introduction... - Material Specifications... 6-7 North American Ratings (0 to 100 Amp)... 8-16 Accessories... 17-18 International Ratings
More information30 A / 50 A / 90 A / 150 A / 250 A
DECONTACTOR FOR INDUSTRY 30 A / 50 A / 90 A / 150 A / 250 A SAFE AND SIMPLE CONNECTION, EVEN AT 250 A SAFETY SHUTTER GRP OR METAL CASING The DS family of decontactors offer ratings from 30 to 250 A (ratings
More informationDECONTACTOR FOR INDUSTRY 30 A / 50 A / 90 A / 150 A / 250 A
DECONTACTOR FOR INDUSTRY 30 A / 50 A / 90 A / 150 A / 250 A SAFE AND SIMPLE CONNECTION, EVEN AT 250 A SAFETY SHUTTER GRP OR METAL CASING The DS family of decontactors offer ratings from 30 to 250 A (ratings
More informationSurface-Mounting Product Ranges
Introduction Overview Light signals SCHUKO socket outlets Two-circuit switches Garages, laundry rooms, laboratories and workshops are often exposed to a lot of heavy-duty activity, which includes the odd
More informationPlugs & sockets. Industrial plugs and sockets - Scame I-1 4. Industrial switched sockets - Scame I-4 5. Distribution assemblies - Scame I-6
I Product page Industrial plugs and sockets - Scame I-1 4 Industrial switched sockets - Scame I-4 5 Distribution assemblies - Scame I-6 Industrial plug adaptors - Scame I-6 Weatherproof domestic switches
More informationM12 Field Wireable Connectors. M12 CAT.6A Field Wireable Connectors. M12 Field Wireable Connectors for PROFINET
M12 Connectors Application Advantage Shielded design ETHERLINE Ethernet Cable, Connectors & Tools M12 Field Wireable Connectors Male Female Temperature Range: Max. 85 C Nominal Voltage: Nominal Current:
More information1-Conductor Female Connector with Levers Pin Spacing: mm MCS MAXI 16
-Conductor Female Connector with evers Pin Spacing: 0.6 mm MCS MAXI 6 Intuitive and tool-free lever actuation Universal connection for all conductor types Push-in termination of solid or ferruled conductors
More informationSwitches 6/1. 6/4 Introduction. 6/5 5TE8 control switches. 6/7 5TE4 8 pushbuttons. 6/9 5TE8 On/Off switches. 6/11 5TE1 switch disconnectors
6/4 Introduction 6/5 5TE8 control switches 6/7 5TE4 8 pushbuttons 6/9 5TE8 On/Off switches 4 6/11 5TE1 switch disconnectors 6 6/1 Switch to manual? Wherever electrical systems need to be switched on or
More informationB - Line Technical Data
B - Line Technical Data Technical Data Unit B - Line Nominal current A 250 315 400 Rated current A 315 380 450 Rated voltage V 1 000 Rated frequency Hz 50 / 60 Withstand voltage (1 Min / 50 Hz) V 4 000
More informationDECONTACTOR METAL 20 A/32 A/63 A/125 A/200 A
X ECONTACTOR 20 A/32 A/63 A/125 A/200 A II2 G Ex de IIC, t 1 IP65 water-and dust-tight Integrated load-break switch Locking in connected or disconnected position by keying axis 178 X TECHNIL FEATURES X1
More informationSwitch Disconnectors, Main and EMERGENCY-STOP Switches
General data Overview Siemens G 2010 1 2 3 NSE0_01931b 4 5 6 7 1 uxiliary switch (3SB for 3K; 3KX for 3KE) 2 IP20 terminal cover (Operator side) 3 3K switch disconnector 4 rcing contacts (only for 3KE)
More informationStandardized valve series MI-01 Connection pattern according to ISO 5599/1, size 1, 5/2- and 5/3-way NG and 1700 Nl/min (1.636 and 1.
Standardized valve series MI-01 Connection pattern according to ISO 5599/1, size 1, 5/2- and 5/3-way NG 9 1610 and 1700 Nl/min (1.636 and 1.728 Cv) Order code Series and function 1) Plug socket see page
More information3081 Test Leads Test Leads Test Leads
3081 Test Leads 4 mm safety plug system PVC-lead highly flexible, 0.8 mm 2 Safety plug at both ends Straight/angled, complying with Standard cable length: 500/1000/2000 mm Test Leads with Silicon-Isolation
More informationmodlink msdd Front panel interfaces
Tight and with full visibility The connecting mechanism of the Modlink MSDD with integrated locking mechanism allows the components to be used under protection class IP65. This protection class prevents
More informationIT power distribution Power distribution units (PDU) Basic. Versions available:
IT PDU Basic 1 U With its IT PDU Basic 1 U, BACHMANN provides a huge choice of PDUs in a high-quality aluminium profile. With their extremely compact size of just 1 height unit, mm in depth and 1" in width,
More informationDECONTACTOR METAL 20 A/30 A/50 A/90 A
DN DECONTACTOR METAL 20 A/30 A/50 A/90 A IP55 automatic (IP66/67 optional) AC-22 and AC-23 Integrated Breaking Capacity (IEC/ EN 60947-3) Impact resistant metal casing - IK09 Suitable for heavy industry
More informationPin & Sleeve. EUREKA-HD Series WATERPROOF SPLASHPROOF. Heavy duty Industrial Wiring Devices
Pin & Sleeve EUREKA-HD Series Heavy duty Industrial Wiring Devices WATERPROOF SPLASHPROOF Pin & Sleeve PIN & SLEEVE DEVICES EUREKA-HD Series Watertight and Splashproof IEC REFERENCE STANDARDS IEC 60309-1
More informationDISCONNECTABLE MOTOR SWITCH AC-3 UP TO 45 kw
DB DISCONNECTABLE MOTOR SWITCH AC-3 UP TO 45 kw 7.5 kw/22 kw/45 kw AC-3 visible switch for motors Standard IP66/IP67 Impact resistant metal casing - IK09 LOTO compliant 70 DB TECHNICAL FEATURES AC-3 motor
More informationtopter SERIES ACTIVE PROTECTION Leading Electrotechnology
topter SERIES ACTIVE PROTECTION Leading Electrotechnology topter series Active protection Industrial sockets splash proof and watertight IP44, IP66/IP67 product specifications Conformity to standards EN
More informationATX MRE Series 16 and 32 Amp Multiple Socket Outlets Stationary and Portable. Increased Safety
Applications Plugs and sockets are used with portable or stationary electrical equipment such as: Lighting systems Conveyors Heaters Motor generators Air conditioning equipment Compressors Pumps For use
More informationTechnical data: Pin Spacing
282 Female Connectors, Double-Row Pin Spacing: 3.5 mm Universal connection for all conductor types Unique, compact, double-row connector system for conductor cross sections up to 1.5 mm 2 High-density,
More informationFerrous metal (The sensing distance decreases with non-ferrous metal.) Power supply voltage (operating voltage range)
Description The sensors provide excellent results even with difficult-to-detect objects, e.g. small or thin parts, wires or bright metals. A variety of types cover a wide range of individual requirements
More informationM C. Ex d M-0... control, monitoring and signalling devices
Ex d M-0... control, monitoring and signalling devices M-0 M-0 series control, monitoring and signalling devices are installed as external accessories on Cortem 'Ex d' enclosures used in any industrial
More informationMRE Series 16 and 32 Amp Multiple Socket Outlets Stationary and Portable. Increased Safety
MRE Series 16 and 32 Amp Multiple Socket Outlets Applications Plugs and sockets are used with portable or stationary electrical equipment such as: Lighting systems Conveyors Heaters Motor generators Air
More informationv1.0 JL10 Series Circular Waterproof Connector Connector Training Module Copyright 2015 JAE Electronics, Inc.
v1.0 JL10 Series Circular Waterproof Connector Connector Training Module Copyright 2015 JAE Electronics, Inc. JAE JL10 Series Circular Waterproof Connector Application Examples Industrial machineries Servo
More informationpoles type cable gland type or connection color approvals order no.
DIN 43650-A/ISO 4400 GDM Series Cable socket, self-assembly Product description durable angled connectors, dust and splash protected (IEC 60529 IP 65) vibration-proof locking using a central screw available
More informationMEASURING AND TESTING INSTRUMENTS
MEASURING AND TESTING INSTRUMENTS Whether measuring temperature, current or voltage testing the right measuring tool can facilitate the everyday work. If one wants to perform several measuring tasks at
More informationConnector System for Fluorescent Lighting Fixtures. Connectors for In-Line Mounting of Fluorescent Lighting Fixtures. Fully Polarized Connectors
Connector System for Fluorescent Lighting Fixtures Connectors for In-Line Mounting of Fluorescent Lighting Fixtures Fully Polarized Connectors Luminaire Disconnect Connectors Pluggable Lighting Connectors
More information3RV1 Circuit-Breakers
SIRIUS 3R Description Mountable accessories 3RV1 Circuit- Breakers Circuit-breaker S00 with mountable accessories 3 2 1 5.1 NSK-7715a 4 Circuit-breaker S0 with mountable accessories 1 7 3 5.2 2 6 NSK-7716a
More informationAPS4 Inductive Proximity Sensors
APS4 Inductive APS4-S-E-D APS4-S-E2-D APS4-M-E-D APS4-M-E2-D Compact x27 mm plastic DC 4 models available Compact polycarbonate housing; comes with mounting plate High-frequency oscillation type DC 3-wire,
More informationSYSTEM COMPONENTS MARCH 2016
SYSTEM COMPONENTS MARCH 2016 SYSTEM COMPONENTS STATIONARY SOCKET OUTLET COMBINATIONS Modular System 4 The 7 Key Advantages 6 Comparison of sizes and dimensions 9 Wall-mounted Distributor Boxes (plastic)
More informationChameleon Stand-alone
Quick Installation Guide Installation and Commissioning Chameleon Stand-alone Power Supply Module, 48 VDC, 650W, HE, IP65 Low Power Outdoor Applications 356849.03 Introduction Warnings..., page 3 Tools
More information78 Series Electromechanical Relay Selection Guide
78 Series Electromechanical Relay Selection Guide Specification 781 Series 782 Series 783 Series 784 Series Coil Voltages Configuration SPDT DPDT 3PDT 4PDT Contact Rating 15A 15A 15A 15A Base Socket 5
More informationProduct Details. Contents. Features and Mounting Options for SUNNY STRING-MONITOR SSM24-11
Technical Information Product Details Features and Mounting Options for SUNNY STRING-MONITOR SSM24-11 Contents The Sunny String Monitor SSM24 11 is specifically designed for monitoring large PV generators.
More informationProduct and functional description
Product and functional description The RS 525/23 Universal Dimmer is a KNX device with one dimmer output. The device is installed in an AP 118 Control Module Box or an AP 641 Room Control Box. The bus
More informationOwner s Manual. Isolate. Restore. Inspire! Power Conditioners Audio / Video Power Isolation Units Rack Mount / Consumer Series
Owner s Manual 19 Pro Series Rack Mount (RK) Faceplate Isolate. 17 Consumer Series (C) Faceplate Available in Black (B) and Silver (S) Colours Restore. Power Conditioners Audio / Video Power Isolation
More informationConveyor Belt Alignment Switches from IDEM
Conveyor Belt Alignment Switches from IDEM Data Sheet Die-Cast Models Python Line Series Stainless Steel Models Using Conveyor Belt Alignment Switches Application: Conveyor Belt Alignment switches are
More informationConnect - Contact - Control. Connectors according to UIC VE EP Series. F 121.en
Connect - Contact - Control Connectors according to UIC 541-5 VE 123 F 121.en 2 Connector to UIC standard 541-5 VE, The connector is designed in accordance with the specifications of the international
More informationPressure switches and thermostats, types KP and KPI
Features Wide regulating range Small dimensions Space-saving - easy to install in panels Ultra-short bounce time. Limits wear to an absolute minimum and increases reliability. Electrical connection at
More informationODU MINI-SNAP PC Product Description. ODU MINI-SNAP PC: The Connector with Push-Pull-Locking in Plastic
ODU MINI-SNAP PC Product Description ODU MINI-SNAP PC: The Connector with Push-Pull-Locking in Plastic Cylindrical Connectors are generally available with several locking mechanisms: The most frequently
More informationfor a perfect electrical installation. The range of rail-mounted terminal blocks
The range of rail-mounted terminal blocks for a perfect electrical installation. The range of rail-mounted terminal blocks for a perfect electrical installation. The new standard for rail-mounted terminal
More informationSafety switches for hinged doors
C Safety switches for hinged doors Selection diagram FR FM FX FZ FK 18 7 9 snap action overlapped CONTACT BLOCKS 21 NC 1NO+ CONDUIT ENTRIES Threaded conduit entries (standard) With cable gland assembled
More informationSwitch rated plugs and receptacles with NEMA 4X protection
DSN Features and Ratings p. 22 DSN20 p. 23 DSN30 p. 25 DSN60 p. 27 Spare parts p. 29 Dimensions p. 31 21 Switch rated plugs and receptacles with NEMA 4X protection DSN Series products are switch and hp
More informationConnector series UIC 558 VE R115. F 120.en
Connector series UIC 558 VE R115 4 52 F 0.en UIC 558 VE series connector The connector complies with the requirements of UIC 558 VE (up to 1994: UIC 58 VE). It connects lines used for the: remote control
More informationHan-Brid. Contents Han-Brid Features Han-Brid Data interfaces Han-Brid Overview Han-Brid Cu
Contents Page Features... 19.02 Data interfaces... 19.03 Overview... 19.04 Cu... 19.06 F.O.... 19.08 Quintax 3 A... 19.10 RJ45 C... 19.12 USB / FireWire... 19.14 Han 4 A SC... 19.16 Hoods/Housings... 19.18
More informationSAFETY LOCKING DEVICES
L200 Heavy-Duty L200 Safety Locking Device on a very large gate in a logistics operation with forklift traffic The L200 Safety Locking Device designed for highly demanding applications is predestined for
More informationSafety Systems Safety Integrated
3SE2 / SE3 Molded plastic /metal enclosure with separate actuator Application Safety interlock switches with separate actuator are used where the position of doors, covers or safety screens must be monitored
More informationThermal-Magnetic Circuit Breaker 2216-S
Thermal-Magnetic Circuit Breaker 226-S Description One and two pole thermal-magnetic circuit breaker in compact design with slide actuator, trip-free mechanism, various trip characteristics and optional
More informationTable of Contents Quick Install Guide page Introduction Safety Rack System Precautions ESD Precautions...
Table of Contents Quick Install Guide page 1 EN English Table of Contents 1. Introduction... 2 1.1 Safety... 2 1.2 Rack System Precautions... 2-3 1.3 ESD Precautions... 3... 3 1... 3 2 Fitting PSU s...
More informationProduct and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005
Product and Applications Description Application Programs The application programs of the dimmer UP 525/01 consist of two elements: the actuating and the sensor program element. The tasks actuating program
More informationCompact plugs and receptacles standard or high temperature rated
PN Features and Ratings p. 118 PN20 p. 119 PN20 High Temp p. 121 Spare parts p. 123 Dimensions p. 125 Compact plugs and receptacles standard or high temperature rated PN Series plugs and receptacles offer
More informationHan PCB termination. Han-Fast Lock PCB adapter for Han DD PCB adapter for Han DDD module
Han termination Contents Page Han-Fast Lock... 20.11 adapter for Han DD... 20.13 adapter for Han DDD module... 20.16 adapter for Han 40 A Axial module... 20.18 adapter for Han E... 20.20 adapter for Han
More informationSmall Circular Connector. JN1/JN2 Series. Cap
COMPONENTS PRODUCT INFORMATION RoHS Compliant NEW Small Circular Connector JN1/JN2 Series CONNECTOR MB-0054-10 June 2012 Angle Plug [JN1] [JN2] [JN1] [JN2] Straight Plug Cable Connecting Individual Plug
More informationProduct and functional description
Product and functional description The UP 525/13 Universal Dimmer is a KNX device with one dimmer output. The device is installed in a flushmount wall box (60 mm Ø, depth 60 mm) or an installation box.
More informationEFFICIENT AND STABLE POWER DISTRIBUTION Workside power distribution boards
0 - Workside power distribution boards EFFIIENT AND STABLE POWER DISTRIBUTION. Workside power distribution boards from : These robust, electrical jack-of-all-trades meet every requirement for demanding
More informationLine Impedance Stabilization Network (LISN)
Model 3816/2 Line Impedance Stabilization Network (LISN) User Manual ETS-Lindgren Inc. reserves the right to make changes to any product described herein in order to improve function, design, or for any
More informationIndustrial Ethernet Panel-Mount Adaptors for PROFINET or EtherNet/IP Applications
Industrial Ethernet Panel-Mount Adaptors for PROFINET or EtherNet/IP Applications Type 0981 ENC 100 RJ45/M12 adaptor, female receptacle connector M12, D coding, chassis side thread PG 9, RJ45 female connector,
More information63 to 125 A. Functions. Conformity standards. General characteristics. Changeover switches SIRCO VM1 changeover switches.
comut_004_a_1_cat Changeover switches switches 63 to 125 A switches are manually operated three or four pole switches. They provide, source inversion or switching under load between two low voltage power
More informationSolConeX plugs and sockets. our new global player
SolConeX plugs and sockets our new global player 2 SolConeX the new generation of plugs and sockets 3 SolConeX, the new generation of explosion protected plugs and sockets from R.STAHL, is the most up-to-date
More informationAmphenol Miniature Cylindrical Proprietary/MIL-C-26482, Series 1
Amphenol Miniature Cylindrical Proprietary/ PT PT-SE SP 3 DESIGN CHARACTERISTICS Medium size, widely used cylindrical Operating voltage to 1,000 VAC (RMS) at sea level Environment resistant Quick positive
More information07. har-link Interface Connectors
. Interface Connectors The highest data rates in combination with perfect shielding characterize the connector. This way data can be passed on optimally within the control cabinet. The locking mechanism
More information4 C/O. Contact material AgNi AgNi gold-plated Nominal contact current Inrush current
Quattro-Relais Quattro Relay 4 Quattro Relay 4A4 Standard type / With LED and protection diode on request Quattro-Relais Order Code Order Code Quattro Relay 4 A 4 4 V DC N Type of relay Quattro Relay 4
More information194E FA 32 E P11 P11 6
Bulletin E IEC Load Switches, A Product Selection/Catalog Number Explanation Bulletin E Enclosed Disconnect Load Switches with R Handles (with Defeater, suitable for padlocks) E-FA Painted Steel Enclosure
More information07. har-link Interface Connectors
. Interface Connectors The highest data rates in combination with perfect shielding characterize the connector. This way data can be passed on optimally within the control cabinet. The locking mechanism
More informationsonnen Installation Practical
sonnen Installation Practical sonnen Components sonnenbatterie eco 8.0 Single Phase System Components 4 sonnenbatterie eco 8.0 Single Phase System Components 5 sonnenbatterie eco 8.0 Single Phase System
More informationVandal-proof latching action switch MSM LA
Product Manual Vandal-proof latching action switch MSM LA CONTENTS 1 PRODUCT DESCRIPTION... 2 2 TECHNICAL DATA AND DIMENSIONAL DRAWINGS... 2 2.1 Technical Data... 2 2.2 Dimensional Drawings... 5 2.3 Hole
More informationUser Guide Automatic Transfer Switch (ATS)
User Guide Automatic Transfer Switch (ATS) V.1.0 Table of Contents 1. Introduction... 2 2. Product Overview... 2 3. Important Safety Warnings... 3 4. Operation Indicators & Status... 3 5. Installation...
More informationMSR 2400W. Multi purpose Power System for Telecom and Industrial Applications. Nominal Output Voltage. Voltage Setting Range
MSR 2400W Multi purpose Power System for Telecom and Industrial Applications 2400 W modular system All voltages available 0 144VDC per module U and I adjustable from 0 to max value Hot-swap plug-in modules
More information07. har-link INTERFACE CONNECTORS
. INTERFACE CONNECTORS The highest data rates in combination with perfect shielding characterize the connector. This way data can be passed on optimally within the control cabinet. The locking mechanism
More informationProgram B3 318 Ø 22,5mm. Push Buttons 319 EMERGENCY STOP Buttons 320 Key Operated Rotary Switches 320
Push Buttons Index Page Program B3 318 Ø 22,5mm Push Buttons 319 EMERGENCY STOP Buttons 320 Key Operated Rotary Switches 320 Rotary Knobs and Swing Knobs 321 Illuminated Rotary Knobs and Swing Knobs 321
More informationGHA. Gas-Insulated Circuit-Breaker Switchgear Unit up to 40.5 kv. Gas-Insulated Switchgear. Customer Benefits
01 Gas-Insulated Circuit-Breaker Switchgear Unit up to 40.5 kv PM103255 Energy supply security is our permanent challenge. At Schneider Electric, we are constantly developing and improving our products
More informationSECTION WIRING DEVICES PART 1 - GENERAL. A. Drawings and Division 1 Specification Sections, apply to this Section.
SECTION 16140 WIRING DEVICES 1.01 RELATED DOCUMENTS PART 1 - GENERAL A. Drawings and Division 1 Specification Sections, apply to this Section. 1.02 SUMMARY A. This Section includes receptacles, connectors,
More information4.5 Components for TV/SAT, telephone installations and Category DATATEL Series - TEL DATATEL Series - CAT5 DATATEL Series - TV/SAT
Components for TV/SAT, telephone installations and Category 5 DATATEL - TEL DATATEL - CAT5 DATATEL - TV/SAT 7 7 Components for telephone installations FIXED TELEPHONE SOCKETS Type RJ Socket 6/ surface
More informationCROWN LINE Power Bus Bar Distribution System
COWN LINE Power Bus Bar Distribution System COWN LINE Power Bus Bar Distribution System The pluggable bus bar system Currents up to 300 Amps Up to 2 meters in length Pluggable breakers VDE finger proof
More informationInstallation Manual INTELLIGENT SERVER. Model name: BMS-LSV6UL
Model name: BMS-LSV6UL INTELLIGENT SERVER Thank you very much for purchasing this TOSHIBA INTELLIGENT SERVER. Please read this manual carefully beforehand for proper installation of the SERVER. NOTE This
More informationERNIPRESS Trapezoidal-Connectors Series TMC
ERNIPRESS Trapezoidal-Connectors Series TMC Subminiatur-D Connectors to DIN 41 652/IEC 807-3 with Press-fit zone General Solderless press-in technology for connectors in bus systems permits rationalized
More informationElectrical Interconnection
Electrical Interconnection Edition 208/ Rail-Mount Terminal Block Systems Full Line Catalog, Volume Edition 207/208 PCB Terminal Blocks and Connectors Full Line Catalog, Volume 2 Edition 207/208 2 Automation
More informationAuxiliary/Pilot Contacts p. 189 Additional Watertightness p. 190 Lid Configurations p. 191 Plug Caps p. 192 Pawl Options p. 193 Auxiliary Switches p.
Accessories & Options 187 Auxiliary/Pilot Contacts p. 189 Additional Watertightness p. 190 Lid Configurations p. 191 Plug Caps p. 192 Pawl Options p. 193 Auxiliary Switches p. 194 Self-Ejecting Devices
More informationAccessories & Options
Accessories & Options 197 ACCESSORIES & OPTIONS Auxiliary / Pilot Contacts p. 199 Additional Watertightness p. 200 Lid Configurations p. 201 Plug Caps p. 202 Pawl Options p. 203 Auxiliary Switches p. 204
More informationMMLB 01/MMLB 02 Multi-finger Test Plug/ Single-finger Test Plug Technical Data MMLB_EN_TD_A
AUTOMATION MMLB 01/MMLB 02 Multi-finger Test Plug/ Single-finger Test Plug Technical Data MMLB_EN_TD_A GRID Note: The technical manual for this device gives instructions for its installation, commissioning,
More informationWhen any of the following symbols appear, read the associated information carefully. Symbol Meaning Description
Uni-I/O Wide Modules Installation Guide UID-W1616R, UID-W1616T Uni-I/O Wide is a family of Input/Output modules that are compatible with the UniStream control platform. Wide Modules are 1.5 times as wide
More informationAdvantage Series Switch-Rated IEC Pin & Sleeve. Highest Performing IEC Pin & Sleeve Connections for the Most Demanding Environments
Advantage Series Switch-Rated IEC Pin & Sleeve Highest Performing IEC Pin & Sleeve Connections for the Most Demanding Environments The Evolution of Pin & Sleeve Hubbell is the Only IEC 60309 Pin & Sleeve
More informationPHOENIX CONTACT Pin. SUBCON-PLUS M ARCNET, MULTI/MININET (B&R), SYSTEM 2003 (B&R), P-NET SUCONET K1, K2 (EATON/Moeller),
Fast connector with screw terminal block connection for fieldbus systems Data sheet 00287_en_02 PHOENIX CONTACT 207-04-2 Description The SUBCON-PLUS/... D-SUB series is specifically designed for use in
More informationFor situations susceptible to interference and safety-related applications
IEC 60947-5-2 Product description Multi-pole shielded circular connectors. Design according to DIN 43651, all-metal construction, used for control and measurement systems. Connection of shielded cables
More informationAccessories & Options
Accessories & Options 197 ACCESSORIES & OPTIONS Auxiliary / Pilot Contacts p. 199 Additional Watertightness p. 200 Lid Configurations p. 201 Plug Caps p. 202 Pawl Options p. 203 Auxiliary Switches p. 204
More informationPCB plug-in connectors on a new scale
PCB plug-in connectors on a new scale SKEDD direct plug technology revolutionises connection technology Pressfitting, wave soldering, THR soldering, and SMD soldering are all well-established processes
More informationThree Phase Residential Solution for Australia, System Design and Installation Guidelines
Three Phase Residential Solution for Australia, System Design and Installation Guidelines This document describes how to design and install SolarEdge three phase inverters for residential installations.
More informationR u b b e r d i s t r i b u t o r
Rubber distributor The modular rubber distributor series We live in a fast-moving time. It is also frequently necessary to make modifications to power distribution systems. Power distributors used in industrial
More informationTECHNICAL DATASHEET Incremental Encoder RI 58-F
Incremental hollow shaft encoder Up to 10 000 ppr Through hollow shaft and hubshaft up to 12 mm (14 mm optional) Optimized stator coupling Applications: Feedback for asynchronous motors, industrial applications
More informationalid portable power cart epcc panel ccts EPCC-60 40" 60A, 120/208V 3PH 24 EPCC " 100A, 120/208V 3PH 24
portable power cart epcc Features/Specifications 12GA Steel construction CSA Type 3R rated Pin & Sleeve inlet connector Pad-lockable door Up to12 receptacles Cut-out in bottom to provide while-in-use Polyurethane,
More information1/2 Introduction. SIMBOX LC 1/7 Introduction 1/8 Flush-mounting and surfacemounting. 1/9 Dimensional drawings
Siemens AG 200 ALPHA SIMBOX Small Distribution Boards /2 Introduction /2 Introduction /3 Flush-mounting and hollow-wall distribution boards /4 Hood-type distribution boards /5 Accessories /6 Dimensional
More informationData sheet. HDC insert HDC HQ 7 FC
The HQ series - big features in a compact design The electrical values speak for themselves. The standard HE crimp contacts can also be used here. The wire connection level is designed as a crimp contact
More informationDC-Switch With G20S/G20. next
DC-Switch With knife contacts G2S/G2 www.krausnaimer.com next Content The most important technical data: G2S / G2... 3 Electrical data of ON/OFF-Swichtes: G2S / G2... 4 Electrical data of Change Over Switches:
More informationLightning and Surge Arresters
Lightning and Surge Arresters 5/4 Product overview 5/5 Lightning arresters, requirement category I (B) 5/6 Combined arresters, requirement category I (B) and II (C) 5/7 Single-pole surge arrester, requirement
More informationVM series. features. web contents. code description. available models. inductive sensors. Cylindrical M12 in AC B H
VM series Cylindrical M2 in AC inductive sensors warranty features warranty Output: cable and M2 plug cable exit Models with 2 wires IP67 protection degree Multivoltage 20...253 Vac web contents Application
More informationSensor Accessories Retroreflectors and Retroreflective Tape Sensor Mounting Brackets Sensor Accessories. 52.
Retroreflectors Sensor Accessory AC Sensor Tester/Demonstrator Pilot Device E65 Control Unit.1 Retroreflectors and Retroreflective Tape Product............................................. 414 Application..........................................
More informationOperating Manual High current connectors 200 A, 250 A, 400 A
Operating Manual High current connectors 200 A, 250 A, 400 A Rauscher & Stoecklin AG Reuslistrasse 32 CH 4450 Sissach Telefon: +41 61 976 34 66 Telefax: +41 61 976 34 22 E-Mail: info@raustoc.ch Internet:
More informationK1K015NZ4 cam stepping switch - 2-pole A - screw mounting
Characteristics cam stepping switch - 2-pole - 60-12 A - screw mounting Complementary Number of steps 5 Main Range of product Product or component type Component name [Ith] conventional free air thermal
More informationProduct and functional description
Product and functional description The RS 520/23 shutter / blind actuator is a KNX device with one relay output. The device is installed in an AP 118 Control Module Box or an AP 641 Room Control Box. The