INSTRUCTION MANUAL DIGI-LOCK. Keyless Entry System. Installation. Programming. Troubleshooting. BASE Industries
|
|
- Cora Barton
- 6 years ago
- Views:
Transcription
1 INSTRUCTION MANUAL DIGI-LOCK Keyless Entry System Installation Programming Troubleshooting BASE Industries
2 45 Pomona Rd. Corona, CA Revision F TABLE OF CONTENTS OWNER REGISTRATION CARD INTRODUCTION Thank you for purchasing a BASE Industries Digi-Lock access system. Product Overview 1 Please complete the following information and return this card by mail to System Dimensions.. 1 BASE Industries to properly register your new access system. Safety Guidelines.. INSTALLATION IMPORTANT NOTICE Mounting The System.. Never allow this device to be installed within reach of an automatic vehicular gate operator Grounding The System. or gate. It must be mounted in such a way that the user cannot come into contact with the Powering The System gate or the gate operator when the device is used. We recommend that the unit be installed Basic Wiring Connections 3 a minimum of 10 feet away from any gate or gate operator. Wiring Diagrams. 3 Circuit Board Diagram.. 4 Auxiliary Open Wiring Connections 4 Owners Name: Time Clock Wiring Connections.. 4 Slave Keypad Wiring Diagram. 5 Mailing Address: City: State: Zip: Programming Entry Codes.. 6 Erasing Individual Entry Codes 7 Phone: Erasing All Entry Codes... 7 Programming Relay 1 Activation Time... 8 Programming Relay Activation Time.. 8 System Address: Programming Strikes And Out Feature 9 Programming Entry Code Length. 9 City: State: Zip: Program Access Code (PAC). 10 Verifying Program Access Code (PAC). 10 System Model: TROUBLESHOOTING Serial Number: Date Purchased: Troubleshooting Tips. 11 Purchased From: PARTS LIST Parts List & Diagram. 1 Installed By: IMPORTANT NOTICE If this system is used to activate an automatic vehicular gate operator, it must Please return this Owner Registration Card by mail to: be mounted in such a way that the user cannot come into contact with the gate or the gate operator when the device is used. We recommend that the unit be
3 installed a minimum of 10 feet away from any gate or gate operator. BASE Industries 45 Pomona Rd. Always instruct the end user on safe, proper use of this device. This manual Corona, CA is property of the end user. It must be left in their possession upon installation. Always disconnect power prior to performing service on this system. PARTS LIST INTRODUCTION Product Overview Item Part No. Description Quantity Retail Price The BASE Industries Digi-Lock keyless access system offers a wide range 10 DL Pin Keypad 1 $90.00 of standard features including, built-in lighting, two relays, time clock capability, relay hold feature, and 4 or 5 digit entry codes. The Digi-Lock 15 DL-015 Key-Pad Sub-Plate 1 $9.00 series is housed in a rugged steel box and uses a stainless steel faceplate with a metal keypad to make it vandal resistant. The built-in lighted hood 0 BI-00 Nut - 8/3 8 $1.10 makes the Digi-Lock series ideal for indoor and outdoor applications With a wide range of standard features, the Digi-Lock series is the most 5 BI-05 Key Lock Assembly 1 $10.00 durable keyless access system on the market today. 30 BI-030 Light Socket 1 $6.00 Built-in Hood Rugged Steel 35 BI-035 Light Bulb 1 $ BI-040 Lexan Cover 1 $4.00 Metal Key pad With Light Housing Two Relay s 50 DL-050 Circuit Board - Master 1 $13.00 Relay Hold Open 55 DL-055 Circuit Board - Slave 1 $69.00 Entry Codes 4 or 5 Digit Feature 75 DL-075 Faceplate 1 $80.00 Hinged Front Feature 100 BI-100 Back Box 1 $80.00 Door Strikes and Out 150 BI-150 Power Transformer 1 $4.00 1VAC-0VA System Dimensions 00 DL-00 Instruction Manual 1 $.00 BACK VIEW SIDE VIEW 4 7/8 4 SYSTEM INFORMATION For quick reference, record the system's serial number and PAC below: Mounting Holes Qty. 4
4 (Serial ) (Revision Letter) 6 3 Wiring Knock-Out 6 (Current PAC) 3 3 Page 1 Page 1 INSTALLATION TROUBLESHOOTING Mounting the System The following guidelines should be followed when mounting the system: 1. Carefully remove the front faceplate and circuit board from the back box to prevent damage to the electronics.. Place a screwdriver on the knockout of the back box, from the outside of the box, and remove using a hammer and screwdriver. 3. Bolt the back box to a gooseneck using the 3" x 3" hole pattern. 4. If the back box mounting holes are not used, fill the holes with a sealant to prevent water from entering the box. 5. Re-attach the front face plate and electronics to the back box. Always seal mounting holes to prev ent water from entering the box. Grounding the System It is important to properly ground the system during installation. An improper ground or static electricity may damage the system and will void the warranty. To properly ground the system: Troubleshooting Tips Symptom Solution Keypad is 1. Check power. Must have 1 VAC or 1 VDC Dead. Check the keypad connection. System Will 1. Check power. Must have 1VAC or 1 VDC Not Light. Check light bulb for tight fit in light socket. 3. Check light bulb. May be burnt out. Cannot Access 1. Check the Program Access Code. (PAC). Program Mode. Check the power. Must have 1VAC or 1VDC. 3. Check the keypad connection. 1. An invalid entry code has been entered. 1 Long Beep. An invalid programming entry has been made. 1. An entry code already in memory is being Long Beeps programmed into the system again.. An entry code not in memory is being erased. 1. Exiting the programming mode. 3 Short Beeps 1. Always discharge any static before handling the circuit board.. Attach a 1 AWG ground wire from the system to a good ground point within 1 feet. Mounting posts set in concrete are not a sufficient ground. Good grounds include 10 ft. grounding rods, grounded metal conduits, and grounds at electrical panels. 3 Long Beeps 4 Long Beeps 1. Entry code memory is full. 1. System has just been reset or powered up. 3. In areas prone to lightning and power fluctuations, additional protection such as surge suppressors are recommended. Powering the System 10 Short Beeps accepted. 1. Access Granted. A valid entry code has been
5 Powering the System It is important to properly power the system with a good power source. To properly power the system: 1. Provide power from a dedicated source.. Use the 1 VAC, 0va transformer supplied with the system. 3. Use the following guide to determine the proper wire size based upon the distance from power source to the system. Factory Settings Listed below are the factory settings for the Digi-Lock: Function Factory Setting Program Access Time Power Wire Size Guide Relay Default Time 10 Seconds 18 AWG 75 Feet Strikes & Out Feature 5 Incorrect Entry Codes 16 AWG 150 Feet Entry Code Length 4 Digits 14 AWG 50 Feet Page 1 AWG 500 Feet Page 11 INSTALLATION Basic Wiring Configurations Program Access Code (PAC) Each system is equipped with two relays that may be used to control a gate, door strike, The Program Access Code (PAC) is a 6 digit number used to gain access to the programming mode. The factory setting is for each system. To change the PAC: 1. Press. Press (or new PAC) Response BEEP! 3. Press BEEP! 4. Press (new PAC) magnetic lock, or other device. Refer to the diagrams below when using these configurations. (See page 4 for terminal descriptions.) Gate Operator Control 5. Press *** See Important Safety Notice; Inside Cover of this Manual *** Response BEEP! BEEP! 6. Press 0 Then BEEP! PROGRAM COMPLETE Verifying the Program Access Code (PAC) To verify the PAC: 1. Press 9 Digi-Lock Power 1V Common Normally Open Electric Door Strike Control Common Normally Open Gate Operator Power 1. Connect COM1 to the Gate Operator Common Input.. Connect NO1 to the Gate Operator Open Input. 3. Use at least 18 AWG or larger wire. Use the supplied transformer. DO NOT use power from the Gate Operator Circuit Board! 1. Connect NO1 to the Electric Strike power source.. Connect COM1 to the Electric Strike Common Input. 3. Connect power source to Electric Strike power input. 4. A separate power supply must be used to power the Electric Strike.. Press (or new PAC) Door Strike Power Digi-Lock Power 1V Door Strike
6 3. Press 4 4. Press (new PAC) Digi-Lock Power 1V Magnetic Lock Control Common Magnetic Lock 5. Press Response BEEP! BEEP! Normally Closed Power 6. Press 0 Then BEEP! PROGRAM COMPLETE Digi-Lock Power 1V Magnetic Lock Power 1. Connect NC1 to the Magnetic Lock power source.. Connect COM1 to the Magnetic Lock Common Input. 3. Connect power source to Magnetic Lock power input. 3. As shown, a separate power supply must be used to power the Magnetic Lock. Page 10 Page 3 INSTALLATION Circuit Board Diagram and Terminal Descriptions COM 1 NC 1 NO 1 COM NC NO Ground Screw All of the BLUE Terminal Blocks simply lif t of f of the Slav e Key pad Terminals (See page 5 f or connections) Serial Number and Rev ision Letter are Under Slav e Key pad Terminal Block Programming the "Strikes and Out" Feature The "Strikes and Out" Feature tells the system how many incorrect entry codes may be entered within a three minute period before the system deactivates for three minutes. When the "Strikes and Out" count has been reached, all keypad input including access to the programming mode will be ignored for three minutes. The "Strikes and Out" count is cleared when a valid entry code is entered or the system has not had any input for 60 seconds. The factory setting is five incorrect entry codes allowed. A setting of zero may be used to turn this feature off. To change the "Strikes and Out" count: 1. Press. Press (or new PAC) 1 VAC power input. Use supplied transf ormer, or 1 VDC if desired. (Input is not DC polarity sensitiv e) Auxiliary Open Feature EXIT 1 EXIT TZONE COMM Any device such as an exit button or a Knox Lock may be connected to the system to operate Relay 1 or Relay. A momentary contact closure will cause the desired Relay to latch for the programmed time. To connect an open device: 1. To activate Relay 1 connect the open device to EXIT 1 and COM.. To activate Relay connect the open device to EXIT and COM. 3. Use a two conductor, shielded cable and connect the shield to the ground screw in the Digi-Lock. 3. Press 3 4. Press (number of incorrect codes to be allowed 00 to 99) 5. Press 6. Press 0 Then BEEP! PROGRAM COMPLETE Programming Entry Code Length
7 ground screw in the Digi-Lock. Time Clock Feature A time clock may be installed and used in conjunction with the Digital Lock. This will allow certain entry codes to become valid only during designated times. The time clock must provide a dry contact closure. To install a timer or clock: The Digi-Lock may accept four or five digit entry codes. 4-Digit codes are faster to enter and program, but 5-Digit codes offer better security. The system is factory set to 4-Digit entry codes. To change the entry code length: 1. Press 1. Connect the clock relay output to TZONE and COM. (See diagram above). Designate entry codes to be valid within the time zone. (See page 6, Step 6, and Table.) 3. Time Zone designated entry codes will only be active while the dry contact is is made across the TZONE and COM input. 4. Program the time clock to activate it's dry contact for the desired time(s).. Press (or new PAC) Response BEEP! 4. Press 4 Any timer or clock must provide a dry contact closure. or 5 (Entry Code Length Desired) Failure to use a dry contact closure may cause the timer or clock to burn out the circuit board and may cause a fire. If the 5. Press timer or clock plugs directly into an AC power source and it has an AC output terminal, it does not prov ide a dry contact closure and should not be used. 6. Press 0 Then Page 4 BEEP! PROGRAM COMPLETE Page 9 3. Press 8 BEEP! INSTALLATION Programming Relay 1 Activation Time Slave Keypad Wiring Connections (Option) Relay 1 may be programmed to activate for to 40 seconds. The factory setting is 10 seconds. To program relay 1 activation time: A Slave keypad may be used with the system. All programming for the Slave keypad is done through the normal programming of the Master Keypad. Nine (9) wires are 1. Press required between the Master and Slave keypad. To install the Slave keypad:. Press (or new PAC) 1. Install the Slave keypad within 500 feet of the Master keypad.. Run a AWG, 7-conductor shielded cable and a AWG, -conductor shielded cable from the Master to the Slave keypad. 3. Press 1 3. Connect the 7-conductor cable to the Slave keypad terminals in the same order as the connection of the Master keypad. For example, connect Master 4. Press (Number of Seconds) pin 1 to Slave pin 1 etc. 4. Connect the -conductor cable from the Master 1V terminals directly to the 5. Press slave light wires. (Optional, if lighting is desired) 5. Connect cable shields to the ground screw. AWG 7-conductor 6. Press 0 Then Shielded Cable BEEP! PROGRAM COMPLETE Programming Relay Activation Time To verify the PAC:
8 1. Press. Press (or new PAC) 3. Press Master Board 1 VAC to Slave Light Bulb only Slave Board (Sold Separately) Slave Light Bulb 4. Press (Number of Seconds 00 to 40) The next five pages will explain how to program the system. If you find yourself 5. Press confused in the middle of a program step, simply remove power from the unit, wait 4 seconds, re-apply power, start your program step over. 6. Press 0 Then Notice that all programming steps begin with entering the PAC: BEEP! PROGRAM COMPLETE Or New Program Access Code (PAC) And end by exiting the programming mode: 0 Page 8 Page 5 Programming Entry Codes The factory setting for entry code length is 4-Digits. If you wish to use 5-Digit codes go to page 9 and change the length before entering codes for the first time. The Digital Lock will hold 1 to 650 entry codes depending upon the model purchased. To verify the memory size refer to the sticker on the memory chip. To enter the programming mode, a Program Access Code (PAC) must be entered. The factory set PAC is To change the PAC refer to the "Program Access Code" section on page 10. To program an entry code: Erasing Individual Entry Codes To erase a single entry code: 1. Press. Press (or new PAC) 1. Press 3. Press 6. Press (or new PAC) 4. Press (Entry Code to be deleted) 5. Press 3. Press 5 4. Press (Entry Code) 6. Press 0 Then BEEP! PROGRAM COMPLETE 5. Press "Relay Code 1-7". (See Table 1 Below) 6. Press 0 or 1 "Time Zone of/off". (See Table Below) Erasing All Entry Codes
9 CAUTION! This step will clear the entire entry code memory. 7. Press 1. Press NOTE: To add additional entry codes, repeat steps 3-7, otherwise continue.. Press (or new PAC) 8. Press 0 Then BEEP! PROGRAM COMPLETE 3. Press 7 Relay Control Codes 4. Press Relay Code Function 1 Cycle relay 1 for programmed time 5. Press Cycle relay for programmed time 3 Cycle relay 1 and for programmed time 4 Release relay 1 and 6. Press 0 Then 5 Toggle relay 1 (hold open/release relay 1) BEEP! PROGRAM COMPLETE 6 Toggle relay (hold open/release relay ) 7 Toggle relay 1 and (hold open/release relays 1&) Table 1 Time Zone 0 = Off 1 = On Page 6 Table Page 7
INSTALLATION INSTRUCTIONS FOR THE MINI-KEY SYSTEM. Doc Rev B
INSTALLATION INSTRUCTIONS FOR THE MINI-KEY SYSTEM Doc. 6001051 Rev B Page 2 of 7 Doc 6001051 Rev B IMPORTANT NOTICES The Mini-Key system is a very reliable and easy to use system. However, damage could
More informationOwner s Manual. Models 1503 and 1504 Basic Stand Alone Digital Keypad Entry Devices
Owner s Manual Models 1503 and 1504 Basic Stand Alone Digital Keypad Entry Devices DoorKing, Inc. 120 Glasgow Avenue Inglewood, California 90301 U.S.A. Phone: 310-645-0023 Fax: 310-641-1586 www.doorking.com
More informationInstallation Instructions for the AUTOcard-SA System
Installation Instructions for the AUTOcard-SA System IMPORTANT NOTICE The AUTOcard-SA system is a very reliable and easy to use system. However, damage could occur if it is installed incorrectly. In particular,
More informationINSTALLATION INSTRUCTIONS 921P EntryCheck TM
80 Avenida Acaso, Camarillo, Ca. 90 (805) 494-06 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS 9P EntryCheck TM The EntryCheck 9P Indoor/Outdoor Keypad is a surface mount
More informationDigital Keypad Introduction
K2 Digital Keypad Introduction The K02 uses the latest microprocessor technology to operate door strikes and security systems that require a momentary (timed) or latching dry contact closure. All programming
More informationEntraGuard Bronze. Quick Start Guide. Telephone Entry. 1.0 Specifications. 2.0 Unit Installation
The EntraGuard Bronze is a residential telephone keypad entry system which allows a homeowner to communicate directly with visitors and provide access by using any phone extension in the home. Because
More informationApril 2015 PRICE SCHEDULE A 2.0 Stand-Alone Access Control
Section A6 This Price Schedule is effective April 1, 2015. Date Page Comment 4-1-15 All April, 2015 Price Schedule update. 5-8-15 3 Removed model 1503. Added models 1509 / 1515 (Pg 15) to the TOC. 8-10-15
More informationSection A5. Standard Telephone Entry Systems. This Price Schedule is effective April 1, Date Page Comment
April 2015 PRICE SCHEDULE A 2.0 Section A5 This Price Schedule is effective April 1, 2015. Date Page Comment 4-1-15 All April, 2015 Price Schedule update. Prices and specifications subject to change without
More informationCarefree-Security. Installation and programming instructions 1050A. Owner s Manual
Carefree-Security Heavy Duty Commercial - Industrial Fully Sealed Digital Access Keypad Specially Designed for Gate Operators, Overhead Doors, Specialty Doors & Electric Door Locking Devices SINGLE OR
More informationINSTALLATION INSTRUCTIONS
LIGHTING CONTROL PANELS 16 AND 24 RELAYS INSTALLATION INSTRUCTIONS INSTALLATION OVERVIEW The installation instructions contained in this document are provided as a guide for proper and reliable installation.
More informationVANDAL RESISTANT BACK-LIT WEATHERPROOF ACCESS CONTROL KEYPAD
VANDAL RESISTANT BACK-LIT WEATHERPROOF ACCESS CONTROL KEYPAD Post Mount Keypad Programming & Installation Manual 1. Connect Power 12V DC to 24V AC/DC to terminals (+) and (-) Post Mount Keypad Quick Start
More informationInstallation Instructions 4291 and 4292 Keypads
Installation Instructions 4291 and 4292 Keypads A6851J 02/11 Copyright 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the
More informationINSTALLATION INSTRUCTIONS FOR THE "LP" MODEL OVATION SYSTEM. Doc Rev B
INSTALLATION INSTRUCTIONS FOR THE "LP" MODEL OVATION SYSTEM Doc. 6001073 Rev B Page 2 of 31 Doc. 6001073 Rev B IMPORTANT NOTICE Make sure you know the local telephone tariff arrangements before installing
More information6222 Two Door Module Technical Operations Manual
6222 Two Door Module Technical Operations Manual TABLE OF CONTENTS Specifications...3 Overview...4 Operations...5 Custom Access Mode...5 Standard Access Mode...5 Offline Access Mode...5 Offline Memory...5
More informationELECTRO-MECH SCOREBOARD CO.
ELECTRO-MECH SCOREBOARD CO. MODEL 2150 SHOT TIMER OWNER S HANDBOOK Thank you for choosing an Electro-Mech Scoreboard for your athletic complex. We are confident that your new shot timer will give many
More informationINSTALLATION INSTRUCTIONS 920 EntryCheck TM
801 Avenida Acaso, Camarillo, Ca. 93012 (805) 494-0622 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS 920 EntryCheck TM The EntryCheck 920 Indoor/Outdoor Keypad is a surface-mount
More informationMODEL KP-100 ACCESS CONTROL DIGITAL KEYPAD OPERATING INSTRUCTIONS
MODEL KP-100 ACCESS CONTROL DIGITAL KEYPAD OPERATING INSTRUCTIONS Model KP-100 is a self-contained digital keypad. This keypad is suitable for residential, industrial, and commercial installations. It
More informationModel 7416LED
INSTALLATION INSTRUCTIONS FOR Model 7416LED www.sportablescoreboards.com 1 Table of Contents DESCRIPTION... 3 THE SCOREBOARD SYSTEM SHOULD INCLUDE THE FOLLOWING PARTS:... 3 INSTRUCTIONS FOR REPORTING SHIPPING
More informationClick Save to return to the main Setup screen.
ON-SITE Setup Guide Thank you for purchasing the ON-SITE. This guide will assist you in the setup of the system. You can call for FREE technical support to get help anytime at 757-258-0910. Please note,
More informationJanuary 2013 PRICE SCHEDULE A 2.0. Access Plus Telephone Entry & Access Control
January 2013 PRICE SCHEDULE A 2.0 Section A4 Date Page Comment 1 1 13 All January, 2013 Price Schedule update. 2 13 13 6 Removed 1812 092 from 1812 145 kit. Added 1812 092 to 1812 147 kit. 2 13 13 9 P/N
More informationSK-3133-PPQ Heavy-Duty Outdoor Access Control Keypad with Proximity Reader
SK-3133-PPQ Heavy-Duty Outdoor Access Control Keypad with Proximity Reader Features: Rugged construction heavy-duty stainless steel faceplate with coated steel housing Built-in proximity card reader 12~24
More informationUniScan. Impro UniScan Controller INSTALLATION MANUAL
MODEL NUMBER: HCM990-0-0-GB-XX UniScan Impro UniScan Controller INSTALLATION MANUAL SPECIFICATIONS Working Environment... The Controller is designed to work in an indoor or protected outdoor environment
More informationINSTALLATION INSTRUCTIONS 920P EntryCheck TM
801 Avenida Acaso, Camarillo, Ca. 93012 (805) 494-0622 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS 920P EntryCheck TM The EntryCheck 920P Indoor/Outdoor Keypad is a surface-mount
More informationCM-110SK Standalone Keypad Installation Instructions
CM-0SK Standalone Keypad Installation Instructions. Packing List Qty Name Remarks 2 2 Keypad User manual Screwdriver Wall plugs Self-tapping screws Torx screw 0.8 x 2.4 Φ(20 mm 60 mm) 0.24 x.2 Φ (6 mm
More informationAK-21. Digital Keyless Entry System. Installation and Programming Instructions
AK-2 Digital Keyless Entry System Installation and Programming Instructions (760) 8-7000 USA & Canada (800) 2-587 & (800) 92-02 Toll Free FAX (800) 68-0 www.linearcorp.com CONTENTS COMPONENT LOCATIONS.......................................
More information703 F o u r B u t t o n D E C T I n t e r c o m
Installation & User Manual For 703 F o u r B u t t o n D E C T I n t e r c o m Wireless Intercom System Models AB, ABK, HB, HBK, Version 1.1 (2 Relay Version) P a g e 1 Contents Overview of system.pg 3
More informationFEATURES AND PROGRAMMING GUIDE SELF-CONTAINED ACCESS CONTROL SYSTEMS:
FEATURES AND PROGRAMMING GUIDE SELF-CONTAINED ACCESS CONTROL SYSTEMS: 233CARDREADER DOOR-GARD SELF-CONTAINED ACCESS CONTROL SYSTEMS offer field proven reliability and cost effective solutions for residential,
More informationSF200. Installation Guide & Quick Start Guide. 2 TFT AC Terminal Version: 1.0 Date: June 2014
SF200 Installation Guide & Quick Start Guide 2 TFT AC Terminal Version: 1.0 Date: June 2014 All design and specification declared are subject to change without notice in advance. Contents Safety Precautions
More informationDG-800 Stand-Alone Proximity Reader Instruction Manual
DG-800 Stand-Alone Proximity Reader Instruction Manual I. Features 1. Memory volume up to 1000+10 proximity cards/tokens and PINs with the programming time up to 0.5 seconds. 2. Access modes: a. Only Proximity
More information2000 Series e/em Style Keypad Installation and Programming Manual
2000 Series e/em Style Keypad Installation and Programming Manual Document Number: 6054022 Revision: 0 Date: 12/21/06 Table of Contents Table of Contents Section 1: Introduction... 6 1 Product Description...6
More informationADVANTAGE DKE QUICK START GUIDE. 2 Make sure you have everything shown here. 3. What s what? All important internal components labeled for you
1 of 6 START HERE 1 Carefully unpack box. 2 Make sure you have everything shown here. 3 Unlock and remove front panel of keypad unit, then using carriage bolts and hex nuts, attach unit to pedestal as
More informationM U L TI - SP ORT SCOREBOARD
M U L TI - SP ORT SCOREBOARD FEATURES: 24 hour clock display Count up timer with range to 9 hr. 59 min. 59 sec. Presettable countdown timer with loud beep Large 4 inch LCD digits for viewing from as far
More informationInstruction Sheet Board Style Low Water Cutoff
Instruction Sheet Board Style Low Water Cutoff 102-305 SUPERSEDES: REVISION E DATED December 12, 2007 #5401173-REV F PLANT ID 001-3902 US Patents 6,904,800, 7,243,540, and 7,317,993 Other Patents Pending
More informationQuickTouch (QT4) Owner s Manual
QuickTouch (QT4) Owner s Manual 4-Function Hand-Held Wireless Remote Control IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS Table of Contents SECTION I. APPLICATION...
More informationDoc Rev B CROWN JEWEL TELEPHONE ENTRY SYSTEM INSTALLATION INSTRUCTIONS
Doc.. 6001145 Rev B CROWN JEWEL TELEPHONE ENTRY SYSTEM INSTALLATION INSTRUCTIONS TABLE OF CONTENTS IMPORTANT NOTICES... 3 INSTALLATION TIPS... 3 PART 1 PULLING CABLES... 4 A. WIRE INFORMATION... 4 B.
More informationSecured Series: Hub Plus Kit Single Door Controller Package Installation Manual
Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual This package is designed to simplify the connections to our Secured Series Hub Plus Controller. This will translate into
More informationBack Mount SIP Access Control Intercom Installer s Guide
Back Mount SIP Access Control Intercom Installer s Guide This step-by-step guide will help you install your Wahsega Labs back mount SIP access control intercom. What s in the Box www.wahsega.com Page 2
More informationSuprex RS-485 SPX-7500 Wired Reader-Extender
Suprex RS-485 SPX-7500 Wired Reader-Extender Product Manual SPX-7500_MAN_181206 Cypress Integration Solutions 35 Years of Access Control Ingenuity CypressIntegration.com 2018 Cypress Computer Systems 1778
More informationCA-A480-A Elevator Controller. Reference & Installation Manual
CA-A480-A Elevator Controller Reference & Installation Manual TABLE OF CONTENTS INTRODUCTION.................................................................. 4 Introduction.............................................................................................
More information212iL Rev. 1.1
212iL 1 International Electronics, Inc. 427 Turnpike Street Canton, Massachusetts 02021 212iL (illuminated Luxury) Keypad Single Unit Keypad- Control Installation Manual Features: 120 User Capability Illuminated
More informationACTsmart2 Product Range Operating and Installation Instructions
ACTsmart2 Product Range Operating and Installation Instructions 18-00045 Contents ORDERING INFORMATION......4 INSTALLATION NOTES......5 IMPORTANT......5 PRODUCT SPECIFICATION......5 30 SECOND PROGRAMMING
More informationCV-110SPK Standalone Keypad/Prox Access Control Installation Instructions
CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions 1. Packing List Qty Name Remarks 1 1 1 2 2 1 Keypad User manual Screwdriver Wall plugs Self-tapping screws Torx screw 0.8 x 2.4
More informationPAC1 Door Access Controller
PAC1 Door Access Controller Series 1 TABLE OF CONTENTS i PAGE Introduction...1 Features...1 Specifications...2 Terminal Descriptions...3 Programmable Features Description...5 Automatic Relock Function...5
More informationEL-ST100 KEYPAD CONTROLLER
WIRING DIAGRAM EL-ST100 KEYPAD CONTROLLER WEATHER-PROOF STANDALONE ACCESS CONTROLLER WITH KEYPAD & PROXIMITY TECHNOLOGY Programming and Installation Manual NOTE: www.elock2u.com ICT at work! Version 3.6
More informationPAC1 Door Access Controller
PAC1 Door Access Controller Series 1 100% Designed and Manufactured by: NIDAC SECURITY PTY. LTD. 2 CROMWELL STREET BURWOOD, VICTORIA Tel: (03) 9808 6244 AUSTRALIA 3125 Fax: (03) 9808 9335 Revision 1.1
More informationPAC2 Dual Door Access Controller
PAC2 Dual Door Access Controller Series 2 IMPORTANT DIFFERENCES FROM SERIES 1 1. All programming can only be done through devices attached to DTA1. 2. A PACDL data logger revision 4.0 or higher attached
More informationMODEL 3312 LED
INSTALLATION INSTRUCTIONS FOR MODEL 3312 LED www.sportablescoreboards.com 1 Table of Contents DISCRIPTION... 3 THE SCOREBOARD SYSTEM SHOULD INCLUDE THE FOLLOWING PARTS:... 3 INSTRUCTIONS FOR REPORTING
More informationINSTALLATION INSTRUCTIONS Model 930 EntryCheck
SECURITY DOOR CONTROLS 3580 Willow Lane, Westlake Village, CA 91361-4921 (805) 494-0622 Fax: (805) 494-8861 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS Model 930 EntryCheck
More informationCV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions
CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions Packing List NAME MODEL/SIZE QTY Self tapping screw 0.15 x 1.06 (4mm 27 mm) Rubber plug 0.23 x 1.2 (6mm 30 mm) Star screw driver
More information232iLM Keypad Installation and Programming Instructions
232iLM Keypad Installation and Programming Instructions Note: This product is designed to be installed and serviced by security and lock industry professionals. Specifications Case Dimensions: 6 1 / 2
More informationSmartLock Controller INSTALLATION MANUAL
SmartLock Controller INSTALLATI MANUAL November 2015 Table of Contents INTRODUCTI... 3 Diodes... 4 Terminal Strips and Cable... 5 SPECIFICATIS... 6 SMARTLOCK CTROLLER LAYOUT... 8 LED Indicators... 9 Mounting...
More informationIndoor/Outdoor Proximity Reader and Keypad with 10cm (4in) Read Range
Indoor/Outdoor Proximity Reader and Keypad with 10cm (4in) Read Range Stand alone CR-R885-SB Installation and Operating Instructions V1.1 TABLE OF CONTENTS Installation... 2 Mounting and Wiring... 2 Mounting
More information1 IF-810 or IF-811 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-810/IF-811
95-10326_V2016-10-20 IF-810/IF-811 1 IF-810 or IF-811 Terminal (Slave) Thank you for choosing an Interflex system. With an IF-810 or IF-811 terminal (slave), you have purchased a reliable device for capturing
More informationGUARD CENTURION OPERATING INSTRUCTIONS THE AUTOMATIC CHOICE
GUARD CENTURION THE AUTOMATIC CHOICE OPERATING INSTRUCTIONS 0 In a In hurry? a hurry? The following KwikLearn procedure and connection diagram will enable you to start using your SmartGUARD system right
More informationAMERICAN ACCESS SYSTEMS, INC. DKS II. with Advantage RCG Technology INSTALLATION & PROGRAMMING INSTRUCTIONS
AMERICAN ACCESS SYSTEMS, INC. DKS II with Advantage RCG Technology INSTALLATION & PROGRAMMING INSTRUCTIONS MODELS: 24-100, 24-500, 24-1000, 24-2000 AAS 2-Year Limited Warranty What item(s) this warranty
More informationAMERICAN ACCESS SYSTEMS, INC.
AMERICAN ACCESS SYSTEMS, INC. American Access Systems, Inc. 7079 South Jordan Road #6 Centennial, CO 80112 TECH: (303) 799-9757 SALES: 800-541-5677 FAX: (303) 799-9756 PROX 2000 II INSTALLATION & PROGRAMMING
More information603 D E C T I n t e r c o m
Installation & User Manual For 603 D E C T I n t e r c o m Wireless Intercom System Models AB, ABK, HB, HBK, FB, FBK Version 3 P a g e 1 Contents Overview of system.pg 3 Site Survey.Pg 3 Mounting the Transmitter.Pg
More informationINSTALLATION INSTRUCTIONS FOR
INSTALLATION INSTRUCTIONS FOR MODEL 3314 LED www.sportablescoreboards.com 1 Table of Contents DESCRIPTION... 3 THE SCOREBOARD SYSTEM SHOULD INCLUDE THE FOLLOWING PARTS:... 3 INSTRUCTIONS FOR REPORTING
More informationUser Manual. PCKeypad Wireless Keypad
User Manual PCKeypad Wireless Keypad Description The PCKeypad is a wireless keypad with a PentaCODE transmitter built-in. It works with all of Elsema s PCR series receivers. The installer has the option
More informationQuick Draw Electronics. Shooting Sports Timer User Manual. Model AIO-1
Quick Draw Electronics Shooting Sports Timer User Manual Model AIO-1 Rev. C October 2017 QUICKDRAW ELECTRONICS SHOOTING SPORT TIMER SYSTEM THE SYSTEM CONSISTS OF; 1 IMPACT SENSOR 1 LIGHT ASSEMBLY 1 ALL
More informationicp installation guide
The Information Control Point (icp) is the latest SmartFarm Technology by Inc. The icp is the ultimate on-farm data-management tool. The icp has all the power of a basic personal computer, but instead
More informationOwner s Manual. Model 1812 Telephone Intercom Systems
Owner s Manual Model 1812 Telephone Intercom Systems DoorKing, Inc. 120 Glasgow Avenue Inglewood, California 90301 U.S.A. Phone: 310-645-0023 Fax: 310-641-1586 www.doorking.com P/N 1812-065 REV M, 3/07
More informationEPD. Installation/Owner s Manual. Model 1802 & 1802EPD Telephone Entry System. Surface Mount Flush Mount. UL Listed
Installation/Owner s Manual Use this manual for circuit board 86- Revision L or higher. Model 8 & 8EPD Telephone Entry System 8-65-D--4 Control a main entry point plus an additional entry point. 8. 3 ATING
More informationInstallation OVERVIEW
Installation OVERVIEW The DEMCO GATE ACCESS CONTROL SYSTEM is designed to operate up to 4 gates, each with an IN KEYPAD and/or an OUT KEYPAD. Each gate is wired as illustrated in the drawing of a "TYPICAL
More information1 IF-812 or IF-815 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-812/IF-815
95-10324_V2016-11-23 IF-812/IF-815 1 IF-812 or IF-815 Terminal (Slave) Thank you for choosing an Interflex system. With an IF-812 or IF-815 terminal (slave), you have purchased a reliable device for capturing
More informationPARTNER Contact Closure Adjunct
Closure Installation Instructions BEFORE STARTING INSTALLATION, READ AND UNDERSTAND ALL SAFETY INSTRUCTIONS ON PAGE. The is used with a Advanced Communications System processor module (available separately)
More informationTwo Door Controller GEN-045
Australian Owned, Designed and Manufactured Two Door Controller GEN-045 Genesis Electronics Australia Pty Ltd www.genesiselectronics.com.au Distributed by: Genesis reserves the right to change or modify
More informationAS Keypad User Manual
AS Keypad User Manual Specifications Operating Voltage: 12~24 VAC/DC Current Draw: TBA Input: request-to-exit (for Relay 1) time out reed switch contact (for Relay 1) Output: Relay 1: N.O./N.C./Com. Output
More informationMAXIMA + Series ROTARY LEVEL CONTROL
Price $5.00 MAXIMA + Series ROTARY LEVEL CONTROL OPERATING INSTRUCTIONS PLEASE READ CAREFULLY Division of Garner Industries 7201 North 98th Street Lincoln, NE 68507-9741 (402) 434-9102 925-0268 TABLE OF
More informationInstallation Notes TII Model 341 Protector
Installation Notes TII Model 341 Protector (ATT-IS PEC 32918) for MERLIN Communications System In Range Out of Building (IROB) Station Installation By Trained Technician Only WARNING: Failure to follow
More informationWiring Inside the card reader you will see a circuit board. The connections are as follows:
Power Adaptor (12VDC, Max. Current: 1A) If you purchased the Cardlock Series power supply cut the head of the adaptor and strip the insulation. If your locking mechanism, electric strike or magnetic lock
More informationPXL-250 Tiger Controller
PXL-0 Tiger Controller This quick start guide is made up of specification sheets, a DO/DON T list, basic installation drawings, first time power-on instructions, and short descriptions of key terms and
More informationOwner s Manual PC Programmable Multi-Door Access Controller
Owner s Manual PC Programmable Multi-Door Access Controller DoorKing, Inc. 0 Glasgow Avenue Inglewood, California 00 U.S.A. Phone: 0--00 Fax: 0-- www.doorking.com P/N -0 REV W, 0/ Copyright 00 DoorKing,
More informationE-Access ANXELL TECHNOLOGY CORPORATION E3AK4 E3AK2. Specifications Voltage (Input): 12 to 24 VDC
E-Access E3AK1 E3AK2 E3AK3 E3AK4 4-3/4" x 2-15/16" x 1-13/16" (120 x 74 x 46.2 mm ) 4-1/2" x2-3/4" x1-5/8" (114 x 70 x 41 mm) 4-13/16" x 3" x 2-1/2" (123 x 77 x 64.2 mm) 3-7/16" x 3-7/16" x 1-3/4" (87.3
More informationSK-1011-SDQ Access Control Keypad. Manual
SK-1011-SDQ Access Control Keypad Manual Quick Installation Guide: This page is for installers looking to do a basic installation and programming of the keypad. For more in-depth installation and programming
More informationgenesis TECHNICAL MANUAL Two-Door Controller GEN-045
Two-Door Controller GEN-045 Genesis Electronics Australia Pty Ltd www.genesiselectronics.com.au info@genesiselectronics.com.au Australian Owned, Designed and Manufactured Distributed By:- Genesis reserves
More informationCopy Machine Reader. Installation and Setup Guide
Copy Machine Reader Installation and Setup Guide CONTENTS 1 COPY MACHINE READER INSTALLATION 1 Overview 1 Reader Specifications 3 CR1120/CR1122 INSTALLATION 3 Copier Interface 3 AC Electrical 3 Communications
More informationInstallation/Owner s Manual
Installation/Owner s Manual Model 1812 Classic Residential Telephone Intercom/Access Control System Use this manual for circuit board 1871-1 Revision S or higher. 1812-65-U-12-13 Control a main door and
More informationSeries 803 LED Product Price Display
Series 803 LED Product Price Display May 2007 Rev. 1.1 1 Installation and Operation Manual Table of contents 1. Safety.......3 2. Series 803 sign features.......4 2.1 Sign descriptions........4 2.2 Control
More informationAMERICAN ACCESS SYSTEMS, INC.
AMERICAN ACCESS SYSTEMS, INC. PROX 2000 II INSTALLATION & PROGRAMMING INSTRUCTIONS MODELS: 23-206 AAS 2-Year Limited Warranty What item(s) this warranty applies to: American Access Systems "PROX 2000 II
More informationInstallation/Owner s Manual
Installation/Owner s Manual Model 1812 Classic Residential Telephone Intercom/Access Control System Use this manual for circuit board 1871-1 Revision S or higher. 1812-65-B-1-17 Control a main door and
More informationInstallation Instructions
Alliance Arming Station AL-1111, AL-1116 1048520C September 2006 Copyright 2006, GE Security Inc. Introduction This is the GE Alliance Arming Station for models AL-1111 (four-line LCD) and AL-1116 (four-line
More information232iLM Keypad Installation & Programming Instructions
232iLM Keypad Installation & Programming Instructions Note: This product is designed to be installed and serviced by security and lock industry professionals. Specifications Case Dimensions: 6-1/2 L x
More informationKP2000E/EM Series Style Keypad
23852973 KP2000E/EM Series Style Keypad Installation and Programming Instructions Models KP2000EXX and KP2000EMXX Specifications Parameter Voltage Requirements Keypad Current Requirements (Max) Relay Contact
More informationEVERSAN. Instruction Manual MODEL 9007/9008 TENNIS SCOREBOARD. Address: 34 Main Street, Whitesboro, NY 13492
MODEL 9007/9008 TENNIS SCOREBOARD Instruction Manual Address: 34 Main Street, Whitesboro, NY 13492 Phone: 315-736-3967 Toll Free: 800-383-6060 Fax: 315-736-4058 SCOREBOARDS TIMERS MESSAGE SIGNS VIDEO DISPLAYS
More informationSuprex Fiber Optic. Reader-Extender SPX-7400 SPX Product Manual. Reader-Extender. Manual. SPX-7400 Series EXP Suprex_FiberOptic_MAN_170502
Suprex Fiber Optic Reader-Extender SPX-7400 SPX-7410 Product Manual Reader-Extender Manual SPX-7400 Series EXP-2000 Suprex_FiberOptic_MAN_170502 Cypress Integration Solutions 30+ Years of Access Control
More informationQuick Draw Electronics. Shooting Sports Timer User Manual. Model CLUB All In One
Quick Draw Electronics Shooting Sports Timer User Manual Model CLUB All In One Rev. C August 2018 QUICKDRAW ELECTRONICS SHOOTING SPORT TIMER SYSTEM THE SYSTEM CONSISTS OF; IMPACT SENSOR LIGHT ASSEMBLY
More informationOwner s Manual. 1833, 1834, 1835, 1837 PC Programmable Telephone Entry and Access Control Systems
Owner s Manual 1833, 1834, 1835, 1837 PC Programmable Telephone Entry and Access Control Systems DoorKing, Inc. 120 Glasgow Avenue Inglewood, California 90301 U.S.A. Phone: 310-45-0023 Fax: 310-41-158
More informationOwner s Manual PC Programmable Multi-Door Access Controller
Owner s Manual PC Programmable Multi-Door Access Controller DoorKing, Inc. 0 Glasgow Avenue Inglewood, California 00 U.S.A. Phone: 0--00 Fax: 0-- www.doorking.com P/N -0 REV P, / Copyright 00 DoorKing,
More informationTable of Contents. General Information. Document Sure-Aire Flow Monitoring System. User and Service Manual WARNING CAUTION
Document 476092 User and Service Manual Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install,
More informationBasketball Shot Clock Set LX2180 Manual
Basketball Shot Clock Set LX2180 Manual 72 Industrial Boulevard Wrightsville, GA 31096 Phone: (800) 445-7843 Fax: (800) 864-0212 www.electro-mech.com LX2180 Revision 5 February 8, 2013 Table of Contents
More informationVOICE and/or DATA CELLULAR SYSTEM
... VOICE and/or DATA CELLULAR SYSTEM The Voice/Data or Data Only Cellular System operates on DoorKing s cellular network that is hosted on the AT&T G LTE network where available. The system provides voice
More informationWiring Guide EP.NMINI. Version 1.02 Last Updated:
Wiring Guide EP.NMINI Version 1.02 Last Updated: 14-10-2014 1 Note: See http://www.entrypass.net/ for updates, revisions, and download the latest installation manual There are currently 2 version of EntryPass
More informationELECTRO-MECH SCOREBOARD CO.
ELECTRO-MECH SCOREBOARD CO. MODEL 2570 BASKETBALL SCOREBOARD OWNER S HANDBOOK Thank you for choosing an Electro-Mech Scoreboard for your athletic complex. We are confident that your new scoreboard will
More informationSECURITY DOOR CONTROLS 801 Avenida Acaso, Camarillo, Ca (805) Fax: (805)
SECURITY DOOR CONTROLS 801 Avenida Acaso, Camarillo, Ca. 93012 (805) 494-0622 Fax: (805) 494-8861 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS Model 931 EntryCheck The
More informationCP150B Vandal & Weather Resistant Keypad Security Systems
Vandal & Weather Resistant Keypad Security Systems EN Security System CP150B - Vandal & Weather Resistant Keypad The CP150B keypad provides alarm and or access control functionality when used on selected
More informationVOICE and/or DATA CELLULAR SYSTEM
... VOICE and/or DATA CELLULAR SYSTEM This cellular device cannot be used for 9 calls. The Voice/Data or Data Only Cellular System operates on DoorKing s cellular network that is hosted on the AT&T G LTE
More informationOverview These instructions are presented as a guideline for installing and setting up the LX Series Breaker Control Panel.
LX Breaker Control Panels Installation and Setup Procedure Hubbell Building Automation, Inc. 9601 Dessau Road Building One Suite 100 Austin, Texas 78754 512-450-1100 512-450-1215 Fax www.hubbell-automation.com
More informationOutdoor Stand-Alone Weatherproof Keypads
Outdo Stand-Alone Weatherproof Keypads Manual (SK-2323-SDQ shown) (SK-1323-SPQ shown) Model Number 2 Relay Outputs Mullion-Style Keypads Backlit Keys Proximity Reader SK-2323-SDQ SK-2323-SPQ Sealed-Environment
More informationMAXIMA + Series ROTARY LEVEL CONTROL
Price $5.00 MAXIMA + Series ROTARY LEVEL CONTROL OPERATING INSTRUCTIONS PLEASE READ CAREFULLY Division of Garner Industries 7201 North 98th Street Lincoln, NE 68507-9741 (402) 434-9102 925-0268 Rev. A
More information