1 Enclosure Power Distribution Units (PDUs) (continued) PDU Selection: Basic, with ocal Monitoring and Intelligent Highly secure access with admin, control and view-only accounts Intuitive Ethernet-based firmware with alarm or SNMP trap features prevents downtime with early notification of power threshold breaches SNMP (MIB) enabled for compatibility with all leading DCiM packages Integrated environmental monitoring capabilities; monitor temperature, air flow, humidity and dew point via optional connected sensors Internal memory for up to two week of trending of critical parameters for clear understanding of power allocation and usage PDU mounted display option for local current or power monitoring, making phase balancing easier (the PDU itself is not phase balancing) Intelligent PDU Options and Features Remote aggregate, circuit or receptacle power monitoring for granular PUE measurement Switched (on/off) options allow remote outlet management and equipment reboot with sequential delay features; avoid power interruption due to inrush current, equipment start up in desired sequence PDU Firmware, Trending Page Intelligent-Remote Monitoring () Belden PDU ocal Display/ Monitoring Current Basic (B) ocal () Current (C) Power (P) Power (O) Switched (S) () (2) (2) (2) Power Circuit Environmental evel Port (4) Power evel (5) Switched (6) Optional PDU Firmware, Alarm Setting Page tes: () ocal current/amp meter, monitoring at circuit level for multi-circuit PDU. (4) Remote IP-based environmental monitoring, (2) port per PDU. Requires external sensor, refer to accessories (p. 78) for selection. (2) ocal power meter provides Amps, Volts, Watts, Volt-Amps, kwh and Power Factor. (5) Remote IP-based receptacle level monitoring, Amps, Volts, Watts, kwh. () Remote functions (IP-based) accessible via web browser. (6) Remote IP-based receptacle level switching (on/off) with configurable time delay. Intelligent PDU Communication and Environmental Monitoring Ports Power, Cooling and Air Handling Relations Branch Circuit Rating (A) Nameplate Volts (V) Volts Actual Delivered (V) Phase* PDU minal PDU De-Rated Power Watts (W) Power (W) PDU De-Rated Power (kw) PDU De-Rated Power (BTU/hr.) AC Tons** (BTU/00) Air Volume*** ( CFM* kw) , ,400, , ,9.9 6, ,0 2, , ,,28., ,0 4, , ,400 7,280 7., ,480 9, , , ,0, , ,900 5, , ,800, ,69.4, 6 /8 8 7,97 5, , /8 8 0,795 8,66 29, , /8 8 7,992 2, , ,72 48 /8 8 2,66 7, , , /8 8 6,027 28, , , /8 8 45,0 6, , , 50 /8 8 54,040 4, , ,84 6 2/400 2,856, ,69.4, 2/400 2,785 6, ,56 4.7,992 PDU Nameplate Current Rating (A) *-Phase power is calculated by multiplying single phase by the square root of or.7. **Tons of air conditioning required to remove heat from associated IT load. ***The volume of air that is typically required by the IT equipment for each kw of IT load can typically range from 80 to 40 CFM. CFM was used for calculation..800.beden. ( ) 7

2 Single-Phase PDUs Front View 9F-000 Rear View 9F-000 U isted Single-Phase PDUs : B = Basic; = ocal Monitored 9B2-00 De-Rated Amps (A)/ Power (kw) Volts (V) Thermal /Qty Circuit Breaker On-Off Switch Surge Monitoring- Supression ocal Mounting (4) x W x D (in.) 9BF-00 B.4 5/ 5-5P 6 5-5R/6 Rack - 9" 7 x.72 x.75 9BF-002 B.4 5/ 5-5P 6 5-5R/6 Rack - 9" 7 x.72 x.75 9BF-0800 B.4 5/ 5-5P 8 5-5R/8 x.6 x.6 9F / 5-5P 0 5-5R/0 Power Rack - 9" 7 x.72 x 4.5 9BF-400 B.4 5/ 5-5P 4 5-5R/ x.6 x.6 9BG B.9 / 5-P 8 5-R/8 x.6 x.6 9BG-000 B.9 / 5-P 0 5-R/0 Rack - 9" 7 x.72 x.75 9G-000 B.9 / 5-P 0 5-R/0 Power Rack - 9" 7 x.72 x 4.5 9BG-400 B.9 / 5-P 4 5-R/ x.6 x.6 9BG2-400 B.9 / 5-P 4 5-R/ x.6. x.6 9BG-4002 B.9 / 5-P 4 5-R/ x.6. x.6 9BG B.9 / 5-P 4 5-R/ x.6. x.6 9H / 5-P 5-R/ Magnetic Breaker Power 9B /8 6-P 2 C-/2 Magnetic Breaker Power Rack - 9" 7 x.72 x 6.5 9B /8 6-P C-/ + C-9/6 Magnetic Breaker Power tes: () Standard cord length is 0 ft. For other lengths, change dd digit in part # (ex: 9PB2-dd0 would be 9PB2-080 = 8 ft). Available in 2, 4, 6, 8, 0, 5, ft. (2) Standard cord exits from chassis face; top of chassis exit () Standard PDU chassis color is black, custom color overlay Front View 9PG2-000 Rear View 9PG2-000 U isted Single-Phase PDUs : P = Remote Power Monitored; O = Monitored tes: De-Rated Amps (A)/ Power (kw) Volts (V) () Standard cord length is 0 ft. For other lengths, change dd digit in part # (ex: 9PB2-dd0 would be 9PB2-080 = 8 ft). Available in 2, 4, 6, 8, 0, 5, ft. /Qty 9OB2-00 Thermal Circuit Breaker (2) Standard cord exits from chassis face; top of chassis exit () C-, refers to receptacles with locking feature. On-Off Switch Monitoring-ocal/ Remote Environmental Monitoring (4) Standard PDU chassis color is black, custom color overlay (5) These PDUs have no Surge Supression. Mounting (4) x W x D (in.) 9PG2-000 P.9 / 5-P 0 5-R/0 + 0 Magnetic Power/Aggregate - 2 Port Rack - 9" 7 x.72 x 6.5 9PB2-00 P 5 /8 6-P C-/ + C-9/6 Magnetic Breaker Power/Circuit Breaker - 2 Port.25 9PB2-002 P 5 /8 6-P C-/ + C-9/6 Magnetic Breaker Power/Circuit Breaker - 2 Port 72 x 2 x PB P 5 /8 6-P 42 C-/6 + C-9/6 Magnetic Breaker Power/Circuit Breaker - 2 Port 70 x 2 x OB2-00 O 5 /8 6-P C-/8 + C-9/6 Magnetic Breaker Power/Circuit Breaker Port 72 x 2.25 x BEDEN. ( )

3 -Phase PDUs 9I2-00 ZPB8-06IBBPS5 U isted -Phase PDUs : B = Basic; = ocal Monitored De-Rated Amps (A) Power (kw) x Phases Input Volts (V)/ Output Volts (V) /Qty(s) Circuit Breaker MonitoringMounting (Amp/Qty) ocal/remote x W x D (in.) 9I x Ph. /8 WYE/8 2-P C-/ + C-9/6 Amp (X,Y,Z)/ Dog House - 9J2-00 x Ph. /8 WYE/8 2-P C-/ + C-9/6 /D Amp (X,Y,Z)/ Dog House - 9BJ2-00 B x Ph. /8 WYE/ & 8 2-P C-/ + C-9/ + 5-R/6 /D Amp (X,Y,Z)/ Dog House - 9C2-00 x Ph. 2/400 WYE/2 22-P C-/ + C-9/6 Amp (X,Y,Z)/ Dog House - 9C-00 x Ph. 2/400 WYE/2 C-/ + C-9/6 Amp (X,Y,Z)/ Dog House - 9D x Ph. 2/400 WYE/2 22-P C-/ + C-9/6 /D Amp (X,Y,Z)/ Dog House - 9D x Ph. 2/400 WYE/2 C-/ + C-9/6 /D Amp (X,Y,Z)/ Dog House - 9B-200 B 7. x Ph. 8 Delta/8 2 C-9/2 + 0 /6 Breaker/ Rack - 9" 7 x.4 x 9 Dog House - 9B-00 B 7. x Ph. 8 Delta/8 C-/2 + C-9/2 /6 Breaker/ x 2. x.45 Dog House - tes: () Standard cord length is 0 ft. For other lengths, change dd digit in part # (ex: 9PB2-dd0 would be 9PB2-080 = 8 ft). Available in 2, 4, 6, 8, 0, 5, ft. (2) Standard cord exits from chassis face; top of chassis exit () C-, refers to receptacles with locking feature. (4) Ex: /D, D refers to double pole breakers (A in this case). (5) Standard PDU chassis color is black, custom color overlay (6) These PDUs have no Surge Supression or On/Off Switch. (7) PDU Dog House hosts the circuit breaker and protrude from the PDU chassis by.44". 9PC OJ2-00 U isted -Phase PDUs De-Rated Amps (A) Power (kw) x Phases Input Volts (V)/ Output Volts (V) /Qty(s) x Ph. /8 WYE/8 2-P 44 C-/6 + C-9/6 + 5-R/2 Power/X, Y, Z - 2 Port 70 x 2 x 2.25 Dog House - x Ph. /8 WYE/8 2-P C-/ + C-9/6 /D Current/Current Dog House - O x Ph. /8 WYE/8 2-P C-/ + C-9/6 /D Power/X, Y, Z + 72 x 2.25 x Port Dog House - 9OC2-00 O x Ph. 2/400 WYE/2 22-P C-/8 + C-9/6 Power/X, Y, Z Port Dog House - 9OD-00 O 6.6 x Ph. 2/400 WYE/2 C-/8 + C-9/6 /6 Power/X, Y, Z + 72 x 2.25 x Port Dog House - 9P-00 P 7. x Ph. 8 Delta/8 4P, 4W C-/ + C-9/6 /6D 9PC P 5.8 9CJ2-00 C 9OJ2-00 tes: () Standard cord length is 0 ft. For other lengths, change dd digit in part # (ex: 9PB2-dd0 would be 9PB2-080 = 8 ft). Available in 2, 4, 6, 8, 0, 5, ft. (2) Standard cord exits from chassis face; top of chassis exit () C-, refers to receptacles with locking feature. (4) Ex: /D, D refers to double pole breakers (A in this case). (5) Standard PDU chassis color is black, custom color overlay.800.beden. ( ) Circuit Breaker MonitoringEnviron. (Amp/Qty) (4) ocal/remote Monitoring Power/X, Y, Z - 2 Port x W x D (in.) 72 x 2. x.45 Dog House - (6) These PDUs have no Surge Supression or On/Off Switch. (7) PDU Dog House hosts the circuit breaker and protrude from the PDU chassis by.44". (8) All these -Phase PDUs are vertically mounted. 75 : C = Remote Current Monitored; P = Power Monitored; O = Monitored

4 Single- and -Phase PDUs Front View 9SG Rear View 9SG U isted Single- and -Phase PDUs : S = Remotely Switched 9SJ2-00 9SJ2-002 De-Rated Amps (A) Power (kw) x Phases Input Volts (V)/ Output Volts (V) / Circuit Breaker Qty(s) (Amp/Qty) (4) Monitoring-ocal/ Remote Mounting (5) 9SG-0800 S.9 / 5-P 8 5-R/8 Power/Agg Power Rack - 9" 9SG S.9 or. or 8/ or 8 C- 8 C-/8 Power/Agg + Rack - 9" 9SB2-00 S 5 8/8 6-P 9SJ2-00 S x Ph. /8 WYE/8 2-P 9SJ2-002 S x Ph. /8 WYE/8 2-P 9SC-00 S x Ph. 2/400 WYE/2 9SC-002 S x Ph. 2/400 WYE/2 9SC2-00 S x Ph. 2/400 WYE/2 22-P 9SC2-002 S x Ph. 2/400 WYE/2 22-P 9SD-00 S 6.6 x Ph. 2/400 WYE/2 9SD-002 S 6.6 x Ph. 2/400 WYE/2 9SD2-00 S 6.6 x Ph. 2/400 WYE/2 22-P 9SD2-002 S 6.6 x Ph. 2/400 WYE/2 22-P 9S-00 S 7.2 x Ph. 8 Delta/8 9S-002 S 7.2 x Ph. 8 Delta/8 C-/ + C-9/4 C-/8 + C-9/6 C-/8 + C-9/6 C-/2 + C-9/ C-/2 + C-9/ C-/2 + C-9/ C-/2 + C-9/ C-/2 + C-9/ C-/2 + C-9/ C-/2 + C-9/ C-/2 + C-9/ C-/8 + C-9/6 C-/8 + C-9/6 /2D Power/Agg, Circuit, /D Power/Agg, Circuit /D Power/Agg, Circuit, Power/Agg, Circuit Power/Agg, Circuit, Power/Agg, Circuit Power/Agg, Circuit, /6 Power/Agg, Circuit /6 Power/Agg, Circuit, /6 Power/Agg, Circuit /6 Power/Agg, Circuit, /6D Power/Agg, Circuit /6D Power/Agg, Circuit, x W x D (in.) 7 x.72 x 8.5 Dog House - 7 x.72 x 8.5 Dog House - 70 x 2.5 x 2.25 Dog House - 70 x 2.5 x 2.25 Dog House - 70 x 2.5 x 2.25 Dog House - Dog House - Dog House - Dog House - Dog House - Dog House - Dog House - Dog House - Dog House x 4 x.45 Dog House x 4 x.45 Dog House - tes: () Standard cord length is 0 ft. For other lengths, change dd digit in part # (ex: 9PB2-dd0 would be 9PB2-080 = 8 ft). Available in 2, 4, 6, 8, 0, 5, ft. 9SG Power Cord is sold separately. (2) Standard cord exits from chassis face; top of chassis exit () C-, refers to receptacles with locking feature. (4) Ex: /D, D refers to double pole breakers (A in this case). (5) Standard PDU chassis color is black, custom color overlay (6) These PDUs have no On/Off Switch or Surge Supression. (7) PDU Dog House hosts the circuit breaker and protrude from the PDU chassis by.44". (8) All these Single- and -Phase PDUs have a Switched and a 2-port Environmental Monitor BEDEN. ( )

5 PDU Accessories Mounting, Cord Management and Cord Set Description Belden Part Number Tool-ess PDU Mounting Panel (for XM and XS Style Enclosures) XVMP04 XVMP0450 XVMP0480 XVMP0 XVMP050 XVMP080 XVMP042 XVMP04502 XVMP04802 XVMP02 XVMP0502 XVMP0802 acing-pdu Mounting Panel,.5"W, 42RU, Black acing-pdu Mounting Panel,.5"W, 45RU, Black acing-pdu Mounting Panel,.5"W, 48RU, Black acing-pdu Mounting Panel, 7"W, 42RU, Black acing-pdu Mounting Panel, 7"W, 45RU, Black acing-pdu Mounting Panel, 7"W, 48RU, Black acing-pdu Mounting Panel,.5"W, 42RU, White acing-pdu Mounting Panel,.5"W, 45RU, White acing-pdu Mounting Panel,.5"W, 48RU, White acing-pdu Mounting Panel, 7"W, 42RU, White acing-pdu Mounting Panel, 7"W, 45RU, White acing-pdu Mounting Panel, 7"W, 48RU, White 7" acing-pdu mounting panel.5" acing-pdu mounting panel Tool-ess PDU Mounting Panel (for XN Style Enclosures) PDU Mounting Bracket Double, Post Mounting 2 PDU Side-by-Side Facing Into Enclosure PDU Mounting Bracket Single, Rear Facing Pair PDU Mounting Bracket Rear Facing Pair Between Frames PDU Mounting Bracket Rear Facing Pair Between Frames with Extension Manager Panel, 42RU X 7.0"W, Black Manager Panel, 45RU X 7.0"W, Black Manager Panel, 48RU X 7.0"W, Black Manager Panel, 42RU X 7.0"W, CO White Manager Panel, 45RU X 7.0"W, CO White Manager Panel, 48RU X 7.0"W, CO White Tool-ess PDU Mounting Panel (for XSS Seismic Enclosures) XNPM0 XNPM02 XNPM0 XNPM04 XNVP4290 XNVP4590 XNVP4890 XNVP42902 XNVP45902 XNVP48902 Mounting Brackets Cable PDU Manager Rear Panel, 44RU, Rear, Black Cable PDU Manager Rear Panel, 44RU, Rear, with 6 Rings, Black Cable PDU Manager Rear Panel, 44RU, Rear, CO White Cable PDU Manager Rear Panel, 44RU, Rear, with 6 Rings, CO White Tool-ess PDU Mounting Panel (for XSN Seismic Enclosures) XSN44VRPM0 XSN44VRPM XSN44VRPM02 XSN44VRPM2 Cable PDU Manager Rear Panel, 44RU, Rear, Black Cable PDU Manager Rear Panel, 44RU, Rear, with 6 Rings, Black Cable PDU Manager Rear Panel, 44RU, Rear, CO White Cable PDU Manager Rear Panel, 44RU, Rear, with 6 Rings, CO White Power Cord Management XSN44VRPM0 XSN44VRPM XSN44VRPM02 XSN44VRPM2 Quick Mount Base XMR0 XMR0 XSK0 XCTM AX0078 AX00784 Cord Set* (C/C9, C9/C - U - cu isted) C to C4 n-ocking Cord Set - Y" ong Black C to C4 n-ocking - 6" ong Black C to C4 n-ocking - 48" ong Black C9 to C n-ocking Cord Set - Y" ong Black C9 to C n-ocking - 6" ong Black C9 to C n-ocking - 48" ong Black C ocking to C4 - " ong Blue C ocking to C4 - " ong Orange C9 ocking to C - " ong Blue C9 ocking to C - " ong Orange C ocking to C4-9" ong Blue C ocking to C4-9" ong Orange C9 ocking to C - 9" ong Blue C9 ocking to C - 9" ong Orange CSCC4yyBK CSCC46BK CSCC448BK CSC9CyyBK CSC9C6BK CSC9C48BK CSCC4B CSCC4OR CSC9CB CSC9COR CSCC49B CSCC49OR CSC9C9B CSC9C9OR ocking Cord Set* *Built within the plug housing on the female end (C/C9) of the cord, the patented integrated locking mechanism is protected against vibration and external elements that can easily dislodge other plug securing solutions, like external locking clips and guides. This self-contained locking mechanism engages with any standard IEC male connector (C4/C). The cord locking feature is only available at the device-end of the cord sets. A power strip with locking receptacles must be available to secure these cords to the PDU. tes: yy = 2,, = cord length 2 to 96 inches; 2 inch increments..800.beden. ( ) 77 Cable Management Ring Plastic (Qty = 5) " x.5" Reversible Cable Management Ring Kit (Qty = 5) 2.5"W x "D Slack Management Spool Kit (includes 2 spools) Quick Mount Base (Qty=0) with Fastener, for /4" Holes Velcro Cable Ties, 25 per Roll, 8" x 0.5"W Velcro Cable Ties, 25 per Roll, 2" x 0.5"W Cable Management Ring (Plastic)

6 Power Distribution Unit Configuration Guide Please select the desired configuration and specifications and submit to Belden. Power Availability Quantity Required First Unit Required by Date Electrical Configuration Power Input Quantity** Input S Input 5-5P P P 25 5-P 25 6-P 6-P 4-P 25/ 2-P x ~ /8 WYE 5-P 25 6-P 4-P 25/ 5-P x ~ Delta 2-P x ~ /8 WYE IEC C- Inlet ( Cord) /6* 25 or 2 Pole/ Wire /6* /2* Pole/4 Wire ~ 2 Pole/ Wire /2* /2* Pole/4 Wire ~ 2 Pole/ Wire /6* /2* Pole/4 Wire ~ Cord ength tes: *Rating for CE Products **Quantity = # of Circuits Phone Target Price Comparable Competitive Unit Brand/Model# Power Input Quantity S 5-5R Duplex R Individual R Duplex R Duplex 25 5-R Individual 25 5-R 25 6-R Duplex 6-R 5-R 25 6-R IEC C- 5/0* 25 or IEC C-9 /6* 25 or Other - Please Specify Physical Configuration Dimensional imits ength Width Height Hardwire Options Quantity** Additional Information Mounting Orientation 6" Wire Tails with Removable Plate Flexible Conduit Terminal Block Horizontal Project Timeline Power Switch Monitoring - with Cover Current ocal - Current (Amps) Only - Scrolling Display (Volts, Amps, Watts, Power Factor) Environmental Circuit Breakers (required by NEC in some units) rd Party Testing - Compliance U isted Surge Supression Current Remote - Circuit evel - evel Remote Switching Isolated Ground UR - U Recognized FCC Part 5 Class A CE ne Required Other - Please Specify BEDEN. ( )

7 and Configuration Chart NEMA s and s Straight-Blade P 5-5R 25 5-P 5-R P 5-5R /8 x ~ WYE 2-P 2-R 25 5-P 5-R 2/400 x ~ WYE 22-P 22-R 25 5-P 5-R /8 x ~ WYE 2-P 2-R 6-P 6-R 2/400 x ~ WYE 22-P 22-R 6-P 6-R x ~ Delta 5-P 5-R 25/ 4-P 4-R 25/ 4-P 4-R 50 x ~ Delta /6* 25 or Twist-ock Straight-Blade Twist-ock Straight-Blade Straight-Blade 6-P 6-R Twist-ock Twist-ock California Style IEC s and s Power Inlet Power 5/0* 25 or /6* /2* 2P, W 2P, W /6* /2* 2P, W 2P, W /2* /2 2P, W 2P, W /6* 2/400* x ~ WYE /2* 2/400* x ~ WYE C-4 C- Pin & Sleeve Power Inlet Power C- C-9 Pin & Sleeve *Rating for CE Products What is -Phase WYE? -Phase Delta from 8V Source -Phase Delta from /8V Source X Phase X Phase Ground Z Phase Y Phase 8V (XY) Z Phase Ground 2-P 8V (XY) Y Phase 8V (ZX) 8V (ZX) Y Phase V (XN) 8V (YZ) A -Phase Delta is a 4-wire configuration consisting of -Phase conductors (X, Y and Z) and a Ground. Without the neutral present, only phase-to-phase wiring is possible. The potential between any 2-Phase conductors is typically 8V. Phase WYE Phase Delta X Phase Neutral 5-P A -Phase Delta /8V WYE is a 5-wire configuration consisting of -Phase conductors (X, Y and Z), Neutral and Ground. The potential between any 2-Phase conductors is 8V. The potential between any phase and neutral is V. This configuration can be wired to provide V, 8V or a combination of both voltages within one PDU..800.BEDEN. ( ) What is -Phase Delta? 8V (YZ) Z Phase V (YN) V (ZN) Neutral Ground 79

Power Distribution Units for Data Centers

Power Distribution Units for Data Centers WWW.SIEMON.COM Power Distribution Units for Data Centers PowerMax Power Distribution Units Siemon s PowerMax line of PDUs range from basic and metered for simple, reliable and cost-effective power distribution,

More information

CS-12HDE444C8 (Master) Key Features. CL-12HDE444C8 (Link)

CS-12HDE444C8 (Master) Key Features. CL-12HDE444C8 (Link) CS-12HDE444C8 (Master) CL-12HDE444C8 (Link) The Server Technology Smart PDU provides local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a per-phase basis while

More information

Power Distribution Units for Data Centers

Power Distribution Units for Data Centers BRC_PowerMax_INT_Draft_I.qxp_Layout 1 9/11/17 2:00 PM Page 2 Power Distribution Units for Data Centers WWW.SIEMON.COM PowerMax Power Distribution Units 2 Siemon s PowerMax line of PDUs range from basic

More information

G5 PDU Installation Guide

G5 PDU Installation Guide G5 PDU Installation Guide 1 Contents Before You Begin... 3 Overview... 3 Important Safety Information... 3 Required Tools... 5 Section 1 Introduction... 6 Classification Overview... 6 Features... 7 Form

More information

CS-10H0A413H3 (Master) Key Features. CL-10H0A413H3 (Link)

CS-10H0A413H3 (Master) Key Features. CL-10H0A413H3 (Link) CS-10H0A413H3 (Master) CL-10H0A413H3 (Link) The Server Technology Smart PDU provides local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a per-phase basis while

More information

CS-24VD-L30MA (Master) Key Features. CL-24VD-L30MA (Link)

CS-24VD-L30MA (Master) Key Features. CL-24VD-L30MA (Link) CS-24VD-L30MA (Master) CL-24VD-L30MA (Link) The Server Technology Smart PDU provides local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a per-phase basis while

More information

Metered Rack PDU Rack PDU, Metered, Zero U, 10A, 230V, (16) C13

Metered Rack PDU Rack PDU, Metered, Zero U, 10A, 230V, (16) C13 Metered Rack PDU Rack PDU, Metered, Zero U, 10A, 230V, (16) C13 APC Metered Rack PDU, Input: 230V, Input Connections: IEC-320 C14, Cord Length: 10 feet ( 3.05 meters ), Output: 230V, Output Connections:

More information

BCM2 Series Branch Circuit Monitors Quick Setup Guide

BCM2 Series Branch Circuit Monitors Quick Setup Guide BCM2 Series Branch Circuit Monitors Quick Setup Guide Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable

More information

ECO PDU Power Distribution Unit

ECO PDU Power Distribution Unit ECO PDU Distribution Unit PE6108/PE6208/PE8108/PE8208 ATEN has developed a new generation of green energy power distribution units (PDUs) to effectively increase the efficiency of data center power usage.

More information

PDU Inspired by Your Data Center. W IEC PDU Series

PDU Inspired by Your Data Center. W IEC PDU Series PDU Inspired by Your Data Center W IEC PDU Series Intelligent kwh PDU - W series Power Efficiency Management With today s increasing demand for high technology power management solutions, PDU kwh measurement

More information

QuickSpecs. HPE Metered and Switched Power Distribution Units (PDU) Overview

QuickSpecs. HPE Metered and Switched Power Distribution Units (PDU) Overview HPE Metered and Switched Power Distribution Units (PDU) Overview Looking for a power distribution unit that meets the demands of high temperature operating environments and provides monitoring and switching

More information

Models. Specifications

Models. Specifications CAN YOUR PDU PIVOT? TRUE INNOVATION. ONLY FROM SERVER TECH. You ve never seen anything like this before. Intro- TM ducing the PDU Power Pivot, the newest patented innovation from Server Tech, inventors

More information

Table of Contents. 1. Introduction Package Contents Function Installation Web Interface... 4

Table of Contents. 1. Introduction Package Contents Function Installation Web Interface... 4 User Manual Table of Contents 1. Introduction... 1 2. Package Contents... 2 3. Function... 3 4. Installation... 2 5. Web Interface... 4 1. Introduction The ServerLink PDU is a network ready device designed

More information

Configurable power distribution

Configurable power distribution Configurable power distribution 60 150 kva The easy-to-deploy for data centers with custom requirements Configured to order, factoryassembled power distribution for IT equipment in any size data center

More information

Prisma II Platform. Optoelectronics

Prisma II Platform. Optoelectronics Optoelectronics Prisma II Platform Description In optical transmission systems, the network platform forms the foundation of the product family. The Prisma II platform provides network operators with the

More information

SmartOnline 240/208/120V 8kVA 5.6kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, Split-Phase input, Bypass Switch

SmartOnline 240/208/120V 8kVA 5.6kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, Split-Phase input, Bypass Switch SmartOnline 240/208/120V 8kVA 5.6kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, Split-Phase input, Bypass Switch MODEL NUMBER: SU8000RT4U Description Tripp Lite 8kVA SmartOnline

More information

Tripp Lite PDUs POWER DISTRIBUTION UNITS. Reliable rack power distribution for high-density IT environments. Introduction 2-3.

Tripp Lite PDUs POWER DISTRIBUTION UNITS. Reliable rack power distribution for high-density IT environments. Introduction 2-3. POWER DISTRIBUTION UNITS Tripp Lite rack power distribution for high-density IT environments. Introduction 2-3 Basic 4 Metered 5 Monitored 6 Switched 7 ATS 8 Hot-Swap 8 INTRODUCTION Tripp Lite Rack increase

More information

Excel Power Distribution

Excel Power Distribution www.excel-networking.com Excel Power Distribution Section 7 In this Section: Pages Power Distribution Units 154 Efficiency Measurements 154 Excel Modular PDU Range 155 Excel Standard PDUs 156 Excel Intelligent

More information

Deploying High Power to IT Equipment Racks

Deploying High Power to IT Equipment Racks 2012 Raritan Inc. Table of Contents Overview Page 3 Trends in Data Center Power Deployment Page 3 Drivers for High Power Racks Page 3 Data Center Power Distribution Around the World Page 4 What Is High

More information

GFCI (RCD) RECEPTACLES AND PLUGS 2 Pole 3 Wire Grounding

GFCI (RCD) RECEPTACLES AND PLUGS 2 Pole 3 Wire Grounding GFCI (RCD) RECEPTACLES AND PLUGS 2 Pole 3 Wire Grounding AU1-10R AU1-10P FR1-R EU1-P Cat. No. Drawing Configuration Australian GFCI (RCD) angle plug. trip. 10 ampere 230 volt, 50 Hz. 20 watt maximum. Test

More information

Switched Rack Power Distribution Unit

Switched Rack Power Distribution Unit Switched Rack Power Distribution Unit AS-216-520-30A-L530 Installation and Quick Start Contents Product Description and Inventory...................... 1 AS-216-520-30A-L530....................... 1 Additional

More information

ECO PDU. Features. PE5220sA

ECO PDU. Features. PE5220sA ECO PDU PE5220s As part of its NRGence line, ATEN has developed a new generation of green energy power distribution units (PDUs) to effectively increase the efficiency of data center power usage. The NRGence

More information

EnerSure Installation Guide

EnerSure Installation Guide EnerSure Installation Guide Danger!!! The electrical components of this system may contain voltage and /or amperage sufficient to injure or kill. Installation is only to be performed by a licensed, bonded

More information

C2W36CE-DQME2M99 (Master) C2X36CE-DQME2M99 (Expansion) Key Features

C2W36CE-DQME2M99 (Master) C2X36CE-DQME2M99 (Expansion) Key Features C2W36CE-DQME2M99 (Master) C2X36CE-DQME2M99 (Expansion) The Server Technology PRO2 Switched PDU provides control of outlet power and local LED input current monitoring, allowing IT personnel to determine

More information

Instruction Manual Rack Power Distribution Unit. J, VHV Series

Instruction Manual Rack Power Distribution Unit. J, VHV Series Instruction Manual Rack Power Distribution Unit J, VHV Series Geist Manufacturing 1821 Yolande Ave., Lincoln, NE 68521 800.432.3219 402.474.3400 F: 402.474.4369 www.geistmfg.com Contents Contents...2 Specifications...3

More information

Avanti HP Series Centrifuges Preinstallation

Avanti HP Series Centrifuges Preinstallation J3HP-TB-001AC May 2009 Avanti HP Series Centrifuges Preinstallation INTRODUCTION Purchase of an Avanti HP series high performance centrifuge includes installation and Basic Instrument Training for two

More information

Solutions Guide for Cisco UCS B and C Series Servers

Solutions Guide for Cisco UCS B and C Series Servers Solutions Guide for Cisco UCS B and C Series Servers The Cisco Unified Computing System is a next-generation data center platform that unites compute, network, storage access, and virtualization into a

More information

QuickSpecs. HP Intelligent Power Distribution Unit (ipdu) Overview

QuickSpecs. HP Intelligent Power Distribution Unit (ipdu) Overview Overview You cannot control what you cannot monitor. The new brings state of the art management and control to rack mounted power distribution units (PDU) to prevent over provisioning of power from restricting

More information

550VA Audio/Video Backup Power Block - Exclusive UPS Protection for Structured Wiring Enclosure

550VA Audio/Video Backup Power Block - Exclusive UPS Protection for Structured Wiring Enclosure 550VA Audio/Video Backup Power Block - Exclusive UPS Protection for Structured Wiring Enclosure MODEL NUMBER: AV550SC Highlights 4 AC outlets (including 1 delayon outlet for router) Automatic recycle/reset

More information

PM Series Power Meter

PM Series Power Meter PM Series Power Meter Quick Setup Guide - PMC-1000, PMC- 1001, PMM-1000, PMB-1960 Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See

More information

IBM eserver System x and BladeCenter IBM DPI PDU+ Power Distribution Units. 10/9/ IBM Corporation

IBM eserver System x and BladeCenter IBM DPI PDU+ Power Distribution Units. 10/9/ IBM Corporation IBM eserver System x and BladeCenter IBM DPI PDU+ Power Distribution Units 10/9/2007 Agenda System x Options Program and PDU market overview What is a PDU? Why do you need an IBM DPI PDU? IBM DPI PDU offering

More information

Retired. Full Rack Vertical PDU Model (Ideal for 36U to 47U racks)

Retired. Full Rack Vertical PDU Model (Ideal for 36U to 47U racks) Overview The HP Monitored PDUs allow administrators and facility personnel to monitor current draw directly at the rack and per PDU. HP Monitored PDUs are available in both 1 phase and 3 phase and in single

More information

HP Rackmountable 3 Phase Uninterruptible Power Systems Overview

HP Rackmountable 3 Phase Uninterruptible Power Systems Overview Overview Crowded data centers and racks filled to capacity with storage devices, monitors, servers communications devices, and other equipment are driving the need for uninterruptible power with increased

More information

SmartZone Gateway- Enabled M Series Rack PDU

SmartZone Gateway- Enabled M Series Rack PDU SmartZone Gateway- Enabled M Series Rack PDU User Manual Release 1.0 Issue 1.0 Copyright 2014 Panduit Corp. All rights reserved. No part of this book shall be reproduced, stored in a retrieval system,

More information

PD-6506, PD & PD-6524

PD-6506, PD & PD-6524 PD-6506, PD-6512 & PD-6524 User Guide Notice The information contained herein is believed to be accurate and reliable at the time of printing. However, due to ongoing product improvements and revisions,

More information

Server Technology Inc.

Server Technology Inc. Server Technology Inc. Alternating Phase Power Distribution at the Data Center Rack PDU White Paper STI-100-012 2013-April-18 By Steve Hammond, Product Manager, Server Technology Headquarters Server Technology,

More information

Thermal-Magnetic Circuit Breaker 2216-S

Thermal-Magnetic Circuit Breaker 2216-S Thermal-Magnetic Circuit Breaker 226-S Description One and two pole thermal-magnetic circuit breaker in compact design with slide actuator, trip-free mechanism, various trip characteristics and optional

More information

Power Monitoring in the Data Centre

Power Monitoring in the Data Centre Power Monitoring in the Data Centre Fixed or Wireless Steve Strange RCDD ANIXTER INTERNATIONAL Agenda Energy Consumption Case Study Reasons to Monitor Power Monitoring Environmental Monitoring Asset Tags

More information

SLI 15 Inverter Series Data Sheet 1500 Watt, 1U Compact Inverters

SLI 15 Inverter Series Data Sheet 1500 Watt, 1U Compact Inverters Applications Telecom IT Industrial Safety in compliance with IEC60950:1999, 3 rd edition; EN60950:2000; UL60950, 3 rd edition; CSA Standard C22.2 No.60950-00, 3 rd edition Features New, compact design:

More information

iconverter 2-Module Power Chassis

iconverter 2-Module Power Chassis iconverter 2-Module Power Chassis User Manual 38 Tesla, Irvine, CA 92618 USA Phone: (949) 250-6510; Fax: (949) 250-6514 Page 1 Warning The operating description in this Instruction Manual is for use by

More information

Cisco Redundant Power System 2300

Cisco Redundant Power System 2300 Data Sheet Cisco Redundant Power System 2300 The Cisco Redundant Power System 2300 (RPS 2300) increases availability for converged data, voice, and video networks. The system delivers power supply redundancy

More information

Host Controller: HST-4002

Host Controller: HST-4002 The Host Controller (HST-00) within a Savant System provides numerous functions including highlevel automation and control functions, user interface interpretations, system administration, and monitoring.

More information

Increasing Data Center Efficiency by Using Improved High Density Power Distribution

Increasing Data Center Efficiency by Using Improved High Density Power Distribution Increasing Data Center Efficiency by Using Improved High Density Power Distribution By Neil Rasmussen White Paper #128 Revision 1 Executive Summary A new approach to power distribution for high density

More information

Summit Virtual Chassis Design and Installation Guide

Summit Virtual Chassis Design and Installation Guide Summit Virtual Chassis Design and Installation Guide Extreme Networks, Inc. 10460 Bandley Drive Cupertino, California 95014 (888) 257-3000 http://www.extremenetworks.com Published: June 1998 Part No: 120031-00

More information

SmartZone Rack Energy Kits Energy and Environmental Monitoring for Small Data Centers

SmartZone Rack Energy Kits Energy and Environmental Monitoring for Small Data Centers SmartZone Rack Energy Kits Energy and Environmental Monitoring for Small Data Centers SmartZone Rack Energy Kits Energy and Environmental Monitoring for Small Data Centers SmartZone Rack Energy Kits Features:

More information

Power distribution solutions for the ProLiant DL580 G2 server

Power distribution solutions for the ProLiant DL580 G2 server Power distribution solutions for the ProLiant DL580 G2 server Introduction... 2 Symbols in text... 2 Executive summary... 2 Glossary... 2 ProLiant DL580 G2 server power requirements... 3 Power distribution

More information

Rack Power Distribution. Rack power distribution offerings for entry-level networking equipment and high-density server and blade environments

Rack Power Distribution. Rack power distribution offerings for entry-level networking equipment and high-density server and blade environments Rack Power Distribution Rack power distribution offerings for entry-level networking equipment and high-density server and blade environments Wiring Closet/Server Rooms IP Telephony High Density Small/Medium

More information

SLI 15 INVERTER SERIES, 1500 W

SLI 15 INVERTER SERIES, 1500 W SLI 15 INVERTER SERIES, 1500 W FEATURES DESCRIPTION New, compact design: 1U height x 19" width x 14.94" depth; 19" rack-mountable High efficiency: up to 93% True sine wave output Parallelable output with

More information

Server Technology, Inc.

Server Technology, Inc. Server Technology, Inc. Planning, Implementing and Application of Cabinet Power Distribution Units White Paper STI-100-007 Headquarters Server Technology, Inc. 1040 Sandhill Drive Reno, NV 89521 United

More information

SmartOnline 120V 3kVA 2.7kW On-Line Double- Conversion UPS, 2U Rack/Tower, Extended Run, Network Card Option, ENERGY STAR

SmartOnline 120V 3kVA 2.7kW On-Line Double- Conversion UPS, 2U Rack/Tower, Extended Run, Network Card Option, ENERGY STAR SmartOnline 120V 3kVA 2.7kW On-Line Double- Conversion UPS, 2U Rack/Tower, Extended Run, Network Card Option, ENERGY STAR MODEL NUMBER: SU3000RTXL2U Highlights Zero transfer time between AC power and battery

More information

SmartPro 230V 5kVA 3.75kW Line-Interactive Sine Wave UPS, 3U, Extended Run, Network Card Options, USB, DB9

SmartPro 230V 5kVA 3.75kW Line-Interactive Sine Wave UPS, 3U, Extended Run, Network Card Options, USB, DB9 SmartPro 230V 5kVA 3.75kW Line-Interactive Sine Wave UPS, 3U, Extended Run, Network Card Options, USB, DB9 MODEL NUMBER: SMX5000XLRT3U Highlights 5kVA / 5000VA line interactive 3U rack/tower UPS; Sine

More information

DCIM Data Center Infrastructure Management

DCIM Data Center Infrastructure Management DCIM Data Center Infrastructure Management Part 3 Operational Management Moves Adds and Changes & Electrical Infrastructure November 5, 2013 Presented by Julius Neudorfer Sponsored by Today s Topics Operational

More information

Monitored econnect PDU

Monitored econnect PDU Protecting your technology investment. For use in data centers and equipment room racks and cabinets. Provides continuous, automated monitoring of each PDU to provide measurement at the rack level. Integration

More information

Safety Systems Safety Integrated

Safety Systems Safety Integrated 3SE2 / SE3 Molded plastic /metal enclosure with separate actuator Application Safety interlock switches with separate actuator are used where the position of doors, covers or safety screens must be monitored

More information

Modular PDU Smart metering for your IT

Modular PDU Smart metering for your IT Modular PDU Smart metering for your IT Extremely flexible The modular PDU 2 Rittal modular PDU Modern IT equipment is constantly evolving, requiring permanent adjustments to the IT infrastructure. With

More information

Isobar 6-Outlet Surge Protector, 6 ft. Cord with Right-Angle Plug, 3300 Joules, Diagnostic LEDs, Metal Housing

Isobar 6-Outlet Surge Protector, 6 ft. Cord with Right-Angle Plug, 3300 Joules, Diagnostic LEDs, Metal Housing Isobar 6-Outlet Surge Protector, 6 ft. Cord with Right-Angle Plug, 3300 Joules, Diagnostic LEDs, Metal Housing MODEL NUMBER: ISOBAR6 Highlights 6 NEMA 5-15R outlets in exclusive isolated filter banks Network-grade

More information

PIX 515/515E. PIX 515/515E Product Overview CHAPTER

PIX 515/515E. PIX 515/515E Product Overview CHAPTER CHAPTER 4 PIX 515/515E This chapter describes how to install the PIX 515/515E, and includes the following sections: PIX 515/515E Product Overview Installing a PIX 515/515E PIX 515/515E Feature Licenses

More information

SmartPro 120V 1.05kVA 705W Line-Interactive UPS, Tower, 120V, USB port

SmartPro 120V 1.05kVA 705W Line-Interactive UPS, Tower, 120V, USB port SmartPro 120V 1.05kVA 705W Line-Interactive UPS, Tower, 120V, USB port MODEL NUMBER: SMART1050 Highlights 1.05kVA / 1050VA line interactive tower UPS system 120V output, Corrects brownouts and overvoltages

More information

QuickSpecs. HP Performance Optimized Datacenter (POD) 20ce. Overview. Retired

QuickSpecs. HP Performance Optimized Datacenter (POD) 20ce. Overview. Retired Overview The HP Performance-Optimized Data Center (HP POD) is a containerized datacenter equipped with power infrastructure, cooling and IT power distribution. The HP POD can be deployed within weeks instead

More information

AD-8923-BCD. Remote Controller (BCD) INSTRUCTION MANUAL 1WMPD

AD-8923-BCD. Remote Controller (BCD) INSTRUCTION MANUAL 1WMPD AD-8923-BCD Remote Controller (BCD) INSTRUCTION MANUAL 1WMPD4002137 2010 A&D Company, Limited. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, or translated

More information

YourPDU. by Schleifenbauer. This PDF has been optimised for viewing with Acrobat Reader. Click here to download it for free.

YourPDU. by Schleifenbauer. This PDF has been optimised for viewing with Acrobat Reader. Click here to download it for free. This PDF has been optimised for viewing with Acrobat Reader. Click here to download it for free. Your PDU 3..7 1. 2. Our advanced technology offers you accurate measurements and detailed data, so that

More information

Product Brochure. Eaton epdu G3 Managed

Product Brochure. Eaton epdu G3 Managed Product Brochure Eaton epdu G3 Managed Advanced power management and precision control The Eaton epdu third generation (G3) Managed models build on Eaton s existing state-of-the-art epdu G3 technology

More information

Liebert MPH TM Managed Rack-PDU Systems monitoring and control

Liebert MPH TM Managed Rack-PDU Systems monitoring and control Liebert MPH TM Managed Rack-PDU Systems monitoring and control The Liebert MPH TM Managed Rack PDU is a power supply system with monitoring and control functions. The housing consists of a robust sheet

More information

MODEL NUMBER: B IP2-K

MODEL NUMBER: B IP2-K Free NetCommander-AXS Management Software is available for access and control of all of your Tripp Lite NetCommander IP KVM switches (B070 and B072 series). From a single interface, you can access server

More information

SmartOnline 208 & 120V 5kVA 4.5kW Double- Conversion UPS, 6U Rack/Tower, Extended Run, Network Card Slot, USB, DB9 Serial

SmartOnline 208 & 120V 5kVA 4.5kW Double- Conversion UPS, 6U Rack/Tower, Extended Run, Network Card Slot, USB, DB9 Serial SmartOnline 208 & 120V 5kVA 4.5kW Double- Conversion UPS, 6U Rack/Tower, Extended Run, Network Card Slot, USB, DB9 Serial MODEL NUMBER: SU5000RT4UTF Highlights 5kVA / 5000VA / 4500 watt online double-conversion

More information

IEC Contactors. Auxiliary Contact Blocks GENERAL

IEC Contactors. Auxiliary Contact Blocks GENERAL IEC Contactors Auxiliary Contact Blocks GENERAL Description 3RH19 Auxiliary contact blocks The 3RH19 auxiliary contact blocks are available in 1, 2, 3 and 4-pole front mount versions and 2-pole side mount

More information

SmartOnline 120V 1.5kVA 1.2kW Double- Conversion UPS, 2U Rack/Tower, Extended Run, Network Card Options, USB, DB9 Serial

SmartOnline 120V 1.5kVA 1.2kW Double- Conversion UPS, 2U Rack/Tower, Extended Run, Network Card Options, USB, DB9 Serial SmartOnline 120V 1.5kVA 1.2kW Double- Conversion UPS, 2U Rack/Tower, Extended Run, Network Card Options, USB, DB9 Serial MODEL NUMBER: SU1500RTXL2UA Highlights 1500VA / 1.5kVA / 1200 watt on-line double-conversion

More information

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE IMPORTANT! Please read all the information on this sheet. SAVE THESE INSTRUCTIONS! NOTICE BEFORE USING READ INSTRUCTIONS COMPLETELY. TO BE INSTALLED BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH NATIONAL

More information

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS SECTION 262816 - ENCLOSED SWITCHES AND CIRCUIT BREAKERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

QuickSpecs. HPE Intelligent Power Distribution Unit (PDU) Overview

QuickSpecs. HPE Intelligent Power Distribution Unit (PDU) Overview Overview You cannot control what you cannot monitor. The new brings state of the art management and control to rack mounted PDUs to prevent over provisioning of power which may restrict growth in your

More information

SmartPro LCD 120V 1500VA 900W Line- Interactive UPS, AVR, 2U Rack/Tower, LCD, USB, DB9 Serial, 8 Outlets

SmartPro LCD 120V 1500VA 900W Line- Interactive UPS, AVR, 2U Rack/Tower, LCD, USB, DB9 Serial, 8 Outlets SmartPro LCD 120V 1500VA 900W Line- Interactive UPS, AVR, 2U Rack/Tower, LCD, USB, DB9 Serial, 8 Outlets MODEL NUMBER: SMART1500LCD Highlights Supports a half-load (450W) up to 11.8 min. during power outage

More information

1.2 Intel Server Chassis SC5400BASE Summary

1.2 Intel Server Chassis SC5400BASE Summary Introduction Intel Server Chassis SC5400BASE Customization Panels Unpainted Rack Top Cover Slim Line CDROM/USB Floppy Kit Intel Server Chassis SC5400BRP 10-pack Branding / Customization Panels Unpainted

More information

Emerson Network Power MPH2 Rack PDU

Emerson Network Power MPH2 Rack PDU Emerson Network Power MPH2 Rack PDU User Manual 1 MPH2 121.1V 359W MPH2 Managed Rack Power Distribution 2.96A RX L1 L2 L3 TX 2kWh i TABLE OF CONTENTS IMPORTANT SAFETY INSTRUCTIONS................................................1

More information

PANAMAX RETAIL PRICE LIST Effective January 1,

PANAMAX RETAIL PRICE LIST Effective January 1, MAX COMPONENT FAMILY - RACK MOUNTABLE SURGE PROTECTION PLUS LINE CONDITIONER FOR A/V & SAT SYSTEMS M4300 MAX 4300-1U Rackmount; 7 pure AC power outlets; (3 always on, 4 switched) 1 Signal Perfect SAT coax

More information

Sockets and accessories for auxiliary relays

Sockets and accessories for auxiliary relays √ćNDEX Sockets and accessories for auxiliary relays User manual Sockets and accessories for auxiliary relays User manual 1 651.601.437 Rev: 8 Date: 09/08/2016 ARTECHE Power Grid, S.L. This document, including

More information

Smart-UPS APC Smart-UPS 750VA USB & Serial RM 1U 120V

Smart-UPS APC Smart-UPS 750VA USB & Serial RM 1U 120V Smart-UPS APC Smart-UPS 750VA USB & Serial RM 1U 120V APC Smart-UPS, 480 Watts / 750 VA,Input 120V / Output 120V, Interface Port DB-9 RS-232, SmartSlot, USB, Rack Height 1 U Includes: CD with software,

More information

Power Control and Distribution

Power Control and Distribution Power Control and Distribution MasterSwitch Series Remote power distribution units for network administrators, Co-Location facilities, ISPs, and applications where remote control of outlets is required

More information

MOBILE CONNECTOR - GEN 2 OWNER'S MANUAL

MOBILE CONNECTOR - GEN 2 OWNER'S MANUAL MOBILE CONNECTOR - GEN 2 OWNER'S MANUAL UNITED STATES Contents Safety Information... 2 Save These Important Safety Instructions... 2 Warnings...2 Cautions...3 General Information... 4 Mobile Connector

More information

High Power over Ethernet Midspans PD Port Model PD Port Model

High Power over Ethernet Midspans PD Port Model PD Port Model Data and Power on a Single Line High Power over Ethernet Midspans PD-8006-6 Port Model PD-8012-12 Port Model User Guide Notice The information contained herein is believed to be accurate and reliable at

More information

POS Series 120V 50/60Hz 500VA 300W Standby UPS, Tower, USB port, 6 Outlets, TEL/DSL Protection

POS Series 120V 50/60Hz 500VA 300W Standby UPS, Tower, USB port, 6 Outlets, TEL/DSL Protection POS Series 120V 50/60Hz 500VA 300W Standby UPS, Tower, USB port, 6 Outlets, TEL/DSL Protection MODEL NUMBER: POS500 Highlights 500VA low-profile tower 120V standby UPS Maintains AC output during power

More information

Product brochure. Eaton epdu G3. Simplify installation. Enhance operation. Maximize control.

Product brochure. Eaton epdu G3. Simplify installation. Enhance operation. Maximize control. Product brochure Eaton epdu G3 Simplify installation. Enhance operation. Maximize control. Power distribution made better by Eaton The Eaton epdu G3 rack mounted power distribution units (PDUs) provide

More information

SmartPro LCD 120V 1.5kVA 900W Line-Interactive UPS, AVR, 2U Rack/Tower, LCD Display, USB, DB9 Serial

SmartPro LCD 120V 1.5kVA 900W Line-Interactive UPS, AVR, 2U Rack/Tower, LCD Display, USB, DB9 Serial SmartPro LCD 120V 1.5kVA 900W Line-Interactive UPS, AVR, 2U Rack/Tower, LCD Display, USB, DB9 Serial MODEL NUMBER: SMART1500LCD Highlights 1500VA / 1.5kVA 2U rack/tower 120V line interactive UPS with LCD

More information

HPE BladeSystem c3000 Enclosure Quick Setup Instructions

HPE BladeSystem c3000 Enclosure Quick Setup Instructions HPE BladeSystem c3000 Enclosure Quick Setup Instructions Part Number: 446990-007 2 Site requirements Select an installation site that meets the detailed installation site requirements described in the

More information

3M ID 3000 System. ID 3128 block. Disconnection module. ID 3100 block Wire guide housing

3M ID 3000 System. ID 3128 block. Disconnection module. ID 3100 block Wire guide housing 3M ID 3000 System ID 3128 block Disconnection module ID 3100 block Wire guide housing 71 Disconnection element 72 The ID 3000 connection system is the latest generation of insulation displacement connector

More information

OmniSmart 120V 330VA 225W UL Medical Grade Line-Interactive UPS, Tower, DB9 Serial

OmniSmart 120V 330VA 225W UL Medical Grade Line-Interactive UPS, Tower, DB9 Serial OmniSmart 120V 330VA 225W UL 60601-1 Medical Grade Line-Interactive UPS, Tower, DB9 Serial MODEL NUMBER: OMNISMART350HG Highlights 330VA line interactive tower UPS Maintains sine-wave 120V nominal output

More information

EMC1600 Series Media Converter and Ethernet Extender Chassis

EMC1600 Series Media Converter and Ethernet Extender Chassis EMC1600 Series Media Converter and Ethernet Extender Chassis User s Manual Preface This manual describes how to install and use the 16-Bay Media Converter and Ethernet Extender Chassis. This chassis is

More information

SmartOnline 208/240V 6kVA 5.4kW Double- Conversion UPS, 4U Rack/Tower, Extended Run, Network Card Options, USB, DB9, Bypass Switch, L6-30R & L6-20R

SmartOnline 208/240V 6kVA 5.4kW Double- Conversion UPS, 4U Rack/Tower, Extended Run, Network Card Options, USB, DB9, Bypass Switch, L6-30R & L6-20R SmartOnline 208/240V 6kVA 5.4kW Double- Conversion UPS, 4U Rack/Tower, Extended Run, Network Card Options, USB, DB9, Bypass Switch, L6-30R & L6-20R MODEL NUMBER: SU6000RT4UHV Highlights Completely user

More information

AI-102. IR Illuminator. Installation Guide. Rev IP Surveillance

AI-102. IR Illuminator. Installation Guide. Rev IP Surveillance AI-102 IR Illuminator Installation Guide Rev. 1.1 IP Surveillance Revision History: Rev. 1.0: Initial release Rev. 1.1: Changed effective IR range and power consumption. AI-102 Tube Type Infrared Illuminator

More information

New Product Release. Integrated Intelligent Power Distribution.

New Product Release. Integrated Intelligent Power Distribution. Integrated Intelligent Power Distribution. i-pdu has been developed to seamlessly integrate with Cooper B-Line s i-box and i-pal systems (access control and environmental monitoring system) providing the

More information

AX3000 Platine Terminal Ethernet TCP/IP

AX3000 Platine Terminal Ethernet TCP/IP AX3000 Platine Terminal Ethernet TCP/IP Model 80 Installation Guide January 2012 - Ref: I80E0922-2 Model AX3000/M80 Type EA The reproduction of this material, in part or whole, is strictly prohibited.

More information

SmartPro 230V 3kVA 2.7kW Line-Interactive Sine Wave UPS, 2U, Extended Run, Network Card Options, LCD, USB, DB9

SmartPro 230V 3kVA 2.7kW Line-Interactive Sine Wave UPS, 2U, Extended Run, Network Card Options, LCD, USB, DB9 SmartPro 230V 3kVA 2.7kW Line-Interactive Sine Wave UPS, 2U, Extended Run, Network Card Options, LCD, USB, DB9 MODEL NUMBER: SMX3000XLRT2UA Highlights 3kVA / 3000VA / 2700W line interactive 2U rack/tower

More information

Internet Office 120V 750VA 450W Standby UPS, Ultra-Compact Desktop, USB

Internet Office 120V 750VA 450W Standby UPS, Ultra-Compact Desktop, USB Internet Office 120V 750VA 450W Standby UPS, Ultra-Compact Desktop, USB MODEL NUMBER: INTERNET750U Highlights 750VA ultra-compact 120V standby UPS Maintains AC output during power failures 6 UPS battery

More information

Line A. Inverse parallel scrs. Load a FUSION. Line B SCR POWER. O delta CONTROLLERS. Line c. inverse parallel scrs. Load C. FUSION Brochure Rev 3.

Line A. Inverse parallel scrs. Load a FUSION. Line B SCR POWER. O delta CONTROLLERS. Line c. inverse parallel scrs. Load C. FUSION Brochure Rev 3. Line A Inverse parallel scrs Load a Line B FUSION SCR POWER O delta CONTROLLERS Line c inverse parallel scrs Load C FEATURES Auto-Ranging Input Voltage 24-600 VAC, 45-65 Hz AC or DC Output AC Models: 50-1200

More information

SECTION PANELBOARDS

SECTION PANELBOARDS SECTION 16450 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes requirements for panelboards providing fault interrupting capability and overcurrent protective devices. 1.02 REFERENCE STANDARDS A.

More information

29 $ Manual Motor Starters FREESHIPPING. MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame.

29 $ Manual Motor Starters FREESHIPPING.  MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame. www.factorymation.com/motorcontrols MOTOR CONTROLS 25 Manual Motor Starters High interrupt capacity Din rail and surface mounting Lockable handle (OFF position) IP20 finger safe terminals Class 10 thermal

More information

Product Specifications

Product Specifications Product Specifications Models: USC-10001, USC-10002 USC-20001, USC-20002 USC-30001, USC-30002 Guide Specification for UniStar C Series Rack/Universal 1, 2, 3Kva Single-Phase, On-Line Double Conversoin

More information

QuickSpecs. HPE Intelligent Power Distribution Unit (PDU) Overview

QuickSpecs. HPE Intelligent Power Distribution Unit (PDU) Overview Overview You cannot control what you cannot monitor. The new brings state of the art management and control to rack mounted PDUs to prevent over provisioning of power which may restrict growth in your

More information

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors B Curve NC100H Supplementary Protectors Rating 1P 2P 3P 4P 80 MG27164 MG27175 MG27186 MG27197 MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors C Curve NC100H Supplementary Protectors

More information

MATRIX SERVSWITCH. You have a crowded server. Affordable 2- or 4-user multiplatform switching. greater security.

MATRIX SERVSWITCH. You have a crowded server. Affordable 2- or 4-user multiplatform switching. greater security. 2004. All rights reserved. Black Box Corporation. Black Box Corporation 1000 Park Drive Lawrence, PA 15055-1018 Tech Support: 724-746-5500 www.blackbox.com e-mail: info@blackbox.com MATRIX SERVSWITCH 5

More information

AVR Series 120V 750VA 450W Ultra-Compact Line-Interactive UPS with USB port

AVR Series 120V 750VA 450W Ultra-Compact Line-Interactive UPS with USB port AVR Series 120V 750VA 450W Ultra-Compact Line-Interactive UPS with USB port MODEL NUMBER: AVR750U Highlights 750VA ultra-compact 120V line interactive UPS Corrects brownouts and overvoltages from 83V to

More information