Protective Relays & SCADA Systems
|
|
- Shannon Ramsey
- 6 years ago
- Views:
Transcription
1 14 SWITCHGEAR Protective Relays & SCADA Systems SCADA Substation Automation SICAM PAS & PQ Analyzer SICAM PAS (Power Automation System) is a complete substation automation control and protection system for HV and MV switchgear (i.e., >600 volts) used in electric utility and industrial facility substations. SICAM PAS offers many time and cost saving benefits for entities along the switchgear value chain including, electric utilities, industrial plant owners, switchgear manufacturers, designers, integrators, panel builders, installers and OEMs. Key Features n Integrated substation automation system for SCADA monitoring, control and system protection. n Fully compliant with the IEC industry design standard. n Automated Power Quality and protection relay fault record retrieval and data reporting (supports NERC PRC-002). n Substation Human Machine Interface (HMI) for visualization, alarm handling and control using graphical displays. n NERC CIP cyber security compliance tools. n Redundant server option for greater reliability. Benefits n SICAM PAS saves designers, panel builders and OEMs time and money to deploy standardized and reusable protection and control systems. n SICAM PAS is interoperable with third-party devices using IEC 61850, DNP, OPC and Modus communication protocols. n The IEC design standard results in a significant reduction of panel wiring which saves in material costs and installation and test time. n IEC also provides the means to bench test and debug the system and protection design before the switchgear is deployed in the substation, which significantly reduces the project schedule and on-site integration risk. n Plant owners can see savings through automated power quality reporting. SICAM PAS Substation Server SICAM PAS works on industrialstandard hardware with the Microsoft Windows operating systems. The advantages of this platform are low hardware and software costs, ease of operation, scalability, flexibility and General constantly available support. With the powerful real-time data distribution system, applications can be allocated among several computers, thus boosting performance, connectivity and availability. A database system stores and organizes the data basis (e.g. configuration data, administrative status data, etc.). The device master function for communication with Intelligent Electronic Devices (IEDs) supports a large number of well established protocols. The SICAM PAS data normalization function allows conversions such as measured-value filtering, threshold value calculation and linear characteristics. SICAM PAS CC HMI SICAM PAS CC is used for process visualization. Specifically designed for energy applications, it assists the operating personnel in optimizing the operations management. It provides quick visualization and response to substation conditions. SICAM PAS CC is based on SIMATIC WinCC, one of the leading process visualization systems that is used in industrial automation world. DNP HMI Client Station Bus IEC (Ethernet) Siemens PLC s Modbus, DNP, Profibus DP Protection, Control, Metering DNP Protection, Control, Metering Protection, Control, Metering Peer to Peer or Goose Capable Siemens Siprotec Relay (see Siprotec specific info on page 14-29) Siemens Industry, Inc. SPEEDFAX 2011 Product Catalog
2 Overview High-performance protective relaying comes into its own when it s a question of minimizing power system operationg costs. Uncomplicated operation, convenient commissioning tools and flexible communication are all important elements when service and maintenance costs have to be reduced. The Siemens SIPROTEC family with its protection relays and bay control units is an integrated system for medium-voltage to extra-high-voltage applications. Numerical protection systems are nothing new; after all, Siemens has more than 25 years experience in this field. Although system hardware is still often referred to as protection equipment or units as was once the case with analog technology it can now do so much more. These relays not only handle fault detection and location tasks but also control, metering and monitoring functions. And it is these additional functions impossible before the advent of numerical technology which offer major cost-cutting potential. IEC SIPROTEC the standard for numerical protective relaying has established itself right across the market. Besides the common system platform and the unique DIGSI 4 service interface that may be used for all protective devices, it also supports the new IEC communication standard. A potential that offers more efficiency, easily and conveniently. With SIPROTEC relays and bay control units from Siemens we offer all the advantages of an expert and innovative partner in the field of protective relaying and substation automation. We bring you attractively priced intelligent solutions by paying particular attention to lowering your life cycle and system management costs. These solutions are the first ones available on the market with the international IEC standard. To enable you to profit from these advantages as quickly as possible, Siemens collaborated in the preparation of this international standard and made every effort to ensure no time was lost in bringing it out. The result is certainly worth a look, because SIPROTEC and other Power Automation products and General Siemens systems are available on the basis of the IEC standard and can even be retrofitted in systems supplied since System advantages n One bay, one unit The SIPROTEC 4 relay family offers fully integrated protection, control, monitoring, and automation functions incorporated in a single device. For many applications, this product contains all the functions you need to meet all your protection and control requirements with just one unit per bay, saving on investment and installation costs and enhancing availability. n DIGSI 4 one tool for all tasks and products DIGSI 4 is a computer program designed for all SIPROTEC relays. DIGSI 4 offers users a universal tool for all support tasks from setting and commissioning of devices to simple analysis and documentation of system faults. Our powerful analysis tool speeds up troubleshooting and supplies important service information. 14 SWITCHGEAR Siemens Industry, Inc. SPEEDFAX 2011 Product Catalog 14-29
3 ANSI List for Protective Relays 14 SWITCHGEAR 7SA522 7SA6 7SD600 7SD5 7SD610 7SJ45 7SJ46 7SJ600 7SJ62 7SK80 7VH60 7UT613 7UT63 7SS60 7SS52 7UM61 7VK61 Distance Pilot wire differential Line differential Overcurrent Motor protection Differential Generator and motor protection Breaker management Synchronizing Breaker failure Voltage, frequency 7VE6 7SV600 7RW600 ANSI No.* Protection functions 14 Locked rotor protection l l l l 21 Distance protection, phase l 21N Distance protection, earth (ground) l 21FL Fault locator l l l l l 24 Overfluxing (V/f protection) l l 25 Synchronizing, synchronism l l l l l l check 27 Undervoltage l l l l l l l l l l l l 27/34 Stator earth-fault 3rd harmonic 32 Directional power l l l l l 32F Forward power l l l l l l 32R Reverse power l l l l l 37 Undercurrent or underpower l 40 Loss of field l 46 Load unbalance, negative phase-sequence overcurrent l l l l 47 Phase-sequence voltage l l 48 Incomplete sequence, l l l l l locked rotor l l 49 Thermal overload l 49R Rotor thermal protection 49S Stator thermal protection 50 Instantaneous overcurrent l 50N Instantaneous earth-fault l overcurrent 50BF Breaker failure l l l l l l 51GN Zero speed and underspeed device 51 Overcurrent-time relay, phase l 51N Overcurrent-time relay, earth l 51M Load jam protection l l l l 51V Overcurrent-time relay, voltage controlled 59 Overvoltage l l l l l l l l l l l l 59N Residual voltage earth-fault l l l l l protection 59GN Stator earth-fault protection % Stator earth-fault protection (20 Hz) l 64R Rotor earth fault n Standard function l Optional ] ANSI/IEEE C37.2: IEEE Standard Electrical Power System Device Function Numbers Siemens Industry, Inc. SPEEDFAX 2011 Product Catalog
4 ANSI List for Protective Relays Distance Pilot wire differential Line differential Overcurrent Motor protection Differential Generator and motor protection 7SA522 7SA6 7SD600 7SD5 7SD610 7SJ45 7SJ46 7SJ600 7SJ62 7SK80 7VH60 7UT613 7UT63 7SS60 7SS52 7UM61 7VK61 7VE6 7SV600 7RW600 Breaker management Synchronizing Breaker failure Voltage, frequency ANSI No.* Protection functions 67 Directional overcurrent l l l l l 67N Directional earth-fault l l l l overcurrent l l l l l 67G Stator earth-fault directional overcurrent 68 Power swing detection l l l l 74TC Trip circuit supervision l l l 78 Out-of-step protection 79 Auto-reclosure l l l l l l l l l l l 81 Frequency protection l l l l l l l l l 81R Rate-of-frequency-change protection l l l l l l l Vector jump supervision l l l 14 SWITCHGEAR 85 Carrier interface/remote trip l 86 Lockout function l 87G Differential protection generator 87T Differential protection l l transformer 87BB Differential protection busbar 87M Differential protection motor 87L Differential protection line Restricted earth-fault 87N l l l l l l protection n Standard function l Optional ] ANSI/IEEE C37.2: IEEE Standard Electrical Power System Device Function Numbers Only sensitive directional earth-fault overcurrent (67Ns). Siemens Industry, Inc. SPEEDFAX 2011 Product Catalog 14-31
5 Siemens Protective Relays - Quick Competitor Comparison by Application Motor Protection GE 239 7SK80 7SK8051-5EC96-3HD0+L0G GE 269 7SK80 7SK8051-5EC96-3HD0+L0G GE SK80 7SK8051-5EC96-3HD0+L0G GE 369 7SK80 SIMPRO-100-R-V GE 469 7SK80 and 7SJ601 SIMPRO-100-R-V/7SJ6015-4EA01-0AA0 Feeder Protection 14 SWITCHGEAR ABB CO (4 single phase) 7SJ45 (1 three phase) 7SJ4505-1EA00-1AA1 (1 three phase) 7SJ46 (1 three phase) 7SJ4605-1EA00-1AA0 (1 three phase) 7SJ601 (1 three phase) 7SJ6015-4EA01-0AA0 (1 three phase) ABB Microshield 7SJ600 7SJ6005-4EA00-0DA1 5-4EB00-1FA0 41-5EC96-3FC1+L0G 15-5EC90-1FA0+L0D 7SJ62 7SJ6215-5EC90-1FE0+L0D ABB DPU SJ62 7SJ6215-5EC90-1FE0+L0D 15-5EC90-1FE0+L0D 05-5EC92-1FE4+L0D ABB DPU-2000R 7SJ62 7SJ6215-5EC90-1FE0+L0D 15-5EC90-1FE0+L0D 05-5EC92-1FE4+L0D Basler BE3-51 (4 single phase) 7SJ45 (1 three phase) 7SJ4505-1EA00-1AA1 (1 three phase) 7SJ46 (1 three phase) 7SJ4605-1EA00-1AA0 (1 three phase) Basler BE1-51 (4 single phase) 7SJ45 (1 three phase) 7SJ4505-1EA00-1AA1 (1 three phase) 7SJ46 (1 three phase) 7SJ4605-1EA00-1AA0 (1 three phase) 7SJ601 (1 three phase) 7SJ6015-4EA01-0AA0 (1 three phase) Basler BE SJ600 7SJ6005-4EA00-0DA1 5-4EB00-1FA0 41-5EC96-3FC1+L0G 15-5EC90-1FA0+L0D Basler BE SJ62 7SJ6215-5EC90-1FE0+L0D 15-5EC90-1FE0+L0D 05-5EC92-1FE4+L0D GE MDP 7SJ45 7SJ4505-1EA00-1AA1 7SJ46 7SJ4605-1EA00-1AA0 7SJ601 7SJ6015-4EA01-0AA0 41-5EC96-3FC1+L0G GE 735 7SJ600 7SJ6005-4EA00-0DA1 5-4EB00-1FA0 41-5EC96-3FC1+L0G 15-5EC90-1FA0+L0D GE 750 7SJ62 7SJ6215-5EC90-1FE0+L0D 15-5EC90-1FE0+L0D 05-5EC92-1FE4+L0D GE F60 7SJ62 7SJ6215-5EC90-1FE0+L0D 15-5EC90-1FE0+L0D 05-5EC92-1FE4+L0D SEL 351A 7SJ62 7SJ6215-5EC90-1FE0+L0D 15-5EC90-1FE0+L0D 05-5EC92-1FE4+L0D SEL 351 7SJ62 7SJ6215-5EC90-1FE0+L0D 15-5EC90-1FE0+L0D 05-5EC92-1FE4+L0D SEL 351S 7SJ62 7SJ6215-5EC90-1FE0+L0D 15-5EC90-1FE0+L0D 05-5EC92-1FE4+L0D SEL 501 7SJ600 7SJ6005-4EA00-0DA1 5-4EB00-1FA0 41-5EC96-3FC1+L0G 15-5EC90-1FA0+L0D SEL 551 7SJ600 7SJ6005-4EA00-0DA1 5-4EB00-1FA0 41-5EC96-3FC1+L0G 15-5EC90-1FA0+L0D *Siemens catalog numbers in Bold are the preferred equivalent model. Siemens does not accept any liability for the information contained in this document Siemens Industry, Inc. SPEEDFAX 2011 Product Catalog
6 General Protection ABB GPU EC90-0BA0+L0D Basler BE1- GPS100 7UM61 7UM6115-5EC90-0CA0+L0D 15-5EC90-0BA0+L0D Beckwith M UM61 7UM6115-5EC90-0CA0+L0D 15-5EC90-0BA0+L0D Beckwith M EC90-0CA0+L0D GE 489 7UM61 7UM6115-5EC90-0CA0+L0D 15-5EC90-0BA0+L0D SEL 300G 7UM61 7UM6115-5EC90-0CA0+L0D 15-5EC90-0BA0+L0D Bus Protection ABB HU 7VH60 7VH6002-0EA20-0AA0 ABB CA 7VH60 7VH6002-0EA20-0AA0 ABB TPU2000R 7UT EC00-1AA0 Basler BE1-87 7UT EC00-1AA0 (3) 7VH60 7VH6002-0EA20-0AA0 GE PVD 7VH60 7VH6002-0EA20-0AA0 GE B30 7UT EC00-1AA0 SEL 387 7UT EC00-1AA0 Transformer Protection 14 SWITCHGEAR ABB HU (3) 7UT512 (1) 7UT5125-4GB11-0AA0 7UT513 (1) (1) 5-5EC00-1AA0 ABB CA (3) 7UT512 (1) 7UT5125-4GB11-0AA0 7UT513 (1) (1) 5-5EC00-1AA0 ABB TPU2000R 7UT512 7UT5125-4GB11-0AA0 7UT EC00-1AA0 Basler BE1-CDS 7UT EC00-1AA0 GE 745 7UT EC00-1AA0 GE T60 7UT EC00-1AA0 SEL 387 7UT EC00-1AA0 SEL 587 7UT512 7UT5125-4GB11-0AA0 7UT EC00-1AA0 Voltage/Frequency Protection Basler BE1-27 7RW600 and 7RW80 7RW EA00-0DA0 and 7RW8020-5EC96-1DA0+L0G Basler BE1-59 7RW600 and 7RW80 7RW EA00-0DA0 and 7RW8020-5EC96-1DA0+L0G Basler BE1-27/59 7RW600 and 7RW80 7RW EA00-0DA0 and 7RW8020-5EC96-1DA0+L0G Basler BE1-81O/U 7RW600 and 7RW80 7RW EA00-0DA0 and 7RW8020-5EC96-1DA0+L0G GE IAV 7RW600 and 7RW80 7RW EA00-0DA0 and 7RW8020-5EC96-1DA0+L0G GE IFV 7RW600 and 7RW80 7RW EA00-0DA0 and 7RW8020-5EC96-1DA0+L0G GE MIV 7RW600 and 7RW80 7RW EA00-0DA0 and 7RW8020-5EC96-1DA0+L0G GE NGV 7RW600 and 7RW80 7RW EA00-0DA0 and 7RW8020-5EC96-1DA0+L0G GE DFF 7RW600 and 7RW80 7RW EA00-0DA0 and 7RW8020-5EC96-1DA0+L0G GE MFF 7RW600 and 7RW80 7RW EA00-0DA0 and 7RW8020-5EC96-1DA0+L0G GE SFF 7RW600 and 7RW80 7RW EA00-0DA0 and 7RW8020-5EC96-1DA0+L0G *Siemens catalog numbers in Bold are the preferred equivalent model. Siemens Industry, Inc. SPEEDFAX 2011 Product Catalog 14-33
Perfect protection smallest space
www.siemens.com/energy/protection Perfect protection smallest space The SIPROTEC Compact device range redefines protection technology Answers for energy. SIPROTEC Compact is the ideal solution for almost
More informationSiemens AG All rights reserved.
SICAM Substation ti Automation ti Smart Substation Automation Panels DC PW SUPPLY DC PW SUPPLY GPS ARBITER SCALANCE X324 MONITOR RSG2100 RSG416 MONITOR GE UR T60 MUX GARD8000 7UT633 7SL87 7SL87 RACK PC
More informationCatalog Edition 6 siemens.com/protection
Selection Guide for and Catalog Edition 6 siemens.com/protection Overview of Siemens Protection Catalogs Documentation Selection guide for and Catalog Catalog Catalog Accessoires Catalog Catalogs Manuals
More informationSIPROTEC 5 V7.8 Protection, automation and monitoring for digital substations
SIPROTEC 5 V7.8 Protection, automation and monitoring for digital substations siemens.com/siprotec5 SIPROTEC 5 Table of content Introduction New functions of V7.8 SIPROTEC 5 - the core of Digital Substation
More informationThe complete application guide to specifying a Smart-Gear power distribution solution (PDS) E50001-F710-A123-V1-4A00. Answers for energy.
The complete application guide to specifying a Smart-Gear power distribution solution (PDS) E50001-F710-A123-V1-4A00 Answers for energy. Smart-Gear power distribution solution (PDS) Siemens, a world leader
More informationSubstation Automation Products. High impedance differential busbar protection REB650 Relion 650 series
Substation Automation Products High impedance differential busbar protection REB650 Relion 650 series One IED for a wide range of high impedance differential protection applications ABB introduces a new,
More informationSubstation Automation Products. Bay control REC670/650 Relion 670 and 650 series
Substation Automation Products Bay control REC670/650 Relion 670 and 650 series For optimized control and reliable operation of your switchyard The REC670 and REC650 Bay control IEDs (Intelligent Electronic
More informationSubstation Automation Products. Generator protection REG670/650 Relion 670 and 650 series
Substation Automation Products Generator protection REG670/650 Relion 670 and 650 series A new protection standard for your valuable assets Based on ABB s extensive experience, REG670 and REG650 IEDs (Intelligent
More informationProtection relays.
Protection relays www.vamp.fi Vamp Ltd Vamp Ltd, with a strong experience of designing devices, is an independent supplier of relays and monitoring equipment. The company has an established reputation
More informationSIPROTEC 5 Protection, automation, and monitoring
Products for modern energy grids SIPROTEC 5 Protection, automation, and monitoring Integrated Advanced Cyber Security siemens.com/siprotec SIPROTEC 5 Innovative, modular, and high quality Innovation focal
More informationPower Systems Communications Implementation of IEC61850 in a Substation Environment
Power Systems Communications Implementation of IEC61850 in a Substation Environment 26 October 2009 Reference VEE4700-01 Revision 0 Document Control Document ID: DOCUMENT1 Rev No Date Revision Details
More informationPerfect protection smallest space
www.siemens.com/siprotec Perfect protection smallest space The SIPROTEC Compact device range redefines protection technology Answers for infrastructure and cities. SIPROTEC Compact is the ideal solution
More informationSubstation Automation Products. Line differential protection RED670 Relion 670 series
Substation Automation Products Line differential protection RED670 Relion 670 series For maximum reliability of your power system The RED670 IED (Intelligent Electronic Device) is designed for protection,
More informationSIPROTEC 5 New features of V7.5
SIPROTEC 5 New features of V7.5 siemens.com/siprotec5 New Features for SIPROTEC 5 Release 7.50 Feeder Protection Ground Fault Detection (Pulse Detection, Harmonic Detection) Automatic Load Shedding Vector
More informationElectrical Integration with Smart Communication
Electrical Integration with Smart Communication New possibilities with Industrial Ethernet ABB Group September 24, 2009 Slide 1 Unified Integration Approach MES and Business Systems Knowledge Portals as
More informationSubstation Automation Products. Line distance protection REL670/650 Relion 670 and 650 series
Substation Automation Products Line distance protection REL670/650 Relion 670 and 650 series For maximum reliability of your power system REL670 and REL650 line distance protection IEDs (Intelligent Electronic
More informationSubstation Automation Products. Transformer protection RET670/650 Relion 670 and 650 series
Substation Automation Products Transformer protection RET670/650 Relion 670 and 650 series For reliable protection and control of all types of power transformers and reactors The RET670/650 IEDs (Intelligent
More informationSYMAP R Plug in Variants FI, MI, 87M, TI Technical data
SYMAP R Plug in Variants FI, MI, 87M, TI Technical data 1 Product overview SYMAP R (Retrofit) is a digital protection relay for use in medium and high-voltage power systems. Because of its integrated protection
More informationApplication Notes on Generator Protection Schemes
Application Notes on Generator Protection Schemes Single Line Diagram Examples 1. Introduction The application notes provide selected single line diagrams for the SIPROTEC 4 generator protection device
More informationRecloser Controller for feeder protection and automation siemens.com/distribution-automation
SIPROTEC 7SC80 Control Controller for feeder protection and automation siemens.com/distribution-automation SIPROTEC 7SC80 Control Designed for feeder automation applications This solution allows very fast
More informationNEO 3000 Substation System THE FAMILY OF EQUIPMENT DEDICATED FOR POWER UTILITIES. Energy Sector
THE FAMILY OF EQUIPMENT DEDICATED FOR POWER UTILITIES Introduction The supply of electrical energy occupies an important position in the life of modern society. Operation of commerce, industry, transport,
More informationSIPROTEC 7SC80 Feeder Protection and Automation Answers for infrastructure and cities.
www.siemens.com/protection SIPROTEC 7SC80 Feeder Protection and Automation Answers for infrastructure and cities. designed for feeder automation applications This solution allows very fast fault detection
More informationProduct Families and Positioning. Protection Portfolio
Product Families and Positioning Protection Portfolio siemens.com/energy-automation-products Agenda Protection Portfolio SIPROTEC 5 SIPROTEC Compact SIPROTEC 4 Reyrolle Page 2 Protection portfolio Fields
More informationBlueprint Data Center
Systems and Applications for Data Center Siemens Industy 1. Overview / Purpose In EM EA the datacenter market is seen as one of the fastest growing of the energy businesses. This blueprint is designed
More informationTWO-WINDING TRANSFORMER DIFFERENTIAL
E3-TR PROTECTION WITH AUTOMATIC VOLTAGE Because of the control, measuring and monitoring functions implemented, the IED can also be used as a bay control unit. The EuroCAP configuration tool, which is
More informationRELAYABLE POWER. AQ 200 series protection, control, measurement and monitoring IEDs
RELAYABLE POWER AQ 200 series protection, control, measurement and monitoring IEDs Contents AQ 200 series protection and control IEDs 3 AQ 200 benefits 3 AQ 200 protection functions 4 AQ 200 control and
More informationMaximize protection. Sepam series 10, 20, 40, 60, 80. Modular range of digital protection relays
Maximize protection Sepam series 10, 20, 40, 60, 80 Modular range of digital protection relays Fast Dependable Simple Increase energy availability 100% available energy Fast response Maximum dependability
More informationUPGRADE AND APPLICATION OF AUTOMATION SYSTEM IN T.S. 110/35/10 KV PETROVEC
ofpowersystems 2014 UPGRADE AND APPLICATION OF AUTOMATION SYSTEM IN T.S. 110/35/10 KV PETROVEC Vasilija Sarac 1, Dragan Minovski 2, Goran Cogelja Faculty of Electrical Engineering, University Goce Delcev,
More informationRELAYABLE POWER. AQ-200 series protection, control, measurement and monitoring IEDs
RELAYABLE POWER AQ-200 series protection, control, measurement and monitoring IEDs Contents AQ-200 series protection and control IEDs 3 AQ-200 benefits 3 Arcteq innovation: ultra-accurate measurement technology
More informationSiprotec 7ST61 / 7ST63
Siprotec / Numerical overhead contact line protection for AC traction power supply siemens.de/rail-electrification The numerical overhead contact line protection relay Siprotec / is a selective and quick
More informationPROTECTION, AUTOMATION & CONTROL
PROTECTION, AUTOMATION & CONTROL 1. DTIVA The members of the DTIVA product line are configured to protect and control the elements of not solidly grounded radial networks. Here the application of Petersen
More informationSIPROTEC 4 7SJ64 Multifunction Protection Relay with Synchronization
SIPROTEC 4 7SJ64 Multifunction Protection Relay with Synchronization Function overview Description The SIPROTEC 4 7SJ64 can be used as a protective control and monitoring relay for distribution feeders
More informationSIPROTEC 5 Application Note. Breaker-and-a-half solutions. SIP5-APN-002, Edition 2.
-and-a-half solutions SIP5-APN-002, Edition 2 www.siemens.com/protection SIPROTEC 5 Application Note -and-a half solutions SIP5-APN-002, Edition 2 -and-a-half solution Content 1 -and-a-half solutions 3
More informationSubstation automation products. MicroSCADA Pro for substation automation
Substation automation products for substation automation Perfect control anywhere, anytime is an investment for today and tomorrow. Start, for instance, with monitoring or gateway functionality and integrate
More informationPRC System Protection Coordination Supplementary Reference
PRC-001-2 System Protection Coordination Supplementary Reference Contents: Disclaimer... 2 Generator Protection Devices or Elements that May Require Coordination with Transmission or Distribution Protective
More informationRelion 615 series Line Differential Protection and Control RED615 Ver. 2.0 Technical Presentation
Relion 615 series Line Differential Protection and Control RED615 Ver. 2.0 Technical Presentation ABB Oy Distribution Automation July 1, 2009 1MRS756504 B Slide 1 Contents RED615 Technical Presentation
More informationT48 - Integrating Your Power and Automation Control Systems
T48 - Integrating Your Power and Automation Control Systems PUBLIC Copyright 2018 Rockwell Automation, Inc. All Rights Reserved. 1 Integrated Power & Automation The Evolution of End Client Requirements
More informationNumerical motor protection in medium voltage networks Motor Protection and Control REM620
Guideform Specification 1MRS758530 A Numerical motor protection in medium voltage networks Motor Protection and Control REM620 The configurable motor management relay is intended for protection, control,
More informationRELAYABLE POWER. AQ 200 series protection, control, measurement and monitoring IEDs
RELAYABLE POWER AQ 200 series protection, control, measurement and monitoring IEDs Contents AQ 200 series protection and control IEDs 3 AQ 200 benefits 3 AQ 200 protection functions 4 AQ 200 control and
More informationSACE Emax 2 Specification guide
SACE Emax 2 Specification guide Specification Number: 26 01 20.17 Product Name: LOW VOLTAGE POWER CIRCUIT BREAKERS PART 1 GENERAL NOTE: ( ) Indicates option or a selection is to be made for quantity or
More informationProduct Overview. Power Distribution Solutions. Answers for industry.
Product Overview Power Distribution Solutions Answers for industry. WinPM.Net Power Monitoring and Control Software Siemens web-enabled, open and flexible, reporting analysis tool for electrical engineers,
More informationGrid Automation Controller COM600 How it fits into the Smart Grid?
ABB Oy Distribution Automation Grid Automation Controller How it fits into the Smart Grid? May 27, 2014 Slide 1 1MRS756763 E Content Technical Presentation May 27, 2014 Slide 2 Description Grid Automation
More informationREL52002 Easergy P3U30, 4L, 4U, 16DI/8DO, Uaux: V, DI: V, RS-485
Characteristics Easergy P3U30, 4L, 4U, 16DI/8DO, Uaux: 48-230V, DI: 220-230V, RS-485 Main Range of product Product or component type Relay application Device short name [Us] rated supply voltage Type of
More informationGE Multilin 350 Feeder Protection Relay Specifications
GE Multilin 350 Feeder Protection Relay Specifications The feeder protection relay shall provide primary protection of medium voltage distribution feeders. The relay shall be equipped with the following
More informationABB Substation Automation Products Relion 670 series Ver. 2.0, IEC & ANSI What s new?
ABB Substation Automation Products Relion 670 series Ver. 2.0, IEC & ANSI What s new? Relion 670 series Ver. 2.0 Relion Product Family 605 610 615 620 630 650 670 Relion 670 series Ver. 2.0 Relion Product
More informationUtilization of IEC GOOSE messaging in protection applications in distribution network
9AKK106930A2259 Utilization of IEC 61850 GOOSE messaging in protection applications in distribution network Yogesh Bhamare Head-Product Management, Distribution Automation, ABB Limited, Vadodara, India
More informationSIMEAS P Power Meter POWER QUALITY Catalog SR
SIMEAS P Power Meter POWER QUALITY Catalog SR 10.3.1 2001 SIMEAS P Content Description 3 Screens 4to6 Configuration, Communication 6 Limit values 7 Parameters 7 Software 8 Typical terminal assignments
More informationContent REF615 Technical Presentation
Distribution Automation Relion 615 series Feeder Protection and Control Ver. 2.0 Technical Presentation March 30, 2010 1MRS756407 E Slide 1 Content Technical Presentation highlights March 30, 2010 Slide
More informationRelion 615 series Feeder Protection and Control REF615 Ver. 2.0 Technical Presentation
Relion 615 series Feeder Protection and Control REF615 Ver. 2.0 Technical Presentation Distribution Automation May 13, 2010 1MRS756407 E Slide 1 Content REF615 Technical Presentation highlights May 13,
More informationThe System for Power Automation
Basics 1 Tasks and solution The System for Automation The Tasks: Scalable system for Distributed process connection Process visualization Interface to control centre The Solution: Automation System PTD-SE-A2/
More informationSiemens Industrial Spares
s SIPROTEC 4 und SIPROTEC Compact State 12/16 Service Information Firmwareupdate Copyright Siemens AG 2015 Subject to technical alteration Siemens Aktiengesellschaft Siemens Industrial Spares 1 Copyright
More informationMiCOM P122C Time-Overcurrent Protection
Protection Relays 01 MiCOM P122C Time-Overcurrent Protection Customer Benefits 1A/5A software setting 4 function keys Compact unit for flush and wall-surface mounting Comprehensive measurements Disturbance
More informationOvercurrent and Arc Protection by Reyrolle Alexander Erokhin. 21, 2017 I Berlin
Overcurrent and Arc Protection by Reyrolle Alexander Erokhin VAR Partner Day September 20-21, 21, 2017 I Berlin Reyrolle Product Range by SIEMENS Challenges We Meet for our Customers Easy-to-use protection
More informationSEL Time-Domain Link (TiDL ) Technology
SEL Time-Domain Link (TiDL ) Technology The simple, fast, and secure digital secondary system solution Increase safety by removing high-energy cables from areas where personnel typically work. Reduce the
More informationSOLKOR-N (7SR18) Feeder Differential Protection. Make the ight choice! Choose EYROLLE Protection
SOLKO-N (7S18) Feeder Differential Protection CLASSIFICATION OF UNIT TYPE POTECTION Summation Transformer, Circulating Current Protection B B 3 1 1 O O 3 1 1 SUMMATION TANSFOME SUMMATION TANSFOME O - Operating
More informationRelion 630 series. Load-shedding controller PML630 High performing load-shedding solution for industrial and utility power networks
Relion 630 series Load-shedding controller PML630 High performing load-shedding solution for industrial and utility power networks Integrated load-shedding and protection solution The PML630 is a freely-configurable
More informationOverview and Application
IEC 61850 Overview and Application Who am I? Rich Hunt Market Development Leader GE Grid Solutions Over 25 years in the power systems industry At GE for 10 years (almost) Member of IEEE PSRC, U.S. Representative
More informationREL52001 Easergy P3U30, 4L, 4U, 16DI/8DO, Uaux: V, DI: V, 2 x RJ-45
Characteristics Easergy P3U30, 4L, 4U, 16DI/8DO, Uaux: 48-230V, DI: 220-230V, 2 x RJ-45 Main Range of product Product or component type Relay application Configuration type (Cortec) [Us] rated supply voltage
More informationType SDR reclosers plus controllers and type B-2 recloser bypass switch assembly usa.siemens.com/mediumvoltage
Overhead solutions Type SDR reclosers plus controllers and type B-2 recloser bypass switch assembly usa.siemens.com/mediumvoltage Overhead switching products Brochure Your outdoor overhead distribution
More informationSIPROTEC 5 Application Note
www.siemens.com/protection SIPROTEC 5 Application Note SIP5-APN-001: Properties and Functional Structure Answers for infrastructure and cities SIPROTEC 5 Properties SIPROTEC 5 - Application: SIP5-APN-001
More informationFeeder/ Motor Protection Relay VAMP 40
Feeder/ Motor Protection Relay Feeder/motor protection relay Main characteristics Complete protection Comprehensive selection of protection functions for distribution network overhead line feeders, cable
More informationINTRODUCTION. The PL-50 MO and PM-250 families represent the. PM-250-H: Horizontal box. PM-250-V: Vertical box
INTRODUCTION The PL-50 MO units are available in the next mechanical version: The PL-50 MO and PM-250 families represent the different solutions that Team Arteche offers for motor protection. Both families
More informationMP-4000 motor protection. Protection, control and diagnostics
MP-4000 motor protection Protection, control and diagnostics Multi-function motor protection Introducing Eaton s MP-4000 motor protection relay Eaton s MP-4000 motor protective relay combines all the features
More information1) IED Protection and Control Manager PCM 600 Tool (SEP-601) The following subjects will be studied:
1) IED Protection and Control Manager PCM 600 Tool (SEP-601) PCM 600 Introduction and Overview Application Configuration Tool (CAP 531) Signal Matrix Tool, SMT Graphical Display Editor, GDE Parameter Setting
More informationRelion 615 series Transformer Protection and Control RET615 Ver. 2.0 Technical Presentation
Relion 615 series Transformer Protection and Control RET615 Ver. 2.0 Technical Presentation Distribution Automation May 13, 2010 1MRS756901 A Slide 1 Content RET615 Technical Presentation highlights May
More informationNumerical Protective and Management Relays
Numerical Protective and Management Relays Presented at: The Institution of Engineers (India) Andaman and Nicobar State Centre Port Blair Dr. H. K. Verma Deputy Director and Professor of Electrical Engineering
More informationLecture 5 Substation Automation Systems. Course map
Lecture 5 Substation Automation Systems 1 Course map 2 1 Contents of the Lecture Part 1 Substation Automation Components Substation Automation Functions Communication within the Substation (Intro) Part
More informationSIPROTEC Compact Overcurrent Protection 7SJ81 for Low-Power CT and VT Applications
SIPROTEC Compact Overcurrent Protection SJ for Low-Power CT and VT Applications Overcurrent Protection SJ for Low-Power CT and VT Applications Page Description / Function overview / Applications / Application
More informationS o m e t h i n g b e t t e r t h a n p r o t e c t i v e r e l a y s. automation, control & communication
S o m e t h i n g b e t t e r t h a n p r o t e c t i v e r e l a y s IEDs with embedded protection, measurement, automation, control & communication digital processing multifunction Monitoring and metering
More informationSubstation Automation based on IEC Claes Rytoft ABB Power Systems
Substation Automation based on IEC 61850 Claes Rytoft ABB Power Systems BayNetworks Development of SA SA conventional MMI / Control Board NCC SA with interbay bus NCC SA with interbay & process bus NCC
More informationPeter Overgaauw Pascal Stijns 27 Oct 2016 EXPERION PKS CONTROLS ELECTRICAL SYSTEMS TOO!
Peter Overgaauw Pascal Stijns 27 Oct 2016 EXPERION PKS CONTROLS ELECTRICAL SYSTEMS TOO! Abstract Gain a basic understanding of an electrical control management system Exposure to a number of technology
More informationSIPROTEC 4 7SD61 Differential Protection Relay for Two Line Ends
Line Differential Protection / SD61 SIPROTEC 4 SD61 Differential Protection Relay for Two Line Ends Description The SD610 relay is a differential protection relay suitable for all types of applications
More informationSIPROTEC 5 Application Note
www.siemens.com/protection SIPROTEC 5 Application Note SIP5-APN-010: Answers for infrastructure and cities. SIPROTEC 5 - Application: SIP5-APN-010 SIPROTEC 5 Application Content 1 Application 3 1.1 Summary
More informationU lity network. system Q sys. Interconnected P sys. P load Q load. P gen Q gen. Generator network
SIL-G Feeder & Generator Protection Relay RC FLSH Main characteristics The SIL-G is a relay for primary distribution which can protect a feeder by means of current and voltage functions. It is also provided
More informationDan Murray, Siemens Energy Management Division
Design and Implementation of a Communication Network to Support Real-time Distribution Feeder Automation, SCADA Integration and Backhaul of Substation and Metering Data Dan Murray, Siemens Energy Management
More informationsiemens.com/poweracademy Enter the network of expertise A foundation for your success: The Siemens Power Academy TD course catalog
2012 siemens.com/poweracademy Enter the network of expertise A foundation for your success: The Siemens Power Academy TD course catalog Phone: +49 (911) 433 7415 E-mail: td.power-academy.energy@siemens.com
More informationAdvanced Line Differential Protection, Automation, and Control System. Combine subcycle line protection with traveling-wave fault locating
Advanced Line Differential Protection, Automation, and Control System Combine subcycle line protection with traveling-wave fault locating Subcycle differential and distance protection minimizes damage
More informationProtection, Automation, and Bay Control System. Advanced feeder protection and complete substation bay control in one economical system
SEL-451 Protection, Automation, and Bay Control System Advanced feeder protection and complete substation bay control in one economical system Customize distribution protection using multiple instantaneous,
More informationNext step in IEC 61850: Large applications and process bus applications José Roberto Moreira Rodrigues Clemens Hoga
Next step in IEC 61850: Large applications and process bus applications José Roberto Moreira Rodrigues Clemens Hoga Agenda Process bus application Large Applications IEC 61850 Overview *standardization
More informationProducts Portfolio. Pole mounted Vacuum Recloser
Products Portfolio Pole mounted Vacuum Recloser Efacec Switchgear Efacec Switchgear is a leading company in Portugal and a worldwide reference in the development of solutions for power generation, transmission,
More informationPackaged Solutions. Grid Solutions. Value Added Solutions for Protection, Control and Automation Applications. Flexible and Expandable
Grid Solutions Packaged Solutions Value Added Solutions for Protection, Control and Automation GE s Packaged Solutions provide fully integrated, modular solution sets comprising of engineering, design,
More informationFeeder Protection REF615 Ver Technical Presentation. ABB Oy Distribution Automation. Prashant Ganoo Regional Product Marketing Manager
ABB Oy Distribution Automation Prashant Ganoo Regional Product Marketing Manager Feeder Protection REF615 Ver. 1.1 Technical Presentation 9/26/2008-1 - 1MRS756407 C Self Introduction Prashant Ganoo B.E.(ELECT),
More informationProtection, Automation, and Control System. Combine subcycle line protection with complete substation bay control
Protection, Automation, and Control System Combine subcycle line protection with complete substation bay control Subcycle distance protection minimizes damage and expensive repairs on transmission lines.
More informationOne relay for safety and process continuity
Motor Management Relay One relay for safety and process continuity Improve safety at each motor control center (MCC) with secure, fast arc-flash detection. Use the enhanced thermal model for more precise
More informationSecure energy supply Energy Automation for Infrastructure and Functional Buildings
Secure energy supply Energy Automation for Infrastructure and Functional Buildings Power Transmission and Distribution Imagine the finals of the Soccer World Cup, with the score at 0:0 after overtime.
More informationEasily configurable HMI system for power automation siemens.com/sicam
SICAM SCC Easily configurable HMI system for power automation siemens.com/sicam Small components big prospects: Your SICAM SCC station control Power grid operation is becoming more and more dynamic. To
More informationLecture 6 Substation Automation Systems
Lecture 6 Substation Automation Systems 1 Course map 2 Contents of the Lecture Part 1 Substation Automation Components & Architectures Substation Automation Functions Communication within the Substation
More informationBus Bar Protection Relay B-PRO 4000
Bus Bar Protection Relay B-PRO 4000 Product Overview The IEC 61850 station bus embedded B-PRO 4000 relay provides complete bus and substation differential protection (low impedance) with CT saturation
More informationSIPROTEC 5 Devices Protection, Automation and Monitoring
www.siemens.com/siprotec SIPROTEC 5 Devices Protection, Automation and Monitoring Catalog SIPROTEC 5.0 Edition Answers for infrastructure and cities. Overview of documentation SIPROTEC 5 catalog Device
More informationA low-cost, economical solution for distribution feeder protection
SEL-351A Protection System A low-cost, economical solution for distribution feeder protection Achieve sensitive and secure fault detection using comprehensive protection functions. Track breaker status
More informationMiCOM P124. Self and Dual Powered Overcurrent Relays. Protection Relays
01 Self and Dual Powered Overcurrent Relays are numerical relays designed to offer complete overcurrent protection without requiring any external auxiliary supply. They can be applied to a wide variety
More informationDigital Substation Unrestricted Siemens AG 2017 siemens.com/digital-substation
Digital Substation A Substation Why Should We Make It Digital? Adopt new business models Time to operation Quality assurance Business agility Avoid outages Investment security Ensuring grid availability
More informationMicroSCADA Pro Substation automation applications.
G R I D AUTO M ATI O N PRO D U C T S Substation automation applications. ABB Oy Finland Power Grids Grid Automation P.O. Box 614 FI-65101 Vaasa, Finland Phone: +358 10 22 21999 (Customer Support Center)
More informationLowering Lifecycle Costs
Lowering Lifecycle Costs with Intelligent Motor Control Centers Standards Certification Education & Training Publishing Conferences & Exhibits Speakers: Presented and Authored by Jeff M. Miller, PE, ENV
More informationNon-conventional instrument transformers Advanced GIS substations with IEC LE process bus
Non-conventional instrument transformers Advanced GIS substations with IEC 61850-9-2LE process bus Content Towards the digital GIS substations Optimized substation design NCIT for gas-insulated switchgears
More informationAnswers for energy. SIPROTEC 5 the new benchmark for protection, automation, and monitoring of transmission grids
Answers for energy. SIPROTEC 5 the new benchmark for protection, automation, and monitoring of transmission grids 2 SIPROTEC 5 the new benchmark for protection, automation, and monitoring of your transmission
More informationIntegrated Energy Management System
PecStar iems Protect, Monitor, Control and Manage The PecStar iems Energy Management System provides a comprehensive software solution for the Protection, Monitoring, Control and Management of the electrical,
More informationProtection, Monitoring, and Control System for Distribution Substations ALARM HISTORY SYSTEM COMM. On-Line Documentation TRANSFORMER 12 MW
SEL Distribution Substation Protection and Automation System Protection, Monitoring, and Control System for Distribution Substations Data Sheet SYSTEM ONE-LINE RELAY TARGETS ALARM HISTORY SYSTEM COMM.
More informationNewCode. Comprehensive Motor Protection and Control Relay. Relay Field Input and Output LEDs. LED Fault Indicators
NewCode Comprehensive Motor Protection and Control Relay Relay Field Input and Output LEDs LED Fault Indicators Configurable Memory Module on a T-Bus IrDA and USB Connectors Profibus Address Indicator
More informationAlberto Carini, LPLS Italy, June 2013 MNS is The Intelligent MCC. ABB Group June 21, 2013 Slide 1
Alberto Carini, LPLS Italy, June 2013 MNS is The Intelligent MCC June 21, 2013 Slide 1 The MCC evolution Traditional MCC Intelligent relays MCC with integrated intelligence June 21, 2013 Slide 2 The intelligent
More information