Connnectors. B Series Connectors for rail vehicles Catalogue F160.en. More information here: schaltbau-gmbh.com

Size: px
Start display at page:

Download "Connnectors. B Series Connectors for rail vehicles Catalogue F160.en. More information here: schaltbau-gmbh.com"

Transcription

1 Connnectors B Series Connectors for rail vehicles Catalogue F0.en More information here: schaltbau-gmbh.com

2 Connectors for rail vehicles, The connectors, series B, have been designed especially for the demanding railcar environment. They are superbly suited for power and control circuits on road and rail vehicles alike. The power connectors can be used in applications up to 00 V respectively. By adding control contacts, protection circuits may be realised such as the interlocking circuit shown in the diagram below. Features Rugged design Universally usable connectors for power and control circuits Easy replacement of components Easy assembly resulting in short assembly times Mechanically locking connector Standards IEC 98: Connectors - Safety requirements and tests DIN EN 09: Degrees of protection provided by enclosures (IP Code) IEC 0-: Insulation coordination for equipment within low-voltage systems Quality and Safety Rail vehicles in good hands with Schaltbau connectors The development, manufacture and assembly of our products are subject to the quality management provisions of DIN EN ISO 900 and IRIS (International Railway Industry Standard). Continuous testing guarantees consistently high quality. Your benefit: Great performance at low operating costs. Maximum operating reliability and long lifetime of your rolling stock. Stock items, special variants Presented in this catalogue are only stock items that can be supplied in short delivery time. Special variants If you need a special variant feel free to contact us. Maybe the type of connector you are looking for is among our many special designs. If not, we can also supply customized designs. In this case, however, minimum order quantities apply. Subject to technical alterations

3 Application Interlocking circuit to protect personnel from contact with high voltages Power car Intermediate cars Last car Interconnected sockets in dummy receptacle Interconnected sockets in dummy receptacle Interconnected sockets in dummy receptacle Plug Receptacle Main contactor Plug Receptacle Plug Receptacle Plug Receptacle Plug Receptacle Plug Receptacle Interconnected sockets Interconnected sockets Interconnected sockets in dummy receptacle in dummy receptacle in dummy receptacle Plug contact Loop contact on receptacle Car body terminal Interconnected sockets in dummy receptacle Socket contact on receptacle Contact bridge on receptacle cover Intended use: The main contactor will apply voltage to the power circuit only when all covers are closed and all plugs have been inserted into their respective operating or dummy receptacles. At disengagement of a connector the control contacts (Pos. and ) interrupt the control circuit before the power contacts disconnect. Thus the main contactor interrupts power before the power contacts actually break their circuit. Components comprising the safety loop: plugs B ST with insert and additional control contacts (e.g. pin insert B E-P+PE+ /M /0) receptacles B Dx with contact bridge on cover, equipped with additional loop and control contacts (e.g. socket insert B E-S+PE+ /M /0) dummy receptacles B BD with contact insert B E-P /P with both control contacts (Pos. ) bridged Assembled as set Pre-assembled single and double ended connecting cables Single and double ended connecting cables Cables of different lengths and sizes Individual cables laid inside corrugated pipe Hybrid cables Pre-assembled to customer requirements Subject to technical alterations

4 Specifications, number of contacts max. +PE + pole / +PE + pole + 9 pole Inserts Dummy insert B E-P+PE+ /M B E-S+PE+ /M B E-P /P B E-P+9 /ML B E-S+9 /ML Contact arrangement Contact identification marked on insert: : Rear view : Front view 7 Contact bridge on receptacle cover Contacts brigded in socket insert D C B A Main contacts Max. rated current of individual contact Rated voltage PE contact* Terminal Control contacts Max. rated current of individual contact Rated voltage Crimp type 0.7 mm² mm².0 mm².0 mm² Loop contacts (socket insert only) Max. rated current of individual contact Rated voltage x 00 A 00 / 0 V V Screws M0x V Screw M0x x A 00 / 0 V C Screws Mx0 x A 0 / V Screws Mx0 x 00 A 0 / V W Screws M8x0 9 x 0 A 0 / V H Solder, mm² max. Contact resistance < 0 mω < 0 mω Insulation resistance > 00 MΩ > 00 MΩ Operating temperature ** -0 C C -0 C C Degree of protection when mated or locked (EN 09) IP IP Mechanical endurance (housing part ) (IEC 0-, test 9a) Materials Housing Colour Inserts, Seals Contacts Finish,000,000 Die-cast aluminium RAL 70 (blue grey) Thermoplastic / Thermoset Perbunan, Neoprene Copper, crimpable Ag Approvals * PE = protective earthing contact ** Operating temperatures exceeding C account for lower current ratings! Subject to technical alterations

5 Specifications, number of contacts max. 8 pole + PE 9 pole 9 pole + PE Inserts Dummy insert B E-8P+PE /M B E-8S+PE /M B E-9P /M B E-9S /M B E-9P+PE /Cxx B E-9S+PE /Cxx Contact arrangement Contact identification marked on insert: : Rear view : Front view ABCDEFGHKLMNPRSTU 8 7 Main contacts Max. rated current of individual contact Rated voltage PE contact* Terminal C Screws Mx0 Control contacts Max. rated current of individual contact Rated voltage Crimp type 0.7 mm² mm².0 mm².0 mm² 8 x A 0 V C Screws Mx0 9 x A 0 V C Screws Mx0 9 x A 00 / 0 V H Crimp (... /C,) (... /C,) Loop contacts (socket insert only) Max. rated current of individual contact Rated voltage) Contact resistance < 0 mω < 0 mω < 0 mω Insulation resistance > 00 MΩ > 00 MΩ > 00 MΩ Operating temperature ** -0 C C -0 C C -0 C C Degree of protection when mated or locked (EN 09) Mechanical endurance (housing part ) (IEC 0-, test 9a) IP IP IP,000,000,000 Materials Housing Colour Inserts, Seals Contacts Finish Die-cast aluminium RAL 70 (blue grey) Thermoplastic / Thermoset Perbunan, Neoprene Copper, crimpable Ag Die-cast aluminium RAL 70 (blue grey) Thermoplastic / Thermoset Perbunan, Neoprene Copper, crimpable Ag or Ni Approvals * PE = protective earthing contact ** Operating temperatures exceeding C account for lower current ratings! Subject to technical alterations

6 Housing part Housing part Contact Insert Overview :: B Series Plug B VS Pg8/- Ferrule (page 8) B VS Pg8/-8 Ferrule (page 8) B ST Pg8 Plug (page 8) B E-P+PE+ /M /0 (page ) B E-P+9 /ML (page ) B VS Pg/-9 Ferrule (page 8) B E-8P+PE /M (page ) B ST Pg Plug (page 8) B VS Pg/0- Ferrule (page 8) B E-9P /M (page ) B ST M0 Plug (page 9) B E-9P+PE /C, B E-9P+PE /C, including crimp contacts (page ) SHC-,0-Ag or SHC-,0-Ni Pin contact, crimp (page ) B E-9P+PE without crimp contacts (page ) B VS M8/-0 Cable gland (page 9) B ST M8 Plug (page 9) B ST M0 Plug (page 9)

7 7 Insert Contact Housing part Housing part B E-S+PE+ /M /0 (page ) B E-S+9 /ML (page ) B DL Pg9 Receptacle (page 0) B VD Pg8 Cover with Pg8 thread (page ) Overview :: B Series Receptacle B E-8S+PE /M (page ) B DL Receptacle long (page 0) B VD M0 Cover with M0 thread (page ) B E-9S /M (page ) B E-9S+PE /C, B E-9S+PE /C, including crimp contacts (page ) B DL R Receptacle (contact bridge on cover) (page 0) B E-9S+PE without crimp contacts (page ) BHC-,0-Ag or BHC-,0-Ni Socket contact, crimp (page ) B DK Receptacle short (page ) B E-P /P Dummy insert (page ) B BD Dummy receptacle (page )

8 8 B ST Pg, B ST Pg8 Plug for ferrule with Pg / Pg8 thread, housing Part Pg Ø ±0. Ø9 7 Figure A Pg Ø ±0. Ø9 Pg8 (Ø) Ø9 Ø80 0 Figure C Pg8 (Ø) Ø9 Ø80 ~ 98 M M Ø Pg Ø Pg8 Figure A Figure B Matching ferrule, available for different cable sizes, to be ordered separately: x B VS Pg/-9, cable diameter... 9 mm x B VS Pg/0-, cable diameter 0... mm x B VS Pg8/-, cable diameter... mm x B VS Pg8/-8, cable diameter... 8 mm B VS Pg/-9, B VS Pg/0-, B VS Pg8/-, B VS Pg8/-8 Ferrule with P,G thread housing Part 7 0 Figure B Figure D Ordering code Fig. Thread size Cable diameter [mm] B VS Pg/-9 A Pg... 9 B VS Pg/0- B Pg 0... Ferrule and cable clamp intended for use with plug B ST Pg. Ordering code Fig. Thread size Cable diameter [mm] B VS Pg8/- C Pg8... B VS Pg8/-8 D Pg Ferrule and cable clamp intended for use with plug B ST Pg8. Dimensions in mm / Subject to technical alterations

9 9 B ST M, B ST M8, B ST M0 Plug for ferrule with M0x. / M8x /M0x. thread, housing Part M8x Ø M M M ~ 98 Ø M0x. Ø M8x Ø M0x. Figure A Figure B Figure C Cable glands are only available for plugs B ST M8 (figure B). Cable glands for plugs B ST M0 (figure A) and B ST M0 (figure C) are not available. Please order separately. B VS M0/xx-xx Cable gland with metric thread, housing Part 80 Ordering code Thread size Cable diameter [mm] B VS M8/-0 M8x... 0 Cable glands B VS M8/-0 for plugs B ST M8 Cable glands M0x, for plugs B ST M0 and cable glands M0x, with metric thread for plugs B ST M0 are not available. Please order separately. Subject Dimensions to technical in mm / alterations Subject to technical alterations

10 0 B DL Pg9 Receptacle with 90 cable entry for ferrule with Pg9 thread, housing part 7 97 Gasket Screw-type blank cap M x 9 x Ø. 0 Bushing Pg9 Gasket and Pg9 threaded bushing supplied with the product. B DL Receptacle long, housing part 7 Gasket x 0 8 M x Ø. 9 Gasket supplied with the product. Please order cover B VD Pg8 or B VD M0 separately. B DK R Receptacle short with contact bridge on cover, housing part 7 Gasket x 0 8 M x Ø. 9 Gasket supplied with the product. Please order cover B VD Pg8 or B VD M0 separately. Dimensions in mm / Subject to technical alterations

11 B DK Receptacle short, housing part 7 Gasket x 0 8 M x Ø. 9 Gasket supplied with the product. Please order cover B VD Pg8 or B VD M0 separately. B BD Dummy receptacle, housing part 7 Gasket x 0 8 M x Ø. 9 Gasket supplied with the product B VD Pg8, B VD M0 Cover, housing part B VD Pg8 cover with Pg8 thread B VD M0 cover with M0 thread 7 Ø. 7 Ø () () (0) (0) x Pg8 x M0 Ø.8 Ø.8 Gasket, screws and washers supplied with the product Gasket, screws and washers supplied with the product Subject Dimensions to technical in mm / alterations Subject to technical alterations

12 Pin and socket inserts Inserts Accessories such as screws, lugs and crimp contacts are supplied with the product. Number of contacts max. + PE + pole / + PE + pole + 9 pole Inserts Dummy insert B E-P+PE+ /M B E-S+PE+ /M B E-S+PE+ /M B E-P /P B E-P+9 /ML B E-S+9 /ML Contact arrangement Contact bridge on receptacle cover Contact bridge on receptacle cover Contact bridge on receptacle cover Contact identification marked 7 on insert: : : Main contacts PE contact * Control contacts Rear view Front view Contacts brigded in socket insert Crimp type Stifteinsatz Contacts brigded in socket insert V Screws M0x V Screws M0x C Screws Mx0 9 Stifteinsatz 8 Contacts brigded in socket insert D C B A Stifteinsatz W Screws M8x0 C Screws Mx0 Number of contacts max. 8 pole + PE 9 pole Inserts Dummy insert B E-8P+PE /M B E-8S+PE /M B E-9P /M B E-9S /M Contact arrangement Contact identification marked on insert: : Rear view 0 9 : Front view Main contacts PE contact * Control contacts Crimp type Stifteinsatz C Screws Mx0 Stifteinsatz C Screws Mx0 Number of contacts max. Inserts Dummy insert Contact arrangement Contact identification marked on insert: : Rear view B E-9P+PE B E-9S+PE ABCDEFGHKLMNPRSTU : Front view pole + PE B E-9P+PE /C. or B E-9P+PE /C. B E-9S+PE /C. or B E-9S+PE /C. ABCDEFGHKLMNPRSTU 8 7 Stifteinsatz Main contacts PE contact * Control contacts for contacts size H ** (Crimp) ** Crimp type. mm² or. mm² * PE = protective earthing contact ** Insert without contacts, please order separetely *** Contacts included in delivery Stifteinsatz H *** Crimp. mm² or. mm² Dimensions in mm / Subject to technical alterations

13 Contacts Crimp (pin/socket), for B E-9P+PE und B E-9S+PE only Contacts SHC-x, BHC-x Crimp contacts (pin/socket): Ø Identification Ø7. Wire gauge Ø Identification Ø7. Wire gauge L L Pin contact Ordering code L Identification SHC-.0-Ag. grooves SHC-.0-Ni. grooves Socket contact Ordering code L Identification BHC-.0-Ag. grooves BHC-.0-Ni. grooves Specification Wire gauge* Rated current. mm² A. mm² 7. A * For AWG sizes refer to the conversion table on our home page AWZ-x Extraction tool CWZ-00- Crimp tool Crimp tool AWZ-C/H Extraction tool for contacts Type C and Type H CWZ-00- Crimp tool for wire gauges* ranging from 0,...,00 mm² (Figure reduced in scale) (Figure reduced in scale) Mounting template Mounting template for all receptacles: B DL Pg9 Receptacle for Pg9 threaded ferrule, locked B DL Receptacle long B DL R Receptacle short with contact bridge in cover B DK Receptacle short R0 B BD Dummy receptacle 8 9 Ø. Subject Dimensions to technical in mm / alterations Subject to technical alterations

14 Assembly Receptacle B DL R with insert B E-S+PE+ /M / 0 : front view Receptacle (Sectional view) Mounting x M screw in housing Lug 70 mm² lugs 70 mm² for terminal M0 loosely enclosed. Terminal type: solder. Slide shrink fitting tubings over all lugs! Flat rubber gasket B E-S+PE+ /M / 0 Loop contact Contact travel approx. mm : rear view Connecting lead H07-K mm² pre-assembled Insulator on cover Lug 0 mm² for connecting protective earth conductor to housing Lug mm² terminal M Terminal type: solder/crimp PE conductor connected to housing Hex screw M x 8 Auxiliary contact Terminal M Main contact Terminal M0 Contact bridge Loop contact Contact travel approx. mm Receptacle with contact bridge on cover B DL R Pre-assembled cables Signle and double ended connector cables Do you prefer a pre-assembled connector? Do not hesitate to contact us. We supply on request receptacles and plugs assembled complete with cables or wires to suit the customer s specific requirements. Schaltbau offers a host of cable lengths and wire gauges to suit your application and guarantees a constant high quality of the assembled connectors. Double ended connector cable L L Single ended connector cable L L Pre-assembled plugs Single and double ended connecting cables Cables of different lengths and sizes Individual cables laid inside corrugated pipe Hybrid cables Pre-assembled to customer requirements Dimensions in mm / Subject to technical alterations

15 Installation and safety instructions The UIC Series inter-car jumpers dealt with in this catalogue are intended for use with low-voltage systems and special installations. They are designed and tested in compliance with the generally recognised state of the art. However, the improper use, operation, handling, maintenance of or tampering with electric equipment can cause serious or fatal injury to the user or others, and the appliance or other property can be damaged. Due to our continuous improvement programme, the design of our products can be modified at any time. So some features may differ from the descriptions, specifications and drawings in the catalogue. You can download the latest update of the catalogue at schaltbau.info/downloaden. The updated catalogue renders the previous issue invalid. Electrical hazards: Any exposure to the connector s live parts. Risk of electrical shock! Observe all applicable national provisions, all safety, accident prevention and environmental regulations as well as the recognized technical rules for safe and proper working. Only authorized and trained personnel are allowed to plan and carry out all mechanical and electrical installations, transport, commissioning, as well as maintenance and repair work. This applies to the observation of the general installation and safety regulations for low-voltage systems as well as the proper use of tools approved for this purpose. Electric equipment requires protection from moisture and dust during installation, operation and storage. Electrical hazards: Any exposure to the connector s live parts. Risk of electrical shock! Work on electric equipment may only be performed by a qualified electrician or trained personnel working under the direction and supervision of a qualified electrician according to the applicable rules of electrical engineering. Observe all applicable national provisions, all safety, accident prevention and environmental regulations as well as the recognized technical rules for safe and proper working. Carry out regular inspections of all protection and safety devices to see if they work properly. Work on electric equipment may only be performed by a qualified electrician or trained personnel working under the direction and supervision of a qualified electrician according to the applicable rules of electrical engineering. The connectors supply power and signals. They are intended for plug-in and detachable connections of components, devices and systems only. In order to comply with IEC 98 make sure that always the live side of the connector no matter whether plug or receptacle is fitted with socket contacts. Crimp connections have to be manufactured according to IEC 0- Solderless Connections. Make sure that there is no undue strain, pressure, flexing and torsion on the cable connection. For optimum protection of the cable connection make sure the connector is supplied with a strain relief. According to IEC 98 connectors used as intended must not be engaged or disengaged when live or under load. Crimp connections have to be manufactured according to IEC 0- Solderless Connections. When disengaging a connector, pull the plug and never the cable. A connector that does not engage easily requires special attention: Check for the correct orientation, pollution or if contacts got bent. Remedy the cause without delay. Never use force! The connector should always engage easily. In order to meet the requirements of the protection class and to protect the connectors against the entry of dirt or moisture, make sure that, when not mated, the plug is always inserted into a dummy receptacle the hinged lid of receptacles is closed, according to its intended use Use the connector only according to its intended use. Replace or repair damaged parts exclusively with original parts. Any other usage of or tampering with the connector is considered contrary to its intended use. No liability is assumed for damages and accidents caused due to non-compliance with the instructions or improper use of the connector. The connectors are constructed for specific ambient conditions. Operate the connectors only under the ambient conditions, like temperature ranges and IP protection classes as defined in our catalogue on page Specifications. Visual inspections Be sure to make visual inspections regularly. Improper handling of the connector, e.g. when hitting the floor with some impact, can result in breakage, visible cracks and deformation. Defective and/or leaky parts must be replaced instantaneously! Subject Dimensions to technical in mm / alterations Subject to technical alterations

16 Schaltbau GmbH For detailed information on our products and services visit our website or give us a call! with compliments: Schaltbau GmbH Hollerithstrasse 889 Munich Germany Phone Fax Internet contact@schaltbau.de RoHS 0//EC Schaltbau GmbH manufactures in compliance with RoHS. The production facilities of Schaltbau GmbH have been IRIS certified since 008. Quality you can count on Schaltbau Certified to DIN EN ISO 00 since 00. For the most recent certificate visit our website. Quality you can count on Schaltbau Certified to DIN EN ISO 900 since 99. For the most recent certificate visit our website. Electrical Components and Systems for Railway Engineering and Industrial Applications Connectors Connectors manufactured to industry standards Connectors to suit the special requirements of communications engineering (MIL connectors) Charging connectors for battery-powered machines and systems Connectors for railway engineering, including UIC connectors Special connectors to suit customer requirements Snap-action switches Snap-action switches with positive opening operation Snap-action switches with self-cleaning contacts Enabling switches Special switches to suit customer requirements Contactors Single and multi-pole DC contactors High-voltage AC/DC contactors Contactors for battery powered vehicles and power supplies Contactors for railway applications Terminal bolts and fuse holders DC emergency disconnect switches Special contactors to suit customer requirements Electrics for rolling stock Equipment for driver's cab Equipment for passenger use High-voltage switchgear High-voltage heaters High-voltage roof equipment Equipment for electric brakes Design and engineering of train electrics to customer requirements F89/80/0 Printed in Germany Subject to change! For updated product information visit

Connect - Contact - Control. Connectors for rail vehicles Series B. 94x122. F 160.en

Connect - Contact - Control. Connectors for rail vehicles Series B. 94x122. F 160.en onnect - ontact - ontrol onnectors for rail vehicles 9x 0 8 9 8 F 0.en onnectors for rail vehicles, The connectors, series B, have been designed especially for the demanding railcar environment. They are

More information

Connect - Contact - Control. Connectors according to UIC VE EP Series. F 121.en

Connect - Contact - Control. Connectors according to UIC VE EP Series. F 121.en Connect - Contact - Control Connectors according to UIC 541-5 VE 123 F 121.en 2 Connector to UIC standard 541-5 VE, The connector is designed in accordance with the specifications of the international

More information

Connectors. UIC Series Inter-car jumpers to UIC 558 VE Catalogue F120.en. More information at: schaltbau-gmbh.com

Connectors. UIC Series Inter-car jumpers to UIC 558 VE Catalogue F120.en. More information at: schaltbau-gmbh.com 1 Connectors UIC Series Inter-car jumpers to UIC 558 VE Catalogue F120.en More information at: schaltbau-gmbh.com 2 UIC Series Inter-car jumpers to UIC 558 VE Schaltbau jumpers for inter-car connections

More information

Connect - Contact - Control. Multifunctional adapters for LV160 and LV320 Series charging connectors A 841.en

Connect - Contact - Control. Multifunctional adapters for LV160 and LV320 Series charging connectors A 841.en Connect - Contact - Control Multifunctional adapters for LV160 and LV320 Series charging connectors 110 37 61 90.5 A 841.en 2 Multifunctional adapters for LV160 and LV320 Series charging connectors Modular

More information

Connect - Contact - Control. Connectors. SB Series Circular connectors for special applications Manual A30-M.en

Connect - Contact - Control. Connectors. SB Series Circular connectors for special applications Manual A30-M.en Connect - Contact - Control 1 Connectors SB Series Circular connectors for special applications Manual A30-M.en Contents 1. Important Basic Information...3 1.1 Legal Notes...3 1.2 Conventions for this

More information

Connector series UIC 558 VE R115. F 120.en

Connector series UIC 558 VE R115. F 120.en Connector series UIC 558 VE R115 4 52 F 0.en UIC 558 VE series connector The connector complies with the requirements of UIC 558 VE (up to 1994: UIC 58 VE). It connects lines used for the: remote control

More information

Connect - Contact - Control. Connectors. UIC Series Inter-car jumpers to UIC 558 VE Manual F120.en

Connect - Contact - Control. Connectors. UIC Series Inter-car jumpers to UIC 558 VE Manual F120.en Connect - Contact - Control 1 Connectors UIC Series Inter-car jumpers to UIC 558 VE Manual F120.en Inhalt 1. Important Basic Information... 3 1.1 Legal Notes... 3 1.2 Conventions for this Installation

More information

Operating instructions Hinge safety switch TV.S 335 TV.S About this document. Content

Operating instructions Hinge safety switch TV.S 335 TV.S About this document. Content 1. About this document Operating instructions.............pages 1 to 6 Original 1.1 Function This operating instructions manual provides all the information you need for the mounting, set-up and commissioning

More information

Operating Manual / IEC. Explosion-Proofed Junction Boxes, Polyester. Wallücker Bahndamm 7 DE Kirchlengern

Operating Manual / IEC. Explosion-Proofed Junction Boxes, Polyester. Wallücker Bahndamm 7 DE Kirchlengern Operating Manual / IEC Explosion-Proofed Junction Boxes, Polyester Wallücker Bahndamm 7 DE- 32278 Kirchlengern Tel.: +49 5223 49107-0 Fax: +49 5223 49107-28 info@multi-box.com www.multi-box.com Contents

More information

Operating instructions Enabling switch (handle switch) ZSD5 ZSD6. 1. About this document. Content. 7 Appendix 7.1 Wiring example...

Operating instructions Enabling switch (handle switch) ZSD5 ZSD6. 1. About this document. Content. 7 Appendix 7.1 Wiring example... 7 ppendix 7.1 Wiring example...5 8 Declaration of conformity 8.1 EC Declaration of conformity...6 Operating instructions.............pages 1 to 6 Translation of the original operating instructions x.000

More information

Han-Brid. Contents Han-Brid Features Han-Brid Data interfaces Han-Brid Overview Han-Brid Cu

Han-Brid. Contents Han-Brid Features Han-Brid Data interfaces Han-Brid Overview Han-Brid Cu Contents Page Features... 19.02 Data interfaces... 19.03 Overview... 19.04 Cu... 19.06 F.O.... 19.08 Quintax 3 A... 19.10 RJ45 C... 19.12 USB / FireWire... 19.14 Han 4 A SC... 19.16 Hoods/Housings... 19.18

More information

Operating instructions Enabling switch (handle switch) ZSD5 ZSD6. 1. About this document. Content. 7 Appendix 7.1 Wiring example...

Operating instructions Enabling switch (handle switch) ZSD5 ZSD6. 1. About this document. Content. 7 Appendix 7.1 Wiring example... 7 ppendix 7.1 Wiring example...5 8 EU Declaration of conformity Operating instructions.............pages 1 to 6 Original x.000 / Januar 2017 / v.. - 101196069- / F / 2017-01-12 / E-Nr. 5813 Content 1 bout

More information

Connect - Contact - Control. High Voltage Contactors. F 170e

Connect - Contact - Control. High Voltage Contactors. F 170e Connect - Contact - Control High Voltage Contactors F 170e 2 Contents Page 1.0. Application...3 2.0. Power Rating...3 3.0. Device Data...4 3.1. Electronic Contactor Type ZH 767E / 767F... 4 3.2. Contactor

More information

Vandal-proof latching action switch MSM LA

Vandal-proof latching action switch MSM LA Product Manual Vandal-proof latching action switch MSM LA CONTENTS 1 PRODUCT DESCRIPTION... 2 2 TECHNICAL DATA AND DIMENSIONAL DRAWINGS... 2 2.1 Technical Data... 2 2.2 Dimensional Drawings... 5 2.3 Hole

More information

Electromotoric actuators Torques up to 60 Nm Running times ¹) s. ¹) Predefined by the basic unit (LMV5...)

Electromotoric actuators Torques up to 60 Nm Running times ¹) s. ¹) Predefined by the basic unit (LMV5...) 7 818 Actuators SQM9... Electromotoric actuators Torques up to 60 Nm Running times ¹) 30...120 s ¹) Predefined by the basic unit (LMV5...) The SQM9... and this Data Sheet are intended for use by OEMs which

More information

D-Sub SEaled subminiature D connectors, 2.54 mm pitch

D-Sub SEaled subminiature D connectors, 2.54 mm pitch SE D-Sub SEaled subminiature D connectors, 2.54 mm pitch Page Technical characteristics.......................................... 02 IP 67 versions with turned solder cups......... 04 IP 67 versions with

More information

V Schaltbau LV Euro connectors

V Schaltbau LV Euro connectors 1 Schaltbau LV Euro connectors High Power Connectors LVHPC Series More Power for Faster Charging With the new LVHPC Series Schaltbau charging connectors satisfy the requirements of DIN VDE 063589 for a

More information

PTB 01 ATEX 2064 U, IECEx PTB U. Example / Beispiel / Exemple: Type Operating Instructions

PTB 01 ATEX 2064 U, IECEx PTB U. Example / Beispiel / Exemple: Type Operating Instructions , Equipment protection fuse with Ex mb II C Gb approval Geräteschutzsicherung mit Zulassung Ex mb II C Gb Fusible de protection d appareil avec homologation Ex mb II C Gb Example / Beispiel / Exemple:

More information

Operating and Installation Manual. EASYLAB Expansion modules Type EM-TRF for 230 V AC mains voltage

Operating and Installation Manual. EASYLAB Expansion modules Type EM-TRF for 230 V AC mains voltage Operating and Installation Manual EASYLAB Expansion modules Type EM-TRF for 230 V AC mains voltage Type EM-TRF-USV for 230 V AC mains voltage; provides uninterruptible power supply (UPS) The art of handling

More information

Power supply unit NG3-16ib

Power supply unit NG3-16ib Ordering Data Designation Type Item no. Power supply unit NG3-16ib (42 V AC / ) 371 008 31 AX Power supply unit NG3-16ib (230 V AC / ) 371 008 32 AX Power supply unit NG3-16ib (100 V AC / ) 371 008 34

More information

HST -S1 Switching element (Translation of Original Manual)

HST -S1 Switching element (Translation of Original Manual) Installation and Operating Manual for Components HST -S1 Switching element (Translation of Original Manual) HST-S1 Ident.-No.: 10222 HST-S1 Ident.-No.: 10228 HST-S1 Ident.-No.: 10223 HST-S1 Ident.-No.:

More information

SMS 3xxx/SMS 4xxx Safety switch with separate actuator

SMS 3xxx/SMS 4xxx Safety switch with separate actuator Operating Instructions (Translation of the original instructions) SMS 3xxx/SMS 4xxx Safety switch with separate actuator SMS 3xxx SMS 4xxx Wieland Electric GmbH Brennerstraße 10-14 D-96052 Bamberg Tel.

More information

HST -M2 Switching element with locking mechanism (Translation of Original Manual)

HST -M2 Switching element with locking mechanism (Translation of Original Manual) Installation and Operating Manual for Components HST -M2 Switching element with locking mechanism (Translation of Original Manual) HST-M2 Ident.-No.: 10214 HST-M2 Ident.-No.: 10626 HST-M2 Ident.-No.: 10218

More information

Brochure Snap-Action Switches

Brochure Snap-Action Switches 2 Brochure Snap-Action Switches Switches for safety-related applications with robust and precise switch mechanism and positive opening operation More information here: schaltbau-gmbh.com WE GUARANTEE DOUBLE

More information

Operating voltages up to 40 kvdc Operating current up to 30 Amps Advanced contact technology Silver plated and gold plated contacts available High

Operating voltages up to 40 kvdc Operating current up to 30 Amps Advanced contact technology Silver plated and gold plated contacts available High Operating voltages up to 40 kvdc Operating current up to 30 Amps Advanced contact technology Silver plated and contacts available High performance insulation material General characteristics and technical

More information

Better all-round. DataVoice Circular connectors STX M12x1 IP67 Connector series for industrial applications. PoE+ 10 GBE. coded.

Better all-round. DataVoice Circular connectors STX M12x1 IP67 Connector series for industrial applications. PoE+ 10 GBE. coded. Better all-round. X coded D coded 10 GBE PoE+ DataVoice Circular connectors STX M12x1 IP67 Connector series for industrial applications STX M12x1 IP67 connector series With the STX M12x1 IP67 connector

More information

Safety switches for hinged doors

Safety switches for hinged doors C Safety switches for hinged doors Selection diagram FR FM FX FZ FK 18 7 9 snap action overlapped CONTACT BLOCKS 21 NC 1NO+ CONDUIT ENTRIES Threaded conduit entries (standard) With cable gland assembled

More information

HST -M1 Switching element with locking mechanism (Translation of Original Manual)

HST -M1 Switching element with locking mechanism (Translation of Original Manual) Installation and Operating Manual for Components HST -M1 Switching element with locking mechanism (Translation of Original Manual) HST-M1 Ident. No.: 10213 HST-M1 Ident. No.: 10219 HST-M1, pictured Ident.

More information

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x 1. Description The supply module was developed specially for direct mounting in hazardous areas in Zone 1 and 21 and is ATEX-certified. The supply module is a permanently installed piece of electrical

More information

EPIC Circular Connectors CIRCON M23 Series

EPIC Circular Connectors CIRCON M23 Series The M3 connectors have many inherent features which offer application advantages and provide significant benefits for the customer. These features make it one of the most application friendly connectors

More information

SIWAREX JB Aluminum Housing. Instruction Manual Edition 03/2006

SIWAREX JB Aluminum Housing. Instruction Manual Edition 03/2006 s SIWAREX JB Aluminum Housing Instruction Manual Edition 03/2006 Table of Contents Table of Contents... 2 Warning and Safety Terms... 3 General... 4 1 Technical Description... 5 1.1 Area of Application...

More information

Han R 23. Circular Connector. Certified acc. to DIN EN ISO 9001 in design/ development, production, installation and servicing.

Han R 23. Circular Connector. Certified acc. to DIN EN ISO 9001 in design/ development, production, installation and servicing. Circular Connector Certified acc to DIN EN ISO 9001 in design/ development, production, installation and servicing Data Sheet 0039-4 Circular Connectors Features Size R 23 Outer diameter 26 mm High contact

More information

Operating Instructions

Operating Instructions TPS S1 AC in DC out Translation of the original instructions TPS 110-400 Mains pack Operating Instructions PT 0199 BEN/C (1010) EN Table of contents Table of contents 1 About this manual...............................................

More information

Operating instructions Safety-monitoring module AES 1235 AES About this document. Content

Operating instructions Safety-monitoring module AES 1235 AES About this document. Content 8 Appendix 8.1 Wiring examples...3 8.2 Integral System Diagnostics (ISD)....4 9 EU Declaration of conformity Operating instructions.............pages 1 to 6 Original x.000 / 11.2017 / v.a. - 101172890-

More information

VMEbus systems System description Technical characteristics System description

VMEbus systems System description Technical characteristics System description Directory chapter 06 / inverse Page VMEbus systems................................................ 06.02 System description.............................................. 06.03 Technical characteristics..........................................

More information

Emergency Luminaire for Fluorescent Lamps Series EXLUX 6009

Emergency Luminaire for Fluorescent Lamps Series EXLUX 6009 > As wall, ceiling and pendant light fitting or pole mounted light fitting > Version with 2 lamps: 18 W and 36 W > Central locking > All-pole disconnection via N/C switch when opening light fitting or

More information

IF-80x Outdoor Terminal

IF-80x Outdoor Terminal 95-10330_IF-800 V2016-10-20 Outdoor Terminal IF-80x Outdoor Terminal 1 IF-800 Outdoor / IF-801 We are pleased that you have decided to use a terminal of the IF-80x series for recording access data. Scope

More information

Providing flexible power supply and signal connection there, where it is needed even in hazardous areas for the Zones 1and 2.

Providing flexible power supply and signal connection there, where it is needed even in hazardous areas for the Zones 1and 2. e X L i n k exlink 7-pole / 6-pole + PE for Zone 1 and Zone 21 Providing flexible power supply and signal connection there, where it is needed even in hazardous areas for the Zones 1and 2. The exlink 7

More information

Operation Manual. Capacitor Boxes adjustable 80 A / 125 A Track, 2,04 μf to 8 μf. Order Number

Operation Manual. Capacitor Boxes adjustable 80 A / 125 A Track, 2,04 μf to 8 μf. Order Number Order Number 91008-210-3088444 Capacitor Box 80 A adjustable 2,04 μf to 2,72 μf 91008-210-3088445 Capacitor Box 80 A adjustable 3 μf to 8 μf 91012-210-3101180 Capacitor Box 125 A adjustable 2,04 μf to

More information

Operating instructions Safety-monitoring module SE-304 C. 1. About this document. Content

Operating instructions Safety-monitoring module SE-304 C. 1. About this document. Content 6 Disassembly and disposal 6.1 Disassembly....4 6.2 Disposal...4 Operating instructions.............pages 1 to 6 Original 7 Appendix 7.1 EU Declaration of conformity...5 7.2 Mounting and inspection protocol...6

More information

Operating Manual -ENGLISH- Page 1 KWG-ISO

Operating Manual -ENGLISH- Page 1 KWG-ISO Page 1 KWG-ISO Operating manual English- Status May 2013 Page 2 Manufacturer address KW-Generator GmbH & Co.KG Bänglesäcker 24 73527 Schwäbisch-Gmünd / Lindach Phone: +49 (0) 7171 104 17 0 Fax: +49 (0)

More information

SolConeX extra-low voltage flange socket

SolConeX extra-low voltage flange socket SolConeX extra-low voltage flange socket Operating instructions Additional languages www.stahl-ex.com Contents 1 General Information...3 1.1 Manufacturer...3 1.2 Information regarding the operating instructions...3

More information

Installation manual plugs and connectors with screw connection (16/32 A)

Installation manual plugs and connectors with screw connection (16/32 A) EN Installation manual plugs and connectors with screw connection (16/32 60003213 Issue 04.2016 2016-04-01 Table of contents 1 About this manual 3 1.1 Structure of the warnings 3 1.2 Symbols used 4 1.3

More information

Standard Buccaneer BUCCANEER FOR POWER

Standard Buccaneer BUCCANEER FOR POWER IP8 rating tested at 1.05kg/sq cm (15lb/sq in) 10m depth for weeks and.8kg/sq cm (10lb/sq in) 100m depth for hours IPK, Tested in accordance with DIN 0050/Part IPkk Water and dustproof to IP8 when mated,,,,,,

More information

B63/ NS MS. EtherNet/IP LINK

B63/ NS MS. EtherNet/IP LINK 3 609 929 B63/ IMenip 2008-09 NS MS EtherNet/IP LINK 3 609 929 B63/2008-09 IMenip Bosch Rexroth AG 15/76 Table of Contents About this document................. 16 General safety instructions............

More information

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS SINAMICS G130 Operating Instructions 03/2013 SINAMICS s Safety information 1 General information 2 SINAMICS SINAMICS G130 Mechanical installation 3 Electrical installation 4 Technical specifications 5

More information

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1 Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.keithley.com Model 2460-KIT Screw Terminal Connector Kit Description The Model 2460-KIT Screw Terminal Connector Kit

More information

HARTING. Interface Connectors. People Power Partnership

HARTING. Interface Connectors. People Power Partnership 11 5 HARTING Interface Connectors People Power Partnership Directory chapter 00 Modular metric high speed connectors, 2.0 mm pitch Page connector system general information......................... 00.04

More information

Operating and mounting instructions

Operating and mounting instructions General Usage IPAS DALI Gateways bring together the crossfunctional KNX installation bus and the lighting control specific DALI-Bus (IEC 60929). Lights with cost-effective, digital DALI ECGs can therefore

More information

CONNECTOR AND RECEPTACLE WIRE/CABLE ASSEMBLY INSTRUCTIONS

CONNECTOR AND RECEPTACLE WIRE/CABLE ASSEMBLY INSTRUCTIONS CONNECTOR AND RECEPTACLE WIRE/CABLE ASSEMBLY INSTRUCTIONS Throughout this manual, look for this symbol. It means BE ALERT YOUR SAFETY IS INVOLVED. If you do not follow these safety instructions, personal

More information

Operating instructions Door handle switch BNS-B About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal...

Operating instructions Door handle switch BNS-B About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal... 6 Disassembly and disposal 6.1 Disassembly....6 6.2 Disposal...6 7 EU Declaration of conformity Operating instructions.............pages 1 to 8 Original x.000 / 09.2017 / v.a. - 101178533- / I / 2017-08-31

More information

Supplementary instructions. Plug connector Harting HAN 7D. For point level sensors. Document ID: 34456

Supplementary instructions. Plug connector Harting HAN 7D. For point level sensors. Document ID: 34456 Supplementary instructions Plug connector Harting HAN 7D For point level sensors Document ID: 446 Contents Contents For your safety.... Appropriate use.... General safety instructions.... Safety instructions

More information

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005 Product and Applications Description Application Programs The application programs of the dimmer UP 525/01 consist of two elements: the actuating and the sensor program element. The tasks actuating program

More information

PTB 01 ATEX Example / Beispiel / Exemple. Type Operating Instructions

PTB 01 ATEX Example / Beispiel / Exemple. Type Operating Instructions Device with II 2G EX i approval Geräte mit II 2G EX i Zulassung Appareils avec mode de protection II 2G EX i Example / Beispiel / Exemple Type 6106 Operating Instructions Bedienungsanleitung Manuel d utilisation

More information

ODU MAC LC. Modular Attachable Connector System

ODU MAC LC. Modular Attachable Connector System Catalogue No. 1004 LC-a ODU MAC LC Modular Attachable Connector System ODU Steckverbindungssysteme GmbH & Co. KG, Pregelstr. 11, 84453 Mühldorf a. Inn, Germany Phone: +49/ 86 31/61 56-0, Fax: +49/ 86 31/61

More information

Han PCB termination. Han-Fast Lock PCB adapter for Han DD PCB adapter for Han DDD module

Han PCB termination. Han-Fast Lock PCB adapter for Han DD PCB adapter for Han DDD module Han termination Contents Page Han-Fast Lock... 20.11 adapter for Han DD... 20.13 adapter for Han DDD module... 20.16 adapter for Han 40 A Axial module... 20.18 adapter for Han E... 20.20 adapter for Han

More information

SolConeX Wall-Mounted Socket, 16 A

SolConeX Wall-Mounted Socket, 16 A SolConeX Wall-Mounted Socket, 16 A Operating instructions Additional languages www.stahl-ex.com General Information Contents 1 General Information...2 1.1 Manufacturer...2 1.2 Information Regarding the

More information

Operating instructions Safety-monitoring module AES 1235 AES About this document. Content

Operating instructions Safety-monitoring module AES 1235 AES About this document. Content 1. About this document DE Betriebsanleitung...............Seiten 1 bis 6 Übersetzung der Originalbetriebsanleitung 1.1 Function This operating instructions manual provides all the information you need

More information

Product manual plug, sockets and coupler 16 A.- Z0251

Product manual plug, sockets and coupler 16 A.- Z0251 Product manual plug, sockets and coupler 16 A.- Z0251 INDEX ELEKTRO BV Harregatplein 15 3214 VP Zuidland Netherlands T. +31(0)181 452120 http/www.indexelektro.nl email info@indexelektro.nl Purpose of these

More information

Vibration Sensor Type 640

Vibration Sensor Type 640 Vibration Sensor Type 640 Standard Zone-1-21 Zone-2-22 Instruction Manual English Instruction Manual Vibration Sensor Type 640 Standard Zone-1-21 Zone-2-22 Edition: 12.04.10 Attention! Before Start-Up

More information

Quick Selection Guide

Quick Selection Guide Quick Selection Guide Signal Connectors M23 Coupling ayonet Coupling CONINVERS Edition 03/02 Signal Connectors M23 ayonet Quick Selection Guide Edition 03/02 Number of Contacts (View: mating face) Contact

More information

PowerDRIVE-Box GEL 6505 Interface for controlling up to 5 positioning drives

PowerDRIVE-Box GEL 6505 Interface for controlling up to 5 positioning drives PowerDRIVE-Box GEL 6505 Interface for controlling up to 5 positioning drives Technical information Version 208-05 GEL 6505A: Box for top hat rail mounting, IP 20 variant General The PowerDRIVE-Box GEL

More information

PV Rapid Shutdown device

PV Rapid Shutdown device PV Rapid Shutdown device Installation and Operation Manual Solis-RSD-1G(1:1) Solis-RSD-1G(2:2) Manufacturer: Ginlong (Ningbo) Technologies Co.,Ltd., Ningbo, Zhejiang, P.R.China US Office: 565 Metro Pl.

More information

Product Details. Contents. Features and Mounting Options for SUNNY STRING-MONITOR SSM24-11

Product Details. Contents. Features and Mounting Options for SUNNY STRING-MONITOR SSM24-11 Technical Information Product Details Features and Mounting Options for SUNNY STRING-MONITOR SSM24-11 Contents The Sunny String Monitor SSM24 11 is specifically designed for monitoring large PV generators.

More information

HST -TZ1 Guard-locking mechanism (Translation of Original Manual)

HST -TZ1 Guard-locking mechanism (Translation of Original Manual) Installation and Operating Manual for Components HST -TZ1 Guard-locking mechanism (Translation of Original Manual) HST-TZ1 Ident.-No.: 10234 HST-TZ1 Ident.-No.: 10236 HST-TZ1 Ident.-No.: 10235 HST-TZ1

More information

DIN Rail Mounted Terminals & Accessories

DIN Rail Mounted Terminals & Accessories DIN Rail Mounted Terminals & Accessories PAGE PAGE STANDARD CONTA-CONNECT RANGE 253 NEW! CABLECRAFT ABS-S ENCLOSURES 260 DOUBLE & TRIPLE CONTA-CONNECT RANGE 254 NEW! CABLECRAFT ALUMINIUM ENCLOSURES 260

More information

Safety switches with separate actuator

Safety switches with separate actuator A Safety switches with separate actuator Selection diagram VF KEYF VF KEYF1 VF KEYF2 VF KEYF3 VF KEYF VF KEYF ACTUATORS CONTACT BLOCKS 9 snap action overlapped FD FP FL FC 21 22 33 3 3NC 2NO+1NC 1NO+ CONDUIT

More information

ODU MINI-SNAP PC Product Description. ODU MINI-SNAP PC: The Connector with Push-Pull-Locking in Plastic

ODU MINI-SNAP PC Product Description. ODU MINI-SNAP PC: The Connector with Push-Pull-Locking in Plastic ODU MINI-SNAP PC Product Description ODU MINI-SNAP PC: The Connector with Push-Pull-Locking in Plastic Cylindrical Connectors are generally available with several locking mechanisms: The most frequently

More information

revos revos Industrial Multipole Connectors 3 48 pole in metal housing Program for Tough Tasks

revos revos Industrial Multipole Connectors 3 48 pole in metal housing Program for Tough Tasks revos Industrial Multipole Connectors 3 8 pole in metal housing Program for Tough Tasks Heavyduty industrial plug connectors for all applications The heavyduty industrial plug connectors revos are classified

More information

for a perfect electrical installation. The range of rail-mounted terminal blocks

for a perfect electrical installation. The range of rail-mounted terminal blocks The range of rail-mounted terminal blocks for a perfect electrical installation. The range of rail-mounted terminal blocks for a perfect electrical installation. The new standard for rail-mounted terminal

More information

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016 Operating instructions AS-i SmartLine module AC3200 AC3201 80237876/00 06/2016 Contents 1 Preliminary note...3 1.1 Symbols used...3 1.2 Warnings used...3 2 Safety instructions...3 2.1 General...3 2.2 Target

More information

Operating instructions Hinge safety switch TESZ. 1. About this document. Content

Operating instructions Hinge safety switch TESZ. 1. About this document. Content 1. bout this document Operating instructions.............pages 1 to 6 Original 1.1 Function This operating instructions manual provides all the information you need for the mounting, set-up and commissioning

More information

Actuators for air and gas dampers

Actuators for air and gas dampers 7 818 Actuators for air and gas dampers SQM9... Electromotoric actuators Torques up to 60 Nm Running times ¹) 30...120 s ¹) Predefined by the basic unit (LMV5...) The SQM9... and this Data Sheet are intended

More information

Operating instructions. Switching amplifier DN0210 DN / / 2015

Operating instructions. Switching amplifier DN0210 DN / / 2015 Operating instructions Switching amplifier DN0210 DN0220 UK 80011079 / 00 01 / 2015 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5

More information

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only.

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only. Keithley Instruments, Inc. 28775 Aurora Road Cleveland, Ohio 44139 (440) 248-0400 Fax: (440) 248-6168 www.keithley.com Model 4200-RM Rack Mount Kit Packing List Introduction NOTE This 4200-RM Rack Mount

More information

Operating instructions Solenoid interlock AZM 200 T. 1. About this document. Content

Operating instructions Solenoid interlock AZM 200 T. 1. About this document. Content 7 Set-up and maintenance 7.1 Functional testing...7 7.2 Maintenance...7 Operating instructions............pages 1 to 10 Translation of the original operating instructions 8 Disassembly and disposal 8.1

More information

Operating instructions Safety-monitoring module AES 1102 AES About this document. Content. 8 Appendix 8.1 Wiring examples...

Operating instructions Safety-monitoring module AES 1102 AES About this document. Content. 8 Appendix 8.1 Wiring examples... 8 Appendix 8.1 Wiring examples...3 9 EU Declaration of conformity Operating instructions.............pages 1 to 6 Original x.000 / 11.2017 / v.a. - 101126006- / H / 2017-11-17 / AE-Nr. 8410 Content 1 About

More information

Distributed by: www.jameco.com 1-800-831-4242 The content and copyrights of the attached material are the property of its owner. HIGH POWER CONNECTORS Panel Mounts and Cord Plugs HPC Series Switchcraft

More information

FOR PC BOARD TO FLAT CABLE

FOR PC BOARD TO FLAT CABLE AXM FOR PC BOARD TO FLAT CABLE MIL CONNECTORS (AXM) Density mounting Long lever type Short lever type Compliance with RoHS Directive FEATURES 1. High density mounting is possible. Even with mounting right

More information

PROCESS AUTOMATION. MANUAL Z-System. Zener Barriers ISO9001

PROCESS AUTOMATION. MANUAL Z-System. Zener Barriers ISO9001 PROCESS AUTOMATION MANUAL Z-System Zener Barriers ISO9001 With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery for Products and

More information

Zener Barriers Bulletin 937Z

Zener Barriers Bulletin 937Z Technical Data Zener Barriers Bulletin 937Z Topic Page Introduction 2 Mounting 2 Housing 3 Operating Principle 3 Specifications 6 Introduction Allen-Bradley Zener barriers are a cost-effective solution

More information

Safety switches with separate actuator

Safety switches with separate actuator 4 Safety switches with separate actuator Selection diagram VF KEYD VF KEYD1 VF KEYD VF KEYD VF KEYD VF KEYD6 VF KEYD VF KEYD10 ACTUATORS CONTACT BLOCKS 6 snap action overlapped FR FX FK FW 0 1 4 NC NO+1NC

More information

Safety switches with separate actuator

Safety switches with separate actuator Safety switches with separate actuator Selection diagram VF KEYD VF KEYD1 VF KEYD VF KEYD VF KEYD5 VF KEYD6 VF KEYD7 VF KEYD8 VF KEYD10 VF KEYD11 ACTUATORS FR FX FK FW 5 6 7 11 1 14 NC NC snap action snap

More information

Details of the Han-Terminal block connector Han D AV Han D AV Distributor Han E AV Han ES AV

Details of the Han-Terminal block connector Han D AV Han D AV Distributor Han E AV Han ES AV Contents -Terminal Block Connectors Page Details of the -Terminal block connector........................ 08.02 D................................................... 08.10 D Distributor...........................................

More information

The connector system by Amisco includes a complete range of solutions for the most common connections of the coils for solenoid valves.

The connector system by Amisco includes a complete range of solutions for the most common connections of the coils for solenoid valves. Connector Connector system The connector system by Amisco includes a complete range of solutions for the most common connections of the coils for solenoid valves. The connectors with cable entry conform

More information

Emergency power supply NV2.1-12iaE

Emergency power supply NV2.1-12iaE Ordering Data Designation Type Item no. 372 100 04 AX Supply of consumers even in case of failure or shutdown of the input / charging current circuit NiCd as energy store Intrinsically safe input voltage

More information

Product and Applications Description. Application Programs. Example of Operation. Installation Instructions. load circuit AC 230/400V L1 L2 L3 N

Product and Applications Description. Application Programs. Example of Operation. Installation Instructions. load circuit AC 230/400V L1 L2 L3 N Product and Applications Description Application Programs 20 A4 Binary 906401 4 binary outputs 1 status request available for each output 1 relation can be set allows 1 positive drive for each output initial

More information

Operating Instructions

Operating Instructions Introduction To protect the signal lines of field devices and systems in the cabinet against lightning. Pepperl+Fuchs covers the complete range of Surge Protection Barriers. Housing types Depending on

More information

Products according to UIC 558 VE

Products according to UIC 558 VE Products according to UIC 558 VE Connectors according to UIC 558 VE The connector is used in international transport for vehicles, including locomotives, and connects lines for remote switching, remote

More information

SBE 80 / SBO 60 Connectors - up to 80 Amps

SBE 80 / SBO 60 Connectors - up to 80 Amps Connectors - up to 80 Amps SBE and SBO connectors build on the capability of the two pole SB connectors by offering up to 8 auxiliary power / signal contacts along with an IEC 60950 touch safe housing.

More information

Type 6150 AS-Interface Module. Type 3372 Electropneumatic Actuator with AS-interface module. Mounting and Operating Instructions EB 6150 EN

Type 6150 AS-Interface Module. Type 3372 Electropneumatic Actuator with AS-interface module. Mounting and Operating Instructions EB 6150 EN Type 6150 AS-Interface Module Type 3372 Electropneumatic Actuator with AS-interface module Mounting and Operating Instructions EB 6150 EN Edition July 2013 Definition of the signal words used in these

More information

Plugs & sockets. Industrial plugs and sockets - Scame I-1 4. Industrial switched sockets - Scame I-4 5. Distribution assemblies - Scame I-6

Plugs & sockets. Industrial plugs and sockets - Scame I-1 4. Industrial switched sockets - Scame I-4 5. Distribution assemblies - Scame I-6 I Product page Industrial plugs and sockets - Scame I-1 4 Industrial switched sockets - Scame I-4 5 Distribution assemblies - Scame I-6 Industrial plug adaptors - Scame I-6 Weatherproof domestic switches

More information

Operating instructions Two-hand control panel and stands. SEPK02.0 / SEPG05.3 / SEP01.0 /SEP01.4 / SEPLC05.2 / SEP07.0 / SEP09.

Operating instructions Two-hand control panel and stands. SEPK02.0 / SEPG05.3 / SEP01.0 /SEP01.4 / SEPLC05.2 / SEP07.0 / SEP09. 4.13 Dimensions stand STP01.1 /STP01.4....6 4.14 Dimensions stand STP01.5......6 4.15 Dimensions stand STP02.1 /STP02.4....6 4.16 Mounting on walls / machine parts...7 4.17 Mounting on stands....7............pages

More information

Datasheet - RSS 36-D-R-ST

Datasheet - RSS 36-D-R-ST 14.03.2018-19:30:37h Datasheet - RSS 36-D-R-ST Safety sensors / RSS 36 Thermoplastic enclosure RFID-technology for needs-based protection against tampering Misaligned actuation possible 27 mm x 108.2 mm

More information

Explosion-Protected Arc-Fault Protection ExAFCI Arc-Fault Circuit Interrupter

Explosion-Protected Arc-Fault Protection ExAFCI Arc-Fault Circuit Interrupter Installation, Operation & Maintenance Sheet Explosion-Protected Arc-Fault Protection ExAFCI Arc-Fault Circuit Interrupter > Contents 1 Contents 1 Contents...2 2 General Information...2 2.1 Manufacturer...2

More information

User Manual HMI Linkbox HL01 DP/MPI

User Manual HMI Linkbox HL01 DP/MPI User Manual HMI Linkbox HL01 DP/MPI Part Number: 80860.603 Version: 1 Date: 07.05.2005 Valid for: HL01 DP/MPI Version Date Modifications 1 07.05.2005 First edition This manual, including all illustrations

More information

Supplementary instructions. Plug connector ISO for level sensors. Document ID: 30380

Supplementary instructions. Plug connector ISO for level sensors. Document ID: 30380 Supplementary instructions Plug connector ISO 4400 for level sensors Document ID: 30380 Contents Contents For your safety. Appropriate use... 3.2 General safety instructions... 3.3 Safety instructions

More information

Features / Options. - MP-62 Series

Features / Options. - MP-62 Series MULTIPIN CONNECTORS Amphenol has an extensive range of circular and rectangular multipin connectors ideally suited to the entertainment industry. Featuring rugged housings and precision made contacts these

More information

D-Series High Reliability Circular Connectors

D-Series High Reliability Circular Connectors D-Series High Reliability Circular Connectors Technology Company, Inc. integramate D-Series Circular Connectors QA Technology integramate D-Series Connectors are high quality, plastic circular connectors

More information

Operating instructions Safe AS-i input module ASIM-C-M About this document. Content

Operating instructions Safe AS-i input module ASIM-C-M About this document. Content 7 Set-up and maintenance 7.1 Functional testing....10 7.2 Maintenance...10 EN Operating instructions.............pages 1 to 6 Original 8 Disassembly and disposal 8.1 Disassembly....10 8.2 Disposal...10

More information