vsan 6.6 Performance Improvements First Published On: Last Updated On:

Size: px
Start display at page:

Download "vsan 6.6 Performance Improvements First Published On: Last Updated On:"

Transcription

1 vsan 6.6 Performance Improvements First Published On: Last Updated On:

2 Table of Contents 1. Overview 1.1.Executive Summary 1.2.Introduction 2. vsan Testing Configuration and Conditions 2.1.Hardware and vsan Configurations 2.2.Measurements 3. Performance Comparisons and Findings 3.1.Large Working Set 3.2.Small Working Set 3.3.Latency Improvements 3.4.Additional Performance Benefits 4. Enhancements behind Performance Improvements 4.1.Enhancements in vsan Summary 2

3 1. Overview Provides an executive summary, and an introduction to the objective of the document 3

4 1.1 Executive Summary Executive Summary VMware vsan 6.6 delivers a new level of performance and consistency of VMs running in VMware's integrated Hyper-Converged Infrastructure (HCI) platform. Driving additional performance entirely through a software update, with no additional costs in hardware or software, demonstrates the power of a software defined data center. The test results shared in this document show the ability for vsan 6.6 to deliver a 50%, or greater, performance improvement under a variety of workload conditions, using common data services such as deduplication, compression, and data integrity features such as software checksum. vsan 6.6 not only demonstrates improved IOPS and throughput with decreased latency as compared to vsan 6.5, but it does so with more consistent results. Lower and more predictable latencies are what application owners expect in delivering solutions and addressing their business objectives. Faster, more efficient delivery of storage in vsan allows organizations to run more workloads per host while still meeting performance expectations. 1.2 Introduction Introduction vsan 6.6 introduced several improvements that aim to improve the efficiency and performance of vsan. Some enhancements focused on data management improvements. These optimizations improved the efficiency of maintaining the health and balance of data on vsan. These improvements have been detailed in the "VMware vsan Intelligent Rebuilds" Technical Note. This document focuses on the performance improvements as a result of enhancements that allow vsan to deliver improved storage I/O performance when using the very same underlying hardware running vsan 6.5. These improvements are not limited to just I/O activity related to read and write requests from the VM, but also data management activity such as resynchronization and rebuilds. 4

5 2. vsan Testing Configuration and Conditions Details the hardware and software settings used when running these tests in a controlled environment. 5

6 2.1 Hardware and vsan Configurations vsan Testing Configuration and Conditions The objective of the testing described is to observe the comparative advantages of vsan 6.6 over vsan 6.5. The test methods used for evaluation comprise of a series of micro-benchmarks to evaluate the performance improvements of data services (e.g. checksum), space efficiency features (Deduplication & Compression) and fault tolerance methods (FTM) independently, and together. The battery of tests were run against a large working set of data, and a small working set of data. The combination of these conditions provide the best cross section of conditions necessary to evaluate the improvements in performance in vsan 6.6. Hardware and vsan Configurations The test conditions for all comparisons between vsan 6.5, and vsan 6.6 remained the same, and are as follows: Hardware Physical Hosts: SuperMicro Sys-2028u-TNRT+ with Intel Haswell-EP E v3 processors Host count: Four hosts comprising one vsan cluster Disk groups: Each host consist of two disk groups. Each disk group has a single 400GB Intel P3700 NVMe flash device, and three 800GB Intel S3500 SATA SSD flash devices. Software Hypervisor versions tested: vsphere 6.5 versus vsphere 6.5 EP2 (aka vsan 6.6). In order to sufficiently accommodate the larger working sets, the vsan 6.5 configuration in this test used adjustments similar to the manual settings described in VMware vsan 6.0 Performance: Scalability and Best Practices. Worker VMs: A quantity of 8 VMs were used on each host, with one virtual disk per VM Data placement: Working set of data is split across the virtual disks on each host Data uniqueness: In any testing involving deduplication and compression, the workload buffer is configured for 0% of the data to be deduped, or compressed. Working sets tested Two sizes were used for working sets on each test scenario. The large and small working set sizes attempt to simulate two distinct conditions commonly found with production workloads. Large working sets reflect a considerable amount of active, or hot data relative to the size of any caching or buffering tiers. Small working sets reflect a smaller amount of hot data relative to the size of any caching or buffering tiers. Large working set configuration: This configuration consists of a working set size of 1680GB per host, and occupies about 60% of the total storage capacity of the vsan cluster. With two disk groups per host, the 400GB NVMe drive in each disk group does not allow for the working set to fit in the 800GB buffer space per host. This creates a large, sustained amount of destaging activity after the test is ramped up. Small working set configuration: This configuration consists of a working set size of 200GB per host for random I/Os, and 400GB per host for sequential I/Os. This size allows the working set to fit within the capacity of the 2, 400GB NVMe buffering devices on each host. Just as with the large working set, the test data collected is are all based on steady state numbers. The definition of large and small working set sizes are for the purposes of these test scenarios only. In production environments, determining working set sizes, and their respective cache coherency can be challenging. For this reason, the primary focus of the test results will be on the large working set tests, which will generate the most conservative test results. 6

7 Data Services and protection schemes tested vsan is an object based storage system. Unlike traditional storage systems, this allows data services such as software checksum, or a failure tolerance method (FTM) to be assigned as a storage policy on a per VM, or VMDK basis. Each test case was run under four distinct configurations. Table 1 shows the combination of testing used against vsan 6.5 and vsan 6.6. All testing used the same hardware, and the same test methods for each scenario. Table 1. Conditions tested Other combinations of data services and protection schemes exist, but this test was limited to the scenarios listed in Table 1. Access patterns tested Each test condition included the following I/O patterns. Random Read Random Write Mixed random Read/Write (70/30%) Production workloads will often have a mix of these patterns throughout the course of a given time period. In most cases, the aggregation of multiple workloads across a collection of hosts will blend discrete patterns into a mix of random reads and random writes. This is the primary reason why mixed, random I/O is the most prevalent pattern in production, virtualized environments, and is the area of emphasis in the analysis of the test results. 2.2 Measurements Measurements Testing of performance measures data activity in the form of I/O commands successfully completed per second (IOPS). IOPS is an aggregation, or sum of the total IOPS generated by worker VMs. Latency is the time in microseconds (us) or milliseconds (ms) and may be referred to for readability. Latency defines the time needed to complete a read or a write operation. Latency data reported is an average. Throughput, which is the amount of payload transmitted per second, is omitted for clarity. All random I/O tests used 4K for an I/O size. Test results provided in this document are reported as a percentage of change when comparing vsan 6.5 to vsan 6.6. The test results in this document refer to data collected from an all-flash cluster. The performance improvements included in vsan 6.6 will apply to both hybrid, and all-flash based vsan clusters, but the degree of improvement will be different due to caching considerations, as well as the physical properties of spinning disks. Deduplication and Compression is a feature exclusive to all-flash based configurations and enterprise based vsan licensing. 7

8 3. Performance Comparisons and Findings Provides the test results in a number of different ways to demonstrate the performance differences between vsan 6.5, and vsan

9 3.1 Large Working Set Large Working Set Tests using a large working set are designed to simulate workloads that have a large amount of data that is active, thereby flushing out any recently accessed data preserved through caching, or buffering to a faster tier of storage. Characteristics of a large working set typically involves large amounts of sustained writes, with read requests for data that is well outside of the capacity of any buffering and caching tier. Large amounts of sustained writes, which contribute to generating a large working set, generally represent the most lowest performance results for any storage system. Testing large working sets helps establish a minimum level of performance and consistency. Overview of Improvement The following test results summarize the changes in effective performance under the conditions outlined in the vsan Testing Configuration and Conditions section in this document. Test results of IOPS and latency against multiple I/O patterns are measured as a percentage of improvement from vsan 6.5 to vsan 6.6. Smaller bars do not indicate less performance, but simply less improvement. Figure 1 shows the percentage of performance improvement under a variety of different I/O patterns, using a large working set of data. It is easy to see that improvements are greater as more data services are used. The most significant improvements come with all tested data services (RAID-5 Erasure Coding, checksum, Dedup & Compression) enabled. All random patterned I/O (random read, random write, and mixed) demonstrated significant improvement in vsan 6.6. The mixed workload using all data services improved by 63.5%. The same workload, but using just checksum and RAID-5, improved by 56.3%. Figure 1. Improvement in IOPS for vsan 6.6 over vsan 6.5 Large working sets 9

10 The reductions in latency shown in Figure 2 generally correspond with IOPS improvements described in Figure 1. When using a large working set with a mixed workload using all data services, latency was reduced by 39.8%. This same test with using just RAID-5 and checksum yields a latency reduction of 37.4%. Notable improvements also show up in the random write test, where a latency reduction of 20.2% occurs when using all data services, and a 35.1% reduction when using just RAID-5 and checksum. Figure 2. Reduction in latency for vsan 6.6 over vsan 6.5 Large working sets The reductions in latency are the best measurement to understand how real production workloads can benefit from the performance enhancements. Results of common I/O patterns For large working sets, the data above shows that the mixed workloads saw the most improvement. Two I/O pattern types will be examined in more detail to to better understand the results. Figure 3 shows that for a 70/30 mixed workload using a large working set, a 28.5% and 63.5% increase in IOPS was observed when using data services. This allowed vsan 6.6 to drive more IOPS with all data services than vsan 6.5 using just RAID-5 and checksum. 10

11 Figure 3. Improvement of IOPS for a 70R/30W mixed workload with a large working set In Figure 4, the latency improvements for those corresponding IO improvements are equally impressive, ranging between 22.5% and 39.8% reduction in latency. This allowed vsan 6.6 to provide less latency for all services (Deduplication & Compression, RAID-5, and checksum) than vsan 6.5 using just RAID-5 and checksum. Figure 4. Reduction in latency for a 70R/30W mixed workload with a large working set 11

12 Long periods of random writes using a large working set is a challenging I/O pattern to improve upon. With the improvements shown in Figure 5, vsan 6.6 was able to deliver more IOPS with using RAID-5 and checksum than the same test run on vsan 6.5 using just checksum. Figure 5. Improvement in IOPS for a random write workload with a large working set This type of I/O scenario is particularly difficult to improve upon because it is largely dependent on the constraints and characteristics of the physical hardware. The reduction in latency shown in Figure 6 allowed vsan 6.6 to deliver lower effective latency with using RAID-5 and checksum, than the same test run on vsan 6.5 using just checksum. 12

13 Figure 6. Reduction in latency for a random write workload with a large working set While large amounts of random write operations sustained across a long period of time can be difficult for any storage system, it is important to recognize the effective improvements made in reducing latency, especially when multiple data services are used. Figure 5 and Figure 6 show that for tests running only checksum, the improvement was less significant than the improvement with other data services. The result in this specific test case is due to RAID-1 (mirroring) being constrained by the limit of components the I/Os are written to. In the checksum test, RAID-1 with checksum is written to two mirrored components. Writing data to two components triggered congestion, which reduced the level of improvement. In the checksum with RAID-5 test, the data was striped across four components (3 data + 1 parity). Writing the data across four components eliminated the component congestion, and demonstrated a significant increase in IOPS, and reduction in latency. Summary of Analysis Several observations can be taken from the data provided of these tests against large working sets. All profiles of random I/O generation demonstrated significant improvement in performance. We can see clearly that in the case of mixed I/O patterns, vsan 6.6 delivered over a 60% increase in IOPS, and nearly a 40% reduction in latency when comparing the same test between vsan 6.5. vsan 6.6 is often able to drive higher performance (more I/O, less latency), using a broader set of data services than vsan 6.5 using a reduced set of data services. vsan 6.6 demonstrates a consistent, reduction of impact on performance with the use of data services and protection policies. Areas of benefit Mixed workload patterns are the most common I/O profile found in virtualized environments, and where vsan 6.6 reports some of the most significant performance improvements. Pairing this with 13

14 applications that have large working sets, the following are some examples of environments and applications that may see the most benefit. Large batch processes from databases, and structured data sets. ERP systems often have this type of activity. Transactional applications. These are applications that have a serialized I/O dialog in which the next write is waiting on the previous read. Latency is critical in these types of applications. Unstructured data. File servers, and data warehouse environments. High density of VMs per physical host. This randomizes I/O patterns, and has a greater potential for contention as a result of bursts from more VMs. Latency sensitive applications. These often have strict service level requirements defined in deployment guides. 3.2 Small Working Set Small Working Sets Tests using a small working set of data are designed to simulate workloads that have a set of data that fits within a given boundary of allocated caching and buffering of the storage system. Characteristics of this small working set typically involves a blend of recently accessed data, read or written, that remains in the caching tier for subsequent reads. Modest sized working sets are more representative of a general-purpose workload that have relatively frequent, repeating tasks over a period of time, or duty cycle. Despite small working sets not being representative of every workload, including them in a battery of tests serves a very specific purpose when testing software optimizations like those made in vsan 6.6. In many cases, test results from smaller working sets better represent optimizations made to a software stack, as it is less reliant on characteristics and constraints of hardware components used in a specific test. Testing small working sets in conjunction with large working sets also helps demonstrate effective performance when application workloads and workflows are able to take advantage of cached content. Caching is an important aspect of any data center, and exists in compute, network, and storage. Overview of Improvement The following test results summarize the changes in effective performance under the conditions outlined in the vsan Testing Configuration and Conditions section in this document. Test results of IOPS and latency against multiple I/O patterns are measured as a percentage of improvement from vsan 6.5 to vsan 6.6. Smaller bars do not indicate less performance, but simply less improvement. Figure 7 illustrates substantial improvements across a variety of I/O profiles when using a smaller working set size. The most significant improvements are a result of when data services such as checksum, RAID-5, and Dedup & Compression are enabled. Just as with the testing with a large working set, all random patterned I/O (random read, random write, and mixed) demonstrated significant improvement in vsan 6.6. For a mixed workload, using all data services improved by 52.3%. The same workload, but using just checksum and RAID-5, improved by 86%. Particularly interesting is the improvement in performance of random writes. Using all data services, there was a 48% improvement in performance. The same workload, but using just checksum and RAID-5 showed a 74.4% improvement. 14

15 Figure 7. Improvement in IOPS for vsan 6.6 over vsan 6.5 Small working sets The improvements in latency illustrated in Figure 8 shows reductions that mirror performance increases of IOPS described in Figure 7. When using a small working set with a mixed workload, and all data services saw a 35.6% reduction in latency. The same test using just RAID-5 and checksum saw a 47.7% reduction. Latencies on random writes were also improved dramatically, where latency reductions of 33.4% were observed when using all data services, and a 44% reduction when using just RAID-5 and checksum. Note that when no data services are used, there is less opportunity for improvement in data path optimization. An example of this is shown in Figure 8, but can also be found in other test results in this document. This specific test result shows a slight regression for random reads when no data services are used. The actual latency measurements for this specific test were 830us (microseconds) compared to 833us, which equates to a 0.36% increase in latency. These small variances (+/-) can be the result of fluctuating behaviors throughout the entire stack, including all hardware components, and fall well within the range of variability across multiple test runs, even under extremely controlled environments. 15

16 Figure 8. Reduction in latency for vsan 6.6 over vsan 6.5 Small working sets Latency reductions using the smaller working set can be representative of the effective performance improvement that some workloads in a production environment would see. Results of common I/O patterns Much like the large working sets, the data above shows that when using smaller working sets, mixed workloads saw the most improvement. Two I/O pattern types will be examined in more detail to to better understand the results. For a 70/30 mixed workload using a smaller working set, we see between a 52.3% and 86% increase in IOPS when using data services. With the dramatic increases shown in Figure 9, this allowed vsan 6.6 to drive almost as many IOPS when using all data services (Deduplication & Compression, RAID-5, and checksum) as vsan 6.5 using just checksum. 16

17 Figure 9. Improvement in IOPS for a mixed workload with a small working set The latency reductions for those corresponding IO improvements reinforce the performance gains shown in Figure 9. These latency reductions ranged from 35.6% to 47.7%. The amount of reduction in latency shown in Figure 10 allowed vsan 6.6 to run all data services (Deduplication & Compression, RAID-5, and checksum) at about the same latency to vsan 6.5 using just checksum. Figure 10. Reduction in latency for a random write workload with a small working set Random writes using a smaller working set exposes more of the performance gains built into vsan 6.6 than the same test using a large working set. As shown in Figure 11, improvements ranged between 25.3% and 75.5% when using data services. 17

18 Figure 11. Improvement in IOPS for a random write workload with a small working set Latency reductions for random writes were significant. When using data services, Figure 12 shows latency reductions ranging from 21.7% to 44%. Not only were the latencies lower in vsan 6.6, but there is less of a variance between latency when selecting the respective data services. Figure 12. Reduction in latency for a random write workload with a small working set While large amounts of sustained random write operations can be a challenge for any storage system, the results showing the improvements when testing a small working set of data is most representative of production workloads that have short duty cycles with a modestly sized working set. 18

19 Summary of Analysis Running the same battery of tests using a smaller working set provides a number of interesting observations. All profiles of random I/O generation demonstrated significant improvement in performance. In cases of mixed I/O patterns, there were increases in IOPS of up to 86%, and reductions of latency of up to 47.7% when comparing the same test between vsan 6.5 and vsan 6.6. vsan 6.6 is consistently able to drive higher performance (more I/O, less latency), using a broader set of data services than vsan 6.5 using a limited set of data services. Significant performance improvement on checksum were realized for a larger variety of reads and writes. This is even more visible in a smaller working set. vsan 6.6 demonstrates a consistent, reduction of impact on performance with the use of data services and protection policies. Testing smaller working set sizes showcases the potential benefits that can occur with workloads that have smaller working sets as a result of an overall smaller footprint of data, or shorter duty cycles. Areas of benefit Just as with workloads using large working sets, applications that have a mixed I/O pattern combined with a smaller working set will see significant improvements in vsan 6.6. Applications and scenarios that would see benefit would include, but are not limited to the following. Multi-tier, and scale out applications. These types of application architectures tend to have smaller working sets of data dispersed across the application nodes. VDI environments. These environments have a number of different workload profiles depending on what task is being performed. Transactional applications. These are applications that have a serialized I/O dialog in which the next write is waiting on the previous read. Latency is critical in these types of applications. High density of VMs per physical host. This randomizes I/O patterns, and has a greater potential for contention as a result of bursts from more VMs. The reduction in latency will allow for VMs to deliver a lower, more consistent level of latency. Latency sensitive applications. These often have strict service level requirements defined in deployment guides. 3.3 Latency Improvements Latency Improvements Delivering minimal latency consistently over long periods of sustained activity is a challenge for any storage architecture. Latency of a VM is the best way to measure if the underlying infrastructure is able to deliver adequate performance to an application. Higher latency translates to a longer time a task takes to be completed. Predictable, low latency over a period of time is a desired result for application owners, but can be difficult for storage systems to deliver. vsan 6.6 makes significant improvements in this area. Tests that ran for a duration of 4 hours showed significant improvement in the predictability and consistency of latency in vsan 6.6. When viewing the range of latencies, (low mark to 95th percentile peak), vsan 6.6 exhibited over an 80% reduction in latency deviation as compared to vsan Additional Performance Benefits 19

20 Additional Performance Benefits An increase in IOPS with a reduction in latency can also represent an additional benefit not explicitly measured in this testing. This benefit would show in the form of a reduction of host CPU utilization when comparing steady state, non-synthetic workloads, which is more representative of production environments. Synthetic testing is meant to stress resource usage, and thus, free CPU cycles will be used for processing additional I/O. With steady state workloads, I/O's would be processed more quickly, which reduces the length of time in which host CPU resources are being utilized. Reducing host resources could increase the density of running VMs that could be achieved on a host. 20

21 4. Enhancements behind Performance Improvements Describes the specific enhancements that had the most influence on the improved test results in vsan

22 4.1 Enhancements in vsan 6.6 Enhancements behind Performance Improvements The test comparisons provided in this document showcase the improvements in performance as a result of four specific enhancements. Checksum optimizations. Checksum is a technique that provides an additional layer of data integrity for data in flight, or at rest. Checksum is a storage policy setting, applied per object, and is turned on unless explicitly disabled in a policy. Improvements with checksum come from several optimizations. The improvements result in gains in performance on both read and write operations. Write buffer destaging optimizations. Destaging is the act of moving recently written data from the write buffer to the capacity tier. Data coming into the buffer can be place more efficiently, which helps reduce the fill rate and usage of the buffer. More proactive destaging of data helps reduce meta-data build up that could impact guest I/O or resync operations. This helps scenarios with large numbers of deletes, which invoke metadata writes. More aggressive destaging can help in write intensive environments, especially when using RAID-5/6, reducing times in which vsan must experiences "Congestions," vsan's built in mechanism of controlling contention in the storage system. Deduplication and Compression improvements. Deduplication and Compression is a clusterwide feature in vsan that improves space efficiency, and is applied as data is destaged from the write buffer to the capacity tier. vsan 6.6 changes the approach in ordering of the data to be destaged. This offers more predictable performance, especially with sequential writes. Object management improvements. vsan is an object based storage system, and manages its duties by the use of an object manager. vsan 6.6 has tuned the use of memory by the object manager to help reduce the amount of CPU overhead. This optimization reduces heavy context switching of cache and CPU, making delivery if I/O more efficient. These performance benefits outlined also extend to back-end vsan management activities such as rebalancing, resyncing, and repairing of objects. These are activities that will happen in any environment, regardless of the workload type. 4.2 Summary Summary vsan 6.6 provides a substantial improvement in performance over vsan 6.5, all with the simple click of a software upgrade. Better performance will allow administrators to provide higher, more consistent levels of performance for the applications and services powered by vsan, and gives environments the ability to absorb increases in performance and efficiency as more workloads are introduced to a vsan powered environment. About the Author This content in this document was assembled using data collected from extensive testing efforts by the VMware Performance Engineering Team. You can read more from the Performance Engineering team on their blog at VMware VROOM! Pete Koehler is a Sr. Technical Marketing Manager, working in the Storage and Availability Business Unit at VMware, Inc. He specializes in enterprise architectures, data center analytics, software-defined storage, and hyper-converged Infrastructures. Pete provides more insight to challenges of the data center at vmpete.com, and VMware s Virtual Blocks. He can also be found on twitter 22

Disclaimer This presentation may contain product features that are currently under development. This overview of new technology represents no commitme

Disclaimer This presentation may contain product features that are currently under development. This overview of new technology represents no commitme STO1926BU A Day in the Life of a VSAN I/O Diving in to the I/O Flow of vsan John Nicholson (@lost_signal) Pete Koehler (@vmpete) VMworld 2017 Content: Not for publication #VMworld #STO1926BU Disclaimer

More information

Adaptive Resync in vsan 6.7 First Published On: Last Updated On:

Adaptive Resync in vsan 6.7 First Published On: Last Updated On: First Published On: 04-26-2018 Last Updated On: 05-02-2018 1 Table of Contents 1. Overview 1.1.Executive Summary 1.2.vSAN's Approach to Data Placement and Management 1.3.Adaptive Resync 1.4.Results 1.5.Conclusion

More information

What's New in vsan 6.2 First Published On: Last Updated On:

What's New in vsan 6.2 First Published On: Last Updated On: First Published On: 07-07-2016 Last Updated On: 08-23-2017 1 1. Introduction 1.1.Preface 1.2.Architecture Overview 2. Space Efficiency 2.1.Deduplication and Compression 2.2.RAID - 5/6 (Erasure Coding)

More information

Performance Testing December 16, 2017

Performance Testing December 16, 2017 December 16, 2017 1 1. vsan Performance Testing 1.1.Performance Testing Overview Table of Contents 2 1. vsan Performance Testing Performance Testing 3 1.1 Performance Testing Overview Performance Testing

More information

vsan Space Efficiency Technologies First Published On: Last Updated On:

vsan Space Efficiency Technologies First Published On: Last Updated On: vsan Space Efficiency Technologies First Published On: 11-18-2016 Last Updated On: 01-12-2018 1 Table of Contents 1. Introduction 1.1.Overview 1.2.Why the Future is All-Flash 2. Deduplication 2.1.Deduplication

More information

Understanding Data Locality in VMware vsan First Published On: Last Updated On:

Understanding Data Locality in VMware vsan First Published On: Last Updated On: Understanding Data Locality in VMware vsan First Published On: 07-20-2016 Last Updated On: 09-30-2016 1 Table of Contents 1. Understanding Data Locality in VMware vsan 1.1.Introduction 1.2.vSAN Design

More information

VMware Virtual SAN 6.2 Space Efficiency Technologies

VMware Virtual SAN 6.2 Space Efficiency Technologies VMware Virtual SAN 6.2 Technical White Paper March 2016 Contents Introduction... 3 Why the future is all-flash... 3 Deduplication and Compression... 5 Observations and Recommendations... 7 RAID-5/6...

More information

Disclaimer This presentation may contain product features that are currently under development. This overview of new technology represents no commitme

Disclaimer This presentation may contain product features that are currently under development. This overview of new technology represents no commitme STO1515BU Extreme Performance Series: vsan Performance Troubleshooting Amitabha Banerjee and Suraj Kasi #VMworld #STO1515BU Disclaimer This presentation may contain product features that are currently

More information

vsan Mixed Workloads First Published On: Last Updated On:

vsan Mixed Workloads First Published On: Last Updated On: First Published On: 03-05-2018 Last Updated On: 03-05-2018 1 1. Mixed Workloads on HCI 1.1.Solution Overview Table of Contents 2 1. Mixed Workloads on HCI 3 1.1 Solution Overview Eliminate the Complexity

More information

Intelligent Rebuilds in vsan 6.6 January 08, 2018

Intelligent Rebuilds in vsan 6.6 January 08, 2018 January 08, 2018 1 Table of Contents 1. Introduction 1.1.Executive Summary 1.2.Introduction to Intelligent Rebuilds 2. vsan 6.6 Intelligent Rebuilds 2.1.Purpose of Intelligent Rebuilds 2.2.Intelligent

More information

Microsoft SQL Server 2014 on vsan 6.2 All-Flash December 15, 2017

Microsoft SQL Server 2014 on vsan 6.2 All-Flash December 15, 2017 Microsoft SQL Server 2014 on vsan 6.2 All-Flash December 15, 2017 1 Table of Contents 1. Microsoft SQL Server 2014 on vsan 6.2 All-Flash 1.1.Executive Summary 1.2.vSAN SQL Server Reference Architecture

More information

Nimble Storage Adaptive Flash

Nimble Storage Adaptive Flash Nimble Storage Adaptive Flash Read more Nimble solutions Contact Us 800-544-8877 solutions@microage.com MicroAge.com TECHNOLOGY OVERVIEW Nimble Storage Adaptive Flash Nimble Storage s Adaptive Flash platform

More information

vsan Remote Office Deployment January 09, 2018

vsan Remote Office Deployment January 09, 2018 January 09, 2018 1 1. vsan Remote Office Deployment 1.1.Solution Overview Table of Contents 2 1. vsan Remote Office Deployment 3 1.1 Solution Overview Native vsphere Storage for Remote and Branch Offices

More information

VMware vsphere Clusters in Security Zones

VMware vsphere Clusters in Security Zones SOLUTION OVERVIEW VMware vsan VMware vsphere Clusters in Security Zones A security zone, also referred to as a DMZ," is a sub-network that is designed to provide tightly controlled connectivity to an organization

More information

Eliminate the Complexity of Multiple Infrastructure Silos

Eliminate the Complexity of Multiple Infrastructure Silos SOLUTION OVERVIEW Eliminate the Complexity of Multiple Infrastructure Silos A common approach to building out compute and storage infrastructure for varying workloads has been dedicated resources based

More information

Native vsphere Storage for Remote and Branch Offices

Native vsphere Storage for Remote and Branch Offices SOLUTION OVERVIEW VMware vsan Remote Office Deployment Native vsphere Storage for Remote and Branch Offices VMware vsan is the industry-leading software powering Hyper-Converged Infrastructure (HCI) solutions.

More information

vsan Security Zone Deployment First Published On: Last Updated On:

vsan Security Zone Deployment First Published On: Last Updated On: First Published On: 06-14-2017 Last Updated On: 11-20-2017 1 1. vsan Security Zone Deployment 1.1.Solution Overview Table of Contents 2 1. vsan Security Zone Deployment 3 1.1 Solution Overview VMware vsphere

More information

Understanding Data Locality in VMware Virtual SAN

Understanding Data Locality in VMware Virtual SAN Understanding Data Locality in VMware Virtual SAN July 2014 Edition T E C H N I C A L M A R K E T I N G D O C U M E N T A T I O N Table of Contents Introduction... 2 Virtual SAN Design Goals... 3 Data

More information

Disclaimer This presentation may contain product features that are currently under development. This overview of new technology represents no commitme

Disclaimer This presentation may contain product features that are currently under development. This overview of new technology represents no commitme STO1206BU Interpreting performance metrics in your vsan environment Pete Koehler (@vmpete) Bradley Mott #VMworld #STO1206BU Disclaimer This presentation may contain product features that are currently

More information

Microsoft SQL Server 2014 on VMware vsan 6.2 All-Flash October 31, 2017

Microsoft SQL Server 2014 on VMware vsan 6.2 All-Flash October 31, 2017 Microsoft SQL Server 2014 on VMware vsan 6.2 All-Flash October 31, 2017 1 Table of Contents 1. Executive Summary 1.1.Business Case 1.2.Solution Overview 1.3.Key Results 2. vsan SQL Server Reference Architecture

More information

vsan Stretched Cluster Bandwidth Sizing First Published On: Last Updated On:

vsan Stretched Cluster Bandwidth Sizing First Published On: Last Updated On: vsan Stretched Cluster Bandwidth Sizing First Published On: 07-20-2016 Last Updated On: 11-22-2017 1 Table of Contents 1. VSAN Stretched Cluster 1.1.Overview 1.2.General Guidelines 1.3.Bandwidth Requirements

More information

LATEST INTEL TECHNOLOGIES POWER NEW PERFORMANCE LEVELS ON VMWARE VSAN

LATEST INTEL TECHNOLOGIES POWER NEW PERFORMANCE LEVELS ON VMWARE VSAN LATEST INTEL TECHNOLOGIES POWER NEW PERFORMANCE LEVELS ON VMWARE VSAN Russ Fellows Enabling you to make the best technology decisions November 2017 EXECUTIVE OVERVIEW* The new Intel Xeon Scalable platform

More information

Pivot3 Acuity with Microsoft SQL Server Reference Architecture

Pivot3 Acuity with Microsoft SQL Server Reference Architecture Pivot3 Acuity with Microsoft SQL Server 2014 Reference Architecture How to Contact Pivot3 Pivot3, Inc. General Information: info@pivot3.com 221 West 6 th St., Suite 750 Sales: sales@pivot3.com Austin,

More information

Online Transaction Processing Workloads First Published On: Last Updated On:

Online Transaction Processing Workloads First Published On: Last Updated On: Online Transaction Processing Workloads First Published On: 07-20-2016 Last Updated On: 07-20-2016 1 Table of Contents 1. Executive Summary 1.1.Executive Summary 2. Introduction 2.1.Overview 2.2.vSAN 6.2

More information

Nutanix Tech Note. Virtualizing Microsoft Applications on Web-Scale Infrastructure

Nutanix Tech Note. Virtualizing Microsoft Applications on Web-Scale Infrastructure Nutanix Tech Note Virtualizing Microsoft Applications on Web-Scale Infrastructure The increase in virtualization of critical applications has brought significant attention to compute and storage infrastructure.

More information

vsan All Flash Features First Published On: Last Updated On:

vsan All Flash Features First Published On: Last Updated On: First Published On: 11-07-2016 Last Updated On: 11-07-2016 1 1. vsan All Flash Features 1.1.Deduplication and Compression 1.2.RAID-5/RAID-6 Erasure Coding Table of Contents 2 1. vsan All Flash Features

More information

Virtualization of the MS Exchange Server Environment

Virtualization of the MS Exchange Server Environment MS Exchange Server Acceleration Maximizing Users in a Virtualized Environment with Flash-Powered Consolidation Allon Cohen, PhD OCZ Technology Group Introduction Microsoft (MS) Exchange Server is one of

More information

DataON and Intel Select Hyper-Converged Infrastructure (HCI) Maximizes IOPS Performance for Windows Server Software-Defined Storage

DataON and Intel Select Hyper-Converged Infrastructure (HCI) Maximizes IOPS Performance for Windows Server Software-Defined Storage Solution Brief DataON and Intel Select Hyper-Converged Infrastructure (HCI) Maximizes IOPS Performance for Windows Server Software-Defined Storage DataON Next-Generation All NVMe SSD Flash-Based Hyper-Converged

More information

Running VMware vsan Witness Appliance in VMware vcloudair First Published On: April 26, 2017 Last Updated On: April 26, 2017

Running VMware vsan Witness Appliance in VMware vcloudair First Published On: April 26, 2017 Last Updated On: April 26, 2017 Running VMware vsan Witness Appliance in VMware vcloudair First Published On: April 26, 2017 Last Updated On: April 26, 2017 1 Table of Contents 1. Executive Summary 1.1.Business Case 1.2.Solution Overview

More information

VMWARE VSAN LICENSING GUIDE - MARCH 2018 VMWARE VSAN 6.6. Licensing Guide

VMWARE VSAN LICENSING GUIDE - MARCH 2018 VMWARE VSAN 6.6. Licensing Guide - MARCH 2018 VMWARE VSAN 6.6 Licensing Guide Table of Contents Introduction 3 License Editions 4 Virtual Desktop Infrastructure... 5 Upgrades... 5 Remote Office / Branch Office... 5 Stretched Cluster with

More information

Free up rack space by replacing old servers and storage

Free up rack space by replacing old servers and storage A Principled Technologies report: Hands-on testing. Real-world results. Free up rack space by replacing old servers and storage A 2U Dell PowerEdge FX2s and all-flash VMware vsan solution powered by Intel

More information

Webinar Series: Triangulate your Storage Architecture with SvSAN Caching. Luke Pruen Technical Services Director

Webinar Series: Triangulate your Storage Architecture with SvSAN Caching. Luke Pruen Technical Services Director Webinar Series: Triangulate your Storage Architecture with SvSAN Caching Luke Pruen Technical Services Director What can you expect from this webinar? To answer a simple question How can I create the perfect

More information

vsan Management Cluster First Published On: Last Updated On:

vsan Management Cluster First Published On: Last Updated On: First Published On: 07-07-2016 Last Updated On: 03-05-2018 1 1. vsan Management Cluster 1.1.Solution Overview Table Of Contents 2 1. vsan Management Cluster 3 1.1 Solution Overview HyperConverged Infrastructure

More information

StorMagic SvSAN 6.1. Product Announcement Webinar and Live Demonstration. Mark Christie Senior Systems Engineer

StorMagic SvSAN 6.1. Product Announcement Webinar and Live Demonstration. Mark Christie Senior Systems Engineer StorMagic SvSAN 6.1 Product Announcement Webinar and Live Demonstration Mark Christie Senior Systems Engineer Introducing StorMagic What do we do? StorMagic SvSAN eliminates the need for physical SANs

More information

VMware vsan 6.6. Licensing Guide. Revised May 2017

VMware vsan 6.6. Licensing Guide. Revised May 2017 VMware 6.6 Licensing Guide Revised May 2017 Contents Introduction... 3 License Editions... 4 Virtual Desktop Infrastructure... 5 Upgrades... 5 Remote Office / Branch Office... 5 Stretched Cluster... 7

More information

INTEL NEXT GENERATION TECHNOLOGY - POWERING NEW PERFORMANCE LEVELS

INTEL NEXT GENERATION TECHNOLOGY - POWERING NEW PERFORMANCE LEVELS INTEL NEXT GENERATION TECHNOLOGY - POWERING NEW PERFORMANCE LEVELS Russ Fellows Enabling you to make the best technology decisions July 2017 EXECUTIVE OVERVIEW* The new Intel Xeon Scalable platform is

More information

A Micron Reference Architecture. Micron Accelerated All-Flash NVMe and SATA vsan 6.6 Solution. Reference Architecture

A Micron Reference Architecture. Micron Accelerated All-Flash NVMe and SATA vsan 6.6 Solution. Reference Architecture Micron Accelerated All-Flash NVMe and SATA vsan 6.6 Solution Reference Architecture Contents Executive Summary... 3 Why Micron for this Solution... 3 Solution Overview... 4 Design Overview... 6 Software...

More information

Micron Accelerated All-Flash VMware vsan 6.6 on HPE ProLiant DL380 Gen10 Server Solution

Micron Accelerated All-Flash VMware vsan 6.6 on HPE ProLiant DL380 Gen10 Server Solution Micron Accelerated All-Flash VMware vsan 6.6 on HPE ProLiant DL380 Gen10 Server Solution Reference Architecture Contents Executive Summary... 3 The Purpose of This Document... 3 Solution Overview... 4

More information

Emulex LPe16000B 16Gb Fibre Channel HBA Evaluation

Emulex LPe16000B 16Gb Fibre Channel HBA Evaluation Demartek Emulex LPe16000B 16Gb Fibre Channel HBA Evaluation Evaluation report prepared under contract with Emulex Executive Summary The computing industry is experiencing an increasing demand for storage

More information

Condusiv s V-locity VM Accelerates Exchange 2010 over 60% on Virtual Machines without Additional Hardware

Condusiv s V-locity VM Accelerates Exchange 2010 over 60% on Virtual Machines without Additional Hardware openbench Labs Executive Briefing: March 13, 2013 Condusiv s V-locity VM Accelerates Exchange 2010 over 60% on Virtual Machines without Additional Hardware Optimizing I/O for Increased Throughput and Reduced

More information

Micron Accelerated All-Flash SATA vsan 6.7 Solution

Micron Accelerated All-Flash SATA vsan 6.7 Solution Micron Accelerated All-Flash SATA vsan 6.7 Solution Reference Architecture Collin Murphy, Storage Solutions Engineer Doug Rollins, Principal Technical Marketing Engineer Contents Executive Summary... 3

More information

Disclaimer This presentation may contain product features that are currently under development. This overview of new technology represents no commitme

Disclaimer This presentation may contain product features that are currently under development. This overview of new technology represents no commitme STO2591BU Amplifying VMware vsan Performance: A Deep Dive into Testing and Tuning (with Lessons Learned) by Western Digital Jonathan Flynn Virtualization Technologist, Western Digital Twitter: @levelrage

More information

SolidFire and Ceph Architectural Comparison

SolidFire and Ceph Architectural Comparison The All-Flash Array Built for the Next Generation Data Center SolidFire and Ceph Architectural Comparison July 2014 Overview When comparing the architecture for Ceph and SolidFire, it is clear that both

More information

Take control of storage performance

Take control of storage performance Take control of storage performance Transition From Speed To Management SSD + RAID 2008-2011 Reduce time to market Inherent bottlenecks Re-architect for better performance NVMe, SCSI Express Reads & Writes

More information

VMware Virtual SAN. High Performance Scalable Storage Architecture VMware Inc. All rights reserved.

VMware Virtual SAN. High Performance Scalable Storage Architecture VMware Inc. All rights reserved. VMware Virtual SAN High Performance Scalable Storage Architecture 2014 VMware Inc. All rights reserved. Agenda Importance of Software Defined approach for Storage Introduction VMware Virtual SAN Key Properties

More information

IBM Emulex 16Gb Fibre Channel HBA Evaluation

IBM Emulex 16Gb Fibre Channel HBA Evaluation IBM Emulex 16Gb Fibre Channel HBA Evaluation Evaluation report prepared under contract with Emulex Executive Summary The computing industry is experiencing an increasing demand for storage performance

More information

VMware Virtual SAN. Technical Walkthrough. Massimiliano Moschini Brand Specialist VCI - vexpert VMware Inc. All rights reserved.

VMware Virtual SAN. Technical Walkthrough. Massimiliano Moschini Brand Specialist VCI - vexpert VMware Inc. All rights reserved. VMware Virtual SAN Technical Walkthrough Massimiliano Moschini Brand Specialist VCI - vexpert 2014 VMware Inc. All rights reserved. VMware Storage Innovations VI 3.x VMFS Snapshots Storage vmotion NAS

More information

Deploy a High-Performance Database Solution: Cisco UCS B420 M4 Blade Server with Fusion iomemory PX600 Using Oracle Database 12c

Deploy a High-Performance Database Solution: Cisco UCS B420 M4 Blade Server with Fusion iomemory PX600 Using Oracle Database 12c White Paper Deploy a High-Performance Database Solution: Cisco UCS B420 M4 Blade Server with Fusion iomemory PX600 Using Oracle Database 12c What You Will Learn This document demonstrates the benefits

More information

XenApp and XenDesktop 7.12 on vsan 6.5 All-Flash January 08, 2018

XenApp and XenDesktop 7.12 on vsan 6.5 All-Flash January 08, 2018 XenApp and XenDesktop 7.12 on vsan 6.5 All-Flash January 08, 2018 1 Table of Contents 1. Executive Summary 1.1.Business Case 1.2.Key Results 2. Introduction 2.1.Scope 2.2.Audience 3. Technology Overview

More information

The HP 3PAR Get Virtual Guarantee Program

The HP 3PAR Get Virtual Guarantee Program Get Virtual Guarantee Internal White Paper The HP 3PAR Get Virtual Guarantee Program Help your customers increase server virtualization efficiency with HP 3PAR Storage HP Restricted. For HP and Channel

More information

VSAN Virtual Desktop Infrastructure Workload First Published On: Last Updated On:

VSAN Virtual Desktop Infrastructure Workload First Published On: Last Updated On: VSAN 6.2 - Virtual Desktop Infrastructure Workload First Published On: 07-20-2016 Last Updated On: 07-20-2016 1 Table of Contents 1. Executive Summary 1.1.Executive Summary 2. Introduction 2.1.Overview

More information

Building Your Own Robust and Powerful Software Defined Storage with VMware vsan. Tips on Choosing Hardware for vsan Deployment

Building Your Own Robust and Powerful Software Defined Storage with VMware vsan. Tips on Choosing Hardware for vsan Deployment Building Your Own Robust and Powerful Software Defined Storage with VMware vsan Tips on Choosing Hardware for vsan Deployment Agenda 1 Overview of VSAN 2 VSAN VCG at a Glance 3 VSAN Hardware Guidance (Ready

More information

Reasons to Deploy Oracle on EMC Symmetrix VMAX

Reasons to Deploy Oracle on EMC Symmetrix VMAX Enterprises are under growing urgency to optimize the efficiency of their Oracle databases. IT decision-makers and business leaders are constantly pushing the boundaries of their infrastructures and applications

More information

ProphetStor DiskProphet Ensures SLA for VMware vsan

ProphetStor DiskProphet Ensures SLA for VMware vsan ProphetStor DiskProphet Ensures SLA for VMware vsan 2017 ProphetStor Data Services, Inc. 0 ProphetStor DiskProphet Ensures SLA for VMware vsan Table of Contents Summary... 2 The Challenges... 2 SLA Compliance...

More information

Delivering HCI with VMware vsan and Cisco UCS

Delivering HCI with VMware vsan and Cisco UCS BRKPAR-2447 Delivering HCI with VMware vsan and Cisco UCS Bhumik Patel Director, Technical Alliances, VMware bhumikp@vmware.com 2 Blistering Pace of vsan Adoption Fastest since ESX 10,000 Customers $300M

More information

vsan Stretched Cluster & 2 Node Guide January 26, 2018

vsan Stretched Cluster & 2 Node Guide January 26, 2018 vsan Stretched Cluster & 2 Node Guide January 26, 2018 1 Table of Contents 1. Overview 1.1.Introduction 2. Support Statements 2.1.vSphere Versions 2.2.vSphere & vsan 2.3.Hybrid and All-Flash Support 2.4.On-disk

More information

How Architecture Design Can Lower Hyperconverged Infrastructure (HCI) Total Cost of Ownership (TCO)

How Architecture Design Can Lower Hyperconverged Infrastructure (HCI) Total Cost of Ownership (TCO) Economic Insight Paper How Architecture Design Can Lower Hyperconverged Infrastructure (HCI) Total Cost of Ownership (TCO) By Eric Slack, Sr. Analyst December 2017 Enabling you to make the best technology

More information

Extreme Storage Performance with exflash DIMM and AMPS

Extreme Storage Performance with exflash DIMM and AMPS Extreme Storage Performance with exflash DIMM and AMPS 214 by 6East Technologies, Inc. and Lenovo Corporation All trademarks or registered trademarks mentioned here are the property of their respective

More information

What's New in VMware vsan 6.6 First Published On: Last Updated On:

What's New in VMware vsan 6.6 First Published On: Last Updated On: First Published On: 04-10-2017 Last Updated On: 11-28-2018 1 Table Of Contents 1. Introduction 1.1.Enterprise-Class Storage for HCI 2. Security 2.1.Native Encryption 2.2.Compliance 3. Management 3.1.Proactive

More information

Evaluation Report: Improving SQL Server Database Performance with Dot Hill AssuredSAN 4824 Flash Upgrades

Evaluation Report: Improving SQL Server Database Performance with Dot Hill AssuredSAN 4824 Flash Upgrades Evaluation Report: Improving SQL Server Database Performance with Dot Hill AssuredSAN 4824 Flash Upgrades Evaluation report prepared under contract with Dot Hill August 2015 Executive Summary Solid state

More information

NEXGEN N5 PERFORMANCE IN A VIRTUALIZED ENVIRONMENT

NEXGEN N5 PERFORMANCE IN A VIRTUALIZED ENVIRONMENT NEXGEN N5 PERFORMANCE IN A VIRTUALIZED ENVIRONMENT White Paper: NexGen N5 Performance in a Virtualized Environment January 2015 Contents Introduction... 2 Objective... 2 Audience... 2 NexGen N5... 2 Test

More information

Modern hyperconverged infrastructure. Karel Rudišar Systems Engineer, Vmware Inc.

Modern hyperconverged infrastructure. Karel Rudišar Systems Engineer, Vmware Inc. Modern hyperconverged infrastructure Karel Rudišar Systems Engineer, Vmware Inc. 2 What Is Hyper-Converged Infrastructure? - The Ideal Architecture for SDDC Management SDDC Compute Networking Storage Simplicity

More information

Reference Architecture: Lenovo Client Virtualization with VMware Horizon and System x Servers

Reference Architecture: Lenovo Client Virtualization with VMware Horizon and System x Servers Reference Architecture: Lenovo Client Virtualization with VMware Horizon and System x Servers Last update: 29 March 2017 Version 1.7 Reference Architecture for VMware Horizon (with View) Contains performance

More information

Fujitsu PRIMEFLEX for VMware vsan 20,000 User Mailbox Exchange 2016 Mailbox Resiliency Storage Solution

Fujitsu PRIMEFLEX for VMware vsan 20,000 User Mailbox Exchange 2016 Mailbox Resiliency Storage Solution Fujitsu PRIMEFLEX for VMware vsan 20,000 User Mailbox Exchange 2016 Mailbox Resiliency Storage Solution Tested with: ESRP Storage Version 4.0 Tested Date: 2018-09-10 Content Content... 2 Overview... 3

More information

Storage Strategies for vsphere 5.5 users

Storage Strategies for vsphere 5.5 users Storage Strategies for vsphere 5.5 users Silverton Consulting, Inc. StorInt Briefing 2 Introduction VMware vsphere is the number one hypervisor solution in the world with more than 500,000 customers worldwide.

More information

VMWARE VIRTUAL SAN: ENTERPRISE-GRADE STORAGE FOR HYPER- CONVERGED INFRASTRUCTURES CHRISTOS KARAMANOLIS RAWLINSON RIVERA

VMWARE VIRTUAL SAN: ENTERPRISE-GRADE STORAGE FOR HYPER- CONVERGED INFRASTRUCTURES CHRISTOS KARAMANOLIS RAWLINSON RIVERA VMWARE VIRTUAL SAN: ENTERPRISE-GRADE STORAGE FOR HYPER- CONVERGED INFRASTRUCTURES CHRISTOS KARAMANOLIS RAWLINSON RIVERA Copyright 2016 EMC Corporation. All rights reserved. 2 Agenda 1 Virtual SAN Overview

More information

Copyright 2013 EMC Corporation. All rights reserved. FLASH NEXT: Zero to One Million IOPs In A Flash

Copyright 2013 EMC Corporation. All rights reserved. FLASH NEXT: Zero to One Million IOPs In A Flash 1 FLASH NEXT: Zero to One Million IOPs In A Flash 2 Expectations Are Reset Forever 3 DATA IS GROWING 4 While At The Same Time Costs Must Be Contained Information Must Become An Asset Performance Must Be

More information

vsan Health Check Improvements First Published On: Last Updated On:

vsan Health Check Improvements First Published On: Last Updated On: vsan Health Check Improvements First Published On: 03-29-2017 Last Updated On: 05-02-2018 1 Table of Contents 1. Health Check and Performance Improvements 1.1.Online Health Check 1.2.Performance Diagnostics

More information

VMware vsan 6.7 Technical Overview First Published On: Last Updated On:

VMware vsan 6.7 Technical Overview First Published On: Last Updated On: VMware vsan 6.7 Technical Overview First Published On: 04-17-2018 Last Updated On: 04-27-2018 1 Table of Contents 1. Introduction 1.1.Enterprise-Class Storage for HCI 2. Architecture 2.1.Servers with Local

More information

Evaluation Report: HP StoreFabric SN1000E 16Gb Fibre Channel HBA

Evaluation Report: HP StoreFabric SN1000E 16Gb Fibre Channel HBA Evaluation Report: HP StoreFabric SN1000E 16Gb Fibre Channel HBA Evaluation report prepared under contract with HP Executive Summary The computing industry is experiencing an increasing demand for storage

More information

SolidFire and Pure Storage Architectural Comparison

SolidFire and Pure Storage Architectural Comparison The All-Flash Array Built for the Next Generation Data Center SolidFire and Pure Storage Architectural Comparison June 2014 This document includes general information about Pure Storage architecture as

More information

The next step in Software-Defined Storage with Virtual SAN

The next step in Software-Defined Storage with Virtual SAN The next step in Software-Defined Storage with Virtual SAN Osama I. Al-Dosary VMware vforum, 2014 2014 VMware Inc. All rights reserved. Agenda Virtual SAN s Place in the SDDC Overview Features and Benefits

More information

VMware vsan Design and Sizing Guide First Published On: February 21, 2017 Last Updated On: April 04, 2018

VMware vsan Design and Sizing Guide First Published On: February 21, 2017 Last Updated On: April 04, 2018 VMware vsan Design and Sizing Guide First Published On: February 21, 2017 Last Updated On: April 04, 2018 1 Table of Contents 1. Introduction 1.1.Overview 2. vsan Design Overview 2.1.Adhere to the VMware

More information

WHITE PAPER. Optimizing Virtual Platform Disk Performance

WHITE PAPER. Optimizing Virtual Platform Disk Performance WHITE PAPER Optimizing Virtual Platform Disk Performance Optimizing Virtual Platform Disk Performance 1 The intensified demand for IT network efficiency and lower operating costs has been driving the phenomenal

More information

Configuring Short RPO with Actifio StreamSnap and Dedup-Async Replication

Configuring Short RPO with Actifio StreamSnap and Dedup-Async Replication CDS and Sky Tech Brief Configuring Short RPO with Actifio StreamSnap and Dedup-Async Replication Actifio recommends using Dedup-Async Replication (DAR) for RPO of 4 hours or more and using StreamSnap for

More information

Administering VMware Virtual SAN. Modified on October 4, 2017 VMware vsphere 6.0 VMware vsan 6.2

Administering VMware Virtual SAN. Modified on October 4, 2017 VMware vsphere 6.0 VMware vsan 6.2 Administering VMware Virtual SAN Modified on October 4, 2017 VMware vsphere 6.0 VMware vsan 6.2 You can find the most up-to-date technical documentation on the VMware website at: https://docs.vmware.com/

More information

Benefits of Automatic Data Tiering in OLTP Database Environments with Dell EqualLogic Hybrid Arrays

Benefits of Automatic Data Tiering in OLTP Database Environments with Dell EqualLogic Hybrid Arrays TECHNICAL REPORT: Performance Study Benefits of Automatic Data Tiering in OLTP Database Environments with Dell EqualLogic Hybrid Arrays ABSTRACT The Dell EqualLogic hybrid arrays PS6010XVS and PS6000XVS

More information

Virtualized SQL Server Performance and Scaling on Dell EMC XC Series Web-Scale Hyper-converged Appliances Powered by Nutanix Software

Virtualized SQL Server Performance and Scaling on Dell EMC XC Series Web-Scale Hyper-converged Appliances Powered by Nutanix Software Virtualized SQL Server Performance and Scaling on Dell EMC XC Series Web-Scale Hyper-converged Appliances Powered by Nutanix Software Dell EMC Engineering January 2017 A Dell EMC Technical White Paper

More information

2014 VMware Inc. All rights reserved.

2014 VMware Inc. All rights reserved. 2014 VMware Inc. All rights reserved. Agenda Virtual SAN 1 Why VSAN Software Defined Storage 2 Introducing Virtual SAN 3 Hardware Requirements 4 DEMO 5 Questions 2 The Software-Defined Data Center Expand

More information

Hedvig as backup target for Veeam

Hedvig as backup target for Veeam Hedvig as backup target for Veeam Solution Whitepaper Version 1.0 April 2018 Table of contents Executive overview... 3 Introduction... 3 Solution components... 4 Hedvig... 4 Hedvig Virtual Disk (vdisk)...

More information

IOmark-VM. VMware VSAN Intel Servers + VMware VSAN Storage SW Test Report: VM-HC a Test Report Date: 16, August

IOmark-VM. VMware VSAN Intel Servers + VMware VSAN Storage SW Test Report: VM-HC a Test Report Date: 16, August IOmark-VM VMware VSAN Intel Servers + VMware VSAN Storage SW Test Report: VM-HC-160816-a Test Report Date: 16, August 2016 Copyright 2010-2016 Evaluator Group, Inc. All rights reserved. IOmark-VM, IOmark-VDI,

More information

vrealize Operations Management Pack for vsan 1.0 Guide

vrealize Operations Management Pack for vsan 1.0 Guide vrealize Operations Management Pack for vsan 1.0 Guide This document supports the version of each product listed and supports all subsequent versions until the document is replaced by a new edition. To

More information

Managing Performance Variance of Applications Using Storage I/O Control

Managing Performance Variance of Applications Using Storage I/O Control Performance Study Managing Performance Variance of Applications Using Storage I/O Control VMware vsphere 4.1 Application performance can be impacted when servers contend for I/O resources in a shared storage

More information

Increasing Performance of Existing Oracle RAC up to 10X

Increasing Performance of Existing Oracle RAC up to 10X Increasing Performance of Existing Oracle RAC up to 10X Prasad Pammidimukkala www.gridironsystems.com 1 The Problem Data can be both Big and Fast Processing large datasets creates high bandwidth demand

More information

Why Datrium DVX is Best for VDI

Why Datrium DVX is Best for VDI Why Datrium DVX is Best for VDI 385 Moffett Park Dr. Sunnyvale, CA 94089 844-478-8349 www.datrium.com Technical Report Introduction Managing a robust and growing virtual desktop infrastructure in current

More information

DELL EMC VXRAIL TM APPLIANCE OPERATIONS GUIDE

DELL EMC VXRAIL TM APPLIANCE OPERATIONS GUIDE DELL EMC VXRAIL TM APPLIANCE OPERATIONS GUIDE A Hyper-Converged Infrastructure Appliance from Dell EMC and VMware PART NUMBER: H16788 ABSTRACT This document describes how to perform day-to-day operations

More information

Administering VMware vsan. Modified on October 4, 2017 VMware vsphere 6.5 VMware vsan 6.6.1

Administering VMware vsan. Modified on October 4, 2017 VMware vsphere 6.5 VMware vsan 6.6.1 Administering VMware vsan Modified on October 4, 2017 VMware vsphere 6.5 VMware vsan 6.6.1 You can find the most up-to-date technical documentation on the VMware website at: https://docs.vmware.com/ If

More information

Considerations to Accurately Measure Solid State Storage Systems

Considerations to Accurately Measure Solid State Storage Systems Considerations to Accurately Measure Solid State Storage Systems PRESENTATION TITLE GOES HERE Leah Schoeb Storage Solutions and Performance Manager Intel Landscape for Solid State Storage Greater Performance

More information

Introducing Tegile. Company Overview. Product Overview. Solutions & Use Cases. Partnering with Tegile

Introducing Tegile. Company Overview. Product Overview. Solutions & Use Cases. Partnering with Tegile Tegile Systems 1 Introducing Tegile Company Overview Product Overview Solutions & Use Cases Partnering with Tegile 2 Company Overview Company Overview Te gile - [tey-jile] Tegile = technology + agile Founded

More information

Performance Testing of SQL Server on Kaminario K2 Storage

Performance Testing of SQL Server on Kaminario K2 Storage Performance Testing of SQL Server on Kaminario K2 Storage September 2016 TABLE OF CONTENTS 2 3 5 14 15 17 Executive Summary Introduction to Kaminario K2 Performance Tests for SQL Server Summary Appendix:

More information

VMware vsan 6.0 Performance First Published On: Last Updated On:

VMware vsan 6.0 Performance First Published On: Last Updated On: First Published On: 07-20-2016 Last Updated On: 07-20-2016 1 Table of Contents 1. Executive Summary 1.1.Executive Summary 2. Introduction 2.1.Overview 3. vsan Cluster Setup 3.1.Overview 3.2.Hybrid vsan

More information

Hyper-Convergence De-mystified. Francis O Haire Group Technology Director

Hyper-Convergence De-mystified. Francis O Haire Group Technology Director Hyper-Convergence De-mystified Francis O Haire Group Technology Director The Cloud Era Is Well Underway Rapid Time to Market I deployed my application in five minutes. Fractional IT Consumption I use and

More information

The Impact of SSD Selection on SQL Server Performance. Solution Brief. Understanding the differences in NVMe and SATA SSD throughput

The Impact of SSD Selection on SQL Server Performance. Solution Brief. Understanding the differences in NVMe and SATA SSD throughput Solution Brief The Impact of SSD Selection on SQL Server Performance Understanding the differences in NVMe and SATA SSD throughput 2018, Cloud Evolutions Data gathered by Cloud Evolutions. All product

More information

Infinio Accelerator Product Overview White Paper

Infinio Accelerator Product Overview White Paper Infinio Accelerator Product Overview White Paper November 2015 Table of Contents Executive Summary.3 Disruptive datacenter trends and new storage architectures..3 Separating storage performance from capacity..4

More information

VMware Virtual SAN Technology

VMware Virtual SAN Technology VMware Virtual SAN Technology Today s Agenda 1 Hyper-Converged Infrastructure Architecture & Vmware Virtual SAN Overview 2 Why VMware Hyper-Converged Software? 3 VMware Virtual SAN Advantage Today s Agenda

More information

VxRail: Level Up with New Capabilities and Powers GLOBAL SPONSORS

VxRail: Level Up with New Capabilities and Powers GLOBAL SPONSORS VxRail: Level Up with New Capabilities and Powers GLOBAL SPONSORS VMware customers trust their infrastructure to vsan #1 Leading SDS Vendor >10,000 >100 83% vsan Customers Countries Deployed Critical Apps

More information

Identifying Performance Bottlenecks with Real- World Applications and Flash-Based Storage

Identifying Performance Bottlenecks with Real- World Applications and Flash-Based Storage Identifying Performance Bottlenecks with Real- World Applications and Flash-Based Storage TechTarget Dennis Martin 1 Agenda About Demartek Enterprise Data Center Environments Storage Performance Metrics

More information

SC Series: Performance Best Practices. Brad Spratt Performance Engineering Midrange & Entry Solutions

SC Series: Performance Best Practices. Brad Spratt Performance Engineering Midrange & Entry Solutions SC Series: Performance Best Practices Brad Spratt Performance Engineering Midrange & Entry Solutions What s New with the SC Series New Dell EMC SC5020 Hybrid Array Optimized for Economics and Efficiency

More information

HCI: Hyper-Converged Infrastructure

HCI: Hyper-Converged Infrastructure Key Benefits: Innovative IT solution for high performance, simplicity and low cost Complete solution for IT workloads: compute, storage and networking in a single appliance High performance enabled by

More information

RADICALLY SIMPLE HIGHEST PERFORMANCE LOWEST COST R E ADY FO R ANY APP, ANY SCALE

RADICALLY SIMPLE HIGHEST PERFORMANCE LOWEST COST R E ADY FO R ANY APP, ANY SCALE CHEAT SHEET INTERNAL USE ONLY VMware Virtual SAN Internal and Partner Use Only What is VMware Virtual SAN? VMware Virtual SAN is radically simple, software-defined storage. Seamlessly integrated with VMware

More information