TMM4200/420 DATASHEET

Size: px
Start display at page:

Download "TMM4200/420 DATASHEET"

Transcription

1 TMM4200/420 Marking System General Arrangments System Overview The TMM4200/420 is a high-speed, multi-pin marking system that permanently prints messages into a variety of materials such as steel, aluminum, and plastic. Hardened pins are pneumatically accelerated to indent dot matrix characters into the item being marked. The shape, size, density, and location of characters are determined by the user through the system software. The marking head moves the pin cartridge through X- and Y-axis motions to reach the correct position for each dot of the characters to be marked. The system software automatically controls pneumatic pin extension and retraction to mark the message. The TMM4200 Marking Head includes the mechanical motion components to position the marking pins at precise X/Y positions and the pneumatic components to drive the marking pins from, and return the pins to, the pin cartridge. A shield plate around the pin cartridge assembly helps prevent debris from entering the marking head cavity. The TMM4200 marking head is an X/Y-traversing mechanism. Using two stepper motor drives, it accurately positions the pin cartridge at coordinate-defined locations in marking window within.008mm (in Fine mode) and.032mm (in Standard mode). The TMM4200 uses a rack-and-pinion drive system to rapidly position the pin cartridge and to accommodate the rigorous dynamics of impacting and rebounding. The floating pin design permits consistent, high-quality marks, even on irregular, slightly curved surfaces. It also accommodates applications where marking surfaces cannot be positioned at a consistent distance from the marker. TMM4200 Configurations include a hand-held version and a fixture-mounted version. The hand-held marker is available for portable operation. It incorporates a pistol grip handle with a push button trigger switch and an integral standoff to position the marker against the marking surface. The fixture-mounted unit is available for mounting in a fixed location. Pin Cartridges. The standard system uses non-lubricated, lightweight pin cartridges for the 25S-series and 150SA-series pins. Cartridges for 25S pins are available in two configurations: four (4) pins spaced on 6mm centers or on 12mm centers. The cartridge for 150SA pins contain two (2) pins spaced on 25mm centers. The cartridge configuration dictates the size of the marking window along the X-axis. Refer to the marking head installation drawing for details. Marking Pins. The TMM4200 uses 25S-series and 150SA-series marking pins available in various cone (tip) angles. The 25S-series pins are made of powdered steel or carbide. The 150SA pins are made of powdered steel with carbide tips. Refer to the marking head installation drawing for pin stroke (pin extension) dimensions. The Marker Cable connects the marking head to the controller. The highly flexible cable is 4m (13.1 ft.) long and attaches to the back of the marker with a quick disconnect connector. Optional extension cables lengths are available. The Filter/Regulator Unit includes two regulators with pressure gauges to control drive air and return air. The first regulator contains a filter to help remove contaminants from the supply air. Two air lines connect the regulated air to the marking head. Drive air fires the impact pin; return air pushes it back into the cartridge. Standard air lines are 4m (13.1 ft.) long made of 6mm tubing. TMC420 Controller includes an integrated keyboard with a four line LCD display. It provides the electrical interface and software control of the TMM4200 marking head. (Refer to TMC420 Controller Specifications for details.) Doc. No Rev. C 1 of 7

2 TMM4200 Hand-held Detail Drawing System Setup 1. Fixture-mounted markers only. When designing a fixture, allow for 3-axis adjustment to aid in horizontal, vertical, and lateral alignment of the marking head. Mount marking head to a suitable fixture using four M bolts. Mounting bolts must not extend into marking head more than 10mm (0.39 in.). 2. Mount filter/regulator assembly, using brackets provided, within 4m (13.1 ft.) of marking head. 3. Connect drive air and return air lines to the connectors on back of marking head. 4. Connect supply air to input port on filter/regulator assembly. 5. Adjust drive air and return air for proper pin impact depth. Nominal drive air pressure 5.5 bars (80 psi) Nominal return air pressure 1.5 bars (20 psi) 6. Adjust pin stroke for proper pin impact depth. 7. Locate controller as close as practical to marking head. Standard marker cable length is 4m (13.1 ft.). Note: The TMC420 is not a sealed unit. Protect it from potentially damaging conditions; do not block case vents. 8. Ensure controller power switch (on back panel) is OFF; connect power cable to controller. 9. Connect marker cable to controller; tighten securely. 10. Position controller power switch to ON (on back panel) to start the system software. System Options Optional Custom Cartridges (pin quantity and spacing) Marking Head Extension Cables TMC420 Controller Mounting Bracket Kit Bar Code Scanner Bar Code Wand Backup Utility Software Upgrade Utility Software Logo/Font Generator Software Doc. No Rev. C 2 of 7

3 TMM4200 Fixture Mounted Detail Drawing TMM4200 Marking Head Specifications DIMENSIONS see illustrations RATING NEMA 2 (I.P. 41) HAND-HELD: 2.06 kg (4.54 lb) excluding marker cable, and pin cartridge FIXTURED: 1.59 kg (3.50 lb) excluding marker cable, pin cartridge, handle, standoff, and tooling OPERATING TEMP. 0 to 50 C (32 to 122 F), non-condensing AIR SUPPLY Clean and dry, 4.2 to 8.3 bars (60 to 120 psi) AIR CONSUMPTION 0.15 L/sec (0.32 SCFM) idle 0.28 L/sec (0.60 SCFM) marking MARKING AREA PIN TYPES PIN MATERIAL see illustrations 25S-series, various cone (tip) angles 150SA-series, various cone (tip) angles Powdered Steel or Carbide (25S-series) Powdered Steel w/ Carbide Tip (150SA-series) Marking Characteristics. The TMM4200 can produce characters as small as 0.75mm (0.03 in.) high. Text strings may be rotated 180 to print inverted. Characters can printed with resolutions from 4 to 79 dots/cm (10 to 200 dots/in.) for an engraved look. The depth of mark can be adjusted over a significant range by adjusting the pin stroke and, to a lesser extent, by adjusting the drive air pressure. Three marking modes are available to optimize quality and speed. Raster mode prints side-to-side, indexing downward one row at a time. Matrix mode prints up and down, indexing one column at a time. Continuous mode prints with only one pin at a time tracing the character shape. Marking Speeds. The system is capable of marking eight (8) characters per second (two characters per pin per second) using a four-pin cartridge to print 3mm (0.118 in.) high characters in the 5x7 font. Speeds will vary widely depending on the selected character size, style, and dot density. Specific times can be verified by a Telesis representative. Marking Noise. Although every attempt is made to reduce noise, the material being marked significantly influences the noise level. For example, marking a solid lead block produces less noise than marking a thin-walled steel pipe. Pin Life. Pin life depends largely on the type of material being marked, how hard or abrasive it is, and the required marking depth. On typical metals with a hardness of Rockwell Rb47, marking at a depth of.127mm (0.005 in.), powdered steel pins average about 3 million impressions before needing sharpened. Doc. No Rev. C 3 of 7

4 TMC420 Mounting Drawing TMC420 Controller Configurations. Three models of the TMC420 are available for use with the TMM4200: the TMC420 table-top controller, the TMC420P panel-mounted controller, and the TMC420N enclosure-mounted controller. All controllers provide the same software features and the same connectivity for external communications. Differences occur only in their mounting configurations. TMC420 Specifications DIMENSIONS refer to TMC420 Mounting Drawing RATING NEMA 1 (I.P. 30) OPERATING TEMP. POWER I/O VOLTAGE 2.15 kg (4.75 lb.) 0 to 50 C (32 to 122 F), non-condensing VAC, 2 amps, Hz single phase VAC, 1 amp, Hz single phase 12 to 24 VDC (customer-supplied) TMC420P Specifications DIMENSIONS refer to TMC420P Mounting Drawing RATING NEMA 1 (I.P. 30) stand-alone NEMA 12 (I.P. 65) installed OPERATING TEMP. POWER I/O VOLTAGE 3.10 kg (6.8 lb.) 0 to 50 C (32 to 122 F), non-condensing VAC, 2 amps, Hz single phase VAC, 1 amp, Hz single phase 12 to 24 VDC (customer-supplied) TMC420N Specifications DIMENSIONS refer to TMC420N Mounting Drawing RATING NEMA 12 (I.P. 65) OPERATING TEMP. POWER I/O VOLTAGE kg (28.1 lb.) 0 to 50 C (32 to 122 F), non-condensing VAC, 2 amps, Hz single phase VAC, 1 amp, Hz single phase 12 to 24 VDC (customer-supplied) Doc. No Rev. C 4 of 7

5 TMC420P Mounting Drawing Interface Panel. The interface panel provides various ports for connecting the marker, host computers, logic controllers, or optional accessories. System Software. The system software is permanently installed in the controller. It provides the user interface for the operator to control the marker. The software also provides a library for storing, loading, and editing user-defined patterns. Patterns are files stored in the controller s memory. The controller can store up to 75 patterns. Each pattern contains one or more fields. A field defines a single object and how it will be printed. Fields may define text strings, 2D data matrix symbols, Goto commands, or Pause commands. Text fields may include alphanumeric characters, symbols, and special message flags. The message flags automatically insert data into the text string, such as serial numbers, times, and dates. I/O Control Signals. The TMC420 is configured for DC I/O only. The TTL I/O Port may be used to connect a remote pushbutton control for Start Print and Abort commands. The I/O Port may be used to connect a PLC or other DC I/O source. The I/O Port allows remote control of pattern selection, printing, aborting, placing the marker online, and monitoring of the Ready and Done output signals. Cable connectors and connector pins are supplied with the controller for constructing appropriate interface cables. START PRINT Input signal, begins print cycle SEL_0, 1, 2, 3 * Input signals, remote pattern selection (15* max.) SEL_3 * ABORT INPUT COMM READY DONE Input signal, marker online Input signal, aborts print cycle For all inputs (+ or supply) Output signal, ready for message or start print Output signal, print cycle complete OUTPUT COMM For all outputs (+ or supply) * System software allows SEL_3 signal to be configured for remotely selecting patterns or for remotely placing the marker online. If used for marker online, pattern selection is reduced to 7 patterns (max). Doc. No Rev. C 5 of 7

6 TMC420N Mounting Drawing Serial Interface. The Host Port is used for RS-232 and RS-485 communications with serial devices such as a host computer or bar code scanner. Up to 31 controllers may be used in a multi-drop configuration using the RS-485 interface. The host computer can load patterns, download messages, place the marker on/offline, and monitor system errors. (See Serial Communications for details.) Serial Communications. The Host Port may be used for either RS-232 or RS-485 communication. The RS-232 interface is most often used with remote devices such as bar code readers or host computers. The RS-485 interface is normally used for long transmission distances or multi-drop networks of up to 31 TMC420 controllers. The serial port may be configured to communicate using either the Telesis Programmable Protocol or Telesis Extended Protocol. The following describes the serial data character format on all transmissions to and from the TMC420 controller. Asynchronous 1200, 2400, 4800, 9600, or baud-host One Start Bit One or Two Stop Bit(s) Seven or Eight Data Bits None, Even or Odd Parity Doc. No Rev. C 6 of 7

7 Programmable Protocol is used where very simple one-way communications are required (such as with bar code scanners). Programmable Protocol provides no error checking or acknowledgment of the transmitted data. Note that XON/XOFF Protocol applies even when Programmable Protocol is selected. Starting Character specifies where the software begins to count character positions. This number must be entered in ASCII decimal format such as 2 for STX. Terminating Character identifies the end of transmitted string (usually ASCII carriage return character, decimal 13). Character Position counted from the starting character ignoring all characters preceding it. Character Length accepts variable length messages (if set to 0) or messages of a pre-specified, fixed number of characters. Ignore Character identifies the character to ignore when sent from the host (usually ASCII line feed character, decimal 10) Message Type allows message-type recognition which defines how the marking system will use data it receives from the host.. P loads a specific pattern identified by data extracted from host V updates first variable text field with data extracted from host 1 overwrites first text field with data extracted from the host Q updates text in first query buffer with data extracted from host 0 indicates that host will provide message type, field number (if applicable), and data; delegates message type selection to the host on message-by-message basis. The host message must use the format Tnn<string> where: T = P, V, 1, or Q to indicate the message type. nn = two-digit number to indicate field number or query text buffer where data will be placed. Note that a number is not used with Message Type P. <string> = pattern name (Message Type P) or field data (Message Types V, 1, or Q), as applicable. Extended Protocol includes error checking and transmission acknowledgment. It should be used in applications where serial communication is a vital part of the marking operation. Extended Protocol must be used in multi-drop applications. All communications are carried out in a master-slave relationship with the host being the master. Only the master has the ability to initiate communications. If the host does not receive a response within three seconds, it should re-transmit its original message. If no response is received after three tries, it should declare the link to be down. The following describes the message format as sent from the master to the TMC420 controller. SOH TYPE [##] STX [DATA TEXT] ETX BCC CR SOH ASCII Start of Header character (001H). The controller ignores all characters received prior to the SOH. TYPE A single, printable ASCII character that defines the meaning (type) and content of the message downloaded from the host, where: 1 overwrites the specified field of currently loaded pattern, using the format 1nn<string> where nn is the field number. V updates specified variable text field of currently loaded pattern, using the format Vnn<string> where nn is the field number. Q updates specified query buffer with the data received from host, using the format Qnn<string> where nn is the buffer number. P specifies pattern name to be loaded for printing O resets marker and places it online G initiates a print cycle to mark the currently loaded pattern I requests the marker output status; returns a single-digit hexadecimal value to report state of READY and DONE: Returned Value DONE READY 0 off Off 1 off ON 2 ON Off 3 ON ON S requests the marker error status; returns a value that represents a particular type of error: Returned Value 0x0000 0x0001 0x0002 0x0004 0x0008 0x0010 0x0020 0x0080 0x0100 0x0200 TYPE OF ERROR (no error) ONLINE_ERROR PATTERN_LOAD_ERROR DISALLOWED_NO_PATTERN DISALLOWED_OFFLINE PATTERN_FIELD_ERROR MARKER_ABORTED_ERROR PIX_OUT_OF_RANGE_ERROR RAM_ERROR SN_RANGE_ERROR [##] Two optional ASCII decimal digits that specify the Station ID number for use in multi-drop network applications. The ID may range from Note that 00 is reserved for applications where only one controller is used. In such applications, this field may be eliminated and 00 will be assumed. STX ASCII Start of Text Character (002H). [DATA TEXT] Optional field that may be required for certain message types. ETX ASCII end of text character (003H). BCC Optional Block Check Code that is generated and sent to improve link reliability by providing fault detection. The BCC is calculated by taking an eight bit addition of the TYPE and DATA TEXT characters and transmitting them as a three digit ASCII decimal number in the range from 000 to 255. If the sum is greater than 255, the most significant bit overflows and is discarded. CR ASCII Carriage Return Character (00DH). Doc. No Rev. C 7 of 7

TMM5400/420 DATASHEET

TMM5400/420 DATASHEET TMM5400/420 Marking System General Arrangement Drawing System Overview The Telesis TMM5400/420 PINSTAMP is a high-speed, multipin marking system that permanently prints messages into a variety of materials

More information

TMP4210/420 Marking System

TMP4210/420 Marking System TMP4210/420 Marking System General Arrangments System Overview The Telesis TMP4210/420 PINSTAMP is a high-speed, singlepin marking system that permanently prints messages into a variety of materials such

More information

TMP1700E/420 DATASHEET

TMP1700E/420 DATASHEET TMP1700E/420 Marking System General Arrangement System Overview The Telesis TMP1700E/420 PINSTAMP marking system permanently prints messages into a variety of materials such as steel, aluminum, and plastic.

More information

TMP3200E/420 DATASHEET

TMP3200E/420 DATASHEET TMP3200E/420 Marking System General Arrangement System Overview The Telesis TMP3200E/420 PINSTAMP marking system permanently prints messages into a variety of materials such as steel, aluminum, and plastic.

More information

TMM5100/420 DATASHEET

TMM5100/420 DATASHEET System Overview The Telesis TMM5100/420 PINSTAMP marking system permanently prints messages into a variety of materials such as steel, aluminum, and plastic. Hardened pins are pneumatically accelerated

More information

TMP3200/090 DATASHEET

TMP3200/090 DATASHEET TMP3200/090 Marking System General Arrangement System Overview The TMP3200/090 marking system permanently prints messages into a variety of materials such as steel, aluminum, and plastic. A hardened pin

More information

TMM5400/470 Marking Systems

TMM5400/470 Marking Systems TMM5400/470 Marking System General Arrangements SYSTEM OVERVIEW The Telesis TMM5400/470 PINSTAMP is a high-speed, multi-pin marking system that permanently prints messages into a variety of materials such

More information

TMM4250/470 Marking System

TMM4250/470 Marking System TMM4250/470 Marking System General Arrangement SYSTEM OVERVIEW The Telesis TMM4250/470 PINSTAMP is a high-speed, multipin marking system that permanently prints messages into a variety of materials such

More information

BenchMark 320 Datasheet

BenchMark 320 Datasheet BenchMark320 Marking System General Arrangement System Overview The Telesis BenchMark 320 marking system permanently prints messages into a variety of materials such as steel, aluminum, and plastic. An

More information

DPP2000/420 DATASHEET

DPP2000/420 DATASHEET DPP2000/420 General Arrangement Drawing System Overview The DPP2000 is a fully programmable, data plate (tag) printer that automatically extracts data plates from a magazine and positions them before a

More information

TMM4215/470 Marking System

TMM4215/470 Marking System TMM4215/470 Marking System General Arrangements SYSTEM OVERVIEW The Telesis PINSTAMP TMM4215/470 is a high-speed, multi-pin marking system that permanently prints messages into a variety of materials such

More information

TMP4750/470 Marking System

TMP4750/470 Marking System TMP4750/470 Marking System General Arrangements SYSTEM OVERVIEW The Telesis Pinstamp TMP4750/470 is a high-speed, single-pin marking system that permanently prints messages into a variety of materials

More information

TMP2100/600 Marking System

TMP2100/600 Marking System TMP2100/600 Marking System General Arrangements SYSTEM OVERVIEW The Telesis Pinstamp TMP2100/600 is a high-speed, single-pin marking system that permanently prints messages into a variety of materials

More information

Custom TMM7200/470 Marking Systems

Custom TMM7200/470 Marking Systems TMM7200/470 Marking System General Arrangement SYSTEM OVERVIEW The Telesis TMM7200/470 PINSTAMP marking system permanently prints messages into a variety of materials such as steel, aluminum, and plastic.

More information

TMP7000/470 Marking System

TMP7000/470 Marking System TMP7000/470 Marking System General Arrangement Drawing SYSTEM OVERVIEW The Telesis TMP7000/470 PINSTAMP marking system permanently prints messages into a variety of materials such as steel, aluminum, and

More information

TMP4210/600 Marking System

TMP4210/600 Marking System TMP4210/600 MARKING SYSTEM GENERAL ARRANGEMENTS SYSTEM OVERVIEW The Telesis Pinstamp TMP4210/600 is a high-speed, singlepin marking system that permanently prints messages into a variety of materials such

More information

BenchMark 200/BM470 Marking System

BenchMark 200/BM470 Marking System BenchMark200/BM470 Marking System General Arrangement SYSTEM OVERVIEW The Telesis BenchMark 200 marking system permanently prints messages into a variety of materials such as steel, aluminum, and plastic.

More information

SC2000/TMC470 Marking System

SC2000/TMC470 Marking System SC2000/470 Marking System General Arrangement SYSTEM OVERVIEW The Telesis SC2000/470 TeleScribe Marking System permanently inscribes messages into a variety of materials such as steel, aluminum, and plastic.

More information

BenchMark 460/BM470 Marking System

BenchMark 460/BM470 Marking System BenchMark460/BM470 Marking System General Arrangement SYSTEM OVERVIEW The Telesis BenchMark 460 marking system permanently prints messages into a variety of materials such as steel, aluminum, and plastic.

More information

TMP1700/TMC600 Marking System

TMP1700/TMC600 Marking System TMP1700/TMC600 Marking System General Arrangement SYSTEM OVERVIEW The Telesis TMP1700/TMC600 PINSTAMP marking system permanently prints messages into a variety of materials such as steel, aluminum, and

More information

TMP1700/470 Marking System

TMP1700/470 Marking System TMP1700/470 Marking System General Arrangement SYSTEM OVERVIEW The Telesis TMP1700/470 PINSTAMP marking system permanently prints messages into a variety of materials such as steel, aluminum, and plastic.

More information

NOMAD 4000 Marking System

NOMAD 4000 Marking System Nomad 4000 Marking System General Arrangement SYSTEM OVERVIEW The Telesis NOMAD 4000 marking system permanently prints messages into a variety of materials such as steel, aluminum, and plastic. A hardened

More information

ADP Dot Peen Marking Machine

ADP Dot Peen Marking Machine ADP25120- Dot Peen Marking Machine Marking area 25x120mm 1x4.6" Air supply/filter Drive Air Marking head Controller Benchtop Mode Handheld Mode Power supply High quality at higher speed Extremely precise

More information

ADP Dot Peen Marking Machine

ADP Dot Peen Marking Machine ADP120160- Dot Peen Marking Machine Marking area 120160mm 4.7x6.3" Air supply/filter Drive Air Marking head Controller Benchtop Mode Power supply Handheld Mode High quality at higher speed Extremely precise

More information

FQ20 Laser Marking System

FQ20 Laser Marking System FQ20 Laser Marking System General Arrangement SYSTEM OVERVIEW The Telesis FQ20 is one laser in a family of maintenance-free, Q-switched, Ytterbium fiber lasers designed for marking applications. These

More information

FQ30DS Laser Marking System

FQ30DS Laser Marking System FQ30DS Laser Marking System General Arrangement SYSTEM OVERVIEW The Telesis FQ30DS is one laser in a family of maintenancefree, Q-switched, Ytterbium fiber lasers designed for marking applications. These

More information

EVC Laser Marking System

EVC Laser Marking System EVC Laser Marking System General Arrangement SYSTEM OVERVIEW The Telesis EVC is an advanced, fiber-coupled diode-pumped solid state (DPSS) laser marking system. The laser beam and Q-switched pulse characteristics

More information

CO30AP Laser Marking System

CO30AP Laser Marking System CO30AP Laser Marking System General Arrangements SYSTEM OVERVIEW The Telesis CO30AP is a 30-watt, RF-excited, continuous wave, sealed-tube, CO 2 laser marking system that provides a galvo-steered beam

More information

FQ2H-series/F16I/F16IE/F16SP Laser Marking Systems

FQ2H-series/F16I/F16IE/F16SP Laser Marking Systems F-series/F16I/F16IE/ F16SP Laser Marking System General Arrangement SYSTEM OVERVIEW The Telesis F-series lasers are a family of maintenance-free, Q-switched, Ytterbium fiber lasers designed for marking

More information

F-series/F14A/F14SP Laser Marking Systems

F-series/F14A/F14SP Laser Marking Systems F-series/F14A/F14SP Laser Marking Systems F-series/F14A/ F14SP Laser Marking System General Arrangement SYSTEM OVERVIEW The Telesis F-series lasers are a family of maintenance-free, Q-switched, Ytterbium

More information

EV15DS Laser Marking System

EV15DS Laser Marking System SYSTEM OVERVIEW The Telesis EV15DS is an advanced, fiber-coupled diode pumped solid state (DPSS) laser marking system. The laser beam and Q-switched pulse characteristics are optimized for applications

More information

EY6DS Laser Marking System

EY6DS Laser Marking System SYSTEM OVERVIEW The Telesis EY6DS is an advanced, fiber-coupled diode pumped solid state (DPSS) laser marking system. The laser beam and Q-switched pulse characteristics are optimized for applications

More information

Technical sheet. Page - 1 ADP 5090 AC x90mm, dove il pistoncino si muove lungo gli assi X e Y con una precisione micrometrica.

Technical sheet. Page - 1 ADP 5090 AC x90mm, dove il pistoncino si muove lungo gli assi X e Y con una precisione micrometrica. Page - 1 ADP 5090 AC 500 50x90mm, dove il pistoncino si muove lungo gli assi X e Y con una precisione micrometrica. AD5090 system marks permanently different materials, such as metals, aluminum, iron,

More information

ec1: Column-mounted system

ec1: Column-mounted system ec1: Column-mounted system PRINCIPLE The ec1 column-mounted marking system completes the marking of parts using electromagnetic dot peen technology. This process allows reliable and unalterable marking

More information

EV4GDS Laser Marking System

EV4GDS Laser Marking System SYSTEM OVERVIEW The Telesis EV4GDS is a fiber-coupled, diode-pumped, solid state (DPSS), green wavelength laser marking system. The laser beam and Q-switched pulse characteristics are optimized for applications

More information

EV40 Laser Marking System

EV40 Laser Marking System EV40 Laser Marking System General Arrangements SYSTEM OVERVIEW The Telesis EV40 is an advanced, fiber-coupled diode pumped solid state (DPSS) laser marking system. The laser beam and Q-switched pulse characteristics

More information

E-series/E1015 Laser Marking Systems

E-series/E1015 Laser Marking Systems SYSTEM OVERVIEW The Telesis E-series lasers are advanced diode-pumped solid state (DPSS) laser marking systems. The E-series design features a Q-switched end-pumped laser with a remote fibercoupled diode

More information

E-series/E1140 Laser Marking Systems

E-series/E1140 Laser Marking Systems E-series/E1140 Laser Marking Systems General Arrangements SYSTEM OVERVIEW The Telesis E-series lasers are advanced diode-pumped solid state (DPSS) laser marking systems. The E-series design features a

More information

IS-3000-LS-ABB INFRARED SCANNER

IS-3000-LS-ABB INFRARED SCANNER IS-3000-LS-ABB INFRARED SCANNER NON-CONTACT, RELIABLE, PRECISE, LONG RANGE POSITIONING FOR HOT OR COLD PRODUCTS FEATURES: SIMULATES ORIGINAL ABB PULSE OUTPUT AUTOMATIC GAIN CONTROL ADJUSTABLE SCAN ANGLE

More information

ID8400 Stamper Communications for Firmware Versions 5 and 6

ID8400 Stamper Communications for Firmware Versions 5 and 6 ID8400 Stamper Communications for Firmware Versions 5 and 6 Introduction This document will describe the Extended Protocol Communications as implemented with the ITM8400 marking system software. Extended

More information

Leica LP C (Laser Printer for Cassettes) System Requirement & Specifications

Leica LP C (Laser Printer for Cassettes) System Requirement & Specifications Leica LP C (Laser Printer for Cassettes) System Requirement & Specifications LP C Req. & Spec. Page 1 of 9 Version 1.1 Copyright 2010 Leica Microsystems All rights reserved All company names, product names,

More information

Mounting Dimensions / Viewing 2 Mounting Options 3. Wiring Configuration 4. Quick Set up Procedure 5. Changing Intensity 6.

Mounting Dimensions / Viewing 2 Mounting Options 3. Wiring Configuration 4. Quick Set up Procedure 5. Changing Intensity 6. Section Mounting Dimensions / Viewing 2 Mounting Options 3 Section 2 Wiring Configuration 4 Section 3 Quick Set up Procedure 5 Section 4 Changing Intensity 6 Section 5 Option Summary 7 Section 6 Option

More information

PD1100 STAND-ALONE PROGRAMMING & USER S GUIDE. use the freedom

PD1100 STAND-ALONE PROGRAMMING & USER S GUIDE. use the freedom PD1100 STAND-ALONE ALPHANUMERIC POLE DISPLAY PROGRAMMING & USER S GUIDE use the freedom Forward The information contained in this user s guide is subject to change without notice. This Programming and

More information

ELECTRONIC DISPLAYS INC. 135 S. CHURCH STREET ADDISON, ILL

ELECTRONIC DISPLAYS INC. 135 S. CHURCH STREET ADDISON, ILL ELECTRONIC DISPLAYS INC. 135 S. CHURCH STREET ADDISON, ILL. 60101 www.electronicdisplays.com PRODUCT PART NUMBER : ED225MPC 2L N1-VERT-1001- KYN1 DESCRIPTION: Indoor 4 digit, 2.25 inch high, red LED, 2

More information

PROGRAMMABLE MARQUEE DISPLAYS

PROGRAMMABLE MARQUEE DISPLAYS PROGRAMMABLE MARQUEE DISPLAYS INTRODUCTION: AVG Uticor Marquees can be found in numerous applications throughout all industries. In 1996, a CONTROL ENGINEERING Magazine study named the AVG Uticor brand

More information

Electronic SD1, AS 8, ASR 14, ASR 20

Electronic SD1, AS 8, ASR 14, ASR 20 Electronic SD1, AS 8, ASR 14, ASR 20 2 Electronic SD1, AS 8, ASR 14, ASR 20 Contents Page List of contents..................................................... 3 Function and characteristics.........................

More information

High Precision Dispensers. Ultimus I, II, III, IV and V

High Precision Dispensers. Ultimus I, II, III, IV and V High Precision Dispensers Ultimus I, II, III, IV and V Ultimus I, II and III Features and Benefits All-digital, multi-function display 16 memory settings 4-decimal time setting Multilingual display Operator

More information

Vorne Industries. 2000S Series Serial Input Alphanumeric Display User's Manual

Vorne Industries. 2000S Series Serial Input Alphanumeric Display User's Manual Vorne Industries 2000S Series Serial Input Alphanumeric Display User's Manual 1445 Industrial Drive Itasca, IL 60143-1849 Telephone (630) 875-3600 Telefax (630) 875-3609 2000S Series Serial Input Alphanumeric

More information

KNC Model 3719 Air Data Test Set

KNC Model 3719 Air Data Test Set KNC Model 3719 Air Data Test Set Product Description The Model 3719 Air Data Test Set by King Nutronics Corporation is a highly accurate microprocessor-driven pressure calibrator designed to provide regulated

More information

Tél. +41 (0) CH la Chaux-de-Fonds Case postale 2320

Tél. +41 (0) CH la Chaux-de-Fonds Case postale 2320 AeRO 30 This lightweight, compact, single-hose low pressure, electric blasting system utilizes dry ice pellets in it s patented aerodynamic rotor assuring high reliability and a smooth pulse-free dry ice

More information

D840/D820. Remote Display Installation Manual

D840/D820. Remote Display Installation Manual D840/D820 Remote Display Installation Manual Copyright All Rights Reserved. No part of this document may be copied, reproduced, republished, uploaded, posted, transmitted, distributed, stored in or introduced

More information

Micro Motion Model 7950 and Model 7951 Signal Converters

Micro Motion Model 7950 and Model 7951 Signal Converters Product Data Sheet PS-001316, Rev. B April 2013 Micro Motion Model 7950 and Model 7951 Signal Converters Micro Motion Model 7950 and Model 7951 signal converters are the perfect complement to Micro Motion

More information

Si 2035 Programmable Stepper Drive

Si 2035 Programmable Stepper Drive Si 23 Programmable Stepper Drive Description The Si23 is a programmable stepper drive/ indexer packaged in a rugged steel case. Integral heat sink, mounting brackets, switch covers and connectors are included

More information

COLumn-mounted systems

COLumn-mounted systems COLumn-mounted systems Dot Standalone dot peen marking stations peen columns e10 Range e10-c153 e10-c303 e10-c153 z a Dot peen Technology dot peen technology : fast marking on all materials! intégrables

More information

EV15 Laser Marking System

EV15 Laser Marking System EV15 Laser Marking System General Arrangement SYSTEM OVERVIEW The Telesis EV15 is an advanced, fiber-coupled diode pumped solid state (DPSS) laser marking system. The laser beam and Q-switched pulse characteristics

More information

1:N REDUNDANT SWITCHING UNIT REMOTE CONTROL TERMINAL

1:N REDUNDANT SWITCHING UNIT REMOTE CONTROL TERMINAL MITEQ TECHNICAL NOTE 25T051 OCTOBER 2001 REV B 1.1 GENERAL DESCRIPTION 1.1.1 PHYSICAL 1:N REDUNDANT SWITCHING UNIT REMOTE CONTROL TERMINAL SECTION 1 INTRODUCTION Figure 1-1. Front Panel, 1:N Redundant

More information

Requires QuickControl v6.22 or greater to initialize and program SilverMax servo.

Requires QuickControl v6.22 or greater to initialize and program SilverMax servo. Datasheet: QCI-DS3 Date: 2 September 217 www.quicksilvercontrols.com SilverMax 23 Frame X-Series The SilverMax is a fully integrated Hybrid Servo Motor with feedback, a Controller/Indexer, and a Digital

More information

K10 Intrinsically Safe Electro-Pneumatic Positioner Operating Manual

K10 Intrinsically Safe Electro-Pneumatic Positioner Operating Manual K0 Intrinsically Safe Electro-Pneumatic Positioner Operating Manual Pneumatic Connection Single Acting Actuator (Spring Return): For single acting actuators Outlet Port 2 is to be plugged. Outlet Port

More information

Programmable stepper motor control board (2 axis)

Programmable stepper motor control board (2 axis) Data pack B Issued March 2002 232-3692 Programmable motor control board (2 axis) Control board RS stock no. 440-098 Control software RS stock no. 440-105 General (RS stock no. 440-098) This board is designed

More information

DATAMARK DOT PEEN MARKING MACHINES. Datamark INDUSTRIAL MARKING SYSTEMS

DATAMARK DOT PEEN MARKING MACHINES. Datamark INDUSTRIAL MARKING SYSTEMS DATAMARK DOT PEEN MARKING MACHINES Datamark INDUSTRIAL MARKING SYSTEMS DATAMARK MARKING MACHINES 2 3 1 4 5 DATAMARK Dot Peen marking machines allow to create identification marks with adjustable depth

More information

QuickSilver Controls, Inc. Datasheet: QCI-DS030. SilverMax 23 Frame X-Series

QuickSilver Controls, Inc. Datasheet: QCI-DS030. SilverMax 23 Frame X-Series Datasheet: QCI-DS3 Date: 7 June 216 www.quicksilvercontrols.com SilverMax 23 Frame X-Series The SilverMax is a fully integrated Hybrid Servo Motor with feedback, a Controller/Indexer, and a Digital Driver

More information

InfoTag KE28xx Communications for 186 CPU Firmware Version 4

InfoTag KE28xx Communications for 186 CPU Firmware Version 4 InfoTag KE28xx Communications for 186 CPU Firmware Version 4 *KE28xx models include: KE2800, KE2852, KE2853, KE2856 This document applies to printer firmware versions 4.x only. Note that changes made to

More information

MDrive Linear Actuator

MDrive Linear Actuator MDrive Linear Actuator Compact, integrated all-in-one linear motion systems MDrive 14 Plus Linear Actuator, Description MDrive Plus Linear Actuator Presentation The MDrive Plus Linear Actuator is an integrated

More information

Mounting the Model 2601

Mounting the Model 2601 Control Technology Corporation Model 2601 Automation Controller Installation Guide Model 2601 Automation Controller This document is current as of the following revision levels: Controller Firmware 2.24

More information

USB VGA KVM Console Extender w/ Serial & Audio Over Cat5 UTP ft

USB VGA KVM Console Extender w/ Serial & Audio Over Cat5 UTP ft USB VGA KVM Console Extender w/ Serial & Audio Over Cat5 UTP - 1000 ft Product ID: SV565UTPUSA The SV565UTPUSA USB VGA KVM Console Extender w/ Serial & Audio Over Cat5 UTP (1000 ft) lets you control a

More information

H704-42(H)(E), H704-42/1(H)(E)

H704-42(H)(E), H704-42/1(H)(E) POWER MONITORING INSTALLATION GUIDE H704-42(H)(E), H704-42/1(H)(E) Branch Current Monitor DANGER NOTICE Installer's Specifications General: Operating Temp. Range 0 to 60 C (32 to 140 F) (

More information

DL1000 DURABILITY & LUBRICITY TEST SYSTEM

DL1000 DURABILITY & LUBRICITY TEST SYSTEM OakRiver Technology s DL1000 provides accurate, reliable measurement of the durability and lubricity of hydrophilic coatings on catheters and guidewires. Engineered with robust components and controls,

More information

PRELIMINARY. CR Series. Ceiling Rack Systems with AmbiTILT Equipment Loading

PRELIMINARY. CR Series. Ceiling Rack Systems with AmbiTILT Equipment Loading 1/6 CR Series Ceiling Rack Systems with AmbiTILT Equipment Loading General Description AtlasIED, the manufacturing leader of ceiling mounted loudspeakers introduces the new CR Series ceiling-mounted equipment

More information

EMERALD SERIES AUTOMATION CONTROLLER JANUARY 2017 EMERALD EMC INDUSTRIAL INDEXING SYSTEMS, Inc. INSTRUCTION BOOK

EMERALD SERIES AUTOMATION CONTROLLER JANUARY 2017 EMERALD EMC INDUSTRIAL INDEXING SYSTEMS, Inc. INSTRUCTION BOOK EMERALD SERIES AUTOMATION CONTROLLER JANUARY 2017 EMERALD EMC-2100 INDUSTRIAL INDEXING SYSTEMS, Inc. Revision 0 Approved By: CME INSTRUCTION BOOK Proprietary information of Industrial Indexing Systems,

More information

Z Spindle. Revision 1.2. Copyright Newing-Hall, Inc Monroe Street. Toledo, Ohio, NH Part # Last Update July 2003

Z Spindle. Revision 1.2. Copyright Newing-Hall, Inc Monroe Street. Toledo, Ohio, NH Part # Last Update July 2003 Z Spindle Revision 1.2 Copyright 1998-1999 Newing-Hall, Inc. 2019 Monroe Street Toledo, Ohio, 43624 NH Part #2511013 Last Update July 2003 This manual is subject to change without notice. Table Of Contents

More information

TM ARGREITER TECHNIK. [ Heftklammern ] [ Marking products ] Dot marking machine. Advantages. Bench mounted dot marking machine.

TM ARGREITER TECHNIK. [ Heftklammern ] [ Marking products ] Dot marking machine. Advantages. Bench mounted dot marking machine. Dot marking technology is a most flexible and time saving method of marking various components. Dot marking is also called peen marking, stylus pin marking or micro-percussion marking. This technique intends

More information

It is the installer's responsibility to follow all instructions in this manual and to follow correct electrical practice.

It is the installer's responsibility to follow all instructions in this manual and to follow correct electrical practice. MCD Modbus Module Instructions Important User Information INSTALLATION INSTRUCTIONS: MCD MODBUS MODULE Order Code: 175G9000 1. Important User Information Observe all necessary safety precautions when controlling

More information

DIMENSION/WEIGHT kpa. 0 to 20 m / 0 to 60 ft 0 to 2 bar / 0 to 29 psi. 0 to 50 m / 0 to 160 ft 0 to 5 bar / 0 to 72.5 psi

DIMENSION/WEIGHT kpa. 0 to 20 m / 0 to 60 ft 0 to 2 bar / 0 to 29 psi. 0 to 50 m / 0 to 160 ft 0 to 5 bar / 0 to 72.5 psi V161102 Liquid Level Sensor Sensor for measuring the level of liquid in a well or tank USE / PURPOSE The range of liquid level sensors use pressure to measure the liquid level in a well or tank. The sensors

More information

MDrive Linear Actuator

MDrive Linear Actuator MDrive Linear Actuator Compact, integrated all-in-one linear motion systems MDrive 23 Plus Linear Actuator, Description MDrive Plus Linear Actuator Presentation The MDrive Plus Linear Actuator is an integrated

More information

Mechanically Activated Device for Dry Run Protection in Applications with LORENTZ Solar Pump Systems

Mechanically Activated Device for Dry Run Protection in Applications with LORENTZ Solar Pump Systems Well Probe Mechanically Activated Device for Dry Run Protection in Applications with LORENTZ Solar Pump Systems The switch can be used to detect the water level within a well. When the water level in the

More information

ESM-5907 MOTORIZED INSERTION STANDARD TYPE MAGNETIC CARD READER & IC CARD READER/WRITER WITH RS-232C INTERFACE

ESM-5907 MOTORIZED INSERTION STANDARD TYPE MAGNETIC CARD READER & IC CARD READER/WRITER WITH RS-232C INTERFACE DOC. NO. ESM-5907 REV. PAGE DATE SPECIFICATION A 1 OF 19 2002.09.18 ESM-5907 MOTORIZED INSERTION STANDARD TYPE MAGNETIC CARD READER & IC CARD READER/WRITER WITH RS-232C INTERFACE KyungDuck Bldg, 518-5,

More information

A Issue A Original. Instruction Manual. nxds Serial Comms Interface

A Issue A Original. Instruction Manual. nxds Serial Comms Interface Instruction Manual A735-01-860 Issue A Original nxds Serial Comms Interface Description nxds6i nxds10i nxds15i nxds20i Item Number A735-01-983 A736-01-983 A737-01-983 A738-01-983 nxds6ic nxds10ic nxds15ic

More information

120 psi (0.827 MPa) * psi (.48 MPa)

120 psi (0.827 MPa) * psi (.48 MPa) Fuji ACE Model Load Capacity (Including End Effector) Palletizing Capacity (cycles / hour) Degree of freedom EC-101 Cylindrical 160kg (353 lbs) 800 cycles / hour 4 axis Z axis (vertical) 2300 mm (90.5")

More information

TPE 1464 Series Pressure Transducer

TPE 1464 Series Pressure Transducer TPE 1464 Series Pressure Transducer Description The KMC TPE 1464 series of pressure transducers incorporate a gauge pressure transmitter featuring low hysteresis, excellent repeatability, and longterm

More information

D730. Remote Display Installation Manual

D730. Remote Display Installation Manual D730 Remote Display Installation Manual Copyright All Rights Reserved. No part of this document may be copied, reproduced, republished, uploaded, posted, transmitted, distributed, stored in or introduced

More information

ECS ecompass Series. ECS ecompass Series. Strap down Electronic Compass. General Description. Features. Making Sense out of Motion

ECS ecompass Series. ECS ecompass Series. Strap down Electronic Compass. General Description. Features. Making Sense out of Motion ECS ecompass Series Strap down Electronic Compass General Description Features High Accuracy Heading within 0.5 or better Tilt within 0.2 or better Wide Operating Range ±42 Pitch and Roll ±80 Dip angle

More information

ASI Systems ML5740A Series

ASI Systems ML5740A Series ML5740A Series Electric Linear Valve Actuators Non-Spring Return APPLICATION The ML5740A series actuators operate standard ASI Systems valves in heating, ventilating and air conditioning (HVAC) applications.

More information

ASI Systems ML5720A Series

ASI Systems ML5720A Series ML5720A Series Electric Linear Valve Actuators Non-Spring Return APPLICATION The ML5720A series actuators operate standard ASI Systems valves in heating, ventilating and air conditioning (HVAC) applications.

More information

C-Series C142 Machine Controller Eurocard DIN Packaged Systems

C-Series C142 Machine Controller Eurocard DIN Packaged Systems C-Series C142 Machine Controller Eurocard DIN Packaged Systems FEATURES: Available as 2- or 3-axes CNC Controller Remote START/STOP/RESET Bidirectional serial communication at up to 192 baud 32K of on-board

More information

Bulletin 871D Cylinder Position Inductive Style

Bulletin 871D Cylinder Position Inductive Style Bulletin 871D Cylinder Position Inductive Style Description Bulletin 871D cylinder position inductive proximity sensors are self-contained solid state devices. These devices are designed for sensing metal

More information

L5351 DeviceNet Communications Interface

L5351 DeviceNet Communications Interface L5351 DeviceNet Communications Interface Technical Manual HG353798 Issue 2 Copyright SSD Drives, Inc 2005 All rights strictly reserved. No part of this document may be stored in a retrieval system, or

More information

IT 1910i. Industrial 2D-code hand-held scanner TECHNICAL DESCRIPTION. make technical changes EN /06. We reserve the right to

IT 1910i. Industrial 2D-code hand-held scanner TECHNICAL DESCRIPTION. make technical changes EN /06. We reserve the right to IT 1910i Industrial 2D-code hand-held scanner EN 50123791 2013/06 We reserve the right to make technical changes TECHNICAL DESCRIPTION 2013 Leuze electronic GmbH + Co. KG In der Braike 1 D-73277 Owen /

More information

Andover Continuum. Power Supplies with or without UPS

Andover Continuum. Power Supplies with or without UPS Andover Continuum Power Supplies with or without UPS The Andover Continuum TM PS 120/240 AC 50-U, PS 120/240 AC 65-U and PS120/240 AC 85-U power supply modules are designed to provide 24 VDC power for

More information

1551 S. Harris Court,. Anaheim, CA Phone: Fax:

1551 S. Harris Court,. Anaheim, CA Phone: Fax: 1551 S. Harris Court,. Anaheim, CA 92806 Phone: 714.978.1551... Fax: 714.978.0431 Model 4KE / 4KEH Series: Semi-Automatic, Motorized Y/Z Axes, Wedge-Wedge, Ball- Wedge Triple-Convertible Wire Bonders Last

More information

PK2200 Series. Features. C-Programmable Controller. Specifications Board Size Enclosure Size Operating Temp.

PK2200 Series. Features. C-Programmable Controller. Specifications Board Size Enclosure Size Operating Temp. C-Programmable Controller P00 Series The P00 Series of C-programmable controllers is based on the Zilog Z80 microprocessor. The P00 includes digital, serial, and high-current switching interfaces. The

More information

MTII4200 Level Transmitter Installation, Operation & Maintenance Instructions

MTII4200 Level Transmitter Installation, Operation & Maintenance Instructions Specialists in Liquid Level Indication MTII4200 Level Transmitter Installation, Operation & Maintenance Instructions Section: M500 Bulletin: M500.31 Date: 05-17-16 Supersedes: 09-30-11 1. INTRODUCTION

More information

PosiStep - Single Axis Packaged Intelligent Microstepping Drive

PosiStep - Single Axis Packaged Intelligent Microstepping Drive Precision Motion Control Brushless Motors Stepper Motors AC Synchronous DC Servo Motors Gearheads Encoders Systems Fieldbus Gateways CAM Control Mechanical Integration PosiStep - Single Axis Packaged Intelligent

More information

Vorne Industries. Model 77/232 Serial Input Numeric 3" Display User's Manual

Vorne Industries. Model 77/232 Serial Input Numeric 3 Display User's Manual Vorne Industries Model 77/232 Serial Input Numeric 3" Display User's Manual 1445 Industrial Drive Itasca, IL 60143-1849 (630) 875-3600 Telefax (630) 875-3609 Page 2 Model 77/232 Serial Input Numeric 3"

More information

Kramer Electronics, Ltd. USER MANUAL. Model: VS-1616A. 16x16 Balanced Stereo Audio Matrix Switcher

Kramer Electronics, Ltd. USER MANUAL. Model: VS-1616A. 16x16 Balanced Stereo Audio Matrix Switcher Kramer Electronics, Ltd. USER MANUAL Model: VS-1616A 16x16 Balanced Stereo Audio Matrix Switcher Contents Contents 1 Introduction 1 2 Getting Started 1 3 Overview 2 4 Your Balanced Stereo Audio Matrix

More information

ADDMASTER. Addmaster Corporation. IJ-3080 Journal/Validation Printer. Specification. IJ-3080 Specification

ADDMASTER. Addmaster Corporation. IJ-3080 Journal/Validation Printer. Specification. IJ-3080 Specification IJ-3080 Journal/Validation Printer Specification Provides the electrical, mechanical, and interface specifications of the IJ-3080 Journal/Validation Printer. Cover Models: IJ-3080 The Addmaster Model IJ-3080

More information

UPGRADE PROGRAM. V70 Series Pumps vs V81T Series Pumps

UPGRADE PROGRAM. V70 Series Pumps vs V81T Series Pumps VARIAN vacuum technologies UPGRADE PROGRAM V70 Series Pumps vs V81T Series Pumps Technical Memo Technical Memo - 1 - V70 series vs V81-T INDEX Outline drawings ISO63 3 Outline drawings CF2-¾ 4 Outline

More information

REV6 Multi Sector MIFARE Reader/Writer Data Sheet

REV6 Multi Sector MIFARE Reader/Writer Data Sheet 716-52 REV6 Multi Sector MIFARE Reader/Writer Data Sheet Overview The 716-52 REV6 multi sector MIFARE Reader/Writer is an intelligent 13.56MHz contactless reader writer designed to operate with the Mifare

More information

Mini Probe. user manual. DM Models

Mini Probe. user manual. DM Models Mini Probe user manual DM Models 1.0: Index Section Title Page 1.0 Index...............................2 2.0 Safety Summary......................3 3.0 Introduction..........................4 4.0 Components

More information

Instruction Manual CTC-1

Instruction Manual CTC-1 Troubleshooting & Specs CTC-1 Amps / Volts requirements Min / Max operating temperature Min / Max operating Humidity Temperature Measurement range Temperature Accuracy CO2 sensor type CO2 Measurement range

More information

Hardinge 5C Gear-Driven Indexer

Hardinge 5C Gear-Driven Indexer Indexer/Rotary Hardinge 5C Gear-Driven Indexer Quotation To: Budgetary Quote Prices Valid for 30 Days Your Hardinge Representative: Al Comstock 607.378.4044 al.comstock@hardinge.com Hardinge Inc. One Hardinge

More information