PROFIBUS Junctions, Connectors, Accessories

Size: px
Start display at page:

Download "PROFIBUS Junctions, Connectors, Accessories"

Transcription

1 Data heet PROFIU Junctions, Connectors, ccessories PROFIU P Junctions Connectors ccessories PROFIU DP Junctions Connectors ccessories PROFIU DP/P ccessories P R O F I PROCE FIELD U U

2 PROFIU Junctions, Connectors, ccessories PROFIU P The PROFIU P T-Connectors are available as tandard and Ex(Haz.) version. They are used for coupling 1 up to 4 transmitters to the P trunk via spurs. The spurs can optionally be connected by an M1 connection or directly via the EMC cable gland. Non-interrupted U operation when exchanging or extending a P transmitter Easy to use Low installation costs External grounding cable Pressure-compensation element EMC cable gland Tension spring connection luminium (standard) housing Non-Ex design (integrated bus termination, switchable) Ex(Haz.) design acc. to TEX (external bus termination with NPZ100-EX) NPJ10-NO, NPJ130-NO, NPJ40-NO, NPJ460-NO PROFIU P Junctions - Non-Ex version Recommendation of mounting hield is connected to the enclosure via the EMC cable glands. Thread the cable gland onto the seal, on the unprepared fieldbus cable trip fieldbus cable here Use ferrules! Fieldbus cable hielding Draw back the shielding braid over the sheath of the fieldbus cable 6 Technical data Temperature range Operating temperature C Type of protection IP 66 Material of housing high-quality aluminium alloy (L-i 1) urface stove-enamelled RL 7001 PROFIU P connection tension spring mm Cable bushing EMC cable gland M16 Clamping area mm Measuring instrument connector M1 x 1, 4pin contacts brass, surface CuZnu Installation advice Torques M16 cable gland on housing Coupling ring M16 cable gland Housing lid External earthing cable 6.5 Nm 4.5 Nm Nm Nm

3 PROFIU Junctions, Connectors, ccessories PROFIU P NPJ10-NO (JPN10) PROFIU P Junction Non-Ex version, with bus termination The Transmitter (spur, 1-way) are connected using M1 connection. 58 off on R1 C1 36,5 ocket M1 / P code Wire bridge us Terminator 100R off on R1 C1 1uF 50Vdc us terminator: 64 off on Enclosure P- (3) hielding(4) P+ (1) () NPJ130-NO (JPN130) PROFIU P Junction Non-Ex version, with bus termination The Transmitter (spur, 1-way) are connected using cable bushing off on off 64 on R1 R1 C1 15 C1 36,5 36,5 36,5 us terminator: off off on us terminator: on Wire bridge Enclosure Enclosure Wire bridge us Terminator 100R NPJ40-NO (JPN40) PROFIU P Junction Non-Ex version, with bus termination The Transmitter (spurs, 4-way) are connected using M1 connection. ocket M1 / P code NPJ460-NO (JPN460) PROFIU P Junction Non-Ex version, with bus termination The Transmitter (spurs, 4-way) are connected using cable bushing. Wire bridge off on R1 C1 1uF 50Vdc P- (3) hielding(4) P+ (1) () us Terminator pluggable 100R 1uF 63V P- (3) hielding(4) P+ (1) () us Terminator pluggable 100R 1uF 63V off on R1 C1 15 ll drawings not scaled! ll units in millimeter! us terminator: off on Enclosure P- (3) hielding(4) P+ (1) () 3

4 PROFIU Junctions, Connectors, ccessories PROFIU P NPJ10-EX, NPJ130-EX, NPJ40-EX, NPJ460-EX PROFIU P Junctions Ex area EEx (ia) TEX Recommendation of mounting: hield is connected to the enclosure via the EMC cable glands. Thread the cable gland onto the seal, on the unprepared fieldbus cable trip fieldbus cable here Use ferrules! Fieldbus cable hielding Draw back the shielding braid over the sheath of the fieldbus cable 6 Technical data Temperature range Operating temperature C Type of protection IP 66 Material of housing high-quality aluminium alloy (L-i 1) urface stove-enamelled RL 5015 PROFIU P connection tension spring mm Cable bushing EMC cable gland M16 Clamping area mm Measuring instrument connector M1 x 1, 4pin contacts brass, surface CuZnu TEX Certification II G EEx ia IIC T6 Installation advice Torques M16 cable gland on housing Coupling ring M16 cable gland Housing lid dapter / spur cable External earthing cable 6.5 Nm 4.5 Nm Nm hand-tight Nm 4

5 PROFIU Junctions, Connectors, ccessories PROFIU P NPJ10-EX (JPE10-Ex) PROFIU P Junction Ex area EEx (ia) TEX, without bus termination The Transmitter (spur, 1-way) are connected using M1 connection. 36, ocket M1 / P code us terminator: With external NPZ100-EX only Wire bridge Enclosure P- (3) hielding(4) P+ (1) () NPJ130-EX (JPE130-Ex) PROFIU P Junction Ex area EEx (ia) TEX, without bus termination The Transmitter (spur, 1-way) are connected using cable bushing NPJ40-EX (JPE40-Ex) NPJ460-EX (JPE460-Ex) 15 ll drawings not scaled! ll units in millimeter! 36,5 36,5 36,5 us terminator: With external NPZ100-EX only PROFIU P Junction Ex area EEx (ia) TEX, without bus termination The Transmitter (spurs, 4-way) are connected using M1 connection. us terminator: With external NPZ100-EX only us terminator: With external NPZ100-EX only ocket M1 / P code Wire bridge Enclosure Enclosure Wire bridge P- (3) hielding(4) P+ (1) () PROFIU P Junction Ex area EEx (ia) TEX, without bus termination The Transmitter (spurs, 4-way) are connected using cable bushing. Wire bridge Enclosure P- (3) hielding(4) P+ (1) () P- (3) hielding(4) P+ (1) () 5

6 6

7 PROFIU Junctions, Connectors, ccessories PROFIU P NPZ100-EX (PE100-Ex) PROFIU P us Terminator Ex area EEx (ia) TEX Cable brown Cable white Technical data Temperature range/operating temperature ºC Type of protection IP 66 Material of housing high-quality aluminium alloy (L-i 1) urface black powder coated Connecting cable x 0.14 mm Cable bushing us adapter M16 TEX Certification II G EEx ia IIC T6, II G EEx m II T6 Installation advice Torques M16 adapter on the housing External earthing cable (if necessary) 6.0 Nm Nm ,5 II G EEx ia IIC T6 EEx m II T6 Ui 17,5 V V Ii 380 m Ta : C KEM 01 TEX 1058 X ,5 ll drawings not scaled! ll units in millimeter! 7

8 PROFIU Junctions, Connectors, ccessories PROFIU P NPE100-NE (EPG100) PROFIU P Plug - M1, metal case, for Ex (Haz.) and Non-Ex area Technical data Poles 4 Poles, P code Type of connection screwed Cross-sectional area of connection 0.75 mm Connecting thread M1 Contact surface CuZnu Housing protection to DIN IEC 59 IP 67 with cable Ø mm Material of housing Cu Zn surface nickel Inflammability to UL-94 V- Operating temperature -5 C C Rated current per contact 3 Nominal voltage to VDE standard 0110/IO group C 15 V ~ 150 V = Tracking resistance KC 600 Volume resistivity to IEC51 part 8 MΩ Insulation resistance to IEC 51 part 1 10 Ω Installation advice crew terminals Torques 0.4 Nm Coupling ring PG cable gland 4.0 Nm Knurled screw hand-tightl Dimensions Recommendation of mounting ca. 59 M1 x 1,5 Ø ll drawings not scaled! ll units in millimeter! 4 Use wire-end ferrules! Put isolating tube over the shield! Frontview of plug and socket connector -pole fieldbuscable with shield (diameter about 8 mm ). Mounting by customer. Pressure screw Terminal clamp Washer hieldring with washer Wreath M16 x 0,75 Coupling sleeve M18 / M16 x 0.75 with mounted sleeve Wreath M18 Pins with screwed connection Wreath M18 outside Fixed screw Revolving screw Wreath M1 x 1 Male wire-colour red not used green bus P+ Pshield referenz equense of mounting: 1. Put the fieldbuscable through pressure screw, terminal clamp, washer, shieldring with washer.. Caution: Only for EMV! trip the fieldbuscable here, lay the shield over the shieldring. Cut the rest of the shield. hield can be connected, as drawing, with pin of the plug and socket connector. Prepare the cable as shown in the drawing. 3. Put prepared ends of the cable through the coupling sleeve. It s possible to use an isolating tube for the cable ends. Put shieldring with washer and shield into the coupling sleeve. Put washer, terminal clamp and pressure screw together. Then fix the pressure screw. 4. Fix the cable ends at the pins,, of he plug and socket connector. crew coupling sleeve and part with pins,, together. crew Positionmark! View to connecting piece PROTECTION REMRK TO DIN 34 MUT E OERVED 8

9 PROFIU Junctions, Connectors, ccessories PROFIU P NPE300-NE (EPG300) PROFIU P ocket M1, metal case, for Ex (Haz.) and Non-Ex area Technical data Poles 4 Poles, P code Type of connection screwed Cross-sectional area of connection 0.75 mm Connecting thread M1 Contact surface CuZnu Housing protection to DIN IEC 59 IP 67 with cable Ø mm Material of housing Cu Zn surface nickel Inflammability to UL-94 V- Operating temperature -5 C C Rated current per contact 3 Nominal voltage to VDE standard 0110/IO group C 15 V ~ 150 V = Tracking resistance KC 600 Volume resistivity to IEC51 part 8 MΩ Insulation resistance to IEC 51 part 1 10 Ω Installation advice Torques crew terminals 0.4 Nm Coupling ring PG cable gland 4.0 Nm Knurled screw hand-tight Dimensions Recommendation of mounting -pole fieldbuscable with shield (diameter about 8 mm ). Mounted by customer. Pressure screw Terminal clamp Washer Recommendation of mounting: 1. Put the fieldbuscable through pressure screw, terminal clamp, washer, shieldring with washer.. Caution: Only for EMV! trip the fieldbuscable here and lay the shield over the shieldring. Cut the rest of the shield. hield can be connected, as drawing, with socket. Prepare the cable as shown in the drawing. ~ 54,5 Ø M1 x ll drawings not scaled! ll units in millimeter! 4 Put wire-end ferrule above the wires Put isolating tube over the shield! Frontview of the socket Positionmark hieldring with washer Wreath M16 x 0,75 Coupling sleeve M18 / M16 x 0.75 with mounted sleeve Wreath M18 socket for screwed connection Wreath inside M18 Fixed screwl Revolving screw Wreath inside M1 x 1 Male wire-colour red not used green bus P+ Pshield referenz 3. Put prepared wires and perhaps isolated shield through the coupling sleeve. Put shieldring with washer and shield into the coupling shield. Put washer, terminal clamp and pressure screw together. Then fix the pressure screw. 4. Fix the cable ends at the socket pins,,. crew the coupling sleeve and the part with the sockets together. View to connecting piece crew PROTECTION REMRK TO DIN 34 MUT E OERVED Positionmark 9

10 PROFIU Junctions, Connectors, ccessories PROFIU DP The PROFIU DP T-Connectors are available as luminium and tainless teel version. They are used for coupling one transmitter to the DP trunk via spurs. The spurs can optionally be connected by an M1 connection or directly via the EMC cable gland (for luminium version only). Non-interrupted U operation when exchanging a DP transmitter, as well as the last DP Transmitter by an active bus termination. Easy to use Low installation costs External grounding cable Pressure-compensation element EMC cable gland (for luminium version only) Tension spring connection tandard design (integrated bus termination) Version as active bus termination (integrated Power supply) luminum (tandard) and tainless teel version NDJ10-NO, NDJ1-NO, NDJ130-NO, NDJ13-NO PROFIU DP Junctions luminium housing Recommendation of mounting hield is connected to the enclosure via the EMC cable glands. Thread the cable gland onto the seal, on the unprepared fieldbus cable trip fieldbus cable here Fieldbus cable hielding Draw back the shielding braid over the sheath of the fieldbus cable 6 Use ferrules! Technical data Temperature range Operating temperature C (NDJ10-NO, NDJ130-NO) C (Term 4 V: NDJ1-NO, NDJ13-NO) Type of protection IP 66 Material of housing high-quality aluminium alloy (L-i 1) urface stove-enamelled RL 7001 PROFIU DP connection tension spring mm Cable bushing EMC cable gland M16 Clamping area mm Transmitter connector M1 x 1, 5pin, DP code contacts brass, surface CuZnu upply voltage Term 4 V 4 V DC +/-10% Charing rate at supply unit 4 V DC Ie = 10 m +15% at bus utilisation until 3 participants pur lines (L ) until 1500 kit/s! Installation advice Torques M16 cable gland on housing Coupling ring M16 cable gland dapter spur cable Housing cover External earthing connection per spur max. 0.5 m, max. Over-all spur lines 6.60 m per DP segment 6.5 Nm 4.5 Nm hand tight Nm Nm 10

11 PROFIU Junctions, Connectors, ccessories PROFIU DP NDJ10-NO PROFIU DP Junction luminium housing, without bus termination The Transmitter (spur, 1-way) are connected using M1 connection. 36, ocket M1 / DP code (1) -> () -> RxD/TxD-N (3) -> n.c (4) -> RxD/TxD-P (5) -> hield / chirm NDJ1-NO PROFIU DP Junction luminium housing, with active bus termination (4 V DC) The Transmitter (spur, 1-way) are connected using M1 connection. 36,5 ocket M1 / DP code (1) -> () -> RxD/TxD-N (3) -> n.c (4) -> RxD/TxD-P (5) -> hield / chirm NDJ130-NO PROFIU DP Junction luminium housing, without bus termination The Transmitter (spur, 1-way) are connected using cable bushing. 36, NDJ13-NO PROFIU DP Junction luminium housing, with active bus termination (4 V DC) The Transmitter (spur, 1-way) are connected using cable bushing. 36, ll drawings not scaled! ll units in millimeter! 11

12 PROFIU Junctions, Connectors, ccessories PROFIU DP NDJ10-NO, NDJ1-NO PROFIU DP Junctions tainless steel housing Recommendation of mounting Pressurescrew, rubber washer must be put on the unprepared fieldbus cable tripped fieldbus cable hield will be connected with terminal to the housing Use ferrules! Technical data Temperature range Operating temperature C (NDJ10-NO) C (Term 4 V: NDJ1-NO) Type of protection IP 66 Material of housing stainless steel urface polished PROFIU DP connection tension spring mm Cable bushing plastic screwed cable gland M16 Clamping area mm Transmitter connector M1 x 1, 5pin, DP code upply voltage Term 4 V 4 V DC +/-10% Charing rate at supply unit 4 V DC Ie = 10 m +15% at bus utilisation until 3 participants pur lines (L ) until 1500 kit/s! per spur max. 0.5 m, max. Over-all spur lines 6.60 m per DP segment Installation advice Torques M16 plastic screw cable gland on housing Coupling ring M16 cable gland dapter spur cable Housing cover External earthing connection 3.75 Nm.5 Nm hand tight Nm Nm 1

13 PROFIU Junctions, Connectors, ccessories PROFIU DP NDJ10-NO PROFIU DP Junction tainless steel housing, without bus termination The Transmitter (spur, 1-way) are connected using M1 connection. ocket M1 / DP code (1) -> () -> RxD/TxD-N (3) -> n.c (4) -> RxD/TxD-P (5) -> hield / chirm NDJ1-NO PROFIU DP Junction tainless steel housing, with active bus termination (4 V DC) The Transmitter (spur, 1-way) are connected using M1 connection. ocket M1 / DP code (1) -> () -> RxD/TxD-N (3) -> n.c (4) -> RxD/TxD-P (5) -> hield / chirm ll drawings not scaled! ll units in millimeter! 13

14 PROFIU Junctions, Connectors, ccessories PROFIU DP NDE100-NE PROFIU DP Plug M1, metal case, for Ex (Haz.) and Non-Ex area Technical data Poles 5 Poles, DP code Type of connection screwed Cross-sectional area of connection 0.75 mm Connecting thread M1 Contact surface CuZnu Housing protection to DIN IEC 59 IP 67 with cable Ø mm Material of housing Cu Zn surface nickel Inflammability to UL-94 V- Operating temperature -5 C C Rated current per contact 3 Nominal voltage to VDE standard 0110/IO group C 15 V ~ 150 V = Tracking resistance KC 600 Volume resistivity to IEC51 part 8 MΩ Insulation resistance to IEC 51 part 1 10 Ω Installation advice crew terminals Coupling ring PG cable gland Knurled screw Torques 0.4 Nm 4.0 Nm hand-tight Dimensions ca. 59,5 Ø 4 1 M1 x Frontview of plug and socket connector Male wire-colour not used green not used red bus RxD/TxD-N RxD/TxD-P shield referenz ll drawings not scaled! ll units in millimeter! PROTECTION REMRK TO DIN 34 MUT E OERVED 14

15 PROFIU Junctions, Connectors, ccessories PROFIU DP PROFIU DP Connectors NDE10-NO NDE0-NO NDE30-NO pplication PROFIU DP Connector PROFIU DP Connector PROFIU DP Connector Internet Industrial lt enabled Information Level Yes Yes Yes Connector 9-pos. D-U male connector 9-pos. D-U male connector 9-pos. D-U male connector Programming connector pos. D-U female connector Terminal resistance -- 0 Ω / 390 Ω, resistor can be enabled externally 0 Ω / 390 Ω, resistor can be enabled externally Cable feed selectable right or left, 35 selectable right or left, 35 left, 35 Terminal blocks crew-cage crew-cage crew-cage Conductor crosssection solid: mm, flexible: mm, WG: solid: mm, flexible: mm, WG: solid: mm, flexible: mm, WG: Cable diameter max. / min.: 8 mm (± 0.4 mm) max. / min.: 8 mm (± 0.4 mm) max. / min.: 8 mm (± 0.4 mm) us cable The connector is specified for cable type according to EN (see data sheet 10/ EN) Temperature range C C C Degree of protection IP 40 IP 40 IP 40 Housing material, metal-plated, metal-plated, metal-plated Connector cycles > 00 > 00 > 00 Explosion protection FICO approval pproval CE acc. LVD CE (acc. LVD), UL, C-UL CE (acc. LVD), UL, C-UL (UL, C-UL in preparation) Protocol R 485 R 485 R 485 Max. aud Rate 1 Mbit/s 1 Mbit/s 1 Mbit/s Max. voltage 60 V C/DC 60 V C/DC 60 V C/DC Max. current Function block diagram (NDE0-NO) Dimensional diagram Construction (NDE30-NO) * ) NDE30-NO ll units in millimeter! 15

16 PROFIU Junctions, Connectors, ccessories PROFIU DP/P NDZ411-NE (PG411) Protecting Cap for all plugs M1, plastic NDZ413-NE (PG413) Protecting Cap for all sockets M1, plastic 16

17 PROFIU Junctions, Connectors, ccessories PROFIU P Ordering information PROFIU P Junctions Catalog No. EUR Deliv. time NPJ10-NO (JPN10) (856406) ,40 * wks. P T(one-way) junction, x cable bushing and 1 x socket M1 incl. switchable bus termination NPJ130-NO (JPN130) (856409) ,40 * wks. P T(one-way) junction, 3 x cable bushing incl. switchable bus termination NPJ40-NO (JPN40) (856408) ,00 * wks. P four-way junction, x cable bushing and 4 x socket M1 incl. switchable bus termination NPJ460-NO (JPN460) (856411) ,00 * wks. P four-way junction, 6 x cable bushing incl. switchable bus termination NPJ10-EX (JPE10-Ex) (856415) ,40 * wks. P T(one-way) junction, x cable bushing and 1 x socket M1 for the Ex area NPJ130-EX (JPE130-Ex) (856418) ,40 * wks. P T(one-way) junction, 3 x cable bushing for the Ex area NPJ40-EX (JPE40-Ex) (856417) ,00 * wks. P four-way junction, x cable bushing and 4 x socket M1 for the Ex area NPJ460-EX (JPE460-Ex) (85640) ,00 * wks. P four-way junction, 6 x cable bushing for the Ex area NPZ100-EX (PE100-Ex) (8606) ,70 * wks. P bus termination for the Ex area, for junction modules NPJ 0-EX PROFIU P Connectors NPE100-NE (EPG100) (945564) ,50 * wks. P plug for cable, metal case, M1, for Ex and Non-Ex area NPE300-NE (EPG300) (846) ,50 * wks. P socket for cable, metal case, M1, for Ex and Non-Ex area 17

18 PROFIU Junctions, Connectors, ccessories PROFIU DP Ordering information PROFIU DP Junctions Catalog No. EUR Deliv. time NDJ10-NO (856435) ,00 * 3 wks. DP T(one-way) junction, x cable bushing and 1 x socket M1 without bus termination, aluminum housing NDJ1-NO (856433) ,00 * 3 wks. DP T(one-way) junction, x cable bushing and 1 x socket M1 incl. active fix bus termination (4 V DC supply), aluminum housing NDJ130-NO (856434) ,90 * 3 wks. DP T(one-way) junction, 3 x cable bushing without bus termination, aluminum housing NDJ13-NO (85649) ,00 * 3 wks. DP T(one-way) junction, 3 x cable bushing incl. active fix bus termination (4 V DC supply), aluminum housing NDJ10-NO (87147) ,00 * 5 wks. DP T(one-way) junction x cable bushing (plastic) and 1 x socket M1 (tainless steel) without bus termination, stainless steel housing NDJ1-NO (87145) ,00 * 5 wks. DP T(one-way) junction x cable bushing (plastic) and 1 x socket M1 (tainless steel) incl. active fix bus termination (4 V DC supply), stainless steel housing PROFIU DP connectors NDE10-NO (PCO 010) (744597) ,80 * wks. DP plug, 9-pos. U-D, IP 40, max. 1 Md, 35 cable outlet without bus termination NDE0-NO (PCO 011) (7083) ,80 * wks. DP plug, 9-pos. U-D, IP 40, max. 1 Md, 35 cable outlet incl. switchable bus termination NDE30-NO (PCO 01) (70845) ,10 * wks. DP plug, 9-pos. U-D, IP 40, max. 1 Md, 35 cable outlet incl. switchable bus termination, programming connection U-D 900-P910 see list 17.5 DP plug for EEx i (blue!). For operating the intrinsic safety PROFIU DP max. 1.5 Md, connectable terminating resistor NDE100-NE (178479) ,50 * 3 wks. DP plug for cable, metal case, M1, for Ex and Non-Ex area PROFIU general accessories Catalog No. EUR Deliv. time NDZ411-NE (PG411) (17815) Price and Catalog No. per cap ,5 * wks. Packing unit 30 pcs., Order quantity: 30, 60, 90,...pcs. protecting cap for all plugs M1, plastic NDZ413-NE (PG413) (945605) Price and Catalog No. per cap ,46 * wks. Packing unit 30 pcs., Order quantity: 30, 60, 90,...pcs. protecting cap for all sockets M1, plastic 18

19 has ales & Customer upport expertise in over 100 countries worldwide. The Company s policy is one of continuous product improvement and the right is reserved to modify the information contained herein without notice. Printed in the Fed. Rep. of Germany (01.05) 005 Rev. utomation Products GmbH orsigstr lzenau Germany Tel: Fax: CCC-support.deapr@de.abb.com

FICHA TÉCNICA DE PRODUTO

FICHA TÉCNICA DE PRODUTO FICH TÉCNIC DE PRODUTO PRODUCT DTHEET HMI utomação e Instrumentação, Lda. Rua dos 5 Caminhos, nº 570 4780-382 anto Tirso PORTUGL Web: www.hmi.pt Tel. +351 252 850 501 Fax. +351 300 013 487 Email: hmi@hmi.pt

More information

5 Fieldbus Technology

5 Fieldbus Technology 5 Fieldbus Technology Ex e / Ex i 10922E00 The s Ex e/ex i connect intrinsically safe Foundation Fieldbus H1 or Profibus PA field devices to a non-intrinsically safe / Ex e trunk. Up to four intrinsically

More information

Han-Brid. Contents Han-Brid Features Han-Brid Data interfaces Han-Brid Overview Han-Brid Cu

Han-Brid. Contents Han-Brid Features Han-Brid Data interfaces Han-Brid Overview Han-Brid Cu Contents Page Features... 19.02 Data interfaces... 19.03 Overview... 19.04 Cu... 19.06 F.O.... 19.08 Quintax 3 A... 19.10 RJ45 C... 19.12 USB / FireWire... 19.14 Han 4 A SC... 19.16 Hoods/Housings... 19.18

More information

FieldIT Multi Barrier NMB204/NMB204-EX (MB 204/MB 204-Ex)

FieldIT Multi Barrier NMB204/NMB204-EX (MB 204/MB 204-Ex) Data Sheet FieldIT Multi Barrier NMB204/NMB204-EX (MB 204/MB 204-Ex) Intrinsically safe power supply of up to 31 stations on the bus cascadable multi barrier Intrinsically safe connection of up to 4 field

More information

PHOENIX CONTACT - 01/2008

PHOENIX CONTACT - 01/2008 Ex Basic Terminal Blocks for Intrinsically Safe Signals With Knife Disconnection and Test Connections INTERFACE Data Sheet 102957_00_en PHOENIX CONTACT - 01/2008 1 Description PI-EX-TB and PI-EX-TB/T Ex

More information

Threaded resistance thermometer Miniature design Model TR10-D

Threaded resistance thermometer Miniature design Model TR10-D Temperature Threaded resistance thermometer Miniature design Model TR10-D WIKA data sheet TE 60.04 for further approvals see page 2 Applications Machine building, plant and vessel construction Propulsion

More information

PROCESS AUTOMATION YOUR PARTNER FOR INDUSTRY-SPECIFIC INSTALLATION SOLUTIONS FIELD JUNCTION BOX

PROCESS AUTOMATION YOUR PARTNER FOR INDUSTRY-SPECIFIC INSTALLATION SOLUTIONS FIELD JUNCTION BOX PROCESS AUTOMATION YOUR PARTNER FOR INDUSTRY-SPECIFIC INSTALLATION SOLUTIONS FIELD JUNCTION BOX OUR COMPONENTS... CONFIGURABLE TO YOUR NEEDS No application is like the others; every application always

More information

Sensor Actuator Interface. Catalogue

Sensor Actuator Interface. Catalogue C T L O G U E 8 2011 2012 ensor ctuator Interface Catalogue CTLOGUE 8 ensor ctuator Interface Contents ensor ctuator Interface Introduction ensor and actuator cables Fieldbus, data cables and accessories

More information

Threaded thermocouple Miniature design Model TC10-D

Threaded thermocouple Miniature design Model TC10-D Temperature Threaded thermocouple Miniature design Model TC10-D WIKA data sheet TE 65.04 for further approvals see page 2 Applications Machine building, plant and vessel construction Propulsion technology

More information

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection NCN-FK-N-V-V 002 Model Number NCN-FK-N-V-V Features Direct mounting on standard actuators Compact and stable housing with terminal compartment connection Fixed setting EC-Type Examination Certificate TÜV99

More information

Industrial Ethernet Panel-Mount Adaptors for PROFINET or EtherNet/IP Applications

Industrial Ethernet Panel-Mount Adaptors for PROFINET or EtherNet/IP Applications Industrial Ethernet Panel-Mount Adaptors for PROFINET or EtherNet/IP Applications Type 0981 ENC 100 RJ45/M12 adaptor, female receptacle connector M12, D coding, chassis side thread PG 9, RJ45 female connector,

More information

Inductive sensor NI3-EG08K-Y1-H1341

Inductive sensor NI3-EG08K-Y1-H1341 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M8 x 1 Stainless steel, 1.4427 SO DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR)

More information

PHOENIX CONTACT Pin. SUBCON-PLUS M ARCNET, MULTI/MININET (B&R), SYSTEM 2003 (B&R), P-NET SUCONET K1, K2 (EATON/Moeller),

PHOENIX CONTACT Pin. SUBCON-PLUS M ARCNET, MULTI/MININET (B&R), SYSTEM 2003 (B&R), P-NET SUCONET K1, K2 (EATON/Moeller), Fast connector with screw terminal block connection for fieldbus systems Data sheet 00287_en_02 PHOENIX CONTACT 207-04-2 Description The SUBCON-PLUS/... D-SUB series is specifically designed for use in

More information

Technical Data. General specifications. Rated operating distance s n 3 mm

Technical Data. General specifications. Rated operating distance s n 3 mm 0102 Model Number Features Direct mounting on standard actuators Compact and stable housing with terminal compartment connection ATEX & IECEX certifications Usable up to SIL 2 acc. to IEC 61508 Weatherproof

More information

ENCODER. Profibus Multiturn. Series , Key-Features:

ENCODER. Profibus Multiturn. Series , Key-Features: ENCODER Profibus Multiturn Series 8.5868, 8.5888 Key-Features: Content: Order Code Technical Data Profibus Interface Connection Technical Drawing......3...4...4...5 - Solid shaft: maximum diameter 0 mm

More information

PowerDRIVE-Box GEL 6505 Interface for controlling up to 5 positioning drives

PowerDRIVE-Box GEL 6505 Interface for controlling up to 5 positioning drives PowerDRIVE-Box GEL 6505 Interface for controlling up to 5 positioning drives Technical information Version 208-05 GEL 6505A: Box for top hat rail mounting, IP 20 variant General The PowerDRIVE-Box GEL

More information

Emergency Luminaire for Fluorescent Lamps Series EXLUX 6009

Emergency Luminaire for Fluorescent Lamps Series EXLUX 6009 > As wall, ceiling and pendant light fitting or pole mounted light fitting > Version with 2 lamps: 18 W and 36 W > Central locking > All-pole disconnection via N/C switch when opening light fitting or

More information

Ø 11,4 21,5. M9 x 0,5 Ø 12 Ø 11,4. M9 x 0,5 Ø 12. M9 x 0,5

Ø 11,4 21,5. M9 x 0,5 Ø 12 Ø 11,4. M9 x 0,5 Ø 12. M9 x 0,5 Subminiature 7 series Screw termination M9 8 contacts Degree of protection IP7 Solder termination Moulded versions Diameter, mm Male angled connector 8,, Ø,, Contacts Cable outlet Ordering-No. 99 00 70

More information

M12 connector D-coding M12 connector X-coding RJ45 IP20 connector PushPull RJ45 IP65 / IP67 connector

M12 connector D-coding M12 connector X-coding RJ45 IP20 connector PushPull RJ45 IP65 / IP67 connector M12 connectors Directory Chapter Page General information....02 M12 connector D-coding....06 M12 connector X-coding....20 RJ45 IP20 connector....27 PushPull RJ45 IP65 / IP67 connector....46 Han 3 A RJ45

More information

D-Sub SEaled subminiature D connectors, 2.54 mm pitch

D-Sub SEaled subminiature D connectors, 2.54 mm pitch SE D-Sub SEaled subminiature D connectors, 2.54 mm pitch Page Technical characteristics.......................................... 02 IP 67 versions with turned solder cups......... 04 IP 67 versions with

More information

FLEX Ex Spring Clamp Terminal Base

FLEX Ex Spring Clamp Terminal Base Installation Instructions FLEX Ex Spring Clamp Terminal Base (Cat. No. 1797-TB3S) 1 10 11 4 Only remove this cover plug if connecting another terminal base unit. 3 5 6 12 2 7 8 9 41253 Component Identification

More information

DMP 333 DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

DMP 333 DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial DMP Industrial Pressure Transmitter For High Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO Industrial Pressure Transmitter DMP Nominal pressure

More information

Inductive sensor BI1.5-EG08-Y1-H1341

Inductive sensor BI1.5-EG08-Y1-H1341 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

VARIOSUB D-SUB 25 Contact Inserts, Sleeve Housings

VARIOSUB D-SUB 25 Contact Inserts, Sleeve Housings Contact Inserts, Sleeve Housings Introduction VARIOSUB is a range of plug connectors specially designed for signal and data technology in an industrial environment with high degrees of protection, temperatures

More information

Operating voltages up to 40 kvdc Operating current up to 30 Amps Advanced contact technology Silver plated and gold plated contacts available High

Operating voltages up to 40 kvdc Operating current up to 30 Amps Advanced contact technology Silver plated and gold plated contacts available High Operating voltages up to 40 kvdc Operating current up to 30 Amps Advanced contact technology Silver plated and contacts available High performance insulation material General characteristics and technical

More information

Digital electropneumatic positioner

Digital electropneumatic positioner Digital electropneumatic positioner Type 879 can be combined with Compact metal housing Graphic display with backlight Easy start-up Comprehensive range of additional software functions Profibus DPV1 (optional)

More information

LMP 308. Separable Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO / 0.

LMP 308. Separable Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO / 0. LMP 08 Separable Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.25 % FSO / 0. % FSO Nominal pressure from 0... mh 2 O up to 0... 250 mh 2 O Output signals 2-wire:

More information

Standard Series Standard

Standard Series Standard Standard Series Standard Technical Data Coupler connector, cable connector and coupler connector rectangular housing Locking screw connection Protection IP 50 to IP 54 with conexil in the housing, flat-gasket

More information

ODU MINI-SNAP PC Product Description. ODU MINI-SNAP PC: The Connector with Push-Pull-Locking in Plastic

ODU MINI-SNAP PC Product Description. ODU MINI-SNAP PC: The Connector with Push-Pull-Locking in Plastic ODU MINI-SNAP PC Product Description ODU MINI-SNAP PC: The Connector with Push-Pull-Locking in Plastic Cylindrical Connectors are generally available with several locking mechanisms: The most frequently

More information

07. har-link Interface Connectors

07. har-link Interface Connectors . Interface Connectors The highest data rates in combination with perfect shielding characterize the connector. This way data can be passed on optimally within the control cabinet. The locking mechanism

More information

Level sensor Stainless steel version Model RLT-1000, for industrial applications

Level sensor Stainless steel version Model RLT-1000, for industrial applications Level measurement Level sensor Stainless steel version Model RLT-1000, for industrial applications WIKA data sheet LM 50.02 Applications Level measurement of liquids in machine building Control and monitoring

More information

PHOENIX CONTACT - 05/2007

PHOENIX CONTACT - 05/2007 Ex Universal Module Carrier (Motherboard) for Accommodating 3-Wire Measuring Transducers, Intrinsically Safe, for a Maximum of 8 PI Ex Modules INTERFACE Data Sheet 103030_00_en PHOENIX CONTACT - 05/2007

More information

Safety switches for hinged doors

Safety switches for hinged doors C Safety switches for hinged doors Selection diagram FR FM FX FZ FK 18 7 9 snap action overlapped CONTACT BLOCKS 21 NC 1NO+ CONDUIT ENTRIES Threaded conduit entries (standard) With cable gland assembled

More information

Level Transmitter. Table of dimensions see page 4. Total length B Installation length A SW55 Ø 55 Ø 75

Level Transmitter. Table of dimensions see page 4. Total length B Installation length A SW55 Ø 55 Ø 75 Level Transmitter Construction The GEMÜ level transmitter has an immersion tube with reed contacts and a chain of resistors which are triggered by a float with an integrated permanent magnet. A threaded

More information

Inductive sensor BI1.5-EG08-Y1-H1341

Inductive sensor BI1.5-EG08-Y1-H1341 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

SUBCON-PLUS-PROFIB...

SUBCON-PLUS-PROFIB... Fast connector for PROFIBUS systems Data sheet 101610_en_10 PHOENIX CONTACT 2017-03-27 1 Description The SUBCON-PLUS-PROFIB... D-SUB series is specifically designed for use in PROFIBUS systems up to 12

More information

SAC-5P-MS/ 1,0-920/FS SCO

SAC-5P-MS/ 1,0-920/FS SCO Extract from the online catalog SAC-5P-MS/ 1,0-920/FS SCO Order No.: 1518274 Bus system cable, DeviceNet/CANOpen, 5 pos., PUR halogen-free violet, shielded, straight M12 SPEEDCON connector on straight

More information

Extract from the online catalog

Extract from the online catalog Please note that the data given here has been taken from the online catalog. For comprehensive information and data, please refer to the user documentation at http://www.download.phoenixcontact.com. The

More information

Valve terminal RE-10 with Multi-pin, AS-Interface or bus connection 4 12 valve stations, 300 Nl/min (0.305 Cv)

Valve terminal RE-10 with Multi-pin, AS-Interface or bus connection 4 12 valve stations, 300 Nl/min (0.305 Cv) Type of connection = AS = B1 = B6 Order code RE-10/08-M-1-060 Series Number of stations Multi-pin: 4, 6, 8, 10, 12 Bus versions: 4, 8, 12 Electrical options M-1 = Multi-pin D-Sub plug AS3 = AS-Interface

More information

Cable Glands 757, BVE and 737 Series: Blanking Plugs, Adaptors and Reducers Increased Safety and Flameproof

Cable Glands 757, BVE and 737 Series: Blanking Plugs, Adaptors and Reducers Increased Safety and Flameproof 757 Series Blanking Plugs 737 Series Adaptors and Reducers BVE Series Plastic Blanking Plugs & Sealing Washers Compliance Data: 757 Series Blanking Plugs: ATEX IECEx CE Ex d IIC or Ex e II Ex td A21 IP

More information

Float switch For industrial applications Model RLS-1000

Float switch For industrial applications Model RLS-1000 Level measurement Float switch For industrial applications Model RLS-000 WIKA data sheet LM 50.0 Applications Level measurement of liquids in machine building Control and monitoring tasks for hydraulic

More information

Position Transducers Pivot head mounting potentiometric up to 300 mm, IP54 Series TEX

Position Transducers Pivot head mounting potentiometric up to 300 mm, IP54 Series TEX Position Transducers Pivot head mounting potentiometric up to 300 mm, IP54 Series TEX Special features compact dimensions protection class IP54 mountable over back-lash free pivot heads with a large angle

More information

UTME 6. Extract from the online catalog. Order No.:

UTME 6. Extract from the online catalog. Order No.: Extract from the online catalog UTME 6 Order No.: 3047400 Test disconnect terminal block, Connection method: Screw connection, Cross section: 0.2 mm² - 10 mm², AWG: 24-8, Width: 8.2 mm, Color: gray, Mounting

More information

modlink msdd Front panel interfaces

modlink msdd Front panel interfaces Tight and with full visibility The connecting mechanism of the Modlink MSDD with integrated locking mechanism allows the components to be used under protection class IP65. This protection class prevents

More information

Extract from the online catalog

Extract from the online catalog Please note that the data given here has been taken from the online catalog. For comprehensive information and data, please refer to the user documentation at http://www.download.phoenixcontact.com. The

More information

Inductive sensor with analog output BI15-M30-LI-EXI

Inductive sensor with analog output BI15-M30-LI-EXI ATEX category II 1 G, Ex-zone 0 ATEX category II 2 D, Ex-zone 21 Threaded barrel, M30 x 1.5 Chrome-plated brass Analog+ Extended operating range 2-wire, 14 30 VDC Analog output 4 20 ma Cable connection

More information

SACB-8/16-L-C GG SCO. Extract from the online catalog. Order No.:

SACB-8/16-L-C GG SCO. Extract from the online catalog. Order No.: Extract from the online catalog SACB-8/16-L-C GG SCO Order No.: 1516771 Sensor/actuator box header, Connection method: M12-SPEEDCONsocket, Number of slots: 8, Number of positions: 5, Slot assignment: Double,

More information

Operating Manual / IEC. Explosion-Proofed Junction Boxes, Polyester. Wallücker Bahndamm 7 DE Kirchlengern

Operating Manual / IEC. Explosion-Proofed Junction Boxes, Polyester. Wallücker Bahndamm 7 DE Kirchlengern Operating Manual / IEC Explosion-Proofed Junction Boxes, Polyester Wallücker Bahndamm 7 DE- 32278 Kirchlengern Tel.: +49 5223 49107-0 Fax: +49 5223 49107-28 info@multi-box.com www.multi-box.com Contents

More information

MBKKB 2,5-PV. Extract from the online catalog. Order No.:

MBKKB 2,5-PV. Extract from the online catalog. Order No.: Extract from the online catalog MBKKB 2,5-PV Order No.: 2800583 Mini double-level terminal block, with equipotential bonding between the levels, cross section: 0.2-2.5 mm², width: 5.2 mm, color: Gray Commercial

More information

07. har-link INTERFACE CONNECTORS

07. har-link INTERFACE CONNECTORS . INTERFACE CONNECTORS The highest data rates in combination with perfect shielding characterize the connector. This way data can be passed on optimally within the control cabinet. The locking mechanism

More information

Indicating Digital Transmitter for Differential Pressure and Flow. Media 6 with LCD Media 6 with LED

Indicating Digital Transmitter for Differential Pressure and Flow. Media 6 with LCD Media 6 with LED Indicating Digital Transmitter for Differential Pressure and Flow Media 6 with LCD Media 6 with LED Application Microprocessor-controlled transmitter for measuring and indicating the differential pressure

More information

UK 5 N BU. Extract from the online catalog. Order No.:

UK 5 N BU. Extract from the online catalog. Order No.: Extract from the online catalog UK 5 N BU Order No.: 3004388 Feed-through modular terminal block, Type of connection: Screw connection, Cross section: 0.2 mm² - 6 mm², AWG 24-10, Width: 6.2 mm, Color:

More information

Pneumatic Control/Feedback

Pneumatic Control/Feedback 897 /Feedback Type 897 can be combined with... Compact design Integrated pilot valve with manual override Internal control air routing Bright LED position indicator Automatic end position adjustment Type

More information

Data sheet * * Digital 2-channel transmitter for direct connection to bus-capable automation devices. Design and mode of operation

Data sheet * * Digital 2-channel transmitter for direct connection to bus-capable automation devices. Design and mode of operation d e v e l o p i n g s o l u t i o n s DE43 Data sheet Digital 2-channel transmitter for direct connection to bus-capable automation devices The bus-capable 2-channel transmitter is suitable for measuring

More information

ODU MAC LC. Modular Attachable Connector System

ODU MAC LC. Modular Attachable Connector System Catalogue No. 1004 LC-a ODU MAC LC Modular Attachable Connector System ODU Steckverbindungssysteme GmbH & Co. KG, Pregelstr. 11, 84453 Mühldorf a. Inn, Germany Phone: +49/ 86 31/61 56-0, Fax: +49/ 86 31/61

More information

M12 Field Wireable Connectors. M12 CAT.6A Field Wireable Connectors. M12 Field Wireable Connectors for PROFINET

M12 Field Wireable Connectors. M12 CAT.6A Field Wireable Connectors. M12 Field Wireable Connectors for PROFINET M12 Connectors Application Advantage Shielded design ETHERLINE Ethernet Cable, Connectors & Tools M12 Field Wireable Connectors Male Female Temperature Range: Max. 85 C Nominal Voltage: Nominal Current:

More information

Position Transducers Pivot head mounting potentiometric up to 300 mm, IP54 Series TEX

Position Transducers Pivot head mounting potentiometric up to 300 mm, IP54 Series TEX Position Transducers Pivot head mounting potentiometric up to 300 mm, IP54 Series TEX Special features compact dimensions protection class IP54 mountable over back-lash free pivot heads with a large angle

More information

Providing flexible power supply and signal connection there, where it is needed even in hazardous areas for the Zones 1and 2.

Providing flexible power supply and signal connection there, where it is needed even in hazardous areas for the Zones 1and 2. e X L i n k exlink 7-pole / 6-pole + PE for Zone 1 and Zone 21 Providing flexible power supply and signal connection there, where it is needed even in hazardous areas for the Zones 1and 2. The exlink 7

More information

Digital Positioner 8049

Digital Positioner 8049 Compact digital positioner for pneumatic control valves. Positioner can be integrated into valve actuator (no external moving parts for stroke feedback) Wide range of strokes - 8 mm No steady-state air

More information

Conveyor Belt Alignment Switches from IDEM

Conveyor Belt Alignment Switches from IDEM Conveyor Belt Alignment Switches from IDEM Data Sheet Die-Cast Models Python Line Series Stainless Steel Models Using Conveyor Belt Alignment Switches Application: Conveyor Belt Alignment switches are

More information

Program B3 318 Ø 22,5mm. Push Buttons 319 EMERGENCY STOP Buttons 320 Key Operated Rotary Switches 320

Program B3 318 Ø 22,5mm. Push Buttons 319 EMERGENCY STOP Buttons 320 Key Operated Rotary Switches 320 Push Buttons Index Page Program B3 318 Ø 22,5mm Push Buttons 319 EMERGENCY STOP Buttons 320 Key Operated Rotary Switches 320 Rotary Knobs and Swing Knobs 321 Illuminated Rotary Knobs and Swing Knobs 321

More information

3/2 Directional control valves Indirect controlled solenoid operated poppet valves Internal thread G1/2, 1/2 NPT or flanged with NAMUR interface

3/2 Directional control valves Indirect controlled solenoid operated poppet valves Internal thread G1/2, 1/2 NPT or flanged with NAMUR interface 9805 / Directional control valves Indirect controlled solenoid operated poppet valves Internal thread G/, / NPT or flanged with NMUR interface Main application: single operated process actuators TÜV-approval

More information

Ø 36 Ø 34 Ø 3,5 Ø 3,5

Ø 36 Ø 34 Ø 3,5 Ø 3,5 HEC English version locking system, 8 and contacts Degree of protection IP68/IP69K Crimp termination Diameter 6 mm VDE-, UL-approval Designed for harsh environments Description Male cable connector Drawing

More information

Supplementary instructions. Plug connector ISO for level sensors. Document ID: 30380

Supplementary instructions. Plug connector ISO for level sensors. Document ID: 30380 Supplementary instructions Plug connector ISO 4400 for level sensors Document ID: 30380 Contents Contents For your safety. Appropriate use... 3.2 General safety instructions... 3.3 Safety instructions

More information

Supplementary instructions. Plug connector ISO for continuously measuring sensors. Document ID: 30375

Supplementary instructions. Plug connector ISO for continuously measuring sensors. Document ID: 30375 Supplementary instructions Plug connector ISO 4400 for continuously measuring sensors Document ID: 30375 Contents Contents For your safety. Appropriate use... 3.2 Impermissible use... 3.3 General safety

More information

Resistance thermometer With spring-loaded tip Model TR55

Resistance thermometer With spring-loaded tip Model TR55 Temperature Resistance thermometer With spring-loaded tip Model TR55 WIKA data sheet TE 60.55 for further approvals see page 2 Applications Bearing temperature measurement on: Pumps Gears Motors Special

More information

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Rectangular, housing DSU35 Plastic, PP-GF30-VO Two outputs for monitoring the position of rotary actuators Mounting

More information

Product Overview Automation

Product Overview Automation EN DE Product Overview Automation Automation at a glance Ident Systems CIS3 CIS3A CIS3A - Mini Read system Read/write system Read system Read/write system Read system Read/write system Head Evaluation

More information

- 1 - General ordering data Order No

- 1 - General ordering data Order No General ordering data Order No. 1730710000 Part designation BL 5.00/3 SN SW Version EAN 4008190387327 Qty. 100 pc(s). System parameters Conductor connection system Leaf spring connection Outgoing direction

More information

TECHNICAL DATASHEET Absolute Encoder AC 58 - CANlayer2

TECHNICAL DATASHEET Absolute Encoder AC 58 - CANlayer2 Diagnostic LED Poll and auto mode Programmable: Direction, limit values Option: Display "tico" Clamping flange TECHNICAL DATA mechanical Housing diameter 58 mm Shaft diameter 6 mm / 10 mm (Solid shaft)

More information

PI-EX-ME-2NAM/COC-24VDC

PI-EX-ME-2NAM/COC-24VDC Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Relay Output, PDT, Two-Channel, 4 V DC Supply INTERFACE Data Sheet 0033_0_en PHOENIX CONTACT - /007 Description The PI-EX-ME-NAM/COC-4VDC

More information

Industrial Hydraulics FAQs

Industrial Hydraulics FAQs Industrial Hydraulics FAQs FAQ Title: Z versus K or K0 in model code Category: Proportional & Servo Valves Sub-Category: Directional Control Valves Bosch Rexroth Corporation Hydraulics 5 City Line Road

More information

KINAX WT720 absolute, programmable angular postion transmitter

KINAX WT720 absolute, programmable angular postion transmitter For industrial applications in rough environments KINAX WT720 is a robust, absolute angular position transmitter, which is particularly suited to applications in rough environments due to its unique capacitive

More information

Han PCB termination. Han-Fast Lock PCB adapter for Han DD PCB adapter for Han DDD module

Han PCB termination. Han-Fast Lock PCB adapter for Han DD PCB adapter for Han DDD module Han termination Contents Page Han-Fast Lock... 20.11 adapter for Han DD... 20.13 adapter for Han DDD module... 20.16 adapter for Han 40 A Axial module... 20.18 adapter for Han E... 20.20 adapter for Han

More information

Interfaces Service and Field

Interfaces Service and Field Interfaces Service and Field Front Panel Interfaces Interfaces Service Receptacles Cable Entry Systems 02 TRANSFORMATOREN 03 MODLINK MSDD THE CONNECTION TO THE OUTSIDE WORLD A safe bet MARKET REQUIREMENTS

More information

Supplementary instructions. Plug connector Harting HAN 7D. For point level sensors. Document ID: 34456

Supplementary instructions. Plug connector Harting HAN 7D. For point level sensors. Document ID: 34456 Supplementary instructions Plug connector Harting HAN 7D For point level sensors Document ID: 446 Contents Contents For your safety.... Appropriate use.... General safety instructions.... Safety instructions

More information

DT 2,5. Extract from the online catalog. Order No.:

DT 2,5. Extract from the online catalog. Order No.: Extract from the online catalog DT 2,5 Order No.: 3034028 Feed-through terminal blocks with auto spring connection, crosssection: 0.25-2.5 mm², width: 5.2 mm, color: Gray Commercial data EAN 4017918977443

More information

PT 2X2-24DC-ST. Extract from the online catalog. Order No.:

PT 2X2-24DC-ST. Extract from the online catalog. Order No.: Extract from the online catalog PT 2X2-24DC-ST Order No.: 2838228 The illustration shows version PT 2x2-5DC-ST Protective plug PT with protective circuit for two 2-core floating signal circuits. Nominal

More information

Digital electropneumatic positioner

Digital electropneumatic positioner Digital electropneumatic positioner Type 879 can be combined with Compact metal housing Graphic display with backlight Easy start-up Comprehensive range of additional software functions Profibus DPV1 (optional)

More information

Power supply unit NG3-16ib

Power supply unit NG3-16ib Ordering Data Designation Type Item no. Power supply unit NG3-16ib (42 V AC / ) 371 008 31 AX Power supply unit NG3-16ib (230 V AC / ) 371 008 32 AX Power supply unit NG3-16ib (100 V AC / ) 371 008 34

More information

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-EG08-Y1X-H1341

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-EG08-Y1X-H1341 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Rotary Measuring Technology

Rotary Measuring Technology Multiturn Type 8 Profibus-DP Very compact (only 87.8 mm installation depth); Ideal for dynamic applications thanks to its non-contact multiturn stage Solid shaft or blind hollow shaft Long service life

More information

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

MINI MCR-SL-UI-2I-NC. Extract from the online catalog. Order No.:

MINI MCR-SL-UI-2I-NC. Extract from the online catalog. Order No.: Extract from the online catalog MINI MCR-SL-UI-2I-NC Order No.: 2864176 4-way signal duplicator for electrical isolation and duplication of analog signals with screw connection, standard configuration

More information

Safety switches with separate actuator

Safety switches with separate actuator A Safety switches with separate actuator Selection diagram VF KEYF VF KEYF1 VF KEYF2 VF KEYF3 VF KEYF VF KEYF ACTUATORS CONTACT BLOCKS 9 snap action overlapped FD FP FL FC 21 22 33 3 3NC 2NO+1NC 1NO+ CONDUIT

More information

Datasheet DE DB_EN_DE44_LCD Rev. ST4-C 07/17. Digital 2-channel differential pressure switch/transmitter with colour-change LCD * *

Datasheet DE DB_EN_DE44_LCD Rev. ST4-C 07/17. Digital 2-channel differential pressure switch/transmitter with colour-change LCD * * 09005318 DB_EN_DE44_LCD Rev. ST4-C 07/17 *09005318* Datasheet DE44 Digital 2-channel differential pressure switch/transmitter with colour-change LCD 1 Product and functional description FISCHER Mess- und

More information

Vandal-proof latching action switch MSM LA

Vandal-proof latching action switch MSM LA Product Manual Vandal-proof latching action switch MSM LA CONTENTS 1 PRODUCT DESCRIPTION... 2 2 TECHNICAL DATA AND DIMENSIONAL DRAWINGS... 2 2.1 Technical Data... 2 2.2 Dimensional Drawings... 5 2.3 Hole

More information

Terminal Boxes Series 8118

Terminal Boxes Series 8118 > Enclosure made of glass fibre reinforced polyester resin > sizes available > Terminals and cable glands fitted to order > Enclosure design with integrated metal bracket for metal cable glands. > Degree

More information

Extract from the online catalog

Extract from the online catalog Please note that the data given here has been taken from the online catalog. For comprehensive information and data, please refer to the user documentation at http://www.download.phoenixcontact.com. The

More information

Waterproof Electrical Junction Box Kits Technical Data Sheet

Waterproof Electrical Junction Box Kits Technical Data Sheet Description Environmentally rated electrical junction box kits, that contain all necessary accessories to complete a straightforward neat wiring installation. Plastic enclosures are equipped with flexible

More information

TECHNICAL DATASHEET Absolute Encoder AC 58 - Profibus

TECHNICAL DATASHEET Absolute Encoder AC 58 - Profibus Diagnostic LED Cable or M12 connector Output of speed, acceleration Programmable: Resolution, Preset, Direction, Operation time Option: Display "tico" Address via interface parameterizable (optional) hubshaft

More information

Better all-round. DataVoice Circular connectors STX M12x1 IP67 Connector series for industrial applications. PoE+ 10 GBE. coded.

Better all-round. DataVoice Circular connectors STX M12x1 IP67 Connector series for industrial applications. PoE+ 10 GBE. coded. Better all-round. X coded D coded 10 GBE PoE+ DataVoice Circular connectors STX M12x1 IP67 Connector series for industrial applications STX M12x1 IP67 connector series With the STX M12x1 IP67 connector

More information

Position switches FD series

Position switches FD series Position switches FD series Selection diagram 01 08 11 18 19 0 04 05 Ø 8 mm Ø 1, mm external rubber stainless steel stainless steel glass fibre rod gasket sphere sphere 51 5 5 5 56 41 4 adjustable lever

More information

Multiturn absolute encoder

Multiturn absolute encoder Release date: 207-0-2 :0 Date of issue: 207-0-2 t79_eng.xml Model Number Features Industrial standard housing Ø58 mm PROFINET IRT 0 Bit multiturn Servo or clamping flange Network loop through by means

More information

fischer connectors 4032 Series HIGH-PERFORMANCE IN A VERSATILE PACKAGE MEDICAL PORTABLE EQUIPMENT DATA ACQUISITION INSTRUMENTATION Edition 1.

fischer connectors 4032 Series HIGH-PERFORMANCE IN A VERSATILE PACKAGE MEDICAL PORTABLE EQUIPMENT DATA ACQUISITION INSTRUMENTATION Edition 1. fischer connectors 4032 Series Plastic connectors Edition 1.2 MEDICAL PORTABLE EQUIPMENT DATA ACQUISITION HIGH-PERFORMANCE IN A VERSATILE PACKAGE INSTRUMENTATION PERFECT PACKAGE www.fischerconnectors.com

More information

Extract from the online catalog SFP 1-5/120AC Commercial data Product description Technical data Standards

Extract from the online catalog SFP 1-5/120AC Commercial data Product description Technical data Standards Extract from the online catalog SFP 1-5/120AC Order No.: 2920667 Device surge protection filter to limit powerful surge voltages, mounting on NS 35. Commercial data EAN 4046356158558 Pack 1 pcs. Customs

More information

Digital electropneumatic Positioner SideControl

Digital electropneumatic Positioner SideControl Digital electropneumatic Positioner SideControl Type 8791 BASIC can be combined with Compact and robust design Easy to start using tune function Dynamic positioning system with no air consumption in controlled

More information

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex-zone 20 for temperatures up to -25 C SIL2 acc. to IEC 61508 Rectangular, housing DSU35 Plastic, PP-GF30-VO Two outputs for monitoring the position

More information

Cable Glands. Description Introduction to Cable Glands 399. EEXe Series EEXe Series. A2F, E1FX/E2FX, E1FW/E2FW and T3 Series

Cable Glands. Description Introduction to Cable Glands 399. EEXe Series EEXe Series. A2F, E1FX/E2FX, E1FW/E2FW and T3 Series Description Page Introduction to Cable Glands 399 EEXe Series 400-401 Polyamide Cable Glands for Unarmored Cable Increased Safety EEXe Series Ex e Certified Ex I Application Entry Thread Seal A2F, E1FX/E2FX,

More information

07. har-link Interface Connectors

07. har-link Interface Connectors . Interface Connectors The highest data rates in combination with perfect shielding characterize the connector. This way data can be passed on optimally within the control cabinet. The locking mechanism

More information