Building method. Exclusive mating cable for SF-C14EX(-01) SF4B series Muting sensor. Less wiring!

Size: px
Start display at page:

Download "Building method. Exclusive mating cable for SF-C14EX(-01) SF4B series Muting sensor. Less wiring!"

Transcription

1 Exclusive Control Unit for Light Curtain SERIES Related Information General terms and conditions... F- SFB / SFB-G... P.0~ General precautions... P.9 SFD... P.9~ SFC / SFB...P.77~ / P.0~ Korea s S-mark... P.0 PHOTO PHOTO Certified Listing Certified (SF-C/C only) MEASURE Category PLe SIL panasonic.net/id/pidsx/global The control category differs depending on the configuration and wiring of the external circuit. Less setup time for safety circuits Plug-in type control unit Quick-connection Connecting to the safety light curtain is done using plug-in connections, which shortens setup and replacement time. Easy setup requiring no torque control A spring method is used for the terminal blocks for connections other than to the safety light curtain. There is no need to control tightening torques for these terminal blocks. Flat-tipped screwdriver Lead wire Ferrule (sleeve) terminal (Please arrange separately.) Removable terminal blocks reduce maintenance time Removable terminal blocks are used. This reduces the work required for reconnecting wiring during maintenance. Removable! SF-C / SF-CEX(-0) Light Uses a spring method! Release button Lead wire insertion hole Robust type control unit SF-C Slim type control unit SF-C Metal enclosure with a IP protective structure The strong metal enclosure has a built-in safety relay. It has an IP protective structure, so that it can be set up individually without needing to be inserted into a control panel. IP Metal enclosure Slim design. mm 0.88 in thickness, so can be inserted even into narrow spaces inside panels. Slim. mm 0.88 in The wiring with the safety light curtain is connection. Spring-type terminal block No torque control needed

2 Exclusive Control Unit for Light Curtain SERIES Building of muting control circuits is easy The method used to build the safety circuit is selectable It is possible to build muting control circuits using a stand-alone safety light curtain from the SFB / SFB-G series. The SF-CEX(-0) application expansion unit allows the safety light curtain, muting sensors and muting lamps to be connected together directly, so that muting control circuits can be built very easily. Building method SFB series Muting sensors Using SFB series functions Muting control Terminal blocks Muting lamps No safety relay unit needed Low cost! Saves space! output External devices (Force-guided relay, etc.) Motor, etc. Three safety circuit systems packaged into a single unit! Three safety circuit systems light curtain output circuit, Muting control circuit, and Emergency stop circuit are packaged into a single unit. Functions that require multiple safety relay units and muting control units can be concentrated into a single unit, which results in large space savings, less wiring and less installation work. Previous model light curtain Muting sensor Emergency stop button relay unit Muting unit relay unit SF-CEX(-0) SFB series Muting sensor Emergency stop button Saves space! Less wiring! Less construction! Building method SFB series Furthermore, due to the semiconductor output, Muting sensors Exclusive mating cable for SF-CEX(-0) Less wiring! Using the SF-CEX(-0) internal circuits Muting control SF-CEX(-0) light curtain connection. Terminal blocks for peripheral circuits available. Muting lamps Reduced maintenance! output External devices (Force-guided relay, etc.) Motor, etc. High-speed response ms (Including safety light curtain) High-speed response has been achieved due to the adoption of the semiconductor output. Avoids the response delays that occur when using more than one safety relay unit, and greatly reduces the safety light curtain safety distance and improves ease of working. Of course, it is not necessary to exchange the safety relays within the unit anymore, which contributes to the reduction of running cost. Including safety light curtain response time High response speed of ms! Greatly reduced safety distance! Previous model ms 0 ms 0 ms ms SF-CEX(-0) Both safety and productivity can be obtained by stopping only one part of the device SF-CEX(-0) Customer's logical connection circuit PHOTO PHOTO MEASURE Light Customer's logical connection circuit External contactor (Force-guided relay, etc.) SF-CEX(-0) External contactor (Force-guided relay, etc.) SF-CEX(-0) Total ms! Relay replacement is not required! Motor Motor light curtain output circuit Muting control circuit Emergency stop circuit

3 Exclusive Control Unit for Light Curtain SERIES PHOTO PHOTO MEASURE Three safety circuit systems can be controlled independently so that equipment can be stopped all together or partially SF-CEX(-0) Motors that use muting control and those that do not use it can be controlled independently! Controls the motors that use muting control (robots) and the motors that do not use muting control (turntables) with a single unit. When the workpiece comes in, the turntable can be stopped and the robot can keep operating condition, to protect the safety of the operator and to maintain productivity. circuit : Linked to safety light curtain beam received / interrupted status (partial stop) When the safety light curtain is interrupted (when an workpiece enters or a person intrudes), this circuit switches off (open) the safety output and stops the turntable. circuit : Linked to muting control (partial stop) If an workpiece enters when the turntable has stopped normally, (muting conditions are achieved), this circuit allows the robot to operate. If an workpiece enters while the turntable is turning (muting conditions are not achieved), this circuit switches off (open) the safety output and stops the robot. circuit : Linked to emergency stop input (all stop) When the emergency stop button is pressed, this circuit switches off (open) the safety output and stops all equipment (turntable and robot). Emergency stop button SFB series SF-CEX(-0) controls three safety output systems using only a single unit! Turntable Motor not using muting Robot Motor using muting Limit switch For muting input Equipped with blown lamp output for muting lamp If a lamp in one of the two muting lamps that are connected to the unit blows, a warning is output. It is possible to replace the lamp before both lamps blow and the equipment stops. In addition, auxiliary output that is linked to the muting function, override function and safety light curtain control output is also available. Equipped with a digital indicator so that error details can be understood at a glance! If a problem should occur, the same output ( signal) as when the object was detected is maintained in order to ensure safety, and the details of the error appear on the digital display. Light Auxiliary output Auxiliary output Auxiliary output Auxiliary output Function Muting output Override output Blown lamp output light curtain auxiliary output Operation ON when the muting function is invalid ON when the override function is invalid ON when the muting lamp is normal ON when the safety light curtain is in light interrupted condition Supports both PNP and NPN polarities All Models A single model can be used for PNP/NPN input switching, reducing the number of parts that need to be registered. NPN PNP Polarity selection switch

4 Exclusive Control Unit for Light Curtain SERIES ORDER GUIDE Designation Appearance Model No. Applicable cable (Note) Description Connector connection type control unit Robust type control unit SF-C SF-C light curtain connection cable: SFB-CB (For SFB series) SFB-CB (For SFB series) Extension cable: SFB-CCJ0 light curtain connection cable: SFB-CB0-MU Extension cable: SFB-CCJ0 -MU Use 8-core cable with to connect to the safety light curtain. Compatible with up to Control Category. Interference prevention wires and muting function cannot be used. Use -core cable with to connect to the safety light curtain. Interference prevention wires can be used. Compatible with up to Control Category. Muting function cannot be used. Slim type control unit SF-C light curtain connection cable: SFB-CCB (-MU) (For SFB series) SFB-CCB (For SFB series) Extension cable: SFB-CC (-MU) Use a discrete wire cable to connect to the safety light curtain. Muting function and interference prevention wires can be used. Compatible with up to Control Category. Application expansion unit for SFB / SFB-G series Handy-controller non-compatible type Note: Refer to SFB / SFB-G series pages (p.~) and SFB series pages (p.08) for the applicable cable. SF-C spare relay set SF-CEX SF-CEX-0 light curtain connection cable: SFB-CB -EX Extension cable: SFB-CCJ0 A set of spare relays ( safety relays and removal tool) is available for the safety relay that is built into the SF-C. Model No.: SF-C-RY The muting control function and emergency stop input expand the applications of the safety light curtains. Use exclusive cable to connect to the safety light curtain. Compatible with up to Control Category. The handy-controller SFB-HC (optional) cannot be used with SF-CEX-0. Light

5 7 Exclusive Control Unit for Light Curtain SERIES SPECIFICATIONS Light Model No. Item SF-C SF-C SF-C Connectable safety light curtains SFD / SFB / SFB-G / SFB series SFB / SFB-G series light curtain manufactured by Panasonic Industrial Devices SUNX Applicable standards CE marking directive compliance Control category Supply voltage / Current consumption Fuse rating EN 9- (Type ), EN 0, EN ISO 89- (Category, PLe), IEC 9- (Type ), ISO 89- (Category, PLe), JIS B 970- (Type ), JIS B 970-(Category ), ANSI/UL 9- (Type ), UL 998 (Class ) (Note ) Machinery Directive, Low Voltage (SF-C/C only) Directive, EMC Directive, RoHS Directive ISO 89- (EN ISO 89-, JIS B 970-) compliance up to Category, PLe standards V DC ±0 % Ripple P-P 0 % or less / 00 ma or less (without safety light curtain) Built-in electronic fuse, Triggering current: 0. A or more, Reset after power down output NO contact (-, -, -) NO contact (-, -) NO contact (-, -, -) Utilization AC-, DC- (IEC 097--) Rated operation voltage (Ue) / Rated operation current (le) DC / A, AC / A, resistive load V DC / A, resistive load DC / A, AC / A, resistive load (For inductive load, during contact protection) (For inductive load, during contact protection) (For inductive load, during contact protection) Min. applicable load: 0 ma (at V DC) (Note ) Min. applicable load: ma (at V DC) Min. applicable load: 0 ma (at V DC) (Note ) Contact material / contacts AgSnO, self cleaning, positively driven AgNiO + 0. µm mil Au plating, self cleaning, positively driven AgSnO, self cleaning, positively driven Contact resistance 00 mω or less (initial value) 0 mω or less (initial value) 00 mω or less (initial value) Contact protection fuse rating A (slow blow) A (slow blow) A (slow blow) Mechanical lifetime 0,000,000 times or more (open/close frequency of 80 times/min) (Note ) Electrical lifetime 00,000 times or more (open/close frequency of 0 times/min, AC, A, using resistance load) (Note ) Pick-up delay (Auto reset/manual reset) 80 ms or less / 90 ms or less 0 ms or less / 0 ms or less 80 ms or less / 90 ms or less Response time 0 ms or less ms or less 0 ms or less Auxiliary output relay contact (NC contact) (-) (Related to enabling path) relay contact (NC contact) (-) (Related to enabling path) relay contact (NC contact) (-) (Related to enabling path) Rated operation voltage/current V DC / A, Min. applicable load: 0 ma (at V DC) DC / A, Min. applicable load: ma (at V DC) V DC / A, Min. applicable load: 0 ma (at V DC) Contact protection fuse rating A (slow blow) A (slow blow) A (slow blow) Semiconductor auxiliary output () <Minus ground (Setting for PNP)> PNP open-collector transistor Max. source current: 0 ma Applied voltage: same as supply voltage between the semiconductor auxiliary output and +V Residual voltage:. V or less (at source current 0 ma) Leakage current: ma or less <Plus ground (Setting for NPN)> NPN open-collector transistor Max. sink current: 0 ma Applied voltage: same as supply voltage between the semiconductor auxiliary output and Residual voltage:. V or less (at sink current 0 ma) Leakage current: ma or less PNP open collector transistor Max. source current: 0 ma Applied voltage: same as supply voltage between the semiconductor auxiliary output and +V Residual voltage:. V or less (at source current 0 ma) Leakage current: ma or less Output operation Related to auxiliary output of safety light curtain On when the safety light curtain is interrupted Excess voltage category ll lll ll Power supply (Ui) Green LED (lights up when the power is ON) output [OUT (Note )] Green LED (lights up when safety output is closed) Interlock (INTER_LOCK) Yellow LED (lights up when safety output is opened) Yellow LED (lights up when enabling contacts are opened) Fault (ULT) Yellow LED (blinks when fault occurs) Orange LED (lights up when two safety light curtain input polarity selection switch settings are different) Yellow LED (blinks when fault occurs) External relay monitor function Incorporated Incorporated (Note ) Incorporated Trailing edge function Incorporated Indicators Polarity selection function (Note 7) Incorporated (Sliding switch allows selection of plus/minus ground) Minus ground: Correspond to PNP output safety light curtain Plus ground: Correspond to NPN output safety light curtain Incorporated (Cable connection allows selection of plus/minus ground) Minus ground: Correspond to PNP output safety light curtain Plus ground: Correspond to NPN output safety light curtain Pollution degree Protection Enclosure: IP0, Terminal: IP0 IP Enclosure: IP0, Terminal: IP0 Ambient temperature 0 to + C + to + F (No dew condensation or icing allowed), Storage: to +70 C to +8 F Ambient humidity 0 to 8 % RH, Storage: 0 to 9 % RH to 8 % RH, Storage: to 8 % RH 0 to 8 % RH, Storage: 0 to 9 % RH Environmental resistance Vibration resistance Resistance / malfunction 0 to Hz frequency, 0. mm 0.0 in amplitude in X, Y, and Z directions for twenty times each Resistance 0 to Hz frequency, 0.7 mm 0.00 in Resistance / malfunction 0 to Hz frequency, 0. mm 0.0 in amplitude in X, Y, and Z directions for two hours each amplitude in X, Y, and Z directions for twenty times each Connection terminal Detachable spring-cage terminal European terminal Spring-cage terminal Enclosure material ABS Die-cast aluminum ABS Weight Net weight: 0 g approx. Net weight: kg approx. Net weight: 00 g approx. Notes: ) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +0 C +8 F. ) SF-C and SF-C comply with UL 998 (Class ). ) If several SF-C or SF-C units are being used in line together, leave a space of mm 0.97 in or more between each unit. If the units are touching each other, reduce the rated operating current for safety output in accordance with the ambient operating temperature as shown in the graphs at right. ) The life expectancy of the relay varies depending on the type of load, open / close frequency, ambient conditions and others. ) The operation indicator is marked as Enabling on the unit for SF-C. ) Terminals for utilizing the functions of the SFB / SFB-G series are available. 7) Please switch the sliding switch to the PNP side for minus ground and to the NPN side for plus ground. Dilating when SF-C units are mounted close together Rated operation current (A) Ambient temperature ( C F) Dilating when SF-C units are mounted close together Rated operation current (A) Ambient temperature ( C F)

6 Exclusive Control Unit for Light Curtain SERIES 8 SPECIFICATIONS Model No. Item SF-CEX(-0) (Note ) Connectable safety light curtains Applicable standards CE marking directive compliance Control category Supply voltage Current consumption outputs output output output Operation mode (Output operation) Protection circuit (Short-circuit protection) Response time Auxiliary outputs Auxiliary output Auxiliary output Auxiliary output Auxiliary output (Note ) Operation mode (Output operation) Protection circuit (Short-circuit protection) Muting lamp output Protection circuit (Short-circuit protection) SFB / SFB-G series IEC 9- (Type ), EN 0, EN ISO 89- (Category, PLe), IEC 9 (Type ), ISO 89- (Category, PLe), JIS B 970- (Type ), JIS B 970- (Category, PLe), ANSI/UL 9- (Type ), UL 998 (Class ) Machinery Directive, EMC Directive, RoHS Directive ISO 89- (EN ISO 89-, JIS B 970-) compliance up to Category, PLe standards V DC ±0 % Ripple P-P 0 % or less 0. A or less (Excluding safety light curtain and other external connecting device) PNP open-collector transistor outputs or NPN open-collector transistor outputs (selectable using a slider switch) <When PNP output is selected> <When NPN output is selected> Maximum source current: 00 ma Maximum sink current: 00 ma Applied voltage: same as supply voltage Applied voltage: same as supply voltage (between the safety output and +V) (between the safety output and ) Residual voltage: V or less (at 00 ma source current) Residual voltage: V or less (at 00 ma sink current) output : ON when the safety light curtain is in light receiving condition, when the safety light curtain is in light interrupted condition (Note ) output : ON when the safety light curtain is in light receiving condition or the muting function is valid when the safety light curtain is in light interrupted condition and the muting function is invalid (Note ) output : ON when the emergency stop is invalid, when the emergency stop is valid Incorporated response: ms or less ( output and : including the response time of the safety light curtain) ON response: 90 ms or less (auto-reset) / 0 ms or less (manual reset) (Note ) PNP open-collector transistor or NPN open-collector transistor (selectable using a slider switch) <When PNP output is selected> <When NPN output is selected> Maximum source current: 0 ma Maximum sink current: 0 ma Applied voltage: same as supply voltage Applied voltage: same as supply voltage (between the auxiliary output and +V) (between the auxiliary output and ) Residual voltage: V or less (at 0 ma source current) Residual voltage: V or less (at 0 ma sink current) Auxiliary output : ON when the muting function is invalid, when the muting function is valid Auxiliary output : ON when the override function is invalid, when the override function is valid Auxiliary output : ON when the muting lamp is normal, when the muting lamp is error Auxiliary output : ON when the safety light curtain is in light interrupted condition, when the safety light curtain is in light receiving condition (Note ) Incorporated Applicable muting lamp: V DC,. to 0 W (L, L of each unit) Incorporated PFHD (Note ). 0-0 MTTFD (Note ) 00 years or more Environmental resistance Protection Enclosure: IP0, Terminal: IP0 Ambient temperature 0 to + C + to + F (No dew condensation or icing allowed), Storage: to +70 C to +8 F Ambient humidity 0 to 8 % RH, Storage: 0 to 9 % RH Dielectric strength voltage,00 AC for one min. between all supply terminals connected together and enclosure Insulation resistance 0 MΩ, or more, with 0 DC megger between all supply terminals connected together and enclosure Vibration resistance 0 to Hz frequency, 0. mm 0.0 in double amplitude in X, Y and Z directions for two hours each Shock resistance 0 G acceleration in X, Y and Z directions three times each Light Material Connection terminal Enclosure: ABS Detachable spring-cage terminal Weight Net weight: 0 g approx. Notes: ) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +0 C +8 F. ) The handy-controller SFB-HC (optional) cannot be used with SF-CEX-0. ) Both safety output and are when the emergency stop is valid regardless of whether the safety light curtain is in the light receiving or light interrupted condition. ) The auto-reset cannot be used with safety output. ) The auxiliary output incorporated in the SFB / SFB-G series is output. ) PFHD: Probability of dangerous failure per hour, MTTFD: Mean time to dangerous failure (in years)

7 9 Exclusive Control Unit for Light Curtain SERIES Light CURTAIN WIRING DIAGRAMS Wiring diagram of SF-C and SFB / SFB-G series or SFB series (Control Category or ) For PNP output (minus ground) Set the safety light curtain input polarity selection switch to the PNP side and ground the line. light curtain input polarity selection switch + V DC A F.G. A RESET (Note ) (Note ) (Note ) X X X A B Ui F T TEST (Note ) SF-C control circuit OUT INTER_LOCK NPN PNP L F K K ULT F T, KB: Magnet contactor KB N L L L KB Notes: ) The above diagram is when using manual reset. If automatic reset is used, disconnect the lead from X and connect it to X. In this case, a reset (RESET) button is not needed. ) Use a momentary-type switch as the reset (RESET) button. ) Emission halt occurs when the test (TEST) button is open, and emission occurs when the test (TEST) button is short-circuited. If not using the test (TEST) button, short-circuit T and T. However, in case of SFB series, use a test rod or similar to interrupt the light in order to carry out self-diagnosis separately. For NPN output (plus ground) In the above diagram, set the safety light curtain input polarity selection switch to the NPN side and ground the + side. Wiring diagram of SF-C and SFB / SFB-G series (Control Category ) For PNP output (minus ground) Set the two safety light curtain input polarity selection switches to the PNP side and connect the F.G. terminal to the line. Emission halt input switch (Note) (Note) Interference prevention wire MPCE MPCE F F + V DC RESET F.G. A X X X A B A X X T T E E+ R R+ FB FB FB FB A A FG Ui F NPN SF-C control circuit T TEST PNP INTER_LOCK M light curtain input polarity selection switch OUT T NPN PNP ULT light curtain input polarity selection switches When connecting the SF-C to the safety light curtains, make sure to use the 8-core connection cable with a. Refer to the SFB / SFB-G series and SFB series pages for details. SFB-CB, SFB-CB, SFB-CCJ0 Terminal arrangement diagram Terminal Function A + V DC A -, -, - output (NO contact ) - Auxiliary output (NC contact ) X Reset output terminal X Reset input terminal (Manual) X Reset input terminal (Automatic) A B Not used T Test output terminal T Test input terminal Semiconductor auxiliary output Pin layout for safety light curtain s 8 7 Connector pin No. Interlock (Note) OSSD + V DC + V DC Emission halt OSSD Auxiliary output EDM (External relay monitor) Synchronization wire + Synchronization wire + Synchronization wire Synchronization wire 7 8 Shielded wire Shielded wire Note: It is not used with the SFB series. When connecting the SF-C to the safety light curtains, make sure to use the -core connection cable with a. Refer to the SFB / SFB-G series pages for details. SFB-CB0-MU (Cable length: 0. m.0 ft) SFB-CCJ0E-MU (Extension cable for emitter, cable length: 0 m.808 ft) SFB-CCJ0D-MU (Extension cable for receiver, cable length: 0 m.808 ft) Terminal arrangement diagram Terminal Function FG Frame ground (F.G.) terminal A A + V DC -, - output (NO contact ) - Auxiliary output (NC contact ) FB External relay monitor FB terminal FB FB External relay monitor terminal X X T T E- E+ R- R+ FB FB FB FB A A FG Terminal Function R+ Interference prevention wire () R Interference prevention wire + () E+ Interference prevention wire () E Interference prevention wire + () T Emission halt input T terminal X X Automatic reset/manual reset selection terminal Manual reset: X X short-circuited output Auxiliary Power input output V DC ±0 % Note: The above diagram is when using manual reset. If automatic reset is used, connect a normal close-type pushbutton switch between T and T and leave between X and X open. For NPN output (plus ground) In the above diagram, set the two safety light curtain input polarity selection switches to the NPN side and connect the F.G. terminal to the + side. Pin layout for safety light curtain s Note: Input and output for pin Nos. and are not used by this product Connector pin No. Interlock OSSD + V DC + V DC Emission halt OSSD Auxiliary output EDM (External relay monitor) Synchronization wire + Synchronization wire + Synchronization wire Synchronization wire 7 8 Shielded wire Shielded wire 9 Interference prevention wire + Interference prevention wire + 0 Interference prevention wire Interference prevention wire (Override input) (Muting input ) (Muting lamp output) (Muting input )

8 Exclusive Control Unit for Light Curtain SERIES 70 CURTAIN WIRING DIAGRAMS Wiring diagram of SF-C and SFB / SFB-G series or SFB series (Control Category or ) For PNP output (minus ground) Connect the safety light curtain control outputs OSSD and OSSD to S and S respectively. A A Emitter Cable color: Gray +V (Brown) (Orange) Synchronization + + V DC (Orange / Black) Synchronization Output polarity Emission halt Auxiliary output Interlock setting input setting wire input / Reset input (Yellow-green / (Pale purple) (Note ) Open Output (Shield) (Note ) (Pink) (Note ) Black) +V (Brown) polarity setting wire Load (Shield) (Blue) (Blue) (Note ) External device monitoring input (Yellow-green) OSSD (Black) OSSD (White) L RESET (Note, ) S S S S X X X Receiver Cable color: Gray with black line (Note ) F F F K Ui SF-C control circuit K OUT INTER_LOCK ULT L L L F.G., KB: Magnet contactor KB N M Notes: ) The above diagram is when using manual reset. If automatic reset is used, disconnect the lead from X and connect it to X. In this case, a reset (RESET) button is not needed. ) Use a momentary-type switch as the reset (RESET) button. ) This is a test input (pink) for the SFB series. ) This is not equipped on the SFB series. ) This is a shield for the SFB series. Terminal arrangement diagram KB For NPN output (plus ground) Connect the safety light curtain control outputs OSSD and OSSD to S and S respectively and ground the + side. + V DC +V (Brown) F.G. A Emitter Output Emission halt Auxiliary output Interlock setting input polarity input / Reset input (Yellow-green / (Pale purple) (Note ) Output setting wire (Pink) (Note ) Black) polarity Open (Shield) (Note ) +V setting wire (Blue) Load (Brown) (Shield) (Note ) (Blue) A Ui F S Cable color: Gray External device monitoring input (Yellow-green) S S S SF-C control circuit OUT (Orange) Synchronization + (Orange / Black) Synchronization, KB: Magnet contactor L X X X INTER_LOCK (Note ) F K K ULT N Receiver Cable color: Gray with black line OSSD (White) OSSD (Black) F KB RESET (Note, ) L L L Notes: ) The above diagram is when using manual reset. If automatic reset is used, disconnect the lead from X and connect it to X. In this case, a reset (RESET) button is not needed. ) Use a momentary-type switch as the reset (RESET) button. ) This is a test input (pink) for the SFB series. ) This is not equipped on the SFB series. ) This is a shield for the SFB series. M KB A A S S S S X X X Terminal A A S to S X X X -, -, - + V DC Function light curtain control output (OSSD) input terminal Semiconductor auxiliary output Reset output terminal Reset input terminal (Manual) Reset input terminal (Automatic) output (NO contact ) - Auxiliary output (NC contact ) When connecting the SF-C to the safety light curtains, make sure to use a discrete wire connection cable. Refer to the SFB / SFB-G series and SFB series pages for details. SFB-CCB (-MU), SFB-CCB, SFB-CC (-MU) Light Use a separate terminal block to carry out wiring for safety light curtains that cannot be connected to the SF-C.

9 7 Exclusive Control Unit for Light Curtain SERIES CURTAIN WIRING DIAGRAMS Wiring diagram of SF-CEX(-0) and SFB / SFB-G series (Control Category ) For PNP output (minus ground) Set the output polarity selection switch to the PNP side and ground the line. Emergency stop switch + V DC (Note ) RESET KB (Note ) etc. A S S S S X X X X X X X X IE+ IE IR+ IR NPN Output polarity selection switch PNP SF-CEX(-0) control circuit A S+ S S S+ S S T T O O L+ L L+ L +V OUT 0V +V OUT 0V KB KD KF F.G. KC KE TEST Muting sensor Muting sensor (PNP output type) (NPN output type) Override input (Note ) KC RESET KD (Note ) Muting lamp output. to 0 W KE RESET KF (Note ) Muting lamp output. to 0 W to KF: Force-guided relay or magnet contactors. When connecting the SF-CEX to the safety light curtains, make sure to use the following connecting cable. SFB-CB0-EX (Cable length: 0. m.0 ft) SFB-CB-EX (Cable length: m.0 ft) SFB-CB0-EX (Cable length: 0 m.808 ft) If the NO (Normally Open) contact switch is used as a muting sensor, wire it as shown in the figure below. S+ S S S+ S S If the emergency stop switch is not used, short-circuit between the terminals S to S and S to S directly. Notes: ) The above diagram is when using manual reset. If automatic reset is used, disconnect the lead from X and X, and connect them to X and X as shown by the dotted lines. In this case, a reset (RESET) button is not needed. Terminals X to X are for manual reset only. ) Use a momentary-type switch for the reset (RESET) button. For NPN output (plus ground) Set the output polarity selection switch to the NPN side and ground the + side of the power supply input. Emergency stop switch + V DC F.G. (Note ) RESET KB (Note ) (Note ) KC RESET KD (Note ) KE RESET KF (Note ) etc. A S S S S X X X X X X X X IE+ IE IR+ IR NPN Output polarity selection switch PNP SF-CEX(-0) control circuit A S+ S S S+ S S T T O O L+ L L+ L +V OUT 0V +V OUT 0V KB KD KF KC KE TEST Muting sensor Muting sensor V (PNP output type) (NPN output type) Muting lamp Muting lamp output output Override input. to 0 W. to 0 W to KF: Force-guided relay or magnet contactors. Notes: ) The left diagram is when using manual reset. If automatic reset is used, disconnect the lead from X and X, and connect them to X and X as shown by the dotted lines. In this case, a reset (RESET) button is not needed. Terminals X to X are for manual reset only. ) Use a momentary-type switch for the reset (RESET) button. Light Terminal arrangement diagram Terminal Function Terminal Function output, Light received S Emergency stop / Light interrupted output of contact input the safety light curtain S NC input output, light S curtain output including the Between S and S muting function S Between S and S output X output reset input Emergency stop output X X - X: Manual reset S+ Muting sensor input X X - X: Auto-reset S (PNP output type) S+, S : Power supply X output reset input S S: Sensor output X X - X: Manual reset S+ Muting sensor input X X - X: Auto-reset (NPN output type) S X S+, S : Power supply output reset input S S: Sensor output X X - X: Manual reset T Test input terminal Auxiliary output, Muting output Open: Test mode T Short-circuit: Normal operation Auxiliary output, Override output O Override input terminal Auxiliary output, Blown lamp output Open: Invalid O Short-circuit: Valid Auxiliary output, light curtain auxiliary output L+ Muting lamp output IE+ Interference prevention terminal, + L IE Interference prevention terminal, L+ Muting lamp output IR+ Interference prevention terminal, + L IR Interference prevention terminal, A + V DC A Pin layout for safety light curtain s Connector pin No. 8 7 Interference Interference prevention wire + prevention wire + + V DC + V DC Interference prevention wire Interference prevention wire Auxiliary output Not used Synchronization wire + Synchronization wire 7 Synchronization wire + Synchronization wire 8 Shielded wire Shielded wire

10 Exclusive Control Unit for Light Curtain SERIES 7 PRECAUTIONS FOR PROPER Refer to p.9 for general precautions. Part description and function [SF-CEX(-0)] 8 output indicator (OUT)(Green) Digital indicator (Red) Power indicator (Ui) (Green) Muting sensor indicator (MU)(Orange) Test input indicator (TEST)(Yellow) 7 Muting sensor indicator (MU)(Orange) 9 output indicator (OUT)(Green) 0 output indicator (OUT)(Green) No. Description Function Interlock indicator (INTER LOCK)(Yellow) Auxiliary output indicator ()(Orange) Output polarity selection switch Auxiliary output indicator ()(Orange) Interlock indicator (INTER LOCK)(Yellow) Auxiliary output indicator ()(Orange) 7 Interlock indicator (INTER LOCK)(Yellow) The emitter of SFB / SFB-G series is connected. The receiver of SFB / SFB-G series is connected. Digital indicator (Red) Lights up or blinks when there is a problem. Lights up when blanking function is enabled. Power indicator (Ui) (Green) Lights up when the power is ON. Test input indicator (TEST) (Yellow) Lights up when test input is enabled. Blinks while communication with SFB-HC (optional) handy-controller is in progress. (Excluding SF-CEX-0) Muting sensor indicator (MU) (Orange) Lights up when muting sensor is ON. 7 Muting sensor indicator (MU) (Orange) Lights up when muting sensor is ON. 8 output indicator (OUT) (Green) Lights up when safety output is ON. 9 output indicator (OUT) (Green) Lights up when safety output is ON. 0 output indicator (OUT) (Green) Lights up when safety output is ON. Output polarity selection switch PNP (minus ground) or NPN (plus ground) can be selected. The factory setting is PNP (minus ground). Auxiliary output indicator () (Orange) Lights up when auxiliary output is ON. Auxiliary output indicator () (Orange) Lights up when auxiliary output is ON. Auxiliary output indicator () (Orange) Lights up when auxiliary output is ON. Interlock indicator (INTER LOCK) (Yellow) Lights up when interlock is ON. Interlock indicator (INTER LOCK) (Yellow) Lights up when interlock is ON. 7 Interlock indicator (INTER LOCK) (Yellow) Lights up when interlock is ON. Wiring The following solid wire and twisted wires (lead wire) are recommended. SF-C Power supply and output line : 0. to. mm (AWG to ) Signal line : 0. to. mm (AWG to ) SF-C Single wire: ø0. to ø. mm ø0.0 to ø0.07 in (AWG to ) Twisted wire (lead wire): 0. to. mm (AWG to ) SF-CEX(-0) Power supply line (A, A): 0. to. mm (AWG to ) Other s: 0. to. mm (AWG to ) Output waveform ( output ON) [SF-CEX(-0)] When safety output is ON, self-diagnosis of the output circuit is carried out, so that the output transistor will periodically turn. ( pulse width: 00 µs or less) When the signal is fed back, the receiver judges the output circuit as normal. When the signal is not fed back, the receiver judges either the output circuit or wiring as error, and the safety output maintains status. Since the signal of SF-CEX(-0) might cause malfunction, perform the connecting paying attention to the input response time of the machine to be connected to SF-CEX(-0). Time chart [SF-CEX(-0)] Normal operation The diagram shows operation with safety outputs and in manual-reset mode. Light received light curtain Light interrupted Invalid Emergency stop Valid ON Muting sensor Muting sensor ON ON Reset input ON Reset input ON Reset input output ON (, ) output ON (, ) output ON (, ) Auxiliary output ON (Muting output) Auxiliary output ON (Auxiliary output of safety light curtain) Muting lamp ON output / 0 to sec. 0 to sec. The diagram above is the timing chart of SF-CEX(-0) in normal operation. In normal operation, auxiliary output (override output) is maintained in the ON state. In normal operation, auxiliary output (muting lamp output) is maintained in the ON state. Light

11 7 Exclusive Control Unit for Light Curtain SERIES PRECAUTIONS FOR PROPER Refer to p.9 for general precautions. Light Time chart [SF-CEX(-0)] Test input, Override input The diagram shows operation with safety outputs and in auto-reset mode. Open Test input Short-circuited Override input Valid Invalid Light received light curtain Light interrupted Muting sensor ON / output ON (, ) output ON (, ) Auxiliary output ON (Muting output) Auxiliary output ON (Override output) Muting lamp ON output / Light received light curtain Light interrupted Muting ON sensor Muting ON sensor output ON (, ) Auxiliary output ON (Muting output) Auxiliary output ON (Blown lamp output) Muting lamp ON output Muting lamp output ON 0 to sec. sec. Blown lamp Override input time: Max. 0 sec. outputs and are during test input. The override function becomes valid when all the conditions listed below are satisfied: An incandescent lamp with. to 0 W is at least connected to either muting lamp output or. The signal is input to either muting sensor or. The override input terminal O and O is short-circuited and the test input terminal T / T is opened within sec. ( sec. continuously) If one of the three conditions above becomes invalid or the timing exceeds 0 sec., the override function becomes invalid. Blown lamp output The diagram shows operation with safety outputs and in auto-reset mode. Blown lamp Blown lamp The lamps are monitored during muting state, and if either of them breaks, auxiliary output is turned. If only one lamp breaks, the muting state is maintained, however, if both lamps break, the muting state is canceled immediately. Others This device has been developed / produced for industrial use only. When connecting this product to a product other than the connectable input device, the system does not conform to the control category based on ISO 89- (EN ISO 89-, JIS B 970-). The power supply unit of series uses the electronic fuse which does not require any replacement. When the electronic fuse trips, turn off the power supply and eliminate the cause for the overcurrent. After that, turn the power back on. The electronic fuse is not meant to be used for equipment that is operated continuously. Note that the specification may not be satisfied by continuous operation. Make sure to carry out the wiring in the power supply off condition. Wrong wiring will damage the product. Verify that the supply voltage variation is within the rating. Note that if a voltage exceeding the rated range is applied, or if an AC power supply is directly connected, the unit may get burnt or damaged. The DC power supply unit must satisfy the conditions given below: ) Power supply unit authorized in the region where this device is to be used. ) Power supply unit conforming to EMC Directive and Lowvoltage Directive (In case CE conformity is required.) ) Power supply unit conforming to the Low-voltage Directive and with an output of 0A or less. ) The frame ground (F.G.) terminal must be connected to ground when using a commercially available switching regulator. ) Power supply unit with an output holding time of 0 ms or more. ) Use an isolation transformer for the DC power supply unit. 7) If surges are likely to occur, take countermeasures such as connecting a surge absorber to the origin of the surge. 8) Power supply unit corresponding to CLASS (In case UL/c-UL conformity is required.) <Additional information> As provided in IEC 0 (CLASS: Protection against Electric Shook), this power supply should require no ground earth and satisfy the insulation distance by double insulation or reinforced insulation. If the power supply conforms to Low-voltage Directive and has an output of 0A or less, it can be used as a suitable product. Do not run the wires together with high-voltage lines or power lines or put them in the same raceway. This can cause malfunction due to induction. This product is not dust-proof / splash proof. Be sure to put this product into a control box having IP construction. (Excluding SF-C) Avoid dust, dirt and steam. Take care that the product does not come in direct contact with oil, grease, or organic solvents, such as, thinner, etc. Note that this equipment is applicable only in the control circuit grounded in accordance with IEC 00- and JIS B 990-, or in the control circuit in which the insulation monitor unit (ground fault detection unit) is included. This unit is suitable for indoor use only. The seal as shown in the drawing on the below is stuck to the engagement point of unit. If the seal is peeled off or broken, series will not be certified as equipment and will not be covered by our guarantee. Do not open! If this seal is removed or damaged, the units are not recognized as safety product.

12 Exclusive Control Unit for Light Curtain SERIES 7 DIMENSIONS (Unit: mm in) The CAD data can be downloaded from our website. SF-C Control unit SF-C Control unit (.97 ) Suitable for mm.78 in width DIN rail 0. = 8 0. = Receiver side -ø ø0. -ø0 ø ( ) SF-C Control unit SF-CEX(-0) Application expansion unit Suitable for mm.78 in width DIN rail = 0.97 = (.898) Suitable for mm.78 in width DIN rail Receiver side.. 0. Light

SF-C10 SERIES. Exclusive Control Unit for Light Curtain. Plug-in type control unit. Robust type control unit SF-C12 Slim type control unit SF-C13

SF-C10 SERIES. Exclusive Control Unit for Light Curtain. Plug-in type control unit. Robust type control unit SF-C12 Slim type control unit SF-C13 Exclusive Unit for Curtain SERIES PHOTO PHOTO MEASURE Conforming to Machine, Low Voltage (SF-C/C only) & EMC Directive Certified Listing Less setup time for safety circuits Plug-in type control unit SF-C

More information

Monitor. Safety relay,etc. Contactor, etc. Uses external device monitoring function Note: Construct a separate reset input circuit.

Monitor. Safety relay,etc. Contactor, etc. Uses external device monitoring function Note: Construct a separate reset input circuit. Selectable safety circuits The light curtain unit has a built-in monitoring function for external devices (such as fused relay monitoring). This supports the construction of light curtain peripheral safety

More information

Remote I/O Unit with Connectors for Light Curtain CC-Link Safety System. panasonic.net/id/pidsx/global

Remote I/O Unit with Connectors for Light Curtain CC-Link Safety System. panasonic.net/id/pidsx/global 715 LIGHT CURTAINS / USE Remote I/O Unit with Connectors for Light Curtain CC-Link System General terms and conditions... F-7 Related Information... P.703~ SF4B... P.565~ General precautions... P.1501

More information

panasonic.net/id/pidsx/global The control category differs depending on the configuration and wiring of the external circuit.

panasonic.net/id/pidsx/global The control category differs depending on the configuration and wiring of the external circuit. 675 Compact Beam Sensor Type 4 SERIES Related Information General terms and conditions... F-3 General precautions... P.1595 PHOTO PHOTO Certified Listing Conforming to OSHA / ANSI MEASURE Category 4 PLe

More information

panasonic.net/id/pidsx/global The control category differs depending on the configuration and wiring of the external circuit.

panasonic.net/id/pidsx/global The control category differs depending on the configuration and wiring of the external circuit. 545 Compact Curtain Type 4 SERIES Related Information General terms and conditions... F-3 SF-C13... P.663~ General precautions... P.1595 guide... P.457~ Glossary of terms... P.1549~ Korea s S-mark... P.1602

More information

panasonic.net/id/pidsx/global The control category differs depending on the configuration and wiring of the external circuit.

panasonic.net/id/pidsx/global The control category differs depending on the configuration and wiring of the external circuit. 631 Ultra-slim Light Curtain Type 2 SERIES Related Information General terms and conditions... -3 Glossary of terms / General precautions...p.1549~ / P.1595 guide...p.457~ S-C13... P.663~ PHOTO PHOTO Certified

More information

panasonic.net/id/pidsx/global CCD The sensor can be used for various applications with its binary data output with four different sensing modes.

panasonic.net/id/pidsx/global CCD The sensor can be used for various applications with its binary data output with four different sensing modes. 1123 PHOTO PHOTO PARTICUR Type Edge Sensor SERIES Related Information General terms and conditions... F-3 About laser beam... P.1593~ guide... P.1021~ General precautions... P.1595 Conforming to FDA regulations

More information

Optimum sensing capability for LCD manufacturing

Optimum sensing capability for LCD manufacturing SENSORS FOR Glass Substrate Detection Sensor Amplifier-separated FX-301-F FT-F9 FD-F7 EX-F70/F60 HD-T1 M FD-L3 Reliable detection of glass substrates Its unique optical system enables detection of transparent

More information

Both Compact and Robust. Safety Light Curtain SF4D SERIES. New Concept. GB Conforming to Compact & Robust panasonic.net/id/pidsx/global

Both Compact and Robust. Safety Light Curtain SF4D SERIES. New Concept. GB Conforming to Compact & Robust panasonic.net/id/pidsx/global Compact & Robust Type4 PLe SIL3 Safety Light Curtain SF4D SERIES Conforming to OSHA / ANSI Certified GB Conforming to 4584 NRTL certified Certified (Excluding SF4D- -01) New Concept Both Compact and Robust

More information

Type 4. Depth

Type 4. Depth 499 Compact Curtain Type 4 SERIES Related Information General terms and conditions... F-7 SF-C10... P.703~ General precautions... P.1458~ Sensor selection guide... P.497~ Glossary of terms... P.1455~ Korea

More information

EF-S1 SERIES. Continuously check invisible static electricity in lines. Constantly check static in lines!

EF-S1 SERIES. Continuously check invisible static electricity in lines. Constantly check static in lines! 1215 PHOTO PHOTO SAFETY USE SERIES Related Information General terms and conditions... F- General precautions... P.1595 guide... P.1155~ MEASUREMENT panasonic.net/id/pidsx/global Continuously check invisible

More information

One step ahead in performance and mounting ease

One step ahead in performance and mounting ease 95 Micro Photoelectric Amplifier Built-in PM-5 SERIES PM-45 SERIES PM-5 SERIES General terms and conditions... F- guide... P.9~ Related Information Glossary of terms / General precautions...p.1549~ / P.155~

More information

NA1-5. Ultra-slim Body 25mm Beam Pitch Area Sensor. Even a Slim Hand Is Detected by the 25mm Pitch Beam Curtain AREA SENSORS.

NA1-5. Ultra-slim Body 25mm Beam Pitch Area Sensor. Even a Slim Hand Is Detected by the 25mm Pitch Beam Curtain AREA SENSORS. Ultra-slim Body 2mm Pitch Area Sensor mm Thick: /2 of Conventional Model It fits into a small space, without obstructing normal operation. Clearly Visible Job Indicator Both the emitter and the receiver

More information

G9SX-GS. Safety Guard Switching Unit. A Safety Measure for Hazardous Operations That Does Not Lower Productivity. Auto Switching Function

G9SX-GS. Safety Guard Switching Unit. A Safety Measure for Hazardous Operations That Does Not Lower Productivity. Auto Switching Function Safety Guard Switching Unit CSM DS_E_6_1 A Safety Measure for Hazardous Operations That Does Not Lower Productivity Two functions support two types of application: Auto switching: For applications where

More information

SALES NUMBER NUMBER OF BEAMS PROTECTIVE HEIGHT

SALES NUMBER NUMBER OF BEAMS PROTECTIVE HEIGHT SECTION 21 182 Safety Light Curtains Type: SLC-F Finger (14mm) FEATURES: Resolution: 14mm Protective height: 160mm to 1040mm Type 4 according to IEC61496-1 and -2 ORDERING INFORMATION: SALES OF BEAMS PROTECTIVE

More information

Safety Control. FS1A Multi-function Safety Relay. Optional Parts. Marked Cable Tie. DIN Rail BNDN1000 Aluminum, 1m 35mm wide

Safety Control. FS1A Multi-function Safety Relay. Optional Parts. Marked Cable Tie. DIN Rail BNDN1000 Aluminum, 1m 35mm wide Control Multi-function Relay Key features: No programming required. Configuration complete by turning on a logic switch A safety circuit can be configured easily just by selecting a logic from eight preprogrammed

More information

GL SERIES. Compact & Low Price Inductive Proximity Sensor. Wide variety, high performance in surprisingly small body at low cost.

GL SERIES. Compact & Low Price Inductive Proximity Sensor. Wide variety, high performance in surprisingly small body at low cost. 811 Compact & ow Price Inductive Proximity Sensor SERIES Related Information General terms and conditions... F-3 Glossary of terms...p.176~ guide... P.781~ General precautions... P.179~ PHOTO PHOTO MEASURE

More information

Making Hazardous Operations Safe and Productive

Making Hazardous Operations Safe and Productive NEW Safety Guard Switching Unit G9SX-GS Making Hazardous Operations Safe and Productive Making Hazardous Operations Safe and Productive This new addition to the model of Flexible Safety Unit G9SX series

More information

Safety Control. FS1A Multi-function Safety Relay. Optional Parts. Connecting Tool. Marked Cable Tie. DIN Rail BNDN1000 Aluminum, 1m 35mm wide

Safety Control. FS1A Multi-function Safety Relay. Optional Parts. Connecting Tool. Marked Cable Tie. DIN Rail BNDN1000 Aluminum, 1m 35mm wide Multi-function Relay Key features: No programming required. Configuration complete by turning on a logic switch A safety circuit can be configured easily just by selecting a logic from eight preprogrammed

More information

Suitable for detecting transparent films or transparent bottles

Suitable for detecting transparent films or transparent bottles Ultrasonic Sensor Suitable for detecting transparent films or transparent bottles Reliable detection of transparent objects The sensor reliably detects transparent films or transparent objects. Only 16

More information

PM-24 SERIES. Ultra-small U-shaped Micro Photoelectric Sensor. Extremely small size enables space saving!! ( ) Equipped with two independent outputs

PM-24 SERIES. Ultra-small U-shaped Micro Photoelectric Sensor. Extremely small size enables space saving!! ( ) Equipped with two independent outputs 19 Ultra-small Micro Photoelectric Sensor PM- SERIES Related Information General terms and conditions...p.1 Glossary of terms / General precautions...p.98~ / P.98~ Amplifier Built-in Sensor selection guide...p.11~

More information

SERIES. FX-311 realizes the ultimate in ease-of-operation. Its operation enables easy and full use of latest technology.

SERIES. FX-311 realizes the ultimate in ease-of-operation. Its operation enables easy and full use of latest technology. FX-11 SERIES FX-11 realizes the ultimate in ease-of-operation. Its operation enables easy and full use of latest technology. Presenting a product which satisfies professionals using volume control. Besides

More information

EX-30SERIES. Threaded Miniature Photoelectric Sensor. The next-generation New Form series. A new alternative to fiber sensors. M4(Reflective type: M6)

EX-30SERIES. Threaded Miniature Photoelectric Sensor. The next-generation New Form series. A new alternative to fiber sensors. M4(Reflective type: M6) EX-3SERIES Threaded Miniature Photoelectric The next-generation New Form series. A new alternative to fiber sensors. Marked Conforming to EMC Directive The EX-3 series have a radically new form which has

More information

Main contacts Auxiliary contact Number of input channels Rated voltage Model Category 24 VAC/VDC 3PST-NO SPST-NC 1 channel or 2 channels possible

Main contacts Auxiliary contact Number of input channels Rated voltage Model Category 24 VAC/VDC 3PST-NO SPST-NC 1 channel or 2 channels possible Safety Relay Unit Four kinds of -mm wide Units are available: A -safety contact model, a -safety contact model, and models with safety contacts and OFF-delay safety contacts. Also available are 7.-mm wide

More information

panasonic.net/id/pidsx/global Machine safeguarding without sacrificing productivity

panasonic.net/id/pidsx/global Machine safeguarding without sacrificing productivity 531 Ultraslim Curtain Type 4 SERIES Related Information General terms and conditions... F7 SFC10... P.703~ General precautions... P.1458~ Sensor selection guide... P.497~ Glossary of terms... P.1455~ Korea

More information

Ultra-slim Light Curtain

Ultra-slim Light Curtain Ultraslim Type 4 PLe SIL3 LIGHT CURTAIN SF4CSERIES Conforming to Machine & EMC Directive Certified Conforming to OSHA / ANSI Certified by NRTL JIS Machine safeguarding without sacrificing productivity

More information

Cylindrical Compact Inductive Proximity Sensor Amplifier Built-in. panasonic.net/id/pidsx/global

Cylindrical Compact Inductive Proximity Sensor Amplifier Built-in. panasonic.net/id/pidsx/global 8 PHOTO PHOTO MEASURE Cylindrical Compact Inductive Proximity SERIES Related Information General terms and conditions... F- Glossary of terms... P.576~ panasonic.net/id/pidsx/global guide... P.78~ General

More information

Plug-in unit extension block One sensor extension block allows four plug-in units to be added. Power cable for sensors. Snap-connector inputs

Plug-in unit extension block One sensor extension block allows four plug-in units to be added. Power cable for sensors. Snap-connector inputs 1 Sensor Block for SC Quick connection of 16 sensors Set of 16 inputs directly hooked up to PLC Up to 16 sensors can be connected on one main block followed by three extension blocks (or one snapconnector

More information

Ultra-small U-shaped Micro Photoelectric Sensor. Extremely small size enables space saving!! 12 mm in

Ultra-small U-shaped Micro Photoelectric Sensor. Extremely small size enables space saving!! 12 mm in 1 Ultra-small Micro Photoelectric PM- SERIES Related Information General terms and conditions... F-17 Glossary of terms / General precautions... P.19~ / P.10 Amplifier Built-in selection guide... P.1~

More information

DC 3-wire Cylindrical Inductive Proximity Sensor. Long sensing range

DC 3-wire Cylindrical Inductive Proximity Sensor. Long sensing range INDUCTIVE SERIES DC 3-wire Cylindrical Inductive Proximity Oil resistant Metal embedding possible Amplifier Built-in GX G-6 High performance and environmental resistance at low price G-8/8U GA-/GH GX GX-U/FU

More information

Connector Built-in U-shaped Micro Photoelectric Sensor. Approximately 60 % of previous model Detachable

Connector Built-in U-shaped Micro Photoelectric Sensor. Approximately 60 % of previous model Detachable 44 Connector Built-in Micro Photoelectric SERIES Related Information General terms and conditions... F-1 Glossary of terms... P.1~ selection guide... P.441~ General precautions... P.140 Amplifier Built-in

More information

DPST-NO None 2 channels Auto-reset Inverse (+/-) 24 VAC/VDC 4 G9SB-2002-A 1 channel or 2

DPST-NO None 2 channels Auto-reset Inverse (+/-) 24 VAC/VDC 4 G9SB-2002-A 1 channel or 2 Safety Relay Unit Ultra Slim Safety Relay Unit 17.5 mm wide models available with 2 or 3 poles. 22.5 mm wide 3 pole models also available EN Standards (TÜV approval) DIN-track mounting possible Ordering

More information

GX SERIES. Cylindrical Compact Inductive Proximity Sensor Amplifier Built-in. Robust enclosure and flexible cable types are also available

GX SERIES. Cylindrical Compact Inductive Proximity Sensor Amplifier Built-in. Robust enclosure and flexible cable types are also available 8 Cylindrical Compact Inductive Proximity SERIES Related Information General terms and conditions... F-7 Glossary of terms... P.86~ selection guide... P.757~ General precautions... P.05 PHOTO PHOTO Conforming

More information

PM2 SERIES. Convergent Reflective Micro Photoelectric Sensor. Convergent reflection sensing ensures stable detection

PM2 SERIES. Convergent Reflective Micro Photoelectric Sensor. Convergent reflection sensing ensures stable detection PHOTO PHOTO Micro Photoelectric PM SERIES Related Information General terms and conditions... F-3 Glossary of terms... P.9~ Amplifier Built-in guide... P.393~ General precautions... P.~ Certified MEASURE

More information

panasonic.net/id/pidsx/global The control category differs depending on the configuration and wiring of the external circuit.

panasonic.net/id/pidsx/global The control category differs depending on the configuration and wiring of the external circuit. 577 Ultraslim Light Curtain Type 4 SERIES Related Information General terms and conditions... F3 SFC13... P.663~ General precautions... P.1595 guide... P.457~ Glossary of terms... P.1549~ Korea s Smark...

More information

PM2 SERIES. Convergent Reflective Micro Photoelectric Sensor. Convergent reflection sensing ensures stable detection

PM2 SERIES. Convergent Reflective Micro Photoelectric Sensor. Convergent reflection sensing ensures stable detection 3 Micro Photoelectric PM SERIES Related Information General terms and conditions... F-3 Glossary of terms... P.~ Amplifier Built-in selection guide... P.7~ General precautions... P.8~ PHOTO PHOTO Conforming

More information

Expansion Unit G9SX-EX Safety 2 Instantaneous safety outputs

Expansion Unit G9SX-EX Safety 2 Instantaneous safety outputs Flexible Safety Unit / Safety Guard Switching Unit G9SX/G9SX-GS CSM_G9SX_G9SX-GS_DS_E_8_1 Logical Function Adds Flexibility to Various Safety Circuits Be sure to read the Safety Precautions on page 45.

More information

GA-311 GH SERIES. Compact Inductive Proximity Sensor Amplifier-separated. High-speed response and excellent workability

GA-311 GH SERIES. Compact Inductive Proximity Sensor Amplifier-separated. High-speed response and excellent workability 82 PHOTO PHOTO Compact Inductive Proximity Sensor -separated GA- SERIES General terms and conditions... F-7 Related Information Glossary of terms... P.86~ Sensor selection guide... P.757~ General precautions...

More information

PM2 SERIES. Convergent Reflective Micro Photoelectric Sensor. Convergent reflection sensing ensures stable detection

PM2 SERIES. Convergent Reflective Micro Photoelectric Sensor. Convergent reflection sensing ensures stable detection 3 Micro Photoelectric PM SERIES Related Information General terms and conditions...p. Glossary of terms...p.983~ selection guide...p.~ / P.9~ General precautions...p.98~ Amplifier Built-in PHOTO PHOTO

More information

Compact Inductive Proximity Sensor

Compact Inductive Proximity Sensor SERIES Compact Inductive Proximity Sensor Amplifier Built-in High functionality together with robust housing and flexible cable Miniature is an amplifier built-in inductive proximity sensor having a diameter

More information

Number of input channels

Number of input channels Safety Relay Unit (Sensor Connector Type) CSM DS_E_3_1 Less Wiring Required with Safety Light Curtain Sensor connector allows direct connection to OMRON 3SJ Safety Light Curtains with PNP outputs. Reduces

More information

GA-311 GH SERIES. Compact Inductive Proximity Sensor Amplifier-separated. High-speed response and excellent workability. IP67G sensor head variations

GA-311 GH SERIES. Compact Inductive Proximity Sensor Amplifier-separated. High-speed response and excellent workability. IP67G sensor head variations 875 PHOTO PHOTO IT FOW PARTICUAR Compact Inductive Proximity Sensor -separated GA- SERIES General terms and conditions... F-7 Related Information Glossary of terms... P.482~ Sensor selection guide... P.80~

More information

The World s in Compactness. * Among photoelectric sensors with built-in amplifier, as of June 2015 (survey by our company)

The World s in Compactness. * Among photoelectric sensors with built-in amplifier, as of June 2015 (survey by our company) Amplifier Built-in Ultra-minute Photoelectric Sensor EX-Z SERIES Conforming to EMC Directive Recognition No. 1 The World s in Compactness * Among photoelectric sensors with built-in amplifier, as of June

More information

DC 3-wire Cylindrical Inductive Proximity Sensor. Long sensing range

DC 3-wire Cylindrical Inductive Proximity Sensor. Long sensing range INDUCTIVE SERIES DC 3-wire Cylindrical Inductive Proximity Oil resistant Metal embedding possible Amplifier Built-in GX G-6 High performance and environmental resistance at low price GA-/GH GX GX-U/FU

More information

No. 1. The World s in Compactness. Amplifier Built-in Ultra-minute Photoelectric Sensor EX-Z SERIES panasonic.net/id/pidsx/global

No. 1. The World s in Compactness. Amplifier Built-in Ultra-minute Photoelectric Sensor EX-Z SERIES panasonic.net/id/pidsx/global Ultra-minute Photoelectric Sensor EX-Z SERIES Conforming to EMC Directive No. 1 The World s in Compactness * Among photoelectric sensors with built-in amplifier, as of June 215 (survey by our company)

More information

G9SA. Ordering Information. Safety Relay Unit. The G9SA Series Offers a Complete Line of Compact Units. H Several types of 45-mm wide Units are

G9SA. Ordering Information. Safety Relay Unit. The G9SA Series Offers a Complete Line of Compact Units. H Several types of 45-mm wide Units are Safety Relay Unit The G9SA Series Offers a Complete Line of Compact Units H Several types of -mm wide Units are available: a -pole model, a -pole model, models with poles and OFF-delay poles H 7.-mm wide

More information

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m.

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m. Built-in Amplifier (Medium Size) ES-A Be sure to read Safety Precautions on page 0. Ordering Information Built-in Amplifier s Red light Infrared light Sensing method Appearance Connection method Sensing

More information

DC 2-wire Cylindrical Inductive Proximity Sensor

DC 2-wire Cylindrical Inductive Proximity Sensor SERIES DC -wire Cylindrical Inductive Proximity -wire type available Oil resistant Metal embedding possible Amplifier Built-in GX G-6 High performance & ease of use G-8/8U GA-/GH GX GX-N G-8H/8H G-N Robust

More information

Inductive Proximity Sensor

Inductive Proximity Sensor Inductive Proximity Sensor Miniature, Slim-styled Proximity Sensor Space-saving Sensor ideal for timing cam and dog detection. Four mounting holes provided: two each mounting from side or rear of the housing.

More information

Thread length (overall length) material

Thread length (overall length) material Cylindrical Proximity Sensor for Mobile Usage Designed and tested to keep your machines moving IP69k tested and certified for highest water resistance e1 type approval (according to automotive directive

More information

Convergent Reflective Micro Photoelectric Sensor

Convergent Reflective Micro Photoelectric Sensor EQ- VF NX PM MS-AJ RT- PX- CY PHOTOELECTRIC SENSORS Mounting Stand Amplifier Built-in SERIES Convergent Reflective Micro Photoelectric Stable detection by convergent reflective mode Stable detection characteristics

More information

Safety Monitoring Relays

Safety Monitoring Relays Safety Monitoring Relays Contents Selection Guide I-2 Safety Monitoring Relays G9SA I-6 SR101A I-12 SR103AM I-13 SR104P I-17 SR105E I-17 SR106ED I-21 SR108AD & SR109AD I-18 SR120MP I-21 SR125SMS45 I-22

More information

Adjustable Range Reflective Photoelectric Sensor Amplifier Built-in

Adjustable Range Reflective Photoelectric Sensor Amplifier Built-in 36 FIBER PHOTO MICRO PHOTO AREA LIGHT CURTAINS PRESSURE / FLOW INUCTIVE PROXIMITY PARTICULAR USE SENSOR SIMPLE UNITS MEASUREMENT STATIC CONTROL EVICES ENOSCOPE MARKERS Adjustable Range Reflective Photoelectric

More information

BNS SERIES - COMPATIBLE SERIES AES SAFETY CONTROLLERS SELECTION CHART AVAILABLE STANDARD MODELS

BNS SERIES - COMPATIBLE SERIES AES SAFETY CONTROLLERS SELECTION CHART AVAILABLE STANDARD MODELS BNS SERIES - COMPATIBLE SERIES AES SAFETY CONTROLLERS SELECTION CHART AVAILABLE STANDARD MODELS Safety Controller Suitable for use with Coded-Magnet Sensor Part Numbers below BNS250... BNS33... BNS303...

More information

Safety Monitoring Relays

Safety Monitoring Relays Safety Monitoring Relays G9SA G9SA Safety Relay Unit Four kinds of 45-mm wide units are available: A 3-pole model, a 5-pole model, and models with 3 poles and 2 OFF-delay poles, as well as a two-hand controller.

More information

The dual display means that the current value and the threshold value, it makes direct setting of threshold value

The dual display means that the current value and the threshold value, it makes direct setting of threshold value 735 Dual Display Digital Pressure Sensor DPC-L100 SERIES SERIES General terms and conditions... F-3 guide... P.699~ Related Information Glossary of terms... P.1563~ General precautions... P.1566 For Liquid

More information

Ultra-slim Body Picking Sensor NA1-PK5 SERIES NA1-5 SERIES. Even a slim hand is detectable by the 25 mm in pitch beam area sensor

Ultra-slim Body Picking Sensor NA1-PK5 SERIES NA1-5 SERIES. Even a slim hand is detectable by the 25 mm in pitch beam area sensor 487 FIBER PHOTO MICRO PHOTO AREA IGHT CURTAINS PRESSURE / FOW INDUCTIVE PROXIMITY PARTICUAR USE SENSOR SIMPE UNITS MEASUREMENT STATIC CONTRO DEVICES ENDOSCOPE MARKERS Ultra-slim Body Picking Sensor NA-PK5

More information

G9SX-LM. Low-speed Monitoring Unit. Low-speed Monitoring Function Ensures Safety for Maintenance Work. Model Number Structure.

G9SX-LM. Low-speed Monitoring Unit. Low-speed Monitoring Function Ensures Safety for Maintenance Work. Model Number Structure. Low-speed Monitoring Unit G9SX-LM Low-speed Monitoring Function Ensures Safety for Maintenance Work Motor rotation speed detected by Proximity Sensor. Monitors and confirms that speed does not exceed the

More information

Mini Photoelectric Sensor

Mini Photoelectric Sensor Mini Photoelectric Sensor High cost-performance Mini Photoelectric Sensor Saves Installation Space and Wiring Effort and Detects Minute Sensing Objects Pin-point beam (1 to 2-mm dia.) makes it possible

More information

Model Number Structure

Model Number Structure Solid State Relays with Failure Detection Function G3PC CSM_G3PC_DS_E_1_1 Refer to Safety Precautions for All Solid State Relays. Detects failures in SSR used for heater temperature control and simultaneously

More information

High-speed sampling and high resolution. The new choice for even more variegated data collection and processing.

High-speed sampling and high resolution. The new choice for even more variegated data collection and processing. 1105 PHOTO PHOTO High Speed High Accuracy Eddy Current Type Digital Sensor SERIES Related Information General terms and conditions... F-7 Glossary of terms... P.1493 Sensor selection guide... P.1055~ General

More information

E3FS. Connect up to 4 sets of E3ZS/E3FS per B1 Module for F3SX Safety Controller

E3FS. Connect up to 4 sets of E3ZS/E3FS per B1 Module for F3SX Safety Controller Single-beam Safety Sensor Type 2 Safety Photoelectric Sensor for Hazardous Gaps in Machines Note: Be sure to read the Safety Precautions International standards: IEC6496- (type 2 ESPE) IEC6496-2 (type

More information

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m.

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m. Built-in Amplifier (Medium Size) ES-A CSM_ES-A_DS_E Be sure to read Safety Precautions on page 0. Ordering Information Built-in Amplifier s Red light Infrared light Sensing method Appearance Connection

More information

High-speed sampling and high resolution. The new choice for even more variegated data collection and processing.

High-speed sampling and high resolution. The new choice for even more variegated data collection and processing. 1105 High Speed High Accuracy Eddy Current Type Digital Sensor SERIES Related Information General terms and conditions... F-7 Glossary of terms... P.1493 Sensor selection guide... P.1055~ General precautions...

More information

GX-5SU(B) is just 5.4 mm 0.213in in diameter, the smallest in existing DC two-wire sensors. It saves you space.

GX-5SU(B) is just 5.4 mm 0.213in in diameter, the smallest in existing DC two-wire sensors. It saves you space. DC 2-wire Cylindrical Inductive Proximity SERIES Amplifier Built-in High performance & ease of use Robust in tightening The tightening torque has been improved to approx. four times greater than that of

More information

Tecnología en Electrónica y Control SRL Ficha Técnica

Tecnología en Electrónica y Control SRL Ficha Técnica Tecnología en Electrónica y Control SRL Ficha Técnica Relé de seguridad Tecnología en Electrónica y Control SRL Oficina Central Wüthrich 949 San Carlos Centro (S3013DES) / Santa Fe / Argentina Tel./Fax/Líneas

More information

G9SA. Safety Relay Unit. The G9SA Series Offers a Complete Line-up of Compact Units. Model Number Structure

G9SA. Safety Relay Unit. The G9SA Series Offers a Complete Line-up of Compact Units. Model Number Structure Safety Relay Unit G9 CSM_G9_DS_E The G9 Series Offers a Complete Line-up of Compact Units. Four kinds of -mm wide Units are available: A -pole model, a -pole model, and models with poles and OFF-delay

More information

Installation Sensing distance Connection Output configuration Operation mode NO Operation mode NC

Installation Sensing distance Connection Output configuration Operation mode NO Operation mode NC Standard (thin shape) Inductive Proximity Sensor Thin shape for space saving surface mounting Direct side wall mounting for bracket-less installation Ordering Information DC 3-wire Models Installation

More information

PM2 SERIES. Convergent Reflective Micro Photoelectric Sensor. Convergent reflection sensing ensures stable detection. Hardly affected by background

PM2 SERIES. Convergent Reflective Micro Photoelectric Sensor. Convergent reflection sensing ensures stable detection. Hardly affected by background PHOTO PHOTO USE MEASUREMENT STATIC CONTROL Micro Photoelectric SERIES Related Information General terms and conditions... F- Glossary of terms... P.39~ selection guide... P.~ General precautions... P.0

More information

Inductive Proximity Sensor

Inductive Proximity Sensor Inductive Proximity Sensor Subminiature Sensor with Cable Amplifier Offers Greater Mounting Flexibility Programmable Controller-compatible Subminiature, shielded sensing head (3 or 8 dia.) allows the Sensor

More information

E2Q4 Square Proximity Sensor

E2Q4 Square Proximity Sensor Inductive Square Slim, compact size M2 Plug-in connection Integrated short circuit and reverse polarity protection Active face positioning: Y-axis 5, X-axis 90 incremets Ordering Information DC type Connection

More information

Head-separated Dual Display Digital Pressure Sensor DPC-L100 SERIES DPH-L100 SERIES. High-precision detection of fluid and air pressure

Head-separated Dual Display Digital Pressure Sensor DPC-L100 SERIES DPH-L100 SERIES. High-precision detection of fluid and air pressure 689 PHOTO PHOTO Dual Display Digital Pressure Sensor DPC-L100 SERIES SERIES General terms and conditions... F-17 Sensor selection guide... P.661~ Related Information Glossary of terms... P.1373~ General

More information

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions HITACHI EH-150 series PLC Resistance Temperature Detective input module Instruction manual Thank you for purchasing a Hitachi Programmable Logic Controller. To operate it safely, please read this instruction

More information

U-shaped Type/Convergent Reflective Type. onlinecomponents.com

U-shaped Type/Convergent Reflective Type. onlinecomponents.com PHOTOELECTRIC SENSOR SERIES U-shaped Type/Convergent Reflective Type SS-A SU-7/SH VF NX MS-AJ RT- PX- EX CY Amplifier-separated Type Multi-voltage Type Amplifier Built-in Type Mounting Stand Stable Detection

More information

Precise sensing in wide area. Sensing area: mm in Minimum sensing object: "0.1 mm "0.004 in Repeatability: 10!m 0.

Precise sensing in wide area. Sensing area: mm in Minimum sensing object: 0.1 mm 0.004 in Repeatability: 10!m 0. MEASUREMENT SENSORS SERIES Laser Collimated Beam Sensor -300 HL-T1 LM LH-0 HL-C1 Safe laser beam This laser collimated beam sensor conforms to the Class 1 laser stipulated in IEC Publication 82 and JIS

More information

From ultra-thin lead frames to iron sheets... Double feed detection of various metal sheets

From ultra-thin lead frames to iron sheets... Double feed detection of various metal sheets 1135 Detector SERIES Related Information General terms and conditions... F-3 General precautions...p.1595 PHOTO PHOTO MEASURE From ultra-thin lead frames to iron sheets... Double feed detection of various

More information

NPN output PNP output Cord connection Cord length: 2 m Through-beam 7 m Light-ON. 2 m. (selectable by wiring) Diffuse reflective 0.

NPN output PNP output Cord connection Cord length: 2 m Through-beam 7 m Light-ON. 2 m. (selectable by wiring) Diffuse reflective 0. Built-in Amplifier Photoelectric Sensor E3V3 Easy-to-use, Low-cost Photoelectric Sensor Incorporating s that can be clearly seen from a distance. A series of models with an M8 metal junction connector

More information

High-speed sampling and high resolution. The new choice for even more variegated data collection and processing.

High-speed sampling and high resolution. The new choice for even more variegated data collection and processing. 867 PHOTO PHOTO High Speed High Accuracy Eddy Current Type Digital Sensor SERIES Related Information General terms and conditions... P.1 Glossary of terms... P.1019 Sensor selection guide... P.11~ / P.833~

More information

From ultra-thin lead frames to iron sheets... Double feed detection of various metal sheets

From ultra-thin lead frames to iron sheets... Double feed detection of various metal sheets 1147 Detector SERIES Related Information General terms and conditions... F-7 General precautions...p.151 PHOTO PHOTO MEASURE ITY From ultra-thin lead frames to iron sheets... Double feed detection of various

More information

Thread length. 27 (40) mm. 27 (44) mm. 27 (40) mm. 34 (50) mm. 34 (49) mm. 39 (60) mm. 39 (54) mm. 44 (65) mm. 44 (59) mm

Thread length. 27 (40) mm. 27 (44) mm. 27 (40) mm. 34 (50) mm. 34 (49) mm. 39 (60) mm. 39 (54) mm. 44 (65) mm. 44 (59) mm Long Distance Cylindrical. Extra long for increased protection and sensing performance triple proximity sensors for flush mounting requirements. designed and tested for extra long life. Ordering Information

More information

SEN TRONIC AG WARNING. QUICK INSTRUCTION MANUAL Compact Light Curtain / Type 4 SF4B- C 1 SAFETY PRECAUTIONS 2 CONFIRMATION OF PACKED CONTENTS

SEN TRONIC AG WARNING. QUICK INSTRUCTION MANUAL Compact Light Curtain / Type 4 SF4B- C 1 SAFETY PRECAUTIONS 2 CONFIRMATION OF PACKED CONTENTS QUICK INSTRUCTION MANUAL Compact Light Curtain / Type 4 SF4B- C ME-SF4BC No.0053-27V Thank you very much for purchasing Panasonic products. Read this Instruction Manual carefully and thoroughly for the

More information

High-speed sampling and high resolution. The new choice for even more variegated data collection and processing.

High-speed sampling and high resolution. The new choice for even more variegated data collection and processing. 1023 PHOTO PHOTO High Speed High Accuracy Eddy Current Type Digital Sensor SERIES Related Information General terms and conditions... F- Glossary of terms... P.1397 Sensor selection guide... P.967~ General

More information

Long sensing range of 500 mm in (HL-T1005A, HL-T1010A) and 2 m ft (HL-T1001A) are available. Adoption of a Class 1 laser

Long sensing range of 500 mm in (HL-T1005A, HL-T1010A) and 2 m ft (HL-T1001A) are available. Adoption of a Class 1 laser MEASUREMENT SENSORS SERIES Ultra-compact Laser Collimated Beam Sensor LA LA- LM1 LH- HL-C1 The industry s smallest sensor head A high-ality intelligent controller Conforming to EMC Directive The industry

More information

E2A. Ordering Information. Cylindrical Proximity Sensor. Safe Mounting with Greater Sensing Distance. E2A Cylindrical Proximity Sensor 1

E2A. Ordering Information. Cylindrical Proximity Sensor. Safe Mounting with Greater Sensing Distance. E2A Cylindrical Proximity Sensor 1 Cylindrical Proximity Sensor E2A Safe Mounting with Greater Sensing Distance Ensures a sensing distance approximately 1. to 2 times larger than that of any conventional OMRON Sensor. Problems such as the

More information

Instruction Manual SF4B- C. Compact Light Curtain / Type 4. Phone: Fax: Web: -

Instruction Manual SF4B- C. Compact Light Curtain / Type 4. Phone: Fax: Web:  - Compact Light Curtain / Type 4 SF4B- C Instruction Manual WUME-SF4BC-7 (MEMO) 2 Panasonic Industrial Devices SUNX Co., Ltd. 2016 Thank you for purchasing Panasonic Industrial Devices SUNX s Compact Light

More information

HR1S-AC Safety Relay Modules

HR1S-AC Safety Relay Modules HRS-AC Relay Modules Transistor output provided. Removable terminal block (HRS-AC52P) allows for easy module replacement. Fault diagnosis function with dual safety circuits. Internal relay operations can

More information

Color Detection Fiber Sensor FZ-10 SERIES. Reliable and precise color discrimination. Red, green and blue LEDs. Easy set up

Color Detection Fiber Sensor FZ-10 SERIES. Reliable and precise color discrimination. Red, green and blue LEDs. Easy set up 79 Color Sensor FZ- SERIES FIBER PHOTO MICRO PHOTO AREA LIGHT CURTAINS Related Information General terms and conditions... F-17 Glossary of terms... P.1359~ Sensor selection guide...p.31~ General precautions

More information

Ultra-compact Laser Collimated Beam Sensor HL-T1 SERIES. Ultra-compact sensor head A high-functionality intelligent controller

Ultra-compact Laser Collimated Beam Sensor HL-T1 SERIES. Ultra-compact sensor head A high-functionality intelligent controller 887 Ultra-compact Beam Sensor SERIES Related Information General terms and conditions... P.1 Sensor selection guide...p.11~ / P.833~ Glossary of terms / General precautions... P.1019 / P.1027 About laser

More information

Operating instructions. Switching amplifier DN0210 DN / / 2015

Operating instructions. Switching amplifier DN0210 DN / / 2015 Operating instructions Switching amplifier DN0210 DN0220 UK 80011079 / 00 01 / 2015 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5

More information

LASER. Laser Displacement Transducer. Series LAH-G1. Key-Features:

LASER. Laser Displacement Transducer. Series LAH-G1. Key-Features: LASER Laser Displacement Transducer Series LAH-G1 Key-Features: Content: Technical Data...2 Technical Drawing...3 Electrical Connection...4 Order Code...5 ranges up to 300 mm Resolution up to 0.5 μm Protection

More information

Low Price Rectangular-shaped Inductive Proximity Sensor. The GL-N12 series is recommended to large volume users for cost reduction.

Low Price Rectangular-shaped Inductive Proximity Sensor. The GL-N12 series is recommended to large volume users for cost reduction. SERIES ow Price Rectangular-shaped Inductive Proximity PNP output Different freq. type available type available mplifier Built-in Wide variety with total cost reduction! G-10/GH GX GX-N GX-U/FU G-18H/18H

More information

Model Number Structure

Model Number Structure Solid State Relays with Failure Detection Function G3PC Detects failures in SSR used for heater temperature control and simultaneously outputs alarm signal. This SSR supports the safe design of heater

More information

Even a specular background does not affect the sensing performance if the sensor is located 30mm away from it (when directly opposite).

Even a specular background does not affect the sensing performance if the sensor is located 30mm away from it (when directly opposite). SERIES Convergent Reflective Micro Photoelectric Convergent Reflection Sensing Ensures Stable Detection Marked Conforming to EMC Directive Stable Detection by Convergent Reflective Mode Stable detection

More information

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend Solid State Relays with Failure Detection Function G3PC Refer to Warranty and Application Considerations (page 1), Safety Precautions (page 4), and Technical and Safety Information (page 6). Detects failures

More information

02/11/2015

02/11/2015 DIN Rail Mount 35 mm HSV Part number 84874320 Control of overspeed, underspeed, operating rate, stopping Measurement via discrete sensors - 3-wire PNP or NPN, Namur, voltage 0-30V or volt-free contact

More information

BGS (at min. setting) BGS (at max. setting)

BGS (at min. setting) BGS (at max. setting) Compact Photoelectric Sensor with Built-in Amplifier EZ-LS CSM_EZ-LS_DS_E_7_ Distance-settable Sensor Unaffected by Workpiece Color and Background Distance-settable triangulation model unaffected by color.

More information

GP-X SERIES Conforming to EMC Directive

GP-X SERIES Conforming to EMC Directive High Speed High Accuracy Eddy Current Type Digital Displacement Sensor GP-X SERIES Conforming to EMC Directive 25!s &.2%F.S. High-speed sampling and high resolution. The new choice for even more variegated

More information

NPN open-collector transistor (Judgment output) Current / voltage output (Linear output)

NPN open-collector transistor (Judgment output) Current / voltage output (Linear output) Ultra-compact Sensor SERIES 144 ORDER GUIDE s Type Appearance Model No. Output NPN output HL-AC1 NPN open-collector transistor (Judgment output) Current / voltage output (Linear output) PNP output HL-AC1P

More information

High Accuracy Eddy Current Type Displacement Sensor. Linearity 0.5 % F.S.

High Accuracy Eddy Current Type Displacement Sensor. Linearity 0.5 % F.S. MEASUREMENT SENSORS SERIES High Accuracy Eddy Current Type Displacement Sensor GP-X LD LA LA-300 HL-T1 LM10 LH-0 HL-C1 Accurate measurement of minute displacements Minute displacement of metallic objects

More information

Ordering Information. Smart Sensors (Inductive Displacement Type) ZX Series. Sensors

Ordering Information. Smart Sensors (Inductive Displacement Type) ZX Series. Sensors Smart Sensors (Inductive Displacement Type) ZX Series Smart Sensors that use the eddy current method are now available. Develop new applications with sub-micron sensing technology.. Ordering Information

More information