1 AIDON PRODUCT CATALOG Available Customer Products Version 4.3 A Copyright 2014 Aidon Ltd. Aidon Oy Piippukatu 11, FI JYVÄSKYLÄ, Finland

2 AIDON PRODUCT CATALOG 2 (8) Contents 1 Hardware Products Meters Series phase meters Series phase meters Series phase meters Series phase meters System Modules P2P System Modules P2MP RS System Modules P2MP MeshNET System Modules Accessories Antennas Antenna Cabling Wiring Other Spare Parts Covers and Sealing... 8

3 AIDON PRODUCT CATALOG 3 (8) 1 Hardware Products 1.1 Meters Series phase meters Aidon phase meter, 65A Aidon phase meter, 65A Integrated Circuit breaker Series phase meters Aidon phase meter, 85A Aidon phase meter, 85A Aidon phase meter, 85A Circuit Breaker, 63A Aidon phase meter, 85A Circuit Breaker, 63A

4 AIDON PRODUCT CATALOG 4 (8) Series phase meters Aidon phase meter, 100A Aidon phase meter Aidon phase meter Neutral Current Measurement Aidon phase meter Earth Fault Current Measurement Neutral Line Break Series phase meters Aidon phase meter, 100A Aidon phase CT meter Aidon phase CT meter Aidon phase meter Aidon phase meter Earth current measurement Aidon phase meter Aidon phase meter Neutral Current Measurement

5 AIDON PRODUCT CATALOG 5 (8) 1.2 System Modules P2P System Modules Aidon 5413 P2P 2G Aidon 5414 P2P 2G/3G Aidon 6410 P2P 2G Aidon 6411 P2P 2G/3G P2MP RS System Modules Aidon 5423 RS Master 2G Aidon 5424 RS Master 2G/3G Aidon 5433 RS Slave Aidon 6420 RS Master 2G Aidon 6421 RS Master 2G/3G Aidon 6430 RS Slave P2MP MeshNET System Modules Aidon 5453 MeshNET Master 2G Aidon 5454 MeshNET Master 2G/3G Aidon 5463 MeshNET Slave Aidon 6450 MeshNET Master 2G Aidon 6451 MeshNET Master 2G/3G Aidon 6460 MeshNET Slave

6 AIDON PRODUCT CATALOG 6 (8) 1.3 Accessories Antennas Aidon 5861 Internal antenna, WHIP Aidon 5864 Internal antenna, DIP90 Cable length 14.5 cm 2-sided tape for installation Aidon 5862 Directional antenna VPD90 Gain 10dBi SMA-M connector Includes a 3 m SMA-F/SMB-F adapter cable. Aidon 5865 In wall antenna, TRA900 Includes 20mm adapter ring Cable length 1.2 m Aidon 5868 External Antenna LP901 IP65 Cable length 1.5 m Aidon 5869 External Antenna LP902 IP65 Cable length 1 m For metal cabinet installations. Aidon 5873 External Antenna Quad Band IP65 Cable length 1.5 m Antenna Cabling Aidon 5847 Antenna Extension Cable Length 10 m SMB-M and s Aidon 5848 Antenna Extension Cable Length 5 m SMB-M and s Aidon 6840 Antenna Adapter Cable Length 50 cm SMB-M connector SMB-F 90-degree angle connector Aidon 5849 Antenna Extension Cable Length 3 m SMB-M and s

7 AIDON PRODUCT CATALOG 7 (8) Wiring Aidon 5855 RS485 Cable 2 x 0,5 mm2 Cable for custom length cabling 100 meter reel Aidon 5880 Wiring kit RS485, 40cm For 12 metering points For Aidon 54x3, 54x4, 64xx System Modules Aidon 5881 Wiring kit RS485, 60cm For 12 metering points For Aidon 54x3, 54x4, 64xx System Modules Aidon 5883 Wiring kit RS485, Connector For Aidon 54x3 and 54x4 system modules Aidon 5885 Wiring kit, Adapter To connect Aidon 5830 CB with Aidon 54x3 System Modules Aidon 5886 Circuit Breaker Connector Used with Aidon 5885 Aidon 6810 Wiring kit, Main switch bypass Used with a Warning Sticker Aidon Aidon 6870 External relay module 2x16A change-over relays for 6000 series meters Aidon 6871 Connector for Series 6000 meter output interface 1 x S0, load control functionalities Aidon x S0 connector For S0 output in meter or with Aidon 6870 Relay module Aidon 6875 External Voltage Connector For 6000 Series 1-phase Meters to supply AC for external devices Aidon 6876 External Voltage Connector For 6000 Series 3-phase Meters to supply AC for external devices Aidon 6880 Wiring kit RS485, Adapter Other Aidon 5856 Cable for system module local port RS232 (f) to 4-pin Aidon 6881 Cable for system module local port RS232 (m) to 4-pin Aidon 5895 Meter Reading Instruction pocket Plastic / Transparent Aidon Warning Sticker for Aidon 6810 Main Switch Bypass Languages FI, EN, SE, NO

8 AIDON PRODUCT CATALOG 8 (8) 1.4 Spare Parts Covers and Sealing Aidon 5890 Plastic seal for main cover sealing Can be used on all Aidon meters Aidon 5891 Terminal cover For Series phase meters Aidon 5892 Terminal cover For Series phase meters (without CB) Aidon 5893 Terminal cover For Series phase meter (with CB) Aidon 5894 Sealing screw Can be used on all Aidon meters Aidon 6001 System Module Front Cover Blank For Series 6000 System Modules Aidon System Module Front Cover With System Module Specific Sticker For Series 6000 System Modules Aidon 6002 System Module Inner Cover For Series 6000 System Modules Aidon 6003 Main Cover For Series phase Meters Aidon Terminal Cover With Meter Specific Connection Diagram For Series phase Meters Aidon Terminal Cover With Meter Specific Connection Diagram For Series phase meters Aidon 6004 Main Cover For Series phase Meters

SPA-ZC 17. Bus connection module SPA-ZC 17. User s manual and Technical description. Tx SC Rx BB BM MB MM SPA / RS 485 POWER SLAVE 1 MASTER 0

SPA-ZC 17. Bus connection module SPA-ZC 17. User s manual and Technical description. Tx SC Rx BB BM MB MM SPA / RS 485 POWER SLAVE 1 MASTER 0 SPA-ZC 17 Bus connection module User s manual and Technical description 1 2 3 4 5 6 7 8 O N SPA / RS 485 SPA 1100000 RS 485 0011110 SLAVE 1 MASTER 0 Tx SC Rx 2 5 Uaux 80...265 V ~ 18...80 V SPA-ZC 17 RS

More information

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B. Vision OPLC Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V290-19-C30B and V290-19-T40B. General Description Vision OPLCs are programmable

More information

Quick Guide. Extra Communication Card

Quick Guide. Extra Communication Card Quick Guide Extra Communication Card Uninterruptible Power Supply System Version: 1.0 Table of Contents 1. Product Outlook... 3 2. Product Introduction... 3 2.2. RS232 port... 4 2.3. COMM. Slot... 4 2.4.

More information

4.5 Components for TV/SAT, telephone installations and Category DATATEL Series - TEL DATATEL Series - CAT5 DATATEL Series - TV/SAT

4.5 Components for TV/SAT, telephone installations and Category DATATEL Series - TEL DATATEL Series - CAT5 DATATEL Series - TV/SAT Components for TV/SAT, telephone installations and Category 5 DATATEL - TEL DATATEL - CAT5 DATATEL - TV/SAT 7 7 Components for telephone installations FIXED TELEPHONE SOCKETS Type RJ Socket 6/ surface

More information

BreezeMAX Wi² and BreezeACCESS Wi² Quick Installation Guide

BreezeMAX Wi² and BreezeACCESS Wi² Quick Installation Guide This Quick Installation Guide is intended for experienced installers. For more information refer to the relevant sections in the BreezeMAX Wi² and BreezeACCESS Wi² System Manual. Wi² Package Content Check

More information

Teslights Hybrid Lighting SCALAMAX Protocol CA10 Head End Series. Technical Manual, DM

Teslights Hybrid Lighting SCALAMAX Protocol CA10 Head End Series. Technical Manual, DM SCALAMAX Protocol CA10 Head End Teslights Hybrid Lighting SCALAMAX Protocol CA10 Head End Series Technical Manual, DM15-3841 Document Number: IN-0000033-R01 Copyright Teslights, LLC 2010-2020 Compliant

More information

Access Terminal IF-800

Access Terminal IF-800 95-10287 IF-800_1312_3 Access Terminal IF-800 1 Slave Terminal IF-800 Thank you for using a terminal of the series IF-800 for recording access data. Scope of Delivery: Slave terminal IF-800. I/O controller

More information

H704-42(H)(E), H704-42/1(H)(E)

H704-42(H)(E), H704-42/1(H)(E) POWER MONITORING INSTALLATION GUIDE H704-42(H)(E), H704-42/1(H)(E) Branch Current Monitor DANGER NOTICE Installer's Specifications General: Operating Temp. Range 0 to 60 C (32 to 140 F) (

More information

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Uni-COM Modules Installation Guide UAC-01RS2,UAC-02RS2,UAC-02RSC Uni-COM is a family of communication modules that are compatible with the UniStream control platform. This guide provides basic installation

More information

Extra Communication Card Quick Start Guide

Extra Communication Card Quick Start Guide Extra Communication Card Quick Start Guide www.xpcc.com 2018. All rights reserved. (Rev 2/23/18) 1. Product Outlook... 3 2. Product Introduction... 3 2.2. RS232 port... 4 2.3. COMM. Slot... 4 2.4. Dry

More information

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Uni-I/O Modules Installation Guide UID-0808R, UID-0808T, UID-1600,UID-0016R, UID-0016T Uni-I/O is a family of Input/Output modules that are compatible with the UniStream control platform. This guide provides

More information

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Uni-I/O Wide Modules Installation Guide UID-W1616R, UID-W1616T Uni-I/O Wide is a family of Input/Output modules that are compatible with the UniStream control platform. Wide Modules are 1.5 times as wide

More information

Teslights Hybrid Lighting SCALAMAX Protocol LX-12D Gateway. Document Number: IN R01 Copyright Teslights, LLC

Teslights Hybrid Lighting SCALAMAX Protocol LX-12D Gateway. Document Number: IN R01 Copyright Teslights, LLC SCALAMAX Protocol LX-10 Series Gateways Teslights Hybrid Lighting SCALAMAX Protocol LX-12D Gateway Document Number: IN-0000033-R01 Copyright Teslights, LLC 2010-2020 Compliant Index Warning... 2 Disclaimer...

More information

SPA-ZC 200/SPA-ZC 202 IEC /SPA-gateway Modules. Installation Manual

SPA-ZC 200/SPA-ZC 202 IEC /SPA-gateway Modules. Installation Manual Issued: 29.03.2001 Version: A/29.03.2001 Checked: M.K. Approved: We reserve the right to change data without prior notice. Contents: 1. Safety information...4 2. Introduction...5 2.1. Contents of delivery...5

More information

Configuration and Interoperability Guide for IEC for the SEL-751 Feeder Protection Relay. July 10, 2015

Configuration and Interoperability Guide for IEC for the SEL-751 Feeder Protection Relay. July 10, 2015 Configuration and Interoperability Guide for IEC 60870-5-103 for the SEL-751 Feeder Protection Relay July 10, 2015 Contents 1 Interoperability... 3 1.1 Physical Layer... 3 Electrical Interface... 3 Optical

More information

NPort S8000 Series Quick Installation Guide

NPort S8000 Series Quick Installation Guide NPort S8000 Series Quick Installation Guide Edition 6.0, March 2016 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777 Fax: 1-714-528-6778

More information

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any

More information

Amano (itrt) Intelligent Twin Reader Terminal INSTALLATION MANUAL

Amano (itrt) Intelligent Twin Reader Terminal INSTALLATION MANUAL MODEL NUMBER: XRT910-0-0-AC-XX XRT920-0-0-AC-XX AMANO itrt Amano (itrt) Intelligent Twin Reader Terminal INSTALLATION MANUAL SPECIFICATIONS Working Environment Plastic Housing... Power Designed to work

More information

5KW Parallel Installation Guide

5KW Parallel Installation Guide 5KW Parallel Installation uide 1. Introduction This inverter can be used in parallel with maximum 6 units. The supported maximum output power is 60KW/60KVA. 2. Parallel cable You will find the following

More information

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B. Vision OPLC Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V290-19-C30B and V290-19-T40B. General Description Vision OPLCs are programmable

More information

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Uni-I/O Modules Installation Guide UID-0808THS Uni-I/O is a family of Input/Output modules that are compatible with the UniStream control platform. This guide provides basic installation information for

More information

Technical Manual for RTCU M10 / M10G

Technical Manual for RTCU M10 / M10G Technical Manual for RTCU M10 / M10G Version 1.04 Introduction This manual contains technical documentation allowing easy installation and use of the RTCU M10 / M10G unit. In the following text RTCU M10

More information

SATEL-LP-AI4. I/O extension module, 4 analog current inputs. Data sheet. 1 Description

SATEL-LP-AI4. I/O extension module, 4 analog current inputs. Data sheet. 1 Description I/O extension module, analog current inputs Data sheet 1069_en_00 SATEL 015-10-7 1 Description The I/O extension module can be used in conjunction with SATEL-LP wireless modules. In a station structure,

More information

Power Supply and Fan Module Installation

Power Supply and Fan Module Installation 3 CHAPTER This chapter describes how to remove and install a new or replacement power supply or fan module in a Catalyst 3750-E or Catalyst 3560-E switch. See these sections: Installation Overview, page

More information

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

See instructions to download and install the latest version of LinkBoxMB and the user's manual at Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any

More information

Older Compaq UPS Family - Identifying Serial Communication Cables

Older Compaq UPS Family - Identifying Serial Communication Cables Older Compaq UPS Family - Identifying Serial Communication Cables In this document: Overview Cables Supplied 6 Ft. Communication Cable 12 Ft. Communication Cable Older Compaq UPS Family Communication Port

More information

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any

More information

BLUE 3 INSTALLATION GUIDE

BLUE 3 INSTALLATION GUIDE BLUE 3 INSTALLATION GUIDE CATCH Power BLUE 3 Installation manual - Page 1 IMPORTANT This product must be installed by a licensed electrician. This product must be installed according to the AS3000 Australian

More information

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

See instructions to download and install the latest version of LinkBoxMB and the user's manual at Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any

More information

Power Entry. Version 1.0 June 2, 2017

Power Entry. Version 1.0 June 2, 2017 Power Entry Version 1.0 June 2, 2017 1 Overview The Power Entry board is used for distributing AC power and 4 different DC voltages, generally 5v, 12v, 15v, and high voltage (typically 48v or 70v). A 12v

More information

Common Departures Interconnecting Facilities Requirements

Common Departures Interconnecting Facilities Requirements Welcome to our e-rew Express. In our last issue, we discussed the common departures on metering installation requirements. This time, we would like to discuss the common departures on the customer low

More information

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Vision OPLC V350-35-R34/V350-J-R34 Installation Guide The Unitronics V350-35-R34/V350-J-R34 offers the following onboard I/Os: 22 Digital Inputs, configurable via wiring to include 2 Analog and 3 HSC/Shaft-encoder

More information

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

See instructions to download and install the latest version of LinkBoxMB and the user's manual at Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any

More information

Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any

More information

ATTINGIMUS RADAR AT-CAS S

ATTINGIMUS RADAR AT-CAS S ATTINGIMUS RADAR AT-CAS100-3580S AT-CAS100-3580S COLLISION AVOIDANCE RADAR SYSTEM SET - ULTRA SMALL Can be used as a stand-alone or in a master & slave set March 2013 V1 3,5 cm size comparison 3,5 cm FEATURES

More information

USER MANUAL INSTALLATION MANUAL. Isolation transformers. ITR Isolation Transformer 7000 W 230V/32A

USER MANUAL INSTALLATION MANUAL. Isolation transformers. ITR Isolation Transformer 7000 W 230V/32A USER MANUAL INSTALLATION MANUAL Isolation transformers ITR000702000 Isolation Transformer 7000 W 230V/32A Victron Energy B.V. The Netherlands General phone: +31 (0)36 535 97 00 Customer support desk: +31

More information

MAINS DISTRIBUTION UNIT MDU14-CO

MAINS DISTRIBUTION UNIT MDU14-CO MAINS DISTRIBUTION UNIT MDU14-CO Dual Input Auto Changeover 14 Output Mains Distribution Unit. Handbook Television Systems Limited. Vanwall Road, Maidenhead, Berkshire, SL6 4UB Telephone +44 (0)1628 676200,

More information

See instructions to download and install the latest version of LinkBoxLON and the user's manual at

See instructions to download and install the latest version of LinkBoxLON and the user's manual at Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any

More information

GSM MODEM X TECHNICAL PROPERTIES. Operating Voltage : 85V - 300V AC Operating Frequency : 50Hz. / 60Hz.

GSM MODEM X TECHNICAL PROPERTIES. Operating Voltage : 85V - 300V AC Operating Frequency : 50Hz. / 60Hz. GSM MODEM X PICTURES X TECHNICAL PROPERTIES Operating Voltage : 85V - 300V AC Operating Frequency : 50Hz. / 60Hz. GSM-MOD Operating Temperature : 0ºC 55ºC ESD Protection : 10kV Resistance to Impact : 4KV

More information

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318 ATS-16 HV Automatic Transfer Switch 16A / 230Vac USER MANUAL V090318 SAFETY Intended use The ATS-16 HV device serves as a power source selector to provide improved power supply for connected loads. ATS-16

More information

Wise HP33 THREE PHASE HIGH PRECISION AVR SURVO-MOTOR AUTOMATIC VOLTAGE STABILIZER

Wise HP33 THREE PHASE HIGH PRECISION AVR SURVO-MOTOR AUTOMATIC VOLTAGE STABILIZER Wise HP33 THREE PHASE HIGH PRECISION AVR SURVO-MOTOR AUTOMATIC VOLTAGE STABILIZER LEN.MAN.STA.111 Rev.4.00/2010 CONTENTS 1. SAFETY INSTRUCTIONS 1 2. INTRODUCTION 2 3. FRONT PANEL AND CONNECTION BOARD 3

More information

Digital I/O Module. Impro (DIO) Digital I/O Module INSTALLATION MANUAL

Digital I/O Module. Impro (DIO) Digital I/O Module INSTALLATION MANUAL COMPONENT CODES: HMI700-1-0-NN-XX HMI701-1-0-NN-XX Digital I/O Module Impro (DIO) Digital I/O Module Specifications INSTALLATION MANUAL The DIO is a Cluster Expansion Module that works in conjunction with

More information

Impulse switching module

Impulse switching module 8 156 PTM14250A-P DESIGO I/O modules Impulse switching module PTM14250A-P for AC 24250 V, single-stage, with manual switches, double module Signal converter for connection to P-bus and for delivering impulse

More information

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

See instructions to download and install the latest version of LinkBoxMB and the user's manual at Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any

More information

OnCell G3100 Series Quick Installation Guide

OnCell G3100 Series Quick Installation Guide OnCell G3100 Series Quick Installation Guide Edition 4.1, August 2016 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777 Fax: 1-714-528-6778

More information

Vision OPLC V TR6/V350-J-TR6

Vision OPLC V TR6/V350-J-TR6 Vision OPLC V350-35-TR6/V350-J-TR6 Installation Guide The Unitronics V350-35-TR6/V350-J-TR6 offers the following onboard I/Os: 8 Digital Inputs, configurable via wiring to include 2 Analog (current/voltage)

More information

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any

More information

Teslights Hybrid Lighting SCALAMAX Protocol LX10 Gateway Series. Document Number: IN R01 Copyright SCALAMAX, LLC

Teslights Hybrid Lighting SCALAMAX Protocol LX10 Gateway Series. Document Number: IN R01 Copyright SCALAMAX, LLC SCALAMAX Protocol LX-10 Series Gateways Teslights Hybrid Lighting SCALAMAX Protocol LX10 Gateway Series Document Number: IN-0000033-R01 Copyright SCALAMAX, LLC 2010-2020 Compliant Index Warning... 2 Disclaimer...

More information

Switched Mode Power Supply Operating manual PAP800

Switched Mode Power Supply Operating manual PAP800 Features: Switched mode power supply Wide output 0 144Vdc Analog control by an external 0 5Vdc Power failure alarm output Master-slave connection Powerfinn PAP series is a high power, lightweight, advanced

More information

one cool inverter. GT Series Solar Inverter Quick Install Guide v1.4

one cool inverter. GT Series Solar Inverter Quick Install Guide v1.4 one cool inverter. GT Series Solar Inverter Quick Install Guide v1.4 This quick installation guide must be used in conjunction with the Installation Manual. For installation support contact your local

More information

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Uni-I/O Wide Modules Installation Guide UIS-WCB1 Uni-I/O Wide is a family of Input/Output modules that are compatible with the UniStream control platform. Wide Modules are 1.5 times as wide as Uni-I/O

More information

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Uni-I/O Modules Installation Guide UIA-0402N Uni-I/O is a family of Input/Output modules that are compatible with the UniStream control platform. This guide provides basic installation information for

More information

M-Bus Central Unit. Use

M-Bus Central Unit. Use 6 M-Bus Central Unit OZW The M-bus central unit is used for the remote readout, remote operation and supervision of an M-bus plant with a maximum of consumption meters and controllers featuring an M-bus

More information

P od o u d c u t line n : S D S D Inv n erter N I P P r P esent n ation

P od o u d c u t line n : S D S D Inv n erter N I P P r P esent n ation Product line : SD Inverter NPI Presentation Product Pure Sine Wave Inverter : SD series Parallel redundancy design for power expansion Automatic master mechanism to eliminate single unit failure Built-in

More information

Sensitive Earth-fault Relay SPAJ 111 C. Product Guide

Sensitive Earth-fault Relay SPAJ 111 C. Product Guide Issued: April 1999 Status: Update Version: C/12.04.2006 Data subject to change without notice Features Sensitive low-set neutral overcurrent stage with definite time characteristic High-set neutral overcurrent

More information

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies ADC7520 SERIES 1600W Battery Chargers and Power Supplies Wide output adjustment range 0 72VDC Analog control by external 0-5VDC voltage Temp.comp charging, sense as on option Power fail relay alarm Master-Slave

More information

PRO-1250D CT MID DIN rail three phase four wire energy meter.

PRO-1250D CT MID DIN rail three phase four wire energy meter. PRO-1250D CT MID DIN rail three phase four wire energy meter. 1.1 Safety instructions 1.2 Foreword 1.3 MID certificate 1.4 Performance criteria 1.5 Specifications 1.6 Basic errors 1.7 Description 1.8 Dimensions

More information

PRO1250D CT M-bus MID DIN rail three phase four wire energy meter. User manual Version 1.11

PRO1250D CT M-bus MID DIN rail three phase four wire energy meter. User manual Version 1.11 PRO1250D CT M-bus MID DIN rail three phase four wire energy meter. User manual Version 1.11 1 Safety instructions...3 2 Foreword...4 3 MID certificate...5 4 CE certificates...6 6 Performance criteria...8

More information

HydroGuard 4 to 20 ma Output Module. For use with HydroGuard Water Quality Monitor and Controller

HydroGuard 4 to 20 ma Output Module. For use with HydroGuard Water Quality Monitor and Controller HydroGuard 4 to 20 ma Output Module For use with HydroGuard Water Quality Monitor and Controller Technician's Manual Installation, Operation, and Maintenance Guide Chapter 1: Preface... 3 1.1 Intended

More information

*****CAUTION/ATTENTION***** Before You Start...

*****CAUTION/ATTENTION***** Before You Start... Quickstart Guide 1. Introduction 2. Understanding Phases 4. Voltage Connection 5. Current Sensors 3. Network Connection 6. Commissioning 7. FAQs + Configuration *****CAUTION/ATTENTION***** Before You Start...

More information

PRO1250D CT MID DIN rail three phase four wire energy meter. User manual Version 1.5

PRO1250D CT MID DIN rail three phase four wire energy meter. User manual Version 1.5 PRO1250D CT MID DIN rail three phase four wire energy meter. User manual Version 1.5 1 Safety instructions...3 2 Foreword...4 3 CE certificates...5 4 MID certificate...7 5 Performance criteria...8 6 Specifications...8

More information

Key Switch. Document version: 1.5 (Updated 02 May 2017)

Key Switch. Document version: 1.5 (Updated 02 May 2017) Key Switch Document version: 1.5 (Updated 02 May 2017) Contents ii Contents 1 Key Switch R10S.3... 4 2 Quick Guides...4 2.1 Controlling an Electric Lock...5 2.2 Controlling an Alarm System... 5 2.3 Controlling

More information

Industrial Gateway Solutions

Industrial Gateway Solutions Industrial Gateway 10 Selection Guide 10-2 Wireless Serial Device s EKI-1361 EKI-1362 Dual Ethernet Serial Device s EKI-1521/CI/I EKI-1522/CI/I EKI-1524/CI/I EKI-1528/T EKI-1526/T Modbus Gateways EKI-1221/CI/I

More information

OPERATING PRINCIPLES FOR PHOTOELECTRIC SENSORS

OPERATING PRINCIPLES FOR PHOTOELECTRIC SENSORS OPERATING PRINCIPLES FOR PHOTOELECTRIC SENSORS Photoelectric These sensors use light sensitive elements to detect objects and are made up of an emitter (light source) and a receiver. Four types of photoelectric

More information

Model HM-535 Power Supply Installation and Service Instructions

Model HM-535 Power Supply Installation and Service Instructions Model HM-535 Power Supply Installation and Service Instructions 430-535 0104 2004 Heritage MedCall, Inc SENTRY INSTALLATION & SERVICE INSTRUCTIONS POWER SUPPLY UNIT Model HM-535 IMPORTANT SAFETY INSTRUCTIONS

More information

Feeder protection relay SPAA 121 C. Product Guide

Feeder protection relay SPAA 121 C. Product Guide Issued: April 1999 Status: Updated Version: C/06.03.2006 Data subject to change without notice Features Two-phase low-set phase overcurrent unit with definite time or inverse time characteristic Two-phase

More information

GSM-X. Communication module. Quick installation guide. Full manual is available on Firmware version 1.02 gsm-x_sii_en 08/18

GSM-X. Communication module. Quick installation guide. Full manual is available on   Firmware version 1.02 gsm-x_sii_en 08/18 GSM-X Communication module Quick installation guide Full manual is available on www.satel.eu Firmware version 1.02 gsm-x_sii_en 08/18 SATEL sp. z o.o. ul. Budowlanych 66 80-298 Gdańsk Poland tel. +48 58

More information

Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any

More information

PRO2DM DIN rail single phase two wire energy meter

PRO2DM DIN rail single phase two wire energy meter PRO2DM DIN rail single phase two wire energy meter User manual Version 1.04 1 Safety instructions...3 2 Foreword...4 3 CE Certificate...5 4 Performance criteria...6 5 Specifications...6 6 Basic errors...6

More information

Screen 2.4" 3.5" Color Touch 4.3" Color Touch. RS232/485 Yes Yes Yes Yes Yes* USB device, mini-b Com Ports, separate order, user-installed

Screen 2.4 3.5 Color Touch 4.3 Color Touch. RS232/485 Yes Yes Yes Yes Yes* USB device, mini-b Com Ports, separate order, user-installed V130-33-TR20/V130-J-TR20 V350-35-TR20/V350-J-TR20 V430-J-RH2 Installation Guide 12 Digital Inputs, including 2 Analog, 3 HSC/Shaft-encoder inputs 6 Relay Outputs 2 high-speed npn Transistor Outputs (TR20

More information

ABB Drives. User s Manual Modbus Adapter Module FMBA-01

ABB Drives. User s Manual Modbus Adapter Module FMBA-01 ABB Drives User s Manual Modbus Adapter Module FMBA-01 Modbus Adapter Module FMBA-01 User s Manual 3AFE68586704 REV A EN EFFECTIVE: 27.06.2005 2005 ABB Oy. All Rights Reserved. 5 Safety instructions

More information

This guide provides basic information for Unitronics Models 230/260/280/290 (Non-color Screens).

This guide provides basic information for Unitronics Models 230/260/280/290 (Non-color Screens). Vision OPLC Installation Guide Models 230/260/280/290 (Non-color Screens) This guide provides basic information for Unitronics Models 230/260/280/290 (Non-color Screens). General Description Vision OPLCs

More information

Socket for Time Delay Relays

Socket for Time Delay Relays Socket Socket Time Delay Relays CA System socket -pole, with white cover and plug-in connector. (standard delivery) EC Economy socket -pole CS Socket -pole Snaped cover sheet with wiring diagram. (backside

More information

USER MANUAL. SATEL i-link. I/O-converter. Version 1.4

USER MANUAL. SATEL i-link. I/O-converter. Version 1.4 USER MANUAL SATEL i-link I/O-converter Version 1.4 TABLE OF CONTENTS TABLE OF CONTENTS... 2 IMPORTANT NOTICE... 3 PRODUCT CONFORMITY... 4 WARRANTY AND SAFETY INSTRUCTIONS... 5 1 GENERAL... 6 1.1 SATEL

More information

MOTOR PROTECTION CIRCUIT BREAKERS

MOTOR PROTECTION CIRCUIT BREAKERS MOTOR PROTECTION CIRCUIT BREAKERS PAGE -2 PAGE -2 SMA Thermal trip adjustment ranges 9-32A (5 choices) Breaking capacity Icu at 400V: 50kA Suitable for mounting in consumer switchboards with minimum 58mm

More information

Catalog. Arc Guard System TM TVOC-2

Catalog. Arc Guard System TM TVOC-2 Catalog Arc Guard System TM TVOC-2 Introduction An even better Arc Guard System TVOC-2, ABB s latest Arc Monitor, builds on the well known TVOC design. Its new functions and features improve an already

More information

Remote communication options include IEC Ethernet communications or Modbus (RS485).

Remote communication options include IEC Ethernet communications or Modbus (RS485). 2019 The MELPRO D series relay is suitable for feeder protection, motor protection and transformer protection applications. The relay offers multiple step time grading for over-current protection co-ordination.

More information

ABB Drives. User s Manual. Modbus Adapter Module RMBA-01

ABB Drives. User s Manual. Modbus Adapter Module RMBA-01 ABB Drives User s Manual Modbus Adapter Module RMBA-01 Modbus Adapter Module RMBA-01 User s Manual 3AFE 64498851 REV A EN EFFECTIVE: 1.3.2002 2002 ABB Oy. All Rights Reserved. Safety instructions Overview

More information

Installation Instructions for the AUTOcard-SA System

Installation Instructions for the AUTOcard-SA System Installation Instructions for the AUTOcard-SA System IMPORTANT NOTICE The AUTOcard-SA system is a very reliable and easy to use system. However, damage could occur if it is installed incorrectly. In particular,

More information

TraceTek Leak Detection Master Module Installation Instructions TOOLS REQUIRED STORAGE

TraceTek Leak Detection Master Module Installation Instructions TOOLS REQUIRED STORAGE TTDM-128 TraceTek Leak Detection Master Module Installation Instructions TRACETEK APPROVALS AND CERTIFICATIONS TYPE NM General Signaling Equipment 76LJ GENERAL INFORMATION Please read these instructions

More information

F1000 User's Manual. (Version: V1.01)

F1000 User's Manual. (Version: V1.01) (Version: V1.01) Contents Chapter 1 Overview... 2 Chapter 2 Installation... 3 2.1 Installation guide... 3 2.1.1 Installation position... 3 2.1.2 NEMA4 standard installation... 3 2.1.3 Environment precautions...

More information

MC 11 EB-2 Power supply cabinet with external bus, AC version

MC 11 EB-2 Power supply cabinet with external bus, AC version MC 11 EB-2 Power supply cabinet with external bus, AC version USER/MAINTENANCE MANUAL 1 SLOT 0 SLOT 1 SLOT 2 SLOT 3 SLOT 4 SLOT 5 SLOT 6 SLOT 7 SLOT 8 SLOT 9 SLOT 10 SLOT 11 EB-2 (a) MC11 (b) (c) Figures

More information

LON bus communication devices 1MRS MBG Page 1 Issued: April 1999 Status: New Data subject to change without notice

LON bus communication devices 1MRS MBG Page 1 Issued: April 1999 Status: New Data subject to change without notice LON bus communication devices Page 1 Issued: April 1999 Status: New Data subject to change without notice Features The LonWorks Network is an open system adapted for various application areas Peer-to-peer

More information

Earth-fault Relay SPAJ 110 C. Product Guide

Earth-fault Relay SPAJ 110 C. Product Guide Issued: April 1999 Status: Updated Version: C/12.04.2006 Data subject to change without notice Features Low-set neutral overcurrent stage with definite time or inverse time characteristic High-set neutral

More information

Expansion Module HZS 541-1S

Expansion Module HZS 541-1S Expansion Module HZS 541-1S 12.10.2015 Page 1 System Description The external HZS 541-1S expansion module provides users of biomass heating systems with additional 230 V AC relay outputs, analog inputs

More information

MODEM for REMOTE SWITCH CONTROL V1.20

MODEM for REMOTE SWITCH CONTROL V1.20 User manual MODEM for REMOTE SWITCH CONTROL V1.20 UASAGE NOTICE This software / document / material are property of Kurolikar Automation Research Labs (KARL PL) Pvt Ltd. It has been provided for the exclusive

More information

OPLC Installation Guide

OPLC Installation Guide Samba OPLC SM35-J-R20/SM43-J-R20 SM70-J-R20 SM35-J-T20/SM43-J-T20 SM70-J-T20 OPLC Installation Guide 12 Digital Inputs, include 1 HSC/Shaft-encoder Input, 2 Analog inputs (only when the digital inputs

More information

INSTRUCTION MANUAL A141 High Level Audible Warning System

INSTRUCTION MANUAL A141 High Level Audible Warning System 24V DC (18V to 30V DC range) 115 or 230VAC (90V to 264V AC range) Operating Temp: -20 to +55 C IP Rating: IP65 Marking: 3) Installation Requirements 1) Introduction The A141 high level audible warning

More information

Power Supply Installation

Power Supply Installation Power Supply Module Overview, on page Installation Guidelines, on page 4 Installing or Replacing an AC Power Supply, on page 6 Installing a DC Power Supply, on page 7 Finding the Power Supply Module Serial

More information

EZ864 UMTS Terminal Telit Cellular GSM Engine

EZ864 UMTS Terminal Telit Cellular GSM Engine EZ864 UMTS Terminal Telit Cellular GSM Engine Version: 01.01 EZ864 UMTS Terminal_HD_V01.01 06.Mar.2008-1 - Hardware Interface Description 1. Hardware Features of the EZ864 UMTS Terminal Feature Implementation

More information

Power Factor Controller

Power Factor Controller Elnet LTC Power Factor Controller Table of Contents CHAPTER 1 Electrical Wiring...3 1.1 Electrical Connections...3 1.2 Electrical Wiring Diagrams...5 1.3 Indication Leds...7 1.4 Test Capacitors Screen...8

More information

ENERGY /// TE'S CROMPTON INSTRUMENTS TE'S CROMPTON INSTRUMENTS CURRENT TRANSFORMERS

ENERGY /// TE'S CROMPTON INSTRUMENTS TE'S CROMPTON INSTRUMENTS CURRENT TRANSFORMERS ENERGY /// TE'S CROMPTON INSTRUMENTS TE'S CROMPTON INSTRUMENTS CURRENT TRANSFORMERS 2 ENERGY /// TE'S CROMPTON INSTRUMENTS 3 Table of contents I. Tape Wound Measuring and Protection Current MR Series Measuring

More information

CA-A480-A Elevator Controller. Reference & Installation Manual

CA-A480-A Elevator Controller. Reference & Installation Manual CA-A480-A Elevator Controller Reference & Installation Manual TABLE OF CONTENTS INTRODUCTION.................................................................. 4 Introduction.............................................................................................

More information

22 Digital Inputs, including 2 Analog, 2 HSC/Shaft-encoder inputs 16 Transistor Outputs

22 Digital Inputs, including 2 Analog, 2 HSC/Shaft-encoder inputs 16 Transistor Outputs Vision PLC+HMI V130-33-T38/V130-J-T38 V350-35-T38/V350-J-T38 V430-J-T38 Installation Guide 22 Digital Inputs, including 2 Analog, 2 HSC/Shaft-encoder inputs 16 Transistor Outputs General Description All

More information

GC 055. GSM Remote Monitoring. Operating and installation instructions

GC 055. GSM Remote Monitoring. Operating and installation instructions GSM Remote Monitoring Operating and installation instructions GC 055 GSM, GPRS Programmable Communicator Transmits input conditions/controls outputs Measures analogue data Access control system/dallas

More information

dynamic white par manual

dynamic white par manual dynamic white par manual V2.0 AUGUST 2017 table of CONTENTS Dimensions 1 Safety information 2 Fixture overview 4 Introduction 5 AC power 5 Power voltage 5 Power cables 6 Relaying power to other devices

More information

ABB LVP&S Training AC500 to EMAX Modbus RTU ABB Automation Technologies

ABB LVP&S Training AC500 to EMAX Modbus RTU ABB Automation Technologies ABB LVP&S Training AC500 to EMAX Modbus RTU ABB Automation Technologies Revision Date: Feb 16,2009 Objective Using AC500 to communicate to Emax Breaker with Modbus RTU. This intermediate level course demonstrates

More information

IF-80x Outdoor Terminal

IF-80x Outdoor Terminal 95-10330_IF-800 V2016-10-20 Outdoor Terminal IF-80x Outdoor Terminal 1 IF-800 Outdoor / IF-801 We are pleased that you have decided to use a terminal of the IF-80x series for recording access data. Scope

More information

PCIEMODBOX232 RS232 to PCI Module Box Introduction

PCIEMODBOX232 RS232 to PCI Module Box Introduction PCIEMODBOX232 RS232 to PCI Module Box Introduction This high performance PCI (or PCIe) RS232/422/485 Combo Expansion Module product includes an expansion module box, a PCI (or PCIe) Host Adapter and a

More information

EZ864 G. Telit Cellular GSM/UMTS Engine. Hardware guide Version: Update: 27. APR.2009 EZ864 G_Hardware Guide_V

EZ864 G. Telit Cellular GSM/UMTS Engine. Hardware guide Version: Update: 27. APR.2009 EZ864 G_Hardware Guide_V EZ864 G Telit Cellular GSM/UMTS Engine Hardware guide Version: 04.01 Update: 27. APR.2009 EZ864 G_Hardware Guide_V4. - 1 - Hardware Interface Description 1. Hardware Features of the EZ864 G Feature Implementation

More information