1 MST2000 Loop Powered Multivariable SMARTFLOW Transmitter
2 MST2000 Loop Powered Multivariable SMARTFLOW Transmitter Brandt Instruments MST2000 Series Loop Powered Multivariable SMARTFLOW Transmitter sets new standards for draft range Differential Pressure / Mass Flow measurement of Air and Gas Flows. Combining Brandt s twenty plus years of experience in industrial process control with state of the art digital signal processing technology, the MST2000 is the most versatile, reliable, cost-effective and simplest to operate loop powered multivariable transmitter in the industry. The MST2000 is a HART compatible, loop powered (two wire ) device available in either a compact, NEMA 1 configuration for wall or panel mounting or a rugged fiberglass NEMA 4X enclosure for hostile environments. With a turndown capability of 10:1 the available draft ranges can be turned as low as 0.01 Inches W.C. full scale. Fully programmable and user friendly, the MST2000 is capable of producing and displaying signals for Differential Pressure (Inches of Water Column) or for Flow (ACFM, SCFM, Lb/Hr). Optional isolated 4-20 ma inputs are available for Absolute Pressure, External Temperature and a second Differential Pressure Transmitter. A HART Communications Module and Digital I/O Module are also available. All the optional modules can be installed in the field by the end user. MST2000 Standard Features High Performance at Ultra Low Spans: Standard spans from 0.10 to 50 Inches Water Column are available (custom and compound ranges are also possible) with a total accuracy of 0.15% of Span. Thermal Compensated Output: Each MST2000 has an onboard temperature sensor and is thermally compensated at the factory to eliminate thermal effects. Password Protection: The MST2000 provides for password security so that modifications to program variables can only be made by authorized personnel. Adjustable Damping: The standard time constant is 500 msec but is user programmable from 0.5 to 5 seconds in 0.5 second intervals. LCD Display and Integral Keypad: A large, high contrast, easy to read LCD display and integral keypad allow the user to effortlessly program the MST2000 for optimal process conditions. Programmable Alarms: User selectable transmitter fault conditions can be programmed to set the 4-20 ma output to a low 3.9 ma or high 21.0 ma state. User can also select HI/LO process conditions to control the optional digital outputs. RTD Input: A non-isolated 4 wire RTD input connection is supplied for external temperature input. Integral Test Jack: Allows the user to monitor the ma output of the MST2000 without disconnecting the loop. Programmable Constants: When external temperature and absolute pressure signals are unavailable, these variables can be programmed in as constants, allowing the end user to select an output signal which will represent ACFM, SCFM or Lb/Hr. Without these constants, or external inputs, only the D.P. will be a true signal. MST2400: NEMA 4X Enclosure MST2000 Isolated Input Modules The MST2000 can be optionally configured with up to three (3) Isolated 4-20 ma input modules for true mass flow measurement. The input range for each input module is software rangeable by the end user. Any combination of the three can be mounted at the factory or field mounted by the user to upgrade process capabilities. Temperature Input Option: Accepts a 4-20 ma input from an external temperature transmitter. Absolute Pressure Input Option: Accepts a 4-20 ma input from an external absolute pressure transmitter. An optional integral absolute pressure transmitter can be mounted in the MST2400 enclosure. External Differential Pressure Input Option: Accepts a 4-20 ma input from an external differential pressure transmitter. A second differential input can be used to extend the available range to provide up to 2% flow rate accuracy over a 25:1 flow range. MST2000 Digital I/O Module The MST2000 can be optionally configured with (1) one digital input and (2) two digital outputs. This option is capable of either being installed at the factory or in the field. Digital Input: Accepts external signal to trigger events, such as a blowdown sequence. The MST2000 will hold the last output signal throughout the duration of the event. Digital Outputs: For control of external devices (AutoZero Valve, High Pressure Blowdown Systems, Alarm Circuits, etc.). HART Communications Module An optional HART Communication Module can be installed to provide industry standard HART access to the MST2000. This option can be installed at the factory or in the field.
3 Brandt Instruments, Inc., Fuquay, North Carolina USA (919) MODE EDIT Run Alarm ABS. PRES. STATUS STATUS STATUS EXT. TEMP. Brandt Instruments, Inc. Fuquay, North Carolina USA LOOP+ LOOP- RTD+ SEN+ SEN- RTD- +EXTIN 1- +EXTIN 2- +EXTIN 3- +DI1- + DO1- +DO2- RX/TX+ GNDRX/TX- TM Auto Zero Blowdown EXT. DP Brandt Instruments, Inc., Fuquay, North Carolina USA (919) Model: MST S1P 4-20mA Loop Powered Serial Number: Range: 0 to 0.25 Inches W.C Abs.Prs Temp. ExtDP LOOP RTD SEN SEN RTD EXTIN 1 EXTIN 2 EXTIN 3 DI 1 DO 1 DO 2 RX/TX INC. DEC. Brandt Instruments, Fuquay, North Carolina 27526, USA (919) Dimensions 2.33 Inches 59.2 mm 6.25 Inches mm 6.75 Inches mm TM MST2000 Multivariable SMARTFLOW Transmitter MODE INC. 7.0 Inches mm EDIT Run Alarm INWC DEC. Auto Zero Blowdown 6.5 Inches mm _TEST + ABS. PRES. STATUS STATUS STATUS Model: MST S1P Serial Number: EXT. TEMP. Brandt Instruments, Inc. Fuquay, North Carolina USA 4-20mA Loop Powered Range: 0 to 0.25 Inches W.C EXT. DP Abs.Prs + + Temp. + ExtDP + _ + _ + _ + _ LOOP RTD SEN SEN RTD EXTIN 1 EXTIN 2 EXTIN 3 DI 1 DO 1 DO 2 RX/TX LCD Display & Integral Keypad HI LOW 1/8"NPTF Process Connections Bottom View LOOP+ LOOP- RTD+ SEN+ SEN- RTD- +EXTIN 1- +EXTIN 2- +EXTIN 3- +DI1- + DO1- +DO2- RX/TX+ GNDRX/TX- HI LOW Status Light & Resets for Isolated Input Options Side View Test Jacks Top View 0.25 Inch (6.35mm) Dia. Mounting Holes (4X) MST2100: NEMA 1 Enlcosure Top View 0.25 Inch Dia. Mounting Holes (4X) Inches mm Inches mm MST2000 Multivariable SMARTFLOW Transmitter INWC Inches 233.4mm Inches mm _TEST Inches mm Brandt MST S1P Serial No: to 0.25 INWC 4-20 ma Loop Powered Output Signal HI LOW 1/2" Conduit Connection Bottom View Window 1/4"NPTF Process Connections Located on MST2000 Front View Recessed Captive Screws Optional 2.5" Pipe Mount Side View With Optional 2.5" Pipe Mount MST2400: NEMA 4X Fiberglass Enclosure
4 SERIES: LOOP POWERED MULTIVARIABLE SMARTFLOW TM TRANSMITTER MST2000 Model Number Description MST21 = MST2100, NEMA 1 Panel Mount Enclosure, Differential Pressure Configuration & Non-isolated 4 Wire RTD Input Standard. MST24 = MST2400, NEMA 4X, Fiberglass Enclosure, Differential Pressure Configuration & Non-isolated 4 Wire RTD Input Standard. ISOLATED INPUT MODULE: Absolute Pressure Transmitter 0 = None 1 = Isolated Input Module: Accepts 4-20mA input signal from an External Absolute Pressure Transmitter. 2 = Isolated Input Module with Integral Absolute Pressure Transmitter, 0-25 PSI range standard. Consult factory for other ranges. MST2400 only. Requires external 24V source. ISOLATED INPUT MODULE: Temperature Transmitter 0 = None 1 = Isolated Input Module: Accepts 4-20mA input signal from an External Temperature Transmitter. ISOLATED INPUT MODULE: 2 nd Differential Pressure Transmitter 0 = None 1 = Isolated Input Module: Accepts 4-20mA input signal from a 2 nd External D.P. Transmitter. COMMUNICATIONS MODULE 0 = None H = HART Communications Module. Availability pending, consult factory. DIGITAL I/O MODULE 0 = None D = Digital I/O Module with 1 Input, 2 Outputs. Availability pending, consult factory. PRESSURE RANGES 1S = Standard Range 1...Max. Span: 0 to 0.10 W.C. Turndown to W.C. (10:1). 2S = Standard Range 2...Max. Span: 0 to 0.25 W.C. Turndown to W.C. (10:1). 3S = Standard Range 3...Max. Span: 0 to 1.00 W.C. Turndown to 0.10 W.C. (10:1). 4S = Standard Range 4...Max. Span: 0 to 4.00 W.C. Turndown to 0.40 W.C. (10:1). 5S = Standard Range 5...Max. Span: 0 to 16.0 W.C. Turndown to 1.60 W.C. (10:1). 6S = Standard Range 6...Max. Span: 0 to 50.0 W.C. Turndown to 5.00 W.C. (10:1). CR = Compound Range...Consult factory. Supply desired Compound Range. All maximum pressure ranges have a turndown of 10:1. Specify Pressure Range # in model number (example 1S or CR). Standard Ranges: MST2000 will be calibrated at Maximum Span. If an Initial Range Setting is desired, supply with order and unit will be shipped with this Initial Range preset. (Example: 3S set to 0 to 0.5 W.C.). Compound Ranges: MST2000 will be calibrated at desired Compound Range. Supply compound range with order (example: to W.C.). All spans will be calibrated in Inches of W.C. Other Units of measure will be converted to Inches of W. C. OUTPUT 1 = 4-20mA Output. 2 = 4-20mA Output with Integral 120VAC to 24VDC Power Supply. 120VAC Source Required. MST2400 only. OPTIONS 0 = None B = Integral High Pressure Blowdown System. MST2400 Only. Requires Digital I/O Module. 120VAC source required. Enclosure size will change. Consult Factory for specifications and availability. P = Continuous Purge to Flowmeter. MST2400 Only. Spans of 0.25 W.C. or greater. A filtered air supply source of 20 to 80 PSI is required. ACCESSORIES 0 = None P = Pipe Mount. MST2400 Only. MST H D 2S 1 0 P NOTE: For factory setup of the MST2000 s multivariable configuration, provide the following information with your order. Initial Span Setting of MST2000 in Inches of Water Column if other than the standard range. External parameters for Temperature, Pressure and 2nd Differential Pressure Transmitter (Input Range, Zero/Span Values, etc.). Flowmeter Parameters and conditions. Type of Flowmeter. Effective Area in Square Feet or Kfactor of Flowmeter. Minimum/Maximum range of flow, temperature and pressure. Please include units of measure. Type of medium, molecular weight and specific gravity or density. Desired milliamp output setting. Inches of Water, SCFM, etc. Tagging Information.
5 MST2000 Loop Powered Multivariable SMARTFLOW Transmitter LCD Display Increment & Decrement Buttons Mode & Edit Buttons Reset Button Status Light & Reset Button for Isolated Input Options Test Jack 1/8 NPTF Process Connections Mounting Plate MST2000 Multivariable Versatility The MST2000 s multivariable capabilities provide the necessary versatility required to satisfy today s demanding industrial process applications. With programmable constants, input/output options and communication features the MST2000 will concurrently measure and/or apply the numerous process variables for a true mass flow measurement. The MST2000 s configuration is user friendly and is accomplished through the integral keypad (no external software or hardware is required). Optional input, digital I/O and communication modules can be installed at the factory or in the field as required. MST2100: NEMA 1 Enclosure MST2000 Loop Powered Multivariable SMARTFLOW Transmitter Differential Pressure Spans from 0.01 to 50.0 Inch. W.C. with 10:1 Turndown Temperature 4 Wire RTD Input Standard Programmable Constant or Optional 4-20 ma Analog Input Absolute Pressure Programmable Constant or Optional 4-20 ma Analog Input nd 2 D.P. Transmitter Optional 4-20 ma Analog Input HART User Interface Integral Keypad Programmable LCD Display 4-20 ma Output User Selectable Inches W.C., SCFM, ACFM or Lbs./Hr.
6 MST2000 Loop Powered Multivariable SMARTFLOW Transmitter FUNCTIONAL SPECIFICATIONS Service: Pressure Ranges: Clean, dry, non-corrosive Air or Gas. Other media may be possible with the use of the Continuous Purge option. Consult factory. Standard Pressure Ranges Range 1: 0 to 0.10 W.C. Range 2: 0 to 0.25 W.C. Range 3: 0 to 1.0 W.C. Range 4: 0 to 4.0 W.C. Range 5: 0 to 16.0 W.C. Range 6: 0 to 50.0 W.C. Standard Ranges have a turndown of 10:1. Compound ranges available. Consult factory. Example: Range 1 Maximum Range = 0 to 0.10 W.C., Minimum Range = 0 to 0.01 W.C. (Turndown of 10:1) Output Signals: Analog: 4-20 ma signal (Max. Loop resistance = VDC) is user programmable to Differential Pressure (Inches of Water Column) or Flow (SCFM, ACFM or LB/Hr). External inputs or programmed constants for temperature and absolute pressure are necessary for a true flow measurement. Digital: Two (2) optional digital (open collector) outputs available. Activation programmable by end user. Availability pending. Communications: Alarm Display: Power Supply Required: Reverse Polarity Protection: Turn On Time: Temperature Limits: Overpressure Limits: Damping: Humidity Limits: Inputs: Optional digital HART Communications module Availability pending. Programmable HI/LO Limit Alarm. High Contrast, 2 line, alphanumeric LCD with -20 o to 150 o F (-28 to 66 o C) operating temperature. 24 to 40 VDC loop power, minimum 10.5 volts required at inputs. Yes 4 seconds (maximum). Operating: -40 to 150 o F (-40 to 66 o C) Storage: -40 to 180 o F (-40 to 82 o C) Proof Pressure: 10 PSID Burst Pressure: 50 PSID Maximum Line Pressure: 50 PSIG Standard Time Constant: 500 msec. Additional damping adjustable via integral keypad from 0.5 to 5 Seconds in 0.5 second increments. 100% Non-condensing, (MST2400 Only). Standard: Non-isolated, 4 wire RTD input connection. Optional 4-20mA Isolated Inputs: Input ranges are software rangeable. External Temperature: 4-20mA Input. External Absolute Pressure: 4-20 ma Input External DP: 4-20mA Input Optional Digital Input: One optional digital (TTL level) input is available. Availability pending. PERFORMANCE SPECIFICATIONS Accuracy: Stability: Ambient Temperature: Mounting Position Effect: For spans from 40% to 100% of maximum range 1:1 to 2.5:1 then accuracy = 0.15% of Re-ranged Span. For spans from 20% to 39% of maximum range 2.5:1 to 5:1 then accuracy = ( TD) of Re-ranged Span. For spans from 10% to 19% of maximum range 5:1 to 10:1 then accuracy = ( TD) of Re-ranged Span. TD = Maximum Range / Re-ranged Span 0.1% of Maximum Range / 12 Months Zero: No Effect Span: Less than 0.001% of Re-ranged Span per Deg F. Corrected by internal temperature sensor. Minor effect on Zero. Corrected by setup parameters. Vibration Effect: Less than 0.2% of Maximum Range / g, Hz. PHYSICAL SPECIFICATIONS: Enclosure Types: Process Connections: Electrical Connections: Weight: Company MST2100: NEMA 1, Anodized Aluminum. MST2400: NEMA 4X, Fiberglass. MST2100: 1 / 8 NPTF MST2400: 1 / 4 NPTF Stainless Steel MST2100 & MST2400: Cage Clamp style terminal block AWG wire size. MST2400: 1 / 2 Liquid-Tight flexible conduit connections. MST2100: 2.5 lbs. (1.14 kg) MST2400: 8.0 lbs (3.63 kg) For over 20 years, Thermo Electron has been the recognized leader in the measurement of air/gas flow and very low differential pressure in industrial applications. Thermo offers a complete line of pitot/static probes and arrays, D.P. Transmitters, the unique Nozzle Pitot Flow Sensor, turbine flowmeters, the 4400 Alarm Monitor and a complete family of Current to Pressure (I/P), Voltage to Pressure (E/P) and Pressure to Current (P/I) Transducers. Contact Thermo Electron, Therm's Representative, or visit our website for further information, specifications and applications assistance. Let us point you in the right direction. Thermo Electron Corporation P.O. Box 1190, 3333 Airpark Road Fuquay, North Carolina U.S.A. Telephone: (919) Facsimile: (919) Represented By: NATIONAL ACCREDITATION OF CERTIFICATION BODIES SIRA CERTIFICATION SERVICE SUPPLIER QUALITY MANAGEMENT CERTIFICATE NO ISO 9001 MD , March 2000 All specifications subject to change without notice. HART is a registered trademark of the HART Communications Foundation. All other trademarks acknowledged.
PS-AULDP Series. Overview. Applications. Features & Benefits. Datasheet. Ultra Low Air Differential Pressure Transmitters
PS-AULDP Series Datasheet Ultra Low Air Differential Pressure Transmitters Overview The PS-AULDP Series are ultra-low-pressure transmitters. These devices can be used to measure differential pressure between
More informationTable of Contents. General Information. Document Sure-Aire Flow Monitoring System. User and Service Manual WARNING CAUTION
Document 476092 User and Service Manual Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install,
More informationTPE 1464 Series Pressure Transducer
TPE 1464 Series Pressure Transducer Description The KMC TPE 1464 series of pressure transducers incorporate a gauge pressure transmitter featuring low hysteresis, excellent repeatability, and longterm
More informationExplosion-Proof Gauge Pressure Transmitter
Technology Solutions T EK-B AR 3120A Explosion-Proof Gauge Pressure Transmitter PRESSURE www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction The Tek-Bar
More informationLAKEWOOD INSTRUMENTS MODEL 1575e WATER TREATMENT CONTROLLER
LAKEWOOD INSTRUMENTS MODEL 1575e WATER TREATMENT CONTROLLER The Model 1575e uses the latest in microprocessor capability, giving the user a high level of application flexibility. A large illuminated graphics
More informationHTZ. Description. Features. Smart HART Humidity and Temperature Transmitter
March 2018 Description The HTZ Smart HART Transmitter simultaneously measures humidity and temperature in industrial, commercial, manufacturing, and HVAC applications. Based on the humidity and temperature
More informationHMT330 Series Humidity and Temperature Transmitters for Industrial Applications
HMT330 Series Humidity and Temperature Transmitters for Industrial Applications The HMT330 transmitter family has the solution for demanding industrial humidity measurements. Six models for demanding industrial
More informationSono-Trak Transit Time Clamp-on Ultrasonic Flow Meter
A trademark of Spirax Sarco, Inc. Sono-Trak Transit Time Clamp-on Ultrasonic Flow Meter Description Engineered for performance excellence, the Sono-Trak Transit Time ultrasonic meter combines non-invasive,
More informationZone Pressure Touch (ZPT) Sensor with Attached Tube (-AT) - Low Pressure Range Unit Installation and Operation Instructions
Product Identification BAPI s Touch Low Range Pressure Sensor with Attached Static Pressure Probe is an accurate, rugged and economical solution for measuring and reporting duct/building static pressure,
More informationLevel-Lance Model 5400A
Sales Manual Section 100 PRODUCT SPECIFICATION 5400A GENERAL DESCRIPTION The ROBERTSHAW Level-Lance Model 5400A is a microprocessor based, multi-point On-Off capacitance type level detection system. Utilizing
More informationDigitalFlow GC868 Panametrics Clamp-On Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features
Applications The DigitalFlow GC868 clamp-on gas flowmeter is a complete ultrasonic flow metering system for measurement of most gases, including: Natural gas Compressed air Fuel gases Erosive gases Corrosive
More informationZone Pressure Touch Sensor - Standard Range
Overview The Zone Pressure Touch (ZPT) Sensor is an accurate, rugged and economical solution for measuring and reporting duct/ building static pressure, room-to-room differential pressure or air velocities/volumes.
More informationJT400 Multivariable Transmitter
Product Specification Sheet JT400 Multivariable Transmitter Wireless Ultra Low Power Platform with Integrated, Chart Replacement Data Logging and I/O The industry s first, ultra-low power, multivariable
More informationMicroTrans EQ Signal Processor. Operation & Maintenance Manual
MicroTrans EQ Signal Processor Operation & Maintenance Manual Engineered for accuracy, applicability, durability and simplicity in HVAC air systems and industrial process control loops TABLE OF CONTENTS
More informationZone Pressure Touch (ZPT) Sensor - Standard Range
Product Identification BAPI s Touch Pressure Sensor is an accurate, rugged and economical solution for measuring and reporting duct/ building static pressure, room-to-room differential pressure or air
More informationFamily of Water Cut Analyzers
Phase Dynamics Technology for Precision Measurements Phase Dynamics, Inc. 1251 Columbia Drive Richardson, TX 75081 USA E-Mail sales@phasedynamics.com Tel: 972-680-1550 Fax: 972-680-3262 Family of Water
More informationTABLE OF CONTENTS INTRODUCTION. 3. Analog Input Analog Output Digital Input Digital Output OPERATIONAL DESCRIPITON.. 7 PROGRAMMING AND INITIAL SETUP.
DIVERSIFIED HEAT TRANSFER SERIES 700 STEAM GENERATOR CONTROLLER INSTRUCTION MANUAL VISIT OUR WEBSITE AT SIGMACONTROLS.COM SERIES 700 DHT STEAM GENERATOR MANUAL 042514 2 TABLE OF CONTENTS INTRODUCTION.
More informationConductivity Transmitters
Conductivity Transmitters CDTX-90 Series Starts at $ 576 Electronics Only Display in µs, ms, kω, MΩ, ppm (TDS) Simulate Function Programmable Temperature Compensation Relay Options Dual Output Option Allows
More informationaccurate measurement of compressed air consumption and leakage detection Calibration certificates and continous calibration, OEKD calibration service
Series Flowmeter for compressed air and gases in Industrial Applications The flowmeter of the series, based on the measurement principle of thermal mass flow, is ideally suited for the measurement of flow
More informationFlow Meters. Model B Flow Monitor. Model B2800. Flow Monitor
Flow Monitor Model B2800 Flow Meters Model B2800 Flow Monitor Microprocessor-based flow monitor and totalizer Use with Blancett turbine flow meters as well as other flow meters with a frequency output
More informationEE771 Series. Flowmeter for compressed air and gases in Industrial Applications. EE771 Compact. EE771 remote probe
Series Flowmeter for compressed air and gases in Industrial Applications The flowmeter of the series, based on the measurement principle of thermal mass flow, is ideally suited for the measurement of flow
More informationCALIBRATORS. BetaGauge II INTRINSICALLY SAFE MODEL AVAILABLE
CALIBRATORS BetaGauge II INTRINSICALLY SAFE MODEL AVAILABLE BetaGauge II. The new industry standard in portable pressure calibrators is 0.025% accuracy. The process industries are quite literally under
More informationInstallation and Operating Manual FM50 IOM 2-18 DRAFT
Installation and Operating Manual Table of Contents 1. Safety Precautions... 3 2. Details 2.1 Part Numbers... 4 2.2 Configurations... 5 2.3 Specifications... 13 2.4 Cables and Wiring... 14 2.5 Interface,
More informationTRANSMISSOR DE PRESSÃO PIEZO RESISTIVO INTELIGENTE MICRO PROGRAMÁVEL SÉRIE PAS
TRANSMISSOR DE PRESSÃO PIEZO RESISTIVO INTELIGENTE MICRO PROGRAMÁVEL SÉRIE PAS Flexibility Data configuration with HART configurator Measuring of gauge and absolute pressure Reliability Continuous self-diagnostic
More informationAnalyzer/Controller. ph/orp HART. Model 54e ph/orp ESSENTIAL INSTRUCTIONS WARNINGS RISK OF ELECTRICAL SHOCK
Instruction Sheet PN 51A-54epH/rev J October 2010 ph/orp HART Model 54e ph/orp Analyzer/Controller For additional information, please visit our website at www.emersonprocess.com/raihome/liquid/. ESSENTIAL
More informationUltrasonic Flow Meter Brochure
Ultrasonic Meter Brochure Rev. 2011/06/10 www.sitelab.us.com Descriptions SL1168 Ultrasonic meter uses the latest digital technology and low-voltage broadband pulse transmission. The instrument is tolerant
More informationSpecifications - Installation and Operating Instructions. Duracell is a registered trademark of The Gillette Company.
Bulletin P-DM-1100 Series DM-1000 DigiMag Digital Differential Pressure Gage Specifications - Installation and Operating Instructions The Series DM-1000 DigiMag Digital Differential Pressure Gage is the
More informationModel 332 Differential Pressure Transmitter
Model Differential Pressure Transmitter USERS GUIDE Please read carefully before using. Manufactured by: FURNESS CONTROLS LIMITED Beeching Road, Bexhill, East Sussex, TN9 LJ, England. Telephone (044) 706
More informationDCT7088 Portable Digital Correlation Transit Time Flowmeter
DCT7088 Portable Digital Correlation Transit Time Flowmeter DCT7088 Portable Digital Correlation Transit Time Flowmeter Applications HVAC Potable water Ultrapure liquids De-ionized water Petroleum products
More informationMulti-range pressure and differential pressure transmitter
Page 1/6 Multi-range pressure and differential pressure transmitter Type 402005 Applications Ventilation Air conditioning Clean-room technology Flue draft mechanisms Filter monitoring Brief description
More informationDifferential Liquid/Gas Pressure Transmitter
Installation Instruction Differential Liquid/Gas Pressure Transmitter Catalog Number(s) 1414-CPZ10FWFAA, 1414-IPZ10FWFAA Explosion Hazard WARNING Do not use in an explosive or hazardous environment, with
More informationK10 Intrinsically Safe Electro-Pneumatic Positioner Operating Manual
K0 Intrinsically Safe Electro-Pneumatic Positioner Operating Manual Pneumatic Connection Single Acting Actuator (Spring Return): For single acting actuators Outlet Port 2 is to be plugged. Outlet Port
More informationMTII4200 Level Transmitter Installation, Operation & Maintenance Instructions
Specialists in Liquid Level Indication MTII4200 Level Transmitter Installation, Operation & Maintenance Instructions Section: M500 Bulletin: M500.31 Date: 05-17-16 Supersedes: 09-30-11 1. INTRODUCTION
More informationInc. FLO-CAL Liquid Calibration System FLO-CAL SOFTWARE FLEXIBLE DESIGN TO MEET YOUR LIQUID FLOW CALIBRATION REQUIREMENTS
FLEXIBLE DESIGN TO MEET YOUR LIQUID FLOW CALIBRATION REQUIREMENTS FLO-CAL A portable Liquid Flow Standard FLO-CAL INSTRUMENT Data acquisition and interface tool with flow meter frequency and analog signals.
More informationLineGuard Specification Sheet Issued 8/24/10 VA Revision 0. Valve Automation
LineGuard 2300 The LineGuard 2300 Electronic linebreak detection system monitors natural gas pipeline pressure and rate of pressure drop, and can provide manual or automatic control of a single valve actuator
More informationPLEASE READ INSTRUCTIONS CAREFULLY BEFORE INSTALLATION!
TUC2 / TUCH2 Model Series Installation Instructions PLEASE READ INSTRUCTIONS CAREFULLY BEFORE INSTALLATION! APPLICATION The TUC2 provides temperature space monitoring with a backlit LCD. The TUCH2 provides
More informationModel Sono-Trak General Specification
Model General Specification Features! High accuracy! Simple, non-invasive clamp-on installation! No moving parts! No pressure drop! Bidirectional measurement! Low maintenance! Submersible sensors! Automatic
More informationC100 Portable Multifunction
C100 Portable Multifunction Superior Accuracy as compared to Competitors! Wahl C100 Simultaneous Measurement and Generation Rugged IP54 Construction for On Site Use Quick Connect Terminals Measurement
More informationFlow Measurement SITRANS F US Clamp-on
Overview SITRANS FUG1010 clamp-on non-intrusive ultrasonic flow transmitter is ideal for natural and process gas applications, including checkmetering, allocation, production, storage and gas fired power
More informationEPWR Series. RoHS. Product Description. Available Products. Installation Instructions 01
01 Series RoHS Compliant Product Description The Series remote pressure transducers are designed for differential pressure applications. The sensors are remotely installed on existing plumbing runs. The
More informationDP DP2500 DP0250
DP7000 - DP2500 DP0250 PB_DP7000_DP2500 - DP0250_07 2016 Field adjustable, multi-range differential pressure transmitters Product Bulletin The Delta Pressure transmitter series of Johnson Controls, with
More informationTOXALERT MODEL AIR 2000
TOXALERT MODEL AIR 2000 NOTE: Toxalert s Model GVU-CO 2 Sensor is the same as the Air2000R. Microprocessor-based, Infrared Environmental CO 2 Sensor OPERATOR S MANUAL TOXALERT TM INTERNATIONAL INC. P.O.
More informationTrident and Trident X2 Digital Process and Temperature Panel Meter
Sign In New User ISO 9001:2008 Certified Quality System Home Products Online Tools Videos Downloads About Us Store Contact Policies Trident and Trident X2 Digital Process and Temperature Panel Meter Products
More informationResolution 1 F (1 C) single point; degrees C or Calibration single or dual point Calibration F
RMS Rainwater Harvesting Series 100 Controller Specifications Measurement Performance Contacting Conductivity ph Range 0-10,000 µs/cm Range -2 to 16 ph units Resolution 1 µs/cm Resolution 0.01 ph units
More informationDMT340 Series Dewpoint and Temperature Transmitters for Very Dry Conditions
www.vaisala.com DMT340 Series Dewpoint and Temperature Transmitters for Very Dry Conditions The display shows measurement trends, real-time data, and measurement history. Features/Benefits Measures dew
More informationSITRANS F flowmeters SITRANS F US
SITRANS F flowmeters Siemens AG 2008 Overview Application SITRANS FUG1010 is ideal for most natural and process gas industry applications, including: Checkmetering Allocation Flow survey verification Lost
More informationCDD4 Duct Carbon Dioxide Transmitter
Drill or punch a 1-1/8 or 1-1/4 hole in the duct at the preferred location and insert the probe into the hole to mark the enclosure mounting holes. Remove the unit and drill the four mounting holes. Clean
More informationCDD Carbon Dioxide Transmitter
Introduction The OSA CO2 transmitter uses Infrared Technology to monitor CO2 levels within a range of 0 2000 ppm and outputs a linear 4-20 ma or 0-5/0-10 Vdc signal. The enclosure is designed to operate
More informationModel HU-224/225. Technical Information TI.224/ Humidity Transduce r FOR ADDITIONAL INFORMATION SEE HU-224/225 DATA SHEET
Model /225 FOR ADDITIONAL INFORMATION SEE /225 DATA SHEET SPECIFICATIONS Accuracy*: ± 2% / ± 3% RH Range: 0-100% RH Hysteresis: ± 1% Supply Voltage:12-40 VDC 12-35 VAC (VDC output units only) Supply Current:
More informationProduct Data. Model 675 Shark Cage Submersible Level Transmitter ELECTRONIC PRESSURE MEASUREMENT PRODUCTS DESCRIPTION FEATURES APPLICATIONS
EPMP - 1 DESCRIPTION The Model 675 is specifically designed for slurry and highly viscous applications where clogging of the sensor area is common. The Model 675 uses a 3.5" flush diaphragm to prevent
More informationDMT PERFORMING UNDER PRESSURE DMT. All-Media Pressure Scanner Features. Applications. Description 1/8
Features Low Pass Anti-aliasing Filter per Channel Up to ±0.05% System Accuracy EU Throughput Rates in excess of 100 Hz 10 BaseT Ethernet Interface, TCP & UDP Protocol Pressure Ranges from 5 psi (34 kpa)
More informationControl IT Booster Pump Controller
Data Sheet SS/_4 Control IT Booster Pump Controller Protection for the pasteurization process ensuring a high quality, safe product for your customers High visibility LED displays continuous indication
More informationFlow Meters. Model B Flow Monitor. Model B2800. Flow Monitor
Flow Monitor Model B2800 Flow Meters Model B2800 Flow Monitor Microprocessor-based flow monitor and totalizer Use with Blancett turbine flow meters as well as other flow meters with a frequency output
More informationSeries DMHF Heat Meter
Series DMHF Heat Meter The Series DMHF adopt the MultiPulse TM Technology, Digital Signal Processing Technology and Error Correction Technology, which are the state-of-the-art non-invasive flow measurement
More informationMIST Version 2.0 USER S GUIDE. Preliminary Version. INTRODUCTION...2 General Description...2 Models Available...2
1 MIST Version 2.0 USER S GUIDE Preliminary Version INTRODUCTION...2 General Description...2 Models Available...2 INSTALLATION...2 Unpacking...2 Mechanical Installation...3 Electrical Wiring...3 Stand-alone
More informationLS 6600 Technical Datasheet
Technical Datasheet Switch for level detection and dry-run protection Optimised sensor geometry, easy to clean Measures products with dielectric constant > 1.5 Small and compact KROHNE 06/2011-4001367301
More informationHumidity goes Digital
Humidity goes Digital Networkable Industrial Transmitter Humidity, Temperature and Dew Point or other Computed Parameter Optional metal enclosure Unique HygroClip technology for superior performance Durable,
More informationDPC DPC PRECISION DIGITAL MASS FLOW CONTROLLER WITH MULTI-GAS FUNCTIONALITY
43 Design Features Simultaneously displays Mass Flow, Volumetric Flow, Pressure and Temperature. Multi-Gas functionality: support for 90 different gases and gas mixes. User Defined Mixture functionality
More informationZFM ZFM DIGITAL MASS FLOW METER
BULLETIN EM20180402 25 BULLETIN EM20180402 Design Features n Multi-gas/Multi-range functionality up to 8 bar (currently for 6 gases). n Full scale covered flow ranges from 3.125 sml/min to 10 sl/min are
More informationModel 675 DREXELBROOK. Shark Cage Submersible Level Transmitter DATA SHEET. Description. Features. Applications.
DREXELBROOK DATA SHEET Model 675 Shark Cage Model 675 Shark Cage with 3.5" flush diaphragm pressure via its sensing element, an ion implanted silicon semiconductor chip with integral Wheatstone Bridge
More informationPrecision humidity/temperature control/sensing
HIGH ACCURACY HUMIDITY/TEMPERATURE TRANSMITTER HAHT Series Precision humidity/temperature control/sensing FEATURES: Highly stable RH sensor element Humidity range: 0-100% Accuracy available 1% & 2% High
More information200CRS Single-Channel Conductivity/Resistivity Measurement System THORNTON. Leading Pure Water Analytics
THORNTON Leading Pure Water Analytics - NIST Traceable Calibration - Two Analog Outputs Standard - Three-Wire Temperature Measurement - Wide Range of Sensor and Cable Selections 200CRS Single-Channel Conductivity/Resistivity
More informationMID approval no. DE-08-MI004-PTB004 Date of release
1. Identification Energy and Flow Computer Flow rate and energy calculator for liquids, gases and water steam E-DB-1000-700-01 MID approval no. DE-08-MI004-PTB004 Date of release 04.01.08 2. Area of Application
More informationPDW30 Point-To-Point Wireless Bridge
PDW30 Point-To-Point Wireless Bridge WIRELESS WIreless System FEATURES Wire Replacement in a Rugged, Industrial Housing Inputs and Outputs on Both Field Units Simple to Order, Configure, & Install 1 Mile
More informationSeries TFXD FIXED LOCATION TRANSIT TIME FLOW METER FEATURES
FIXED LOCATION TRANSIT TIME FLOW METER Transit Time Flow Meters feature the world s most advanced non-invasive flow measurement technology available providing a measuring system with superior accuracy,
More informationMICRO SERIES PROCESS DISPLAYS LARGE DIGIT MODELS
The MICRO SERIES PROCESS DISPLAYS LARGE DIGIT MODELS Mighty-5 DPM MODELS Micro-P & Mighty-1 Mighty-1 Micro-P ELECTRO-NUMERICS, INC. Introduction The Electro-Numerics family of Digital Panel Meters and
More informationNFC110. Flow Computer For Low Pulses FEATURES
Flow Computer For Low Pulses FEATURES l STABLE READING WITH PULSES DOWN TO ONE PULSE EVERY 5 MINUTES l PULSE FLOW INPUT UP TO 100 Hz, CAN POWER THE SENSOR l WORKS WITH OPTO-COUPLER FLOW METERS l SEVEN
More informationPROJECT: SPECIFIER: TYPE: QTY: OUTPUT LEVEL: COLOR: LENGTH X WIDTH: MOUNTING: DIMMING/CONTROLS:
PROJECT: SPECIFIER: TYPE: QTY: Available in 5 output levels of Static White at 24 Volts RGB and RGBW available at 24 Volts Tunable White and Double Sided available Great for creating Luminous Ceilings
More informationSeries ULT Ultrasonic Level Transmitter
Bulletin L-45 Series ULT Ultrasonic Level Transmitter Specifications - Installation and Operating Instructions 3 29/32 [99.21] 4 9/32 [108.74] 2X 1/2 NPT ø3 21/64 [84.53] 8 1/16 [204.79] Series ULT Ultrasonic
More information100mm Process Indicator Recorder
Data Sheet SS/_3 100mm Process Indicator Recorder One or two pen continuous line 100mm recorder universal input for thermocouple, RTD, mv, ma and V Clear, 5-digit LED display high visibility, wide viewing
More informationPressure transmitter for highest pressure applications Up to 217,500 psi (15,000 bar) Model HP-2
Electronic pressure measurement Pressure transmitter for highest pressure applications Up to 217,500 psi (15,000 bar) Model HP-2 WIKA data sheet PE 81.53 Applications Test bench construction Water jet
More informationETHERNET INTELLIGENT PRESSURE SCANNER
ETHERNET INTELLIGENT PRESSURE SCANNER The Model 9216 pneumatic intelligent pressure scanner is a completely selfcontained high performance pressure acquisition module for multiple measurements of dry,
More informationGFC114. Low Power Flow Computer FEATURES
Low Power Flow Computer FEATURES l UNIVERSAL INPUT, 5 khz, CAN POWER THE l SIMPLIFIED MENUS AND PROGRAMMING l NO NEED OF AMPLIFIERS OR LINEARIZERS l SEVEN DIGIT RATE WITH PROGRAMMABLE DECIMAL PLACES l
More informationUltrasonic Heat Flow Meters
APPLICATIONS Measuring heat flow Sewage and drainage water with small particle quantity Beverage and food processors HVAC hot and cool water Water and waste treatment Power plants, heat energy boiler feed
More informationMicro Motion Model 2200S 2-Wire Transmitter with MVD Technology
Product Data Sheet PS-001094, Rev. C September 2009 Micro Motion Model 2200S 2-Wire Transmitter with MVD Technology The Micro Motion Model 2200S 2-wire transmitter enables the use of reliable and accurate
More informationDigital Indicator Solutions
Digital Indicator Solutions Loop-Powered Attachable Compact Attachable Loop-Powered Smart Compact System Loop-Powered Compact Smart System Intelligent Smart System "Intelligent" Options Dual & Display
More informationScanner 2000 Steam Mass Flow Transmitter
3352051/2 IM-P335-24 MI Issue 2 Scanner 2000 Steam Mass Flow Transmitter Installation and Maintenance Instructions 1. Safety information 2. Mechanical installation 3. Configuring software 4. Wiring procedures
More information350 SMART MANOMETER OPERATING INSTRUCTIONS
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com 350 SMART MANOMETER OPERATING INSTRUCTIONS Meriam Instrument s 350 Smart Manometer
More informationDWYER INSTRUMENTS, INC. Series AVUL Air Velocity Transmitter. Specifications - Installation and Operating Instructions.
Series AVUL Air Velocity Transmitter Specifications - Installation and Operating Instructions Bulletin P-AVUL 3-49/64 [95.71] 2-43/64 [67.92] 1/2 NPS 3-3/16 [80.81] 1-19/32 [40.59] 31/32 24.58 3-33/64
More informationGeneral Specifications
General Specifications -A Yokogawa Y-Flow YFFC Orifice Flow Computer Overview Yokogawa s low power orifice flow computer offers flexible I/O points and superior data collection with a wide range of connectivity
More informationInsertion Flowmeter for compressed air and gases DN50 - DN700 (2-28 )
The flow meter is based on the thermal mass flow measurement and is ideal for measuring the flow of compressed air and gases in pipes from DN50 (2 ) to DN700 (28 ). With the, the consumption of compressed
More informationERNG-X. Description. Applications. ERNG-X Specifications DERNG2108X012
ERNG-X DERNG2108X012 Description The ERNG-X is a steady state no bleed engineered system for accurate and reliable control of Natural Gas. The ERNG-X includes a pressure regulator, preconditioning filters,
More information12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)
4-20 ma & Relay Output Features 4-20 ma, ± 10 V, TC & RTD Inputs 12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm) 24 VDC @ 200 ma Transmitter Power Supply Options Type
More informationSTT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25H, STT25S, STT25M, STT25D EN0I-6031 March 2010
STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25H, STT25S, STT25M, STT25D EN0I-6031 March 2010 Introduction Honeywell s STT 3000 family of microprocessor based smart temperature
More informationSelf-Powered Wireless Instrumentation
Self-Powered Wireless Instrumentation Accutech Rapid deploy wireless instrumentation solutions for telemetry and remote SCADA Cost-Effective Solutions for Challenging Applications 03 Knowledge of your
More informationBA/BS4S Temperature Sensor Installation & Operating Instructions
Product Overview and Identification The BAPI-Stat 4 room temperature sensor features a large format LCD and slider setpoint adjustment. Additional options include button override and communication jack.
More informationVPINSTRUMENTS.COM VPFLOWSCOPE M. Your next step in gas flow measurement
VPINSTRUMENTS.COM VPFLOWSCOPE M Your next step in gas flow measurement The Internet of Things / industry 4.0 is rapidly transforming our world. Production becomes smart, intelligent and autonomous. Production
More informationNOW A PRODUCT! 1/4 DIN Auto/Manual Station. The Interface Solution Experts. The Interface Solution Experts. PS532 V6 March 2017
NOW A 5 3 2 The Interface Solution Experts PRODUCT! 5 3 2 1/4 DIN Auto/Manual Station The Interface Solution Experts PS532 V6 March 2017 GENERAL DESCRIPTION The 532 Auto/Manual Station ensures the integrity
More informationSHPFI Smart Frequency to Current Converter & Pulse Scaler Installation and Operating Instructions
SHPFI Smart Frequency to Current Converter & Pulse Scaler Installation and Operating Instructions http://www.kep.com KESSLER-ELLIS PRODUCTS 10 Industrial Way East Eatontown, NJ 07724 800-631-2165 732-935-1320
More informationHow to build a Conductivity Measurement System
How to build a Measurement System F B E C D A A Immersion system in open basin B Flow-through system C 1/2 pipe mounted system D 3/4 pipe mounted system E Side-entry system in vessel F Top-entry system
More informationRHE21. Exd / Exd(e) Extreme Environment Multifunction Coriolis Flow Transmitter
RHE21 Exd / Exd(e) Extreme Environment Multifunction Coriolis Flow Transmitter Features Wall or Pipe Bracket Mounting Corrosion resistant housing in SS316 available Selectable Units for Mass, Volume, Density
More informationInstallation and Maintenance Instructions for GC55 Differential Pressure Transducer Version 1.0 5/11
Installation and Maintenance Instructions for GC55 Differential Pressure Transducer Version 1.0 5/11 2011 Ashcroft Inc. 250 East Main Street, Stratford, CT 06614 USA Tel: 203-378-8281, Fax: 203-385-0402
More informationEchotouch, EchoSpan & EchoSwitch Ultrasonic Liquid
Echotouch, EchoSpan & EchoSwitch Ultrasonic Liquid The Echotouch, EchoSpan and EchoSwitch are innovative ultrasonic liquid level sensor families that replace float, conductance and pressure sensors that
More informationDPM DPM MULTI PARAMETER - MULTI GAS MASS FLOW METER
MULTI PARAMETER - MULTI GAS MASS FLOW METER 1 MULTI PARAMETER - MULTI GAS MASS FLOW METER Design Features Multi-Parameter functionality: Mass Flow, Volumetric Flow, Gas Pressure and Temperature. Multi-Gas
More informationRosemount 1595 Conditioning Orifice Plate
Product Data Sheet Rosemount 1595 Rosemount 1595 Conditioning Orifice Plate Designed to provide superior performance in short straight pipe run applications Requires only two diameters of straight pipe
More informationHIGH-VOLTAGE DC METER
HIGH-VOLTAGE DC METER Javelin D PD644 0-300 VDC input NEMA 4X, IP65 front Scale in engineering units Sunlight readable LED display 4-20 ma analog output Two form C 3 A relays option RS-485 serial communications
More informationVVP10-H HART VALVE POSITIONER. Great Performance, Compact, Robust in Severe Conditions* HART 7 Communication Protocol. Electronic Coil Technology
VVP10-H HART VALVE POSITIONER Great Performance, Compact, Robust in Severe Conditions* HART 7 Communication Protocol Electronic Coil Technology Non-Contact Position Sensor (Hall Sensor) 4-20 ma NAMUR NE
More informationRHE16. Compact Multifunction Coriolis Flow Meter Transmitter. Features. Applications. Benefits
RHE16 Compact Multifunction Coriolis Flow Meter Transmitter Features Extremely compact footprint ideal for embedding into small systems and machines Mount remotely or in compact form Low installation cost
More informationSafety. 1. Installation 1.1 CR:Services 1.2 Driver Card Installation 1.3 Sensor Types 1.4 Sensor Wiring
Safety 1. Installation 1.1 CR:Services 1.2 Driver Card Installation 1.3 Sensor Types 1.4 Sensor Wiring 2. Configuration - Operation 2.1 Setup-Calibration 2.2 Diagnostics 3. Specifications Safety 100mV
More informationDREXELBROOK. Datasheet Universal IV In-Line Water Cut Meter. with Spool Piece Mounting USE THE BEST APPLICATIONS. Eliminate Routine Maintenance
USE THE BEST For over 50 years, Drexelbrook has been the world s leader in capacitive based measurements by providing reliable and accurate products at a reasonable cost. We offer the highest pressure