IT monitoring. CMC III Monitoring system CMC III system representation CMC III system overview CMC III Processing Unit/Compact...

Size: px
Start display at page:

Download "IT monitoring. CMC III Monitoring system CMC III system representation CMC III system overview CMC III Processing Unit/Compact..."

Transcription

1 IT monitoring Monitoring system system representation system overview Processing Unit/Compact sensors/accessories control units/ sensors...45 Interface for CMC II sensors...45 Access System Interface for PSM, PCU PSM and slave PDU for direct connection...45 accessories Power supply unit Programming cable CAN bus connection cable Connection cable/extension Extension cable RJ Mounting unit, U Mounting unit Door control system Door control system Door control module Door kit Door comfort handle Door switch Monitor/keyboard unit Monitor/keyboard unit, U...46 KVM switch...46 Dynamic Rack Control RFID aerial RFID tags RFID controller CAN bus DRC Management software RiZone...46 Server shutdown software...46 Your benefits A better overview of your IT infrastructure Enhanced security Automated processes Exceptional cost efficiency High energy savings Simple project management Fast installation Flexible, individual solutions with standard products from Rittal High standard of quality with coordinated standard products Sample applications, see page 449 Liquid Cooling Package LCP, see page 428 Monitor/keyboard unit, see page 46 Electric comfort handle TS 8, see page 564 Rittal Catalogue 4/IT infrastructure 445

2 Monitoring system Computer Multi Control (CMC) is an alarm system for network and server enclosures, cases, containers and rooms. It monitors temperatures, humidity, access, smoke, energy and many other physical ambient parameters. It is a modular system that can be flexibly adapted to meet the customer's specific monitoring requirements. User benefits plus exceptional savings are achieved, thanks to monitoring via the network and the automation of security processes. Further information can be found at: 2 Processing Unit Rittal Catalogue 4/IT infrastructure

3 5 6 Processing Unit, see page 449 Power supply Redundant power supply I/O unit power unit PSM measuring bar for direct connection Up to 6 CAN bus systems may be connected vandalism sensor temperature sensor CAN bus sensor for connection of CMC II sensors CAN bus access Up to 6 CAN bus systems may be connected Rittal Catalogue 4/IT infrastructure 447

4 + Processing Unit Compact System overview Up to 4 CAN bus components are supported ) sensors for direct connection Mini USB: Programming cable is required for programming, see page 457 Internal infrared access sensor 0 CAN bus CAN bus sensor as adaptor for CMC II sensors Processing Unit Compact Voltage supply 24 V (DC) and Redundant voltage supply 24 V (DC) Power packs, see page 457 CAN bus access with integral IR access sensor Alarm relay output: Changeover contact for safety extra-low voltage Ethernet 0/00 BaseT RJ 45 with PoE: Ethernet interface to IEEE 802. Over 0/00 BaseT full duplex 0/00 Mbit/s RJ 2/RS22 accessory modules: Display unit, ISDN unit, GSM unit External temperature sensor (included in the supply of C) Two integral digital inputs CAN bus unit Note: Server shutdown software for is required to shut down the server, see page V (DC) 2) Interfaces unit for connecting CMC II accessories Connection for other products, see page 452 2) External 24 V (DC) supply via required ) Depending on power supply/ connection combinations, see page 45 CAN bus unit Rittal Catalogue 4/IT infrastructure

5 + Processing Unit System overview CAN bus sensors for direct connection Mini USB: Programming cable is required for programming, see page Internal infrared access sensor CAN bus sensor as adaptor for CMC II sensors CAN bus 2 SD card insert: for data logging Processing Unit CAN bus access with integral IR access sensor Voltage supply 24 V (DC) and redundant voltage supply 24 V (DC) Power packs, see page 457 Alarm relay output: Changeover contact for safety extra-low voltage Ethernet 0/00 BaseT RJ 45 with PoE: Ethernet interface to IEEE 802. via 0/00 BaseT full duplex 0/00 Mbit/s RJ 2/RS22 accessory modules: Display unit, ISDN unit, GSM unit Up to 6 CAN bus systems are supported ) External temperature sensor (included in the supply of ) USB master for data logging and update ) Depending on power supply/connection combinations, see page 45 Two integral digital inputs Up to 6 CAN bus systems are supported ) Control units CAN bus unit I/O unit power unit 2 24 V (DC) 2) Contains 8 digital inputs 2 and 4 relay outputs Functions: Switching and measuring voltage, current, power and work With two outputs Also for the activation of fans Interfaces unit for connecting CMC II accessories Connection for other products, see page 452 2) External 24 V (DC) supply via required I/O unit Power unit CAN bus unit Rittal Catalogue 4/IT infrastructure 449

6 Processing Unit/Compact System overview Page 448/449 Basic modules and connection accessories Page 45 Redundant voltage supply, plus Power over Ethernet (PoE) Simple wiring with CAN bus connection system (RJ 45) Connection to control roomsystems via OPC UA Material: Plastic Surface finish: Front: Smooth Enclosure: Textured Colour: Front: RAL 9005 Enclosure: RAL 705 Protection category IP to IEC : IP 0 Supply includes: Basic system Quick-start instructions 4 mounting feet Approvals: culus Photo shows a configuration example with equipment not included in the scope of supply Processing Unit Processing Unit Compact W x H x D mm 8 x 40 ( U) x (front assembly) 8 x 40 ( U) x (front assembly) Operating temperature range 0 C +45 C 0 C +45 C Operating humidity range 5 95 % relative humidity, non-condensing 5 95 % relative humidity, non-condensing Sensors/CAN bus connection units max. 2 max. 4 Max. overall cable length for CAN bus 2 x 50 m x 50 m Interfaces Inputs and outputs Operation/ signals Protocols Redundant power supply Functions Integral sensors Network interface (RJ 45) Ethernet to IEEE 802. via 0/00BaseT with PoE Ethernet to IEEE 802. via 0/00BaseT with PoE Front USB interface Mini USB for system setting Mini USB for system setting Rear USB interface For USB stick for data records and SW updates up to 2 GB Front SD-HC slot x up to 2 GB for data recording Rear serial RS22 (RJ 2) x for the connection of x for the connection of display unit, GSM unit or ISDN unit display unit, GSM unit or ISDN unit CAN bus (RJ 45) 2 x for max. 6 sensors each = 2 sensors in total (quantity restriction, see page 45) x for max. 4 sensors (quantity restriction, see page 45) Digital inputs (terminal) 2 2 Relay output (terminal) Changeover contact max. 24 V (DC), A Changeover contact max. 24 V (DC), A Push-button x acknowledgement button x acknowledgement button Concealed reset button x service button x service button Piezo signal generator LED display x multi-colour OK/warning/alarm x multi-colour OK/warning/alarm Rear LED x for the network status x for the network status Ethernet TCP/IPv4, TCP/IPv6, SNMPv, SNMPv2c, SNMPv, Telnet, SSH, FTP, SFTP, HTTP, HTTPS, NTP, DHCP, DNS, SMTP, Syslog, LDAP TCP/IPv4, TCP/IPv6, SNMPv, SNMPv2c, SNMPv, Telnet, SSH, FTP, SFTP, HTTP, HTTPS, NTP, DHCP, DNS, SMTP, Syslog, LDAP Input 24 V DC (jack) x for connecting power pack x for connecting power pack x for direct connection or x for direct connection or Input 24 V DC (terminals) for connecting power pack for connecting power pack Power over Ethernet PoE x 5.4 W x 5.4 W Time function Real-time clock, energy-buffered (24 h) without battery/accumulator, with NTP Real-time clock, energy-buffered (24 h) without battery/accumulator, with NTP User administration LDAP LDAP User interface Integral WEB server Integral WEB server Control room connection Integral OPC UA server Integral OPC UA server Temperature sensor NTC sensor with cable, supplied loose NTC sensor with cable, supplied loose Access sensor Infrared technology in the enclosure front Infrared technology in the enclosure front 450 Rittal Catalogue 4/IT infrastructure

7 Control units for Processing Unit Sensors/accessories Compact Page Maximum quantity I/O Unit, 8 digital inputs + 4 relay outputs Power Unit, input (C4) + 2 outputs (C) 20 V, 50/60 Hz For switching 0 A total current (fan/heater etc.) For measuring current, voltage, power, energy Also required: CAN bus connection cable /.095, see page 457 Mounting unit, U, , see page 458 sensors for direct connection Compact Page Maximum quantity Temperature sensor with external sensor Temperature/humidity sensor Infrared access sensor Vandalism sensor Analog airflow sensor ) 454 Analog differential pressure sensor Universal sensor (2x digital input and 4 20 ma) ) Max. 5 pieces for power supply with PoE Also required: CAN bus connection cable /.095, see page 457 Interface for CMC II sensors Compact Page Maximum quantity CAN bus sensor For connecting the following products: 5 x access sensors (packs of 2), connect a max. of 5 in series x smoke detector x motion detector x leakage sensor x leakage sensor, with sensor length 5 m / x fire detector and extinguisher system DET-AC Plus with messages / x early fire detector system DET-AC Plus with messages /2 x door control system for one rack Also required: CAN bus connection cable /.095, see page 457 Rittal Catalogue 4/IT infrastructure 45

8 Accessories Access system The CAN bus access is designed for one door. It has an integral IR access sensor and may be connected to one handle system and one reader unit. Compact Page Maximum quantity CAN bus access ) For connection to handle: x TS 8 handle with master key function ) 455 For connection to reader unit: x coded lock ) 455 x transponder reader ) 455 ) Max. 5 pieces for power supply with PoE Also required: CAN bus connection cable /.095, see page 457 Interface for PSM, PCU The products listed may be connected to the / Compact via CAN bus unit , see page 456. Compact Page Maximum quantity CAN bus unit For connecting the following products: 2 x 4 x Rittal Power Control Unit (PCU) 8-way x 4 x Rittal Power Control Unit (PCU) C LED, 8-way x 4 x Rittal Power Control Unit (PCU) C/9 LED, 6-way x 4 x PSM socket module C, 8-way x 4 x PSM socket module C/earthing-pin, 6-way x 4 x PSM socket module C/9, 6-way x 4 x PSM socket module C/earthing-pin LED, 6-way x 4 x PSM socket module C LED, 8-way x 4 x PSM socket module C/9 LED, 6-way Accessories: Power supply unit and connection cable , see page 457 CAN bus connection cable /.095, see page 457 Mounting unit, U, , see page 458 Note: Allow one power pack for every CAN bus unit 452 Rittal Catalogue 4/IT infrastructure

9 PSM and slave PDU for direct connection Accessories Compact Page Maximum quantity PSM measuring bars 6 A, with 2 infeeds PSM measuring bars 2 A, with infeed PSM MID measuring module 6 A, with 2 infeeds PSM MID measuring module 2 A, with 2 infeeds Slave PDU international, managed, 6 A, 2 x C Slave PDU international, managed, 6 A, 24 x C, 4 x C Slave PDU international, managed, 2 A, 24 x C, 4 x C Slave PDU international, managed, 6 A, 8 x C, x C Slave PDU international, managed, 6 A, 24 x C, 6 x C Slave PDU international, managed, 2 A, 24 x C, 6 x C Slave PDU UK, managed, A, 6 x UK Slave PDU UK, managed, 6 A, 6 x UK, 4 x C Slave PDU UK, managed, 2 A, 6 x UK, 4 x C Accessories: CAN bus connection cable /.095, see page 457 Rittal Catalogue 4/IT infrastructure 45

10 Accessories control units/ sensors Material: Plastic Surface finish: Front: Smooth Enclosure: Textured Colour: Front: RAL 9005 Enclosure: RAL 705 Protection category IP to IEC : IP 0 Connection RJ 45 2 x CAN bus Inputs Outputs IO Unit C NC NO C NC NO C NC NO C NC NO C Control unit I/O unit Inputs for earth-free signals Relay output (changeover contact) can handle loads of up to max. 24 V (DC)/ A 8 x digital 4 x relays Power Unit C Control unit, power unit Switches 2 outputs Measures voltage, current, power, work For controlling and switching fans, heaters, equipment x voltage C V 50/60 Hz 2 x current C Aggregate current max. 0 A C Temperature sensor External NTC sensor, 2 m cable Measurement range for external sensors: -40 C +80 C C Temperature/humidity sensor Measurement range: 0 C +55 C/ 5 % relative humidity % relative humidity 700. Infrared access sensor Monitoring and reflector on the door, spacing adjustable Vandalism sensor Axis: x, y, z Acceleration limits: -7 7 g, adjustable Analog airflow sensor External airflow sensor: 4 20 ma Measurement range: m/s Application: Fan, filter, climate control devices P 2 Analog differential pressure sensor 2 pressure measuring points (infeed via hose) Measurement range: -500 m Pa +500 m Pa Application: Cold aisle containment, raised floor Universal sensor Choice of digital inputs for an application: Earth-free signals S 0 Input for energy measurement systems Wiegand interface (external access systems) x digital may be switched over to pulse input S 0 or a Wiegand interface x analog 4 20 ma Rittal Catalogue 4/IT infrastructure

11 Accessories Interface for sensors Connection RJ 45 2 x CAN bus Input RJ 2 Output RJ 2 CAN Bus Sensor 2 CAN bus sensor For connecting one CMC II sensor x CMC II access sensor Sensor: Reed contact/magnet Max. 5 reed contacts in series 2 m cable included with the supply x CMC II smoke detector Sensor: Visual 2 m cable included with the supply x CMC II motion detector Sensor: Infrared 2 m cable included with the supply x CMC II leak sensor Sensor: Point infrared sensor 2 m cable included with the supply x CMC II leak sensor 5 m Sensor: 5 sensitive cables 2 m cable included with the supply x Access system Connection Inputs Outputs RJ 45 2 x CAN bus RJ 2 Flat-pin connector RJ 2 Flat-pin connector CAN Bus Access 2 CAN bus access For connecting one handle and one reader unit for door monitoring Integral IR access sensor x x Handles TS 8 handle with master key function Handle monitoring Rated voltage: 24 V (DC) m cable, 2 m extension cable included with the supply x reader units Coded lock Transponder reader Numerical code from 0 8 digits may be selected Transponder technology: Mifare m cable included with the supply x Rittal Catalogue 4/IT infrastructure 455

12 Accessories Interface for PSM, PCU Material: Plastic Surface finish: Front: Smooth Enclosure: Textured Colour: Front: RAL 9005 Enclosure: RAL 705 Protection category IP to IEC : IP 0 Connection RJ 45 2 x CAN bus Inputs CAN Bus Unit C + CAN bus unit For connecting: PSM socket strips PCU mm (9 ) socket strips 2 x for PSM, PCU, see page 452 For operating the required connection clamp for the 24 V power pack CAN Bus DRC C + CAN bus DRC For connecting: RFID controller Max. x RFID controller, see page 462 Connection clamps for the 24 V power pack (optional) PSM MID measuring module see page 42 New 456 Rittal Catalogue 4/IT infrastructure

13 Accessories Power supply unit for, Compact, CAN bus unit, CAN bus DRC, Door Control System. Technical specifications: Input voltage: V / 50/60 Hz Output voltage: 24 V (DC)/2.5 A Length of 24 V DC connection cable: 0.6 m Supply includes: 4 mounting feet Packs of pc(s) Also required: Connection cable, see page 457 Accessories: Mounting unit, see page 458 Programming cable For commissioning the Processing Unit () or Compact. Supply includes: CD with driver and system description Packs of pc(s) CAN bus connection cable This can be used to connect the with the CAN bus sensors III, units III, control units III as a bus. Also for cabling the CAN bus sensors III, units III, control units III together. CAN bus connection cable Length m Packs of RJ pc(s) RJ 45 pc(s) RJ 45.5 pc(s) RJ 45 2 pc(s) RJ 45 pc(s) RJ 45 4 pc(s) RJ 45 5 pc(s) RJ 45 0 pc(s) Connection cable/extension For connecting to: power pack C power unit C PCU C9 PDU C9 Technical specifications: PVC cable, -pole, with IEC cable coupling (non-heating appliances) with contact protection CEE22 Length: Minimum.8 m Country Version Voltage Volt Packs of D/F/B/C 20 pc(s) Non-heating appliance extension C/C4 Connection cable D/C9 Connection cable C9/C20 20/5 pc(s) /5 pc(s) /5 pc(s) Rittal Catalogue 4/IT infrastructure 457

14 Accessories Extension cable RJ 2 with RJ 2 connector/jack To extend the cable connections to CMC II sensors. Length m Packs of 2 pc(s) Mounting unit, U To accommodate Compact Control units CAN bus unit CAN bus DRC power pack Can accommodate up to units and is attached to the mm (9 ) frame. Material: Sheet steel Surface finish: Zinc-plated Supply includes: 2 blanking covers Packs of pc(s) Accessories: Cable clamp strap , see page 458 Cable clamp strap For rear attachment on the mounting unit. Material: Sheet steel, 2 mm Surface finish: Zinc-plated Supply includes: Assembly parts Packs of pc(s) Mounting unit To accommodate Compact Control units CAN bus unit CAN bus DRC power pack Can accommodate one unit and is mounted on the enclosure frame. Material: Sheet steel Surface finish: Zinc-plated Packs of pc(s) Rittal Catalogue 4/IT infrastructure

Monitoring system CMC III

Monitoring system CMC III Monitoring system CMC III ENCOSURES POWER DISTRIBUTION CIMATE CONTRO INFRASTRUCTURE SOFTWARE & SERVICES W x H x D mm Temperature range Operating humidity range Sensors/CAN bus connection units Max. overall

More information

Technical System Catalogue CMC III Monitoring System

Technical System Catalogue CMC III Monitoring System Technical System Catalogue CMC III Monitoring System CMC III monitoring system CMC III Processing Unit 3 6 1 5 7 4 8 9 10 11 Computer Multi Control (CMC) is an alarm system for network and server enclosures,

More information

Power Distribution Unit

Power Distribution Unit 414 Simple assembly Compact design Toolless clip attachment in the TS-IT Flexible mounting at the required height in the zero-u space lso suitable for individual installation on the enclosure frame Reliable

More information

Modular PDU Smart metering for your IT

Modular PDU Smart metering for your IT Modular PDU Smart metering for your IT Extremely flexible The modular PDU 2 Rittal modular PDU Modern IT equipment is constantly evolving, requiring permanent adjustments to the IT infrastructure. With

More information

Security 5.6. Monitoring system CMC-TC. Security individual and flexible. Security. communication between the Master and Processing Unit II.

Security 5.6. Monitoring system CMC-TC. Security individual and flexible. Security. communication between the Master and Processing Unit II. Monitoring system CMC-TC individual and flexible The CMC-TC offers a new dimension in flexibility, efficiency, technology and cost-effectiveness. The modular master/slave system uses network technology

More information

IT infrastructure Efficiency-boosting solutions. nextlevel. for data centre

IT infrastructure Efficiency-boosting solutions. nextlevel. for data centre IT infrastructure Efficiency-boosting solutions nextlevel for data centre 2 Rittal IT infrastructure The whole is more than the sum of its parts. The same is true of Rittal The System. With this in mind,

More information

Smart Monitoring System compact, secure, efficient

Smart Monitoring System compact, secure, efficient Smart Monitoring System compact, secure, efficient Transparency for more efficiency Continuously record and monitor the energy consumption of plant and machinery Visualise data on a display or through

More information

The new TS IT rack Rittal IT security Rittal IT power supply Rittal IT monitoring Rittal IT climate control Rittal references

The new TS IT rack Rittal IT security Rittal IT power supply Rittal IT monitoring Rittal IT climate control Rittal references Innovations 202 The new TS IT rack... From page 4 TS IT... Page 6 3 Rittal IT power supply... From page 36 UPS Power Modular Concept... Page 38 PDU Power Distribution Unit... Page 39 43 PSM Power System

More information

Liquid Cooling Package LCP Cooling Systems

Liquid Cooling Package LCP Cooling Systems Liquid Cooling Package LCP Cooling Systems 2 Rittal LCP Rittal The System. The whole is more than the sum of its parts. The same is true of Rittal The System. With this in mind, we have bundled our innovative

More information

Data Centre In A Box

Data Centre In A Box Data Centre In A Box Data Centre In A Box Rittal s Data Centre In A Box replicates all of the key data centre capabilities but on a smaller scale. The Data Centre In A Box mitigates risk and provides compelling

More information

IT power distribution Power distribution units (PDU) Basic. Versions available:

IT power distribution Power distribution units (PDU) Basic. Versions available: IT PDU Basic 1 U With its IT PDU Basic 1 U, BACHMANN provides a huge choice of PDUs in a high-quality aluminium profile. With their extremely compact size of just 1 height unit, mm in depth and 1" in width,

More information

VizioGuard Tiny. Datasheet

VizioGuard Tiny. Datasheet Datasheet The is the ideal monitoring system for small to mediumsized infrastructures. Its modular architecture makes this system extremely versatile. The xbus port allows the connection of up to 4 peripherals.

More information

Rittal Cooling Solutions A. Tropp

Rittal Cooling Solutions A. Tropp 1 Rittal Cooling Solutions Presented by Adam Tropp 2 Agenda Cooling Strategies Aisle Containment Chimney Solution Airstream Management Rittal Liquid Cooling Packages Data Monitoring 3 Cooling strategies.

More information

ROOM GUARD VT335. Environmental Infrastructure monitoring

ROOM GUARD VT335. Environmental Infrastructure monitoring Environmental Infrastructure monitoring ROOM GUARD VT335 Environmental monitoring of any facilities, control of security breaches, temperatures, smoke, water leakages, voltages and more. Compatible with

More information

Blue e+ chillers with the principle

Blue e+ chillers with the principle Blue e+ chillers with the principle Blue e+ chillers The world s most efficient range of chillers. The principle: Efficient Energy savings of up to 70% thanks to DC inverter technology Flexible Worldwide

More information

Product Catalogue 2015 Power Distribution Monitoring & Remote I/O Radio Time Systems Isolators

Product Catalogue 2015 Power Distribution Monitoring & Remote I/O Radio Time Systems Isolators Product Catalogue 2015 Power Distribution Monitoring & Remote I/O Radio Time Systems Isolators Good. Great. GUDE. v2.5.5 Product Catalogue of Gude Analog- und Digitalsysteme Dear customer, Koeln, January

More information

PRELIMINARY. USB1 / USB2 USB host interface to read data via memory stick. Bus Out (system bus) For connection to a router

PRELIMINARY. USB1 / USB2 USB host interface to read data via memory stick. Bus Out (system bus) For connection to a router sales@jumo.co.uk info@jumo.us Data sheet 705060 Page 1/12 JUMO mtron T Measuring, Control, and Automation System Multifunction panel 840 Brief description The multifunction panel 840 has a touchscreen

More information

ROOM GUARD VT335. Environmental Infrastructure monitoring

ROOM GUARD VT335. Environmental Infrastructure monitoring Environmental Infrastructure monitoring ROOM GUARD VT335 Environmental monitoring of any facilities, control of security breaches, temperatures, smoke, water leakages, voltages and more. Compatible with

More information

Rittal KVM technology

Rittal KVM technology Rittal KVM technology Perfect Server Administration R PERFECT SERVER ADMINISTRATION WITH KVM TECHNOLOGY FROM RITTAL Rittal KVM (Keyboard Video Mouse) switches provide the perfect answer for every customer

More information

VT805 / Monitoring system

VT805 / Monitoring system Environmental Infrastructure monitoring VT805 / Monitoring system Environmental monitoring of any facilities, control of security breaches, temperatures, smoke, water leakages, voltages and more. Compatible

More information

CMC III Processing Unit / CMC III Processing Unit Compact

CMC III Processing Unit / CMC III Processing Unit Compact CMC III Processing Unit / CMC III Processing Unit Compact 7030.000 7030.010 Montage-, Installations- und Bedienungsanleitung Assembly and operating instructions Foreword Foreword Dear Customer! We would

More information

MCX08M2 Programmable controller

MCX08M2 Programmable controller Data sheet MCX08M2 Programmable controller MCX08M2 is an electronic controller that holds all the typical functionalities of MCX controllers in the compact size of 8 DIN modules: programmability connection

More information

Liquid Cooling Package LCP Cooling Systems

Liquid Cooling Package LCP Cooling Systems Liquid Cooling Package LCP Cooling Systems 2 Rittal LCP The whole is more than the sum of its parts. The same is true of Rittal The System. With this in mind, we have bundled our innovative enclosure,

More information

PDU metered/switched/ managed international UK

PDU metered/switched/ managed international UK PDU metered/switched/ managed international UK 7955.2XX 7955.4XX 7955.9XX 7955.3XX 7955.5XX Montage-, Installations- und Bedienungsanleitung Assembly and operating instructions Foreword Foreword Dear Customer!

More information

AC5160 SiPass integrated controller kit

AC5160 SiPass integrated controller kit AC5160 SiPass integrated controller kit SiPass integrated Wall housing with pre-assembled basic SiPass integrated components Equipped with one ACC (AC5100), two dual reader interfaces (ADD5100) and one

More information

VT825 / Environmental Monitoring unit. Environmental Infrastructure monitoring

VT825 / Environmental Monitoring unit. Environmental Infrastructure monitoring Environmental Infrastructure monitoring VT825 / Environmental Monitoring unit The unit is used for IT environmental control in data-centers, remote facilities, offices, industrial facilities & remote shelters.

More information

RTT I/O Unit DK Assembly, Installation and Operation

RTT I/O Unit DK Assembly, Installation and Operation EN DK 3124.200 Assembly, Installation and Operation Microsoft Windows is a registered trademark of Microsoft Corporation. Acrobat Reader is a registered trademark of Adobe Systems Incorporated. Table of

More information

TopConsole system TP. Combination options 1-part 2-part 3-part. System accessories Page 537 Monitors, keyboards From page 796 Climate control Page 389

TopConsole system TP. Combination options 1-part 2-part 3-part. System accessories Page 537 Monitors, keyboards From page 796 Climate control Page 389 opconsole system P System accessories Page 537 Monitors, keyboards From page 796 Climate control Page 389 Enclosure: Sheet steel 1.5 mm Door and console cover: Sheet steel, 2.0 mm, all-round foamed-in

More information

Specification Sheet: HT SERIES

Specification Sheet: HT SERIES Specification Sheet: HT SERIES HT Series: High Specification 19 Enclosures Hi-tech Series of 19 enclosures, supplied in self assembly (flat pack) format for ease of transportation and storage. Manufactured

More information

CMC-TC Basic CMC DK

CMC-TC Basic CMC DK CMC-TC DK 7320. Assembly, Installation and Operation A36569 04IT 74 Microsoft Windows is a registered trademark of Microsoft Corporation. Acrobat Reader is a registered trademark of Adobe Systems Incorporated.

More information

IT infrastructure Next level for data center. Rittal The System Yavor Panayotov Data center Day

IT infrastructure Next level for data center. Rittal The System Yavor Panayotov Data center Day IT infrastructure Next level for data center Rittal The System Yavor Panayotov Data center Day - 2018 1 Rittal The System - Solutions Enclosures Enclosures Small enclosures Command Panel & support arm

More information

Room Temperature Controllers

Room Temperature Controllers 3 021 Room Temperature Controllers for two-pipe fan coil units RCC10 Output for on / off valve actuator Outputs for three-speed fan Control depending on the room or return air temperature (RCC10) Automatic

More information

VT608 / Switched PDU with 8 outlets

VT608 / Switched PDU with 8 outlets Switched PDU with Monitoring VT608 / Switched PDU with 8 outlets Device is used for load management and allows to switch on/off or reboot up to 8 outlets. It has built-in temperature sensor, can connect

More information

IT solutions. News 2003 Additions to the IT Catalogue

IT solutions. News 2003 Additions to the IT Catalogue IT solutions News 2003 Additions to the IT Catalogue R Looking for success? We offer fresh power Rittal IT solutions: Worthwhile innovations For all segments of the IT market, Rittal offers fresh opportunities

More information

PLC PFC200 Controller PFC200 CS 2ETH RS

PLC PFC200 Controller PFC200 CS 2ETH RS 0-202 PLC PFC200 Controller PFC200 CS 2ETH RS Marking area Serial interface RJ-4 RJ-4 ACT X2 LNK ETH ACT X LNK X3 RS232/4 U U U4 U3 U2 U STOP RESET 0-202 SYS I/O MS NS U RST SD 0 02 A B 24V 0V + + Status

More information

CMC-TC Master II DK

CMC-TC Master II DK EN DK 70.005 Assembly, Installation and Operation A990 0 IT 74 Microsoft Windows is a registered trademark of Microsoft Corporation. Acrobat Reader is a registered trademark of Adobe Systems Incorporated.

More information

RiMatrix S Make easy.

RiMatrix S Make easy. RiMatrix S Make easy. 2 RiMatrix S Rittal The System. The whole is more than the sum of its parts. The same is true of Rittal The System. With this in mind, we have bundled our innovative enclosure, power

More information

Monitoring system LN-VT325. Environmental Infrastructure monitoring

Monitoring system LN-VT325. Environmental Infrastructure monitoring Environmental Infrastructure monitoring Monitoring system LN-VT325 Environmental monitoring of small facilities, access control, monitoring of tempertures, smoke, water leakages, voltages and more. Overview

More information

JUMO mtron T Measuring, Control, and Automation System

JUMO mtron T Measuring, Control, and Automation System Data Sheet 705001 Page 1/10 JUMO mtron T Measuring, Control, and Automation System Central processing unit Brief description The central processing unit is the heart of the system. It contains the process

More information

8-Port EN Certified Railway IP67 WATERPROOF MANAGED Gigabit PoE SWITCH. EMG8508 Series FEATURE HIGHLIGHTS PRODUCT DESCRIPTION

8-Port EN Certified Railway IP67 WATERPROOF MANAGED Gigabit PoE SWITCH. EMG8508 Series FEATURE HIGHLIGHTS PRODUCT DESCRIPTION EMG8508 Series 8-Port EN 50155 Certified Railway IP67 WATERPROOF MANAGED Gigabit PoE SWITCH FEATURE HIGHLIGHTS Up to 8 10/100/1000 BASE-T(X) ports, M12 connector Up to or 8 802.af or 802.at complaint PoE

More information

DK-PS Rack. New generation DK-PS Rack for room climate control

DK-PS Rack. New generation DK-PS Rack for room climate control DK-PS Rack DK-PS Rack New generation DK-PS Rack for room climate control Rack as the support for IT equipment is the main component of the data center; Reliable,eficiency and flexible is the main requirement

More information

SmartAisle. SmartAisleTM. Energy-efficient use of existing cooling power in data centers to

SmartAisle. SmartAisleTM. Energy-efficient use of existing cooling power in data centers to SmartAisleTM SmartAisle TM Energy-efficient use of existing cooling power in data centers 1.50 to 1.58 1.49 Emerson Network Power Smart Aisle TM The consistent physical separation of cold zones from warm

More information

Colour Change Driver All RGB luminaires are supplied complete with RJ45 plug for simple connection into a colour change driver.

Colour Change Driver All RGB luminaires are supplied complete with RJ45 plug for simple connection into a colour change driver. LED Controls A whole new dimension in lighting is now available with LEDs. The ability to dynamically change colour enables the designer to create effects never seen or experienced before. As the colour

More information

RiLine Compact The smart power distribution system

RiLine Compact The smart power distribution system RiLine Compact The smart power distribution system 2 Power distribution in a confined space Rittal are the leading suppliers of reliable power distribution and backup systems for controlgear. The new RiLine

More information

Room Temperature Controller

Room Temperature Controller 3 023 Room Temperature Controller for four-pipe fan coil units RCC30 Outputs for on / off valve actuators Outputs for three-speed fan Control depending on room or return air temperature Operating modes:

More information

Room Temperature Controller

Room Temperature Controller 3 023 Room Temperature Controller for four-pipe fan coil units RCC30 Outputs for on / off valve actuators Outputs for three-speed fan Control depending on room or return air temperature Operating modes:

More information

LANTIME M3000: Time and Frequency Synchronization Platform

LANTIME M3000: Time and Frequency Synchronization Platform Meinberg Radio Clocks Lange Wand 9 31812 Bad Pyrmont, Germany Phone: +49 (5281) 9309-0 Fax: +49 (5281) 9309-30 http://www.meinberg.de info@meinberg.de LANTIME M3000: Time and Frequency Synchronization

More information

LCP Hybrid Efficient performance with heat pipe technology

LCP Hybrid Efficient performance with heat pipe technology LCP Hybrid Efficient performance with heat pipe technology 2 LCP Hybrid The whole is more than the sum of its parts The same is true of "Rittal The System." With this in mind, we have bundled our innovative

More information

PDU Solutions. PDU Solutions

PDU Solutions. PDU Solutions Canovate offers a full range of PDU s from basic and metered ones to IP PDU s with per socket switching capability and wireless sensor connectivity. Our PDU s can be used in the most complex ISP and Colocation

More information

VIDI System Controller

VIDI System Controller 1 VIDI System Controller for OPUS DC Power Systems Product description VIDI is the advanced monitoring and control device for OPUS DC Power Systems. It delivers intelligence, an easy-to-use interface and

More information

CMC III Universal Sensor

CMC III Universal Sensor CMC III Universal Sensor DK 7030.190 Assembly and operating instructions Foreword Foreword Dear Customer, Thank you for choosing our CMC III universal sensor (referred to hereafter as "universal sensor")!

More information

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS 18 channels for HART / Modbus RTU sensors 2 digital channels 16 math channels 4 relay outputs for alarm or control

More information

INSTALLATION MANUAL Z-UMTS

INSTALLATION MANUAL Z-UMTS INSTALLATION MANUAL Datalogger HSPA + with built-in I/O, telecontrol functions, embedded UPS and advanced programming language EN SENECA s.r.l. Headquarters: Via Austria, 26 35127 PADOVA ITALY Phone +39.049.8705355-8705359

More information

Better by being quick to translate market trends into products. In this way, our innovative strength helps you to secure competitive advantages.

Better by being quick to translate market trends into products. In this way, our innovative strength helps you to secure competitive advantages. Make easy. 2 Make IT easy Rittal The System. The whole is more than the sum of its parts. The same is true of Rittal The System. With this in mind, we have bundled our innovative enclosure, power distribution,

More information

UCU Room Display. Operation Modes. Features. Applications DATASHEET

UCU Room Display. Operation Modes. Features. Applications DATASHEET DATASHEET UCU Room Display The UCU Room Display provides dedicated visually appealing Room Control display for use with UCU10FC/K Unitary Controller. The display allows the user to view and adjust selected

More information

PI Server - 19 enclosures

PI Server - 19 enclosures PI Server - 19 The PI server enclosure range has been designed to complement our original PI Data enclosure and to accommodate the requirement of a cost effective server cabinet solution. This product

More information

Description Front View of SSC-0025 Rear View of SSC-0025

Description Front View of SSC-0025 Rear View of SSC-0025 The Savant SmartControl 5 provides control, automation and expansion in a U-rack style enclosure. The SmartControl 5 includes a blend of the most popular and common control formats serial, infrared (IR),

More information

Specifications MLC Plus 50/100/200 Series

Specifications MLC Plus 50/100/200 Series Specifications MLC Plus 50/100/200 Series Memory SDRAM... 512 MB Flash... 512 MB Software and control options Software... Extron Global Configurator Plus and Professional for Windows Control options...

More information

JUMO Quantum PID100/PID200/PID300

JUMO Quantum PID100/PID200/PID300 Data sheet 702020 Page 1/12 JUMO Quantum PID100/PID200/PID300 Universal PID Controller Series Brief description The Quantum series is available in the three DIN formats 48 mm x 48 mm, 48 mm x 96 mm, and

More information

PT-7728 Series. IEC G-port Gigabit modular managed Ethernet switch. Introduction PT-7728

PT-7728 Series. IEC G-port Gigabit modular managed Ethernet switch. Introduction PT-7728 STAT PWR1 PWR2 FAULT MASTER COUPLER LNK/ACT SPEED FDX/HDX MODE COUPLER RING PORT PORT 1 2 3 4 M1 M2 M3 M4 PT-2 PT-2 Series IEC 6150-3 24+4G-port Gigabit modular managed Ethernet switch IEC 6150-3, IEEE

More information

KNX is a European Standard Protocol used for household and industrial Buliding Management System (BMS).

KNX is a European Standard Protocol used for household and industrial Buliding Management System (BMS). PRODUCT NEWS Products News: New HC-A16KNX PAGE 1 / 8 Summary 1. This advanced product news introduces the new product HC-A16KNX. 2. The details are indicated in the description. Description 1. Applicable

More information

Cabinet Interface Device

Cabinet Interface Device Cabinet Interface Device Click 650 The Click 650 provides streamlined communication for SmartSensor Matrix and Advance to traffic controllers in one compact case. This module communicates directly to the

More information

ImproX IXP20 Controller INSTALLATION MANUAL

ImproX IXP20 Controller INSTALLATION MANUAL MODEL NUMBER: ISC920-0-0-GB-XX ISC921-5-0-GB-XX IXP20 CONTROLLER SPECIFICATIONS Working Environment Plastic Housing... Power ImproX IXP20 Controller INSTALLATION MANUAL Designed to work in an indoor (dry)

More information

Control system. Type FSL-CONTROL II. Modular, stand-alone room control system, specially for decentralised ventilation systems (with bus communication

Control system. Type FSL-CONTROL II. Modular, stand-alone room control system, specially for decentralised ventilation systems (with bus communication X X testregistrierung Control system Type Central BMS interface DCP-FSL II-Stand-alone Pressure independent control valve Straight-way valve Modular, stand-alone room control system, specially for decentralised

More information

Network Components. Network Components 8

Network Components. Network Components 8 77 PSTN Router Managed Switches Unmanaged Switches Hubs Micro Transceiver Media Converter Network Adapter Ethernet Cable Network Accessories 7 for S7 S5 General Internet Modem Access Router Gateway analog

More information

MCX06C Programmable controller

MCX06C Programmable controller Data sheet MCX06C Programmable controller MCX06C is an electronic controller that holds all the typical functionalities of MCX controllers in the 32x74 mm standard size: programmability connection to the

More information

LED Controls. Lighting Controls. LED Controls

LED Controls. Lighting Controls. LED Controls Lighting Controls A whole new dimension in lighting is now available with LEDs. The ability to dynamically change colour enables the designer to create effects never seen or experienced before. As the

More information

TM241CEC24R controller M IO relay Ethernet CAN master

TM241CEC24R controller M IO relay Ethernet CAN master Characteristics controller M241 24 IO relay Ethernet CAN master Main Range of product Product or component type [Us] rated supply voltage Nov 28, 2017 Modicon M241 Logic controller 100...240 V AC Discrete

More information

TG Technical specifications

TG Technical specifications TG2-500 Technical specifications TBox TG2-500 Specifications SPECIFICATIONS Standard: 3 wires 4G Modem -4E: Europe -4N: North America Backup battery charger TG2-500: COMMUNICATION PORTS TG2-500-4E: COMMUNICATION

More information

JUMO PINOS L01. Calorimetric flow sensor. Brief description. Special features. Customer benefits. Data Sheet

JUMO PINOS L01. Calorimetric flow sensor. Brief description. Special features. Customer benefits. Data Sheet sales@jumo.co.uk info.us@jumo.net Page 1/9 JUMO PINOS L01 Calorimetric flow sensor Brief description The JUMO PINOS L01 flow sensor serves the measuring and monitoring of flow velocities of water and aqueous

More information

Poseidon 4002 MANUAL

Poseidon 4002 MANUAL Poseidon 4002 MANUAL Poseidon 4002 MANUAL POWER input 12VDC supply (jack or terminals) INPUTS Binary inputs 1 6 (for contacts) OUTPUTS Two 50V rated switchover relay contacts ETHERNET 10 or 100/10 Mbps

More information

LightRules Network Infrastructure

LightRules Network Infrastructure System and Hardware Specifications LightRules Network Infrastructure The LightRules network infrastructure enables communication and data transfer between Intelligent Light Engines, the LightRules Appliance,

More information

MGate 5102-PBM-PN Series

MGate 5102-PBM-PN Series MGate 5102-PBM-PN Series 1-port PROFIBUS-to-PROFINET gateways Features and Benefits Protocol conversion between PROFIBUS and PROFINET Supports PROFINET IO device Supports PROFIBUS DP V1 master Automatic

More information

CLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. POWER SUPPLY RELAY OUTPUTS. Power supply. 4.

CLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. POWER SUPPLY RELAY OUTPUTS. Power supply. 4. CLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. 4. Relays Power supply 2. Relays 8. Universal Inputs/ Process Bus (KNX) RS485 (Modbus) Tool (USB) Ethernet Tool (USB)/

More information

RACK-220 CHASSIS USER S MANUAL

RACK-220 CHASSIS USER S MANUAL RACK-220 CHASSIS USER S MANUAL 1 Copyright Notice This document and product is copyrighted, Jun 1999, by ICP Electronics Inc. All rights are reserved. No part of this manual may be reproduced, copied,

More information

IEI emerge MicroNode Install and Setup Guide. Contents

IEI emerge MicroNode Install and Setup Guide. Contents IEI emerge MicroNode Install and Setup Guide Contents Connecting power and the network to the MicroNode... 2 Using Power over Ethernet (PoE)... 3 or... 3 Using a 12 VDC power supply... 3 Connecting and

More information

ECL Comfort V a.c. and 24 V a.c.

ECL Comfort V a.c. and 24 V a.c. Data sheet ECL Comfort 200 230 V a.c. and 24 V a.c. Application The ECL Comfort 200 electronic controller is pre-programmed for a variety of different applications. Each application has its own card describing

More information

G GRCOW PH6PS6-D-IP44 Power Monitoring, Outlet Level. Part Number

G GRCOW PH6PS6-D-IP44 Power Monitoring, Outlet Level. Part Number Part Number Power Configuration Physical Configuration G1306 -- GRCOW246-103PH6PS6-D-IP44 Power Monitoring, Outlet Level 32A,, 7.3kW 72 in / 1829 mm Vertical Description G1306 -- GRCOW246-103PH6PS6-D-IP44

More information

Three Phase Systems-International PC302-I/MTD

Three Phase Systems-International PC302-I/MTD Three Phase Systems-International PC302-I/MTD Enclosure Power Distribution Units (epdu ) sales@pulizzi.com 800-870-2248 Fax: 605-334-4999 Front RACK MOUNTED 19 x 3.4 (2U) x 8.5 with recess mounting Approximate

More information

EDR-G902/G903 Quick Installation Guide

EDR-G902/G903 Quick Installation Guide EDR-G902/G903 Quick Installation Guide Moxa EtherDevice Router Edition 4.0, March 2016 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777

More information

Basic PDU Modules SW Meter PDU SW Meter Switch PDU SW Three Phase PDU. How to install 11-12

Basic PDU Modules SW Meter PDU SW Meter Switch PDU SW Three Phase PDU. How to install 11-12 01-02 Basic PDU 03-04 Modules 05-06 SW Meter PDU 07-08 SW Meter Switch PDU 09-10 SW Three Phase PDU 11-12 How to install Safewell Basic PDU Series Model:SW-1U-8IEC13-K Product Description Size 19 * 1U

More information

H.264 Internet Video Server

H.264 Internet Video Server H.264 Video Server Key Features Video / Audio H.264 / MPEG-4 and M-JPEG video compression simultaneously Simultaneous multi-stream support Up to 30/25 (NTSC/PAL) fps for all profiles 3DNR (3D Noise Reduction)

More information

Semi Flush-mount Room Temperature Controllers with LCD

Semi Flush-mount Room Temperature Controllers with LCD 3 076 RDF300, RDF300.02, RDF340 RDF400.01 Semi Flush-mount Room Temperature Controllers with LCD for 2-pipe, 2-pipe with el. heater and 4-pipe fan coil units for use with compressors in DX type equipment

More information

EXOcompact. Freely programmable controller

EXOcompact. Freely programmable controller flik plats revision 0 710 12 2005 EXOcompact Freely programmable controller A small and compact controller in three different I/O sizes and with different kinds of communication, with or without internal

More information

CS-12HDE444C8 (Master) Key Features. CL-12HDE444C8 (Link)

CS-12HDE444C8 (Master) Key Features. CL-12HDE444C8 (Link) CS-12HDE444C8 (Master) CL-12HDE444C8 (Link) The Server Technology Smart PDU provides local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a per-phase basis while

More information

Power Monitoring in the Data Centre

Power Monitoring in the Data Centre Power Monitoring in the Data Centre Fixed or Wireless Steve Strange RCDD ANIXTER INTERNATIONAL Agenda Energy Consumption Case Study Reasons to Monitor Power Monitoring Environmental Monitoring Asset Tags

More information

Communicative heating controller, Ethernet

Communicative heating controller, Ethernet UC150 Communicative heating controller, Ethernet Summary UC150 is a communicative room heating controller with one PWM output for control of a radiator or electrical heater. It can work autonomously, or

More information

Features and Benefits. Certifications

Features and Benefits. Certifications EDS-508A Series 8-port managed Ethernet switches Features and Benefits Turbo Ring and Turbo Chain (recovery time < 20 ms @ 250 switches), and STP/RSTP/MSTP for network redundancy TACACS+, SNMPv3, IEEE

More information

TM221ME32TK controller M IO transistor PNP Ethernet

TM221ME32TK controller M IO transistor PNP Ethernet Product data sheet Characteristics TM221ME32TK controller M221 32 IO transistor PNP Ethernet Complementary Main Discrete I/O number 32 Number of I/O expansion module Supply voltage limits Inrush current

More information

iloq S10 Online Configuration Guide

iloq S10 Online Configuration Guide iloq S10 Online Configuration Guide Document version: 1.5 (Updated 02 May 2017) Contents 1 S10 Online System... 3 1.1 Printable Documentation... 4 1.2 Licenses...4 1.3 Net Bridge N100...4 1.3.1 Net Bridge

More information

Features and Benefits. Certifications

Features and Benefits. Certifications EDS-505A Series 5-port managed Ethernet switches Features and Benefits Turbo Ring and Turbo Chain (recovery time < 20 ms @ 250 switches), and STP/RSTP/MSTP for network redundancy TACACS+, SNMPv3, IEEE

More information

FEATURES AND BENEFITS. Installation and operation. Controller

FEATURES AND BENEFITS. Installation and operation. Controller DFC 350 & 450 DISPLACEMENT FREE COOLING Function The Dantherm Displacement Free Cooling (DFC) unit is a slim, passive cooling solution designed to remove excess heat from rooms with sensitive equipment.

More information

AC5160 Controller. Fire & Security Products. SiPass integrated

AC5160 Controller. Fire & Security Products. SiPass integrated AC5160 Controller SiPass integrated Wall housing with pre-assembled SiPass basic components Equipped with one ACC, two DRI and one power supply Extendable with additional components The AC5160 is a wall

More information

Innovative. Engineering. Power. structure source. Making the complex, simple. Structure Source PDU s

Innovative. Engineering. Power. structure source. Making the complex, simple. Structure Source PDU s Structure Source PDU s Innovative Power Engineering High Quality Power Distribution for the Data Centre structure source Making the complex, simple structure source product range Rack and Server Power

More information

USER MANUAL. SL-10 Master Room Controller MODEL: P/N: Rev 4

USER MANUAL. SL-10 Master Room Controller MODEL: P/N: Rev 4 KRAMER ELECTRONICS LTD. USER MANUAL MODEL: SL-10 Master Room Controller P/N: 2900-000581 Rev 4 Contents 1 Introduction 1 2 Getting Started 2 2.1 Achieving the Best Performance 2 2.2 Safety Instructions

More information

Accessories for control enclosures. BERNSTEIN attachment solutions. Double coupling head (console version with suspension system attachment)

Accessories for control enclosures. BERNSTEIN attachment solutions. Double coupling head (console version with suspension system attachment) 25 Accessories for control enclosures BERNSTEIN attachment Single coupling head (suspended console version) Double coupling head (console version with suspension system attachment) 322.5 231 232 140 The

More information

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A) Product and functional description also functions if the bus cable is not connected or if the bus communication fails. After a long push button action (> 2 s), the other valve group is selected. The yellow

More information

Junos WebApp Secure 5.0 Hardware Guide

Junos WebApp Secure 5.0 Hardware Guide Junos WebApp Secure 5.0 Hardware Guide Junos WebApp Secure 5.0 Hardware Guide This document contains a specification for the MWS1000 hardware appliance, as well as instructions for installation into a

More information

TM241CEC24T. Main. 14 (remote I/O architecture) W with max number of I/O expansion module ma fast input. 2.

TM241CEC24T. Main. 14 (remote I/O architecture) W with max number of I/O expansion module ma fast input. 2. Product datasheet Characteristics TM241CEC24T Main Range of product Product or component type [Us] rated supply voltage Discrete input number Discrete output type Discrete output number Discrete output

More information

ZLJ\YP[`7YVIL, :[HUKHYK

ZLJ\YP[`7YVIL, :[HUKHYK :LUZVY *VU[YVS :LUZVY *VU[YVS (JJLZZ *VU[YVS (JJLZZ *VU[YVS ZLJ\YP[`7YVIL, :[HUKHYK ZLJ\YP[`7YVIL, :[HUKHYK Monitor the physical environment and receive alerts of any disturbances, such as unauthorized

More information