1 Rev Cutler-Hammer Smart Breaker Panel Control Manual

2 640 Airport Road, Suite 04 Kennesaw, GA 3044 Phone: (770) Fax: (770) ALL RIGHTS RESERVED. The information contained in this manual has been carefully checked and is believed to be accurate. However, Computer Process Controls, Inc. assumes no responsibility for any inaccuracies that may be contained herein. In no event will Computer Process Controls, Inc. be liable for any direct, indirect, special, incidental, or consequential damages resulting from any defect or omission in this manual, even if advised of the possibility of such damages. In the interest of continued product development, Computer Process Controls, Inc. reserves the right to make improvements to this manual, and the products described herein, at any time without notice or obligation.

3 Table of Contents OVERVIEW..... THE CUTLER-HAMMER SMART BREAKER SYSTEM THE CUTLER-HAMMER SMART BREAKER GATEWAY THE MULTIFLEX CHB... 2 MOUNTING THE CUTLER-HAMMER SMART BREAKER GATEWAY CHB INSIDE THE PANEL POWER WIRING GATEWAY TERMINATI JUMPER SETTINGS SMART BREAKER GATEWAY POWER WIRING CHB POWER WIRING BOARD STATUS LEDS GENERAL STATUS LED TX AND RX LEDS CODE A AND B LEDS NETWORKING THE CUTLER-HAMMER BREAKER GATEWAY GATEWAY WITH SITE CTROLLER CHB WITH GATEWAY CHB DIP SWITCH SETTINGS SITE CTROLLER SOFTWARE SETUP REFLECS E2 AND EINSTEIN Board and Application Setup Adding Lighting Schedule Applications Proof Inputs and Light Outputs Setup Proof Inputs Setup Light Outputs Setup SOFTWARE SETUP SMART BREAKER GATEWAY (HHT) HHT Screens Configuration Status CHARTS/APPENDICES MAPPING BREAKER NUMBERS TO BOARD AND POINTS (BD:PT) RO MAPPING TABLE... APPENDIX A: WORKSHEETS... 2 APPENDIX B: TROUBLESHOOTING... 4 C-H Smart Breaker Manual Table of Contents vi

4

5

6 Overview The Smart Breaker products are designed to allow CPC s family of site controllers to command control panels that activate and deactivate lights. A breaker panel generally consists of a series of circuit breakers, each of which may be flipped from OFF to and from to OFF by pulsing a DC voltage to the breaker's input. Each breaker also will have a proof checking device that can be read by a controller and used to compare the actual state of the breaker to the "virtual" state of the breaker... The Cutler-Hammer Smart Breaker System CPC s Cutler-Hammer Board (CHB) is used to interface a Cutler-Hammer Breaker Panel to CPC s family of site controllers. Because each CHB behaves as three 6AI and six 8RO boards, and because CPC site controllers have a limited number of 6AIs and 8ROs, it is possible for installations with many breakers to exceed a single controller's I/O limit. The C-H Smart Breaker Gateway allows you to drive multiple CHB points from a single I/O point, and logically combine multiple proof values from CHB inputs into a single proof value. The Gateway allows you to control as many as four C-H panels with up to 42 breakers per panel (maximum of four CHBs) with a single device that behaves as one 6AI and two 8RO boards on the site controller network. Each virtual output point of the Gateway may be mapped to one or more individual breakers controlled by its associated CHBs..3. The MultiFlex CHB The MultiFlex CHB provides both the voltage necessary to change the breaker state and the proof value to verify the state change. Because as many as 42 individual breakers may be installed in a single CH lighting panel, one board per panel may be necessary. Each MultiFlex CHB may be connected to an E2, Einstein, or REFLECS controller using the RS485 I/O Network (for E2 or Einstein) or COM A&D (REFLECS). The CHB behaves identically to three 6AI board and six 8RO boards. 2 Mounting BREAKER INPUT +2VDC PULSE = CHANGE OF STATE BREAKER LIGHTS PROOF OUTPUT Panel Panel 2 Panel 3 Panel 4 (42 Breakers) (42 Breakers) (42 Breakers) (42 Breakers) MultiFlex CHB MultiFlex CHB MultiFlex CHB MultiFlex CHB INPUT TERM MULTIFLEX CHB CHB OUTPUT Gateway Board I/O Network TERM Figure - - C-H Smart Breaker System Layout (Overview).2. The Cutler-Hammer Smart Breaker Gateway CPC Controller Figure 2- - Typical Layout of Panels, Gateway, and Controller 2.. The Cutler-Hammer Smart Breaker Gateway The Gateway is typically mounted in the same area as the site controller, near the controller s 6AI, 8RO, and other RS485 Network peripherals. The Gateway is de- C-H Smart Breaker Manual Rev

7 5A/25V 2A/250V signed to fit into a standard 3" snap track (supplied with the board) or may be mounted in a panel or on stand-offs. Follow the dimensions in Figure 2-2 for panel mounting. Figure Gateway Board Mounting Dimensions The Gateway should be mounted in an environment with ambient temperature between -40 F and 50 F, with a non-condensing relative humidity between 5% and 95%. Gateway boards are not supplied with an enclosure but come with a snap-track for easy installation. The insulation sheet and I/O board must be removed from the track before the track is mounted. The snap-track is mounted using the mounting slots. Figure 2-3 shows this installation procedure. Figure Snap-Track Installation 2.2. CHB Inside the Panel Connector Strip Cutler-Hammer Board (CHB) Mounting Hole Battery Enabler. Set to the UP position to enable. 8RO Address Connector Strip 6AI Address and Baud Rate Set Jumpers JP4-6 UP for termination Breaker Control Power F6 Set Jumpers JP2-3 UP JP7 for temperature inputs TX LED Set Jumpers JP2-3 DOWN for light level (transmit) RX LED (receive) Set Jumpers JP4-6 DOWN for non-termination (default position) JP4JP5JP6 CHB Power F5 Code A LED (flashes at a certain rate if the board is offline) Gen Status LED (heartbeat) Mounting Hole JP2 JP3 (Input ) (Input 2) +2V+5V Power Out Sensor Power 0v Sig 0v Sig Sensor Inputs Input Input v 485- I/O Network Figure 2-4 Cutler-Hammer Board Layout CHB Inside the Panel Mounting 2

8 Use mounting holes to screw board in place CHB Push down on connector strips to secure board v 485- I/O Network High-line voltage cover plate 28 VAC OFF Secondary control power transformer Power 28VAC secondary power switch wiring knock outs SHIELDED TWISTED PAIR BELDEN #876 OR EQIV. Wire + to + Wire 0v to 0v (shield) Wire - to v 485- I/O Network TO OTHER RS485 DEVICES TO OTHER RS485 DEVICES Use either knock out Figure CHB Mounting Layout (Inside Panel). Loosen screw and open the cover plate lid. 2. Flip the 28VAC Secondary Power switch to the OFF position. 3. Unscrew the cover plate and remove from the panel. 4. Mount the CHB by lining up the mounting holes and pressing down on the connector strips at each end of the board. Insert screws into the mounting holes and tighten down to fasten board in place. For more details, refer to 5. Once the CHB is in place, set the 8RO and 6AI address switches (refer to Section 5.3., CHB with Gateway). 6. Set the termination jumpers JP4-6 (UP if at the end of a daisy chain). 7. Connect board to the RS485 Network (refer to Section 5.3., CHB with Gateway). 8. Reinstall the cover plate. 9. Flip the 28VAC Secondary Power switch to the position. (28VAC control power wires must be connected in order to cycle a breaker.) 3 C-H Smart Breaker Manual Rev

9 24VAC POWER 3 Power Wiring 3.. Gateway Termination Jumper Settings TERMINATI RS485 RECEIVER BUS TERM JUMPERS RS485 RECEIVER BUS NETWORK (TO GATEWAYS AND RECEIVERS) Connect 24VAC center-tapped power to the connector indicated in Figure 3-2 #9. Note that the center tap should be earth grounded and connected to the 0v center position of the plug CHB Power Wiring Old-Style The old-style MultiFlex CHB two-board solution requires 24VAC non-center tapped power. Power wiring is the same as the MultiFlex 68 board (refer to Figure 3-3). For the last CHB on the Receiver Bus Network, set the termination jumpers to the terminated position (left), and for all other CHBs leave the termination jumpers in the no termination position (right). NO TERMINATI Figure 3- - Gateway Termination Settings The Receiver Bus is always at one end of the CHB network daisy chain, therefore jumpers should be set in the termination position. If the Gateway resides at one end of the I/O Network, set the I/O Net termination jumpers to the terminated position, otherwise leave in the no termination position Smart Breaker Gateway Power Wiring LEGEND Hand-Held Terminal Jack 7 Alarm Status LED 2 RS485 I/O Network 8 Dip Switch 3 RS485 Receiver Bus Net 9 Power Connector 4 I/O Net Term Jumpers 0 I/O Net Status LED 5 Receiver Bus Term Jumpers Receiver Bus Status LED 6 General Status LED Rx LED Tx LED JP2 JP3 JP4 8RO Addr 6AI Addr 0v SIG INPUT Figure Old-Style MultiFlex CHB New-Style S3 & S4 Network Address Power Termination Jumpers Code A LED Code B LED Gen Status LED (heartbeat) +2V +5V 0v SIG 0v SIG 0v SIG 0v SIG 0v SIG 0v SIG 0v SIG INPUT 2 INPUT 3 INPUT 4 INPUT 5 INPUT 6 INPUT 7 INPUT 8 POWER OUT 0v SIG 0v SIG 0v SIG 0v SIG 0v SIG 0v SIG 0v SIG 0v SIG INPUT 9 INPUT 0 INPUT INPUT 2 INPUT 3 INPUT 4 INPUT 5 INPUT 6 Note that the new-style CHB single board solution does not require external power (refer to Figure 2-4). The breaker board has two 64 pin connectors on the back. Those connectors plug directly into the Cutler-Hammer circuit breaker panel, and provide 28VAC (one side grounded) power and all input and output connections to control the circuit breakers. The CHB circuit common will be grounded to the metal chassis of the Cutler-Hammer panel. The breaker board has two mounting holes for #8-32 screws, one above the other, approximately centered left and right. The board functions as I/O points for three 6AI boards and six 8RO boards to an E2 or Einstein. Most installations of CHB will require the RS485 Network wiring to the controller or a Smart Breaker Gateway. +5V+5V MultiFlex CHB Figure Gateway Board Gateway Termination Jumper Settings Power Wiring 4

10 Gateway DAISY CHAIN CFIGURATI SET TERMINATING JUMPERS: RS485 I/O NET (TO CPC CTROLLER) CHB CHB CHB CHB UP DOWN DOWN DOWN UP Figure Connecting Gateway to the RS485 Network 4 Board Status LEDs When a MultiFlex board is powered up, you will be able to determine the operating status of the board by observing its status LEDs. Figure 3-3 shows the location of the CHB s status LEDs. 4.. General Status LED The Gen Status LED simply blinks GREEN once per second (heartbeat) to show that the board is powered and operational. If this light is dark, the board has likely lost power Tx and Rx LEDs WIRE + to + WIRE 0V to 0V WIRE - to - WIRE + to + WIRE 0V to 0V WIRE - to - SHIELDED TWISTED PAIR BELDEN #876 OR EQUIV. TO OTHER RS485 DEVICES TO OTHER RS485 DEVICES The Tx and Rx LEDs indicate when the CHB is sending or receiving messages on the RS485 Network. The Tx LED blinks once every time the CHB sends a response to the E2, Einstein, or REFLECS. The Rx LED blinks once when the CHB receives a message. If the CHB is connected to the network and set up to communicate with the controller, you should see these lights blinking regularly. If they do not, there may be a problem with the network. TO CHB DEVICES SHIELDED TWISTED PAIR BELDEN #876 OR EQUIV Code A and B LEDs Code A and Code B LEDs indicate failure conditions. When these LEDs are OFF, there are no failures active. When one or both of these LEDs are blinking, there are failure conditions. The rate of blinking indicates the type of failure: Code A Failure Conditions Blinking fast (4 times/second) - There is a problem with the flash memory or hardware clock on this board. This generally means the board is bad and must be replaced. Blinking slow ( time/second) - The board is not receiving any messages addressed to it. This means either the I/O Network is down or it has not yet been commissioned in the E2, Einstein, or REFLECS Network Configuration screen. Code B Failure Conditions NOTE: Code B LED is not used on the New- Style CHB. 5 Networking 5.. The Cutler-Hammer Breaker Gateway The breaker may be connected to a CPC controller using a Gateway Board. The Gateway Board is a special interface device that allows CPC s E2, Einstein, or REFLECS site controllers to communicate with up to four MultiFlex C-H boards (CHB), as if each of them were a standard 6AI Analog Input board and two 8RO Boards. The CHB allows for group programming with the CPC Hand-Held Terminal (HHT). In addition to being an interface with the site controller, the Gateway Board also allows you use a CPC Hand-Held Terminal (HHT) device to program the CHB and program to set up the Group association for the breakers of each panel. Groups provide I/O point association between the panel breakers and the site controller. 5 C-H Smart Breaker Manual Rev

11 Gateway with Site Controller The Gateway communicates with the CPC site controllers (E2, Einstein, or REFLECS) via the RS485 I/O Network (COM A & COM D for REFLECS). The Gateway is one physical RS485 load on the I/O Network that simulates one 6AI and two 8RO Boards. To connect the Gateway to the CPC RS485 I/O Network, locate the I/O Network connector and remove it from the circuit board. Secure the wire leads to the connector orienting them as shown in Figure 3-4. When you are through securing the connections, carefully plug the connector back onto the circuit board. Wire the Gateway RS485 port in a daisy chain as all other I/O Network devices. The Gateway termination jumpers should be set to the termination position if it is at the end of the daisy chain CHB with Gateway The Gateway Board communicates with the C-H Breaker units via the Receiver Bus Network. The receiver bus may be connected to a maximum of four CHBs. Each panel has up to 42 breakers and one CHB to control these breakers. To connect the Gateway to CHB, locate the receiver bus connector and remove it from the circuit board. Secure the wire leads to the connector orienting them as shown in (Figure 3-4). When you are through securing the connections, carefully plug the connector back onto the circuit board. Then daisy chain the receiver bus to the 485 connector of each CHB. A maximum of four CHBs can be connected to a Gateway. The Gateway and the last CHB on the network should have the termination jumpers set in the terminated position. 6 CHB Dip Switch Settings ADDRESS POSITI -5 NETWORK ADDRESS (-3) POSITI 6-7 BAUD RATE (9600 or 9200) BOARD BOARD 2 BOARD 3 BOARD 4 BOARD 5 BOARD 6 BOARD 7 BOARD 8 BOARD 9 BOARD 0 BOARD BOARD 2 BOARD 3 BOARD 4 BOARD 5 BOARD 6 BOARD 7 BOARD 8 BOARD 9 BOARD 20 BOARD 2 BOARD 22 BOARD 23 BOARD 24 BOARD 25 BOARD 26 BOARD 27 BOARD 28 BOARD 29 BOARD 30 BOARD BAUD RATE 9600 BAUD Figure 6- - CHB Dip Switch Settings for Network Address and Baud Rates Set 6AI address (max range -6) and 8RO address (max range -3) using Figure 6-. Use the 6AI dip switch to set the baud rate address BAUD Each CHB functions as three 6AI boards and six 8RO boards. For each panel, use Table 5- to set the 6AI and 8RO starting addresses for each CHB. For the location of the 6AI and 8RO address dip switches, refer to Figure 3-3 for the Old-Style CHB, and Figure 2-4 for the New-Style CHB. These addresses are set the same as a standard MultiFlex board. Panels 6AI 8RO Table AI and 8RO Starting Addresses Gateway with Site Controller CHB Dip Switch Settings 6

12 7 Site Controller Software Setup 7.. REFLECS Each group set up in the Gateway has its own virtual 8RO and 6AI point command of the relay and proof feedback (respectively). Refer to your controller s manual for set up instructions E2 and Einstein Board and Application Setup Set up the number of boards (one 6AI and two 8ROs) on the I/O Network from the Connected I/O screen. Press the key to open the Main Menu and press:. System Configuration 2. Network Setup 3. Connected I/O Boards and Controllers If using an Einstein controller, from the Main Status/ Home screen, press (Actions), Network Status/ Setup, and then Connected I/O Boards & Controllers Adding Lighting Schedule Applications For each group of breakers to be controlled separately, set up a Lighting Schedule application from the Add New Application screen.. Add/Delete Application 2. Add New Application 3. LOOK UP to select Lighting Control. Enter the number of desired applications in the How Many? field. If using an Einstein controller, from the Home screen or Enhanced Lighting Status screen, press (Actions), (Control Appl Setup), and then (Add Control Application). Press (Look Up) to select Enhanced Lighting. Press (Home) to return to the Home screen. TRY THIS: When creating a name for your Lighting application, incorporate the application s corresponding group number into the name. For example, PARKLIGHTS0 associates the parking lot breakers with Group. Figure 7- - Connected I/O Boards Screen Add one 6AI and two 8RO boards on this screen and press to save and exit. 7 C-H Smart Breaker Manual Rev

13 Proof Inputs and Light Outputs Setup Once the Lighting Schedule applications have been added, set up the proof inputs and light outputs for each Lighting application. The outputs of a Lighting Schedule cell control the breakers on the Cutler-Hammer panels, and the inputs are the combined proofs of all the breakers that are part of the group being controlled by the application Proof Inputs Setup Set up 6AI board inputs in Proof Setup. To enable proofing, set Enable Proofing to Yes for each Lighting application by accessing the Lighting Control Setup screen. From the Main Menu:. Press (Lighting Sched) and select the a Lighting application. 2. (Setup) to go the Setup screen for that Lighting application. If using an Einstein controller, from the Home screen or Enhanced Lighting Status screen, press (Actions), (Setup), and choose the S:Setup tab. (Note that the Proof tab is S8 and the Outputs tab is S9). Figure Lighting Proof Setup Screen 5. Set Proof Type to Only. If the light circuit is read as open when it should normally be closed, the 6AI board will send a "fail" input relay to the controller. The Gateway proofs both and OFF so that the user can select the desired proof type as ALL Values, Only, or OFF Only. If any breaker within a group fails the proof, the entire group will fail the proof. 6. In the PROOF IN input, enter the virtual board and point address of the proof input on the gateway for the lighting group. 7. Set Proof Delay to a minimum of two minutes. (0:02:00) NOTE: Cycling power to all 42 breakers can take up to 6.5 minutes. 8. Press (Next Tab) or (Prev Tab) to cursor over to C:9 Outputs tab. Figure Setup Lighting Control 3. Under the C:Setup tab, set Enable Proofing to Yes. (C8:Proof tab becomes visible once you cursor across the tabs. See Figure 7-3.) 4. Press (Next Tab) or (Prev Tab) to cursor over to C8:Proof tab. NOTE: If a breaker is assigned to a group that is not set up, a proof failure message will occur Light Outputs Setup The Lighting Outputs Setup screen is where you will set up the 8RO board and point numbers for each group for all Lighting applications. Refer to Table 9- to associate the inputs and outputs with their corresponding group, board and point numbers. E2 and Einstein Site Controller Software Setup 8

14 Figure Lighting Outputs Setup Screen For more information on setting up Lighting Schedules, refer to section 9.7 Lighting Schedules in the E2 RX Refrigeration and BX HVAC I&O Manual. 8 Software Setup 8.. Smart Breaker Gateway (HHT) Connect the HHT to the Gateway board via the HHT jack (refer to figure Figure 3-2 #). Use the HHT to assign individual breakers to a particular group. F F2 HHT Keys Cancel Enter 8... HHT Screens Function Home screen key Quick access to status information Left and right arrow keys point to the desired field to be configured Up and down arrow keys scroll through all breakers on panel screens Deletes number you have chosen and changes it to zero, and cancels overrides on selected field Saves changes (optional - use the down arrow) - Toggles between override and OFF. Toggles between override and OFF Table 8- - HHT Key Functions The Home screen is the first screen that appears. Press F at any time to return to the Home screen. CPC - CH SB GW VER:.00A03 (PRESS ) Figure 8- - Home Screen Press the down arrow key to move to the Starting Board Addresses screen. 6AI ADDR: 8RO ADDR: Figure Starting Board Addresses Screen The Gateway emulates one 6AI and two 8ROs on the I/O Network. Set the 6AI and 8RO addresses using the left or right arrow keys to activate the corresponding fields, and number the boards accordingly. The 6AI address should be the first unused board number with a valid range of - 6. The 8RO should be the next available 8RO I/O Network address with a valid range of C-H Smart Breaker Manual Rev

15 For example, if you currently have three 6AIs and six 8ROs, set the 6AI address to 4 and the 8RO address to 7. If you add a 6AI and 8RO after the Gateway, set their addresses as follows: 6AI to 5 and the 8RO to 9. Next, arrow down to the Option screen. Figure Option Screen Option No. OPTI: 3 = STATUS 2= DIAGS 3= CFIG Configuration Function Status information that can be overridden. (An asterisk "*" signifies a proof failure) 2 Diagnostics for troubleshooting 3 Configuration settings Table Option Choices Chart Use the left or right arrows to activate the OPTI: field and choose the desired option number. (Select 3 to start configuring each Panel s breakers to groups.) Press the down arrow to move to the next screen Status NOTE: If a breaker is assigned to a group that is not set up, a proof failure message will occur. From the Option screen, select for Status. The Status screen shows the status of the 6 groups and shows the or OFF state of each group and any proof failures (a proof failure is indicated by "*" after the or OFF state). Press the down arrow key to scroll through the groups. After the groups are displayed, continue pressing the down arrow key to see the or OFF state and any proof failures of each of the 42 breakers and all panels. If a group is not assigned or set to zero, a "-" will appear as the breaker status. OPTI: = STATUS 2= DIAGS 3= CFIG Figure Option Screen PANEL BRK GRP BRK 2 GRP BRK 3 GRP Figure Panel Breakers to Group Screen From this screen you can begin assigning breakers on panels through 4 to breaker groups. Refer to Table A- for a diagram of the breaker panel and the breaker number to group assignment. Use the left and right arrow keys to configure the breaker s group number. Change the group number to the group you want to associate the breaker with (a maximum number of 6). A group number field becomes active when you see the arrow appear next to the number. Use the down arrow key to scroll through all 42 breakers on each of the four panels and set the group numbers as you scroll through the breakers. Smart Breaker Gateway (HHT) Software Setup 0

16 9 Charts/Appendices 9.. Mapping Breaker Numbers to Board and Points (Bd:Pt) Up to a maximum of 6 groups can be set up, but an unlimited amount of breakers can be assigned to any given group. Y represents the 6AI address and X represents the 8RO address of the Gateway configured in Section 8..., HHT Screens as shown in Figure RO Mapping Table Table 9-2 shows how the outputs of the 8RO Board are connected to group numbers. 8RO Board # 8RO Board Outputs 8 Outputs Outputs 9-6 Table RO Mapping Associated Group Number Light Schedule Group Proof In (Bd) 6AI Addr Proof In (Pt) 6AI Points Lights Output (Bd) 8RO Addr Y X 2 Y 2 X 2 3 Y 3 X 3 4 Y 4 X 4 5 Y 5 X 5 6 Y 6 X 6 7 Y 7 X 7 8 Y 8 X 8 9 Y 9 X+ 0 Y 0 X+ 2 Y X+ 3 2 Y 2 X+ 4 3 Y 3 X+ 5 4 Y 4 X+ 6 5 Y 5 X+ 7 6 Y 6 X+ 8 Table 9- - Mapping Group Numbers to Point Numbers Lights Output (Pt) 8RO Points C-H Smart Breaker Manual Rev

17 Appendix A: Worksheets Use the workspace below to assign breakers to groups. Refer to Table A-2 for group number board and point assignment. Panel Breakers Panel 2 Breakers Panel 3 Breakers Panel 4 Breakers Group# Group# Group# Group# Group# Group# Group# Group# Table A- - Assigning Breakers to Group Numbers

18 6AI Address = Fill in the Gateway 6AI board address that you set with the HHT. 8RO Address = Fill in the Gateway 8RO board address that you set with the HHT for Groups -8. For Groups 9-6, use the next consecutive 8RO board address (add ). Light Schedule Group Proof In (Bd) 6AI Addr Proof In (Pt) 6AI Points Lights Output (Bd) 8RO Addr Table A-2 - Mapping Group Numbers to Point Numbers Lights Output (Pt) 8RO Points Group Name

19 Appendix B: Troubleshooting SYMPTOM POSSIBLE PROBLEM SOLUTI Board Offline I/O Network Problems Check wiring polarity. Verify the 485+ uses one color and the 485- uses the other color throughout the network. Check each connector for any loose wires or frayed strands between connectors. Termination Jumpers Set Incorrectly Board Not Receiving Power Verify all three jumpers are set in the UP position if the board is at the end of a daisy chain, and that all other boards are not terminated (jumpers in DOWN position). Refer to Figure 2-5 for the following steps:. Verify proper transformer wiring. Check that the 28 VAC secondary switch is in the position. 2. Verify that the secondary power is 28 VAC and the wires are connected properly. 3. Check Fuses F5 and F6. 4. Verify line voltage is connected to high-line side of the control power transformer. Dip Switches Set Incorrectly Check 8RO address, 6AI address, and baud rate settings. Refer to Section 5.3., CHB with Gateway and Section 6, CHB Dip Switch Settings. Note: after changing dip switch settings, cycle power to board using the 28 VAC secondary power switch (flip to the OFF position and then to the position).

20

Rev CH Breaker Gateway Installation and Operation Manual

Rev CH Breaker Gateway Installation and Operation Manual 026-1710 Rev 1 05-15-07 CH Breaker Gateway Installation and Operation Manual 1640 Airport Road, Suite 104 Kennesaw, GA 31044 Phone: (770) 425-2724 Fax: (770) 425-9319 ALL RIGHTS RESERVED. The information

More information

Rev Single-Channel Pulse Modulating Anti-Sweat Control (SC-PMAC) Installation and Operation Manual

Rev Single-Channel Pulse Modulating Anti-Sweat Control (SC-PMAC) Installation and Operation Manual 026-1502 Rev 2 11-20-07 Single-Channel Pulse Modulating Anti-Sweat Control (SC-PMAC) Installation and Operation Manual 1640 Airport Road, Suite 104 Kennesaw, GA 30144 Phone: (770) 425-2724 Fax: (770)

More information

Rev MultiFlex I/O Board Installation and Operation Manual

Rev MultiFlex I/O Board Installation and Operation Manual 026-1704 Rev 5 03-10-06 MultiFlex I/O Board Installation and Operation Manual 1640 Airport Road, Suite 104 Kennesaw, GA 31044 Phone: (770) 425-2724 Fax: (770) 425-9319 ALL RIGHTS RESERVED. The information

More information

Rev 3 06-APR Modular Refrigerant Leak Detection Sensor (MRLDS) Installation and Operation Manual

Rev 3 06-APR Modular Refrigerant Leak Detection Sensor (MRLDS) Installation and Operation Manual 026-1307 Rev 3 06-APR-2010 Modular Refrigerant Leak Detection Sensor (MRLDS) Installation and Operation Manual 3240 Town Point Drive NW Suite 100 Kennesaw, GA 30144, USA Phone 770-425-2724 Fax 770-425-9319

More information

Rev MultiFlex PAK Compressor/ Condenser Control Board User s Guide

Rev MultiFlex PAK Compressor/ Condenser Control Board User s Guide 026-1712 Rev 2 09-03-04 MultiFlex PAK Compressor/ Condenser Control Board User s Guide 1640 Airport Road, Suite 104 Kennesaw, GA 31044 Phone: (770) 425-2724 Fax: (770) 425-9319 ALL RIGHTS RESERVED. The

More information

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet General Information ControlKeeper 4 Installation Sheet Model# CK4-120NO- Model# CK4-277NO The ControlKeeper-4 model is shipped in one package and is configured with either a 120V or a 277V transformer.

More information

Installation & Operation Guide

Installation & Operation Guide Installation & Operation Guide (Shown with optional Override Board Cover) KMD-5831 Programmable Loop Controller PLC-28 Direct Digital Controller 902-019-04B 1 Introduction This section provides a brief

More information

E2 RX Refrigeration Controller, E2 BX HVAC Controller, and E2 CX Convenience Store Controller Installation and Operation Manual

E2 RX Refrigeration Controller, E2 BX HVAC Controller, and E2 CX Convenience Store Controller Installation and Operation Manual 026-1610 Rev 3 10-17-05 E2 RX Refrigeration Controller, E2 BX HVAC Controller, and E2 CX Convenience Store Controller Installation and Operation Manual Computer Process Controls, Inc. 1640 Airport Road

More information

POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free Instruction Manual Model 1582-10M Protection Switch January 2009 Rev O ALARMS MENU OUTPUT = CH1 AUTO POWER 1 2 MODEL 1582 SWITCH CROSS TECHNOLOGIES INC. CH1 CH2 REMOTE EXECUTE Data, drawings, and other

More information

OMX-CI-RS232 Control Interface

OMX-CI-RS232 Control Interface Control Interface 970 Rev. B 0.0. Description Integrates GRAFIK 000TM, GRAFIK 000, GRAFIK 7000TM, Softswitch8, and LCP8 systems with a touchscreen or other digital equipment that supports RS communication.

More information

EX-RC1 Remote I/O Adapter

EX-RC1 Remote I/O Adapter EX-RC1 Remote I/O Adapter The EX-RC1 interfaces between Unitronics Vision OPLCs and remote I/O Expansion Modules distributed throughout your system. The adapter is connected to a PLC via CANbus. Each adapter

More information

Installing VO2 Analog Output Boards

Installing VO2 Analog Output Boards Chapter 3-6 VO2 Description and Identification Installing VO2 Analog Output Boards The VO2 Variable Output board provides an AKC 55 system with 2 variable outputs for control of loads like variable speed

More information

STATUS Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

STATUS Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free Instruction Manual Model 1582-45L Data Switch September 2010, Rev A REMOTE LOCAL SWITCH STATUS SELECT REMOTE LOCAL LOCAL SELECT CHANNEL SELECT POWER MODEL 1582 SWITCH CROSS TECHNOLOGIES, INC. Data, drawings,

More information

Quick Start Installation Guide

Quick Start Installation Guide apc/l Quick Start Installation Guide Version A2 Document Part Number UM-201 May 2010 OVERVIEW The apc/l is an intelligent access control and alarm monitoring control panel which serves as a basic building

More information

CA-A480-A Elevator Controller. Reference & Installation Manual

CA-A480-A Elevator Controller. Reference & Installation Manual CA-A480-A Elevator Controller Reference & Installation Manual TABLE OF CONTENTS INTRODUCTION.................................................................. 4 Introduction.............................................................................................

More information

6222 Two Door Module Technical Operations Manual

6222 Two Door Module Technical Operations Manual 6222 Two Door Module Technical Operations Manual TABLE OF CONTENTS Specifications...3 Overview...4 Operations...5 Custom Access Mode...5 Standard Access Mode...5 Offline Access Mode...5 Offline Memory...5

More information

900-4RL Option Board. Refer to installation instructions for compatible supply models - PS902, PS904, PS906, and PS914. Note

900-4RL Option Board. Refer to installation instructions for compatible supply models - PS902, PS904, PS906, and PS914. Note *44487080* 44487080 DANGER To avoid risk of electric shock, turn off AC power to power supply before installing or wiring option board. 900- Option Board Installation Instructions 900- Specifications Inputs

More information

ETM-2050/ETM-2051 Service Manual

ETM-2050/ETM-2051 Service Manual Introduction Novar s Electronic Thermostat Modules (ETMs) are intelligent control modules that provide local, direct digital control of unitary, packaged, staged HVAC systems. This document: Describes

More information

Overview These instructions are presented as a guideline for installing and setting up the LX Series Breaker Control Panel.

Overview These instructions are presented as a guideline for installing and setting up the LX Series Breaker Control Panel. LX Breaker Control Panels Installation and Setup Procedure Hubbell Building Automation, Inc. 9601 Dessau Road Building One Suite 100 Austin, Texas 78754 512-450-1100 512-450-1215 Fax www.hubbell-automation.com

More information

Rev 2 08-OCT Control Link ACC Anti-Condensate Controller System Installation and Operation Manual

Rev 2 08-OCT Control Link ACC Anti-Condensate Controller System Installation and Operation Manual 026-4704 Rev 2 08-OCT-2010 Control Link ACC Anti-Condensate Controller System Installation and Operation Manual 3240 Town Point Drive NW Suite 100 Kennesaw, GA 30144 Phone: 770-425-2724 Fax: 770-425-9319

More information

COMPUTER PROCESS CONTROLS

COMPUTER PROCESS CONTROLS TECHNICAL BULLETIN Installation Instructions: ESR8 Valve Regulator (P/N 810-3195) Introduction The ESR8 Valve Regulator board (P/N 810-3195), shown in Figure 1, is a Lon- Works Echelon based electronic

More information

Installation & Operation Guide

Installation & Operation Guide & Operation Guide KMD-7301/7301C Direct Digital Controller For Air Handling Applications 880-019-02C KMD 7301 and KMD 7301C Direct Digital Controller & Operation Guide Introduction This section provides

More information

TCNM-ACBB1 Installation Manual

TCNM-ACBB1 Installation Manual The TCNM-ACBB1 is a connection box that can be used as an accessory to facilitate system connections for installation and device replacement of several Banner family reading devices. System cabling is

More information

NCH-1000 (Multiple Breaker Types) Installation Instructions

NCH-1000 (Multiple Breaker Types) Installation Instructions 20M1 12345678 NCH-1000 (Multiple Breaker Types) Installation Instructions DOC. #560502100 C 7/30/04 PRINTED IN U.S.A. Regulatory Compliance Safety This device has been tested and found to be in compliance

More information

CA111x-series Arming Station

CA111x-series Arming Station GE Security CA111x-series Arming Station Installation and Programming Guide Contents Page Product Overview...1 Removing the Covers...2 Mounting the RAS...3 Tamper Switch...3 DIP Switch Settings...3 Connections...4

More information

Installation & Operation Guide

Installation & Operation Guide Installation & Operation Guide Direct Digital VAV Controllers KMD-7001/7051 - VAV Terminal Units KMD-7002/7052 - Dual Duct VAV Units KMD-7003/7053 - Fan Induction Units 907-019-01C 1 Introduction This

More information

REFRIGERATION AND AIR CONDITIONING. On Site Guide AK2-SC 255

REFRIGERATION AND AIR CONDITIONING. On Site Guide AK2-SC 255 REFRIGERATION AND AIR CONDITIONING On Site Guide AK2-SC 255 How to Use This Guide Read this Guide completely as you install and start up your new AK2-SC 255 controller. The guide will give you thorough

More information

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Uni-I/O Modules Installation Guide UID-0808THS Uni-I/O is a family of Input/Output modules that are compatible with the UniStream control platform. This guide provides basic installation information for

More information

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs The IO-AO6X is an I/O Expansion Module that can be used in conjunction with specific Unitronics OPLC controllers. The module offers 6 12-bit isolated

More information

Model XAV2 & XAV2-LED System Installation

Model XAV2 & XAV2-LED System Installation Model XAV2 & XAV2-LED System Installation 10/09/07 This document provides instructions for installing the Polara Push Button Station (PBS) and the XAVCU2 or XAVCU2-DC Control Unit. Mounting the Push Button

More information

The Programmable 4-Way Relay Card is an optional peripheral unit that provides four individually programmable relay output circuits.

The Programmable 4-Way Relay Card is an optional peripheral unit that provides four individually programmable relay output circuits. Peripheral Relay The Programmable 4-Way Relay Card is an optional peripheral unit that provides four individually programmable relay output circuits. Up to 16 Cards can be connected to a multi-loop panel

More information

IO-PT4. Component identification. User safety and equipment protection guidelines. Unitronics Industrial Automation Systems 1

IO-PT4. Component identification. User safety and equipment protection guidelines. Unitronics Industrial Automation Systems 1 IO-PT4 I/O Expansion Module 4 PT100 Inputs (-50 to 460 C) The IO-PT4 is an I/O expansion module that can be used in conjunction with specific Unitronics OPLC controllers. The module offers 4 PT100 inputs

More information

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Vision OPLC V350-35-R34/V350-J-R34 Installation Guide The Unitronics V350-35-R34/V350-J-R34 offers the following onboard I/Os: 22 Digital Inputs, configurable via wiring to include 2 Analog and 3 HSC/Shaft-encoder

More information

DTS 310. DIN Rail Mounted, Indoor Rated Revenue Grade Electrical Sub-meter. Page 1. Measurlogic MQ A

DTS 310. DIN Rail Mounted, Indoor Rated Revenue Grade Electrical Sub-meter. Page 1. Measurlogic MQ A DTS 310 DIN Rail Mounted, Indoor Rated Revenue Grade Electrical Sub-meter Page 1 1 PRODUCT OVERVIEW... 3 1.1 SUPPLIED ITEMS... 3 1.2 DOCUMENT CONVENTIONS... 4 1.3 PRODUCT SPECIFICATION... 4 1.3.1 Current

More information

H704-42(H)(E), H704-42/1(H)(E)

H704-42(H)(E), H704-42/1(H)(E) POWER MONITORING INSTALLATION GUIDE H704-42(H)(E), H704-42/1(H)(E) Branch Current Monitor DANGER NOTICE Installer's Specifications General: Operating Temp. Range 0 to 60 C (32 to 140 F) (

More information

Digital Lighting Systems, Inc.

Digital Lighting Systems, Inc. Digital Lighting Systems, Inc. Four Channel Dry Contacts Relays Switch Pack DMX512 compatible USER'S MANUAL -UM User's Manual - Page 1 GENERAL DESCRIPTION The is a 4-channel DMX-512 compatible electro-mechanical

More information

Content. Product Description

Content. Product Description EY-modulo 4 EY-RU482F001 Room Operating Unit with Display for Fan Coil applications EY-RU483F001 Room Operating Unit with Display for VAV applications en Guidelines for the electrician Content 1 Product

More information

500 Business Center Drive Pittsburgh, PA USA CAGE 1BGJ7. SwitchMaster R5000 Series Ultra-Compact Ganged A/B Switching System

500 Business Center Drive Pittsburgh, PA USA CAGE 1BGJ7. SwitchMaster R5000 Series Ultra-Compact Ganged A/B Switching System Market Central www.secureswitch.com 500 Business Center Drive Pittsburgh, PA 15205 USA 412.494.2800 CAGE 1BGJ7 SwitchMaster R5000 Series Ultra-Compact Ganged A/B Switching System July, 2014 COMPLETE 2

More information

DLA. DMX512 Analyzer. DLA Users Manual SV2_00 B.lwp copyright ELM Video Technology, Inc.

DLA. DMX512 Analyzer. DLA Users Manual SV2_00 B.lwp copyright ELM Video Technology, Inc. DLA DMX512 Analyzer DLA DLA-HH 1 Table Of Contents IMPORTANT SAFEGUARDS... 2 DLA OVERVIEW... 3 CONNECTION... 3 OPERATION... 3 HARDWARE SETUP... 4 DLA-HH (PORTABLE) LAYOUT... 4 CHASSIS LAYOUT... 4 DLA MENU

More information

EP/2 Installation Instructions

EP/2 Installation Instructions 1 2 3 4 7 ENTER 0 5 6 8 9 CLEAR + - LOGIC ONE EP/2 EP/2 Installation Instructions DOC. #569011000 A 7/30/04 PRINTED IN U.S.A. Regulatory Compliance Safety This device has been tested and found to be in

More information

This guide provides basic information for Unitronics Models 230/260/280/290 (Non-color Screens).

This guide provides basic information for Unitronics Models 230/260/280/290 (Non-color Screens). Vision OPLC Installation Guide Models 230/260/280/290 (Non-color Screens) This guide provides basic information for Unitronics Models 230/260/280/290 (Non-color Screens). General Description Vision OPLCs

More information

CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE

CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE 13050201 (c) Copyright DIP Inc., 1996 DIP Inc. P.O. Box 9550 MORENO VALLEY, CA 92303 714-924-1730 CONTENTS DN502 PRODUCT OVERVIEW 1 DN502 INSTALLATION 1 POWER

More information

E2 Controller Wiring Practices Rev 4 19-APR-2010

E2 Controller Wiring Practices Rev 4 19-APR-2010 E2 Controller Wiring Practices 026-1903 Rev 4 19-APR-2010 1640 Airport Road Suite #104 Kennesaw, GA 30144 Phone 770-425-2724 Fax 770-425-9319 ALL RIGHTS RESERVED The information contained in this manual

More information

IO-DI8-TO8 I/O Expansion Module 8 Inputs, 8 Outputs

IO-DI8-TO8 I/O Expansion Module 8 Inputs, 8 Outputs IO-DI8-TO8 I/O Expansion Module 8 Inputs, 8 Outputs The IO-DI8-TO8 is an I/O expansion module that can be used in conjunction with specific Unitronics OPLC controllers. The module offers 8 digital inputs,

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS TM REPLACEMENT PARTS FOR USE WITH CX SERIES PANELS INSTALLATION INSTRUCTIONS Hubbell Control Solutions 9601 Dessau Road Building One Suite 100 Austin, TX 78754 Toll Free: 888-698-3242 Fax: 512-450-1215

More information

Product Data Sheet. BMS/Graphics Interface. Features

Product Data Sheet. BMS/Graphics Interface. Features BMS/Graphics Interface Product Data Sheet Features The Mxp-010 interface allows BMS systems and graphics PCs to be integrated with the Mx- 4000 series of Fire Control Panels and Remote Terminals. The interface

More information

APK INSTALLATION GUIDE

APK INSTALLATION GUIDE Rev 1.3 Dated 9/17/2008 APK INSTALLATION GUIDE This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designated

More information

OPLC Installation Guide

OPLC Installation Guide Samba OPLC SM35-J-R20/SM43-J-R20 SM70-J-R20 SM35-J-T20/SM43-J-T20 SM70-J-T20 OPLC Installation Guide 12 Digital Inputs, include 1 HSC/Shaft-encoder Input, 2 Analog inputs (only when the digital inputs

More information

Vision OPLC V TR6/V350-J-TR6

Vision OPLC V TR6/V350-J-TR6 Vision OPLC V350-35-TR6/V350-J-TR6 Installation Guide The Unitronics V350-35-TR6/V350-J-TR6 offers the following onboard I/Os: 8 Digital Inputs, configurable via wiring to include 2 Analog (current/voltage)

More information

Upgrading Einstein Using the Einstein 1.5 Upgrade Kit. An EAB board with Production Einstein 1.5 Software EEPROM Chips.

Upgrading Einstein Using the Einstein 1.5 Upgrade Kit. An EAB board with Production Einstein 1.5 Software EEPROM Chips. TECHNICAL BULLETIN Upgrading Einstein Using the Einstein 1.5 Upgrade Kit This bulletin explains how to use the components of the CPC Upgrade Kit to upgrade a pre-1.5 version Einstein unit to the latest

More information

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Uni-I/O Modules Installation Guide UIA-0402N Uni-I/O is a family of Input/Output modules that are compatible with the UniStream control platform. This guide provides basic installation information for

More information

USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10

USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10 UniStream HMI Panel Installation Guide USP-070-B10, USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10 Unitronics UniStream platform comprises control devices that provide robust, flexible solutions for

More information

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B. Vision OPLC Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V290-19-C30B and V290-19-T40B. General Description Vision OPLCs are programmable

More information

EX-RC1 Remote I/O Adapter

EX-RC1 Remote I/O Adapter EX-RC1 Remote I/O Adapter The EX-RC1 interfaces between Unitronics Vision OPLCs and remote I/O Expansion Modules distributed throughout your system. The adapter is connected to a PLC via CANbus. Each adapter

More information

BACnet Flow Controller for Fan Filter Units

BACnet Flow Controller for Fan Filter Units MANUAL SERVICE + INSTALLATION BACnet Flow Controller for Fan Filter Units BFC Series v300 Issue Date: 08/23/17 2017 Price Industries Limited. All rights reserved. TABLE OF CONTENTS Product Overview General

More information

Audisey REM-PACK-8. by Intelix

Audisey REM-PACK-8. by Intelix Audisey REM-PACK-8 by Intelix Table of Contents Overview... 3 REM-PACK-8 Contents...3 Wiring the REM-PACK-8... 4 Determing the Cabling Schematic...4 Wiring with Twisted Pair and 18 Gauge Cable...5 Preparing

More information

Control Techniques Variable-Speed Drive (VSD) Interface to E2 v and Above

Control Techniques Variable-Speed Drive (VSD) Interface to E2 v and Above TECHNICAL BULLETIN Part #: 026-4122 Revision 0 Date: 2/5/2007 Control Techniques Variable-Speed Drive (VSD) Interface to E2 v. 2.40 and Overview Beginning with version 2.40, the E2 RX, BX, and CX series

More information

General Description V TR34/V130-J-TR34 V TR34/V350-J-TR34 V430J-R34 V R34/V130-J-R34 V R34/V350-J-R34

General Description V TR34/V130-J-TR34 V TR34/V350-J-TR34 V430J-R34 V R34/V130-J-R34 V R34/V350-J-R34 Vision OPLC V130-33-TR34/V130-J-TR34 V350-35-TR34/V350-J-TR34 V430-J-TR34 V130-33-R34/V130-J-R34 V350-35-R34/V350-J-R34 V430-J-R34 Installation Guide 22 Digital Inputs, including 3 HSC/Shaft-encoder Inputs,

More information

22 Digital Inputs, including 2 Analog, 2 HSC/Shaft-encoder inputs 16 Transistor Outputs

22 Digital Inputs, including 2 Analog, 2 HSC/Shaft-encoder inputs 16 Transistor Outputs Vision PLC+HMI V130-33-T38/V130-J-T38 V350-35-T38/V350-J-T38 V430-J-T38 Installation Guide 22 Digital Inputs, including 2 Analog, 2 HSC/Shaft-encoder inputs 16 Transistor Outputs General Description All

More information

NSD/M1 Installation Instructions

NSD/M1 Installation Instructions NSD/M1 Installation Instructions DOC. #560502200 C 7/30/04 PRINTED IN U.S.A. Regulatory Compliance Safety This device has been tested and found to be in compliance with the requirements set forth in UL

More information

EA500. Installation Instructions Transponder

EA500. Installation Instructions Transponder EA500 EN Installation Instructions Transponder EA500 Installation Instructions 1.0 Overview EN 2 1.0 Overview The EA500 Transponder is the Security Escort module that provides communications between the

More information

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual This package is designed to simplify the connections to our Secured Series Hub Plus Controller. This will translate into

More information

V TU24 V350-J-TU24

V TU24 V350-J-TU24 Vision PLC+HMI V350-35-TU24 V350-J-TU24 Installation Guide 12 Digital Inputs, including 2 Analog, 2 PT100/TC,1 HSC/Shaft-encoder input 12 Transistor Outputs General Description All of the controllers covered

More information

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Uni-I/O Wide Modules Installation Guide UIS-WCB1 Uni-I/O Wide is a family of Input/Output modules that are compatible with the UniStream control platform. Wide Modules are 1.5 times as wide as Uni-I/O

More information

CDN503 HIGH DENSITY I/O ADAPTER USER GUIDE

CDN503 HIGH DENSITY I/O ADAPTER USER GUIDE CDN503 HIGH DENSITY I/O ADAPTER USER GUIDE 13050301 (c) Copyright DIP Inc., 1996 DIP Inc. P.O. Box 9550 MORENO VALLEY, CA 92303 714-924-1730 CONTENTS DN503 PRODUCT OVERVIEW 1 DN503 INSTALLATION 1 POWER

More information

M-SWITCH SWITCH INPUT IN GAS CONTROL SYSTEM INSTALLATION OPERATION AND MAINTENANCE MANUAL

M-SWITCH SWITCH INPUT IN GAS CONTROL SYSTEM INSTALLATION OPERATION AND MAINTENANCE MANUAL M-SWITCH SWITCH INPUT IN GAS CTROL SYSTEM INSTALLATI OPERATI AND MAINTENANCE MANUAL QUATROSENSE ENVIRMENTAL LTD. 5935 OTTAWA STREET, PO BOX 749 RICHMD, TARIO CANADA K0A 2Z0 PHE: (613) 838-4005 FAX: (613)

More information

IO-DI8-TO8, IO-DI8-TO8-L I/O Expansion Modules 8 Inputs, 8 Outputs

IO-DI8-TO8, IO-DI8-TO8-L I/O Expansion Modules 8 Inputs, 8 Outputs IO-DI8-TO8, IO-DI8-TO8-L I/O Expansion Modules 8 Inputs, 8 Outputs The IO-DI8-TO8 and IO-DI8-TO8-L are I/O expansion modules that can be used in conjunction with specific Unitronics OPLC controllers. The

More information

Key Switch. Document version: 1.5 (Updated 02 May 2017)

Key Switch. Document version: 1.5 (Updated 02 May 2017) Key Switch Document version: 1.5 (Updated 02 May 2017) Contents ii Contents 1 Key Switch R10S.3... 4 2 Quick Guides...4 2.1 Controlling an Electric Lock...5 2.2 Controlling an Alarm System... 5 2.3 Controlling

More information

180 Series Keypad. Handbook. Revision 2.1

180 Series Keypad. Handbook. Revision 2.1 180 Series Keypad Handbook Revision 2.1 Revision History Revision 1.0 Initial release Revision 2.0 Major update with addition of 180-40 Added 180-40 to document and various headings Note regarding unique

More information

Installation Instructions

Installation Instructions Alliance Arming Station AL-1111, AL-1116 1048520C September 2006 Copyright 2006, GE Security Inc. Introduction This is the GE Alliance Arming Station for models AL-1111 (four-line LCD) and AL-1116 (four-line

More information

The identified danger could cause physical and property damage.

The identified danger could cause physical and property damage. Samba OPLC SM35-J-T20 Installation Guide The Unitronics SM35-J-T20 offers the following onboard I/Os: 12 Digital Inputs, configurable via wiring to include 2 Analog and 3 HSC/Shaft-encoder Inputs 8 Transistor

More information

This guide provides basic information for Unitronics controller model V T2.

This guide provides basic information for Unitronics controller model V T2. Vision OPLC 12 pnp/npn Digital, including 2 Analog, 3 HSC/Shaftencoder Inputs, 12 Transistor Outputs This guide provides basic information for Unitronics controller model V350-35-T2. General Description

More information

Vision OPLC. V T38 Installation Guide. General Description

Vision OPLC. V T38 Installation Guide. General Description Vision OPLC V130-33-T38 Installation Guide The Unitronics V130-33-T38 offers the following onboard I/Os: 22 Digital Inputs, configurable via wiring to include 2 Analog and 2 HSC/Shaft-encoder Inputs 16

More information

1 1 Getting Started $ "% # + %#! & %! + % $!% +!% $% # * %&# $ +!% ' *!# * %&# $ + $$ %!% "&% &%"&% # $$ $ +!( % " % $!%! %$ + $) % "$!# %% "!

1 1 Getting Started $ % # + %#! & %! + % $!% +!% $% # * %&# $ +!% ' *!# * %&# $ + $$ %!% &% &%&% # $$ $ +!( %  % $!%! %$ + $) % $!# %% ! 2 Manual Introduction The Purpose of this Manual This manual shows you how to install, program, and maintain the equipment. It also helps you understand the system operation characteristics. Who Should

More information

Digital Lighting Systems, Inc.

Digital Lighting Systems, Inc. , Inc. PD402-DMX Four Channel Dimmer and Switch Packs 4 x 2.5 Amps @ 6VDC to 24 VDC DMX52 compatible DMX52 4 x 2.5 Amps Dimmer Pack C UL US LISTED Digital Lighting Systems, Inc. USER'S MANUAL User's Manual

More information

OMX-CI-NWK-E Control Interface

OMX-CI-NWK-E Control Interface Control Interface 369369 Rev. B 1 06.02.11 Description Integrates GRAFIK 5000TM, GRAFIK 6000, GRAFIK 7000TM, Softswitch128, and LCP128 systems with a touchscreen or other digital equipment that supports

More information

Security Management System by Diebold, Inc. LINX System Hardware Installation Guide

Security Management System by Diebold, Inc. LINX System Hardware Installation Guide Security Management System by Diebold, Inc. LINX System Hardware Installation Guide INSTALLATION GUIDE LINX Integrated Security System WSD 2000 Weatherized Status Display Table of Contents Introduction

More information

ABB Drives. User s Manual. Digital I/O Extension Module RDIO-01

ABB Drives. User s Manual. Digital I/O Extension Module RDIO-01 ABB Drives User s Manual Digital I/O Extension Module RDIO-01 Digital I/O Extension Module RDIO-01 User s Manual 3AFE 64485733 REV B EN EFFECTIVE: 10.2.2003 2003 ABB Oy. All Rights Reserved. Safety Instructions

More information

QSE-CI-NWK-E Control Interface

QSE-CI-NWK-E Control Interface Control Interface 369373 Rev. A 1 12.16.10 Description The is a versatile integration access point for Lutron s QS-based systems. Through either RS232 or TCP/IP over Ethernet, third-party devices can control

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS LIGHTING CONTROL PANELS 16 AND 24 RELAYS INSTALLATION INSTRUCTIONS INSTALLATION OVERVIEW The installation instructions contained in this document are provided as a guide for proper and reliable installation.

More information

Starzone 4000 Master Control Panel Figure 2.1 Master Control Panel

Starzone 4000 Master Control Panel Figure 2.1 Master Control Panel Starzone 4000 Master Control Panel Figure 2.1 Master Control Panel The heart of the Starzone 4000 system is the Starzone Master controller (SZM-4000). Each AHU that is to be zoned will have its own SZM-4000

More information

Vision OPLC V TR20

Vision OPLC V TR20 Vision OPLC V130-33-TR20 Installation Guide The Unitronics V130-33-TR20 offers the following onboard I/Os: 12 Digital Inputs, configurable via wiring to include 2 Analog, and 3 HSC/Shaft-encoder Inputs

More information

ICPDAS FSM-510G Series Ethernet Management Switch Quick Start

ICPDAS FSM-510G Series Ethernet Management Switch Quick Start ICPDAS FSM-510G Series Ethernet Management Switch Quick Start Version 1.0, Dec 2014 Overview The Management Ethernet Switch solutions are designed for supporting standard industrial applications. Managed

More information

Digital Lighting Systems, Inc. PD216. Two Channel Dimmer and Switch Packs PROTOCOL USER'S MANUAL. PD216-UM Rev. E - 02/03

Digital Lighting Systems, Inc. PD216. Two Channel Dimmer and Switch Packs PROTOCOL USER'S MANUAL. PD216-UM Rev. E - 02/03 Digital Lighting Systems, Inc. PD26 Two Channel Dimmer and Switch Packs PROTOCOL PD26 S2 S USER'S MANUAL PD26-UM Rev. E - 02/03 Digital Lighting Systems PD26 User's Manual - Page GENERAL DESCRIPTION The

More information

Intelligent Devices IDI 1100 Series Technical Manual

Intelligent Devices IDI 1100 Series Technical Manual Intelligent Devices IDI 1100 Series 4411 Suwanee Dam Road, Suite 510 Suwanee, GA 30024 T: (770) 831-3370 support@intelligentdevicesinc.com Copyright 2011, Intelligent Devices, Inc. All Rights Reserved

More information

EX-RC1 Remote I/O Adapter

EX-RC1 Remote I/O Adapter EX-RC1 Remote I/O Adapter The EX-RC1 interfaces between Unitronics Vision OPLCs and remote I/O Expansion Modules distributed throughout your system. The adapter is connected to a PLC via CANbus. Each adapter

More information

SuperBus Hardwire Input Module (HIM) Document Number: Rev. C September 1998

SuperBus Hardwire Input Module (HIM) Document Number: Rev. C September 1998 SuperBus Hardwire Input Module (HIM) Document Number: 466-1033 Rev. C September 1998 SuperBus Hardwire Input Module for installing a magnetic reed switch* that can provide tamper protection when the switch

More information

Dual Digital Module Technical Guide

Dual Digital Module Technical Guide Factory Packaged Controls Coil Products Dual Digital Module Table of Contents OVERVIEW... 3 INSTALLATION AND WIRING... 4 Environmental Requirements...4 Mounting...4 Power Supply and Communications...4

More information

SNAP-IT-1U Installation Guide

SNAP-IT-1U Installation Guide Chapter 1 SNAP-IT-1U Installation Guide Introduction The SNAP-IT rack-mount unit is a packaged solution for attaching electrical, electronic, and mechanical devices to an Ethernet network. Once attached

More information

UniStream. Built-in. Installation Guide: US7-B5-B1, US7-B10-B1, US7-B5-TR22, US7-B10-TR22, US7-B5-T24, US7-B10-T24

UniStream. Built-in. Installation Guide: US7-B5-B1, US7-B10-B1, US7-B5-TR22, US7-B10-TR22, US7-B5-T24, US7-B10-T24 UniStream Built-in Installation Guide: US5-B5-B1, US5-B10-B1, US5-B5-TR22, US5-B10-TR22, US5-B5-T24, US5-B10-T24 US7-B5-B1, US7-B10-B1, US7-B5-TR22, US7-B10-TR22, US7-B5-T24, US7-B10-T24 SCAN to download

More information

Royal RVV-500 (B) Retrofit Kit

Royal RVV-500 (B) Retrofit Kit Optipay BV/RC/CC into a Non-Fascia Vending Machine This document contains information for installing and configuring the JCM Optipay DBV-01 Bill Validator, RC-10 Bill Recycler and A-66 Coin Changer into

More information

MS-7000: SuperStar Reader

MS-7000: SuperStar Reader The MS-7000 SuperStar Reader The MS-7000 SuperStar Reader is intended for installation in proximity applications where an extended read range is required. The reader provides an audio beeper and a multi

More information

PTC/PT100 board 2.0 Option

PTC/PT100 board 2.0 Option PTC/PT100 board 2.0 Option Instruction Manual - English PTC/PT100 board 2.0 Option Instruction Manual - English Document number: 01-3873-01 Edition: r1 Date of release: 2006-10-30 Copyright Emotron AB

More information

Screen 2.4" 3.5" Color Touch 4.3" Color Touch. RS232/485 Yes Yes Yes* Yes* Yes* USB device, mini-b Com Ports, separate order, user-installed

Screen 2.4 3.5 Color Touch 4.3 Color Touch. RS232/485 Yes Yes Yes* Yes* Yes* USB device, mini-b Com Ports, separate order, user-installed Vision PLC+HMI V130-33-TA24/V130-J-TA24 V350-35-TA24/V350-J-TA24 V350-S-TA24/V350JS-TA24 V430-J-TA24 Installation Guide 12 Digital Inputs, including 2 Analog, 2 PT100/TC,1 HSC/Shaft-encoder input 10 Transistor

More information

ISO 9001 CERTIFIED. 607 NW 27th Ave Ocala, FL Phone: (352) or Fax: (352) SUITABLE FOR EXTERNAL DISTRIBUTION

ISO 9001 CERTIFIED. 607 NW 27th Ave Ocala, FL Phone: (352) or Fax: (352) SUITABLE FOR EXTERNAL DISTRIBUTION ISO 9001 CERTIFIED Phone: (352) 629-5020 or 800-533-3569 Fax: (352)-629-2902 ES-Key 12- Relay Board P/N 103190 and 103338 PAGE 1 of 13 1. REVISI LOG... 2 2. OVERVIEW... 3 2.1. PART NUMBERS... 3 2.2. MODULE

More information

Installation manual CF8-W-Disp-AL

Installation manual CF8-W-Disp-AL Installation manual CF8-W-Disp-AL CO 2 transmitter with two relays mounted in industrial housing prepared for Modbus communication protocol 4 7 8 8 6 3 2 5 Wall plate 5 Snap-in lid 2 PCB (Factory supplied

More information

KWIC (Kysor-Warren Interface Control) Installation and Operations Manual

KWIC (Kysor-Warren Interface Control) Installation and Operations Manual .U4 #2 C36 R38 R39 S/N U3 D37 RN33 U39 Q3 Y3 RN3. D36 R32 R3 C39 U39 Form No. 44644 Release: Rev. E Date: May 28, 999 Supersedes: Rev. D KWIC (Kysor-Warren Interface Control) Installation and Operations

More information

INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual. PCMNET V 7. xx

INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual. PCMNET V 7. xx INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual PCMNET V 7. xx INTEGRATED SYSTEMS AND CONTROLS, INC. PCMNET Users Manual Revised 2/4/2005 2003-2005 Integrated Systems and Control. Inc. PO Box

More information

SmartBlock I/O Module HE579MIX102 Isolated 6 Relay, 12 DC Inputs, 4 Analog Inputs

SmartBlock I/O Module HE579MIX102 Isolated 6 Relay, 12 DC Inputs, 4 Analog Inputs MAN0959-01 PAGE 1 Mix102 module ` SmartBlock I/O Module HE579MIX102 Isolated 6 Relay, 12 DC Inputs, 4 Analog Inputs 1 SPECIFICATIONS Digital DC Inputs Digital Relay Outputs Inputs per Module 12 Outputs

More information

ACS-30-EU-MONI-RMM2-E

ACS-30-EU-MONI-RMM2-E Multi-application heat tracing Control & Monitoring in commercial and residential buildings Technical Information Description Approvals CE marked Ambient operating Temperature range 25 C to +6 C Mounting

More information