1 KI WIREWORKS WIRE ELECTRICAL SYSTEM INTRODUCTION INFORMATION 11/1/2005

2 WIRE ELECTRICAL SYSTEM COMMONLY ASKED QUESTIONS 11/1/05 1. Q. Is this electrical system a handed/directional system? A. NO There is no right/left end or male/female end to the wireways that makes them a directional system. 2. Q. Why are we adding the wire system? A. Because of the flexibility it gives us in the configuration options we can offer to our customers and the ease of install and reconfiguration. 3. Q. What wiring configurations is the 810 system available in? A. The 810 is available in two different 10-wire systems: 622 (6) hot wires, (2) shared oversized neutral wires, (2) ground wires ((1) isolated ground and (1) building ground) 442 (4) hot wires, (4) independent neutral wires, (2) ground wires ((1) isolated ground and (1) building ground). 4. Q. What is the advantage of one configuration over the other? A. The 622 system allows you to feed more workstations from one power supply point. You have (3) convenience circuits and (3) isolated ground circuits available. (sometimes referred to as a 3+3 configuration) The 442 system provides the independent neutrals that some customers insist they must have. In our opinion, the 622 system is the better system to use. 5. Q. How many workstations will I be able to feed from one power infeed location? A. The question that must be asked right back when this question is posed would be What are you going to have powered in each workstation? Explanation: The typical limiting factor of how many workstations are on an infeed is the number of computers that are being used, specifically, the number of Amps each computer will draw. There is a tag on every UL listed electrical appliance that shows how many amps the appliance draws (ex: 1.5A = 1-1/2 amps). Once you know how many amps each computer will draw, that will help you determine how many computers you can put on any isolated ground circuit (the 4I, 5I & 6I on 622, or the 3I & 4I on 442). When doing your planning you should aim to maximum load a circuit so it will not have more than 16 amps planned for it. This gives you a cushion of 4 amps (on our 20 amp circuits) in case other electrical items are plugged in. See the following examples for how many workstations you could have on an isolated ground circuit based on the amps the computers draw: a) computers draw 2 amps each. 2 amps x 8 workstations = 16 amps, so 8 workstations max b) computers draw 2.5 amps each. 2.5 amps x 6 workstations = 15 amps, so 6 workstations max c) computers draw 3 amps each. 3 amps x 5 workstations = 15 amps, so 5 workstations max d) computers draw 3.5 amps each. 3.5 amps x 4 workstations = 14 amps, so 4 workstations max e) computers draw 4 amps each. 4 amps x 4 workstations = 16 amps, so 4 workstations max C:\Documents and Settings\Mary Lebeau\Desktop\810 elec\wwcommon 810 Questions.doc 11/1/05

3 6. Q. Both these configurations use 10-wires. What if the customer says they only have 8-wire power in their building? A. If their building supply is 422 (typical for an 8-wire configuration) they can still use our 622 system but the electrician will not power up two of the isolated ground circuits. This means you would spaceplan (3) convenience circuits and (1) isolated ground circuit. There are also several other hookup configurations we can now match. We just need to ask the customer before spaceplanning starts, what configuration of building wiring will you be supplying?. 7. Q. Can the 622 and the 442 systems be hooked together? A. No. We doubt there would ever be a situation where you would need to either. Most buildings would either be wired one way or the other, not both. The parts for each system are keyed so they can only be connected to the same system. 8. Q. Can the new wire systems be connected to the current 8-wire system used in WireWorks? A. A solution for this condition is being developed with a rollout in Q. So what do we do if we need to reconfigure an existing project that has the existing 8-wire WW directional electrical? A. The best thing to do is to segregate the 8-wire vs. the wire styles as much as possible, or convert the existing stations over to the wire system. Only WireWorks that was ordered after 1/1/02 is able to be converted to the wire electrical system. 10. Q. Where do we find the model numbers and part numbers for all the 810 electrical parts? A. Specifying sheets that show drawings of the actual parts, where they can be connected to other parts, specifying tips and model/part numbers are included with this introduction package. 11. Q. Is there an easy way to tell the difference between a 622 part and a 442 part? A. Yes. The 622 parts will have a green UL label on each part, and the 442 will have a light blue UL label. These colors are different than any others we use on other systems furniture electrical parts. C:\Documents and Settings\Mary Lebeau\Desktop\810 elec\wwcommon 810 Questions.doc 11/1/05

4 WireWorks Product Specifying WIREWORKS 810 ELECTRICAL (10 Wire) Basic Specifications: The base component of our 10 wire modular electrical system is the rigid wireway in each powered panel. Rigid wireways are available in 24", 30", 36, 42", 48", 54", and 60" wide panels, at any of four heights (base, ADA, belt and standing). There are four port locations (see below, 2 labeled "WA", 2 labeled "WC") on each end of every rigid wireway except the 24 wireway that has two WC ports on one end only. The ports allow you to plug in the various other electrical products (see below). To help in specifying the electrical products, these port locations are labeled in the drawings below. By looking at the description of each of the electrical products that follow, you will have a guideline of what can and cannot be plugged into the various locations. Example: Basefeeds have C terminals. It can plug in wherever there are WC (Wireway C) terminals on the rigid wireway. A = Most electrical Accessories C = Circuit Receptacles Note: Rigid wireways may be attached to the horizontal frame members by snapping up from the bottom, or down from the top, depending on the position of the frame member. No screws or fasteners are required. All connection points have the letter N and an arrow pointing up to help you install the parts in the correct position. Identifying 622 vs. 442 parts: All 622 parts will have a green UL label applied to them. All 442 parts will have a light blue UL label applied to them. Wireway Part Numbers 622 PWET6WW(Size) size 442 PWET4WW(Size) size WWS /05

5 Model # Part # Plug-In Location Key Picture (6-2-2 System) (4-4-2 System) Universal Base Infeeds (6) PWET6BFU(color) (C) C (4) PWET4BFU(color) (C) Model # includes a receptacle bezel and filler plate Plugs into any receptacle location Universal Base Infeed can be field rotated so conduit routes either to the right or the left Use a ½ Liquid tight fitting (RACO #3542) to connect to the building Ceiling Infeed (6) PWET6TF(7or10)(color) (144or216) A (4) PWET4TF(7or10)(color) (144or216) Model # includes aluminum power pole (7 or 10 ) and required trim Part # (actual electrical) available in (144 ) or 18 (216 ) Use a ¾ oval conduit fitting (Appleton #7289V) Panel Jumpers (6) PWET6PJ(17or20) (17or20) A (4) PWET4PJ(17or20) (17or20) Used to connect rigid wireways, or Power-Pass throughs -17 used to connect at adjacent in-line panels -20 used to connect at 90 degree intersections, or to cross 3-T or 4 way intersections Power Pass-Throughs (6) PWET6PP(Size) size WA&A (4) PWET4PP(Size) size WA Sizes available,18,24,30,36,42,48,54,60 Parts are the same length as rigid wireways WA Parts connect using panel jumpers See Specification Guide for what panel jumpers to use WWS /05

6 Model # Part # Plug-In Location Key Picture (6-2-2 System) (4-4-2 System) 15 Amp Receptacles (6) PWET6RC(#)(color) #.color C (4) PWET4RC(#)(color) #.color Model # includes a receptacle bezel and filler plate 622 available in #s 1,2,3,4I,5I,6I 442 available in #s 1,2,3I,4I Receptacles with I after the # denote an isolated ground circuit Receptacles with I after the # have a stamped orange triangle on the face 20 Amp Receptacles (6) PWET620R(#)(color) #.color C (4) PWET420R(#)(color) #.color Model # includes a receptacle bezel and filler plate 622 available in #s 1,2,3,4I,5I,6I 442 available in #s 1,2,4I (Note: not available in 3I) Duplex Receptacle has one 15 amp receptacle and one 20 amp receptacle Receptacles with I after the # denote an isolated ground circuit Receptacles with I after the # have a stamped orange triangle on the face WWS /05

7 Model # Part # Plug-In Location Key Picture (6-2-2 System) (4-4-2 System) Vertical Jumper (6) PWET6VJ(20or56) or A (4) PWET4VJ(20or56) or (part #.56) is used to jump vertically from base wireway to any other height wireway 20 (part #.20) is used to jump vertically from any upper wireway to another adjacent upper wireway New York Power Base Infeed (6) PWET6NYBF.72(color) color A (4) PWET4NYBF.72(color) color City of New York approved power entry for use in base of panel only Must be specified in a non-powered panel Includes a jumper to connect to the rigid wireway in the panel next to the NY panel 72 liquidtite conduit infeed is available in standard trim colors Infeed box attaches to the bottom horizontal frame member of the panel New York Power Ceiling Infeed (6) PWET6NYTF A (4) PWET4NYTF City of New York approved power entry for use in ceiling feed applications Must be specified in a non-powered panel A power/data pole (PDF8.7 or.10) must be ordered separately Includes a jumper to connect to the rigid wireway in the panel next to the NY panel Conduit infeed is 18 in length Infeed box attaches to the bottom horizontal frame member of the panel Tech Panel Power Infeed (6) PWET6TBF(color) color A (4) PWET4TBF(color) color Used in the base of a Tech Panel only Designed to lay on the floor and fit below the lowest Tech tile 72 liquidtite conduit is available in standard trim colors Non-directional WWS /05

8 WIREWORKS Product Specifying 810-WIRE ELECTRICAL SYSTEM There are two wiring configurations in the WireWorks 810 wire electrical system. The system contains 6 conductors ( gage), two neutrals (10 gage) and two grounds ( gage). The system contains 4 conductors ( gage), four neutrals ( gage), and two grounds ( gage). Both systems provide 20 amp, 0 volt capacity circuits. The standard duplex receptacles are rated at 15 amp, 0 volt capacity. The system may be connected to a building that has 8-wire power, but you will only use four of the six circuits. See page PWS for connection diagrams. 10 WIRE INSTALLATION Power Infeed to Building Connections Have a certified electrician hard wire the panel power infeed to the building power source according to the National Electrical Code and any other applicable local codes. RECEPTACLES AVAILABLE Circuit 1 Circuit 2 Circuit 3 Circuit 4 Circuit 5 Circuit WIRES TO BE USED Black White/Black Letters Green or Bare Red White/Black Letters Green or Bare Blue White/Black Letters Green or Bare Pink White/Red Letters Green/Yellow Stripe or Gray Tan White/Red Letters Green/Yellow Stripe or Gray Orange White/Red Letters Green/Yellow Stripe or Gray RECEPTACLES AVAILABLE Circuit 1 Circuit 2 Circuit 3 Circuit 4 (Continued on next page) WIRES TO BE USED Black White/Black Letters Green or Bare Red White/Red Letters Green or Bare Blue White/Blue Letters Green/Yellow Stripe or Gray Pink White/Purple Letters Green/Yellow Stripe or Gray GAGE OF WIRE WWS /05

9 WIREWORKS Product Specifying WARNING Risk of fire or electrical shock. Do not electrically connect panel to more than one supply source. Always determine that the panel is electrically connected to one and only one source of supply. The actual order of the wires from the top down in the rigid wireway, base feeds, and top feeds are as follows: Configuration Configuration 1 White/Black Letters Circuit 1, 2, & 3 Neutral 1 White/Black Letters Circuit 1 Neutral 2 White/Red Letters Circuit 4, 5, & 6 Neutral 2 White/Red Letters Circuit 2 Neutral 3 Green or Bare Circuit 1, 2, & 3 Ground 3 White/Blue Letters Circuit 3 Neutral 4 Green/Yellow Stripe or Gray Circuit 4, 5, & 6 Ground 4 White/Purple Letters Circuit 4 Neutral 5 Orange Circuit 6 Hot 5 Green or Bare Circuit 1 & 2 Ground 6 Blue Circuit 3 Hot 6 Green/Yellow Stripe or Gray Circuit 3 & 4 Ground 7 Tan Circuit 5 Hot 7 Blue Circuit 3 Hot 8 Red Circuit 2 Hot 8 Red Circuit 2 Hot 9 Pink Circuit 4 Hot 9 Pink Circuit 4 Hot 10 Black Circuit 1 Hot 10 Black Circuit 1 Hot Note: To attach the "hardwire" end of a topfeed to a j-box, use a 3/4" oval conduit fitting (Appleton #7289V). To attach the "hardwire" end of a basefeed to a j-box, use a 1/2" liquid tight conduit fitting (RACO #3542). Note: If the building electrical is single phase, you will not be able to specify circuit 3 and 6 receptacles with the system. WWS /05

10 WIREWORKS Product Specifying 810 Wire Electrical Connection Diagrams WWS /05

11 WIREWORKS Product Specifying 810 Wire Electrical Connection Diagrams WWS /05

12 WIREWORKS Product Specifying 810 Wire Electrical System to an 8-Wire Building Connection Diagrams WWS /05

13 810 ELECTRICAL 5 BASIC SPECIFYING RULES All of the situations shown on the accompanying pages can be summed up in 5 basic rules: 1. If you are jumping between two adjacent panels at 180, use a Panel Jumper If you are jumping around a 90 corner or across an intersection, use a Panel Jumper Panel Jumper connections at non-base height must be done behind raceway tiles. The panel jumpers will not fit behind acoustic tiles. 4. Power-Pass-Throughs are the same length as rigid wireways and are connected following rules 1,2 & To connect & 18 Power-Pass-Throughs to adjacent panels, you use a Power-Pass-through in the matching panel length, and one Panel Jumper 17. (see page 810SPEC 2-2, box S)

14 C:\Documents and Settings\Mary Lebeau\Desktop\810 elec\810spec 1-1.doc 05/02/06

15 C:\Documents and Settings\Mary Lebeau\Desktop\810 elec\810spec 1-2.doc 05/02/06

16 C:\Documents and Settings\Mary Lebeau\Desktop\810 elec\810spec 1-3.doc 05/02/06

17 C:\Documents and Settings\Mary Lebeau\Desktop\810 elec\810spec 2-1.doc 05/02/06

18 C:\Documents and Settings\Mary Lebeau\Desktop\810 elec\810spec 2-2.doc 05/02/06

19 C:\Documents and Settings\Mary Lebeau\Desktop\810 elec\810spec 3-1.doc 05/02/06

Power/Data Instructions. Genius. Movable Walls. September

Power/Data Instructions. Genius. Movable Walls. September Power/Data Genius Movable Walls September 2011 Genius Movable Walls Power and Data in Shell Level 1 Conventional Boxes in Panel (conventional box and conduit) Choose 2x4 box or 4x4 box (shown). Separate

More information

B Y R N E 8 - T R A C O V E R V I E W. 1) Introduction. 2) Universally Recognized. 3) Circuitry/Keying

B Y R N E 8 - T R A C O V E R V I E W. 1) Introduction. 2) Universally Recognized. 3) Circuitry/Keying Page 1 of 6 B Y R N E 8 - T R A C O V E R V I E W 1) Introduction Byrne Electrical Specialists, Inc. provides quality, cost effective, innovative power/data distribution solutions. From initial concept

More information

Morrison, Currents and Reff Raceways Morrison, Currents and Reff Raceways

Morrison, Currents and Reff Raceways Morrison, Currents and Reff Raceways 2+2 3+3 Morrison, Currents and Reff Raceways 1 Morrison, Currents and Reff Raceways. More. Better. pioneered 2+2, the office systems raceway with the right balance of convenience power and protected power

More information

Flat Screen Garage. Table System Planning Guide WORKING FOR YOU

Flat Screen Garage. Table System Planning Guide WORKING FOR YOU Flat Screen Garage Table System Planning Guide ORKING FOR YOU Introduction Bring a new level of performance to any room with KI s Flat Screen Garage. This versatile system does double duty to make the

More information

Answer Modular Power. Page 1 of Rev V. Power Kits. Change of Height Harness. Receptical Covers

Answer Modular Power. Page 1 of Rev V. Power Kits. Change of Height Harness. Receptical Covers Answer Modular Power Change of Height Harness Power Kits Receptical Covers NOTE: Unused modular electrical connector openings are not required to be capped. NOTE: The electrician can cut conduit and wire

More information

Privacy Wall - Power & Data Box (Field Installed) Modular & Hardwire Versions

Privacy Wall - Power & Data Box (Field Installed) Modular & Hardwire Versions Privacy Wall - Power & Data Box (Field Installed) Modular & Hardwire Versions If you have a problem, question, or request, call your local dealer, or Steelcase Line 1 at 888.STEELCASE (888.783.3522) for

More information

Modular Table Power System Installation for Runner Non-folding Plug and Play Tables

Modular Table Power System Installation for Runner Non-folding Plug and Play Tables Modular Table Power System Installation for Runner Non-folding Plug and Play Tables Topic General Safety Warnings Ganging Hardware Electrical Circuits Table of Contents Page End-to-End (Page 4) End-and-Back

More information

Power Base AI. Power Base AI. Technical Sheets

Power Base AI. Power Base AI. Technical Sheets Power Base AI Power Base AI Technical Sheets odular Electrical System System Overview Haworth s Power Base AI modular electrical system provides a flexible, reconfigurable power distribution infrastructure

More information

DESCRIPTION PRODUCT CODE LIST PRICE DIMENSIONS/INCHES H L D

DESCRIPTION PRODUCT CODE LIST PRICE DIMENSIONS/INCHES H L D EVE8PD - POWER DISTRIBUTION HOUSING Power housing is specified per beam size (e.g. EVE8PD36 is for use in a 36 beam). 8 wire, 4 circuits (2+2 configuration). Accommodates two duplex receptacles per panel

More information

Emerald Cubicle System. Spec Sheet. Emerald 39,52, 65 H. skutchi.com cubicles.cc. Vol DESIGNS. inc.

Emerald Cubicle System. Spec Sheet. Emerald 39,52, 65 H. skutchi.com cubicles.cc. Vol DESIGNS. inc. Emerald Cubicle System Spec Sheet 2018 Emerald 39,52, 65 H skutchi.com cubicles.cc Vol. 1 2018 Emerald Cubicles The diverse Emerald System has endless solutions for your office. Whether you are looking

More information

Electrical Accessories

Electrical Accessories 2017 Price List and Specifications Brodart Co. Contract Furniture - Made in USA 280 North Road, Clinton County Industrial Park McElhattan, PA 17748 Toll-Free: 888-521-1884 E-Mail: furniture@brodart.com

More information

2.7 UNDER-CARPET WIREWAY

2.7 UNDER-CARPET WIREWAY 2.7 UNDER-CARPET WIREWAY U.S. List Pricing SO SUBTLE IT VIRTUALLY DISAPPEARS Connectrac 2.7 Under-Carpet Wireways. Completely concealed by carpet tile, they are Connectrac s lowest, sleekest, most invisible

More information

Smartspace Benching System

Smartspace Benching System SIN 711-2 Smartspace Benching System With the increase in office collaboration, comes an easy-to-install benching solution. Now that's smart thinking. Easily integrate power trough allows every workstation

More information

Electrical Management System (EMS) EMS-HW30C & EMS-HW50C

Electrical Management System (EMS) EMS-HW30C & EMS-HW50C Electrical Management System (EMS) EMS-HW30C & EMS-HW50C Installation & Operating Guide for: Model EMS-HW30C Rated at 120V/30A and Model EMS-HW50C Rated at 240V/50A Surgio Says Lifetime Warranty on all

More information

electrics PRODUCT MAP / TABLE OF CONTENTS ELECTRICS & COMMUNICATIONS OVERVIEW POWER ENTRY BASICS PANEL-MOUNTED WORKSTATIONS..

electrics PRODUCT MAP / TABLE OF CONTENTS ELECTRICS & COMMUNICATIONS OVERVIEW POWER ENTRY BASICS PANEL-MOUNTED WORKSTATIONS.. PRODUCT MAP / TABLE OF CONTENTS.................. ELECTRICS & COMMUNICATIONS OVERVIEW............. POWER ENTRY BASICS PANEL-MOUNTED WORKSTATIONS.. POWER & COMMUNICATIONS BASICS PANEL-MOUNTED WORKSTATIONS.....................

More information

lighting, electrics & communications

lighting, electrics & communications lighting, electrics & communications P RO D U C T M A P...................................2 9 0 289 L I G H T I N G, E L E C T R I C S & C O M M U N I C AT I O N S O V E RV I E W....2 9 4 L I G H T I N

More information

Instruction Manual. Electrical Management System (EMS) EMS-HW30C & EMS-HW50C

Instruction Manual. Electrical Management System (EMS) EMS-HW30C & EMS-HW50C Instruction Manual Electrical Management System (EMS) EMS-HW30C & EMS-HW50C EMS-HW50C EMS-HW30C! CAUTION These instructions are intended to provide assistance with the installation of this product, and

More information

lighting, electrics & communications

lighting, electrics & communications lighting, electrics & communications P RO D U C T M A P................................... 3 1 6 L I G H T I N G, E L E C T R I C S & C O M M U N I C AT I O N S B A S I C S...... 3 1 9 L I G H T I N G

More information

Progressive Industries, Inc. EMS Electrical Management System

Progressive Industries, Inc. EMS Electrical Management System Progressive Industries, Inc. EMS Electrical Management System Complete Installation Guide and Operating Instructions for: Model EMS-LCHW50 Rated at 240V/50A Manufactured by: Progressive Industries, Inc.

More information

lighting, electrics & communications

lighting, electrics & communications lighting, electrics & communications ELECTRICS & COMMUNICATIONS OVERVIEW............. LIGHTING BASICS................................. 205 POWER POLE BASICS............................... POWER ENTRY FROM

More information

Haworth Power Technical Sheets January 2018

Haworth Power Technical Sheets January 2018 Haworth Power Technical Sheets January 2018 Includes Accessories This page intentionally left blank. Table of Contents Desk Top Port Power Tap Cord Power Tap Conduit Enchanced Power Module Flip Top Unit

More information

U-SERIES SPECIFICATION GUIDE

U-SERIES SPECIFICATION GUIDE U-SERIES SPECIFICATION GUIDE Connectivity with flexibility For more product information visit connectrac.com, call us at 877-480 - 5637 or email us at info@connectrac.com ADA COMPLIANT - U.L. TESTED AND

More information

DOCKING STATION SPECIFICATIONS

DOCKING STATION SPECIFICATIONS ONE PERSON STATION Power Outlets Data Jack Plate Mouse Brackets Front Covers Cable Holes Cable Holes Overview: The Docking Station distributes power, data, and laptop storage to each user. It also offers

More information

Ratchet-Pro Slide Cover

Ratchet-Pro Slide Cover Wiremold/Legrand electrical systems conform to and should be properly grounded in compliance with requirements of the current National Electrical Code or codes administered by local authorities. Ratchet-Pro

More information

electrical evolvefurnituregroup.com 125

electrical evolvefurnituregroup.com 125 electrical evolvefurnituregroup.com 125 TECHNICAL INFORMATION STEP-BY-STEP SPECIFICATION 8-WIRE ELECTRICAL SYSTEM Step 1 Determine the location of the source power entering the Panel Run. 1. At the base

More information

SM (SURFACE MOUNTED) WIREWAY: I SERIES

SM (SURFACE MOUNTED) WIREWAY: I SERIES SM (SURFACE MOUNTED) WIREWAY: I SERIES DUPLEX POWER AND AV / TELECOM ANYWHERE The new Connectrac SM (Surface Mounted) Wireway installs directly onto any type of flooring. It s the industry s newest alternative

More information

T A B L E O F C O N T E N T S

T A B L E O F C O N T E N T S T A B L E O F C O N T E N T S UNIT 1: INTRODUCTION... 1 BESIDE STORAGE REFERENCE MANUAL FOR CANVAS... 1 CANVAS DISCLAIMER... 1 BESIDE STORAGE EXTENSION TAB... 1 MAIN SECTIONS OF THE BESIDE STORAGE TAB...

More information

ON-FLOOR WIREWAY PRICELIST AUGUST 1, 2017

ON-FLOOR WIREWAY PRICELIST AUGUST 1, 2017 PRICELIST AUGUST 1, 2017 POWER AND TELECOM SOLUTION FOR TOP-OF-FLOORING INSTALLATION The new Trac On-Floor Wireway systems install directly on top of any type of flooring. They are the industry s newest

More information

Configurable Output Distribution. 120V / 208V / 240V 60Hz. User Manual English

Configurable Output Distribution. 120V / 208V / 240V 60Hz. User Manual English Configurable Output Distribution 120V / 208V / 240V 60Hz User Manual English TABLE OF CONTENTS IMPORTANT SAFETY INSTRUCTIONS.......................... 1 GLOSSARY OF SYMBOLS....................................

More information

EMS. Electrical Management System. Progressive Industries Incorporated Morrisville, North Carolina

EMS. Electrical Management System. Progressive Industries Incorporated Morrisville, North Carolina Progressive Industries Warranty Progressive warrants its products are free from defects in materials and workmanship for a period of three years. This is in lieu of all other warranties, obligations, or

More information

U.S. List Pricing SUBTLE, ACCESSIBLE CONNECTIVITY

U.S. List Pricing SUBTLE, ACCESSIBLE CONNECTIVITY 2.7 I N - C A R P E T W I R E WAY U.S. List Pricing SUBTLE, ACCESSIBLE CONNECTIVITY Connectrac 2.7 In-Carpet Wireways. These wireways are Connectrac s lowest and sleekest. A removable wireway cap along

More information

Instruction / Installation Sheet DataComm Electronics WH Recessed Pro-Power Kit with Duplex Receptacle and Straight Blade Inlet

Instruction / Installation Sheet DataComm Electronics WH Recessed Pro-Power Kit with Duplex Receptacle and Straight Blade Inlet Instruction / Installation Sheet DataComm Electronics 45-0024-WH Recessed Pro-Power Kit with Duplex Receptacle and Straight Blade Inlet DataComm Electronics, Inc. 6349 Peachtree Street Norcross, GA 30071-1725

More information

Active UTP Transceiver Hub with Integral Camera Power Installation Guide

Active UTP Transceiver Hub with Integral Camera Power Installation Guide Active UTP Transceiver Hub with Integral Installation Guide Models Include: HubWayLD8CDS - UL Listed eight (8) Channel Active UTP Transceiver Hub with Integral HubWayLD82CDS - UL Listed eight (8) Channel

More information

Active UTP Transceiver Hub with Integral Isolated Camera Power

Active UTP Transceiver Hub with Integral Isolated Camera Power Active UTP Transceiver Hub with Integral Isolated Installation Guide HubWayEX16SP - UL Listed sixteen (16) Channel Active UTP Transceiver Hub with Integral Isolated Rev. 011810 More than just power. TM

More information

ON-FLOOR WIREWAY U.S. LIST PRICING POWER AND TELECOM SOLUTION FOR TOP-OF-FLOORING INSTALLATION ON-FLOOR WIREWAY FEATURES

ON-FLOOR WIREWAY U.S. LIST PRICING POWER AND TELECOM SOLUTION FOR TOP-OF-FLOORING INSTALLATION ON-FLOOR WIREWAY FEATURES ON-FLOOR WIREWAY U.S. LIST PRICING POWER AND TELECOM SOLUTION FOR TOP-OF-FLOORING INSTALLATION The Connectrac On-Floor Wireway systems install directly on top of any type of flooring. Extremely durable

More information

Active UTP Transceiver Hub with Integral Isolated Camera Power Installation Guide

Active UTP Transceiver Hub with Integral Isolated Camera Power Installation Guide Active UTP Transceiver Hub with Integral Isolated Installation Guide Models Include: HubWayLD8Di HubWayLD16Di - UL Listed eight (8) Channel Active UTP - UL Listed sixteen (16) Channel Active UTP Transceiver

More information

Emery County Senior Center Green River 06/07

Emery County Senior Center Green River 06/07 SECTION 262726 - WIRING DEVICES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections,

More information

Transceiver Hub with Integral Camera Power

Transceiver Hub with Integral Camera Power Passive UTP Transceiver Hub with Integral Installation Guide Models Include: HubWay8CD HubWay16CD - UL Listed eight (8) Channel Passive UTP - UL Listed sixteen (16) Channel Passive UTP Transceiver Hub

More information

Electrical Management System (EMS) EMS-HW30C & EMS-HW50C

Electrical Management System (EMS) EMS-HW30C & EMS-HW50C Electrical Management System (EMS) EMS-HW30C & EMS-HW50C Installation & Operating Guide for: Model EMS-HW30C Rated at 120V/30A and Model EMS-HW50C Rated at 240V/50A Surgio Says Lifetime Warranty on all

More information

IN-CARPET WIREWAY CANADIAN LIST PRICING ARCHITECTURAL SOLUTIONS FOR POWER AND CONNECTIVITY IN-CARPET WIREWAY FEATURES

IN-CARPET WIREWAY CANADIAN LIST PRICING ARCHITECTURAL SOLUTIONS FOR POWER AND CONNECTIVITY IN-CARPET WIREWAY FEATURES IN-CARPET WIREWAY CANADIAN LIST PRICING ARCHITECTURAL SOLUTIONS FOR POWER AND CONNECTIVITY Connectrac In-Carpet Wireways offer unobtrusive power and technology connectivity in interior spaces of all kinds.

More information

POKE-THRU FINISHES. Black Painted Flange with Nonmetallic Black Cover. Brass Flange with Nonmetallic Brass Cover. Brass Painted Flange and Cover

POKE-THRU FINISHES. Black Painted Flange with Nonmetallic Black Cover. Brass Flange with Nonmetallic Brass Cover. Brass Painted Flange and Cover POKE-THRU FINISHES Aluminum Flange with Nonmetallic Aluminum Cover* Aluminum Flange with Nonmetallic Black Cover Black Painted Flange with Nonmetallic Black Cover Gray Painted Flange with Nonmetallic Gray

More information

All Prices, Specifications, Terms and Conditions are subject to Change Without Notice

All Prices, Specifications, Terms and Conditions are subject to Change Without Notice IN-CARPET WIREWAY U.S. LIST PRICING ARCHITECTURAL SOLUTIONS FOR POWER AND CONNECTIVITY Connectrac In-Carpet Wireways offer unobtrusive power and technology connectivity in interior spaces of all kinds.

More information

EMS Electrical Management System

EMS Electrical Management System EMS Electrical Management System Complete Installation/Operating & Warranty Guide EMS-LCHW30C Rated at 120 Volts/30 Amps Manufactured & Warranted by Progressive Industries Sold & Serviced by VIP Enterprises

More information

Computer Network Design Guide Existing Systems 1 / 6

Computer Network Design Guide Existing Systems 1 / 6 COMPUTER NETWORK DESIGN GUIDELINE FOR EXISTING SYSTEMS DOCUMENT NUMBER: 16765 APPLICATION: ELEMENTARY, MIDDLE AND HIGH SCHOOL DATE OF ISSUE: 11-27-06 - First Issued NOTES: The attached guideline should

More information

Passive UTP Transceiver Hub with Integral Isolated Camera Power Installation Guide

Passive UTP Transceiver Hub with Integral Isolated Camera Power Installation Guide Passive UTP Transceiver Hub with Integral Isolated Installation Guide Models Include: HubWay8Di HubWay16Di - UL Listed eight (8) Channel Passive UTP - UL Listed sixteen (16) Channel Passive UTP Transceiver

More information

UNDERCARPET CABLING SYSTEM For Power and Communications

UNDERCARPET CABLING SYSTEM For Power and Communications UNDERCARPET CABLING SYSTEM For Power and Communications Linking Everything Together Power, Voice, and Data December 5, 2007 Undercarpet Cabling System Overview What is Undercarpet Cabling? Primary Applications

More information

MOTION LABORATORIES CHAIN HOIST MOTOR CONTROL SYSTEMS MANUAL. Basic Outline of Operation for Distro Controllers

MOTION LABORATORIES CHAIN HOIST MOTOR CONTROL SYSTEMS MANUAL. Basic Outline of Operation for Distro Controllers MOTION LABORATORIES CHAIN HOIST MOTOR CONTROL SYSTEMS MANUAL Forward The main body of text in this manual concerns four through eight channel portable chain hoist motor control systems with 208-230 VAC

More information

User s Guide. Includes Mounting, Installation, and Product Registration nd Avenue NE Arlington, WA USA (+1)

User s Guide. Includes Mounting, Installation, and Product Registration nd Avenue NE Arlington, WA USA (+1) User s Guide Includes Mounting, Installation, and Product Registration 500 19009 62nd Avenue NE Arlington, WA USA (+1) 360-435-6030 European Sales Office Barcelona, España (+34) 600-843-845 www.outbackpower.com

More information

25DTP412 12'5" Tele-Powr Pole. Features Made in USA. Material, Color, and Finish. Dimensions and Weight

25DTP412 12'5 Tele-Powr Pole. Features Made in USA. Material, Color, and Finish. Dimensions and Weight 25DTP412 12'5" Tele-Powr Pole Wiremold/Legrand Catalog Number 25DTP412 Manufacturer Wiremold/Legrand Description Tele Power Pole, Factory Wired; Shape Rectangular; 2 Compartment(S); 2 Outlet(S); Outlet

More information

12382 South Gateway Park Place, 700 Draper, UT

12382 South Gateway Park Place, 700 Draper, UT I N S T A L L A T I O N G U I D E AN-300 Structured Wiring Distribution Panel 12382 South Gateway Park Place, 700 Draper, UT 84020 1.801.617.3100 www.futuresmart.com Description Features The AN-300 Structured

More information

The 5400 Series Raceway from The Wiremold

The 5400 Series Raceway from The Wiremold 5400 Nonmetallic Raceway Nonmetallic Raceway with Twin Snap Cover System Available Factory Prewired The 5400 Series Raceway from The Wiremold Company provides wire and cable management for data, voice,

More information

Zenith Series DPB Distributed Power Busway

Zenith Series DPB Distributed Power Busway Critical Power from GE Zenith Series DPB Distributed Power Busway Key Solutions for Datacenter Overhead Power Distribution Generation 2 GE Series DPB Gen 2 Bus System Flexible. Robust. Efficient. Specifically

More information

IN-CARPET WIREWAY PRICELIST

IN-CARPET WIREWAY PRICELIST PRICELIST AUGUST 1st, 2017 ARCHITECTURAL SOLUTIONS FOR OPEN SPACE POWER AND CONNECTIVITY Trac In-Carpet Wireways offer discrete and elegant power and technology connectivity in open interior spaces of

More information

lighting, electrics & communications

lighting, electrics & communications lighting, electrics & communications P RO D U C T M A P / TA B L E C O N T E N T S.....................4 L I G H T I N G, E L E C T R I C S & C O M M U N I C AT I O N S O V E RV I E W....4 4 L I G H T

More information

25DTP4DG Tele Power Pole. Features Made in USA. Material, Color, and Finish. Dimensions and Weight

25DTP4DG Tele Power Pole. Features Made in USA. Material, Color, and Finish. Dimensions and Weight 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 25DTP4DG Tele Power Pole Wiremold/Legrand Catalog Number Manufacturer Description Weight per unit Product Category 25DTP4DG

More information

SECTION WIRING DEVICES PART 1 - GENERAL. A. Drawings and Division 1 Specification Sections, apply to this Section.

SECTION WIRING DEVICES PART 1 - GENERAL. A. Drawings and Division 1 Specification Sections, apply to this Section. SECTION 16140 WIRING DEVICES 1.01 RELATED DOCUMENTS PART 1 - GENERAL A. Drawings and Division 1 Specification Sections, apply to this Section. 1.02 SUMMARY A. This Section includes receptacles, connectors,

More information

SECTION WIRING DEVICES

SECTION WIRING DEVICES SECTION 16141 WIRING DEVICES PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

Panduit Basic Rack PDU

Panduit Basic Rack PDU Panduit Basic Rack PDU User Manual Release 1.0 Issue 1.0 Copyright 2014 Panduit Corp. All rights reserved. No part of this book shall be reproduced, stored in a retrieval system, or transmitted by any

More information

Assembly instructions

Assembly instructions Assembly instructions MKG_ENG_Instructions_H-line_V16_20170731 But also... for choosing Thank you Table of Contents GREY YELLOW PINK GREEN PURPLE DARK GREEN LIGHT BLUE ORANGE BROWN BLUE Identification

More information

NT-2300 Series Dual Circuit Track System & Accessories

NT-2300 Series Dual Circuit Track System & Accessories ILLUMINATING THE FUTURE...SINCE 1989 NT-2300 Series Dual Circuit Track System & Accessories Type Project Catalog No. Lamp/Wattage PRODUCT DESCRIPTION Low profile, extruded aluminum track with 20-Amp rated

More information

Nov. 07, 2013 p. 5 - changed the B axis unit value to from Changed by Randy per Frank s request.

Nov. 07, 2013 p. 5 - changed the B axis unit value to from Changed by Randy per Frank s request. Correction notes Nov. 07, 2013 p. 5 - changed the B axis unit value to 45.1389 from 40.0000. Changed by Randy per Frank s request. Jan. 22, 2018 p. 5 - changed the B axis unit value and corresponding picture

More information

SURFACE CONTROLTrack INSTALLATION INSTRUCTIONS

SURFACE CONTROLTrack INSTALLATION INSTRUCTIONS SURFACE CONTROLTrack INSTALLATION INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS - For use with CONTROLTrack System Only When installing or using this track system, basic safety precautions should always be

More information

MegaTrak MCU-9000 Harness Wiring

MegaTrak MCU-9000 Harness Wiring MegaTrak MCU-9000 Harness Wiring Contents: 1. MCU9000 Connector Pin-Out Schematic 2. MCU9000 Connections when replacing an MCU3000 3. MCU9000 Connections Using 120VAC ( Hot ) Hook Switch (RS485 cable)

More information

Active UTP Transceiver Hub with Integral Camera Power Installation Guide

Active UTP Transceiver Hub with Integral Camera Power Installation Guide Active UTP Transceiver Hub with Integral Installation Guide Models Include: HubWayLD8D HubWayLD16D - Eight (8) Channels - Sixteen (16) Channels HubWayLD82D HubWayLD162D - HubWayLD8D w/eight (8) HubWayAv

More information

Overview These instructions are presented as a guideline for installing and setting up the LX Series Breaker Control Panel.

Overview These instructions are presented as a guideline for installing and setting up the LX Series Breaker Control Panel. LX Breaker Control Panels Installation and Setup Procedure Hubbell Building Automation, Inc. 9601 Dessau Road Building One Suite 100 Austin, Texas 78754 512-450-1100 512-450-1215 Fax www.hubbell-automation.com

More information

EMS Electrical Management System

EMS Electrical Management System EMS Electrical Management System Complete Installation/Operating & Warranty Guide EMS-HW50C Rated at 240 Volts/50 Amps Manufactured & Warranted by Progressive Industries Sold & Serviced by VIP Enterprises

More information

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE IMPORTANT! Please read all the information on this sheet. SAVE THESE INSTRUCTIONS! NOTICE BEFORE USING READ INSTRUCTIONS COMPLETELY. TO BE INSTALLED BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH NATIONAL

More information

Installation Notes TII Model 341 Protector

Installation Notes TII Model 341 Protector Installation Notes TII Model 341 Protector (ATT-IS PEC 32918) for MERLIN Communications System In Range Out of Building (IROB) Station Installation By Trained Technician Only WARNING: Failure to follow

More information

Through/Ground Conductor/Ex and Double-Potential Terminal Blocks 1 (1.5) mm, 2000 Series

Through/Ground Conductor/Ex and Double-Potential Terminal Blocks 1 (1.5) mm, 2000 Series 54 TOPJOB @ Through/Ground Conductor/Ex and Double-Potential Terminal Blocks (.5) mm, 2000 Series 0.4 - (.5) mm I N 3.5 A (8 A) AWG 24-00 V, 0 AU 00 V, 0 A2 Terminal block width 3.5 mm / 0.38 in L 9 -

More information

WIREMOLD Tele-Power Poles

WIREMOLD Tele-Power Poles Bring Wire & Cable Down to Business WIREMOLD Tele-Power Poles Routing power, data, and A/V neatly and simply from up there to down here; that s what Tele-Power Poles are all about. Their sole purpose is

More information

ALLOY BENCHING PRODUCT SPECIFICATIONS

ALLOY BENCHING PRODUCT SPECIFICATIONS WORKSURFACES Worksurfaces are always sold with base unit Laminate 1 3 / 16 HPL (high pressure laminate) or 1⅛ TFL (thermally fused laminate) Softened 3mm PVC rim Grain direction runs left-to-right Autumn

More information

BAUM K20B KNIFE FOLDER UNIT INSTRUCTION MANUAL

BAUM K20B KNIFE FOLDER UNIT INSTRUCTION MANUAL BAUM K20B KNIFE FOLDER UNIT INSTRUCTION MANUAL 2015 BAUMFOLDER CORPORATION All Rights Reserved BaumFolderCorp., 2015 Printed in U.S.A. TP10669 Warning Do not operate this machine without all guarding in

More information

Passive UTP Transceiver Hub with Integral Camera Power Installation Guide

Passive UTP Transceiver Hub with Integral Camera Power Installation Guide Passive UTP Transceiver Hub with Integral Installation Guide Models Include: HubWay8D HubWay16D - Eight (8) Channels - Sixteen (16) Channels HubWay82D HubWay162D - HubWay8 w/eight (8) HubWayAv - HubWay16

More information

fine-stranded solid V A mm mm V/8 kv/3 32 No AWG 600 V 30/35 No AWG 600 V 40 6 mm 9 mm aüigotucf+qkw h

fine-stranded solid V A mm mm V/8 kv/3 32 No AWG 600 V 30/35 No AWG 600 V 40 6 mm 9 mm aüigotucf+qkw h Terminal blocks with screw connection for junction boxes, type WKI selos BIT EN 60 947-7-1/DIN VDE 0611 T1 UL ratings CSA ratings Width Approvals Feed-through block Feed-through block field-/factory wiring

More information

User Safety. Electrical Safety. Phaser 4500 Laser Printer

User Safety. Electrical Safety. Phaser 4500 Laser Printer User Safety Your printer and the recommended supplies have been designed and tested to meet strict safety requirements. Attention to the following information will ensure the continued safe operation of

More information

Trig Planning Guide. December 2012

Trig Planning Guide. December 2012 Trig Planning Guide December 2012 Table of Contents Statement of Line Trig Applications - Conventional and Integration Specification Information Statement of Line Desks and Work Surfaces Support Options

More information

New 30AA and 31AA Electronic Motor Protection Modules. Application Bulletin 128

New 30AA and 31AA Electronic Motor Protection Modules. Application Bulletin 128 New 30AA and 31AA Electronic Motor Protection Modules Application Bulletin 128 Application Bulletin Number: 128 Release EN: D09910 Date: 4/19/96 Revision EN: Z27301 Date: 10/2/15 Subject: New 30AA and

More information

SAVE THESE INSTRUCTIONS

SAVE THESE INSTRUCTIONS OUTDOOR HARDWIRE INSTALLATION INSTRUCTIONS Please read and save these instructions. Read carefully before using product. Protect yourself and others by observing all safety information, warnings and cautions.

More information

Electrical ELECTRICAL CHOOSE THE RIGHT ELECTRICAL SYSTEM. The Compatico/Byrne systems are UL Listed Manufactured Wiring Systems (UL183).

Electrical ELECTRICAL CHOOSE THE RIGHT ELECTRICAL SYSTEM. The Compatico/Byrne systems are UL Listed Manufactured Wiring Systems (UL183). CHOOSE THE RIGHT ELECTRICAL SYSTEM The Compatico/Byrne systems are UL Listed Manufactured Wiring Systems (UL183). This is important to note because the electrical systems are tested to twice the amperage

More information

DIRECT POWER LIGHTING MANUAL

DIRECT POWER LIGHTING MANUAL SS2 -RGBW RGBW-18L DIRECT POWER LIGHTING MANUAL Coloronix, Inc. 5461 West Jefferson Boulevard Los Angeles, California 90016 (323) 677-4242 http://www.rgbw.com Summary Introduction RGB Color Changing Adjustable

More information

lighting, electrics & communications

lighting, electrics & communications lighting, electrics & communications LIGHTING, ELECTRICS & COMMUNICATIONS OVERVIEW.... 209 LIGHTING BASICS................................. 210 207 MODULAR DESKS APPLICATIONS: 207 POWER & DATA DISTRIBUTION.......................

More information

IntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures)

IntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures) IntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures) Installation and User s Guide IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS TM REPLACEMENT PARTS FOR USE WITH CX SERIES PANELS INSTALLATION INSTRUCTIONS Hubbell Control Solutions 9601 Dessau Road Building One Suite 100 Austin, TX 78754 Toll Free: 888-698-3242 Fax: 512-450-1215

More information

3% VOLTAGE DROP. Installation Instructions for 100 Watt 24 Volt DC RGB DMX LED Power Supply SAVE THESE INSTRUCTIONS!

3% VOLTAGE DROP. Installation Instructions for 100 Watt 24 Volt DC RGB DMX LED Power Supply SAVE THESE INSTRUCTIONS! Doc # 904-PSB-100W--RGB_06 1718 W. Fullerton Chicago, IL 60614 Ph: 773.770.1195 Fax: 773.935.5613 www.pureedgelighting.com info@pureedgelighting.com 2016 PureEdge Lighting. All Rights Reserved. Installation

More information

Assembly Instructions

Assembly Instructions Assembly Instructions MKG_NA-ENG_Instructions_H-line_V16_20170731 But also... for choosing Thank you, Table of Contents GREY YELLOW PINK GREEN PURPLE DARK GREEN LIGHT BLUE ORANGE BLUE Identification of

More information

EMS-LCHW30 & EMS-LCHW50

EMS-LCHW30 & EMS-LCHW50 Electrical Management System (EMS) EMS-LCHW30 & EMS-LCHW50 Installation & Operating Guide for: Model EMS-LCHW30 Rated at 120V/30A and Model EMS-LCHW50 Rated at 240V/50A Surgio Says Lifetime Warranty on

More information

Tarleton State University. Specifications

Tarleton State University. Specifications Tarleton State University Campus Communication Infrastructure Specifications Cabling Standards Summary This document identifies Tarleton State University communication infrastructure standards. The communication

More information

ETM-2040 Service Manual

ETM-2040 Service Manual Introduction Novar s Electronic Thermostat Modules (ETMs) are intelligent control modules that provide local, direct digital control of unitary, packaged, staged HVAC systems. This document: Describes

More information

DS185 1G FS Box Switch Cover. Features. Description. Manufacturer Information EATON CROUSE-HINDS SERIES GTIN

DS185 1G FS Box Switch Cover. Features. Description. Manufacturer Information EATON CROUSE-HINDS SERIES GTIN 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 DS185 1G FS Box Switch Cover Cooper Crouse-Hinds Catalog Number Manufacturer Description Weight per unit Product Category

More information

100/140 Franker Link Unit Operator Manual

100/140 Franker Link Unit Operator Manual Table of Contents SECTION 1 Page 1 Machine specification sheet...3 2 Description of unit...4 3 Machine features...5 4 Machine layout...6 5 Turn plate adjustment...7 Page 1 IMPORTANT NOTICE Before connecting

More information

Table of Contents 1 ABOUT THIS GUIDE CONTACT INFORMATION ANTENNA INSTALLATION... 4

Table of Contents 1 ABOUT THIS GUIDE CONTACT INFORMATION ANTENNA INSTALLATION... 4 Table of Contents 1 ABOUT THIS GUIDE... 3 1.1 CONTACT INFORMATION... 3 2 ANTENNA INSTALLATION... 4 2.1 GENERAL INFORMATION... 4 2.2 SPECIFIC MOUNTING EXAMPLES... 5 2.3 CONNECTOR MOISTURE PROTECTION...

More information

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0 BS 287 DUAL CHANNEL POWER SUPPLY User Manual January 2017 V1.0 Table of contents 1.0 SAFETY INSTRUCTIONS... 3 2.0 GENERAL DESCRIPTION PS 289... 4 3.0 MECHANICAL INSTALLATION... 5 4.0 MAINS POWER & SAFETY

More information

THE CTB08D LIGHT CONTOLLER

THE CTB08D LIGHT CONTOLLER THE CTB08D LIGHT CONTOLLER The CTB08D is a one of the components in the Hobbyist line of Light- O-Rama products. The CTB08D must be used in conjunction with the Light-O-Rama software package. This controller

More information

Next Generation MPR Series

Next Generation MPR Series Next Generation MPR Series modular raceway system design and build a custom power distribution system to your specifications with the MPR series modular power raceway system features: in any position on

More information

ADDENDUM INSTALLATION INSTRUCTIONS. Powered In-Wall Storage Boxes. PAC525FxP2 / PAC526FxP2 / PAC526FxP4 / PAC526FxP6

ADDENDUM INSTALLATION INSTRUCTIONS. Powered In-Wall Storage Boxes. PAC525FxP2 / PAC526FxP2 / PAC526FxP4 / PAC526FxP6 INSTALLATION INSTRUCTIONS ADDENDUM PAC525FxP2 PAC526FxP2 PAC526FxP4 PAC526FxP6 Powered In-Wall Storage Boxes Spanish Product Description German Product Description Portuguese Product Description Italian

More information

This attractive raceway conceals and

This attractive raceway conceals and 5000 Two-Piece Multiple Channel Raceway Access 5000 Nonmetallic Surface Raceway System This attractive raceway conceals and organizes electrical wiring and low-voltage cabling in a sleek, handsome molding.

More information

Basic Principles of Good Electrical Wiring

Basic Principles of Good Electrical Wiring Basic Principles of Good Electrical Wiring Cable.. Wire Cable.. Wire Wire sizes ---- USA --- inside wall For a 20 amp circuit, use 12 gauge wire. For a 15 amp circuit, use 14 gauge wire (in most locales).

More information

IntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures) Installation and User s Guide

IntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures) Installation and User s Guide IntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures) Installation and User s Guide *619751* P/N 619751 - Rev B IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS

More information

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide. .2 Loadcenters and Circuit Breakers Overview Product Selection Guide BR Loadcenters Description Service Single-phase, three-wire, 20/240 Vac Short-Circuit Current Rating 0 kaic: All single- and three-phase

More information

3M Add-On Terminals 4220P (100, 200, 300 & 400 pairs)

3M Add-On Terminals 4220P (100, 200, 300 & 400 pairs) 3M Add-On Terminals 4220P (100, 200, 300 & 400 pairs) Instructions August 2011 3 78-8130-2330-1-C 1.0 General 1.1 The 3M Add-On Terminals 4220P-100, 4220P-200, 4220P-300 and 4220P-400 are designed to expand

More information