Masibus Automation And Instrumentation Pvt. Ltd.
|
|
- Marsha Walker
- 6 years ago
- Views:
Transcription
1 Operator s Manual DIGITAL CONTROLLER 5006H Masibus Automation And Instrumentation Pvt. Ltd. B/30, GIDC Electronics Estate, Sector-25, Gandhinagar , Gujarat, India Ph: Fax: , 82 support@.com Web: Operator s Manual Page 1 of 12
2 CONTENTS 1. GENERAL SPECIFICATIONS 2. MOUNTING DETAIL 3. TERMINAL CONNECTION 4. NAME OF FUNCTION PART AND FUNCTIONS 5. CONFIGURATION MODE 6. RUN MODE 7. CALIBRATION MODE 8. DISCRIPTION FOR RE-TRANSMISSION OUTPUT CALIBRATION 9. COMMUNICATION PROTOCOL Operator s Manual Page 2 of 12
3 1. GENERAL SPECIFICATION MODEL 5006H: Two Set Point and Two Relay output rated for Four Operation Key SET1, SET2, INC and DEC. DISPLAY: 4 digit 0.8" Seven Segment Red LED s for Process Variable Individual discrete Red LED s to indicate relay status. INPUT: RTD - PT100 3-wire (Automatic three wire compensation) Thermo-couple types J, K, T, R, S (ANSI standard) 4-20mA/1-5 V dc linear 0-20mA/0-5 V dc linear INPUT RANGE: PT to 850 ºC PT100 (0.1ºC) to ºC J -100 to 1200 ºC K -100 to 1372 ºC T -100 to 400 ºC R 0 to 1768 ºC S 0 to 1768 ºC 4-20 ma/1-5vdc to 9999 (Field Scalable) 0-20mA/0-5VDC to 9999 (Field Scalable) Digital Zero and Span calibration using front panel keypad. Zero adjustment automatically by software. (Except RTD input) CJC for T/C type input and 3-wire lead compensation for RTD sensor is automatic. TYPES OF SET POINT: Set point types are configurable to energize relays for actual value below or above set point. Hysteresis setting 0 to 100. POWER SUPPLY: 110V/230V 50Hz (Factory set for any one), 24V DC (+/- 10%) (optional) Ambient Temperature: 0 to 55 C Humidity: Up to 95% RH non-condensing Power consumption: Less than 10 VA ACCURACY: ±(0.25% of FS + 1 count) for T/C and RTD input. ±(0.1% of FS + 1 count) for ma and Voltage input OUTPUT (One At Time): Isolated 4-20 ma, 500 Ohms Max. Accuracy: ±0.25% of Full Scale (Digital to analog Only) 30mA TPS. Isolated RS485 Communication. Modbus RTU Protocol CALIBRATION: Operator s Manual Page 3 of 12
4 2. MOUNTING DETAIL FRONT BEZEL: 48 x 96 mm PANEL CUTOUT: 45 x 92 mm DEPTH BEHIND THE PENAL: 163 mm 3. TERMINAL CONNECTION 1. Decrement Key: Decrement value in PV window. 2. Increment Key: Increment value in PV window. 3. PV window: 4 digital SSG LED 0.8 inch RED Display. 4. Relay-1 Indication: Comes ON when relay-1 is energized. 5. Relay-2 Indication: Comes ON when relay-2 is energized. 6. SET-1 key: On pressing this key set value-1 is displayed in PV window. 7. SET-2 key: On pressing this key set value-2 is displayed in PV window. 5. CONFIGURATION MODE Key together to enter configuration mode. PASS WORD Display Pass 0 COnF to configure Input Type, CONFIGURE INPUT TYPE Display InP K.tC InP 4. NAME OF FUNCTIONAL PART AND FUNCTIONS to configure ZERO, CONFIGURE ZERO Display zero -100 ZErO to configure SPAN, CONFIGURE SPAN Display span 1200 span Operator s Manual Page 4 of 12
5 to configure SET POINT1, CONFIGURE SET POINT1 Display TSP1 H on tsp1 to configure SET POINT2, CONFIGURE SET POINT2 Display tsp2 H on tsp2 to configure DP, CONFIGURE DESIMAL POINT Display dp dp to configure Open Sensor, CONFIGURE OPEN SENSOR Display OPE.S UP OPE.S ConF 1200 Up scale: Under Open condition PV is treated above set point. Down scale: Under Open Condition PV is Treated below set point. For Communication Feature following two Parameter (Serial Number and Baud Rate) is add in configuration mode. CONFIGURE SERIAL NUMBER Display SrNO 1 SrNO to configure Baud Rate, CONFIGURE BAUD RATE Display baud 9600 baud to configure Pass Word, CONFIGURE PASS WORD Display PASS 0 PASS ConF 1200 Now you are in run mode and actual PV value on display. 6. RUN MODE To configure set point value, TO SET VALUE OF SET POINT To change Set Point1 Value. TO SET VALUE OF HYSTERISIS 1 Display H 1 > 5 SECOND + To change Hysteresis 1 Value. to configure Serial Number, TO SET VALUE OF SET POINT2 Operator s Manual Page 5 of 12
6 100 CALS + To change Set Point2 Value. TO SET VALUE OF HYSTERISIS 2 Display H 2 > 5 SECOND + To change Hysteresis 2 Value. Note: If Set Point value is less then Zero or more then Span value, the unit will display 'derr' message and will stop control action, keeping all relays in OFF. Reprogramming the unit will overcome this problem. Other wise report to customer support at. 7. CALIBRATION MODE Key together to enter calibration mode. PASS WORD Display Pass 5 COnF CAL to calibrate AMBIENT, CALIBRATION AMBIENT Display CALA 23.8 CALA to calibrate SPAN, CALIBRATION OF SPAN Display CALS 1195 (Adjust req. span value) to calibrate ZERO, CALIBRATION OF ZERO Display CALZ -005 (Adjust req. zero value) CALz Cal 1200 Note: Zero Calibration available only for RTD type input. Now you are in run mode and actual PV value on display. For Re-transmission Feature following Parameter is add in calibration mode. to calibrate OUTPUT ZERO, CALIBRATION OF OUTPUT ZERO Display rtrz (Adjust 4.0mA value) rtrz to calibrate OUTPUT SPAN, CALIBRATION OF OUTPUT SPAN Display rtr 2 and (Adjust 20.0mA value) rtrs Here output sapn display flashings 2 and meen mA. CAL Operator s Manual Page 6 of 12
7 1200 Now you are in run mode and actual PV value on display. 8. DETAIL DESCRIPTION FOR CALIBRATION OF RE-TRANSMISSION OUTPUT. Retransmission output is required to be calibrated at both Zero and Span. Calibration is done at fixed point at 4mA and 20mA. For Retransmission output Calibration go to RTRZ prompt in calibration mode, now press INC or DEC key, this displays the value of current 4mA (4.000 on display) as output. Measure the output current at this point on six times better accurate measuring instrument. Adjust the current value at zero side using increment or decrement key equal to the value as seen on output current measuring unit. Then press SET1 key to enter the value. Repeat the same procedure at the span at RTRS prompt. On RTRS prompt, press INC or DEC key, this displays the value of current equal to 20mA ( with digit 2 flashing). Adjust this value equal to the value as seen on the current measuring unit. Then press SET1 key to enter the value. After entering the current value at the span, the unit under goes one shot Calibration of output. Now the Retransmission output is calibrated. For One shot calibration both zero and span calibration is to be carried out sequentially, one after another in one shot. RTRZ 4.000: Retransmission zero output value 4mA. RTRS (with digit 2 flashing.):- Retransmission Span output value 20mA. Note: Note during calibration of the unit calibrate the ambient only if required. 9. COMMUNICATION PROTOCOL MODBUS-RTU DETAILS INTRODUCTION The unit can be connected in RS-485 communication data link either in multi drop or repeat mode. Each unit must have unique Serial Number. Entire range of addresses (1 to 255) may be used. Before starting any communication, choose a baud rate compatible to the host computer. The serial protocol used is MODBUS RTU. Protocol details: The function codes used Read Write of parameters are: 03. READ HOLDING REGISTERS (REFERENCE - 4x).For Read operation 06. PRESET SINGLE REGISTER (REFERENCE - 4x).For Write operation The error checking field contains a 16-bit value implemented as two eight-bit bytes. The error check value is the result of a Cyclical Redundancy Check (CRC) calculation performed on the message contents. Operator s Manual Page 7 of 12
8 Sr. No. Modbus RTU protocol addresses for RS 485 Communication Analog Parameters Absolute Address Type Access Type 1 PROCESS VALUE Int Read Only 2 SET VALUE Int Read/Write 3 SET VALUE Int Read/Write 4 SET VALUE-1 HYSTERESIS 5 SET VALUE-2 HYSTERESIS Int Read/Write Int Read/Write 6 Engineering Zero Int Read/Write 7 Engineering Span Int Read/Write 8 Input Type Int Read/Write 9 Decimal Position Int Read/Write 10 Set point Type Int Read/Write 11 Set point Type Int Read/Write 12 Set Point Display Int Read/Write NA 13 Open Sensor Status Int Read/Write 14 Serial Number Int Read/Write 15 Baud Rate Int Read/Write 16 Pass Word Int Read/Write Note: NA = Not Applicable. Note: 1) The possible values to be entered through modbus for above parameter s in Table 3 are as follows: a) SET VALUE-1 HYSTERESIS / SET VALUE-2 HYSTERESIS: (Applicable Values: 0 to 100) b) Input Type (Applicable values : 0 to 9): Input Type Value Rtd 0 Rtd.1 1 E-tc (Not Applicable) 2 J-tc 3 K-tc 4 T-tc 5 R-tc 6 S-tc 7 1 5v 8 0 5v 9 Operator s Manual Page 8 of 12
9 c) Decimal Position : Input Type Maximum Value Rtd 0 Rtd.1 0 J-tc 0 K-tc 0 T-tc 0 R-tc 0 S-tc 0 1 5v 3 0 5v 3 d) Set point Type -1 / Set point Type -2 : Type Value L-on 0 h-on 1 e) Set Point Display: Type Value Set point Set point f) Open Sensor Status: Type Value UP 0 DN(down) 1 g) Serial Number : (Applicable Values : 0 to 255) h) Baud Rate : Type (bps) Value i) Pass word: (Applicable Values : 0 to 9999) 9.4: EXCEPTION RESPONCE: CODE MEANING 01 Function code Invalid. It must be 01, 05, 03 or 06.The function code received in the query is not allowable action for the slave. 02 Illegal address value. The data address received in the query is not an allowable address for the salve. Operator s Manual Page 9 of 12
10 03 Illegal data value. A value contained in the query data field is not an allowable value for the salve. 10. Parameter Description: Table 4: Exceptional Response Mode of Operation Description Message Description Conf Configuration Mode inp Input Type rtd RTD Input (1%) Rtd.1 RTD Input (0.1%) J tc J type T/C Input K tc K type T/C Input T tc T type T/C Input R tc R type T/C Input S tc S type T/C Input 1-5V 1-5V Linear Input 0-5V 0-5V Linear Input Zero Zero setting for Span input Span setting for input High type setpoint h-on l-on Low type setpoint Dp Decimal Point Ope.s Open sensor Srno Serial number Baud Baud rate Cal Calibration Mode Rtz1 Zero setting for Retransmission Process Value on PV Window. Rts1 Output Span setting for Retransmission Output Run mode Open * Open Sensor indication Data Error Derr * Table 5: Parameter Description Open * : (1) Sensor at input terminal is not connected or break. (2) Process value is 5% higher than span or lower than zero setting set by user for input type. Operator s Manual Page 10 of 12
11 Derr * : (1) EEPROM is corrupt (2) Set point is greater than zero or span setting. 11. Maintenance: Dangerous voltages capable of causing death are sometimes present in this instrument. Before installation or beginning of any troubleshooting procedures the power to all equipment must be switched off and isolated. Units suspected of being faulty must be disconnected and removed first and brought to a properly equipped workshop for testing and repair. Component replacement and interval adjustments must be made by a company person only. 12. General Problems: Unit does not Switch ON. Check the Mains Cord. I/P power may be not present. Check power supply voltage is it proper as per order. Reading indicated by Unit is unstable, wrong or open. Check the process input and also check its connection are as per the backplate supplied. Check the lead resistance of all the three arms of RTD s. All the three leads should have same lead resistance. If no, change the cables. Check the Input cables are properly tighten with back terminal. Check for AC voltage pick up at the signal terminal. All low-level input and output such as T/C, Rtd, Linear I/P and control signal wires must be kept separate from supply and relay output cabling. Communication Problem between the Unit and Host PC/Operator Terminal. Check the cabling. Check the serial No. and baud rate settings at PC side and controller side. Check the RS-485 to RS232 converter for 485 communication. Check the serial port of the computer by shorting 2 and 3 no pin of PC comports with PROCOMM, Hyper terminal or any other available application. Check RS 232 RS 485 connection at PC and unit side. For RS 485 sometimes terminating resistor of 120Ω at unit side. In most of the cases this is not required for this model. Unit Resetting. Check the proper input terminal connection. If Input Range is 0-5V or 1-5V then maximum voltage should be less than 10V & minimum voltage should be greater than -3V. Supply Voltage. Supply voltage should be given through a good isolation transformer. This being a microprocessor based instrument, a massive voltage spike can damage it. A good isolation transformer shields the instrument from such voltage spikes and surges. All supply connections to final control devices such as contactors, solenoids etc. must be taken directly from the supply and not from the supply terminals of the instrument. Operator s Manual Page 11 of 12
12 This is an electronics instrument it may have problem not listed above, in case of such fault while reporting to factory ( area office or head office), mention exact nature of fault with sequence of events. Operator s Manual Page 12 of 12
Operator s Manual. masibus
Operator s Manual 40005 BARGRAPH INDICATOR DUAL CHANNEL Masibus Automation & Instrumentation Pvt. Ltd. B/30, GIDC Electronics Estate, Sector-25, Gandhinagar-382044, Gujarat, India. Ph: 91-079-23287275/76/77/78/79
More informationmasibus DIGITAL CONTROLLER 5002U Ref No: m55a/om/101 Issue No: 08 Operator s Manual Operator s Manual Page 1 of 20
Operator s Manual DIGITAL CONTROLLER 5002U Operator s Manual Page 1 of 20 CONTENTS 1. TECHNICAL DETAILS 2. SPECIFICATIONS 3. DIMENSIONS & PANEL CUTOUT 4. FRONT FASCIA 5. CONNECTIONS DETAIL 6. USER GUIDE
More informationOPERATIONAL MANUAL FOR 85XX
TECHNICAL DETAILS OPERATIONAL MANUAL FOR 85XX Ref. No. : m83/om/402 This is a versatile microcontroller based Scanner with a very high performance to price ratio. The features offered in this product are
More informationOPERATOR S MANUAL 9000U ISOLATOR
OPERATOR S MANUAL 9000U ISOLATOR Masibus Automation And Instrumentation Pvt. Ltd. B/30, GIDC Electronics Estate, Sector-25, Gandhinagar-382044, Gujarat, India Ph: 91 79 23287275-79 Fax: 91 79 23287281,
More information1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882
1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882 This manual is intended for use in support of installation, commissioning and configuration of the 1/32-DIN Temperature
More informationSINGLE-CHANNEL PROCESS INDICATOR series 8001
SINGLE-CHANNEL PROCESS INDICATOR series 8001 Analog Inputs - all inputs available in one unit - Pt100 RTD type DIN 43 760 or GOST 6651-78 (range from 0 to +600 C) - TC type: J - range from 0 to +600 C
More informationmasibus : UT-94 Page 1 of 6 INTRODUCTION SPECIFICATIONS Dimensions Document Ref No. m98a/om/101 Issue No: 08
INTRODUCTION This is a micro-controller based Universal Transmitter which retransmits the Universal Inputs given, into the required Voltage or current. This instrument provides isolation at 4 levels: (a)
More informationMasibus Automation And Instrumentation Pvt. Ltd.
User Manual 16 CHANNEL DIGITAL INPUT MODULE MASDI DI16 16D Masibus Automation And Instrumentation Pvt. Ltd. B/30, GIDC Electronics Estate, Sector25, Gandhinagar382044, Gujarat, India Phone No : 91 79 23287275
More information9000C INDEX APPLICATION EXAMPLE 1 SPECIFICATION 2 SAFETY AND WARNING... 3 CONNECTION 3 INSTALLATION.. 4 ORDERING CODE 4 TROUBLE SHOOTING 4
Doc.Ref.No.:m92E/om/101 INDEX APPLICATION EXAMPLE 1 SPECIFICATION 2 SAFETY AND WARNING... 3 CONNECTION 3 INSTALLATION.. 4 ORDERING CODE 4 TROUBLE SHOOTING 4 ISOLATED CONVERTER 9000C SERIES 9000C Series
More informationUDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS
UDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS EN0I-6041 12/99 PRODUCT SPECIFICATION SHEET OVERVIEW The UDC 1000 and UDC 1500 are microprocessor-based 1/16 DIN and 1/8 DIN controllers
More information/8 DIN Universal Process Indicator
Data Sheet SS/_ High visibility LED display the clearest view of your process status.% measurement accuracy precise indication of process measurement Analog and relay outputs as standard alarm and retransmission
More informationR1M-GH THERMOCOUPLE & DC INPUT MODULE MODEL. Remote I/O R1M Series. (16 points)
Remote I/O R1M Series THERMOCOUPLE & DC INPUT MODULE (16 points) MODEL MODEL & SUFFIX CODE SELECTION R1MGH2T MODEL Modbus protocol I/O TYPE GH2 : Thermocouple or DC input, 16 points FIELD TERMINAL TYPE
More information12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)
4-20 ma & Relay Output Features 4-20 ma, ± 10 V, TC & RTD Inputs 12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm) 24 VDC @ 200 ma Transmitter Power Supply Options Type
More informationDigital Indicating Controllers. JC Series. High performance controllers...at the lowest prices anywhere! Toll Free
Digital Indicating Controllers JC Series High performance controllers...at the lowest prices anywhere! www.mod-tronic.com Toll Free 1-800 794-5883 Standard Features Structure Units available in standard
More informationWall-/Pipe Mounted Universal Process Indicator
Data Sheet SS/_8 Wall-/Pipe Mounted Universal Process Indicator High visibility LED display the clearest view of your process status 0.1% measurement accuracy precise indication of process measurement
More informationLD-RTD / LD-TC Temperature Controller
1 LD-RTD / LD-TC Temperature Controller Available in either an RTD model or a thermocouple model, these units accept all common temperature probe types, and offer a technically advanced, but cost effective
More informationTrident and Trident X2 Digital Process and Temperature Panel Meter
Sign In New User ISO 9001:2008 Certified Quality System Home Products Online Tools Videos Downloads About Us Store Contact Policies Trident and Trident X2 Digital Process and Temperature Panel Meter Products
More informationC160 Wall-/Pipe Mounted Universal Process Indicator
Data sheet DS/ EN Rev. I Wall-/Pipe Mounted Universal Process Indicator reliable process indicator, wherever it s needed High visibility LED display the clearest view of your process status 0.1% measurement
More informationTempco Instruction Manual
Tempco Instruction Manual 1/16 DIN Solid State Temperature Controller Relay Output Solid State Output For Heating Model Numbers: TEC-901, TEC-902, TEC-905 Temperature controls in this series are designed
More information2 Table of Contents 1. TABLE OF CONTENTS. 1. Table of Contents Introduction Wiring Diagram Terminals Review...
TPR-6 Temperature Protection Relay Instruction Manual Ver. June 1 st 2010 2 Table of Contents 1. TABLE OF CONTENTS 1. Table of Contents... 2 2. Introduction... 3 3. Wiring Diagram... 5 4. Terminals Review...
More informationUNIVERSAL PROCESS INDICATOR / CONTROLLER Model No. : UT-102
OPERATION MANUAL UNIVERSAL PROCESS INDICATOR / CONTROLLER Model No. : UT-102 AL-1 AL-2 AL-3 AL-4 UNIVERSAL INDICATOR/CONTROLLER INTRODUCTION FRONT PANEL DESCRIPTION TECHNICAL SPECIFICATION INSTALLATION
More informationABB Instrumentation. Specification DataFile COMMANDER 100. the-easy-to use 1. /8 DIN controller with extensive application capabilities
COMMANDER Universal Process Controller Specification DataFile PID controller with one shot autotune single loop, heat/cool and ramp/soak as standard Quick code, front face or PC configuration easy commissioning
More information4511 MODBUS RTU. Configuration Manual. Universal transmitter. No. 4116MCM101(1445) For 4511 devices from ser. no:
4511 MODBUS RTU Configuration Manual 4116 Universal transmitter 4116MCM101(1445) For 4511 devices from ser. no: 141590001 4116 CONTENTS Introduction... 1 Modbus basics... 1 Modbus RTU... 1 4511 Supported
More informationPD765 TRIDENT. Trident Series Process & Temperature Meters.
PD765 Trident Series Process & Temperature Meters TRIDENT PROCESS & Temp 4-20 ma, ± 10 V, TC & RTD Inputs 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm) Type 4X, NEMA 4X, IP65 Front 1/8 DIN Shallow
More information- SELF-TUNING PID ALGORITHM - INTUITIVE COLOR DISPLAY WITH TEXT MESSAGING - UNIVERSAL PROCESS AND TC/RTD INPUTS - MULTI- FUNCTION RAMP- DWELL/PROCESS
ELK. ETK COMPACT BASIC CONTROL - SELF-TUNING PID ALGORITHM - INTUITIVE COLOR DISPLAY WITH TEXT MESSAGING - UNIVERSAL PROCESS AND TC/RTD INPUTS - MULTI- FUNCTION RAMP- DWELL/PROCESS TIMER - SOFT START OUTPUT
More information4511 MODBUS RTU. Configuration Manual. Universal trip amplifier. No. 4131MCM100(1402)
4511 MODBUS RTU Configuration Manual 4131 Universal trip amplifier 4131MCM100(1402) 4131 CONTENTS Introduction... 3 Modbus basics... 3 Modbus RTU... 3 Supported Function Codes... 3 Modbus Parameters and
More information4511 MODBUS RTU. Configuration Manual. Universal trip amplifier. No. 4131MCM101(1445) For 4511 devices from ser. no:
4511 MODBUS RTU Configuration Manual 4131 Universal trip amplifier 4131MCM101(1445) For 4511 devices from ser. no: 141590001 4131 CONTENTS Introduction... 1 Modbus basics... 1 Modbus RTU... 1 4511 Supported
More informationCHAPTER 1. Introduction Introduction 3
Technical & User Manual Weight Indicator: SMIT-3015 Manufactured By: Samyak Instrumentation Pvt.Ltd. F-4, Memnagar Complex, Opp.Petrol Pump, Memnagar Village, Ahmedabad, India-380052. Phone: +91-79-27495500/5600,
More informationPD765 TRIDENT. Trident Series Process & Temperature Meters.
PD765 Trident Series Process & Temperature Meters TRIDENT PROCESS & Temp 4-20 ma, ± 10 V, TC & RTD Inputs 4-Digit Display, 0.56" (14.2 mm) or 1.20" (30.5 mm) Linear or Square Root with Low-Flow Cutoff
More informationThe PM1000 series is a universal 4 digit LED plug-on display for transmitters with 4-20mA 2 wire output and fitted with DIN43650 connector.
PM1000 SERIES PLUG-ON DISPLAY BRIGHT LED DISPLAY INDICATION RANGE -999 TO +9999 FITS TO DIN 43650 CONNECTOR PLUG-ON TO ANY TRANSMITTER WITH 4-20MA OUTPUT EASY TO SCALE ON SITE ROBUST DESIGN SET POINT OPTION
More informationTRACKER 220 SERIES. Digital Panel Indicators. A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement
TRACKER 220 SERIES Digital Panel Indicators A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement TRACKER 220 SERIES INDICATORS Universal Input Analogue Output
More informationThe Tracker 220 Series A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement
Acquisition Measurement Control The Tracker 220 Series A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement TRACKER 220 SERIES INDICATORS Universal Input
More information/8 DIN Motorized Valve Controller
Data Sheet SS/_5 Boundless motorized valve controller no need for slidewire feedback; improves reliability Two sealed 5A control relays suitable for direct connection to the valve, reducing installation
More information4511 MODBUS RTU. Configuration Manual. Universal transmitter. No. 4114MCM100(1402)
4511 MODBUS RTU Configuration Manual 4114 Universal transmitter 4114MCM100(1402) 4114 CONTENTS Introduction... 3 Modbus basics... 3 Modbus RTU... 3 Supported Function Codes... 3 Modbus Parameters and factory
More informationThe IQ240 panel mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.
IQ240 Panel Mount Load Cell Indicator Data sheet English 1.01 Introduction The IQ240 panel mount load cell indicator is a precision digital indicator for load cell and strain gauge applications. The high
More information4511 MODBUS RTU. Configuration Manual. Universal transmitter. No. 4114MCM101(1445) For 4511 devices from ser. no:
4511 MODBUS RTU Configuration Manual 4114 Universal transmitter 4114MCM101(1445) For 4511 devices from ser. no: 141590001 4114 CONTENTS Introduction... 3 Modbus basics...3 Modbus RTU...3 4511 Supported
More informationRTD Temperature acquisition converter WJ25
8-CH Thermocouple Signal to RS485/232 Acquisition Converter (WJ27 series 24Bits A/D Converter, data acquisition) Features: >> Eight channels thermocouple signal acquisition, isolated converter RS-485/232
More informationUser s manual. Programmable panel meter IPD
User s manual Programmable panel meter IPD Assembly Wall assembly: +0,5 +0,2 Window of 46 x 91 mm (2.5" x 3.5" ) Made with ABS (UL94-HB) -0-0 General cares in the installation The equipments must not be
More informationD7000 SERIES MODBUS TCP/IP ETHERNET INTERFACE MODULES
11/17 D7000 SERIES MODBUS TCP/IP ETHERNET INTERFACE MODULES D7000 FEATURES Complete data acquisition systems. Analog and Digital I/O models available. RJ-45 Ethernet 10/100MB interface. Modbus TCP/IP Ethernet
More informationHigh Voltage DC Meter
High Voltage DC Meter Javelin D PD644 0-300 VDC input NEMA 4X, IP65 front Scale in engineering units Sunlight readable LED display 4-20 ma analog output Two form C 3 A relays option RS-485 serial communications
More informationHIGH-VOLTAGE DC METER
HIGH-VOLTAGE DC METER Javelin D PD644 0-300 VDC input NEMA 4X, IP65 front Scale in engineering units Sunlight readable LED display 4-20 ma analog output Two form C 3 A relays option RS-485 serial communications
More informationLAUREL ELECTRONICS, INC.
LAUREL ELECTRONICS, INC. Laureate RTD Temperature Panel Meter / Controller Features Factory calibrated for 100Ω platinum, 10Ω copper & 120Ω nickel RTDs 2, 3 or 4-wire connection with lead resistance compensation
More informationMODCELL 2050R Single Loop Controllers
Isolated universal process and remote set-point input Four internal set-points No jumpers required to define instrument parameters Ratio/bias on process and remote set-point Totalizer Ramp/soak profile
More informationWSK INTELLIGENT TEMPERATURE AND HUMIDITY CONTROLLER USER MANUAL
WSK INTELLIGENT TEMPERATURE AND HUMIDITY CONTROLLER USER MANUAL WSK INTELLIGENT TEMPERATURE AND HUMIDITY CONTROLLER USER MANUAL v 1.0 Thanks for choosing the Intelligent temperature and humidity controller
More informationSmall distributed I/O module
MLIO Summary Application Function Small distributed I/O module Small I/O module MLIO is a microprocessor-controlled, communiccative module for installation outside the control panel. It is used for topologies
More informationNeon pr. ph/ ORP measurement. Applications. Description
Easy handling by graphical menue Fitting for your application by modular setup Simple firmware update and configuration using SD-card Applications Process Water Drinking Water / Beverages Waste Water Treatment
More informationUDC1200 and UDC1700 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS
UDC1200 and UDC1700 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS 51-52-03-35 11/06 PRODUCT SPECIFICATION SHEET OVERVIEW The UDC1200 & UDC1700 are microprocessor-based 1/16 DIN and 1/8 DIN controllers
More informationMRC 7000 Proven Recording Reliability that Became the Industry Standard!
Data Sheet Recorder//Profiler DESCRIPTION The MRC7000 Recorder/ is a microprocessor based circular chart instrument capable of measuring, displaying, recording and controlling up to two process variables
More informationLAUREL. Laureate RTD Temperature Panel Meter / Controller ELECTRONICS, INC. Features. Description. Specifications
LAUREL ELECTRONICS, INC. Laureate RTD Temperature Panel Meter / Controller Features Factory calibrated for 100Ω platinum, 10Ω copper & 120Ω nickel RTDs 2, 3 or 4-wire connection with lead resistance compensation
More informationUniversal power supply
Honeywell UDC1200 and UDC1700 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS 51-52-03-35 5/03 PRODUCT SPECIFICATION SHEET OVERVIEW The UDC1200 & UDC1700 are microprocessor-based 1/16 DIN and 1/8 DIN controllers,
More informationOperating Manual. Dynisco /8 DIN Indicator Concise Product Manual
Dynisco 1490 1/8 DIN Indicator Concise Product Manual 59476-9 Operating Manual -1- CAUTION: Installation should be only performed by technically competent personnel. Local Regulations regarding electrical
More informationIntech Micro 2300-RTD6 analogue input station MODBUS RTU slave application supplementary manual.
Intech Micro 2300-RTD6 analogue input station MODBUS RTU slave application supplementary manual. MODBUS supplementary manual to the 2300-RTD6 Installation Guide. The 2300 series stations are designed to
More informationProcess displays For current and voltage
Features Voltage input TRMS-AC/DC up to 600 V Current input AC/DC 1 A, 5 A and shunt (precision resistor) 60 or 100 mv With 2 or 4 limits Display range can be linearised Min, Max, Hold functions 4 20 ma
More informationSX90 Process Controller
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More informationINSTRUCTION MANUAL STATION CONTROLLER SC1000 MOTOR PROTECTION ELECTRONICS, INC.
INSTRUCTION MANUAL STATION CONTROLLER SC1000 MOTOR PROTECTION ELECTRONICS, INC. 2464 Vulcan Road, Apopka, Florida 32703 Phone: (407) 299-3825 Fax: (407) 294-9435 Revision Date: 9-11-08 Applications: Simplex,
More informationStandard Options. Model 4100 Position Indicating Meter. Three Phase Motor Control. Positran Transmitter
Standard Options Model 4100 Position Indicating Meter A percent-of-full-travel meter is supplied with a trim potentiometer resistor, terminal block and connectors. A potentiometer is required in the actuator
More informationJUMO Quantum PID100/PID200/PID300
Data sheet 702020 Page 1/12 JUMO Quantum PID100/PID200/PID300 Universal PID Controller Series Brief description The Quantum series is available in the three DIN formats 48 mm x 48 mm, 48 mm x 96 mm, and
More information3690 N.W. 53rd Street Fort Lauderdale, FL SC-2124 SC-2124M. 24 Channel Universal Scanner. Installation and Operation Manual P/N 145F-11902
3690 N.W. 53rd Street Fort Lauderdale, FL 33309 SC-2124 SC-2124M 24 Channel Universal Scanner Installation and Operation Manual P/N 145F-11902 Rev. 3.30 (c) Copyright 2000, Dynalco Controls All Rights
More informationNetBiter I/O Extender User Manual
User Manual Part no. 0920-9999-009 IntelliCom Innovation AB Pilefeltsgatan 73 SE-302 50 Halmstad SWEDEN Phone +46 35 17 29 90 Fax +46 35 17 29 09 email info@intellicom.se www www.intellicom.se Revision
More informationGetting Started with your D3000M Series Module
Getting Started with your D3000M Series Module This document contains step-by-step instructions to quickly connect and communicate with your D3000M modules. The modules require a one-time configuration
More informationSED2 Variable Frequency Drives with Electronic (E) Bypass Options
SED2 Variable Frequency Drives with Electronic (E) Options Description The E- Options are companion packages for the family of SED2 Variable Frequency Drives (s). For information on the family of SED2
More informationInterface Definition RISH EM 2340/1320/30/ _Rev. D - 8/2016
Interface Definition RISH EM 2340/1320/30/40 1 2-60-006-00-00494_Rev. D - 8/2016 2 Section DIGITAL MULTIFUNCTION INSTRUMENT Contents 1. Introduction Programmable Multi-function Energy Meter Installation
More informationCole-Parmer Instrument Company
Operating Instructions Cole-Parmer ph/orp 400 ph/orp Controller Cole-Parmer Instrument Company 625 East Bunker Court, Vernon Hills, Illinois 60061 Tel: 1-847-549-7600 or Toll-free: 1-800-323-4340 Fax:
More informationD1000M SERIES FOR MODBUS SENSOR TO COMPUTER INTERFACE MODULES
D1000M SERIES FOR MODBUS SENSOR TO COMPUTER INTERFACE MODULES D1000 FEATURES Complete sensor to RS-232/RS-485 interface. 500V rms analog input isolation. 15 bit measurement resolution. Continuous self-calibration;
More informationMTII4200 Level Transmitter Installation, Operation & Maintenance Instructions
Specialists in Liquid Level Indication MTII4200 Level Transmitter Installation, Operation & Maintenance Instructions Section: M500 Bulletin: M500.31 Date: 05-17-16 Supersedes: 09-30-11 1. INTRODUCTION
More informationOperating Guide MODBUS (RTU) Communications Option IM/L150 MOD_2. Level Indicator L150 and L160
Operating Guide MODBUS (RTU) Communications Option IM/L150 MOD_2 Level Indicator L150 and L160 Electrical Safety This equipment complies with the requirements of CEI/IEC 61010-1:2001-2 "Safety requirements
More informationPanel Meter Model PM6-RT Temperature Display Operation and Instruction Manual
Panel Meter Model PM6-RT Temperature Display Operation and Instruction Manual AMALGAMATED INSTRUMENT CO ABN: 80 619 963 692 Unit 5, 28 Leighton Place Hornsby Telephone: +61 2 9476 2244 e-mail: sales@aicpl.com.au
More informationECAN-240. (Modbus TCP to 2-port CAN Bus Gateway User manual) ECAN-240 Modbus TCP to 2-port CAN Bus Gateway User Manual, Version 1.0.
ECAN-240 (Modbus TCP to 2-port CAN Bus Gateway User manual) ECAN-240 Modbus TCP to 2-port CAN Bus Gateway User Manual, Version 1.0.0 Page: 1 Table of Contents Table of Contents -----------------------------------------------------------------------------2
More informationIntech Micro 2300-A8VI analogue input station MODBUS RTU slave application supplementary manual.
Intech Micro 2300-A8VI analogue input station MODBUS RTU slave application supplementary manual. MODBUS supplementary manual to the 2300-A8VI Installation Guide. The 2300 series stations are designed to
More informationModbus on K45 asense. Table of contents:
Modbus on K45 asense Table of contents: 1. General.... Byte transmission.... 3. Serial line frame and addressing.... 4 4. Bus timing.... 4 5. Modbus registers on sensor.... 5 6. Supported Modbus commands...
More informationQuantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III
Compact DC Drive Package The delivers a DC drive package that integrates the intelligence of the Mentor II with a space saving design that incorporates many accessories typically required in the North
More informationTHM501 PT100 MODBUS TEMPERATURE TRANSMITTER
THM501 PT100 MODBUS TEMPERATURE TRANSMITTER INTRODUCTION The TekOn Electronics In Head 2-Wire Temperature Transmitters are specifically designed to meet the most rigorous requirements of operation in the
More informationInstallation and Operation Manual. INTEGRA BTU Meter System
INTEGRA BTU Meter System Meter 1/4 Supply Temp. [F] 79.71 Return Temp. [F] 79.47 Flow [gal/min] 20.00 Energy Rate [kbtu/h] 2.84 Energy Total [kbtu] 646147 ß á à Overview Meter 1 Total [kbtu] 646147 Meter
More informationAnalog signal to RS485 or RS232 Converter, A/D Converter
Analog signal to RS485 or RS232 Converter, A/D Converter Features: Analog signal acquisition, isolated RS-485/232 output 12-bit AD converter, testing accuracy>0.1% Can be remotely reconfigured for modules
More informationWireless Transducer MOTOR PROTECTION ELECTRONICS, INC. INSTRUCTION MANUAL. (407) Phone: Website:
Wireless Transducer INSTRUCTION MANUAL MOTOR PROTECTION ELECTRONICS, INC. 2464 Vulcan Road Apopka, Florida 32703 Phone: Website: (407) 299-3825 www.mpelectronics.com Operating Program Revision: 2 Revision
More informationinstallation Operation ADDRESS product diagram H8030/8031 INSTALLATION GUIDE
POWER MONITORING INSTALLATION GUIDE H8030/8031 H8030/8031 Modbus Energy Meter Networked kw/kwh Transducer Product Identification Model Max Amps CT Size Enhanced Data Stream Meters H8030-0100- 100 H8030-0300-
More informationH3 Series. Nanmac Corporation. Dual-Line 6-Digit Temperature Meter.
H3 Series Dual-Line 6-Digit Temperature Meter Temperature J, K, T, E, R, S, B, N, C Thermocouples 100 or 1000 Ω Platinum, 10 Ω Copper, 120 Ω Nickel RTDs 1 or 0.1 Resolution Averages up to 10 RTD Sensors
More informationPRO-RTD Temperature Controller
PRO-RTD Temperature Controller 1 This quad channel RTD controller is ideal for numerous industrial temperature applications. It accepts direct sensor input from RTD 385, 392 and CU10 temperature probes.
More informationINTELLIS. Modbus Direct Network Monitor
INTELLIS Modbus Direct Network Monitor System Installation and Operation Manual Phone: (201) 794-7650 Fax: (201)794-0913 Chapter 1 Modbus Protocol Revision History Revision 1.0 30 April, 2002 Initial Version
More informationDXTH DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY. Mounting and operating instructions
DUAL DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL
More informationSignal Isolators & Conditioners
Analog Signal to RS485/232 Converter Signal Isolators & Conditioners (WJ21 series A/D Converter) Features: >> Analog signal acquisition, isolated RS-485/232 output >> 12-bit AD converter, testing accuracy>0.1%
More informationThe IQ300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.
IQ300 Wall Mount Load Cell Indicator Data sheet English 1.01 Introduction The IQ300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications. The high
More informationOperation Manual CX10 1/8 DIN Microcomputer Based Conductivity/Resistivity Controller
Operation Manual CX10 1/8 DIN Microcomputer Based Conductivity/Resistivity Controller 11751 Markon Drive Garden Grove, CA. 92841 U.S.A. pg. 1 CONTENTS GENERAL INTRODUCTION.....3 INITIAL INSPECTION......3
More informationDMW. Digital Weighing Meter. Model Number Legend SALIENT FEATURES. Sensing
Digital Meter Model Number Legend 1 2 3 1. Series 2. Output Type N: Indication Only R: 2 Relay Output M: 2 Relay Output + RS485 Modbus SALIENT FEATURES External Tare 96 x 48 Housing Dual Alarm Outputs
More informationUser Guide IM/C250 MOD_3. Modbus (RTU) Communications Option C250 and V250
User Guide IM/C250 MOD_3 Modbus (RTU) Communications Option C250 and V250 Electrical Safety This instrument complies with the requirements of CEI/IEC 61010-1:2001-2 "Safety requirements for electrical
More information2. Terminal arrangement TEMPERATURE CONTROLLER KT2 COMMUNICATION INSTRUCTION MANUAL. (Fig. 2-1)
COMMUNICATION INSTRUCTION MANUAL TEMPERATURE CONTROLLER No.KTC3E2 2006.08 To prevent accidents arising from the misuse of this controller, please ensure the operator receives this manual. For this product
More informationKTC. Preset Counter/ Timer. Programmable Type. Model Number Legend SALIENT FEATURES. Sensing. Digital Panel Meters
Preset Counter/ Timer Programmable Type Model Number Legend SALIENT FEATURES 6 Digits PV, SV Universal Input Dual alarm output MODBUS via RS-485 High Speed - 10 KCPS Multiple output modes Batch Counting,
More informationOPERATING MANUAL FOR STREAM SELECTOR
OPERATING MANUAL FOR STREAM SELECTOR Manufactured By: INSTRUMENTATION PVT. LTD. F-4 Memnagar complex, Opp. Petrol Pump Memnagar, Ahmedabad, India-380 052 Phone: +91-79-2749 5500/5600 FAX: +91-79-27417997
More informationSignal Isolators & Conditioners
WJ21 series Analog Signal to RS485/232 Converter (A/D Converter) Features: >> Analog signal acquisition, isolated RS-485/232 output >> 12-bit AD converter, testing accuracy>0.1% >> Can Program and calibrate
More informationPT2060 Monitor. PT2060/91 SIM System Interface Module. Specifications. Electrical. Messtechnik
PT2060/ System Interface Module ProvibTech s PT2060/ module is a communication and system interface module. This module is used to: module. The two phase reference channels can be used to provide phase
More informationAMC 8 & IOC 8T. Analog Monitoring Card Type AMC 8 and Input / Output Card Type IOC 8T FEATURES
Analog Monitoring Card Type AMC 8 and Input / Output Card Type IOC 8T FEATURES Two cards providing 8 channels of temperature and process monitoring for VM 600 systems 8 channels of software selectable
More informationSE-135 MANUAL GROUND-FAULT GROUND-CHECK MONITOR
SE-135 MANUAL GROUND-FAULT GROUND-CHECK MONITOR AUGUST 14, 2001 REVISION 1 Publication: SE-135-M Document: S95-C135-00000 Printed in Canada. Copyright 2001 by Startco Engineering Ltd. All rights reserved.
More informationBasic Temperature and Limit Controllers
Basic Temperature and Limit Controllers Basic Temperature and Limit Controller Provide Economical Solution for a Wide Range of Applications The basic and limit microprocessor-based controllers from Watlow
More information4511 MODBUS RTU. Configuration Manual. Pulse isolator. No. 9202MCM101(1707) For 4511 devices from ser. no:
4511 MODBUS RTU Configuration Manual Pulse isolator No. 9202MCM101(1707) For 4511 devices from ser. no: 141590001 9202 CONTENTS Introduction...3 Modbus basics...3 Modbus RTU...3 4511 Supported Modbus Function
More informationBasic Temperature and Limit Controllers. Provide Economical Solution for a Wide Range of Applications SPECIFICATION SHEET
SPECIFICATION SHEET Basic Temperature and Limit Controllers Basic Temperature and Limit Controllers Provide Economical Solution for a Wide Range of Applications The basic and limit microprocessor-based
More informationD115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors
D115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors Ron Boe 5/15/2014 This user guide details the servo drives capabilities and physical interfaces. Users will be able to
More informationOperation Manual TX10 1/8 DIN Microcomputer Based ph/orp Controller
Operation Manual TX10 1/8 DIN Microcomputer Based /ORP Controller 11751 Markon Drive Garden Grove, CA. 92841 U.S.A. pg. 1 CONTENTS GENERAL INTRODUCTION.....3 INITIAL INSPECTION......3 USING THE Sensorex
More informationMDA-8000 DIO User Manual
MDA-8000 DIO User Manual Warranty All products manufactured by Maxthermo-Gitta are under warranty regarding defective materials for a period of one year from the date of delivery to the original purchaser.
More informationSetpoint adjuster SG 9648 Output standard signals 0/ ma or 0/ V DC
adjuster SG 9648 Output standard signals 0/4... 20 ma or 0/2... 10 V DC Features M LEDDisplay 14.2 mm red M Display range ± 9999(0) digit M Indicating range and decimal point free programmable M Set point
More informationEnvironmental Chamber Programmer/Controller
Environmental Chamber Programmer/Controller Complete Single, Dual or Three Channel Control System. or - Patented FastTRAC Part Temperature Control. or FastTRAC Control Plus Second Channel for Vibration,
More information