1 Innovative POWER Solutions ISO 9001 : 2008 REGISTERED QUALITY MANAGEMENT SYSTEM PANTROL, INC. INVITES YOU TO REVIEW A SAMPLING OF OUR STANDARD PRODUCTS LINE. FOR SPECIAL APPLICATIONS OR CONFIGURATIONS PLEASE CALL OUR SALES STAFF E. Ferry Ave, Spokane, WA Phone Fax or

2 Power Transfer Cabinet Features & Options The Pantrol Power Transfer Cabinet ( PTC) integrates service disconnect, transfer switch, load center and surge protection in a cost effective value added product. Power Transfer Cabinet Features 891 Listed, Dead-Front Switchboards Indoor or Outdoor, Steel or Aluminum Dimensions: Reference available cabinets Three Point Latching, Pad Lockable Door Handle Suitable for Use as Service Equipment N-G Bonding Kit Included Powder Coat Finish Voltage: 120/240V, Three-Wire and Ground Amperage: 100A, 200/100, or 200A Load Center: Square D, 200A, QO Series Optional 12, 24, 30 or 42 Position kaic Rating: Utility Up to 65kAIC Service Disconnect/Transfer Options: Single Source-Single Main Power Transfer Cabinet Options Generator Receptacle: Customer Specified Generator Receptacle Mounting: Horizontal, Vertical, 45 degrees, Left or Right Mount PanLoc and PanLoc Lite: Single Pole Connectors Surge Protection Devices: Call for options Monitoring: NO/NC Utility and/or Generator Voltage Monitoring TVSS Monitoring Door Alarm Contacts Other: Multiple mounting options and accessories available Telco Equipment Cabinets: Wall Mount, Pad Mount Two Source-Manual Transfer Automatic Transfer Switch

3 Power Transfer and Telco Equipment Cabinets Standard AC Cabinet Size and NEMA Rating 40hX20wX10d NEMA 3R 40hX20wX10d NEMA 3R/PED/DOOR 40hX20wX10d NEMA 3R/PED 59hX24wX10d NEMA 3R 60hX25wX10d HYBRID NEMA 3R 60hX29wX10d NEMA 3R 47hX24wX6d NEMA 1 60hX29wX6d NEMA 1 Standard Telco Equipment Cabinets 18hx18wx8d NEMA 3R 39hx20wx20d Equipment Cab NEMA 3R 40hX20wX10d NEMA 3R (shown w/ptc) 59hX24wX10d NEMA 3R (shown w/ptc) 59hX24wX20d NEMA 3R AXT Environmentally Controlled Cabinet Rack mount Power Distribution PanLoc and PanLoc Lite Universal Connection for Alternate Power Source **Other sizes and rating available please call for details.

4 Power Transfer Cabinet 40h X 20w X 10d Type 3R Power Transfer Cabinets Features/Options UL 891 Dead Front Switchboard Listed Suitable For Use As Service Equipment N-G Bonding kit included Voltage: 240/120 Single Phase Three Wire and Ground Amperage: 100A or 200A kaic Rating: Up to 65,000 amps Single Disconnect or Manual Transfer Switch Load Center: 24 or 30 Position NO/NC Utility and/or Generator Voltage Monitoring Generator Receptacle or PanLoc Convenient Knockout locations Receptacles (GFI, Duplex, etc.) NEMA 3R Aluminum Construction 3 point latching/pad lockable door handle Silkscreen, Hinged/Lift off Dead-Front Captive Dead-Front Fasteners Dimensions 40 h x 20 w x 10 d

5 Power Transfer Cabinet 40h X 20w X 10d Type 3R and Pedestal W/Door Power Transfer Cabinet Features Reference 40 h x 20 w x 10 d Power Transfer Cabinet Telco Pedestal Features/Options Standard or Flame Retardant Plywood LED Lighting Door Alarm Contacts Receptacles (GFI, Duplex, etc.) Buss Bar (size/type optional) Punch Down Block Single Point Latching/Pad Lockable Door Handle NEMA 3R, Aluminum Construction Dimensions 21 h x 20 w x 10 d

6 Power Transfer Cabinet 40h X 20w X 10d Type 3R with Standard Pedestal Power Transfer Cabinet Features Reference 40 h x 20 w x 10 d Power Transfer Cabinet Mounting Pedestal Features Aluminum Construction Side Knock Outs Front Access Panel Dimensions 21 h x 20 w x 10 d Contact a Pantrol Inc. Sales Representative for configuration

7 Telco Equipment Cabinet 40h X 20w X 10d Type 3R Features/Options UL Listed Door Louvers w/filter Aluminum frame re-usable electrostatic filters Three point door latching Pad Lockable Door Handle AC or DC Fan Air Conditioner (Size/Type optional) Receptacles (GFI, Duplex etc.) Standard or Flame Retardant Plywood Equipment Rails Equipment Rack (Swing Down) Fold Down Shelf Insulation Pedestal / Wire Way LED Lighting Door Alarm Contacts Ground Bar (size/type optional) Punch Down Block NEMA 3R, Aluminum Construction Dimensions 40 h x 20 w x 10 d

8 Power Transfer Cabinet 59h X 24w X 10d Type 3R Power Transfer Cabinet Features/Options UL 891 Dead Front Switchboard Listed Suitable for Use as Service Equipment N-G Bonding kit included Voltage: 240/120 Single Phase Three Wire and Ground Amperage: 100A or 200A kaic Rating: Up to 65,000 amps Single Disconnect, Manual Transfer Switch or Automatic Transfer Switch Load Center: 24, 30 or 42 Position Generator Receptacle or PanLoc NO/NC Utility and/or Generator Voltage Monitoring Convenience Receptacle: GFI 15 amp Duplex Silkscreen, Hinged/Lift off Dead-Front 3 point latching/pad lockable door handle Door Wind Stop NEMA 3R, Aluminum Construction Dimensions 59 h x 24 w x 10 d

9 Telco Equipment Cabinet 59h X 24w X 10d Type 3R Features/Options UL Listed Door Louvers w/filter Aluminum frame re-usable electrostatic filters Three point door latching Pad Lockable Door Handle AC or DC Fan Air Conditioner (size/type optional) Receptacles (GFI, Duplex etc.) Standard or Flame Retardant Plywood Equipment Rails Equipment Rack (Swing Down) Fold Down Shelf Insulation Pedestal / Wire Way LED Lighting Door Alarm Contacts Ground Bar (size/type optional) Punch Down Block Door Wind Stop NEMA 3R, Aluminum Construction Dimensions 59 h x 24 w x 10 d

10 Power Transfer Cabinet 60h X 25w X 10d Hybrid Type 3R Power Transfer Cabinet Features/Options UL 891 Dead Front Switchboard Listed Suitable for Use as Service Equipment N-G Bonding kit included Voltage: 240/120 Single Phase Three Wire and Ground Amperage: 100A or 200A kaic Rating: Up to 65,000 amps Generator Receptacle or PanLoc Single Disconnect or Manual Transfer Switch Load Center: 24, 30 or 42 Position NO/NC Utility and/or Generator Voltage Monitoring Convenience Receptacle: GFI 15 amp Duplex Silkscreen, Hinged/Lift off Dead-Front 3 point latching/pad lockable door handle Door Wind Stop Captive Dead-Front Fasteners NEMA 3R, Aluminum Construction Dimensions 30 h x 25 w x 10 d Telco Equipment Section Features/Options Standard or Flame Retardant Plywood GFI 15 Amp Duplex Receptacle AC or DC Fan Aluminum frame re-usable electrostatic filters LED Lighting Punch Down Block Ground Bar (size/type optional) Dimensions 30 h x 25 w x 10 d

11 Power Transfer Cabinet 60h X 29w X 10d Type 3R Power Transfer Cabinet Features/Options UL 891 Dead Front Switchboard Listed Suitable for Use as Service Equipment N-G Bonding kit included Voltage: 240/120 Single Phase Three Wire and Ground Amperage: 100A or 200A kaic Rating: Up to 65,000 amps NO/NC Utility and/or Generator Voltage Monitoring Automatic Transfer Switch or Manual Transfer Switch Load Center: 24, 30 or 42 Position Generator Receptacle or PanLoc Convenience Receptacle; GFI 15 amp Duplex Silkscreen, Hinged/Lift off Dead-Front 3 point latching/pad lockable door handle Door Wind Stop Captive Dead-Front Fasteners NEMA 3R, Aluminum Construction Dimensions 60h x 29w x 10d

12 Power Transfer Cabinet 47h X 24w X 6d Type 1 Power Transfer Cabinet Features/Options UL 891 Dead Front Switchboard Listed Suitable For Use As Service Equipment kaic Rating: Up to 65,000 amps Voltage: 240/120 Single Phase Three Wire and Ground Amperage: 100A or 200A Single Disconnect or Manual Transfer Switch Load Center: 24, 30 or 42 Position NO/NC Utility and/or Generator Voltage Monitoring Silk screened Dead front Captive dead front fasteners Locking Load Center Door Ground Bar (size/type optional) NEMA 1, Steel Construction Dimensions 47 h x 24 w x 6 d

13 Power Transfer Cabinet 60h X 29w X 6d Type1 Power Transfer Cabinet Features/Options UL 891 Dead Front Switchboard Listed Suitable For Use As Service Equipment kaic Rating: Up to 65,000 amps Voltage: 240/120 Single Phase Three Wire and Ground Amperage: 100A or 200A Automatic Transfer Switch or Manual Transfer Switch Load Center: 24, 30 or 42 Position NO/NC Utility and/or Generator Voltage Monitoring Silk screened Dead front Captive dead front fasteners Locking Load Center Door Ground Bar (size/type optional) NEMA 1, Steel Construction Dimensions 60 h x 29 w x 6 d

14 Telco Equipment Cabinet 18h X 18w X 8d Type 3R Features/Options UL Listed Door Louvers w/filter Aluminum frame re-usable electrostatic filters Single Point Door Latching Pad Lockable Door Handle AC or DC Fan Receptacles (GFI, Duplex etc.) Standard or Flame Retardant Plywood LED Lighting Door Alarm Contacts Ground Bar (size/type optional) Punch Down Block NEMA 3R, Aluminum Construction Dimensions 18 h x 18 w x 8 d Panprodcat2013 Rev. 2

15 Equipment Cabinet 39h X 20w X 20d Type 3R Features/Options UL Listed Door Louvers w/filter Aluminum frame re-usable electrostatic filters Three point door latching Pad lockable door handle AC or DC Fan Air Conditioner (Size/Type optional) Receptacles (GFI, Duplex etc.) Standard or Flame Retardant Plywood Equipment Rails Equipment Rack (Swing Down) Fold Down Shelf Document Holder Insulation LED Lighting Door Alarm Contacts Ground Bar (size/type optional) NEMA 3R, Aluminum Construction Dimensions 39 h x 20 w x 20 d *Safety Equipment not included

16 Telco Equipment Cabinet 59h X 24w X 20d Type 3R Features/Options UL Listed Door Louvers w/filter Aluminum frame re-usable electrostatic filters Three point door latching Pad Lockable Door Handle AC or DC Fan Air Conditioner Receptacles (GFI, Duplex etc.) Standard or Flame Retardant Plywood Equipment Rails Equipment Rack (Swing Down) Fold Down Shelf Insulation Pedestal / Wire Way LED Lighting Door Alarm Contacts Ground Bar (size/type optional) Punch Down Block Door Wind Stop NEMA 3R, Aluminum Construction Dimensions 59 h x 24 w x 20 d

17 AXT - Environmentally Controlled Cabinet Mechanical/Electrical UL Listed Enclosure Dimensions 78 h x 24 w x 24 d Three Point Latching/Pad-lockable Handle Pedestal Wire Way Lifting Eyes NEMA 3R, Aluminum Construction Features/Options Single or Double Doors Door Alarm Contacts Insulation Ground Bar (size/type optional) Receptacles (GFI, Duplex etc.) LED Lighting Equipment Rails A/C and/or Heating Unit AC or DC Fan Aluminum frame re-usable electrostatic filters Fold Down Shelf Standard or Flame Retardant Plywood Battery Trays Door Wind Stop(s)

18 19 or 23 Rack Mount Power Distribution Features/Options UL Listed Load Center 8 position kaic Rating: Up to 10,000 amps Manual Transfer Switch Ground Bar (size/type optional) Silk screened Dead front Captive dead front fasteners Mounting Flanges Receptacles (GFI, Duplex etc.) GFI Breaker NEMA 1, Aluminum Construction Dimensions 7.5 h x 17 w x 3.25 d (without mounting flanges)

19 PanLoc alternate power connection PanLoc was developed to eliminate compatibility issues between alternate Power Source and Load Distribution. Eliminates Multiple Generator Plugs and Adapters Industry Standard, color coded Single Pole Connectors Touch Safe Design Industry Standard Mounting (Left/Right) Decreased Down Time 200A, 3-Phase Capabilities kaic Rating: Up to 10,000 amps Hinged, Lift Off, Lockable, Removable Door Dimensions 24 h x 9 w x 9 d Ease of use UL Listed Patent Pending * Contact a Pantrol Inc. Sales Representative for configuration verification and *Shown mounted on a 40h x 20w x 10d AC Cabinet

20 PanLoc

21 PanLoc Lite was developed to eliminate compatibility issues between alternate Power Source and Load Distribution, in a more compact cost effective solution. Eliminates Multiple Generator Plugs and Adapters Industry Standard, color coded Single Pole Connectors Touch Safe Design Industry Standard Mounting (Left/Right) Decreased Down Time 200A, 3-Phase Capabilities kaic Rating: Up to 10,000 amps Removable access cover Dimensions 10.5 h x 9 w x 9.25 d Ease of use UL Listed Patent Pending * Contact a Pantrol Inc. Sales Representative for configuration verification and pricing PanLoc Lite Phone: (509) , Fax : (509) ,

22 Dual Source Voltage Monitoring Alarm MODEL: VM Pantrols Dual Source Voltage Monitoring Alarm module detects the presence of voltage on the line side of the main disconnect. The VM series integrates over current protection breakers and voltage sensing relays in a NEMA 3R cost effective product. VM Features: UL 508A Listed Voltage; 240V, 20 amps Utility kaic Rating 65k Generator kaic Rating 10k 4 ea. UL Listed Taps for #4 4/0 conductors 2 ea. Din Rail mounted Relay Bases with 2 ea. Normally Open (NO/NC), Electromechanical Interface relays with Surge Protection 1 ea. Grounding Lug Pad Lockable Enclosure with Single Point Latch Steel Construction, NEMA 3R Electrostatic Powder Coat Finish, ANSI Gray External Upper and Lower Enclosure Mounting Flanges 4 ea. Concentric Knock Outs on bottom of enclosure Enclosure Dimensions; 10.25H x 8.5W x 6.5D inches Weight approximately 13 lbs. Contact a Pantrol Inc. Sales Representative for configuration verification and

23 200A MANUAL TRANSFER SWITCH MODEL: K0P-000 Pantrols solution series cabinets integrate service disconnect switch, transfer switch, distribution blocks, auxiliary power inlet and other required components to provide a single source solution in a cost effective product. 200A MANUAL TRANSFER SWITCH FEATURES: Suitable for Use as Service Equipment N-G Bonding kit included Voltage: 240/120 Single Phase Three Wire and Ground Current: 200 amp AIC Rating: 65,000 amps Auxiliary power inlet: Color Coded Camlock Connectors Pin 1-Neutral (White), Pin 2-Ground (Green) Pin 3-Line 2 (Black), Pin 4-Line 1 (Red) Service Disconnect: 1-200A, 65 kaic, SQD QGL22200LU Generator Disconnect: 1-200A, 10 kaic, SQD QBL22100LU Power Distribution Blocks Non-Isolated Ground Bar 3 point door latch, Lockable L-Handle Lift Off, Silkscreen Dead-Front Captive Dead-Front Fasteners Cabinet Dimensions; 28H x 20W x 10D inches Aluminum construction, NEMA 3R Electrostatic Powder Coat Finish Weight approximately 75 lbs Contact a Pantrol Inc. Sales Representative for configuration

24 Short lead times Why Pantrol? UL listed products ISO 9001 : 2008 Registered Quality Management System Dedicated customer service In house Application/Design Engineering From Prototype to high volume manufacturing Serving industry since 1974 Products proudly made in the USA 3108 E. Ferry Ave, Spokane, WA Phone Fax or

120 VAC 18x16x8 Inch Weatherproof Enclosure with Mounting Plate, Cooling Fans and Solid State Fan Controllers Model: NB FS

120 VAC 18x16x8 Inch Weatherproof Enclosure with Mounting Plate, Cooling Fans and Solid State Fan Controllers Model: NB FS 120 VAC 18x16x8 Inch Weatherproof Enclosure with Mounting Plate, Cooling Fans and Solid State Fan Controllers Model: NB181608-10FS Applications and Features Features: Molded Fiberglass Reinforced Polyester

More information

I-Line Panelboards. Innovative design, smart bus technology, and simple installation

I-Line Panelboards. Innovative design, smart bus technology, and simple installation I-Line Panelboards Innovative design, smart bus technology, and simple installation TM Smart: designed for efficient installation Simple: Efficient Installation Process I-Line Breakers Main Lugs: Fixed-mounted

More information

3a. IEM Indoor Metal Clad Medium Voltage Switchgear 25KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

3a. IEM Indoor Metal Clad Medium Voltage Switchgear 25KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std. 3a. IEM Indoor Metal Clad Medium Voltage Switchgear 25KV 16346-1 3a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std. Relays) Part 1 General 1.1 CONDITIONS AND REQUIREMENTS: A. Refer to

More information

TYPE 4/12 PREMIER SERIES

TYPE 4/12 PREMIER SERIES Type 4 / 12 Enclosures TYPE 4/12 PREMIER SERIES ENCLO- Contemporary Contemporary Design Design Seamless Seamless Foam-In-Place Foam-In-Place Gasketing Gasketing Utility Utility Brackets Brackets for for

More information

AThink future. Switch to green. Mini Panel Board. Cost-effective, space-saving board up to 400A.

AThink future. Switch to green. Mini Panel Board. Cost-effective, space-saving board up to 400A. www.moeller.co.uk Mini Panel Board Cost-effective, space-saving board up to 400A Product Catalogue and Selection Guide Mini Panel Board Miniature Circuit Breakers Moulded Case Circuit Breakers XBoard Consumer

More information

Compact Series Wallmount Enclosures

Compact Series Wallmount Enclosures Compact Series Page 1 of 5 Overview ARIA s Compact Series are small wallmount enclosures that features patch and splice capabilities. The enclosures also support 12 fiber MPO to LC connector plug and play

More information

Remote Site Products

Remote Site Products Battery Enclosures 32 Pole Mount Our Battery Enclosures include the following features: Manufactured to NEMA 1, 3, 3R and 12 standards, providing outdoor protection against wind, blown dust, rain, sleet,

More information

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

Rhino Buffer Module PSM24-BFM600S. Operating Instructions Rhino Buffer Module PSM24-BFM600S Operating Instructions RHINO BUFFER MODULE PSM24-BFM600S Description The PSM24-BFM600S Buffer Module will hold the output voltage of a 24 VDC power supply after brownouts

More information

Kohler Generac (even new low voltage board).

Kohler Generac (even new low voltage board). Small footprint, typically a quarter of the size of 100 & 200 Amp contactors Magnetic toggle is virtually silent in operation, no heat, humming or buzzing and never electrically held in either position

More information

PRECISION LED HIGH MAST LIGHTING

PRECISION LED HIGH MAST LIGHTING THE PRECISION LED HIGH MAST LIGHTING SPEC WITH CONFIDENCE 1 TOLL-FREE: 888-410-5337 FAX: 614-868-5344 2017 SpecGradeLED INTRODUCING THE SpecGrade LED s rugged Navigator is engineered to seamlessly integrate

More information

NEW PRODUCT BULLETIN. Single Outlet Receptacle EMG-30-SD/US/15A. Features: Description:

NEW PRODUCT BULLETIN. Single Outlet Receptacle EMG-30-SD/US/15A. Features: Description: NEW PRODUCT BULLETIN Single Outlet Receptacle EMG-30-SD/US/15A January 2004 Features: DIN-Rail Mounted Fully Enclosed UL Listed: E238705 Compact Design This DIN-Rail mounted single outlet package was specifically

More information

PANELITE ENCLOSURE LIGHTS OVERVIEW

PANELITE ENCLOSURE LIGHTS OVERVIEW SPEC-00581 H763.422.2211 763.422.2600 ELECTRICAL LIGHTING PACKAGES ELECTRICAL LIGHTING PACKAGES PANELITE ENCLOSURE LIGHTS OVERVIEW FEATURES Slim profile allows light to be tucked up out of the way for

More information

Company, Simplex Onsite, providing nationwide load bank rentals.

Company, Simplex Onsite, providing nationwide load bank rentals. Trident 2500 1500KW - 2500KW Overview Integrated design, load module, trailer, reels, cam-lock style connections, digital control Very high capacity, 1500-2500kw Dual voltage: 208-240/416-480vAC Digital

More information

Power Control Systems

Power Control Systems Power Control Systems Power Control Systems for Virtually Any Control Strategy Power Control Systems for: Emergency generator control Emergency generator control with load demand sensing Emergency generator

More information

Specialized Lighting Solutions, Inc. SLS DALI CONTROLLERC

Specialized Lighting Solutions, Inc. SLS DALI CONTROLLERC DCP-A Panel Network DALI Control Panel for DALI Ballast, DALI Relays and DALI Dimmers 24 20 6 The DCP-A electronic network control panel with Clipsal DCDALCIP250-2 serial interfaces supports applications

More information

DTK-WH8PLUS. Premium Whole House Surge Protection General Product Specifications

DTK-WH8PLUS. Premium Whole House Surge Protection General Product Specifications DTK-WH8PLUS Premium Whole House Surge Protection DITEK s WH8PLUS Whole House surge protection kit is perfect for residential builders and contractors who desire to provide an additional, valuable service

More information

Redundancy unit CP-A RU

Redundancy unit CP-A RU 2CDC 271 010 F0t06 Features Decoupling of CP power supply units with 2 inputs, each up to 20 A per input / channel Output up to 40 A True redundancy by 100 % decoupling of two parallel connected power

More information

CTO CSLS CHARM Cabinets

CTO CSLS CHARM Cabinets DeltaV SIS Process Safety System Product Data Sheet November 2017 CTO CSLS CHARM Cabinets Rear View CTO CSLS CHARM Cabinet. Delivers Electronic Marshalling enabled by CHARMs technology Reduce system footprint

More information

RittalXpress TS IT Enclosure Assemble-to-Order Program

RittalXpress TS IT Enclosure Assemble-to-Order Program RittalXpress TS IT Enclosure Assemble-to-Order Program DESIGN YOUR DATA CENTER BY THE NUMBERS. Count down to success: 4, 3, 2, 1... Complete four easy steps, your order can be shipped in three days and

More information

ALL PRODUCTS UNINTERRUPTIBLE POWER SYSTEMS

ALL PRODUCTS UNINTERRUPTIBLE POWER SYSTEMS ALL PRODUCTS UNINTERRUPTIBLE POWER SYSTEMS NEXT GENERATION TECHNOLOGY Toshiba International Corporation provides a full range of Uninterruptible Power Systems (UPS) for datacenter/, commercial/ retail,

More information

Panel Enclosures. Wall-Mount Enclosures Type 12 Premier Series Double-Door with Quarter-Turn Latches Data Sheet

Panel Enclosures. Wall-Mount Enclosures Type 12 Premier Series Double-Door with Quarter-Turn Latches Data Sheet Panel Enclosures Wall-Mount Enclosures Type 12 Premier Series Double-Door with Quarter-Turn Latches Data Sheet Construction Enclosure and door are fabricated from code gauge steel (see page 153) All continuous

More information

User s Guide. Includes Mounting, Installation, and Product Registration nd Avenue NE Arlington, WA USA (+1)

User s Guide. Includes Mounting, Installation, and Product Registration nd Avenue NE Arlington, WA USA (+1) User s Guide Includes Mounting, Installation, and Product Registration 500 19009 62nd Avenue NE Arlington, WA USA (+1) 360-435-6030 European Sales Office Barcelona, España (+34) 600-843-845 www.outbackpower.com

More information

Rackmount Shelves, Wallmount Shelves, Keyboard/Mouse Trays

Rackmount Shelves, Wallmount Shelves, Keyboard/Mouse Trays Rackmount Shelves Wallmount Shelves Keyboard/Mouse Trays Product Data Sheet Rackmount Shelves, Wallmount Shelves, Keyboard/Mouse Trays Overview Black Box offers a variety of 1U, 2U, and 3U high shelves

More information

Single-Phase Encapsulated

Single-Phase Encapsulated Single-Phase Encapsulated 7 50 VA to 25 kva Applications n For general loads, indoors or out, including lighting, industrial and commercial applications n Units may be banked for 3-Phase operations n For

More information

Quick Start. This document describes how to install the Juniper Networks PTX5000 Packet Transport

Quick Start. This document describes how to install the Juniper Networks PTX5000 Packet Transport PTX5000 Packet Transport Router Quick Start September 2017 Part Number: 530-066788 Revision 01 This document describes how to install the Juniper Networks PTX5000 Packet Transport Router. Contents Quick

More information

Shelves, Keyboard Trays and Gland Plates Folding Shelves

Shelves, Keyboard Trays and Gland Plates Folding Shelves 763.422.2600 SPEC-00035 Q763.422.2211 ACCESSORIES SHELVES, KEYBOARD TRAYS AND GLAND PLATES FOLDING SHELVES Shelves, Keyboard Trays and Gland Plates Folding Shelves STAINLESS STEEL FOLDING SHELF Size AxB

More information

PLT. Breaker-based transfer switch open, closed or soft transition amps. Specification sheet

PLT. Breaker-based transfer switch open, closed or soft transition amps. Specification sheet Specification sheet PLT Breaker-based transfer switch open, closed or soft transition 800 3000 amps Description PLT breaker-based transfer switches are designed for operation and switching of electrical

More information

Isobar 6-Outlet Surge Protector, 6 ft. Cord with Right-Angle Plug, 3300 Joules, Diagnostic LEDs, Metal Housing

Isobar 6-Outlet Surge Protector, 6 ft. Cord with Right-Angle Plug, 3300 Joules, Diagnostic LEDs, Metal Housing Isobar 6-Outlet Surge Protector, 6 ft. Cord with Right-Angle Plug, 3300 Joules, Diagnostic LEDs, Metal Housing MODEL NUMBER: ISOBAR6 Highlights 6 NEMA 5-15R outlets in exclusive isolated filter banks Network-grade

More information

SECTION PANELBOARDS

SECTION PANELBOARDS SECTION 16450 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes requirements for panelboards providing fault interrupting capability and overcurrent protective devices. 1.02 REFERENCE STANDARDS A.

More information

in widespread use with Simplex sister Company, Simplex Onsite, providing nationwide load bank rentals.

in widespread use with Simplex sister Company, Simplex Onsite, providing nationwide load bank rentals. 600KW - 1250KW Overview Integrated design, load module, trailer, reels, cam-lock style connections, digital control High capacity, 600-1250kw Dual voltage: 208-240/416-480vAC Digital load control, 5 kw

More information

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS SECTION 262816 - ENCLOSED SWITCHES AND CIRCUIT BREAKERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

EMC1600 Series Media Converter and Ethernet Extender Chassis

EMC1600 Series Media Converter and Ethernet Extender Chassis EMC1600 Series Media Converter and Ethernet Extender Chassis User s Manual Preface This manual describes how to install and use the 16-Bay Media Converter and Ethernet Extender Chassis. This chassis is

More information

Transceiver Hub with Integral Camera Power

Transceiver Hub with Integral Camera Power Passive UTP Transceiver Hub with Integral Installation Guide Models Include: HubWay8CD HubWay16CD - UL Listed eight (8) Channel Passive UTP - UL Listed sixteen (16) Channel Passive UTP Transceiver Hub

More information

Mobile Rack Backplane for 2.5in SATA/SAS Drive

Mobile Rack Backplane for 2.5in SATA/SAS Drive Mobile Rack Backplane for 2.5in SATA/SAS Drive Product ID: SATSASBP125 Now it s easy to increase the storage capabilities of your server or PC while protecting data integrity. This one-bay mobile rack

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS PAC525P2 PAC526P2 PAC526P4 PAC526P6 PAC527P4 PAC527P6 In-Wall Box Power Kits Spanish Product Description German Product Description Portuguese Product Description Italian Product

More information

Passive UTP Transceiver Hub with Integral Isolated Camera Power Installation Guide

Passive UTP Transceiver Hub with Integral Isolated Camera Power Installation Guide Passive UTP Transceiver Hub with Integral Isolated Installation Guide Models Include: HubWay8Di HubWay16Di - UL Listed eight (8) Channel Passive UTP - UL Listed sixteen (16) Channel Passive UTP Transceiver

More information

Doepke MAIN SWITCH OPTIONS. The insulated consumer unit range consists of four enclosure sizes to enable any combination from 1 to 16 usable ways.

Doepke MAIN SWITCH OPTIONS. The insulated consumer unit range consists of four enclosure sizes to enable any combination from 1 to 16 usable ways. Doepke The insulated consumer unit range consists of four enclosure sizes to enable any combination from 1 to 16 usable ways. Designed to meet BSEN60439-3 these easy to install consumer units accept the

More information

DOCKING STATION SPECIFICATIONS

DOCKING STATION SPECIFICATIONS ONE PERSON STATION Power Outlets Data Jack Plate Mouse Brackets Front Covers Cable Holes Cable Holes Overview: The Docking Station distributes power, data, and laptop storage to each user. It also offers

More information

Zenith Series MDU & RDU. Critical Power Distribution Units

Zenith Series MDU & RDU. Critical Power Distribution Units Zenith Series MDU & RDU Critical Power Distribution Units Touching all Areas of the Energy Industry GE s diverse portfolio of products and services is helping customers solve problems every day. We touch

More information

Allworx 24x Service and Troubleshooting Guide

Allworx 24x Service and Troubleshooting Guide Allworx 24x Service and Troubleshooting Guide -PAGE INTENTIALLY LEFT BLANK- Table of Contents 1 Safety Instructions...1 1.1 Electrical...1 1.2 Electrostatic Discharge...1 2 Chassis Views...2 3 Exterior

More information

SSW06. Soft Starters. Applications. Standard Features. Pumps Fans Blowers Compressors Crushers Saws Grinders Mixers.

SSW06. Soft Starters. Applications. Standard Features. Pumps Fans Blowers Compressors Crushers Saws Grinders Mixers. General Information CFW10 CFW100 CFW08 CFW500 CFW700 CFW701 CFW11 EDP11 CFW11M SSW05 SSW07 GPH2 TPH2 The is WEG s third generation Soft Starter line. The keypad, with dual display, has red LED digits which

More information

iconverter 2-Module Power Chassis

iconverter 2-Module Power Chassis iconverter 2-Module Power Chassis User Manual 38 Tesla, Irvine, CA 92618 USA Phone: (949) 250-6510; Fax: (949) 250-6514 Page 1 Warning The operating description in this Instruction Manual is for use by

More information

Haworth Power Technical Sheets January 2018

Haworth Power Technical Sheets January 2018 Haworth Power Technical Sheets January 2018 Includes Accessories This page intentionally left blank. Table of Contents Desk Top Port Power Tap Cord Power Tap Conduit Enchanced Power Module Flip Top Unit

More information

Content. - Equipment/Racks - Open System Racks - ODF/ MMF/ DDF Frames - Outdoor Equipment Cabinets - Customized Racking

Content. - Equipment/Racks - Open System Racks - ODF/ MMF/ DDF Frames - Outdoor Equipment Cabinets - Customized Racking Content 1.1 Racking System 1.1.0 Overview 3 4 1.2 19 Equipment Racks 5 1.3 19 Cable Management Rack 6 1.4 Open System Rack 7 1.5 Outdoor Cabinet 1.5.1 TSM Outdoor Cabinet 1.5.2 DLC Outdoor Cabinet 8 9

More information

Liebert TVSS: The First Line of Defense - Product Overview. Jim Tiesi

Liebert TVSS: The First Line of Defense - Product Overview. Jim Tiesi Liebert TVSS: The First Line of Defense - Product Overview Jim Tiesi INTERCEPTOR SURGE SUPPRESSION Overall Design True modular design Low impedance copper conduction plates Best in class performance Real-time

More information

Passive UTP Transceiver Hub with Integral Camera Power Installation Guide

Passive UTP Transceiver Hub with Integral Camera Power Installation Guide Passive UTP Transceiver Hub with Integral Installation Guide Models Include: HubWay8D HubWay16D - Eight (8) Channels - Sixteen (16) Channels HubWay82D HubWay162D - HubWay8 w/eight (8) HubWayAv - HubWay16

More information

SP SP-T-9

SP SP-T-9 INSTALLATION INSTRUCTIONS Revision B1 Rapid City, SD, USA, 04/2010 MODELS 201-100-SP 201-200-SP 201-200-SP-T-9 II_201-SP_B1 2880 North Plaza Drive, Rapid City, South Dakota 57702 (800) 843-8848 (605) 348-5580

More information

ViewPoint Monitoring Console System

ViewPoint Monitoring Console System ViewPoint Monitoring Console System with sit/stand capability flexible, scalable system provides operators with the ability to sit or stand for optimum operator effectiveness features: Bays adjust from

More information

TRC-190 User s Manual

TRC-190 User s Manual User s Manual Edition 3.2, May 2017 www.moxa.com/product 2017 Moxa Inc. All rights reserved. User s Manual The software described in this manual is furnished under a license agreement and may be used only

More information

UL 489 DIN Rail Miniature Circuit Breakers

UL 489 DIN Rail Miniature Circuit Breakers UL 489 DIN Rail Miniature Circuit Breakers Product Overview................................................ 2 Product Selection................................................ 4 Accessories.....................................................

More information

Solar Combiner Enclosure

Solar Combiner Enclosure Installation Instructions Solar Combiner Enclosure Catalog Numbers 1000-SB006, 1000-SB012 Topic Page Description 1 Important Safety Instructions 3 Nameplate Data 4 Planning for Installation 4 Install the

More information

Installation Notes TII Model 341 Protector

Installation Notes TII Model 341 Protector Installation Notes TII Model 341 Protector (ATT-IS PEC 32918) for MERLIN Communications System In Range Out of Building (IROB) Station Installation By Trained Technician Only WARNING: Failure to follow

More information

RuggedMC RMC40 RUGGEDCOM ISO 9001 REGISTERED. Features and Benefits. 4-Port Ethernet Media and Speed Converter

RuggedMC RMC40 RUGGEDCOM ISO 9001 REGISTERED. Features and Benefits. 4-Port Ethernet Media and Speed Converter Features and Benefits 4-Ethernet Ports with Optional Dual Fiber Optics Three configurations to choose from: z2 10/100TX ports + 1 100FX port (SC/ST) z2 10/100TX ports + 2 100FX port (MTRJ/LC) z4 10/100TX

More information

Owner s Manual. Isolate. Restore. Inspire! Power Conditioners Audio / Video Power Isolation Units Rack Mount / Consumer Series

Owner s Manual. Isolate. Restore. Inspire! Power Conditioners Audio / Video Power Isolation Units Rack Mount / Consumer Series Owner s Manual 19 Pro Series Rack Mount (RK) Faceplate Isolate. 17 Consumer Series (C) Faceplate Available in Black (B) and Silver (S) Colours Restore. Power Conditioners Audio / Video Power Isolation

More information

FUSERBLOC UL Fusible disconnect switches UL and CSA 30 to 800 A

FUSERBLOC UL Fusible disconnect switches UL and CSA 30 to 800 A Fuse protection The solution for > Motor load break. > Protection of industrial cabinet. > Electrical distribution. ul_004_a Strong points fuser-ul_006_a Function FUSERBLOC UL fusible disconnect switches

More information

NetSure 802 SERIES DC POWER SYSTEM

NetSure 802 SERIES DC POWER SYSTEM NetSure 802 SERIES DC POWER SYSTEM Ordering Guide DRAFT NETSURE 802 SERIES DC POWER SYSTEM ORDERING GUIDE DRAFT Description The modular NetSure 802 power system is made up of an assortment of bays that

More information

Medium-Voltage Circuit Breaker-Type Automatic Transfer Switches and Bypass/Isolation Switches

Medium-Voltage Circuit Breaker-Type Automatic Transfer Switches and Bypass/Isolation Switches Medium-Voltage Circuit Breaker-Type Automatic Transfer Switches and Bypass/Isolation Switches RTS SERIES RTS Series Medium-Voltage Circuit Breaker-Type Automatic Transfer Circuit breaker medium-voltage

More information

Temperature. Power requirements. Weight. Dimensions

Temperature. Power requirements. Weight. Dimensions Installing the Tracer Summit BMTX Building Control Unit Ordering numbers: BMTX001AAB000, BMTX001AAB010, BMTX001AAB001, BMTX001AAB011, BMTX001BAB000, BMTX001BAB010, BMTX001BAB001, BMTX001BAB011, BMTX001DAB000

More information

3M ID 3000 System. ID 3128 block. Disconnection module. ID 3100 block Wire guide housing

3M ID 3000 System. ID 3128 block. Disconnection module. ID 3100 block Wire guide housing 3M ID 3000 System ID 3128 block Disconnection module ID 3100 block Wire guide housing 71 Disconnection element 72 The ID 3000 connection system is the latest generation of insulation displacement connector

More information

3RA13, 3RA14 Contactor Assemblies

3RA13, 3RA14 Contactor Assemblies RA1, RA Contactor Assemblies RA1 complete units,... kw Overview The RA1 reversing contactor assemblies can be ordered as follows: Sizes S00 to S Fully wired and tested, with mechanical and electrical interlock

More information

ArmorConnect Power and Control Media

ArmorConnect Power and Control Media Selection Guide ArmorConnect Power and Control Media Bulletins 280, 888, 889, 898 2 Bulletin 280, 888, 889, 898 Power Media Product Overview Media Description Features Trunk Cable Cordset - Cable with

More information

SECTION SWITCHGEAR

SECTION SWITCHGEAR SECTION 26 23 13 SWITCHGEAR PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections,

More information

Series 575. Vertical Flow Modular Softwall Cleanroom. Series 575 Vertical Flow Modular Softwall Cleanroom

Series 575. Vertical Flow Modular Softwall Cleanroom. Series 575 Vertical Flow Modular Softwall Cleanroom Series 575 Vertical Flow Modular Softwall Cleanroom S O L U T I O N S The Series 575 softwall cleanroom is a cost-effective method of providing quality particulate control in a softwalled enclosure. The

More information

Eaton 9PX PowerPass Distribution Modules and Transformers 9PXTFMR5, 9PXPPDM2, 9PXTFMR11, and 9PXPPDM1 User's Guide

Eaton 9PX PowerPass Distribution Modules and Transformers 9PXTFMR5, 9PXPPDM2, 9PXTFMR11, and 9PXPPDM1 User's Guide Eaton 9PX PowerPass Distribution Modules and Transformers 9PXTFMR5, 9PXPPDM2, 9PXTFMR11, and 9PXPPDM1 User's Guide For use with 9PX 5000/6000/8000/11000 VA UPS Models FCC Part 15 Class A EMC Statements

More information

STORAGE & ACCESSORIES

STORAGE & ACCESSORIES STORAGE & ACCESSORIES TABLE OF CONTENTS STORAGE Structural & Hanging Pedestals... 4 Mobile Pedestals... 6 Low Storage... 8 Storage Towers... 10 Lateral Files... 12 Overhead Storage... 14 ACCESSORIES Single

More information

Hardened Media Converter

Hardened Media Converter Quick Start Guide This quick start guide describes how to install and use the hardened media converter. This is the media converter of choice for harsh environments constrained by space. Physical Description

More information

OmniSmart 120V 330VA 225W UL Medical Grade Line-Interactive UPS, Tower, DB9 Serial

OmniSmart 120V 330VA 225W UL Medical Grade Line-Interactive UPS, Tower, DB9 Serial OmniSmart 120V 330VA 225W UL 60601-1 Medical Grade Line-Interactive UPS, Tower, DB9 Serial MODEL NUMBER: OMNISMART350HG Highlights 330VA line interactive tower UPS Maintains sine-wave 120V nominal output

More information

SSW06. Soft Starters.

SSW06. Soft Starters. The is WEG s third generation Soft Starter line. The keypad, with dual display, has red LED digits which provide visibility and make programming easier. Integral bypass contacts eliminate heat dissipation

More information

Lift Truck Parts Professionals

Lift Truck Parts Professionals SB Connector 50 Amp Series connectors Housing w/springs Anderson Brad Anderson & contacts Wire AWG Part # Harrison # Part # Original # Gray 50 amp #6 69 900 000 7-70-P 000 7-70 #0/# 69G 90 000 7-7-P 000

More information

INSTRUCTION MANUAL DIGI-LOCK. Keyless Entry System. Installation. Programming. Troubleshooting. BASE Industries

INSTRUCTION MANUAL DIGI-LOCK. Keyless Entry System. Installation. Programming. Troubleshooting. BASE Industries INSTRUCTION MANUAL DIGI-LOCK Keyless Entry System Installation Programming Troubleshooting BASE Industries 45 Pomona Rd. Corona, CA. 9880 Revision F TABLE OF CONTENTS OWNER REGISTRATION CARD INTRODUCTION

More information

PowerLogic High Density Metering System 1-Meter Enclosure

PowerLogic High Density Metering System 1-Meter Enclosure PowerLogic High Density Metering System 1-Meter Enclosure Installation Guide 63230-508-211A1 Safety information PowerLogic High Density Metering System 1-Meter Enclosure Important information Read these

More information

AC5160 SiPass integrated controller kit

AC5160 SiPass integrated controller kit AC5160 SiPass integrated controller kit SiPass integrated Wall housing with pre-assembled basic SiPass integrated components Equipped with one ACC (AC5100), two dual reader interfaces (ADD5100) and one

More information

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600 REDUNDANCY MODULE TSP-REM360 AND TSP-REM600 Operating Instructions Seite 1 Dimensions drawings: TSP-REM360 Weight: 0.882lb Gewicht: 0.40kg Seite 2 Dimensions drawings: TSP-REM600 Bottom view Top view Side

More information

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual This package is designed to simplify the connections to our Secured Series Hub Plus Controller. This will translate into

More information

CS7 Industrial Control Relays

CS7 Industrial Control Relays CS7 Industrial Control Relays Reliable, general purpose relays for heavy duty applications The base four pole CS7 relay can be expanded up to twelve poles with the addition of front and side mount auxiliaries

More information

Chassis Overview. About the Cisco NCS 4016 Chassis. This chapter provides an overview of the Cisco NCS 4016 chassis and components.

Chassis Overview. About the Cisco NCS 4016 Chassis. This chapter provides an overview of the Cisco NCS 4016 chassis and components. This chapter provides an overview of the Cisco NCS 4016 chassis and components. About the Cisco NCS 4016 Chassis, page 1 Chassis Components, page 6 Chassis Cable Management, page 11 Safety Guidelines,

More information

3RM1 Hybrid Starters 6SIRIUS. contents. Industrial Controls Product Catalog 2017

3RM1 Hybrid Starters 6SIRIUS. contents. Industrial Controls Product Catalog 2017 3RM1 Hybrid Starters Industrial Controls Product Catalog 2017 Section contents 3RM1 Compact - Hybrid Starters Overview /2 General Data /3 Selection and ordering data /4 Accessories /5 - /9 Technical Data

More information

SERVER RACKS & ACCESSORIES SERVER RACKS & ACCESSORIES

SERVER RACKS & ACCESSORIES SERVER RACKS & ACCESSORIES DESIGNED & MDE IN USTRLI SERVER RCKS & CCESSORIES SERVER RCKS & CCESSORIES Consulting 3D Prototyping Custom Server Racks 20 Series Racks IP Outdoor Enclosures SCEC Endorsed Cabinets Secure Data Cage Hot

More information

Intelligent-Remote Monitoring (3) Power Circuit Environmental Port (4) Power Outlet Level (5) PDU De-Rated Power Watts (W) PDU Nominal.

Intelligent-Remote Monitoring (3) Power Circuit Environmental Port (4) Power Outlet Level (5) PDU De-Rated Power Watts (W) PDU Nominal. Enclosure Power Distribution Units (PDUs) (continued) PDU Selection: Basic, with ocal Monitoring and Intelligent Highly secure access with admin, control and view-only accounts Intuitive Ethernet-based

More information

Overall Dimensions AE2M-1000 MADJ MW(X)CBLKMP 1000-MPBM. For Reference Only

Overall Dimensions AE2M-1000 MADJ MW(X)CBLKMP 1000-MPBM. For Reference Only AE2M-1000 MADJ MW(X)CBLKMP (Fixture Series) Overall Dimensions Optic Assembly 1000-MPBM (Remote Ballast Series) Weight Remote Ballast 65 lbs (29.48 kgs) For Reference Only The Arena Eclipse blackout luminaire

More information

TECHNICAL DATASHEET Heavy Duty - Absolute Encoder AR 62/63

TECHNICAL DATASHEET Heavy Duty - Absolute Encoder AR 62/63 AR 6 Single and Multi turn: Resolution up to 8 Bit Wearless electronic multi turn: contact -and battery less, self-energetic 300 N axial and radial load 00 g shock resistance/ 0 g vibration resistance

More information

Micro-Ohmmeters. Digital 10A. Models 6240 & Measure low resistance with high accuracy. Selectable test current and resistance ranges

Micro-Ohmmeters. Digital 10A. Models 6240 & Measure low resistance with high accuracy. Selectable test current and resistance ranges Digital 10A Micro-Ohmmeters Models 6240 & 6250 Measure low resistance with high accuracy Selectable test current and resistance ranges 0.1µΩ resolution Simple one button press-to-start operation Software

More information

10-Port Industrial USB 3.0 Hub - ESD and Surge Protection. StarTech ID: ST1030USBM

10-Port Industrial USB 3.0 Hub - ESD and Surge Protection. StarTech ID: ST1030USBM 10-Port Industrial USB 3.0 Hub - ESD and Surge Protection StarTech ID: ST1030USBM This 10-port USB 3.0 hub gives you the scalability you need in harsh industrial environments. It s designed to meet the

More information

ADDENDUM INSTALLATION INSTRUCTIONS. Powered In-Wall Storage Boxes. PAC525FxP2 / PAC526FxP2 / PAC526FxP4 / PAC526FxP6

ADDENDUM INSTALLATION INSTRUCTIONS. Powered In-Wall Storage Boxes. PAC525FxP2 / PAC526FxP2 / PAC526FxP4 / PAC526FxP6 INSTALLATION INSTRUCTIONS ADDENDUM PAC525FxP2 PAC526FxP2 PAC526FxP4 PAC526FxP6 Powered In-Wall Storage Boxes Spanish Product Description German Product Description Portuguese Product Description Italian

More information

UL 489 Cable-In / Cable-Out Branch Circuit Breaker

UL 489 Cable-In / Cable-Out Branch Circuit Breaker Product Overview UL 9 Cable-In / Cable-Out Branch Circuit Breaker PRODUCT OVERVIEW Optimum and Efficient Protection Features Complete range of UL 9 listed DIN rail mounted miniature circuit breakers up

More information

Security Solutions. Installation Manual Revision - April, 2004

Security Solutions. Installation Manual Revision - April, 2004 Security Solutions S321-DIN Controller Installation Manual 24-10046-18 Revision - April, 2004 1757 Tapo Canyon Road, Simi Valley, CA 93063 Tel (805) 522-5555 Fax (805) 582-7888 www.johnsoncontrols.com

More information

ISOLATION RELAY RACK ISOLATION KIT 19 RACK MOUNT RELAY RACK ISOLATION KIT, SLOTTED UNEQUAL FLANGE RACK ISOLATION KIT 23 RACK MOUNT

ISOLATION RELAY RACK ISOLATION KIT 19 RACK MOUNT RELAY RACK ISOLATION KIT, SLOTTED UNEQUAL FLANGE RACK ISOLATION KIT 23 RACK MOUNT ISOLATION Info: 9070 = Isolation RELAY RACK ISOLATION KIT 19 RACK MOUNT 9070-1019 19" Rack Mount 23 RACK MOUNT 9070-1023 23" Rack Mount RELAY RACK ISOLATION (KIT) RELAY RACK ISOLATION KIT, SLOTTED 19 RACK

More information

SECTION SURGE PROTECTION DEVICES. A. Section includes Surge Protection Devices for low-voltage power, control, and communication equipment.

SECTION SURGE PROTECTION DEVICES. A. Section includes Surge Protection Devices for low-voltage power, control, and communication equipment. SECTION 26 43 00 SURGE PROTECTION DEVICES PART 1 - GENERAL 1.1 SUMMARY A. Section includes Surge Protection Devices for low-voltage power, control, and communication equipment. 1.2 DEFINITIONS A. ATS:

More information

GFCI (RCD) RECEPTACLES AND PLUGS 2 Pole 3 Wire Grounding

GFCI (RCD) RECEPTACLES AND PLUGS 2 Pole 3 Wire Grounding GFCI (RCD) RECEPTACLES AND PLUGS 2 Pole 3 Wire Grounding AU1-10R AU1-10P FR1-R EU1-P Cat. No. Drawing Configuration Australian GFCI (RCD) angle plug. trip. 10 ampere 230 volt, 50 Hz. 20 watt maximum. Test

More information

CONSOLE CONNECTOR KIT 9501 INSTALLATION INSTRUCTIONS

CONSOLE CONNECTOR KIT 9501 INSTALLATION INSTRUCTIONS CONSOLE CONNECTOR KIT 9501 INSTALLATION INSTRUCTIONS FOR USE WITH: HAMMOND Organ Models L-100, M-100 Series, M-l, M-2, M-3 LESLIE Speaker Models 760, 770, 825 KIT CONTENT Console Connector Assembly 043075

More information

BMCS CCX Cabinet. BMCS_CCX Cabinet is secured via a switchable 6A circuit breaker. Note the right selectivity ratio of your feeding.

BMCS CCX Cabinet. BMCS_CCX Cabinet is secured via a switchable 6A circuit breaker. Note the right selectivity ratio of your feeding. Version: 2011-01-13 BMCS CCX Cabinet Description & Function: The BMCS_CCX Cabinet is a ready to install wall housing for one or more BMCS systems (see figures 1 to 3). The BMCS_CCX Cabinet is designed

More information

Consumer units IP66 >> M135 DOMINO IP66 Series [enclosure] 672.

Consumer units IP66 >> M135 DOMINO IP66 Series [enclosure] 672. 1 Empty enclosures DOMINO IP66 Series Consumer units IP66 >> M135 INDUSTRY 2 DIN 2 3 4 CONSUMER UNIT Modularity No. Modules Dimension Power IP66 M135 2 MOD. 135x76x102mm 6W 2002 1/24 DOMINO IP66 Series

More information

Prisma II Platform. Optoelectronics

Prisma II Platform. Optoelectronics Optoelectronics Prisma II Platform Description In optical transmission systems, the network platform forms the foundation of the product family. The Prisma II platform provides network operators with the

More information

Free-Stand Universal-Cutout Disconnects Type 12 Modular Free-Stand Disconnects and Accessories

Free-Stand Universal-Cutout Disconnects Type 12 Modular Free-Stand Disconnects and Accessories 763.422.2600 Spec-00252 L763.422.2211 Free-Stand Universal-Cutout s Type 12 Modular Free-Stand s and accessories Free-Stand Universal-Cutout s Type 12 Modular Free-Stand s and Accessories Modular Enclosure,

More information

The PCI Series. Precise power control for complex SCR applications. Phase Angle Fired SCR Power Controls AMPS VAC

The PCI Series. Precise power control for complex SCR applications. Phase Angle Fired SCR Power Controls AMPS VAC The PCI Series Phase Angle Fired SCR Power Controls 25-1200 AMPS 120-600 VAC Precise power control for complex SCR applications. ROBICON 1996 Distributed Worldwide by www.mcgoff-bethune.com Applications

More information

Installation Manual. Integrated System. V-Series Power Family Doc. No , Issue 8 Published 11-Dec-09

Installation Manual. Integrated System. V-Series Power Family Doc. No , Issue 8 Published 11-Dec-09 Installation Manual Integrated System V-Series Power Family Doc. No. 2056560, Issue 8 Published 11-Dec-09 Information in this document is subject to change without notice and does not represent a commitment

More information

PSR-SCP- 24DC/URM4/4X1/2X2/B PSR-SPP- 24DC/URM4/4X1/2X2/B

PSR-SCP- 24DC/URM4/4X1/2X2/B PSR-SPP- 24DC/URM4/4X1/2X2/B Safety Relay as a Contact Extension Block INTERFACE Data Sheet PHOENIX CONTACT - 05/2006 Description The PSR-...- 24DC/URM4/4X1/2X2/B safety relay can be used as a contact extension block in safety circuits

More information

Removing Components from the MX960 Chassis Before Installing It Without a Lift

Removing Components from the MX960 Chassis Before Installing It Without a Lift Removing Components from the MX6 Chassis Before Installing It Without a Lift If you cannot use a mechanical lift to install the router (the preferred method), you can install it manually. Before installing

More information

1. Carefully unpack the um260 s shipping carton and check the contents for damage.

1. Carefully unpack the um260 s shipping carton and check the contents for damage. um260 Installation Manual um260 Installation Chapter 4 um260 MICRO MONITOR INSTALLATION This section of the um260 Micro Monitor Installation Manual describes the requirements and procedures for installing

More information

InForm Superstructures

InForm Superstructures Advantages InForm racks are fitted between the vertical profiles and thus ensure a generous amount of open working table surface. Devices are installed directly in the 3HU and 6HU racks, additional devices

More information