3M Indoor Protected Building Entrance Terminal 4588V-QCS Series
|
|
- Millicent Cross
- 6 years ago
- Views:
Transcription
1 3M Indoor Protected Building Entrance Terminal 4588V-QCS Series with 3M Quick Connect System 2811 Dry Flame Retardant Block Instructions Underwriters Laboratories (UL 348X) Listed April A
2 1.0 General The 3M Indoor Protected Building Entrance Terminal (IBET) 4588V-QCS Series provides electrical protection and a termination point for outside plant cable (feeder) and indoor house wiring (distribution). The 4588V-QCS IBET is Underwriters Laboratories (UL 348X) Listed Series IBET Names, Pair Capacity and Module 4588QCS-HCCA/25SD 4588QCS-HCCA/50SD 4588QCS-HCCA/100SD 25-pair HiCat Indoor Building Entrance Terminal with 710 SD 50-pair HiCat Indoor Building Entrance Terminal with 710 SD 100-pair HiCat Indoor Building Entrance Terminal with 710 SD 1.2 IBET Parts and Components a) Connectorized tails with 3M flame-retardant modules. 3M MS² Super Mini Splicing Module 4000-D/CO, 3M MS² Fire Retardant Pluggable Module 4005-DPM/FR or 3M 710 Splicing System SD modules. b) Splice chamber, for the feeder cable, with cable strain relief. (Note diagram) c) Insulated #6 ground strap for the feeder cable. d) External bottom-mounted three point ground bar and top-mounted single point ground bar. (Note diagram) e) Numbered standard 5-pin protector receptacle field. (Note diagram) f) Binding post log and instruction label. g) The 3M Single Pair Test Probe and Dish. h) Fully lockable protective cover. i) Three (3) screws (2 small and 1 large) to wall mount the IBET Terminal. (Note diagram) 1.3 IBET Dimensions and Wiring Schematic 26 AWG Fuse Wire 4588 QCS-50 Protector Model Height Width Depth 4588QCS QCS Protector Specifications Use ONLY UL Recognized or Listed five-pin protectors in the 4588V-QCS terminal. 1.5 Special Tools Needed to Install 3M MS 2 modules or 3M 710 connectors (Not required if 3M Scotchlok Connectors are used) Module From C.O. 4588V-QCS Wiring Schematic 2810 Block A
3 2.0 Terminal Location and Mounting 2.1 Locate the terminal according to standard operating procedures. Consider the following points: a) Locate the terminal inside the building as close as possible to cable entrance. b) Locate the terminal on a firm mounting surface where it will be accessible to the technicians at all times; where it can be reached without a ladder; and where it will not project in a hazardous manner. c) Observe caution when exposing the terminal to chemicals in liquid or vapor form as they may damage the plastic components. CAUTION Avoid locations near flammable materials, ignitable gases, dust, moisture, temperature extremes, moving machinery, electric light and power circuits, and electrical equipment. 2.2 Open the splicing chamber by loosening the bolt securing the splicing chamber door. Open the splicing chamber door. (See fig. 7.02) 2.3 Pull the preterminated short stub, insulated ground wire, and accessories out of the splicing chamber. 2.4 Mount the terminal in designated position with the three mounting screws provided. 2.5 Remove the jumper wire retaining ring from poly bag and install in faceplate. 3.0 Feeder Cable Preparation and Strain Relief 3.1 Feeder cable diameters for the 3M Indoor Building Entrance Terminal (IBET) 4588V-QCS Series Feeder Cable PET Pair Count Minimum Maximum Diameter Diameter 25.42" 1.08" 50.63" 1.45" If the cable diameter is smaller than the minimum, use 3M 130C tape to build up to the minimum. 3.2 Run the feeder cable 24" past the IBET terminal cable entry port. 3.3 Slide the 3M Pull N Shrink Tube (PST) on the end of the cable with the pull-tab away from the IBET terminal and temporarily keep it out of the way pair 100 pair 3.4 With the groove toward the IBET terminal and long end toward the cable, snap the cable gland halves around the cable. Slide the gland into the entry port of the IBET terminal. 3.5 Measure 2" of sheath past the gland inside the IBET terminal. Pull the gland and cable out of the IBET terminal. 2" A 3
4 3.6 Remove the sheath, leaving at least 21" of free conductor length. Identify and secure the cable groups ends. Bond the cable shield according to your company s practice pair 3.7 Insert the gland s groove into the cable port. Slide the 3M Pull N Shrink Tube (PST) over the gland and slowly unwind the core. The PST fits over either the small diameter of the pair gland or butts up against the 3M Indoor Building Entrance Terminal (IBET) 4588V-QCS for the 100 pair gland. 3.8 Complete the PST core removal over the gland. 3.9 The blank plate MUST be used in the empty cable port for UL Listing Attach the cable to the wall according to your company s practice. 4.0 Terminal Grounding 4.1 Fasten a #6 AWG wire to the ground bar which is located on the front of the unit. Connect other end of ground wire to local ground per company standards. Note: Failure to properly bond and ground the terminal per N.E.C. or local equivalent codes may render protection arrestors useless. 4.2 Module splicing. Splice per your company practice. 4.3 Splice the feeder cable groups to the corresponding connectorized stubs according to your company s practice M Scotchlok Connector or individual connector splicing 4.5 Splice the feeder cable groups to the corresponding connectorized stubs in the IBET terminal according to your company s practice. 4.6 When all splicing is completed, bundle the groups and secure them with tie wraps into the splice chamber on the left side. 4.7 Close the IBET terminal splice chamber cover and secure with the lockplate bolt. (See 7.02) 5.0 Distribution (House) Wire Termination 5.1 Remove the block from frame. Rotate the block 180. backward and remount in same frame position with 1-pair jumper caps facing out. Push the block firmly into place on the frame. Cable pairs should now enter the back side of the block from below. Repeat until all feeder and distribution blocks have been terminated and mounted to frame A
5 6.0 Running Jumpers 3M Quick Connect System 2810 Block 6.1 Open the feeder pair jumper cap by pushing up on the latch and rotating up. Insert jumper wire ends A (tip) left and B (ring) right into wire openings in the cap, making sure they are inserted all the way to the back of the cap. 6.2 While holding the jumper wires in place, close the cap and press to snap the latch firmly into place. 6.3 Route the jumper wires to the distribution pair through wire loops on the block ends and through vertical and horizontal wireways. Cut jumper wires to appropriate length, leaving at least 5 cm (2 in.) of slack. 6.4 Terminate the jumper wires to the distribution pair by repeating the procedure described in steps 3.1 and Terminate additional jumper wires by repeating the above procedure. 6.6 To remove jumper wires, open the cap and pull the wires straight out from block. 6.7 Route the wire below the connected cap. 7.0 Installing the Electrical Protectors Note: Use ONLY UL Recognized or Listed protectors in the IBET. 7.1 The 3M Indoor Building Entrance Terminal (IBET) 4588V-QCS uses a standard five pin protector receptacle field. The long pins of the protector connect Tip and Ring from the feeder cable though the protector to the short pins to the distribution/house wire. 7.2 Insert protectors into the protector receptacle field according to your company s practice A 5
6 7.3 To disconnect the distribution wire, pull the protector out to the detents on the long pins to hold it in place. This continues to protect from the feeder cable side. 8.0 Protective Cover 8.1 With the cover closed, the exposed hasp allows for locking when security is required M Single Pair Test Probe Testing using 3M Single Pair Test Probe Plug the test probe into the cap of the pair being tested, with the black lead to the left and the red lead to the right M Priority Caps 10.1 Priority Caps are used to designate special purpose circuits and prevent entry of the 3M Single Pair Test Probe A
7 10.2 To install Priority Caps, place over the jumper cap of the pair to be marked and push it into place. Latching is indicated by an audible snap Multiple 3M Indoor Building Entrance Terminal (IBET) 4588V-QCS Installation Note: Use this application when the required cable pair capacity exceeds the capacity of a single IBET Terminal The design of the splice chamber and the grooved cable glands make it possible to stack the IBET terminal vertically, up to three of the same cable pair count and within the diameter limits in the chart in Mounting the IBET terminal a) Mount the IBET terminal bodies using the cable glands to position them. b) Assemble the feeder cable strain relief according to Section 3.0 and prepare the feeder cable so that 21" of free conductor length will be in the last IBET terminal. 21" 1" minimum 2.75" minimum 11.3 Place cable glands around the free conductors and position into the IBET terminal Separate the feeder cable pair assigned to each IBET terminal; splice and bond the IBET terminal according to section A 7
8 A
9 A 9
10 3M, MS 2 and Scotchlok are trademarks of 3M Company. Important Notice All statements, technical information, and recommendations related to 3M s products are based on information believed to be reliable, but the accuracy or completeness is not guaranteed. Before using this product, you must evaluate it and determine if it is suitable for your intended application. You assume all risks and liability associated with such use. Any statements related to the product which are not contained in 3M s current publications, or any contrary statements contained on your purchase order shall have no force or effect unless expressly agreed upon, in writing, by an authorized officer of 3M. Warranty; Limited Remedy; Limited Liability. This product will be free from defects in material and manufacture for a period of one (1) year from the time of purchase. 3M MAKES NO OTHER WARRANTIES INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. If this product is defective within the warranty period stated above, your exclusive remedy shall be, at 3M s option, to replace or repair the 3M product or refund the purchase price of the 3M product. Except where prohibited by law, 3M will not be liable for any indirect, special, incidental or consequential loss or damage arising from this 3M product, regardless of the legal theory asserted. 3 Communication Markets Division 6801 River Place Blvd. Austin, TX Please Recycle. Printed in USA. 3M All Rights Reserved A
3M Indoor Building Entrance Terminal (IBET) 4790V and 4790VL Series
3M Indoor Building Entrance Terminal (IBET) 4790V and 4790VL Series with 3M Quick Connect System (QCS) 2811 Dry Flame-Retardant Block and RJ-11 Test Ports Instructions Underwriters Laboratories (UL 348X)
More informationIndoor Protected Entrance Terminal 4588 Series
Indoor Protected Entrance Terminal 4588 Series Instructions Underwriters Laboratories (UL) Listed September 2003 78-8135-1209-8-A 1.0 General The 3M Indoor Protected Entrance Terminal (PET) 4588 Series
More information3M Indoor Protected Building Entrance Terminal 4788V-QCS Series
The Network of Networks. 3M Indoor Protected Building Entrance Terminal 4788V-QCS Series with 3M Quick Connect System (QCS) 2811 Dry Flame Retardant Block for Field-Terminated Building Cables Instructions
More information3M Indoor Protected Building Entrance Terminal (IBET) 4688V Series
3M Indoor Protected Building Entrance Terminal (IBET) 4688V Series Instructions Underwriters Laboratories (UL 348X) Listed February 2017 78-0013-6127-4-B 2 February 2017 78-0013-6127-4-B 1.0 General The
More information4188, 4288, 4288-S and 4688 Protected Entrance Terminals
4188, 4288, 4288-S and 4688 Protected Entrance Terminals Instructions Underwriters Laboratories (UL) Listed January 1997 34-7041-3837-8 Revision A Contents: 1.0 General... 1 2.0 Accessories... 2 3.0 Protector
More information4888 and 4988 Outdoor Protected Entrance Terminals
4888 and 4988 Outdoor Protected Entrance Terminals Underwriters Laboratories (UL) Listed Instructions January 1997 34-7031-7272-5 Revision C Contents: 1.0 General... 1 2.0 Accessories... 2 3.0 Protector
More information3M Add-On Terminals 4220P (100, 200, 300 & 400 pairs)
3M Add-On Terminals 4220P (100, 200, 300 & 400 pairs) Instructions August 2011 3 78-8130-2330-1-C 1.0 General 1.1 The 3M Add-On Terminals 4220P-100, 4220P-200, 4220P-300 and 4220P-400 are designed to expand
More information3M DSLAM Mounting Bracket Kit J0746
3M DSLAM Mounting Bracket Kit J0746 Instructions July 2009 3 Contents 1.0 3M DSLAM Mounting Bracket J0746 - Installation...3 2.0 DSLAM Installation, Nokia...5 3.0 Accessory Kit, Cable Addition Shroud J0747
More information3M Cross-Connect Cabinet Riser Installation Guide
3M Cross-Connect Cabinet Riser Installation Guide Installing riser in stake, hand hole and pad-mount applications Instructions October 2016 78-0015-3063-9-B 2 October 2016 78-0015-3063-9-B Contents 1.
More information3M Quick Connect System (QCS) 2814
Communication Markets Division 3M Quick Connect System (QCS) 2814 Designed for your broadband network The 3M Quick Connect System 2814 is a terminal/cross-connect system featuring integrated protection
More information3M Quick Connect System (QCS) 2811
Communication Markets Division 3M Quick Connect System (QCS) 2811 Designed for your broadband network The 3M Quick Connect System (QCS) 2811 is an insulation displacement connector (IDC) termination system
More informationA Full Range for Different Applications The STG2000 modules offer three different types of IDC circuits. The Network of Networks
The Network of Networks 3M High Density Cross-Connect Modules STG2000 Series The 3M High Density Cross-Connect Modules STG2000 Series are IDC copper cross-connects that can be used in a wide variety of
More information3M I/O Connector Mounting Options and Hardware
M I/O Connector Mounting Options and Hardware Hardware Guide Date Modified: July 20, 2009 Part Number Type Mounting Hardware Applications - Table 1 Mini D Ribbon (MDR) Conn. s D Sub Conn. s D Ribbon Conn.
More information3M Serial Advanced Technology Attachment (SATA) Connector Signal Plug, Boardmount, Surface Mount Right Angle and PTH Vertical
7-position supports motherboard signal requirements EMLB contacts for hot swap Blind mate polarization for easy cable attach Through-hole and surface mount options PCB retention clip aids manufacturing
More information3M Pak 100 Wiremount Plug Series
Pak 100 Wiremount Plug Shrouded to protect against physical and chemical pin damage Open or closed end covers available Optional ejector latches Accepts flat cable or discrete wire Military (with 3518
More informationModel 1100B CHG Terminator. Operating Instructions
Model 1100B CHG Terminator Operating Instructions 1 Contents: 1.0 Safety Information... 3 2.0 General Introduction... 3 3.0 Operation... 4 2.8 2.1 2.7 V 2.2 2.9 2.2 2.10 2.11 2.11 2.3 2.4 2.5 2.5 2.6 2
More information3 Angled Connector Housing (MC) Installation
Angled Connector Housing (MC) Installation Instructions July 1999 4-7047-2554-7 MC Frame Figure 1 Angled Connector Housing (MC) General This document describes the installation of the stubbed MC Angled
More information3M I/O Connector Mounting Options and Hardware
M I/O Connector Mounting Options and Hardware Hardware Guide Date Modified: January 14, 2008 Part Number Type Mounting Hardware Applications - Table 1 Mini D Ribbon (MDR) Conn. s D Sub Conn. s D Ribbon
More information3M Constant Monitors WSMONITOR1, WSMONITOR 2, WSMONITOR3
3M Constant Monitors WSMONITOR1, WSMONITOR 2, WSMONITOR3 User s Guide WSMONITOR1 WSMONITOR2 WSMONITOR3 Table of Contents Section Page SAFETY INFORMATION...3 Introduction...5 Installation...6 Operation...9
More informationA significantly increased capacity compared to other techniques is achieved with the compact SID-C module.
3 Quante SID System With the SID-C product family, 3M is setting the standard for high-density IDC termination combined with improved handling. The main applications are in telecommunications and data
More information3M Mini-Clamp Socket 2 mm Boardmount, Straight Solder Tails 372 Series
2 mm Boardmount, Straight Solder Tails 72 Series Compact design saves board space High number of mating cycles Mating latch features provide a reliable interconnection in demanding applications Enables
More informationMounting Bracket for 8 in. Charles Industries Pedestal for use with 3M Fiber Dome Terminal Closure FDT 08
Mounting Bracket for 8 in. Charles Industries Pedestal for use with 3M Fiber Dome Terminal Closure FDT 08 Instructions October 2006 78-8135-6184-8-A 1.0 Introduction This kit mounts a 3M Fiber Dome Terminal
More information3M Fiber Dome Closure FDC 08S-A. 3M Fiber Dome Closure FDC 08S-B. Constructed of highly chemicalresistant
The new, compact 3M Fiber Dome Closure FDC 08S is a hermetically sealed fiber dome closure for aerial, buried above-grade, and buried below-grade applications. This closure is designed to meet the needs
More information3M Compact Coarse Wave Division Multiplexer (CCWDM) Module Installation
3M Compact Coarse Wave Division Multiplexer (CCWDM) Module Installation Instructions June 2010 3 Contents 1.0 Introduction...3 2.0 Kit Contents...3 3.0 Preparation and Installation of One and Two 3M Compact
More information3M Passive Optical Splitter Shelves and Modules
Communication Markets Division 3M Passive Optical Splitter Shelves and Modules 3M offers a robust portfolio of passive optical fiber splitter products made to enable easy configuration, design, ordering,
More information3M Cross-Connect Cabinets for Midspan Applications
Communication Markets Division 3M Cross-Connect Cabinets for Midspan Applications 3M Cross-Connect Cabinets for midspan applications are low-count cabinets available in configurations that can accommodate
More information3M Boardmount Socket 2 mm x 2 mm Straight Surface Mount, Straight and Right Angle Plated Through-Hole 1502 Series
M Boardmount Socket High Temperature Insulator Reflow Solder ompatible Low height helps minimize PB stack height End Stackable Thru-hole versions are side stackable SMT parts are available in tape and
More information3 710 Splicing System 1
3 710 Splicing System 1 3M 710 Splicing System Modules are available for straight, half-tap and bridge splicing Several splice module configurations allow multiple options when designing a communications
More information3M 4-Wall, Tripolarized Header.050".100" Latch/Ejector, PTH & SMT Straight, PTH Right Angle 810 Series
Tripolarized for robust alignment when mating to 820 series socket 50 mil 100 mil halves the connector length vs. traditional 100 mil x 100 mil products Latching Ejector for rugged high performance applications
More information3M Fiber Distribution Units 8400 Series
Communication Markets Division 3M Fiber Distribution Units 400 Series Flexible options to meet growing needs in limited spaces 3M offers a full line of patch panel designs to simplify your cable management
More information3M SLiC Fiber Splicing Workstation with Cleaver Arm
3M SLiC Fiber Splicing Workstation with Cleaver Arm Terminal Closure 530 Closures 533, 547 and 733 Instructions September 2016 78-8135-7148-2-D 2 September 2016 78-8135-7148-2-D 1.0 General 1.1 The 3M
More information3M Duplex Polishing Machine 6851-E with Universal Dual Holder Instructions
3M Duplex Polishing Machine 6851-E with Universal Dual Holder Instructions Safety Information Read, understand and follow all safety information contained in these user instructions prior to use of the
More information3M Cold Shrink QS-III Inline Splice Kits 15 kv 5415A, 5416A, 5417A, 5417A-WG, 5418A and 5418A-WG
3M Cold Shrink QS-III Inline Splice Kits 15 kv Data Sheet July 2013 Jacketed Concentric Neutral (JCN) 5415A, 5416A, 5417A, 5418A Concentric Neutral (JCN) 5417A-WG and 5418A-WG! CAUTION Working around energized
More information3M Cold Shrink QS-III Inline Splice Kits 25/28 kv 5456A, 5456A-WG, 5457A, 5457A-WG, 5458A and 5458A-WG
3M Cold Shrink QS-III Inline Splice Kits 25/28 kv 5456A, 5456A-WG, 5457A, 5457A-WG, 5458A and 5458A-WG Data Sheet July 2013 Jacketed Concentric Neutral (JCN) 5456A, 5457A and 5458A Concentric Neutral (JCN)
More information3M SLiC Fiber Aerial Terminal Closure 530 Internal for Direct Spliced Drop Terminations. 3M External Cable Assembly Module (ECAM) 12mm Drop Entry Kit
3M SLiC Fiber Aerial Terminal Closure 530 Internal Drop Terminations for Direct Spliced Drops The 3M SLiC Fiber Aerial Terminal Closure 530 with Internal Drop Termination is an aerial, strand-mount, free-breathing
More informationConductive Pressure Sensitive Cover Tape 2666
3 Conductive Pressure Sensitive Cover Tape 2666 Technical Data January, 2007 Product Description 3M Conductive Pressure Sensitive Cover Tape 2666 is a transparent, conductive polyester film tape with a
More information3M Fibrlok II Angle Fiber Splice 2529-AS 3M Fibrlok 250 µm Angle Fiber Splice 2540-AS
3M Fibrlok II Angle Fiber Splice 2529-AS 3M Fibrlok 250 µm Angle Fiber Splice 2540-AS Instructions January 2009 78-8140-1580-2-C Contents 1.0 Summary...3 2.0 Splicing Set-up...4 3.0 Fiber Preparation...4
More information3M Textool BGA Test & Burn-In Sockets 1.00 mm, Types 0, I, II and III Open Top
Textool BGA Test & Burn-In Sockets 1.00 mm, Types 0, I, II and III Open Top Double-beam normally-closed contact delivers balanced, opposing forces to solder ball with minimal shear stress Contact tips
More information3M Connectors for CFast Cards The Next Generation of Removable CompactFlash Storage
3M Connectors for CFast Cards The Next Generation of Removable CompactFlash Storage 3M 2011. All Rights Reserved. Introduction Purpose To explain the features and benefits of the 3M Connectors for removable
More information3M Cold Shrink QS-III Inline Splice Kits 35 kv 5535A and 5536A
3M Cold Shrink QS-III Inline Splice Kits 35 kv Data Sheet July 2014! CAUTION Working around energized high-voltage systems may cause serious injury or death. Installation should be performed by personnel
More informationC5C Cross-Connect System
C5C Cross-Connect System I N S T A L L A T I O N I N S T R U C T I O N High-Density Connection Blocks 1.0 General Product Information The C5C cross-connect system is comprised of a high-density connection
More information3M Fiber Dome Terminal Closures FDTC 08M and FDTC 08S External Drop Termination
3M Fiber Dome Terminal Closures FDTC 08M and FDTC 08S External Drop Termination The compact 3M Fiber Dome Terminal Closures FDTC 08M and FDTC 08S are hermetically sealed fiber dome terminal closures for
More informationFor more information, visit: 3M Cold Shrink QS-III Splice a one-piece joint with wide range and geometric stress control
for Medium Voltage Grid Automation Visibility inreal Time An effective solution for monitoring your underground distribution system 3M is a global technology company, manufacturing over 50,000 products
More informationStart Here. All-in-One Printer. Print Copy Scan
Start Here All-in-One Printer Print Copy Scan Note: A USB 2.0 cable is required to connect your Kodak All-in-One printer to your Windows or Macintosh OS computer. Available in the Kodak online store or
More information3M AEROSPACE & COMMERCIAL TRANSPORTATION DIVISION St. Paul, MN USA or or Made in USA
3M AEROSPACE & COMMERCIAL TRANSPORTATION DIVISION St. Paul, MN 55144-1000 USA www.3m.com/aerospace or 1-800-364-3577 or 1-800-235-2376 Made in USA with US and Globally Sourced Materials 3M 2015. All rights
More informationModel 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1
Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.keithley.com Model 2460-KIT Screw Terminal Connector Kit Description The Model 2460-KIT Screw Terminal Connector Kit
More informationLA600WH WIRED / WIRELESS DOOR CHIME
LA600WH WIRED / WIRELESS DOOR CHIME To register this product, visit: www.nutone.com THIS PACKAGE INCLUDES: Wired / Wireless Door Chime with MP3 upload capability Decorative White Chime Cover USB Cable
More information3M Sensored Cable Accessories for Underground Medium Voltage Distribution System
3M Sensored Cable Accessories for Underground Medium Voltage Distribution System 3M Electronics & Energy Business 1 Introduction The focus on enhancing reliability and efficiency of the power grid has
More informationInstallation Notes TII Model 341 Protector
Installation Notes TII Model 341 Protector (ATT-IS PEC 32918) for MERLIN Communications System In Range Out of Building (IROB) Station Installation By Trained Technician Only WARNING: Failure to follow
More informationInstalling the NEMA 4X Hatch
Installing the NEMA 4X Hatch ET 350 Monitor (Models ET 350R and ET 350L3) and ET 3170 Terminal Intended Use When properly installed using the materials provided, and according to these instructions, the
More informationPICO PROTECTOR PG-25 & PK-25 Series
PICO PROTECTOR PG-25 & PK-25 Series Installation Instructions LISTED 95P5 SIGNAL CIRCUIT PROTECTOR Introduction The Siemon Company s Pico Protector Kits protect voice and data equipment from sneak current
More information3M Workstation Monitor Checker CTE701A User s Guide
3M Workstation Monitor Checker CTE701A User s Guide Table of Contents Section Page Intended Use...3 1.0 Quick Tour of your 3M Workstation Monitor Checker CTE701A...4 2.0 Basics...5 3.0 Metal Ground...5
More information3M Power Clamp System Power/Signal Distribution I/O Connector System
3M Power Clamp System Power/Signal Distribution I/O Connector System 3M 2011. All Rights Reserved. Introduction Purpose To explain the features and benefits of the 3M Power Clamp System Objectives Highlight
More informationVolition. VF-45 Singlemode Socket and Patch Cords. 3Innovation IT'S AS EASY AS PLUGGING IN AN RJ-45.
Volition VF-45 Singlemode Socket and Patch Cords IT'S AS EASY AS PLUGGING IN AN RJ-45. The Volition VF-45 Singlemode Socket and Patch Cords from 3M are the latest duplex, fiber optic interconnect products
More informationKM-4800w. Installation Guide
KM-4800w Installation Guide TABLE OF CONTENTS page 1 Installation Requirements 2 2 Unpacking 3 2. 1 Unpacking 3 2. 2 Confirmation of Accessories 5 3 Leveling the Machine 7 4 Setup of the Roll Deck 9 5
More information3M Category 6 Copper Structured Cabling System
Communication Markets Division 3M Category 6 Copper Structured Cabling System 3M RJ45 Category 6 Jacks UTP PL 3M Copper Patch Cords 3M Copper Patch Panels 3M Faceplates & Wall Outlets 3M Copper Cable 3M
More information3M Fiber Distribution Units 8400 Series. The Network of Networks. Flexibility for. Networks. Growing
3M Fiber Distribution Units 8400 Series The Network of Networks Flexibility for Growing Networks Flexible options to meet growing needs in limited spaces 3M offers a full line of patch panel designs to
More information3M Textool Open-Top Test and Burn-In Sockets for Ball Grid Array Packages
3M Textool Open-Top Test and Burn-In Sockets for Ball Grid Array Packages 3Innovation Table of Contents Product Advantages...1 Durability...1 Reliability...2 Micro-Wiping and Solder Ball Deformation...3
More information3M Cold Shrink QS4 Integrated Splice Kits 35 kv
3M Cold Shrink QS4 Integrated Splice Kits 35 kv 1/0-350 For Jacketed Concentric Neutral (JCN), Flat Strap, Tape Shield and Longitudinally Corrugated (LC) Cables Data Sheet July 2014! CAUTION Working around
More informationChoose the Right Interconnect Solutions for FTTH Drop Cable Installations
Choose the Right Interconnect Solutions for FTTH Drop Cable Installations Business White Paper The Network of Networks Jerry D. Jackson Marketing Manager 3M Communication Markets Division Introduction
More information3M SlimLine 85ohm Cable Assembly
Product Specifications May 2017 78-5102-0240-7, Rev B Scope This document summarizes test methods, test conditions, and product performance requirements for 3M SlimLine 85ohm Cable Assembly. Reference
More informationProgressive Industries, Inc. EMS Electrical Management System
Progressive Industries, Inc. EMS Electrical Management System Complete Installation Guide and Operating Instructions for: Model EMS-LCHW50 Rated at 240V/50A Manufactured by: Progressive Industries, Inc.
More informationSystem Accessories. features and benefits. standards. An Evolant Solutions Product
features and benefits Accessories designed specifically for the UMOXS cross-connect system Sealed plant design Wire termination tool and fixture Multi- or single-pair test probes standards UMOXS Cross-Connect
More informationVolition. Multimode VF-45 Socket and Patch Cords. 3Innovation
Volition Multimode VF-45 Socket and Patch Cords It's as easy as plugging in a rj-45. The Volition VF-45 Socket and Patch Cords from 3M are the latest duplex, fiber optic interconnects for affordable, high
More informationGeneral Process Specification for Reflow Soldering of Boardmount 3M Pak Connectors, 3M CF Card Headers and 3M PCMCIA Sockets and Headers
General Process Specification for Reflow Soldering of Boardmount 3M Pak Connectors, 3M CF Card Headers and 3M PCMCIA Sockets and Headers Technical Report November 2004 78-8136-1133-8-A Table of Contents
More informationCONNECTOR AND RECEPTACLE WIRE/CABLE ASSEMBLY INSTRUCTIONS
CONNECTOR AND RECEPTACLE WIRE/CABLE ASSEMBLY INSTRUCTIONS Throughout this manual, look for this symbol. It means BE ALERT YOUR SAFETY IS INVOLVED. If you do not follow these safety instructions, personal
More information3M Fiber Dome Closure Family. Reliable. Fiber. Protection
3M Fiber Dome Closure Family Reliable Fiber Protection More flexibility for your complex fiber optic network A full line of closures and accessories designed to help protect fiber optic facilities in many
More information3M Wrist Strap and Ground Monitor 773. User s Guide
3M Wrist Strap and Ground Monitor 773 User s Guide Table of Contents Section Page Safety Information... 2 1 Description... 4 Overview... 4 Performance... 4 2 Installation... 5 Supplied Parts... 5 Wire
More informationEMS. Electrical Management System. Progressive Industries Incorporated Morrisville, North Carolina
Progressive Industries Warranty Progressive warrants its products are free from defects in materials and workmanship for a period of three years. This is in lieu of all other warranties, obligations, or
More information3M Connectors for Embedded Systems Connectors for AdvancedTCA, CompactPCI and MicroTCA Systems from 3M
3M Connectors for Embedded Systems Connectors for AdvancedTCA, CompactPCI and MicroTCA Systems from 3M 3M 2011. All Rights Reserved. Introduction Purpose To explain the features and benefits of the connectors
More informationProduct Discontinuation Notice 3M Assorted Japan Sourced Connectors
Product Discontinuation Notice 3M Assorted Japan Sourced Connectors Issue Number: 756 Date: March 26, 2010 Product Discontinuance Effective June 1, 2010, 3M will exit a few assorted low volume Japanese
More informationINSTALLATION AND USER GUIDE 2800MWB SINGLE LINE BASIC FEATURE TELEPHONE
INSTALLATION AND USER GUIDE 2800MWB SINGLE LINE BASIC FEATURE TELEPHONE TeleMatrix Copyright 2005 COMPLIANCE AND SAFETY As specified by FCC regulation, we are required to inform you of specific governmental
More informationVolition. Multimode VF-45 Socket and Patch Cords. 3Innovation
Volition Multimode VF-45 Socket and Patch Cords O b D s oc ol e um te en t It's as easy as plugging in a rj-45. The Volition VF-45 Socket and Patch Cords from 3M are the latest duplex, fiber optic interconnects
More informationSATA II HDD Canister KISS DA 435 Quick Reference Guide
SATA II HDD Canister KISS DA 435 Quick Reference Guide If it s embedded, it s Kontron 1. Table of Contents SATA II HDD Canister KISS DA 435 1. Table of Contents 1. Table of Contents... 1 2. Important Information...
More informationOutdoor PTZ. Mounting on the Ceiling Using Pendant Mount. Installation Guide. For Models: I93, I94, I95, I96, KCM /12/03
Outdoor PTZ Mounting on the Ceiling Using Pendant Mount For Models: I93, I94, I95, I96, KCM-8211 2013/12/03 Table of Contents Mounting Solutions... 3 Straight Tube Installation Procedures... 4 Step 1:
More informationTrueNet 1U and 2U Fiber Panel Installation and Cable Routing Instructions
TrueNet 1U and 2U Fiber Panel Installation and Cable Routing Instructions ADCP-92-082 Issue 2 10/2008 1U PANEL 2U PANEL 22049-A Content Page INTRODUCTION.............................................................................
More informationCrimplok ST* and SC Non-Adhesive Fiber Optic Single & Multi-mode Connectors
Crimplok ST* and SC Non-Adhesive Fiber Optic Single & Multi-mode Connectors Instructions July 2002 78-8073-7660-9-F 1 Contents 1.0 Warnings and Recommendations... 3 2.0 Tool Kit Contents... 4 3.0 Termination...
More informationSPECIAL APPLICATION MANUAL PART NUMBER: TNP121UL. Tilt N Plug Jr. Table Top Interconnect Box USER'S GUIDE
MANUAL PART NUMBER: 400-0429-001 TNP121UL Tilt N Plug Jr. Table Top Interconnect Box USER'S GUIDE INTRODUCTION Your purchase of the UL Listed TNP121UL, Tilt N Plug Jr. Interconnect Box is greatly appreciated.
More informationDynatel Advanced Modular System 965AMS ADSL2+ Service Module
3 Dynatel Advanced Modular System 965AMS ADSL2+ Service Module User s Guide Future-Proof Testing Platform May 2006 78-8135-5269-8 Contents ADSL2+ Service Module...5 Module Installation...5 Hook-Up...6
More informationDynatel.Advanced.Modular.System. 965AMS.VDSL2.Service.Module.
3 Dynatel.Advanced.Modular.System. 965AMS.VDSL2.Service.Module. User s.guide Future-Proof Testing Platform October 2007 78-8135-7673-9 Contents VDSL2 Service Module...5 Introduction...5 Module Installation...6
More informationNew Product Release Summary for 3M Authorized Sales Reps and Distributors 3M Industrial M12 Wiremount Connectors, 3N104 and 3N304 Series
3M Industrial M12 Wiremount Connectors, 3N104 and 3N304 Series Issue Number: 838 Date: December 12, 2012 Product Description The 3M Industrial M12 Wiremount Connectors are an expansion of 3M s extensive
More informationCubePro. Main PCB Replacement Guide. Prosumer 3D Printer. Original Instructions
CubePro Prosumer 3D Printer Main PCB Replacement Guide Original Instructions 1 INTRODUCTION COPYRIGHT 2014 by All rights reserved. This document is subject to change without notice. This document is copyrighted
More information3M 100G QSFP28 Direct Attach Copper Cable Assemblies, 9Q Series
Product Specifications June 2017 78-5102-0262-1, Rev A 3M 100G QSFP28 Direct Attach Copper Cable Assemblies, 9Q Series Scope This document summarizes test methods, test conditions, and product performance
More informationInstallation Guide. Retrofit Kit for USB Ready Intraoral Systems
Installation Guide Retrofit Kit for USB Ready Intraoral Systems Table of Contents Wall-Mount Retrofit Kit... 2 Introduction... 2 Connecting the Articulating and Horizontal Arm Cables... 2 Installing the
More informationWhen any of the following symbols appear, read the associated information carefully. Symbol Meaning Description
Uni-I/O Modules Installation Guide UIS-04PTN Uni-I/O is a family of Input/Output modules that are compatible with the UniStream control platform. This guide provides basic installation information for
More informationBroadband Automatic Disconnect Switch. User Manual
Reset/Test Primary/ Primary Broadband Automatic Disconnect Switch User Manual Local Power Remote Pwer Local 63V Fault Secondary Select Secondary 220V Normal 990-1929 09/2004 Introduction Introduction
More informationDemo Kit Quick Start Guide
Near Field Imaging (NFI) Projected Capacitive Touch Screen Systems Read and understand all safety information contained in this document before using this product. Introduction This is intended to help
More informationDOOR INTERCOM SYSTEM WITH 2.4 COLOUR LCD
DOOR INTERCOM SYSTEM WITH 2.4 COLOUR LCD Model Number: HE414114 INSTRUCTION MANUAL After Sales Support 02 Door Intercom System with 2.4 Colour LCD Warranty Details The product is guaranteed to be free
More information3M Data Center Solutions. Innovation. is the. Solution
3M Data Center Solutions Innovation is the Solution Biometric Physical Security Multi-factor biometric access control reader for data center physical security needs. Air Filtration Filters help provide
More informationVisit us at
TM PRO3000 Toner and Probe Users Guide 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com PN 2440799 (English) October 2005 2005 Fluke
More informationInstallation Instructions
50ES, 50EZ, 50GL, 50GS, 50GX, 50JS, 50JX, 50JZ, 50SD, 50SZ, 50VL, 50VT, 50XP, 50XZ 601A, 602A, 602B, 604A, 604B, 604D, 607C, 701A, 702A, 702B, 704A, 704B, 704D, 707C PA1P, PA2P, PA3P, PH1P, PH2P, PH3P
More informationCab Box Kit Dome Plug Cab Box Cab Box Lid
DirectCommand Installation Ag Leader Technology Note: Indented items indicate parts included in an assembly listed above Part Name/Description Part Number Quantity Direct Command Kit 4100578 1 Cable Installation
More informationEnphase S-Series Microinverter and Engage Cable Safety
SAFETY Enphase S-Series Microinverter and Engage Cable Safety Important Safety Information (S280-60-LL and S230-60-LL) This document contains important instructions to use during installation of the Enphase
More informationProliphix EPA-60 Installation Guide
Proliphix EPA-60 Installation Guide Rev 1.2 Page 2 of 5 Installation CAUTION THE EPA-60 SHOULD ONLY BE POWERED WITH THE PROLIPHIX POWER SUPPLY INCLUDED WITH THE EPA-60. DO NOT POWER THE EPA-60 WITH ANY
More informationZ-Truck (Vertical Moving) Z-truck Flag. Y-Truck (Horizontal Moving) FIGURE 1: VIEW OF THE Z-TRUCK. Flexshaft Assembly
Replacing the LCD Cable To remove and replace the LCD Cable you will need the following tools: #2 Phillips screwdriver (magnetic tip preferred) Socket wrench with 10mm socket Removing the Side Panel 1.
More informationWhen any of the following symbols appear, read the associated information carefully. Symbol Meaning Description
Uni-I/O Modules Installation Guide UID-0808THS Uni-I/O is a family of Input/Output modules that are compatible with the UniStream control platform. This guide provides basic installation information for
More informationSERVICE MANUAL MODEL SSW-520-F
SSW-520-F-ISSUE4.0 SERVICE MANUAL FOR MODEL SSW-520-F HANDS FREE STAINLESS STEEL TELEPHONE EQUIPPED WITH LOW POWER SPEAKER BOARD Serving the Telephone Industry Since 1930 Communication Equipment 519 West
More informationInstruction Manual. Electrical Management System (EMS) EMS-HW30C & EMS-HW50C
Instruction Manual Electrical Management System (EMS) EMS-HW30C & EMS-HW50C EMS-HW50C EMS-HW30C! CAUTION These instructions are intended to provide assistance with the installation of this product, and
More informationRack Mount Cabinet with Fiber Mgmt System, accepts up to 3 Adapter Plates. Rack Mount Cabinet with Fiber Mgmt System, accepts up to 6 Adapter Plates
SEPTEMBER 2009 RACK MOUNT CABINETS Be sure to read and completely understand this procedure before applying product. Be sure to select the proper Optical Cable Corporation product before application. Product
More informationUSER MANUAL. TS Series (Model 52X) Terminal Strip Surge Protectors. SALES OFFICE (301) TECHNICAL SUPPORT (301)
USER MANUAL TS Series (Model 52X) Terminal Strip Surge Protectors Part# 07M52X-A Doc# 074170U Revised 10/21/96 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 http://www.patton.com 1.0 WARRANTY
More information