General Specifications
|
|
- Melvyn Dixon
- 6 years ago
- Views:
Transcription
1 General Specifications -A Yokogawa Y-Flow YFFC Orifice Flow Computer Overview Yokogawa s low power orifice flow computer offers flexible I/O points and superior data collection with a wide range of connectivity options. By combining Yokogawa s EJX910A multivariable transmitter (DP and SP) and Y-Flow YRTU, the accuracy and stability specifications make the Y-flow a superior product with market. Whether you are measuring gas flow for custody transfer or need wellhead control and monitoring, Yokogawa offers both the performance and stability required in the most rigorous environment. API Chapter 21 compliancy AGA 3 & 5 capability AGA 8 (Detailed & Gross Methods I & II) & NX-19 Single and Bi-Directional (total vol. + avg. vol.) measurement Multiple run capability Solar panel with battery back-up or AC powered with battery back-up Wide array of wireless connectivity options (Cellular, wireless radio and satellite) Pole mount, wall mount or direct mount options Wide variety of enclosure size options Yokogawa EJX910A Multivariable Transmitter Accuracy Specifications Specifications for the EJX910A are condensed for the purpose of this document. Please see GS01C25R01-01EN for more detailed information. The EJX910A uses the established DPharp pressure sensor technology that allows for simultaneous measurement of differential pressure and static pressure (absolute or gauge) from one sensor. Out of all the Yokogawa pressure transmitters, the EJX910A has the best accuracy for combined DP and SP measurement, which makes it an excellent choice for flow calculations with a YRTU. Reference Accuracy Measurement Span/Range M H DP inh20 SP psia Span 2 to to 3300 Range -400 to to 3300 Span -10 to to 3300 Range to to 3300 (Includes terminal-based linearity, hysteresis, and repeatability) DP Up to ±0.04% of span standard SP ±0.1% of span (Absolute) Long Term Stability (All normal operating conditions, including overpressure effects) DP ±0.1% of URL per 10 years Turndown DP 200:1 SP 25:1 Yokogawa Corporation of America 2 Dart Road, Newnan, Georgia U.S.A
2 2 YFFC Technical Specification Input Power Supply Input Power: VDC One (1) power supply/rechargeable battery input with screw terminals Integrated solar panel charger supporting up to 20W solar panel Power Monitoring and Battery Backup Supply voltage monitoring through A/D with low supply voltage alarm 3.6 VDC lithium ion battery backup for database, history, audit trial, time/date and RAM 20W on board battery charger, 90W maximum 32AH solar panel battery (optional) Performance Processor: ARM Dual Core Mhz SRAM Memory: 32MB SPI Flash Memory: 32MB A/D: 16-bit with optional HART filtering Display Options 4 line alphanumeric display with push button keypad Enclosure ARCA-JIC Series NEMA 4X Non-Metallic, UL 50 Compliant. Designed to NEMA 3R after milling and external mechanisms are added. Stainless steel lockable latch & continuous hinge with FIP door gasket. culus Approval: E (Type 1) Enclosure Vibration Test Sweep frequency endurance test on x,y, and z axis from 10 Hz-2000Hz; with Endurance Dwell test for 15 mins at 0.5G. Based on IEC Operating Temperature -40C to 70C (-40F to 160F) Communications Options Standard: Two (2) Serial RS-232/RS-485 One (1) Ethernet port, (1) USB Host Port, (1) USB Device Port Wireless Communication: Cellular (CDMA/GSM), Radio (spread spectrum licensed & unlicensed frequency), Satellite (LEO &GEO) Protocols: MODBUS TCP/IP, MODBUS Serial, ERC Hex ASCII (native) Input and Output (I/O) Analog Inputs: Four (4) universal analog inputs, 0-5VDC or 4-20mA (Requires 250 ohm resistor) RTD Inputs: One (1) temperature probe Digital Input/Output: Two (2) form A/C pulse input, Two (2) form C relays, Two (2) DI, Two (2) DO Optional I/O Extender Board Two (2) Serial RS-232/RS-485 Four (4) universal analog inputs One (1) analog output One (1) RTD temperature probe Two (2) form A/C pulse input Three (3) DI, Three (3) DO Opto 22 G4 Voltage Signal Conditioner Approval UL and cul Class I Div II Group A,B,C,D Software Field Manager Warranty 4 years limited warranty
3 3 Model Codes Model Connection 1 R/YFFC EFM- Flow Computer Multi-variable Transmitter; Range Omni (Stubby) -A % 3300G 0.1% -A8 +/ % 3300G 0.1% -A % 3300G 0.1% -B1 +/ % 3300G 0.1% Temp 1 Bulkhead Ext Serial Port 1 ESP 2 ESP Com Gear A3 15 Freewave FGR Freewave MM2 Mounting A3 Freewave MM2-P-T A9 MDS EL805 Pole Mount B1 Iridium 9602 Direct Mount B2 Multi-Tech V A3 Wall Mount B3 Multi-Tech A LCD Display B5 MDS Kit B6 Freewave FGR Kit 4 Line Connection 2 A3 Keypad & 4 Line Laptop Connection Omni (Stubby) Bulkhead RS232 (MS) E3 Processor A3 USB Ethernet -A3 Full (Both) E3UES Relays; Form C Com Gear Freewave FGR (1) Form C (2) Form C - Freewave MM2 Battery (with tray, wire & fuse) Note -A3 Freewave MM2-P-T -A9 MDS EL805 7AH -B1 Iridium B2 Multi-Tech V -B3 Multi-Tech A -B5 MDS Kit -B6 Freewave FGR Kit A3 17AH 1 A4 32AH 2 Sample MS Code: R/YFFC-A7--A3--A4/ Notes: Note 1: 17 Ah Battery requires minimum 12x10x6 enclosure Note 2: 32 Ah Battery requires minimum 14x12x7 enclosure Note 3: Increase the enclosure size by 2
4 4 A6 Solar Not Attached Pressure 1 50G A8 3 Modules - 8 VDC 3 A9 3 Modules - 2x8 ; 1x35 VDC 3 B2 3 Modules - 1x8 ; 2x35 VDC 3 B4 3 Modules - 35 VDC 3 Extender A8 200G B2 500G (4) 8 VDC B5 1500G Temp 2 B7 3000G C2 C4 150HG 300HG 6 10 Pressure 2 A Optos -A6 50G -A8 200G -B2 500G -B5 1500G -B7 3000G -C2 150HG -C4 300HG - - Red (DC Out) - Wht (DC In) -A3 Yel (AC In) -A4 Blk (AC Out) -A5 Red \ Red -A6 Red \ White Analog Out -A7 White \ White Enclosure; Dimensions in Inches Analog Output (3 chan) A4 10x10x6 SPM Signal Protection Module A5 12x10x6 A6 14x12x7 (4) 8 VDC A7 16x14x8 (4) 35 VDC A8 18x16x10 A4 8 & 35 Power Option A6 35 & 35 / Y-Flow Accessories Sample MS Code: R/YFFC-A7--A3--A4/ Notes: Note 1: 17 Ah Battery requires minimum 12x10x6 enclosure Note 2: 32 Ah Battery requires minimum 14x12x7 enclosure Note 3: Increase the enclosure size by 2 M1274XE M1274XF M1274XG M1274XH M1274XJ RS- 232 Serial PC Cable; 10 ft RS- 232 Serial PC Cable; 15 ft RS- 232 Serial PC Cable; 25 ft USB to Serial Adapter Cable USB 2.0 A-Male to B-Male 10 ft
5 5 YFFC Dimensional Drawing
6 6 E3 Processor Board Wiring
7 7
8 8 Yokogawa Corporation of America W. Airport Blvd., Sugar Land, TX yokogawa.com/us Yokogawa Canada, Inc. Bay 4, th Street SE, Calgary, AB T2C 2Z4 yokogawa.com/ca Yokogawa de Mexico, SA de CV Urbina No. 18 Parque Industrial Naucalpan Naucalpan de Juarez, Estado de México C.P yokogawa.com/mx
General Specifications
General Specifications Yokogawa Y-Flow Remote Terminal Unit (YRTU) Overview Yokogawa s low power YRTU offers flexible I/O points and superior data collection with a wide range of connectivity options.
More informationY-Flow Field Flow Computer & Remote Terminal Unit BU 04Q01A01-01E-A
E GLE RESE RCH CORPOR TION Y-Flow Field Flow Computer & Remote Terminal Unit BU 04Q01A01-01E-A Y-Flow Processor Board Yokogawa s Y-Flow processor board consists of a 32bit ARM dual core CPU with 32MB of
More informationYokogawa Y-Flow Product Family BU 04Q01A01-01E-A
Yokogawa Y-Flow Product Family BU 04Q01A01-01E-A Introduction RTU FFC With over 100 years of research and development in flow and data acquisition technology, Yokogawa s Y-Flow product line provides unparalleled
More informationYokogawa Y-Flow Product Family. Pre-Release BU 04Q01A01-01E-A
Yokogawa Y-Flow Product Family Pre-Release BU 04Q01A01-01E-A Y-Flow Processor Board Yokogawa s Y-Flow processor board consists of a 32bit ARM dual core CPU with 32MB of SRAM (database) memory and 32MB
More informationµflo 6200 Series Overview 6200 Series Products µflo 6200 Series
Data Sheet µflo 6200 Series Overview 6200 Series Products µflo 6200 Series INTRODUCTION Based on ABB Totalflow XSeries technology, the µflo 6210/6213 (microflo) is a little sibling to the XFC and XRC (extendable
More informationJT400 Multivariable Transmitter
Product Specification Sheet JT400 Multivariable Transmitter Wireless Ultra Low Power Platform with Integrated, Chart Replacement Data Logging and I/O The industry s first, ultra-low power, multivariable
More informationSCADAPack Smart RTU
SCADAPack 330 334 Smart RTU 1 Built on the proven SCADAPack 300 platform, the SCADAPack 330 and 334 feature high-performance 32-bit processing, highspeed LAN, serial and USB communications, integrated
More informationXRC G Panel Mount XSeries G4 Products Remote Controller
Data Sheet XRC G4 6990 Panel Mount XSeries G4 Products Remote Controller INTRODUCTION XSeries G4 devices, from the Totalflow division of ABB provide functionality only possible through the convergence
More informationProduct Data: Micro MV 100
The Micro MV 100 is a three meter bi-directional field mounted flow computer which can be used for all liquid and gas applications, including custody or non-custody measurements. The Micro MV 100 flow
More informationSelf-Powered Wireless Instrumentation
Self-Powered Wireless Instrumentation Accutech Rapid deploy wireless instrumentation solutions for telemetry and remote SCADA Cost-Effective Solutions for Challenging Applications 03 Knowledge of your
More informationLineGuard Specification Sheet Issued 8/24/10 VA Revision 0. Valve Automation
LineGuard 2300 The LineGuard 2300 Electronic linebreak detection system monitors natural gas pipeline pressure and rate of pressure drop, and can provide manual or automatic control of a single valve actuator
More informationMST2000 Loop Powered Multivariable SMARTFLOW Transmitter
MST2000 Loop Powered Multivariable SMARTFLOW Transmitter MST2000 Loop Powered Multivariable SMARTFLOW Transmitter Brandt Instruments MST2000 Series Loop Powered Multivariable SMARTFLOW Transmitter sets
More informationAPP 700 Technical Specification
Issued: 12/12 Supersedes: 4/12 Description The APP 700 hardware series are especially designed for waste and clean water systems, both in construction and functionality. The RTUs¹ are developed to meet
More informationMMT330 Series Moisture and Temperature Transmitters for Oil
MMT330 Series Moisture and Temperature Transmitters for Oil Features Continuous online measurement of moisture in oil Ball-valve installation no need to shut down the process or drain the oil Proven Vaisala
More informationPTU300 Combined Pressure, Humidity and Temperature Transmitter
PTU300 Combined Pressure, Humidity and Temperature Transmitter For Demanding Applications Features Barometric pressure, humidity, and temperature measurement in one transmitter RS-232C serial interface
More informationPioneer Petrotech Services Inc. Proudly Canadian. PPS33 & 33LR RemoteWatcher Multi-Sensor Wireless Monitoring System.
Pioneer Petrotech Services Inc. Proudly Canadian PPS33 & 33LR RemoteWatcher Multi-Sensor Wireless Monitoring System www.pioneerps.com PPS33 & 33LR RemoteWatcher PPS33 RemoteWatcher is a low-power multisensor
More informationEPWR Series. RoHS. Product Description. Available Products. Installation Instructions 01
01 Series RoHS Compliant Product Description The Series remote pressure transducers are designed for differential pressure applications. The sensors are remotely installed on existing plumbing runs. The
More informationSeries TFXB Ultra. Transit Time Ultrasonic Flow Meter, Clamp-on, Liquid, Single-Channel
Series TFXB Ultra Transit Time Ultrasonic Flow Meter, Clamp-on, Liquid, Single-Channel Part 1. General 1.1 Scope A. This section describes the requirements for an ultrasonic flow measurement transmitter
More informationYokogawa Y-Flow Master Database 62102
Instruction Manual IM 04Q01A04-01E-A Yokogawa Y-Flow Master Database 62102 Yokogawa Y-Flow Master Database 62102 Yokogawa Corporation of America 2 Dart Road, Newnan, Georgia U.S.A. 30265 Tel: 1-800-258-2552
More informationMODCELL 2050R Single Loop Controllers
Isolated universal process and remote set-point input Four internal set-points No jumpers required to define instrument parameters Ratio/bias on process and remote set-point Totalizer Ramp/soak profile
More informationPCS Ferguson 8000 Series Overview Manual. The PCS Ferguson 8000 Series brand is trademarked by PCS Ferguson.
The PCS Ferguson 8000 Series brand is trademarked by PCS Ferguson. These documents and materials are copyrighted by PCS Ferguson. 2016 All rights reserved. For information contact: PCS Ferguson 3771 Eureka
More informationWI-I/O 9 Multi I/O Units
WI-I/O 9 Multi I/O Units A transceiver is a wireless device made up of a transmitter and receiver. Since each module can manage both input and output signals, it can be used to monitor transducers and
More informationSCADAPack 350E 357E. Smart Remote Terminal Unit
SCADAPack 350E 357E Smart Remote Terminal Unit 1 The SCADAPack 300E Smart RTU is a platform built on a 32-bit processor and fitted with a 12-30 Vdc supply, various communication links and a wide range
More informationAndover ContinuumTM Infinet II
Andover ContinuumTM Infinet II The i80 Series controllers are designed for control of Air Handling Units, Roof Top Units, and other mechanical plant equipment. Features 0 Choose the i80 model with the
More informationBACnet. b3810 Series Local Controllers
BACnet b380 Series Local Controllers The Andover Continuum TM b380 series controllers are designed for control of Air Handling Units, Roof Top Units, and other mechanical plant equipment. 0 Features Choose
More informationHMISCU6B5 3 5 color touch controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out
Characteristics 3 5 color touch controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out Main Range of product Product or component type Display size Display type Pixel resolution Touch panel Offer Sustainability
More informationFeatures. IDS : Inclinometer Display System with RS232 Output
Graphic Dual Axis Mode Dual Axis Mode Features Single Axis Mode Description Features The IDS is a high quality display system for use with many of our inclinometer sensors. It has a sturdy Aluminium housing
More informationScanner 2000 microefm
NUFLO Scanner 2000 microefm Flow Computer Data Logger Multi-variable Transmitter PID Controller Mounts directly to turbine meters, orifice meters and cone meters The Scanner 2000 microefm is among the
More informationHMISBC Rear Module controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out
Characteristics Rear Module controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out Main Range of product Product or component type Complementary Supply [Us] rated supply voltage Immunity to microbreaks
More informationXFC 6410, XFC 6413, and XFC 6713 XSeries Products Differential Flow Computer
Data Sheet XSeries Products Differential Flow Computer INTRODUCTION XSeries devices, from the Totalflow division of ABB, provide functionality only possible through the convergence of RTU, PLC and flow
More informationXFC 6411, XFC 6414, and XFC 6714 XSeries Products Linear Flow Computer
Data Sheet XFC 6411, XFC 6414, and XFC 6714 XSeries Products Linear Flow Computer INTRODUCTION XSeries devices, from the Totalflow division of ABB provide functionality only possible through the convergence
More informationTechnical data sheet. PowerLogic power-monitoring units EM3500 series DIN Rail meter
Technical data sheet PowerLogic power-monitoring units series DIN Rail meter The Series DIN Rail Meter combines exceptional performance and easy installation to deliver a cost-effective solution for power
More informationLAUREL ELECTRONICS, INC.
LAUREL ELECTRONICS, INC. Laureate RTD Temperature Panel Meter / Controller Features Factory calibrated for 100Ω platinum, 10Ω copper & 120Ω nickel RTDs 2, 3 or 4-wire connection with lead resistance compensation
More informationXRC 6490, XRC 6790, and XRC 6890 XSeries Products Remote Controller
Data Sheet XRC 6490, XRC 6790, and XRC 6890 XSeries Products Remote Controller INTRODUCTION XSeries devices, from the Totalflow division of ABB provide functionality only possible through the convergence
More informationSCADAPack 32. Smart RTU
SCADAPack 32 Smart RTU 1 Compared to the SCADAPack 300 platform, the SCADAPack 32 is a higher performance Smart RTU built to meet the demands of larger applications including support for up to 10 gas flow
More informationHMISBC Rear Module controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out
Product data sheet Characteristics HMISBC Rear Module controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out Main Range of product Product or component type Device presentation Complementary Supply
More informationLevel instruments. Communications and Displays SITRANS RD200. 5/306 Siemens FI Technical specifications. Overview
Overview The is a universal input, panel mount remote digital display for process instrumentation. Benefits Easy setup and programming via front panel buttons or remotely using RD software Display readable
More informationGas Controller System DGC-06
Page 1 May 2016 Measuring, warning and controlling device series for toxic, combustible and refrigerant gases and vapours. The gas controller series DGC-06 is designed in accordance with the standard EN
More informationFloBoss 107 Flow Manager
FB107 Product Data Sheet D301233X012 August 2017 FloBoss 107 Flow Manager The FloBoss 107 Flow Manager (FB107) is a microprocessorbased controller that monitors, measures, and controls equipment in a remote
More informationCDD4 Duct Carbon Dioxide Transmitter
Drill or punch a 1-1/8 or 1-1/4 hole in the duct at the preferred location and insert the probe into the hole to mark the enclosure mounting holes. Remove the unit and drill the four mounting holes. Clean
More informationMulti-Point Gas Detection and Control System
Multi-Point Gas Detection and Control System DESCRIPTION Wall mounted, microprocessor-based, multi-point, analog electronic control system for various gas, temperature and humidity detection, control and
More informationPhone: Fax: For calls outside the US please call:
SM320 Phone: 1-800-757-3747 Fax: 1-800-676-0498 Email: dicksoncsr@dicksondata.com For calls outside the US please call: 1-630-543-3747 Display Temperature Data Logger Specifications Alarm Type: Audio/Visual
More informationHMIGK5310 Keypad-touchscreen panel color x 480 pixels VGA -10.4" - TFT LCD
Characteristics Keypad-touchscreen panel color - 640 x 480 pixels VGA -10.4" - TFT LCD Main Range of product Product or component type Display colour Display size Supply Operating system Processor name
More informationDMT340 Series Dewpoint and Temperature Transmitters for Very Dry Conditions
www.vaisala.com DMT340 Series Dewpoint and Temperature Transmitters for Very Dry Conditions The display shows measurement trends, real-time data, and measurement history. Features/Benefits Measures dew
More informationMulti-Point Gas Detection and Control System
Multi-Point Gas Detection and Control System Specifications subject to change without notice. USA 40804 Page of 7 DESCRIPTION Wall mounted, microprocessor-based, multi-point, analog electronic control
More informationI/A Series Remote Terminal Unit (RTU) RTU 20 for Oil, Gas, and Water SCADA Applications
I/A Series Remote Terminal Unit (RTU) RTU 20 for Oil, Gas, and Water SCADA Applications RTU 20 OVERVIEW The I/A Series RTU 20 is an Intelligent Remote Device capable of performing a full range of control
More informationHMISCU6B5. Main. 60 right 40 top 60 bottom
Product datasheet Characteristics HMISCU6B5 Main Range of product Product or component type Display size Display type Touch panel Device presentation Magelis SCU Small touch HMI controller 3.5 inch With
More informationAndover ContinuumTM. b3850 Series Terminal Controllers
TM b3850 Series Terminal Controllers The TM b3850 series controllers are native BACnet controllers that communicate on an RS-485 field bus as Master devices using the MS/TP BACnet protocol. 02 Features
More informationDMT345 and DMT346 Dewpoint Transmitters
DMT345 and DMT346 Dewpoint Transmitters for High Temperature Applications Features DMT345 measures humidity at temperatures up to 180 C (356 F) DMT346 measures humidity at temperatures up to 350 C (+662
More informationAndover ContinuumTM Infinet II
Andover ContinuumTM Infinet II i2920 System Controllers The Andover Continuum Infinet II i2920 System Controller is designed to meet the needs of your most demanding control and monitoring applications
More informationOnline data sheet. Flow-X FLOW COMPUTER
Online data sheet A B C D E F H I J K L M N O P Q R S T Ordering information Type Part no. On request The exact device specifications and performance data of the product may deviate from the information
More informationXFC G4 XSeries G4 Products Linear Flow Computer
Data Sheet XFC G4 XSeries G4 Products Linear Flow Computer INTRODUCTION XSeries G4 devices, from the Totalflow division of ABB provide functionality only possible through the convergence of RTU, PLC and
More information/8 DIN Universal Process Indicator
Data Sheet SS/_ High visibility LED display the clearest view of your process status.% measurement accuracy precise indication of process measurement Analog and relay outputs as standard alarm and retransmission
More informationLAUREL. Laureate RTD Temperature Panel Meter / Controller ELECTRONICS, INC. Features. Description. Specifications
LAUREL ELECTRONICS, INC. Laureate RTD Temperature Panel Meter / Controller Features Factory calibrated for 100Ω platinum, 10Ω copper & 120Ω nickel RTDs 2, 3 or 4-wire connection with lead resistance compensation
More informationHTZ. Description. Features. Smart HART Humidity and Temperature Transmitter
March 2018 Description The HTZ Smart HART Transmitter simultaneously measures humidity and temperature in industrial, commercial, manufacturing, and HVAC applications. Based on the humidity and temperature
More informationDTM Distributed Transmitter Monitor
Distributed Transmitter Monitor 96 Communication Module The 96 functions as an RS232 to RS485 convertor and / or enables (32) modules to be networked together via Modbus. Combined with the -CFG configuration
More informationMicro Motion Model 7950 and Model 7951 Signal Converters
Product Data Sheet PS-001316, Rev. B April 2013 Micro Motion Model 7950 and Model 7951 Signal Converters Micro Motion Model 7950 and Model 7951 signal converters are the perfect complement to Micro Motion
More informationY800 Plus Frequency, Rate & Period Meter With dual, independently field-scalable channels
Y800 Plus Frequency, Rate & Period Meter With dual, independently field-scalable channels Description Features Frequencies from 0.005 Hz to 1 MHz 6-digit resolution at update rates up to 25/s Selectable
More informationFamily of Water Cut Analyzers
Phase Dynamics Technology for Precision Measurements Phase Dynamics, Inc. 1251 Columbia Drive Richardson, TX 75081 USA E-Mail sales@phasedynamics.com Tel: 972-680-1550 Fax: 972-680-3262 Family of Water
More information3000 SERIES LOW PROFILE FLOOR SCALE.
3000 SERIES LOW PROFILE FLOOR SCALE www.nascoop.com 3000 SERIES LOW PROFILE FLOOR SCALE An Economical Choice Offering Exceptional Performance The Summit 3000 Series provides exceptional performance in
More informationSCADAPack 312E 313E. Smart RTUs for water
SCADAPack 312E 313E Smart RTUs for water 1 SCADAPack 312E and 313E Smart RTUs feature 32-bit processing, serial and US communications, integrated 12-30Vdc power supply, advanced power-management and a
More informationLocal LCD HMI - View and force I/O, and make simple configuration changes without a computer!
Product Data Sheet A part of the new PINNACLE family Ascent I/O Smart Distributed & Peer-to-Peer I/O Wireless, Serial, and Ethernet/Internet Modular I/O for SCADA and DCS systems cost-effective monitoring
More informationFlow Measurement SITRANS F US Clamp-on
Overview SITRANS FUG1010 clamp-on non-intrusive ultrasonic flow transmitter is ideal for natural and process gas applications, including checkmetering, allocation, production, storage and gas fired power
More informationHigh Voltage DC Meter
High Voltage DC Meter Javelin D PD644 0-300 VDC input NEMA 4X, IP65 front Scale in engineering units Sunlight readable LED display 4-20 ma analog output Two form C 3 A relays option RS-485 serial communications
More informationBACnet. b3867 Terminal Controllers
BACnet b3867 Terminal Controllers The Andover Continuum TM b3867 is a native BACnet controller that communicates on an RS-485 field bus as a Master device using the MS/TP BACnet protocol. 02 Features Product
More informationWHIRLYBIRD AUTOMATIC WEATHER STATION. Whirlybird Electronics Pvt Ltd 140, 2 nd Cross 13 th Main, BTM-I Bangalore
WHIRLYBIRD AUTOMATIC WEATHER STATION Whirlybird Electronics Pvt Ltd 140, 2 nd Cross 13 th Main, BTM-I Bangalore 560029 WHIRLYBIRD WWS-A is an Automatic weather station you can count on for reliable and
More informationQuantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III
Compact DC Drive Package The delivers a DC drive package that integrates the intelligence of the Mentor II with a space saving design that incorporates many accessories typically required in the North
More informationFB2100 Flow Computer. Mobile SCADA with Wi-Fi. Features. Product Data Sheet D301791X012 March Remote Automation Solutions
FB2100 Product Data Sheet D301791X012 March 2018 FB2100 Flow Computer The FB2100 is a cost-effective low-power field mount flow computer that measures and monitors gas flow for a differential or linear
More informationFloBoss TM 107/107E Flow Manager Overview
FloBoss TM 107/107E Flow Manager Overview New Technology New Features and Benefits. 1of 39 Introducing the FloBoss 107 The FloBoss 107 Flow Manager introduces a new technology platform to the FloBoss family
More informationiologik E1200 Series Ethernet remote I/O with 2-port Ethernet switch Introduction Remote I/O Daisy-Chained Ethernet I/O Connection
iologik E1200 Series Ethernet remote I/O with 2-port Ethernet switch User-definable Modbus/TCP Slave addressing Supports EtherNet/IP* adapter mode Supports RESTful API for IIoT applications 2-port Ethernet
More informationMeter Scanner & Controller
Meter Scanner & Controller CHART http://192.168.1.200 wiseries Save Current Graph Min / Max Temp 48.0/21.0 C hpa 50 1200 100% P1 Process A1 Ambient P2 Sensor 2 A2 Sensor 2 P3 Process A3 Ambient P4 Process
More informationSCADAPack Modbus multivariable transmitter
Modbus multivariable transmitter The SCADAPack 4102 Modbus Multivariable Transmitter provides precise measurement of static pressure, differential pressure and temperature; and features an optional display
More informationUnitary Controller. Features. Description. Technical Specification Sheet Rev. 6, March, 2000
Technical Specification Sheet Rev. 6, March, 2000 Unitary Controller The Unitary Controller can operate as an independent stand-alone controller, or can be connected to the APOGEE Automation System via
More informationSimplified information where and how you want it.
ConsolIdator 4 & 8 Multi-channel controllers Simplified information where and how you want it. ConsoliDator 4 Model PD940 ConsoliDator ConsoliDator 4 Features Four 4-20 Inputs Four 4-20 Outputs ConsoliDator
More informationSCADAPack Modbus multivariable transmitter
SCADAPack 4102 Modbus multivariable transmitter 1 The SCADAPack 4102 Modbus Multivariable Transmitter is the flagship of our Ethernet transmitter product line, offering precise measurement of process pressure,
More informationThe IQ300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.
IQ300 Wall Mount Load Cell Indicator Data sheet English 1.01 Introduction The IQ300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications. The high
More informationAndover Continuum Infinet II i2865/866 VAV Controllers with Built-in Actuator
Andover Continuum Infinet II i2865/866 VAV Controllers with Built-in Actuator The i2865 and i2866 are unique, low-cost VAV box controllers that come equipped with a built-in actuator to streamline hardware
More informationPM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features
PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER The PM174 is a compact, multi-function, three-phase AC powermeter and power quality analyzer specially designed to meet the requirements of users ranging
More informationHIGH-VOLTAGE DC METER
HIGH-VOLTAGE DC METER Javelin D PD644 0-300 VDC input NEMA 4X, IP65 front Scale in engineering units Sunlight readable LED display 4-20 ma analog output Two form C 3 A relays option RS-485 serial communications
More informationiologik E2200 Series Smart Ethernet remote I/O with Click&GO Logic Introduction Remote I/O PC-Free Alarm and Control Intelligence
iologik E2200 Series Smart Ethernet remote I/O with Click&GO Logic Active communication with patented MX-AOPC UA Server and Active OPC server Smart alarm management with email, SNMP traps, TCP, UDP Save
More informationXBTGC2330T 5 7 LCD TFT color controller panel - 16 inputs/16 outputs source
Characteristics 5 7 LCD TFT color controller panel - 16 inputs/16 outputs source Complementary Backlight lifespan Brightness Contrast Character font Inrush current Power consumption Local signalling Number
More informationiologik 2500 Series Quick Installation Guide
iologik 2500 Series Quick Installation Guide Smart Remote I/O Edition 5.0, December 2016 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777
More informationMulti-Point Gas Detection and Control System
Multi-Point Gas Detection and Control System Specifications subject to change without notice. USA 50729 Page of 9 DESCRIPTION Wall mounted, microprocessor-based, multi-point, analog electronic control
More informationTRANSMITTERS. HygroFlex & HygroClip-EX. Applications. Highlights
HygroFlex & HygroClip-EX HygroFlex series may be used together with the intrinsically safe HygroClip-EX probes. The relative humidity and temperature can be displayed and output as analog signals. Calculated
More informationSCADAPack 350E 357E. Smart Remote Terminal Units. Distributed by Relevant Solutions relevantsolutions.com
Smart Remote Terminal Units The SCDPack 300E Smart RTU is a platform built on a 32-bit processor and fitted with a 12...30 Vdc supply, various communication links and a wide range of analog and digital
More informationVC211L ELECTRONIC VOLUME CORRECTOR.
www.sys-inc.com Approved by NMI for legal metrology EN 12405 compliant AGA 5, AGA 7, AGA 8, GERG, ISO 6976 calculations Complies with ISO 12213-3 Certified for use in hazardous locations The VC211L is
More informationGeneral information. Display. Supply voltage. Input current
Data sheet SIMATIC S7-1200, CPU 1215C, COMPACT CPU, AC/DC/RELAY, 2 PROFINET PORT, ONBOARD I/O: 14 DI 24V DC; 10 DO RELAY 2A, 2 AI 0-10V DC, 2 AO 0-20MA DC, POWER SUPPLY: AC 85-264 V AC AT 47-63 HZ, PROGRAM/DATA
More informationAndover ContinuumTM Infinet II
Andover ContinuumTM Infinet II i2850 Series The i2850, i2851, and i2853 controllers provide cost-effective DDC control of individual terminal units (e.g. VAV boxes, fan-powered induction units, unit ventilators,
More informationRedundant System Redundant System P9-1-1
.. P-- Overview - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - P-- idcs-8830/idcs-8830r - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
More informationPDW30 Point-To-Point Wireless Bridge
PDW30 Point-To-Point Wireless Bridge WIRELESS WIreless System FEATURES Wire Replacement in a Rugged, Industrial Housing Inputs and Outputs on Both Field Units Simple to Order, Configure, & Install 1 Mile
More informationSystem Components Guide
System Components Guide 2011 Version 1.0 Gemini NavSoft Technologies Ltd. Fredericton, NB, Canada http://www.gemini-navsoft.com GNT GPS Position Solver is used to generate mm level accuracy, GPS position
More informationTemperature and Humidity Sensor
Temperature and Humidity Sensor M12FTH4Q and M12FT4Q A simple way to verify conditions in locations that were once too difficult to access via traditional monitoring methods. With no software required,
More informationNokeval. Where accuracy counts... Product Summary 2005 for Wireless Transmitters
Where accuracy counts... Product Suary 2005 for Wireless Transmitters 11102005 Wireless Data Acquisition Systems Can data logging be that easy! Place the into the target and start the logger in PC. Every
More informationFeatures and Benefits. Certifications
iologik R1200 Series RS-485 remote I/O Features and Benefits Dual RS-485 remote I/O with built-in repeater Supports the installation of multidrop communications parameters Install communications parameters
More informationYokogawa Y-Flow Y-Flow and Accessories
Instruction Manual IM 04Q01A02-01E-A Yokogawa Y-Flow and Accessories Yokogawa Y-Flow Y-Flow and Accessories Yokogawa Corporation of America 2 Dart Road, Newnan, Georgia U.S.A. 30265 Tel: 1-800-888-6400
More informationHMISCU6A5 3 5 color touch controller panel - Dig 16 inputs/10 outputs
Characteristics 3 5 color touch controller panel - Dig 16 inputs/10 outputs Main Range of product Product or component type Display size Display type Pixel resolution Touch panel Offer Sustainability Sustainable
More informationCarbon Monoxide (CO) Gas Detection and Control System
Carbon Monoxide (CO) Gas Detection and Control System DESCRIPTION Gas monitor with built-in carbon monoxide (CO) sensor, wall-mounted, accepts inputs from remote devices such as other gas sensors, temperature
More informationTOTALFLOW Technical Bulletin 109
TOTALFLOW Technical Bulletin 109 Phase-Out and Upgrade Options for the Model 6600 Flow Computer Unit Totalflow Technical Bulletin Version 1.0, Revision AC (14 May 2004) Introduction The model 6600 Flow
More informationHMIGTO6315 advanced touchscreen panel stainless 800 x 600 pixels SVGA- 12.1" TFT - 96 MB
Product data sheet Characteristics HMIGTO6315 advanced touchscreen panel stainless 800 x 600 pixels SVGA- 12.1" TFT - 96 MB Main Range of product Product or component type Display colour Display size Supply
More informationAndover ContinuumTM b3865/866 VAV Controllers with Built-in Actuator
Andover ContinuumTM b3865/866 VAV Controllers The Andover Continuum TM b3865 and b3866 are native BACnet controllers that communicate on an RS-485 field bus as Master devices using the MS/TP BACnet protocol.