1 Installation Guide / Ver. C

2 Contents.... General... 2 Board Description Installation Mounting Opening the Housing Mounting together with other Units Wiring Runs Addressing Selection of A or B-Bus Connecting Supply Voltage and Buses Connection to External Equipment RS232C Communication with External Unit RS422 Communication Data Link Communication RS485 Communication Connecting AUX Inputs and AUX Outputs Switch SW Installation Test Procedure... 6 Circuit Board Replacement / Ver. C

3 Figure... General T942SI is a serial interface that is used to connect external equipment to On Site Paging System and System T942SI is designed to communicate with the external unit via an interface of type RS232C, RS422, or RS485. The interfaces are galvanically isolated for up to 500 V. All the inputs and outputs have transient protection, and all bus connections are equipped with chokes for increased EMC protection. As a complement to this installation guide see also the applicable system installation document: TD 90227GB for system 900 or TD 920GB for system Supply voltage: 2.5 V DC ± 0% Current consumption: Max 500 ma Delivery includes: T942SI Modular system bus cable Optional equipment that may be required: If T942SI is to be used for speech pagings, speech module T94SM must be mounted on the T942SI circuit board. If the external unit is to be connected to 8-pin modular connector J09 on the T942SI for RS232C communication, adapters can be ordered from ATAB for 9-pin and 25-pin D-sub connectors. See 4. RS232C Communication with External Unit on page 8. Tools, etc., required: Screwdriver Cutting pliers Screws for installation Multimeter / Ver. C

4 Soldering iron and solder 2 Board Description S02 LEDO4 LEDO LEDO5 ICO SWO IC5 IC4 ICO8 IC32 S04 SWO2 8 J04 LEDO2 LEDO3 BAT S03 S06 S07 S05 S08 S09 J0 J02 J09 J03 6 J07 6 J08 5 Figure 2. Circuit board T942SI. Connectors J0, J02: Modular jacks for connection of system bus cabling. J03: Supply voltage. Also for connection of A or B-bus via twisted-pair wiring when modular bus cabling cannot be used / Ver. C 2

5 J04: Connects speech module T94SM. J07: Connects AUX Input and AUX Output. J08: Connects external computer with RS422/RS485 interface. J09: Modular jack for connection of external computer with RS232C interface. Jumpers S02: Jumper points used for software development. S03: Jumper points used to connect battery. S04: Jumper points used for Mbit RAM. S05: Jumper points used to convert from RS422/RS485 to RS232C. S06: Jumper points used for RS485 interface. S07: Jumper points used for RS422 interface. S08, S09: Jumper points used to connect to B-bus. Switches SW0: SW02: LEDs LED0A LED0B LED02: LED03: LED04: LED05: IC-Circuits IC0: IC08: IC4, IC32: IC5: 8-section address selector switch. 8-section selector switch used to set various parameters for hardware tests, etc. Normally all sections are set to OFF. Green function indicator. Red function indicator. Indicates during paging. Not used. Indicates during transmission to external computer. Indicates during reception from external computer. Microprocessor, type 80C88EB. Module key. 4 Mbit FLASH PROMs, program memory. RAM memory with battery backup. It can be either Mbit or 4 Mbit / Ver. C 3

6 3 Installation 3. Mounting T942SI should be placed in a dry environment with a temperature range of 0 to +40ºC. Dimensions (H x W x D) 275 x 30 x 60 mm 56, , Figure 3. Mounting dimensions in mm. Note: To facilitate service after the unit is installed, we recommend a free space of about 50 mm below and 50 mm above the unit. 3.2 Opening the Housing Use a screwdriver or similar to release the cover by applying a light pressure to the two snap catches () and remove the cover (2). 2 Figure 4. Realising the cover / Ver. C 4

7 3.3 Mounting together with other Units Figure 5. Mounting with other units. Remove upper and lower covers. The lower rectangular covers are used to fasten units to each other (). 2 Fasten the output module with three screws, see 3. Mounting on page Wiring Runs The plastic partition (shaded in the illustration) is scored to facilitate breaking at convenient intervals Slots Figure 6. Wiring of modular or twisted pair cabling, () and (2). Use pliers to break off a suitable section. 2 Run the wiring out through the partition. 3 Use the slots at the opening to secure the wiring with cable straps / Ver. C 5

8 Wiring can be run four ways for connection with other units: Figure 7. Four ways of wiring runs. Remove the rectangular covers and run the cabling out through the side (). Break off sections at short side of case and run the cabling downwards (2). Run the cabling through the round holes at the bottom of the case (3). Remove the circular covers at the top of the side case (4). 3.5 Addressing Select the proper address by setting address selector switch SW0 (see the document System Installation, under Addressing). The address must not be 00 nor the same as any other system unit. OFF ON SW0 8 Figure 8. Addressing on T942SI / Ver. C 6

9 3.6 Selection of A or B-Bus R092 S08 R093 S09 Figure 9. Position of the 0 ohm resistors and jumpering points. A-bus is normally used (always used in CTS 900). To use B-bus: Remove the 0 ohm resistors R092, R093 from the circuit board and solder together jumper points S08 and S09. See figure Connecting Supply Voltage and Buses Supply voltage in Supply voltage out A or B-bus J03 +2V 2 GND BUS 6 BUS 2 Figure 0. Connector J03. Connect the supply voltage to screw and 2 of screw connector J03. (See also the document System Installation, under Power Supply.) 2 Connect modular bus cabling to J0 and J02, and/or A or B-bus to J03 screw 5 and 6. Note: The data lines are polarized. Use only twisted-pairs for two-wire connections! 4 Connection to External Equipment The external unit is to be connected to J09 on the T942SI for RS232C communication, or to J08 for RS422/RS485 communication. Note: The T942SI is configured for RS232C communication at delivery from the factory / Ver. C 7

10 4. RS232C Communication with External Unit Connect the external unit to the 8-pin modular connector J09 on the T942SI according to the applicable drawing below. Connects directly to external unit with RS232C Interface 9-pin female D-sub connector RX 2 TX 3 DTR 4 GND CTS 8 9 J09 T942SI (not used) 2 TX 3 RX 4 CTRL IN 5 CTRL OUT 6 (not used) 7 GND 8 (not used) Figure. Connection to a 9-pin female D-sub connector. Note: Modems with 25-pin D-sub connectors, the RTS and CTS signals must be jumpered - i.e. pin 4 to 5. Connects via modem to external unit with RS232C Interface 25-pin male D-sub connector TX 2 RX 3 RTS 4 CTS 5 6 GND 7 DCD 8 J09 T942SI (not used) 2 TX 3 RX 4 CTRL IN 5 CTRL OUT 6 (not used) 7 GND 8 (not used) DTR Figure 2. Connection to a 25-pin male D-sub connector. Adapters with the correct connections can be ordered from ATAB for both the 9-pin and 25-pin D-sub connectors / Ver. C 8

11 4.2 RS422 Communication S06 S07 S05 R065 S03 S04 S06 S07 S05 R065 S08 S09 J09 J08 J07 J0 J02 J09 J03 6 J07 6 J08 5 Figure 3. Resistor R065 and soldering points S05-S07. Disable the RS232C interface by removing 0 ohm resistor R Solder together jumper points S07. 3 Connect the external unit to J08. to exernal unit using RS422 communication Rb Ra Tb Ta J08 Tb 2 Ta 3 Rb 4 Ra 5 GND Figure 4. Connection of external unit to J08 using RS422 connection. Note: If the RS232C interface is to be used in the future it can be restored by soldering together jumper points S Data Link Communication Connect the external unit according to figure 4 on page 9, RS422 Communication. After start-up, if function indicator, LED0 flashes green at a slow intervals, the connection of the Data Link is incorrect. 4.4 RS485 Communication Disable the RS232C interface by removing 0 ohm resistor R065. See figure 3 on page 9. 2 Solder together jumper points S06. See figure 3 on page / Ver. C 9

12 3 Connect the external unit to J08. to exernal unit using RS485 communication Rb/Tb Ra/Ta J08 Tb 2 Ta 3 Rb 4 Ra 5 GND Figure 5. Connection of external unit to J08 using RS485 connection. Note: If the RS232C interface is to be used in the future it can be restored by soldering together jumper points S05. See figure 3 on page Connecting AUX Inputs and AUX Outputs Two digital inputs and two digital outputs can be connected via J07. The output signals are dimensioned for 00 ma at max 2 V. J07 External +2 V 2 IN 3 IN2 4 OUT 5 OUT 2 6 External 0 Vdc Figure 6. Connector J07. Galvanic isolation of the inputs and outputs is provided by using a separate power supply. When galvanic isolation is not needed, supply voltage can be taken from the T942SI circuit board by connecting J07: to J03:3 and J07:6 to J03: Switch SW02 Normally all 8 sections of SW02 are set to OFF. When the setting of any section is changed, the Central Unit must be restarted to make the change effective. Switch settings to hexadecimal values between 80H and FFH are reserved for hardware testing. Section : Section 2: Section 3: Section 4: Section 5: Section 6: Used to sent module information to the Central Logger of the WinBK. ON = Send OFF = Do not Send Not used, must be set to OFF. Not used, must be set to OFF. Not used, must be set to OFF. Used to set the module in programmable mode. Used only by PSP2 protocol. ON = Programmable Mode; OFF = Normal (Operational) Mode. Not used, must be set to OFF / Ver. C 0

13 Section 7: Section 8: Not used, must be set to OFF. Not used, must be set to OFF. 5 Installation Test Procedure Check that SW0 is set to the correct address and SW02 is set for desired parameters, and that module key IC08 is installed. 2 Energize all the units in the On Site Paging System. Function indicator LED0 on T942SI should light red for about second and then go over to a flashing orange. If it continues to indicate with a steady red check that supply voltage is 2.5 V DC ± 0%. Flashing indicates a fault as follows: Colour ON OFF Fault red 00 ms 800 ms Incorrect software license red 800 ms 00 ms Parameter fault red s s Watchdog reset green 00 ms 800 ms No Data-link connection Function indicator Figure 7. Function indicator. 3 If the T942SI is connected to a central unit the indicator should show a steady green indication within 90 seconds. If the indicator continues to blink orange, check: Polarity Connections on the T942SI circuit board. T942SI is properly addressed. If everything seems to be OK but the function indicator still blinks, the fault is probably located outside the T942SI module. Check the other system units according to the document System Installation or contact your dealer / Ver. C

14 4 Replace the cover. When all other units are installed perform the system test described in the applicable System Installation document: TD 90227GB for system 900 or TD 920GB for system Circuit Board Replacement Deenergize the unit. 2 Remove the cover. 3 Lift off the screw connectors from the circuit board. 4 Press the four holding clips to release the circuit board () and release the circuit board (2), (3). The heat sink is mounted on the circuit board and is replaced simultaneously. 3 2 Figure 8. Removing the circuit board. 5 Install the new circuit board in the case and make sure the board clicks into position. 6 Set all switches and jumpers as they were on the old circuit board and replace the connectors. 7 Remove the module key from the old circuit board and install it on the new circuit board. 8 Reinstall the applicable software. 9 Check installation according to 5 Installation Test Procedure on page / Ver. C 2

icex-cmtm General specs and Installation guide

icex-cmtm General specs and Installation guide icex-cmtm General specs and Installation guide 1. General view 2. Specifications 2.1. Common specs: Ethernet 1 x 10/100Base/T, RJ45 connector with traffic and link LED Serial Interface 1 x RS232/485 USB

More information

ISOLATED RS-232 TO RS-422/485 CONVERTER

ISOLATED RS-232 TO RS-422/485 CONVERTER QUICK START GUIDE ICD400A ISOLATED RS-232 TO RS-422/485 CONVERTER 24/7 TECHNICAL SUPPORT AT 877.877.2269 OR VISIT BLACKBOX.COM STEP 1 - Specifications Complies with FCC Class B and CE requirements. Withstands

More information

ICD105A 1008 page 1/ r001 ICD105A. Industrial RS-232 to RS-422/485 Converter

ICD105A 1008 page 1/ r001 ICD105A. Industrial RS-232 to RS-422/485 Converter ICD105A 1008 page 1/5 7319 r001 ICD105A Industrial RS-232 to RS-422/485 Converter Data Rates up to 115.2 Kbps 10 48 VDC Input Power Range Wide Operating Temperature 3-Way 2000V Optical Isolation Modbus

More information

Miniature Asynchronous 4-Wire High Speed Modems

Miniature Asynchronous 4-Wire High Speed Modems ME1862A-F ME1863A-F JULY 2003 ME1862A-M ME1863A-M Miniature Asynchronous 4-Wire High Speed Modems CUSTOMER SUPPORT INFORMATION Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500)

More information

RTU560 Remote Terminal Unit Connections and Settings

RTU560 Remote Terminal Unit Connections and Settings Remote Terminal Unit Connections and Settings Communication Unit 560CMG10 Application, characteristics and technical data have to be taken from the hardware data sheet: 560CMG10 1KGT 150 645 Operation

More information

SoundwebTM. Installation Guide

SoundwebTM. Installation Guide 105 SoundwebTM Soundweb TM 9000 Installation Guide Soundweb TM Regulatory Information An example of this equipment has been tested and found to comply with the following European and international Standards

More information

7I44 MANUAL 8 CHANNEL RS-422 INTERFACE

7I44 MANUAL 8 CHANNEL RS-422 INTERFACE 7I44 MANUAL 8 CHANNEL RS-422 INTERFACE V1.1 This page intentionally almost blank Table of Contents GENERAL.......................................................... 1 DESCRIPTION.................................................

More information

7I74 MANUAL 8 CHANNEL RS-422 INTERFACE

7I74 MANUAL 8 CHANNEL RS-422 INTERFACE 7I74 MANUAL 8 CHANNEL RS-422 INTERFACE V1.2 This page intentionally almost blank Table of Contents GENERAL.......................................................... 1 DESCRIPTION.................................................

More information

PCIe Card Selection Guide. PCIe-CAN Card. PCIe-COM Card. Taiwan Pulse Motion Co.,Ltd. Bus Interface PCI Express x 1 LPE-C122 PCE-C122D PCE-C122T

PCIe Card Selection Guide. PCIe-CAN Card. PCIe-COM Card. Taiwan Pulse Motion Co.,Ltd. Bus Interface PCI Express x 1 LPE-C122 PCE-C122D PCE-C122T PCIe Card Selection Guide PCIe-CAN Card Bus Interface PCI Express x 1 LPE-C122 PCE-C122D PCE-C122T Channels I/O Isolation Voltage Baud Rate Terminator Resistor I/O PIN Type 2 Max. 1 Mbps Jumper for 120

More information

Intelligent Devices IDI 1100 Series Technical Manual

Intelligent Devices IDI 1100 Series Technical Manual Intelligent Devices IDI 1100 Series 4411 Suwanee Dam Road, Suite 510 Suwanee, GA 30024 T: (770) 831-3370 support@intelligentdevicesinc.com Copyright 2011, Intelligent Devices, Inc. All Rights Reserved

More information

USER MANUAL MODEL 2017P MODEL 2017P60. RS-232 to 20mA and. RS-232 to 60mA Current Loop Converters

USER MANUAL MODEL 2017P MODEL 2017P60. RS-232 to 20mA and. RS-232 to 60mA Current Loop Converters USER MANUAL MODEL 2017P RS-232 to 20mA and MODEL 2017P60 RS-232 to 60mA Current Loop Converters 07M2017P-E Doc# 073051UE Revised 5/7/96 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 1.0

More information

Up to two expansion cards can be added; these cards may either add an additional 4 analogue or 8 digital inputs.

Up to two expansion cards can be added; these cards may either add an additional 4 analogue or 8 digital inputs. SA380TX-L Hardware The basic TX-L unit features: 4 digital inputs 2 analogue inputs 1 RS485 port 24v 2W auxiliary power supply GSM modem. An Ethernet port can be fitted as an option when ordering. Up to

More information

I-7560U/7561U/7563U. User Manual WARRANTY WARNING COPYRIGHT TRADEMARKS CONTACT US

I-7560U/7561U/7563U. User Manual WARRANTY WARNING COPYRIGHT TRADEMARKS CONTACT US I-7560U/7561U/7563U User Manual USB tto RS--232//422//485 Converrtterrss Verr.. 1..0,, Decc.. 2013 WARRANTY All products manufactured by ICP DAS are warranted against defective materials for a period of

More information

Converter Box Data Sheet

Converter Box Data Sheet Page 1 from 6 Functions of the converter box The converter box is used to adapt physically two interfaces and to separate them galvanicly. It is configured as follows: Two interface slots can be used to

More information

The modems are made in industrial 108mm wide aluminium housing for DIN rail mounting. UCM RS232 interface

The modems are made in industrial 108mm wide aluminium housing for DIN rail mounting. UCM RS232 interface DESCRIPTION The modems are a series of general-purpose industrial modems, which can be used for data communication through Public Switched Telephone Networks (PSTN). The modems can operate in 2-wire, full-duplex,

More information

Advant OCS. The Compact and Cost Effective Advant Controller. Advant Controller 210. Open Control System

Advant OCS. The Compact and Cost Effective Advant Controller. Advant Controller 210. Open Control System Advant OCS Open Control System Advant Controller 210 The Compact and Cost Effective Advant Controller Advant Controller 210 is a small, cost-effective system belonging to the Advant Controller family.

More information

RTU560 Connections and Settings DIN Rail RTU 560CIG10

RTU560 Connections and Settings DIN Rail RTU 560CIG10 Connections and Settings DIN Rail RTU 560CIG10 Application, characteristics and technical data have to be taken from the hardware data sheet: 560CIG10 1KGT 150 719 Operation The 560CIG10 is a DIN rail

More information

IC693PWR331 High Capacity Power Supply, 24 VDC Input

IC693PWR331 High Capacity Power Supply, 24 VDC Input IC693PWR331 High Capacity Power Supply, 24 VDC Input The Series 90-30 DC input High Capacity power supply (IC693PWR33) is a 30 watt wide range supply designed for 24 VDC nominal inputs. For applications

More information

Brief Instruction. 4.2 ISDN devices. 4.2 GSM devices MDH 502 MDH 536 MDH 506 MDH 512 MDH 542 MDH 522

Brief Instruction. 4.2 ISDN devices. 4.2 GSM devices MDH 502 MDH 536 MDH 506 MDH 512 MDH 542 MDH 522 4.2 ISDN devices 502 506 512 522 532 536 542 552 556 Voltage VDC 24 Current ma (24V) 60 60 70 90 90 100 80 100 110 Protection class (IP) 20 Range of use Dry Surroundings Temperatures (Plant) 0 50 C Temperatures

More information

3710 ACM 3750 PDC 3800 RTU. ISOCOM Communications Card Retrofit Instructions

3710 ACM 3750 PDC 3800 RTU. ISOCOM Communications Card Retrofit Instructions 3710 ACM 3750 PDC 3800 RTU ISOCOM Communications Card Retrofit Instructions Danger During normal operation of this device, hazardous voltages are present which can cause severe injury or death. These

More information

Manual Industry Interfaces

Manual Industry Interfaces Manual Industry Interfaces W&T Release. Type 0, 0 0, 00 0, 0 0, 0 Industry Interfaces 0/0 by Wiesemann & Theis GmbH Subject to errors and changes: Since we can make mistakes, none of our statements should

More information

RS-232 Industrial Media Converter

RS-232 Industrial Media Converter USER GUIDE The leader in rugged fiber optic technology. U-151 2018C-0327 Industrial Media Converter COMPACT, RUGGED & TEMPERATURE HARDENED Introduction This Industrial Serial Data media converter transports

More information

I/O Interface DNA300

I/O Interface DNA300 DNA300 OPERATIONS MANUAL 1 Ring Communications, Inc. Crisis Alert System I/O Interface DNA300 2 DNA300 OPERATIONS MANUAL 2006/06/13 DNA300 OPERATIONS MANUAL 3 Contents INTRODUCTION... 5 INSTALLATION...

More information

Expansion Module HZS 541-1S

Expansion Module HZS 541-1S Expansion Module HZS 541-1S 12.10.2015 Page 1 System Description The external HZS 541-1S expansion module provides users of biomass heating systems with additional 230 V AC relay outputs, analog inputs

More information

USER S MANUAL SI-700 SI EIA-232/ EIA-485 INTERFACE JUL / 05 SI-700 VERSION 1 FOUNDATION

USER S MANUAL SI-700 SI EIA-232/ EIA-485 INTERFACE JUL / 05 SI-700 VERSION 1 FOUNDATION USER S MANUAL SI-700 SI-700 - EIA-232/ EIA-485 INTERFACE JUL / 05 SI-700 VERSION 1 TM FOUNDATION S I 7 0 0 M E smar www.smar.com Specifications and information are subject to change without notice. Up-to-date

More information

Arm-based DIN-rail industrial computers with 4 serial ports, 2 LAN ports, 8 DI/DO, and VGA. Features and Benefits. Certifications

Arm-based DIN-rail industrial computers with 4 serial ports, 2 LAN ports, 8 DI/DO, and VGA. Features and Benefits. Certifications IA260 Series Arm-based DIN-rail industrial computers with 4 serial ports, 2 LAN ports, 8 DI/DO, and VGA Features and Benefits Cirrus Logic EP9315 Arm9 CPU, 200 MHz 128 MB RAM onboard, 32 MB flash disk

More information

Integriti 8-32 Zone LAN Expander Module Kit INSTALLATION MANUAL

Integriti 8-32 Zone LAN Expander Module Kit INSTALLATION MANUAL Revision 2.1 July. 2014 1 Integriti 8 32 Zone LAN Expander Module Kit P/N: 996005PCB&K For Rev. B PCB. INSTALLATION MANUAL Overview The Integriti 8 Zone Expander Module provides an additional 8 Zone inputs,

More information

T1K MODBUS Base Controller Specifications

T1K MODBUS Base Controller Specifications Base Controller 1 2 In This Chapter.... Base Controller Setting the DIP Switches Setting the Rotary Address Switches Port Pin out and Wiring RJ12 Serial Port Pin out and Wiring 2 2 Base Controller General

More information

485DRCI. Industrial RS-232 to RS-422/485 Converter B&B ELECTRONICS PRODUCT INFORMATION. Specifications Serial Technology

485DRCI. Industrial RS-232 to RS-422/485 Converter B&B ELECTRONICS PRODUCT INFORMATION. Specifications Serial Technology 485DRCI RS-232 RS-485 2-Wrie RS-422/485 4-Wire RS-232 CON. RS-422/485 CON. Data Rate Isolation Surge Protection Industrial Bus Source Input Voltage Power Consumption Connector p/n 7207r3 485DRCI-4108ds

More information

TOXALERT MODEL AIR 2000

TOXALERT MODEL AIR 2000 TOXALERT MODEL AIR 2000 NOTE: Toxalert s Model GVU-CO 2 Sensor is the same as the Air2000R. Microprocessor-based, Infrared Environmental CO 2 Sensor OPERATOR S MANUAL TOXALERT TM INTERNATIONAL INC. P.O.

More information

ARB-0612 Converter USB RS 232/422/485/485-4W/TTL Manual

ARB-0612 Converter USB RS 232/422/485/485-4W/TTL Manual Converter USB RS 232/422/485/485-4W/TTL Manual _v1_01 Update date: 10/2018r. 10/2018 _v1_01 1 Table of Contents Symbols & Marks...3 General installation and safety rules...3 1.Destination of device...4

More information

TCNM-ACBB1 Installation Manual

TCNM-ACBB1 Installation Manual The TCNM-ACBB1 is a connection box that can be used as an accessory to facilitate system connections for installation and device replacement of several Banner family reading devices. System cabling is

More information

VL BPC 100. Valueline configurable box PC. Data sheet 3063_en_E. 1 Description. 2 Features

VL BPC 100. Valueline configurable box PC. Data sheet 3063_en_E. 1 Description. 2 Features Valueline configurable box PC Data sheet 0_en_E Description PHOENIX CONTACT 0-07- Features The VL BPC 000 is a configurable box PC that can be mounted either directly on a wall or on a DIN rail. The VL

More information

VL BPC MINI. A configurable industrial computer platform Intel Atom Z510PT CMAT IPC Module Option [I28] AUTOMATION Data Sheet 2930_en_A.

VL BPC MINI. A configurable industrial computer platform Intel Atom Z510PT CMAT IPC Module Option [I28] AUTOMATION Data Sheet 2930_en_A. A configurable industrial computer platform Intel Atom Z0PT CMAT IPC Module Option [I8] AUTOMATION Data Sheet 90_en_A Description PHOENIX CONTACT 0-0-0 Features The VL BPC MINI is an embedded box PC and

More information

W&T Manual Interface modules W&T

W&T Manual Interface modules W&T Manual Subject to error and alteration Model 18801, 18811 18802, 18812 18803, 18813, 18833 18601, 18611 18602, 18612 18613, 18633 18401, 18411 18402, 18412 Release 1.7 43 09/2013 by Wiesemann und Theis

More information

Processor module DCP 642

Processor module DCP 642 Processor module DCP 642 The DCP 642 processor module executes the control program and constitutes a major part of the automation system. Since it has no internal power supply, the processor module has

More information

OnCell G3100 Series Quick Installation Guide

OnCell G3100 Series Quick Installation Guide OnCell G3100 Series Quick Installation Guide Edition 4.1, August 2016 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777 Fax: 1-714-528-6778

More information

Accessories IC690ACC900

Accessories IC690ACC900 (IC690ACC900) datasheet Features Provides the IC69* programmable controllers with an interface to devices that use the RS- interface. Allows connection to programming computer without a Work Station Interface

More information

Quick Start Installation Guide

Quick Start Installation Guide apc/l Quick Start Installation Guide Version A2 Document Part Number UM-201 May 2010 OVERVIEW The apc/l is an intelligent access control and alarm monitoring control panel which serves as a basic building

More information

INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual. PCMNET V 7. xx

INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual. PCMNET V 7. xx INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual PCMNET V 7. xx INTEGRATED SYSTEMS AND CONTROLS, INC. PCMNET Users Manual Revised 2/4/2005 2003-2005 Integrated Systems and Control. Inc. PO Box

More information

DCC-8 DIGITAL TO EIGHT CURRENT LOOP CONVERTER OPERATING MANUAL

DCC-8 DIGITAL TO EIGHT CURRENT LOOP CONVERTER OPERATING MANUAL DCC-8 DIGITAL TO EIGHT CURRENT LOOP CONVERTER OPERATING MANUAL 1 TABLE OF CONTENTS 1. MOUNTING INSTRUCTIONS 1.1 Standard DIN Rail mounting 1.2 Screw Mounting 2. FUSE REPLACEMENT 3. ASSEMBLING THE UNIT

More information

PBSCONTROL. AMS-R4000 Modular RTU. Remote Terminal Unit

PBSCONTROL. AMS-R4000 Modular RTU. Remote Terminal Unit PBSCONTROL AMS-R4000 Modular RTU Remote Terminal Unit AMS-R4000 Introduction The documentation and the software included with this product are copyrighted 2017 by pbscontrol Company. AMS-4000 System is

More information

xpico Wi-Fi Embedded Device Server Evaluation Kit User Guide

xpico Wi-Fi Embedded Device Server Evaluation Kit User Guide xpico Wi-Fi Embedded Device Server Evaluation Kit User Guide Part Number 900-643-R Revision B July 2013 Copyright and Trademark Warranty Contacts 2013 Lantronix, Inc. All rights reserved. No part of the

More information

DinBox M36 Hardware Description Guide

DinBox M36 Hardware Description Guide DinBox M36 Hardware Description Guide This manual covers the different hardware settings when using the DinBox M36 equipment. Next to this you will find all the relevant technical information needed when

More information

Mini Driver V (Mini Driver MP with 5-Screw Terminal Block) MINI DRIVER MP

Mini Driver V (Mini Driver MP with 5-Screw Terminal Block) MINI DRIVER MP MAY 1997 ME745A-F-R2 ME745A-M-R2 ( Driver MP with 5-Screw Terminal Block) MINI DRIVER MP CUSTOMER SUPPORT INFORMATION Order toll-free in the U.S. 24 hours, 7 A.M. Monday to midnight Friday: 877-877-BBOX

More information

ISO 9001 CERTIFIED. 607 NW 27th Ave Ocala, FL Phone: (352) or Fax: (352) SUITABLE FOR EXTERNAL DISTRIBUTION

ISO 9001 CERTIFIED. 607 NW 27th Ave Ocala, FL Phone: (352) or Fax: (352) SUITABLE FOR EXTERNAL DISTRIBUTION ISO 9001 CERTIFIED Phone: (352) 629-5020 or 800-533-3569 Fax: (352)-629-2902 ES-Key 12- Relay Board P/N 103190 and 103338 PAGE 1 of 13 1. REVISI LOG... 2 2. OVERVIEW... 3 2.1. PART NUMBERS... 3 2.2. MODULE

More information

1. CP430, CP470, CP474, CP770 and CP774

1. CP430, CP470, CP474, CP770 and CP774 1. CP430, CP470, CP474, CP770 and CP774 1.1 Order data CPUs CP430, CP470, CP474, CP770 and CP774 CP430, CP470, CP770 CP474, CP774 Model number 7CP430.60-1 7CP470.60-2 7CP474.60-2 7CP770.60-1 7CP774.60-1

More information

GT- IRDM-9603 Product description Rev. 2 17/06/2014

GT- IRDM-9603 Product description Rev. 2 17/06/2014 GT- IRDM-9603 Product description Rev. 2 17/06/2014 1 1. Overview The GT- IRDM- 9603 is a complete Satellite Terminal solution for Satellite applications. Based on IRIDIUM 9603 module. 2. Hardware Interface

More information

JetBox 9300/9310 User Manual. Hardware

JetBox 9300/9310 User Manual. Hardware JetBox 9300/9310 User Manual Hardware www.korenix.com 0.0.6 Copyright Notice Copyright 2008 Korenix Technology Co., Ltd. All rights reserved. Reproduction without permission is prohibited. Information

More information

FCC Information. RoHS This product is RoHS compliant. SJ/T The following contains information that relates to China.

FCC Information. RoHS This product is RoHS compliant. SJ/T The following contains information that relates to China. FCC Information This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection

More information

Serial Communication Converters & Adapters Instruction Manual

Serial Communication Converters & Adapters Instruction Manual Serial Communication Converters & Adapters Instruction Manual RS-232 to RS-422/485 Converter Isolated RS-232 to RS-422/485 Converter USB to RS-232 Converter USB to RS-422/485 Converter Isolated USB to

More information

Installing the DX LCD Display

Installing the DX LCD Display DX LCD Display User s Guide 3-1 Chapter 3 Installing the DX LCD Display Introduction Use the DX LCD Display as either a portable device, or permanently mount it in a panel or on the wall. For panel and

More information

Fibre Modem - Single-mode

Fibre Modem - Single-mode Revision 1.0 November. 2006 1 - Single-mode P/N: : 995087 Model 3000 / Access 4000 Optically Isolated Interface INSTALLATION GUIDE OVERVIEW: The Inner Range Single-mode provides 2 separate, optically isolated

More information

UniMod Ethernet. LAN-Modem. Bär Industrie-Elektronik GmbH Siemensstr. 3 D Fürth Germany

UniMod Ethernet. LAN-Modem. Bär Industrie-Elektronik GmbH Siemensstr. 3 D Fürth Germany LAN-Modem Operation Manual E121711217066 Bär Industrie-Elektronik GmbH Siemensstr. 3 D-90766 Fürth Germany Phone: +49 (0)911 970590 Fax: +49 (0)911 9705950 Internet: www.baer-gmbh.com COPYRIGHT Copyright

More information

DIN Rail Mounted Dial-up Modem Users Manual

DIN Rail Mounted Dial-up Modem Users Manual DIN Rail Mounted Dial-up Modem Users Manual 366-100 Copyright 2002 Miille Applied Research Co., Inc. Houston, Texas Page 1 This page is left blank intentionally Page 2 Page 1 TABLE OF CONTENTS 1.1 General...

More information

485DRCI. Industrial RS-232 to RS-422/485 Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

485DRCI. Industrial RS-232 to RS-422/485 Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology 485DRCI Industrial RS-232 to RS-422/485 Converter p/n 7207r5 485DRCI-2212ds page 1/5 Data Rates up to 115.2 Kbps 10 48 VDC Input Power Range Wide Operating Temperature 3-Way 2000V Optical Isolation Modbus

More information

SCB-C08 USB to RS232/422/485 Converter

SCB-C08 USB to RS232/422/485 Converter SCB-C08 USB to RS232/422/485 Converter USB Interface RS-232 signal RS-422 signal: RS-485 signal: Cable Type Transmission distance Signal LED Direct power from USB port Power consumption: Compliant with

More information

PCAN-Repeater DR CAN Repeater for the Decoupling of Bus Segments. User Manual. Document version ( )

PCAN-Repeater DR CAN Repeater for the Decoupling of Bus Segments. User Manual. Document version ( ) PCAN-Repeater DR CAN Repeater for the Decoupling of Bus Segments User Manual Document version 2.0.0 (2018-02-20) Relevant products Product Name Model Part number PCAN-Repeater DR Industry IPEH-004038 PCAN

More information

ICD200A Quick Start Guide. Convert RS-232 data signals to RS-422/485 signals in heavy industrial areas.

ICD200A Quick Start Guide. Convert RS-232 data signals to RS-422/485 signals in heavy industrial areas. Industrial Opto-Isolated RS-232 to RS-422/485 Converter Convert RS-232 data signals to RS-422/485 signals in heavy industrial areas. Rugged IP30-rated metal case for panel mounting. Quick Start Guide Customer

More information

USER MANUAL. MODEL 1018 High Speed Short Range Modem w/ Extra Controls SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL. MODEL 1018 High Speed Short Range Modem w/ Extra Controls SALES OFFICE (301) TECHNICAL SUPPORT (301) USER MANUAL MODEL 1018 High Speed Short Range Modem w/ Extra Controls Part# 07M1018-B Doc# 013021UB Revised 11/3/95 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 1.0 WARRANTY INFORMATION

More information

HomeVision-Pro Overview for HomeVision Users

HomeVision-Pro Overview for HomeVision Users HomeVision-Pro Overview for HomeVision Users This document has two main purposes: 1. To describe the main differences between HomeVision and HomeVision-Pro. 2. To assist HomeVision users in converting

More information

Q7055C Building Network Adapters BNA-1C/2CS

Q7055C Building Network Adapters BNA-1C/2CS Q0C Building Network Adapters BNA-C/CS INSTALLATION INSTRUCTIONS WARNING This equipment generates, uses and can radiate radio frequency energy, and if not installed and used in accordance with the Instructions

More information

Q7055B Building Network Adapters BNA-1C/2CS/2DN

Q7055B Building Network Adapters BNA-1C/2CS/2DN Q0B Building Network Adapters BNA-C/CS/DN INSTALLATION INSTRUCTIONS WARNING This equipment generates, uses and can radiate radio frequency energy, and if not installed and used in accordance with the Instructions

More information

EasySync Ltd. ES-R-2x01-M RS232 to RS422 / RS485 Converter. User Guide. Document Reference No.: ES_ Version draft Issue Date:

EasySync Ltd. ES-R-2x01-M RS232 to RS422 / RS485 Converter. User Guide. Document Reference No.: ES_ Version draft Issue Date: EasySync Ltd ES-R-2x01-M RS232 to RS422 / RS485 Converter User Guide Document Reference No.: ES_000011 Issue Date: 2009-04-10 The ES-R-2001-M and ES-R-2101-M provide a simple method of converting RS232

More information

EX & EX-45362IS 2S RS232/422/485 3-in-1 Serial PCIe Card

EX & EX-45362IS 2S RS232/422/485 3-in-1 Serial PCIe Card EX-45362 & EX-45362IS 2S RS232/422/485 3-in-1 Serial PCIe Card Congratulation on your purchasing this high performance 2-Port RS232/422/485 3-in-1 Serial PCIe Host Adapter. The adapter is high speed PCIe

More information

NPort S8000 Series Quick Installation Guide

NPort S8000 Series Quick Installation Guide NPort S8000 Series Quick Installation Guide Edition 6.0, March 2016 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777 Fax: 1-714-528-6778

More information

Lantech LSC-1102B SERIAL TO TCPIP CONVERTER. User Manual

Lantech LSC-1102B SERIAL TO TCPIP CONVERTER. User Manual Lantech LSC-1102B SERIAL TO TCPIP CONVERTER User Manual V1.0 Sep 2016 Table of Contents 1. Introduction 3 Overview 4 Product Specifications 8 2. Description & Installation 10 Product Panel Views 10 LED

More information

Document Name: User Manual for SC10EK4 Serial to Ethernet Converter with 4 TCP Sockets. Index

Document Name: User Manual for SC10EK4 Serial to Ethernet Converter with 4 TCP Sockets. Index Document Name: User Manual for SC10EK4 Serial to Ethernet Converter with 4 TCP Sockets. Index Technical Specifications 1 Installation Procedure 1 LED Indications 2 Configuration Procedure Configuration

More information

NPort 5400 Series Quick Installation Guide

NPort 5400 Series Quick Installation Guide NPort 5400 Series Quick Installation Guide Edition 7.0, November 2015 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777 Fax: 1-714-528-6778

More information

NMID. Remote control. SAPIM I/O number. SAPIM I/O number NBRN (RS485) ZM100. Relay, 24 VDC - + UO07 UI11 UI10 UI09 UI08 UI07 UI06 UI05 UI04 UI03 UI02

NMID. Remote control. SAPIM I/O number. SAPIM I/O number NBRN (RS485) ZM100. Relay, 24 VDC - + UO07 UI11 UI10 UI09 UI08 UI07 UI06 UI05 UI04 UI03 UI02 1/8 NRK16/A, NRK16-B/A, (NRK16-T /A, NRK14-T /A, NRK16-WEB/A) Control and interlock devices with pre-programmed system-specific application modules The controllers may be used as stand-alone control and

More information

3.1 I-7560 Pin Assignment and Specifications: Introduction

3.1 I-7560 Pin Assignment and Specifications: Introduction 3.1 I-7560 Pin Assignment and Specifications: Introduction The I-7560 adds a Windows serial Com port via its USB connection and is compatible with new & legacy RS-232 devices. USB Plug and Play allows

More information

NPort 5100 Series Quick Installation Guide

NPort 5100 Series Quick Installation Guide NPort 5100 Series Quick Installation Guide Edition 4.0, November 2015 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777 Fax: 1-714-528-6778

More information

General Operating, Maintenance and Installation Manual

General Operating, Maintenance and Installation Manual General Operating, Maintenance and Installation Manual Hardware Platform for Protocol Converter Small Embedded Controller - SEC2-91056 Erlangen Telephone +49 9131 92076-0 Fax: +49 9131 92076-10 Internet:

More information

VL BPC MINI. A configurable industrial computer platform. Data sheet 2930_en_F. 1 Description. 2 Features

VL BPC MINI. A configurable industrial computer platform. Data sheet 2930_en_F. 1 Description. 2 Features A configurable industrial computer platform Data sheet 90_en_F Description PHOENIX CONTACT 0-08- Features The VL BPC MINI is an embedded box PC and is part of the Valueline family of industrial computers.

More information

Koppelmodul (HART--Modem) für SIMATIC PDM Interface (HART modem) for SIMATIC PDM

Koppelmodul (HART--Modem) für SIMATIC PDM Interface (HART modem) for SIMATIC PDM Koppelmodul (HART--Modem) für SIMATIC PDM Interface (HART modem) for SIMATIC PDM 7MF4997--1DA Ausgabe Februar 2002 Edition February 2002 C73000--B7164--C170--2 1 /16 Koppelmodul für SIMATIC PDM Interface

More information

EasyCoder 501/601 Installation Instructions

EasyCoder 501/601 Installation Instructions RS 422/485 INTERFACE KIT Introduction Note: Illustrations show an EasyCoder 501. The principles for fitting this optional equipment in an EasyCoder 601 are exactly the same. The RS 422/485 Interface Board

More information

Bluetooth to RS-232&RS422/485. EX-9132B/BI Bluetooth Adapter Operation Manual

Bluetooth to RS-232&RS422/485. EX-9132B/BI Bluetooth Adapter Operation Manual Bluetooth to RS-232&RS422/485 EX-9132B/BI Bluetooth Adapter Operation Manual First Edition, Jun 2008 Table of Contents 1. Introduction 2 2. Package checklist 3 3. Product Specification 4 4. Product Panel

More information

8051 Intermidiate Development Board. Product Manual. Contents. 1) Overview 2) Features 3) Using the board 4) Troubleshooting and getting help

8051 Intermidiate Development Board. Product Manual. Contents. 1) Overview 2) Features 3) Using the board 4) Troubleshooting and getting help 8051 Intermidiate Development Board Product Manual Contents 1) Overview 2) Features 3) Using the board 4) Troubleshooting and getting help 1. Overview 2. Features The board is built on a high quality FR-4(1.6

More information

xpico 110 Wired Device Server Module Evaluation Kit User Guide

xpico 110 Wired Device Server Module Evaluation Kit User Guide xpico 110 Wired Device Server Module Evaluation Kit User Guide Part Number 900-788-R Revision A April 2017 Intellectual Property 2017 Lantronix, Inc. All rights reserved. No part of the contents of this

More information

CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE

CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE 13050201 (c) Copyright DIP Inc., 1996 DIP Inc. P.O. Box 9550 MORENO VALLEY, CA 92303 714-924-1730 CONTENTS DN502 PRODUCT OVERVIEW 1 DN502 INSTALLATION 1 POWER

More information

USB to RS-232/RS422/485. US-101-I USB To Serial Operation Manual

USB to RS-232/RS422/485. US-101-I USB To Serial Operation Manual USB to RS-232/RS422/485 US-101-I USB To Serial Operation Manual First Edition, Jun 2008 Table of Contents 1. Introduction 2 2. Package checklist 3 3. Product Specification 4 4. Product Panel Views Description

More information

RN-134. WiFly GSX Super Module SuRF Board. Features. Description. Applications. ~ page 1 ~ rn-134-ds v1.

RN-134. WiFly GSX Super Module SuRF Board. Features. Description. Applications. ~ page 1 ~  rn-134-ds v1. WiFly GSX Super Module SuRF Board Features UART interface with RS232 and TTL signaling Through hole board simplifies system integration Accepts 3-12VDC Status LEDs to show network status and data transfer

More information

8-Port IP40 IEEE802.3af PoE Unmanaged Industrial Switch User s Manual

8-Port IP40 IEEE802.3af PoE Unmanaged Industrial Switch User s Manual 8-Port IP40 IEEE802.3af PoE Unmanaged Industrial Switch User s Manual Version 1.1 Content Overview... 1 Introduction... 1 Features... 2 Technical Specifications... 3 Packing List... 5 Safety Precaution...

More information

RS-422/485 PCIe Card

RS-422/485 PCIe Card RS-422/485 PCIe Card User Manual Ver. 3.00 All brand names and trademarks are properties of their respective owners. Contents: Chapter 1: Introduction... 3 1.1 Product Introduction... 3 1.2 Features...

More information

Product description Rev. 3 11/06/14

Product description Rev. 3 11/06/14 EZ863-2G - GNSS Product description Rev. 3 11/06/14 1 Table of Contents 1. Overview... 4 2. General Description... 4 2.1 Dimensions... 4 2.2 Weight... 4 2.2 Installation... 5 2.3 Casing material... 6 2.4

More information

RS-422/485 PCI Card User Manual Ver All brand names and trademarks are properties of their respective owners.

RS-422/485 PCI Card User Manual Ver All brand names and trademarks are properties of their respective owners. RS-422/485 PCI Card User Manual Ver. 2.00 All brand names and trademarks are properties of their respective owners. Contents: Chapter 1: Introduction... 3 1.1 Product Introduction... 3 1.2 Features...

More information

The Single Dimmer Board

The Single Dimmer Board The Single Dimmer Board Introduction This electronic system has been designed as an interface unit between a Cronapress illuminated press strip and an external system such as a security alarm system; a

More information

MRUC-20 Modul-R CAN Bus Network

MRUC-20 Modul-R CAN Bus Network MRUC-20 Modul-R CAN Bus Network BALOGH This manual is based on information available at the time if its publication. Every effort has been made to provide accurate and up-to-date information. This document

More information

Modbus TCP/RTU Gateway

Modbus TCP/RTU Gateway Modbus TCP/RTU Gateway Hardware Installation Guide for models IE-GW-MB-2TX-1RS232/485 IE-GWT-MB-2TX-1RS232/485 Second Edition, June 2014 1516600000/01/06.14 Important note: The detailed user manual, additional

More information

Technical Documentation, RTCU-SA

Technical Documentation, RTCU-SA Technical Documentation, RTCUSA The RTCUSA product (GSM antenna not included in product) The RTCUSA product is a RTCU unit with a builtin communications module such as GSM, DECT or FSK Modem. The RTCUSA

More information

MGate 5111 Quick Installation Guide

MGate 5111 Quick Installation Guide MGate 5111 Quick Installation Guide Edition 1.0, December 2017 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777 Fax: 1-714-528-6778

More information

User manual Compact Web PLC WP240 series IEC-line. update:

User manual Compact Web PLC WP240 series IEC-line. update: User manual Compact Web PLC WP240 series IEC-line update: 16-06-2017 IEC-line by OVERDIGIT overdigit.com 1. General description The WP240 device is a PLC, programmable in IEC61131-3 language using CoDeSys

More information

Serial PROFIBUS Interface

Serial PROFIBUS Interface Installation Manual Serial PROFIBUS Interface Version: EN-062016-2.3 Copyright 2016 Softing Industrial Automation GmbH Disclaimer of liability The information contained in these instructions corresponds

More information

MGate 5118 Quick Installation Guide

MGate 5118 Quick Installation Guide MGate 5118 Quick Installation Guide Edition 1.0, December 2016 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777 Fax: 1-714-528-6778

More information

Technical Manual for RTCU M10 / M10G

Technical Manual for RTCU M10 / M10G Technical Manual for RTCU M10 / M10G Version 1.04 Introduction This manual contains technical documentation allowing easy installation and use of the RTCU M10 / M10G unit. In the following text RTCU M10

More information

Hardware Manual RM CANview

Hardware Manual RM CANview Hardware Manual RM CANview 1998-2005 RM Michaelides Software & Elektronik GmbH Donaustraße 14 D-36043 Fulda Germany cv_hw_e.doc Table of Contents 1 Legal Regulations...3 2 About the CANview...4 3 Important

More information

DATA CONNECT ENTERPRISE

DATA CONNECT ENTERPRISE DATA CONNECT ENTERPRISE User s Manual IG202T and IGV23 Modem Document Number 520-01005-001 Rev. A DATA CONNECT Contents Contents... iii Figures... iv Chapter 1 Introduction... 5 Features...6 Applications...7

More information

The ECL Apex 20 is operated by means of either a PC or the ECL Apex Web Panel. Temperature input signals are based on Pt 1000 or 0-10 V.

The ECL Apex 20 is operated by means of either a PC or the ECL Apex Web Panel. Temperature input signals are based on Pt 1000 or 0-10 V. ECL Apex 20 controller and ECA 20 (ECL Apex Web Panel) Description ECL Apex 20 and ECA 20 ECL Apex 20 The ECL Apex 20 and the ECA 20 (ECL Apex Web Panel) are used in large district heating applications.

More information

Intelligent Devices IDI 6005 Speed Sign Controller Technical Manual

Intelligent Devices IDI 6005 Speed Sign Controller Technical Manual Intelligent Devices IDI 6005 Speed Sign Controller 4411 Suwanee Dam Road, Suite 510 Suwanee, GA 30024 T: (770) 831-3370 support@intelligentdevicesinc.com Copyright 2011, Intelligent Devices, Inc. All Rights

More information

SP-7 AHRS. Firmware upgrade instructions. Installation and calibration

SP-7 AHRS. Firmware upgrade instructions. Installation and calibration SP-7 AHRS Firmware upgrade instructions Installation and calibration General This document describes the firmware upgrade procedure and new functionality of the SP-7 Firmware release. The firmware upgrade

More information