1 Chapter 3 Installing and Setting Up the Components This section of the AKC 55 manual will explain, for each network component: (1) Description and Identification (5) Network connections (2) Mounting (6) Load connections (3) Setting the component s network address (7) Power connections (4) Hardware Options (8) Inspection of the installed component Chapter 3-1 Installing an AKC 55 Controller The AKC 55 is assembled from two circuit boards: the Central Processing Unit, or CPU (which includes the display sub-assembly) and the Power Supply & Communications Board (PS/COMM). The AKC 55 is available packaged two ways: (1) as a panel-mount for OEM installation, and (2) in a box enclosure with a hinged door. Either package may be ordered with or without an LCD display. AKCESS System Manual RC.IU.B1.22 4/
2 AKC 55 with Enclosure Mounting Using the pre-drilled holes, mount the AKC 55 securely to a solid surface. Operating temperature must be in the range from 32 o F to 122 o F, and relative humidity in the range from 0% to 95% (non-condensing). Avoid mounting the unit where it could be subject to excessive vibration. akc55box.dwg 2/99 AKC 55 Addressing The AKC 55 s in a network are addressed by setting two rotary switches (shown in the following illustration) on the CPU board. There is a cut out on the lower left side of the CPU shield plate through which the switches can be set with a small screwdriver. Each AKC 55 must have a unique address. The host network must havean AKC 55 addressed 00." After the address is set or changed, power to the unit must be interrupted and restored for the new address to take effect and be stored. 3-2 System Manual RC.IU.B1.22 4/99.1 AKCESS
3 CPU Battery Enable Before the AKC 55 is put in service, make sure that the BATTERY ENABLE Berg jumper is put in the ON position. A clearly labeled opening is provided in the CPU shield so that the battery enable jumper can be moved. If the battery is not enabled, the controller will lose its configuration whenever the power is interrupted. HEY! Enable your AKC 55 battery, or you ll lose your configuration!! Modem Installation Install the modem inside the AKC 55 box, or choose a location for the modem close enough to an AKC 55 so that the 3 foot connecting power cable supplied with the modem can be used. Connect the modem to the modem data port on the PS/COMM board. Then, connect the modem power cable to the PS/ COMM board terminals labeled MODEM POWER using the power cord supplied. (A modem can be added after the initial installation, but only modems supplied by Danfoss can be used in an AKCESS system.) Telephone Line Installation For best results, the telephone line used should be a dedicated voice grade two-wire central office line. Bring the telephone cable to the modem location and terminate it to a standard RJ-11 jack. Then connect the modem to the RJ-11 jack with the modular telephone cord supplied with your modem. If a PBX line must be used, the PBX vendor should be consulted for proper wiring. Ethernet Adapter Connection There are two Danfoss ethernet adapter kits: COMM-E-120 and COMM-E-220, for 120 and 220 VAC respectively. Connect the ethernet adapter (using one of the cables in the kit) to the serial port connector on the bottom of the AKC 55 box. Then follow the instructions that accompany the adapter kit to establish commuincations. AKCESS System Manual RC.IU.B1.22 4/
4 Host Network Cabling & Termination Connect the AKC 55 using RS-485 host network cable (3-conductor stranded shielded AWG 18) at the Host Network Connection terminals on the PS/COMM board. Connect the shield to the SHIELD or GND terminal ONLY at the first AKC 55. At each controller between the first and last ones on the network, wirenut the shields together so that the shield is continuous, and insulated from ground, for the entire length of the network. Leave the shield loose at the last controller, but insulate it from ground. If there is more than one AKC 55 in the host network, make sure that the termination jumpers are set in the OFF position for all AKC 55 s in the host network except for the first and the last ones in the physical chain. Make sure the termination jumpers for the first and last AKC 55 s are set to the ON position. The drawing immediately below should make clear that the correct setting of an AKC 55 s termination jumpers does not depend on its address but rather on its physical location in the host network. Remember, set termination ON for the first and last AKC 55's, and OFF for all the rest!! 3-4 System Manual RC.IU.B1.22 4/99.1 AKCESS
5 I/O Network Cabling & Termination Up to five I/O network cables can be connected to an AKC 55 at the terminals labeled I/O Network on the PS/COMM board. There is no polarity to observe; connect the two signal wires to the terminals labeled A and B, and the cable shield to the terminal. Remember to terminate the last board or other node on each main cable run, as we showed you on page 2-2! Power Wiring Power selection jumpers are located on the PS/COMM board. The unit is shipped with the jumpers positioned for 220 VAC. Before connecting power, position the jumpers as shown in the illustration for the appropriate supply voltage. Power connection is then made to the terminals labeled POWER IN, observing the terminal labeling, where G = ground, N = neutral, and L = line. When the PS/COMM board has power, its red LED labeled POWER ON will light. AKCESS System Manual RC.IU.B1.22 4/
6 AKC 55 Installer Final Inspection When an AKC 55 is completely installed, you will see: First, the CPU side... (1) The CPU shield is in place, secured by its six nylon cap nuts. (2) The BATTERY ENABLE Berg jumper has been put in the ON position. (3) The CPU STATUS LED is lighted. (See #6 below) (4) The address is correctly set (00 for master, 01, 02, 03, etc. for other AKC 55 s). Now, look at the PS/COMM board... (5) The main power selector jumper (110 VAC-220 VAC) is correctly set. (6) Power of the correct voltage is connected to the POWER IN terminals. (7) The power LED is lighted. (8) If a system modem is to be connected to this AKC 55, the modem is connected to the modem data port by the cable furnished. Make sure that the modem has power as required. (9) The RS 485 cable to other AKC 55 s in the host network is connected and if this is the first or last AKC 55 in the host network, the termination jumper is in the ON position. (10) All I/O cables are connected, and each main I/O run is terminated using one of the terminators shipped with the AKC 55, and a terminator remains in place across each unused set of A & B network connections on the PS/COMM board. 3-6 System Manual RC.IU.B1.22 4/99.1 AKCESS
7 Installing an AKC 55 Panel Mount Mounting The AKC 55 PM should be mounted through a solid control panel in an opening 10 inches wide by 12.5" high. To provide adequate ventilation for the AKC 55, insure that a minimum depth of 6" is provided. Operating temperature must be in the range from 32 o F to 122 o F, and relative humidity in the range from 0% to 95% (non-condensing). Locations subject to excessive vibration should be avoided. AKC 55 Addressing The AKC 55 s in a network are addressed by setting the two rotary switches on the CPU board. There is a cut out on the lower left side of the CPU shield plate through which the switches can be set with a small screwdriver. Each AKC 55 must have a unique address. The host network must have an AKC 55 addressed 00. CPU Battery Enable Before the AKC 55 is put in service, make sure that the BATTERY ENABLE Berg jumper is put in the ON position. It is necessary to remove the metal CPU shield with the PS/COMM board attached, then set the jumpers as shown in the following illustration. The jumper location is indicated in the drawing with the shield and PS/COMM board attached. If the battery is not enabled, the controller will lose its configuration if there is a power failure. AKCESS System Manual RC.IU.B1.22 4/
8 HEY! Enable your AKC 55 battery, or you ll lose your configuration. Modem Installation Choose a mounting location for the modem where neither it nor the ribbon cable connecting it to the PS/ COMM board is subject to interference from high voltage devices. Mount the modem using the mounting plate provided with it. Connect the modem to the modem data port on the PS/COMM board using the furnished ribbon cable. Connect the modem power cable to the modem and to the PS/COMM board s MODEM POWER terminals. Telephone Line Installation Ethernet Adapter Connection The telephone line used should be a dedicated voice grade two-wire central office line for best results. Terminate the telephone line to an RJ-11 jack near the modem location, then connect the modem to the RJ-11 jack with the modular phone cord furnished with your modem. If a PBX line must be used, the PBX vendor should be consulted for proper wiring. There are two Danfoss ethernet adapter kits: COMM-E-120 and COMM-E-220, for 120 and 220 VAC respectively. Connect the ethernet adapter (using one of the cables in the kit) to the AKC 55 s serial port connector. Then follow the instructions that accompany the adapter kit to establish commuincations. 3-8 System Manual RC.IU.B1.22 4/99.1 AKCESS
9 Host Network Cabling & Termination Connect the AKC 55 using RS-485 host network cable (3-conductor stranded shielded AWG 18) at the Host Network Connection terminals on the PS/COMM board. Connect the shield to the SHIELD or GND terminal ONLY at the first AKC 55. At each controller between the first and last ones on the network, wirenut the shields together so that the shield is continuous, and insulated from ground, for the entire length of the network. Leave the shield loose at the last controller, but insulate it from ground. If there is more than one AKC 55 in the host network, make sure that the termination jumpers are set in the OFF position for all AKC 55 s in the host network except for the first and the last ones in the chain. Make sure the termination jumpers for the first and last AKC 55 s are set to the ON position. The drawing immediately below should make clear that the correct setting of an AKC 55 s termination jumpers does not depend on its address but rather on its physical location in the host network. Remember, set termination ON for the first and last AKC 55's, and OFF for all the rest!! AKCESS System Manual RC.IU.B1.22 4/
10 I/O Network Cabling & Termination Up to five I/O network cables can be connected to an AKC 55 at the terminals labeled I/O Network on the PS/COMM board. There is no polarity to observe; connect the two signal wires to the terminals labeled A and B, and the cable shield to the terminal labeled shield. You ve got to terminate the last board on every main I/O cable run! Power Wiring Power selection jumpers are located on the PS/COMM board. The unit is shipped with the jumpers positioned for 220 VAC. Before connecting power, position the jumpers as shown in the illustration for the appropriate supply voltage. Power connection is then made to the terminals labeled POWER IN, observing the terminal labeling, where G = ground, N = neutral, and L = line. (For VAC service, connect L1 & L2 to the POWER IN terminals labeled L & N. ) When the PS/COMM board has power, its red LED labeled POWER ON will light System Manual RC.IU.B1.22 4/99.1 AKCESS
11 AKC 55 Installer Final Inspection When an AKC 55 is completely installed, you will see: First, the CPU side... (1) The CPU shield is in place, secured by its six nylon cap nuts. (2) The BATTERY ENABLE Berg jumper has been put in the ON position. (3) The CPU STATUS LED is lighted. (See #6 beelow) (4) The address is correctly set (00 for master, 01, 02, 03, etc. for other AKC 55 s). Now, look at the PS/COMM board... (5) The main power selector jumper (110 VAC-220 VAC) is correctly set. (6) Power of the correct voltage is connected to the POWER IN terminals. (7) The power LED is lighted. (8) If this AKC 55 is address 00, and if the system includes a modem, the modem is connected to the modem data port by the cable furnished. Make sure that the modem has power as required. (9) The RS 485 cable to other AKC 55 s in the host network is connected and if this is the first or last AKC 55 in the host network, the termination jumper is in the ON position. (10) All I/O cables are connected, and each main I/O run is terminated using one of the terminators shipped with the AKC 55, and a terminator remains in place across each unused set of A & B network connections on the PS/COMM board. AKCESS System Manual RC.IU.B1.22 4/
Installing VO2 Analog Output Boards
Chapter 3-6 VO2 Description and Identification Installing VO2 Analog Output Boards The VO2 Variable Output board provides an AKC 55 system with 2 variable outputs for control of loads like variable speed
More informationMAKING MODERN LIVING POSSIBLE AK-255 CO 2. Controller On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS
MAKING MODERN LIVING POSSIBLE Controller On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS How to Use This Guide Read this Guide completely as you install and start up your new Controller.
More informationREFRIGERATION AND AIR CONDITIONING. On Site Guide AK2-SC 255
REFRIGERATION AND AIR CONDITIONING On Site Guide AK2-SC 255 How to Use This Guide Read this Guide completely as you install and start up your new AK2-SC 255 controller. The guide will give you thorough
More informationELECTRONIC CONTROLS & SENSORS. AK-SC255 Fact Sheet Version R Software Software version 02_085
ELECTRONIC CONTROLS & SENSORS AK-SC255 Fact Sheet Version R Software Software version 02_085 What s in the Box? 1x AK-SC255 (either Box or DIN rail screen-less version) What are the different part numbers?
More informationUser s Manual. ACS550-PD 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual
User s Manual ACS550-PD 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual 2 ACS550-PD 3R Irrigation Packaged Drive ACS550 Drive Manuals GENERAL MANUALS ACS550-U1 User s Manual (1 200 HP)
More informationQUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Product Overview. Raritan DANGER!
QUICK SETUP GUIDE BCM2 Series Branch Circuit Monitors Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable
More informationBCM2 Series Branch Circuit Monitors Quick Setup Guide
BCM2 Series Branch Circuit Monitors Quick Setup Guide Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable
More informationQUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Raritan DANGER!
QUICK SETUP GUIDE BCM2 Series Branch Circuit Monitors Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable
More informationInstallation Notes TII Model 341 Protector
Installation Notes TII Model 341 Protector (ATT-IS PEC 32918) for MERLIN Communications System In Range Out of Building (IROB) Station Installation By Trained Technician Only WARNING: Failure to follow
More informationEP/2 Installation Instructions
1 2 3 4 7 ENTER 0 5 6 8 9 CLEAR + - LOGIC ONE EP/2 EP/2 Installation Instructions DOC. #569011000 A 7/30/04 PRINTED IN U.S.A. Regulatory Compliance Safety This device has been tested and found to be in
More informationSPECIAL SPECIFICATION 1864 Pole Mounted Cabinet
1993 Specifications CSJ s 0924-06-221,etc. & 0924-06-223 SPECIAL SPECIFICATION 1864 Pole Mounted Cabinet 1. Description. This specification describes the minimum acceptable requirements for a weatherproof
More informationH704-42(H)(E), H704-42/1(H)(E)
POWER MONITORING INSTALLATION GUIDE H704-42(H)(E), H704-42/1(H)(E) Branch Current Monitor DANGER NOTICE Installer's Specifications General: Operating Temp. Range 0 to 60 C (32 to 140 F) (
More informationSecured Series: Hub Plus Kit Single Door Controller Package Installation Manual
Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual This package is designed to simplify the connections to our Secured Series Hub Plus Controller. This will translate into
More informationTCNM-ACBB1 Installation Manual
The TCNM-ACBB1 is a connection box that can be used as an accessory to facilitate system connections for installation and device replacement of several Banner family reading devices. System cabling is
More informationPACSystems RX7i IC698CHS009/119
January 2010 The RX7i rack can be used for all RX7i CPU and I/O configurations, Series 90-70 I/O, and VME modules. Backplane connectors are spaced on 0.8" (20.3mm) centers to accommodate single-width RX7i
More informationThis Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount.
This Datasheet for the IC697CHS790 Rack, 9 Slots, Rear Mount. http://www.cimtecautomation.com/parts/p-14771-ic697chs790.aspx Provides the wiring diagrams and installation guidelines for this GE Series
More informationUSER MANUAL MODEL 2017P MODEL 2017P60. RS-232 to 20mA and. RS-232 to 60mA Current Loop Converters
USER MANUAL MODEL 2017P RS-232 to 20mA and MODEL 2017P60 RS-232 to 60mA Current Loop Converters 07M2017P-E Doc# 073051UE Revised 5/7/96 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 1.0
More informationPLC Racks IC697CHS782/783
5 1 PLC Racks IC697CHS782/783 (IC697CHS782/783) datasheet Features Accepts 3rd Party VME modules which require 0.8 spacing. Accepts all IC697 PLC module types. Rear mount rack mounts in a 10 (254 mm) deep
More informationCU-8R Installation Instructions
CU-8R Installation Instructions I. Components Model CU-8R is shipped with the following components: QTY Item 1 Stainless Steel Enclosure 2 Lexan Panels 18 Nuts 1 Wall Mount Style Phone with RJ-11 Cable
More informationAllen-Bradley PLCs. 100 Programmable Controller Processor Unit -Catalog Nos LPI01, -LP102, -LP103, -LP104 SLC TM. The Unit
PRODUCT DATA SLC TM 100 Programmable Controller Processor Unit -Catalog Nos. 1745-LPI01, -LP102, -LP103, -LP104 The SLC 100 programmab/e Contro"er The SLC 100 Programmable Controller is easy to program,
More informationSPECIAL INSTRUCTIONS FOR CAPACITORS COMPACT GENERATORS
SPECIAL INSTRUCTIONS FOR CAPACITORS COMPACT GENERATORS (WITH CAPACITOR CHARGER BOARD A3517-02) The process depends on Generator and System configuration. This document applies to installation of Capacitors
More informationUniStream CPU-for-Panel
UniStream CPU-for-Panel Installation Guide USC-P-B10 Unitronics UniStream platform comprises control devices that provide robust, flexible solutions for industrial automation. This guide provides basic
More informationSTATE OF NEW JERSEY BUREAUS OF ITS ENGINEERING AND SAFETY & DATA DEVELOPMENT DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625
September 2011 STATE OF NEW JERSEY BUREAUS OF ITS ENGINEERING AND SAFETY & DATA DEVELOPMENT DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625 MATERIAL SPECIFICATIONS FOR WEIGH-IN-MOTION SYSTEM The
More informationDLA. DMX512 Analyzer. DLA Users Manual SV2_00 B.lwp copyright ELM Video Technology, Inc.
DLA DMX512 Analyzer DLA DLA-HH 1 Table Of Contents IMPORTANT SAFEGUARDS... 2 DLA OVERVIEW... 3 CONNECTION... 3 OPERATION... 3 HARDWARE SETUP... 4 DLA-HH (PORTABLE) LAYOUT... 4 CHASSIS LAYOUT... 4 DLA MENU
More informationHardened 10/100Base-TX IEEE802.3at PoE PSE Ethernet Extender
Quick Start Guide This quick start guide describes how to install and use the Hardened Ethernet Extender. This is the Hardened Ethernet Extender of choice for harsh environments constrained by space. Physical
More informationRMB Peripheral Units Installation Guide
RMB Peripheral Units Installation Guide Part Number 65-000101 2011 by Kentrox, Inc. All rights reserved. Copyright 2011 by Kentrox, Inc. All Rights Reserved. The material discussed in this publication
More informationUSP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10
UniStream HMI Panel Installation Guide USP-070-B10, USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10 Unitronics UniStream platform comprises control devices that provide robust, flexible solutions for
More informationSuperBus 2000 Phone Interface/Voice Module Installation Instructions
SuperBus 2000 Module Installation Instructions Product summary The SuperBus 2000 (PIV) Module provides phone and voice functions for the Concord, Concord 4, and Concord Express (v4) panels. The PIV module
More informationInstruction Manual. Electrical Management System (EMS) EMS-HW30C & EMS-HW50C
Instruction Manual Electrical Management System (EMS) EMS-HW30C & EMS-HW50C EMS-HW50C EMS-HW30C! CAUTION These instructions are intended to provide assistance with the installation of this product, and
More informationBA/BS4S Temperature Sensor Installation & Operating Instructions
Product Overview and Identification The BAPI-Stat 4 room temperature sensor features a large format LCD and slider setpoint adjustment. Additional options include button override and communication jack.
More information1993 Specifications CSJ SPECIAL SPECIFICATION ITEM Transportation Management Console
1993 Specifications CSJ 0598-01-057 1.0 Description SPECIAL SPECIFICATION ITEM 6398 Transportation Management Console This Item shall govern for the furnishing and installation of Transportation Management
More information1993 SPECIFICATIONS CSJ , ETC. & SPECIAL SPECIFICATION ITEM 6132 ARTERIAL TRAFFIC MANAGEMENT SYSTEM
1993 SPECIFICATIONS CSJ 1685-05-068, ETC. & 1685-02-042 1.0 DESCRIPTION SPECIAL SPECIFICATION ITEM 6132 ARTERIAL TRAFFIC MANAGEMENT SYSTEM THIS ITEM DESCRIBES THE OPERATION AND INSTALLATION OF AN ARTERIAL
More informationICS Entrance Management Sign Installation Guide. Version 1.0
ICS Entrance Management Sign Installation Guide Version 1.0 Thank you for purchasing your new ICS Entrance Management System (EMS) from Innovative Control Systems, Inc. Installation Overview This document
More informationTHROWMASTER 409 T-1 System Transfer Set
THROWMASTER 409 T-1 System Transfer Set The Throwmaster Model 409 is a revolutionary new way of transferring T-1 circuits from one transmission system to another, There can be any number of repeaters or
More informationModbus Header Temperature Sensor Kits: Standard Voltage Low Voltage
Technical Instruction Document Modbus Header Temperature Kits: 24444-1 Standard Voltage 24444-3 Low Voltage Disclaimer The information contained in this manual is subject to change without notice from
More informationInstalling the DX LCD Display
DX LCD Display User s Guide 3-1 Chapter 3 Installing the DX LCD Display Introduction Use the DX LCD Display as either a portable device, or permanently mount it in a panel or on the wall. For panel and
More informationINSTALLATION INSTRUCTIONS
LIGHTING CONTROL PANELS 16 AND 24 RELAYS INSTALLATION INSTRUCTIONS INSTALLATION OVERVIEW The installation instructions contained in this document are provided as a guide for proper and reliable installation.
More informationUSBCNC USB Disk Key reader for CNC Controls Machine Mount instructions
USBCNC USB Disk Key reader for CNC Controls Machine Mount instructions 2008-2015 Calmotion LLC, All rights reserved Calmotion LLC 21720 Marilla St. Chatsworth, CA 91311 www.calmotion.com Introduction This
More informationTemperature. Power requirements. Weight. Dimensions
Installing the Tracer Summit BMTX Building Control Unit Ordering numbers: BMTX001AAB000, BMTX001AAB010, BMTX001AAB001, BMTX001AAB011, BMTX001BAB000, BMTX001BAB010, BMTX001BAB001, BMTX001BAB011, BMTX001DAB000
More informationPanelView Plus/VersaView CE Terminals and Display Modules
Installation Instructions PanelView Plus/VersaView CE Terminals and Display Modules (Catalog Numbers 2711P-xxxxxx, 6182H-xxxxxx) English Inside: Overview...2 For More Information...2 Modular Components...3
More informationHypercable injecteur HPOE - Industrial IEEE 802.3at Gigabit PoE Injector. User Manual. v.1.0 Jun Mail :
Industrial IEEE 802.3at Gigabit PoE Injector User Manual v.1.0 Jun-2011 FCC Warning This Equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15
More informationTraceTek Leak Detection Master Module Installation Instructions TOOLS REQUIRED STORAGE
TTDM-128 TraceTek Leak Detection Master Module Installation Instructions TRACETEK APPROVALS AND CERTIFICATIONS TYPE NM General Signaling Equipment 76LJ GENERAL INFORMATION Please read these instructions
More informationDraper Low Voltage, Remote Control, Serial and Network Wiring Guide
Draper Low Voltage, Remote Control, Serial and Network Wiring Guide Copyright 2007 Draper Inc. Form LV-RC-Serial-Network_Wiring07 Print ed in U.S.A. Draper Low Voltage, Remote Control, Serial and Network
More informationEMS. Electrical Management System. Progressive Industries Incorporated Morrisville, North Carolina
Progressive Industries Warranty Progressive warrants its products are free from defects in materials and workmanship for a period of three years. This is in lieu of all other warranties, obligations, or
More informationTECHKNOW, INC. Kiosk Order Confirmation System INSTALLATION MANUAL. Revision Date: July 11, 2012 Part # Version 3.2
document Page 1 of 18 TECHKNOW, INC Kiosk Order Confirmation System INSTALLATION MANUAL Revision Date: July 11, 2012 Part # Version 3.2 Techknow, Inc. 393 Mayfield Road Duncan, SC 29334 www.gotechknow.com
More informationModular Connectors 75
75 Plug/Jack Compliant to Enhanced Category 5 standards Connector type Size Series Name Page plug connectors compliant to enhanced category 5 standards 8 TM21P 77 jack connectors for high-speed LAN transmission
More informationPowerLogic High Density Metering System 1-Meter Enclosure
PowerLogic High Density Metering System 1-Meter Enclosure Installation Guide 63230-508-211A1 Safety information PowerLogic High Density Metering System 1-Meter Enclosure Important information Read these
More informationItem E2CD-C1C3A E2CD-C1R5C3A E2CD-X2R5C3A E2CD-X5C3A 12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.
Sensing distance 1.0 mm 1.5 mm 2.5 mm 5.0 mm High-precision Proximity Sensor Supply voltage 12 to 24 VDC Output 100 ma max., 2 outputs Ideal for Positioning and Discriminating Objects Assures minimal temperature
More informationUniStream HMI Panel. CPU-for-Panel
UniStream HMI Panel Installation Guide USP-070-B10,USP-104-B10, USP-156-B10 Unitronics UniStream platform comprises control devices that provide robust, flexible solutions for industrial automation. This
More informationDMC2. Installation Guide Version 1.0. Area for main photograph. Area for insert photo. W: 46.1mm up to 79 mm H: 46.1mm
Area for main photograph Area for insert photo W: 46.1mm up to 79 mm H: 46.1mm X: 12.6mm absolute on page Y: 132.6mm abs on page This insert has a shadow DMC2 Installation Guide Version 1.0 Contents DMC2
More informationInstalling And Programming The Off-Premise Extension Interface On The Digital Communications System
R Installing And Programming The Off-Premise Extension Interface On The Digital Communications System 1.0 Introducing The Off-Premise Extension Interface This publication describes the features, applications,
More informationEthernet Adapter Installation Instructions
Ethernet Adapter Installation Instructions DOC. #569040000 A 7/30/04 PRINTED IN U.S.A. Disclaimer Logic One is a registered trademark of Novar Controls Corporation. The material in this manual is for information
More informationPower Input Assignment Power1 12VDC DC Jack VDC Power2 - Power Ground
Quick Start Guide This quick start guide describes how to install and use the Hardened Ethernet Extender. This is the Hardened Ethernet Extender of choice for harsh environments constrained by space. Physical
More informationMS-7000: SuperStar Reader
The MS-7000 SuperStar Reader The MS-7000 SuperStar Reader is intended for installation in proximity applications where an extended read range is required. The reader provides an audio beeper and a multi
More informationInstalling And Programming The Analog Terminal Interface On The DXP, DXP Plus, and FX Series Digital Communications Systems
R Installing And Programming The Analog Terminal Interface On The DXP, DXP Plus, and FX Series Digital Communications Systems The Analog Terminal Interface The ATI-D-1PT is a multipurpose, on-premise accessory
More informationElectrical Management System (EMS) EMS-HW30C & EMS-HW50C
Electrical Management System (EMS) EMS-HW30C & EMS-HW50C Installation & Operating Guide for: Model EMS-HW30C Rated at 120V/30A and Model EMS-HW50C Rated at 240V/50A Surgio Says Lifetime Warranty on all
More informationCopy Machine Reader. Installation and Setup Guide
Copy Machine Reader Installation and Setup Guide CONTENTS 1 COPY MACHINE READER INSTALLATION 1 Overview 1 Reader Specifications 3 CR1120/CR1122 INSTALLATION 3 Copier Interface 3 AC Electrical 3 Communications
More informationSPOS (Station Point of Sale) 200. SFTP (Station Fare Transaction Processor) 35. CQD (Card Query Device) 35. HCR (Handheld Card Reader) Cradles 120
DESIGN GUIDELINES PRESTO INSTALLATION & CONNECTIVITY PAGE 1 of 4 ELECTRICAL CONNECTIVITY AND WIRING Communications Conduits Conduits designated for Presto equipment data wiring shall be clearly identified
More informationThis guide provides basic information for Unitronics Models 230/260/280/290 (Non-color Screens).
Vision OPLC Installation Guide Models 230/260/280/290 (Non-color Screens) This guide provides basic information for Unitronics Models 230/260/280/290 (Non-color Screens). General Description Vision OPLCs
More informationEX-RC1 Remote I/O Adapter
EX-RC1 Remote I/O Adapter The EX-RC1 interfaces between Unitronics Vision OPLCs and remote I/O Expansion Modules distributed throughout your system. The adapter is connected to a PLC via CANbus. Each adapter
More informationPS-4100 POWER SUPPLY MANUAL
PS-4100 POWER SUPPLY MANUAL Manual Part Number 180-0573 December 7, 2006 TABLE OF CONTENTS TITLE PAGE Table of Contents... 2 List Of Figures... 3 1. Introduction... 4 1.0. General... 4 1.1. Features...
More informationEA500. Installation Instructions Transponder
EA500 EN Installation Instructions Transponder EA500 Installation Instructions 1.0 Overview EN 2 1.0 Overview The EA500 Transponder is the Security Escort module that provides communications between the
More informationWTI-3101 Dialog Telephone Interface. User Manual
WTI-3101 Dialog Telephone Interface User Manual Douglas Lighting Controls Page 1 February 5, 2014 Contents Introduction... 3 Specifications... 4 Operation... 4 WTI-3101 Quick Start Guide... 5 Telephone
More informationABM International, Inc. Lightning Stitch Checklist 9/13/2013
ABM International, Inc. Lightning Stitch Checklist 9/13/2013 1) Piggy backed board assembly (1) Piggy back board assembly tested? Yes No 24v passed XB passed XA passed YB passed YA passed SAFE passed S/S
More informationLANCNC FTP Data Server for CNC Controls Machine Mount instructions
LANCNC FTP Data Server for CNC Controls Machine Mount instructions 2008-2016 Calmotion LLC, All rights reserved Calmotion LLC 21720 Marilla Street Chatsworth, CA 91311 www.calmotion.com Introduction This
More informationSPECIAL SPECIFICATION 6322 Digital Video Encoder/Decoder (Ethernet) System
2004 Specifications CSJ 0902-48-433 SPECIAL SPECIFICATION 6322 Digital Video Encoder/Decoder (Ethernet) System 1. Description. Furnish and install Digital Video Encoder/Decoder (Ethernet) System (DVE/DES)
More informationWhen any of the following symbols appear, read the associated information carefully. Symbol Meaning Description
Uni-I/O Modules Installation Guide UIS-04PTN Uni-I/O is a family of Input/Output modules that are compatible with the UniStream control platform. This guide provides basic installation information for
More informationTB21. NO - Relay. Relay. Common - Relay. NC - Relay. Input J23. Ground TB22 TB23. NO - Relay Common - Relay NC - Relay Input Ground.
NXT x.0 Wiring and Layout Diagrams. NXT-x I/O Module Shielded CAT- Cabling Shielded -Conductor Cabling total cable length 00 feet max (0 m) Brown/Green/Orange w/o Stripe Brown/Green/Orange with Stripe
More informationMS-5000: MiniStar Reader
The MS-5000 MiniStar Reader The MS-5000 MiniStar Reader is intended for installation in a single gang electrical "J-Box," in proximity applications where an unobtrusive reader is required. It can also
More informationTorque Series LCD Remote Panel Installation/Operation Manual Model: TQ-DSP-12/24
Torque Series LCD Remote Panel Installation/Operation Manual Model: TQ-DSP-12/24 Section Page Introduction 1 Materials Provided 1 I) Safety Instructions 1 A) Inverter Safety Instructions 1 B) Battery Safety
More informationInstalling the Cisco AS5400XM Universal Gateway
CHAPTER 3 Installing the Cisco AS5400XM Universal Gateway This chapter guides you through the installation of the Cisco AS5400XM universal gateway and includes the following sections: Setting Up the Chassis,
More informationEX-RC1 Remote I/O Adapter
EX-RC1 Remote I/O Adapter The EX-RC1 interfaces between Unitronics Vision OPLCs and remote I/O Expansion Modules distributed throughout your system. The adapter is connected to a PLC via CANbus. Each adapter
More informationInstallation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.
Vision OPLC Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V290-19-C30B and V290-19-T40B. General Description Vision OPLCs are programmable
More informationPreparing to Install the VG248
CHAPTER 2 To ensure normal system operation, plan your site configuration and prepare your site before installation. Before installing the VG248, review these sections: Preparing the Installation Site,
More informationHUBBELL SPIKESHIELD Wired-In Branch Panels Surge Protective Device (SPD)
HUBBELL SPIKESHIELD Wired-In Branch Panels Surge Protective Device (SPD) Instruction Bulletin 8222-0513B Retain for future use. SPIKESHIELD Wired-In Branch Panels 8222-0513B 05/2012 Table of Contents Precautions...
More informationTELEPHONE/MODULAR JACK CONNECTORS
System Technical Specifications Board Mount Telephone Modular Jacks Telephone Modular Plugs ~ ~ Phone Jack 30 30 ~ 80 355 04 Series Board Mount Telephone Jacks Available in 4 and 6 ways Insulator: Gray,
More informationSPECIAL SPECIFICATION 1252 System Control Unit Console
1993 Specifications CSJ 0924-06-147, etc. SPECIAL SPECIFICATION 1252 System Control Unit Console 1. Description. This Item shall govern for the furnishing and installation of system control unit (SCU)
More informationModel 7416LED
INSTALLATION INSTRUCTIONS FOR Model 7416LED www.sportablescoreboards.com 1 Table of Contents DESCRIPTION... 3 THE SCOREBOARD SYSTEM SHOULD INCLUDE THE FOLLOWING PARTS:... 3 INSTRUCTIONS FOR REPORTING SHIPPING
More informationMODEL Weatherproofing Instructions
MODEL 1024-00 Weatherproofing Instructions Body Mount Antenna Figure 1 Oberon s 34-BMANT24 and BMANT5 (Figure 1) outdoor body mount antennas can be mounted directly to the Model 1024 enclosure. There are
More informationFLEX Ex Spring Clamp Terminal Base
Installation Instructions FLEX Ex Spring Clamp Terminal Base (Cat. No. 1797-TB3S) 1 10 11 4 Only remove this cover plug if connecting another terminal base unit. 3 5 6 12 2 7 8 9 41253 Component Identification
More informationUser s Manual. ACS550-PD Stock 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual
User s Manual ACS550-PD Stock 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual 2 ACS550-PD 3R Irrigation Packaged Drive ACS550 Drive Manuals GENERAL MANUALS ACS550-U1 User s Manual (1
More informationWhen any of the following symbols appear, read the associated information carefully. Symbol Meaning Description
Uni-I/O Modules Installation Guide UIA-0402N Uni-I/O is a family of Input/Output modules that are compatible with the UniStream control platform. This guide provides basic installation information for
More informationPGR-4700 MANUAL SENSITIVE GROUND-FAULT RELAY
Tel: +1-800-832-3873 E-mail: techline@littelfuse.com www.littelfuse.com/pgr-4700 PGR-4700 MANUAL SENSITIVE GROUND-FAULT RELAY REVISION 2-B-032218 Copyright 2018 by Littelfuse, Inc. All rights reserved.
More information4 10/100/1000T Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch. User Manual SISTP LRT
4 10/100/1000T + 2 1000 Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch User Manual V1.0 September-2013 FCC Warning This Equipment has been tested and found to comply with
More informationInstallation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.
Vision OPLC Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V290-19-C30B and V290-19-T40B. General Description Vision OPLCs are programmable
More informationHIGH PERFORMANCE TRANSISTOR INVERTER TRUE TORQUE CONTROL SERIES
HIGH PERFORMANCE TRANSISTOR INVERTER TRUE TORQUE CONTROL SERIES 12-BIT BINARY OPTION MANUAL January, 1996 Introduction Thank you for purchasing the 12-bit binary option kit for the Toshiba TOSVERT-130
More informationModels beginning with 2M, 2L or 2X. Product Description. Technical Specifications. Installation Instructions. Series 2000 Multiple Meter Units (MMUs)
Models beginning with 2M, 2L or 2X Series 2000 Multiple Meter Units (MMUs) Product Description Technical Specifications Installation Instructions February 28 th, 2013 List of Figures...2 List of Tables...2
More informationWhen any of the following symbols appear, read the associated information carefully. Symbol Meaning Description
Uni-I/O Wide Modules Installation Guide UIS-WCB1 Uni-I/O Wide is a family of Input/Output modules that are compatible with the UniStream control platform. Wide Modules are 1.5 times as wide as Uni-I/O
More informationMS-3000 MicroStar Reader
MicroStar Reader The MicroStar Reader The MicroStar Reader is intended for installation on a window mullion or a door frame, on or off metal, in proximity applications where an unobtrusive reader is required.
More informationQuick Start Installation Guide
apc/l Quick Start Installation Guide Version A2 Document Part Number UM-201 May 2010 OVERVIEW The apc/l is an intelligent access control and alarm monitoring control panel which serves as a basic building
More informationPXL-250 Tiger Controller
PXL-0 Tiger Controller This quick start guide is made up of specification sheets, a DO/DON T list, basic installation drawings, first time power-on instructions, and short descriptions of key terms and
More informationDigital Lighting Systems, Inc. PD216. Two Channel Dimmer and Switch Packs PROTOCOL USER'S MANUAL. PD216-UM Rev. E - 02/03
Digital Lighting Systems, Inc. PD26 Two Channel Dimmer and Switch Packs PROTOCOL PD26 S2 S USER'S MANUAL PD26-UM Rev. E - 02/03 Digital Lighting Systems PD26 User's Manual - Page GENERAL DESCRIPTION The
More informationSystem User Manual. AKC 55 Rack Controller
System User Manual AKC 55 Rack Controller This User s Manual contains installation, start-up, and operating instructions for all parts of the Danfoss AKCESS System. Use the Table of Contents to find the
More informationHP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions
HP UPS R/T3000 G2 Installation Instructions Overview The HP UPS R/T3000 G2 features a 2U rack-mount with convertible tower design and offers power protection for loads up to a maximum of 3300 VA/3000 W
More informationQuick Draw Electronics. Shooting Sports Timer User Manual. Model AIO-1
Quick Draw Electronics Shooting Sports Timer User Manual Model AIO-1 Rev. C October 2017 QUICKDRAW ELECTRONICS SHOOTING SPORT TIMER SYSTEM THE SYSTEM CONSISTS OF; 1 IMPACT SENSOR 1 LIGHT ASSEMBLY 1 ALL
More informationChapter 2. Installing the Chapter 2. Contents
Contents Chapter 2 Installing the 3512 Overview... 2-2 Unpacking... 2-2 Telephone Equipment... 2-3 Customer-Provided Telephone Equipment... 2-3 Telephone Company Procedures and Regulatory Requirements...
More informationEX-RC1 Remote I/O Adapter
EX-RC1 Remote I/O Adapter The EX-RC1 interfaces between Unitronics Vision OPLCs and remote I/O Expansion Modules distributed throughout your system. The adapter is connected to a PLC via CANbus. Each adapter
More informationPM Series Power Meter
PM Series Power Meter Quick Setup Guide - PMC-1000, PMC- 1001, PMM-1000, PMB-1960 Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See
More informationWhen any of the following symbols appear, read the associated information carefully. Symbol Meaning Description
Uni-I/O Modules Installation Guide UID-0808THS Uni-I/O is a family of Input/Output modules that are compatible with the UniStream control platform. This guide provides basic installation information for
More informationANC Series RS-422 Serial Communications Adapter
Rev. B $ 5.00 ANC - 6000 Series RS-422 Serial Communications Adapter Antona Corporation, Los Angeles, CA Antona Corporation (818)783-4299 FAX (818)783-4216 1 Antona Corporation Copyright Copyright (c)
More information