ESS-2000 with Discharge gun TC-815P

Size: px
Start display at page:

Download "ESS-2000 with Discharge gun TC-815P"

Transcription

1 Established 1981 Advanced Test Equipment Rentals ATEC (2832) ELECTROSTATIC DISCHARGE SIMULATOR ESS-2000 with Discharge gun TC-815P CONFORMING TO IEC R TC-815P ESS-2000 (Gun stand in the photo is an optional accessory Model: PS-806.) GENERAL Among the causes of equipment malfunction, problems caused by ESD (electrostatic discharge) are the most difficult events against which to incorporate protective measures, since the causal relation generally cannot be found easily. Air discharge testing, which is affected by numerous variable factors, is a widely adopted test method, since the actual ESD events in the field are air discharges. On the other hand, contact discharges are preferably applied since the following two benefits are obtained: high repeatability and evaluation of ESD susceptibility in terms of discharge voltage. In the contact discharge method, the very fast but stable rise time of discharge current does not vary with charge voltage prior to discharge and the waveforms are proportional to charge voltages, which allows the engineer to define the ESD susceptibility of the equipment under test in terms of charge voltage. This simulator is designed to conduct both contact and air discharge testing. FEATURES 1. This simulator meets and far exceeds the testing requirements in the IEC , generating discharges up to 30kV. In addition, various waveforms can be generated by changing the energy storage capacitor and discharge resistor. 2. Since the energy storage capacitor, discharge resistor and discharge relay are incorporated in the gun, ESS-2000 is capable of generating current with a stable rise independent of applied voltage, making it possible to conduct a reproducible test. 3. This simulator provides four operation modes, allowing the operator to conduct a single step testing for the IEC specified test voltages and for a series of stored test settings. 4. Controllable from an external computer using various communication interfaces.

2 SPECIFICATIONS Output voltage: kV ±5% Polarity: Positive or negative Charging resistance: 53 M (for combination with TC-815P discharge gun) Discharge mode: Air discharge and contact discharge Operation mode: IEC severity level Level setting 1, 2, 3, 4 Discharge interval s Manual Discharge interval s Setting storage function Up to 10 conditions storable Sweep Starting voltage ± kV Ending voltage ± kV Step voltage kV Discharge interval S Setting storage function Up to 10 conditions storable Program Voltage setting ± kV Discharge interval s No. of steps 30 steps maximum No. of programs Up to 50 conditions storable No. of program units Up to 100 conditions can be set. Temp. and humidity measurement: Current values are displayed Display element: LCD with back light Character display: English or Japanese Setting method : Ten-key pad, Rotary control, Function keys Auxiliary function: Upper limit voltage setting function Trigger switch select function Auto stop function Inversion on the screen function Clock function: Year, month, day, hour, minute (Battery backup) Memory function: Clock work, contents of each setting and last operation display are backed up for more than 3 months with battery full charged. External interface functions: GP-IB connecting I/F Warning light connecting I/F External trigger input I/F Elimination probe connecting I/F Printer I/F: Conforming to simple CENTRONIX I/F Contents of print: Currently applied voltage/ Current date/ Current temp. and humidity Contents of various settings Power supply: / V AC 50/60 Hz Operating temperature and humidity: 0 40 C 20 70% (No dewing shall occur.) Dimensions and weight: ESS (W) X 324(H) X 320(D) Approx. 8.0 kg TC-815P 75(W) X 220(H) X 255 (D) Approx. 0.9 kg (Except a cable)

3 MENU DISPLAY MODE DATE TIME 12:34:56 1 IEC SEVERITY MODE 2 MANUAL MODE 3 SWEEP MODE 4 PROGRAM MODE 0 UTILITY % DISPLAY EXAMPLE After pressing the main switch, press the mode button. This places the simulator in the initial menu, which displays the four operational modes and utility mode. The optional temperature/humidity sensor shows the current measured values. MANUAL MODE MANUAL kv DISCHARGES 1 0 INTERVAL sec START START FIX #SET SWEEP MODE SWEEP PROGRAM MODE PROG PROGRAM RAM 0 0 (+ : ADD, : CANCEL) Program No. Program unit No kv DISCHARGES 10 INTERVAL 1.00 sec START EDIT kv kv STEP DISCHARGES 1 0 INTERVAL sec START FIX #SET #SET If you desire to operate the unit in the manual mode, press the corresponding ten-key, 2. Items to be set by the operator will appear. Discharge method (contact/air discharge), discharge voltage, number of discharges and interval can be set. The item in the cursor can be varied by using the ten-key or rotary knob. Contact discharges: For contact discharge testing, after completion of required settings, press the START button and pull the trigger. The simulator will then generate the required number of pulses at the required interval. Pulling the trigger again will pause the unit. Pulling again will restart the unit. Air discharges: For air discharge testing, after completion of setting, press the START key. To carry out air discharges, keep pulling the trigger and approach the discharge tip to the EUT. Keep pulling the trigger to maintain the HV relay in the on status. In this mode, the simulator generates discharges in an automatic ramp. Starting, ending and step voltages can be freely set. In this mode, the number of discharges set is that in each step. For example, when the simulator is set to 5kV for start voltage. 10kV for end voltage, 1kV for step voltage, in a way of 10 discharges at an interval of 1 second, it produces 10 pulses at 5kV at an interval of 1 second and proceeds to 6kV pulses, also 10 discharges. These steps continue until the simulator has completed 10 pulses of 10kV. Two different ways of pulling the trigger: When the trigger is pulled and then released quickly, the simulator operates in a way that it pauses before it proceeds to next step voltage. For continuous operation, pull the trigger for more than 2 seconds. The message of CONTINUOUS is indicated on the upper right side of the screen. Test settings can be stored for 100 program units. Any combination of units selected from those 100 units can consist of one test sequence, the longest is up to 30 units. Here we call one test sequence a program. 50 programs can be stored. For program unit setting, press EDIT button. Settings of voltage, etc. can be done in the same way as the other operation modes. The trigger functions in the same ways as in the sweep mode. When pulled once and released instantly, the simulator operation pauses before it goes to the next program unit. If pulled for than 2 seconds, the simulator operates continuously.

4 STANDARD ACCESSORIES Discharge gun Model: TC-815P Discharge electrode Model: A and A Capacitor unit Model: A (150pF) AC cord Discharge resistor (330 ) Instruction manual Accessory bag CONTROLS, INDICATORS AND TERMINALS LCD indicator Stop key F1 key, F2 key Function key Receive window for a remote controller and temt/humidity sensor Cursor key Start key STOP OUTPUT START F1 F2 CONTRAST WARNING HIGH-VOLTAGE ELECTROSTATIC ESS-2000 DISCHARE SIMULATOR - T MODE Polarity key (Used to select menu voltage polarity.) Mode key (Used to display menu screen.) Ten key (Used to select menu and input numerical value.) Rotary control (Used to increase and reduce and select numerical value.) Contrast control (Used to adjust light and shade of picture.) High voltage (Used to connect discharge gun) Warning lamp Printer Warning lamp PRINTER AUX WARNING LIGHT External GP-IB GP-IB RISK WARNING OF ELECTRIC SHOCK DO NOT OPEN LINE INPUT LINE VOLTAGE RANGE 100~240V ~ 50/60Hz 91VA MAX z POWER LINE INPUT Power switch AC inlet Earth terminal

5 Options for ESS-2000 OPTIONS Tem./humidity sensor Automatic ESD eliminator Wireless remote controller Model: A Model: A Model: B Gun Holder Model: A The gun holder can be screwed to the left-side panel of the ESS Printer Model: A Printer cable Model: A Options for TC-815P *) Included accessories for TC-815P Free arm gun stand Capacitor unit Model: B 100pF: Model A Dimensions: (W)18x(H)76x(D)7cm 150pF: Model A* Weight: Approx.5kg 200pF: Model A 250pF: Model A Gun stand 300pF: Model A Model:PS pF: Model A Dimensions:(H)30cm (Diameter)16cm 400pF: Model A Weight: Approx. 1.6kg 500pF: Model A Discharge resistor 100,150,200,250,300,330*, 400,500, 1k, 1.5k, 2k, 5k, 10k Discharge electrode Model: A* Model: A* Fast rise time adapter Model: A Noise Laboratory Co., Ltd Chiyoda, Sagamihara, Kanagawa Tel: +81 (0) Fax: +81 (0)

Total Coordinator for EMC 00% 90% 30ns. 60ns 10% 30ns ELECTROSTATIC DISCHARGE H SIMULATOR. NOISE LABORATORY CO., LTD.

Total Coordinator for EMC 00% 90% 30ns. 60ns 10% 30ns ELECTROSTATIC DISCHARGE H SIMULATOR.   NOISE LABORATORY CO., LTD. Total Coordinator for EMC I 00% 90% 30ns I1 60ns 10% 30ns ESS S-2000 ELECTROSTATIC DISCHARGE H SIMULATOR M www.noiseken.com Rc Rd Cs ESS-2001 NOISE LABORATORY CO., LTD. Your products may have passed the

More information

Advanced Test Equipment Rentals ATEC (2832)

Advanced Test Equipment Rentals ATEC (2832) Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) Your products may have passed the test standards, but can they survive in the real world? There are many ESD standards

More information

Introduction. Aspects of System Level ESD Testing. Test Environment. System Level ESD Testing Part II: The Test Setup

Introduction. Aspects of System Level ESD Testing. Test Environment. System Level ESD Testing Part II: The Test Setup System Level ESD Testing Part II: The Test Setup Introduction This is the second in a series of articles on system level ESD testing. In the first article the current waveform for system level ESD testing

More information

Surge Current Generators PG **-****

Surge Current Generators PG **-**** Surge Current Generators PG **-**** Waveform 8/20 µs Surge current: 40 ka - 100 ka The surge current generators PG **-*** generate standard impulse currents with waveform 8/20 µs according to IEC, EN,

More information

Technical Specification

Technical Specification EMC TESTS, SEMINARS, HARD AND SOFTWARE Technical Specification No. E-MIG1206-3P.doc Revised: 10.March 2007 1 MIG Tester Type MIG1206-3P 1 MIG Tester Type MIG1206-3P 1 1.1 Introduction 1 2 General 2 2.1

More information

ELECTROSTATIC DISCHARGE SIMULATOR

ELECTROSTATIC DISCHARGE SIMULATOR ELECTROSTATIC DISCHARGE SIMULATOR Designed by HIGH VOLTAGE TEST SOLUTIONS 2 ONYX SUMMARY The ONYX is a state of the art electrostatic discharge simulator available in 16 kv or 30 kv versions. It is the

More information

OPERATION MANUAL ESD - GENERATORS

OPERATION MANUAL ESD - GENERATORS OPERATION MANUAL ESD - GENERATORS SESD 216 SESD 230 OPERATION MANUAL ELECTROSTATIC DISCHARGE GENERATORS SESD 216 SESD 230 16,5 kv 30,0 kv Warning: This unit generates high voltages and is inherently dangerous.

More information

Electrostatic Discharge Simulator. user manual

Electrostatic Discharge Simulator. user manual Electrostatic Discharge Simulator user manual i A Note to Begin Thank you for choosing the Haefely ONYX to meet your ESD testing needs. Please take a little time to read through this user manual and familiarize

More information

EMC PARTNER. ESD MODULAR HANDHELD TESTER Electrostatic Discharge Testing

EMC PARTNER. ESD MODULAR HANDHELD TESTER Electrostatic Discharge Testing EMC PARTNER ESD3000 - MDULAR HANDHELD TESTER Electrostatic Discharge Testing This document has been optimized for electronic media Accredited Calibration Quality at EMC PARTNER is based on an IS 9001 management

More information

Programmable Relay ZEN V2 Units

Programmable Relay ZEN V2 Units Programmable Relay ZEN V2 Units Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Refer to Warranty

More information

Model INSTRUCTION MANUAL DIGITAL MULTIMETER

Model INSTRUCTION MANUAL DIGITAL MULTIMETER Model 57040 INSTRUCTION MANUAL DIGITAL MULTIMETER SAFETY INFORMATION This multimeter has been designed according to IEC 1010 concerning electronic measuring instruments with an overvoltage category (CAT

More information

3156 LEAK CURRENT HiTESTER

3156 LEAK CURRENT HiTESTER 2003 3156 LEAK CURRENT HiTESTER Safety Standards Measuring Instruments The Long-Awaited Bench-type Model Is Here! Leakage Current Measurement Essential for Electrical Safety Because of the risks it poses,

More information

OPERATING INSTRUCTION

OPERATING INSTRUCTION OPERATING INSTRUCTION AUTORANGING MULTIMETER MAX Ω F C 10A MAX every 15 min. COM V SAFETY INFORMATION The following safety information must be observed to insure maximum personal safety during the operation

More information

Autoranging True RMS Multimeter User Manual

Autoranging True RMS Multimeter User Manual Autoranging True RMS Multimeter User Manual Please read this manual before switching the unit on. Important safety information inside. Contents Page 1. Safety Information... 4 2. Safety Symbols... 5 3.

More information

Complimentary Reference Material

Complimentary Reference Material Complimentary Reference Material This PDF has been made available as a complimentary service for you to assist in evaluating this model for your testing requirements. TMG offers a wide range of test equipment

More information

S-14 S-14. Compact Digital Multimeter. Compact Digital Multimeter

S-14 S-14. Compact Digital Multimeter. Compact Digital Multimeter S-14 Compact Digital Multimeter S-14 Compact Digital Multimeter SAFETY INFORMATION The following safety information must be observed to insure maximum personal safety during the operation at this meter

More information

4 channel PD tester for semiconductor test TPP

4 channel PD tester for semiconductor test TPP 4 channel PD tester for semiconductor test TPP New! Up to 18.3kV peak (13kV rms) Multi channel Partial discharge test system for check up the safety electric isolation of electronic components (e.g. opto

More information

OPERATING INSTRUCTION. Pen-Type Digital Multimeter

OPERATING INSTRUCTION. Pen-Type Digital Multimeter OPERATING INSTRUCTION Pen-Type Digital Multimeter International Safety Symbols This symbol, adjacent to another symbol or terminal, indicates the user must refer to the manual for further information.

More information

Multifunction Calibrator

Multifunction Calibrator Multifunction Calibrator Model CL TC - - - C V _ TECPEL CO., LTD. Features:. - (KΩ load, V Loop Supply). -.,-.V, -.V. K, J, E, T Thermocouple ( C and ). Frequency -.. Basic Accuracy. Easy Key-pad Operation.

More information

Millenium 3. General Characteristics. General environment characteristics for CB, CD, XD, XR and XE product types

Millenium 3. General Characteristics. General environment characteristics for CB, CD, XD, XR and XE product types Millenium 3 General Characteristics Millenium 3 Compact Range Millenium 3 Expandable Range Millenium 3 Communication Options Millenium 3 Range General environment characteristics for CB, CD, XD, XR and

More information

After unpacking, check the GL820's Exterior to make sure that there are crack or other damage before use.

After unpacking, check the GL820's Exterior to make sure that there are crack or other damage before use. PRESSURE LOAD TORQUE POSITION ROTARY ANGLE TILT ACCELERATION VIBRATION RATE SIGNAL CONDITIONER DATALOGGER midi LOGGER GL820 Quick Start Guide GL820-UM-851 Thank you for choose the midi LOGGER GL820. This

More information

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/O

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/O Characteristics star-delta timing relay - 230VAC/440VAC - 1 C/O Main Range of product Product or component type Discrete output type Device short name Nominal output current Complementary Contacts type

More information

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/ O

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/ O Characteristics star-delta timing relay - 230VAC/440VAC - 1 C/ O Main Range of product Product or component type Discrete output type Device short name Nominal output current Zelio Time Modular timing

More information

CM-220 True RMS AC CLAMP METER INSTRUCTION MANUAL

CM-220 True RMS AC CLAMP METER INSTRUCTION MANUAL CM-220 True RMS AC CLAMP METER INSTRUCTION MANUAL Safety International Safety Symbols This symbol, adjacent to another symbol or terminal, indicates the user must refer to the manual for further information.

More information

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER SAFETY INFORMATION The following safety information must be observed to ensure maximum personal safety during the operation of this meter: This meter is

More information

MOTOR ARMATURE TESTER

MOTOR ARMATURE TESTER MOTOR ARMATURE TESTER 6920 ENGLISH MANUAL 1 st Oct 2008 CATALOG BEFORE USE...1 1.1 Product Introduction...1 1.2 Product Characteristic...1 2 SPEC INSTRUCTION...2 3 SAFETY INSTRUCTION...4 4 INSTALLATION...6

More information

Control Panel CP600 CP651, CP651-WEB

Control Panel CP600 CP651, CP651-WEB DATA SHEET Control Panel CP600 CP651, CP651-WEB 1 Ordering Data Part No. Description Product Life Cycle Phase 1SAP551100R0001 CP651, control panel, TFT graphical display, single-touch screen, 10.4, Active

More information

ELECTROSTATIC FIELDMETER

ELECTROSTATIC FIELDMETER ELECTROSTATIC FIELDMETER Small hand-held Electro-Fieldmeter with digital display designed to measure electrostatic voltage potentials (with pre-selected distance) according the fieldmill influence principal.

More information

INSTRUCTION MANUAL. AUTOMATIC INSULATION WITHSTANDING HiTESTER

INSTRUCTION MANUAL. AUTOMATIC INSULATION WITHSTANDING HiTESTER INSTRUCTION MANUAL 3153 AUTOMATIC INSULATION WITHSTANDING HiTESTER Contents Introduction Inspection Safety Notes Notes on Use Chapter Summary i i ii v vi Chapter 1 Overview 1 1.1 Product Introduction

More information

ETHOS Auto Ranging Digital Multimeter

ETHOS Auto Ranging Digital Multimeter ETHOS 5020 Auto Ranging Digital Multimeter 1 1. SAFETY INFORMATION SAFETY SYMBOLS Warning! Dangerous Voltage (Risk of electric shock). Caution! Refer to the user s manual before using this Meter. Double

More information

Conforms to VDE0435/2021 C/250, VDE0110, VDE0106/P100 Conforms to EN , pren

Conforms to VDE0435/2021 C/250, VDE0110, VDE0106/P100 Conforms to EN , pren Solid-state Power OFF-delay Timer II DIN 22.5-mm Solid-state Power OFF-delay Timer High immunity to invertor noise. Long power OFF-delay times; S-series: up to 12 seconds, L-series: up to 120 seconds.

More information

LM903 Fluid Level Detector

LM903 Fluid Level Detector LM903 Fluid Level Detector General Description The LM903 uses the thermal-resistive probe technique to measure the level of nonflammable fluids A low fluid level is indicated by a warning lamp operating

More information

Control Panel CP600 CP635, CP635-B, CP635-WEB

Control Panel CP600 CP635, CP635-B, CP635-WEB DATA SHEET Control Panel CP600 CP635, CP635-B, CP635-WEB 1 Ordering Data Part No. Description Product Life Cycle Phase 1SAP535100R0001 CP635, control panel, TFT graphical display, single-touch screen,

More information

Part No. Z , IA Jul OPERATION MANUAL. High Voltage Digitalmeter A

Part No. Z , IA Jul OPERATION MANUAL. High Voltage Digitalmeter A Part No. Z1-109-820, IA001705 Jul. 2016 OPERATION MANUAL High Voltage Digitalmeter 149-10A Use of Operation Manual Please read through and understand this Operation Manual before operating the product.

More information

ATS CONTROLLER OPERATING MANUAL

ATS CONTROLLER OPERATING MANUAL HAT600 Series HAT600/HAT600I/HAT600B/HAT600BI ATS CONTROLLER OPERATING MANUAL Smartgen Electronic CONTENT 1 SUMMARY... 4 2 PERFORMANCE AND CHARACTERISTICS... 4 3 SPECIFICATION... 5 4 OPERATING... 6 4.1

More information

INSTRUCTION SHEET. Eaton Logic Controller ELCB Controllers

INSTRUCTION SHEET. Eaton Logic Controller ELCB Controllers 2010-12-10 5011699201-PBB1 Eaton Logic Controller ELCB Controllers INSTRUCTION SHEET [Applicable Controllers] ELCB-PB10 ELCB-PB14 ELCB-PB20 ELCB-PB30 ELCB-PB40 IL05001005E 002-1310020-02 Thank you for

More information

USER'S MANUAL DCL-650

USER'S MANUAL DCL-650 USER'S MANUAL Clamp on Multimeter - Compact Design True RMS AC/DC DCL-650 CIRCUIT-TEST ELECTRONICS www.circuittest.com Safety International Safety Symbols This symbol, adjacent to another symbol or terminal,

More information

Can eliminate static charge over an extensive range

Can eliminate static charge over an extensive range No.BK-P3 Static Electricity Removing Unit Ionizer Wide Area Fan Type Overhead Fan Type Can eliminate static charge over an extensive range Wide area fan type RoHS compliant product Overhead fan type Static

More information

Swift Responses with Accurate Measurement

Swift Responses with Accurate Measurement Swift Responses with Accurate Measurement The /1503D are equipped with the excellent transient recovery time, which can, in less than 40us, recover the output voltage to within 100mV of the previous voltage

More information

DATA ACQUISITION SYSTEMS Stand-alone & with Recorder Portable, 1 to 16 Channels

DATA ACQUISITION SYSTEMS Stand-alone & with Recorder Portable, 1 to 16 Channels Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) FALCON Models TA220-1000 Series DATA ACQUISITION SYSTEMS Stand-alone & with Recorder Portable, 1 to 16 Channels The

More information

User Manual. 400Amp AC Clamp Meter + NCV. Model MA430. Additional User Manual Translations available at

User Manual. 400Amp AC Clamp Meter + NCV. Model MA430. Additional User Manual Translations available at User Manual 400Amp AC Clamp Meter + NCV Model MA430 Additional User Manual Translations available at www.extech.com Introduction Congratulations on your purchase of this Extech MA430 Clamp Meter. This

More information

MANUAL PCE-123

MANUAL PCE-123 www.pce-industrial-needs.com Tursdale Technical Services Ltd Unit N12B Tursdale Business Park Co. Durham DH6 5PG United Kingdom Phone: +44 ( 0 ) 191 377 3398 Fax: +44 ( 0 ) 191 377 3357 info@tursdaletechnicalservices.co.uk

More information

RM22LA32MR Level control relay RM22-L V AC/DC - 2 C/O

RM22LA32MR Level control relay RM22-L V AC/DC - 2 C/O Product datasheet Characteristics RM22LA32MR Level control relay RM22-L - 24..240 V AC/DC - 2 C/O Main Range of product Product or component type Relay type Relay name Relay monitored parameters Time delay

More information

TVU1240R1A Product Engineering Specification

TVU1240R1A Product Engineering Specification TVU1240R1A Product Engineering Specification 1. Scope This specification is applied to protect sensitive electronic circuits from the threat of electrostatic discharge (ESD). The function meets with the

More information

Micro-Ohmmeter Model 6292

Micro-Ohmmeter Model 6292 Micro-Ohmmeter Model 6292 Quick Start Guide ENGLISH www.aemc.com CHAUVIN ARNOUX GROUP Statement of Compliance Chauvin Arnoux, Inc. d.b.a. AEMC Instruments certifies that this instrument has been calibrated

More information

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description Inline Block IO Module for PROFIBUS With 32 Digital Outputs AUTOMATIONWORX Data Sheet 6889_en_04 Description PHOENIX CONTACT - 03/2007 & & ' ) The ILB PB 24 DO32 module is designed for use within a PROFIBUS

More information

HAT600 Series HAT600/HAT600I/HAT600B/HAT600BI ATS CONTROLLER USER MANUAL

HAT600 Series HAT600/HAT600I/HAT600B/HAT600BI ATS CONTROLLER USER MANUAL HAT600 Series HAT600/HAT600I/HAT600B/HAT600BI ATS CONTROLLER USER MANUAL ZHENGZHOU SMARTGEN TECHNOLOGY CO.,LTD CONTENT 1 OVERVIEW... 5 2 PERFORMANCE AND CHARACTERISTICS... 6 3 SPECIFICATION... 8 4 OPERATING...

More information

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O Characteristics Ondelay Timing Relay 0.05s 300h 24 240V AC/DC 2C/O Main Range of product Product or component type Discrete output type Device short name Nominal output current Zelio Time Modular timing

More information

OPERATOR S INSTRUCTION MANUAL DIGITAL MULTIMETER

OPERATOR S INSTRUCTION MANUAL DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL DIGITAL MULTIMETER SAFETY INFORMATION This multimeter has been designed according to IEC 1010 concerning electronic measuring instruments with an overvoltage category (CATⅡ)

More information

EGA10603V12A1-B Engineering Specification

EGA10603V12A1-B Engineering Specification RoHS Pb EGA10603V12A1- Engineering 1. Scope This specification is applied to electrostatic discharge (ESD) protection. It is designed to protect the high-speed data lines against ESD transients. It has

More information

ATK-2040 AC/DC TRMS Watt Clamp Meter Users Manual

ATK-2040 AC/DC TRMS Watt Clamp Meter Users Manual ATK-2040 AC/DC TRMS Watt Clamp Meter Users Manual EN 61010-2-032 CAT II 600V, CAT III 300V Pollution Degree 2 SYMBOLS showed on the clamp meter or in this manual: Caution, risk of danger. Refer to accompanying

More information

SPECIFICATIONS HAND HELD PARTICLE COUNTER KC Higashimotomachi, Kokubunji, Tokyo , Japan

SPECIFICATIONS HAND HELD PARTICLE COUNTER KC Higashimotomachi, Kokubunji, Tokyo , Japan SPECIFICATIONS HAND HELD PARTICLE COUNTER KC-52 3-20-41 Higashimotomachi, Kokubunji, Tokyo 185-8533, Japan No. 10017-3E 18-04 Printed in Japan Outline The hand held particle counter KC-52 is designed to

More information

ME162 Single-Phase Electronic Meter

ME162 Single-Phase Electronic Meter www.universalmeterservices.co.uk Energy Measurement and Management ME162 Single-Phase Electronic Meter Technical Description Version 0.1, 01.07. 2004 Index: 1. Meter configuration... 3 2. Energy measurement

More information

RT4F-110V/25A RECTIFIER

RT4F-110V/25A RECTIFIER The RT4F-110V/25A is a hot-pluggable switched mode rectifier (SMR) module designed to provide up to 25A of output current into a 110V nominal system. Examples of such systems are 60 cells lead acid (136V

More information

Control Panel CP600 CP635-FB, CP635-FW

Control Panel CP600 CP635-FB, CP635-FW DATA SHEET Control Panel CP600 CP635-FB, CP635-FW 1 Ordering Data Part No. Description Product Life Cycle Phase 1SAP535110R6001 CP635-FB, control panel, TFT graphical display, single-touch projected Active

More information

Fully-Automated Multi-Function Electrical Safety Compliance Analyzers

Fully-Automated Multi-Function Electrical Safety Compliance Analyzers Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) OMNIA Series Fully-Automated Multi-Function Electrical Safety Compliance Analyzers U.S. Patent Nos. (6,054,865, 6,011,398,

More information

AC/DC Peak Voltmeter, Types MU17 and MU18

AC/DC Peak Voltmeter, Types MU17 and MU18 HIGHVOLT Prüftechnik Dresden GmbH Marie-Curie-Straße 10 01139 Dresden, Phone +49 351 845 700 Fax +49 351 845 679 E-mail sales@highvolt.de Web http://www.highvolt.de Data Sheet 5.56/7 AC/DC Peak Voltmeter,

More information

PDD-300 pulsed diode driver

PDD-300 pulsed diode driver rev 1.08 / 2019 02 13 PDD-300 pulsed diode driver User manual Warning! This equipment may be dangerous. Please read user manual before starting operations. Important note. Please measure output with adequate

More information

Control Panel CP600-eCo CP604, CP604-B

Control Panel CP600-eCo CP604, CP604-B DATA SHEET Control Panel CP600-eCo CP604, CP604-B 1 Ordering Data Part No. Description Product Life Cycle Phase 1SAP504100R0001 CP604, control panel, TFT graphical display, single-touch screen, 4.3, Active

More information

EMC PARTNER. ESD MODULAR HANDHELD TESTER Electrostatic Discharge Testing

EMC PARTNER. ESD MODULAR HANDHELD TESTER Electrostatic Discharge Testing EMC PARTNER ESD3000 - MDULAR HANDHELD TESTER Electrostatic Discharge Testing Accredited Calibration Quality at EMC PARTNER is based on an IS 9001 management system. This is the foundation for an IS 17025

More information

ADAPTER SERIES SST-AD60-C

ADAPTER SERIES SST-AD60-C ADAPTER SERIES SST-AD60-C Compact, intelligent multi-voltage 60W USB Type-C adapter Maximum 60W 3A fast charging for USB Type-C equipped laptops, tablets, and mobile phones Intelligent detection and auto

More information

Digital Speed Controller User Manual

Digital Speed Controller User Manual Diesel Engine for Generators Digital Speed Controller User Manual (DSC-1000) Ver_1.0 Doosan Infracore 페이지 1 / 36 Contents 1. Product Overview and General Specification 1.1 Product Information 1.2 Product

More information

User's Guide. MiniTec TM Series Model MN25 MultiMeter

User's Guide. MiniTec TM Series Model MN25 MultiMeter User's Guide MiniTec TM Series Model MN25 MultiMeter Warranty EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for one year from date of shipment (a

More information

Solid-state Timer. Ordering Information. Specifications. Miniature Timer Compatible with the MY Relay. Accessories. Time Ranges

Solid-state Timer. Ordering Information. Specifications. Miniature Timer Compatible with the MY Relay. Accessories. Time Ranges Solid-state Timer Miniature Timer Compatible with the MY Relay Large transparent time-setting knob facilitates time setting. Flat-blade and Phillips screwdrivers can also be used for time setting. Approved

More information

Advanced Test Equipment Rentals ATEC (2832)

Advanced Test Equipment Rentals ATEC (2832) Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) Programmable DC Power Supply MODEL 62000P SERIES PROGRAMMABLE DC POWER SUPPLY MODEL 62000P SERIES Chroma's new 62000P

More information

Techno Instrumentation(India) Pvt. Ltd. Manufacturer of underground power cable fault locators

Techno Instrumentation(India) Pvt. Ltd. Manufacturer of underground power cable fault locators Techno Instrumentation(India) Pvt. Ltd. Manufacturer of underground power cable fault locators Surge Generator T-1016(10) For fault location in LT to HT 11 kv cables. Inbuilt DC high voltage testing up

More information

Solid-state Timer. Ordering Information. Miniature Timer with Multiple Time Ranges and Multiple Operating Modes H3YN- - Accessories (Order Separately)

Solid-state Timer. Ordering Information. Miniature Timer with Multiple Time Ranges and Multiple Operating Modes H3YN- - Accessories (Order Separately) Solid-state Timer Miniature Timer with Multiple Time Ranges and Multiple Operating Modes Minimizes stock. Pin configuration compatible with MY Power Relay. Standard multiple operating modes and multiple

More information

TVU1240R1A Engineering Specification

TVU1240R1A Engineering Specification Part : TVU1240R1A Version : A6 Page : 1 / 10 SCOPE TVU1240R1A Engineering Specification This specification is applied to protect sensitive electronic circuits from the threat of electrostatic discharge

More information

OWNER S MANUAL 9908-TE. HIGH PRECISION AUTO-RANGING DC/True RMS AC BENCH-TOP DIGITAL MULTIMETER

OWNER S MANUAL 9908-TE. HIGH PRECISION AUTO-RANGING DC/True RMS AC BENCH-TOP DIGITAL MULTIMETER OWNER S MANUAL 9908-TE HIGH PRECISION AUTO-RANGING DC/True RMS AC BENCH-TOP DIGITAL MULTIMETER IMPORTANT! Read and understand this manual before using the instrument. Failure to understand and comply with

More information

ACL 350 Digital Static Locator

ACL 350 Digital Static Locator ACL 350 Digital Static Locator OPERATION MANUAL Meter is warranted for one year from the date of purchase on parts and labor. Calibration is recommended every twelve months. 840 W. 49 th Place Page 1 of

More information

CBA 1000 Circuit Breaker Analyzer and MicroOhmmeter

CBA 1000 Circuit Breaker Analyzer and MicroOhmmeter Circuit Breaker Analyzer and MicroOhmmeter Circuit Breaker timing test set. 16 timing channels. Up to 4 trip/close coils control. Motion and speed analyzer. Suitable for EHV, HV and MV circuit breakers.

More information

SIRIUS 200 U1X200A SRS U1X200A SRS USER S MANUAL

SIRIUS 200 U1X200A SRS U1X200A SRS USER S MANUAL SIRIUS 200 U1X200A12-310-SRS U1X200A24-310-SRS USER S MANUAL Belgrade, March 2005 CONTENTS 1 GENERAL 1.1. IMPORTANT NOTICES 2 TECHNICAL SPECIFICATIONS 2.1. INPUT (MAINS) 2.2. OUTPUT 2.3. ENVIROMENTAL CONDITIONS

More information

Varistors(SMD) Countermeasure for Surge and Static Electricity

Varistors(SMD) Countermeasure for Surge and Static Electricity (1/1) Varistors(SMD) Countermeasure for Surge and Static Electricity Conformity to RoHS Directive AVR Series AVR-M, AVRL Types Varistor (Variable resistor) is a nonlinear resistive element of the voltage

More information

RE17LAMW on-delay timing relay - 1 s..100 h V AC/DC - solid state output

RE17LAMW on-delay timing relay - 1 s..100 h V AC/DC - solid state output Characteristics on-delay timing relay - 1 s..100 h - 24..240 V AC/DC - solid state output Complementary Control type Voltage range Main Range of product Product or component type Discrete output type Width

More information

Circuit Breaker Analyzer & Timer CAT126

Circuit Breaker Analyzer & Timer CAT126 Robust design for field use Timing and motion measurement 12 timing channels (3x4) for main and resistive contacts 6 timing channels for auxiliary inputs 3 transducer input channels 4 additional analog

More information

Programmable Digital Controlled DC Power Supplies

Programmable Digital Controlled DC Power Supplies Smart choice for power Programmable Digital Controlled DC Power Supplies High Power and Performance for: ATE Bulk Power Production Test OEM Burn-in www.xantrex.com XDC Series Digital Power Supplies 6 kw

More information

Varistors(SMD) Countermeasure for Surge and Static Electricity

Varistors(SMD) Countermeasure for Surge and Static Electricity (1/1) Varistors(SMD) Countermeasure for Surge and Static Electricity Conformity to RoHS Directive AVR Series AVR-M, AVRL Types Varistor (Variable resistor) is a nonlinear resistive element of the voltage

More information

SEL-734B Data Sheet. Advanced Monitoring and Control System. Major Features and Benefits

SEL-734B Data Sheet. Advanced Monitoring and Control System. Major Features and Benefits Advanced Monitoring and Control System Compact Enclosure Full-Size Enclosure Major Features and Benefits The SEL-734B combines volt/var based capacitor bank control with power quality monitoring and advanced

More information

Part No. Z , IA Mar OPERATION MANUAL. High Voltage Digitalmeter A

Part No. Z , IA Mar OPERATION MANUAL. High Voltage Digitalmeter A Part No. Z1-109-820, IA001704 Mar. 2011 OPERATION MANUAL High Voltage Digitalmeter 149-10A Use of Operation Manual Please read through and understand this Operation Manual before operating the product.

More information

Solid-state Timer H3YN

Solid-state Timer H3YN Solid-state Timer H3YN Miniature Timer with Multiple Time Ranges and Multiple Operating Modes Minimizes stock. Pin configuration compatible with MY Power Relay. Standard multiple operating modes and multiple

More information

11 Series - Light Dependent Relay A. Features pole 17.5 mm wide. 1 pole zero hysteresis 4 position selector

11 Series - Light Dependent Relay A. Features pole 17.5 mm wide. 1 pole zero hysteresis 4 position selector Features 11.31 11.41 Relays for automatic control of lighting according to ambient light level - with separate light sensor 11.31-1 NO 16 A output contact Sensitivity adjustment from 1 to 100 lux One module,

More information

INPAQ Global RF/Component Solutions

INPAQ Global RF/Component Solutions TVL 0402 01 AB1 Specification Product Name Series Part No Transient Voltage Suppressor TVS Series TVL 0402 01 AB1 Size EIA 0402 TVL 0402 01 AB1 Engineering Specification 1. Scope TVL 0402 01 AB1 is a TVS

More information

Safety Standards. Model Number:

Safety Standards. Model Number: 150AAS12 F/B Highlights & Features Meet DOE Level VI and ErP Lot 7 Safety Approvals to IEC 60601-1 3.1rd ed. & IEC 60950-1 Compliant with IEC 60601-1-2 4th Ed. Requirements Low touch current (

More information

INPAQ Global RF/Component Solutions

INPAQ Global RF/Component Solutions TVU1240R1A Specification Product Name Series Part No ESD Guard TM Array TVU Series TVU1240R1A Size EIA 1004 TVU1240R1A Product Engineering Specification 1. Scope This specification is applied to protect

More information

2 keys Touch Pad Detector IC

2 keys Touch Pad Detector IC 2 keys Touch Pad Detector IC Outline The TonTouch TM IC is capacitive sensing design specifically for touch pad controls. The device built in regulator for touch sensor. Stable sensing method can cover

More information

Operating Instructions

Operating Instructions Bracken Hill South West Industrial Estate Peterlee Co Durham SR8 2SW ENGLAND Tel: +44(0)191 5863511 www.seaward.co.uk sales@seaward.co.uk service@seaward.co.uk Part Number 344A550 Revision 1 2006 Seaward

More information

DX4085 Z-Meter Tester

DX4085 Z-Meter Tester DX4085 Z-Meter Tester AC Resistance ( ACR ) Measurement Figure-of-Merit ( Z ) Measurement Time Constant ( t ) Measurement dtmax estimations (for single-stage TECs) External TEC Clips USB Interface for

More information

Table of Contents. Safety. Attention. Warnings

Table of Contents. Safety. Attention. Warnings Solstart Miniature Soft Starter 8-58A, 220-600V Instruction Manual Ver. 21.2. 2002 Table of Contents Page Subject 3 Starter Selection 4 Installation Notes 5 Wiring 6 Starter Settings & Start-up Procedure

More information

99 Washington Street Melrose, MA Phone Toll Free Visit us at INSTRUCTION MANUAL

99 Washington Street Melrose, MA Phone Toll Free Visit us at   INSTRUCTION MANUAL 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com INSTRUCTION MANUAL Test Equipment Depot - 800.517.8431-99 Washington Street Melrose,

More information

Circuit Breaker Analyzer & Timer CAT65

Circuit Breaker Analyzer & Timer CAT65 Safe and fast testing with BSG (Both Sides Grounded) Timing and motion measurement 6 timing channels (3x2) for main and resistive contacts 6 timing channels for auxiliary inputs 3 transducer input channels

More information

Continuous Measurement up to 43 MS/s

Continuous Measurement up to 43 MS/s Continuous Measurement up to 43 MS/s Time Interval Analyzer Maximum continuous sampling rate 43 Ms/s Maximum sampling size 0 9 data samples 25 ps measurement resolution 00 ps internal jitter Built-in printer

More information

Operating Instructions

Operating Instructions PRIMETEST 100 PRIMETEST 100 Bracken Hill South West Industrial Estate Peterlee Co Durham SR8 2SW ENGLAND Tel: +44(0)191 5863511 www.seaward.co.uk sales@seaward.co.uk service@seaward.co.uk Part Number

More information

Solid-state Timer. Ordering Information. Ultra-slim Timer for G2R Relay Socket. H3RN-jj. Accessories (Order Separately) Connecting Socket

Solid-state Timer. Ordering Information. Ultra-slim Timer for G2R Relay Socket. H3RN-jj. Accessories (Order Separately) Connecting Socket Solid-state Timer Ultra-slim Timer for G2R Relay Socket Pin configuration compatible with G2R Relay and mounts to the P2R/P2RF Socket. Standard multiple time ranges and multiple operating modes. Conforms

More information

RM4LA32M liquid level control relay RM4-L V AC

RM4LA32M liquid level control relay RM4-L V AC Characteristics liquid level control relay RM4-L - 220..240 V AC Complementary [Un] rated nominal voltage Operating voltage tolerance Width Output contacts Maximum electrode voltage Maximum electrode current

More information

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26 E39.0.31.6C-02 Data logger for humidity temperature as of version V1.0 Operating Manual T-Logg 160 GREISINGER electronic GmbH D - 93128 Regenstauf, Hans-Sachs-Straße 26 +49 (0) 9402 / 9383-0 +49 (0) 9402

More information

Multifunctional time delay relay MFT U31S, MFT U41SE

Multifunctional time delay relay MFT U31S, MFT U41SE 8 Functions, 8 time ranges Multivoltage: 24 Vac / dc 110... 240 Vac 2 output contacts MFT U31S Functions E Delay on E Delay on - version with control contact as opening contact A Delay off without auxiliary

More information

Digital Clamp Meter User Manual

Digital Clamp Meter User Manual Compact AC, AC/DC Digital Clamp Meter User Manual Please read this manual before switching the unit on. Important safety information inside. Contents 1.Safety... 3 2.Safety Notes... 3 3.Warnings... 3 4.Cautions...

More information

3153 Instruction Manual

3153 Instruction Manual 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com 3153 Instruction Manual AUTOMATIC INSULATION/ WITHSTANDING HiTESTER Mar. 2017 Revised

More information

EARTH RESISTANCE & RESISTIVITY TESTER

EARTH RESISTANCE & RESISTIVITY TESTER 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com BST-ET103 EARTH RESISTANCE & RESISTIVITY TESTER INSTRUCTION MANUAL INDEX 1. INTRODUCTION...

More information

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: 61-796 The Service Information provides the following information: Precautions and safety information Specifications Performance test procedure Calibration