1 PCe Type CAe Type Compliance Data: ATEX - IEC: ATEX IEC CE Ex ia IIC; Ex ib IIC T6 to T2 Ex td A21 T0 C to T290 C Ex de IIC Operating Temperatures: -40 C to +55 C (CAe) -55 C to +60 C (PCe) 223 ATX Product Catalog
2 Applications: Designed for use in Zone 1 or 2 areas where flammable gases or vapors are present either continuously or intermittently. Ideal for use in wet or corrosive atmospheres. Petroleum, chemical, refineries and other industrial process facilities. Designed for use in Zone 21 or 22 areas where flammable dusts are present either continuously or intermittently. Food processing, dairy, brewing and other commercial facilities. JBEA Series: Terminal junction boxes for electrical low voltage and instrumentation connections in hazardous areas. Refer to technical data to define permitted number of terminal blocks and cable entries on selected junction boxes. ECEA Series: Enclosure for distribution and control applications can be customized at our workshop to house a large range of components; i.e. control units, switches, breakers, transformers, meters, etc. Catalog Number Logic: Series Certified: EC = Enclosure & Controls, Control Stations JB = Junction Box E = Increased Safety I = Intrinsic Safety A = Aluminum Features: Operating temperature -55 C to +60 C (PCe) and -40 C to +55 C (CAe). Standard Materials: Gray painted marine grade aluminum alloy. Stainless steel hardware. Accessories: Rail mounting. Refer to technical data to define permitted number and size of terminals and cable entries. Options: Nameplates. Please consult us for: - Enclosures custom drilled and assembled at our factory. - Empty enclosure with Ex U component marking for re-certification by notified body for CAe type. JBEA XX XX XX X Dimensions Length (mm): 12 = = = = = = 40 Dimensions Width (mm): 11 = 1 20 = = 30 Dimensions Depth (mm): 09 = = = 190 Options: U = Component Certification U # = Customized Enclosure #: 6 Digit number will be assigned at time of order placement. Ordering Information: JBEA Series: Aluminum Junction Boxes For use with Ex certified terminals only (not supplied). Mounting rails supplied. Yellow laminated plastic label with black lettering. Dimensions Rail Length Maximum Weight Volume Catalog Old Catalog Type L x W x D (mm) W (mm) (kg) (dm 3 ) Number Number PCe1 120 x 1 x JBEA PCe2 170 x 1 x JBEA PCe3 230 x 1 x JBEA CAe1 215 x 205 x JBEA CAe2 320 x 205 x JBEA CAe3 425 x 205 x JBEA CAe5 40 x 30 x JBEA ECEA Series: Aluminum Enclosure for Distribution and Control Applications Designed to house a large range of components; i.e. control units, switches, breakers, transformers, meters, etc. Must be customized at our workshop with the following Catalog Number: Replace JB with EC, and add last digits and # for customized boxes. Example: ECEA # ATX Product Catalog 224
3 Mounting Accessories: Enclosure Type Rail Length (mm) Catalog Number Pack TS35 Zinc Plated Symmetrical Steel Rail For direct fixing. Set of two 60 mm height spacers supplied. CAe1 191 JBEP DR215 1 CAe2 293 JBEP DR320 1 CAe3 400 JBEP DR425 1 Description Catalog Number Pack Insulated Side Support for CAe Type Set of Two For mounting symmetrical, asymmetrical rails and copper bar 12 x 2 mm or 12 x 4 mm. See dimensional data page for more details. Description Bar Length (mm) Catalog Number Pack Copper Bar (12 x 4 mm) Copper bar not perforated for cable clamps. Description Catalog Number Pack Cable Clamp for Copper Bar (12 x 4 mm) mm 2 to 4 mm 2 capacity mm 2 to 16 mm 2 capacity Technical Data: JBEA Series. The size of junction box needed to meet your requirements can be selected based upon the table shown below. We also offer you the option to drill and equip using guides G0002 available online at: 1) Define maximum cable entries according Cable Entry Number of to number of modules available per side. Metric Thread Modules M20 1 M25 1 M32 1 M40 2 M50 3 Dimensions (mm) Number of Modules Allowable Max. Type Length Width Depth A/C B/D Size PCe M25 PCe M32 PCe M32 CAe M50 CAe M50 CAe M50 CAe M ATX Product Catalog
4 Technical Data Continued: 2) Maximum rail arrangement according to physical dimensions. H Maximum Quantity of Horizontal Rails Terminal Capacity (mm 2 ) H (mm) PCe1/2/ CAe1/2/ CAe ) Define maximum terminal block quantity according to power dissipation: Junction boxes used for instrumentation applications have very low current levels. Therefore there is no risk of overheating whatever the number of terminals inside the box. For applications other than instrumentation, the following tables allow you to define your junction box depending on the number of terminals and the maximum authorized current being carried with feed-through terminals. For single feed terminals using cross connection, please consult factory for calculation. T Rating: Type Ta +40 C PCe1 PCe2 PCe3 Ta +60 C 120 x 1 x 95 mm 170 x 1 x 95 mm 230 x 1 x 95 mm 2.5 mm 2 Qty A A A 4 mm 2 Qty A 2 6 mm 2 Qty A A mm 2 Qty A 6 50 A 50 A T Rating: Type Ta +40 C CAe1 CAe2 CAe3 CAe5 Ta +55 C 215 x 205 x 130 mm 320 x 205 x 130 mm 425 x 205 x 130 mm 40 x 30 x 190 mm 2.5 mm 2 Qty mm 2 Qty mm 2 Qty mm 2 Qty. 40 A A mm 2 Qty. 2 A 27 A A A 25 mm 2 Qty A 73 A 69 A 60 A 35 mm 2 Qty. 79 A 6 A 0 A 12 0 A For other terminal block configurations, please consult our guide G0002 available online at: ATX Product Catalog 226
5 Compliances: Hazardous Area Gas Dust Certification Type PCe Zones Conforming to ATEX 94/9/CE CE 001 II 2 G CE 001 II2 D Symbol of Protection ATEX Symbol of Protection IEC T Rating Ex ia IIC Ex ib IIC Ex de IIC T6 (+40 C) T5 (+60 C) Ex td A21 Surface Temperature NA T0 C to T95 C Ambient Temperature -55 C to +60 C CE Declaration of Conformity ATEX Certificate LCIE 00 ATEX 6047 IEC Certificate LCIE Ex Other Certifications Index of Protection (solid and liquid) Impact Resistance (shock) GOST IP66 IK Hazardous Area Gas Dust Certification Type CAe U Zones Conforming to ATEX 94/9/CE 001 II 2 G 001 II2 D Symbol of Protection ATEX Symbol of Protection IEC NA Ex td A21 T Rating NA NA Surface Temperature NA NA Ambient Temperature CE Declaration of Conformity ATEX Certificate IEC Certificate -40 C to +55 C 5C241 LCIE 09 ATEX 3036 U LCIE Ex U Other Certifications Index of Protection (solid and liquid) Impact Resistance (shock) IP66 IK Hazardous Area Gas Dust Certification Type CAe Zones Conforming to ATEX 94/9/CE CE 001 II 2 G CE 001 II2 D Symbol of Protection ATEX Symbol of Protection IEC Ex ia IIC Ex ib IIC Ex de IIC Ex td A21 T Rating T6 to T2 NA Surface Temperature NA T0 C to T290 C Ambient Temperature -40 C to +55 C CE Declaration of Conformity ATEX Certificate LCIE 02 ATEX 624X IECEx Certificate IECEx LCI X Other Certifications Index of Protection (solid and liquid) Impact Resistance (shock) GOST IP66 IK Standards: Ex Standards EN / IEC ; ; ; ; ; ; Product Standards EMC Standards Other Standards EN / IEC (IP); (IK) 227 ATX Product Catalog
6 Dimensions (mm): PCe1 to PCe3 CAe1 to CAe5 Dimensions (mm) External Internal Fixings Type A B C D E F G H Thick Ø PCe PCe PCe CAe CAe CAe CAe Insulated Side Support (Rail Holder) Equipment Capacity Type L(mm) M (mm) CAe CAe CAe CAe ATX Product Catalog 22
ATX JBEA and ECEA Series Aluminum Enclosures Increased Safety
Applications Designed for use in Zone 1 or 2 areas where flammable gases or vapors are present either continuously or intermittently. Ideal for use in wet or corrosive atmospheres. Petroleum, chemical,
More informationJunction Boxes & Enclosures JBEP and ECEP Series: Undrilled Fiberglass Reinforced Polyester Enclosures Increased Safety
CSPe Type Small Version CAe Type Non-Hinged Version CAe Type Hinged Versions Compliance Data: ATEX - IECEx: Zone 1 & 1 & ATEX II GD IECEx CE Ex e II T6 to T Ex td A1 T75 C to T95 C Ex ia IIC; Ex ib IIC
More informationControl Stations & Switches: Switches, Circuit Breakers and "Break Glass" Call Points SWE Series: 16 and 20 A Switches Increased Safety
SWE Series: 16 and 2 A Switches Increased Safety 16 A Version - Type 1 16 A Version - Type 2 2 A Version Compliance Data: ATEX - IEC: Zone 1 & 2, 21 & 22 ATEX IEC CE Ex de IIC T6 Ex td A21 T8 C IP66 -
More informationMRE Series 16 and 32 Amp Multiple Socket Outlets Stationary and Portable. Increased Safety
MRE Series 16 and 32 Amp Multiple Socket Outlets Applications Plugs and sockets are used with portable or stationary electrical equipment such as: Lighting systems Conveyors Heaters Motor generators Air
More informationATX MRE Series 16 and 32 Amp Multiple Socket Outlets Stationary and Portable. Increased Safety
Applications Plugs and sockets are used with portable or stationary electrical equipment such as: Lighting systems Conveyors Heaters Motor generators Air conditioning equipment Compressors Pumps For use
More informationCable Glands 757, BVE and 737 Series: Blanking Plugs, Adaptors and Reducers Increased Safety and Flameproof
757 Series Blanking Plugs 737 Series Adaptors and Reducers BVE Series Plastic Blanking Plugs & Sealing Washers Compliance Data: 757 Series Blanking Plugs: ATEX IECEx CE Ex d IIC or Ex e II Ex td A21 IP
More informationSPECIALTY PRODUCTS. Flameproof housing Zones 1-2 and to encase video cameras. Used for onshore and offshore sites and process supervision.
SPECIALTY PRODUCTS Flameproof housing Zones 1-2 and 21-22 to encase video cameras. Used for onshore and offshore sites and process supervision. Description Page Camera Housing eries Video Camera Housings
More informationCable Glands. Description Introduction to Cable Glands 399. EEXe Series EEXe Series. A2F, E1FX/E2FX, E1FW/E2FW and T3 Series
Description Page Introduction to Cable Glands 399 EEXe Series 400-401 Polyamide Cable Glands for Unarmored Cable Increased Safety EEXe Series Ex e Certified Ex I Application Entry Thread Seal A2F, E1FX/E2FX,
More informationSIZE 1, 2 AND 3 POLYAMIDE PRE-DRILLED CONTROL STATIONS
SIZE, AND POLYAMIDE PRE-DRILLED CONTROL STATIONS 0986 00 0986 0 0986 0 0986 8 Size, and pre-drilled control stations with component fixed on the base* Compact enclosure, polyamide body and cover x M0 clearance
More informationViamaster LED Series Luminaires For ATEX and IECEx Governed Hazardous Locations
Applications For use in locations where: Flammable gases, vapors and dusts are present A high degree of corrosion resistance is required Protection against dirt, water and moisture is necessary Typical
More informationEx Junction Boxes & Control Stations
www.fibox.com Ex Junction Boxes & Control Stations Fibox Oy Ab Keilaranta D Espoo, Finland Tel. + () Fax. + () E-mail: info@fibox.fi Homepage: www.fibox.com Fibox Ltd. -, Songdo-Dong, Yeonsu-Gu, Incheon,
More informationActuators. Stackable Contact Blocks (1, 2, or 3) with Contact Blocks
Unicode 2 Series: Actuators, Pilot Lights, Contact Blocks, Switches and Accessories Actuators Stackable Contact Blocks (, 2, or 3) Pilot Light Stackable Pilot Light with Contact Blocks Panel Mounting Adaptor
More informationFELED Series Nonmetallic LED Luminaires Standard and Emergency Battery Back-Up, Increased Safety
Zone and - and Applications For use in locations where: Hazardous areas are designated as Zone and and A high degree of corrosion resistance is required Protection against dirt, water and moisture is necessary
More informationP Series PlexPower Distribution Panelboards Increased Safety
Applications The P Series PowerPlex panelboard provides indoor and outdoor protection and control of electrical circuits in hazardous environments such as: Petroleum plants Chemical plants Refineries Other
More informationPHOENIX CONTACT - 01/2008
Ex Basic Terminal Blocks for Intrinsically Safe Signals With Knife Disconnection and Test Connections INTERFACE Data Sheet 102957_00_en PHOENIX CONTACT - 01/2008 1 Description PI-EX-TB and PI-EX-TB/T Ex
More informationGrounding Systems / Ground Monitoring Device Series 8146/5075 and 8125/5071
www.stahl.de > Monitored electrostatic grounding of tank containers and drums during loading > Continuous monitoring of correct grounding > Robust design > Weather-protected plastic enclosure (IP66) or
More informationPlexPower Factory Sealed Panelboard Increased Safety
Applications The IEC PlexPower factory sealed panelboard provides indoor and outdoor protection and control of electrical circuits in hazardous environments such as: Petroleum plants Chemical plants Refineries
More informationLS 6600 Technical Datasheet
Technical Datasheet Switch for level detection and dry-run protection Optimised sensor geometry, easy to clean Measures products with dielectric constant > 1.5 Small and compact KROHNE 06/2011-4001367301
More informationATX FELED Series Nonmetallic LED Luminaires Standard and Emergency Battery Back-Up, Increased Safety
Zone and - and Applications For use in locations where: Hazardous areas are designated as Zone and and A high degree of corrosion resistance is required Protection against dirt, water and moisture is necessary
More informationINSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F
PSD1000 - PSD1000F INSTRUCTION MANUAL Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD1000 - Universal AC Input Switching Power Supply 24 Vdc Output ISM0089-4
More informationSensor boxes SRBG Key features
Key features Function SRBG sensor boxes are the compact solution when it comes to electrical feedback signals and monitoring the position of process valves which are actuated with pneumatic quarter turn
More informationViamaster LED Series Luminaires For NEC and CEC Governed Hazardous Locations
Class I, Division, Groups A, B, C, D Class I, Zone, Group IIC Class II, Division, Groups F, G Zone, Group IIIB Type R,, X Applications For use in locations where: Flammable gases, vapors and dusts are
More informationTerminal Boxes Series 8118
> Enclosure made of glass fibre reinforced polyester resin > sizes available > Terminals and cable glands fitted to order > Enclosure design with integrated metal bracket for metal cable glands. > Degree
More informationLinear Luminaire with LED Series 6412/5
> For use in Zones 2, 21 & 22 > Latest LED technology with a high luminous efficacy and a long service life > Extra flat version for low mounting depth > Powder-coated sheet-steel or brushed stainless
More informationMicro Limit Switch Series 8064
> For universal application > Versions with snap-action contact positive opening contact > With connecting cable or with single cores when it is used as a built-in device > Width Single limit switch 11
More informationD5090S INSTRUCTION MANUAL. D A SIL 3 Relay Output Module for NE Load. DIN-Rail and Termination Board, Model D5090S
D5090S INSTRUCTI MANUAL 4 A Relay Output Module for NE, DIN-Rail and Termination Board, Model D5090S D5090-4 A Relay Output Module for NE G.M. International ISM09-3 Characteristics General Description:
More informationDECONTACTOR METAL 20 A/32 A/63 A/125 A/200 A
X ECONTACTOR 20 A/32 A/63 A/125 A/200 A II2 G Ex de IIC, t 1 IP65 water-and dust-tight Integrated load-break switch Locking in connected or disconnected position by keying axis 178 X TECHNIL FEATURES X1
More informationEx-CELL Stainless Steel and Painted Steel Enclosures
Ex-CELL Stainless Steel and Eaton's Crouse-Hinds Ex-CELL Enclosures are manufactured to meet the most demanding industrial and hazardous area environmental applications. The Ex-CELL Series is a globally
More informationProviding flexible power supply and signal connection there, where it is needed even in hazardous areas for the Zones 1and 2.
e X L i n k exlink 7-pole / 6-pole + PE for Zone 1 and Zone 21 Providing flexible power supply and signal connection there, where it is needed even in hazardous areas for the Zones 1and 2. The exlink 7
More informationAssembly. Front view. LED yellow: Relay output. LED red: LB/SC Power Rail
Switch Amplifier Features Assembly -channel isolated barrier 4 V DC supply (Power Rail) Dry contact or NAMUR inputs Relay contact output Line fault detection (LFD) Reversible mode of operation Up to SIL
More informationDeltaV Bulk Power Supplies
DeltaV Distributed Control System Product Data Sheet DeltaV Bulk Power Supplies DeltaV 5 A, 10A, 20 A, 40 A Bulk Power Supplies. DeltaV 20 A, 40 A and 80 A Bulk Power Supply Redundancy Modules. Easy to
More informationGrounding Monitoring Device Series 8485
www.stahl.de > Controlled electrostatic grounding of road tankers and rail cars during loading > Continuous monitoring of correct grounding > The object recognition prevents potential operator errors (with
More informationOperating Instructions 12/2010 MN Z-EN XV-152 MICRO PANEL
Operating Instructions 12/2010 MN04802006Z-EN MICRO PANEL 2 Device description 2.3 Device versions 2.3 Device versions Fig. 1 MICRO PANELs are available in the following versions: Basic device Display
More informationGeneral Specifications
General Specifications Model MLX Loop Powered Process Indicator GS 60A02S01-01E-A The Model MLX Loop-Powered Process Indicator receives DC current signals from electronic transmitters and indicates process
More informationSeries Panel Mounted Control Devices
E_Master2012.qxd:NEW_E_Master_temp.qxd 1/27/12 4:28 PM Page 1 Series Features: Suitable for hazardous and corrosive locations. Installation is easy and precise. Devices fit into a standard 30.5mm, 1.2"
More informationThe Solid-State Decoupler (SSD)
The Solid-State Decoupler (SSD) Installation Instructions Introduction The Solid-State Decoupler (SSD) is a solid-state DC isolation/ac grounding (i.e., coupling) device design ed for use in conjunction
More informationGeneral Specifications
General Specifications Model MLX Loop Powered Process Indicator GS 60A02S01-01E-A The Model MLX Loop-Powered Process Indicator receives DC current signals from electronic transmitters and indicates process
More informationYT-870 / 875 Series. Rotork YTC Limited VERSION 1.06
PRODUCT MANUAL Rotork YTC Limited VERSION 1.06 Contents 1 Introduction... 3 1.1 General Information for the users... 3 1.2 Manufacturer Warranty... 3 1.3 Explosion Proof Warning... 4 2 Product Description...
More informationPHOENIX CONTACT - 12/2007
Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Active Transistor Output, Two-Channel INTERFACE Data Sheet 0943_00_en PHOENIX CONTACT - /007 Description The PI-EX-ME-NAM/TO-A is a two-channel
More informationHMT360 Series Intrinsically Safe Humidity and Temperature Transmitters
HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters For operation in up to Zone 0 / 20 Features Measures humidity and temperature, outputs also dew point, mixing ratio, absolute humidity
More informationGround Monitoring Device Series 8485
www.stahl.de > Controlled electrostatic grounding of road tankers and rail cars during loading > Continuous monitoring of correct grounding > The object recognition prevents potential operator errors (with
More informationPI-EX-ME-2NAM/COC-120VAC
PI-EX-ME-NAM/COC-0VAC Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Relay Output, PDT, Two-Channel, 0 V AC Supply INTERFACE Data Sheet 0944_00_en PHOENIX CONTACT - 0/008 Description
More informationPI-EX-ME-2NAM/COC-24VDC
Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Relay Output, PDT, Two-Channel, 4 V DC Supply INTERFACE Data Sheet 0033_0_en PHOENIX CONTACT - /007 Description The PI-EX-ME-NAM/COC-4VDC
More informationData sheet. Constant current DALI LED control gear 80 W Output power ma Output current Intelligent temperature protection.
Data sheet Constant current DALI LED control gear 8 W Output power 5 7 ma Output current Intelligent temperature protection Linear VI LED Linear VI LED control gear More than 25 years of experience in
More informationLMP 308. Separable Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO / 0.
LMP 08 Separable Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.25 % FSO / 0. % FSO Nominal pressure from 0... mh 2 O up to 0... 250 mh 2 O Output signals 2-wire:
More informationHMT360 Series Intrinsically Safe Humidity and Temperature Transmitters
www.vaisala.com HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters Customers may specify the transmitter configuration when ordering the instrument, however changes in configuration
More informationGeneral Specifications
General Specifications Field Wireless Communication Module GENERAL This General Specification (GS) describes the specifications for Field Wireless Communication Module. This product is based on the industrial
More informationReed sensor For bypass level indicators Model BLR
Level measurement Reed sensor For bypass level indicators Model BLR WIKA data sheet LM 10.04 for further approvals see page 3 Applications Sensor for the continuous level measurement of liquids in bypass
More informationCable Entry Systems for Potentially Explosive Atmospheres
Cable Entry Systems for Potentially Explosive Atmospheres Directive 94/9/EC (ATEX) KEL-ER KVT 80 ATEX stands for ATmosphères EXplosives and is the short name for the European Directive 94/9/EC, regulating
More informationINSTRUCTION MANUAL. SIL 3 Relay Output Module DIN-Rail Models D1092S-069, D1092D-069 D1092S D1092D-069
D09S09 D09D09 INSTRUCTION MANUAL SIL Relay Output Module DINRail Models D09S09, D09D09 D0909 SIL Relay Output Module ISM00 SIL Applications For Safety Related System and SIL, SIL Applications according
More informationHMT360 Series Intrinsically Safe Humidity and Temperature Transmitters
www.vaisala.com HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters Customers may specify the transmitter configuration when ordering the instrument, however changes in configuration
More informationLinear Luminaire with LED Series 6012/5
> For use in Zones 1 & 2, 21 & 22 > Latest LED technology with a high luminous efficacy and a long service life > Extra flat version for low mounting depth > Powder-coated sheet-steel or brushed stainless
More informationExplosionproof Meter Housings
METER HOUSINGS Explosionproof Drilled and tapped to specification, attach layout sheet. Dimensions are internal. XJDGCH N4 XJDFGCH N4 4 1/8 x 4 1/8 X 3 XJMCGCH N4 6 3/4 x 6 3/4 x 3 XJTGCH N4 XJTFGCH N4
More informationThreaded resistance thermometer Miniature design Model TR10-D
Temperature Threaded resistance thermometer Miniature design Model TR10-D WIKA data sheet TE 60.04 for further approvals see page 2 Applications Machine building, plant and vessel construction Propulsion
More informationTermination Board FC-GPCS-SAI16-PF. Features. Assembly. Function. Connection. SAI-1620m HART 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.
Features Assembly System board for Honeywell Safety Manager For 6-channel AI card SAI-60m For 6 modules Recommended module: HiC05 (AI) 4 V DC supply Hazardous area: pluggable screw terminals, blue Non-hazardous
More informationRT2Y Compact temperature switch intrinsic safety
ompact temperature switch intrinsic safety Main Features Excellent repeatability Fix dead band for control and alarm Resistant to accidental overtemperature Intrinsic safety Hazardous area 0, 1, 2 pplications
More informationEmergency Luminaire for Fluorescent Lamps Series EXLUX 6009
> As wall, ceiling and pendant light fitting or pole mounted light fitting > Version with 2 lamps: 18 W and 36 W > Central locking > All-pole disconnection via N/C switch when opening light fitting or
More informationPneumatic Control/Feedback
897 /Feedback Type 897 can be combined with... Compact design Integrated pilot valve with manual override Internal control air routing Bright LED position indicator Automatic end position adjustment Type
More informationInductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933
ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Rectangular, housing DSU35 Plastic, PP-GF30-VO Two outputs for monitoring the position of rotary actuators Mounting
More informationGrounding Monitoring Device Series 8485
www.stahl.de > Controlled electrostatic grounding of road tankers and rail cars during loading > Continuous monitoring of correct grounding > The object recognition prevents potential operator errors (with
More informationReferences. References. Rating (A) Référence
DIRECT OPERATION T O O R D E R EXTERNAL OPERATION picto_080_c_1_gb Switch body Direct Switch body + handle + Shaft + + OTHER ACCESSORIES External handle acces_128_a_1_cat acces_129_a_1_cat Direct handle
More informationUFD 5. Display for ALTOSONIC 5. Technical Datasheet. Configurable display for ALTOSONIC 5 Easy installation Durable design
UFD 5 Technical Datasheet Display for ALTOSONIC 5 Configurable display for ALTOSONIC 5 Easy installation Durable design KROHNE 04/2015-0.00000.00.00 CONTENTS UFD 5 1 Product features 3 1.1 Local display
More informationVariable Area Flowmeter DATASHEET
Variable Area Flowmeter DATASHEET JUNHO 0 Data sheet DS/A6/6EN Rev. I Models A600 & A600 Purgemaster SNAP-IN Small Flowmeter Long-term reliable performance flowmeters with low cost-of-ownership High strength
More informationLoads and Motor Switchgears
5 Loads and Motor Switchgears Motor Switches BLK Series Explosion-proof Motor Switches to -CENELEC -IEC -NEC Can be used in Zone 1 and Zone 2 Zone 21 and Zone 22 Class I, Zone 1 and Zone 2 Class I, Division
More informationRHE16. Compact Multifunction Coriolis Flow Meter Transmitter. Features. Applications. Benefits
RHE16 Compact Multifunction Coriolis Flow Meter Transmitter Features Extremely compact footprint ideal for embedding into small systems and machines Mount remotely or in compact form Low installation cost
More informationSensor boxes SRBC. Festo core product range Covers 80% of your automation tasks
Sensor boxes SRBC q/w Worldwide: Superb: Easy: Festo core product range Covers 80% of your automation tasks Always in stock Festo quality at an attractive price Reduces procurement and storing complexity
More information95100, 2/2 (stainless steel) Direct solenoid actuated poppet valves
9500, / (stainless steel) > > Port size: G/8, G/4, /4 NPT > > Working from 0 bar up > > Assembled free of oil and grease > > Suited for fine vacuum down to,33 0 - mbar > > For a.c. solenoid systems with
More information5 Fieldbus Technology
5 Fieldbus Technology Ex e / Ex i 10922E00 The s Ex e/ex i connect intrinsically safe Foundation Fieldbus H1 or Profibus PA field devices to a non-intrinsically safe / Ex e trunk. Up to four intrinsically
More informationInductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97
ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex-zone 20 for temperatures up to -25 C SIL2 acc. to IEC 61508 Rectangular, housing DSU35 Plastic, PP-GF30-VO Two outputs for monitoring the position
More informationMaterial pressure (bar) (Cv (US) kv x 1,2 Seat
00 / poppet valves electromagnetic actuated, directly controlled G /, / NPT or flanged with NAMUR Interface TÜV-approval based on IEC 6 08, DIN V Valves for safety systems up to SIL Solenoid valve also
More informationVALVES Inline 3/2-, 5/2- & 5/3 Spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, G 1/2, 1/2 NPT
975 Inline 3/-, 5/- & 5/3 Spool valves electromagnetic actuated, indirectly controlled G /, / NPT, G /, / NPT For single and double operated actuators Closed crossover design Add-on manual override Rectified
More informationPHOENIX CONTACT - 02/2008
Ex-i solenoid driver for Group IIC gases, loop-powered, pluggable INTERFACE Data Sheet 103211_00_en PHOENIX CONTACT - 02/2008 1 Description The solenoid driver PI-EX-SD-21-25 links a signaling device installed
More informationDigital Output Module 8-Channel Version for Zone 2 Series 9475/
> 8-channel digital output > Intrinsically safe outputs Ex ia > For Ex i solenoid valves and display elements > Line fault monitoring per channel > Diagnostics based on NE107 > Module can be replaced in
More informationThreaded thermocouple Miniature design Model TC10-D
Temperature Threaded thermocouple Miniature design Model TC10-D WIKA data sheet TE 65.04 for further approvals see page 2 Applications Machine building, plant and vessel construction Propulsion technology
More informationABB MEASUREMENT & ANALYTICS DATA SHEET. JDF200 Field Indicator
ABB MEASUREMENT & ANALYTICS DATA SHEET JDF200 Field Indicator 2 JD F 200 F IE LD IN D ICATO R DS /JDF200-E N RE V. G Measurement made easy Engineered solutions for all applications Digital LCD provides
More information97105 Inline 3/2, 5/2 & 5/3 way spool valves electromagnetic actuated, indirectly controlled G1/4, 1/4 NPT, G1/2, 1/2 NPT
70 Inline 3/, / & /3 way spool valves electromagnetic actuated, indirectly controlled G/, / NPT, G/, / NPT Main application: single and double operated actuators TÜV-approval based on type examination
More informationInductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933
ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1
More informationXLF. Ex d. - Zones 1, 2, 21, 22 - Obstruction warnings - Stroboscopic lights - Single or double fixtures - Low wind resistance
XLF - Zones 1, 2, 21, 22 - Obstruction warnings - Stroboscopic lights - Single or double fixtures - Low wind resistance Polycarbonate Fresnel lens Fixture without Fresnel lens Painted aluminium body E.2
More informationK1D004ACH cam switch - 4-pole A - for Ø 22 mm
Characteristics cam switch - 4-pole - 45-12 A - for Ø 22 mm Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing mode Cam
More informationResistance thermometer With spring-loaded tip Model TR55
Temperature Resistance thermometer With spring-loaded tip Model TR55 WIKA data sheet TE 60.55 for further approvals see page 2 Applications Bearing temperature measurement on: Pumps Gears Motors Special
More informationInstallation & Operation Manual
Via Enrico Fermi, 2 I-25015 Desenzano del Garda (BS) - Italy Phone: +39 030 7870787 Fax: +39 030 7870777 www.solexy.net BAF Intrinsically Safe Ethernet Coupler for signals operating in Hazardous Areas
More informationPosition Switches Series 8070
www.stahl.de > Enclosures of type of protection "Increased safety > Dimensions and characteristic values according to EN 50041 > Replaceable contact in flameproof enclosure > Positive opening contacts
More informationPneumatic Control/Feedback
897 /Feedback Type 897 can be combined with... Compact design Integrated pilot valve with manual override Internal control air routing Automatic end position adjustment With ATEX II cat. G/D and cat. D/G
More informationOperating and monitoring systems Operator Interface SERIES 300 Device platform EAGLE OS MT-316-TX
Operator Interface Operator Station 10" display, 800 x 600 pixels with resistive foil touch screen 12 function keys Zone 2, 22 and Division 2, optional GMP- compliant enclosure Data is transmitted via
More informationMagnetic field sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M12 x 1 Chrome-plated brass Rated operating distance 90 mm with DMR31-15-5 magnet DC 2-wire, nom.
More informationAssembly MAU. MUX 4 Channels 8 Channels Zone 1
Multi-Input/Output Device for Cabinet Installation Features Assembly For discrete inputs and outputs Installation in Zone 1/Div. 1, intrinsically safe Sensors in Zone 0/Div. 1 Connection to fieldbus acc.
More informationOperating and monitoring systems Operator Interface SERIES 300 Device platform EAGLE PM MT-336-FX
Operator Interface for panel mounting 15" display, 1024 x 768 pixels with resistive foil touch screen 8 function keys Zone 2, 22 und Division 2, can be installed in hazardous areas without additional enclosure
More information4 Remote I/O. Analog Output Module HART Ex i / I.S. Outputs, 8 Channels Series 9466/12
0 4 Remote I/O 8 channels for controlling HART control valves and positioners Intrinsically safe outputs Ex ia IIC Galvanic isolation between outputs and system Open-circuit and short-circuit monitoring
More informationK1F037MCH cam voltmeter switch - 3L and 3L-N A - for Ø 22 mm
Characteristics cam voltmeter switch - 3L and 3L-N - 60-12 A - for Ø 22 mm Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing
More informationSafety switches with separate actuator
Safety switches with separate actuator Selection diagram VF KEYD VF KEYD1 VF KEYD VF KEYD VF KEYD5 VF KEYD6 VF KEYD7 VF KEYD8 VF KEYD10 VF KEYD11 ACTUATORS FR FX FK FW 5 6 7 11 1 14 NC NC snap action snap
More informationDeltaV Bulk Power Supplies
DeltaV Distributed Control System Product Data Sheet DeltaV Bulk Power Supplies DeltaV 5 A, 10A, 20 A, 40 A Bulk Power Supplies. DeltaV 20 A, 40 A and 80 A Bulk Power Supply Redundancy Modules. Easy to
More informationOperating and monitoring systems Panel PC SERIES 400 Device platform EAGLE PM MT-436-TX
Panel PC for panel- mounting, quad core ATOM E3845 15" display, 1024 x 768 pixels with resistive foil touch screen 8 function keys Zone 2, 22 und Division 2, can be installed in hazardous areas without
More informationFlow Measurement SITRANS F M
Overview Mode of operation The flow measuring principle is based on araday s law of electromagnetic induction according to which the sensor converts the flow into an electrical voltage proportional to
More informationOperating Manual / IEC. Explosion-Proofed Junction Boxes, Polyester. Wallücker Bahndamm 7 DE Kirchlengern
Operating Manual / IEC Explosion-Proofed Junction Boxes, Polyester Wallücker Bahndamm 7 DE- 32278 Kirchlengern Tel.: +49 5223 49107-0 Fax: +49 5223 49107-28 info@multi-box.com www.multi-box.com Contents
More information2 Device description. 2 Device description 2.1 Function. 2.1 Function. 2.2 Intended use. 2.3 Device versions
2 Device description 2.1 Function 2 Device description 2.1 Function MICRO PANELs can be used as HMI devices or as integrated HMI/PLC devices. 2.2 Intended use MICRO PANELs are primarily used in machine
More informationAssembly. Front view. LED yellow/red: Status output Ι/ Fault signal Function. Switch Power Rail
Switch Amplifier KCD-SR-Ex.LB Features Assembly -channel isolated barrier V DC supply (Power Rail) Dry contact or NAMUR inputs Usable as signal splitter ( input and outputs) Relay contact output Fault
More informationDR7100 SERIES Supplementary instructions
DR700 SERIES Supplementary instructions Guided Radar (TDR) Level Instrument for 2-wire control systems Supplementary Instructions for ATEX applications AMETEK Drexelbrook - EDO -0-2, DR700-LM ATEX, Issue
More informationPLC-RSC- 24UC/21. Extract from the online catalog. Order No.:
Extract from the online catalog PLC-RSC- 24UC/21 Order No.: 2966184 The illustration shows the version PLC-RSC-24DC/21 PLC relay, consisting of base terminal block PLC-BSC.../21 with screw connection and
More informationDigital Output Module 8-Channel Version for Zone 1 Series 9475/
www.stahl.de > 8-channel digital output > Intrinsically safe outputs Ex ia > For Ex i solenoid valves and display elements > Additional Ex i control input for "Plant STOP" (acc. IEC61508 up to SIL2) >
More informationEFP SERIES FLAMEPROOF ELECTRICAL CONNECTORS FOR HAZARDOUS ENVIRONMENTS
EFP SERIES FLAMEPROOF ELECTRICAL CONNECTORS FOR HAZARDOUS ENVIRONMENTS Table of Contents EFP Introduction 4 Connector Features 5-7 Code Logic 8 Inline Plug w Threaded Entry Metric 9 Inline Plug w Mechanical
More information