Vacuum generator. Operating instructions b [ ]

Size: px
Start display at page:

Download "Vacuum generator. Operating instructions b [ ]"

Transcription

1 Vacuum generator OVEM- -LK en Operating instructions b [ ]

2 Original instructions OVEM- -LK-DE Identification of hazards and instructions on how to prevent them: Warning Hazards that can cause death or serious injuries Other symbols: Note Material damage or loss of function Recommendations, tips, references to other documentation Text designations: Activities that may be carried out in any order 1. Activities that should be carried out in the order stated General lists Result of an action/references to more detailed information 2 Festo OVEM- -LK b

3 1 About this document Product description Structure Characteristics Safety Use for intended purpose General safety information Range of applications and certifications Function and application Function overview Switching functions Valve control Air-saving function Monitoring and diagnostics Measured variables Teach function (Teach-In) Data storage (Data Storage) Block parameterisation Parameter description General instructions, IO-Link Identification parameters Process data (Process data) Smart Sensor profile parameters (Smart Sensor Profile Parameters) Device parameters (Device Parameters) Observation parameters (Observation Parameters) Diagnostics (Diagnosis) Device commands (Device Commands) Installation Mechanical Pneumatic Electrical Commissioning Commissioning vacuum generator Adjusting intensity of the ejection pulse Festo OVEM- -LK b English 3

4 8 Operation Operating manual override Restore factory settings Activating security code Error messages and fault clearance Status messages Diagnostic levels Error messages and error codes Malfunctions Disassembly Maintenance and care Technical data Appendix Graphic display and LCD displays Operating statuses and menu structure Meaning of symbols for representing the menu structure RUN mode SHOW mode Edit mode Teach mode Festo OVEM- -LK b English

5 1 About this document This document describes the use of the above mentioned product. All available documents for the product 2 Product description 2.1 Structure ab aa 7 aj Ejector pulse solenoid valve (Eject) 2 Vacuum solenoid valve 3 Mechanical manual override of the solenoid valves 4 Supply port (1) 5 Exhaust port / silencer (3) 6 Vacuum connection (2) 7 Housing with mounting holes Fig. 1 Control sections and connections 8 Slide for changing the filter element 9 Filter housing with inspection window aj Flow control screw for adjusting the ejector pulse aa Vacuum sensor with LCD display and operating keys Fig. 13 ab Electrical connection Festo OVEM- -LK b English 5

6 2.2 Characteristics Characteristic Code Meaning Vacuum generator OVEM Vacuum generator with vacuum solenoid valve ON/OFF and electric manual override Nominal width of laval nozzle mm mm mm mm mm Vacuum type -H High vacuum -L High suction volume Housing size / width -B 20 mm wide, ISO standard Pneumatic ports -QS All ports with QS push-in fittings -QO Supply / vacuum port with QS push-in fittings, exhaust port with open silencer -GN All ports with G female thread -GO Supply / vacuum port with G female thread, exhaust port with open silencer -PL Prepared for manifold rail, vacuum and exhaust port with QS push-in fittings -PO Prepared for manifold rail / vacuum port with QS push-in fittings, exhaust port with open silencer Normal position of the vacuum -OE NO, normally open (vacuum generation) with ejector pulse generator -CE NC, normally closed (no vacuum generation) with ejector pulse Electrical connection -N Plug M12 (5-pin) Vacuum sensor -LK IO-Link Alternative vacuum display - Bar -H InHg Tab. 1 Overview of variants 6 Festo OVEM- -LK b English

7 3 Safety 3.1 Use for intended purpose The vacuum generator type OVEM-...LK is designed for generating a vacuum. 3.2 General safety information The product may only be used in its original status without unauthorised modifications. Only use the product if it is in an excellent technical status. Use the product only inside buildings. Take into consideration the operating conditions at the location of use. The product is intended for use in industrial environments. The product can generate high frequency interference, which may make it necessary to implement interference suppression measures in residential areas. Observe the specifications on the product labelling. Comply with all applicable national and international regulations. Observe the local specifications for environmentally friendly disposal. Festo OVEM- -LK b English 7

8 3.3 Range of applications and certifications Note CE Declaration of Conformity In connection with the UL marking on the product, the information of this section is also applicable for compliance with the certification conditions of Underwriters Laboratories Inc. (UL) for the U.S.A. and Canada. UL approval information Product category code QUYX (USA) QUYX7 (Canada) File number E Considered standards UL C22.2 No UL mark Tab. 2 UL approval information Unit shall be supplied by a power source which complies with the requirements of a limited-energy circuit in accordance with IEC/EN/UL/CSA or a Limited Power Source (LPS) in accordance with IEC/EN/UL/CSA or IEC/EN/UL/CSA or a Class 2 circuit in accordance with NEC or CEC. 8 Festo OVEM- -LK b English

9 4 Function and application 4.1 Function overview The OVEM-LK is a vacuum nozzle with digital transmission of setpoint and actual value as well as diagnostics and parameterisation options. Communication takes place in the IO-Link mode. SIO mode is supported. IO-Link parameters and functions in accordance with Smart-Sensor profiles Chapter 5. 2 binary data channels for programming switching functions and switching behaviour. SIO mode: Local configuration via the operating keys. In the SIO mode, OVEM has the function of a 2P variant (1 switching input, 2 switching outputs). Functions: Control of the compressed air supply with 2 valve functions Chapter 4.3 Auto-Drop function: generation of an automatic eject pulse for accelerated vacuum purging and safe set-down Chapter 4.3 Air-saving function Chapter 4.4 Electrical and mechanical manual override Chapter 8.1 Monitoring of vacuum build-up through integrated pressure sensor. If the setpoint value is reached, or if it is not reached due to malfunctions (e.g. leakage, dropped workpiece), the vacuum generator emits an electrical signal and a status message. Prevention of vacuum purging through internal check valve if vacuum generation is interrupted. Data storage and expanded monitoring function. Festo OVEM- -LK b English 9

10 4.2 Switching functions The binary outputs can be configured via the switching functions. The switching status information is thereby made available at the electric port as a process value or binary signal. IO-Link mode: 3 BDC (binary data channels), bit 0: BDC1 or BDC2, bit 1: BDC3 Chapter 5.3 SIO mode: 2 switching outputs Out A and Out B The switching logic of the binary outputs can be configured as normally open (NO) or normally closed (NC). The switching mode of the binary outputs can be determined as threshold value or window comparator. Threshold value comparator Normally open (NO) Normally closed (NC) Switching function 1 Switchpoint (SP1) Teach mode 1) : 2 Teach-in points (TP1, TP2) SP1 = ½ (TP1+TP2) OUT 1 0 1) TP1 = smaller pressure value, TP2= larger pressure value, independent of the Teach sequence Tab. 3 Threshold value comparator: setting of switchpoint SP1 and hysteresis HY HY TP1 SP1 TP2 p OUT 1 0 HY TP1 SP1 TP2 p Window comparator Normally open (NO) Normally closed (NC) Switching function: OUT OUT 2 switchpoints (SP1, SP2) 1 HY HY 1 HY HY Teach mode 1) : 2 Teach-in points (TP1, TP2) 0 TP1=SP1 TP2=SP2 p 0 TP1=SP2 TP2=SP2 p 1) TP1 = smaller value, TP2 = larger value, independent of the Teach sequence Tab. 4 Window comparator: setting of switchpoints SP1, SP2 and hysteresis HY 10 Festo OVEM- -LK b English

11 4.3 Valve control Depending on the input signal, the vacuum solenoid valve or the ejector pulse solenoid valve is controlled. IO-Link mode: 2 BCS (binary control signals), bit 0: BDC1, bit 1: BDC2 Chapter 5.3 SIO mode: 1 switching input DI1 (Z BCS1). Switching input positive switching (PNP) Auto-drop function: The ejector pulse is generated after the signal change Suction (BCS1). The pulse length can be set through the parameter Auto-Drop time Tab. 11. Valve function OVEM-...-CE Auto-drop active Auto-drop inactive Auto-Drop t ab Auto-Drop t ab 5 Valve function OVEM-...-OE Auto-drop active Auto-drop inactive Auto-Drop t ab Auto-Drop t ab 5 1 Control signal BCS1 / switching input DI1 2 Control signal BCS2 3 Vacuum solenoid valve switching status Fig. 2 Valve control switching behaviour 4 Ejector pulse solenoid valve switching status 5 Vacuum connection (2) t ab Duration of ejector pulse Festo OVEM- -LK b English 11

12 4.4 Air-saving function The air-saving function reduces air consumption during the evacuation phase. 50 mbar (fixed) t BCS1/DI1 BDC1 t t 1 Hysteresis (HY) 2 Threshold value Switch off suction = switchpoint (SP1) 3 Threshold value Switch on suction 4 Reset point (RSP1) Fig. 3 Mode of operation of the air-saving function If the pressure value has reached the switchpoint SP1 2, vacuum generation is deactivated. A an internal check valve prevents the reduction of the vacuum. Vacuum can still be reduced slowly due to leakage in the overall system (e.g. due to rough workpiece surfaces). To reduce energy consumption, vacuum generation is not switched on until the lower threshold value 3 is fallen below. This procedure runs as long as the control signal is present at BCS1/DI1. The air saving function is activated in the factory. 4.5 Monitoring and diagnostics The vacuum generator has monitoring functions that permit early detection of malfunctions or errors in ongoing operation. Monitoring of process parameters (pressure value at the vacuum connection, limit values of binary data channels, evacuation time t E, air supply time t B ). Error detection and diagnostic messages Chapter 9 The monitoring functions are activated at the factory (except for monitoring of the evacuation and air supply times). The time monitoring can be activated through setting of the limit values SP1 (evacuation time) and SP2 (air supply time) in BDC4 Tab. 10. The switching status information of the BDC4 is not included in the process input data (Process data IN). 12 Festo OVEM- -LK b English

13 4.6 Measured variables Pressure value (vacuum) The pressure value (vacuum) is continuously measured between the vacuum connection and filter. The minimum and maximum measured pressure values are saved. If the operating voltage of the vacuum generator is switched off, these values are reset. Cycle time A cycle covers the time from the start of evacuation through ejection to the start of the new evacuation. Evacuation time and air supply time The evacuation time t E is measured from the start of evacuation until reaching of the switchpoint SP1 by BDC1 or BDC2. The air supply time t B is measured from the start of air supply to the time at which the pressure value (vacuum) falls below 50 mbar. p Cycle time 1 50 mbar 0 2 t t E Transport time t B Return time BCS1/DI BDC1 or BDC2 / Out A Vacuum valve Ejector pulse valve 1 Switchpoint SP1 (BDC1 or BDC2) t E 2 Reset point RSP1 (BDC1 or BDC2) t B Fig. 4 Clock cycle (example for Out A (Air-save)) Evacuation time Air supply time Festo OVEM- -LK b English 13

14 4.7 Teach function (Teach-In) The Teach function permits configuring the switchpoints and time monitoring during run time. Static Teach-In Depending on the teach command, one switchpoint (SP) or 2 switchpoints (SP1, SP2) are determined from 2 teach-in points. The switchpoints are determined statically, that is, the measurement value remains constant during the entire Teach-In procedure. During execution of the Teach-In procedure, the air save function is deactivated for the duration of the procedure. Teach commands Tab. 16 Simplified Teach commands BDCx Start (Teach Start), BDCx Stop (Teach Stop) can be used independently of the switching function. The sequence of the teach-in points must be taken into account. For all commands, first the desired channel must be selected. Dynamic Teach-In Setpoint values are calculated within the Teach-In procedure from a time period. The procedure is used for determination of evacuation and air supply times Fig. 5. After the start of the Teach-In, the time t E and t B is measured at each cycle. With multiple cycle times, the times are averaged. After the stop of the Teach-In, a function reserve of 100 % is added to the averaged values. p SP1 50 mbar Teach Start t E1 1 tb1 2 t E2 t B2 Teach Stop t Vacuum valve t 1 Transport time 2 Return time Fig. 5 Dynamic mode of operation Teach-In 3 Cycle time 1 4 Cycle time 2 5 Cycle time N 14 Festo OVEM- -LK b English

15 4.8 Data storage (Data Storage) The data storage mechanism (DS) permits consistent and updated saving of device parameters to higher levels, such as PLC programs or fieldbuses. Changes of the parameters are messaged by the vacuum generator to the IO-Link Master, which then fetches the parameter, saves it in a higher-level system and makes it available to the new device if the vacuum generator is replaced. Parameters that can be saved Chapter 5 The data storage mechanism is supported at the device, but is administered by the application (IO-Link master). 4.9 Block parameterisation Block parameterisation permits uniform access to parameters over multiple indexes or subindexes as well as transfer of entire parameter sets. Transfer of block parameters through start and end commands Tab. 16 During transfer, parameter changes (e.g. through Teach-In) are blocked. In case of an invalid parameter set, the changed parameters are discarded and the previous parameter set is reactivated. Festo OVEM- -LK b English 15

16 5 Parameter description Note Related device description file (IODD) For detailed information on the IO-Link specification and for the Smart Sensor Profil General instructions, IO-Link Characteristic Specification Protocol version Device V1.1 Profile Smart Sensor Profile Function classes Tab. 10 Communication mode COM2 (38.4 kbaud) Port class A Process data width IN 2 bytes Tab. 8 Process data content IN 2 bit BDC (pressure monitoring), 14 bit PDV (pressure measurement value) Process data width OUT 1 byte Tab. 9 Process data content OUT 1 bit (vacuum ON/OFF), 1 bit (ejector pulse ON/OFF) Block parameterisation Supported Data memory required 0.5 KB Minimum cycle time 3.5 ms SIO mode support Yes Tab. 5 General instructions (general IO-Link specification) 5.2 Identification parameters Identification direct parameters (Identification Direct Parameters) Index Name Value Description Information 0x07 VendorID1 (MSB) 0x01 Manufacturer identification R 0x08 VendorID2 (LSB) 0x4D 0x09 DeviceID1 (MSB) 0x00 Device identification 0x0A DeviceID2 0x00 0x0B DeviceID3 (LSB) 3C Device variant OVEM-...-H-...-OE 3D Device variant OVEM-...-L-...-OE 3E Device variant OVEM-...-H-...-CE 3F Device variant OVEM-...-L-...-CE 1) R = read Tab. 6 Identification direct parameters (Identification Direct Parameters) 16 Festo OVEM- -LK b English

17 Identification device parameters (Identification Device Parameters) Index Subindex Name Value Description Information 0x Vendor Name Festo AG & Co. KG Manufacturer name R 0x Vendor Text Includes additional information 0x Product Name e.g. OVEM-05-H-B-QO- CE-N-LK Complete order code of the product 0x Product ID e.g. OVEM-H-CE Device variant/type designation 0x Product Text Vacuum generator Device characteristic 0x Serial Number XXXXXXXXXXX Product key 0x Hardware Revision 0x Firmware Revision 0x Application SpecificTag e.g REV00101 e.g. V Part number and revision status of the product Firmware version of the device *** Application-specific marking, can serve as functional identification. 1) R = read, R/W = read and write, FR = factory reset (Factory Reset), DS = data storage (Data Storage) possible Tab. 7 Identification device parameters (Identification Device Parameters) R/W FR DS 5.3 Process data (Process data) Process input data (Process data IN) Bit 15 (MSB) 2 (LSB) 1 0 Process data 1) Process Data Variable (PDV) BDC3 BDC1/BDC2 2) Data content 1) Pressure Value 3) Out B Out A (Air-save) / Out A 1) R = read 2) Assignment of the BDC is dependent on the parameter Air-saving function: Air-save ON = BDC1, Air-save OFF = BDC2 3) Current pressure value (pressure value) standardised and scaled to 14 bit. Formula: p2 = pressure value*(1000 mbar/16383) Tab. 8 Process input data (Process data IN) Process output data (Process data OUT) Bit Process Data 1) Reserved BCS2 2) BCS1 3) Data content 1) Reserved Drop Vacuum 1) W = write, no data storage (Data Storage) 2) Values: BCS2 = 0: ejector pulse solenoid valve not switched, BCS2 = 1: ejector pulse solenoid valve switched 3) Values: BCS1 = 0: vacuum solenoid valve not switched, BCS1 = 1: vacuum solenoid valve switched Tab. 9 Process output data (Process data OUT) Festo OVEM- -LK b English 17

18 5.4 Smart Sensor profile parameters (Smart Sensor Profile Parameters) Index Name Value Description Length (byte) 0x000D 0 Profile List of profile identifiers 12 R 1 Characteristic 0x0001 Smart Sensor Profile 2 2 0x8000 Device Identifikation 2 3 0x8001 Binary data channel (BDC) 2 4 0x8002 Process data variable (PDV) 2 5 0x8003 Diagnostics 2 6 0x8004 Teach channel 2 0x000E 0 PD Input Data structure of the process input data 6 1 Descriptor 0x BDC1, BDC x020E02 Process data variable (pressure) 3 0x000F 0 PD Output Data structure of the process output data 3 1 Descriptor 0x BCS1, BCS2 3 0x003A 0 Teach-In channel 0x003B 0 Teach-In Status 1 Teach flag TP2 for SP2 2 Teach flag TP1 for SP2 3 Teach flag TP2 for SP1 4 Teach flag TP1 for SP1 0 Standard value; BDC1 with activated air-saving function (Air-save = ON); BDC2 with deactivated air-saving function (Air-save = OFF) 1 BDC1 (Out A Air-save) 2 BDC2 (Out A) 3 BDC3 (Out B) 4 BDC4 (Monitoring of evacuation time/air supply time) 0 Current status of the activated Teach-In channel 0 Teach point TP2 for SP2 not taken over 1 Teach point TP2 for SP2 taken over 0 Teach point TP1 for SP2 not taken over 1 Teach point TP1 for SP2 taken over 0 Teach point TP2 for SP1 not taken over 1 Teach point TP2 for SP1 taken over 0 Teach point TP1 for SP1 not taken over 1 Teach point TP1 for SP1 taken over 5 Teach state Current status of the Teach-In 1) R = read, W = write, R/W = read and write, DR = device restart (Device Reset) DS = data storage (Data Storage) possible Subindex Information 1) 1 R/W DR DS 1 R DR 18 Festo OVEM- -LK b English

19 Index Name Value Description Length (byte) Subindex Information 1) BDC1 - Out A (Air-save) air-saving function (Air-saving function) 0x003C 0 Setpoint SP (0-1 bar) Lower switchpoint Standard values: OVEM-...-L: 6553 (-0.4 bar) OVEM-...-H: (-0.7 bar) 1 Setpoint SP2 0 Upper switchpoint Standard value: 0 0x003D 1 Switchpoint logic 2 Switchpoint mode 3 Switchpoint hysteresis (0-0.9 bar) BDC2 - Out A 0x003E 0 Setpoint SP (0-1 bar) 1 Setpoint SP (0-1 bar) 0x003F 1 Switchpoint logic 2 Switchpoint mode 3 Switchpoint hysteresis (0-0.9 bar) Switchpoint logic 1 0 NO (Standard) 1 Switchpoint logic NC Switchpoint mode 1 1 Single point mode (Standard) 2 Window mode Hysteresis value Standard value: 4096 (0.25 bar) Lower switchpoint Standard values: OVEM-...-L: 6553 (-0.4 bar) OVEM-...-H: (-0.7 bar) Upper switchpoint Standard values: OVEM-...-L: (-0.67 bar) OVEM-...-H: (-0.97 bar) Switchpoint logic 1 0 NO (Standard) 1 NC Switchpoint mode 1 1 Single point mode (Standard) 2 Window mode Hysteresis value Standard value: OVEM-...-L: 1638 (0.1 bar) OVEM-...-H: 4096 (0.25 bar) 1) R/W = read and write, FR = restore factory settings (Factory Reset), DS = data storage (Data Storage) possible 2 R/W FR DS R/W FR DS 2 2 Festo OVEM- -LK b English 19

20 Index Name Value Description Length (byte) BDC3 - Out B 0x Setpoint SP (0-1 bar) 1 Setpoint SP (0-1 bar) 0x Switchpoint logic 2 Switchpoint mode 3 Switchpoint hysteresis 0x Setpoint SP1 (evacuation timeout) 1 Setpoint SP2 (ventilation timeout) (0-0.9 bar) Lower switchpoint Standard values: OVEM-...-L: 3227 (-0.2 bar) OVEM-...-H: (-0.5 bar) Upper switchpoint Standard values: OVEM-...-L: 6717 (-0.41 bar) OVEM-...-H: (-0.71 bar) Switchpoint logic 1 0 NO (Standard) 1 NC Switchpoint mode 1 1 Single point mode (Standard) 2 Window mode Hysteresis value Standard values: OVEM-...-L: 1638 (0.1 bar) OVEM-...-H: 3227 (0.2 bar) Subindex Information 1) 2 R/W FR DS BDC4 - Evacuation time t E and air supply time t B (Time monitoring evacuation/ventilation) Evacuation time limit value t 2) E ( ms) Standard: 0 0x Switchpoint logic 0x Switchpoint mode 3 Switchpoint hysteresis ( ms) Air supply time limit value t B 2) Standard: 0 Switchpoint logic of the 1 diagnostic output 1/2 0 NO (Standard) 1 NC 128 Switchpoint mode BDC4 3) 1 Standard value: Hysteresis value R/W FR DS 1) R/W = read and write, FR = restore factory settings (Factory Reset), DS = data storage (Data Storage) possible 2) Time = 2.5 ms * Value 3) Value = 128: vendor specific. Five measurements are recorded; if the limit is exceeded 3 times, an event is created as a warning Tab. 10 Smart Sensor Profile Parameter - (Smart Sensor Profile Parameters) 2 20 Festo OVEM- -LK b English

21 5.5 Device parameters (Device Parameters) Index Subindex Name Bit Value Description Information 1) 0x000C 0 Device Access Lock 0x01E2 0 Air-saving function 0x011F 0 Pin-2 configuration 0x Pin-2 switchpoint logic Controls the blocking function of the device 0 0 (Write) access to parameters unblocked 1 (Write) access to parameters blocked 1 0 Data storage (DS) unblocked 1 Data storage (DS) blocked 2 0 Local parameterisation unblocked 1 Local parameterisation blocked 3 0 Local user interface unblocked 1 Local user interface blocked 0 Air-saving function is deactivated. Switching status of BDC2 (Out A) is output in Process data IN. 1 Air saving function is activated (standard). Switching status of BDC1 (Out A Air-save) is output to Process data IN. 1 Switching status of BDC3 is output to pin 2 (standard) 5 Switching status of the diagnostic message channel 1 (di1) is output to pin 2. 6 Switching status of the diagnostic message channel 2 (di2) is output to pin 2. 0 Switchpoint logic of pin 2 - NO (standard) 1 Switchpoint logic of pin 2 - NC 0x01EA 0 Lock Code 0 Local parameterisation is enabled (standard) 1 Local parameterisation is blocked through security code (max. 9999) 0x Auto-Drop time 0 Auto-Drop inactive (40 ms 10 s) Length of the automatic ejector pulse 2) ; Standard: 80 (200 ms) R/W FR DS 1) R/W = read and write, FR = restore factory settings (Factory Reset), DS = data storage (Data Storage) possible 2) Length of the automatic ejector pulse = 2.5 ms * Value Tab. 11 Device parameters (Device Parameters) Festo OVEM- -LK b English 21

22 5.6 Observation parameters (Observation Parameters) Index Subindex Name Value Description Information 1) Process data (Process data) 0x Process data input Includes the last valid process input data; standard: 0 1 Process data input BDC3 status 0 BDC3 inactive 1 BDC3 active 2 Process data input BDC1/BDC2 status 2) 0 BDC1 or BDC2 inactive 1 BDC1 or BDC2 active 3 Process data input Pressure value (0 1 bar) Last valid pressure value 0x Process data output 0 3 Includes the last valid process output data; standard: 0 2 Process data output BCS1 3 Process data output BCS2 Run-time parameters (Run Time Parameters) 0x Minimum process value 0x Maximum process value 0 Vacuum solenoid valve not switched 1 Vacuum solenoid valve switched 0 Ejector pulse solenoid valve not switched 1 Ejector pulse solenoid valve switched (0 mbar 1 bar) (0 mbar 1 bar) 0x Last process value (0 mbar 1 bar) 0x Minimum evacuation time 0x Maximum evacuation time (0 10 s) (0 10 s) 0x Last evacuation time (0 10 s) 0x Minimum ventilation time (0 10 s) Minimum measured pressure value as process value Maximum measured pressure value as process value Last measured pressure value as process value Minimum measured evacuation time t 3) E Maximum measured evacuation time t 3) E Last measured evacuation time t 3) E Minimum measured air supply time t 3) B R DR R DR 1) R = read, DR = device restart (Device Reset) 2) With activated air-saving function (Air-saving function = ON), the status of the BDC1 is output With deactivated air-saving function (Air-saving function = OFF), the status of the BDC2 is output 3) Time = 2.5 ms * Value 22 Festo OVEM- -LK b English

23 0x Maximum ventilation time (0 10 s) 0x Last ventilation time (0 10 s) Description Maximum measured air supply time t 3) B Last measured air supply time t 3) B Information 1) R DR 1) R = read, DR = device restart (Device Reset) 2) With activated air-saving function (Air-saving function = ON), the status of the BDC1 is output With deactivated air-saving function (Air-saving function = OFF), the status of the BDC2 is output 3) Time = 2.5 ms * Value Tab. 12 Observation parameters (Observation Parameters) 5.7 Diagnostics (Diagnosis) General diagnostic parameters Index Index Subindex Name Value Run-time parameters (Run Time Parameters) Subindex Name Value Description Information 1) 0x Error count 0 Number of errors (device status 3) since the device was switched on or reset 0x Device status 0 Device is working correctly (standard) 1 Maintenance required 2 Device outside specification 3 4 Function test or failure 0x Detailed device 0 Detailed device status Tab. 14 status 0x Supply voltage 7864 (24 V) Current power supply to the device as process value R DR 1) R = read, DR = device restart (Device Reset) 2) Voltage value = 50 V * value/16283 Tab. 13 General diagnostic parameters (Diagnosis) Festo OVEM- -LK b English 23

24 Detailed device status (Detailed Device Status, Event Codes) Name Event Code Description Subindex Information 1) 1 Device failure 0x5000 Hardware errors in the device R 2 Supply fault 0x5100 General errors in power supply DR F 3 Temperature over-run 0x4210 Device temperature exceeded R DR W 4 Pin-4 overload 0x1815 Overload at plug, pin 4 5 Pin-2 overload 0x1816 Overload at plug pin 2 6 Evacuation solenoid failure 7 Ventilation solenoid failure 8 Evacuation time over-run 9 Evacuation time explicit over-run 10 Ventilation time over-run 11 Ventilation time explicit over-run 12 Air-save max. frequency 13 Vacuum low level 14 Supply voltage over-run 15 Supply voltage under-run 0x1820 0x1821 0x1822 0x1823 0x1824 0x1825 0x1826 0x1827 0x5110 0x5111 Vacuum solenoid valve defective Solenoid valve, ejector pulse defective Evacuation time t E exceeded 3 times out of 5 measurements Evacuation time t E exceeded 3 times out of 5 measurements by at least twice the value Evacuation time t B exceeded 3 times out of 5 measurements Evacuation time t B exceeded 3 times out of 5 measurements by at least twice the value Max. switching frequency of the air-saving function exceeded, air-saving function deactivated SP1 at BDC1/BDC2 not reached after 10 s RSP1 fallen below at BDC1/BDC2 SP2 at BDC2 exceeded Supply voltage too high Supply voltage too low 16 Air-save failure 0x182A BDC1 outside the min. limit value, air-save function deactivated 1) R = read, DR = device restart (Device Reset) F = event type fault, W = event type warning Tab. 14 Index 0x0025: detailed device status (Detailed Device Status, Event Codes) 24 Festo OVEM- -LK b English

25 5.8 Device commands (Device Commands) System commands (System Commands) Index Subindex Name Description Information 0x System Command System command, is sent with a command code Tab. 16 W 1) W = write Tab. 15 System commands (System Commands) Command Name Description code (hex) 0x00 Reserved 0x01 ParamUploadStart Start of the parameter upload 0x02 ParamUploadEnd Stopping of the parameter upload 0x03 ParamDownloadStart Start of the parameter download 0x04 ParamDownloadEnd Stopping of the parameter download 0x05 ParamDownloadStore Complete parameterisation and start data storage 0x06 ParamBreak Termination of all Param commands 0x41 SP1 Single Value Teach Determines the teachpoint TP1 for the switching point SP1 for the respective BDCx in the window comparator 0x42 SP2 Single Value Teach Determines the teachpoint TP1 for the switching point SP2 for the respective BDCx in the window comparator 0x43 SP1 Two Value Teach TP1 Determines the teachpoint TP1 for the switching point SP1 for the respective BDCx in the threshold comparator 0x44 SP1 Two Value Teach TP2 Determines the teachpoint TP2 for the switching point SP1 for the respective BDCx in the threshold comparator 0x4B BDCx Teach Start Starting of the Teach-In sequency for the respective BDCx 0x4C BDCx Teach Stop Stopping the Teach-In sequence for the respective BDCx 0x4F Teach Cancel Termination of a Teach-In smaller sequences 0x80 Device Reset Warm start of the device, resetting of the run-time parameters 0x82 Restore factory settings Resetting the configuration and the parameter to the original condition (default values) Tab. 16 Command code (Command Code) Festo OVEM- -LK b English 25

26 6 Installation 6.1 Mechanical Note An unfavourable mounting position can impair the function of the product. Install the vacuum generator so that no condensation from the compressed air lines can gather in the device. Install the vacuum generator so that it cannot be heated above the maximum permissible operating temperature (plan for convection possibilities). Install the vacuum generator so that the exhaust can flow without hindrance. Direct mounting M5 / M4 Tab. 17 Max. 2.5 Nm M3 Max. 0.8 Nm Fig. 6 Direct mounting on the side Fig. 7 Direct mounting on the back OVEM OVEM / -07/ -10 OVEM / -20 Mounting screws M5 M4 Tab. 17 Size of the mounting screws with direct mounting on the side 26 Festo OVEM- -LK b English

27 Mounting on H-rail H-rail mounting accessory M3 Max. 0.8 Nm Mount H-rail mounting Hang OVEM with H-rail mounting in the H-rail and press in the direction of the arrow Secure with screw 1 to the H-rail. Fig. 8 H-rail mounting Mounting via mounting bracket Accessories for mounting bracket M5 / M4 Tab. 17 Max. 2.5 Nm Fig. 9 Mounting with mounting bracket Mounting on supply manifold Mounting is possible on a supply manifold with a maximum of 8 places (Assembly instructions OABM-P Festo OVEM- -LK b English 27

28 6.2 Pneumatic OVEM-...-CE Circuit symbol OVEM-...-OE Circuit symbol OVEM-...-QO-CE OVEM-...-GO-CE OVEM-...-QO-OE OVEM-...-GO-OE OVEM-...-QS-CE OVEM-...-GN-CE OVEM-...-QS-OE OVEM-...-GN-OE Tab. 18 Circuit symbols, pneumatic OVEM GN GO GN GO GN GO GN GO GN GO Tubing length [m] < 0.5 < 2 < 0.5 < 2 < 0.5 < 2 < 0.5 < 2 < 0.5 < 2 Min. internal diameter of tubing Supply port [mm] Vacuum port [mm] Exhaust port [mm] Tab. 19 Minimum inside diameter of the connection tubes for connections with G-female thread Notes on the pneumatic connection Maximum permissible tube length 2 m. OVEM-...-GN/GO: Pay attention to the minimum inside diameter of the connection tubes Tab. 19. Do not seal exhaust port. OVEM /-10/-14/-20: If necessary, lengthen silencers with a silencer extension (accessories Recommendation: Use tubes of type PUN from Festo 28 Festo OVEM- -LK b English

29 6.3 Electrical Warning Electric voltage. Risk of injuries caused by electric shock, damage to the machine and system. For the electrical power supply, use only PELV circuits in accordance with IEC /EN Use only voltage sources that ensure a reliable electric separation from the mains network in accordance with IEC /EN Observe the requirements of IEC /EN for PELV circuits. Connect vacuum generator to the IO-Link master. 5-pin plug, M12x1, Porttyp A Maximum tightening torque plug connector M12: 0.5 Nm Maximum permissible cable length: 20 m Plug connector Pin Wire colour 1) Function M12x1 1 1 Brown (BN) L V 2 White (WH) DO2 Digital output Out B (PNP) Blue (BU) L- 0 V 4 Black (BK) C/Q IO-Link communication or 3 5 digital output Out A (PNP) 2) 5 Grey (GY) DI1 Not assigned or digital input (PNP) 3) 1) When using the connecting cable in accessories 2) After a fallback or in the SIO-mode, this pin has the configuration of a digital switching output 3) This pin is not assigned in the IO-Link mode. After a fallback or in the SIO-mode, this pin has the configuration of a digital input Tab. 20 Festo OVEM- -LK b English 29

30 7 Commissioning Note Commissioning should only be conducted by qualified personnel. 7.1 Commissioning vacuum generator At initial commissioning, the vacuum generator is placed in operation with the factory settings Tab. 21. Requirement Vacuum generator is fully mounted and connected Chapter 6. Check operating conditions Check the operating conditions and limit values Technical data. Place vacuum generator OVEM-...-OE in operation 1. Apply operating pressure to compressed air supply port (1). Underpressure is generated at the vacuum connection (2). 2. Switch on the operating voltage. The current pressure value is displayed. The vacuum generator is ready for operation. Place vacuum generator OVEM-...-CE in operation 1. Apply operating pressure to compressed air supply port (1). 2. Switch on the operating voltage. 3. In the IO-Link mode: Activate suction (or in the SIO mode: Apply input signal to pin 5). Underpressure is generated at the vacuum connection (2). The current pressure value is displayed. The vacuum generator is ready for operation. Changing of the operating pressure changes the strength of the underpressure at the vacuum connection. As a result, the vacuum can be set at the suction gripper. Functions and parameters can be determined: in IO-Link operation Chapter 5 manually on the device Chapter through Teach-In Chapter Festo OVEM- -LK b English

31 7.2 Adjusting intensity of the ejection pulse Fig. 10 Screw in flow control screw Requirement Vacuum generator is in operation. Adjust ejector pulse 1. Completely screw in flow control screw for adjusting the ejector pulse. 2. Switch on vacuum generation. The maximum possible underpressure is generated at the vacuum connection (2). 3. Switch off vacuum generation. 4. Switch on solenoid valve ejector pulse. No ejector pulse is generated. 5. Switch off solenoid valve ejector pulse. 6. Unscrew the flow control screw for adjusting the ejector pulse somewhat. 7. Switch on solenoid valve ejector pulse. An ejector pulse is generated. 8. Repeat work steps 1. to 7. until the necessary intensity of the ejector pulse is set. Note When large suction grippers are used, a vacuum independent of the device can be built up for physical reasons. This might mean that the workpiece does not detach from the suction gripper, even if the ejector pulse is set to a sufficiently long duration. Festo OVEM- -LK b English 31

32 8 Operation Communication takes place in the IO-Link mode. SIO mode is supported. Parameter description IO-Link mode Chapter 5 Meaning of the displays Chapter 13.1 Menu structure in the SIO mode Chapter Operating manual override Both solenoid valves can be manually switched with the manual override. Mechanical manual override 1. Press in the stem of the manual override with a blunt pin. The solenoid valve switches. 2. Remove the pin. The stem of the manual override automatically returns. The solenoid valve reverts to the basic position. Fig. 11 Electrical manual override The electrical manual override is actuated with the operating keys (Sub-menu FORC Fig. 15). 8.2 Restore factory settings Through resetting of the factory settings, the parameters, configuration and security code are reset to the condition at shipment Tab. 21. The current settings are lost. The parameters and configurations that can be restored are marked in the parameter description with FR (Factory Reset) Chapter 5. Reset through IO-Link command Execute system command Restore factory settings Tab. 16. Resetting with operating buttons on the device 1. Switch off the operating voltage. 2. Simultaneously press and hold down A-key + B-key + Edit button. 3. Switch on the operating voltage. 4. Release the A-key + B-key + Edit button. LCD display shows [CLEA]. The factory settings are restored. 32 Festo OVEM- -LK b English

33 Factory settings Parameter OVEM-...-H OVEM-...-L Switching mode of the electrical output Threshold value comparator Switching logic of the electrical output NO (Normally Open) Air-saving function Active Security code OFF BDC1 - Out A (Air-save) SP1-0.7 bar -0.4 bar Hysteresis 0.25 bar BDC2 - Out A SP1-0.7 bar -0.4 bar SP bar bar Hysteresis 0.25 bar 0.1 bar BDC3 - Out B SP1-0.5 bar -0.2 bar SP bar bar Hysteresis 0.2 bar 0.1 bar Duration of ejector pulse 200 ms Tab. 21 Factory settings 8.3 Activating security code A security code can be established and activated to prevent changes to parameter settings and configurations from being made locally by unauthorised persons. The security code protects against entries made locally through the operating keys on the device. IO-Link parameterisation is not affected. Factory setting OFF. The security code is reset when factory settings are restored. For entry and activation in the Edit mode Chapter Festo OVEM- -LK b English 33

34 9 Error messages and fault clearance The diagnostic messages are shown as event code in the IO-Link mode and as error code in the display. In addition, diagnostic messages can also be signaled through the switching output Out B. In the IO-Link mode, a variety of diagnostic and monitoring functions are available. 9.1 Status messages Status Type Definition 0 Device is OK 1 Notification Check required 2 Warning Outside the specification 3 Error Malfunction Tab. 22 Status messages diagnostics IO-Link 9.2 Diagnostic levels There are 4 diagnostic levels. The red background illumination of the display lights up for messages of the diagnostic levels 1 to 3. As an additional diagnostic option, the vacuum generator has a diagnostic message channel. This can be set with the configuration of pin 2 Chapter Configuration options for pin 2: definition as switching output (In A1) diagnostic message channel 1 (di1) diagnostic message channel 2 (di2) The diagnostic message channel can be configured as normally open (NO) or normally closed (NC). Diagnostic level Diagnostic message channel Description 0 No message Device is OK. 1 Logical channel di1 active 2 Logical channel di1 or di2 is active 3 Logical channel di1 or di2 is active No restriction in function yet, but operating parameters are worsening Function still ensured, but with restrictions (e.g. higher power consumption). Emergency operation, maintenance urgently required. Function is no longer assured. All controllable outputs of the device are inactive. Tab. 23 Diagnostic levels for switching output Out B and display 34 Festo OVEM- -LK b English

35 9.3 Error messages and error codes Display Eventcode IO-Link D 1) S 2) Description Remedy Er1 0x Hardware errors in the device Replace device Er17 0x Supply voltage is too high or too Check power supply low (error) Er20 0x Permissible device temperature exceeded Keep device away from heat sources Er21 0x Short-circuit Out A Check output for overload Er22 0x Short-circuit Out B Er32 0x Vacuum solenoid valve does not switch or does not switch correctly Er33 0x Ejector pulse solenoid valve does not switch or does not switch correctly Er34 0x Evacuation time exceeded in 3 of 5 cycles (warning) Er35 0x Evacuation time exceeded by a factor of two in 3 of 5 cycles Er36 0x Air supply time exceeded in 3 of 5 cycles (warning) Er37 0x Air supply time exceeded by a factor of two in 3 of 5 cycles Er38 0x Switching frequency of the air saving function > 1 Hz (warning) [Option] flashing 0x182A 0 2 Air-save function deactivated because outside the limit value Er39 0x SP1 for Out A not reached after 10 s Er40 0x Supply voltage too high (warning) Er41 0x Supply voltage too low (warning) 1) Diagnostic levels display 2) Status IO-Link Tab. 24 Error messages, error codes, diagnostic levels and error description Check installation Press mechanical manual override several times Check power supply Replace device Check for leakage Check parameterisation SP1 of BDC4 Check for leakage Lengthen air supply time Check throttle setting Check parameterisation SP2 of BDC4 Check for leakage Check parameterisation BDC1 Check for leakage Check parameterisation BDC1 Check for leakage Check parameterisation BDC1 / BDC2 Check power supply Festo OVEM- -LK b English 35

36 9.4 Malfunctions Malfunction Possible cause Remedy Workpiece does not detach from the suction gripper Switching output does not react in accordance with the settings Device-independent vacuum between workpiece and suction gripper, ejector pulse not activated or sufficiently dimensioned Activate ejector pulse when lifting the suction gripper Increase the duration and intensity of the ejector pulse Tubing dimensioned incorrectly Replace tubing (tubing dimensions Chapter 6.2) Flow control screw closed Open the flow control screw Short circuit or overload at the Eliminate short circuit or overload output Device defective Replace device No display Operating voltage faulty Apply permissible operating voltage Chapter 6.3 Electrical connections swapped Connect device correctly Chapter 6.3 Device defective Replace device Incomplete display Display defective Replace device Pressure indicator incorrect Pneumatic connections swapped Connect device correctly Chapter 6.2 Settings cannot be edited, [Lock] is displayed [min] + [max] flash simultaneously Display + [min] + [max] flash simultaneously Display flashes and error code appears Security code activated Enter security code Chapter 8.3 Diagnostic level 1 active Chapter 9.2 Diagnostic level 2 active Chapter 9.2 Diagnostic level 3 active Chapter 9.2 [Option] flashing Teach-In Faulty Set hysteresis larger, Teach-In repeat Tab Festo OVEM- -LK b English

37 10 Disassembly 1. Switch off energy sources. operating voltage compressed air 2. Disconnect pneumatic and electrical connections from the device. 3. Loosen mountings and remove device. 11 Maintenance and care Clean device 1. Switch off energy sources. operating voltage compressed air 2. Clean device with non-abrasive cleaning agents. 3. Check air filter through the inspection window for dirt. Replace air filter 2 1 Fig. 12 Remove / install air filter 1. Vent the vacuum generator. 2. Carefully pull out the slide 1 up to the first detent. The slide must stay in this position on the filter. 3. Pull out filter 2. Clean, if necessary. 4. Push filter into the housing. 5. Push in slide. The filter is pushed by the slide into the vacuum generator. Festo OVEM- -LK b English 37

38 12 Technical data OVEM / / -20 General Approval c UL us listed (OL) RCM CE mark In accordance with EU EMC Directive ( declaration of conformity) Characteristic values Operating pressure OVEM-...-QS / -GN / -PL [bar] 2 6 Operating pressure OVEM-...-QO / -GO / -PO [bar] 2 8 Pressure measuring range [bar] -1 0 Overload pressure at vacuum port [bar] 5 Ready-state delay [ms] 500 Dead time (evacuation and ejection) [ms] Electronics Nominal operating voltage [V DC] 24 ± 15 % Max. output current (for all switching outputs) [ma] 100 Voltage drop (for all switching outputs) [V] 1.8 Idle current [ma] 70 Coil characteristics, 24 V DC - low current phase [W] 0.3 Coil characteristics, 24 V DC - high current phase [W] 2.55 Time until current reduction [ms] 80 Capacitive load maximum DC [nf] 100 Overload protection Provided Inductive protective circuit Adapted to MZ, MY, ME coils Insulation voltage [V] 50 Surge resistance [kv] 0.8 Max. current consumption In IO-Link mode [ma] 150 In SIO-mode without master connection [ma] 270 Accuracy [% FS] ± 3 Hysteresis [% FS] ± 0.1 Short-circuit resistance Provided Protection against incorrect polarity For all electrical connections Display/operation Threshold value setting range [bar] Hysteresis setting range [bar] Festo OVEM- -LK b English

39 OVEM / / -20 Environment Ambient temperature [ C] 0 50 Temperature of medium [ C] 0 50 Operating medium Compressed air in accordance with ISO :2010 [7:4:4] Note on the operating medium Lubricated operation not possible Note on materials RoHS-compliant Resistance to shock (in accordance with IEC /EN60068) Vibration resistance (in accordance with EN ) Protection class 30 g acceleration with 11 s duration (half-sine) Hz: 0.35 mm / Hz: 5 g III Degree of protection 1) IP 65 Relative air humidity [%] 5 85 Interference emission In accordance with EN Interference immunity In accordance with EN Materials Information on materials - seals NBR Information on materials - housing Die-cast aluminium, PA reinforced Information on materials - plug housing housing Nickel-plated brass 1) Degree of protection not evaluated by UL Tab. 26 Festo OVEM- -LK b English 39

40 13 Appendix 13.1 Graphic display and LCD displays C 4 aj Status BDC1 (Out A Air-save) / BDC2 (Out A) 2 Status BDC3 (Out B) / diagnostics level Status IO-Link communication 4 4-digit alphanumeric display 5 Toolbar for functions Tab Segment bar to the right: graphic display of the current status of the digital inputs or valve status Tab B-key 8 A-key 9 EDIT button aj Segment bar to the left: Graphic display of the current pressure value related to the maximum measured value of the measuring range Fig. 13 LCD display and operating keys 40 Festo OVEM- -LK b English

41 Symbol C [SP] [SP] + [min] [SP] + [max] [HY] [NO] / [NC] [TeachIn] [Option] [Lock] <IOL> + [Lock] L1 L3 Tab. 27 L2 L10 L12 L16 L18 Description C flashes: IO-Link mode active Threshold value comparator selected Switchpoint Window comparator selected Lower switchpoint Upper switchpoint Hysteresis Switching logic normally open (Normally open) / normally closed (Normally closed) Teach-In mode active Air-saving function active Security code active Device Access Lock active The device can only be configured and parameterised in IO-Link operation. Segments of the graphic display of the current status of the digital inputs or valve status. Segment L10: status of the vacuum solenoid valve. Valve is switched when the segment is illuminated. Segment L12: status of the ejection pulse solenoid valve. Valve is switched when the segment is illuminated. Segment L16: status of the digital switching input DI1 (suction). Switching input set when segment is illuminated. Segment L18: status of the digital switching input DI2 (ejection). Switching input set when segment is illuminated. Symbolism in display Festo OVEM- -LK b English 41

42 Display Segment L17 + [A] illuminated and [min] flashing Segment L17 + [A] illuminated and [max] blinkt Segment L18 + [B] illuminated and [msec] + [_ _] flashing Description Display of minimum pressure value Display of maximum pressure value Duration of ejector pulse Segments L1, L3, L4, L5 illuminated and [msec] + [_ ] + [min] flashing [msec] + [_ ] + [max] flashing [msec] + [ _] + [max] flashing [msec] + [ _] + [max] flashing [msec] + [_ ] + [SP] + [max] flashing [msec] + [ _] + [SP] + [max] flashing Segments L1, L2, L5, L6 illuminated and display <ON> + [Option] flashing Segments L1, L2, L5, L6 illuminated and [Lock] flashing Segment L10 illuminated and symbol B illuminated + display <FORC> Diagnostics of evacuation and air supply times Display of minimum evacuation time Display of maximum evacuation time Display of minimum air supply time Display of maximum air supply time Setting of evacuation time limit value Setting air supply time limit Setting of air-saving function (EDIT mode) <ON>: Air-saving function active <OFF>: Air-saving function not active Setting security code (1 9999) <OFF>: Security code not active Additional functions of the electrical manual override via operating buttons Vacuum solenoid valve switched Segment L12 illuminated and symbol B illuminated + display <FORC> Additional functions of the electrical manual override via operating buttons Ejector pulse solenoid valve (Eject) switched Tab. 28 Examples for additional displays of segment bars 42 Festo OVEM- -LK b English

Pressure sensors SPAN

Pressure sensors SPAN Features At a glance Communication interface Convenient design Compact design 30x30 mm Degree of protection IP40 Reduced weight with QS4 Universal pressure measurement Pressure and vacuum 13 pressure measuring

More information

Positioner CMSX-...-C-U-F1-...

Positioner CMSX-...-C-U-F1-... Positioner CMSX-...-C-U-F-.... CMSX-SE-... (linear) 5 Festo AG & Co. KG Postfach Esslingen Germany +9-0 www.festo.com (en) Operating instructions 80595 0a [80595] aj 9 8 Housing cover Inspection window

More information

Position transmitter SDAT-MHS e [ ]

Position transmitter SDAT-MHS e [ ] Position transmitter SDAT-MHS en Manual 8068247 1612e [8068249] Translation of the original instructions SDAT-MHS This documentation refers to the following version: From Revision R04. Identification of

More information

Flow sensors SFAB Key features

Flow sensors SFAB Key features Key features At a glance Quick and secure installation thanks to QS fitting Display can be rotated 270 Manifold assembly of the sensor via H-rail or individual assembly via adapter plate for wall mounting

More information

IO-Link parameter description

IO-Link parameter description Application Note IO-Link parameter description A brief explanation of the contents - identification - parameter and commands - block parameterization - teach-in - process data - using different pressure

More information

Pressure sensors SDE1, with display

Pressure sensors SDE1, with display Product range overview Method of measurement Piezoresistive pressure sensor with display Operating voltage Measured variable Pressure measuring range Pneumatic connection Type of mounting Electrical output

More information

Pressure sensors SPAE

Pressure sensors SPAE Key features Function The SPAE is an electronic pressure sensor with piezoresistive pressure measuring cell, integrated signal processing, numerical percentage pressure indicator, control keys and a switching

More information

Pressure sensors SPAE

Pressure sensors SPAE Key features At a glance Single-button operation 7-segment display Various pneumatic connection options Switching status indication Choice of pressure ranges Function The SPAE is an electronic pressure

More information

Positioner CMSX-...-C-U-F1-...

Positioner CMSX-...-C-U-F1-... Positioner CMSX-...-C-U-F-.... CMSX-SE-... (linear) Festo AG & Co. KG Postfach Esslingen Germany +9-0 www.festo.com aj 9 8 (en) Operating instructions 8088 09NH [8080] Original: de Positioner CMSX... English

More information

System CPX-E. IO-Link master module CPX-E-4IOL- Description. Protocol IO-Link. Function Parameterisation [ ]

System CPX-E. IO-Link master module CPX-E-4IOL- Description. Protocol IO-Link. Function Parameterisation [ ] System CPX-E IO-Link master module CPX-E-4IOL- Description Protocol IO-Link Function Parameterisation 877 27-7 [879] IO-Link master module CPX-E-4IOL- Original instructions CPX-E-4IOL- -E N IO-Link is

More information

IO-Link parameter description

IO-Link parameter description Application Note IO-Link parameter description A brief explanation of the contents - identification - parameter and commands - block parameterization - teach-in - process data - using different pressure

More information

Pressure sensors SDE3, with display

Pressure sensors SDE3, with display Pressure sensors SDE3 Key features At a glance SDE3- -M plug version, plug M8x1 and M12x1 SDE3- -FQ, cable with plug Fast H-rail, wall or surface mounting Fast front panel mounting High-contrast, two-colour

More information

Operating instructions. Speed monitor D / / 2014

Operating instructions. Speed monitor D / / 2014 Operating instructions Speed monitor D200 80005257 / 00 05 / 2014 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5 2.2 Target group...5

More information

Operating instructions. Switching amplifier DN0210 DN / / 2015

Operating instructions. Switching amplifier DN0210 DN / / 2015 Operating instructions Switching amplifier DN0210 DN0220 UK 80011079 / 00 01 / 2015 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5

More information

Air gap sensors SOPA

Air gap sensors SOPA Product range overview Key features General Lightweight, compact and highly precise, this pneumatic solution offers impressive scope for integration: SOPA features a control module, compressed air regulation,

More information

Terminal CPX. Electrical interface CPX CTEL 4 M12 5POL. Description. CTEL master module. I-Port a [ ]

Terminal CPX. Electrical interface CPX CTEL 4 M12 5POL. Description. CTEL master module. I-Port a [ ] Terminal CPX Electrical interface CPX CTEL 4 M12 5POL Description CTEL master module I-Port 574601 1411a [8041791] Electrical interface CPX CTEL 4 M12 5POL Translation of the original instructions P.BE-CPX-CTEL-EN

More information

IO-Link parameter description

IO-Link parameter description Application Note IO-Link parameter description A brief explanation of the contents - identification - parameter and commands - block parameterization - teach-in - process data - using different pressure

More information

Flow sensors SFAM Key features

Flow sensors SFAM Key features Key features At a glance Threaded mounting of individual device with stabilising zone Can be combined with MS6 or MS9 series service units Illuminated LCD display with blue background and white 9-segment

More information

Service unit combinations MSE6, MSE series

Service unit combinations MSE6, MSE series Key features Overview Product description The MSE6-E2M is an intelligent pneumatic service unit for optimising the use of compressed air as an energy medium in industrial automation technology. Equipped

More information

Proximity sensors, block design

Proximity sensors, block design Proximity sensors, block design Proximity sensors, block design Product range overview Measuring principle Version Type Mounting Switching element function Switching Electrical connection N/O contact N/C

More information

Pressure sensors SDE5

Pressure sensors SDE5 q/w Worldwide: Superb: Easy: Festo core product range Covers 80% of your automation tasks Always in stock Festo quality at an attractive price Reduces procurement and storing complexity qready for dispatch

More information

Fork light barriers SOOF

Fork light barriers SOOF Product range overview Method of measurement Size Min. object diameter Max. switching frequency Switching output Type of light Page/ Internet [mm] [mm] [Hz] Metal light barrier SOOF-M- -C30 30x35 0.5 4,000

More information

Pressure sensors SDE5

Pressure sensors SDE5 Key features At a glance SDE5- -M8 Plug version, plug M8x1, 3-pin SDE5- -K Cable version, 2.5 m long, 3-wire Linkable wall bracket with clip-in facility for sensors (included in the scope of delivery)

More information

Operating instructions. Standstill monitor A / / 2011

Operating instructions. Standstill monitor A / / 2011 Operating instructions Standstill monitor A300 UK 1 2 3 4 5 6 7 8 7390337 / 01 02 / 2011 1 2 3 4 5 6 7 8 switchpoint min max pulse/min power Made in Germany ifm electronic gmbh D 45127 Essen func. I II

More information

Positioner CMSX-...-C-U-F1-...

Positioner CMSX-...-C-U-F1-... Positioner CMSX-...-C-U-F-... Festo AG & Co. KG Ruiter Straße 8 Esslingen Germany +9-0 www.festo.com Product overview. Function The CMSX digital electropneumatic positioner enables simple and efficient

More information

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description I/O extension module, eight digital transistor outputs Data sheet 105364_en_00 PHOENIX CONTACT 2013-03-26 1 Description The I/O extension module can be used in conjunction with Radioline wireless modules

More information

Operating instructions Memory plug E /02 11/2011

Operating instructions Memory plug E /02 11/2011 Operating instructions Memory plug E30398 UK 704930/02 11/2011 Contents 1 Preliminary note...3 1.1 Symbols used...3 1.2 Terms used...3 2 Safety instructions...4 3 Factory setting...4 4 Functions and features...5

More information

Sensor boxes SRBC. Festo core product range Covers 80% of your automation tasks

Sensor boxes SRBC. Festo core product range Covers 80% of your automation tasks Sensor boxes SRBC q/w Worldwide: Superb: Easy: Festo core product range Covers 80% of your automation tasks Always in stock Festo quality at an attractive price Reduces procurement and storing complexity

More information

Pressure sensors SDE1, with display

Pressure sensors SDE1, with display Product range overview Method of measurement Piezoresistive pressure sensor with display Operating voltage Measured variable Pressure measuring range Pneumatic connection Type of mounting Electrical output

More information

Operating instructions Pressure sensor. PN50xx / / 2010

Operating instructions Pressure sensor. PN50xx / / 2010 Operating instructions Pressure sensor PN50xx 704789 / 00 05 / 2010 Contents 1 Preliminary note...3 1.1 Symbols used...3 2 Safety instructions...3 3 Functions and features...4 4 Function...5 4.1 Processing

More information

Control unit SG-EFS 104/4L. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/4L AC/DC 24 V

Control unit SG-EFS 104/4L. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/4L AC/DC 24 V Innovative by tradition. Control unit SG-EFS 104/4L EN Operating instructions Version 2 1004128 SG-EFS 104/4L AC/DC 24 V Original instructions Mayser GmbH & Co. KG Örlinger Straße 1 3 89073 Ulm GERMANY

More information

Pressure switch RE B/ Type HEDE10.../1/ Operating instructions

Pressure switch RE B/ Type HEDE10.../1/ Operating instructions Pressure switch Type HEDE10.../1/ RE 30276-B/10.10 Replaces: 06.10 Operating instructions 2/20 Bosch Rexroth AG HEDE10.../1/ RE 30276-B/10.10 Contents 1 Overview of menu...3 2 Safety note... 4 3 Operating

More information

BNI IOL E012. IO-Link 1.1 sensor/actuator hub with extension port User's Guide

BNI IOL E012. IO-Link 1.1 sensor/actuator hub with extension port User's Guide BNI IOL322E12 IOLink 1.1 sensor/actuator hub with extension port User's Guide Balluff Network Interface / IOLink BNI IOL322E12 Contents 1 General 4 1.1. Structure of the Manual 4 1.2. Typographical Conventions

More information

Installation Instructions Temperature transmitter TAA /00 06/2011

Installation Instructions Temperature transmitter TAA /00 06/2011 Installation Instructions Temperature transmitter TAA431 706042/00 06/2011 Contents 1 Functions and features...3 2 Installation...4 2.1 Addressing...4 2.2 Mechanical installation...4 2.3 Connection to

More information

Compact performance. Brief description. CPV valve terminal with AS-Interface type CPV..-GE- ASI-8E8A-Z M8. English e [ ]

Compact performance. Brief description. CPV valve terminal with AS-Interface type CPV..-GE- ASI-8E8A-Z M8. English e [ ] Compact performance Brief description CPV valve terminal with AS-Interface type CPV..-GE- ASI-8E8A-Z M8 English 8080251 2017-11e [8080244] Translation of the original instructions Documentation on the

More information

Motor controllers CMMO-ST

Motor controllers CMMO-ST q/w Worldwide: Superb: Easy: Festo core product range Covers 80% of your automation tasks Always in stock Festo quality at an attractive price Reduces procurement and storing complexity qready for dispatch

More information

Sensor boxes SRBG Key features

Sensor boxes SRBG Key features Key features Function SRBG sensor boxes are the compact solution when it comes to electrical feedback signals and monitoring the position of process valves which are actuated with pneumatic quarter turn

More information

Operating instructions Pressure sensor. PN78xx / / 2010

Operating instructions Pressure sensor. PN78xx / / 2010 Operating instructions Pressure sensor PN78xx UK 704788 / 00 05 / 2010 Contents 1 Preliminary note3 1.1 Symbols used 3 2 Safety instructions 3 3 Functions and features 4 4 Function 5 4.1 Processing of

More information

OPT2041. Fiber Optic Cable Sensor. Operating Instructions. Available as PDF only Status:

OPT2041. Fiber Optic Cable Sensor. Operating Instructions. Available as PDF only Status: OPT2041 Fiber Optic Cable Sensor Operating Instructions Available as PDF only Status: 18.06.2018 www.wenglor.com Index 1. Proper Use 3 2. Safety Precautions 3 3. General Information Regarding the Device

More information

Pressure transmitters SPTE

Pressure transmitters SPTE Key features At a glance Compact design Very lightweight Various pneumatic connection options Output signal: 0 10 V or 1 5 V Choice of pressure ranges Pneumatic connections Push-in sleeve Push-in connector

More information

Pressure sensors SPAE

Pressure sensors SPAE Key features At a glance Single-button operation 7-segment display Various pneumatic connection options Switching status indication Choice of pressure ranges Function The SPAE is an electronic pressure

More information

Proximity sensors, block-shaped Product range overview

Proximity sensors, block-shaped Product range overview Proximity sensors, block-shaped Product range overview Measuring Version Type Assembly Switching element function Switch output Electricalconnection principle N/C contact Cable Plug Magneto- Operating

More information

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064 Monitoring technique VARIMETER Voltage relay MK 9064N, MH 9064 0269462 Your Advantages Preventive maintenance For better productivity Quicker fault locating Precise and reliable Min-, Max. value or window

More information

OPT2011. High-performance distance sensor. Operating Instructions

OPT2011. High-performance distance sensor. Operating Instructions OPT2011 High-performance distance sensor Operating Instructions Status: 15/07/2013 2 Table of Contents 1. Use for Intended Purpose 4 2. Safety Precautions 4 2.1. Safety Precautions 4 2.2. Laser/LED warning

More information

QUINT-BUFFER/24DC/24DC/40

QUINT-BUFFER/24DC/24DC/40 Buffer module Data sheet 105496_en_01 PHOENIX CONTACT 2013-11-01 1 Description The QUINT BUFFER buffer module combines the electronic switchover unit and power storage in the same housing. The buffer module

More information

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description I/O extension module with 8 digital inputs or 2 pulse inputs INTERFACE Data sheet 0483_en_00 PHOENIX CONTACT 203-04-05 Description The I/O extension module can be used in conjunction with Radioline wireless

More information

Original operating instructions Fail-safe inductive sensor GI711S / / 2010

Original operating instructions Fail-safe inductive sensor GI711S / / 2010 Original operating instructions Fail-safe inductive sensor GI7S 704583 / 0 06 / 200 Contents Preliminary note 3. Explanation of symbols 3 2 Safety instructions 4 2. Safety-related requirements regarding

More information

Dimensions. Model Number. Electrical connection. Features. Pinout. Product information. Indicators/operating means OMT300-R201-IEP-IO-V1

Dimensions. Model Number. Electrical connection. Features. Pinout. Product information. Indicators/operating means OMT300-R201-IEP-IO-V1 Dimensions. 9.9 6 Model Number 6.7 Ref. 6. 5. 5.8 7 7.7.6 ø. 9 50 78.5 Receiver Emitter M x..7 sensor with -pin, M x connector Electrical connection Features Medium design with versatile mounting options

More information

Technical data. General specifications. factory setting: 125 ms Memory Non-volatile memory Write cycles Indicators/operating means

Technical data. General specifications. factory setting: 125 ms Memory Non-volatile memory Write cycles Indicators/operating means Model Number Single head system Features IO-link interface for service and process data Programmable via DTM with PACTWARE Switch output and analog output Selectable sound lobe width Synchronization options

More information

Pressure sensors SPAB, with display

Pressure sensors SPAB, with display Key features, product range overview At a glance Variants: Plug M8x1 with electric adapter SASC Plug, square design L1 Cable version with connecting cable NEBS Compact design 30 x 30 mm Multi-coloured,

More information

Original operating instructions Safety relay with relay outputs with and without delay G1502S / / 2016

Original operating instructions Safety relay with relay outputs with and without delay G1502S / / 2016 Original operating instructions Safety relay with relay outputs with and without delay UK G50S 803638 / 00 0 / 06 Contents Preliminary note...4. Symbols used...4 Safety instructions...5 3 Items supplied...6

More information

Air gap sensors SOPA

Air gap sensors SOPA Product range overview Key features General Lightweight, compact and highly precise, this pneumatic solution offers impressive scope for integration: SOPA features a control module, compressed air regulation,

More information

CPX-E-CEC-... Controller. Description Function, Parameterisation [ ]

CPX-E-CEC-... Controller. Description Function, Parameterisation [ ] CPX-E-CEC-... Controller Description Function, Parameterisation 8071235 8071235 2018-09 [8071237] Translation of the original instructions CODESYS, EtherCAT, MODBUS are registered trademarks of the respective

More information

BNI IOL Z046. IO-Link 1.1 sensor/actuator hub with extension port User's Guide

BNI IOL Z046. IO-Link 1.1 sensor/actuator hub with extension port User's Guide BNI IOL302002Z046 IOLink 1.1 sensor/actuator hub with extension port User's Guide Balluff Network Interface / IOLink BNI IOL302002Z046 Contents 1 General 4 1.1. Structure of the Manual 4 1.2. Typographical

More information

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016 Operating instructions AS-i SmartLine module AC3200 AC3201 80237876/00 06/2016 Contents 1 Preliminary note...3 1.1 Symbols used...3 1.2 Warnings used...3 2 Safety instructions...3 2.1 General...3 2.2 Target

More information

Manual LioN-P - IO-Link Device - I/O Hub

Manual LioN-P - IO-Link Device - I/O Hub Manual LioN-P - IO-Link Device - I/O Hub 0960 IOL 381-001 0960 IOL 385-001 0960 IOL 380-021 Technical Support support-automation@belden.com Contents Contents 1 About this Manual 6 1.1 General Information

More information

Operating instructions Pressure sensor. PN70xx / / 2012

Operating instructions Pressure sensor. PN70xx / / 2012 Operating instructions Pressure sensor PN70xx 706136 / 00 01 / 2012 Contents 1 Preliminary note...3 1.1 ymbols used...3 2 afety instructions...3 3 Functions and features...4 4 Function...5 4.1 Communication,

More information

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

Rhino Redundancy Module PSM24-REM360S. Operating Instructions Rhino Redundancy Module PSM4-REM360S Operating Instructions RHINO REDUNDANCY MODULE PSM4-REM360S Description With this module and two power supplies of the PSM series (78, 90, 56, 80 and 360 watt models),

More information

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600 REDUNDANCY MODULE TSP-REM360 AND TSP-REM600 Operating Instructions Seite 1 Dimensions drawings: TSP-REM360 Weight: 0.882lb Gewicht: 0.40kg Seite 2 Dimensions drawings: TSP-REM600 Bottom view Top view Side

More information

BNI IOL A027 BNI IOL A027

BNI IOL A027 BNI IOL A027 BNI IOL-771-000-A027 BNI IOL-772-000-A027 IO-Link Version 1.1 Universel IO-Link Interface With undervoltage / broken coil detection User s Guide Inhalt 1 Notes to the user 2 1.1. About this guide 2 1.2.

More information

Controller CMXH-ST2 Key features

Controller CMXH-ST2 Key features Key features At a glance The controller controls two servo motors which drive an H-shaped rotating toothed belt. The toothed belt moves a slide, whose position is calculated by the controller from the

More information

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

Rhino Buffer Module PSM24-BFM600S. Operating Instructions Rhino Buffer Module PSM24-BFM600S Operating Instructions RHINO BUFFER MODULE PSM24-BFM600S Description The PSM24-BFM600S Buffer Module will hold the output voltage of a 24 VDC power supply after brownouts

More information

Pressure sensors SPAW with display

Pressure sensors SPAW with display Key features At a glance 9 pressure ranges from 1 +1 bar up to 0 +100 bar 4-digit LED display, easy to read, robust Protection class IP67 320 rotatable display 1% accuracy, 0.15% repetition accuracy Temperature

More information

SM9000. Magnetic-inductive flow meter. Made in Germany

SM9000. Magnetic-inductive flow meter. Made in Germany Made in Germany Application Application totaliser function; empty pipe detection; for industrial applications Installation connection to pipe by means of an adapter Media conductive liquids; water; hydrous

More information

Controller CMXH. Description STO. Safe Torque Off (STO) [ ]

Controller CMXH. Description STO. Safe Torque Off (STO) [ ] Controller CMXH Description STO Safe Torque Off (STO) 8062612 1603 [8062614] CMXH Translation of the original instructions CMXH-STO-EN Identification of hazards and instructions on how to prevent them:

More information

BNI IOL Z046. IO-Link 1.1 Sensor hub with extension port User's Guide

BNI IOL Z046. IO-Link 1.1 Sensor hub with extension port User's Guide BNI IOL104002Z046 IOLink 1.1 Sensor hub with extension port User's Guide Balluff Network Interface / IOLink BNI IOL104002Z046 Contents 1 General 4 1.1. Structure of the Manual 4 1.2. Typographical Conventions

More information

GEMÜ 1235 Electrical position indicator

GEMÜ 1235 Electrical position indicator Electrical position indicator Features Communication and programming interface IO-Link Adjustable switch point tolerances Speed-AP function for fast mounting and initialisation High visibility position

More information

Dimensions. Model Number. Electrical connection emitter. Features. Electrical connection receiver. Product information. Pinout OBE12M-R100-S2EP-IO-V31

Dimensions. Model Number. Electrical connection emitter. Features. Electrical connection receiver. Product information. Pinout OBE12M-R100-S2EP-IO-V31 OBEM-R00-SEP-IO-V Dimensions. 8.7. 7..9. M (x).. ø... 0 9.9 7. 7. Release date: 08-06-08 :0 Date of issue: 08-06-08 80998_eng.xml Model Number OBEM-R00-SEP-IO-V Thru-beam sensor with -pin, M8 x connector

More information

Terminal CPX. Electrical interface CPX-CTEL-2-M12-5POL-LK. Description Electronics NH [ ]

Terminal CPX. Electrical interface CPX-CTEL-2-M12-5POL-LK. Description Electronics NH [ ] Terminal CPX Electrical interface CPX-CTEL-2-M12-5POL-LK Description Electronics 8034116 1405NH [8034124] Electrical interface CPX-CTEL-2-M12-5POL-LK Translation of the original instructions P.BE-CPX-CTEL-LK-EN

More information

Operating instructions Electronic temperature sensor TN /00 04/2011

Operating instructions Electronic temperature sensor TN /00 04/2011 Operating instructions Electronic temperature sensor TN7531 UK 704772/00 04/2011 Contents 1 Preliminary note3 1.1 ymbols used 3 2 afety instructions 3 3 Functions and features 4 4 Function 4 4.1 Communication,

More information

Dimensions. Model Number. Electrical connection. Features. Pinout. Indicators/operating means. Product information OQT150-R100-2EP-IO-V31

Dimensions. Model Number. Electrical connection. Features. Pinout. Indicators/operating means. Product information OQT150-R100-2EP-IO-V31 Dimensions.5 8.7 5.5.5. M (x)..5 7. 5.. 0 5.9 7. 9.95 Reveiver Emitter ø. Model Number Triangulation sensor (SbR) with -pin, M8 x connector Features Miniature design with versatile mounting options Multi

More information

Fork light barriers SOOF

Fork light barriers SOOF Product range overview Method of measurement Size Min. object diameter Max. switching frequency Switching output Type of light Page/ Internet [mm] [mm] [Hz] Metal light barrier SOOF-M- -C30 30x35 0.5 4,000

More information

Original operating instructions Fail-safe inductive sensor GF711S / / 2013

Original operating instructions Fail-safe inductive sensor GF711S / / 2013 Original operating instructions Fail-safe inductive sensor GF7S 8528 / 5 / 23 Contents Preliminary note...3. Explanation of symbols...3 2 Safety instructions...4 2. Safety-related requirements regarding

More information

Power supply module, bus connection module

Power supply module, bus connection module s 8 183 8183p01, p02 TX-I/O Power supply module, bus connection module TXS1.12F10 TXS1.EF10 Each I/O row begins with one of these devices TXS1.12F10 power supply module Up to 4 power supply modules can

More information

Operating instructions Electronic pressure sensor PN7xxx

Operating instructions Electronic pressure sensor PN7xxx Operating instructions Electronic pressure sensor PN7xxx 8000579 / 00 08 / 208 Contents Preliminary note...4. Symbols used...4 2 Safety instructions...4 3 Functions and features...5 3. Applications...5

More information

PHOENIX CONTACT - 07/2006

PHOENIX CONTACT - 07/2006 Buffer module with maintenance-free capacitor-based power storage device INTERFACE Data sheet 102035_03_en PHOENIX CONTACT - 07/2006 Description Short-term mains interruptions are bridged by QUINT BUFFER,

More information

Pressure Transmitters with IO-Link BSP-Bxxx-xx004-xxxS1A-xx, BSP-Vxxx-xx004-xxxS1A-xx

Pressure Transmitters with IO-Link BSP-Bxxx-xx004-xxxS1A-xx, BSP-Vxxx-xx004-xxxS1A-xx EU Directive 2004/108/EC (EMC Directive) and EMC Law Generic Standards: EN 61000-6-4 (Emissions), EN 61000-6-2 (Interference Immunity) Emissions testing: Radio interference emissions EN 55011 Group 1,

More information

Operating instructions Electronic pressure sensor. PM205x /01 09/2011

Operating instructions Electronic pressure sensor. PM205x /01 09/2011 Operating instructions Electronic pressure sensor PM205x 706071/01 09/2011 Contents 1 Preliminary note...3 1.1 Symbols used...3 2 Safety instructions...3 3 Functions and features...4 3.1 Applications...4

More information

Original operating instructions Safety relay with relay outputs G1501S / / 2016

Original operating instructions Safety relay with relay outputs G1501S / / 2016 Original operating instructions Safety relay with relay outputs G50S UK 8023637 / 00 02 / 206 Contents Preliminary note...4. Symbols used...4 2 Safety instructions...5 3 Items supplied...6 4 Functions

More information

RM35JA32MR Current control relay 0.15A 15A, 2 C/O

RM35JA32MR Current control relay 0.15A 15A, 2 C/O Characteristics Current control relay 0.15A 15A, 2 C/O Main Range of product Product or component type Relay type Relay name Relay monitored parameters Time delay type Switching capacity in VA Measurement

More information

Rotary actuator for ball valves KNX / PL-Link

Rotary actuator for ball valves KNX / PL-Link s ACVATIX Rotary actuator for ball valves KNX / PL-Link G..B111.9E/KN Rotary actuator 5 / 10 Nm with KNX communication for 6-port control ball valves and ball valves GDB111.9E/KN with 5 Nm nominal torque

More information

PSR-MS60. Safety relay for emergency stop, safety door and light grid monitoring. Data sheet. 1 Description

PSR-MS60. Safety relay for emergency stop, safety door and light grid monitoring. Data sheet. 1 Description SILCL IEC 62061 Safety relay for emergency stop, safety door and light grid monitoring Data sheet 106171_en_01 PHOENIX CONTACT 2015-05-19 1 Description Intended Use The PSR-MS60 safety relay can be used

More information

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH Industriefunkuhren Technical Manual Signal Converter for DIN Rail Mounting Series 4800xx-yy ENGLISH Version: 01.01-19.07.2007 2 / 23 Signal Converter 4800 - V01.01 INPORTANT NOTES Downloading Technical

More information

Safety System CES-FD. Non-contact safety system CES-FD- Direct connection to decentralized peripheral systems (e.g. ET200pro) PLC

Safety System CES-FD. Non-contact safety system CES-FD- Direct connection to decentralized peripheral systems (e.g. ET200pro) PLC Non-contact safety system CES-FD- Evaluation of signals in the field Connection of CES read heads Connection to the ET200s and ET200pro Familiar EUCHNER AP interface Functional description Field evaluation

More information

Operating instructions Electronic pressure sensor. PN72xx PN73xx PN76xx / / 2016

Operating instructions Electronic pressure sensor. PN72xx PN73xx PN76xx / / 2016 Operating instructions Electronic pressure sensor PN72xx PN73xx PN76xx 8002464 / 00 07 / 206 Contents Preliminary note...4. Symbols used...4 2 Safety instructions...4 3 Functions and features...5 3. Applications...5

More information

XUK8TAKSMM12 photo-electric sensor - XUK - diffuse - Sn 5m 1Q auto PNP/NPN

XUK8TAKSMM12 photo-electric sensor - XUK - diffuse - Sn 5m 1Q auto PNP/NPN Characteristics photo-electric sensor - XUK - diffuse - Sn 5m 1Q auto PNP/NPN Complementary Enclosure material Lens material Maximum sensing distance Output type Add on input Wire insulation material Status

More information

Proximity sensors SME-8, for T-slot Technical data Magnetic reed

Proximity sensors SME-8, for T-slot Technical data Magnetic reed Function e.g. N/O contact, with cable, 3-wire Magnetic reed measuring principle Insertable in the slot lengthwise e.g. N/O contact, with plug, 3-pin SME-8-SL Sturdy thanks to long guides Plug directly

More information

BNI IOL-104-S01-Z012-C02

BNI IOL-104-S01-Z012-C02 BNI IOL104S01Z012C01 BNI IOL104S01Z012C02 BNI IOL302S01Z013C01 User s Guide Balluff Network Interface / IOLink 1 Notes for the user 1.1 About this guide 2 1.2 Structure of the guide 2 1.3 Typographical

More information

BNI IOL Z019. IO-Link 1.1 sensor hub With extension port User s Guide

BNI IOL Z019. IO-Link 1.1 sensor hub With extension port User s Guide BNI IOL102002Z019 IOLink 1.1 sensor hub With extension port User s Guide Balluff Network Interface / IOLink BNI IOL102002Z019 Inhalt 1 Notes for the user 4 1.1. About this manual 4 1.2. Structure of the

More information

Operating instructions Control monitor for temperature sensors TR /00 04/2011

Operating instructions Control monitor for temperature sensors TR /00 04/2011 Operating instructions Control monitor for temperature sensors TR7432 704773/00 04/20 Contents Preliminary note3. ymbols used 3 2 afety instructions 3 3 Functions and features 4 4 Function 4 4. Communication,

More information

Connecting cables for valves, plug pattern ZC, metric screw Type codes

Connecting cables for valves, plug pattern ZC, metric screw Type codes Type codes NEBV Z4 WA 2 L R E 5 N M8 G 3 S1 Function NEBV Connecting cables for valves Connection technology on left, field device side Z4 Socket, plug pattern ZC, metric screw Cable outlet left WA Angled

More information

Proximity sensors SME-8M, for T-slot Technical data Magnetic reed

Proximity sensors SME-8M, for T-slot Technical data Magnetic reed Function e.g., 3-wire, with cable e.g., 3-wire, with plug Magnetic reed measuring principle Insertable in the slot from above, does not protrude over the cylinder profile Cable clip and inscription labels

More information

BNI IOL Z026 BNI IOL-302-S01-Z026 User s Guide

BNI IOL Z026 BNI IOL-302-S01-Z026 User s Guide BNI IOL302000Z026 BNI IOL302S01Z026 User s Guide 1 Notes for the user 1.1 About this guide 2 1.2 Structure of the guide 2 1.3 Typographical conventions 2 1.3.1 Enumerations 2 1.3.2 Actions 2 1.3.3 Syntax

More information

BNI IOL Z026 BNI IOL-302-S01-Z026. User s Guide

BNI IOL Z026 BNI IOL-302-S01-Z026. User s Guide BNI IOL302000Z026 BNI IOL302S01Z026 User s Guide Balluff Network Interface / IOLink BNI IOL302xxxZ026 1 Notes for the user 1.1 About this guide 2 1.2 Structure of the guide 2 1.3 Typographical conventions

More information

RAD-DOR4-IFS. I/O extension module, 4 digital relay outputs. INTERFACE Data sheet. 1 Description

RAD-DOR4-IFS. I/O extension module, 4 digital relay outputs. INTERFACE Data sheet. 1 Description I/O extension module, 4 digital relay outputs INTERFACE Data sheet 104834_en_01 PHOENIX CONTACT 2013-01-21 1 Description The RAD-DOR4-IFS I/O extension module can be used in conjunction with Radioline

More information

Operating Instructions

Operating Instructions TPS S1 AC in DC out Translation of the original instructions TPS 110-400 Mains pack Operating Instructions PT 0199 BEN/C (1010) EN Table of contents Table of contents 1 About this manual...............................................

More information

Installation instructions Diagnostic electronics for vibration sensors VSE / / 2007

Installation instructions Diagnostic electronics for vibration sensors VSE / / 2007 Installation instructions Diagnostic electronics for vibration sensors UK VSE00 70406 / 00 07 / 2007 Contents Safety instructions 3 Function and features 4 Mounting 4 Mounting of the sensors 5 Electrical

More information

Motion Terminal VTEM. Description. Motion App #04. Model-based proportional pressure regulation [ ]

Motion Terminal VTEM. Description. Motion App #04. Model-based proportional pressure regulation [ ] Motion Terminal VTEM Description Motion App #04 Model-based proportional pressure regulation 8086805 2018-05 [8086807] VTEM Translation of the original instructions VTEM-MA04-E N Firefox is a registered

More information

Proximity sensors, round design

Proximity sensors, round design Proximity sensors, round design Proximity sensors, round design Product range overview Measuring principle Magnetoinductive Version Type Assembly Switching element function Switch output Electrical connection

More information

BNI IOL K023 BNI IOL K023. User s Guide

BNI IOL K023 BNI IOL K023. User s Guide BNI IOL-712-000-K023 BNI IOL-714-000-K023 User s Guide Content 1 Notes 2 1.1. Struture of the guide 2 1.2. Typographical conventions 2 Enumerations 2 Actions 2 Syntax 2 Cross references 2 1.3. Symbols

More information