Elos Fixturlaser AB. Generator alignment
|
|
- Anis Dawson
- 6 years ago
- Views:
Transcription
1 Elos Fixturlaser AB Generator alignment with Fixturlaser GO WORK Applies INSTRUCTION on Vestas turbines FOR of the USING types: FIXTURLASER V47, V52, V63, V66, GO V80, ON V90 VESTAS GENERATORS HHI 7/9/2009
2 Elos Fixturlaser AB Generator alignment with Fixturlaser GO Page 2 of 13 CONTENTS Work instruction for using Fixturlaser GO on Vestas generators... 1 Safety... 3 Educational Requirements... 3 Required Documentation... 3 Purpose... 3 Risk Assessment... 3 NOTE... 3 TOOLS... 3 Spare parts... 3 Weights... 3 Estimated time use... 3 Procedure... 3 Preparation... 3 Dismounting of coupling... 4 Alignment equipment Fixturlaser GO... 4 Mounting of equipment for alignment... 5 Measurement procedure... 7 Setting of tolerances... 7 Setting of target values (were applicable)... 8 Measuring... 9 Explanation of the result screen Alignment... 13
3 Elos Fixturlaser AB Generator alignment with Fixturlaser GO Page 3 of 13 SAFETY Carry out the work in accordance EDUCATIONAL REQUIREMENTS The service technician must possess REQUIRED DOCUMENTATION Document this Document that PURPOSE This instruction describes how to align the generator with the Fixturlaser GO alignment equipment RISK ASSESSMENT Some info goes here NOTE Always read the entire instruction and the attached risk assessment before the work is started TOOLS Item No Quantity Text 1 Laser alignment tool VT Turning Brake Disc SPARE PARTS Item No Quantity Text WEIGHTS Some info goes here ESTIMATED TIME USE Some info goes here PROCEDURE PREPARATION Before aligning with Fixturlaser GO the gearbox must be aligned according to the type of turbine, see O&M manual for the turbine type in question.
4 Elos Fixturlaser AB Generator alignment with Fixturlaser GO Page 4 of 13 For dismounting of the composite coupling the turbine must be braked and locked During the alignment the turbine and the rotor must be braked and locked, the blades must be in 90 position and the nacelle must be against the wind Maximum wind speed is according to Safety Regulations for Operators and Technicians. Turn off main switches. DISMOUNTING OF COUPLING Rotating parts Risk of being caught by rotating parts Do not work on rotating parts Lock the rotor before carrying out any work on the coupling or other rotating parts in the drive train. Stay at a safe distance from the coupling when it is being rotated without the cover mounted over it. Risk of hurting hands and feet Risk of squeezing hands and feet between brackets and brake disc flange when turning brake disc by hand Do not turn the brake disc by hand, always use VT , Turning Brake Disc. ALIGNMENT EQUIPMENT FIXTURLASER GO 1. RS-485 connectors (IP 54) 2. Alfa-numeric keyboard 3. Alignment status indicators a. Green within tolerance b. Orange within double tolerance c. Red out of double tolerance 4. On/Off button 5. Navigation buttons
5 Elos Fixturlaser AB Generator alignment with Fixturlaser GO Page 5 of 13 MOUNTING OF EQUIPMENT FOR ALIGNMENT Mounting of equipment with the coupling dismounted The S unit mounted on the gearbox side The M unit mounted on the generator side The picture shows how the fixtures are mounted on the respective side of the coupling
6 Elos Fixturlaser AB Generator alignment with Fixturlaser GO Page 6 of 13 Alternative mounting of equipment without removing the coupling Utilizing exiting coupling bolts to attach the fixtures with the S and M units. NOTE The M unit must be mounted on the generator side and the S unit on the gearbox side Each sensor unit is connected with cable to the display unit. It does not matter to which connector each unit is connected.
7 Elos Fixturlaser AB Generator alignment with Fixturlaser GO Page 7 of 13 MEASUREMENT PROCEDURE Operator Description Turn on the system Use the arrow keys to navigate to the icon for Horizontal shaft alignment. Press the OK button. Unlock the post fixings on the M unit and adjust the height of the unit so the laser line projected on the S unit is approximately in the middle of the sensor area. Lock the post fixings. SETTING OF TOLERANCES Operator Description Navigate to the Toolbox icon and press the OK button. Navigate to the tolerance table and press the OK button. Enter the specified tolerances for the machine you are about to align. Tolerances are found in the machine specification documents. Navigate to the exit icon and press the OK button.
8 Elos Fixturlaser AB Generator alignment with Fixturlaser GO Page 8 of 13 SETTING OF TARGET VALUES (WERE APPLICABLE) Operator Description Navigate to the Target values icon and press the OK button. Navigate to the Coupling values icon and press the OK button. Enter the specified target values, i.e. thermal growth values, in each of the available fields. The target values can be found in the machine specification documents. When finished, navigate to the OK icon and press the OK button. By entering target values into the system the alignment can be accomplished towards zero values and thereby utilizes the systems functionality for guiding the operator towards an alignment within tolerances.
9 Elos Fixturlaser AB Generator alignment with Fixturlaser GO Page 9 of 13 MEASURING Operator Description Measure the distance between the sensor heads. The measurement must be taken between the post centres. Enter the distance between the sensor heads. Press the OK button. The next measurement is automatically entered as half of the previous measurement. It represents the center of the coupling. Press the OK button. Measure the distance from the post centre of the M unit to the centre of the front generator foot Enter the value and press the OK button.
10 Elos Fixturlaser AB Generator alignment with Fixturlaser GO Page 10 of 13 Measure the distance between the centers of the front foot and the rear foot of the generator. Enter the values and press the OK button. Rotate the sensors to the 9 o clock position. The angle indicator on top of the screen guides you to position both sensors correctly. Navigate with the arrow keys to the measure icon and press the OK button to register the first reading of three. While the system samples the data this symbol is displayed on the screen. Rotate both sensor heads to the 3 o clock position and press the OK button to register the second reading.
11 Elos Fixturlaser AB Generator alignment with Fixturlaser GO Page 11 of 13 Rotate the sensor heads to the 12 o clock position and press the OK button to register the third and final reading. The result screen shows the generator position relative to the gearbox. Navigate to the Save icon and press the OK button. Save the measurement as an As found measurement. Name the measurement with the turbine identification. Note that the system utilizes multi tap technology, i.e. press the button several times to select between alphanumerical characters.
12 Elos Fixturlaser AB Generator alignment with Fixturlaser GO Page 12 of 13 EXPLANATION OF THE RESULT SCREEN The generators vertical position The generators horizontal position Parallel offset Angular misalignment Foot values shows the position relative to ideal position Within tolerance Outside tolerance Three LEDs on the Display Unit indicates the status of the coupling Green Within tolerance. Yellow Within double tolerance. Red Out of double tolerance.
13 Elos Fixturlaser AB Generator alignment with Fixturlaser GO Page 13 of 13 ALIGNMENT Operator Description Navigate with the arrow keys to the Shim icon and press the OK button. The screen displays live values and the arrows show you the direction you need to move the generator. Move the generator vertically by adding or removing shims until the alignment is within tolerances. Rotate the sensor heads to the 3 0 clock position. The screen changes to display the horizontal position of the generator. Move the generator according to the arrows until alignment within tolerances is achieved. When alignment is achieved, navigate with the arrow keys to the Re measure icon and press the OK button. Repeat the procedure under the Measurement headline and finalize by saving the measurement as an As left measurement.
E710 / E720. Machine Alignment and Installation E710 / E720
E710 / E720 Machine Alignment and Installation E710 / E720 SHAFT ALIGNMENT HORIZONTAL MACHINES Horizontally coupled machines often consist of a pump and motor, but there can also be other types of machine
More informationSHAFT ALIGNMENT. Quick, simple and effective! PC SOFTWARE INCLUDED PRINTER CONNECTION EXPANDABLE MEASUREMENT VALUE FILTER COMPENSATION THERMAL GROWTH
D505 D525 SHAFT ALIGNMENT Quick, simple and effective! PC SOFTWARE INCLUDED PRINTER CONNECTION EXPANDABLE COMPENSATION THERMAL GROWTH TOLERANCE CHECK MEASUREMENT VALUE FILTER 40 MINIMUM ROTATION FOR ALL
More informationD550 Extreme SHAFT ALIGNMENT. For alignment in potentially explosive environments (ATEX/Ex) 4-YEAR WARRANTY
D550 Extreme 4-YEAR WARRANTY SHAFT ALIGNMENT For alignment in potentially explosive environments (ATEX/Ex) FOR EXTREME ENVIRONMENTS Easy-Laser Extreme is one of the toughest and most robust measurement
More informationSHAFT ALIGNMENT. Compact size! Professional measurement and alignment system for rotating machines.
EXPANDABLE QUICK START 40 MIN. ROTATION BUILT-IN WIRELESS UNITS Compact size! Fits most machine types also when space is limited. SHAFT ALIGNMENT Professional measurement and alignment system for rotating
More informationSKF Shaft Alignment Tool Vertical machines app
SKF Shaft Alignment Tool Vertical machines app Flange mounted machines Instructions for use Table of contents 1. Using the Vertical shaft alignment app... 2 1.1 How to change the app language...2 1.2
More informationS-650 Coupling Alignment System
S-650 Coupling A new generation of 5-axis, real-time coupling alignment systems. Geometric Alignment Laser Systems The Best Choice in Coupling Alignment is Easy to See 1 Largest target cell size on the
More informationGeometry Measurements
Geometry Measurements Welcome to our world Since the very beginning in 1984, ACOEM AB has helped industries throughout the world to achieve more profitable and sustainable production. We have reached where
More informationHow to use Leica DISTO D510
How to use Leica DISTO D510 Switch On and Off The Press key switches and activates the laser in a single press. once quickly to shoot a distance or... Press and hold for 2 seconds to activate continuous
More informationUSER MANUAL Fixturlaser ECO
USER MANUAL Fixturlaser ECO CONTENT Welcome to our world 1.1 Declaration of Conformity 2.1 Safety 3.1 Care 4.1 Main Menu 5.1 Shaft Alignment 6.1 Horizontal Machines Softcheck 7.1 Memory Manager 8.1 Global
More informationQUICK START 40 MIN. ROTATION ENTERING SHAFT ALIGNMENT. Professional measurement and alignment system for rotating machines
EXPANDABLE QUICK START 40 MIN. ROTATION BARCODE ENTERING SHAFT ALIGNMENT Professional measurement and alignment system for rotating machines SIMPLY EFFICIENT! OPTIMIZE OPERATING CONDITIONS Easy-Laser E530
More informationSHAFT ALIGNMENT. Quick, simple and effective! PC SOFTWARE INCLUDED PRINTER CONNECTION EXPANDABLE MEASUREMENT VALUE FILTER COMPENSATION THERMAL GROWTH
D505 D525 SHAFT ALIGNMENT Quick, simple and effective! PC SOFTWARE INCLUDED PRINTER CONNECTION EXPANDABLE COMPENSATION THERMAL GROWTH TOLERANCE CHECK MEASUREMENT VALUE FILTER 40 MINIMUM ROTATION FOR ALL
More informationOPERATING INSTRUCTIONS:
List OPERATING INSTRUCTIONS: Preparation For Installation, Product Identification Charging The Batteries ing And Adjusting The Lift Mounting Head s Brackets Mounting Clamps And Quick-Locking Arms Installation
More informationE540. Shaft Alignment E540
E540 Shaft Alignment E540 SIMPLY EFFICIENT! OPTIMIZE OPERATING CONDITIONS Easy-Laser E540 is a precise and competent alignment system for your rotating machinery. Easy-Laser E540 provides the ideal balance
More informationUSER MANUAL Fixturlaser NXA
USER MANUAL Fixturlaser NXA CONTENT Welcome to our world 1.1 Declaration of Conformity 2.1 Safety 3.1 Care 4.1 Main Menu 5.1 Shaft Alignment 6.1 Horizontal Machines Shaft Alignment 7.1 Vertical Machines
More informationWelcome to our world.
Fixturlaser NXA Pro Welcome to our world. Since the very beginning in 1984, ELOS Fixturlaser has helped industries throughout the world to achieve more profitable and sustainable production. We have reached
More informationSTEALTH SERIES SHAFT ALIGNMENT SYSTEMS S - 670CRT & S - 670T W I R E L E S S 3 - A X I S
ALIGN WITH THE BEST STEALTH SERIES SHAFT ALIGNMENT SYSTEMS S - 670CRT & S - 670T W I R E L E S S 3 - A X I S Highest Accuracy in its Class MS Windows 8 Rugged Tablets Patented Dual-Beam Technology Any
More informationALiSENSOR. ALiSENSOR SHAFTLASER. Modern Shaft Alignment
ALiSENSOR SHAFTLASER ALiSENSOR SHAFTLASER Modern Shaft Alignment Index 1 Introduction 2 The System 3 Shaft Alignment Horizontal machines 4 Equipment Setup 5 Alternative Setup methods 6 Start Shaft Alignment
More informationSKF Shaft Alignment Tool TKSA 31 & TKSA 41. Quick Start Guide
SKF Shaft Alignment Tool TKSA 31 & TKSA 41 Quick Start Guide 1. Case content 8 1 6 9 5 2 7 4 4 3 1. 1 TKSA 31/41 Display unit 2. 1 TKSA 31/41 S Measuring unit 3. 1 TKSA 31/41 M Measuring unit 4. 2 Shaft
More informationTABLE OF CONTENTS TABLE OF CONTENTS... 1 MANUAL REVISION HISTORY... 2 IMPORTANT SAFETY NOTICE...
TABLE OF CONTENTS TABLE OF CONTENTS... 1 MANUAL REVISION HISTORY... 2 IMPORTANT SAFETY NOTICE... 3 1.0 General Information... 5 1.1 System Components... 5 1.2 Specifications... 5 1.2.1 Torque Ranges...
More informationWelcome to our world.
Fixturlaser NXA Pro Welcome to our world. Since the very beginning in 1984, ACOEM AB has helped industries throughout the world to achieve more profitable and sustainable production. We have reached where
More informationSTEALTH SERIES SHAFT ALIGNMENT SYSTEMS
ALIGN WITH THE BEST STEALTH SERIES SHAFT ALIGNMENT SYSTEMS S - 6 7 0 T W I R E L E S S 3 - A X I S Highest Accuracy in its Class Win 7/8 IP65 Rugged Tablets 9" or 10" Touchscreen Displays Patented Dual-Beam
More informationSTEALTH SERIES SHAFT ALIGNMENT SYSTEMS S T W I R E L E S S 5 - A X I S
ALIGN WITH THE BEST STEALTH SERIES SHAFT ALIGNMENT SYSTEMS S - 6 8 0 T W I R E L E S S 5 - A X I S Highest Accuracy in Industry Win 7/8 IP65 Rugged Tablets 10" Outdoor Touchscreen Display Patented Dual-Beam
More informationXT550. Intrinsically safe for potentially explosive environments. Shaft Alignment
XT550 Intrinsically safe for potentially explosive environments. Shaft Alignment THIS IS EASY ALIGNMENT HORIZONTAL PROGRAM The user interface is intuitive and guides you through the measurement process.
More informationStealth SerieS. Shaft alignment SyStemS S-680BT WIRELESS 5-AXIS
ALIGN WITH THE BEST Stealth SerieS Shaft alignment SyStemS S-680BT WIRELESS 5-AXIS Highest Accuracy in Industry IP65 Windows 8.1 Rugged Tablet 10" Touchscreen Display Patented Dual-Beam Technology Duo-Plane
More informationBMW KDS Wheel Alignment System
OPERATION INSTRUCTIONS Form 5215T, 09-04 BMW KDS Wheel Alignment System WinAlign Program Version 8.0 Copyright 2004 Hunter Engineering Company Contents 1. Getting Started... 1 1.1 Introduction... 1 1.2
More informationXT550. Intrinsically safe for potentially explosive environments. Shaft Alignment
XT550 Intrinsically safe for potentially explosive environments. Shaft Alignment THIS IS EASY ALIGNMENT HORIZONTAL PROGRAM The user interface is intuitive and guides you through the measurement process.
More informationUp to 50% of all costs related to rotating machinery breakdowns is caused by shaft misalignment
Up to 50% of all costs related to rotating machinery breakdowns is caused by shaft misalignment Shaft misalignment is responsible for up to 50% of all costs related to rotating machinery breakdowns. These
More informationWelcome to our world.
FIXTURLASER NXA Pro Welcome to our world. ble production. We have reached where we are today by having the courage to think beyond the norm and follow slightly unconven- we have become a global player
More informationXT660. Alignment system for all important steps of machine installation. Shaft Alignment
XT660 Alignment system for all important steps of machine installation. Shaft Alignment MEASUREMENT INDEPENDENCE EASY-LASER GENERATION XT Easy-Laser XT660 is the second member of our Generation XT alignment
More informationStealth SerieS. Shaft alignment SyStemS S-680T WIRELESS 5-AXIS
ALIGN WITH THE BEST Stealth SerieS Shaft alignment SyStemS S-680T WIRELESS 5-AXIS Highest Accuracy in Industry IP65 Windows 8.1 Rugged Tablet 10" Outdoor Touchscreen Displays Patented Dual-Beam Technology
More informationWelcome to our world.
FIXTURLASER NXA Pro Welcome to our world. Since the very beginning in 1984, ACOEM AB has helped industries throughout the world to achieve more profitable and sustainable production. We have reached where
More informationWireless Cold Clearance Measurement System For Power Plant Turbines
USER MANUAL Wireless Cold Clearance Measurement System For Power Plant Turbines Model CMS-3000 Serial Nos. PHILTEC www.philtec.com Fiberoptic Sensors for the Measurement of Distance, Displacement and Vibration
More informationTABLE OF CONTENTS TABLE OF CONTENTS... 1 IMPORTANT SAFETY NOTICE...
TABLE OF CONTENTS TABLE OF CONTENTS... 1 IMPORTANT SAFETY NOTICE... 2 1.0 General Information... 3 1.1 System Components... 3 1.2 Specifications... 3 1.2.1 Torque Ranges... 3 1.2.2 Electrical Specifications...
More informationSTEALTH SERIES TM S T WIRELESS 5 -AXIS SHAFT ALIGNMENT SYSTEMS
ALIGN WITH THE BEST STEALTH SERIES TM SHAFT ALIGNMENT SYSTEMS S - 6 8 0 T WIRELESS 5 -AXIS Highest Accuracy in Industry Win 7/8 IP65 Rugged Tablets 10" Outdoor Touchscreen Display Patented Dual-BeamTM
More informationUSER MANUAL. Turbine Blade Tip-to-Casing Cold Clearance. Wireless Measurement Kit CMS Model
USER MANUAL Turbine Blade Tip-to-Casing Cold Clearance Wireless Measurement Kit Model CMS-3400 PHILTEC 1 www.philtec.com Fiber Optic Sensors for the Measurement of Distance, Displacement and Vibration
More informationHigh-End System Accuracy at Entry-Level Pricing Windows Rugged Industrial Tablets 8 & 10 Touchscreen Displays Innovative Dual-Fan Technology Any
High-End System Accuracy at Entry-Level Pricing Windows Rugged Industrial Tablets 8 & 10 Touchscreen Displays Innovative Dual-Fan Technology Any Point Live Move Screen Embedded Bluetooth Class II IP67
More informationHigh-End System Accuracy at Entry-Level Pricing Windows Rugged Industrial Tablets 8 & 10 Touchscreen Displays Innovative Dual-Fan Technology Any
High-End System Accuracy at Entry-Level Pricing Windows Rugged Industrial Tablets 8 & 10 Touchscreen Displays Innovative Dual-Fan Technology Any Point Live Move Screen Embedded Bluetooth Class II IP67
More informationXT660. Alignment system for all important steps of machine installation. Shaft Alignment
XT660 Alignment system for all important steps of machine installation. Shaft Alignment MEASUREMENT INDEPENDENCE EASY-LASER GENERATION XT Easy-Laser XT660 is the second member of our Generation XT alignment
More informationSHAFTALIGN Redefining the standard of laser shaft alignment
SHAFTALIGN Redefining the standard of laser shaft alignment More than fourty years of experience in precision shaft alignment For over four decades, PRÜFTECHNIK Alignment Systems has continued to develop
More informationSKF Shaft Alignment Tool TKSA 31
SKF Shaft Alignment Tool TKSA 31 SKF Maintenance Products April 2015 E&OE SKF Shaft Alignment Tool TKSA 31 The intuitive and affordable laser shaft alignment system. Slide 3 Introduction of the TKSA 31
More informationXT660. Alignment system for all important steps of machine installation. Shaft Alignment
XT660 Alignment system for all important steps of machine installation. Shaft Alignment MEASUREMENT INDEPENDENCE EASY-LASER GENERATION XT Easy-Laser XT660 is the second member of our Generation XT alignment
More informationЗАО «БЕРГ АБ», (495) , Intrinsically safe shaft alignment tool with printer
Intrinsically safe shaft alignment tool with printer Intrinsically safe shaft alignment tool with printer TMEA 1PEx Application Perfect alignment of machinery shafts is crucial to prevent premature bearing
More informationDEFLECTION AND TWIST MEASUREMENT SYSTEM (DTMS) Model 47
Features DEFLECTION AND TWIST MEASUREMENT SYSTEM (DTMS) Model 47 Results are not affected by the motion or acceleration of the structure being tested Three or five degrees of freedom are measured between
More informationfrom P.R.Engineering Ltd Tel:
Quick Start FRE-205 INSTRUCTIONS from P.R.Engineering Ltd www.laser-level.co.uk Tel: 01246 269 777 Thank you for purchasing the FRE-205 Auto Rotary laser level kit. These instructions are intended to explain
More informationStealth SerieS. Shaft alignment SyStemS S-660CRT & S-660T WIRELESS 3-AXIS
ALIGN WITH THE BEST Stealth SerieS Shaft alignment SyStemS S-660CRT & S-660T WIRELESS 3-AXIS High-End System Accuracy at Entry-Level Pricing Windows 7/8 Rugged Industrial Tablets 8" & 10" Touchscreen Displays
More informationNavigator II INstallatIoN MaNUal For static and PaN/tIlt configurations
Navigator II Installation MANUAL For Static and Pan/Tilt Configurations Document Number: 432-0001-00-12, rev 100 FLIR Systems, Inc., 2008. All rights reserved worldwide. No parts of this manual, in whole
More informationPortable equipment N130/N330 QUICK GUIDE BASIC OPERATIONS
Portable equipment N130/N330 QUICK GUIDE BASIC OPERATIONS Instruments overview N330 Ports for sensors, power supply and USB CONNECTION PORTS 5 4 3 2 1 Connector 1: sensor Channel A input Connector 2: sensor
More informationUsing the Android teach-pad
with ROBWIN 7 and ROBOFORTH II v15/16 Components The components of the system are: 7 inch hand-held tablet Android software (apk or app ) already loaded. Bluetooth adaptor Serial port on rear of controller
More informationFixturlaser SMC Balancer. QUICK TIPS Fixturlaser SMC BALANCER
QUICK TIPS Fixturlaser SMC BALANCER Products FIXTURLASER SMC DU ACCELEROMETERS 2 ASH accelerometers 2 straight cables for ASH 2 high-power magnets for ASH Fixturlaser SMC Trap For connectors (USB, power
More informationBasic Modeling 1 Tekla Structures 12.0 Basic Training September 19, 2006
Tekla Structures 12.0 Basic Training September 19, 2006 Copyright 2006 Tekla Corporation Contents Contents 3 1 5 1.1 Start Tekla Structures 6 1.2 Create a New Model BasicModel1 7 1.3 Create Grids 10 1.4
More informationSHAFTALIGN OS3 The efficiency of laser shaft alignment
SHAFTALIGN OS3 The efficiency of laser shaft alignment Thirty years laser shaft alignment Precision shaft alignment pays back Precision shaft alignment extends machine uptime. It contributes in more than
More informationROTALIGN Ultra is The Alignment intelligent System
ROTALIGN Ultra is The Alignment intelligent System We care about your assets Present in all industries PRÜFTECHNIK Alignment Systems, the inventor of laser alignment, has many decades experience developing,
More informationSYSTEM WORLD PRODUCT INFO
SYSTEM WORLD PRODUCT INFO August 208 System case.. System Case Configuration.. Width x depth x height (inches).56 x 0.62 x 3.3 inches Number of System Boxes Material Lid Type Art. No. Empty* ABS Black
More informationBND TechSource. Ergonomic Manikin Manipulation using CATIA V5 DMU Kinematics. (Steps 5-11 the optimized solution)
Ergonomic Manikin Manipulation using CATIA V5 DMU Kinematics (Steps 5-11 the optimized solution) In the previous example, we showed a simple solution to manipulate an Ergonomic Manikin using CATIA DMU
More informationSKF TKSA 51. Instructions for use
SKF TKSA 51 Instructions for use Table of contents EC Declaration of conformity...2 Safety recommendations...3 1. Introduction...4 1.1 Shaft alignment overview... 4 1.2 Principle of operation... 5 1.3
More informationScanner 2000 microefm QuickStart. Installing the Scanner Remote Mount. Direct Mount NUFLO. Part No , Rev. A
NUFLO Part No. 30165024, Rev. A Scanner 2000 microefm QuickStart Installing the Scanner 2000 H L H L Flow Direct Mount To install the Scanner 2000 microefm using a direct mount to an orifice or cone meter
More informationFixturlaser SMC Supervisor QUICK TIPS. Fixturlaser SMC
QUICK TIPS Fixturlaser SMC Products FIXTURLASER SMC WIRELESS SENSOR Protection of the USB input Fixturlaser SMC Trap For connectors (USB, power supply, Ethernet...) USB Cable for the wireless sensor (power
More informationmedemagroup Joystick DX2 User guide P Q ver October 2011
medemagroup P9-0290-Q ver. 1.0.2 - October 2011 GB User guide Joystick DX2 Quick guide P9-0290-Q 2 of 16 Version 1.0.2/2011 Contents Introduction...4 Joystick parts...5 Operating...5 Clock on/off...6 Set
More informationQUICK START HAWK BALANCER. NOT3052 November 2014 A
QUICK START HAWK BALANCER www.acoemgroup.com NOT0 November 0 A Products HAWK MEASUREMENT KIT Accelerometers ASH accelerometers straight cables for ASH high-power magnets for ASH HAWK Trap for connectors
More informationAg Leader Technology Insight. Direct Command Installation Spra-Coupe 7000 Series
Note: Indented items indicate parts included in an assembly listed above. Part Name / Description Part Number Quantity Direct Command Spra-Coupe 7000 Kit 4100531 1 Liquid Product Control Module 4000394
More informationGCI-5K INSTALLATION AND OPERATOR S MANUAL
GCI-5K INSTALLATION AND OPERATOR S MANUAL Grid-tied inverter for wind Ningbo Ginlong Technologies 1 INTRODUCTION 2 SAFETY GUIDELINES AND WARNINGS 3 INSTALLATION 3.1 Selecting a location for the inverter
More informationOPTALIGN smart RS The Real Sense in machinery alignment
OPTALIGN smart RS The Real Sense in machinery alignment Many decades of experience in precision shaft alignment PRÜFTECHNIK Alignment Systems, the inventor of laser alignment, has many decades experience
More informationOPTALIGN smart RS5 The power of precision shaft alignment
OPTALIGN smart RS5 The power of precision shaft alignment Always one step ahead with precision shaft alignment RS5 technology 5-axis XL HD PSD Precision built-in inclinometer Ambient light compensation
More informationOPTALIGN smart RS5 The power of precision shaft alignment
OPTALIGN smart RS5 The power of precision shaft alignment Always one step ahead with precision shaft alignment RS5 technology 5-axis XL HD PSD Precision built-in inclinometer Ambient light compensation
More informationBore Alignment. Extruder Alignment. Application Notes
Bore Alignment Application Notes Extruder Alignment System Recommendations L-705 Laser Borescope for Extruders L-700 Twin Barrel Extruder Alignment System The L-705 Laser Borescope Alignment System In
More informationE710 / E720. Machine Alignment and Installation THE TOTAL ALIGNMENT SOLUTION. E710 / E720
www.easylaser.com E710 / E720 Machine Alignment and Installation Laser shaft alignment systems for all important steps of machine installation. TM THE TOTAL ALIGNMENT SOLUTION E710 / E720 A PRECISION CHOICE
More informationSentinel PRESS BRAKE GUARDING SYSTEM
Sentinel PRESS BRAKE GUARDING SYSTEM Sentinel Sentinel is an advanced press brake guarding system designed for retrofit applications. Sentinel provides the highest level of operator protection while maintaining
More informationO T Rotating Laser Target System.
O T - 0 0 Rotating Laser Target System. The OT-00. Portable, Accurate Measurement. The OT-00 Rotating Laser Target System, in tandem with a rotating laser, provides the fastest, most accurate way to measure
More informationFITTING TOOL SET BETEX IMPACT 33. Part No.: TB-FT
FITTING TOOL SET BETEX IMPACT 33 For safe, precise and quick mounting of bearings, bushings, sealing rings, cam wheels and pulleys the use of an Impact fitting tool set is an absolute necessity. Specially
More informationCHAPTER 3B: ELECTRONIC POWER STEERING
Electronic Power Steering CHAPTER 3B: ELECTRONIC POWER STEERING NOTE: The basic steering system, such as the tie rod ends, drag links axles, etc., is covered in Chapter 3A: Steering. In 2012, Cub Cadet
More informationOPTALIGN smart EX Maintaining high standards in machinery alignment
OPTALIGN smart EX Maintaining high standards in machinery alignment Expertise in precision laser alignment For over three decades, PRÜFTECHNIK Alignment Systems has continued to develop undisputed precision
More informationSmart Door Lock. Set-Up Guide
Smart Door Lock Set-Up Guide Thanks for choosing Rogers Smart Home Monitoring! Once you ve set-up your Smart Door Lock, the lock will allow keyless entry without sacrificing any safety. Its Touchpad makes
More informationTwo-door Access Controller
Two-door Access Controller Quick Start Guide V1.0.0 Preface Overview This document elaborates on structure, installation, interface and wiring of two-door access controller. Symbol Definition The following
More informationWiring Instructions. Gatekeeper h4.0. Technical Support.
Wiring Instructions Gatekeeper h4.0 Technical Support support@gymmastersoftware.com USA: 415 678 1270 Australia: 03 9111 0323 : 03 974 9169 Copyright 2016 Treshna Enterprises. All rights reserved. Table
More informationProduct Information. RCN 6000 Absolute Angle Encoder with Integral Bearing and Large Hollow Shaft
Product Information RCN 6000 Absolute Angle Encoder with Integral Bearing and Large Hollow Shaft 08/2018 RCN 6000 series Absolute angle encoder with Integrated stator coupling Hollow through shaft 180
More informationflipit SFI & IFI Computer Desks
Prepared for Princess Noura Bint Abdul Rahman University A S S E M B L Y I N S T R U C T I O N S flipit SFI & IFI Computer Desks SFI-352730-K19 FI Series Student Desk flipit US Patent No. 7,784,412 www.smartdesks.com
More informationBG 240. Spare parts list. Trowel. Valid from serial number Atlas Copco Construction Tools AB No c
BG 0 Spare parts list Trowel BG0 HSQP BG0 HSQP BG0 HSTP BG0 HSTP Valid from serial number BGB00000 BGB00000 BGF000000 BGF000000 0 Atlas Copco Construction Tools AB No. 900 0 0c 00 BG 0 Contents Contents
More informationUltraRack. Advanced Data Centre Enclosures SR SERIES
UltraRack Advanced Data Centre Enclosures SR SERIES Designed for scaleable growth The SR Series UltraRack SR Series - Universal rack enclosure solutions for advanced storage, cooling, power distribution,
More informationERC Quick Start Guide
ERC Quick Start Guide 1. Parts Confirmation Please contact your sales representative if any of these parts are missing or incorrect: - ERC Actuator: Slider type (ERC-SA6/SA7) or (ERC-RA54/RA64) - Relay
More informationSHAFT ALIGNMENT SYSTEM
1 2 Table of Contents LASE-A-LIGN Shaft Alignment System Packages...4 LASE-A-LIGN Shaft Alignment System package 89373458...4 Safety Notes...6 Operating information...7 LASE-A-LIGN Shaft Alignment System
More informationROTALIGN Ultra. Highest standards in machinery shaft alignment
ROTALIGN Ultra Highest standards in machinery shaft alignment Highest standards in machinery shaft alignment Present in all industries We care about your assets PRÜFTECHNIK Alignment Systems, the inventor
More informationDIGITAL BATTERY TORQUE WRENCH (DB-RAD) USER GUIDE
DIGITAL BATTERY TORQUE WRENCH (DB-RAD) USER GUIDE Ref: WCOI.094 Date: August 2017 Issue: 5 Page Description CONTENTS 1 Introduction 2 Training Requirements General Safety 3 Battery Pack Safety DB-RAD Wrench
More informationWork with RSS Feeds. Procedures. Add an RSS Text Object CHAPTER. Procedures, page 7-1
CHAPTER 7 Revised: November 15, 2011 s, page 7-1 s Add an RSS Text Object, page 7-1 Rename an RSS Text Object, page 7-2 Delete or Restore an RSS Text Object, page 7-4 Manipulate an RSS Text Object, page
More informationOFP401P0189. Color Sensor. Operating Instructions
OFP401P0189 Color Sensor Operating Instructions Last update: 23 May 2013 2 Table of contents 1. Proper Use 4 2. Safety Precautions 4 3. EC Declaration of Conformity 4 4. Technical Data 5 4.1. Connection
More informationEPS 06 in rear housing type A1
Field Installation and / or Replacement of RACO Electronic Position Sensor Board EPS 02 & EPS 06 - Electronic Limit Switches - Analog Output Position Signal - Very Accurate - Easy To Use - Robust - Dependable
More informationUltra short throw lens installation
Ultra short throw lens installation The ultra short throw lens 0.36 UST GS (P/N: 140-133108-XX) allows you to position your projector as close as possible to your screen or display. Unless otherwise indicated,
More informationD45 System. Digital colour entrance panel with addresses list
D45 System Digital colour entrance panel Description Front view D45 System entrance panel with colour camera and backlighted alphanumeric keyboard equipped with pushbutton to direct calls to the porter
More informationTurbine Controller Integration
Turbine Controller Integration Turbine Model: GE 1.5 SLE Overview The BlueScout Optical Control System (OCS) is designed to improve turbine performance by enhancing alignment of the turbine with approaching
More informationBRx6 Sensor Calibration Using SurvCE/SurvPC
OVERVIEW BRx6 Sensor Calibration Using SurvCE/SurvPC The BRx6 internal sensors (tilt, accelerometer and compass) must be calibrated in order to use the electronic bubble and tilted pole corrections in
More informationWizard PDS. Automated Perimeter Definition System. January Education and Training Center Wizard Date 5/4/2016. Page 1
PDS Automated Perimeter Definition System January 2016 Page 1 Table of Contents Information Page 3 O Page 32 Operating Procedures Basic Operation Manually Reposition a Truss Snap to Rail Centerline Flip
More information1. Home Multiple print head XY calibration manual Downloading the XY calibration file Printing the XY calibration
Home..................................................................................................... 2 Multiple print head XY calibration manual.........................................................................
More informationMultimedia web page Board
Page where the users have a space (board) to create their own compositions with graphics and texts previously inserted by the author; furthermore, the users will be able to write their own texts: Multimedia
More informationINSTRUCTION. Motor operation device NM for NAL and NALF switch/switch fuse disconnector Designed for remote control.
INSTRUCTION Motor operation device NM 24...220 for NAL and NALF switch/switch fuse disconnector Designed for remote control. Contents 1. General... 1 2. Function... 1 3. Technical data... 1 4. Mounting...
More informationTABLE OF CONTENTS SECTION 1 TABLETOP CONFIGURATION SECTION 2 TABLETOP CONFIGURATION ACCESSORIES SECTION 3 SLIDE CONFIGURATION
S6 USER S MANUAL TABLE OF CONTENTS SECTION 1 TABLETOP CONFIGURATION SECTION 2 TABLETOP CONFIGURATION ACCESSORIES SECTION 3 SLIDE CONFIGURATION SECTION 4 SLIDE CONFIGURATION ACCESSORIES SECTION 5 RACK MOUNT
More informationLABEL MATRIX TEKLYNX V E R S I O N 8 Q U I C K S T A R T G U I D E
TEKLYNX LABEL MATRIX V E R S I O N 8 Q U I C K S T A R T G U I D E Note Quick Start Guide The information in this manual is not binding and may be modified without prior notice. Supply of the software
More informationContents. - i - Ver.:2
Contents 1 Accessories of D-Point 2... 2 2 Connecting Projector to PC... 4 3 Pen Action... 4 4 Driver Installation... 5 5 Configuration Setting... 8 6 D-Point 2 Pull-up Menu... 12 7 DT02 Multi-touch Interactive
More informationFurther Information can be found at
Below is a step by step guide to assembling the Hurricane-Rig. Remember that this is a precision optical instrument. Excessive force can bend critical parts. If treated well it should give many years of
More informationDesign a Simple Fan in 123D Design
Design a Simple Fan in 123D Design Learn to use 123D Design to make and print this simple fan. 123D Design is a free, powerful, yet simple 3D creation and editing tool. It allows you to design and build
More informationSafety light beam Spot
Safety light beam is a light beam mainly used for body detection. It consists of a transmitter and a receiver. Infrared light is sent from the transmitter to the receiver and when the light beam is interrupted
More informationMOSS-DVR-810 Mobile Digital SD Recorder User Manual
MOSS-DVR-810 Mobile Digital SD Recorder User Manual Before installing and using, be sure to read this Manual for best performance. ATTENTION This product is to be used within the vehicle interior. In order
More information