The most advanced communication gateway solutions for the integration of systems
|
|
- Lora Rogers
- 6 years ago
- Views:
Transcription
1 > Portfolio 2014 The most advanced communication gateway solutions for the integration of systems
2 BACNET ASCII ENOCEAN OPC
3 ME-AC--1-V2 ME-AC--1i ME-AC--15/100 DK-AC--1 DK-AC--1i DK-RC--1 (Domestic line / Mr.Slim / City Multi*) (Domestic line / Mr.Slim / City Multi*) (City Multi) (Domestic line) (Domestic line) (SKY/VRV line) Virtual temperature Virtual temperature 15, 100 A.C. s Virtual temperature 59 x 36 x 21 mm 59 x 45 x 21 mm G-50A/GB-50A/ AG-150A/GB-50ADA S2 59 x 36 x 21 mm S2 59 x 45 x 21 mm P1/P2 Bus A.C. MH-RC--1i MH-AC--48/128 PA-AC--1i PA-RC--1i PA-RC2--1i PA-AC--64/128 Mitsubishi Heavy (FD, KX6, KXR6) X/Y Bus A.C. Mitsubishi Heavy (Superlink I&II) Virtual temperature 48, 128 A.C. s VRF bus (Superlink I&II) 215 x 170 x 65 mm (Etherea line) CN-CNT A.C. 59 x 45 x 21 mm Panasonic VRF A.C. (FS, FSM) A/B Bus A.C. R1/R2 Bus A.C. 64, 128 A.C. s EIA485 (CZ-CFUNC2) PA-AW--1 AK-AC--4/8/16/64 LG-AC--4/8/16/64 LG-RC--1i MD-AC--1 FJ-RC--1i Panasonic A.W. (Aquarea) Arçelik A.C.* LG A.C.* LG A.C (Commercial & MultiV) Midea A.C. (VRF line) Fujitsu A.C.* 1 A.W. 4, 8, 16, 64 A.C. s 4, 8, 16, 64 A.C. s Cable to A.W. EIA485 (PMNFP14A1 or PHNFP14A0) EIA485 (PMNFP14A1 or PHNFP14A0) BYR Bus A.C. CN9 & CN20 A.C. 59 x 36 x 21 mm RWB Bus A.C. * Check compatibility list with the A.C. models.
4 SM-AC--4/8/16/64/128 HI-AW--1 TO-RC--1i TO-AC--16/64 IBOX--AIRZONE IBOX-- Samsung A.C.* Hitachi A.W. (Yutaki series) Toshiba A.C. (Digital & VRF line) Toshiba A.C. (VRF line) Airzone 29V DC, 6mA 100 to 240Vac (50 to 60Hz) 4, 8, 16, 64, 128 A.C. s 1 A.W. 16, 64 A.C. s 4 CS and 32 zones per system 100, 500 or 4000 points Samsung EIA485 (MIM-B04A, MIM-B13x) Hitachi H-Link A/B Bus A.C. TCC-LINK bus 216 x 146,3 x 89,6 mm Airzone EIA485 IBOX--MBRTU IBOX--MBTCP IBOX--BAC IBOX--DSC4020 IBOX--ENO-A1 / C RTU Master TCP Master BACnet/IP Client DSC MAXSYS PC4020 EnOcean Internal LCD 100, 500 or 3000 points 100, 500 or 3000 points 100, 500 or 4000 points Up to 16 zones 32 channels / 5 devices per channel (plugin) EIA232 or EIA485 Ethernet (Ethernet) DSC MAXSYS Data Interface Module PC4401 ME-AC-MBS-1 / ME-AC-MBS-1-2I1O (Domestic line / Mr.Slim / City Multi*) 2 x DI + 1 x DO (2I1O) ME-AC-MBS-50/100 (City Multi) 50, 100 A.C. s EIA232/EIA485 and/or TCP / G-50A/GB-50A/AG-150A/ GB-50ADA * Check compatibility list with the A.C. models. MH-RC-MBS-1 Mitsubishi Heavy (FD, KX6, KXR6) X/Y Bus A.C. MH-AC-MBS-48/128 Mitsubishi Heavy (Superlink I&II) 230 Vac 48, 128 A.C. s EIA232/EIA485 Bus VRF (Superlink I & II) 215 x 170 x 65 mm LG-RC-MBS-1 LG A.C. (Commercial & MultiV) BYR bus A.C. DK-AC-MBS-1 (Domestic line) S2
5 DK-RC-MBS-1 FJ-RC-MBS-1 TO-RC-MBS-1 PA-AW-MBS-1 PA-RC2-MBS-1 PA-AC-MBS-1 PA-AC-MBS-64/128 (SKY/VRV line) Fujitsu A.C.* Toshiba A.C. (Digital & VRF line) Panasonic A.W. (Aquarea) (Etherea line) 1 A.W. 64, 128 A.C. s P1/P2 Bus A.C. RWB Bus A.C. indoor unit A/B Bus A.C. Cable to A.W. indoor unit R1/R2 Bus A.C. CN/CNT A.C. indoor unit EIA232/EIA485 and/or TCP / Panasonic EIA485 (CZ-CFUNC2) SM-AC-MBS- 4/8/16/64/128 IBOX-MBS-MBUS IBOX-MBS- IBOX-MBS-BAC IBOX-MBS-BACMSTP IBOX-MBS- Samsung A.C.* MBUS Client BACnet/MSTP 4, 8, 16, 64, 128 A.C. s 100, 600 or 2000 signals and 10, 60 or 500 devices 100, 500 or 3000 control points Up to 100, 500 or 3000 control points 100, 500 or 3000 control points 100, 500 or 3000 control points EIA232/EIA485 and/or TCP / Samsung EIA485 (MIM-B04A, MIM-B13x) EIA232/EIA485 MBUS EIA232/EIA485 EIA232/EIA485 EIA232/EIA485 (Ethernet) EIA232/EIA485 BACnet EIA485 EIA232/ EIA485 SOLAR PANELS IBOX-MBS-ATERSA - ATERSA - Up to 99 devices FIRE PANELS IBOX-MBS-CERBERUS - SIEMENS - Cerberus CS11 and CS10 with ISO 1745 protocol IBOX-MBS-FC330A - SIEMENS - Synova FC330A IBOX-MBS-DALI IBOX-MBS-FIDELIO IBOX-MBS-TCP2RTU IBOX-MBS-4SLAVE IBOX-MBS-ALGOREX - SIEMENS - Algorex DALI 230Vac 64 ballasts and 16 DALI groups EIA232/ EIA485 Bus DALI (2 cables) DIN-Rail 9 modules FIDELIO IP Check in/out for up to 1500 rooms EIA232/EIA485 Fidelio IP TCP Server - RTU Master 254 RTU Slave / 32 TCP Master EIA232/EIA485 TCP Up to 4 Masters Master: 2 RTU and 2 TCP EIA232/EIA485 TCP IBOX-MBS-ALGORI - ADEMCO - Algorinet BC216 IBOX-MBS-EDP-3/6/9 - ESSER - 8xxx/IQ8/FlexES IBOX-MBS-KILSEN - KILSEN - KSA 7XX IBOX-MBS-ZITON - ZITON - ZP3 and ZP5 IBOX-MBS-NID NOTIFIER - ID3000, ID3002 IBOX-MBS-ID2NET - NOTIFIER - Up to 64 fire panels Notifier ID3000 in ID2NET network IBOX-MBS-XLS80 - HONEYWELL - XLS-80 SECURITY PANELS IBOX-MBS-GALAXY - HONEYWELL - Galaxy * Check compatibility list with the A.C. models.
6 BACNET PA-AC-BAC-64/128 PA-AC-BAC-1 PA-RC2-BAC-1 IBOX-BAC- IBOX-BAC-MBRTU IBOX-BAC-MBTCP (Etherea line) RTU TCP 64, 128 A.C. s 100, 500 or 3000 control points 100, 500 or 3000 control points / 254 RTU slaves 100, 500 or 3000 control points / 5 RTU slaves EIA485 (CZ-CFUNC2) BACnet objects CN/CNT A.C. BACnet objects R1/R2 Bus A.C. EIA232/EIA485 o TCP TCP BACNET IBOX-BAC- IBOX-BAC-FIDELIO_IP IBOX-BAC-MBUS IBOX-BAC-DALI IBOX-BAC-SUNWAYS IBOX-BAC-NID3000 Fidelio IP MBUS DALI SUNWAYS Notifier ID , 500 or 3000 control points / 128 devices Check in/out for up to 1500 rooms 100, 600 or 2000 signals and 10, 60 or 500 devices 230Vac 64 ballasts and 16 groups DALI 32 devices Compatible with ID3000, ID3002 Fidelio IP MBUS EIA232/EIA485 Bus DALI (2 wire) SUNWAYS EIA485 Notifier EIA232 DIN-Rail 9 modules ASCII ME-AC--1 (Domestic line / Mr.Slim / City Multi)* IBOX-- PANURBAN * IBOX-- IBOX-ASCII- IBOX-ASCII- IBOX-ASCII-BAC BACnet LonWorks compatible tool 1221 network variables LonWorks compatible tool 200, 500 or 4000 points LinkBox 4000 Control points 500 or 4000 points and 64 or 128 devices LinkBoxASCII 500 or 4000 points and 64 BACnet/IP devices PANASONIC CZ-01FULAP (EIA232) DIN-Rail 9 modules DIN-Rail 9 modules ASCII EIA232 ASCII EIA232 ASCII EIA232 BACnet/IP * Check compatibility list with the A.C. models.
7 ENOCEAN ME-AC-ENO-1 / 1C MH-RC-ENO-1i / 1iC DK-AC-ENO-1 / 1C DK-RC-ENO-1i / 1iC PA-AC-ENO-1i / 1iC (Domestic line / Mr.Slim / City Multi)* Mitusbishi Heavy (FD, KX6, KXR6) (Domestic line) (SKY/VRV line) (Etherea line) Repeater functionality Repeater functionality Communitacion X/Y Bus A.C. S2 P1/P2 Bus A.C. CN-CNT A.C. ENOCEAN USB-ENO / C USB-ENO-ASCII / C USB-ENO-ASCII-U / C IS-TK04 / C IS-TK65 / C USB IntesisBox gateways for A.C. ASCII Universal Room controller and temperature sensor Wireless external temperature sensor (USB) (USB) (USB) (Solar panel) (Solar panel) ESP2 and ESP3 compatible Repeater functionality Control through ASCII Repeater functionality ASCII BMS integration On/Off Setpoint and ambient temperature Fan speed External temperature sensor Unlimited sensors / 128 actuators Up to 10 gateways for A.C. 99 Rx channels / 128 Tx Ambient temperature range: 0 C +40 C Ambient temperature range: -20 C +60 C USB USB USB 84,5 x 84,5 x 25 mm 78 x 58 x 45,5 mm OPC IS-OPC-NID3K IS-OPC-ESSER OPC Server for Notifier ID3000 Series OPC Server for ESSER 8007/8008/IQ8 OPC 1.0a and 2.0 specification Unlimited panels OPC 1.0a and 2.0 specification * Check compatibility list with the A.C. models.
8 C/ Milà i Fontanals, 1 bis 1º Igualada - Barcelona - Spain Follow us: intesissoftware Authorized Dealer Intesis Software is member of the Association, Spain and EnOcean Alliance 2014 Intesis Software S.L. All rights reserved IntesisBox is a registered trademark of Intesis Software SL The information in this document is subject to change without notice. All trademarks and tradenames used in this document are acknowledged to be the copyright of their respective holders.
Portfolio. The most advanced communication gateway solutions for the integration of systems
> Portfolio The most advanced communication gateway solutions for the integration of systems BACNET ASCII ENOCEAN OPC ME-AC--1-V2 ME-AC--1i ME-AC--15/100 DK-AC--1 DK-AC--1i (Domestic line / Mr.Slim / City
More informationGeneral catalogue 2013
IntesisBox your partner for systems integration INTERIOR PORTADA General catalogue 2013 KNX MODBUS BACNET LONWORKS ENOCEAN ASCII OPC SERVER Intesis Software S.L. C/ Milà i Fontanals, 1 bis 1º 08700 Igualada
More informationIntesisBox. for EnOcean
IntesisBox for EnOcean your partner for systems integration INTERIOR PORTADA General catalogue 2013 KNX MODBUS BACNET LONWORKS ASCII OPC SERVER Intesis Software S.L. C/ Milà i Fontanals, 1 bis 1º 08700
More informationDK-AC-KNX-1. Specifications. Main features. Info
IntesisBox 2015 DK-AC-KNX-1 IntesisBox DK-AC-KNX-1 allows monitoring and control, fully bi-directionally, all the operational parameters of DAIKIN air conditioners from KNX installations. Compatible with
More informationIntesisBox. Making Building Automation go further. LON Products
IntesisBox Making Building Automation go further 2009 Intesis Software S.L. All rights reserved. IntesisBox is a registered trademark of Intesis Software SL.. All trademarks and tradenames used in this
More informationIntesisBox. Making Building Automation go further. BACnet Products
IntesisBox Making Building Automation go further 2009 Intesis Software S.L. All rights reserved. IntesisBox is a registered trademark of Intesis Software SL.. All trademarks and tradenames used in this
More informationIntesisBox Modbus Server LG Air Conditioning. User s Manual Issue Date: 06/2016 r1 eng
IntesisBox Modbus Server LG Air Conditioning User s Manual Issue Date: 06/2016 r1 eng Intesis Software S.L. 2016 All Rights Reserved. Information in this document is subject to change without notice. The
More informationIntesisBox Modbus Server KILSEN KSA-7xx. User s Manual 08/2013 r1.2 eng
IntesisBox Modbus Server KILSEN KSA-7xx User s Manual 08/2013 r1.2 eng Intesis Software S.L. 2013 All rights reserved. Information in this document is subject to change without notice. The software described
More informationAll roads lead to IntesisBox
M ULTI A DDRESSING P OINTS S OLUTION All roads lead to IntesisBox IntesisBox MAPS is a Windows compatible software tool developed specifically to monitor and configure the new generation of IntesisBox
More informationInnovative Solutions for home & building automation. June 2009
Innovative Solutions for home & building automation June 2009 W h o w e a r e Leading providers of interfacing solutions for systems integration Specifically designed for building and home automation Own
More informationIntesisBox Modbus Server Fidelio IP
IntesisBox Modbus Server Fidelio IP User Manual r1 eng Issue Date: 10/04/2014 Intesis Software S.L. All Rights Reserved. Information in this document is subject to change without notice. The software described
More informationIntesisBox PA-AW-MBS-1 v.2.0
IntesisBox PA-AW-MBS-1 v.2.0 Modbus RTU (EIA485) Interface for Panasonic Aquarea series. User Manual Issue Date: 08/2014 r2.0 Order Code: PA-AW-MBS-1: Modbus RTU Interface for Panasonic Aquarea series
More informationIntesisBox Modbus Server Siemens Synova FC330A
IntesisBox Modbus Server Siemens Synova FC330A User's Manual V10 r10 eng Intesis Software S.L. 2009. All Rights Reserved. Information in this document is subject to change without notice. The software
More informationAIR CONDITIONER. UNIVERSAL - More than 5O A.C brands SPECIFIC. - Mitsubishi Electric. - Daikin - Panasonic - LG. - Midea
I K X M D U S IR DIIR UIVRSL - More than 5. brands SPIFI - Mitsubishi lectric - LG - Midea - Hitachi - Samsung - Fujitsu - Haier - Hisense IR DIIR - Mitsubishi lectric - LG - Samsung - Fujitsu - Hisense
More informationIntesisBox Modbus Server Panasonic
IntesisBox Modbus Server - Panasonic Gateway for Panasonic ECO-i VRF and PAC-i system integration into Modbus Systems Master Up to 30 Outdoor units Up to 64 Indoor units Modbus TCP Master /EIA232 PA-AC-MBS-64/128
More informationIntesisBox PA-AC-MBS-1
IntesisBox PA-AC-MBS-1 v.2.3 Modbus RTU (EIA-485) Interface for Panasonic air conditioners. Compatible with Etherea line air conditioners commercialized by Panasonic. User s Manual Issue Date: 11/2017
More informationCoolMasterNet Technical Data CoolMasterNet Universal Interface Adapter for HVAC Systems
CoolMasterNet Universal Interface Adapter for HVAC Systems Document Revision 0.6 4/25/20 20 CoolAutomation LTD. Attention 1. During the HVAC system automatic operations the CoolMasterNet must be disconnected
More informationIntesisBox Modbus Server M-Bus
IntesisBox Modbus Server M-Bus User Manual r1.1 eng Issue date: 10/2017 Intesis Software S.L.U. 2017 All Rights Reserved. Information in this document is subject to change without notice. The software
More informationIntesisBox KNX. User Manual v10 r10 eng. Mitsubishi Electric air conditioners (Domestic & Mr.Slim lines) Release V.0.2
IntesisBox KNX Mitsubishi Electric air conditioners (Domestic & Mr.Slim lines) Release V.0.2 User Manual v10 r10 eng Intesis Software S.L. All Rights Reserved. Information in this document is subject to
More informationIntesisBox Modbus Server - LON
IntesisBox Server - LON Gateway for integration of LON devices into enabled control systems. Integrate Air Conditioning from the main manufacturers (DAIKIN, Mitsubishi Electric, Mitsubishi Heavy Industries,
More informationIntesisBox. v.0.1. User Manual Issue Date: 12/2017 r1.3 EN
IntesisBox HS-RC-MBS-1 v.0.1 Modbus RTU (EIA-485) Interface for Hisense air conditioners. Compatible with commercial line of air conditioners commercialized by Hisense. User Manual Issue Date: 12/2017
More informationCoolMasterNet Technical Data CoolMasterNet Universal Interface Adapter for HVAC Systems
CoolMasterNet Technical Data CoolMasterNet Universal Interface Adapter for HVAC Systems Document Revision 0.3 3/23/2015 Attention 1. During the HVAC system automatic operations the CoolMasterNet must be
More informationIBOX Modbus Server ESSER 8xxx/IQ8/FlexES fire panels
IBOX Modbus Server ESSER 8xxx/IQ8/FlexES fire panels Installation Manual r1 eng 11.2013 Cambios técnicos reservados GB ES-MN-18002-01-2 2010 Honeywell International Inc. ESSER by Honeywell. All Rights
More informationIntesisBox Modbus Server KNX
IntesisBox Modbus Server KNX User Manual r1.0 eng Issue date: 09/2017 Intesis Software S.L.U. 2017 All Rights Reserved. Information in this document is subject to change without notice. The software described
More informationIntesisBox Modbus Server BACnet MSTP and BACnet/IP client
IntesisBox Modbus Server BACnet MSTP and BACnet/IP client User Manual r1.0 EN Issue date: 04/2018 Intesis Software S.L.U. 2018 All Rights Reserved. Information in this document is subject to change without
More informationLDALI ME204-U, LDALI ME201 U
Functions BACnet/ Controller L ME204-U, L ME201 U BACnet CEA 709 Modbus OPC Datasheet #89021219 L WEB, L STUDIO L Controllers are multifunctional devices combining constant light con trol, sunblind control
More informationIntesisBox Modbus Server Mitsubishi Electric Centralized Controller TCP/IP XML. User Manual Issue Date: 01/2018 r1.0 EN
IntesisBox Modbus Server Mitsubishi Electric Centralized Controller TCP/IP XML User Manual Issue Date: 01/2018 r1.0 EN Intesis Software S.L.U. 2018 All Rights Reserved. Information in this document is
More informationModbus Server - Mitsubishi Electric G50
IntesisBox Server - Mitsubishi Electric G50 Gateway for monitor and control Mitsubishi Electric City Multi Air Conditioning systems from any master device TCP or RTU (BMS, PLC, SCADA, HMI, TouchPanel )
More informationIntesisBox BACnet/IP Server DALI
IntesisBox BACnet/IP Server - DALI Gateway for integration of DALI ballasts into BACnet/IP networks BACnet IP client BACnet/IP Ethernet DALI bus BACnet IP client LAN TCP/IP IntesisBox DALI ballasts LinkBoxBacnet
More informationIntesisBox TO-RC-MBS-1
IntesisBox TO-RC-MBS-1 v.1.5 MODBUS RTU (EIA485) Interface for Toshiba air conditioners from the Digital Inverter & VRF lines. User Manual Issue Date: 01/2014 Order Codes: TO-RC-MBS-1 Intesis Software
More informationFailure to follow WARNING is very likely to result in such grave consequences as death or serious injury
Warning Read these Safety Precautions carefully to ensure correct installation. This manual classifies precautions into WARNING and CAUTION. Failure to follow WARNING is very likely to result in such grave
More information---- IntesisBox KNX Modbus RTU Master and Modbus TCP Client
---- IntesisBox KNX Modbus RTU Master and Modbus TCP Client User Manual r1.1 eng Issue date: 05/2018 Intesis Software S.L.U. 2018 All Rights Reserved. Information in this document is subject to change
More informationModbus Server SIEMENS Algorex (printer port)
IntesisBox Server SIEMENS (printer port) Gateway for the integration of Siemens fire detection panels into enabled control systems. Monitor your fire panels remoy from your Control Center using any commercial
More informationIntesisBox Modbus Server - BACnet/IP Client
IntesisBox Modbus Server - BACnet/IP Client Gateway for integration of devices into Modbus (RTU and TCP) systems. Integrate Daikin VRV Air Conditioners into your Modbus system (SCADA, BMS, PLC ). For this,
More informationIntesisBox. v.2.5. User Manual Issue Date: 12/2017 r1.9 EN. Modbus RTU (EIA-485) Interface for Fujitsu air conditioners.
IntesisBox FJ-RC-MBS-1 v.2.5 Modbus RTU (EIA-485) Interface for Fujitsu air conditioners. User Manual Issue Date: 12/2017 r1.9 EN Order Codes: FJ-RC-MBS-1: Modbus RTU Interface for Fujitsu air conditioners
More informationIntesisBox Modbus Server Hitachi VRF Air Conditioning. User Manual Issu Date: 11/2018 r1.0 EN
IntesisBox Modbus Server Hitachi VRF Air Conditioning User Manual Issu Date: 11/2018 r1.0 EN Intesis Software S.L.U. 2018 All Rights Reserved. Information in this document is subject to change without
More informationIntesisBox KNX - BACnet/IP Client
IntesisBox KNX - BACnet/IP Client Gateway for integration of BACnet/IP devices into KNX control systems. Integrate Daikin VRV Air Conditioners into your KNX system. Daikin VRV system must be equipped with
More informationIntesisBox ModBus RTU Fujitsu Air Conditioning
IntesisBox ModBus RTU Fujitsu Air Conditioning Compatible with Domestic and VRF line air conditioners commercialized by Fujitsu User Manual 03/2019 r1.0 eng Intesis Software S.L.U. 2019 All Rights Reserved.
More informationIntesisBox Modbus Server BACnet/IP Client
IntesisBox Modbus Server BACnet/IP Client User's Manual v10 r14 eng Issue date: 15/10/2012 Intesis Software S.L. 2012 All Rights Reserved. Information in this document is subject to change without notice.
More informationLDALI PLC4. Programmable DALI Controller. Functions. BACnet. DALI CEA 709 M Bus KNX OPC L WEB, L STUDIO L ROC L INX. L IOB IoT. Gateways L VIS, L-STAT
COMPETECE PARTER DAI PC4 Functions BACnet DAI CEA 709 M Bus KX OPC Datasheet #89055220 WEB, STUDIO The DAI PC4 controllers are powerful, programmable lighting controllers, which can be programmed by STUDIO.
More informationCoolPlug CooLinkHub HVAC Bridge. Quick Installation Guide
Bridge Quick Installation Guide Warning Read and understand the following Safety Guidelines and Warnings to ensure a safe installation Failure to follow WARNING may result in injury or death. This equipment
More informationIntesisBox Modbus Server - Honeywell XLS 80
IntesisBox Server - Honeywell XLS 80 Gateway for integration of Honeywell XLS 80 fire panels into (RTU and TCP) enabled control systems. Integrate your Honeywell fire panels into your master device or
More informationLDALI ME204-U, LDALI ME201 U
Functions DAI ME204-U, DAI ME201 U BACnet CEA 709 Modbus DAI OPC Datasheet #89021219 WEB, STUDIO DAI Controllers are multifunctional devices combining constant light con trol, sunblind control and gateway
More informationIntesisBox BACnet/IP Server Modbus RTU Master
IntesisBox BACnet/IP Server Modbus RTU Master User's manual Issue Date: 17/12/2012 r14 eng Intesis Software S.L. All Rights Reserved. Information in this document is subject to change without notice. The
More informationIntesisBox KNX. Mitsubishi Electric G-50A/GB-50A/GB-50ADA/AG-150A. User's Manual Issue date: 03/08/2012 r21 eng
IntesisBox KNX Mitsubishi Electric G-50A/GB-50A/GB-50ADA/AG-150A User's Manual Issue date: 03/08/2012 r21 eng Intesis Software S.L. 2012 All Rights Reserved. Information in this document is subject to
More informationIntesisBox KNX SAMSUNG NASA Air Conditioners
IntesisBox KNX SAMSUNG NASA Air Conditioners Gateway for integration of Samsung NASA air conditioners into KNX control systems. Integrate Samsung Air Conditioners into KNX. KNX/EIB bus R1/R2 EIA485 SM-ACN-KNX-4-8-16-64
More informationProcon BAC-A/50. Installation Instructions MITSUBISHI ELECTRIC
Installation Instructions Procon BAC-A/50 MITSUBISHI ELECTRIC BACnet TM is a registered trademark of ASHRAE (American Society of Heating, Refrigerating and Air- Conditioning Engineers, Inc.) 1. Product
More informationIntesisBox BACnet/IP Server Modbus TCP Master
IntesisBox BACnet/IP Server Modbus TCP Master User's manual Issue Date: 3/2018 r1.1 eng Intesis Software S.L.U. All Rights Reserved. Information in this document is subject to change without notice. The
More informationLIOB 550/551/552/553/554 V2
Functions IOB BIP I/ O Module BACnet Modbus CEA 709 M Bus KX OPC IOB 550/551/552/553/554 V2 Datasheet #027119 WEB, STUDIO The IOB 55x Modules communicate over Ethernet/ IP in the BACnet/ IP network. They
More informationInstallation Guide V1.2
+ Welcome to the Connected Home Installation Guide V1.2 MyAir Installation Guide Contents 1 - SYSTEM OVERVIEW 2 - OVERVIEW 3 - COMPATIBILITY 4 - SETUP 5 - DAIKIN ( DK) SETUP 6 - FUJITSU ( FJ) SETUP 7
More informationIntesisBox KNX - Mitsubishi Electric G50
IntesisBox KNX - Mitsubishi Electric G50 Gateway for integration of Mitsubishi Electric City Multi air conditioners into KNX control systems. Integrate Mitsubishi Electric City Multi Air Conditioning systems
More informationSafety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any
More informationUSER'S MANUAL. IntesisBox KNX K01-KNX-1B/16/64 v1.0. r1 eng Issue Date: 2014/06
USER'S MANUAL IntesisBox KNX K01-KNX-1B/16/64 v1.0 r1 eng Issue Date: 2014/06 Interface for integration of Kaysun air conditioners into KNX TP-1 (EIB) control systems. Compatible with VRF air conditioners
More informationGateway for integration of Modbus RTU slave devices into BACnet IP based systems.
IntesisBox BACnet/IP Server - RTU master Gateway for integration of RTU devices into based systems Integrate any RTU device into your BACnet control system Ethernet RS485 (can be also RS232 for single
More informationIntesisBox MAPS. Configuration & monitoring software of IntesisBox KNX series. User's manual Issue Date: 06/17 r1.0 eng
IntesisBox MAPS Configuration & monitoring software of IntesisBox KNX series User's manual Issue Date: 06/17 r1.0 eng Intesis Software S.L.U. 2017 All Rights Reserved. Information in this document is subject
More informationIntesisBox. v.1.3. User Manual Issue Date: 04/2016. IntesisBox PA-RC2-MBS-4
IntesisBox PA-RC2-MBS-4 v.1.3 MODBUS RTU (EIA485) Interface for Panasonic and Sanyo air conditioners. Compatible with ECOi and PACi line models. User Manual Issue Date: 04/2016 Order Codes: PA-RC2-MBS-4
More informationIntesisBox SMS - Mitsubishi Electric air conditioners
Order code ME-AC-SMS-32 IntesisBox SMS - Mitsubishi Electric air conditioners Controller with SMS interface for monitoring and control Mitsubishi Electric air conditioners. Control your Mitsubishi Electric
More informationControl systems for PACi, ECOi and ECO G
Control systems for PACi, ECOi and ECO G Control for hotel application (for VRF) Intelligent Controller Wired remote controller Normal operation with Econavi PAW-RE2C3-WH PAW-RE2C3-GR PAW-RE2C3-MOD-WH
More informationBUILDING MANAGEMENT. OpenBAS-HV-NX10 SERIES CATALOG NUMBER. Description. Features
BUILDING MANAGEMENT OpenBAS-HV-NX10 SERIES Description Mircom s OpenBAS-HV-NX10 series of Building Automation Controllers are aimed to provide various HVAC, energy management, and lighting control solutions
More informationSCS (System Core Server) Model BCY44100M
Specifications General SCS (System Core Server) is a controller that integrates DDC (direct digital controller) and RS (remote station), such as PARAMATRIX -III and Infilex series controllers, into BMS
More informationIntesisBox KNX - AIRZONE
IntesisBox KNX - AIRZONE Gateway for the integration of Airzone InnoBUS into KNX systems. Full integration of Airzone InnoBUS air conditioning with KNX control systems. CS CS KNX EIB Bus IntesisBox RS485
More informationPRELIMINARY. CoolMasterNet PRM. CoolMasterNet Universal Interface Adapter for HVAC Systems. Document Revision /11/2014
CoolMasterNet PRM CoolMasterNet Universal Interface Adapter for HVAC Systems Document Revision 0.4 12/11/2014 CoolMasterNet PRM Contents 2 Table of Contents 1 Document Revision History 4 2 Acronyms 5 3
More informationIntesisBox DK-RC-MBS-1 v.0.2
IntesisBox DK-RC-MBS-1 v.0.2 MODBUS RTU (RS-485) Interface for Daikin air conditioners. Compatible with VRV and SKY line air conditioners commercialized by Daikin. User Manual Issue Date: 2011/05/05 Order
More informationModbus Server - Mitsubishi Electric G50
IntesisBox Server - Mitsubishi Electric G50 Gateway for monitor and control Mitsubishi Electric City Multi Air Conditioning systems from any master device TCP or RTU (BMS, PLC, SCADA, HMI, TouchPanel )
More informationIntesisBox MAPS. Configuration & monitoring software of IntesisBox Modbus series. User's manual Issue Date: 01/18 r1.1 eng
IntesisBox MAPS Configuration & monitoring software of IntesisBox Modbus series User's manual Issue Date: 01/18 r1.1 eng Intesis Software S.L.U. 2018 All Rights Reserved. Information in this document is
More informationEfficient. Innovative. Sustainable.
Efficient. Innovative. Sustainable. Controlesta RCO System Description On-line, at each time, at each place 1 CONTROLESTA RCO System Description 1. System architecture 2.1 Master Controller 2.2 Network
More informationIntesisBox KNX Modbus TCP master
IntesisBox KNX Modbus TCP master User's Manual v10 r12 eng Intesis Software S.L. All Rights Reserved. Information in this document is subject to change without notice. The software described in this document
More informationIntesisBox KNX. BACnet/IP Client. User's Manual v10 r10 eng
IntesisBox KNX BACnet/IP Client User's Manual v10 r10 eng Intesis Software S.L. All Rights Reserved. Information in this document is subject to change without notice. The software described in this document
More information2014 / 15 CONTROLS. for TOSHIBA air conditioning applications
2014 / 15 CONTROLS for TOSHIBA air conditioning applications CONTROLS Local controls TOSHIBA offer a number of local control products that can be used to control a single indoor unit, or group of up to
More informationIntesisBox BACnet IP Server - M-Bus
IntesisBox Server - M-Bus Gateway for integration of M-Bus meters into BACnet/IP based control systems Integrate M-Bus meters into your BACnet/IP control system BACnet/IP Ethernet RS232 RS232 / RS485 to
More informationModbus RTU (EIA-485) Interface for Panasonic and Sanyo air conditioners. Compatible with ECOi and PACi line models.
IntesisBox PA-RC2-MBS-1 v.2.3 Modbus RTU (EIA-485) Interface for Panasonic and Sanyo air conditioners. Compatible with ECOi and PACi line models. User Manual Issue Date: 11/2017 r2.3 EN Order Codes: PA-RC2-MBS-1:
More informationIntesisBox DK-RC-MBS-1 v.0.8
IntesisBox DK-RC-MBS-1 v.0.8 MODBUS RTU (RS-485) Interface for Daikin air conditioners. Compatible with VRV and SKY line air conditioners commercialized by Daikin. User Manual Issue Date: 2013/02/26 Order
More informationIntesisBox BACnet/IP Server M-Bus meters
IntesisBox BACnet/IP Server M-Bus meters User's manual Issue Date: 01/2018 r14.01 eng Intesis Software S.L.U. All Rights Reserved. Information in this document is subject to change without notice. The
More informationASCII Server - BACnet/IP Client. Gateway for integration of BACnet IP devices into ASCII enabled control systems.
IntesisBox ASCII Server - BACnet/IP Client Gateway for integration of devices into ASCII enabled control systems. Integrate Daikin VRV Air Conditioners into your ASCII enabled control system (AM, Crestron,
More informationAIAS. Technical description
Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains AIAS - and Efficient Heating Demand Products Controlled Tunnel Ventilation Fans 1 / 4 AIAS Technical description 2 / 9 AIAS -
More informationIntesisBox KNX. User s Manual Issue Date: 12/07/2012 r1.2 eng. Mitsubishi Heavy Industries Air Conditioning. Order Code: MH-AC-KNX-48 MH-AC-KNX-128
IntesisBox KNX Mitsubishi Heavy Industries Air Conditioning User s Manual Issue Date: 12/07/2012 r1.2 eng Order Code: MH-AC-KNX-48 MH-AC-KNX-128 Intesis Software S.L. 2012 All Rights Reserved. Information
More informationCoolPlug CooLinkHub HVAC Bridge. Quick Installation Guide
CoolPlug CooLinkHub HVAC Bridge Quick Installation Guide Warning Read and understand the following Safety Guidelines and Warnings to ensure a safe installation Failure to follow WARNING may result in
More informationThe Simply Smart Way to Optimize Building Control and Performance
Connected Buildings ComfortPoint Open Building Management System The Simply Smart Way to Optimize Building Control and Performance For Consultants and Specifiers ComfortPoint Open BMS. Simply Smart. Honeywell
More informationIntesisBox KNX LG Air Conditioning
IntesisBox KNX LG Air Conditioning User's Manual Issue Date: 06/2018 r1.3 EN Intesis Software S.L.U. All Rights Reserved. Information in this document is subject to change without notice. The software
More informationIntesisBox ME-AC-BAC-1
IntesisBox IntesisBox BACnet MS/TP & BACnet IP Server for Mitsubishi Electric Air Conditioners (Domestic Line, Mr Slim and City Multi) BACnet BACnet Client device etc The interface allows a complete and
More informationLROC 100, LROC L ROC Room Controller. Functions. Modbus. BACnet CEA 709 KNX. M-Bus OPC L WEB L ROC L INX L VIS, L-STAT L DALI
Functions L ROC Room Controller LROC 100, LROC 101 LOYTEC COMPETENCE PARTNER BACnet CEA 709 KNX Modbus M Bus OPC Datasheet #89026118 L ROC L WEB The L ROC Room Controller provides the basis for a revolutionary
More informationWMP Protocol Specification
Issue date: 03/2017 r1.6 Intesis Software S.L.U. 2017 Intesis Software S.L.U. All rights reserved. This document has been carefully written by. and a lot of effort has been made to ensure no errors or
More informationMXB-50 BACnet Interface for Mitsubishi Air-Conditioning
MXB-50 BACnet Interface for Mitsubishi Air-Conditioning Installation and User Guide www.microtrol.co.uk BACnet TM is a registered trademark of ASHRAE (American Society of Heating, Refrigerating and Air-
More informationIntesisBox LON - KNX
IntesisBox - KNX Gateway for the integration of KNX devices into LonWorks networks KNX interface Bindings interface FB_1 Com.Obj1 nvo1 KNX (TP-1) KNX Com.Obj2 Netwo nvon nvi1 nvin (TP/FT-10) Com.ObjN FB_N
More informationIntesisBox. KNX - Mitsubishi Electric G50. Gateway for integration of Mitsubishi Electric City Multi air conditioners into KNX control systems.
IntesisBox KNX - Mitsubishi Electric G50 Gateway for integration of Mitsubishi Electric City Multi air conditioners into KNX control systems. Integrate Mitsubishi Electric City Multi Air Conditioning systems
More informationSee instructions to download and install the latest version of LinkBoxMB and the user's manual at
Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any
More informationLDALI PLC4. Programmable DALI Controller. Functions DALI. BACnet. CEA 709 M Bus KNX OPC L WEB, L STUDIO L ROC L INX L IOB IOT. Gateways L VIS, L-STAT
COMPETECE PARTER DAI PC4 Functions Programmable DAI Controller BACnet DAI CEA 709 M Bus KX OPC Datasheet #89055219 Built-In or External DAI Power Supply ROC The DAI PC4 Controller needs an external DAI
More informationR-ION Topologies R-ION TOPOLOGIES DOCUMENT. Rev H (Apr 2018)
R-ION TOPOLOGIES DOCUMENT Rev H (Apr 2018) Basic user-interface only with connecton to local controller or supervisory system (models RS2-W / RS-W) Bacnet MSTP (models RS2-S / RS-S) Modbus RTU (models
More informationBMS Interface for Panasonic Air-Conditioning
BMS Interface for Panasonic Air-Conditioning Installation and User Guide www.microtrol.co.uk BACnet TM is a registered trademark of ASHRAE (American Society of Heating, Refrigerating and Air-Conditioning
More informationControl system. Type FSL-CONTROL II. Modular, stand-alone room control system, specially for decentralised ventilation systems (with bus communication
X X testregistrierung Control system Type Central BMS interface DCP-FSL II-Stand-alone Pressure independent control valve Straight-way valve Modular, stand-alone room control system, specially for decentralised
More informationSmart Equipment Controls (SEC)
Smart Equipment Controls (SEC) Product Bulletin SE-SPU1001-0, SE-SPU1002-0, SE-SPU1011-0, SE-SPU1011-0, SE-SPU1012-0, SE-SPU1004-0, SE-FDD1001-0, SE-ECO1001-0, SE-COM1001-0 Code No. LIT-12011934 Issued
More informationSee instructions to download and install the latest version of LinkBoxMB and the user's manual at
Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any
More informationInstallation Instructions. Procon IP-32M wir-1_ MITSUBISHI ELECTRIC
Installation Instructions Procon IP-32M 2371-wir-1_2-0204 MITSUBISHI ELECTRIC Procon IP-32M Overview The Procon IP-32M unit provides an interface between a Mitsubishi City-Multi G50A controller with up
More informationnotification. Issue date: 10/2014 r2
E-mail notification Issue date: 10/2014 r2 Intesis Software S.L. 2014 Intesis Software S.L. All rights reserved. This document has been carefully written by Intesis Software SL. and a lot of effort has
More informationCOMTRAXX COM465IP. Condition Monitor with integrated gateway for the connection of Bender devices to Ethernet TCP/IP networks
Condition Monitor with integrated gateway for the connection of Bender devices to Ethernet TCP/IP networks COM465IP_D00217_04_D_XXEN/11.2018 Condition Monitor with integrated gateway for the connection
More informationCOMTRAXX COM465IP. Condition Monitor with integrated gateway for the connection of Bender devices to Ethernet TCP/IP networks
Condition Monitor with integrated gateway for the connection of Bender devices to Ethernet TCP/IP networks COM465IP_D00217_00_D_XXDE/10.2015 Condition Monitor with integrated gateway for the connection
More informationCOMTRAXX COM465DP. Condition Monitor with integrated gateway for the connection of Bender devices to PROFIBUS DP and Ethernet TCP/IP networks
Condition Monitor with integrated gateway for the connection of Bender devices to PROFIBUS DP and Ethernet TCP/IP networks COM465DP_D00216_00_D_XXDE/10.2015 Condition Monitor with integrated gateway for
More informationTX-I/O Product Range. Description. Technical Specification Sheet Document No July 18, 2013
Technical Specification Sheet Document No. 149-476 July 18, 2013 TX-I/O Product Range TX-I/O is a range of I/O modules, with associated power and communication modules, for use within the APOGEE Automation
More informationPRODUCT UPDATE 2011 Smart Manager BMS-SM1280HTLE. Note: Computer NOT supplied
PRODUCT UPDATE 2011 Smart Manager Toshiba Air Conditioning are pleased to introduce a new product into our current range of control options. New The BMS-SM1280HTLE Smart Manager The BMS-SM1280HTLE has
More informationBAS Web Server Datasheet
BAS Web Server BA Systems Petershvilevej 1 DK-3200 Helsinge http://www.basystems.dk BAS Web Server belongs to a family of programable controllers designed to suit the the needs of small to medium sized
More information