1 System x Education Servicing the ServeRAID M1000 and M5000 Series SAS/SATA II Controllers October 2009 Study guide XW5196 Release 1.10 This course is owned and published by the IBM System x/bladecenter WW Service & Support Education Team and created by Beth Walker and Henry Artner.

2 Servicing the ServeRAID M1000 and M5000 Series SAS/SATA II Controllers Preface International Business Machines Corporation, 2009 All rights reserved. IBM System x Service and Support Education IBM Systems, Department EYGA. Building 203, Post Office Box 12195, Research Triangle Park, North Carolina IBM reserves the right to change specifications or other product information without notice. This publication could include technical inaccuracies or typographical errors. References herein to IBM products and services do not imply that IBM intends to make them available in other countries. IBM provides this publication as is, without warranty of any kind either expressed or implied including the implied warranties of merchantability or fitness for a particular purpose. Some jurisdictions do not allow disclaimer of expressed or implied warranties. Therefore, this disclaimer may not apply to you. Data on competitive products is obtained from publicly obtained information and is subject to change without notice. Please contact the manufacturer for the most recent information. The following terms are trademarks or registered trademarks of IBM Corporation in the United States, other countries or both: Active Memory, Active PCI, AT, BladeCenter, the e-business logo, EasyServ, Enterprise X- Architecture, EtherJet, HelpCenter, HelpWare, IBM RXE-100 Remote Expansion Enclosure, IBM XA-32, IBM XA-64, IntelliStation, LANClient Control Manager, Memory ProteXion, NetBAY3, Netfinity, Netfinity Manager, Predictive Failure Analysis, RXE Expansion Port, SecureWay, ServeRAID, ServerProven, ServicePac, SMART Reaction, SMP Expansion Module, SMP Expansion Port, UM Services, Universal Manageability, Update Connector, Wake on LAN, XceL4 Server Accelerator Cache, XpandOnDemand scalability. IBM Corporation Subsidiaries: Lotus, Lotus Notes, Domino, and SmartSuite are trademarks of Lotus Development Corporation. Tivoli and Planet Tivoli are trademarks of Tivoli Systems, Inc. LLC, Adobe, and PostScript are trademarks of Adobe Systems, Inc. Intel Celeron, LANDesk, MMX, Pentium II, Pentium III, Pentium 4, SpeedStep, and Xeon are trademarks or registered trademarks of Intel Corporation. Linux is a trademark of Linus Torvalds. Microsoft Windows and Windows NT are trademarks or registered trademarks of Microsoft Corporation. Other company, product, and service names may be trademarks or service marks of others. For more information, visit: October XW5196r110.pdf

3 Servicing the ServeRAID M1000 and M5000 Series SAS/SATA II Controllers Preface Preface Servicing the ServeRAID M5015 SAS/SATA II Controller This document may not be copied or sold, either in part or in whole, to non-ibm personnel. Please write your name and address below to personalize your copy. Issued to Address Current release date: October 2009 Current release level: 1.10 The information contained within this publication is current as of the date of the latest revision and is subject to change at any time without notice. Please forward all comments and suggestions regarding the course material format and content to your local IBM System x Service and Support Education country coordinator or contact. October XW5196r110.pdf

4 Servicing the ServeRAID M1000 and M5000 Series SAS/SATA II Controllers Preface Table of Contents Preface... 3 Table of Contents... 4 Prerequisites... 5 Objectives... 5 Servicing the ServeRAID M1000 and M5000 Series SAS/SATA II Controllers... 6 Overview... 6 M Series Naming Convention... 7 Warranty ServeRAID M 1015, M5014 and M5015 Controller Features and Limitations Controller Usage Limitations Controller Connectors Configuration Scenarios Installing the M5014 and M5015 Controllers Installing the ServeRAID M5000 Series Battery Assembly on the ServeRAID M5015 Controller Storage Management Tools MegaRAID Storage Manager(MSM) WebBIOS Configuration Utility (CU) Starting the WebBIOS CU MegaRAID Command Line Tool (CLI) Troubleshooting and Problem Determination Tools Collecting Data Monitoring Controllers Selecting Data Encryption Security Options Using WebBIOS Installing Drivers Installing or Updating the MegaRAID Driver in an Existing Windows System Installing the Windows System Driver in a New Windows System Installing from a Driver Update Diskette Rebuilding a Drive Logs and Debugging Techniques OS Level Debug Helpful Links Summary October XW5196r110.pdf

5 Servicing the ServeRAID M1000 and M5000 Series SAS/SATA II Controllers Preface Prerequisites You should be Server + certified or equivalent before taking this course. You should also have completed the latest release of the self-paced learning courses: a) XW Servicing IBM System x Servers - Part I b) XW Unified Extensible Firmware Interface (UEFI) Technology Brief c) XW Servicing the IBM System x3400 M2 (M/T 7836,7837) and x3500 M2 d) XW Servicing the IBM System x3550 M2 (M/T 7946) and x3650 M2 Objectives Upon completion of this course, you will be able to: 1. Provide an overview of the IBM ServeRAID M1000 and M5000 series SAS/SATA II controllers 2. List the features of the ServeRAID M5014 and M5015 controllers 3. Describe how to install the ServeRAID M5014 and M5015 controllers and the ServeRAID M5000 Series Battery Assembly 4. List the three storage management tools for the ServeRAID M series controllers 5. Perform problem determination and log-gathering activities for the ServeRAID M Series 6. Install and update drivers for the ServeRAID M Series controllers October XW5196r110.pdf

6 Servicing the ServeRAID M1000 and M5000 Series SAS/SATA II Controllers Overview Servicing the ServeRAID M1000 and M5000 Series SAS/SATA II Controllers Overview The ServeRAID M5014 and M5015 Serial Attached SCSI (SAS)/Serial ATA II (SATA II) controllers are high-performance intelligent PCI Express-to-SAS/SATA II adapters with RAID control capabilities. The ServeRAID M5014 and M5015 controllers provide reliability, high performance, and fault-tolerant disk subsystem management. They are an ideal RAID solution for the storage of workgroup, departmental, and enterprise systems. The controllers offer a cost-effective way to implement RAID in a server. The ServeRAID M1015 Serial Attached SCSI (SAS)/Serial ATA II (SATA II) controller is a low profile high performance value class solution for servers. The ServeRAID M5000 Series Battery Assembly is pre-installed on the ServeRAID M5015 controller to provide battery-protected backup of cached memory. The assembly provides protection of cached data, which allows system builders to protect cached data even during the most catastrophic system failures. Each port on the ServeRAID M1000 and M5000 controller supports SAS devices and/or SATA II devices using the following: SAS Serial SCSI Protocol (SSP), which enables communication with other SAS devices, and SATA II, which enables communication with other SATA II devices Serial Management Protocol (SMP), which communicates topology management information directly with an attached SAS expander device Serial Tunneling Protocol (STP), which enables communication with a SATA II device through an attached expander Notes: The ServeRAID M5000 Series Battery Assembly is not preinstalled on the ServeRAID M5014 controller but can be installed, if desired. SATA II is the only type of SATA supported by these RAID controllers. Carefully assess any decision to mix SAS drives and SATA drives within the same virtual drives. Although you can mix drives, IBM strongly discourages the practice. This recommendation applies to both HDDs and SSDs. October XW5196r110.pdf

7 Servicing the ServeRAID M1000 and M5000 Series SAS/SATA II Controllers Overview M Series Naming Convention The M series is a new series of ServeRAID adapters with a new naming convention. Table 1 Example of Naming Convention for new ServeRAID adapters Software Classification Generation Connector Feature/Function M M = LSI 0-6 Gb/s MR Stack 1 Future use 1-Value 5 Enterprise Class 0 None 1 Internal 2 External 3 Int and Ext 0-4 Entry Level 5 Base Adapter 6-9 Feature Upgrade Figure 1 - ServeRAID M5015 Controller Top View October XW5196r110.pdf

8 Servicing the ServeRAID M1000 and M5000 Series SAS/SATA II Controllers Overview Figure 2 - ServeRAID M5014 Controller Top View Note: The layout of the M5014 and the M5015 are identical except for the ServeRAID M5000 Series Battery Assembly, which is not shipped standard with the M5014. October XW5196r110.pdf

9 Servicing the ServeRAID M1000 and M5000 Series SAS/SATA II Controllers Overview Figure 3 - ServeRAID M1015 Controller Top View The ServeRAID M1015 is a replacement adapter for the ServeRAID BR10i. October XW5196r110.pdf

10 Servicing the ServeRAID M1000 and M5000 Series SAS/SATA II Controllers Overview Figure 4 - ServeRAID M1015 Close up View October XW5196r110.pdf

11 Servicing the ServeRAID M1000 and M5000 Series SAS/SATA II Controllers Overview Table 2 - Technical Overview of ServeRAID Controller M1015 October XW5196r110.pdf

12 Servicing the ServeRAID M1000 and M5000 Series SAS/SATA II Controllers Overview Table 3 - Technical Overview of ServeRAID Controllers M5014 and M5015 October XW5196r110.pdf

13 Servicing the ServeRAID M1000 and M5000 Series SAS/SATA II Controllers Overview Supported Servers The IBM ServeRAID M1015, M5014 and the M5015 adapter cards are both supported on the following IBM System x servers: X3400M2 X3500M2 X3550M2 X3650M2 X3200M3 ServeRAID M1015 only X3250M3 ServeRAID M1015 only Supported Operating Systems The ServeRAID M1000 and ServeRAID M5000 adapter cards support the following operating systems: Microsoft Windows Server 2003, Web Edition Microsoft Windows Server 2003/2003 R2 Microsoft Windows Server 2008/2008 R2 Microsoft Windows Small Business Server 2003/2003 R2 Red Hat Enterprise Linux 4 Red Hat Enterprise Linux 5 SUSE LINUX Enterprise Server 10 SUSE LINUX Enterprise Server 11 For detailed information on support for specific OS versions, please refer to See IBM ServerProven for the latest information about the specific versions and service packs supported: Click System x servers, and then click Disk controllers to see the support matrix. Click the check mark that is associated with the System x server in question to see the details of operating system support. October XW5196r110.pdf

14 Servicing the ServeRAID M1000 and M5000 Series SAS/SATA II Controllers Overview Operating environment The ServeRAID M5015 and ServeRAID M5014 adapter cards are supported in the following environment: Temperature: At m ( ft): 10 to 35 C (50 to 95 F) At m ( ft): 10 to 32 C (50 to 90 F) Relative humidity: 20% to 80% (non-condensing) October XW5196r110.pdf

15 Servicing the ServeRAID M1000 and M5000 Series SAS/SATA II Controllers Overview ServeRAID M5000 Series Battery Assembly Specifications Battery type: LiON, Li-Poly cell Battery operating ambient temperature: C Humidity (storage and operating): 20% to 80% non-condensing Battery storage temperature: Depends on storage time, as follows: < 30 days: 0 50 C days: 0 40 C 90 days: 0 30 C Ship Group: The ServeRAID M5015 controller ships with the following: One ServeRAID M5015 adapter card with full-height bracket One replaceable low-profile (2U) bracket One attached ServeRAID M5000 battery (plus battery kit) Documentation CD The IBM Important Notices Document The ServeRAID M5014 controller ships with the following: One ServeRAID M 5014 adapter card with full-height bracket One replaceable low-profile (2U) bracket The ServeRAID M v1.10 Utility and Documentation CD The IBM Important Notices Document The ServeRAID M5000 Series Battery Kit contains the following: SR M5000 Battery Remote Battery Cable Kit Battery Flyer Quick Install Guide Important Notices Flyer October XW5196r110.pdf

16 Servicing the ServeRAID M1000 and M5000 Series SAS/SATA II Controllers Overview Warranty This product has a one-year limited warranty. When installed in a System x server, these cards assume your system s base warranty and any IBM ServicePac upgrade. Batteries are consumables and are therefore not covered under warranty. This product is a Customer Replaceable Unit ( CRU ). IBM provides replacement CRUs for the customer to install. CRU information and replacement instructions are shipped with the customer's Machine and are available from IBM at any time on the customer's request. CRUs are designated as being either Tier 1 or a Tier 2 CRU. Installation of Tier 1 CRUs is the customer's responsibility. If IBM installs a Tier 1 CRU at the customer's request, the customer is charged for the installation. The customer may install a Tier 2 CRU themselves or request IBM to install it, at no additional charge, under the type of warranty service designated for the customer's Machine. IBM specifies in the materials shipped with a replacement CRU whether a defective CRU must be returned to IBM. When return is required, 1) return instructions and a container are shipped with the replacement CRU, and 2) the customer may be charged for the replacement CRU if IBM does not receive the defective CRU within 15 days of the customer's receipt of the replacement. October XW5196r110.pdf

17 Servicing the ServeRAID M1000 and M5000 Series SAS/SATA II Controllers Overview Part Numbers *Part numbers are subject to change without notice. Please consult the IBM Support site for the latest part numbers. Table 4 - Ordering part numbers Part Name IBM ServeRAID M5015 SAS/SATA II Controller IBM ServeRAID M5014 SAS/SATA II Controller IBM ServeRAID M5000 Series Battery Kit IBM ServeRAID M1015 SAS/SATA II Controller IBM ServeRAID M1015 Upgrade Key (Raid 5) Part Number 46M M M M M0832 Note: Changes are made periodically to the IBM Web site. The actual procedure might vary slightly from what is described in this document. See IBM ServerProven for the latest information about the specific versions and service packs supported: Click System x servers, and then click Disk controllers to see the support matrix. Click the check mark that is associated with the System x server in question to see the details of operating system support. October XW5196r110.pdf

18 Servicing the ServeRAID M5015 SAS/SATA II Controllers Features and Limitations ServeRAID M 1015, M5014 and M5015 Controller Features and Limitations Two (2) x4 internal SAS / SATA ports X8 PCI Express Gen 2 host interface M5000: RAID Levels 0, 1, 5, 10, 50 (6, 60 Optional) M1000: RAID Levels 0, 1, 10, (50 Optional with Upgrade Key) Memory o M5014: 800MHz 40-bit ECC DDR2 SDRAM Memory (256 MB) o M5015: 800MHz 72-bit ECC DDR2 SDRAM Memory (512 MB) o M1015: No memory M5000: One (1) LSI SAS2108 6Gb/s RAID on Chip processor that controls eight internal SAS/SATA ports through two x4 SAS internal connectors M5000 only M1000: One (1) LSI SAS Gb/s RAID on Chip processor that controls eight internal SAS/SATA ports through two x4 SAS internal connectors Low-profile PCIe Half Length Form Factor Encryption Services o Instant Secure Erase o Local Key Management MegaRAID Management Suite o MegaRAID Storage Manager o MegaCLI (command-line interface) o WebBIOS ServeRAID M5000 Series Battery Assembly. The battery assembly, which is preinstalled, provides protection of cached data, which allows system builders to protect cached data even during the most catastrophic system failures. Standard on the M5015, optional part for the M5014 Drive migration Drive roaming Media scan No reboot necessary after expansion October XW5196r110.pdf

19 Servicing the ServeRAID M5015 SAS/SATA II Controllers Features and Limitations The M5014 and the M5015 share the same features and functions with two important differences: 1) The M5015 has double the SDRAM memory capacity. 2) The battery comes standard with the M5015 but is optional with the M5014. SAS Features Provides eight fully independent PHYs Supports 6.0 Gb/s SAS data transfers per PHY Supports SSP to enable communication with other SAS devices Supports SMP to communicate topology management information Provides a serial, point-to-point, enterprise-level storage interface Simplifies cabling between devices Provides a scalable interface that supports up to 248 devices through the use of expanders Supports wide ports consisting of 2, 3, or 4 PHYs within a single quad port Supports narrow ports consisting of a single PHY Transfers data using SCSI information units SATA II Features Supports SATA II data transfers of 3.0 Gbs/s Supports STP data transfers of 3.0 Gbs/s Provides a serial, point-to-point storage interface Simplifies cabling between devices Eliminates the master-slave construction used in parallel ATA Allows addressing of multiple SATA II targets through an expander Allows multiple initiators to address a single target (in a fail-over configuration) through an expander 6 Gbps SAS 2.0 technology has been introduced to address data off-load bottlenecks in the direct-access storage environment. This new throughput doubles the transfer rate of the previous generation. SAS 2.0 is designed for backward compatibility with 3 Gbps SAS as well as with 3 Gbps SATA hard drives. Regardless of the drive speed, 6 Gbps ServeRAID adapters will deliver significant performance improvements in both read and write applications as compared to their 3 Gbps predecessors. October XW5196r110.pdf

20 Servicing the ServeRAID M5015 SAS/SATA II Controllers Features and Limitations Solid State Drive Features The firmware supports Solid State Drives attached to ServeRAID-MR SAS controllers. The features and operations for SSDs are the same as for hard disk drives (HDDs), and these drives are expected to behave like SATA HDDs or SAS HDDs. The major advantages of SSDs include: High random read speed (because there is no read-write head to move) High performance-to-power ratio, as these drives have very low power consumption compared to HDDs Low latency High mechanical reliability Lower weight and size (for low-capacity SSD drives) The WebBIOS Configuration Utility and the MegaRAID Storage Manager utility display the SSDs by the type, either SAS or SATA. For example, a SATA SSD drive displays as SSD (SATA). HDDs are identified simply as SAS or SATA. Note: ServeRAID-MR implements support for only those SATA SSD drives which support ATA-8 ACS compliance. Virtual drives can consist of both SSD devices and HDDs. For a virtual drive that consists of SSDs only, both SAS SSD drives and SATA SSD drives are allowed in that virtual drive. For virtual drives that have both SSDs and HDDs, SAS and SATA HDD drives may be combined with SAS and SATA SSD devices in various combinations. Note: Support for SATA SDD drives applies only to those drives that support ATA-8 ACS compliance. October XW5196r110.pdf

21 Servicing the ServeRAID M5015 SAS/SATA II Controllers Features and Limitations MegaRAID Features Usability Extensions to RAID 1 Revertible Hot Spare Unified Extensible Firmware Interface (UEFI ) 2.0 Support VMware ESXi Support Data Protection & Availability Intelligent Battery Backup Unit Single Controller Multi-pathing SSD Guard Performance Load Balancing SSD Support Environmentally Friendly Dimmer Switch A Note About UEFI 2.0 Support: Unified Extensible Firmware Interface (UEFI) 2.0 was developed to do the following: Define a clean interface between operating systems and the hardware platform at boot time Support an architecture-independent mechanism for initializing add-in cards. UEFI 2.0 provides ServeRAID M1000 and M5000 customers with expanded platform support. The UEFI 2.0 driver, a boot service device driver, handles block IO requests and SCSI pass-through commands (SPT), and offers the ability to launch pre-boot ServeRAID-MR management applications through a driver configuration protocol (DCP). The UEFI driver also supports driver diagnostic protocol, which allows administrators to access pre-boot diagnostics. October XW5196r110.pdf

22 Servicing the ServeRAID M5015 SAS/SATA II Controllers Features and Limitations Controller Usage Limitations The ServeRAID M5015 controller has the following limitations: You can connect only one device per SAS PHY unless you use an expander. You can use a maximum cable length of six feet (using shorter cables is preferred). Cables have to meet the SAS specification. The controllers support mixing of drive types on the same backplane but not in the same array. Storage Manager will span available hard disks regardless of technology, as long as the technologies and the device drivers support the formatting expected on the virtual drive. Refer to the User s Guide for the ServeRAID M5015 SAS/SATA II Controller for information about the power requirements and the minimum and the maximum temperature ranges. October XW5196r110.pdf

23 Servicing the IBM ServeRAID M5015 SAS/SATA II Controllers Controller Connectors Controller Connectors Figure 1- M5014 and M5015 Controller Jumper and Connector Layout Diagram Note: JT2 and JT4 are behind the battery assembly when it is installed, but they are still accessible. Refer to Table 1 on the next page for an explanation of Figure 1 above. Refer to Figure 1 and its corresponding explanation when installing the controller in a system. October XW5196r110.pdf

24 Servicing the IBM ServeRAID M5015 SAS/SATA II Controllers Controller Connectors Table 1 Explanation of Controller Connectors Jumper/Connector Type JT2 (2-pin connector) JT3 (20-pin connector) JT4 (2-pin connector) JT6 JT7 SAS Activity LED header Battery Backup connector Global Drive Fault LED header x4 SAS Ports 3 0 Mini SAS 4i connector x4 SAS Ports 7 4 Mini SAS 4i connector Description Connects to an LED that indicates drive activity. Connects the Battery assembly Unit directly to the ServeRAID M5015 controller. Connects to an LED that indicates whether a drive is in a fault condition. Connects the cables from the controller to SAS drives or SATA II drives, or a SAS expander. Connects the cables from the controller to SAS drives or SATA II drives, or a SAS expander. JT8 Modular RAID Key header Reserved for IBM use JT9 (2-pin connector) Set Factory Defaults connector Returns the board settings to the defaults set in the factory. JT10 Test header Reserved for IBM use JT11(3-pin shielded header) JT12 JT13 IPMI-style SMBus (System Management)/I2C header Individual Drive Fault LED header for Eight PHYs (0-7) Receiver/ Transmitter debugging Provides enclosure management support. Indicates drive faults. There is one LED per port. When lit, each LED indicates the corresponding drive has failed or is in the Unconfigured-Bad state. The LEDs function in a direct attach configuration (there are no SAS expanders). Direct attach is defined as a maximum of one drive connected directly to each port. This header is used for controllers with internal SAS ports. Reserved for IBM use October XW5196r110.pdf

25 Servicing the IBM ServeRAID M5015 SAS/SATA II Controllers Configuration Scenarios Configuration Scenarios There are three main configuration scenarios for the SAS RAID controllers: 1. Low-end, internal SATA II configurations: In this configuration, use the RAID controller as a high-end SATA II compatible controller that connects up to eight disks either directly or through a port expander. This configuration is mostly for low-end or entry servers. Enclosure management is provided through out-of-band I2C bus. Side bands of both types of internal SAS connectors support the SFF-8485 (SGPIO) interface. 2. Midrange internal SAS configurations: This configuration is similar to the internal SATA II configurations, but with high-end disks. This configuration is more suitable for low-range to midrange servers. 3. High-end external SAS/SATA II configurations: This configuration is for both internal connectivity and external connectivity, using SATA II drives, SAS drives, or both. External enclosure management is supported through inband, SCSI-enclosed storage. The configuration must support STP and SMP. Figure 2 shows a direct-connect configuration. The Inter-IC (I2C) interface communicates with peripherals. The external memory bus provides a 32-bit memory bus, parity checking, and chip select signals for pipelined synchronous burst static random access memory (PSBRAM), nonvolatile static random access memory (NVSRAM), and Flash ROM. Figure 2 - SAS Direct-Connect Application Diagram October XW5196r110.pdf

26 Servicing the IBM ServeRAID M5015 SAS/SATA II Controllers Configuration Scenarios Figure 3 shows an example of a SAS RAID controller configured with an LSISASx12 expander that is connected to SAS disks, SATA II disks, or both. Figure 3 - Example of a SAS RAID Controller Configured with an LSISASx12 Expander October XW5196r110.pdf

27 Servicing the IBM ServeRAID M5015 SAS/SATA II Controllers Installing the M5014 and M5015 Controllers Installing the M5014 and M5015 Controllers Important Notes: 1) The installation instructions are the same for the M5014 and M5015 types. 2) Read the corresponding Quick Install Guide for the controller before you begin installing any controller. Note: Record your controller serial number in a safe location for future reference. The ServeRAID M5000 Series Battery Assembly ships with the controller. Mount the battery assembly directly to the controller using a daughtercard. For more information about the M5015 controller and the battery assembly, refer to the ServeRAID M5015 SAS/SATA Controller User s Guide on the ServeRAID-M Support CD. Installation Requirements: A ServeRAID M5015 SAS/SATA II controller A host system with an available PCI Express expansion slot The ServeRAID-MR Support CD, containing the drivers and the documentation The necessary internal cables SAS physical disks or SATA II physical disks (Mechanical or Solid State Devices, SSDs) To install the controller, perform the following steps: 1) Ensure that all installation requirements listed above are met. 2) Remove the controller from the antistatic bag, making sure you follow precautions to avoid static buildup or damage. 3) Review the controller connector locations as described in the Quick Install Guide that corresponds with the controller type you are installing. 4) Prepare your computer by unplugging the power cords from the power supplies, disconnecting the computer from the network, and removing the computer cover. Be sure the computer is disconnected from all networks at this time. October XW5196r110.pdf

28 Servicing the IBM ServeRAID M5015 SAS/SATA II Controllers Installing the M5014 and M5015 Controllers 5) Install the controller on the motherboard by inserting the controller in a PCI Express slot on the motherboard, as shown in Figure 1. Press down gently but firmly to seat the card correctly in the slot. 6) Secure the controller to the computer chassis with the bracket screw as shown in Figure 1. Figure 1 Installing the Controller in a Motherboard Note: This is a PCI Express x8 card and it can operate in x8 or x16 slots. Some PCI- E slots support only PCI-E graphics cards; if a RAID controller is installed, it will not function. October XW5196r110.pdf

29 Servicing the IBM ServeRAID M5015 SAS/SATA II Controllers Installing the M5014 and M5015 Controllers 7. After the controller is installed on the motherboard, configure and install the SAS Devices, SATA II Devices or both. 8. Connect the cables between the controller and the SAS devices, SATA II devices, or both. Refer to the external device documentation to view connector locations for the external devices. 9. Install the computer cover and reconnect the power cords. Turn on the power to the computer, making sure that the power is turned on to the SAS devices and the SATA II devices before or at the same time as the host computer. If the power is turned on to the computer before it is turned on to the devices, the computer might not recognize the devices. 10. During boot, a BIOS message similar to the following displays: Caution: The battery must charge for at least six hours under normal operating conditions. To protect your data, the firmware changes the Write Policy to writethrough until the battery unit is sufficiently charged. When the battery unit is charged, the controller firmware changes the Write Policy to write-back to take advantage of the performance benefits of data caching. 11. Run the WebBIOS Configuration Utility to configure the physical arrays and the logical drives. When the message Press <Ctrl><H> for WebBIOS displays on the screen, press CTRL+H immediately to run the utility. 12. Install the Operating System driver. The ServeRAID-M Support CD includes drivers for the supported operating systems. View the supported operating systems and download the latest drivers for the controller at For updates, click Downloads and drivers. Access the download center and follow the steps to download the driver. 13. Refer to the ServeRAID-M Device Driver Installation Guide on the CD for details on installing the driver. Be sure to use the latest Service Packs provided by the operating system manufacturer and review the readme file that accompanies the driver. October XW5196r110.pdf

30 Servicing the IBM ServeRAID M5015 SAS/SATA II Controllers Installing the M5014 and M5015 Controllers Installing the ServeRAID M5000 Series Battery Assembly on the ServeRAID M5015 Controller The battery assembly mounts directly to the ServeRAID M5015 controller using a small board-to-board connector (daughtercard). Figure 2 displays the bottom view and the top view of the card. (The top side is the side that is visible after the battery assembly is installed on the RAID controller.) Note that this unit combines a battery pack with a daughtercard. Figure 2 Views of the ServeRAID M5000 Series Battery Assembly 1 - J4 battery pack harness connector 2 - J5 board-to-board connector 3 - J2 connector 4 - Battery pack harness October XW5196r110.pdf

31 Servicing the IBM ServeRAID M5015 SAS/SATA II Controllers Installing the M5014 and M5015 Controllers Perform the following steps to mount the battery assembly directly to the ServeRAID M5015 controller using the daughtercard. (All components are installed on the bottom of the card. The battery is installed on the top. The maximum height of components installed on the battery assembly is ) 1. Ground yourself, and remove the battery assembly daughtercard from the package. 2. Insert the battery pack harness into the 5-pin J4 connector on the bottom of the battery assembly. 3. Hold the battery assembly daughtercard so that the battery side is up and the J5 connector lines up with the JT3 battery assembly connector on the controller, as shown in Figure 3. Figure 3 Lining up the Connectors 4. Carefully press the battery assembly onto the controller, so that the two connectors are firmly joined. 5. Secure the battery assembly to the controller with the screws and the standoffs in the three screw holes. The standoffs are threaded at both ends and a screw goes into each end. 6. Use the Phillips-head screws that are provided to secure the battery assembly to the controller. October XW5196r110.pdf

32 Servicing the IBM ServeRAID M5015 SAS/SATA II Controllers Installing the M5014 and M5015 Controllers 7. Install the controller in the computer in the PCI Express slot, as shown in Figure 1 above. 8. Press down gently, but firmly, to make sure that the controller is properly seated in the slot. The bottom edge of the controller must be flush with the slot. Caution: Never apply pressure to the battery assembly when you insert the controller. Instead, press down only on the top edge of the controller, as shown in Figure 1 above. Connecting the ServeRAID M5015 SAS/SATA II Controller to Physical Drives This subsection provides step-by-step instructions for connecting the ServeRAID M5014 and M5015 controllers to the SAS physical drives and the SATA II physical drives. Figure 4 demonstrates how to connect the internal SAS cable from the controller to the drives. Follow the steps below to connect the ServeRAID M5015 controller with internal connectors to a physical drive: 1. Plug the connector on the internal cable into the internal connector on the controller. 2. Plug the connector on the other end of the internal cable into the connector on the SAS physical drive or the SATA II physical drive. 3. If you have another physical drive, connect it to another plug on the internal cable. 4. You can connect other devices if the cable has more connectors. October XW5196r110.pdf

33 Servicing the IBM ServeRAID M5015 SAS/SATA II Controllers Installing the M5014 and M5015 Controllers Figure 4 Connecting the internal SAS cable to the drives October XW5196r110.pdf

34 Servicing the IBM ServeRAID M5015 SAS/SATA II Controllers Storage Management Tools Storage Management Tools The user has the choice of three tools to manage storage tasks and monitor activities for the M5014 and M5015 controllers: 1) MegaRAID Storage Manager - MSM A Powerful management GUI used to complete many advanced storage management operations such as RAID Level Migration, adding HotSpares, etc. 2) WebBIOS Configuration Utility (CU) A CU used to create and manage RAID configurations on ServeRAID-MR controllers. Unlike the MegaRAID Storage Manager software, the WebBIOS CU resides in the SAS controller BIOS and operates independently of the operating system. 3) Command Line Tool - CLI A CLI Application for SAS, used to configure, monitor, and maintain Sanford SAS RAID storage adapters and the devices connected to them. This section describes each of the storage management tools in more detail. October XW5196r110.pdf

35 Servicing the IBM ServeRAID M5015 SAS/SATA II Controllers Storage Management Tools MegaRAID Storage Manager(MSM) Features MegaRAID Storage Manager (MSM) is a GUI-based application that allows simplified management of numerous storage configuration and virtual disk tasks, including: Creating a New Storage Configuration Adding Hotspare Disks Changing Adjustable Task Rates Changing Virtual Disk Properties Changing a Virtual Disk Configuration Deleting a Virtual Disk Saving a Storage Configuration to Disk Clearing a Storage Configuration from a Controller Adding a Saved Storage Configuration Hardware and Operating System Requirements MSM software has the following hardware requirements: PC-compatible computer with an IA-32 (32-bit) Intel Architecture processor or an EM64T (64-bit) processor and at least 128 Mbytes of system memory (256 Mbytes recommended) Drive with at least 50 Mbytes available free space MSM software is supported on the following operating systems: Microsoft Windows 2000, Microsoft Windows Server 2003, and Microsoft Windows Server 2008 Red Hat Enterprise Linux version 4.0 and version 5.0 SUSE SLES version 9 and version 10, with latest updates and service packs Novell NetWare 6.5 SCO OpenServer SCO UnixWare VMWare ESX 3.0 and ESX 3.5 October XW5196r110.pdf

36 Servicing the IBM ServeRAID M5015 SAS/SATA II Controllers Storage Management Tools WebBIOS Configuration Utility (CU) Features The WebBIOS CU is a web-based utility for configuring and managing RAID volumes. It operates independently of the operating system because the utility resides in the MegaRAID BIOS. It allows the user to perform the following tasks: Create physical arrays and logical drives for storage configurations Delete virtual disks Migrate a storage configuration to a different RAID level Detect configuration mismatches Import a foreign configuration Display adapter, virtual disk, physical drive, and battery backup unit (BBU) properties Scan devices connected to the controller Initialize virtual disks Check configurations for data consistency Provides a configuration wizard to guide users through the configuration of logical drives and physical arrays Starting the WebBIOS CU Follow these steps to start the WebBIOS CU and access the main screen. 1. When the host computer is booting, hold down the <Ctrl> key and press the <H> key when the following text appears on the screen: Copyright LSI Corporation Press <Ctrl><H> for WebBIOS The Controller Selection screen appears. 2. If the system has multiple SAS controllers, select a controller. 3. Click Start to continue. The main WebBIOS CU screen appears as shown in Figure 1 on the next page. October XW5196r110.pdf

37 Servicing the IBM ServeRAID M5015 SAS/SATA II Controllers Storage Management Tools Figure 1 the WebBIOS CU Main Screen In the right frame, the screen shows the virtual drives configured on the controller, and the drives that are connected to the controller. In addition, the screen indentifies drives that are foreign or missing. Note: In the list of virtual drives, the drive nodes are sorted based on the order in which you added the drives to the drive group, rather than the physical slot order that displays in the physical trees. To toggle between the physical view and logical view of the storage devices connected to the controller, click Physical View or Logical View in the menu on the left side of the screen. October XW5196r110.pdf

38 Servicing the IBM ServeRAID M5015 SAS/SATA II Controllers Storage Management Tools MegaRAID Command Line Tool (CLI) Features The MegaRAID CLI is a simple but useful tool for SAS-RAID related activities. Use the CLI to:. Configure MegaRAID SAS RAID storage adapters and attached devices Display information about logical drives and physical drives for the adapter and other storage components Display ongoing progress for operations on physical drives for the adapter and other storage components Change the firmware on the adapters Monitor the RAID storage systems Create and use scripts with the scriptable CLI tool Configure physical disk drives into groups and virtual disks on the controller Display configuration information for the controller, physical disk drives, and virtual disks Change virtual disk properties on the controller Change physical disk drive properties on the controller Display controller properties Load configuration to the controller from a file Save the controller configuration to a file Scan, preview, and import foreign configurations Set predefined environment variables, such as the number of controllers and virtual disks Display firmware event logs Display help for how to use the command line options Display battery unit properties Display enclosure properties October XW5196r110.pdf

39 Servicing the IBM ServeRAID M5015 SAS/SATA II Controllers Troubleshooting and Problem Determination Troubleshooting and Problem Determination Tools Collecting Data Data collection is the primary step in determining the correct service action to perform in order to resolve a client s issue. Whether the data collected is verbal from the client ( the front panel LED is blinking ) or a diagnostic data file from a specialized application, all information collected is useful toward identifying one of the four available Service actions that you can perform. The four actions are: Update (firmware, microcode, device drivers, and software) Reconfigure (parameter values, cabling, component reseats, system reboots) Replace (hardware) Escalate to the next service level Event Monitoring Using MegaRAID Storage Manager Use the MegaRAID Storage Manager (MSM) software to monitor the status of drives, virtual drives, and other storage devices. MegaRAID Storage Manager software displays the status of controllers, virtual drives, and drives on the workstation or server that you are monitoring. System errors and events are recorded in an event log file and are displayed on the screen. Special device icons appear on the screen to notify you of drive failures and other events that require immediate attention. Note: You must have administrative privileges in order to use MegaRAID Storage Manager software in either full-access or view-only mode. October XW5196r110.pdf

40 Servicing the IBM ServeRAID M5015 SAS/SATA II Controllers Troubleshooting and Problem Determination The window is composed of three main parts as shown in Figure 1 below: 1. Drive list with physical or logical views 2. Controller Information Window 3. Event Log Messages You can use MegaRAID Storage Manager to monitor events. There are settings for the delivery of alerts, the severity level of events, exceptions, and settings. MSM must be set up in Server mode in order to configure alerts and settings. Figure 1 MegaRAID Storage Manager Window Overview October XW5196r110.pdf

41 Servicing the IBM ServeRAID M5015 SAS/SATA II Controllers Troubleshooting and Problem Determination Event log messages display in the lower section of the main MSM window as shown in Figure 2. Each message that appears in the event log has a severity level that indicates the importance of the event, as shown in Table 1, a date and timestamp, and a brief description. You can click on an event to display the same information in a window. (For a list of all events, refer to the User s Guide ServeRAID-MR Software, Appendix A, Events and Messages. ) Figure 2 Event Log Messages Section Table 1 - Event Severity Levels Security Level Meaning Information Informational message. No user action is necessary. Critical Warning Fatal A component has failed, but the system has not lost data. Some component might be close to a failure point. A component has failed, and data loss has occurred or will occur. The Log menu option (as shown in Figure 3) has four options: 1. Save Log: Saves the current log to a.log file. 2. Save Log Text: Saves the current log in.txt format. 3. View Saved Log: Clears the current log information and provides the option to save the log first. 4. Clear Log: Loads a local.log file. Figure 3 Log Menu Option October XW5196r110.pdf

42 Servicing the IBM ServeRAID M5015 SAS/SATA II Controllers Troubleshooting and Problem Determination Monitoring Controllers The left panel of the MegaRAID Storage Manager window displays either the Physical view or the Logical view of the system and the devices in it, depending on which tab is selected. The Physical view shows the hierarchy of physical devices in the system. At the top of the hierarchy is the system itself. One or more controllers are installed in the system. The controller label identifies the MegaRAID controller, such as the MegaRAID SAS 8708ELP controller, so that you can easily differentiate between multiple controllers. Each controller has one or more ports. Drives and other devices are attached to the ports. The Logical view shows the hierarchy of controllers, virtual drives, and drive groups that are defined on the system. (Drives also appear in the Logical view, so you can see which drives are used by each virtual drive.) When MegaRAID Storage Manager software is running, you can see the status of all controllers in the left panel of the MegaRAID Storage Manager window. If the controller is operating normally, the controller icon looks like this:. If the controller has failed, a small red circle appears to the right of the icon. To display complete controller information, click a controller icon in the left panel of the MegaRAID Storage Manager window, and click the Properties tab in the right panel. The Controller Information window displays as shown in Figure 1 above. October XW5196r110.pdf

43 Servicing the IBM ServeRAID M5015 SAS/SATA II Controllers Troubleshooting and Problem Determination Selecting Data Encryption Security Options Using WebBIOS The Data Encryption (DE) feature in WebBIOS provides the ability to encrypt data and controller-based key management for the data security solution. This solution provides protection to the data in the event of theft or loss of physical drives. This section describes how to enable, change, or disable the drive security settings, and how to import a foreign configuration. Enabling the Security Key Identifier, Security Key, and Pass Phrase Perform the following steps to enable the encryption settings for the security key identifier, security key, and pass phrase. 1. From the main WebBIOS screen, click Encryption Settings. The Encryption Settings screen appears, as shown in Figure 4. Figure 4 - Encryption Settings Screen 2. To enable the drive security settings, select the Enable drive security radio button, then click Accept. The Enable Drive Security Introduction screen appears. This screen lists the actions you can perform: editing the security key identifier, editing the security key, and adding or changing the pass phrase (optional). 3. Click Next. The screen used to create a security key identifier appears. The controller provides a default security key. October XW5196r110.pdf

44 Servicing the IBM ServeRAID M5015 SAS/SATA II Controllers Troubleshooting and Problem Determination 4. Accept the default security key ID or enter a new security key ID. 5. Click Next. 6. The Enable Drive Security Enter Security Key screen appears. Enter a new drive security key or click Suggest to fill the new security key. Enter the new drive security key again to confirm. The security key is case-sensitive. It must be between eight and thirty-two characters and contain at least one number, one lowercase letter, one uppercase letter, and one non-alphanumeric character (e.g. < +). The space character is not permitted. 7. Click Next. The Enable Drive Security Enter Pass Phrase screen appears. You have the option to provide a pass phrase for additional security. 8. If you want to use a pass phrase, click the checkbox Use a pass phrase in addition to the security key. 9. Enter a new pass phrase and then enter the new pass phrase again to confirm. The same password rules listed above apply on this screen. Non-US keyboard users must be careful not to enter DBCS characters in the pass phrase field or security key field. Firmware works only with the ASCII character set. 10. Click Accept. The Confirm Enable Drive Security screen appears. 11. Click Yes on the Confirm Enable Drive Security screen to confirm that you want to enable the drive security settings. WebBIOS enables the security key ID, security key, and pass phrase (if applicable) that you entered and returns you to the main menu. Caution: If you forget the security key, you will lose access to your data. Be sure to record your security key information. You might need to enter the security key to perform certain operations. October XW5196r110.pdf

45 Servicing the IBM ServeRAID M5015 SAS/SATA II Controllers Troubleshooting and Problem Determination Upgrading Firmware using MSM and the MegaCLI Utility To upgrade the controller firmware using MSM, follow these steps: 1) In the left panel of the MegaRAID Storage Manager window, click the icon of the controller you need to upgrade. 2) In the right panel, click the Operations tab, and select Flash Firmware. 3) Click Go. 4) Browse for the.rom update file, and click OK. MegaRAID Storage Manager software displays the version of the existing firmware and the version of the new firmware. 5) When you are prompted to indicate if you want upgrade the firmware, click Yes. The controller is updated with the new firmware code contained in the.rom file. To upgrade the controller firmware using MegaCLI, use this syntax: Megacli adpfwflash f sasfw.rom a0 October XW5196r110.pdf

46 Servicing the IBM ServeRAID M5015 SAS/SATA II Controllers Troubleshooting and Problem Determination Installing Drivers Installing or Updating the MegaRAID Driver in an Existing Windows System Perform the following steps to install or update the MegaRAID device driver in an existing Windows system: 1. Boot the Windows operating system. The Found New Hardware Wizard starts. 2. Click the Next button and insert the driver diskette in the A drive 3. Click the Search for a Suitable Driver button, and click Next. 4. Click the Next button. In some cases, a message displays saying that this driver is not digitally signed. This message informs you that a nonsigned driver is being installed. If this message displays, click Continue Anyway. 5. Select Floppy only, and then click the Next button in the Driver Files Search Results windows. 6. Click the Finish button to complete the driver installation, then repeat this process for all adapters on your system. Installing the Windows System Driver in a New Windows System Perform the following steps to install the MegaRAID device drive in new Windows system. Windows automatically adds the driver to the registry and copies the driver to the appropriate directory. 1. Start the Windows installation by booting from the Windows CD-ROM. The system BIOS must support booting from a CD-ROM. BIOS settings might require changes to allow CD-ROM booting. See you system documentation. 2. Press F6 when the following displays at the bottom of the screen: Press F6 if you need Note: The user MUST press F6 for the system to recognize the new driver. 3. Select S to specify an additional device when the screen displays: Setup could not determine the type of one or more mass storage devices The system prompts for the manufacturer supplied hardware support disk. Note: If the screen does not display this message after you press F6, then the setup program, did not recognize the F6 command, Reboot the system and return to step Insert the driver diskette containing the Windows device driver and press ENTER. October XW5196r110.pdf

ServeRAID M5015 and M5014 SAS/SATA Controllers Product Guide

ServeRAID M5015 and M5014 SAS/SATA Controllers Product Guide ServeRAID M5015 and M5014 SAS/SATA Controllers Product Guide The ServeRAID M5015 and ServeRAID M5014 SAS/SATA Controllers for System x are the next-generation 6 Gbps SAS 2.0 RAID controllers. The adapters

More information

MegaRAID SAS e RAID Controller

MegaRAID SAS e RAID Controller MegaRAID SAS 9286-8e RAID Controller Quick Installation Guide 53823-00, Rev. A 53823-00A Revision History Version and Date 53823-00, Rev. A, Initial release of the document. Description of Changes LSI

More information

MegaRAID SAS 9285CV-8e RAID Controller. Quick Installation Guide

MegaRAID SAS 9285CV-8e RAID Controller. Quick Installation Guide MegaRAID SAS 9285CV-8e RAID Controller Quick Installation Guide LSI, the LSI & Design logo, MegaRAID, CacheVault, CacheCade, and SafeStore are trademarks or registered trademarks of LSI Corporation or

More information

Intel RAID Controller RS3DC040/ RS3DC080 Quick Installation User's Guide

Intel RAID Controller RS3DC040/ RS3DC080 Quick Installation User's Guide Intel RAID Controller RS3DC040/ RS3DC080 Quick Installation User's Guide Thank you for buying an Intel RAID Controller. Your Intel RAID Controller provides reliability, high performance, and fault-tolerant

More information

ServeRAID M5000 Series Battery Kit can provide enterprise-grade reliability businesses seek without compromising performance and reliability.

ServeRAID M5000 Series Battery Kit can provide enterprise-grade reliability businesses seek without compromising performance and reliability. ServeRAID M5014 and M5015 SAS/SATA Controllers - Two x4 port internal 6 Gbps SAS/SATA solutions for high-density servers with the flexibility to use both SAS and SATA hard drives At a glance ServeRAID

More information

ServeRAID-BR10i SAS/SATA Controller and IBM 3Gb SAS HBA v2 - New family of RAID controllers for System x servers

ServeRAID-BR10i SAS/SATA Controller and IBM 3Gb SAS HBA v2 - New family of RAID controllers for System x servers , dated March 30, 2009 ServeRAID-BR10i SAS/SATA Controller and IBM 3Gb SAS HBA v2 - New family of RAID controllers for System x servers Table of contents 1 At a glance 4 Product number 1 Overview 6 Technical

More information

ServeRAID M1015 SAS/SATA Controller for System x IBM System x at-a-glance guide

ServeRAID M1015 SAS/SATA Controller for System x IBM System x at-a-glance guide ServeRAID M1015 SAS/SATA Controller for System x IBM System x at-a-glance guide The ServeRAID M1015 SAS/SATA Controller for IBM System x is an entry-level 6 Gbps SAS 2.0 PCI Express 2.0 RAID controller.

More information

ServeRAID M5025 SAS/SATA Controller for IBM System x IBM System x at-a-glance guide

ServeRAID M5025 SAS/SATA Controller for IBM System x IBM System x at-a-glance guide ServeRAID M5025 SAS/SATA Controller for IBM System x IBM System x at-a-glance guide The ServeRAID M5025 SAS/SATA Controller for IBM System x is the next-generation 6 Gbps SAS 2.0 external RAID controller.

More information

QuickSpecs. Models. Overview

QuickSpecs. Models. Overview Overview The HP Smart Array P400 is HP's first PCI-Express (PCIe) serial attached SCSI (SAS) RAID controller and provides new levels of performance and reliability for HP servers, through its support of

More information

ServeRAID M5015 and M5014 SAS/SATA Controllers for IBM System x IBM Redbooks Product Guide

ServeRAID M5015 and M5014 SAS/SATA Controllers for IBM System x IBM Redbooks Product Guide ServeRAID M5015 and M5014 SAS/SATA Controllers for IBM System x IBM Redbooks Product Guide The ServeRAID M5015 and ServeRAID M5014 SAS/SATA Controllers for IBM System x are the next-generation 6 Gbps SAS

More information

PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapters. User Guide

PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapters. User Guide PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapters User Guide March 2010 Revision History March 2010 October 2009 July 2009 Version and Date Description of Changes Updated Figure 2, LSISAS9200-8e

More information

IBM ServeRAID-BR10il SAS/SATA Controller offers a high performance SAS and SATA host bus adapter for direct attach storage

IBM ServeRAID-BR10il SAS/SATA Controller offers a high performance SAS and SATA host bus adapter for direct attach storage IBM United States Announcement 108-352, dated June 3, 2008 IBM ServeRAID-BR10il SAS/SATA Controller offers a high performance SAS and SATA host bus adapter for direct attach storage Description...2 Prices...5

More information

MegaRAID SAS i and SAS i RAID Controllers

MegaRAID SAS i and SAS i RAID Controllers MegaRAID SAS 9266-4i and SAS 9266-8i RAID Controllers Quick Installation Guide 53063-01, Rev. B 53063-01B Revision History Version and Date Description of Changes 53063-01, Rev. B, Updated the Advanced

More information

ServeRAID-BR10il SAS/SATA Controller v2 for IBM System x IBM System x at-a-glance guide

ServeRAID-BR10il SAS/SATA Controller v2 for IBM System x IBM System x at-a-glance guide ServeRAID-BR10il SAS/SATA Controller v2 for IBM System x IBM System x at-a-glance guide The ServeRAID-BR10il SAS/SATA Controller v2 is an ideal solution for servers that need high-speed data transfer in

More information

LSI SAS i PCI Express to 12Gb/s Serial Attached SCSI (SAS) Host Bus Adapter

LSI SAS i PCI Express to 12Gb/s Serial Attached SCSI (SAS) Host Bus Adapter LSI SAS 9300-8i PCI Express to 12Gb/s Serial Attached SCSI (SAS) Host Bus Adapter User Guide Version 1.2 DB15-000984-02 For a comprehensive list of changes to this document, see the Revision History. Corporate

More information

LSI SAS i4e PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapter (HBA)

LSI SAS i4e PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapter (HBA) LSI SAS 9212-4i4e PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapter (HBA) User Guide Version 1.1 DB15-000853-01 For a comprehensive list of changes to this document, see the Revision History.

More information

QuickSpecs. Models. HP Smart Array P400i Controller. Overview

QuickSpecs. Models. HP Smart Array P400i Controller. Overview Overview The HP Smart Array P400 Serial Attached SCSI (SAS) controller (SA-P400) provides new levels of performance and reliability for HP servers, through its support of the latest SCSI technology and

More information

Models Smart Array 6402/128 Controller B21 Smart Array 6404/256 Controller B21

Models Smart Array 6402/128 Controller B21 Smart Array 6404/256 Controller B21 Overview The Smart Array 6400 high performance Ultra320, PCI-X controller family provides maximum performance, flexibility, and reliable data protection for HP ProLiant servers, through its unique modular

More information

LSI SAS i PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapter

LSI SAS i PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapter LSI SAS 9211-4i PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapter User Guide Version 1.1 DB15-000852-01 For a comprehensive list of changes to this document, see the Revision History. Corporate

More information

QuickSpecs. Models. Overview

QuickSpecs. Models. Overview Overview The HP Smart Array P800 is HP's first 16 port serial attached SCSI (SAS) RAID controller with PCI-Express (PCIe). It is the highest performing controller in the SAS portfolio and provides new

More information

IBM System x servers. Innovation comes standard

IBM System x servers. Innovation comes standard IBM System x servers Innovation comes standard IBM System x servers Highlights Build a cost-effective, flexible IT environment with IBM X-Architecture technology. Achieve maximum performance per watt with

More information

ServeRAID F GB and 800GB SAS/SATA Controllers for IBM System x Product Guide

ServeRAID F GB and 800GB SAS/SATA Controllers for IBM System x Product Guide ServeRAID F5115-200GB and 800GB SAS/SATA Controllers for IBM System x Product Guide The ServeRAID F Series family of products offers MegaRAID data protection and flexible onboard flash technology that

More information

IBM Europe, Middle East, and Africa Hardware Announcement ZG , dated November 3, 2009

IBM Europe, Middle East, and Africa Hardware Announcement ZG , dated November 3, 2009 Hardware Announcement ZG09-0870, dated November 3, 2009 ServeRAID M1015 SAS/SATA Controller and ServeRAID M1000 and M5000 feature keys offer enterprise-grade RAID solution for servers with the flexibility

More information

LSI SAS e PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapter

LSI SAS e PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapter LSI SAS 9201-16e PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapter User Guide Version 1.1 DB15-000854-01 For a comprehensive list of changes to this document, see the Revision History. Corporate

More information

LSI SAS i PCI Express to 12Gb/s Serial Attached SCSI (SAS) Host Bus Adapter

LSI SAS i PCI Express to 12Gb/s Serial Attached SCSI (SAS) Host Bus Adapter LSI SAS 9300-16i PCI Express to 12Gb/s Serial Attached SCSI (SAS) Host Bus Adapter User Guide Version 1.1 DB15-001137-01 For a comprehensive list of changes to this document, see the Revision History.

More information

QuickSpecs. What's New. Models. Overview

QuickSpecs. What's New. Models. Overview Overview The HP Smart Array P400 is HP's first PCI-Express (PCIe) serial attached SCSI (SAS) RAID controller and provides new levels of performance and reliability for HP servers, through its support of

More information

IBM System x3850 M2 servers feature hypervisor capability

IBM System x3850 M2 servers feature hypervisor capability IBM Europe Announcement ZG08-0161, dated March 25, 2008 IBM System x3850 M2 servers feature hypervisor capability Key prerequisites...2 Description...3 Product positioning... 7 Reference information...

More information

IBM System x servers. Innovation comes standard

IBM System x servers. Innovation comes standard IBM System x servers Innovation comes standard IBM System x servers Highlights Build a cost-effective, flexible IT environment with IBM X-Architecture technology. Achieve maximum performance per watt with

More information

Dell PowerEdge 6 Gbps SAS HBA and Internal Tape Adapter. User s Guide

Dell PowerEdge 6 Gbps SAS HBA and Internal Tape Adapter. User s Guide Dell PowerEdge 6 Gbps SAS HBA and Internal Tape Adapter User s Guide Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION:

More information

RAID Controller Considerations

RAID Controller Considerations :: Seite 1 von 22 :: Datenblatt zum Produkt Cisco SPARE PAIR OF SAS/SATA CABLES mit DC# 786847 :: A P P E N D I X C This appendix contains the following sections: Supported RAID Controllers and Required

More information

ServeRAID M5120 SAS/SATA Controller Lenovo Press Product Guide

ServeRAID M5120 SAS/SATA Controller Lenovo Press Product Guide ServeRAID M5120 SAS/SATA Controller Lenovo Press Product Guide The ServeRAID M5120 SAS/SATA Controller for IBM System x is a part of the ServeRAID M Series family, which offers a complete server storage

More information

ServeRAID H1110 SAS/SATA Controller Product Guide

ServeRAID H1110 SAS/SATA Controller Product Guide ServeRAID H1110 SAS/SATA Controller Product Guide The ServeRAID H1110 SAS/SATA Controller for System x offers a low-cost enterprise-grade RAID solution for internal HDDs and integrates popular SAS technology

More information

LSI SAS e PCI Express to 12Gb/s Serial Attached SCSI (SAS) Host Bus Adapter

LSI SAS e PCI Express to 12Gb/s Serial Attached SCSI (SAS) Host Bus Adapter LSI SAS 9300-8e PCI Express to 12Gb/s Serial Attached SCSI (SAS) Host Bus Adapter User Guide Version 1.3 DB15-000902-03 For a comprehensive list of changes to this document, see the Revision History. Corporate

More information

N2225 and N2226 SAS/SATA HBAs for System x Lenovo Press Product Guide

N2225 and N2226 SAS/SATA HBAs for System x Lenovo Press Product Guide N2225 and N2226 SAS/SATA HBAs for System x Lenovo Press Product Guide The N2225 and N2226 SAS/SATA HBAs for System x are low-cost, high-performance host bus adapters for high-performance connectivity between

More information

Storage Controller Considerations

Storage Controller Considerations This appendix provides storage controller (RAID and HBA) information. Supported Storage Controllers and Cables, page 1 Storage Controller Card Firmware Compatibility, page 3 RAID Backup (Supercap), page

More information

Comparing the IBM eserver xseries 440 with the xseries 445 Positioning Information

Comparing the IBM eserver xseries 440 with the xseries 445 Positioning Information Comparing the IBM eserver xseries 440 with the xseries 445 Positioning Information Main Feature x440 server x445 server IBM chipset First generation XA-32 Second generation XA-32 SMP scalability Support

More information

High Density RocketRAID EJ6172 Device Board Data RAID Installation Guide

High Density RocketRAID EJ6172 Device Board Data RAID Installation Guide High Density RocketRAID 2711 + EJ6172 Device Board Data RAID Installation Guide Introduction The HighPoint High Density Storage Solutions hammer down high density storage cost over a single mini- SAS port.

More information

USER S GUIDE. ServeRAID-MR10k. November 2007 IBM P/N: 43W7850

USER S GUIDE. ServeRAID-MR10k. November 2007 IBM P/N: 43W7850 USER S GUIDE ServeRAID-MR10k November 2007 IBM P/N: 43W7850 Second Edition (November 2007) Copyright International Business Machines Corporation 2007. All rights reserved. US Government Users Restricted

More information

ServeRAID M5025 SAS/SATA Controller offers an eight-port external 6 Gbps SAS/SATA solution for high-density servers

ServeRAID M5025 SAS/SATA Controller offers an eight-port external 6 Gbps SAS/SATA solution for high-density servers IBM United States Hardware Announcement 110-172, dated August 10, 2010 offers an eight-port external 6 Gbps SAS/SATA solution for high-density servers Table of contents 1 Overview 6 Publications 3 Key

More information

2013 LENOVO. ALL RIGHTS RESERVED.

2013 LENOVO. ALL RIGHTS RESERVED. RAID Product Directions LSI is strategic partner for complete RAID solutions Industry leader in RAID technology Best in class storage subsystem performance LSI RAID technology / products supported across

More information

Target Environments The Smart Array 6i Controller offers superior investment protection to the following environments: Non-RAID

Target Environments The Smart Array 6i Controller offers superior investment protection to the following environments: Non-RAID Overview The Smart Array 6i controller is an Ultra320 intelligent array controller for entry-level, hardware-based fault tolerance for protection of OS, applications, and logs. Most models have one internal-only

More information

ServeRAID M1115 SAS/SATA Controller Product Guide

ServeRAID M1115 SAS/SATA Controller Product Guide ServeRAID M1115 SAS/SATA Controller Product Guide The ServeRAID M1115 SAS/SATA Controller is a low-cost RAID 0/1/10 solution that can be upgraded to a cacheless RAID 5 with a Features-on-Demand license

More information

Dell EMC BOSS-S1 (Boot Optimized Server Storage) User's Guide

Dell EMC BOSS-S1 (Boot Optimized Server Storage) User's Guide Dell EMC BOSS-S1 (Boot Optimized Server Storage) User's Guide Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION

More information

LSI SAS i4e PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapter

LSI SAS i4e PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapter LSI SAS 9207-4i4e PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapter User Guide Version 2.1 DB15-000858-02 Revision History Version and Date Description of Changes Final Version 2.1, Updated

More information

Lenovo ThinkSystem RAID 530 Series Internal RAID Adapters Product Guide

Lenovo ThinkSystem RAID 530 Series Internal RAID Adapters Product Guide Lenovo ThinkSystem RAID 530 Series Internal RAID Adapters Product Guide The ThinkSystem RAID 530 family are entry-level 12 Gb SAS/SATA internal RAID adapters that offer a cost-effective RAID solution for

More information

DP SATA 6Gb/s PCIe i/e Quick Installation Guide

DP SATA 6Gb/s PCIe i/e Quick Installation Guide DP SATA 6Gb/s PCIe i/e Quick Installation Guide Introducing the SATA 6Gb/s PCIe i/e The DP SATA 6Gb/s PCIe i/e adds 2 SATA 6Gb/s & a PATA connectors to PCIe-equipped computers. Features and Benefits Dual

More information

ServeRAID M5225-2GB External SAS/SATA Controller Product Guide

ServeRAID M5225-2GB External SAS/SATA Controller Product Guide ServeRAID M5225-2GB External SAS/SATA Controller Product Guide The ServeRAID M5225-2GB SAS/SATA Controller is a 12 Gb SAS RAID controller with two external connectors to connect to SAS expansion enclosures.

More information

LSI SAS e PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapter

LSI SAS e PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapter LSI SAS 9207-8e PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapter User Guide Version 2.3 DB15-000859-04 For a comprehensive list of changes to this document, see the Revision History. Corporate

More information

Chapter 2 Using WebBIOS This chapter explains the WebBIOS setup procedures. WebBIOS is a basic utility to set up and manage the array controller.

Chapter 2 Using WebBIOS This chapter explains the WebBIOS setup procedures. WebBIOS is a basic utility to set up and manage the array controller. MegaRAID SAS User s Guide Areas Covered Before Reading This Manual This section explains the notes for your safety and conventions used in this manual. Chapter 1 Overview This chapter provides an overview

More information

LSI SAS e PCI Express to 12Gb/s Serial Attached SCSI (SAS) Host Bus Adapter

LSI SAS e PCI Express to 12Gb/s Serial Attached SCSI (SAS) Host Bus Adapter LSI SAS 9300-16e PCI Express to 12Gb/s Serial Attached SCSI (SAS) Host Bus Adapter User Guide Version 2.2 DB15-000982-03 For a comprehensive list of changes to this document, see the Revision History.

More information

CHENBRO CK port SAS Expander Card User s Manual. Version B0. September / 01 / 2009

CHENBRO CK port SAS Expander Card User s Manual. Version B0. September / 01 / 2009 CHENBRO CK12803 28-port SAS Expander Card Version B0 September / 01 / 2009 1 Copyright Copyright 2008 CHENBRO Micom Co., Ltd.. All rights reserved. Unless otherwise indicated, all materials in this manual

More information

IBM 6 Gb Performance Optimized HBA IBM Redbooks Product Guide

IBM 6 Gb Performance Optimized HBA IBM Redbooks Product Guide IBM 6 Gb Performance Optimized HBA IBM Redbooks Product Guide The IBM 6 Gb Performance Optimized HBA is an ideal host bus adapter to connect to high-performance solid state drives. With a PCI Express 2.0

More information

Suggested use: infrastructure applications, collaboration/ , web, and virtualized desktops in a workgroup or distributed environments.

Suggested use: infrastructure applications, collaboration/ , web, and virtualized desktops in a workgroup or distributed environments. The IBM System x3500 M4 server provides outstanding performance for your business-critical applications. Its energy-efficient design supports more cores, memory, and data capacity in a scalable Tower or

More information

QuickSpecs. Models. HP Smart Array 642 Controller. Overview. Retired

QuickSpecs. Models. HP Smart Array 642 Controller. Overview. Retired Overview The Smart Array 642 Controller (SA-642) is a 64-bit, 133-MHz PCI-X, dual channel, SCSI array controller for entry-level hardwarebased fault tolerance. Utilizing both SCSI channels of the SA-642

More information

Serial ATA PCI RAID Quick Installation Guide

Serial ATA PCI RAID Quick Installation Guide Serial ATA PCI RAID Quick Installation Guide Introducing the Serial ATA PCI RAID The Serial ATA PCI RAID is an ultra high-speed two channel Serial ATA controller board for use in Pentium-class computers.

More information

MegaRAID CacheVault Flash Module 02

MegaRAID CacheVault Flash Module 02 MegaRAID CacheVault Flash Module 02 Quick Installation Guide 53378-00, Rev. B MegaRAID CacheVault Flash Module CVFM02 Quick Installation Guide Revision History Version and Date Description of Changes 53378-00,

More information

SAS 2.5-inch Hybrid Hard Drives for System x Product Guide

SAS 2.5-inch Hybrid Hard Drives for System x Product Guide SAS 2.5-inch Hybrid Hard Drives for System x Product Guide The IBM SAS 2.5-inch Hybrid hard disk drives (HDDs) for System x provide cost-effective performance and density by combining a cache of NAND flash

More information

IBM BladeCenter S SAS RAID Controller Module supports SAS expansion, availability and connectivity, plus a new 750GB NL SAS HD for BladeCenter S

IBM BladeCenter S SAS RAID Controller Module supports SAS expansion, availability and connectivity, plus a new 750GB NL SAS HD for BladeCenter S , dated September 09, 2008 IBM BladeCenter S SAS RAID Controller Module supports SAS expansion, availability and connectivity, plus a new 750GB NL SAS HD for BladeCenter S Table of contents 2 Key prerequisites

More information

ServeRAID M5016 SAS/SATA Controller IBM Redbooks Product Guide

ServeRAID M5016 SAS/SATA Controller IBM Redbooks Product Guide ServeRAID M5016 SAS/SATA Controller IBM Redbooks Product Guide The ServeRAID M5016 SAS/SATA Controller offers an enterprise grade RAID solution for internal HDDs and integrates popular 6 Gbps SAS technology

More information

N2225 and N2226 SAS/SATA HBAs for IBM System x IBM Redbooks Product Guide

N2225 and N2226 SAS/SATA HBAs for IBM System x IBM Redbooks Product Guide N2225 and N2226 SAS/SATA HBAs for IBM System x IBM Redbooks Product Guide The N2225 and N2226 SAS/SATA HBAs for IBM System x are low-cost, high-performance host bus adapters for high-performance connectivity

More information

Installing the IBM ServeRAID Cluster Solution

Installing the IBM ServeRAID Cluster Solution Installing the IBM ServeRAID Cluster Solution For IBM Netfinity ServeRAID-4x Ultra160 SCSI Controllers Copyright IBM Corp. 2000 1 2 IBM Netfinity Installing the IBM ServeRAID Cluster Solution Chapter 1.

More information

Installation and User's Guide

Installation and User's Guide IBM Netfinity High-Availability Cluster Solutions Using the IBM ServeRAID -3H and IBM ServeRAID-3HB Ultra2 SCSI Controllers Installation and User's Guide IBM IBM IBM Netfinity High-Availability Cluster

More information

ServeRAID M5016 SAS/SATA Controller IBM System x at-a-glance guide

ServeRAID M5016 SAS/SATA Controller IBM System x at-a-glance guide ServeRAID M5016 SAS/SATA Controller IBM System x at-a-glance guide The ServeRAID M5016 SAS/SATA Controller offers an enterprise grade RAID solution for internal s and integrates popular 6 Gbps SAS technology

More information

Lenovo ThinkSystem RAID 930 Series Internal RAID Adapters Product Guide

Lenovo ThinkSystem RAID 930 Series Internal RAID Adapters Product Guide Lenovo ThinkSystem RAID 930 Series Internal RAID Adapters Product Guide The ThinkSystem RAID 930 family of internal 12 Gbps SAS RAID controllers are high-performance RAIDon-chip (ROC) adapters. These adapters

More information

ServeRAID M1215 SAS/SATA Controller Product Guide

ServeRAID M1215 SAS/SATA Controller Product Guide ServeRAID M1215 SAS/SATA Controller Product Guide The ServeRAID M1215 SAS/SATA Controller is a low-cost 12 Gbps internal RAID 0/1/10 solution that can be upgraded to a cacheless RAID 5 with a Features

More information

Dell EMC PowerEdge RAID Controller (PERC) 10 User s Guide

Dell EMC PowerEdge RAID Controller (PERC) 10 User s Guide Dell EMC PowerEdge RAID Controller (PERC) 10 User s Guide Regulatory Model: UCPA-901, UCPB-900, UCSA-901, UCSB-900, UCSE-900, UCPE-900, UCPA-1001, UCPB-1000, UCPE-1000, UCSN-1000, UCPN-1000, UCPJ-1000,

More information

Serial ATA PCI RAID Quick Installation Guide

Serial ATA PCI RAID Quick Installation Guide Serial ATA PCI RAID Quick Installation Guide Introducing the Serial ATA PCI RAID The Serial ATA PCI RAID is an ultra high-speed two channel Serial ATA controller board for use in Pentium-class computers.

More information

MegaRAID Remote Kit for the LSIiBBU06, LSIiBBU07, and LSIiBBU08 Intelligent Battery Backup Units. Quick Installation Guide

MegaRAID Remote Kit for the LSIiBBU06, LSIiBBU07, and LSIiBBU08 Intelligent Battery Backup Units. Quick Installation Guide MegaRAID Remote Kit for the LSIiBBU06, LSIiBBU07, and LSIiBBU08 Intelligent Battery Backup Units Quick Installation Guide Version A July 2010 Revision History Version and Date Version A, July 2010 Initial

More information

High Density RocketRAID Rocket EJ240 Device Board Data RAID Installation Guide

High Density RocketRAID Rocket EJ240 Device Board Data RAID Installation Guide High Density RocketRAID 2711 + Rocket EJ240 Device Board Data RAID Installation Guide Introduction The HighPoint High Density Storage Solutions hammer down high density storage cost over a single mini-

More information

Storage Controller Considerations

Storage Controller Considerations This appendix provides storage controller (RAID) information. Supported Storage Controllers and Cables, page 1 Storage Controller Card Firmware Compatibility, page 2 RAID Backup (Supercap), page 2 Write-Cache

More information

MegaRAID CacheVault Power Module 02

MegaRAID CacheVault Power Module 02 MegaRAID CacheVault Power Module 02 Quick Installation Guide 53377-00, Rev. B Revision History Version and Date Description of Changes 53377-00, Rev. B, Revised the copyright information and Figure 3.

More information

IBM System x3850 M2 servers feature dual-core and quad-core Intel Xeon MP processors

IBM System x3850 M2 servers feature dual-core and quad-core Intel Xeon MP processors IBM Europe Announcement ZG07-0649, dated October 16, 2007 IBM System x3850 M2 servers feature dual-core and quad-core Intel Xeon MP processors Key prerequisites...3 Description...3 Product positioning...

More information

ServeRAID C100 and C105 Product Guide

ServeRAID C100 and C105 Product Guide ServeRAID C100 and C105 Product Guide The ServeRAID C100 and ServeRAID C105 are integrated SATA controllers with software RAID capabilities. They are a cost-effective way to provide reliability, performance,

More information

IBM System Storage DS3000 series Interoperability Matrix IBM System Storage DS3000 series Interoperability Matrix

IBM System Storage DS3000 series Interoperability Matrix IBM System Storage DS3000 series Interoperability Matrix IBM System Storage DS3000 series Interoperability Matrix - 1 - IBM System Storage DS3000 series Interoperability Matrix Last Revised: 8/28/2007 IBM System Storage DS3000 series Interoperability Matrix

More information

ServeRAID M5000 Series Performance Accelerator Key for System x Product Guide

ServeRAID M5000 Series Performance Accelerator Key for System x Product Guide ServeRAID M5000 Series Performance Accelerator Key for System x Product Guide The ServeRAID M5000 Series Performance Accelerator Key for System x enables performance enhancements needed by emerging SSD

More information

NEC Express5800/R120e-1M System Configuration Guide

NEC Express5800/R120e-1M System Configuration Guide NEC Express5800/R120e-1M System Configuration Guide Introduction This document contains product and configuration information that will enable you to configure your system. The guide will ensure fast and

More information

Retired. Models Smart Array 6402/128 Controller B21 Smart Array 6404/256 Controller B21

Retired. Models Smart Array 6402/128 Controller B21 Smart Array 6404/256 Controller B21 Overview The Smart Array 6400 high performance Ultra320, PCI-X controller family provides maximum performance, flexibility, and reliable data protection for HP ProLiant servers, through its unique modular

More information

esata II PCIe i/e Quick Installation Guide

esata II PCIe i/e Quick Installation Guide esata II PCIe i/e Quick Installation Guide Introducing the esata II PCIe i/e The esata II PCIe i/e is an ultra high-speed dual channel Serial ATA Generation 2 controller for use in PCI Express enabled

More information

IBM System Storage DS3000 series Interoperability Matrix IBM System Storage DS3000 series Interoperability Matrix

IBM System Storage DS3000 series Interoperability Matrix IBM System Storage DS3000 series Interoperability Matrix IBM System Storage DS3000 series Interoperability Matrix - 1 - IBM System Storage DS3000 series Interoperability Matrix Last Revised: 9/19/2007 IBM System Storage DS3000 series Interoperability Matrix

More information

IBM High IOPS MLC Adapters Product Guide

IBM High IOPS MLC Adapters Product Guide IBM High IOPS MLC Adapters Product Guide The IBM 365GB, 785GB and 1.2TB MLC Mono and 2.4TB MLC Duo High IOPS Adapters for IBM System x, IBM BladeCenter, and IBM Flex System are second-generation adapters

More information

SAS Connectivity Card (CIOv) for IBM BladeCenter IBM Redbooks Product Guide

SAS Connectivity Card (CIOv) for IBM BladeCenter IBM Redbooks Product Guide SAS Connectivity Card (CIOv) for IBM BladeCenter IBM Redbooks Product Guide The SAS Connectivity Card (CIOv) for IBM BladeCenter is an expansion card that offers the ideal way to connect the supported

More information

Dell PowerEdge FD332. Owner's Manual. Regulatory Model: E02B Regulatory Type: E02B003

Dell PowerEdge FD332. Owner's Manual. Regulatory Model: E02B Regulatory Type: E02B003 Dell PowerEdge FD332 Owner's Manual Regulatory Model: E02B Regulatory Type: E02B003 Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your computer.

More information

RAID Card with HyperDuo

RAID Card with HyperDuo 4 Channel, 2 msata + 2 SATA 6Gb/s RAID Card with HyperDuo User Manual Model: UGT-MST644R All brand names and trademarks are properties of their respective owners. www.vantecusa.com Contents: Chapter 1:

More information

ServeRAID M5210 and M5210e SAS/SATA Controllers Product Guide

ServeRAID M5210 and M5210e SAS/SATA Controllers Product Guide ServeRAID M5210 and M5210e SAS/SATA Controllers Product Guide The ServeRAID M5210 and M5210e SAS/SATA Controllers are high performance 12 Gb SAS controllers for internal disk storage. They are part of

More information

ServeRAID-MR10i SAS/SATA Controller IBM System x at-a-glance guide

ServeRAID-MR10i SAS/SATA Controller IBM System x at-a-glance guide ServeRAID-MR10i SAS/SATA Controller IBM System x at-a-glance guide The ServeRAID-MR10i SAS/SATA Controller is a low-cost PCI Express RAID controller for Internal System RAID 0, 1, 10, 5, 50, 6, and 60.

More information

FASTTRAK TX4000 QUICK START GUIDE. Version 1.2

FASTTRAK TX4000 QUICK START GUIDE. Version 1.2 FASTTRAK TX4000 QUICK START GUIDE Version 1.2 FastTrak TX4000 Copyright 2002 Promise Technology, Inc. Copyright by Promise Technology, Inc. (Promise Technology). No part of this manual may be reproduced

More information

Intel RAID Controller RS2BL080 and RS2MB044

Intel RAID Controller RS2BL080 and RS2MB044 Intel RAID Controller RS2BL080 and RS2MB044 Technical Product Specification October 2010 Enterprise Platforms and Services Division Revision History Intel RAID Controller RS2BL080 and RS2MB044 Technical

More information

DP SATA 6Gb/s 2S1P PCIe Installation Guide

DP SATA 6Gb/s 2S1P PCIe Installation Guide Introduction DP SATA 6Gb/s 2S1P PCIe Installation Guide The DP SATA 6Gb/s 2S1P PCIe will add 2 SATA 6Gb/s & a PATA connectors to PCIe-equipped computers. Features and Benefits Adds two SATA 6Gb/s and one

More information

ServeRAID M5110 and M5110e SAS/SATA Controllers Product Guide

ServeRAID M5110 and M5110e SAS/SATA Controllers Product Guide ServeRAID M5110 and M5110e SAS/SATA Controllers Product Guide The ServeRAID M5110 and M5110e SAS/SATA controllers are 6 Gb SAS/SATA internal RAID controllers. This adapter and embeded controller are part

More information

RocketRAID 3600 Series

RocketRAID 3600 Series RocketRAID 3600 Series SATA 6Gb/s PCI-Express 2.0 x 8 RAID HBA User s Guide Revision: 1.01 Jun. 23, 2015 HighPoint Technologies, Inc. 1 Copyright Copyright 2013 HighPoint Technologies, Inc. This document

More information

SATA II-150 PCI RAID Quick Installation Guide

SATA II-150 PCI RAID Quick Installation Guide SATA II-150 PCI RAID Quick Installation Guide Introducing the SATA II-150 PCI RAID The SATA II-150 PCI RAID is an ultra high-speed two channel Serial ATA Generation II RAID controller for use in PCI enabled

More information

QuickSpecs. Compaq Smart Array 431 Controller M ODELS

QuickSpecs. Compaq Smart Array 431 Controller M ODELS M ODELS Smart Array 431 Controller 127695-B21 127695-291(Japan) Data Compatibility Software Consistency Wide Ultra3 SCSI 64-bit Architecture 64-bit PCI Bus Design Single internal/external SCSI channel

More information

IBM System Storage DS3000 Interoperability Matrix IBM System Storage DS3000 series Interoperability Matrix

IBM System Storage DS3000 Interoperability Matrix IBM System Storage DS3000 series Interoperability Matrix IBM System Storage DS3000 Interoperability Matrix - 1 - IBM System Storage DS3000 series Interoperability Matrix Last Revised: July 29, 2008 IBM System Storage DS3000 Interoperability Matrix - 2 - Table

More information

Before Reading This Manual This section explains the notes for your safety and conventions used in this manual.

Before Reading This Manual This section explains the notes for your safety and conventions used in this manual. Integrated Mirroring SAS User s Guide Areas Covered Before Reading This Manual Chapter 1 Chapter 2 Chapter 3 This section explains the notes for your safety and conventions used in this manual. Overview

More information

At a glance. Overview

At a glance. Overview ServeRAID B5015 SSD Controller is an enterprisegrade RAID adapter offering the highest performance and data protection optimized for next-generation SSDs At a glance The ServeRAID TM B5015 SSD Controller

More information

SAS e PCI Express to 12Gb/s SAS Host Bus Adapter

SAS e PCI Express to 12Gb/s SAS Host Bus Adapter SAS 9305-16e PCI Express to 12Gb/s SAS Host Bus Adapter User Guide Version 1.1 pub-005244 For a comprehensive list of changes to this document, see the Revision History. Corporate Headquarters San Jose,

More information

esata II PCIe i/e Quick Installation Guide

esata II PCIe i/e Quick Installation Guide Introduction esata II PCIe i/e Quick Installation Guide The esata II PCIe i/e is an ultra high-speed dual channel Serial ATA Generation 2 controller for use in PCI Express enabled systems. Features and

More information

ServeRAID M5110 and M5110e SAS/SATA Controllers for IBM System x IBM Redbooks Product Guide

ServeRAID M5110 and M5110e SAS/SATA Controllers for IBM System x IBM Redbooks Product Guide ServeRAID M5110 and M5110e SAS/SATA Controllers for IBM System x IBM Redbooks Product Guide The ServeRAID M5110 and M5110e SAS/SATA controllers for IBM System x are part of the IBM ServeRAID M Series family

More information

Introducing the esata II-150 PCI

Introducing the esata II-150 PCI esata II-150 PCI Quick Installation Guide Introducing the esata II-150 PCI The esata II-150 PCI is an ultra high-speed dual channel Serial ATA Generation 2 controller for use in PCI enabled systems. Features

More information

IBM Netfinity ServeRAID-3H and -3L Ultra2 SCSI Adapters

IBM Netfinity ServeRAID-3H and -3L Ultra2 SCSI Adapters Enterprise storage applications benefit from the right Ultra2 SCSI RAID Adapter IBM Netfinity and -3L Ultra2 SCSI Adapters Highlights Powerful enterprise storage adapter Power and performance matched to

More information