AS-Interface Slaves. I/O Modules for Operation in the Field. Digital I/O modules IP67 - K45

Size: px
Start display at page:

Download "AS-Interface Slaves. I/O Modules for Operation in the Field. Digital I/O modules IP67 - K45"

Transcription

1 Overview The large industry-proven K60 compact modules are complemented perfectly by the K45 compact module series. They round off the existing product range of smaller modules. The acknowledged advantages of the existing K60 compact modules can all be found in the significantly smaller K45 modules. Their base is the same size as the application modules. The mounting depth, however, is only 2/3 of that of the application module and therefore fits perfectly to the compact module series. Despite these small dimensions all modules have large labeling plates and an integrated address jack. Two mounting plates are available for the K45 compact modules: The first mounting plate has the identical hole pattern as the K60 compact modules. This allows K60 compact modules to be combined with K45 modules in a single alignment. The ribbon cables can be placed easily into the recesses of the mounting plates The hole pattern and the DIN rail mount of the application modules are integrated into the second mounting plate Installing the ribbon cables has become even easier. The yellow and black AS-Interface ribbon cable can be inserted into the mounting plates from the left or right regardless of the position of the coding pins. The correct polarity of the applied voltages is always ensured. Sensors and actuators are connected via M12 sockets. The 4E module can also be ordered with M8 connection sockets. Design Mounting Insert yellow or yellow/black AS-Interface ribbon cables into the corresponding cable channel of the mounting plate. Insert in any direction. Hook top of module into mounting plate. The top of the module can only be fixed to the mounting plate with a screw. 14/56 Siemens Energy & Automation, Inc.

2 Design (continued) Mounting options Mounting onto standard rails via mounting plate 3RK DA00. Can be mounted (horizontal and vertical mounting possible) onto commercially available mounting system via screw-on slide blocks (max. M5, not part of scope of supply) on mounting plate 3RK EA00 or 3RK DA00. Addressing Addressing via integrated addressing socket. M12 sockets which are not required must be sealed with 3RK KA00 sealing caps to comply with the specified degree of protection. Wall mounting via mounting plate 3RK EA00. Siemens Energy & Automation, Inc. 14/57

3 Technical specifications Common technical specifications of all digital I/O modules IP67 K45 Operating voltage in accordance with AS-Interface specification in V Reverse voltage protection U AS- Built-in Interface Input circuit PNP Inputs Sensor supply via AS-Interface Short-circuit and overload proof Sensors 2- and 3-conductor Voltage range in V ) Current-carrying capacity for all inputs 200 (T u 40 C) in ma Switching level "High" in V 10 Input current Low/High in ma 1.5 / 6 Outputs Type of output Electronics Short-circuit protection Built-in Inductive interference protection Built-in External power supply 24 V DC via black AS-Interface ribbon cable Watchdog Built-in AS-Interface certificate Assigned (or applied for with new devices) 1) For 3RK BQ20-0AA3 V min = 16.5 V Approvals UL, CSA, shipbuilding (or applied for with new devices) Degree of protection IP67 (IP65 with M8 snap connection) Ground connection Via PIN5 of the M12 sockets and output via a 2.8-mm flat connector (no ground connection with M8 sockets) Ambient temperature in C Storage temperature in C Status displays I/O display Yellow LED U aux display Green LED AS-Interface/diagnostics display Dual green/red LED Connection via mounting plate for K45 compact module Note 1 All K45 compact modules are supplied with stainless steel screws and sockets Note 2 An external auxiliary power supply (AUX POWER) of 20 V to 30 V DC is required to supply the output circuits. The auxiliary power supply must comply with VDE 0106 (PELV), Protection Class III 4 inputs 4 inputs 4 inputs Standard slave M12 3RK CQ20 0AA3 Standard slave M8 screw connection 3RK CT20 0AA3 Total power consumption in ma Socket assignment for inputs PIN4 + 2 = data input Standard slave M8 snap-on connection 3RK CU20 0AA3 I/O configuration ID/ID2 code 0/F 0/F 0/F Assignment of data bits Socket 1 PIN4/2 = IN1(D0) PIN4 = IN1(D0) PIN4 = IN1(D0) Socket 2 PIN4/2 = IN2(D1) PIN4 = IN2 (D1) PIN4 = IN2 (D1) Socket 3 PIN4/2 = IN3(D2) PIN4 = IN3(D2) PIN4 = IN3(D2) Socket 4 PIN4/2 = IN4(D3) PIN4 = IN4 (D3) PIN4 = IN4 (D3) Number of I/O sockets A/B slave M12 3RK CQ20 0AA3 A/B slave M8 screw connection 3RK CT20 0AA3 Total power consumption in ma Socket assignment for inputs PIN4 + 2 = data input A/B slave M8 screw connection 3RK CU20 0AA3 I/O configuration ID/ID2 code 0/F 0/F 0/F Assignment of data bits Socket 1 PIN4/2 = IN1(D0) PIN4 = IN1(D0) PIN4 = IN1(D0) Socket 2 PIN4/2 = IN2(D1) PIN4 = IN2 (D1) PIN4 = IN2 (D1) Socket 3 PIN4/2 = IN3(D2) PIN4 = IN3(D2) PIN4 = IN3(D2) Socket 4 PIN4/2 = IN4(D3) PIN4 = IN4 (D3) PIN4 = IN4 (D3) Number of I/O sockets /58 Siemens Energy & Automation, Inc.

4 Technical specifications (continued) 1) The typical current-carrying capacity per output increases from 1.5 to 2 A for Version "E12". AS-Interface Slaves 2x2 inputs 2 inputs, 2 outputs 2 x (1 input / 1 output) Current-carrying capacity of the outputs: 2 A 1 ) Current carrying capacity of the outputs: 0.2 A A/B slave Standard slave Standard slave Y assignment M12 M12 M12 3RK CQ22 0AA3 3RK BQ20 0AA3 3RK GQ20 0AA3 Total power consumption in ma Reverse voltage protection V Aux Not applicable By coding U Aux not required Socket assignment for inputs PIN4 + 2 = data input PIN2 = data input PIN3 = sensor supply L Outputs Current-carrying capacity for each ) 0,2 output DC 12/13 (typical) in A Max. summation current per ,2 module in A I/O configuration ID/ID2 code A/0 0/F F/F Assignment of data bits Socket 1 PIN4 = IN1 (D0) PIN2 = IN2 (D1) PIN4/2 = IN1(D0) Socket 2 -- PIN4/2 = IN2(D1) -- Socket 3 -- PIN4 = OUT3(D2) -- Socket 4 PIN4 = IN3 (D2) PIN2 = IN4 (D3) PIN4 = OUT4(D3) Number of I/O sockets PIN2 = output PIN3 = sensor supply L PIN4 = IN1(D0) PIN2 = OUT3(D2) PIN4 = IN2(D1) PIN2 = OUT3(D3) 4 outputs 3 outputs 2 outputs / 2 inputs Current carrying capacity of the outputs: 1 A Current carrying capacity of the outputs: 1A Current carrying capacity of the outputs: 2 A Standard slave A/B slave A/B slave M12 M12 M12 3RK CQ20 0AA3 3RK EQ20 0AA3 3RK BQ20 0AA3 Total power consumption in ma Reverse voltage protection V Aux By coding By coding By coding Socket assignment for inputs PIN2 = data input PIN3 = sensor supply L Outputs Current-carrying capacity for each output DC 12/13 (typical) in A Max. summation current per module in A I/O configuration 8 8 B ID/ID2 code 0/F A/0 A/0 Assignment of data bits Socket 1 PIN4 = OUT1 (D0) PIN4 = OUT1 (D0) PIN4/2 = IN3(D2) Socket 2 PIN4 = OUT2 (D1) PIN4 = OUT2 (D1) PIN4/2 = IN4(D3) Socket 3 PIN4 = OUT3(D2) PIN4 = OUT3(D2) PIN4 = OUT1 (D0) Socket 4 PIN4 = OUT4(D3) not available PIN4 = OUT2 (D1) Number of I/O sockets Siemens Energy & Automation, Inc. 14/59

5 Technical specifications (continued) K45 mounting plate Distributors Cable end element for wall mounting for standard mounting rail mounting 3RK EA00 3RK DA00 3RK NN00 3RK MN00 Ambient temperature in C Degree of protection IP67 with screwed-on K45 compact module IP67 with screwed-on K45 compact module IP65 with screwed-on top part IP67 with inserted shaped AS-Interface cable Connections Installation Note For shaped AS-Interface cable, contacting through insulation displacement terminations integrated in the compact module Wall mounting On profile system (the corresponding slot parts are required) Hole grid compatible with K60 mounting plate Introduction of yellow and black AS-Interface cables possible from any direction For shaped AS-Interface cable, contacting through insulation displacement terminations integrated in the compact module Standard mounting rail/wall mounting On profile system (the corresponding slot parts are required) Hole grid compatible with FK/FK-E coupling module (user module) Introduction of yellow and black AS-Interface cables possible from any direction For profiled AS-Interface cable, yellow or black, contacting through insulation displacement terminations integrated in the top part Standard mounting rail/wall mounting On profile system (the corresponding slot parts are required) Hole grid compatible with FK/FK-E coupling module (user module) The distributor can be used for the following functions: Design of network structures (feeder function) Division of cable segments (separating function) Sealing of cable ends in the module (sealing function) If one or both of the cables is to terminate in the distributor, seals (straight and shaped) are required and are inserted in the bottom part of the distributor. These seals are not included in the scope of delivery, and must be ordered separately (3RK AR00). No additional seals are required if both cables are routed completely through the module. PG screwed gland with integral seal (seal with profile for AS-Interface cable) Cable end element can be secured e.g. on a machine using an integral lug -- 14/60 Siemens Energy & Automation, Inc.

6 Selection and Ordering data 3RK GQ20 0AA3 Accessories AS-Interface Slaves Version Order No. List Price $ PNP transistor Current-carrying capacity of the inputs: 200 ma Modules supplied without mounting plate Type Current car-slavrying type Pin Connections assignment capacity of the outputs 4 inputs -- Standard Standard M12 3RK CQ20-0AA M8 screw 3RK CT20-0AA M8 snap-mount 3RK CU20-0AA A/B M12 3RK CQ20-0AA M8 screw 3RK CT20-0AA M8 snap-mount 3RK CU20-0AA x 2 inputs -- A/B Y M12 3RK CQ22-0AA inputs / 2 outputs 2 A 1 ) Standard Standard 3RK BQ20-0AA x (1 input / 1 output) 0.2 A Y 3RK GQ20-0AA outputs 1 A Standard 3RK CQ20-0AA outputs A/B 3RK EQ20-0AA outputs / 2 inputs 2 A 3RK BQ20-0AA K45 mounting plate for wall mounting 3RK EA for mounting rails 3RK DA RK EA00 Distributors for AS-Interface ribbon cables Supplied with special mounting plate for wall and DIN rail mounting Seals (3RK AR00) are only required if a cable is to terminate in the distributor box. The seals must be ordered separately if required. 3RK NN RK NN00 3RK KA00 AS-Interface sealing caps for free M12 sockets 3RK KA for free M8 sockets 3RK PN RK PN00 Cable end piece for sealing open cable ends (trapezoidal AS-Interface cable) in IP67 3RK MN RK MN00 Sealing set for K60 mounting plate and distributor Cannot be used for K45 mounting plate (each set contains one straight and one trapezoidal seal) 3RK AR RK AR00 1) The typical current-carrying capacity per output increases from 1.5 to 2 A for Version "E12". Siemens Energy & Automation, Inc. Discount Code: AS-Interface 14/61

7 Dimension drawings Mounting plate for wall fixing lug 3RK EA00 Same drill pattern and mounting options as K60 compact module Distributor 3RK NN00 Mounting plate for DIN rail mount 3RK DA00 Same drill pattern and mounting options as application module Distributor 3RK NN00 Schematics Connector pin assignment input, pnp (M8 socket) Connector pin assignment input, pnp (M12 socket) 14/62 Siemens Energy & Automation, Inc.

8 Schematics (continued) Connector pin assignment input, pnp (M12 socket) Connector pin assignment output, pnp (M12 socket) 24 V DC Y assignment Siemens Energy & Automation, Inc. 14/63

AS-Interface I/O Module

AS-Interface I/O Module AS-Interface I/O Module Construction The AS-Interface I/O module is designed as a compact, robust field module. It is composed of an electronic module (top) and a coupler module (base). Connectors (standard

More information

Actuator-Sensor-Interface

Actuator-Sensor-Interface Overview Pin assignment 3RG9 002-0D.00 3RG9 004-0D.00 3RG9 002 0DE00 3RG9 004 0DE00 Assignment of the screw terminals/ Combicon pin connectors with F9 modules (4I/4O) Functions Principle of operation of

More information

Switches 6/1. 6/4 Introduction. 6/5 5TE8 control switches. 6/7 5TE4 8 pushbuttons. 6/9 5TE8 On/Off switches. 6/11 5TE1 switch disconnectors

Switches 6/1. 6/4 Introduction. 6/5 5TE8 control switches. 6/7 5TE4 8 pushbuttons. 6/9 5TE8 On/Off switches. 6/11 5TE1 switch disconnectors 6/4 Introduction 6/5 5TE8 control switches 6/7 5TE4 8 pushbuttons 6/9 5TE8 On/Off switches 4 6/11 5TE1 switch disconnectors 6 6/1 Switch to manual? Wherever electrical systems need to be switched on or

More information

Siemens AG SENTRON 3NJ4, 3NJ5 In-Line Fuse Switch Disconnectors up to 2000 A

Siemens AG SENTRON 3NJ4, 3NJ5 In-Line Fuse Switch Disconnectors up to 2000 A Switch Disconnectors Introduction Overview All key product features at a glance Compliant with IEC/EN 60439-1, IEC/EN 6094-3 Voltage levels up to 690 V AC Rated operational current from 160 A to 2000 A

More information

Sensor boxes SRBG Key features

Sensor boxes SRBG Key features Key features Function SRBG sensor boxes are the compact solution when it comes to electrical feedback signals and monitoring the position of process valves which are actuated with pneumatic quarter turn

More information

TABLE OF CONTENTS AS-INTERFACE

TABLE OF CONTENTS AS-INTERFACE TABLE OF CONTENTS AS-Interface module AAAA...2 AS-Interface module EEAA...4 AS-Interface module EEEE...6 AS-Interface coupler module PGK...8 AS-Interface coupler module FKK...10 AS-Interface coupler module

More information

Miniature Inductive Prox TL-W

Miniature Inductive Prox TL-W Miniature Inductive Prox Subminiature, Flat-Pack DC Sensor Fits Tight Spaces Watertight construction conforms to IP67 Space-saving mounting area, as small as 10 x 27 mm ( 0.39 x 1.06 in), is ideal for

More information

SX5A AS-Interface(Communication Terminal and Repeater)

SX5A AS-Interface(Communication Terminal and Repeater) SXA AS-Interface(Communication Terminal and Repeater) AS-Interface Communication Terminals (Slave Modules) IP67 I/O Module AS-Interface Ver..1 compliant, capable of connecting 6 slaves Compatible with

More information

SITOP in the SIMATIC Design

SITOP in the SIMATIC Design Siemens AG 2017 /2 Introduction /3 1-phase, 24 V DC (for S7-300 and ET 200M) /9 1-phase, 24 V DC (for S7-1200) /11 1-phase, 24 V DC (for S7-1500 and ET 200MP) /14 3-phase, 24 V DC (ET 200pro) Siemens KT

More information

Analog Modules AS-i, IP67, M12

Analog Modules AS-i, IP67, M12 Analog Modules, M12 2 x 2 connectors for compact housing, IP67 (Figure similar) Figure Type Inputs analog Outputs analog M12 connection Input voltage (sensor supply) Output voltage (actuator supply) (2)

More information

Energetic diffuse reflection light scanner. Dimensioned drawing

Energetic diffuse reflection light scanner. Dimensioned drawing Energetic diffuse reflection light scanner Dimensioned drawing We reserve the right to make changes 93_c3gb.fm Part No. 51 1168 1-3 V DC 5 17mm 1mm Infrared light Background suppression through appropriate

More information

Surface-Mounting Product Ranges

Surface-Mounting Product Ranges Introduction Overview Light signals SCHUKO socket outlets Two-circuit switches Garages, laundry rooms, laboratories and workshops are often exposed to a lot of heavy-duty activity, which includes the odd

More information

Special-Purpose Proximity Sensor E2C

Special-Purpose Proximity Sensor E2C Special-Purpose Proximity Sensor E2C Cylindrical Inductive Sensors with Separate Amplifiers Provide Variable Detecting Capabilities Separate amplifier allows sensor to fit in space-confined sites, providing

More information

TROXNETCOM AS-i. Modules. Communication interface between a component and the controller. 06/2015 DE/en K

TROXNETCOM AS-i. Modules. Communication interface between a component and the controller. 06/2015 DE/en K .2 X X testregistrierung TROXNETCOM AS-i Communication interface between a component and the controller The module is used to connect the control system with the components Integral AS-Interface slave

More information

Communication & Networking

Communication & Networking SXA AS-Interface SXA AS-Interface (Communication Terminal and Repeater) AS-Interface Communication Terminals (Slave Modules) IP67 I/O Module AS-Interface Ver.. compliant, capable of connecting 6 slaves

More information

Siemens AG RA6 Fuseless Compact Starters. Catalog News LV 1 N April 2008 SIRIUS.

Siemens AG RA6 Fuseless Compact Starters. Catalog News LV 1 N April 2008 SIRIUS. 3RA Fuseless Compact Starters Catalog News LV 1 N April 2008 SIRIUS www.siemens.com/lowvoltage 3RA Fuseless Compact Starters General data Overview 3RA fuseless compact starters and infeed system for 3RA

More information

ML17 Series Tru-Vue TM Sensors

ML17 Series Tru-Vue TM Sensors ML7 Series Tru-Vue TM Sensors Diffuse Mode with Background Suppression See page 44 Features: Ver low color sensitivit Tamper-proof housing with no eternal adjustments Sensing Range: 5 mm Output: 4-in-

More information

AS-i / IO-Link Module, IO-Link Master with 4 IO-Link Ports

AS-i / IO-Link Module, IO-Link Master with 4 IO-Link Ports / IO-Link Module, /IO-Link Module, IO-Link Master with 4 s fourfold IO-Link Master in one housing Power supply of s (or ) (Figure similar) Figure Type Inputs digital 4 x + 4 x + 4 x Outputs digital M12

More information

Digital Modules AS-i in IP20, 22,5 mm

Digital Modules AS-i in IP20, 22,5 mm Digital Modules AS-i in 22,5 mm Cost efficient solution in IP20 (Figure similar) Figure Type Housing s digital digital voltage (sensor supply) (1) Output voltage (actuator supply) (2) AS-i connection (3)

More information

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005 Product and Applications Description Application Programs The application programs of the dimmer UP 525/01 consist of two elements: the actuating and the sensor program element. The tasks actuating program

More information

Thermal-Magnetic Circuit Breaker 2216-S

Thermal-Magnetic Circuit Breaker 2216-S Thermal-Magnetic Circuit Breaker 226-S Description One and two pole thermal-magnetic circuit breaker in compact design with slide actuator, trip-free mechanism, various trip characteristics and optional

More information

Routers. DP/AS-i F-Link 2/41. Overview

Routers. DP/AS-i F-Link 2/41. Overview Siemens AG 014 Routers DP/AS-i F-Link DP/AS-i F-Link The DP/AS-i F-Link is a compact, safety-related router between PROFIBUS (DP Slave) and, with the following features: Monitoring the inputs of safety-related

More information

Miniature Inductive Prox TL-W

Miniature Inductive Prox TL-W Miniature Inductive Prox Subminiature, Flat-Pack DC Sensor Fits Tight Spaces Watertight construction conforms to IP67 Space-saving mounting area, as small as 10 x 27 mm ( 0.39 x 1.06 in), is ideal for

More information

AS-i Safety Input Modules (M12), IP67

AS-i Safety Input Modules (M12), IP67 Input Modules (), IP67 Input Modules (), IP67 for opto, floating contacts or complementary switch Applications up to category 4/PLe/SIL 3 (Figure similar) Figure Type Inputs, SIL 3, cat. 4 4 x, 4 x, 4

More information

Diffuse reflection light scanner with background suppression. Dimensioned drawing

Diffuse reflection light scanner with background suppression. Dimensioned drawing Specifications and description HRTR 3B Standard Dimensioned drawing We reserve the right to make changes DS_HRTR3B_Standard_en_51734.fm en 13-213/3 51734 1-3 V DC 1 khz A 2 LS 5 4mm 2mm with black-white

More information

Temperature Switches

Temperature Switches ETS 00 Series Temperature Switch for Inline and Tank Mounting Applications Description The ETS 00 is a compact electronic temperature switch with 4-digit digital display. Pressure resistant to 8700 psi,

More information

Operating instructions ClassicLine module AC5204 / AC5209 / AC5212 AC5235 / AC5236 / AC5237 AC /00 07/2017

Operating instructions ClassicLine module AC5204 / AC5209 / AC5212 AC5235 / AC5236 / AC5237 AC /00 07/2017 Operating instructions ClassicLine module AC5204 / AC5209 / AC5212 AC5235 / AC5236 / AC5237 AC5274 7390889/00 07/2017 Contents 1 Functions and features...3 2 Operating and display elements...3 3 Installation...4

More information

Air gap sensors SOPA

Air gap sensors SOPA Product range overview Key features General Lightweight, compact and highly precise, this pneumatic solution offers impressive scope for integration: SOPA features a control module, compressed air regulation,

More information

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection NCN-FK-N-V-V 002 Model Number NCN-FK-N-V-V Features Direct mounting on standard actuators Compact and stable housing with terminal compartment connection Fixed setting EC-Type Examination Certificate TÜV99

More information

Technical Data. General specifications. Rated operating distance s n 3 mm

Technical Data. General specifications. Rated operating distance s n 3 mm 0102 Model Number Features Direct mounting on standard actuators Compact and stable housing with terminal compartment connection ATEX & IECEX certifications Usable up to SIL 2 acc. to IEC 61508 Weatherproof

More information

E3X-NA. Adjuster type standard that is the culmination of true ease and simplicity. Super Manual Fiber Amplifier. Features

E3X-NA. Adjuster type standard that is the culmination of true ease and simplicity. Super Manual Fiber Amplifier. Features Super Manual Fiber Amplifier Adjuster type standard that is the culmination of true ease and simplicity Features Self-explanatory LED bar displays of light levels The previous manual type used the stability

More information

Thermal-Magnetic Circuit Breaker 4220-T...

Thermal-Magnetic Circuit Breaker 4220-T... Thermal-Magnetic Circuit Breaker 40-T... Description Single, double and three pole thermal-magnetic circuit breakers with high rupture capacity to UL 489 (5 ka), EN/IEC 60934 (6kA) and UL 077 (5 ka). With

More information

Two-stage lifting column - RKSlimlift /EM

Two-stage lifting column - RKSlimlift /EM Two-stage lifting column - RKSlimlift /EM Rod-shaped design and extremely quiet operation RKSlimlift RKSlimlift EM 4 fixing threads Simple connection Drive above the internal profile Large assembly surface

More information

3081 Test Leads Test Leads Test Leads

3081 Test Leads Test Leads Test Leads 3081 Test Leads 4 mm safety plug system PVC-lead highly flexible, 0.8 mm 2 Safety plug at both ends Straight/angled, complying with Standard cable length: 500/1000/2000 mm Test Leads with Silicon-Isolation

More information

Compact performance. Brief description. CPV valve terminal with AS-Interface type CPV..-GE- ASI-8E8A-Z M8. English e [ ]

Compact performance. Brief description. CPV valve terminal with AS-Interface type CPV..-GE- ASI-8E8A-Z M8. English e [ ] Compact performance Brief description CPV valve terminal with AS-Interface type CPV..-GE- ASI-8E8A-Z M8 English 8080251 2017-11e [8080244] Translation of the original instructions Documentation on the

More information

5/2 and 5/3 Directional-control valves, Series TC 15, G 1/4

5/2 and 5/3 Directional-control valves, Series TC 15, G 1/4 5/2 and 5/3 Directional-control valves, Series TC 15, G 1/4 Products 5/2 Directional-control valve, single valve, electrical connection M8 (4 poles) 5/3 Directional-control valve, single valve, electrical

More information

QUINT-PS AC/24DC/10

QUINT-PS AC/24DC/10 Extract from the online catalog QUINT-PS-100-240AC/24DC/10 Order No.: 2938604 DIN rail power supply unit 24 V DC/10 A, primary switched-mode, 1- phase Commercial data EAN 4017918890537 Pack 1 Pcs. Customs

More information

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors UL Recognized C60N Supplementary Protectors B Curve C60N Supplementary Protectors 1 MG24110 MG24125 MG24140 MG24155 15 MG17406 MG17436 MG17461 1.2 MG17402 MG17432 16 MG24118 MG24133 MG24148 MG24163 1.5

More information

NRG Series Parallel Gripper

NRG Series Parallel Gripper NRG Series Parallel Gripper www.numatics.com Table of Contents NRG Series Features and Benefits 3 How To Order 4 Dimensions 5 Specifications and Load Ratings 6 NuMate Mounting System 7 Grippers 7 Sensing

More information

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m.

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m. Built-in Amplifier (Medium Size) ES-A Be sure to read Safety Precautions on page 0. Ordering Information Built-in Amplifier s Red light Infrared light Sensing method Appearance Connection method Sensing

More information

Safety System CES-FD. Non-contact safety system CES-FD- Direct connection to decentralized peripheral systems (e.g. ET200pro) PLC

Safety System CES-FD. Non-contact safety system CES-FD- Direct connection to decentralized peripheral systems (e.g. ET200pro) PLC Non-contact safety system CES-FD- Evaluation of signals in the field Connection of CES read heads Connection to the ET200s and ET200pro Familiar EUCHNER AP interface Functional description Field evaluation

More information

JUMO PINOS L01. Calorimetric flow sensor. Brief description. Special features. Customer benefits. Data Sheet

JUMO PINOS L01. Calorimetric flow sensor. Brief description. Special features. Customer benefits. Data Sheet sales@jumo.co.uk info.us@jumo.net Page 1/9 JUMO PINOS L01 Calorimetric flow sensor Brief description The JUMO PINOS L01 flow sensor serves the measuring and monitoring of flow velocities of water and aqueous

More information

Absolute Encoders Multiturn

Absolute Encoders Multiturn The multiturn encoders 5868 and 5888 with interface and optical sensor technology are ideal for use in all applications with a interface. The encoder supports the isochronous (IRT) mode and is therefore

More information

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m.

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m. Built-in Amplifier (Medium Size) ES-A CSM_ES-A_DS_E Be sure to read Safety Precautions on page 0. Ordering Information Built-in Amplifier s Red light Infrared light Sensing method Appearance Connection

More information

1 - Control and signalling units

1 - Control and signalling units Contents 0 - Control and signalling units Selection guide..............................................page /2. Control and signalling units Ø 8 et 2 b LED pilot lights, type XVL A...................................

More information

Contact protection relay

Contact protection relay Contact protection relay Ordering details SVR 450 08 F0000 The protects sensitive control contacts from excessive load. It can be used with latching function or without. Bounce time of control contacts

More information

3RV1 Circuit-Breakers

3RV1 Circuit-Breakers SIRIUS 3R Description Mountable accessories 3RV1 Circuit- Breakers Circuit-breaker S00 with mountable accessories 3 2 1 5.1 NSK-7715a 4 Circuit-breaker S0 with mountable accessories 1 7 3 5.2 2 6 NSK-7716a

More information

Technical data. General specifications. factory setting: 125 ms Memory Non-volatile memory Write cycles Indicators/operating means

Technical data. General specifications. factory setting: 125 ms Memory Non-volatile memory Write cycles Indicators/operating means Model Number Single head system Features IO-link interface for service and process data Programmable via DTM with PACTWARE Switch output and analog output Selectable sound lobe width Synchronization options

More information

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog Issued February 2011 DATA SHEET 5SX2 MCB Based on Siemens Industrial Control Catalog General Data Trip characteristics Tripping characteristics acc. to EN 60 898 Tripping characteristic A, -5 Type A characteristic

More information

Siemens AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE AMBERG, GERMANY

Siemens AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE AMBERG, GERMANY Issued to: Siemens AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE 48 92220 AMBERG, GERMANY This is to certify that Auxiliary Devices representative samples of 3UF70 followed by 0 or 1 followed by 0

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-T...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-T... Description ngle, two and three pole magnetic and hydraulic-magnetic circuit breakers with trip-free mechanism and toggle actuation. A choice of fast magnetic only hydraulically delayed switching characteristics

More information

1 open / 1 close, 240 V ac / 2 A. < 70 ma < 65 ma ac 20 Hz 13 Hz dc 72 Hz 25 Hz

1 open / 1 close, 240 V ac / 2 A. < 70 ma < 65 ma ac 20 Hz 13 Hz dc 72 Hz 25 Hz Description Operation mode and max sensing range: Diffuse proximity: 0-5 m Background suppression: 0- m Compact rectangular housing (x mm) Cable or rotatable plug connection via potentiometer Switch selectable

More information

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016 Operating instructions AS-i SmartLine module AC3200 AC3201 80237876/00 06/2016 Contents 1 Preliminary note...3 1.1 Symbols used...3 1.2 Warnings used...3 2 Safety instructions...3 2.1 General...3 2.2 Target

More information

Digital electropneumatic positioner

Digital electropneumatic positioner Digital electropneumatic positioner Type 879 can be combined with Compact metal housing Graphic display with backlight Easy start-up Comprehensive range of additional software functions Profibus DPV1 (optional)

More information

Operating instructions valve control box AS-i

Operating instructions valve control box AS-i THIS LEAFLET SHOULD BE KEPT IN A SAFE PLACE FOR REFERENCE Operating instructions valve control box AS-i 1 System description The Norgren Herion valve control box is used for controlling pneumatic swivel

More information

Flow sensors SFAB Key features

Flow sensors SFAB Key features Key features At a glance Quick and secure installation thanks to QS fitting Display can be rotated 270 Manifold assembly of the sensor via H-rail or individual assembly via adapter plate for wall mounting

More information

4.8 Digital Input/Output Module 07 DC 92 Contents Intended purpose Displays and operating elements on the front panel Electrical connection

4.8 Digital Input/Output Module 07 DC 92 Contents Intended purpose Displays and operating elements on the front panel Electrical connection 4.8 Digital Input/Output Module 07 DC 9 3 configurable digital inputs/outputs, 4 V DC, electrically isolated in groups, outputs can be loaded with 500 ma, CS31 system bus 1 3 4 1 Fig. 4.8-1: Digital input/output

More information

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING Product and Applications Description Note If the application program is not loaded completely by the ETS, you had better interrupt the 24 V voltage supply of the I/O-module during the loading interval.

More information

AS-Interface. I/O modules for use in the control cabinet. AS-Interface SlimLine Compact Modules. Gerätehandbuch. siemens.com.

AS-Interface. I/O modules for use in the control cabinet. AS-Interface SlimLine Compact Modules. Gerätehandbuch. siemens.com. AS-Interface I/O modules for use in the control cabinet Gerätehandbuch Manual Edition 10/2015 siemens.com AS-Interface SlimLine Compact Modules AS-Interface I/O modules for use in the control cabinet

More information

SR60 Busbar System 2/1 2/2. General Data. 2/3 Busbar routing. 2/7 Mounting components. 2/13 Accessories

SR60 Busbar System 2/1 2/2. General Data. 2/3 Busbar routing. 2/7 Mounting components. 2/13 Accessories / SR0 Busbar System General Data / Busbar routing / Mounting components / Accessories / SR0 Busbar System General Data Overview The SR0 busbar system is a modular system for busbars, for installation in

More information

GR Series Adjustable Angular Gripper

GR Series Adjustable Angular Gripper GR Series Adjustable Angular Gripper www.numatics.com Table of Contents GR90 Series Angular Grippers Features & Benefits 3 How to Order 3 Dimensions 4 Technical Specifications 5 Switch Information 6 Quick

More information

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex-zone 20 for temperatures up to -25 C SIL2 acc. to IEC 61508 Rectangular, housing DSU35 Plastic, PP-GF30-VO Two outputs for monitoring the position

More information

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors B Curve NC100H Supplementary Protectors Rating 1P 2P 3P 4P 80 MG27164 MG27175 MG27186 MG27197 MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors C Curve NC100H Supplementary Protectors

More information

Oil-resistive, Long-range Photoelectric Sensor with Metal Housing

Oil-resistive, Long-range Photoelectric Sensor with Metal Housing Oil-resistive, Long-range with Metal Housing ES-C Water- and Oil-resistive with Metal Housing Used for Long-range Sensing Satisfies the water- and oil-resistive requirements and safe enough for use in

More information

Control Head for the integrated mounting on process valves

Control Head for the integrated mounting on process valves Control Head for the integrated mounting on process valves Type 8691 can be combined with Compact stainless steel design Integrated analogue valve position registration (Teach function) Coloured illuminated

More information

QUINT-PS/1AC/24DC/10. Extract from the online catalog. Order No.:

QUINT-PS/1AC/24DC/10. Extract from the online catalog. Order No.: Extract from the online catalog QUINT-PS/1AC/24DC/10 Order No.: 2866763 DIN rail power supply unit 24 V DC/10 A, primary-switched mode, 1- phase. The SFB technology (Selective Fusebreaking Technology)

More information

the Interactive Catalog

the Interactive Catalog Interactive Catalog Supplements Catalog PDFs If you need detailed product information, or help choosing the right product for your application, see our Interactive Catalog Use the Interactive Catalog to

More information

Pile Driver Weld Immune Sensors

Pile Driver Weld Immune Sensors DC... 190 8, 12, 18, and 30 mm Diameter... 190 3- and 4-Wire DC... 192 8, 12, 18, and 30 mm Diameter... 192 AC/DC... 194 12, 18, and 30 mm Diameter... 194 Pile Driver Sensors P+F s weld immune Pile Driver

More information

ML20 Series Long-Range Miniature Sensors

ML20 Series Long-Range Miniature Sensors Diffuse Mode See pages 486-487 Features: Cross-talk immune for 2 units Divergent beam versions available Sensing Ranges: mm, 1 m Output: NPN, PNP Thru-Beam Mode See page 489 Features: Alignment in lens

More information

5 Fieldbus Technology

5 Fieldbus Technology 5 Fieldbus Technology Ex e / Ex i 10922E00 The s Ex e/ex i connect intrinsically safe Foundation Fieldbus H1 or Profibus PA field devices to a non-intrinsically safe / Ex e trunk. Up to four intrinsically

More information

Absolute Encoders Multiturn

Absolute Encoders Multiturn The Sendix multiturn encoders 5868 and 5888 with CANopen or CANlift interface and optical sensor technology are the right encoders for all CANopen or CANlift applications. With a maximum resolution of

More information

Solid-State Switching Devices

Solid-State Switching Devices Controls Solid-State Switching Devices /2 Introduction Solid-State Switching Devices /3 General data Solid-State Switching Devices for Resistive Loads /5 General data Solid-State Relays /7 General data

More information

Sensor boxes SRBC. Festo core product range Covers 80% of your automation tasks

Sensor boxes SRBC. Festo core product range Covers 80% of your automation tasks Sensor boxes SRBC q/w Worldwide: Superb: Easy: Festo core product range Covers 80% of your automation tasks Always in stock Festo quality at an attractive price Reduces procurement and storing complexity

More information

CATALOGUE CAPACITIVE SENSORS KXS

CATALOGUE CAPACITIVE SENSORS KXS CATALOGUE CAPACITIVE SENSORS KXS 2 For all transactions the newest version of "General Conditions of Sale and Delivery for Products and Services of the Electrical Industry ZVEI" shall apply, with the supplementary

More information

Control Circuit Components

Control Circuit Components Control Circuit Components, IO Link I/O Modules for Operation 6/2 Introduction in the Control Cabinet, IP20 6/2 Transmission technology 6/101 Introduction 6/3 Configuration examples 6/102 SlimLine 6/4

More information

Product and functional description

Product and functional description Product and functional description The RS 525/23 Universal Dimmer is a KNX device with one dimmer output. The device is installed in an AP 118 Control Module Box or an AP 641 Room Control Box. The bus

More information

MOXA EtherDevice Switch & PoE Splitter

MOXA EtherDevice Switch & PoE Splitter MOXA EtherDevice Switch & PoE Splitter EDS-P308 & SPL-24 Hardware Installation Guide First Edition, July 2006 Moxa Networking Co., Ltd. Tel: +886-2-2910-1230 Fax: +886-2-2910-1231 www.moxa.com support@moxanet.com

More information

3RA13, 3RA14 Contactor Assemblies

3RA13, 3RA14 Contactor Assemblies RA1, RA Contactor Assemblies RA1 complete units,... kw Overview The RA1 reversing contactor assemblies can be ordered as follows: Sizes S00 to S Fully wired and tested, with mechanical and electrical interlock

More information

Load Feeders, Motor Starters and Soft Starters

Load Feeders, Motor Starters and Soft Starters Load Feeders, Motor Starters and Soft Starters Catalog Technical Information 3RA Fuseless Compact Starters /2 General data /2 - Overview /3 - Benefits 3RA1, 3RA2 Compact Starters /4 3RA1 direct-on-line

More information

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Rectangular, housing DSU35 Plastic, PP-GF30-VO Two outputs for monitoring the position of rotary actuators Mounting

More information

Photoelectric Sensors E3F2

Photoelectric Sensors E3F2 Photoelectric Sensors E3F2 Threaded Cylindrical Photoelectric Sensors with Built-in Amplifier for Use as an Optical Proximity Switch M18 DIN-sized cylindrical housing Housing materials: plastic, nickel

More information

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs Product and Applications Description Example of Operation dimmer UP 525/11 load circuit AC 230 V L1 N The dimmer UP 525/11 is a dimming actuator for mounting in box mounts (a.o. 60 mm Ø, 60 mm depth).

More information

AS-i / IO-Link Module, IO-Link Master with 4 IO-Link Ports

AS-i / IO-Link Module, IO-Link Master with 4 IO-Link Ports / IO-Link Module, /IO-Link Module, IO-Link Master with 4 s fourfold IO-Link Master single in one housing Power supply of s out of AUX (or ) Figure Type Inputs digital 8x M 8x M 4 x + 4 x + Outputs digital

More information

QUINT-DC-UPS/24DC/10. Extract from the online catalog. Order No.:

QUINT-DC-UPS/24DC/10. Extract from the online catalog. Order No.: Extract from the online catalog QUINT-DC-UPS/24DC/10 Order No.: 2866226 Uninterruptible power supply 24 V DC/10 A, with integrated 1.3 Ah battery module. In the download area, there is a clearly arranged

More information

Ultrasonic sensors Discrete output Analog output

Ultrasonic sensors Discrete output Analog output Analog output General information Switch or analog outputs Sensing distances up to 6m Stainless steel housing Quick disconnect Index Discrete.... Analog....6 Technical data....8 AC 00 0/98 ULTRASONIC :

More information

QUINT-DC-UPS/24DC/10. Extract from the online catalog. Order No.:

QUINT-DC-UPS/24DC/10. Extract from the online catalog. Order No.: Extract from the online catalog QUINT-DC-UPS/24DC/10 Order No.: 2866226 Uninterruptible power supply 24 V DC/10 A, with integrated 1.3 Ah battery module. In the download area, there is a clearly arranged

More information

AS-i 3.0 motor module

AS-i 3.0 motor module 3.0 motor module 3.0 motor module for two 4 V motorized rollers Itoh Denki (PM00ME/XE/XP, PM60ME/XE/XP) with 4 binary and analog outputs Mixed input/output slave Speed setting of parameter Protection category

More information

3RP, 7PV Timing Relays

3RP, 7PV Timing Relays 3RP, PV Timing Relays Overview Standards The timing relays comply with: EN 6021-3-3 "Environmental conditions" EN 61812-1/DIN VDE 0435 Part 2021 "Solid-state relays, timing relays" EN 61000-6-2 and EN

More information

Connectors DIN 41612/IEC

Connectors DIN 41612/IEC Connectors DIN 41612/IEC 60603-2 and completions General information The DIN 41612/IEC 60603-2 connector family consists of 13 basic sizes and many complementary versions. It was developed for use in 19"

More information

Digital electropneumatic positioner

Digital electropneumatic positioner Digital electropneumatic positioner Type 879 can be combined with Compact metal housing Graphic display with backlight Easy start-up Comprehensive range of additional software functions Profibus DPV1 (optional)

More information

DIGITAL DISPLAY. for Industry Applications. Series WAY-SSI. Key-Features:

DIGITAL DISPLAY. for Industry Applications. Series WAY-SSI. Key-Features: DIGITAL DISPLAY for Industry Applications Series WAY-SSI Key-Features: Content: Technical Data.2 Technical Drawing...2 Electrical Connection...3 Description...4 Order Code & Accessories...6 - WAY-SSI-S:

More information

Solid State Remote Power Controller E

Solid State Remote Power Controller E Description The E-T-A is a transistorised switching device providing both protection and signalisation. It is suitable for all applications where the capabilities of the existing PLC s are not sufficient

More information

Inductive sensor For rotary actuators NI4-DSU35-2Y1X2-H1140

Inductive sensor For rotary actuators NI4-DSU35-2Y1X2-H1140 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Industrial Controls Product Catalog RA64 / 3RA65 up to 32 A for mounting rail, surface,

Industrial Controls Product Catalog RA64 / 3RA65 up to 32 A for mounting rail, surface, Combination Starters Industrial Controls Product Catalog 2017 Section c o n t e n t s Self Protected Motor Starters per UL 508 Type E 3RA6 3RA61 / 3RA62 up to 32 A for mounting rail, surface, comb busbar,

More information

Analog Modules AS-i IP65, M12

Analog Modules AS-i IP65, M12 Plug and Play as simply as digital AS-i I/O BWU1361 / BWU1362 / BWU1722 / BWU1853 / BWU1917 / BWU1363 / BWU2532 / BWU1359 / BW1360 / BWU1893 BWU1894 BWU1895 BWU1963 BWU1964 Housing, construction: IP65,

More information

Extract from the online catalog

Extract from the online catalog Please note that the data given here has been taken from the online catalog. For comprehensive information and data, please refer to the user documentation at http://www.download.phoenixcontact.com. The

More information

Thread length (overall length) material

Thread length (overall length) material Cylindrical Proximity Sensor for Mobile Usage Designed and tested to keep your machines moving IP69k tested and certified for highest water resistance e1 type approval (according to automotive directive

More information

Solid-State Contactors

Solid-State Contactors Solid-state contactors for switching motors The solid-state contactors for switching motors are intended for frequently switching on and off three-phase current operating mechanisms up to 7.5 kw and reversing

More information

4 COMBINATION SIRIUS. SIRIUS 3RA6 Compact Starters 4/2. General data

4 COMBINATION SIRIUS. SIRIUS 3RA6 Compact Starters 4/2. General data Combination Starters Industrial Controls Product Catalog 2019 Section contents Self Protected Motor Starters per UL 508 Type E RA6 RA61 / RA62 up to 2 A for mounting rail, surface, comb busbar, infeed

More information

Safety Switches CES-AR/CET-AR

Safety Switches CES-AR/CET-AR CES-A-L XXXXXX Safety Switches Component overview for non-contact safety switches Connection cable Safety switch Actuator Bolt CES-A-BBA Page 1 CES-A-BCA Page 1 Page 10 CES-AR-C01-... Page 10 CES-A-BPA

More information