EE80 Series. HVAC Room Transmitter and Switches for CO 2, Relative Humidity and Temperature EE80. Applications. Typical
|
|
- Lily Hopkins
- 6 years ago
- Views:
Transcription
1 EE80 Series HVAC Room Transmitter and Switches for, Relative Humidity and Temperature EE80 series set new standards in measurements for HVAC. The transmitters resp. switches combine, relative humidity (RH) and temperature (T) measurement in one modern and userfriendly housing. The basic EE80 version for and T can be easily extended with a RH plug-in module. The measerument is based on the infrared principle. A patented auto-calibration procedure compensates for the aging of the infrared source and ensures outstanding long term stability. EE80 provides analogue outputs (in V or ma). The optional display indicates sequentially the actual measuring data. As one more option a switching output with adjustable switching point and hysteresis is available. A wide variety of models ensures an optimal adjustment for customised requirements. EE80 Typical Applications building management for residential and office areas ventilation control Technical Data Measuring values Measurement principle Non-Dispersive Infrared Technology (NDIR) Sensor E+E Dual Source Infrared System Working range ppm ppm Accuracy at 20 C (68 F) ppm: < ± (50ppm +2% of measuring value) and 1013mbar ppm: < ± (50ppm +3% of measuring value) Response time t 63 < 90 sec Temperature dependence typ. 2ppm / C Long term stability typ. 20ppm / year Sample rate ca. 0.5 min Relative Humidity Measurement principle capacitive Sensor element HC103 Working range 1) % RH Accuracy at 20 C (68 F) ±3% RH ( % RH) ±5% ( % RH) Temperature Accuracy at 20 C (68 F) ±0.3 C (±0.54 F) version with current output 4-20mA: ±0.7 C (±1.26 F) Outputs /5000 ppm / % RH / 0-5V -1mA < I L < 1mA C ( F) 0-10V -1mA < I L < 1mA 4-20mA R L < 500 Ohm Max. switching voltage 50V AC / 60V DC Max. switching load 1A at 50V AC 1A at 30V DC Min. switching load 1mA at 5V DC Contact material Ag+Au clad General Supply voltage SELV 24V AC ±20% 15-35V DC SELV = Safety Extra Low Voltage Power requirement < 3 W Warm up time 2) < 5 min EE80 96 Features / RH / T measurement in one device RH output with plug-in module analogue or switching output modern design optional display easiest installation long term stability v1.7
2 Display LC display: alternating (ppm) / T ( C or F) / RH (% RH) Electrical connection screw terminals max. 1.5 mm 2 (AWG16) Electromagnetic compatibility EN EN A1+A2: EN Working temperature range % RH (non condensing) / C ( F) Storage temperature range % RH (non condensing) / C ( F) 1) refer to the working range of the humidity sensor HC103! 2) warm up time for performance according specification Connection Diagram am EE80-xx2/3x EE80-xCS power supply V DC 24V AC ±20% power supply V DC 24V AC ±20% EE80-xx6x relay status switching off Hysteresis [% of MR] power supply V DC 24V AC ±20% ON 25% of MR OFF Level [% of MR] switching on Housing Dimensions (mm) ppm Material of housing: Protection class: PC IP20 Colour of housing: Cover: Back: RAL 9003 (signal white) RAL 7035 (light grey) (other colours upon request) W x H x D = 85 x 100 x 26mm (3.3 x 3.9 x 1 ) Ordering Guide EE80 voltage / current output: WORKING RANGE MODEL DISPLAY T-UNIT T-SCALE + T (CT) + T + RH (CTF) 0-5V (2) 0-10V (3) 4-20mA 1) (6) without display (--) with display (D04) C (--) F (E01) (T04) (T31) (T55) other (Txx) EE80- EE80-1) current output (6) not available for model CTF EE80 switching output: WORKING RANGE Accessories MODEL (C) switching output - humidity plug-in module (HA011003) (S) 97 Order Example EE80-2CT3D04-T04 Version with voltage output: Working range: ppm Model: + T Output: 0-10V Display: with display T-Unit: C T-Scale: C ( F) EE80
3 EE85 Series Duct mounted transmitters and switches of the EE85 series are designed for HVAC applications. The sensing element uses the Non-Dispersive Infrared Technology (NDIR). A patented auto-calibration procedure compensates for drift caused by the aging of the sensing element and guarantees outstanding long term stability. Installed into a duct a small flow of air will be established by convection through the probe into the transmitter housing and back into the duct. Inside the transmitter housing the air will diffuse through a membrane into the sensing element. The operation in closed loop air stream avoids pollution of the sensor. EE85 Measuring ranges of ppm and ppm correspond to an analogue interface of 0-5/10V or 4-20mA. Selectively a switching output with adjustable switching point and hysteresis is available. The instruments can be easily positioned in the duct with the standard mounting flange. Typical Applications building management for residental and office areas ventilation control Technical Data Measuring Values Measurement principle Sensing element Non-Dispersive Infrared Technology (NDIR) E+E Dual Source Infrared System Measuring range ppm / ppm Accuracy at 20 C (68 F) ppm: < ± (50ppm +2% of measuring value) and 1013mbar ppm: < ± (50ppm +3% of measuring value) Traceable to international standards, administrated by NIST, PTB, BEV... 1) Response time τ 63 < 120s Temperature dependence typ. 2ppm / C Long term stability typ. 20ppm / year Sample rate ca. 30s Outputs s ppm / ppm 0-5V -1mA < I L < 1mA 0-10V 4-20mA -1mA < I L < 1mA R L < 500 Ohm Max. switching voltage 50V AC / 60V DC Max. switching load 1A at 50V AC 1A at 24V DC Min. switching load 1mA at 5V DC Contact material Ag+Au clad General Supply voltage SELV 24V AC ±20% 15-35V DC SELV = Safety Extra Low Voltage Power requirement < 3W Warm up time 2) < 5 min Housing / protection class PC / housing: IP65, probe: IP20 Cable gland M16 x 1.5 cable Ø mm ( ) Electrical connection screw terminals max. 1.5 mm 2 (AWG 16) Electromagnetic compatibility EN ÖVE EN A1+A2: EN FCC Part 15 ICES-003 ClassB Working temperature and conditions C ( F) % RH (not condensating) Storage temperature and conditions C ( F) % RH (not condensating) 1) minimum flow speed 1m/s (200ft/min) 2) warm up time for performance according to specification EE Transmitter and Switches for Duct Mounting Features very simple installation compact housing auto-calibration traceable calibration measuring ranges: ppm or ppm analogue or switching output v1.3
4 Dimensions (mm) Operation Principle 12 (0.47 ) Seal 37.2 (1.46 ) sensing element A 80 (3.15 ) A...according to ordering guide 80 (3.15 ) air flow direction Connection Diagram am s EE85-xC2/3x EE85-xCSx EE85-xC6x relay status switching off Hysteresis [% of MR] ON 25% of MR ma OFF Level [% of MR] switching on ppm Ordering Guide Order Example MEASURING RANGE EE85- MODEL PROBE LENGTH (see dimensions A ) (C) 0-5V (2) 50mm (2) 0-10V (3) 200mm (5) 4-20mA (6) switching output (S) EE85-5C35 measuring range: ppm model: output: 0-10V probe length: 200mm 103 EE85
5 EE82 Series Measuring instruments in green houses or life stock barns are exposed to a very demanding environment: high humidity levels, pollutants like fertilizers, herbicides and high ammonia concentrations are just a few of the many hazards. The robust, functional housing of the EE82 with integrated special filter has been designed for such applications. The air diffuses through the filter into the instrument enclosure. Then the air diffuses further through a second membrane filter integrated in the measuring cell. The measurement is based on the non-dispersive infrared (NDIR) technology. The patented auto-calibration procedure compensates for aging of the infrared source and guarantees high reliability, long term stability and eliminates the need of periodical recalibration in the field. Measuring ranges of /5000/7000ppm correspond to an analogue interface of 0-5/10V or 4-20mA. Selectively a switching output with adjustable switching point and hysteresis is available. The very practical snap-in mounting flange and connector for the supply voltage and outputs allow quick and easy installation of the EE82 without ever opening the housing. Typical Applications green houses fruit and vegetable storage life stock barns Technical Data Measuring Values Measuring principle Non-Dispersive Infrared Technology (NDIR) Sensing element E+E Dual Source Infrared System Measuring range /5000/7000ppm Accuracy at 20 C (68 F) ppm < ± (50ppm +2% of measuring value) and 1013mbar ppm < ± (50ppm +3% of measuring value) 1) Response time τ ppm < ± (50ppm +5% of measuring value) < 120s Temperature dependence typ. 2ppm / C Long term stability typ. 20ppm / year Sample rate ca. 30s Output /5000/7000ppm 0-5 / 0-10V -1mA < I L < 1mA 4-20mA R L < 500 Ohm Max. switching voltage 50V AC / 60V DC Max. switching load 1A at 50V AC 1A at 30V DC Min. switching load 1mA at 5V DC Contact material Ag+Au clad General Supply voltage SELV 24V AC ±20% 15-35V DC SELV = Safety Extra Low Voltage Power requirement < 3W Warm up time < 5 min Housing / protection class PC / IP54 Electrical connection M12 plug Electromagnetic compatibility EN ÖVE EN A1+A2: EN FCC Part 15 ICES-003 ClassB Working temperature and conditions C ( F) % RH Storage temperature and conditions C ( F) % RH (not condensating) 1) minimum air velocity 1m/s (200ft/min) EE82 98 Transmitters and Switches for Agriculture Applications EE82 Features easy installation compact housing auto-calibration measuring range /5000/7000ppm analogue or switching output v1.3
6 80 (3.15 ) Dimensions (mm) 80 (3.15 ) 51 (2 ) snap in - mounting kit Connection Diagram am EE82-xC2/3/6 EE82-xCS 1) GND internally conected relay status switching off Hysteresis [% of MR] ON 25% of MR OFF Level [% of MR] switching on ppm Ordering Guide Order Example MEASURING RANGE ppm (7) MODEL (C) 0-5V (2) 0-10V (3) 4-20mA (6) switching output (S) EE82-5C3 Measuring range: ppm Model: Output: 0-10V EE82- EE82 99
sensor, which compensates for ageing effects, is highly insensitive to pollution and offers outstanding long term stability.
USER S GUIDE EE800 - HVAC Room Transmitter for CO 2, Temperature and Relative Humidity GENERAL EE800 combines CO 2, temperature (T) and relative humidity (RH) measurement in one device with modern design.
More informationEE35. Industrial Transmitter for Dew Point Measurement. Autocalibration. Installation. Alarm Output. Integrated power supply. Typical Applications
EE35 Industrial Transmitter for Dew Point Measurement Exact dew point monitoring is increasingly playing a more important role in many industrial applications, such as drying processes, air pressure pipelines,
More informationHLX31 Series. Multifunctional Industrial Transmitter for Humidity / Temperature / Dew Point / Absolute Humidity... Model A. Model B.
Series The precise and reliable measurement of humidity in industrial processes is gaining more and more importance. The multifunctional transmitters series offer the ideal solution. The result of many
More informationEE360. High-End Moisture in Oil Transmitter. Typical applications. Features EE360 EE360. (+34)
is dedicated for reliable monitoring of lubrication, hydraulic and insulation oils as well as diesel fuel. In addition to highly accurate measurement of water activity (a w ) and temperature (T), calculates
More informationEE310. High-End Humidity and Temperature Transmitter for Demanding Process Control. Typical applications. Features EE310 EE310
is optimized for reliable measurement in demanding industrial applications. In addition to highly accurate measurement of relative humidity (RH) and temperature (T), the transmitter also calculates parameters
More informationEE75 Series. High-Precision Air / Gas Velocity Transmitter for Industrial Applications. Model A. Model B. Model C. Typical Applications.
Series High-Precision Air / Gas Velocity Transmitter for Industrial Applications The series air velocity transmitters were developed to obtain accurate measuring results over a wide range of velocities
More informationEE310. High-End Humidity and Temperature Transmitter for Demanding Process Control. Typical applications. Features EE310 EE310
High-End Humidity and Temperature Transmitter for Demanding Process Control is optimized for reliable measurement in demanding industrial applications. In addition to highly accurate measurement of relative
More informationIn order to minimize the impact of rain, snow, ice and solar radiation on the measurement the EE33-M must be mounted inside a radiation shield.
Humidity and Temperature Transmitter for High-end Meteorological Applications E33-M is optimized for reliable measurement under demanding weather conditions. Besides accurate measurement of relative humidity
More informationEE32/33 Series. Humidity / Temperature Transmitter for High Humidity and Chemical Applications. Typical Applications. Features
EE32/33 Series Humidity / Temperature Transmitter for High Humidity and Chemical Applications The highly accurate EE32/33 series are designed for fast and reliable measurement of relative humidity / dew
More informationOutput signal active note. Output signal. temperature DC V, DC V DC V, DC V DC V
Duct Air Quality Sensor Duct air quality sensor for detection of CO₂ with 0 to10 V output. Optional integrated, humidity, VOC sensors and LCD display. Type Overview Type active CO₂ 22DC-11 22DC-110L 22DCK-11
More informationHLX75 Series. High-Precision Air / Gas Velocity Transmitter for Industrial Applications. Model A. Model B. Model C
Series High-Precision Air / Gas Velocity Transmitter for Industrial Applications The series air velocity transmitters were developed to obtain accurate measuring results over a wide range of velocities
More informationOutput signal. 22DTM-16 BACnet DC V, DC V. Electrical data Power supply DC V, ±10%, 0.3 W
Duct Sensor CO₂ / Humidity / Temperature For combined measurement of CO₂, relative humidity and temperature in the duct. Dual channel CO₂ technology. The measured values are output via BACnet. NEMA 4X
More informationCDD4 Duct Carbon Dioxide Transmitter
Drill or punch a 1-1/8 or 1-1/4 hole in the duct at the preferred location and insert the probe into the hole to mark the enclosure mounting holes. Remove the unit and drill the four mounting holes. Clean
More informationOutput Signal. 22DTM-16 BACnet DC V, DC V. Electrical data Power Supply DC V, ±10%, 0.3 W
Duct Sensor CO₂ / Humidity / Temperature Duct air quality sensor for combined detection of CO₂, relative humidity and temperature. Designed for control and monitoring applications. Type Overview Type Output
More informationEE671 - Miniature Air Flow Transmitter
USER s guide EE671 - Miniature Air Flow Transmitter GENERAL The EE671 air velocity transmitter operates on the hot-film anemometer principle and features an innovative, very robust E+E sensing element
More informationEE870 Modular CO 2 Transmitter
EE870 Modular CO 2 Transmitter Manual BA_EE870_e // v1.5 // Technische Änderungen vorbehalten E+E Elektronik Ges.m.b.H. doesn't accept warranty and liability claims neither upon this publication nor in
More informationDuct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature with calibration certificates
1 883 1883P01 1883P02 QFM4160 AQF4150 Symaro Duct Sensors for relative humidity and temperature with calibration certificates QFM41 Operating voltage AC 24 V / DC 1353 Signal output DC 010 V / 420 ma for
More informationEnvironmental Conditions C - remote sensing probe up to 120 C (248 F)
EE33 Humidity / Temperature Transmitter for High Humidity and Chemical Applications The highly accurate EE33 series are designed for fast and reliable measurement of relative humidity / dew point temperature
More informationTEMPERATURE - HUMIDITY ELEKTRONIK EE08
TEMPERATURE - HUMIDITY ELEKTRONIK EE08 SENSOR MEASURE SIGNAL OUTPUT ELECTRICAL SUPPLY MODEL IN EOL MANAGER Temperature 0...1 V 12...24 V EE8 / ROTRONIC Humidity 0...1 V 12 24 V EE8 / ROTRONIC APPLICATION
More informationEE210. Humidity and Temperature Transmitter for Demanding Climate Control. Applications. Features. 36 v2.5 / Modification rights reserved EE210
Humidity and Temperature Transmitter for Demanding Climate Control The transmitter by E+E Elektronik meets the highest requirements in demanding climate control applications. Besides the accurate measurement
More informationSchneider Electric s SCD series of duct mount sensors measure the levels of CO 2. , RH (if equipped) and temperature of air inside a duct.
1 Series Specifications Input age. 24 VAC ±20%, 20 to 36 VDC Class 2 Analog....4-20 /0-5 VDC/0-10 VDC (selectable) Sensor Current Draw... 20-36 VDC 40 avg., 105 max. 24 VAC 50 avg., 150 max. Operating
More informationTRANSMITTERS. HygroFlex & HygroClip-EX. Applications. Highlights
HygroFlex & HygroClip-EX HygroFlex series may be used together with the intrinsically safe HygroClip-EX probes. The relative humidity and temperature can be displayed and output as analog signals. Calculated
More informationEE160 - Humidity and Temperature Transmitter for HVAC Applications
USER S GUIDE EE160 - Humidity and Temperature Transmitter for HVAC Applications GENERAL The EE160 transmitter, available for wall or duct mounting, is designed for the measurement of humidity and temperature
More informationApplication. Types Available. Duct sensor for air quality, temperature and humidity (optional) Datasheet
LK+ CO2+VOC Duct sensor for air quality, temperature and humidity (optional) Datasheet Subject to technical alteration Issue date: 04.04.2018 A002 Application Duct air quality sensor for detection of CO2,
More informationPlease Read Instruction Carefully Before Installation! Figure 1: A/CO2-DUCT
Installation and Operation Instructions A/CO2-DUCT Series Please Read Instruction Carefully Before Installation! Figure 1: A/CO2-DUCT PRECAUTIONS REMOVE POWER BEFORE WIRING. NEVER CONNECT OR DISCONNECT
More informationTOXALERT MODEL AIR 2000
TOXALERT MODEL AIR 2000 NOTE: Toxalert s Model GVU-CO 2 Sensor is the same as the Air2000R. Microprocessor-based, Infrared Environmental CO 2 Sensor OPERATOR S MANUAL TOXALERT TM INTERNATIONAL INC. P.O.
More informationEE211. Humidity and Temperature Transmitter for Continuous High Humidity. Features. 42 v1.3 / Modification rights reserved EE211 EE211
Humidity and Temperature Transmitter for Continuous High Humidity The is dedicated for accurate and long term stable measurement under continuous high humidity (>85 % RH) and condensing conditions in demanding
More informationFILTER NAME CONSTRUCTION FEATURES APPLICATIONS ORDER CODE MEMBRANE Body: polycarbonate Filter: PTFE membrane
Filter Caps for Humidity and Dewpoint Transmitters with probe 12 mm (0.47 ) The right choice of appropriate filter cap is essential for best long term performance in the application. For assistance please
More informationProduct Specification. tsense VAV. CO 2 -, Temperature- and RH- sensor in a housing with colour touch display
Product Specification tsense VAV CO 2 -, Temperature- and RH- sensor in a housing with colour touch display General tsense VAV is an advanced and versatile 3-in-1 transmitter designed for installation
More informationImmersion Temperature Sensors
1 782 1782P01 Symaro Immersion Temperature Sensors QAE2164 QAE2174 Active sensors for acquiring the water temperature in pipes and tanks Operating voltage AC 24 V or DC 13535 V Signal output DC 010 V or
More informationInsertion Flowmeter for compressed air and gases DN50 - DN700 (2-28 )
The flow meter is based on the thermal mass flow measurement and is ideal for measuring the flow of compressed air and gases in pipes from DN50 (2 ) to DN700 (28 ). With the, the consumption of compressed
More informationRoom sensors QFA4160 QFA41 D AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates
1 859 1859P01 1859P02 1859P04 QFA4160 QFA41 D AQF4150 AQF3153 Symaro Room sensors for relative humidity and temperature with calibration certificates QFA41 Operating voltage AC 24 V / DC 13.5...3 Signal
More informationTEMPERATURE CO 2 CALIBRATION
HUMIDITY DEW POINT AIR VELOCITY 2009 / 2010 TEMPERATURE CO 2 CALIBRATION Our quality policy is the guide to all our business dealings The customer is our raison d'etre. Our motivation is the recognition
More informationCDR-RH Room CO 2, Temperature and Humidity Sensors (Controllers)
Product sheet SN1.401 Type CDR-RH CDR-RH Room CO 2, Temperature and Humidity Sensors (Controllers) CDR-RH sensors are designed to detect carbon dioxide concentration, relative humidity and temperature
More informationMulti-range pressure and differential pressure transmitter
Page 1/6 Multi-range pressure and differential pressure transmitter Type 402005 Applications Ventilation Air conditioning Clean-room technology Flue draft mechanisms Filter monitoring Brief description
More informationGMM220 CO 2. Transmitter Modules. Introduction. Mounting
Introduction GMM220 CO 2 Transmitter Modules Vaisala GMM220 transmitter modules are versatile instruments for measuring CO 2 in industrial applications. The CARBOCAP sensor is silicon based and its operation
More informationDSTHM-2 COMBINED T AND RH DUCT TRANSMITTER. Mounting and operating instructions
Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 4 OPERATIONAL DIAGRAMS 5 WIRING AND
More informationCDD4 Series Room CO2 Transmitter Installation Instructions
CDD4 Series Room CO2 Transmitter Installation Instructions Introduction The CO2 transmitter uses Infrared Technology to monitor CO2 levels and outputs a linear 4-20 ma or 0-5/0-10 Vdc signal. Options include
More informationManual EE371. Dew Point Transmitter / Switch down to -60 C Td. BA_EE371_e // V2.0 // technical data are subject to change
Manual EE371 Dew Point Transmitter / Switch down to -60 C Td BA_EE371_e // V2.0 // technical data are subject to change E+E Elektronik Ges.m.b.H. doesn't accept warranty and liability claims neither upon
More informationWIRELESS TRANSMITTER DUOS CO 2
WIRELESS TRANSMITTER DUOS CO 2 REF.: PA160411110 / PA160412410 Tekon Wireless Transmitter DUOS CO2 is an accurate solution for measurement and monitoring of CO2 for demanding applications. Taking advantage
More informationRoom unit with PPS2 interface
1 626 Room unit with PPS2 interface for use with: controllers with a PPS2 interface QAA88.3 Room temperature measurement Key buttons for adjustment of the room temperature setpoint Key buttons for operating
More informationHygroFlex HF3 Transmitters. User Guide
Page 1 of 27 HygroFlex HF3 Transmitters User Guide Page 2 of 27 Table of contents 1 Overview... 3 2 Mechanical configurations and dimensions... 4 2.1 Display option... 5 3 General description... 6 3.1
More informationUSER S GUIDE. EE210 - Humidity and Temperature Transmitter for demanding Climate Control Applications GENERAL
USER S GUIDE EE210 - Humidity and Temperature Transmitter for demanding Climate Control Applications GENERAL The EE210 transmitter, available for wall or duct mounting, is designed for the highly accurate
More informationRTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions
Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS PRODUCT DESCRIPTION ARTICLE CODES INTENDED AREA OF USE TECHNICAL DATA STANDARDS OPERATIONAL DIAGRAMS WIRING AND CONNECTIONS
More informationCDD Carbon Dioxide Transmitter
Introduction The OSA CO2 transmitter uses Infrared Technology to monitor CO2 levels within a range of 0 2000 ppm and outputs a linear 4-20 ma or 0-5/0-10 Vdc signal. The enclosure is designed to operate
More informationThe PM1000 series is a universal 4 digit LED plug-on display for transmitters with 4-20mA 2 wire output and fitted with DIN43650 connector.
PM1000 SERIES PLUG-ON DISPLAY BRIGHT LED DISPLAY INDICATION RANGE -999 TO +9999 FITS TO DIN 43650 CONNECTOR PLUG-ON TO ANY TRANSMITTER WITH 4-20MA OUTPUT EASY TO SCALE ON SITE ROBUST DESIGN SET POINT OPTION
More informationTHERMASGARD TM 65. Immersion screw-in duct temperature measuring transducer, calibratable, with multi-range switching and active output TECHNICAL DATA
Patented quality product (Immersion sensor patent no. DE 10 2012 017 500.0) Calibratable temperature measuring transducer THERMASGARD with eight switchable measuring ranges, continuous linear output, enclosure
More informationL Series Humidity/-temperature sensors for use in heating, ventilation and air conditioning Technical data Humidity
Galltec Mess- und Regeltechnik GmbH MELA Sensortechnik GmbH Boschstr. 4 Raasdorfer Str. 18 71145 Bondorf. Germany 07987 Mohlsdorf-Teichwolframsdorf. Germany Tel. +49 (0)7457-9453-0 Tel. +49(0)3661-62704-0
More informationEE771 Series. Flowmeter for compressed air and gases in Industrial Applications. EE771 Compact. EE771 remote probe
Series Flowmeter for compressed air and gases in Industrial Applications The flowmeter of the series, based on the measurement principle of thermal mass flow, is ideally suited for the measurement of flow
More informationaccurate measurement of compressed air consumption and leakage detection Calibration certificates and continous calibration, OEKD calibration service
Series Flowmeter for compressed air and gases in Industrial Applications The flowmeter of the series, based on the measurement principle of thermal mass flow, is ideally suited for the measurement of flow
More informationEE210. Humidity and Temperature Transmitter for Demanding Climate Control Applications. Features. Applications
EE210 Features Appropriate for US mounting requirements» Knockout for ½ conduit fi tting External mounting holes» Mounting with closed cover» Electronics protected against construction site pollution»
More informationInBin-P Pressure switches from 5 Pa Pa
InBin-P Pressure switches from 5 Pa...100 Pa Electrical, binary pressure or differential pressure switches with adjustable switch activation delay 24 VAC/DC supply voltage, potential free switching contact
More informationCAEL-DP Series Dew Point Transmitter for Industrial Control
CAEL-DP Series Dew Point Transmitter for Industrial Control SERIAL's latest CAEL series Dew Point transmitter meets the harsh environmental requirements for Dew Point measurement. Via temperature and relative
More informationExBin-D Transducers for ExPro-B... sensors (probes) ExPro-B... Thermostats / humidistats ( C, % rh)
Transducers for ExPro-B... sensors (probes) ExPro-B... Thermostats / humidistats ( C, % rh) Electrical, explosion proof transducers only connectable to ExPro-B... thermostats and humidistats 24 VAC/DC
More informationDXTH DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY. Mounting and operating instructions
DUAL DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL
More information2F. No.25, Industry E. 9 th Rd., Science-Based Industrial Park, Hsinchu, Taiwan
OGM220 Series Dual Channels NDIR CO 2 Gas Sensor Module Introduction OGM220 series is a dual channels NDIR module having a digital output directly proportional to CO 2 concentration. OGM220 is designed
More informationHMT330 Series Humidity and Temperature Transmitters for Industrial Applications
HMT330 Series Humidity and Temperature Transmitters for Industrial Applications The HMT330 transmitter family has the solution for demanding industrial humidity measurements. Six models for demanding industrial
More informationRТTH DUAL ROOM SWITCH
DUAL ROOM SWITCH FOR TEMPERATURE AND RELATIVE HUMIDITY Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS PRODUCT DESCRIPTION ARTICLE CODES INTENDED AREA OF USE TECHNICAL DATA
More informationInCos-P Pressure sensor 20 Pa Pa
InCos-P Pressure sensor 20 Pa... 7.500 Pa Electrical pressure / differential pressure sensors 24 VAC/DC supply voltage, 0...10 V / (0) analogue Compact. Easy installation. Universal. Cost effective. Safe.
More informationUSER S GUIDE. EE211 - Heatead Humidity and Temperature Transmitter for High Humidity Applications GENERAL ASSEMBLY SCOPE OF SUPPLY CAUTION
USER S GUIDE EE211 - Heatead Humidity and Temperature Transmitter for High Humidity Applications GENERAL The EE211 is dedicated for accurate, long term stable measurement under high humidity and condensing
More informationFlush-mount room sensor
s 1 410 AQR253 AQR254 Symaro Flush-mount room sensor AQR253 AQR254 Active flush-mounted room sensor comprising front module, base module and design frame accessory that can be ordered separately Operating
More informationDP DP2500 DP0250
DP7000 - DP2500 DP0250 PB_DP7000_DP2500 - DP0250_07 2016 Field adjustable, multi-range differential pressure transmitters Product Bulletin The Delta Pressure transmitter series of Johnson Controls, with
More informationPrecision digital measuring device PHYSICS 51
Precision digital measuring device PHYSICS 51 Digital measuring device for thermocouples, NTC resistance thermometers, infrared temperature probes, capacitive humidity probes. Technical data PHYSICS 51
More informationDMT PERFORMING UNDER PRESSURE DMT. Applications. Special features. Description 1/9
Applications Industry (laboratory, workshop and production) Transmitter and pressure gauge manufacturers Calibration service companies and service industry Research and development laboratories National
More informationHWS Series Wall Mount with Relay Setpoints, LCD, and Humidistat Control
Wall Mount with Relay Setpoints, LCD, and Humidistat Control NOTICE This product is not intended for life or safety applications. Do not install this product in hazardous or classified locations. Read
More informationAIR QUALITY/ GAS DETECTION
AIR QUALITY/ GAS DETECTION Veris offers an extensive line of CO, and NO 2 sensors. Whether your application requires ventilation of a parking garage or an indoor venue, we have the perfect product for
More informationEase of Use. Data at Your Fingertips LMS PHARMA
LMS PHARMA Ease of Use LMS Pharma was designed with an ICON driven user interface which greatly simplifies the user experience. Color coded status and unique shaped ICONS enhance the already intuitive
More informationHumidity goes Digital
Industrial Humidity Temperature Transmitter Dew-point and other calculated values Wide range of digital interchangeable probes No need for field calibration PC compatible and RS485 networkable SWISS MADE
More informationHygroFlex HF3 Transmitters and Thermohygrostats: User Guide
Page 1 of 26 HygroFlex HF3 Transmitters and thermo-hygrostats Page 2 of 26 Table of contents 1 Overview... 3 2 Mechanical configurations and dimensions... 4 2.1 Display option... 5 3 General description...
More informationFTM84/85 Feature Application. Temperature & Humidity / Flow Measuring Specialist
FTM84/85 Feature Application IP65 protection degree, rugged aluminum case, fit in variety harsh environment Capable of temperature compensation Llinear adjustment air velocity by computer, analogue output
More informationDP2500 DP0250. Differential Pressure Transmitter. Product Bulletin
DP2500 DP0250 Differential Pressure Transmitter Product Bulletin The DP Low Differential Pressure Transmitter series is an accurate and cost competitive solution for measuring low pressures of air and
More informationUser Guide. Indoor Air Quality Meter/Datalogger. Model EA80
User Guide Indoor Air Quality Meter/Datalogger Model EA80 Introduction Congratulations on your purchase of the Extech EA80 Indoor Air Quality Meter. This meter measures Carbon Dioxide (CO 2, ppm) levels,
More informationSensor for car parks and tunnels
Page 1 Sep. 2017 system with exchangeable sensor element including digital value processing, temperature compensation and selfmonitoring algorithm for the continuous sensing and control of the ambient
More informationAM3 Humidity. Temperature. Dew Point Indicator INSTRUCTION MANUAL
AM3 Humidity. Temperature. Dew Point Indicator INSTRUCTION MANUAL CONTENTS 1. Battery Operation... 3 2. Operation with a Rechargeable Battery... 3 3. Humidity and Temperature Probe (Probe Input 1)... 3
More informationPHYSICS Digital Measuring Devices
PHYSICS Digital Measuring Devices For precise measurements in meteorology, chemical, pharmaceutical and food industries, biotechnology, water analytics, science and research as well as industrial quality
More informationHT Series Wall Mount with Analog Setpoints, LCD, and Humidistat and Thermostat Control
Wall Mount with Analog Setpoints, LCD, and Humidistat and Thermostat Control NOTICE This product is not intended for life or safety applications. Do not install this product in hazardous or classified
More informationEvo2. Free programmable room controller. Summary
Evo2 Free programmable room controller Summary EVO2 is a free programmable room controller with Linux operating system. It contains an embedded room temperature sensor, relative humidity and CO 2 sensors
More informationQXA2000 QXA2001. Condensation Monitor QXA2001 QXA2000 AQX2000
1 542 1542P03 1542P01 1542P02 QXA2001 QXA2000 AQX2000 Condensation Monitor QXA2000 QXA2001 The QXA2000 condensation monitor is used to avoid damage due to condensation on chilled ceilings and in HVAC plant.
More informationHT Series Wall Mount with Relay Setpoints, LCD, and Humidistat and Thermostat Control
Wall Mount with Relay Setpoints, LCD, and Humidistat and Thermostat Control NOTICE This product is not intended for life or safety applications. Do not install this product in hazardous or classified locations.
More informationUser Manual. PolyGard AT Infrared Carbon Dioxide transmitter Serial No. AT December, PolyGard is a registered trademark of MSR
PolyGard AT82-1160 Infrared Carbon Dioxide transmitter Serial No. AT81-001 User Manual December, 2007 Page 2 1 Intended Use:... 3 2 Function... 3 3 Terminal Connections... 4 4 Calibration... 4 4.1 Calibration
More informationKCD-HP. KCD-HP200x, 300X. [Figures] Top : 1% Sensor probe Bottom left : 10% / 20% Sensor probe Bottom right : Holding bracket(optional) Measurement
Our CO2 gas sensors get a small deviation unlike NDIR Single type. So they keep long term stability. KCD-HP100x Excellent stability and accuracy - through testing and calibration with sophisticated process
More informationC7110C1001A / C7110D1009A WALL MODULES
HONEYWELL EXCEL 5000 OPEN SYSTEM GENERAL The C7110C1001A and C7110D1009A are combined CO2 / temperature wall modules designed for applications in indoor ventilation and air conditioning systems. In conjunction
More informationRoom unit with PPS2 interface
1 641 DESIGO RX Room unit with PPS2 interface for use with: QAX321 devices of the ranges DESIGO RXC, RXB, and RXA (PPS2) DESIGO PX Automation stations 1) devices with a PPS2 interface Room temperature
More informationTXM1.8RB. TX-I/O Blinds module
s 8 178 8178p01 TX-I/O Blinds module TXM1.8RB 8 non-floating relay outputs for... 4 blinds motors with 2 end switches, or 2 blinds motors with 3 end switches, or 2 blinds motors with 2 end switches + 1
More informationRoom Temperature Controllers
3 021 Room Temperature Controllers for two-pipe fan coil units RCC10 Output for on / off valve actuator Outputs for three-speed fan Control depending on the room or return air temperature (RCC10) Automatic
More informationON/OFF HUMIDIFIER CONTROL (ROOM 0R DUCT SENSOR) WITH OUTDOOR TEMPERATURE RESET OVERVIEW WALL CONTROLLER INSTALLATION (TCY-BH-T-U)
(ROOM 0R DUCT SENSOR) WITH OUTDOOR TEMPERATURE RESET TCY-BH-T-U Wall controller with sensor TDC-BH-T-U Duct controller with sensor SOA-Tn10 Outdoor temperature sensor (Optional) OVERVIEW For wall applications
More informationEE210. Humidity and Temperature Transmitter for Demanding Climate Control Applications. Features. Applications
EE210 Features Appropriate for US mounting requirements» Knockout for ½ conduit fi tting External mounting holes» Mounting with closed cover» Electronics protected against construction site pollution»
More informationMOD-RI Room Interface Modules with Modbus
Product sheet MOD3.00 Type MOD-RI MOD-RI Room Interface Modules with Modbus The MOD-RI are room interface modules designed to provide room control interface for the building management systems. The MOD-RI
More informationHygroClip M22 Series. 2-wire loop powered humidity temperature transmitters INSTRUCTION MANUAL
HygroClip M22 Series 2-wire loop powered humidity temperature transmitters INSTRUCTION MANUAL 20060329 CONTENTS Overview... 3 Operation... 5 Power supply... 5 HygroClip S digital probe... 5 Temperature
More informationPTU300 Combined Pressure, Humidity and Temperature Transmitter
PTU300 Combined Pressure, Humidity and Temperature Transmitter For Demanding Applications Features Barometric pressure, humidity, and temperature measurement in one transmitter RS-232C serial interface
More informationTPM 80. Dew Point Transmitter. Manual. BA_TPM80_e // V1.0 // technical data are subject to change
TPM 80 Dew Point Transmitter Manual BA_TPM80_e // V1.0 // technical data are subject to change Pro air doesn t accept warranty and liability claims neither upon this publication nor in case of improper
More informationPrecision humidity/temperature control/sensing
HIGH ACCURACY HUMIDITY/TEMPERATURE TRANSMITTER HAHT Series Precision humidity/temperature control/sensing FEATURES: Highly stable RH sensor element Humidity range: 0-100% Accuracy available 1% & 2% High
More informationHygroFlex HF7 Humidity Temperature Transmitters. User Guide
Page 1 of 22 HygroFlex HF7 Humidity Temperature Transmitters User Guide Page 2 of 22 Table of contents 1 Overview... 3 2 Mechanical configurations and dimensions... 4 3 General description... 5 3.1 Power
More informationResistance measuring module
s 8 176 8176P01 TX-I/O Resistance measuring module TXM1.8P 8 inputs with LED signal / fault display. 8 resistance measuring inputs with individual configuration of resistance or temperature measurement.
More informationHTZ. Description. Features. Smart HART Humidity and Temperature Transmitter
March 2018 Description The HTZ Smart HART Transmitter simultaneously measures humidity and temperature in industrial, commercial, manufacturing, and HVAC applications. Based on the humidity and temperature
More informationDifferential pressure sensor For ventilation and air-conditioning Model A2G-50
Electronic pressure measurement Differential pressure sensor For ventilation and air-conditioning Model A2G-50 WIKA data sheet PE 88.02 for further approvals see page 5 Applications For measuring differential
More informationRoom Temperature Controller
3 023 Room Temperature Controller for four-pipe fan coil units RCC30 Outputs for on / off valve actuators Outputs for three-speed fan Control depending on room or return air temperature Operating modes:
More informationTable of contents: 1. HygroClip 2 in general. 2. The different probes. 3. Features in details. 4. Customer benefits. 5. Replacement overview
HygroClip 2 Table of contents: 1. HygroClip 2 in general 2. The different probes 3. Features in details 4. Customer benefits 5. Replacement overview 1. HygroClip 2 in general The HC2-series are digital
More informationProduct Specification. CO 2 Engine ICB. Sensor module for bio applications
Product Specification CO 2 Engine ICB Sensor module for bio applications General CO 2 Engine ICB is targeted on bio applications with required measurement range 0 to up to 30% vol CO 2. This document contains
More informationRXTH DUAL ROOM SENSOR / SWITCH
DUAL ROOM SENSOR / SWITCH FOR TEMPERATURE AND RELATIVE HUMIDITY Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE
More information