Bulletin 1492-MC 1492-MCGA, -MCEA 1492-SP
|
|
- Theodore Dean
- 6 years ago
- Views:
Transcription
1 Bulletin Control Circuit and Load Protection Product Overview Bulletin -MC -MCGA, -MCEA -SP Type Branch Ground Fault Detection Features /V, V & Y/V rating A interrupt / in. per pole wide... UL Circuit breaker with ground /V AC &... V AC fault circuit interrupter and ground IPX finger-safe, built-in with / in. fault equipment protector wide, add protectors for in. wide Mounts on DIN Rail or panel mount Ratings to Y/V AC, A interrupt ratings Mounts on DIN Rail Number of Poles -, -, -pole - and -pole with Neutral Maximum Voltage Tripping Characteristic Reference Temperature /V AC V AC /V AC Hz Miniature Supplementary Protector True IPX finger-safe design (front) Field mountable options for selective applications AC and DC voltage ratings in one convenient device Superior shock and vibration resistance capabilities Mounts on DIN Rail -, -, -pole -pole + neutral, -pole + neutral Y/V AC -pole V DC -pole V DC F ( C) F ( C) F ( C) Tripping Characteristic UL Standard (CSA. No..) UL/CSA Standard Certifications UL Listed (CSA. No..) UL File Number E UL, and CSA. No.. B Curve... In C Curve... In D Cruve... In UL CSA. No. VDE (IEC ) GL ( -) Dielectric Strength V AC V AC V AC Shock G half sine wave for ms ( axes) Vibration... Hz for hour... Hz for hour... Hz for hour Wire Size #.../ AWG #... AWG C (Cu only) #... AWG (... mm) Electromechanical Life UL specifications UL specifications operations Interrupt Rating V AC /V AC IEC V AC IEC - V AC UL/CSA ka U Operating Temperature (non-condensing)... F ( + C)... F ( + C) F (- + C) Product Selection Page - Page - Page - Publication A-CAA-EN-P -
2 Bulletin -MC Product Overview/Description Bulletin -MC s Industrial s for North American Applications The Bulletin -MC line includes: / in. wide circuit breakers in. wide circuit breakers Ground Fault Circuit Interrupters (GFCIs) Ground Fault Equipment Protector (GFEPs) Features Designed, manufactured and listed to UL (CSA C., No. ) Thermal-magnetic protection All Ratings ( A) are HACR rated kaic ( A) Finger-safe design (front) (/ in. wide) DIN Rail mounting (/ & V AC) Three-position handle (ON, Tripped (Middle), OFF) (Line and load) wire connections Table of Contents AC DIN Rail Mounting... - Specifications... - Product Selection... - Approximate Dimensions... - Certifications UL Listed CSA Certified Standards Compliance for Bul. -MC UL CSA C. No. HACR (... A) SWD ( and A) for Switching Duty for flourescent lighting applications Standards Compliance for GFCI ( ma trip sensitivity) UL CSA C. No. Bulletin -MC Thermal Magnetic Description Thermal Magnetic s Bulletin -MC s for Branch Circuit protection are available in one ()-, two ()-, and three ()-pole construction in / volt rating, volt rating and as one ()-pole and two ()- pole devices in / volt rating. Versions are available as Ground Fault Circuit Interrupters and as Ground Fault Equipment Protectors. The -MC product line consists of Thermal Magnetic Circuit Breakers and Ground Fault Sensing Breakers that are designed, manufactured, and certified to North American standards, UL, UL, UL, and the equivalent CSA standards, CSA. No..,. No.. Bul. -MC Thermal Magnetic s are generalpurpose devices suitable for the majority of industrial, inverse time circuit breaker applications. They combine thermal and magnetic trip actions and provide accurate overload and short-circuit protection for conductors and connected equipment. Application Information Selection of a Bul. -MC circuit breaker with appropriate circuit protection includes consideration of: Circuit voltage Circuit frequency Available short circuit current Continuous current rating Application considerations Special operating conditions The following discussion is based upon National Electric Code and UL requirements. Similar considerations are appropriate for Canadian applications. Circuit Voltage Bul. -MC circuit breakers are rated by voltage class. Applications should not exceed the listed voltage range (see Table ). Standards Compliance for GFEP ( ma trip sensitivity) UL CSA C. No. Circuit Frequency Bul. -MC circuit breakers may be applied to frequencies from DC up to Hz without derating. For applications above Hz, contact Rockwell Automation with specific application information for the derating of the circuit breakers. Available Short Circuit Current Bul. -MC circuit breakers should only be applied in those applications in which the available short-circuit (or fault) current is less than or equal to the interrupting rating shown in the Voltage and Interrupting Ratings table. Table. Voltage and Interrupting Ratings Interrupting Ratings (rms Symmetrical Amperes) AC Voltage DC Voltage AC Rating DC Rating Cat. No. /,,., -MCAAxx -MCAAxx -MCAAHxx,,., -MCAAxx, -MCBAxx / -MCBAxx -MCBAHxx -MCBAxx -MCEAxx / -MCEAxx, -MCGAxx / -MCGAxx Rating as supplementary protector. Consult your local Rockwell Automation sales office or Allen-Bradley distributor for specific rating. - Publication A-CAA-EN-P
3 Continuous Current Rating Bul. -MC circuit breakers are rated in RMS amperes at a C ( F) ambient temperature per UL (CSA. No..). This temperature is generally used as the average temperature within an industrial enclosure. If a circuit breaker is applied in a temperature that exceeds the C ( F) ambient, then the circuit breaker should be derated. Contact your local Rockwell Automation sales office or Allen-Bradley distributor for derating information. The characteristic trip curves are shown on pages - -. The trip bands shown for each breaker represent current tripping limits for a circuit breaker and are within the limits established by UL. For a specific current at C ( F), a circuit breaker will open ("clear the circuit") automatically at some total time that will be within the "Minimum" and "Maximum" time shown as the "Minimum" and "Maximum" curves. For example, page - shows that a one pole, A, -MC trips in not less than s and not more than s on a A current. Because the UL standard defines this time spread, users should not specify exact tripping time. The lower current portion of the curves (upper left) depict the time to trip due to thermal action and reflect overload protection of the wire and connect load. The higher current portion of the curves (lower right) depicts the trip due to magnetic action of the circuit breaker and reflects protection due to short circuit level currents. Standard current ratings are,,,,,,,,,,,,,,, and A. Application Considerations The selection of a specific ampere rating for a specific application is dependent on the type of load and duty cycle and is governed by the National Electric Code (Canadian Electric Code) and UL/CSA. In general the codes require that overcurrent protection is at the current supply and at points where wire sizes are reduced. In addition the codes state that conductors be protected according to their current carrying capacity. There are specific situations that require application consideration, such as motor circuit, and guidelines for the selection for transformer protection. Bulletin -MC circuit breakders are "non-% rated" as defined by UL Part... As such the circuit breaker's rating should be loaded to no more than %, if used with continuous loads. Bulletin -MC Product Description Branch Circuits: Bulletin -MC circuit breakers may be used to protect branch circuits. A branch circuit is the wiring portion of a system extending beyond the final overcurrent device protecting the circuit. Guidelines established in NEC, CEC, UL, and CSA should be used to determine the specific device. For example: ) Motor Branch Circuit Bulletin -MC circuit breakers are not horsepower rated because they are able to safely interrupt currents far in excess of the locked rotor value for a selected motor. This ability is recognized in the codes and standards and is also established by the UL and CSA tests described in UL and CSA C. No.. standards. The size of a Bulletin -MC circuit breaker should be determined following the guidelines for an Inverse Time. References: NEC. and UL A. Also see CEC and appropriate Canadian Standards. ) Transformer Protection Bulletin -MC circuit breakers may be used for transformer protection following the guidelines established. References: NEC and UL A. Also see CEC and appropriate Canadian Standards. ) Heater Load, Lighting, and Other Load Protection Bulletin -MC circuit breakers may be used for protection of heater loads, lighting loads, and other loads following the guidelines established. References: NEC Article and UL A. Also see CEC and appropriate Canadian Standards. Coordinated Overcurrent Protection Where an orderly shutdown is required to minimize the hazards to personnel and equipment, a system of coordination based upon the faulted or overloaded circuit is isolated by selective operation of only the overcurrent protective device closest to the overcurrent condition. The user should select devices that meet this requirement. References: NEC.. Also see CEC. Publication A-CAA-EN-P -
4 Bulletin -MC Product Description Time Current Curve -Pole Time Current Curve -MCAANN -MCEANN -MCBANN -MCGANN -pole MINUTE HOUR HOURS,,,,, (- Amp) (- Amp) Maximum Single-Pole Trip Times at C➀,,,, ºC Ambient ft º/ ºC Wire per Terminal Open Air,,,,,,,,,,, HOURS HOUR MINUTE Minimum Maximum Maximum Interrupting Time ,,,,,,,,,,. - Publication A-CAA-EN-P
5 Bulletin -MC Product Description Time Current Curve -Pole s Time Current Curve -MCAANN -MCAAHNN -MCEANN -MCBANN -MCBAHNN -MCGANN -pole s MINUTE HOUR HOURS,,,,,,,,,,,,,,, ºC Ambient ft º/ºC Wire per Terminal Open Air Current in All Poles,,,,, HOURS HOUR MINUTE Minimum Maximum Maximum Interrupting Time ,,,,,,,,,,. Publication A-CAA-EN-P -
6 Bulletin -MC Product Description Time Current Curve -Pole s MINUTE HOUR HOURS,,,,, Time Current Curve -MCAANN -MCBANN -pole s,,,,,,,,,, ºC Ambient ft º/ºC Wire per Terminal Open Air Current in All Phases,,,,, HOURS HOUR MINUTE Minimum Maximum Maximum Interuppting Time ,,,,,,,,,, - Publication A-CAA-EN-P
7 Bulletin -MC Cat. No. Explanation/Product Selection -MC Cat. No. Explanation Examples given in this section are for reference purposes. This basic explanation should not be used for product selection; not all combinations will produce a valid catalog number. Code A B E G Code A a Body Style Description / in. wide/pole (DIN Rail mounting) in. wide/pole (DIN Rail mounting) GFEP ( ma) GFCI ( ma) b Interrupt Rating Description ka AIC Bul. -MC Thermal Magnetic Product Selection / and V AC DIN Rail Mounting -MC A A a b c d c Poles Code Description pole poles H poles (V AC) poles Current Rating Size Code Description Code Description A A A A A A A A A A A A A A A A / and V AC DIN Rail Mounting Cat. No. Cat. No. Width Width Continuous Ampere per pole /V AC per pole V AC C ( F) [in.] -pole -poles [in.] -poles -poles / -MCAA -MCAA / -MCAA -MCAA / -MCAAH -MCAA / -MCAA -MCAA / -MCAAH -MCAA / -MCAA -MCAA / -MCAAH -MCAA / -MCAA -MCAA / -MCAAH -MCAA / -MCAA -MCAA -MCBAH -MCBA / -MCAA -MCAA -MCBAH -MCBA / -MCAA -MCAA -MCBAH -MCBA / -MCAA -MCAA -MCBAH -MCBA / -MCAA -MCAA -MCBAH -MCBA / -MCAA -MCAA -MCBAH -MCBA -MCBA -MCBA -MCBAH -MCBA -MCBA -MCBA -MCBAH -MCBA -MCBA -MCBA -MCBAH -MCBA -MCBAA -MCBAA -MCBAHA -MCBAA -MC Ground Fault Sensing The Bulletin -MC s with Ground Fault protection for Branch Circuits are available in - and -pole construction in /V rating. Versions are available as Ground Fault Circuit Interrupters and as Ground Fault Equipment Protectors. When protection from low-level fault currents for North American standards is required, two versions of protection are available. s with protection for personnel use a threshold of ma sensing to provide protection for people. These are typically know as Ground Fault Circuit Interrupters or GFCIs. s that provide protection for equipment at a sensing threshold of ma are also available. These are typically known as Ground Fault Equipment Protectors or GFEPs. The following devices are tested and listed to meet the North American standards of UL, UL (for GFCI), UL (for GFEP), and CSA. No... It is recommended that the devices be tested monthly by using the TEST button to check for proper operation of the device. Auxiliary Devices Device description -pole - and -poles -MCAAxxx -AMCAL Locking Attachment for -AMCALM -MCBAxxx -AMCBL Finger protection cover for in. wide Cat. No. -MCBxxx, package of (one required -AMCBFP for line and one required for load for each pole) (not for GFCI / GFEP) DIN Rail adapter, per pole, DIN Rail mounting for GFCI, GFEP -AMCDIN Panel Mounting Clips for GFCI and GFEP, two required per device -AMCP d Publication A-CAA-EN-P -
8 Bulletin -MC Product Selection/Specifications Bul. -MC Ground Sensing Product Selection Specifications Terminals Cat. No. -MCAAxxx -MCBAxxx Standards Compliance UL, CSA C. No. Certifications Rated Voltage Continuous Current C ( F) Rated short circuit capability Degree of protection Mounting Operating Temperature Shipment and short term storage limits Wire Size Terminal Torque Recommended Wire Strip Length UL Listed, CSA Certified /V AC, V AC,,,,,,,,,,,,, Amp ka /V AC and V AC ka Y/V AC Open Device / in. wide circuit breakers are finger safe from front per IEC. Terminal Covers available for in. wide circuit breaker at / and V AC. DIN Rail (check product for specific) C (... F) (non-condensing) - C + C (-... F) See Terminals Table Below Cat. No. Cat. No. Continuous Ampere C ( F) [A] V AC /V AC GFCI ( ma Sensitivity) -pole -pole -MCGA -MCGA -MCGA -MCGA -MCGA -MCGA -MCGA -MCGA -MCGA -MCGA -MCGA GFEP ( ma Sensitivity) -MCEA -MCEA -MCEA -MCEA -MCEA -MCEA -MCEA -MCEA -MCEA -MCEA -MCEA For panel mounting use two -AMCP per device For DIN Rail mounting use one -AMCDIN per pole Continuous Current Rating Wire Type Wire Range [AWG] Terminal Torque Line Strip Length Line and Load Terminals A A A / lb in (. N m) lb in (. N m) lb in (. N m) lb in (. N m) lb in (. N m) lb in (. N m) / in. / in. Allen Head Copper (Cu) lb in (. N m) / in. Line -MCEAxxx A lb in (. N m) Load -MCGAxxx lb in (. N m) - Publication A-CAA-EN-P
9 Bulletin -MC Approximate Dimensions -MC Approximate Dimensions Note: Dimensions are shown in inches (millimeters). Dimensions are not intended for manufacturing purposes. Catalog Type No. of Poles Continuous Current Rating [A] Width [in.] -MCAAxx. -MCAAxx. -MCAAHxx. -MCAAxx. -MCBAxx.... -MCBAxx.... -MCBAHxx.... -MCBAxx.... -MCEAxx.... -MCEAxx.... -MCGAxx.... -MCGAxx.... -MCAAnxx. (.). (.) -MCEAxx -MCGAxx Line End View. (.). (.). (.). (.). (.). (.). (.). (.). (.) Width. (.) On. (.). (.) Radius Off Reset. (.) Trip. (.). (.) Terminal #-. (.). (.). (.). (.). (.). (.) DIN Rail Mounting Location. (.). (.). (.) Front View. (.). (.). (.). (.) Radius. (.) On Off Reset. (.). (.). (.) Trip. (.). (.). (.) Side View. (.). (.). (.). (.). (.). (.). (.). (.) Ground Neutral Wire Length. inches (.) Publication A-CAA-EN-P -
10 Bulletin -MC Approximate Dimensions -MCEAxx -MCGAxx Line End View. (.) Front View. (.). (.). (.). (.). (.). (.). (.). (.). (.). (.) A thru A style Radius. (.) On Off Reset. (.). (.) Trip Side View. (.). (.). (.). (.). (.) Bottom View. (.). (.). (.) Ground Neutral Wire Length. inches (.) -MCBAxxx. (.). (.). (.). (.). (.). (.) - Publication A-CAA-EN-P
Bulletin 1489 Circuit Breakers. Selection Guide
Bulletin 1489 s Selection Guide Overview/Description Bulletin 1489-A s Energy-limiting design protects downstream components better than conventional breakers during short circuits Field-mountable options
More informationMini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protectors Specifications Bulletin Number 1492, 1692
Technical Data Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protectors Specifications Bulletin Number 1492, 1692 Topic Page 1489-M Miniature Circuit Breakers 1 1492-SP Supplementary Protectors
More information1492-SP Supplementary Protectors
Dual terminals provide wiring/bus bar flexibility and clamp from both sides to improve connection reliability Approval marks are easily visible on dome Terminal design helps prevent wiring misses Scratch-
More informationSelection Guide. Control Circuit and Load Protection. Allen-Bradley 1489-M2C020
Selection Guide Control Circuit and Load Protection Circuit Protection Portfolio 1489-M Circuit Breakers Approved for branch circuit protection in the United States and Canada, and certified as Miniature
More informationControl Circuit and Load Protection Products
Selection Guide Control Circuit and Load Protection Products Bulletin Numbers 188, 1489, 1492, 1692 Circuit Protection Portfolio 1489-M Circuit Breakers Approved for branch circuit protection in the United
More informationSelection Guide. Control Circuit and Load Protection
Selection Guide Control Circuit and Load Protection Circuit Protection Portfolio 1489-M Circuit Breakers Approved for branch circuit protection in the United States and Canada, and certified as Miniature
More informationSelection Guide. Control Circuit and Load Protection
Selection Guide Control Circuit and Load Protection Circuit Protection Portfolio 1489-M Circuit Breakers Approved for branch circuit protection in the United States and Canada, and certified as Miniature
More informationApplying branch circuit breakers and supplementary protectors in North America
Product Application AP01102005E WMZT WMZS Applying branch circuit breakers and supplementary protectors in North America Introduction Eaton offers two types of miniature circuit breakers for use in North
More informationMiniature Circuit Breakers and Supplementary Protectors. Contents
. Optimum and Efficient Protection for Every Application Product Overview Features Optimum product quality, tested reliability and safety stand for best protection of personnel, installations and plant.
More informationAllen-Bradley 1492-RCDA4A40
Dual terminals provide wiring/bus bar flexibility and clamp from both sides to improve connection reliability Suitable for DIN Rail mounting Approval marks are easily visible on dome Terminal design helps
More informationApplying branch circuit breakers and supplementary protectors in North America
Supersedes June 2017 FAZ-NA-L FAZ-NA FAZ Applying branch circuit breakers and supplementary protectors in North America Introduction Eaton offers three types of miniature circuit breakers for use in North
More informationTeSys IEC Contactors and Overload Relays
TeSys IEC Contactors and Overload Relays Making High-Fault Short-Circuit Current Ratings Simple Schneider Electric is an industry leader in IEC contactors and overload relays, and is recognized as the
More information1.3. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZS Circuit Breaker. UL 1077 DIN Rail Supplementary Protectors
. Miniature Circuit Breakers and Supplementary Protectors UL 077 DIN Rail Supplementary Protectors WMZS Circuit Breakers Contents Description WMZS Circuit Breaker Standards and Certifications................
More informationUL 489 DIN rail branch circuit breakers
UL 9 DI rail branch circuit breakers FAZ-A circuit breakers Product Overview UL 9 DI rail branch circuit breakers FAZ-A circuit breakers PRODUCT OVERVIEW Optimum and efficient protection Optimum product
More informationUL 489 DIN Rail Miniature Circuit Breakers
UL 489 DIN Rail Miniature Circuit Breakers Product Overview................................................ 2 Product Selection................................................ 4 Accessories.....................................................
More informationUL 489 DIN Rail Miniature Circuit Breakers
UL 9 DIN Rail Miniature Circuit Breakers Product Overview................................................ Product Selection................................................ Accessories.....................................................
More informationWMS SUPPLEMENTARY PROTECTORS
WMS Supplementary Protectors Overview WMS SUPPLEMENTARY PROTECTORS Product Specification The WMS Supplementary Protector is a dual-rated product for both AC and DC supplies, in accordance with UL 1077
More informationFAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview
FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview Supplementary Protectors / Miniature Circuit Breakers Page System overview 10/003 10/001 Supplementary protectors
More informationIssued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog
Issued February 2011 DATA SHEET 5SX2 MCB Based on Siemens Industrial Control Catalog General Data Trip characteristics Tripping characteristics acc. to EN 60 898 Tripping characteristic A, -5 Type A characteristic
More informationClose Protection from Moeller. miniature branch circuit breakers miniature supplementary protectors
Close Protection from Moeller miniature branch circuit breakers miniature supplementary protectors FAZ branch circuit breakers General Information... Selection Tables Trip Characteristic C - Box terminals...
More informationMG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD
United States MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD Product Information Features and Specifications For Use With: OEM Panels Approvals: UL
More information9926 Series Branch Rated Circuit Breakers AC Version
Branch Rated AC Version Hydraulic Magnetic Single pole and double pole versions 20/240 VAC, 50/60 Hz Up to 25A Just 3 mm wide Mounts on 35mm DIN-rail UL 489 listed, CSA C22.2 No. 5-02, CE VDE Ordering
More informationUL 489 Cable-In / Cable-Out Branch Circuit Breaker
Product Overview UL 9 Cable-In / Cable-Out Branch Circuit Breaker PRODUCT OVERVIEW Optimum and Efficient Protection Features Complete range of UL 9 listed DIN rail mounted miniature circuit breakers up
More information24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD
United States 24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Approvals: IEC 60947-2 Rated
More information60103 Circuit Breaker
6003 Circuit Breaker United States MINIATURE CIRCUIT BREAKER, 20/240VAC, 2A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Circuit Breaker Type: Standard
More informationMULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors
B Curve NC100H Supplementary Protectors Rating 1P 2P 3P 4P 80 MG27164 MG27175 MG27186 MG27197 MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors C Curve NC100H Supplementary Protectors
More informationSection 4 Ground-Fault Protection Devices
Multi 9 System Catalog Section 4Ground-Fault Protection Devices Section 4Ground-Fault Protection Devices Selection Table The Multi 9 System includes one UL Listed and three IEC rated product families that
More information1.2. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZ Circuit Breaker. UL 489 DIN Rail Miniature Circuit Breakers
.2 WMZ Circuit Breakers Contents Description WMZ Circuit Breaker Standards and Certifications.............. Selection................ Product Selection....................... Accessories...........................
More informationMULTI 9 System Catalog UL Recognized C60N Supplementary Protectors
UL Recognized C60N Supplementary Protectors B Curve C60N Supplementary Protectors 1 MG24110 MG24125 MG24140 MG24155 15 MG17406 MG17436 MG17461 1.2 MG17402 MG17432 16 MG24118 MG24133 MG24148 MG24163 1.5
More informationCircuit Protection Methods
Circuit Protection Methods Differentiating between Supplementary Protection, Branch Circuit Protection, and Self-Protected Devices Introduction Modern electrical equipment continues to increase in complexity
More informationProduct Guide. UL 1077 DIN Rail Supplementary Protectors
Product Guide UL 0 DIN Rail Supplementary Protectors UL 0 DIN Rail Supplementary Protectors Product Overview... Product Selection WMZS B Curve ( X I n Current Rating)..............................................
More informationIntroduction Circuit Protection
Introduction Circuit Protection Weidmuller s DIN-rail mounted circuit breakers are available for use in applications where circuit protection must be able to distinguish between circuit overloads and short
More informationIELR Rail-Mount Series Magnetic Circuit Protectors
IELR Rail-Mount IELR Rail-Mount Series Magnetic Circuit Protectors Introduction 92 Single Pole 93 Specifications 94 Operating Characteristics 95 Delay Curves 96 Approvals & Decision Tables 200 IELR Series
More information209/219/229 Multi-Pole Circuit Protectors 202 branch circuit applications such as EDP, air conditioners, panel boards
The 29, E-Frame circuit breaker combines power switching with accurate, reliable circuit protection 29/29/229 Magnetic Circuit Protectors 99 in a compact single or multipole 249 Power Selector Breaker
More informationIELR Series
IELR Series Rail-Mount Magnetic Circuit Protectors Introduction Poles Specifications Operating Characteristics Delay Curves Approvals Decision Tables 6 62 63 64 65 69 70 IELR Series Rail-Mount Hydraulic
More informationProduct Guide. UL 489 DIN rail miniature circuit breakers
Product Guide UL 489 DIN rail miniature circuit breakers UL 489 DIN rail miniature circuit breakers Product Overview................................................ 2 Product Selection WMZT 10 kaic at
More informationComplete UL/CSA Disconnect Switch Kits
Product Selection Complete UL/CSA Disconnect Switch Kits Includes disconnect switch, operating handle with defeater mechanism and operating shaft, NFPA handle, auxiliary contacts, and padlock attachment.
More informationDIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS. Introducing the DIN Series High-quality, high-performance circuit breakers
DIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS Introducing the DIN Series High-quality, high-performance circuit breakers Features (1) All models fully comply with IEC regulations
More informationMULTI 9 System Catalog
MULTI 9 System Catalog Class 80 CONTENTS Page Schneider Electric Brands Section Introduction... Section UL Rated Protection Devices... Section IEC 097- Rated Protection Devices... Section IEC Rated Ground-fault
More informationIhr autorisierter Distributor: Neumüller Elektronik GmbH
IELR Series Rail-Mount Magnetic Circuit Protectors Introduction Poles Specifications Operating Characteristics Delay Curves Approvals Decision Tables 6 62 63 64 65 69 70 Neumüller Elektronik GmbH Gewerbegebiet
More informationLearning Module 9: Miniature Circuit Breakers and Supplementary Protectors. 101 Basic Series
Learning Module 9: Miniature Circuit Breakers and Supplementary Protectors 101 Basic Series What You Will Learn We ll step through each of these topics in detail: Introduction 4 Miniature Circuit Breakers
More informationApplication Switchgear for industrial and advanced commercial applications. U e V AC 277/480 Y V DC 60
DATASHEET - FAZ-C5/2-RT Miniature circuit breaker (MCB), 5A, 2p, C-Char, AC Part no. FAZ-C5/2-RT Catalog No. 102203 Eaton Catalog No. FAZ-C5/2-RT EL-Nummer 1691799 (Norway) Similar to illustration Delivery
More informationMagnetic Circuit Protectors 153. Multi-Pole Circuit Protectors 154. APL/UPL, 205/295 Barriers 155. Configurations 156. Operating Characteristics 158
Magnetic Circuit Protectors 53 Multi-Pole Circuit Protectors 54 APL/UPL, 205/295 Barriers 55 Configurations 56 Operating Characteristics 58 Delay Curves 59 Specifications 64 APL/UPL Decision Tables 70
More informationDeltaV Bulk Power Supplies
DeltaV Distributed Control System Product Data Sheet DeltaV Bulk Power Supplies DeltaV 5 A, 10A, 20 A, 40 A Bulk Power Supplies. DeltaV 20 A, 40 A and 80 A Bulk Power Supply Redundancy Modules. Easy to
More informationZelio Control-modular measurement and control relays 1
Presentation, description 1 106439 RM35 TM111MW Presentation Motor temperature measurement and 50MW and RM35 TM250MW monitor the following, on 3-phase supplies: correct sequencing of phases L1, L2 and
More informationBulletin 817 Thermistor Protection Relay
6 Bulletin 817 Accurate Temperature Monitoring for Critical Applications Automatic, Manual and Remote Reset Status Indicating LEDs DIN Rail or Panel Mounting Guarded Terminals IP20 1 N.O. and 1 N.C. Output
More informationBulletin 290/291 ArmorStart LT Distributed Motor Controllers Specifications
Power Circuit Control Circuit (External Source) Control Circuit (Internal Source) Short Circuit Current Rating (SCCR) Application Electrical Ratings Three-phase Number of Poles 3 Input Power Terminals
More informationApplication Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole) I cs 7,5 ka
DATASHEET - FAZ-C16/1 Miniature circuit breaker (MCB), 16A, 1p, C-Char, AC Part no. FAZ-C16/1 Catalog No. 278561 Eaton Catalog No. FAZ-C16/1 EL-Nummer 0001695154 (Norway) Similar to illustration Delivery
More informationAPL/UPL, 205/295 Series Magnetic Circuit Protectors
APL/UPL, 205/295 APL/UPL, 205/295 Series Magnetic Circuit Protectors Introduction 68 Single & Multi-Pole 69 Barriers 7 Configurations 72 Operating Characteristics 74 Delay Curves 75 Specifications 80 Decision
More informationContacts Contact Arrangement. 8-Pole Relay. 12-Pole Relay
Bulletin -P Heavy-Duty Industrial s Product Selection DC-Operated s Rail Mount DIN Rail Mount Cat. No. Cat. No. -Pole DC-P DC-PD DC-P DC-PD -Pole DC-P DC-PD DC-P DC-PD -Pole DC-P DC-PD DC-P DC-PD DC Coil
More informationALLEN BRADLEY RELAY Bulletin 700-HF
ALLEN BRADLEY RELAY Bulletin 700-HF Contact Rating DPDT, 3PDT, 4PDT Plug-in Quick Connect Solder Terminals Options: LED, Push-to-Test Operator DEMENSIONS: Bulletin 700-HF Relay (DPDT) Bulletin 700-HF (3PDT)
More informationAllen-Bradley 700-K40E-DJ
Bulletin Overview/Product Selection Bulletin Miniature Control Relays IEC compact industrial relay IPX Finger Protection Bifurcated contacts for low-level signals Optional integrated coil protection diode
More informationApplication Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole)
DATASHEET - FAZ-C10/2 Miniature circuit breaker (MCB), 10A, 2p, C-Char, AC Similar to illustration Part no. FAZ-C10/2 Catalog No. 278756 Eaton Catalog No. FAZ-C10/2 EL-Nummer 1695166 (Norway) Delivery
More informationMiniature Circuit Breakers for Railway Applications
Siemens AG 00 for Railway Applications BETA Low-Voltage Circuit Protection The miniature circuit breakers are used in fixed railway systems and rolling stock for protecting system components against overcurrent
More informationTeSys protection components
Description, characteristics -pole electronic thermal overload, TeSys LR9D0, 0, 08, and LR9D0S DB8880.eps 7 / & 8 Description LR9D0, 0, 08 and self-powered electronic thermal overload are designed for
More informationDigital ac/dc (24V) Input Module
Installation Instructions Digital ac/dc (24V) Input Module Catalog Number 1771-IND, Series C Topic Page Important User Information 2 Before You Begin 3 Power Requirements 3 Prevent Electrostatic Discharge
More informationMax. Short Circuit Current [ka] Standard Motor Protection High Inrush Motor Protection Motor Circuit Protection 600V C-Frame
! Bulletin 0M Motor Circuit Protectors Type Coordination 00V Current Standard Motor Protection High Inrush Motor Protection Motor Circuit Protection 00V For Use With Contactors Below (or larger) 0M-CE-A
More informationCat. No. 140M-F M-D8E-B
Motor Protection Circuit Breakers Product Selection Motor Protection Circuit Breakers Short Circuit Protection Standard Magnetic Trip ( x I e ) Motor Overload Protection Trip Class 0 0 Rated Operational
More informationOVERLOAD RELAYS POWER & ACTUATION PROVEN. series
POWER & ACTUATION OVERLOAD RELAYS series Need reliable, accurate overload and phase-loss protection for your motors? c3controls Series Bimetallic Overload Relays provide unmatched protection and can be
More informationDeltaV Bulk Power Supplies
DeltaV Distributed Control System Product Data Sheet DeltaV Bulk Power Supplies DeltaV 5 A, 10A, 20 A, 40 A Bulk Power Supplies. DeltaV 20 A, 40 A and 80 A Bulk Power Supply Redundancy Modules. Easy to
More informationBulletin 194R Fused and Non-Fused Disconnects Product Selection
Product Selection 4th Pole Modules Maximum Hp Ratings Rated 1-Phase (60 Hz) -Phase (60 Hz) DC Current [A] 10V 40V 40V 480V V 1V 0V Ref. Cat. No. Non-d 0 7. 1 0 A 194R-0-NN 60 1 0 40 B 194R-60-NN UL Class
More information140M C 2 E A63 KN CC GJ
Motor Protection Circuit Breakers Catalog Number Explanation Cat. No. Explanation Examples given in this section are for reference purposes. This basic explanation should not be used for product selection;
More informationThermal-Magnetic Circuit Breaker 2216-S
Thermal-Magnetic Circuit Breaker 226-S Description One and two pole thermal-magnetic circuit breaker in compact design with slide actuator, trip-free mechanism, various trip characteristics and optional
More informationCat. No. (Spring Clamp. Input Voltage
Bulletin -HL Product Overview/Product Selection Product Selection Bulletin -HL "Terminal Block Relay" Relay and socket assembled interface modules for high density interposing or isolation applications
More informationSolar Combiner Enclosure
Installation Instructions Solar Combiner Enclosure Catalog Numbers 1000-SB006, 1000-SB012 Topic Page Description 1 Important Safety Instructions 3 Nameplate Data 4 Planning for Installation 4 Install the
More information2-Position Cylinder Lock Operator Cat. No. 800T-H33A 800 T H31 A. Protection Rating Description T Metal, Type 4/13
2-Position Selector Switch Devices, Non-Illuminated (Bul. 800T only) 2-Position Cylinder Lock Operator Cat. No. 800T-H33A 800 T H31 A a b c d e a Protection Rating T Metal, Type 4/13 Blank C H31 H32 H33
More informationFor additional PowerFlex 4M data and general drive information, refer to the following publications:
Product Overview Providing users with powerful motor speed control in a compact, space saving design, the Allen-Bradley PowerFlex 4M AC drive is the smallest and most cost effective member of the PowerFlex
More informationIntroduction Electronic Circuit Protection ESX10-T
Introduction Electronic Circuit Protection ESX0-T Electronic circuit protection type ESX0-T is designed to ensure selective disconnection of 24VDC load systems. 24VDC power supplies, which are widely used
More informationDigital ac/dc (24V) Input Module
Installation Instructions Digital ac/dc (24V) Input Module Catalog Number 1771-IND, Series C Topic Page Important User Information 2 Before You Begin 3 Power Requirements 3 Prevent Electrostatic Discharge
More informationD-Series. Circuit Breaker
D-Series Circuit Breaker Designed for snap-on-back panel rail mounting on either a 35mm x 7.5mm, or a 35mm x 15mm Symmetrical Din Rail, allowing rapid and simple mounting and removal of the breaker. It
More informationBulletin 294 ArmorStart LT Distributed Motor Controllers Feature Diagram
Feature Diagram E Feature Diagram On/Off Switch Wiring Access LockOut/TagOut Provision HOA Keypad (optional) Status and Diagnostic LEDs Reset IP Address Switches ECM (Electronic Control Module) Gland Plate
More informationInstallation Instructions
Installation Instructions (Cat. No. 1794-TBN) 6 1 5 9 4 2 3 10 6 7 8 Component Identification 1 Female flexbus connector 2 Terminal base unit (1794-TBN) 3 Male flexbus connector 4 Keyswitch Set to the
More informationMotor-protective circuit-breaker, 3p, Ir=16-25A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A
DATASHEET - PKZM4-25 Delivery program Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection Part no. PKZM4-25 Catalog No. 222352 Eaton Catalog No. XTPR025DC1NL EL-Nummer 0004355158 (Norway)
More informationMULTI 9 System Catalog
MULTI 9 System Catalog Class 80 CONTENTS Schneider Electric Brands Description Page SectionIntroduction... Section UL 89 Listed Circuit Breakers and UL 77 Recognized SupplementaryProtectors... SectionIEC097-RatedProtectionDevices...
More informationST 200 M data sheet System pro M compact miniature circuit breakers for supplementary protection acc. to UL 1077
MINIATURE CIRCUIT BREAKERS ST 200 M data sheet System pro M compact miniature circuit breakers for supplementary protection acc. to UL 1077 The ST 200 M miniature circuit breaker provides supplementary
More informationGround Fault Current Protection Devices Prevent Costly Production Shutdowns
Ground Fault Current Protection Devices Prevent Costly Production Shutdowns Figure.1 Altech s three new series deliver multiple capabilities. In all three series, ground fault sensitivity levels range
More informationPanelView Plus/VersaView CE Terminals and Display Modules
Installation Instructions PanelView Plus/VersaView CE Terminals and Display Modules (Catalog Numbers 2711P-xxxxxx, 6182H-xxxxxx) English Inside: Overview...2 For More Information...2 Modular Components...3
More information140M C 2 N A63 KN CC GJ
Motor Circuit Protectors Product Overview/Catalog Number Explanation Product Line Overview C-Frame D-Frame F-Frame H-Frame J-Frame L-Frame N-Frame Max. Current I e A A A 00 A 0 A 00 A 00 A Current Rating
More informationCompactBlock Guard I/O EtherNet/IP Safety Modules
Installation Instructions CompactBlock Guard I/O EtherNet/IP Safety Modules Catalog Numbers 1791ES-IB8XOBV4, 1791ES-IB16 Topic Page Important User Information 2 North American Hazardous Location Approval
More informationCompactLogix Power Supplies Specifications
Technical Data CompactLogix Power Supplies Specifications 1768 CompactLogix Power Supplies Catalog Numbers 1768-PA3, 1768-PB3 1769 Compact I/O Power Supplies Catalog Numbers 1769-PA2, 1769-PB2, 1769-PA4,
More informationBulletin 194R Fused and Non-Fused Disconnects Product Selection
Product Selection 4th Pole Modules Maximum Hp Ratings Rated 1-Phase (60 Hz) -Phase (60 Hz) DC Current [A] 1V 240V 240V 480V V 12V V Ref. Non-d 0 2 7. 1 A2 194R-0-NN 60 1 0 40 B2 194R-60-NN UL Class CC
More informationMINI-PS AC/10-15DC/8
Primary-Switched Power Supply, Narrow Design Data Sheet 08/2004 MINI POWER provides: An extra narrow design, with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a
More informationApplication Instantaneous release response current 5-10 x In. Switching capacity Switching Capacity 15 ka (IEC/EN ) U e V AC 230/400
Overcurrentswitch,10A,3p,C-Char,AC Partno. FAZ-C10/3 Articleno. 278869 CatalogNo. FAZ-C10/3 Similar to illustration Deliveryprogramme Product range FAZ Application Instantaneous release response current
More informationDX 3 MCB A / 16 ka 80 A to 125 A (1,5 module per pole)
87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 DX 3 MCB 10000 A / 16 ka CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...
More informationDescription Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA
Delivery program Contactor relay, 3N/O+1N/C, DC current Part no. DILA-31(24VDC) Catalog No. 276379 Eaton Catalog No. XTRE10B31TD EL-Nummer 4130206 (Norway) Product range DILA relays Application Contactor
More informationThermal-Magnetic Circuit Breaker 4220-T...
Thermal-Magnetic Circuit Breaker 40-T... Description Single, double and three pole thermal-magnetic circuit breakers with high rupture capacity to UL 489 (5 ka), EN/IEC 60934 (6kA) and UL 077 (5 ka). With
More informationEmbedded I/O Expansion Board with 10 Outputs
Installation Instructions Embedded I/O Expansion Board with 10 Outputs Catalog Number 1799-OQ10X Topic Page Important User Information 2 Environment and Enclosure 3 About the Board 4 Install the Board
More informationApplication Techniques CENTERLINE 2100 Motor Control Centers
POWER SYSTEM CONSIDERATIONS FOR PRODUCT SELECTION Application Techniques CENTERLINE 2100 Motor Control Centers Power System Considerations for Product Selection i Power System Considerations for Product
More informationModel Number Structure
Solid State Relays with Failure Detection Function G3PC CSM_G3PC_DS_E_1_1 Refer to Safety Precautions for All Solid State Relays. Detects failures in SSR used for heater temperature control and simultaneously
More informationAllen-Bradley Drives
Overview/Product Selection Bulletin IEC Industrial Safety Relay Positively Guided/Mechanically Linked as Per IEC 947-5-1 Annex L Third Party Certification By SUVA Red Cover and Mechanically Linked Contact
More informationPGR-4300 MANUAL GENERATOR GROUND-FAULT RELAY
Tel: +1-800-832-3873 E-mail: techline@littelfuse.com www.littelfuse.com PGR-4300 MANUAL GENERATOR GROUND-FAULT RELAY REVISION 3-B-041318 Copyright 2018 by Littelfuse, Inc. All rights reserved. Document
More informationPERCENT OF RATED CURRENT
A-D Series Time Delay Values PERCENT OF RATED CURRENT NOTES: UL489 C-Series Breakers available with Delay Curves 11, 12, 14, 16, 21, 22, 24, 26, 42, 44, 46. Delay Curves 11,12,14,16,21,22,24,26,42,44,46,52,54,56:
More informationModel Number Structure
Solid State Relays with Failure Detection Function G3PC Detects failures in SSR used for heater temperature control and simultaneously outputs alarm signal. This SSR supports the safe design of heater
More informationJtec 10kA Miniature Circuit Breaker
Jtec 0kA Miniature Circuit Breaker EN 60898 The Jtec range has been enthusiastically adopted by a diverse range of customers seeking a cost effective 0kA performance. Jtec MCBs are available in a wide
More informationBulletin 700-HL 2-Pole Terminal Block Relay
Bulletin 700-HL 2-Pole Terminal Block Relay Bulletin 700-HL 2-Pole "Terminal Block Relay" Relay and socket assembled interface modules for high density interposing or isolation applications Screw terminal
More informationProduct Overview. PowerFlex 520-Series AC Drives Feature. Modular Design. Packaging and Mounting. Optimized Performance
Product Overview The PowerFlex 520-Series AC drive delivers an innovative design that is remarkably versatile and can accommodate systems ranging from standalone machines to simple system integration.
More informationMiniaturecircuitbreaker(MCB),16A,3p,B-Char,AC. Application Switchgear for industrial and advanced commercial applications.
Miniaturecircuitbreaker(MCB),16A,3p,B-Char,AC Similar to illustration Partno. FAZ-B16/3 CatalogNo. 278847 EatonCatalogNo. FAZ-B16/3 EL-Nummer 1695123 Deliveryprogram Basic function Miniature circuit-breakers
More informationProducts :: Circuit Protection :: Hydraulic/Magnetic Circuit Breakers
Products :: Circuit Protection :: Hydraulic/Magnetic Circuit Breakers Hydraulic/Magnetic Circuit Breaker B-Series B-Series PDF elibrary The B-Series hydraulic/magnetic circuit breakers are compact and
More informationG3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend
Solid State Relays with Failure Detection Function G3PC Refer to Warranty and Application Considerations (page 1), Safety Precautions (page 4), and Technical and Safety Information (page 6). Detects failures
More informationRM17UB3. Product data sheet Characteristics. voltage control relay RM17-U - range V AC. Main. Complementary
Characteristics voltage control relay RM17-U - range 183..528 V AC Main Range of product Product or component type Relay type Product specific application Relay name Relay monitored parameters Time delay
More information