Measure & Analyze MM Automatic Quality Control System (AQCS) 5881B... Technical Data *

Size: px
Start display at page:

Download "Measure & Analyze MM Automatic Quality Control System (AQCS) 5881B... Technical Data *"

Transcription

1 Measure & Analyze MM Automatic Quality Control System (AQCS) 5881B The AQCS is used in conjunction with quartz cavity pressure sensors for measuring cavity pressure on injection molding machines, and is used to monitor and control the injection molding process. Artificial intelligence has made it possible to detect the volumetric filling of a cavity during injection molding and to switch over automatically from the injection to the holding pressure phase. The measured values are digitized. The 2 thresholds, upper limit (UL), lower limit (LL) as well as the condition within the limits are monitored by software. The peak value of the pressure p ma and the pressure curve p inde integrated over time (adjustable integral limits) are shown on the display numerically as measurands and graphically as trends. The pressure curve is recorded and displayed as a graph for setting the injection molding machine. The AQCS can be connected via 8 digital inputs and 8 digital outputs to a machine control system, in order to switch automatically to holding pressure and to transmit various control commands (alarm, good/reject, operate etc.). Illuminated graphics (LCD) provide the display. The equipment complies with the safety requirements according to EN and also the EMC standards EN (interference emission) and EN (interference immunity), and is thus in conformity with the CE. Inputs and outputs are protected by varistors against electrostatic discharges (ESD). Intelligent, automatically optimized switching Maimum pressure and pressure integral monitoring Curves and trends on graphic display Auto zoom of the curve trace Documentation via RS-232C interface For direct and indirect measurement behind a pin Selectable mechanical units («bar», «psi», «Mpa») Conforming to Technical Data * Analog channel inputs 1 Scanning frequency (channel) khz 1,1 Error (with calibration) %FS <±1 Repeating error %FS <0,1 measurement and protective ground V <20 Analog monitor outputs (2 mm sockets) - Measuring amplifier output 1 Output voltage V ±10 Error repetition %FS <±0,1 measurement and protective ground V <20 Digital inputs: (electrically isolated by optocouplers) 8 Logical input level High V >14 Logicial input level Low V <8 Input current at 24 V ma 5 Input Voltage V <±30 inputs and protective ground V rms <30 Digital outputs (System: Photo MOS-relay, 4 outputs 8 in each case connected on one side) Voltage V <±42 Current loading ma <100 Current loading, pulse Impulse <0,1s ma <300 Resistance when switched on Ω <50 outputs and protective ground V rms <30 Auiliary supply Non-stabilized, electrically isolated Voltage No-load voltage V 26 at rated mains voltage and 150 ma current V 24 Current ma <300 Source resistance Ω 15 Au., GND and protective ground V rms <20 * In all Kistler documents, the decimal sign is a comma on the line (ISO 31-0:1992).

2 2 RS-232C interface (without control lines, signal ground is connected to analog measuring ground) Voltage at receiver input V <±20 Baud rates 110, 150, 300, 600, , 4800, 9600 Data bits 7 oder 8 Stop bits 1 Parity (none, even, odd) General Operating temperature range C Suply voltage VAC , ±10% Hz VA 22 Mains connection 2P+E, Protection Class I Type IEC 320C14 Dimensions without case, cassette per DIN Part 5 42TE 3HE with case (WHD) mm Weight (incl. case) kg 5,2 Charge amplifier module Measuring range, switched in steps 1, 2, 5 pc ± ±200'000 Drift pc/s <±0,05 Zero transient (Reset-Operate) pc <±1 Error (after echange, without re-calibration) %FS <±3,5 Equipment construction The AQCS has a modular design and consists of: Channel card with an epansion slot for a channel module Channel module for quartz sensors Case (table-mounted case, Switchboard installation set or 19 cassette) Power supply Front panel with display and keyboard Channel module Single-channel charge amplifier for quartz sensors Measuring range (switchable) 20, 50, 100, 200, 500, 1000, 2000 bar Sensor sensitivity adjustable 1, ,9 pc/bar Analog monitor output Block diagram Display Keyboard Piezoelectric sensor Channel card Machine control (SPS) Channel module A Module SL Supply Analog output RS-232C Printer V AC 50-60HZ 24V DC PC

3 3 Evaluation functions Monitoring of the upper and lower limits (UL, LL) is carried out using preset absolute values or in percentage values. Selection of monitoring mode Maimum cavity pressure Integral (cavity pressure over operate time) Choice of thresholds (SL, LL, UL) Manual entry or automatic calculation of limits Function Real Time On-Line SL LL Within Limits UL p ma p inde Trend p ma Trend p inde (Real Time = during the measuring cycle, On-Line = after the measuring cycle) Monitor screen Measurement screen Menu screen Mask screen Operation The AQCS is menu-driven via the keyboard and the illuminated graphic display. Up to 99 equipment settings can be stored in the nonvolatile memory and can be selected via the keyboard or via a SPC. Operating levels with protected access guarantee optimum security and ensure that only authorized personnel have access for changing the parameters. Application The AQCS is primarily intended for automatic switching from the injection to the holding pressure phase of injection molding machines as well as for process monitoring. It is ideally suitable for upgrading eisting machinery. The automatic learning phase integrated in the AQCS considerably simplifies the start-up of production and for optimizing new molds. (For learning phase description, see Operating Instructions). Attention Automatic switching is possible only by using the directly measured mold cavity pressure, since only this parameter constitutes a specific feature of the volumetric filling of the cavity. Neither the hydraulic pressure nor the nozzle pressure can be used for this. The mold cavity pressure must be measured by a sensor mounted close to the gate. The AQCS determines the optimum switching point from the change in gradient of the rise in pressure, which occurs when the cavity is volumetrically full. Fluctuations in temperature and viscosity of the melt are thus automatically compensated for. This ensures that switching takes place neither prematurely (distorted parts) nor too late (parts with high internal stresses). The AQCS determines the optimum switching point in real time, shot by shot. Process fluctuations are thus compensated for and the AQCS automatically changes the machine settings to achieve constant quality of the parts.

4 4 Connector pin assignments Digital-Inputs Pin Digital-Outputs Pin (DSUB-26P, high density) Measure (+) 2 Ready 7 ( ) 1 Hardcopy (+) 11 Alarm 17 ( ) 10 Hand / Auto (+) 20 SL 8 ( ) 19 Read config. no. (+) 4 LL 18 ( ) 3 Common Digital Output Digital-Input 5 (+) 13 Within 16 ( ) 12 Digital-Input 6 (+) 22 UL 23 ( ) 21 Digital-Input 7 p ma or p inde (+) 6 UL Kombi outside the limits ( ) 5 24 Digital-Input 8 (+) 15 not used 25 ( ) 14 Common Digital Output Konfig Nr. Auiliary voltage +24VDC unstabilized (Round connector Binder Series 681, 4-pole) Function Pin Au. +24V 1 Au. GND RS-232C interface (DSUB-25S) Function Pin Receiver RD 3 Transmitter TD 2 Signal ground 7 Screen/Protective ground Ordering key for the Automatic Quality Control System AQCS Type 5881B v v without case 00 with case Type 5749A1 10 with Switchboard installation set 20 The basic unit comprises: Channel card equipped with single-channel charge amplifier Keyboard and display Power module RS-232C Interface Menu language selectable: English/German 19" cassette housing 42TE/3HE per DIN Eample for ordering 1 AQCS with keyboard, with single-channel charge amplifier for 230 V AC mains and built into housing Type 5749A1. The correct ordering code is 1 AQCS Type 5881B10 Safety notes and notes on product liability are included in the Operating Instructions. Accessories Type Printer cable RS-232C 3 m DB-25P/DB-25P 1467A3 Cable adapter DB-9P/DB-25S 1469 Connecting cable for digital inputs Type 1471A5 and outputs Adapter for testing the digital inputs Type Z16126 and outputs Connecting cable for auiliary supply 1473A5 AQCS - PC connecting cable 1465A3 Intermediate adapter with test sockets for digital input/output Z16126 Simulator incl. cable Z15822 Spare key for equipment operation RS-232C cable with HARD WIRED HANDSHAKE 1475A3 Scope of delivery Power cord Type 1507/1508/1509 D-SUB-26 cable connector Art. No mm connector with fleible leads, black Art. No mm connector with fleible leads, red Art. No Cable connector 4-pole IP 40 Art. No (for auiliary supply AUX. +24 V)

5 5 Automatic detection of the switch-over point as soon as cavity is volumetrically filled. p p t Find the optimal switch-over point based on the cavity pressure: Traditional: Optimizing by hand 1 Set holding pressure to zero. 2 Set injection speed. 3 Choose intentionally a too low switch-over pressure (e. g. 50 bar). 4 Make a trial shot and determine the degree of volumetric filling. 5 Increase switch-over pressure, e. g. to 70 bar. 6 Make again a trial shot and determine the degree of volumetric filling. 7 Repeat steps 5 and 6 until the complete volumetric filling of the cavity is reached. Today: Molding with AQCS 1 Select a sufficiently large dosage (Melt cushion min.10 mm) 2 Holding pressure: about 2/3 of the epected holding pressure 3 Optimize remaining parameters as usual 4 Production: The AQCS switches over automatically when the mold is volumetrically full, i.e. at the optimum moment. The optimum switchover therefore also takes place when other parameters have also changed (e.g. the injection speed or melt temperature) or when parameters such as the viscosity of the melt change during production. 8 When the switch-over pressure for complete volumetric filling has been established (e. g. 112 bar), the switch-over point is optimized and only now the holding pressure can be set. 9 Each time a parameter (e. g. the injection speed or the melt temperature) is changed, the whole optimization must be redone, starting again with step 1 and whenever a parameter such as the viscosity of the melt varies during production, the quality of the parts is affected!

CoMo Logic. Electronics & Software. Single-Channel y(t) ControlMonitor. Type 5875A...

CoMo Logic. Electronics & Software. Single-Channel y(t) ControlMonitor. Type 5875A... Electronics & Software CoMo Logic Single-Channel y(t) ControlMonitor Type 5875A... The CoMo Logic monitor has a graphics display and charge mode input for monitoring time-dependent measurands in production

More information

MiniAmp. Electronics & Software. Miniature Charge Amplifier. Type 5030A...

MiniAmp. Electronics & Software. Miniature Charge Amplifier. Type 5030A... Electronics & Software MiniAmp Type 5030A... Miniature Charge Amplifier The MiniAmp Type 5030A is a single channel, industrial charge amplifier, which converts the charge signal from piezoelectric sensors

More information

DIGITAL DISPLAY. for Industry Applications. Series WAY-SSI. Key-Features:

DIGITAL DISPLAY. for Industry Applications. Series WAY-SSI. Key-Features: DIGITAL DISPLAY for Industry Applications Series WAY-SSI Key-Features: Content: Technical Data.2 Technical Drawing...2 Electrical Connection...3 Description...4 Order Code & Accessories...6 - WAY-SSI-S:

More information

PowerLogic power-monitoring units. Power Meter PM500. Technical data sheet 2006

PowerLogic power-monitoring units. Power Meter PM500. Technical data sheet 2006 PowerLogic power-monitoring units Technical data sheet 2006 Functions and characteristics E90463 The PowerLogic PM500 Power Meter provides all measurement capabilities required to monitor an electrical

More information

Temperature Switches

Temperature Switches ETS 00 Series Temperature Switch for Inline and Tank Mounting Applications Description The ETS 00 is a compact electronic temperature switch with 4-digit digital display. Pressure resistant to 8700 psi,

More information

SCP for Plastics Processing

SCP for Plastics Processing Measure & Analyze MCS SCP for Plastics Processing Modules for Signal Conditioning System Type 2853A..., 2207A..., 5063A..., 5227A..., 5613A... The SCP is a modular system for conditioning measuring signals

More information

Voltage Transducer UMT516 / MT516

Voltage Transducer UMT516 / MT516 Voltage Transducer UMT516 / MT516 True RMS AC voltage measurements Voltage auto range measurements up to 600V # Wide frequency measurement range 16 400 Hz High accuracy class 0.2 (IEC-688), 0.1 on communication

More information

ControlMonitor CoMo View

ControlMonitor CoMo View Electronics & Software ControlMonitor CoMo View Web Server for Production Monitoring Type 5863A2 The new CoMo View Type 5863A2 with integrated 5,7" touch screen color display (320x240 pixels) meets all

More information

MC 11 EB-2 Power supply cabinet with external bus, AC version

MC 11 EB-2 Power supply cabinet with external bus, AC version MC 11 EB-2 Power supply cabinet with external bus, AC version USER/MAINTENANCE MANUAL 1 SLOT 0 SLOT 1 SLOT 2 SLOT 3 SLOT 4 SLOT 5 SLOT 6 SLOT 7 SLOT 8 SLOT 9 SLOT 10 SLOT 11 EB-2 (a) MC11 (b) (c) Figures

More information

XMLR400M1P25 Pressure sensors XMLR 400bar - G 1/4-24VDC ma - PNP - M12

XMLR400M1P25 Pressure sensors XMLR 400bar - G 1/4-24VDC ma - PNP - M12 Characteristics Pressure sensors XMLR 400bar - G 1/4-24VDC - 4..20 ma - PNP - M12 Complementary Current consumption Electrical connection Type of output signal Analogue output function Discrete output

More information

Screw terminal panels, Relay output boards, connection cables

Screw terminal panels, Relay output boards, connection cables Screw terminal panels, Relay output boards, connection cables How important are cables and terminal panels? When the PC runs important controlling and regulating tasks in a processing system, then data

More information

The PM1000 series is a universal 4 digit LED plug-on display for transmitters with 4-20mA 2 wire output and fitted with DIN43650 connector.

The PM1000 series is a universal 4 digit LED plug-on display for transmitters with 4-20mA 2 wire output and fitted with DIN43650 connector. PM1000 SERIES PLUG-ON DISPLAY BRIGHT LED DISPLAY INDICATION RANGE -999 TO +9999 FITS TO DIN 43650 CONNECTOR PLUG-ON TO ANY TRANSMITTER WITH 4-20MA OUTPUT EASY TO SCALE ON SITE ROBUST DESIGN SET POINT OPTION

More information

Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X

Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X Modular solution based on the combination of two units: VMU-E analysis unit and VMU-X universal power supply and RS485 communication unit.

More information

Isolated Process Current Input 7B32 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated Process Current Input 7B32 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM Isolated Process Current Input 7B32 FEATURES Interfaces, amplifies and filters a process-current input. Module provides a precision output of either +1 V to +5 V or 0 V to +10 V, linear with temperature.

More information

Isolated Process Current Input with Loop Power 7B35

Isolated Process Current Input with Loop Power 7B35 Isolated Process Current Input with Loop Power 7B35 FEATURES Single-channel signal conditioning current input module that interfaces with two-wire transmitters. Module provides a precision output of either

More information

ControlMonitor CoMo Net

ControlMonitor CoMo Net Electronics & Software ControlMonitor CoMo Net Web Server for Production Monitoring Type 5863A1 Press-fit processes are frequently used joining techniques. However, subsequent nondestructive testing of

More information

Energy Management Modular Energy meters Type EM2-96

Energy Management Modular Energy meters Type EM2-96 Energy Management Modular Energy meters Type EM2-96 Product Description µp-based modular energy meter with a built-in configuration key-pad. The energies are both partial and total counted. The housing

More information

02/11/2015

02/11/2015 35 mm - 1 Relay 8A OUR1 Part number 88867105 Multi-function or mono-function Multi-range Multi-voltage Relay output 1 or 2 : 8 A - 250 V (10 A UL) LED status indicator Option of connecting an external

More information

Isolated, Field Configurable Analog Input 6B11 / 6B11HV FEATURES APPLICATIONS PRODUCT OVERVIEW

Isolated, Field Configurable Analog Input 6B11 / 6B11HV FEATURES APPLICATIONS PRODUCT OVERVIEW Isolated, Field Configurable Analog Input 6B11 / 6B11HV FEATURES Single-channel isolated signal-conditioning modules. Accepts outputs from Thermocouple, millivolt, volt and current signals. Complete microcomputer-based

More information

Isolated Voltage Input 7B31 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated Voltage Input 7B31 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM Isolated Voltage Input 7B31 FEATURES Interfaces, amplifies, and filters unipolar and bipolar voltage inputs. Module provides a precision output of either +1 V to +5 V or 0 V to +10 V, linear with temperature.

More information

DINALOG A 144 x 36 A1400 Light-Strip Indicator

DINALOG A 144 x 36 A1400 Light-Strip Indicator DINALOG A x 6 A00 Light-Strip Indicator -9-0-0 /.00 Front panel dimensions: x 6 mm Light-strip indicator with 7 high-contrast LEDs Red LED display color Digital display range for portrait format: 999 to

More information

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features TRACKER 240 SERIES Load Cell and Weighing Indicators A Precision Measurement Instrument with Outstanding Features TRACKER 240 SERIES INDICATORS Ratiometric Measurement Tare and Auto Transducer Excitation

More information

D1000M SERIES FOR MODBUS SENSOR TO COMPUTER INTERFACE MODULES

D1000M SERIES FOR MODBUS SENSOR TO COMPUTER INTERFACE MODULES D1000M SERIES FOR MODBUS SENSOR TO COMPUTER INTERFACE MODULES D1000 FEATURES Complete sensor to RS-232/RS-485 interface. 500V rms analog input isolation. 15 bit measurement resolution. Continuous self-calibration;

More information

DENISON HYDRAULICS Jupiter Power Supply Accessory Series S

DENISON HYDRAULICS Jupiter Power Supply Accessory Series S DENISON HYDRAULICS Jupiter Power Supply Accessory Series S20-11715-0 Jupiter Power Supply Accessory S20-11715-0 Jupiter Power Supply Accessory w/ Driver Card S20-11712 Publ. 9-AM686 E-Mail: denison@denisonhydraulics.com

More information

Conductive Sensors 2 to 4-point level controller Type CL with teach-in

Conductive Sensors 2 to 4-point level controller Type CL with teach-in Conductive Sensors to 4-point level controller Type CL with teach-in Conductive level controller Teach-in of sensitivity operating resistance from 0Ω to 0KΩ Multiple combinations of filling and emptying

More information

JUMO Quantum PID100/PID200/PID300

JUMO Quantum PID100/PID200/PID300 Data sheet 702020 Page 1/12 JUMO Quantum PID100/PID200/PID300 Universal PID Controller Series Brief description The Quantum series is available in the three DIN formats 48 mm x 48 mm, 48 mm x 96 mm, and

More information

Isolated, Process Current Output 7B39 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated, Process Current Output 7B39 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM Isolated, Process Current Output 7B39 FEATURES Interfaces, isolates and filters a 0 V to + 10 V or +1 V to +5 V input signal. Provides an isolated process current output of 0 ma to 20 ma or 4 ma to 20

More information

Electronic SD1, AS 8, ASR 14, ASR 20

Electronic SD1, AS 8, ASR 14, ASR 20 Electronic SD1, AS 8, ASR 14, ASR 20 2 Electronic SD1, AS 8, ASR 14, ASR 20 Contents Page List of contents..................................................... 3 Function and characteristics.........................

More information

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3 INSTALLATION MANUAL LC 200 Electronic Overload Guard Software versione PW0501 R 0.3 CONTENTS MAIN FEATURES LC 200 TECHNICAL FEATURES Page 2 SYMBOLS Page 3 WARNINGS Page 3 IDENTIFICATION DATA PLATE Page

More information

PSM-ME-RS232/TTY-P Interface converter for RS-232 to TTY transmission systems

PSM-ME-RS232/TTY-P Interface converter for RS-232 to TTY transmission systems Interface converter for RS- to transmission systems. Short Description The rail-mountable and compact interface converters have been designed especially for industrial use in the switch cabinet or switch

More information

PU5 5-digit digital panel meter in 96x48 mm (BxH) Universal measuring inputs: Pt100, current, voltage, shunt, thermocouple, resistance

PU5 5-digit digital panel meter in 96x48 mm (BxH) Universal measuring inputs: Pt100, current, voltage, shunt, thermocouple, resistance PU5 5-digit digital panel meter in 96x48 mm (BxH) Universal measuring inputs: Pt100, current, voltage, shunt, thermocouple, resistance red display of -9999 99999 digits installation depth: 120 mm without

More information

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882 1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882 This manual is intended for use in support of installation, commissioning and configuration of the 1/32-DIN Temperature

More information

USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER TPLR-96 Series

USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER TPLR-96 Series USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER TPLR-96 Series TEMPSEN DEVICES Plot No : 2&3, Balaji Nagar, 4 th Street, Mettukuppam, Thoraipakkam, Chennai-600097 Tele fax : +91-44-24581758,Mobil

More information

Display and Monitoing Units

Display and Monitoing Units Display and Monitoing Units DISPLAY AND MONITOrING UNITS 13 The universal display unit HDA 5500 provides the means of visualizing and further processing the signals from our sensors. The unit is designed

More information

Isolated, Voltage or Current Input 7B30 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated, Voltage or Current Input 7B30 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM Isolated, Voltage or Current Input 7B30 FEATURES Interfaces, amplifies and filters unipolar and bipolar millivolt and voltage inputs. Provides a protected precision output of either +1 V to +5 V or 0 V

More information

ABL8BBU24200 battery control module V DC - 24 V - 20 A - for regulated SMPS

ABL8BBU24200 battery control module V DC - 24 V - 20 A - for regulated SMPS Characteristics battery control module - 24..28.8 V DC - 24 V - 20 A - for regulated SMPS Main Range of product Product or component type Input voltage Output voltage Maximum output current Phaseo Battery

More information

Electronic Preset Counter with 2 Presets and Print interface. NE213 Prog Features

Electronic Preset Counter with 2 Presets and Print interface. NE213 Prog Features Electronic Preset Counter with 2 Presets and Print interface NE21 Prog. 09 Features Order designation Order no. Interface RS22 Models Connection Functions LED-preset counter with 2 presets Batch counter

More information

Programmable controller MCX06C

Programmable controller MCX06C MAKING MODERN LIVING POSSIBLE Technical brochure Programmable controller MCX06C Danfoss range of universal MCX programmable controllers offers the functionality and reliability you need to get the best

More information

TRACKER 220 SERIES. Digital Panel Indicators. A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement

TRACKER 220 SERIES. Digital Panel Indicators. A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement TRACKER 220 SERIES Digital Panel Indicators A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement TRACKER 220 SERIES INDICATORS Universal Input Analogue Output

More information

This data sheet is only valid in association with the IL SYS INST UM E user manual.

This data sheet is only valid in association with the IL SYS INST UM E user manual. Inline analog input terminal, 4 inputs for connecting voltage signals Data sheet 8081_en_01_C01 PHOENIX CONTACT 2015-04-14 1 Description The terminal is designed for use within an Inline station. It is

More information

The Tracker 220 Series A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement

The Tracker 220 Series A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement Acquisition Measurement Control The Tracker 220 Series A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement TRACKER 220 SERIES INDICATORS Universal Input

More information

MCX06C Programmable controller

MCX06C Programmable controller Data sheet MCX06C Programmable controller MCX06C is an electronic controller that holds all the typical functionalities of MCX controllers in the 32x74 mm standard size: programmability connection to the

More information

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description Configurable signal duplicator Data sheet 102382_en_03 PHOENIX CONTACT 2012-05-02 1 Description The MINI MCR-SL-UI-2I(-SP)(-NC) configurable signal duplicator is used to electrically isolate, condition,

More information

Features. Description. Applications

Features. Description. Applications Description Features The electronic loads of the ZSAC series are optimized for the practical use in laboratories, manufacturing and quality control. Power: Voltage: Current: 400W... 12600W 260V... 440V

More information

Energy Management Modular Universal Utility Meter and Power Analyzer Type WM24-96

Energy Management Modular Universal Utility Meter and Power Analyzer Type WM24-96 Energy Management Modular Universal Utility Meter and Power Analyzer Type WM24-96 Class 1 (active energy) Class 2 (reactive energy) Accuracy 0.5% RDG (current/voltage) Universal utility meter and power

More information

USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER MODEL : ARC2020

USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER MODEL : ARC2020 USER MANUAL MULTI COLOR MODEL : ARC2020 ACCSYS ELECTRONICS 140/6B, GOLDEN INDUSTRIAL ESTATE, JAWAHARLAL NEHRU ROAD, GERUGAMBAKKAM, CHENNAI - 600122 Tel: 044 60505599 / 60505511 E-mail : sales@accsyselectronics.com

More information

MID approval no. DE-08-MI004-PTB004 Date of release

MID approval no. DE-08-MI004-PTB004 Date of release 1. Identification Energy and Flow Computer Flow rate and energy calculator for liquids, gases and water steam E-DB-1000-700-01 MID approval no. DE-08-MI004-PTB004 Date of release 04.01.08 2. Area of Application

More information

Conductive Sensors 2 to 4-point level controller Type CL with teach-in

Conductive Sensors 2 to 4-point level controller Type CL with teach-in Conductive Sensors to -point level controller Type CL with teach-in Conductive level controller Teach-in of sensitivity operating resistance from 0Ω to 0KΩ Multiple combinations of filling and emptying

More information

MCX08M2 Programmable controller

MCX08M2 Programmable controller Data sheet MCX08M2 Programmable controller MCX08M2 is an electronic controller that holds all the typical functionalities of MCX controllers in the compact size of 8 DIN modules: programmability connection

More information

MSR 2400R. Rugged Power System for Military and Heavy Duty Applications

MSR 2400R. Rugged Power System for Military and Heavy Duty Applications MSR 2400R Rugged Power System for Military and Heavy Duty Applications 2400 W modular power system Power supply or battery charging systems Parallel n+1 connection, up to 90A Series connection, up to 360VDC

More information

PRODIS. PD-ADC Digital Process Meter for analog Sensors. Digital Process Meters. Datasheet

PRODIS. PD-ADC Digital Process Meter for analog Sensors. Digital Process Meters. Datasheet Digital Process Meters Digital Process Meter for analog Sensors Datasheet Copyright ASM GmbH Am Bleichbach 18-24 85452 Moosinning Germany The information presented in this data sheet does not form part

More information

Displays Transducers. Displays and transducers

Displays Transducers. Displays and transducers JJ Displays JJ Transducers Displays and transducers DS_Displays_and_transducers 06/2016 225 Displays and transducers Our electronic devices for flow and volume measurement are suitable for all SIKA flow

More information

MINI MCR-SL-UI-2I(-SP)(-NC)

MINI MCR-SL-UI-2I(-SP)(-NC) Data Sheet 03/2005 Product Description Features Configurable signal duplicator MINI MCR-SL-UI-2I(-SP)(-NC) is used to electrically isolate, condition, amplify, and filter analog standard signals. On the

More information

LBVR1718. Description. Features channel paperless recorder

LBVR1718. Description. Features channel paperless recorder LBVR1718 18 - channel paperless recorder Description It is the world first paperless recorder of the same size in highest resolution 640x480 pixels VGA TFT display, infrared detector, maximum 18 channels,

More information

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment FAST SHIPPING AND DELIVERY TENS OF THOUSANDS OF IN-STOCK ITEMS EQUIPMENT DEMOS HUNDREDS OF MANUFACTURERS SUPPORTED

More information

Strain Gauge Converter

Strain Gauge Converter EN Z-SG General Description Module Z-SG is a strain gauge signal converter. Measurements taken using the 6-wires or 4-wires technique are available through Modbus-RTU serial protocol or the analog output.

More information

Dual Channel Monitor for Measurement of Speed and Ratio with SIL1 requirements Series D224.xx

Dual Channel Monitor for Measurement of Speed and Ratio with SIL1 requirements Series D224.xx D224 Dual Channel Monitor for Measurement of Speed and Ratio with SIL1 requirements Series D224.xx D224 Front View KEY FEATURES SIL1 / IEC 61508:2010 compliant Dual Channel Speed and Ratio Monitor with

More information

Isolated Wideband Voltage Input 3B40 / 3B41 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated Wideband Voltage Input 3B40 / 3B41 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM Isolated Wideband Voltage Input 3B40 / 3B41 FEATURES Interfaces, amplifies, protects& filters wide-bandwidth (h0 khz) single-channel analog voltage inputs. Module provides simultaneous precision voltage

More information

Flow Computer compart DXF 351. Universal Application for Gas, Steam and Liquids

Flow Computer compart DXF 351. Universal Application for Gas, Steam and Liquids Technical Information TI 032D/06/e Nr. 50072927 Flow Computer compart DXF 351 Universal Application for Gas, Steam and Liquids Easy Fast commissioning using Quick Setup and help functions E+H programming

More information

ComoNeo. Electronics & software. System for process monitoring and process optimization in plastic injection molding applications. Type 5887A...

ComoNeo. Electronics & software. System for process monitoring and process optimization in plastic injection molding applications. Type 5887A... Electronics & software ComoNeo System for process monitoring and process optimization in plastic injection molding applications Type 5887A... ComoNeo is a process monitoring system made by Kistler that

More information

ComoNeo. Electronics & Software. System for Process Monitoring and Process Optimization in Plastic Injection Molding Applications. Type 5887A...

ComoNeo. Electronics & Software. System for Process Monitoring and Process Optimization in Plastic Injection Molding Applications. Type 5887A... Electronics & Software ComoNeo System for Process Monitoring and Process Optimization in Plastic Injection Molding Applications Type 5887A... ComoNeo is a process monitoring system made by Kistler that

More information

E101 - Strain Gauge Transducer Display Module. Contents

E101 - Strain Gauge Transducer Display Module. Contents E101 - Strain Gauge Transducer Display Module Contents Torque Transducer Display Interface: TSE3249R Strain Gauge Transducer Display Interface [E101] Operating Guide: TSE2097V (Includes Introduction, Description

More information

Isolated, Voltage or Current Input 7B41 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated, Voltage or Current Input 7B41 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM Isolated, Voltage or Current Input 7B41 FEATURES Interfaces, amplifies and filters unipolar and bipolar voltage inputs. Module provides a precision output of either +1 V to +5 V or 0 V to +10 V. All 7B41

More information

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER The PM174 is a compact, multi-function, three-phase AC powermeter and power quality analyzer specially designed to meet the requirements of users ranging

More information

MULTI-POLE PHOTOVOLTAIC SYSTEMS. COMPACT and MODULAR Housing

MULTI-POLE PHOTOVOLTAIC SYSTEMS. COMPACT and MODULAR Housing MULTI-POLE Lightning Current and Surge Arresters for PHOTOVOLTAIC SYSTEMS Class I / (B+C) and Class II / (C) COMPACT and MODULAR Housing 44 PV ISPRO BS(R) 12,5 The PV ISPRO BS(R) 12,5 series of over voltage

More information

SIPROTEC easy 7SJ45 Numerical Overcurrent Protection Relay Powered by CTs

SIPROTEC easy 7SJ45 Numerical Overcurrent Protection Relay Powered by CTs SIPROTEC easy 7SJ4 Numerical Overcurrent Protection Relay Powered by CTs Function overview Fig. /1 Description The SIPROTEC easy 7SJ4 is a numerical overcurrent protection relay which is primarily intended

More information

GFM TIO GFC TIO. GFM with TIO Mounted. GFC with TIO Mounted TOTALIZER INPUT/OUTPUT FLOW MONITOR/CONTROLLER. Design Features

GFM TIO GFC TIO. GFM with TIO Mounted. GFC with TIO Mounted TOTALIZER INPUT/OUTPUT FLOW MONITOR/CONTROLLER. Design Features TOTALIZER INPUT/OUTPUT FLOW MONITOR/CONTROLLER GFM GFM with Mounted GFC GFC with Mounted Design Features n Displays instantaneous, total and accumulated flow rates. n Built-in Flow Linearizer (10 point

More information

SITOP in the SIMATIC Design

SITOP in the SIMATIC Design Siemens AG 2017 /2 Introduction /3 1-phase, 24 V DC (for S7-300 and ET 200M) /9 1-phase, 24 V DC (for S7-1200) /11 1-phase, 24 V DC (for S7-1500 and ET 200MP) /14 3-phase, 24 V DC (ET 200pro) Siemens KT

More information

MBP68300 SERIES. AC-distribution, Static Switch and Manual Bypass for DAC60000 Dual Inverters. BPU69000 Dual External static switch Plug-in unit

MBP68300 SERIES. AC-distribution, Static Switch and Manual Bypass for DAC60000 Dual Inverters. BPU69000 Dual External static switch Plug-in unit MBP68300 SERIES AC-distribution, Static Switch and Manual Bypass for DAC60000 Dual Inverters Modular Construction AC-distribution 3pcs of MCBs Manual bypass switch BPU69000 Dual External static switch

More information

MINI MCR-SL-UI-REL(-SP)

MINI MCR-SL-UI-REL(-SP) Configurable Threshold Value Switch Data Sheet 11/2004 Method of Operation The configurable 3-way threshold value switch MINI MCR-SL-UI-REL(-SP) is used to control and monitor analog standard signals.

More information

DATASHEET. Ultra Capacitor Charger, UCC-4

DATASHEET. Ultra Capacitor Charger, UCC-4 DATASHEET Ultra Capacitor Charger, UCC-4 Easy installation Monitoring and surveillance of operation Balancing to save energy 90-450 V DC 3.5A Output Modular Ultra Capacitor system Document no.: 4921260003

More information

Isolated Voltage Input 3B30 / 3B31 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated Voltage Input 3B30 / 3B31 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM Isolated Voltage Input 3B30 / 3B31 FEATURES Interfaces, amplifies, & filtersanalog input voltages. Narrow-bandwidth (3Hz) single-channel single conditioning. Module provides simultaneous precision voltage

More information

ABB Instrumentation. Specification DataFile COMMANDER 100. the-easy-to use 1. /8 DIN controller with extensive application capabilities

ABB Instrumentation. Specification DataFile COMMANDER 100. the-easy-to use 1. /8 DIN controller with extensive application capabilities COMMANDER Universal Process Controller Specification DataFile PID controller with one shot autotune single loop, heat/cool and ramp/soak as standard Quick code, front face or PC configuration easy commissioning

More information

ABL8BBU24400 battery control module V DC - 24 V - 40 A - for regulated SMPS

ABL8BBU24400 battery control module V DC - 24 V - 40 A - for regulated SMPS Characteristics battery control module - 24..28.8 V DC - 24 V - 40 A - for regulated SMPS Main Range of product Product or component type Input voltage Output voltage Maximum output current Complementary

More information

MINI MCR-SL-MUX-V8-FLK 16

MINI MCR-SL-MUX-V8-FLK 16 Multiplexer Data sheet 445_en_4 PHOENIX CONTACT 22-5-2 Description The MINI Analog multiplexer can be used to generate one analog output from up to eight input signals. During cyclical execution, 8, 6,

More information

Strain gauge Measuring Amplifier GSV-1A8. Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB

Strain gauge Measuring Amplifier GSV-1A8. Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB Strain gauge Measuring Amplifier GSV-A8 Instruction manual GSV-A8, GSV-A8USB, GSV-A6USB GSV-A8USB SubD5 (front side) GSV-A8USB M2 (front side) GSV-A6USB (rear side) GSV-A8USB K6D (front side) Version:

More information

Programmable controller Type MCX06C

Programmable controller Type MCX06C Programmable controller Type Danfoss range of universal MCX programmable controllers offers the functionality and reliability you need to get the best out of your heating, ventilation, air-conditioning

More information

Energy Management Modular DC Energy analyzer Type VIM-E and VIM-X

Energy Management Modular DC Energy analyzer Type VIM-E and VIM-X Energy Management Modular DC Energy analyzer Type VIM-E and VIM-X Modular solution based on the combination of two units: VIM-E analysis unit and VIM-X universal power supply and RS485 communication unit.

More information

For full product information, visit Use the SpeedSpec code or scan the QR Code for quick access to the specific web page.

For full product information, visit  Use the SpeedSpec code or scan the QR Code for quick access to the specific web page. R Safety Monitoring Relays For full product information, visit www.sti.com. Use the SpeedSpec code or scan the QR Code for quick access to the specific web page. Dual-Channel Safety Monitoring Relay Power

More information

Micro Motion Model 7950 and Model 7951 Signal Converters

Micro Motion Model 7950 and Model 7951 Signal Converters Product Data Sheet PS-001316, Rev. B April 2013 Micro Motion Model 7950 and Model 7951 Signal Converters Micro Motion Model 7950 and Model 7951 signal converters are the perfect complement to Micro Motion

More information

LVX Control Unit. Features:

LVX Control Unit. Features: Date 2013-02-28 Control Unit Features: Most parameters can be defined as required for your interfaces. You decide which information is output and how. Fast cycle times, just a few µs/beam. Maximum beam-count

More information

RE17LAMW on-delay timing relay - 1 s..100 h V AC/DC - solid state output

RE17LAMW on-delay timing relay - 1 s..100 h V AC/DC - solid state output Characteristics on-delay timing relay - 1 s..100 h - 24..240 V AC/DC - solid state output Complementary Control type Voltage range Main Range of product Product or component type Discrete output type Width

More information

RTU560 Connections and Settings DIN Rail RTU 560CIG10

RTU560 Connections and Settings DIN Rail RTU 560CIG10 Connections and Settings DIN Rail RTU 560CIG10 Application, characteristics and technical data have to be taken from the hardware data sheet: 560CIG10 1KGT 150 719 Operation The 560CIG10 is a DIN rail

More information

Iso DIN. User Manual. 1 channel Earth Fault Monitoring

Iso DIN. User Manual. 1 channel Earth Fault Monitoring Page 1 of 5 2017 03 20 User Manual Iso DIN Iso DIN User Manual 1 channel Earth Fault Monitoring Megacon AB Ranhammarsvägen 20 S 168 67 Bromma Sweden Tel: 08 402 42 50 sales@megacon.se www.megacon.se eee

More information

Trident and Trident X2 Digital Process and Temperature Panel Meter

Trident and Trident X2 Digital Process and Temperature Panel Meter Sign In New User ISO 9001:2008 Certified Quality System Home Products Online Tools Videos Downloads About Us Store Contact Policies Trident and Trident X2 Digital Process and Temperature Panel Meter Products

More information

signo 727 SSI Operating Instructions Position-Indicator with/without limit values and SSI input from absolute encoder

signo 727 SSI Operating Instructions Position-Indicator with/without limit values and SSI input from absolute encoder Operating Instructions signo 727 SSI Position-Indicator with/without limit values and SSI input from absolute encoder Contents 1. Safety instructions 1 2. Mounting of the position indicator 2 2.1 Mounting

More information

PCD3.C90. Date Modification Asked by: Version E/A Bus Connector PCD2.K106 change to PCD3.K106 Müller.R 1.1

PCD3.C90. Date Modification Asked by: Version E/A Bus Connector PCD2.K106 change to PCD3.K106 Müller.R 1.1 Manual PCD3.C90 Revision History Date Modification Asked by: Version 14.09.09 E/A Bus Connector PCD2.K106 change to PCD3.K106 Müller.R 1.1 22.09.09 Added E/A Bus Connector PCD3.K116 Müller.R 1.2 06.01.10

More information

Output Signal Active Note DC V. Electrical Data Power Supply DC V, ±10%, 1.4 W

Output Signal Active Note DC V. Electrical Data Power Supply DC V, ±10%, 1.4 W Differential Pressure Sensor (Air) Differential pressure transmitter with 8 selectable ranges 0 to 5/10 V, 4 to 20 ma outputs and Modbus functionality. NEMA 4X / IP65 rated enclosure. For monitoring the

More information

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m Characteristics I/O distributed module OTB - Modbus non isolated serial link - 0..10 m Complementary Topology Bus length Main Number of devices per segment 0...32 Data format Parity Discrete input voltage

More information

MINI MCR-SL-RPS-I-I. Repeater power supply, active. Data sheet. 1 Description

MINI MCR-SL-RPS-I-I. Repeater power supply, active. Data sheet. 1 Description Repeater power supply, active Data sheet 09_en_0 PHOENIX CONTACT 0--0 Description The. mm wide... repeater power supply supplies transmitters in the field and electrically isolates the input signal from

More information

Appearance Size (mm) Power supply voltage Model (W H D) 100 to 240 VAC K3SC to 240 VAC

Appearance Size (mm) Power supply voltage Model (W H D) 100 to 240 VAC K3SC to 240 VAC Interface Converter A compact converter that allows communications between RS-C/USB and RS-/8 devices. Ideal for industrial applications. Allows communications between RS-C/USB (Universal Serial Bus) and

More information

Multifunction Transducer MT440

Multifunction Transducer MT440 Multifunction Transducer MT440 Voltage and current auto range measurements up to 600V, 12.5A Universal wide auxiliary power supply range 24 300 Vdc, 40 276 Vac Power accuracy class 0.5 (EN 60 688), Up

More information

895/896M Frequency Output Math Modules

895/896M Frequency Output Math Modules 895/896M Frequency Output Math Modules Application Example Both models are designed for integrator/totalizer applications. The 896M is ideal for demand metering applications. With one high speed pulse

More information

Multifunctional time delay relay MFT U31S, MFT U41SE

Multifunctional time delay relay MFT U31S, MFT U41SE 8 Functions, 8 time ranges Multivoltage: 24 Vac / dc 110... 240 Vac 2 output contacts MFT U31S Functions E Delay on E Delay on - version with control contact as opening contact A Delay off without auxiliary

More information

Wide Bandwidth Strain Gage Input 3B18 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Wide Bandwidth Strain Gage Input 3B18 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM Wide Bandwidth Strain Gage Input 3B18 FEATURES Wideband (20 khz) single-channel signal conditioning module. Module Bandwidth is user-selectable between 20 khz and 100Hz, with user-supplied filter caps

More information

onlinecomponents.com

onlinecomponents.com Repeater for RS-485 2-Wire Systems INTERFACE Data Sheet 102964_C01_en 1 Description The PSI-REP-RS485W2 DIN-rail mountable, modular RS-485 repeater is designed to meet the high requirements associated

More information

Versatile, Automatic RCL Meters

Versatile, Automatic RCL Meters Versatile, Automatic RCL Meters Technical Specifications PM 6306 / PM 6304 / PM 6303A PM 6306 and PM 6304 Versatile component measurement and testing Easy to use, at-a-glance display Test frequencies,

More information

Digital Indicator Solutions

Digital Indicator Solutions Digital Indicator Solutions Loop-Powered Attachable Compact Attachable Loop-Powered Smart Compact System Loop-Powered Compact Smart System Intelligent Smart System "Intelligent" Options Dual & Display

More information

CM Series. Most Diverse and Flexible Line of Coded Magnetic Safety Interlock Switches and Controllers. Description. Safety Interlock Switches

CM Series. Most Diverse and Flexible Line of Coded Magnetic Safety Interlock Switches and Controllers. Description. Safety Interlock Switches R Safety Interlock Switches CM Series CM For full product information, visit www.sti.com. Use the SpeedSPEC Code for quick access to the specific web page. Most Diverse and Flexible Line of Coded Magnetic

More information

/8 DIN Universal Process Indicator

/8 DIN Universal Process Indicator Data Sheet SS/_ High visibility LED display the clearest view of your process status.% measurement accuracy precise indication of process measurement Analog and relay outputs as standard alarm and retransmission

More information