T2314, T2414. Instruction Manual

Size: px
Start display at page:

Download "T2314, T2414. Instruction Manual"

Transcription

1 Atmospheric pressure transmitter T2314, T2414 with RS232 / RS485 serial output Instruction Manual

2 Instruction Manual Device type Pressure Output Galvanic isolated output T2314 RS232 - T2414 RS485 Device is designed for measurement of atmospheric pressure at hpa, PSI, inhg, mbar, oz/in 2, mmhg, inh 2 O and kpa. It is possible to set pressure correction for altitude (offset). Device setting is provided by user s software, see latter. Device T2314 communicate via link RS232, device T2414 via link RS485. Supported communication protocols are Modbus RTU, protocol compatible with standard Advantech-ADAM and ARION. Devices are preset from manufacturer to Modbus RTU communication protocol. If you would like to use different communication protocol then Modbus RTU, it is necessary preset them throw user s software see latter. Pressure sensor is placed inside the electronic case. Measured value is optionally shown on LCD display. Display can be switched OFF too. Please read instruction manual before the first device connection. Use user s software Tsensor for setting of all device parameters (recommended). It is free to download at It supports make the adjustment of the device too. This procedure is described at file Calibration manual.pdf which is installed commonly with the software. Change of some parameters is possible to do without user s software with Windows hyperterminal (change of communication protocol, its parameters, LCD display setting). It is described in file Description of communication protocols of Txxxx series which is free to download at the same address. Device setting from the manufacturer If special setting was not required in the order device is set from the manufacturer to the following parameters: communication protocol: device address: communication speed: display: pressure unit: correction for altitude: Device installation Modbus RTU 01H 9600Bd, without parity, 2 stop bits switched ON hpa 0 hpa (absolute pressure) Device is designed for wall mounting. There are two mounting holes at the sides of the case. Device T2314 (RS232) is supplied with connection cable equipped with connector for connection to RS232 interface. For T2414 device (RS485) it is recommended to use shielded twisted copper cable (e.g. SYKFY). Outside diameter of the cable must be from 3 to 6.5 mm, maximal length 1200m. The cable must be located at indoor rooms. Don t connect device while power supply voltage is on. Interconnection terminals are accessible after unscrewing four screws and removing the lid. Lace the cable through a gland at the case wall. Connect the cable to terminals with respecting the signal polarity (see figure). Terminals are self-clamping and can be opened by a suitable screwdriver. For the opening, insert the screwdriver to smaller terminal hole and lever by him. Do not forget to tighten glands and case lid with inserted packing after cables connecting. It is necessary for warranting of protection IP54. Working position: communication cable is entering from the top side. 2 IE-SNC-T23(4)14-01

3 Nominal cable impedance should be 100 Ω, loop resistance max. 240 Ω, cable capacity max. 65 pf/m. Suitable cable is e.g. SYKFY 2x2x0.5 mm 2, where one wire pair serves for device powering and the other pair for communication link. The cable should be led in one line, i.e. NOT to tree or star. Termination resistor should be located at the end. For short distance other topology is allowed. Terminate the network by a termination resistor. The value of the resistor is recommended about 120 Ω. For short distance termination resistor can be left out. The cable should not be led in parallel along power cabling. Safety distance is up to 0.5 m, otherwise undesirable induction of interference signals can appear. Electrical system (wiring) may do only worker with required qualification by rules in operation. Info mode If in doubt of setting of installed device, verification of its address is enabled even without using computer. Power should be connected. Devices with RS232 interface have address always set to one. Unscrew device cover and shortly press button next to connection terminals (jumper should be opened). Actual adjusted address of the device is displayed on LCD display at decimal base. Next press of button exits info mode and actual measured values are displayed. Note: No measurement and communication is possible during info mode. If device stays in info mode for longer than 15 s, device automatically returns to measuring cycle. Setting of pressure correction for altitude If there is necessary to read value of atmospheric pressure corrected with respect to altitude, it is possible to set corresponding pressure offset for this altitude. It is possible to do it with Users software. This value is then automatically added to measured pressure value. The resultant value of pressure with added correction for altitude must be between 300 hpa and 1350 hpa (from PSI to PSI). Outside this range device sends value of Error 2! IE-SNC-T23(4)

4 Dimensions T2314 RS232 T2414 RS485 4 IE-SNC-T23(4)14-01

5 Typical application wiring, connection of terminals T power from communication port T power from external voltage source T2414 RS485 IE-SNC-T23(4)

6 Description of communication protocols Detailed description of each communication protocols including examples of communication is available in individual document Description of communication protocols of Txxxx series which is free to download at Note: After switching ON the power of the device it can last up to 2 s before the device starts to communicate and measure! Modbus RTU Control units communicate on master-slave principle in half-duplex operation. Only master can send request and only addressed device responds. During sending of request no other slave station should respond. During communication, data transfer proceeds in binary format. Each Byte is sent as eight bit data word in format: 1 start bit, data word 8 bit (LSB first), 2 stop bits 1, without parity. Device supports communication speed from 110Bd to Bd. Sent request and response have syntax: ADDRESS OF DEVICE FUNCTION Modbus CRC Supported functions 03 (0x03): Reading of 16-bit registers (Read Holding Registers) 04 (0x04): Reading of 16-bit input gates (Read Input Registers) 16 (0x10): Setting of more 16-bit registers (Write Multiple Registers) Jumper and button Jumper and button are located next to connection terminals. If communication protocol Modbus is selected the function of jumper and button is as follows: Jumper opened device memory is protected from writing, from device side it is only enabled to read measured value, writing to memory is disabled (no change of device address, communication speed and LCD setting is enabled) Jumper closed writing to device memory is enabled by means of User s software Jumper opened and button shortly pressed device goes to Info mode, see chapter Info mode Jumper closed and button pressed for longer than six seconds causes restoring of manufacturer setting of communication protocol, i.e. sets Modbus RTU communication protocol, device address sets to 01h and communication speed to 9600Bd (after button press there is def message blinking at LCD display. Six seconds later message def stays shown, it means manufacturer setting of communication protocol is done). 1 Device sends two stop bits, for receive one stop bit is enough. 6 IE-SNC-T23(4)14-01

7 Modbus registers of the device Variable Unit Address[hex] X Address[dec] X Format Size Status Address of device [-] 0x Int BIN16 R/W* Code of communication [-] 0x Int BIN16 R/W* speed Serial number of device Hi [-] 0x BCD BIN16 R Serial number of device Lo [-] 0x BCD BIN16 R Version of Firmware Hi [-] 0x BCD BIN16 R Version of Firmware Lo [-] 0x BCD BIN16 R hpa Int*10 PSI Int*1000 Atmospheric pressure inhg mbar oz/in 2 mmhg inh 2 O kpa 0x Int*100 Int*10 Int*10 Int*10 Int*10 Int*100 BIN16 Explanation: * depends on device setting (by User s software) Int*10 register is in format integer*10 R register is designed only for reading W* register is designed for writing, for details see file Description of communication protocols of Txxxx series X register addresses are indexed from zero register 0x31 is physically sent as value 0x30, 0x32 as 0x31 (zero based addressing). Note: In case there is a need for reading of measured values from the device with higher resolution than one decimal, measured values in device are stored also in Float format, which is not directly compatible with IEEE754. R Protocol compatible with Advantech-ADAM standard Control units communicate on master-slave principle in half-duplex operation. Only master can send requests and only addressed device responds. During sending request any of slave devices should respond. During communication data is transferred in ASCII format (in characters). Each Byte is sent as two ASCII characters. Device supports communication speed from 1200Bd to Bd, parameters of communication link are 1 start bit + eight bit data word (LSB first) + 1 stop bit, without parity. Jumper Jumper is located next to connection terminals. If communication protocol compatible with standard Advantech-ADAM is selected, its function is the following: If jumper during switching ON the power is closed, device always communicates with following parameters regardless stored setting in the device: communication speed 9600 Bd, without check sum, device address 00h IE-SNC-T23(4)

8 If jumper during switching ON the power is not closed, device communicates in accordance with stored setting. If jumper is closed during device operation, device temporarily changes its address to 00h, it will communicate in the same communication speed as before closing jumper and will communicate without check sum. After jumper is opened setting of address and check sum is reset in accordance with values stored in the device. Communication speed and check sum are possible to change only if jumper is closed. Jumper closed and button pressed for longer than six seconds causes restoring of manufacturer setting of communication protocol, i.e. sets Modbus RTU communication protocol, device address sets to 01h and communication speed to 9600Bd (after button press there is def message blinking at LCD display. Six seconds later message def stays shown, it means manufacturer setting of communication protocol is done). ARION communication protocol - AMiT company The device supports communication protocol ARiON version For more details see file Description of communication protocols of Txxxx series or Error States of the device Device continuously checks its state during operation. In case error is found LCD displays corresponding error code: Error 0 First line displays Err0. Check sum error of stored setting inside device s memory. This error appears if incorrect writing procedure to device s memory occurred or if damage of calibration data appeared. At this state device does not measure and calculate values. It is a serious error, contact distributor of the device to fix. Error 2 There is a reading Err2 on LCD display. Pressure measurement error occurred. Value read from the device is This state occur if measured pressure value with added correction for altitude is outside of range from 300 hpa to 1350 hpa (from PSI to PSI) or the pressure sensor is damaged. Please check setting of pressure correction for altitude with User s software. Error 4 There is a reading Err4 on LCD display. It is internal device error during pressure sensor initialization. Under this condition device does NOT measure atmospheric pressure. Value read from device is Pressure sensor is probably damaged. It is a serious error, contact distributor of the device. Readings on LCD display hpa, PSI, inhg, Reading next to this symbol is measured pressure or error state of value. If selected pressure unit is mbar or oz/in 2 or mmhg or inh 2 O or kpa, there is shown only value (number) without corresponding pressure unit! symbol 3 near by left display margin Is on if jumper is closed. 8 IE-SNC-T23(4)14-01

9 Technical parameters of the device: RS 485 Interface: Receiver-Input Resistance: Devices on bus: 96 kω Measuring parameters: max. 256 (1/8 Unit Receiver Load) Atmospheric pressure (T5410 only): Unit hpa, mbar PSI mmhg inhg inh 2 O oz/in 2 kpa Range accuracy T=23 C ±1.3 ±0.02 ±1.0 ±0.04 ±0.5 ±0.3 ± T 40 C ±1.5 ±0.02 ±1.1 ±0.04 ±0.6 ±0.3 ±0.15 Else ±2.0 ±0.03 ±1.5 ±0.06 ±0.8 ±0.5 ±0.20 Response time atmospheric pressure 2 : t90 <44s Recommended calibration interval: 1 year Measuring interval and LCD display refresh: 2 s Power: 9 to 30 V dc Consumption: T2314 (RS232) 6 ma T2414 (RS485) max. 0.5W Protection: IP54 Operating conditions: Operating temperature range: -30 to +80 C, over +70 C switch LCD display off Operating relative humidity range: 0 to 100 %RH Outer influence in accordance with EN : normal environment with those specifications: AE1, AN1, AR1, BE1 Working position: communication cable is entering from the top side Electromagnetic compatibility: complies EN Not allowed manipulation It is not allowed to operate the device under conditions other than specified in technical parameters. Devices are not designed for locations with chemically aggressive environment. Do not use the device in an explosive environment. Storing conditions: temperature -30 to +80 C, humidity 0 to 100 %RH without condensation Dimensions: case with electronics 89 x 73 x 37 mm Weight: approximately 150 g Material of the case: ABS 2 There is possible to change response time. For more details see file Description of calibration and adjustment procedure.pdf, which is installed together with Users software. IE-SNC-T23(4)

10 End of operation Device itself (after its life) is necessary to liquidate ecologically! Technical support and service Technical support and service is provided by distributor. For contact see warranty certificate. 10 IE-SNC-T23(4)14-01

11 Appendix A Connection of ELO E06D converter (RS232/RS485) (optionally accessory of the device T2414) The ELO E06D converter is an optional accessory for connection of transmitter/transmitters with RS485 interface to the PC via serial port RS232. Connect connector marked RS232 directly to the PC, connect power to connector marked RS485. Power voltage +6V DC from an external acdc adapter connect to pin 9, 0V connect to pin 5. Also mutually connect pin 2 and pin 7. Link RS485 is connected across pin 3 (A+) and pin 4 (B-). IE-SNC-T23(4)

T2314, T2414. Instruction Manual

T2314, T2414. Instruction Manual Atmospheric pressure transmitter T2314, T2414 with RS232 / RS485 serial output Instruction Manual Instruction Manual Device type Pressure Output Galvanic isolated output T2314 RS232 - T2414 RS485 Device

More information

TRANSDUCER T4311, T4411

TRANSDUCER T4311, T4411 TRANSDUCER T4311, T4411 Programmable temperature transducer for RTD Pt1000 sensor with serial output RS232 and RS485 Instruction manual Instruction Manual for use of transducer: T4311 (RS232), T4411 (RS485)

More information

T3311, T3313, T3411 T7310, T7410. Instruction Manual

T3311, T3313, T3411 T7310, T7410. Instruction Manual Programmable transmitter of temperature, relative humidity and other derived humidity values T3311, T3313, T3411 Programmable transmitter of atmospheric pressure, temperature, relative humidity and other

More information

Programmable transmitter of temperature, relative humidity and other derived humidity values with RS485 serial output Instruction Manual

Programmable transmitter of temperature, relative humidity and other derived humidity values with RS485 serial output Instruction Manual TRANSMITTER T3413, T3417 Programmable transmitter of temperature, relative humidity and other derived humidity values with RS485 serial output Instruction Manual Instruction Manual for use of temperature

More information

T2214. Instruction Manual

T2214. Instruction Manual Programmable atmospheric pressure transmitter T2214 with 0 to 10 V output Instruction Manual Instruction manual for use of T2214 device Device is designed for measurement of atmospheric pressure at hpa,

More information

Programmable indoor transmitter of temperature T0318, T0418

Programmable indoor transmitter of temperature T0318, T0418 Programmable indoor transmitter of temperature T0318, T0418 Programmable indoor transmitter of temperature, relative humidity and other derived humidity values T3318, T3418 Programmable indoor transmitter

More information

T3319, T3419 T7311, T7411. Instruction Manual

T3319, T3419 T7311, T7411. Instruction Manual Programmable transmitter of temperature, relative humidity and other derived humidity values T3319, T3419 Programmable transmitter of atmospheric pressure, temperature, relative humidity and other derived

More information

AT-VLI-102DRS. Manual. ATAL B.V. Ampèrestraat NL-1446 TR PURMEREND. Postbus 783 NL-1440 AT PURMEREND T (+31) F (+31)

AT-VLI-102DRS. Manual. ATAL B.V. Ampèrestraat NL-1446 TR PURMEREND. Postbus 783 NL-1440 AT PURMEREND T (+31) F (+31) AT-VLI-102DRS Manual ATAL B.V. Ampèrestraat 35-37 NL-1446 TR PURMEREND Postbus 783 NL-1440 AT PURMEREND T (+31) 0299 630 610 F (+31) 0299 630 611. E info@atal.nl I www.atal.nl Instruction Manual The transmitters

More information

Programmable temperature transducer from Pt1000 sensor to current loop 4-20 ma Instruction Manual

Programmable temperature transducer from Pt1000 sensor to current loop 4-20 ma Instruction Manual T4111 TRANSDUCER Programmable temperature transducer from Pt1000 sensor to current loop 4-20 ma Instruction Manual Instruction manual for use of T4111 transducer Transducer is designed for temperature

More information

Programmable transmitter of temperature, relative humidity and other derived humidity values with 0 to 10 V outputs Instruction Manual

Programmable transmitter of temperature, relative humidity and other derived humidity values with 0 to 10 V outputs Instruction Manual T0210 TRANSMITTER Programmable transmitter of temperature, relative humidity and other derived humidity values with 0 to 10 V outputs Instruction Manual Instruction manual for use of T0210 transmitter

More information

Temperature, humidity and pressure regulator. with RS485 serial output H0430 H3430 H3431 H3433 H3437 H4431 H7430 H7431. Instruction Manual

Temperature, humidity and pressure regulator. with RS485 serial output H0430 H3430 H3431 H3433 H3437 H4431 H7430 H7431. Instruction Manual Temperature, humidity and pressure regulator with RS485 serial output H0430 H3430 H3431 H3433 H3437 H4431 H7430 H7431 Instruction Manual 1. GENERAL SAFETY RULES...3 2. GENERAL DESCRIPTION...4 3. REGULATOR

More information

TRANSMITTER T3311, T3411

TRANSMITTER T3311, T3411 TRANSMITTER T3311, T3411 Programmable relative humidity and temperature transmitter with serial output RS232 and RS485 With computing of dew point temperature, absolute humidity, specific humidity, mixing

More information

Description of communication protocols of Txxxx series

Description of communication protocols of Txxxx series Description of communication protocols of Txxxx series DESCRIPTION OF COMMUNICATION PROTOCOLS... 3 MODBUS RTU... 3 Supported functions... 3 Jumper and button... 3 Description of supported function... 4

More information

Temperature, humidity and pressure regulator. with RS485 serial output H0430 H3430 H3431 H3433 H3437 H4431 H7430 H7431. Instruction Manual

Temperature, humidity and pressure regulator. with RS485 serial output H0430 H3430 H3431 H3433 H3437 H4431 H7430 H7431. Instruction Manual Temperature, humidity and pressure regulator with RS485 serial output H0430 H3430 H3431 H3433 H3437 H4431 H7430 H7431 Instruction Manual Table of content 1. GENERAL DESCRIPTION... 5 2. REGULATOR MOUNTING

More information

Instruction Manual. T3110 T3110L T3110Ex

Instruction Manual. T3110 T3110L T3110Ex www.cometsystem.cz Instruction Manual T3110 T3110L T3110Ex Programmable transmitter of temperature, relative humidity and other calculated humidity values with 4-20 ma outputs Copyright: COMET System,

More information

Communication protocols description of. Hx4xx and Hx3xx regulators with RS485 and RS232 communication interface

Communication protocols description of. Hx4xx and Hx3xx regulators with RS485 and RS232 communication interface Communication protocols description of Hx4xx and Hx3xx regulators with RS485 and RS232 communication interface Copyright: COMET System, Ltd. It is prohibited to copy and edit this manual and make any changes

More information

Temperature and humidity regulator H3020 H3021 H3023 H3027. Instruction Manual

Temperature and humidity regulator H3020 H3021 H3023 H3027. Instruction Manual Temperature and humidity regulator H3020 H3021 H3023 H3027 Instruction Manual Table of content 1. GENERAL SAFETY RULES... 3 2. GENERAL DESCRIPTION... 4 3. REGULATOR MOUNTING AND CONNECTION... 4 4. DESCRIPTION

More information

Rack mount environment monitor

Rack mount environment monitor Rack mount environment monitor H3531R H4531R H7531R Monitoring of temperature, humidity, barometric pressure and other derived humidity values with Ethernet interface Instruction Manual Table of content

More information

T5540. Programmable transmitter of temperature, relative humidity, CO 2 and other derived humidity values with Ethernet connection T6540

T5540. Programmable transmitter of temperature, relative humidity, CO 2 and other derived humidity values with Ethernet connection T6540 CO 2 concentration transmitter with Ethernet connection T5540 Programmable transmitter of temperature, relative humidity, CO 2 and other derived humidity values with Ethernet connection T6540 Instruction

More information

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 4 OPERATIONAL DIAGRAM 5 WIRING AND

More information

Dual channel temperature logger with two voltage inputs 0-5V Instruction Manual

Dual channel temperature logger with two voltage inputs 0-5V Instruction Manual LOGGER S0541 Dual channel temperature logger with two voltage inputs 0-5V Instruction Manual Instruction Manual for use of S0541 logger Instrument is designed for measurement and record of temperature

More information

AT-VLS-104DE. Manual. ATAL B.V. Ampèrestraat NL-1446 TR PURMEREND. Postbus 783 NL-1440 AT PURMEREND T (+31) F (+31)

AT-VLS-104DE. Manual. ATAL B.V. Ampèrestraat NL-1446 TR PURMEREND. Postbus 783 NL-1440 AT PURMEREND T (+31) F (+31) AT-VLS-104DE Manual ATAL B.V. Ampèrestraat 35-37 NL-1446 TR PURMEREND Postbus 783 NL-1440 AT PURMEREND T (+31) 0299 630 610 F (+31) 0299 630 611 E info@atal.nl I www.atal.nl Inhoud Manual... 1 1. General

More information

Intelligent pressure meter with Ethernet connection T2514

Intelligent pressure meter with Ethernet connection T2514 Intelligent pressure meter with Ethernet connection T2514 Intelligent temperature, relative humidity meter with Ethernet connection With calculation of dew point temperature, absolute humidity, specific

More information

TEMPERATURE AND HUMIDITY TRANSDUCER P18 TYPE USER S MANUAL

TEMPERATURE AND HUMIDITY TRANSDUCER P18 TYPE USER S MANUAL TEMPERATURE AND HUMIDITY TRANSDUCER P18 TYPE USER S MANUAL 1 2 CONTENTS 1. APPLICATION... 5 2. BASIC REQUIREMENTS, OPERATIONAL SAFETY... 5 3. INSTALLATION... 5 3.1. Assembly...5 3.2. Electrical Connections...7

More information

Dual channel temperature logger with two binary inputs and LCD display Instruction Manual

Dual channel temperature logger with two binary inputs and LCD display Instruction Manual LOGGER S0841 Dual channel temperature logger with two binary inputs and LCD display Instruction Manual Instruction Manual for use of S0841 logger Instrument is designed for measurement and record of temperature

More information

Dual channel temperature logger with display Instruction Manual

Dual channel temperature logger with display Instruction Manual LOGGER S0122 Dual channel temperature logger with display Instruction Manual ie-log-s0122-05 Instruction manual for use of temperature logger S0122 Logger is designed for measurement and record of ambient

More information

MU110-6U. Analog output module 6 channel. User guide

MU110-6U. Analog output module 6 channel. User guide MU110-6U Analog output module 6 channel User guide MU110-6U_2016.12_0221_EN All rights reserved Subject to technical changes and misprints akytec GmbH Vahrenwalder Str. 269 A 30179 Hannover Тел.: +49 (0)

More information

Temperature logger with internal sensor Instruction manual

Temperature logger with internal sensor Instruction manual LOGGER R0110 Temperature logger with internal sensor Instruction manual Manual for use of temperature logger R0110 Logger is designed for measurement and record of temperature from built-in internal temperature

More information

RXTP ROOM TEMPERATURE

RXTP ROOM TEMPERATURE ROOM TEMPERATURE CONTROLLER WITH PI CONTROL Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4

More information

Temperature logger with display Instruction Manual

Temperature logger with display Instruction Manual LOGGER S0110 Temperature logger with display Instruction Manual Instruction manual for use of temperature logger S0110 Logger is designed for measurement and record of temperature from built-in internal

More information

IFC 100 Supplementary instructions

IFC 100 Supplementary instructions IFC 100 Supplementary instructions Signal converter for electromagnetic flowmeters Description of Modbus interface Electronic Revision: ER 3.0.xx Modbus version: 1.0.xx KROHNE CONTENTS IFC 100 1 Important

More information

TSA TEMPERATURE SWITCHES 15.13a

TSA TEMPERATURE SWITCHES 15.13a TSA TEMPERATURE SWITCHES 15.13a DESCRIPTION AND APPLICATION These temperature switches are designed for using as two-state controllers (ON/OFF type control). They compare the temperature set-point with

More information

PTU300 Combined Pressure, Humidity and Temperature Transmitter

PTU300 Combined Pressure, Humidity and Temperature Transmitter PTU300 Combined Pressure, Humidity and Temperature Transmitter For Demanding Applications Features Barometric pressure, humidity, and temperature measurement in one transmitter RS-232C serial interface

More information

HPS-M -2 DIFFERENTIAL PRESSURE TRANSMITTER. Mounting and operating instructions

HPS-M -2 DIFFERENTIAL PRESSURE TRANSMITTER. Mounting and operating instructions DIFFERENTIAL PRESSURE Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 5 OPERATIONAL

More information

DXTH DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY. Mounting and operating instructions

DXTH DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY. Mounting and operating instructions DUAL DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL

More information

RXTH DUAL ROOM SENSOR / SWITCH

RXTH DUAL ROOM SENSOR / SWITCH DUAL ROOM SENSOR / SWITCH FOR TEMPERATURE AND RELATIVE HUMIDITY Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE

More information

sensor, which compensates for ageing effects, is highly insensitive to pollution and offers outstanding long term stability.

sensor, which compensates for ageing effects, is highly insensitive to pollution and offers outstanding long term stability. USER S GUIDE EE800 - HVAC Room Transmitter for CO 2, Temperature and Relative Humidity GENERAL EE800 combines CO 2, temperature (T) and relative humidity (RH) measurement in one device with modern design.

More information

Series Pressure Sensor Instruction Sheet

Series Pressure Sensor Instruction Sheet 2018/05/10 Series ure Sensor Instruction Sheet Thank you very much for choosing Delta DPA series pressure sensor. Please read this instruction sheet carefully before using your DPA. Keep this instruction

More information

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS 18 channels for HART / Modbus RTU sensors 2 digital channels 16 math channels 4 relay outputs for alarm or control

More information

DSTHM-2 COMBINED T AND RH DUCT TRANSMITTER. Mounting and operating instructions

DSTHM-2 COMBINED T AND RH DUCT TRANSMITTER. Mounting and operating instructions Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 4 OPERATIONAL DIAGRAMS 5 WIRING AND

More information

TEMPERATURE AND HUMIDITY TRANSDUCER P18(D) TYPE

TEMPERATURE AND HUMIDITY TRANSDUCER P18(D) TYPE TEMPERATURE AND HUMIDITY TRANSDUCER P18(D) TYPE user s manual 1 Contents 1. Application... 5 2. Transducer set... 7 3. Basic requirements, operational safety... 7 4. Installation... 7 4.1. Way of fixing...

More information

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882 1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882 This manual is intended for use in support of installation, commissioning and configuration of the 1/32-DIN Temperature

More information

List of Contents 1. INTRODUCTION DEFINITIONS AND ABBREVIATIONS REFERENCES TECHNICAL DATA GENERAL MODBUS RTU...

List of Contents 1. INTRODUCTION DEFINITIONS AND ABBREVIATIONS REFERENCES TECHNICAL DATA GENERAL MODBUS RTU... MAGX2 RTU User Guide -0- V1.5 23-01-2018 List of Contents 1. INTRODUCTION... 2 1.1 DEFINITIONS AND ABBREVIATIONS... 2 1.2 REFERENCES... 2 2. TECHNICAL DATA... 3 2.1 GENERAL MODBUS RTU... 4 3. COMMISSIONING...

More information

SDM-6RO. Expansion Module 6 relay outputs. Manufactured for

SDM-6RO. Expansion Module 6 relay outputs. Manufactured for Version 1.0 5.02.2014 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have

More information

RS-FS-N01 Wind speed transmitter user's Guide (485type)

RS-FS-N01 Wind speed transmitter user's Guide (485type) RS-FS-N01 Wind speed transmitter user's Guide (485type) Issue: V1.0 1 2 Context 1. Introduction... 4 2. Installation instructions...5 3. Configure the software installation and use... 6 4. Communication

More information

R1M-GH THERMOCOUPLE & DC INPUT MODULE MODEL. Remote I/O R1M Series. (16 points)

R1M-GH THERMOCOUPLE & DC INPUT MODULE MODEL. Remote I/O R1M Series. (16 points) Remote I/O R1M Series THERMOCOUPLE & DC INPUT MODULE (16 points) MODEL MODEL & SUFFIX CODE SELECTION R1MGH2T MODEL Modbus protocol I/O TYPE GH2 : Thermocouple or DC input, 16 points FIELD TERMINAL TYPE

More information

Carbon Monoxide Sensor - ModBus

Carbon Monoxide Sensor - ModBus Introduction The CO Sensor uses an electrochemical sensor to monitor CO level in a range of 0 to 500 ppm and communicates via an RS-485 network configured for ModBus protocol. Before Installation Read

More information

TCNM-ACBB1 Installation Manual

TCNM-ACBB1 Installation Manual The TCNM-ACBB1 is a connection box that can be used as an accessory to facilitate system connections for installation and device replacement of several Banner family reading devices. System cabling is

More information

SDM-8AO. Expansion Module 8 analog outputs. Manufactured for

SDM-8AO. Expansion Module 8 analog outputs. Manufactured for Version 1.0 16.05.2014 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have

More information

isma-b-fcu FCU Hardware User Manual Global Control 5 Sp. z o.o. Warsaw, Poland

isma-b-fcu FCU Hardware User Manual Global Control 5 Sp. z o.o. Warsaw, Poland isma-b-fcu User Manual FCU Hardware Global Control 5 Sp. z o.o. Warsaw, Poland www.gc5.pl Table of contents 1 Introduction 3 1.1 Document change log 3 1.2 Safety rules 3 1.3 Technical specifications 4

More information

Intelligent single channel temperature transducer with Ethernet connection P8511

Intelligent single channel temperature transducer with Ethernet connection P8511 Intelligent single channel temperature transducer with Ethernet connection P8511 Intelligent four channel temperature transducer with Ethernet connection P8541 Intelligent temperature meter with Ethernet

More information

HD B. [ GB ] Precision Barometer

HD B. [ GB ] Precision Barometer HD 9408.3B [ GB ] Precision Barometer [ GB ] [ GB ] Characteristics High accuracy temperature-compensated sensor with excellent stability Wide temperature operating range Various output options available

More information

GE Industrial Sensing. Druck DPI 104. Digital pressure indicator User manual - K394

GE Industrial Sensing. Druck DPI 104. Digital pressure indicator User manual - K394 GE Industrial Sensing Druck DPI 104 Digital pressure indicator User manual - K394 A1.1 A1.2 B1 1 A2 B2 2 3 4 5 6 A1.3 8 7 9 10 A2 13 12 11 14 16 15 K394 Issue 1 Table of Contents Introduction... 1 Safety...

More information

ABB Drives. User s Manual RS-485 Adapter Board FRSA-00

ABB Drives. User s Manual RS-485 Adapter Board FRSA-00 ABB Drives User s Manual RS-485 Adapter Board FRSA-00 Table of Contents 1 INTRODUCTION... 2 1.1 Overview... 2 1.2 Technical Data of RS-485 Link... 2 1.3 RS-485 Bus Topology... 2 2 INSTALLATION... 2 2.1

More information

3-step setting 2. 2-Color Display High-Precision Digital Pressure Switch. ZSE30A(F)/ISE30A Series. Added vacuum range.

3-step setting 2. 2-Color Display High-Precision Digital Pressure Switch. ZSE30A(F)/ISE30A Series. Added vacuum range. 2-Color Display High-Precision Digital Pressure Switch ZSE3A(F)/E3A Series RoHS Can copy to up to 1 switches simultaneously. setting labor Minimizing ZSE3 E3 ZSE4 E4 The settings of the master sensor can

More information

RS485 MODBUS Module 6RO

RS485 MODBUS Module 6RO Version 2.0 12/02/2013 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have

More information

Small distributed I/O module

Small distributed I/O module MLIO Summary Application Function Small distributed I/O module Small I/O module MLIO is a microprocessor-controlled, communiccative module for installation outside the control panel. It is used for topologies

More information

Modbus communication module for TCX2: AEX-MOD

Modbus communication module for TCX2: AEX-MOD Modbus communication module for TCX2: Communication Specification Features S485 2-wire MODBUS standard in accordance with EIA/TIA 485. Slave type of communication Supports up to 127 nodes on one network

More information

RS-FX-N01 wind transmitter user's Guide (485type)

RS-FX-N01 wind transmitter user's Guide (485type) RS-FX-N01 wind transmitter user's Guide (485type) Issue:. V1. 0 1 2 Context 1. Introduction...4 2. Installation instructions... 5 3. Configure the software installation and use...7 4. Communication Protocol...

More information

Modbus Manual Version Modbus Manual for Clean Room Panel CRP5

Modbus Manual Version Modbus Manual for Clean Room Panel CRP5 Page 1 of 42 Modbus Manual Version 1.03 Modbus Manual for Clean Room Panel CRP5 This manual is for persons who will use the Clean Room Panel Modbus protocol. It describes how messages are constructed and

More information

ABB Drives. User s Manual. Modbus Adapter Module RMBA-01

ABB Drives. User s Manual. Modbus Adapter Module RMBA-01 ABB Drives User s Manual Modbus Adapter Module RMBA-01 Modbus Adapter Module RMBA-01 User s Manual 3AFE 64498851 REV A EN EFFECTIVE: 1.3.2002 2002 ABB Oy. All Rights Reserved. Safety instructions Overview

More information

installation Operation ADDRESS product diagram H8030/8031 INSTALLATION GUIDE

installation Operation ADDRESS product diagram H8030/8031 INSTALLATION GUIDE POWER MONITORING INSTALLATION GUIDE H8030/8031 H8030/8031 Modbus Energy Meter Networked kw/kwh Transducer Product Identification Model Max Amps CT Size Enhanced Data Stream Meters H8030-0100- 100 H8030-0300-

More information

RS485 MODBUS Module 8AO

RS485 MODBUS Module 8AO Version 1.3 12/02/2013 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have

More information

Real Time Clock with Temperature Sensor and RS485/Modbus Comunications

Real Time Clock with Temperature Sensor and RS485/Modbus Comunications Real Time Clock with Temperature Sensor and RS485/Modbus Comunications April 29, 2014 Power 8 20 VDC @ less than 100 MA. Battery connect jumper RS485 Bus Load Jumpers Model: RTC-TI2C Page 1 of 6 Features:

More information

with serial RS485/RS232 output

with serial RS485/RS232 output with serial RS485/RS232 output RS485 programmable sensors of temperature, humidity, atmospheric pressure and CO 2 with two-state inputs and relay outputs industry and interior design high quality, accurate

More information

with serial RS485/RS232 output

with serial RS485/RS232 output with serial RS485/RS232 output RS485 programmable sensors of temperature, humidity, atmospheric pressure and CO 2 with two-state inputs and relay outputs industry and interior design high quality, accurate

More information

USER GUIDE PEL 8K / PEL 8K-M

USER GUIDE PEL 8K / PEL 8K-M V2.0.0 (24.10.2014) 1 (7) COMMISSIONING Mounting - The transmitter should be installed above the measuring point to avoid condensation problems. - The duct overpressure is detected by connecting the measuring

More information

Dual differential pressure sensor For ventilation and air-conditioning Model A2G-52

Dual differential pressure sensor For ventilation and air-conditioning Model A2G-52 Pressure Dual differential pressure sensor For ventilation and air-conditioning Model A2G-52 WIKA data sheet PE 88.03 for further approvals see page 5 Applications For monitoring air, non-inflammable and

More information

isma-b-mg-ip User Manual Global Control 5 Sp. z o.o. Poland, Warsaw

isma-b-mg-ip User Manual Global Control 5 Sp. z o.o. Poland, Warsaw isma-b-mg-ip User Manual Global Control 5 Sp. z o.o. Poland, Warsaw www.gc5.pl Table of content 1 Introduction... 4 1.1 Revision history... 5 1.2 Safety rules... 5 1.3 Technical specifications... 6 1.4

More information

DTR.PCE.PRE.SGE.MODBUS(ENG) APLISENS MANUFACTURE OF PRESSURE TRANSMITTERS AND CONTROL INSTRUMENTS. Part 1: USER S MANUAL

DTR.PCE.PRE.SGE.MODBUS(ENG) APLISENS MANUFACTURE OF PRESSURE TRANSMITTERS AND CONTROL INSTRUMENTS. Part 1: USER S MANUAL DTR.PCE.PRE.SGE.MODBUS(ENG) APLISENS MANUFACTURE OF PRESSURE TRANSMITTERS AND CONTROL INSTRUMENTS Part 1: USER S MANUAL Part 2: Selected issues concerning the operation of transmitters using Modbus Configurator

More information

WSK INTELLIGENT TEMPERATURE AND HUMIDITY CONTROLLER USER MANUAL

WSK INTELLIGENT TEMPERATURE AND HUMIDITY CONTROLLER USER MANUAL WSK INTELLIGENT TEMPERATURE AND HUMIDITY CONTROLLER USER MANUAL WSK INTELLIGENT TEMPERATURE AND HUMIDITY CONTROLLER USER MANUAL v 1.0 Thanks for choosing the Intelligent temperature and humidity controller

More information

HARDENED ROOM SENSOR USER MANUAL SAD120 CPO55 E 1

HARDENED ROOM SENSOR USER MANUAL SAD120 CPO55 E 1 HARDENED ROOM SENSOR USER MANUAL SAD120 CPO55 LOREME 12, rue des Potiers d'etain Actipole BORNY - B.P. 35014-57071 METZ CEDEX 3 Phone 03.87.76.32.51 Contact : Commercial@Loreme.fr - Technique@Loreme.fr

More information

mbc082 Bus Converter

mbc082 Bus Converter BUS CONVERTER RS485 TO 1-WIRE BUS mbc082 mbc082 Bus Converter Document. 10910, Revision - February 2007 2007 CMC Industrial Electronics Ltd. This page intentionally left blank. mbc082 Bus Converter Technical

More information

Environdata FA ma Converter Guide

Environdata FA ma Converter Guide FA12 4 20 ma Converter Guide REV 14 th July 2015 Material in this Handbook is copyright. All rights reserved by the publishers. Weather Stations Pty. Ltd., 42-44 Percy Street, Warwick, Queensland, AUSTRALIA,

More information

SMI2. RS485 Display. User guide

SMI2. RS485 Display. User guide EN SMI2 RS485 Display User guide SMI2_2016.07_0134_EN All rights reserved Subject to technical changes and misprints Contents 1 Safety guidelines... 2 2 Intended use... 3 3 Specification... 4 4 Functional

More information

Output Signal Active Note DC V. Electrical Data Power Supply DC V, ±10%, 1.4 W

Output Signal Active Note DC V. Electrical Data Power Supply DC V, ±10%, 1.4 W Differential Pressure Sensor (Air) Differential pressure transmitter with 8 selectable ranges 0 to 5/10 V, 4 to 20 ma outputs and Modbus functionality. NEMA 4X / IP65 rated enclosure. For monitoring the

More information

The IQ300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

The IQ300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications. IQ300 Wall Mount Load Cell Indicator Data sheet English 1.01 Introduction The IQ300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications. The high

More information

Gateway BACnet IP/MS-TP slave KNX TP Code: EK-BJ1-TP-IP / EK-BJ1-TP-MSTP

Gateway BACnet IP/MS-TP slave KNX TP Code: EK-BJ1-TP-IP / EK-BJ1-TP-MSTP writing single and multiple -bit registers (Coil and Status) as well as 6-bit registers (Holding and Input). It is also possible to read and write multiple registers containing -bit floating point values

More information

USER GUIDE PEL / PEL-M

USER GUIDE PEL / PEL-M V2.0.0 (05.09.2014) 1 (6) COMMISSIONING Mounting - The transmitter should be installed above the measuring point to avoid condensation problems. - The duct overpressure is detected by connecting the measuring

More information

GFK-2415A March Type of sensor connection

GFK-2415A March Type of sensor connection VersaMax IP Expansion Module has four analog differential inputs that can be configured as current or voltage inputs. It connects to a local bus that is interfaced to a Profibus-DP / PROFINET network by

More information

EE160 - Humidity and Temperature Transmitter for HVAC Applications

EE160 - Humidity and Temperature Transmitter for HVAC Applications USER S GUIDE EE160 - Humidity and Temperature Transmitter for HVAC Applications GENERAL The EE160 transmitter, available for wall or duct mounting, is designed for the measurement of humidity and temperature

More information

MPS-32. Pressure Sensors MPS-32 2-Color Panel Mount. Features. Green Display. MPS-32 Programming Options

MPS-32. Pressure Sensors MPS-32 2-Color Panel Mount. Features. Green Display. MPS-32 Programming Options Features MPS- Green Display MPS-VN-PC ure Sensors Features ure Ranges: Vacuum ure 0 to -0 inhg Positive ure 0 to 5 PSI Sensor : NPN or PNP Open Collector Transistor, 0VDC, 5mA Optional Analog, to 0mA Optional

More information

Hydrostatic filling level sensor HFB C4 / R / MD

Hydrostatic filling level sensor HFB C4 / R / MD Hydrostatic filling level sensor HFB C4 / R / MD Pressure measuring range 0-0.5 bar Voltage supply 18 30 V DC Features Filling level detection through measuring the hydrostatic medium pressure by means

More information

Copyright Extract from Conditions of Sale Safety Warning

Copyright Extract from Conditions of Sale Safety Warning KD420 User Manual Copyright 2004-2013 KK Systems Ltd. No reproduction of any part of this document, in any form, is allowed without prior written permission from KKSystems Ltd. All other copyrights and

More information

IntesisBox PA-AW-MBS-1 v.2.0

IntesisBox PA-AW-MBS-1 v.2.0 IntesisBox PA-AW-MBS-1 v.2.0 Modbus RTU (EIA485) Interface for Panasonic Aquarea series. User Manual Issue Date: 08/2014 r2.0 Order Code: PA-AW-MBS-1: Modbus RTU Interface for Panasonic Aquarea series

More information

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description I/O extension module, eight digital transistor outputs Data sheet 105364_en_00 PHOENIX CONTACT 2013-03-26 1 Description The I/O extension module can be used in conjunction with Radioline wireless modules

More information

FEATURES DESCRIPTION FEATURES

FEATURES DESCRIPTION FEATURES FEATURES Two High Speed Counters Two Pulse Train Outputs Two Pulse Width Modulation Outputs 24 Sinking or Sourcing Inputs 16 Outputs 1 RS232 Port 2 RS485 Ports Supports Modbus RTU Protocol Communicate

More information

GmbH, Stettiner Str. 38, D Paderborn

GmbH, Stettiner Str. 38, D Paderborn AnDi 1 to AnDi 4 A/D Converter for M-Bus (Valid from M-Bus generation: $31) Art. no. MB AnDi 1 Art. no. MB AnDi 2 Art. no. MB AnDi 3 Art. no. MB AnDi 4 1 channel A/D converter for M-Bus 2 channel A/D converter

More information

Enercept H8035/H8036 Modbus Energy Meter Networked kw/kwh Transducers

Enercept H8035/H8036 Modbus Energy Meter Networked kw/kwh Transducers POWER MONITORING INSTALLATION GUIDE Enercept H8035/H8036 Modbus Energy Meter Networked kw/kwh Transducers US Patent No. 6,373,238 Installer's Specifications Input Voltage 208 to 480 VAC Number of Phases

More information

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26 phone: / , fax: / ,

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26 phone: / , fax: / , H55.0.31.6C-04 Operating Manual Vacuum- / Baro- / Manometer from Version 1.1 GDH 200-14 GREISINGER electronic GmbH D - 93128 Regenstauf, Hans-Sachs-Straße 26 phone: +49 9402 / 9383-0, fax: +49 9402 / 9383-33,

More information

GMH to 1300 mbar absolute Version 4.7

GMH to 1300 mbar absolute Version 4.7 H31.0.03.6C-09 User s Manual Handheld Digital Vacuum- and Barometer GMH3160-12 0 to 1300 absolute Version 4.7 H31.0.03.6C-09 User s Manual GMH3160-12 page 2 CONTENTS 1 GENERAL...2 1.1 SAFETY REQUIREMENTS...2

More information

BAPI-Stat 4MB Modbus Temp or Temp/Humidity Sensor

BAPI-Stat 4MB Modbus Temp or Temp/Humidity Sensor BAPI-Stat 4MB Modbus Temp or Temp/Humidity Sensor 34350_ins_BS4_modbus Product Identification and Overview The BAPI-Stat 4MB Modbus room temperature or temperature/ humidity sensor is available with optional

More information

TOXALERT MODEL AIR 2000

TOXALERT MODEL AIR 2000 TOXALERT MODEL AIR 2000 NOTE: Toxalert s Model GVU-CO 2 Sensor is the same as the Air2000R. Microprocessor-based, Infrared Environmental CO 2 Sensor OPERATOR S MANUAL TOXALERT TM INTERNATIONAL INC. P.O.

More information

2562 QUICK START GUIDE

2562 QUICK START GUIDE 2562 QUICK START GUIDE CTI P/Ns: 2562 Quick Start Guide: 062-00348-010 2562 Installation and Operation Guide: 062-00332-011 Summary: The 2562 is designed to translate a digital word from the programmable

More information

DWYER INSTRUMENTS, INC. Series AVUL Air Velocity Transmitter. Specifications - Installation and Operating Instructions.

DWYER INSTRUMENTS, INC. Series AVUL Air Velocity Transmitter. Specifications - Installation and Operating Instructions. Series AVUL Air Velocity Transmitter Specifications - Installation and Operating Instructions Bulletin P-AVUL 3-49/64 [95.71] 2-43/64 [67.92] 1/2 NPS 3-3/16 [80.81] 1-19/32 [40.59] 31/32 24.58 3-33/64

More information

Tango. alpha nea. Thermometers and controllers with digital communication - Series AM

Tango. alpha nea. Thermometers and controllers with digital communication - Series AM Installed in Tango (standard) or alpha nea frames Modbus RTU communication over RS485 line Wide range of power supply Control knob for correction setting Can be installed in a multifunction frame Tango

More information

MODBUS RTU I/O Expansion Modules - Models C267, C277, and C287. Installation and Operations Manual Section 50

MODBUS RTU I/O Expansion Modules - Models C267, C277, and C287. Installation and Operations Manual Section 50 MODBUS RTU I/O Expansion Modules - Models C267, C277, and C287 Installation and Operations Manual 00-02-0651 09-01-09 Section 50 In order to consistently bring you the highest quality, full featured products,

More information

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description I/O extension module with 8 digital inputs or 2 pulse inputs INTERFACE Data sheet 0483_en_00 PHOENIX CONTACT 203-04-05 Description The I/O extension module can be used in conjunction with Radioline wireless

More information

ENERCEPT H8035/H8036 DANGER NOTICE CAUTION. Networked Power Transducer (Modbus RTU) INSTALLATION GUIDE QUICK INSTALL TABLE OF CONTENTS

ENERCEPT H8035/H8036 DANGER NOTICE CAUTION. Networked Power Transducer (Modbus RTU) INSTALLATION GUIDE QUICK INSTALL TABLE OF CONTENTS POWER MONITORING ENERCEPT Networked Power Transducer (Modbus RTU) DANGER US Patent No. 6,373,238 HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in

More information

RS485 MODBUS Module 16I-M

RS485 MODBUS Module 16I-M Version 2.0 12/02/2013 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have

More information