ANT CNTR DC ALRM LNB RX DC ALRM +18V OFF
|
|
- Harriet Little
- 6 years ago
- Views:
Transcription
1 Instruction Manual Model Power Supply July 2012, Rev. B MODEL 2082 POWER SUPPLY CROSS TECHNOLOGIES INC. PRIMARY PWR AC BUC +48V AUX BUC TX SELECT 48V +18V/48V LNB RX +18V ANT CNTR +29V AC 18V Data, drawings, and other material contained herein are proprietary to Cross Technologies, Inc., but may be reproduced or duplicated without the prior permission of Cross Technologies, Inc. for purposes of operating the equipment. When ordering parts from Cross Technologies, Inc., be sure to include the equipment model number, equipment serial number, and a description of the part. CROSS TECHNOLOGIES, INC Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free WEB: info@crosstechnologies.com
2 INSTRUCTI MANUAL MODEL Power Supply TABLE OF CTENTS PAGE Warranty General Equipment Description Technical Characteristics Installation Mechanical Rear Inputs, Outputs and Indicators Front Controls and Indicators Operation Environmental Use Information 10 WARRANTY - The following warranty applies to all Cross Technologies, Inc. products. All Cross Technologies, Inc. products are warranted against defective materials and workmanship for a period of one year after shipment to customer. Cross Technologies, Inc. s obligation under this warranty is limited to repairing or, at Cross Technologies, Inc. s option, replacing parts, subassemblies, or entire assemblies. Cross Technologies, Inc. shall not be liable for any special, indirect, or consequential damages. This warranty does not cover parts or equipment which have been subject to misuse, negligence, or accident by the customer during use. All shipping costs for warranty repairs will be prepaid by the customer. There are not other warranties, express or implied, except as stated herein. CROSS TECHNOLOGIES, INC Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free WEB info@crosstechnologies.com Manual_Rev.B Page 2 07/26/12
3 MODEL Power Supply 1.0 General 1.1 Equipment Description The Power Supply is a voltage Power Supply used for BUC and LNB applications. Power is inserted via two L-Band loop-throughs and a +48 V, 8A output is provided on the BUC output. The two L-Band loop-throughs insertion, a +18V, 1A output is provided on the Antenna LNB input and either 3A or 5A is provided on the Antenna AUX BUC TX output. The unit facilitates the installation of a TracStar Antenna Controller and provides the +29V 150W needed with all of the TracStar connectors accessible through the rear panel. Front panel locking toggle switches allow the user to independently disable the power on either L-Band loop-through, the BUC output and the TracStar antenna controller. The AUX BUC TX and BUC output are interlocked to prevent both outputs from being simultaneously enabled. The user is also able to select +18V or +48V insertion on the AUX BUC TX loop-through. A 500mA AUX output is provided for user devices. Primary power is either 19-72V or VAC. If both primary power sources are connected the user can select which will be enabled and the other source will be put in a standby mode and serve as a backup power source. If only one primary source is connected, the Power Supply will use the available power source regardless of the selected primary power source switch position. Each power source is fused using rear panel mount fuse holders. Front panel LEDs indicate AC or primary power (green), and Standby (yellow). output indications are provided for all four outputs (three outputs and the TracStar antenna controller). Front panel LEDs (green) and rear panel LEDs (yellow) indicate the presence of voltage on LNB, BUC, Aux BUC and the TracStar. Front panel LEDs (yellow) indicate the output is in a Standby condition. Front panel LEDs (red) indicate an Alarm condition which is the result of a blown or missing fuse. The alarm condition will only occur if the output is enabled. Front panel test points are provided for each of the four output voltages and ground. All loop-through connectors are TNC female. The unit is housed in a RU x 3.50 High x Deep chassis. MODEL 2082 POWER SUPPLY CROSS TECHNOLOGIES INC. PRIMARY PWR AC BUC +48V AUX BUC TX SELECT 48V +18V/48V LNB RX +18V ANT CNTR +29V AC 18V FRT PANEL AUX +48V 1/2 AMP MAX ANT MOD PC ICC BUC +48 V 8A MAX V IN 60A DO NOT OBSTRUCT AIR INTAKE VAC 15A MODEM ANTENNA RX TX LNB AUX BUC TX ANT CTR LNB RX AUX BUC TX BUC DS1 FUSE DS2 FUSE DS3 FUSE DS4 FUSE REAR PANEL FIGURE 1.1 Front and Rear Panels Manual_Rev.B Page 3 07/26/12
4 1.1 Equipment Description (continued) AUX +48 V 1/2A MAX V INPUT +48 V BUC +48 MAX AUX BUC TX (Antenna) LOGIC & CTROL TX (Modem) +18 V LNB (Antenna) VAC INPUT AC PS +48 V RX (Modem) +29 V ANTENNA CTROLLER Block Diagram FIGURE Power Supply Block Diagram Manual_Rev.B Page 4 07/26/12
5 1.2 Technical Characteristics TABLE Power Supply Equipment Specifications* L-Band Insertion RF Input/Outout Characteristics Impedance/Return Loss 50Ω / 10 db minimum Frequency 950 to 2150 MHz and 10 MHz Insertion Loss 1 ± 0.5 db (L-Band); 1 db max. (10 MHz) Frequency Response ± 1.0 db, MHz; ± 0.5 db, 36 MHz BW Output Power Characteristics Voltage/Current, BUC AUX +48 V, 5 A, max. OR +18 V, 3 A selectable Voltage/Current, LNB +18 V, 1 A, max. Voltage/Current, BUC +48 V, 8 A, max. Voltage/Current, TracStar +29 V, 5 A, max. Voltage/Current AUX +48 V +48 V, 500 ma max. Load Regulation ± 5% Primary Input Power Characteristics Voltage/Current, Voltage/Current, AC Connectors Input AC Input BUC TracStar AUX +48 V V, 60A, max. 1200W VAC. 15A, max., Hz, 1200Q Barrier Strip, M5 screw, 3-10 AWG CU wire Schurter with cord Retention TBD (Circular Bayonet 2-pin with sockets) Refer to TracStar documentation Molex 2-pin receptacle with sockets (mating connector: (mating connector: Molex , with pin ). Other RF Connectors (Call for other connectors) Size Power Weight TNC, 50 Ω (female) 19 inch, 1 RU, 3.50 X 12.0 D** V, 1200W OR VAC Hz. 1200W 20 lbs. *10 C to 40 C; Specifications subject to change without notice. **Does not account for connector protrusion TracStar Systems, Inc All Rights Reserved Manual_Rev.B Page 5 07/26/12
6 2.0 Installation 2.1 Mechanical The consists of one RF PCB housed in a 19.0, 2 RU, X 3.50 high X deep chassis. Six front panel locking toggle switches allow the user to disable the power outputs and insertion on all outputs. The can be secured to a rack using the 4 holes on the front panel and six side screws for mounting or using rack slides. Figure 2.0 shows how the is assembled. POWER SUPPLY 19-72V and VAC FIGURE 2.1 Mechanical Assembly Manual_Rev.B Page 6 07/26/12
7 2.2 Rear Panel Inputs, Outputs, and Indicators Figure 2.2 shows the input and output signals and indicators on the rear panel TracStar I/05 refer to TracStar documentation. INPUT Barrier Strip MOLEX 2 pin connector EXHAUST VENT LNB AUX BUC AUX +48V 1/2 AMP MAX ANT MOD PC ICC BUC +48 V 8A MAX V IN 60A DO NOT OBSTRUCT AIR INTAKE VAC 15A MODEM ANTENNA RX TX LNB AUX BUC TX ANT CTR LNB RX AUX BUC TX BUC DS1 FUSE DS2 FUSE DS3 FUSE DS4 FUSE COOLING FANS Intake fans that provide cooling to the power supplies. AC INPUT Schurter w/cord retention +29V FUSE (5A fast-blo) and indicator +18V FUSE (1A fast-blo) and indicator +18/48V FUSE (5A fast-blo) and indicator +48V FUSE (8A fast-blo) and indicator EXHAUST VENTS Do Not Block FIGURE 2.2 Rear Panel Outputs 2.3 Front Panel Controls and Indicators Figure 2.3 shows the front panel controls and indicators. MODEL 2082 POWER SUPPLY CROSS TECHNOLOGIES INC. PRIMARY PWR AC BUC +48V AUX BUC TX SELECT 48V +18V/48V LNB RX +18V ANT CNTR +29V AC 18V LOCKING TOGGLE SWITCH FP SPST Locking Toggle switch (6 places) AC/ Select BUC/ On/Off Status AUX / BUC Loop-through On/Off/Status LNB Loop-through On/Off/Status TracStar On/Off/Status FIGURE 2.3 Front Panel Controls and Indicators Manual_Rev.B Page 7 07/26/12
8 2.4 Installation / Operation Power Supply 1. Connect L-Band Modem to appropriate TX and RX TNC connectors. 2. Connect Antenna to the LNB TNC and the BUC TNC if using the Aux TX power. 3. Connect the BUC power to the Ext BUC power connector if using the BUC Output terminal block (18-12 AWG depending on length). 4. Ensure the AUX BUC Select is in the desired position if using the Aux BUC TX power (either +48V or +18V). 5. Connect the Aux +48V output as desired ensuring not to exceed the 500mA output (mating connector Molex w/pins ). 6. Make sure that all of the on/off switches are in the off position (switches must be pulled out in order to change positions). 7. Connect desired primary power to the input terminal block using a minimum of 8 AWG wire for short distances and 6 AWG or larger (3 AWG max.) for input cables longer than 2 meters. The power source must be capable of supply 60A surge and 45A continuous power. 8. Connect the AC input using the supplied AC power cord and move the locking mechanism to secure the connector. The AC power source must be able to supply a minimum of 15A continuous current. 9. Select either AC or primary power on the front panel. 10. Apply primary power and verify that the shows a standby condition on all outputs and the desired primary power source is indicated. 11. Enable power outputs as desired. Note: The BUC output and Aux BUC TX outputs are interlocked and cannot both be enabled at the same time. Notes: 1. Connecting or disconnecting rear panel connections while power is enabled will result in damage to the connectors and possibly the power supply. 2. An alarm indication on the front panel when power is enabled on any of the four outputs indicates a missing or blown rear panel fuse. 3. The Aux 500mA has a reset able fuse that will open when the output current is exceeded. Should this occur, remove the load from the output and wait five minutes for the fuse to reset. Correct the overloading fault and reconnect the output Manual_Rev.B Page 8 07/26/12
9 3.0 Environmental Use Information A. Rack-Mounting - To mount this equipment in a rack, please refer to the installation instructions located in the user manual furnished by the manufacturer of your equipment rack. The supply must be braced from the rear as well as the front panel. power B. Mechanical Loading - Mounting of equipment in a rack should be such that a hazardous condition does not exist due to uneven weight distribution. C. Elevated Operating Ambient Temperature - If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack may be greater than room ambient temperature. Therefore, consideration should be given to Tmra. D. Reduced Air Flow - Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised. Additional space between units may be required. E. Circuit Overloading - Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of circuits could have on over current protection and supply wiring. Appropriate consideration of equipment name plate rating should be used when addressing this concern. F. Reliable Earthing - Reliable earthing of rack-mounted equipment should be maintained. Particular attention should be given to supply connections other than direct connection to the Branch (use of power strips). G. Top Cover - There are no serviceable parts inside the product so, the Top Cover should not be removed. If the Top Cover is removed the ground strap and associated screw MUST BE REINSTALLED prior to Top Cover screw replacement. FAILURE TO DO this may cause INGRESS and/or EGRESS emission problems Manual_Rev.B Page 9 07/26/12
10 CROSS TECHNOLOGIES, INC Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free WEB Printed in USA Manual_Rev.B Page 10 07/26/12
STATUS Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free
Instruction Manual Model 1582-45L Data Switch September 2010, Rev A REMOTE LOCAL SWITCH STATUS SELECT REMOTE LOCAL LOCAL SELECT CHANNEL SELECT POWER MODEL 1582 SWITCH CROSS TECHNOLOGIES, INC. Data, drawings,
More informationMONITOR Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free
Instruction Manual Model 1584-25 Splitter December 2009 Rev B MITOR 1 MITOR 2 A B MODEL 1584 DIVIDER CROSS TECHNOLOGIES C. Data, drawings, and other material contained herein are proprietary to Cross Technologies,
More informationPOWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free
Instruction Manual Model 1582-10M Protection Switch January 2009 Rev O ALARMS MENU OUTPUT = CH1 AUTO POWER 1 2 MODEL 1582 SWITCH CROSS TECHNOLOGIES INC. CH1 CH2 REMOTE EXECUTE Data, drawings, and other
More informationInstruction Manual Model Block Translator
Instruction Manual Model 2083-1010 Block Translator May 2018, Rev. 0 1250>1200 G=-10.0 REF = AUTO - I MENU MODEL 2083 TRANSLATOR CROSS TECHNOLOGIES INC. REMOTE POWER ALARM EXECUTE Data, drawings, and other
More informationThe power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.
The power behind competitiveness Delta Infrasuite Power Management Power Distribution Unit User Manual www.deltapowersolutions.com Save This Manual This manual contains important instructions and warnings
More informationModel L 10MHz Frequency Source, Switch, Inserter
Instruction Manual Model 2099-1004-21L 10MHz Frequency Source, Switch, Inserter April 2011, ev. O EXT ALAMS MENU EF MODE INSET LVL OUT LVL AUTO-E +3dBm +12dBm AUTO 1 2.5A EFEENCE SWITCH POWE 1 2 MODEL
More informationiconverter 2-Module Power Chassis
iconverter 2-Module Power Chassis User Manual 38 Tesla, Irvine, CA 92618 USA Phone: (949) 250-6510; Fax: (949) 250-6514 Page 1 Warning The operating description in this Instruction Manual is for use by
More informationAutomated Tuner System Power Distribution Hub
User Guide Automated Tuner System Power Distribution Hub Model MT1020B MT1020-340 (Rev B) 12/11 User Guide Automated Tuner System Power Distribution Hub Model MT1020B 2900 Inland Empire Boulevard Ontario,
More informationLVN5200A-R2, rev. 1, Hardware Installation Guide
LVN5200A-R2 LVN5250A-R2 LVN5200A-R2, rev. 1, Hardware Installation Guide Customer Support Information Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500) FREE technical support
More informationOmnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual
Omnitron Systems Technology, Inc. 1 iconverter 19-Module Managed Power Chassis User s Manual 27 Mauchly, #201, Irvine, CA 92618 Phone: (949) 250-6510; Fax: (949) 250-6514 2 Omnitron Systems Technology,
More informationHP UPS R/T3000 ERM. Overview. Precautions. Installation Instructions
HP UPS R/T3000 ERM Installation Instructions Overview The ERM consists of two battery packs in a 2U chassis. The ERM connects directly to a UPS R/T3000 or to another ERM. Up to two ERM units can be connected.
More informationHP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions
HP UPS R/T3000 G2 Installation Instructions Overview The HP UPS R/T3000 G2 features a 2U rack-mount with convertible tower design and offers power protection for loads up to a maximum of 3300 VA/3000 W
More informationZonit μats TM Users Guide μats1-lv Version 1.2
Zonit μats TM Users Guide μats1-lv Version 1.2 Table of Contents Product Overview...2 Pre-Installation Considerations...2 Product Features...3 Installation...4 Optional Accessories...4 μats TM Operational
More informationTRC-190 User s Manual
User s Manual Edition 3.2, May 2017 www.moxa.com/product 2017 Moxa Inc. All rights reserved. User s Manual The software described in this manual is furnished under a license agreement and may be used only
More informationTRC-190 User s Manual
First Edition, November 2008 www.moxa.com/product 2008 Moxa Inc. All rights reserved. Reproduction without permission is prohibited. The software described in this manual is furnished under a license agreement
More informationInstallation and Getting Started Guide. HP ProCurve 600/610 External Power Supplies. PoE. Power over Ethernet Devices
Installation and Getting Started Guide HP ProCurve 600/610 External Supplies www.hp.com/go/hpprocurve PoE over Ethernet Devices HP ProCurve 600/610 External Supplies Installation and Getting Started Guide
More informationNT1-220 Rack. Installation Instructions. Specifications. Contents of Shipping Box. Important Safety Instructions. NT1-220 Rack
The NT1-220 Rack is designed to be used in conjunction with Tone Commander NT1U-220TC ISDN Network Terminations. A maximum of twelve NT1 units can be used in each rack. NT1-220 Rack Installation Instructions
More informationDell Networking S4810 Open Networking (ON) Getting Started Guide
Dell Networking S4810 Open Networking (ON) Getting Started Guide Regulatory Model: S4810 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your
More informationRF0250 RF1100 RF1200 RF1300 RF1600
RF0250 RF1100 RF1200 RF1300 RF1600 Power Amplifier User Manual Issue 5 September 2017 LAPLACE INSTRUMENTS LTD Page 1 Page 2 Caution This unit produces high RF-power. It must be assured that maximum radiation
More informationInstallation Instructions Model LFMWLT450, Class 1 Series AC-DC Power Supply
AC INPUT : 100-240 VAC, 6.2 A 47-63 Hz SAFETY APPROVALS: ANSI/AAMI ES60601-1 (2005 + C1:09 + A2:10) CAN/CSA-C22.2 No. 60601-1 (2008) IEC 60601-1(ed.3) EN 60601-1:2006;A11 (Input selection is automatic;
More informationQUICKSTART INSTALLATION INSTRUCTIONS
WEGENER i8640 DIGITAL AUDIO SERVER QUICKSTART INSTALLATION INSTRUCTIONS This satellite receiver has been provided for the reception of MRN, WestwoodOne or Compass Sports. Once installed, please contact
More informationRE-82 RACK MOUNT DIMMER OWNERS MANUAL. 8 X 2400Watts. Revision /29/2007
RE-82 RACK MOUNT DIMMER 8 X 2400Watts OWNERS MANUAL Revision 2.4 11/29/2007 Page 2 of 8 RE-82 CONTROL PANEL DESCRIPTION The RE-82 is an 8 channel dimmer with a maximum capacity of 2,400 watts per channel
More informationOPTICAL HEADEND PLATFORM OTOHP-CH 3RU CHASSIS OTOHP-PS POWER SUPPLY MODULE OTOHP-BP BLANK PANEL INSTRUCTION MANUAL
OPTICAL HEADEND PLATFORM OTOHP-CH 3RU CHASSIS OTOHP-PS POWER SUPPLY MODULE OTOHP-BP BLANK PANEL INSTRUCTION MANUAL Phone: (209) 586-1022 (800) 545-1022 Fax: (209) 586-1026 OTOHP-CH Rev. X1 E-Mail: salessupport@olsontech.com
More informationBroadband Automatic Disconnect Switch. User Manual
Reset/Test Primary/ Primary Broadband Automatic Disconnect Switch User Manual Local Power Remote Pwer Local 63V Fault Secondary Select Secondary 220V Normal 990-1929 09/2004 Introduction Introduction
More informationInnovative Circuit Technology Ltd.
Innovative Circuit Technology Ltd. Pro Series DC Power Supply INSTRUCTION MANUAL 855-343-001 Models: ICT690-12S/ICT690-12SB ICT690-24S/ICT690-24SB ICT690-48S/ICT690-48SB ICT1190-12S/ICT1190-12SB ICT1190-24S/ICT1190-24SB
More informationPagePac PAGEPAC PLUS ZONE EXPANSION UNIT V
PagePac Issue 3 by PAGEPAC PLUS ZONE EXPANSION UNIT V-5335100 INTRODUCTION The Zone Expansion Unit (ZEU) provides up to 16 zones of audio output (including talkback), contact closure outputs or inputs.
More informationNT1B-300 Rack Installation Instructions
The NT1B-300 Rack houses 24 Tone Commander NT1B-300TC ISDN Network Terminations in a 19 rack, 23 rack, or wall mount configuration. The rack is also compatible with Lucent NT1B-300 NT1s. The rack supplies
More informationOPR Power Series AC to DC POWER SUPPLY SERIES WITH REMOTE MANAGEMENT AND ALARM SYSTEMS. Model Nos. OPR065-48S / OPR065-48R. Manual
OPR Power Series AC to DC POWER SUPPLY SERIES WITH REMOTE MANAGEMENT AND ALARM SYSTEMS Model Nos. OPR065-48S / OPR065-48R Manual Revision F July 2009 Optimal Power Supplies LLC www.optimal-power.com i
More informationS-Band Redundant LNA Systems
S-Band Redundant LNA Systems LRS-1000 Series Introduction Redundant LNA systems minimize system downtime due to LNA failure by providing a spare LNA and an automatic means of switching to the spare upon
More informationINSTRUCTION MANUAL RA 19-5B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES
INSTRUCTION MANUAL RA 19-5B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES KEPCO INC. An ISO 9001 Company. MODEL RA 19-5B RACK ADAPTER ORDER NO. REV. NO. IMPORTANT NOTES: 1) This manual
More informationKramer Electronics, Ltd. USER MANUAL. Model: VM-4HDCP. 1:4 DVI Distributor
Kramer Electronics, Ltd. USER MANUAL Model: VM-4HDCP 1:4 DVI Distributor Contents Contents 1 Introduction 1 2 Getting Started 1 2.1 Quick Start 2 3 Overview 3 3.1 About HDCP 3 3.2 Defining EDID 4 3.3 Recommendations
More informationClearCube F6151 Media Converter Chassis System with 10/100BaseTX to 100BaseFX Converter
ClearCube FO-065-1200 series 12-Port Media Converter ClearCube F6151 Media Converter Chassis System with 10/100BaseTX to 100BaseFX Converter User s Manual 1 ClearCube Connectivity Systems F6151 Media Converter
More informationREDUNDANT POWER SUPPLY SYSTEM FOR NETGEAR RPS CAPABLE ETHERNET SWITCHES
REDUNDANT POWER SUPPLY SYSTEM FOR NETGEAR RPS CAPABLE ETHERNET SWITCHES MODEL NO. OPN300-48SN Single-Port 48V DC Output RPS System Manual Revision E May 2009 Optimal Power Supplies LLC www.optimal-power.com
More informationModel x-Series
Instruction Manual Model 2082-14x-Series edundant Unit Controllers May 2018, ev. E POWE 1 2 ALAM STDBY ONLINE 1 STATUS 2 3 MODE AUTO MANUAL LOCAL EMOTE UNIT 1 UNIT 2 UNIT 3 STATUS 450 470 380 PATH 11 22
More informationINSTRUCTION MANUAL RA 19-6B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES
INSTRUCTION MANUAL RA 19-6B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES KEPCO INC. An ISO 9001 Company. MODEL RA 19-6B RACK ADAPTER ORDER NO. REV. NO. IMPORTANT NOTES: 1) This manual
More informationINSTRUCTION MANUAL RA 19-4B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES
INSTRUCTION MANUAL RA 19-4B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES KEPCO INC. An ISO 9001 Company. MODEL RA 19-4B RACK ADAPTER ORDER NO. REV. NO. IMPORTANT NOTES: 1) This manual
More informationimaging Series Quartet Guide to Installation and Operation M
imaging Series Quartet Guide to Installation and Operation M028-9900-300 imaging Housing Frame Copyright 1999 Miranda Technologies Inc. Specifications may be subject to change. Printed in Canada June 1999
More informationR & D SPECIALTIES SERIES 100 RO CONTROLLER USERS MANUAL. 2004, by R & D Specialties, Inc. All Rights Reserved.
R & D SPECIALTIES 2004, by R & D Specialties, Inc. All Rights Reserved. No part of this document may be copied or reproduced in any form or by any means without the prior written permission of R & D Specialties.
More informationGT- HE910-EUD. Product description Rev. 8 21/02/ Overview
GT- HE910-EUD Product description Rev. 8 21/02/2013 1. Overview The GT-HE910-EUD is a complete Cellular Terminal solution for GSM/UMTS applications. Based on Telit HE910-EUD module. 1 Hardware Interface
More informationModel HM-535 Power Supply Installation and Service Instructions
Model HM-535 Power Supply Installation and Service Instructions 430-535 0104 2004 Heritage MedCall, Inc SENTRY INSTALLATION & SERVICE INSTRUCTIONS POWER SUPPLY UNIT Model HM-535 IMPORTANT SAFETY INSTRUCTIONS
More informationReference Manual EPM-PS1. PC/104-Plus Power Supply Module DOC. REV. 4/29/2009
Reference Manual DOC. REV. 4/29/2009 EPM-PS1 PC/104-Plus Power Supply Module WWW.VERSALOGIC.COM 12100 SW Tualatin Road Tualatin, OR 97062-7341 (503) 747-2261 Fax (971) 224-4708 Contents Copyright 2013
More informationUSER MANUAL CCHP-6000-XX 6kJ/s Capacitor Charging Power Supply
26 Ward Hill Ave., Bradford, MA 01835 Phone: 978-241-8260 Fax: 978-241-8262 USER MANUAL CCHP-6000-XX 6kJ/s Capacitor Charging Power Supply 02001235 Rev 1 CCHP-6000-XX User Manual Page 1 of 14 Table of
More informationCO2 Controller Operating Instructions Models: RAD-0501, RAD-0501A, RAD-0501E 1. Product Description
CO2 Controller Operating Instructions Models: RAD-0501, RAD-0501A, RAD-0501E 1. Product Description RAD-0501 Greenhouse Mode: Controls CO2 generator or regulator to increase CO2 levels during daylight
More informationHP R/T2200 UPS. Overview. Precautions. Installation Instructions. The HP UPS R/T2200 features power protection for loads up to 2200 VA/1600 W.
HP R/T2200 UPS Installation Instructions Overview The HP UPS R/T2200 features power protection for loads up to 2200 VA/1600 W. For more information about any of the topics covered in this document, see
More informationINSTRUCTION MANUAL RA 19-7B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES
INSTRUCTION MANUAL RA 19-7B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES KEPCO INC. An ISO 9001 Company. MODEL RA 19-7B RACK ADAPTER ORDER NO. REV. NO. IMPORTANT NOTES: 1) This manual
More information1. Unpacking the System
1. Unpacking the System To prevent shipping damage the system is packed in multiple boxes. Chassis The chassis in shipped in one box by itself. The chassis is shipped assembled. Inside the chassis you
More informationAC4G-D User s Manual
AC4G-D User s Manual Entire contents of this manual 2004 Active Cool Ltd. Ashkelon, Israel. Reproduction in whole or in part without permission is prohibited. Active Cool and AC4G-D are registered of Active
More informationSingle Phase Systems-North American PC125/PC420 Series
Single Phase Systems-North American PC125/PC420 Series Enclosure Power Distribution Units (epdu ) PC125-C Front RACK MOUNTED 19 x 3.4 (2U) x 8.5. Approximate shipping weight: 19 lbs. (12) NEMA OUTLETS
More informationSecured Series: Hub Plus Kit Single Door Controller Package Installation Manual
Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual This package is designed to simplify the connections to our Secured Series Hub Plus Controller. This will translate into
More information87421/22A Power Supply. Operating and Service Manual
87421/22A Power Supply Operating and Service Manual Agilent Part Number: 87421-90001 Printed in USA April 2001 Supersedes: September 1998 Notice The information contained in this document is subject to
More informationFollow the procedure below for unpacking the carton in which the device is shipped. DW-GTW-AC-E1060 Four anti-slide bumpers for desktop installation
1 Introduction This document provides a hardware description of the DW-GTW-AC-E1060 (hereafter referred to as device) and step-by-step procedures for mounting and cabling the device. The device supports
More informationPIX 520. PIX 520 Product Overview CHAPTER
CHAPTER 5 PIX 520 This chapter guides you through the installation of the PIX 520, and includes the following sections: PIX 520 Product Overview, page 5-1 Installing the PIX 520, page 5-4 PIX 520 Feature
More information20W Tungsten-Halogen Light Source. Operation Manual
20W Tungsten-Halogen Light Source - ASB-W-020 - Operation Manual Important Safety Notices 1. Never look directly into the light beam, including through the cooling fan while light is on, as this can cause
More information3710 ACM 3750 PDC 3800 RTU. ISOCOM Communications Card Retrofit Instructions
3710 ACM 3750 PDC 3800 RTU ISOCOM Communications Card Retrofit Instructions Danger During normal operation of this device, hazardous voltages are present which can cause severe injury or death. These
More informationINSTRUCTION MANUAL RA 55 RACK ADAPTER RACK ADAPTER FOR MST SERIES POWER MODULES
INSTRUCTION MANUAL RA 55 RACK ADAPTER RACK ADAPTER FOR MST SERIES POWER MODULES KEPCO INC. An ISO 9001 Company. MODEL RA 55 RACK ADAPTER ORDER NO. REV. NO. IMPORTANT NOTES: 1) This manual is valid for
More informationCisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2
Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2 Cisco CRS 3-Phase AC Power Distribution Unit 2 Revised: November 18, 2016,
More informationLightspeed Advanced Reporting Bottle Rocket Hardware Installation Guide
Lightspeed Advanced Reporting Bottle Rocket Hardware Installation Guide 1800 19th Street / Bakersfield, CA 93301 / Tel: 661.716.7600 / Toll Free: 877.447.6244 / www.lightspeedsystems.com Table of Contents
More informationInstalling the Cisco AS5400XM Universal Gateway
CHAPTER 3 Installing the Cisco AS5400XM Universal Gateway This chapter guides you through the installation of the Cisco AS5400XM universal gateway and includes the following sections: Setting Up the Chassis,
More informationINSTRUCTION MANUAL RA 55 RACK ADAPTER RACK ADAPTER FOR MST SERIES POWER MODULES
INSTRUCTION MANUAL RA 55 RACK ADAPTER RACK ADAPTER FOR MST SERIES POWER MODULES KEPCO INC. An ISO 9001 Company. MODEL RA 55 RACK ADAPTER ORDER NO. REV. NO. IMPORTANT NOTES: 1) This manual is valid for
More informationIKS-G6524A/G6824A Series Quick Installation Guide
IKS-G6524A/G6824A Series Quick Installation Guide Edition 3.0, February 2017 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777 Fax:
More informationMODEL No. SW1X8 RS422 SWITCHER
12843 Foothill Blvd. Suite C Sylmar, California 91342 V: 818.898.3380 F: 818.898.3360 sales@dnfcontrols.com MODEL No. SW1X8 RS422 SWITCHER User Manual TABLE OF CONTENTS I. REVISION HISTORY... 2 II. INTRODUCTION...
More information3-Phase, Dual-Input 6-Slot Power Supply System STARTUP GUIDE
3-Phase, Dual-Input 6-Slot Power Supply System STARTUP GUIDE -ST-01 Page 1 of 10 November 2016 2016 Copyright Lite-On Technology Corporation ALL RIGHTS RESERVED. Lite-On is a trademark of Lite-On Technology
More informationACLD Channel Opto-isolated Digital Input Board
ACLD-9182 16 Channel Opto-isolated Digital Input Board @ Copyright 1996 All Rights Reserved. Manual edition 01, January 1996 The information in this document is subject to change without prior notice in
More informationUSER MANUAL CCPF-500-XX CCPF-750-XX 500 to 750 J/s Capacitor Charging Power Supply Series
26 Ward Hill Ave., Bradford, MA 01835 Phone: 978-241-8260 Fax: 978-241-8262 USER MANUAL CCPF-500-XX CCPF-750-XX 500 to 750 J/s Capacitor Charging Power Supply Series 02100005 Rev 1 CCPF-500 CCPF-750 User
More informationUser Manual. Per Port Monitoring Models
User Manual Per Port Monitoring Models Table of Contents 1. Introduction... 1 2. Package Contents... 2 3. Function... 3 4. Installation... 5 5. Web Interface... 6 1. Introduction The ServerLink Per Port
More informationNI PXIe-1062Q Power Supply Shuttle
USER GUIDE NI PXIe-1062Q Power Supply Shuttle The NI PXIe-1062Q power supply shuttle is a replacement part for the NI PXIe-1062Q chassis. Caution This power supply is not compatible with any other National
More informationM82xxD Fiber Optic RS-232 MicroModem Technical Manual
M82xxD Fiber Optic RS-232 MicroModem Technical Manual Revision C August 2016 VERSITRON, Inc. 83 Albe Drive / Suite C Newark, DE 19702 www.versitron.com Safeguarding Communications Since 1958 PROPRIETARY
More information2-Way Wireless I/O Expander Installation Guide
2-Way Wireless I/O Expander Installation Guide For more detailed information please refer to the iconnect Installer Manual provided on our website: www.electronics-line.com Table of Contents 1. Introduction...
More informationUser Guide CPSMP VAC Power Supply Module: PointSystem CPSMC Accessory CPSMC Accessory. Contents.
User Guide CPSMP-205 110 240 VAC Power Supply Module: PointSystem CPSMC1800-200 Accessory CPSMC1900-100 Accessory Contents Contents...1 Description...1 Cautions and Warnings...2 Definitions...2 Power supply
More information1073N. Channel Amplifier. User Manual Issue 1.3
1073N Channel Amplifier User Manual 527-404 Health & Safety Notice For your own safety and for the protection of others, please observe the following safety precautions: Read these instructions. Keep these
More informationMTS-2000 USER S MANUAL
MTS-2000 USER S MANUAL USER s MANUAL - March 2010 MTS-2000 METER TEST SYSTEM Pay special attention to the warnings and safety instructions that accompany the above symbol wherever it is found within this
More informationInstallation Manual. Mounting Instructions Mechanical Mounting. Luminato. Teleste Corporation
Luminato Installation Manual Teleste Corporation Mounting Instructions Mechanical Mounting Luminato Mechanical Installation, agile_59300316, rev0044 Introduction 1 Contents Introduction 4 General... 4
More informationSATA II HDD Canister KISS DA 435 Quick Reference Guide
SATA II HDD Canister KISS DA 435 Quick Reference Guide If it s embedded, it s Kontron 1. Table of Contents SATA II HDD Canister KISS DA 435 1. Table of Contents 1. Table of Contents... 1 2. Important Information...
More information500 Business Center Drive Pittsburgh, PA USA CAGE 1BGJ7. SwitchMaster R5000 Series Ultra-Compact Ganged A/B Switching System
Market Central www.secureswitch.com 500 Business Center Drive Pittsburgh, PA 15205 USA 412.494.2800 CAGE 1BGJ7 SwitchMaster R5000 Series Ultra-Compact Ganged A/B Switching System July, 2014 COMPLETE 2
More informationASK-4 #101-DV AUDIO MONITORING SYSTEM INSTALLATION AND OPERATING INSTRUCTIONS
6955 VALJEAN AVE, VAN NUYS, CA 91406 PH: (818)994-6498 / FAX: (818)994-6458 techsupport@louroe.com / www.louroe.com ASK-4 #101-DV AUDIO MONITORING SYSTEM The ASK-4 #101-DV is a single zone audio monitoring
More informationIntegrated Stepper Drive & Motor
SMD23 Integrated Stepper Drive & Motor Manual #: 940-0S050 User Manual AMCI Motion Control Products Important User Information The products and application data described in this manual are useful in a
More informationPCM-7140 Pulsed Current Source Operation Manual
PCM-7140 Pulsed Current Source Operation Manual Directed Energy, Inc. 1609 Oakridge Dr., Suite 100, Fort Collins, CO 80525 (970) 493-1901 sales@ixyscolorado.com www.ixyscolorado.com Manual Document 7650-0031
More informationEnclosure TS-530 User Manual
Enclosure TS-530 User Manual 16525 East Laser Drive Fountain Hills, AZ 85268 TEL 480.837.5200 FAX 480.837.5300 info@embeddedx86.com http://www.embeddedx86.com/ Technologic Systems, Inc. COPYRIGHT 1998-200
More informationPower Rack 58. EXT-PS5-8R User Manual.
Power Rack 58 EXT-PS5-8R User Manual www.gefen.com ASKING FOR ASSISTANCE Technical Support: Telephone (818) 772-9100 (800) 545-6900 Fax (818) 772-9120 Technical Support Hours: 8:00 AM to 5:00 PM Monday
More information* * Agilent Power Distribution Unit (PDU) Installation Guide
Agilent Power Distribution Unit (PDU) Installation Guide For use with Agilent PDU kits and PDU installation kits for Agilent instrument racks June 2008 Edition 7 E0608 *5000-0039* 5000-0039 Notice The
More informationSVP110 SURGE VOLTAGE PROTECTOR INSTRUCTION MANUAL
SVP110 SURGE VOLTAGE PROTECTOR INSTRUCTION MANUAL REVISION: 01/03/03 COPYRIGHT (c) 1995-2000 CAMPBELL SCIENTIFIC, INC. This is a blank page. WARRANTY AND ASSISTANCE The SVP110 SURGE VOLTAGE PROTECTOR is
More informationInstallation and Operation Guide for PD5200 and PD5300 Automatic Transfer Switch
Installation and Operation Guide for PD5200 and PD5300 Automatic Transfer Switch PD52 PD52S & PD52DCS PD53-100 te: The PD52S & PD52DCS are provided with LED lights. The GREEN LIGHTS indicate Shore Power
More informationBasketball Shot Clock Set LX2180 Manual
Basketball Shot Clock Set LX2180 Manual 72 Industrial Boulevard Wrightsville, GA 31096 Phone: (800) 445-7843 Fax: (800) 864-0212 www.electro-mech.com LX2180 Revision 5 February 8, 2013 Table of Contents
More informationInstallation and Maintenance
CHAPTER 4 Installation and Maintenance Revised: April 19, 2010, Introduction This chapter explains how to install a SCE 1000 platform in a rack or in a general tabletop or workbench installation. Additionally,
More informationLINE VOLTAGE TESTER CT101 USER S MANUAL. Please read this manual carefully and thoroughly before using this product.
LINE VOLTAGE TESTER USER S MANUAL CT101 Please read this manual carefully and thoroughly before using this product. KEY FEATURES Visual indication of AC or DC voltage Easy to use approved Safe for CAT
More informationAEXX-273 SERIES WIRELESS CONTROLLED PACE CLOCKS
FN:273MAN1.DOC AEXX-273 SERIES WIRELESS CONTROLLED PACE CLOCKS DESCRIPTION AEXX-273 Series Wireless Controlled Pace Clocks are available in with 1", 2.3", 4", 8", or 12" high digits, visible from 5 feet
More informationFD141CV-C-1. Installation and Operation Manual. 14 Widescreen HD Display. Revision Date: 05/04/2017 Page 1 of 15. Rev: B
Page 1 of 15 Installation and Operation Manual FD141CV-C-1 14 Widescreen HD Display Page 2 of 15 Table of Contents General Information...3 Front View...3 Additional Information...3 Specifications...4 Installation
More informationTable of Contents. 1. Introduction Package Contents Function Installation Web Interface... 4
User Manual Table of Contents 1. Introduction... 1 2. Package Contents... 2 3. Function... 3 4. Installation... 2 5. Web Interface... 4 1. Introduction The ServerLink PDU is a network ready device designed
More informationEMC1600 Series Media Converter and Ethernet Extender Chassis
EMC1600 Series Media Converter and Ethernet Extender Chassis User s Manual Preface This manual describes how to install and use the 16-Bay Media Converter and Ethernet Extender Chassis. This chassis is
More informationMAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS
MAINTENANCE MANUAL EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS SPECIFICATIONS*... 2 INTRODUCTION... 3 DESCRIPTION...
More informationINSTRUCTION MANUAL. SGB20(D) Transient Protection System. June Copyright 2008 Campbell Scientific (Canada)Corp.
INSTRUCTION MANUAL SGB20(D) Transient Protection System June 2008 Copyright 2008 Campbell Scientific (Canada)Corp. WARRANTY AND ASSISTANCE This equipment is warranted by CAMPBELL SCIENTIFIC (CANADA) CORP.
More informationInstallation RA5112-C-16A-C20. Basic Rack Power Distribution Unit
Installation RA5112-C-16A-C20 Basic Rack Power Distribution Unit Contents Before You Begin........................1 Safety and grounding information..........1 How to Install the Rack PDU...............2
More informationSeries 8000 RF Signal Switch Solution
RF Signal Switch Solution Operation Manual Operation Manual, Part Number 07508000-006, Rev. A, May 17, 2013 All technical data and specifications in this publication are subject to change without prior
More informationBTU-4D/BTU-4D-I Digital Temperature Unit & Sensors. Installation and Operation Manual
BTU-4D/BTU-4D-I Digital Temperature Unit & Sensors Installation and Operation Manual BTU-4D/BTU-4D-I Installation and Operation Manual Rev E Table of Contents Introduction... 1 TEMP OUTDOOR Sensor... 1
More informationS66 Series Electronic Fan Speed Control
FANs 121, 125, 1628.3 Product/Technical Bulletin S66 Issue Date 0918 S66 Series Electronic Fan Speed Control The S66 Series Electronic Fan Speed Control is designed to modulate the speed of single-phase,
More informationInstallation & Operation Guide
Installation & Operation Guide (Shown with optional Override Board Cover) KMD-5831 Programmable Loop Controller PLC-28 Direct Digital Controller 902-019-04B 1 Introduction This section provides a brief
More informationINSTRUCTIONS FOR LED INDUSTRIAL LIGHTING LIGHT STRIPS AND WORK LIGHTS
INSTRUCTIONS FOR LED INDUSTRIAL LIGHTING LIGHT STRIPS AND WORK LIGHTS These lights use extremely bright, cool white, energy-efficient LEDs and are effective in directing the light to the work area. Light
More informationMFA-0801 & MFA-1201 D-M-E Smart Series Low Voltage Temperature Control System. User s Manual. D-M-E Company
MFA-0801 & MFA-1201 D-M-E Smart Series Low Voltage Temperature Control System User s Manual D-M-E Company D-M-E Company MFA-0801 & MFA-1201 Page 1 Copyright D-M-E Company 1995. All rights reserved. D-M-E
More informationT-Monitor E-Monitor TABLE OF CONTENTS SECTION 1 - DESCRIPTION...2 SECTION 2 - SPECIFICATIONS...3 SECTION 3 - INSTALLATION...5
T-Monitor E-Monitor TABLE OF CONTENTS SECTION - DESCRIPTION... SECTION - SPECIFICATIONS...3 SECTION 3 - INSTALLATION... SECTION - FRONT PANEL INDICATORS...7 SECTION - INTERFACE SIGNALS AND CABLES...8 SECTION
More informationBTU 4 & Sensors. Installation and Operation Manual
BTU 4 & Sensors Installation and Operation Manual Table of Contents Introduction... 1 Sensors... 1 BTO Outdoor Sensor... 1 BTI Indoor Sensor... 2 BTS Stack Sensor... 2 Installation... 3 BTU 4 Burk Temperature
More information