SM9000. Made in Germany
|
|
- Gwendolyn Lester
- 5 years ago
- Views:
Transcription
1 Made in Germany Product characteristics Magnetic-inductive flow meter Connector Process connection: G2 flat seal connection to pipe by means of an adapter Function programmable Totaliser function Empty pipe detection 2 outputs OUT1: flow monitoring (binary), quantity meter (pulse), preset counter (binary) OUT2: flow or temperature monitoring (analogue or binary) Input for counter reset 4-digit alphanumeric display
2 l/min C Application Application Medium temperature Electrical data Electrical design Operating voltage [V] Current consumption [ma] Insulation resistance [MΩ] Protection class Reverse polarity protection Outputs Output function Current rating [ma] Voltage drop [V] Short-circuit protection Overload protection Analogue output Max. load [Ω] Min. load [Ω] Pulse output Frequency range [Hz] Measuring / setting range Empty pipe detection Resolution Reset point, rp Analogue start point, ASP Analogue end point, AEP Flow end point, FEP Low flow cut-off, LFC Measuring dynamics Frequency end point, FrEP Volumetric flow quantity monitoring Conductive liquids (conductivity:>= 20 µs/cm / viscosity: < 70 mm²/s at 40 C) DC PNP/NPN DC ¹) < 150 > 100 (500 V DC) III OUT1: normally open / normally closed programmable or pulse or frequency or empty pipe detection or IO-Link OUT2: normally open / normally closed programmable or analogue ( ma; V, scalable) or empty pipe detection l/min l/min 0.5 l/min l/min l/min l/min l/min 0.5 l/min 2 x 250 < 2 pulsed ma; V 500 ( ma) 2000 ( V) flow rate meter normally closed / open l/min; m³/h l/min; m³/h 1: khz 10 Hz x 10³ m³/h m³/h 0.02 m³/h m³/h m³/h m³/h m³/h 0.02 m³/h
3 Pulse value Pulse length Resolution Reset point, rp Analogue start point, ASP Analogue end point, AEP Accuracy / deviations Accuracy Repeatability Pressure loss (dp) / flow rate (Q) x 10³ x 10³ 0.1 l x 10³ m³ 0.1 l ± (0.8% MW + 0.5% MEW) ²) ± 0.2% MEW Accuracy Temperature drift Reaction times Power-on delay time Start-up delay Response time Damping, dap Response time Software / programming Programming options [K] ± 1 (25 C; Q > 15 l/min) ± C / K < 0.25 (dap = 0) T09 = 3 (Q > 15 l/min) Hysteresis / window; NO / NC; output logic; current / voltage / frequency / pulse output; start-up delay; display can be deactivated; display unit; empty pipe detection
4 Interfaces IO-Link Device Transfer type IO-Link revision SDCI standard IO-Link Device ID Profiles SIO mode Required master port type Process data analogue Process data binary Min. process cycle time Environment Pressure rating Ambient temperature Storage temperature Protection Tests / approvals EMC EC pressure equipment directive 97/23/EC Shock resistance Vibration resistance Mechanical data Process connection Materials (wetted parts) Housing materials Weight Displays / operating elements Display Electrical connection Connection Wiring [ms] [bar] [kg] COM2 (38.4 kbaud) 1.1 IEC CDV 359 d / h Smart Sensor: Process Data Variable; Device Identification A IP 65 / IP 67 DIN EN ESD: 4 kv CD / 8 kv AD DIN EN HF radiated: 10 V/m DIN EN Burst: 2 kv DIN EN Surge: 1 kv DIN EN HF conducted: 10 V DIN EN : DIN EN : G2 flat seal 20 g (11 ms) 5 g ( Hz) stainless steel 316L / ; stainless steel 316Ti / ; PEEK (polyether ether ketone); Hastelloy C-4 (2.4610); Centellen; FKM stainless steel 316L / ; stainless steel 316Ti / ; PC (polycarbonate); FKM; PBT-GF 20; elastolan Display unit 6 x LED green (l/min, m³/h, l, m³, 10³, C) Switching status 2 x LED yellow Measured values 4-digit alphanumeric display Programming 4-digit alphanumeric display M12 connector; gold-plated contacts
5 OUT1/IO-Link: 5 selection options - switching output empty pipe detection - switching output flow rate monitoring - frequency output flow rate monitoring - pulse output quantity meter - signal output preset counter OUT2/InD: 6 selection options - switching output empty pipe detection - switching output flow rate monitoring - switching output temperature monitoring - analogue output flow rate - analogue output temperature - input signal counter reset Accessories Accessories (included) Remarks Remarks Pack quantity [piece] 2 x packing washer (Centellen); Label ¹) to DIN EN 50178, SELV, PELV ²) Q > 15l/min, Mediums- und Umgebungstemperatur +22 C ± 4K MW = measured value MEW = final value of the measuring range 1 ifm electronic gmbh Friedrichstraße Essen We reserve the right to make technical alterations without prior notice. GB SM
SM9000. Magnetic-inductive flow meter. Made in Germany
Made in Germany Application Application totaliser function; empty pipe detection; for industrial applications Installation connection to pipe by means of an adapter Media conductive liquids; water; hydrous
More informationInstallation Instructions Temperature transmitter TAA /00 06/2011
Installation Instructions Temperature transmitter TAA431 706042/00 06/2011 Contents 1 Functions and features...3 2 Installation...4 2.1 Addressing...4 2.2 Mechanical installation...4 2.3 Connection to
More informationOperating instructions Electronic pressure sensor. PM205x /01 09/2011
Operating instructions Electronic pressure sensor PM205x 706071/01 09/2011 Contents 1 Preliminary note...3 1.1 Symbols used...3 2 Safety instructions...3 3 Functions and features...4 3.1 Applications...4
More informationOperating instructions Pressure sensor. PN50xx / / 2010
Operating instructions Pressure sensor PN50xx 704789 / 00 05 / 2010 Contents 1 Preliminary note...3 1.1 Symbols used...3 2 Safety instructions...3 3 Functions and features...4 4 Function...5 4.1 Processing
More informationOperating instructions Memory plug E /02 11/2011
Operating instructions Memory plug E30398 UK 704930/02 11/2011 Contents 1 Preliminary note...3 1.1 Symbols used...3 1.2 Terms used...3 2 Safety instructions...4 3 Factory setting...4 4 Functions and features...5
More informationOriginal operating instructions Fail-safe inductive sensor GF711S / / 2013
Original operating instructions Fail-safe inductive sensor GF7S 8528 / 5 / 23 Contents Preliminary note...3. Explanation of symbols...3 2 Safety instructions...4 2. Safety-related requirements regarding
More informationOriginal operating instructions Fail-safe inductive sensor GG711S
Original operating instructions Fail-safe inductive sensor GG7S 8236522 / 2 / 26 Contents Preliminary note...3. Symbols used...3.2 Warning signs used...3 2 Safety instructions...4 2. Safety-related requirements
More informationOriginal operating instructions Fail-safe inductive sensor GI712S
Original operating instructions Fail-safe inductive sensor GI712S 80236527 / 00 12 / 2016 Contents 1 Preliminary note...3 1.1 Symbols used...3 1.2 Warning signs used...3 2 Safety instructions...4 2.1 Safety-related
More informationPressure switch RE B/ Type HEDE10.../1/ Operating instructions
Pressure switch Type HEDE10.../1/ RE 30276-B/10.10 Replaces: 06.10 Operating instructions 2/20 Bosch Rexroth AG HEDE10.../1/ RE 30276-B/10.10 Contents 1 Overview of menu...3 2 Safety note... 4 3 Operating
More informationModular pressure transmitters for harsh environments DST P500, DST P507 and DST P550
Data sheet Modular pressure transmitters for harsh environments DST P500, DST P507 and DST P550 The P500 / P507 / P550 utilizes the thin film strain gauge sensing technology, incorporating an hermetically
More informationOperating instructions Pressure sensor. PN78xx / / 2010
Operating instructions Pressure sensor PN78xx UK 704788 / 00 05 / 2010 Contents 1 Preliminary note3 1.1 Symbols used 3 2 Safety instructions 3 3 Functions and features 4 4 Function 5 4.1 Processing of
More informationOperating instructions Programming and display unit PP / / 2010
Operating instructions Programming and display unit PP2001 704795 / 00 05 / 2010 Contents 1 Preliminary note3 1.1 Explanation of symbols 3 2 Safety instructions 3 3 Items supplied 4 4 Functions and features
More informationFusion of electronic pressure sensor and analogue display.
Fusion of electronic pressure sensor and analogue display. Pressure sensors www.ifm.com/gb/pg fluid sensors and diagnostic systems position sensors and object recognition bus, identification and control
More informationOperating instructions Electronic temperature sensor TN /00 04/2011
Operating instructions Electronic temperature sensor TN7531 UK 704772/00 04/2011 Contents 1 Preliminary note3 1.1 ymbols used 3 2 afety instructions 3 3 Functions and features 4 4 Function 4 4.1 Communication,
More informationOperating instructions Pressure sensor. PE30xx / / 2010
Operating instructions Pressure sensor PE30xx UK 704884 / 00 08 / 2010 Contents 1 Preliminary note3 1. ymbols used 3 2 afety instructions 3 3 Functions and features 4 4 Function 5 4.1 Processing of the
More informationInnovation on the right wavelength. Level measurement in compact tanks using microwave technology.
Level sensors www.ifm.com/gwr Innovation on the right wavelength. Level measurement in compact tanks using microwave technology. The innovative measuring principle for high ease of use and low cost. evaluation
More informationOperating instructions Control monitor for temperature sensors TR /00 04/2011
Operating instructions Control monitor for temperature sensors TR7432 704773/00 04/20 Contents Preliminary note3. ymbols used 3 2 afety instructions 3 3 Functions and features 4 4 Function 4 4. Communication,
More informationElectronic timer CT-AHD.22
2CDC 251 093 F0t06 a Rotary switch for the preselection of the time range b Potentiometer with direct reading scale for the fine adjustment of the time delay c U: green LED V control supply voltage applied
More informationElectronic timer CT-ERS.12 ON-delayed with 1 c/o contact Data sheet
2CDC 251 056 F0t07 Features Rated control supply voltage 24-48 V DC, 24-240 V AC Single-function ON-delay timer One device includes 10 time ranges (0.05 s - 300 h) 1 c/o contact 2 LEDs for status indication
More informationJUMO MIDAS C08. OEM Pressure Transmitter Basic. Applications. Brief description. Special features. Customer benefits
Data Sheet 4000 Page /0 JUMO MIDAS C08 OEM Pressure Transmitter Basic Applications compressors machinery and plant engineering industrial pneumatics commercial vehicles building technology Brief description
More informationOperating instructions Pressure sensor. PN70xx / / 2012
Operating instructions Pressure sensor PN70xx 706136 / 00 01 / 2012 Contents 1 Preliminary note...3 1.1 ymbols used...3 2 afety instructions...3 3 Functions and features...4 4 Function...5 4.1 Communication,
More informationElectronic timer CT-ERS.21
2CDC 251 057 F0t07 Features Rated control supply voltage 24 240 V AC/DC Single function ON delay timer One device includes 10 time ranges (0.05 s 300 h) 2 c/o contacts 2 LEDs for status indication Width
More informationXMLR400M1P25 Pressure sensors XMLR 400bar - G 1/4-24VDC ma - PNP - M12
Characteristics Pressure sensors XMLR 400bar - G 1/4-24VDC - 4..20 ma - PNP - M12 Complementary Current consumption Electrical connection Type of output signal Analogue output function Discrete output
More informationContact protection relay
Contact protection relay Ordering details SVR 450 08 F0000 The protects sensitive control contacts from excessive load. It can be used with latching function or without. Bounce time of control contacts
More informationILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description
Inline Block IO Module for PROFIBUS With 32 Digital Outputs AUTOMATIONWORX Data Sheet 6889_en_04 Description PHOENIX CONTACT - 03/2007 & & ' ) The ILB PB 24 DO32 module is designed for use within a PROFIBUS
More informationLinear Position Transducer HLT 1000-R2
7 Linear Position Transducer HLT 1000-R2 Description: The sensor works on the principle of magnetostriction. This measuring principle determines with high accuracy the position, distance and/or speed and
More informationElectronic timer CT-ERD.12
2CDC 251 092 F0t06 a Rotary switch for the preselection of the time range b Potentiometer with direct reading scale for the fine adjustment of the time delay c U: green LED V control supply voltage applied
More informationInductive proximity sensors IQ 40 series, sensing range 15 / 20 mm DC 3-wire, plastic housing
Inductive proximity sensors IQ 40 series, sensing range 15 / 20 mm DC 3wire, plastic housing Dimensions in mm 121 PG 13,5 101 27 Features Can be installed flush or nonflush in metal Variable switching
More informationElectronic pressure switch with display Model PSD-4
Electronic pressure measurement Electronic pressure switch with display Model PSD-4 WIKA data sheet PE 81.86 Applications Machine tools Hydraulics and pneumatics Pumps and compressors Special-purpose machine
More informationJUMO MIDAS C08. OEM Pressure Transmitter Basic. Applications. Brief description. Special features. Customer benefits
sales@jumo.co.uk info.us@jumo.net Page /0 JUMO MIDAS C08 OEM Pressure Transmitter Basic Applications compressors machinery and plant engineering industrial pneumatics commercial vehicles building technology
More informationXMLK006B2C21 pressure sensor XMLK bar - G 1/4A mA - DIN - set of 1
Characteristics pressure sensor XMLK - 0..6bar - G 1/4A - 4..20mA - DIN - set of 1 Complementary Pressure setting range Maximum permissible accidental pressure Destruction pressure Materials in contact
More informationElectronic timer CT-ARS.11
2CDC 251 088 F0t07 Features Rated control supply voltage 24 240 V AC/DC Single function OFF delay timer without auxiliary voltage One device includes 7 time ranges (0.05 s 10 min) 1 c/o (SPDT) contact
More informationNOVOHALL Rotary Sensor non-contacting. Series RSC2800 digital SSI, SPI, Incremental
NOVOHALL Rotary Sensor non-contacting Series RSC2800 digital SSI, SPI, Incremental The contactless sensor utilizes the orientation of a magnetic field for the determination of the measurement angle. The
More informationLMP 308. Separable Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO / 0.
LMP 08 Separable Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.25 % FSO / 0. % FSO Nominal pressure from 0... mh 2 O up to 0... 250 mh 2 O Output signals 2-wire:
More informationVert-X 32E - 24V / CANopen, redundant. Applications Forklifter Platformer Agricultural machine. Features. CiA approved CiA V402/
Sensor principle MH-C2 Electrical data Measuring range 0... 360 Indep. linearity (typ.) % of meas. range ±0.3 Max. hysteresis 0.1 Resolution bit 16 Max. repeatability 0.1 Sample rate khz 0.5 Max. temperature
More informationPressure transmitter for highest pressure applications Up to 217,500 psi (15,000 bar) Model HP-2
Electronic pressure measurement Pressure transmitter for highest pressure applications Up to 217,500 psi (15,000 bar) Model HP-2 WIKA data sheet PE 81.53 Applications Test bench construction Water jet
More informationOperating instructions Combined pressure sensor. PN22xx / / 2010
Operating instructions Combined pressure sensor PN22xx UK 704829 / 00 08 / 2010 Contents 1 Preliminary note 3 1.1 ymbols used 3 2 afety instructions 3 3 Function and features 4 4 Function 5 4.1 Communication,
More informationPressure switch type DG 51 E
Pressure switch type DG 51 E Product documentation Operating pressure pmax: 600 bar D 5440 E/2 05-2017-1.0 by HAWE Hydraulik SE. The reproduction and distribution of this document as well as the use and
More informationCommunication. Features. Device variant. Copyright 2017, Builder: , Time: 01:29:48
Version V2.2.9 Release date 217-9-6 Copyright 217, Builder: 2.5.3.9, Time: 1:29:48 SM Vendor ID Device ID Vendor name Vendor text Vendor URL 31 / x136 - s: 1 54 / x1 x36 59 / x1fd - s: 1 253 / x x1 xfd
More informationDCT 531. Industrial Pressure Transmitter with RS485 Modbus RTU. Stainless Steel Sensor
DCT 5 Industrial Pressure Transmitter with RS85 Modbus RTU Stainless Steel Sensor accuracy according to IEC 60770: : 0.5 % FSO option: 0.5 % FSO Nominal pressure from 0... 00 mbar up to 0... 00 bar output
More informationLevel sensor Stainless steel version Model RLT-1000, for industrial applications
Level measurement Level sensor Stainless steel version Model RLT-1000, for industrial applications WIKA data sheet LM 50.02 Applications Level measurement of liquids in machine building Control and monitoring
More informationM5100 Heavy Industrial Pressure Transducer
CE Compliance Wide Temperature Range Compact Variety of Pressure Ports and Electrical Configurations DESCRIPTION The M5100 series pressure transducers from the Microfused line of MEAS, set a new price
More informationDMP 333 DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial
DMP Industrial Pressure Transmitter For High Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO Industrial Pressure Transmitter DMP Nominal pressure
More informationPressure sensor For highest pressure applications to 15,000 bar Model HP-2
Pressure Pressure sensor For highest pressure applications to 15,000 bar Model HP-2 WIKA data sheet PE 81.53 for further approvals see page 6 Applications Test bench construction Water jet cutting High-pressure
More informationNOVOHALL Rotary Sensor non-contacting. Series RSX-7900
NOVOHALL Rotary Sensor non-contacting Series RSX-7900 Special features very robust design to extreme environmental conditions high shaft load 300 N non-contacting, magnetic measuring angles up to 360 in
More informationVert-X 05E 5V / % Ub. Application Access control systems Forklift
Sensor principle MH-C MH-C2 Electrical Data Measuring range 0... 360 - Indep. linearitiy (without misalignment) % of meas. range ±0.3 - Indep. linearitiy (with allowed misalignment @ 360 ) % of meas. range
More informationOperating instructions Pressure sensor. PN70xx / / 2010
Operating instructions Pressure sensor PN70xx 704917 / 00 08 / 2010 Contents 1 Preliminary note 3 1.1 ymbols used 3 2 afety instructions 3 3 Functions and features 4 4 Function 5 4.1 Processing of the
More informationFusion of electronic pressure sensor and analogue display.
Fusion of electronic pressure sensor and analogue display. Pressure sensors www.ifm.com/gb/pg fluid sensors and diagnostic systems position sensors and object recognition bus, identification and control
More informationThread length (overall length) material
Cylindrical Proximity Sensor for Mobile Usage Designed and tested to keep your machines moving IP69k tested and certified for highest water resistance e1 type approval (according to automotive directive
More informationDI572 Digital Input Module
Ordering Data DATA SHEET DI572 Digital Input Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 230 500 R0000 1TNE 968 901 R3101 1TNE 968 901 R3102 1TNE 968 901 R3103 1TNE 968
More informationLinear Position Transducer HLT 1000-R2
Linear Position Transducer HLT 1000-R2 Description: The sensor works on the principle of magnetostriction. This measuring principle determines with high accuracy the position, distance and/or speed and
More informationADVANCED ultrasonic sensors with 2 switching outputs. Dimensioned drawing
Dimensioned drawing en 2-214/2 5124879 25 4mm 15 13mm 15-3 V DC We reserve the right to make changes DS_HTU418BX3LT4_en_5124879.fm Largely surface-independent function, ideal for the detection of liquids,
More informationTemperature Switches
ETS 00 Series Temperature Switch for Inline and Tank Mounting Applications Description The ETS 00 is a compact electronic temperature switch with 4-digit digital display. Pressure resistant to 8700 psi,
More informationMID approval no. DE-08-MI004-PTB004 Date of release
1. Identification Energy and Flow Computer Flow rate and energy calculator for liquids, gases and water steam E-DB-1000-700-01 MID approval no. DE-08-MI004-PTB004 Date of release 04.01.08 2. Area of Application
More informationAbsolute Encoders Multiturn
The multiturn encoders 5868 and 5888 with interface and optical sensor technology are ideal for use in all applications with a interface. The encoder supports the isochronous (IRT) mode and is therefore
More informationDistance and Position Sensors
Distance and Position Sensors SENSORS FOR DISTANCE AND POSITION Using various measuring techniques, HYDAC offers different distance and position sensors for a wide array of mobile and stationary applications.
More informationNOVOHALL Rotary Sensor touchless transmissiv. Series RFC4800 SSI, SPI, Incremental
NOVOHALL Rotary Sensor touchless transmissiv Series RFC4800 SSI, SPI, Incremental The sensor utilizes the orientation of a magnetic field for the determination of the actual position. Therefore, a magnet
More informationNOVOTURN Multiturn-Sensor non-contacting. Series RSM2800 digital SSI, SPI
NOVOTURN Multiturn-Sensor non-contacting Series RSM2800 digital SSI, SPI Special features True Power On System: counts turns even when not powered. Patented non-volatile technology does not require gears
More informationILBIB24DO16-DSUB. Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors
Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors AUTOMATIONWORX Data Sheet 7119_en_02 PHOENIX CONTACT - 03/2007 Description The ILB IB 24 DO16-DSUB module
More informationElectronic Level Switch ENS 3000
Electronic Level Switch ENS 3000 Description: The ENS 3000 is an electronic level switch with integrated display. The instrument has 1, 2 or 4 switching outputs and an analogue output signal is available
More informationAI561 Analog Input Module
Ordering Data DATA SHEET AI561 Analog Input Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1TNE 968 902 R1101 AI561, analog input module, 4 AI, U/I 1TNE 968 901 R3101 1TNE 968
More informationOperating Principle Capacitive proximity sensors
Operating Principle Capacitive proximity sensors Sensing flag Active surface RCoscillation circuit Signal analyser The active element in a capacitive proximity sensor consists of a sensor electrode and
More informationDC562, digital input/output module,
Ordering Data DATA SHEET DC562 Digital Input/Output Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 231 900 R0000 1TNE 968 901 R3101 1TNE 968 901 R3102 1TNE 968 901 R3103 1TNE
More informationCompact Inductive Proximity Sensor
SERIES Compact Inductive Proximity Sensor Amplifier Built-in High functionality together with robust housing and flexible cable Miniature is an amplifier built-in inductive proximity sensor having a diameter
More informationElectronic pressure switch with display For sanitary applications Model PSA-31
Electronic pressure measurement Electronic pressure switch with display For sanitary applications Model PSA-31 WIKA data sheet PE 81.85 Applications Food and beverage industry Pharmaceutical industry Filling
More informationNOVOTURN Multiturn Sensor non-contacting Series RSM2800 analog
NOVOTURN Multiturn Sensor non-contacting Series RSM2800 analog Special features non-contacting, magnetic long life electr. angle 720 up to 5760 in 360 -steps available (equates 2... 16 turns) continuous
More informationDC561, digital input/output module,
Ordering Data DATA SHEET DC561 Digital Input/Output Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1TNE 968 902 R2001 DC561, digital input/output module, 16 configurable inputs/outputs,
More informationTemperature measurement TER8 Front-flush and low-invasive resistance thermometers
Product highlights 3-A fulfillment without elastomers Front-flush or immersed types Accurate reading independent on ambient temperature Fast response time Hermetically sealed towards process Capable of
More informationSwitching relay CT-IRS with 1, 2 or 3 c/o contacts Data sheet
1SVR 430 221 F7300 2 1 3 Characteristics Switching relay ON-delay approx. 10 ms 1, 2 or 3 c/o contacts Switching relay with gold-plated contacts Width 22.5 mm Approvals e f GOST CCC CT-IRS 1 U/R: green
More informationInductive proximity switches with long operating distance, series 500
Inductive proximity switches with long operating distance, series 500 Highlights World's longest operating distances on steel Sizes Ø 4... M30 embeddable (Ø 4 and M5), (... M30) and non-embeddable (M...
More informationFL MC 2000E (SM40) LC
IEC 61850 fiber optic converter with LC fiber optic connection (1310 nm) to convert 100Base-Tx to single- or multi-mode fiber glass Data sheet 3205_en_C 1 Description PHOENIX CONTACT 2014-04-04 2 Features
More informationAO561 Analog Output Module
Ordering Data DATA SHEET AO561 Analog Output Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1TNE 968 902 R1201 AO561, analog output module, 2 AO, U/I 1TNE 968 901 R3102 Terminal
More informationPRCMT18-5DO PRCMT18-5DC PRCMT18-5DO-I PRCMT18-5DC-I
PRCM Series Cylindrical Connector Type Proximity Sensor Features Improved the noise immunity with dedicated IC Built-in reverse polarity protection circuit (DC -wire type) Built-in surge protection circuit
More informationElectronic pressure switch with display For sanitary applications Model PSA-31
Electronic pressure measurement Electronic pressure switch with display For sanitary applications Model PSA-31 WIKA data sheet PE 81.85 Applications Food and beverage industry Pharmaceutical industry Filling
More informationPSR-MS60. Safety relay for emergency stop, safety door and light grid monitoring. Data sheet. 1 Description
SILCL IEC 62061 Safety relay for emergency stop, safety door and light grid monitoring Data sheet 106171_en_01 PHOENIX CONTACT 2015-05-19 1 Description Intended Use The PSR-MS60 safety relay can be used
More informationOperating instructions Mechatronic flow sensor SBY2xx SBG2xx SBN2xx SB0524
Operating instructions Mechatronic flow sensor SBY2xx SBG2xx SBN2xx SB0524 UK 80256992 / 00 11 / 2016 Contents 1 Preliminary note...4 1.1 Symbols used...4 2 Safety instructions...4 3 Functions and features...5
More informationDI561 Digital Input Module
Ordering Data DATA SHEET DI561 Digital Input Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1TNE 968 902 R2101 1TNE 968 901 R3101 1TNE 968 901 R3103 1TNE 968 901 R3105 DI561, digital
More informationDX561 Digital Input/Output Module
Ordering Data DATA SHEET DX561 Digital Input/Output Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1TNE 968 902 R2301 1TNE 968 901 R3101 DX561, digital input/output module, 8 DI
More informationFork light barriers SOOF
Product range overview Method of measurement Size Min. object diameter Max. switching frequency Switching output Type of light Page/ Internet [mm] [mm] [Hz] Metal light barrier SOOF-M- -C30 30x35 0.5 4,000
More informationE4PA. Ultrasonic Displacement Sensor. Ordering Information
Ultrasonic Displacement Sensor Ideal for controlling liquid level. Long sensing distance and high-resolution analog output. High-precision detection with a wide range of measurements Four types of Sensors
More informationEnergy Management Modular DC Energy analyzer Type VMU-E and VMU-X
Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X Modular solution based on the combination of two units: VMU-E analysis unit and VMU-X universal power supply and RS485 communication unit.
More informationElectronic pressure sensors
Presentation, type XML P For control circuits Presentation Pressure transmitters XML P are characterised by their thin fi lm technology. The stainless steel pressure sensing capsule is directly welded
More informationMINI MCR-SL-UI-REL(-SP)
Configurable Threshold Value Switch Data Sheet 11/2004 Method of Operation The configurable 3-way threshold value switch MINI MCR-SL-UI-REL(-SP) is used to control and monitor analog standard signals.
More informationDS 201P. Electronic Pressure Switch. Pressure Port With Flush Welded Stainless Steel Diaphragm. accuracy according to IEC 60770: 0.
Pressure Port With Flush Welded Stainless Steel Diaphragm accuracy according to IEC 600: 0. % FSO Nominal pressure from 0... 60 bar up to 00 bar Contacts, or independent PNP contacts, freely configurable
More informationJUMO PINOS L01. Calorimetric flow sensor. Brief description. Special features. Customer benefits. Data Sheet
sales@jumo.co.uk info.us@jumo.net Page 1/9 JUMO PINOS L01 Calorimetric flow sensor Brief description The JUMO PINOS L01 flow sensor serves the measuring and monitoring of flow velocities of water and aqueous
More informationTRIO-DIODE/12-24DC/2X10/1X20
Redundancy module INTERFACE Data sheet 104278_en_00 1 Description PHOENIX CONTACT 20100423 Features TRIO DIODE is the DINrail mountable redundancy module from the TRIO POWER product range. Using the redundancy
More informationADVANCED ultrasonic sensors with 2 switching outputs. Dimensioned drawing
ADVANCED ultrasonic sensors with 2 switching outputs Dimensioned drawing en 4-214/12 5124879 25 4mm 15 13mm 15-3 V DC We reserve the right to make changes DS_HTU418BX3LT4_en_5124879.fm Function largely
More informationLMP 308i. Separable Stainless Steel Probe Precision. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO
Separable Stainless Steel Probe Precision Stainless Steel Sensor accuracy according to IEC 60770: 0. % FSO Nominal pressure from 0... mho up to 0... 00 mho Output signals wire:... 0 ma wire: 0... 0 V others
More informationDatasheet - CSS 11-30S-D-M-ST
12.02.2013-18:42:30h Datasheet - CSS 11-30S-D-M-ST Safety sensors / CSS 30S Preferred typ Stainless steel enclosure Max. 31 sensors can be wired in series. Connector M12, 8-pole Ø M30 High repeat accuracy
More informationElectronic timer CT-APS.21 OFF-delayed with 2 c/o (SPDT) contacts
Data sheet Electronic timer CT-APS.21 OFF-delayed with 2 c/o (SPDT) contacts The CT-APS.21 is an electronic timer from the CT-S range with OFF-delay. It provides 10 time ranges and a continuous rated control
More informationElectronic timer CT-AHS OFF-delayed with 2 c/o contacts Data sheet
2CDC 251 113 F0004 CT-AHS 1 7 2 6 5 4 8 3 1 10 selectable time ranges, from 0.05 s to 300 h 2 Potentiometer with direct reading scale for the fine adjustment of the time delay 3 Sliding switch to set the
More informationMagnetically Inductive Flowmeter
Magnetically Inductive Flowmeter Construction The GEMÜ mflow flowmeter operates according to the magnetically inductive measurement principle. It is suitable for electrically conductive media and enables
More informationFerrous metal (The sensing distance decreases with non-ferrous metal.) Power supply voltage (operating voltage range)
Description The sensors provide excellent results even with difficult-to-detect objects, e.g. small or thin parts, wires or bright metals. A variety of types cover a wide range of individual requirements
More informationXMLP200PD730 pressure transmitter - XMLP - 200psi - 1/4"18NPT V - M12 - set 1
Characteristics pressure transmitter - XMLP - 200psi - 1/4"18NPT - 0..10V - M12 - set 1 Complementary Pressure setting range Maximum permissible accidental pressure Destruction pressure Materials in contact
More informationElectronic timer CT-EBD.12 Flasher starting with ON with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-EBD.12 Flasher starting with ON with 1 c/o (SPDT) contact The CT-EBD.12 is an electronic time relay with the function flasher starting with ON. It is from the CT-D range.
More informationM7100 Pressure Transducer
Pressure Transducer Performance standard to on and off highway engines and vehicle OEMs Rugged for heavy equipment and outdoor use Designed specifically for high volume applications Stainless Steel wetted
More informationPST...-R ELECTRONIC PRESSURE SWITCHES
PST...-R ELECTRONIC PRESSURE SWITCHES PRODUCT DATA FEATURES Precise pressure monitoring Corrosion-resistant stainless steel sensor Rugged electronics Suitable for outdoor use High accuracy and stability
More informationCI542 PROFIBUS Communication Interface Module
Ordering Data DATA SHEET CI542 PROFIBUS Communication Interface Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 224 200 R0001 1SAP 424 200 R0001 CI542-DP, PROFIBUS DP bus module,
More informationFlow measurement FlexFlow PF20S Flow sensor for industrial applications
Product highlights Parallel measurement of flow and temperature Flow measurement independent of the mounting position Large measuring range up to 400 cm/s Measurement at high media temperatures up to 125
More informationElectronic timer CT-EAS ON-delayed and OFF-delayed with 1 c/o contact Data sheet
2CDC 251 116 F0004 1 5 2 4 3 6 Characteristics Single-function ON-delay and OFF-delay timer One device includes 10 time ranges, from 0.05 s to 300 h, for the adjustment of the time delay Remote potentiometer
More information