1 DSTCAL Software User Manual 09/16/09 WD1037 Rev E Revised 09/09/14 Wahl Instruments, Inc. 234 Old Weaverville Road Asheville, NC Toll Free Phone Fax

2 Table of Contents 1. INTRODUCTION DSTCAL DSTCAL-Pro DSTCAL KIT INSTALLATION AND SETUP Kit Contents DSTCAL Software Installation Hardware Installation Driver Installation SCREEN DEFINITIONS RTD Models CALIBRATION RTD Models Theory of Calibration Meter Calibration Probe Calibration Error Windows SCREEN DEFINITIONS - DSX Models: CALIBRATION DSX Current Loop Theory of Calibration Current Loop Calibration DST600 PROBE ID Theory of Operation Definitions Probe Association SCREEN DEFINITIONS Thermocouple Models CALIBRATION Thermocouple Models Theory of Calibration Meter Calibration Cold Junction Compensation Calibration Window Page 2 of 24

3 1. INTRODUCTION This software package is for use with the DST400, DST/DSX500 and DST600 family of Digital Thermometers. There are 2 versions of software, one for customer use and one for use by the factory. The version is indicated on the first line under the Poll for Module button. The 2 versions are: 1.1. DSTCAL Allows the following: Setting of LCD Refresh (display update rate) for all models; R0 Value for all RTD models; Selection of Thermocouple Type for all Thermocouple models; Programming of the 4-mA value, 20-mA value and burnout selection on the DSX models; Association and enabling of probe ID s for DST600 series Models; Setting of Low Battery Check rate; Calibration of the meter s measurement electronics, resistance input for RTD models and mv input for T/C models; Calibration of the meter and probe using an ice bath for RTD versions; Calibration of the Cold Junction Compensation electronics for T/C versions; Calibration of the 4-20 ma output circuit for DSX models NOTE: This software does not calibrate the transmitter section of Models DST620 or DST621, which require the transmitter manufacturer s software and interface module DSTCAL-Pro Only available for the Wahl Factory, same as DSTCAL but also allows setting of the unit s serial number and setting of the Factory default calibration values. Page 3 of 24

4 2. DSTCAL KIT INSTALLATION AND SETUP 2.1. Kit Contents The DSTCAL Kit is delivered with a CD-ROM that includes the following files: Application files Autorun.inf DSTCAL.application Setup.exe WD1035 DSTCAL Load Instructions WD1037 DSTCAL User Manual The DSTCAL kit also includes: P/N Description Cable, USB2.0A to Mini-B, 5 pin, 6 Ft. DST/USB Interface Module Cable, DST/13506 Interface, 4 pin 2.2. DSTCAL Software Installation 1. Install DSTCAL CD-ROM into the computers CD drive and the AutoPlay window should pop up. 2. Click on Run setup.exe 3. Follow the on-screen prompts Hardware Installation 1. Connect the cable, with the USB2.0A end to your PC s USB port and the Mini-B connector to the USB port on the DST/USB Interface Module. 2. Connect the 4 pin cable assembly, p/n 13507, to the DST/USB Interface Module port labeled DIGI-STEM. 3. With the Digi-Stem unit open, connect the opposite end of the cable to J3 on the back of the PCB assembly with the RED wire going to Pin 1. Pin 1 is marked on the PCB and is the pin closest to the blue jumper for the C/ F switch Driver Installation Once the software is loaded and the hardware is connected, your computer may report that it needs a driver for the interface box. Usually, the automatic driver search window will find it. If not, you can manually load the driver by: 1. Open your web browser and go to 2. On the left hand menu, click on Drivers, and then click on the sub menu of VCP Drivers. 3. Scroll down to the table labeled Currently supported VCP Drivers: 4. Find your operating system, such as Windows X86 (32-bit) and click on the version in the table, ie Follow the auto install wizard. 6. Close the web browser. Page 4 of 24

5 3. SCREEN DEFINITIONS RTD Models Wahl DST/DSX Series Calibration Software (vx.x.x.xx) window; reference Fig. 1. Note: Rolling the mouse indicator over a title or box will show additional information on the specific subject. File: Activation This command allows entry of the Activation Key to change between versions. User installation installs the DSTCAL version. Key for DSTCAL-Pro is only available for the factory. Check for updates Checks the Wahl Instruments website ( to see if there are updates available and reports status of your software. Software will prompt you to download new software if it is available. Exit Closes the Calibration Software Settings: Fahrenheit / Celsius - Selects Fahrenheit or Celsius as the temperature scale to be used when programming the 4 ma and 20 ma values (DSX models only). SPY COM - Serial Communication Debug Tool. Not used during normal operation. Help: About Displays software version and contact information for Wahl Instruments. Select OK to close. Poll for Module: This button is used to establish communication between the PC and the Instrument being programmed/calibrated. In some cases, it may need to be clicked multiple times, but usually no more than three. Select COM Port: This button opens the COM port selection window. This is used to select the proper COM port. If the COM port the module is connected to does not show, click Refresh then Scan All COM Ports. Highlight the COM port and click OK. Module Configuration Information Module settings for S/N : Identifies serial number of instrument. Size: Size of the configuration data in bytes. Model: Identifies instruments model number currently connected to DSTCAL software. Firmware Revision: Identifies firmware revision of instrument. Build Date: Identifies date firmware was compiled. Page 5 of 24

6 Build Time: Identifies time firmware was compiled. Hardware Revision: Identifies Hardware revision level. This parameter is hard coded into firmware. Serial number: Identifies serial number of PCB, programmable on DSTCAL-Pro only. LCD Refresh: Sets update period for the LCD. 1 period = 250 ms, thus, LCD Refresh: 2 = 500 ms or 0.5 second update rate for LCD. Default value is 8. LCD Refresh is not available for model DST550, which is hard programmed for sample intervals. Low Battery Check: Sets update period for checking of low battery. 1 period = 250 ms, thus Low Battery Check: 1200 = 300,000 ms or 5 minute interval for battery checking. Calibration Information Module Calibration Data RTD Models Active Rref Resistance of nominal 248 ohm reference resistor as calculated by measurements during the Ohm Meter Calibration process. Active Roffset Offset value for reference resistor as calculated by measurements during the Ohm Meter Calibration process. R0 Resistance at 0.0 C. R0 value is used for calculating temperature from the measured resistance. For the highest accuracy of measurements, it should be set to match the R0 value of the probe being used. It may be manually entered or may be automatically calculated and updated by performing Probe (system) Calibration. Box will turn red if value is out of acceptable range of 100 ± 10 ohms. Select Calibration to Perform: The Drop down box allows the user to select one of two calibration routines. To select, simply highlight the desired routine and click the Calibrate button. A calibration routine with step by step instructions will take you through the calibration process. See DSX section for DSX current loop calibration instructions. 1) Ohm Meter Calibration Performs the calibration of the Electronics to ensure it accurately measures resistance. This routine requires the use of known precision resistances. A precision resistor decade box or precision fixed resistors may be used. Some electronic RTD simulators may also work, but we recommend validating their use with the Digistem prior to using them for calibration. R0 will automatically be set to ohms for this calibration and upon completion, the user will be given the option to return to the initial R0 or leave it at ohms. Page 6 of 24

7 2) Probe (system) Calibration Performs the calibration of the RTD probe to the meter electronics. This method can be performed when equipment to measure the probes R0 value is not available. This should not be performed if the R0 value is manually entered into the R0 field. Existing Meter Calibration Settings Factory These settings are the default settings and can only be set at the factory. Active These settings are the calibration coefficients used in calculating temperature from the measured probe resistance. These may be changed by the user via the Ohm Meter Calibration routine. Restore Factory Settings This button loads the Active settings registers with the current values displayed under the Factory settings. This is used in the event the Active settings have been corrupted by invalid calibration. NOTE: Restoring the Factory settings will cause the current active settings to be deleted. A new calibration will need to be performed if new Active settings need to be acquired. Showing info box when mouse is over LCD Refresh: title. Fig. 1 Page 7 of 24

8 4. CALIBRATION RTD Models 4.1. Theory of Calibration With respect to calibration, the RTD thermometer can be viewed as two independent systems with different calibration requirements. The first system is comprised of the meter electronics. The meter calibration is performed so that the meter will measure resistance accurately. This is accomplished by using known, fixed resistances of a specified accuracy. Wahl recommends using resistances with a known accuracy equal to or greater than ±0.009 ohms. The calibration routine also allows entry of the exact resistance. This will allow the technician to enter the calibrated resistor value from a NIST traceable laboratory data sheet or by measuring a nominal valued resistance with a precision ohmmeter, such as an HP3458A, and entering the measured value. See METER CALIBRATION below for details. The second system is the addition of a specific probe to the meter. Due to manufacturing processes, there are variations in the RTD s R0 coefficient. To increase the total system accuracy, the electronics may be programmed with this value so that the microprocessor can accurately calculate the actual temperature from the measured resistance. See PROBE CALIBRATION below for details Meter Calibration Ohm Meter Calibration Window Selecting Resistance Screen 1. Sets R0 to 100 ohms in the event it is set otherwise. 2. Prompts user to Connect 50 ohm Standard Resistance to Meter Input (90 ohm for DST600 series), user may optionally enter exact value of Resistance into the Measured Resistance box. Box will turn red if value is out of acceptable range. 3. Click Next to continue (Clicking Cancel will return to main screen). Waiting for Stabilization Screen 4. Unit waits 10 seconds for stabilization of capacitors Averaging Samples Screen 5. Unit takes 10 readings to average for calibration Selecting Resistance Screen 6. Prompts user to Connect 280 ohm Standard Resistance to Meter Input (194.1 ohm for DST600 series), user may optionally enter exact value of Resistance into the Measured Resistance box. 7. Click Next to continue (Clicking Cancel will return to main screen). Waiting for Stabilization Screen 8. Unit waits 10 seconds for stabilization of capacitors Page 8 of 24

9 Averaging Samples Screen 9. Unit takes 10 readings to average for calibration Finalizing Calibration Screen 10. Displays results of calibration 11. Click Set Calibration to continue (Clicking Cancel will return to main screen). Set Active Calibration? Window 12. Do you wish to calibrate the module with the values below? Set Active calibration pair to: (xxx.xxxx, x.xxxx) 13. Click Yes to continue. Clicking No will return to Finalizing Calibration Screen. Pro version will send to Set Factory Calibration? window, below. Set Factory Calibration? Window (DSTCAL-Pro only) 14. Do you wish to calibrate the module with the values below? Set Factory calibration pair to: (xxx.xxxx, x.xxxx) 15. Click Yes to continue or No to return to Finalizing Calibration Screen Meter Calibration Success Window 16. One of the following 3 messages will be displayed, depending on previous choices: A meter calibration was performed successfully on this module. Both Active and Factory calibration set to: (xxx.xxxx, -x.xxxxxx) A meter calibration was performed successfully on this module. Only Active calibration set to: (xxx.xxxx, -x.xxxxxx) A meter calibration was performed successfully on this module. Only Factory calibration set to: (xxx.xxxx, -x.xxxxxx) 17. Click OK. Program displays the following message: Page 9 of 24

10 Press yes to return R0 to its original value or press no to leave R0 set to ohms Probe Calibration There are two methods of calibrating the probe to the meter. The first method is done without the aid of the Probe (system) Calibration routine found under the Select Calibration to Perform window. For this method, a precision 4-wire ohmmeter is required. The second method can be used if a precision 4-wire ohmmeter is not available. Probe with Precision 4-wire Ohmmeter Calibration 1. Insert the probe (disconnected from the Digistem) into an ice bath and allow it to stabilize. 2. Measure its resistance with a precision 4-wire ohmmeter. 3. Enter the measured resistance value into the R0 field of the Calibration software. 4. Click the SET button. Probe without Precision 4-wire Ohmmeter Calibration - Probe (system) Calibration Window 1. Click on the Select Calibration to Perform drop down box, and select Probe (system) Calibration 2. Click the Calibrate button 3. Placing probe in Ice Bath window will open. Place probe in Ice Bath and allow to stabilize. 4. Click Next button. (Click Cancel to abort the calibration) 5. Waiting for stabilization window will appear for 10 seconds, followed by Averaging Samples window. When the sample count gets to 10 the Capture R0 button will become active. The software continues to collect samples at approximately once per second and displays a running average of the most recent 10 samples. This allows the user to verify the probe has stabilized in the ice bath. 6. When the probe stability is acceptable, click Capture R0. 7. Capture R0 window will appear asking if you wish to use this value for R0. Click Yes to capture or No to return to the Averaging samples window. The unit will continue to collect samples and display them. You may re-capture R0 or Cancel to exit the program. Page 10 of 24

11 8. Software will display Probe Calibration Success window. 9. Click OK 10. Software will return to main screen and new value will be loaded into the R0 register and window Error Windows The following error box may occur when in the Meter Only Calibration routine and if the input resistance is not within approximately 4 ohms of the requested nominal setting. One or both of the following error messages may occur when in the Meter Only Calibration and the calculated calibration values don t meet the expected results. The most likely cause of this is that the resistances applied were not equal to the specified resistance or the resistance was changed during the calibration measurements. This may be corrected by entering the actual resistance of the standard used. Page 11 of 24

12 5. SCREEN DEFINITIONS - DSX Models: Additionally to the previous standard definitions the DSX model software contains the following, reference Fig. 2: Module Configuration Information Module settings for S/N xxxxxxxx: 4 ma Temp. ( C): 0.0: Shows the equivalent current setting for the 4-mA output in F or C. Temperature scale is changed under the Settings menu. The 4-mA value must be a minimum of 10 C (18 F) below the 20-mA setting. 20 ma Temp. ( C): 100.0: Shows the current setting for the 20-mA output in F or C. Temperature scale is changed under the Settings menu. The 20-mA value must be a minimum of 10 C (18 F) above the 4-mA setting. Burnout Setting: 22.0 Upscale (22.0 ma): User selectable setting for fault indication to drive the current to a low or high setting in the event a sensor gets disconnected, or opens. The current values are selected to comply with the NAMUR recommendation NE43 ( ). The two settings available from the drop down menu are: Upscale (22.0 ma) drives the current to 22.0 ma if fault is detected. Downscale (3.5 ma) drives the current to 3.5 ma if fault is detected. Calibration Information Module Calibration Data 4-20 ma Cal. Slope: Displays slope correction for D/A converter ma Cal. Offset: Displays offset correction for D/A converter. Select Calibration to Perform: For DSX models, there is a third option on the Select Calibration to Perform drop down box that allows the user to perform calibration of the current loop output. Select the 4-20 ma Calibration and click the Calibrate button. A calibration routine with step by step instructions will take you through the calibration process ma Calibration Performs calibration of the electronics for the 4-20 ma current output. This calibration requires a precision current meter with resolution of 1 microamp or less. Page 12 of 24

13 Fig. 2 Page 13 of 24

14 6. CALIBRATION DSX Current Loop 6.1. Theory of Calibration Calibration of the 4-20 ma current loop is performed by selecting the 4-20 ma Calibration on the drop down menu and following the on-screen prompts. This routine performs calibration of the absolute current. It is not intended to make adjustments for temperature to current equivalency. The Module Settings portion of Module Configuration Information should be used for temperature assignments Current Loop Calibration 4-20 ma Calibration Window Enter Measured Current (~4 ma) Screen 1. Forces DSX unit to output 4 ma signal and prompts user to enter actual value measured on precision DC current meter. Box will turn red if value is out of acceptable range. 2. Click Next to continue or Cancel to abort. Enter Measured Current (~20 ma) Screen 3. Forces DSX unit to output 20 ma signal and prompts user to enter actual value measured on precision DC current meter. Box will turn red if value is out of acceptable range. 4. Click Next to continue or Cancel to abort. Verify Output Current Screen 5. Forces unit to output 20 ma. Prompts user to verify the output current using a precision DC current meter. 6. Click Yes if current is within ±.002 ma and calibration will be complete with new coefficients being loaded into registers. 7. Click No if current is not within ±.002 ma and routine will restart to perform calibration again. If the error is greater than.002 ma we suggest running the calibration routine again. Typing a wrong value in one of the windows is a likely cause of error. In the event the unit cannot be calibrated, please contact the factory. Page 14 of 24

15 7. DST600 PROBE ID 7.1. Theory of Operation Probe ID allows a specific probe to be associated with a specific meter. The meter will only display a temperature when it has the correct probe connected to it. The primary reason for this association is that in case of a failed probe, it helps prevent someone from replacing the probe without going through a calibration process. The unit will display Prb indicating an unauthorized probe is being used. To authorize a new probe, the unit must be connected to the programming or calibration software, where it is recommended the unit be recalibrated to ensure accuracy. The Probe ID may be overridden using the Enable Probe ID field. When the box is checked, the probe ID will function normally. Unchecked will disable the feature. Due to the technology used, on remote cables with connectors the Probe ID has a limit of about 28 meters (92 feet) maximum cable length. Fig Definitions (Reference Fig. 3) Additionally to the previous standard definitions, the DST600 software contains the following information for Probe ID: Page 15 of 24

16 Module Calibration Data Probe ID: 0536B Displays serial number of current probe with which the module is associated. Enable Probe ID: Not Enabled Shows current status of Probe ID Enable Probe ID Capture Probe - Used to associate a new probe with the DST Probe Association Upon connecting a unit to the pc and starting the software the unit is connected via the Poll for Module button. If the probe connected to the unit is not the one associated with the DST600 the following screen will appear: Clicking OK will close this window. To associate the new probe, click the Capture Probe button (Fig. 3). The following screen will appear: To associate the new probe, clicks yes, otherwise click no and the current probe will remain associated. Upon association of the new probe, the DST600 display should change from Prb to the current temperature being measured by the probe within a few seconds. Page 16 of 24

17 8. SCREEN DEFINITIONS Thermocouple Models Wahl DST/DSX Series Calibration Software (vx.x.x.xx) window Note: Rolling the mouse indicator over a title or box will show additional information on the specific subject. Reference Fig. 4. File: Activation This command allows entry of the Activation Key to change between versions. User installation installs the DSTCAL version. Key for DSTCAL-Pro is only available for the factory. Check for updates Checks the Wahl Instruments website ( to see if there are updates available and reports status of your software. Software will prompt you to download new software if it is available. Exit Closes the Calibration Software Settings: Fahrenheit / Celsius - Selects Fahrenheit or Celsius as the temperature scale to be used when programming the 4 ma and 20 ma values (DSX models only- currently not available on 400 series). Help: About Displays software version and contact information for Wahl Instruments. Select OK to close. Poll for Module: This button is used to establish communication between the PC and the Instrument being programmed/calibrated. In some cases, it may need to be clicked multiple times, but usually no more than three. Select COM Port: This button opens the COM port selection window. This is used to select the proper COM port. If the COM port the module is connected to does not show, click Refresh then Scan All COM Ports. Highlight the COM port and click OK. Module Configuration Information Module settings for S/N : Identifies serial number of instrument. Size: Size of the configuration data in bytes. Model: Identifies instruments model number currently connected to DSTCAL software. Page 17 of 24

18 Firmware Revision: Identifies firmware revision of instrument. Build Date: Identifies date firmware was compiled. Build Time: Identifies time firmware was compiled. Hardware Revision: Identifies Hardware revision level. This parameter is hard coded into firmware. Serial number: Identifies serial number of PCB, programmable on DSTCAL-Pro only. LCD Refresh: Sets update period for the LCD. 1 period = 250 ms, thus, LCD Refresh: 2 = 500 ms or 0.5 second update rate for LCD. Default value is 8. Low Battery Check: Sets update period for checking of low battery. 1 period = 250 ms, thus Low Battery Check: 1200 = 300,000 ms or 5 minute interval for battery checking. Thermocouple Type Allows selection of J, K, E, T or S thermocouples. Changing of the thermocouple type requires the recalibration of the Cold Junction Compensation using the newly selected thermocouple type cable and input source. See section XXXX for instructions. Selection will display the following Caution: Calibration Information Thermocouple Models Module Calibration Data Thermocouple Models mv Cal. Slope Slope correction value for millivolt measurement as calculated by measurements during the Millivolt Calibration process. Displays active values used for the measurement. mv Cal. Offset Offset correction value for millivolt measurement as calculated by measurements during the Millivolt Calibration process. Displays active values used for the measurement. Select Calibration to Perform: Page 18 of 24

19 Millivolt Calibration: Used to calibrate the mv measurement capabilities of the meter. This is performed by inserting known millivolt signals via copper wires to the DST400 input connector. If this calibration is going to be performed, it must be performed before the Cold Junction Calibration, as Millivolt Calibration will alter the Cold Junction Calibration. Cold Junction Calibration: Used to calibrate the Cold Junction Compensation correction for a given thermocouple type. This is performed by using a Thermocouple Simulator to insert a 25 C equivalent signal, via thermocouple wire of the selected type, to the DST400 input connector. This calibration must be performed after changing thermocouple type. Existing Thermocouple Calibration Settings Factory These settings are the default settings and can only be set at the factory. Restore Factory Settings This button loads the Active settings registers with the current values displayed under the Factory settings. This is used in the event the Active settings have been corrupted by invalid calibration. NOTE: Restoring the Factory settings will cause the current active settings to be deleted. A new calibration will need to be performed if new Active settings need to be acquired. Showing info box when mouse is over LCD Refresh: title. Fig. 4 Page 19 of 24

20 9. CALIBRATION Thermocouple Models 9.1. Theory of Calibration Meter Calibration is performed to ensure that the meter will measure mv signals accurately. This is accomplished by using known, DC millivolt signals of a specified accuracy. Wahl recommends using mv signal generators with a known accuracy equal to or better than ± 6.0µV and thermocouple emissions of ±0.30 C (includes CJC) at 25 C. The calibration routine also allows entry of the exact millivolt signal. This will allow the technician to enter the calibrated mv value from a NIST traceable laboratory data sheet or by measuring a less accurate mv signal with a precision voltmeter, such as an Agilent 3458A, and entering the measured value. See METER CALIBRATION below for details. Cold Junction Compensation (CJC) Calibration is required to calibrate the cold junction circuit to provide the proper amount of correction for the specific thermocouple type being used. It is essential that this calibration be performed after changing the meter s thermocouple type. While the millivolt calibration is performed with copper wire connected to the meter, the CJC calibration must be performed with the specific thermocouple type wire. The correction factor used by the meter is the mv equivalent of the temperature offset measured in accordance with the selected thermocouple type s mv to temperature table Meter Calibration mv Meter Calibration Window Selecting Millivolt Screen 1. Prompts user to Connect 0 Millivolt Standard to Meter Input, user may optionally enter exact value of millivolt signal into the Measured Millivolts (mv) box. 2. Click Next to continue (Clicking Cancel will return to main screen). Waiting for Stabilization Screen 3. Unit waits 10 seconds for stabilization of capacitors Averaging Samples Screen 4. Unit takes 10 readings to average for calibration Selecting Millivolt Screen 5. Prompts user to Connect 75 Millivolt Standard to Meter Input, user may optionally enter exact value of millivolt signal into the Measured Millivolts (mv) box. 6. Click Next to continue (Clicking Cancel will return to main screen). Note: When performing the Millivolt Calibration, during the calibration of the 75mV, on occasion the calibrated value will show as the maximum mv value of mv. If this occurs, the unit is at its maximum value and may show inaccuracy at higher temperatures. To remedy this potential problem, simply recalibrate the unit and when DSTCAL prompts you to input 75mV, set the mv source to 74.0mV and type 74.0 into the DSTCAL window for the actual value entered. This will likely correct the problem. Page 20 of 24

21 Waiting for Stabilization Screen 7. Unit waits 1 second for stabilization of capacitors Averaging Samples Screen 8. Unit takes 10 readings to average for calibration Finalizing Calibration Screen 9. Displays results of calibration 10. Click Set Calibration to continue (Clicking Cancel will return to main screen). Set Active Calibration? Window 11. Do you wish to calibrate the module with the values below? Set Active calibration pair to: (xxx.xxxx, x.xxxx) 12. Click Yes to continue. Clicking No will return to Finalizing Calibration Screen. Pro version will send to Set Factory Calibration? window, below. Set Factory Calibration? Window (DSTCAL-Pro only) 13. Do you wish to calibrate the module with the values below? Set Factory calibration pair to: (xxx.xxxx, x.xxxx) 14. Click Yes to continue or No to return to Finalizing Calibration Screen Meter Calibration Success Window 15. One of the following 3 messages will be displayed, depending on previous choices: A meter calibration was performed successfully on this module. Both Active and Factory calibration set to: (xxx.xxxx, -x.xxxxxx) A meter calibration was performed successfully on this module. Only Active calibration set to: (xxx.xxxx, -x.xxxxxx) A meter calibration was performed successfully on this module. Only Factory calibration set to: (xxx.xxxx, -x.xxxxxx) 16. Click OK. Program displays the following message: Page 21 of 24

22 9.3. Cold Junction Compensation Calibration Window Selecting Standard Thermocouple Input Screen 1. Prompts user to Connect appropriate Thermocouple Standard to Meter Input. This must be with the same type of wire as the DST4xx meter is set to, ie. if meter is set to Type K, you must use Type K wire. Wire can be any limits of error and standard or extension grade. 2. Prompts user to set thermocouple standard s output to 25 C, user may optionally enter exact value of measured temperature signal into the Measured Temperature ( C) box. Waiting for Stabilization Screen 3. Unit waits one second for stabilization of capacitors. Averaging Samples Screen 4. Unit takes 10 readings to average for calibration. Finalizing Calibration Screen 5. Displays results of calibration 6. Click Set Calibration to continue (Clicking Cancel will return to main screen). Set Active Calibration? Window 7. Do you wish to calibrate the module with the values below? Set Active calibration to: (x.xxxxxx mv) 8. Click Yes to continue. Clicking No will return to Finalizing Calibration Screen. Pro version will send to Set Factory Calibration? window, below. Set Factory Calibration? Window (DSTCAL-Pro only) 9. Do you wish to calibrate the module with the values below? Set Factory calibration to: (x.xxxxxx mv) 10. Click Yes to continue or No to return to Finalizing Calibration Screen Meter Calibration Success Window 11. One of the following 3 messages will be displayed, depending on previous choices: A meter calibration was performed successfully on this module. Both Active and Factory calibration set to: (x.xxxxxx mv) A meter calibration was performed successfully on this module. Only Active calibration set to: (x.xxxxxx mv) Page 22 of 24

23 A meter calibration was performed successfully on this module. Only Factory calibration set to: (x.xxxxxx mv) 12. Click OK. Program displays the following message: Page 23 of 24

24 234 Old Weaverville Road, Asheville, NC Page 24 of 24

DST550 Digi-Stem Thermometer

DST550 Digi-Stem Thermometer DST550 Digi-Stem Thermometer User Manual 09/16/09 WD1045 Rev C Wahl Instruments, Inc. 234 Old Weaverville Road Asheville, NC 28804 Toll Free 800-421-2853 Phone 828-658-3131 Fax 828-658-0728 www.palmerwahl.com

More information

Digi-Stem Digital Temperature Indicating Devices for Food Processing

Digi-Stem Digital Temperature Indicating Devices for Food Processing Digi-Stem Digital Temperature Indicating Devices for Food Processing and other temperature crtical applications Exclusive Continuous Self- Checking Technology Trustworthy Alternative to Mercury-in-Glass

More information

L200 User Manual. Operating Instructions for L200-TC & L200-PT Temperature Monitor. RoHS compliant

L200 User Manual. Operating Instructions for L200-TC & L200-PT Temperature Monitor. RoHS compliant L200 User Manual Operating Instructions for L200-TC & L200-PT Temperature Monitor RoHS compliant Contents 1. About the L200................................................................... 3 2. Installation.......................................................................

More information

M3S Series Super-space-saving Signal Conditioners. PC CONFIGURATOR SOFTWARE Model: M3SCFG. Users Manual

M3S Series Super-space-saving Signal Conditioners. PC CONFIGURATOR SOFTWARE Model: M3SCFG. Users Manual M3S Series Super-space-saving Signal Conditioners PC CONFIGURATOR SOFTWARE Model: M3SCFG Users Manual 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN Tel: +81-6-6659-8201 Fax: +81-6-6659-8510

More information

DST600. Digi-Stem Digital RTD Reference Thermometer for Retorts & Temperature Critical Applications. Exclusive Continuous Self-Checking Technology

DST600. Digi-Stem Digital RTD Reference Thermometer for Retorts & Temperature Critical Applications. Exclusive Continuous Self-Checking Technology Actual Size Exclusive Continuous Self-Checking Technology Trustworthy Alternative to Mercury-in-Glass Designed in compliance with the FDA Final Rule Change for 21 CFR Part 113 Digi-Stem Digital RTD Reference

More information

PC CONFIGURATOR Model: 27HUCFG. Users Manual , Minamitsumori, Nishinari-ku, Osaka JAPAN Tel: Fax:

PC CONFIGURATOR Model: 27HUCFG. Users Manual , Minamitsumori, Nishinari-ku, Osaka JAPAN Tel: Fax: Model 27HU Universal Temperature Transmitter PC CONFIGURATOR Model: 27HUCFG Users Manual 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN Tel: +81-6-6659-8201 Fax: +81-6-6659-8510 http://www.m-system.co.jp/

More information

Model B3HU. PC CONFIGURATOR Model: B3HUCFG. Users Manual

Model B3HU. PC CONFIGURATOR Model: B3HUCFG. Users Manual Model B3HU PC CONFIGURATOR Model: B3HUCFG Users Manual 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN Tel: +81-6-6659-8201 Fax: +81-6-6659-8510 http://www.m-system.co.jp/ E-mail: info@m-system.co.jp

More information

Specification for temperature sensor calibration setup

Specification for temperature sensor calibration setup 1. Item description Automated Temperature calibration setup made of: A. High accuracy temperature bath with internal and external reference probe, multiple sensors insert kits, carry case and other accessories.

More information

For 2-wire Universal Temperature Transmitter B6U. PC CONFIGURATOR Model: B6UCFG. Users Manual

For 2-wire Universal Temperature Transmitter B6U. PC CONFIGURATOR Model: B6UCFG. Users Manual For 2-wire Universal Temperature Transmitter B6U PC CONFIGURATOR Model: B6UCFG Users Manual 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN Tel: +81-6-6659-8201 Fax: +81-6-6659-8510 http://www.m-system.co.jp/

More information

PIECAL 322 Automated Thermocouple Calibrator Operating Instructions. Product Description. Practical Instrument Electronics

PIECAL 322 Automated Thermocouple Calibrator Operating Instructions. Product Description. Practical Instrument Electronics PIECAL 322 Automated Thermocouple Calibrator Operating Instructions Product Description Easy to use With the PIECAL 322-1 you can check & calibrate all your thermocouple instruments and measure thermocouple

More information

-auto Power Off- T1/T2/T1-T2

-auto Power Off- T1/T2/T1-T2 -auto Power Off- T1/T2/T1-T2 CONTENTS 1. Safety Information...1 2. Product Overview...3 3. Recognize Meter..... 4 3.1 Component...4 3.2 Display...5 3.3 Keys Description...6 4. Setting Meter...8 4.1 SETUP

More information

DST600. Digi-Stem Digital RTD Reference Thermometer for Retorts & Temperature Critical Applications

DST600. Digi-Stem Digital RTD Reference Thermometer for Retorts & Temperature Critical Applications Actual Size Exclusive Patent- Pending Wahl Continuous Self- Checking Technology Trustworthy Alternative to Mercury-in-Glass Designed in compliance with the FDA Final Rule Change for 21 CFR Part 113 Digi-Stem

More information

WARNING: Do not use the thermometer/data logger before you read the users manual and the following instructions.

WARNING: Do not use the thermometer/data logger before you read the users manual and the following instructions. 55 This unit passes the following tests EN 61326-1:2006 (CISPR11,IEC/EN 61000-3-2:2006, IEC/EN 61000-3-3: 1995+A1 :2001+A2:2005 IEC/EN 61000-4-2/-3/-5/-6/-11) WARNING: Do not use the thermometer/data logger

More information

Professional Thermocouple Thermometer with Four Type K Inputs, Data Logging, and Optional Infrared Wand

Professional Thermocouple Thermometer with Four Type K Inputs, Data Logging, and Optional Infrared Wand User Manual Professional Thermocouple Thermometer with Four Type K Inputs, Data Logging, and Optional Infrared Wand with NIST-Traceable Calibration Model 20250-20 Enter REC DIF THE STANDARD IN PRECISION

More information

ACT20X-(2)HTI-(2)SAO Temperature/mA converter. Safety Manual

ACT20X-(2)HTI-(2)SAO Temperature/mA converter. Safety Manual ACT20X-(2)HTI-(2)SAO Temperature/mA converter Safety Manual 1.1 Revision history Version Date Change 00 04/2014 First Edition 01 11/2017 Products added 1.2 Validity This manual is valid for the following

More information

DIGI-STEM. Thermometer and Transmitter Systems

DIGI-STEM. Thermometer and Transmitter Systems DIGI-STEM DIGI-STEM Thermometer and Transmitter Systems Measure Process Temperatures with Digital Accuracy Rigid & Remote Sensor Systems RTD or Thermocouple Output PW1200 www.palmerwahl.com ISO 9001:2000

More information

TC2100 HOLD MAX AVG MIN SETUP THERMOMETER. K T1-T2 F C mv TYPE KJTERSN USB MAX MIN AVG MEN. K INTERVAL hour:min POWER T1 T2.

TC2100 HOLD MAX AVG MIN SETUP THERMOMETER. K T1-T2 F C mv TYPE KJTERSN USB MAX MIN AVG MEN. K INTERVAL hour:min POWER T1 T2. OFFSET SETUP READ REC HOLD TC2100 Digital Thermometer User s Manual T1 T2 K T1-T2 F C mv TYPE KJTERSN USB MAX MIN AVG MEN K INTERVAL hour:min T1 T2 : F CAL min:sec C POWER MAX AVG MIN HOLD SETUP THERMOMETER

More information

1523/1524 Reference Thermometers

1523/1524 Reference Thermometers 1523/1524 Reference Thermometers Measure, graph and record three sensor types with one tool High accuracy PRTs: up to ± 0.011 C Thermocouples: up to ± 0.24 C Precision thermistors: ± 0.002 C Two models

More information

User Manual. Thermocouple Thermometer with Dual Type K/J Inputs and Data Logging. Model with NIST-Traceable Calibration

User Manual. Thermocouple Thermometer with Dual Type K/J Inputs and Data Logging. Model with NIST-Traceable Calibration User Manual Thermocouple Thermometer with Dual Type K/J Inputs and Data Logging with NIST-Traceable Calibration Model 20250-02 THE STANDARD IN PRECISION MEASUREMENT Introduction The Digi-Sense Thermocouple

More information

FIELD CALIBRATION PROCEDURE FOR ALTEK MODEL 222A

FIELD CALIBRATION PROCEDURE FOR ALTEK MODEL 222A FIELD CALIBRATION PROCEDURE FOR ALTEK MODEL 222A DRAWING NO. 1-827 Date Rev. Revision Record Dr. Review Approve 8FEB94 A Initial Release DJN PBG RPC 25AUG98 B Corrected Specifications DJN AC RPC 26AUG98

More information

Create a worksheet that collects, displays and saves temperature data

Create a worksheet that collects, displays and saves temperature data DASYLab Techniques Create a worksheet that collects, displays and saves temperature data This document describes how to create a worksheet that acquires and processes temperature data using Measurement

More information

Fox Thermal Instruments, Inc.

Fox Thermal Instruments, Inc. Fox Thermal Instruments, Inc. THERMAL MASS FLOW METER & TEMPERATURE TRANSMITTER FT3 View www.foxthermalinstruments.com 399 Reservation Road Marina, CA. 93933 104845 Rev. D Notice FOX THERMAL INSTRUMENTS

More information

FT2 View Instruction Manual

FT2 View Instruction Manual 399 Reservation Road, Marina, California U.S.A. Ph: (831) 384-4300 Fax: (831) 337-5786 www.foxthermalinstruments.com 2006 Fox Thermal Instruments, Inc. 07/19/13 Introduction: The FT2 View application software

More information

Model 620A Maintenance and Calibration

Model 620A Maintenance and Calibration Model 0A Maintenance and Calibration CAUTION! See Ch Pg, A & B below prior to connecting inputs to TB of the A PCB. Determine Rev. of the A board on the Model 0/0A for correct input connections. Failure

More information

Digital Thermometer MEM. PC-Link READ

Digital Thermometer MEM. PC-Link READ Digital Thermometer MEM PC-Link READ CONTENTS Digital Thermometer 1. Safety Information...1 2. Product Overview...3 3. Recognize Meter..... 4 3.1 Component...4 3.2 Display...5 3.3 Keys Description...6

More information

DST500-FM Digi-Stem Thermometer User Manual

DST500-FM Digi-Stem Thermometer User Manual DST500-FM Digi-Stem Thermometer User Manual Intrinsically Safe - Sécurité Intrinsèque IS/CL I, II, III / DIV 1 / GP ABCDEFG; T4A Ta=70 C; Type 4X CL I, II, III / DIV 2 / GP ABCDEFG; T4A Ta=70 C; Type 4X

More information

High-Temp PRT Module 2561

High-Temp PRT Module 2561 3 The Black Stack Model 1560 Reads SPRTs, RTDs, thermistors, and thermocouples Any configuration you like up to eight modules High-accuracy reference thermometer (to ±0.0013 C) Automates precision data

More information

ASM Series. Advanced Signal Multi-scanner. Functional signal multi-scanner adding flexibility to your calibration needs

ASM Series. Advanced Signal Multi-scanner. Functional signal multi-scanner adding flexibility to your calibration needs 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-571-8431 signal Visit us at www.testequipmentdepot.com ASM Series Advanced Signal Multi-scanner Functional signal multi-scanner

More information

Safety. 2. Configuration - Operation 2.1 RTD Selection 2.2 Driver Test Header. 3. Diagnostics 3.1 ph Input 3.2 Temperature Input

Safety. 2. Configuration - Operation 2.1 RTD Selection 2.2 Driver Test Header. 3. Diagnostics 3.1 ph Input 3.2 Temperature Input Safety 1. Installation 1.1 PT:Services 1.2 erature Compensation of 1.3 Controller Services 1.4 Driver Card Installation 1.5 Sensor Part Numbers 1.6 Sensor Wiring 2. Configuration - Operation 2.1 Selection

More information

Portable Multi-Function Calibrator Model CEP6000

Portable Multi-Function Calibrator Model CEP6000 Calibration Technology Portable Multi-Function Calibrator Model CEP6000 WIKA Data Sheet CT 83.01 Applications Calibration service companies/service industry Instrument and control workshops Industry (Laboratories,

More information

User Manual. Single-Input Thermometers. with NIST-Traceable Calibration. Thermocouple Meter, Type J/K/T Input Model

User Manual. Single-Input Thermometers. with NIST-Traceable Calibration. Thermocouple Meter, Type J/K/T Input Model User Manual 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Single-Input Thermometers with NIST-Traceable Calibration Thermocouple

More information

UNIVERSAL TEMPERATURE TRANSMITTER

UNIVERSAL TEMPERATURE TRANSMITTER UNIVERSAL INPUT, DUAL CHANNEL ATEX & IEC Ex Version MATHS FUNCTIONS SENSOR CHARACTERISTICS DOWNLOAD VIA USB PORT ALLOWS FOR CUSTOM TYPES FLASH TESTED TO 4 KV DC INTRODUCTION The SEM210 is a universal transmitter

More information

RTD-500 Precision RTD Simulator. Operations Manual.

RTD-500 Precision RTD Simulator. Operations Manual. RTD-500 Precision RTD Simulator Operations Manual. Page 1 of 16 Table of Content. Table of Content....1 1 Scope...3 2 Package Content....3 3 Technical Data....3 4 Preparation for use....4 4.1 Switching

More information

Field Metrology Wells

Field Metrology Wells 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Field Metrology Wells Technical Data Recently, we introduced Metrology Wells, which

More information

User Manual. Dual-Input Data Logging Thermometers. with NIST-Traceable Calibration. Thermocouple Meter, Type J/K/T Input Model

User Manual. Dual-Input Data Logging Thermometers. with NIST-Traceable Calibration. Thermocouple Meter, Type J/K/T Input Model User Manual Dual-Input Data Logging Thermometers with NIST-Traceable Calibration Thermocouple Meter, Type J/K/T Input Model 20250-92 Thermistor Meter Model 20250-94 RTD Meter Model 20250-96 THE STANDARD

More information

OBSOLETE. Isolated, Linearized, Thermocouple Input 3B47 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

OBSOLETE. Isolated, Linearized, Thermocouple Input 3B47 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM FEATURES Interfaces, amplifies, filters, isolates, & linearizes analog input voltages from a J, K, T, E, R, S or B-type thermocouple Thermocouple input signal is internally linearized High accuracy internal

More information

1523/1524. Reference Thermometers. Measure, graph and record three sensor types with one tool

1523/1524. Reference Thermometers. Measure, graph and record three sensor types with one tool 1523/1524 Reference Thermometers Measure, graph and record three sensor types with one tool Finally, a reference thermometer as versatile as you The 1523/24 Reference Thermometers from Fluke Calibration

More information

RADLINK V1.01. INSTALLATION and OPERATION

RADLINK V1.01. INSTALLATION and OPERATION RADLINK V1.01 INSTALLATION and OPERATION 01/2006 Table of Contents INTRODUCTION... 1 RADLink Software... 1 Host System Requirements... 1 INSTALLATION... 2 Equipment required... 2 RADLink Software Installation...

More information

HART UNIVERSAL TEMPERATURE TRANSMITTER

HART UNIVERSAL TEMPERATURE TRANSMITTER SEM310 / SEM310X HART 5,6,7 COMPATABLE UNIVERSAL INPUT, DUAL CHANNEL ATEX & IEC Ex Version MATHS FUNCTIONS SENSOR CHARACTERISTICS DOWNLOAD VIA USB PORT ALLOWS FOR CUSTOM TYPES FLASH TESTED TO 4 KV DC INTRODUCTION

More information

Temperature Measurement Instruments Ultra-Accurate... by Design

Temperature Measurement Instruments Ultra-Accurate... by Design TEMPpoint Type: Temperature Measurement Instrument Temperature Measurement Instruments Ultra-Accurate... by Design TEMPpoint is a family of temperature measurement instruments designed for high accuracy

More information

TRANSMITTER CONFIGURATION MANUAL

TRANSMITTER CONFIGURATION MANUAL Model 5030-881 TRANSMITTER CONFIGURATION MANUAL ACROMAG INCORPORATED 30765 South Wixom Road P.O. BOX 437 Wixom, MI 48393-7037 U.S.A. Tel: (248) 295-0880 Fax: (248) 624-9234 Email: sales@acromag.com Web:

More information

3001 Operator s Manual

3001 Operator s Manual 3001 Operator s Manual 3001 Operator s Manual 1. Introduction.........................................................1 1.1 Customer Service.......................................................1 1.2

More information

SEM310 SEM310X HART UNIVERSAL TEMPERATURE TRANSMITTER

SEM310 SEM310X HART UNIVERSAL TEMPERATURE TRANSMITTER HART 5,6,7 COMPATABLE UNIVERSAL INPUT, DUAL CHANNEL ATEX & IEC Ex Version MATHS FUNCTIONS FLASH TESTED TO 4 KV DC INTRODUCTION The SEM310 is a HART 5 upwards, (generic device) compatible universal transmitter.

More information

Field Metrology Wells

Field Metrology Wells Field Metrology Wells Technical Data Recently, we introduced Metrology Wells, which provide the very best performance in portable temperature calibration. The new 914X Series Field Metrology Wells extend

More information

User Manual. Single-Input Thermometers. with NIST-Traceable Calibration. Thermocouple Meter, Type J/K/T Input Model

User Manual. Single-Input Thermometers. with NIST-Traceable Calibration. Thermocouple Meter, Type J/K/T Input Model User Manual Single-Input Thermometers with NIST-Traceable Calibration Thermocouple Meter, Type J/K/T Input Model 20250-91 Thermistor Meter Model 20250-93 RTD Meter Model 20250-95 THE STANDARD IN PRECISION

More information

Model B6U / B6U-B PC CONFIGURATOR (model: B6UCON)

Model B6U / B6U-B PC CONFIGURATOR (model: B6UCON) Model B6U / B6U-B PC CONFIGURATOR (model: B6UCON) Users Manual Contents 1. GETTING STARTED... 2 1.1 HARDWARE REQUIREMENTS... 2 1.2 INSTALLING THE B6UCON... 2 1.3 STARTING UP THE B6UCON... 2 2. OPERATING

More information

Fox Thermal Instruments, Inc.

Fox Thermal Instruments, Inc. Fox Thermal Instruments, Inc. THERMAL MASS FLOW METER & TEMPERATURE TRANSMITTER FT2A View www.foxthermalinstruments.com 399 Reservation Road Marina, CA. 93933 105406 Rev. A Notice FOX THERMAL INSTRUMENTS

More information

C100 Portable Multifunction

C100 Portable Multifunction C100 Portable Multifunction Superior Accuracy as compared to Competitors! Wahl C100 Simultaneous Measurement and Generation Rugged IP54 Construction for On Site Use Quick Connect Terminals Measurement

More information

1. Introduction 2. Specifications 3. Symbol Definition and Button Location 4. Operation Instructions 5. Temperature Measurement 6.

1. Introduction 2. Specifications 3. Symbol Definition and Button Location 4. Operation Instructions 5. Temperature Measurement 6. CONTENTS TITLE PAGE 1. Introduction.. 1 2. Specifications... 1 3. Symbol Definition and Button Location... 2 4. Operation Instructions.... 3 4.1 Power-Up...3 4.2 Connection of the Temperature Probe...

More information

Scanner 2000 microefm QuickStart. Installing the Scanner Remote Mount. Direct Mount NUFLO. Part No , Rev. A

Scanner 2000 microefm QuickStart. Installing the Scanner Remote Mount. Direct Mount NUFLO. Part No , Rev. A NUFLO Part No. 30165024, Rev. A Scanner 2000 microefm QuickStart Installing the Scanner 2000 H L H L Flow Direct Mount To install the Scanner 2000 microefm using a direct mount to an orifice or cone meter

More information

HAND-HELD THERMOCOUPLE THERMOMETER SERVICE MANUAL. CATALOG NUMBERS , and , and PROPRIETARY

HAND-HELD THERMOCOUPLE THERMOMETER SERVICE MANUAL. CATALOG NUMBERS , and , and PROPRIETARY HAND-HELD THERMOCOUPLE THERMOMETER SERVICE MANUAL CATALOG NUMBERS 600-1000, 600-1010 and 600-1020 91100-00, 91100-10 and 91100-20 PROPRIETARY Information contained in this manual is proprietary to COLE-PARMER

More information

TC100 Precision Thermocouple Calibrator

TC100 Precision Thermocouple Calibrator TC100 Precision Thermocouple Calibrator Table of Contents 1. Introduction.....................1 2. Accessories....................5 3. Set-Up Basic/Advanced...........5 4. Operating Procedure.............6

More information

RST INSTRUMENTS LTD.

RST INSTRUMENTS LTD. RST INSTRUMENTS LTD. VW0420 Analog VW Interface Instruction Manual Ltd. 11545 Kingston St Maple Ridge, BC Canada V2X 0Z5 Tel: (604) 540-1100 Fax: (604) 540-1005 Email: Info@rstinstruments.com i VW0420

More information

AM3 Humidity. Temperature. Dew Point Indicator INSTRUCTION MANUAL

AM3 Humidity. Temperature. Dew Point Indicator INSTRUCTION MANUAL AM3 Humidity. Temperature. Dew Point Indicator INSTRUCTION MANUAL CONTENTS 1. Battery Operation... 3 2. Operation with a Rechargeable Battery... 3 3. Humidity and Temperature Probe (Probe Input 1)... 3

More information

User Manual Digi-Sense 12-Channel Benchtop Data Logging Thermocouple Thermometer

User Manual Digi-Sense 12-Channel Benchtop Data Logging Thermocouple Thermometer User Manual Digi-Sense 12-Channel Benchtop Data Logging Thermocouple Thermometer Model: 92000-01 THE STANDARD IN PRECISION MEASUREMENT Table of Contents Introduction... 3 Unpacking... 3 Initial Setup...3

More information

DIGI-STEM. Thermometer and Transmitter Systems

DIGI-STEM. Thermometer and Transmitter Systems DIGI-STEM DIGI-STEM Thermometer and Transmitter Systems Measure Process Temperatures with Digital Accuracy Rigid & Remote Sensor Systems RTD or Thermocouple Output PW1200 www.palmerwahl.com ISO 9001:2008

More information

User s Guide. CL3001 Lab Calibrator. Shop online at omega.com. For latest product manuals:

User s Guide. CL3001 Lab Calibrator. Shop online at omega.com.   For latest product manuals: User s Guide Shop online at omega.com e-mail: info@omega.com For latest product manuals: www.omegamanual.info NORWALK, CT CL3001 Lab Calibrator omega.com info@omega.com U.S.A. Headquarters: Servicing North

More information

USB Debug Adapter. Power USB DEBUG ADAPTER. Silicon Laboratories. Stop. Run. Figure 1. Hardware Setup using a USB Debug Adapter

USB Debug Adapter. Power USB DEBUG ADAPTER. Silicon Laboratories. Stop. Run. Figure 1. Hardware Setup using a USB Debug Adapter C8051F38X DEVELOPMENT KIT USER S GUIDE 1. Kit Contents The C8051F38x Development Kit contains the following items: C8051F380 Target Board C8051Fxxx Development Kit Quick-start Guide Silicon Laboratories

More information

PIECAL 520B & 521B Thermocouple Source Operating Instructions

PIECAL 520B & 521B Thermocouple Source Operating Instructions PIECAL 520B & 521B Thermocouple Source Operating Instructions (Shown without optional boot) Product Description (Shown with optional boot) Easy to use With the PIECAL 520B/521B you can check & calibrate

More information

MODEL 3150 SUSPENDED SOLIDS ANALYZER MODEL 35/35L OPTICAL SUSPENDED SOLIDS SENSOR

MODEL 3150 SUSPENDED SOLIDS ANALYZER MODEL 35/35L OPTICAL SUSPENDED SOLIDS SENSOR MODEL 3150 SUSPENDED SOLIDS ANALYZER MODEL 35/35L OPTICAL SUSPENDED SOLIDS SENSOR REVISION 15 May 2006 In site In strum e n tatio n Gro up, In c 80 Whisperwood Blvd. Suite 107 Slidell, LA 70458 Phone:

More information

3690 N.W. 53rd Street Fort Lauderdale, FL SC-2124 SC-2124M. 24 Channel Universal Scanner. Installation and Operation Manual P/N 145F-11902

3690 N.W. 53rd Street Fort Lauderdale, FL SC-2124 SC-2124M. 24 Channel Universal Scanner. Installation and Operation Manual P/N 145F-11902 3690 N.W. 53rd Street Fort Lauderdale, FL 33309 SC-2124 SC-2124M 24 Channel Universal Scanner Installation and Operation Manual P/N 145F-11902 Rev. 3.30 (c) Copyright 2000, Dynalco Controls All Rights

More information

DIGI-STEM. Thermometer and Transmitter Systems

DIGI-STEM. Thermometer and Transmitter Systems DIGI-STEM DIGI-STEM Thermometer and Transmitter Systems Measure Process Temperatures with Digital Accuracy Rigid & Remote Sensor Systems RTD or Thermocouple Output PW1200 www.palmerwahl.com ISO 9001:2008

More information

HART UNIVERSAL TEMPERATURE TRANSMITTER

HART UNIVERSAL TEMPERATURE TRANSMITTER SEM310 / SEM310X HART 5,6,7 COMPATABLE UNIVERSAL INPUT, DUAL CHANNEL ATEX & IEC Ex Version MATHS FUNCTIONS SENSOR CHARACTERISTICS DOWNLOAD VIA USB PORT ALLOWS FOR CUSTOM TYPES FLASH TESTED TO 4 KV A/C

More information

R1M-GH THERMOCOUPLE & DC INPUT MODULE MODEL. Remote I/O R1M Series. (16 points)

R1M-GH THERMOCOUPLE & DC INPUT MODULE MODEL. Remote I/O R1M Series. (16 points) Remote I/O R1M Series THERMOCOUPLE & DC INPUT MODULE (16 points) MODEL MODEL & SUFFIX CODE SELECTION R1MGH2T MODEL Modbus protocol I/O TYPE GH2 : Thermocouple or DC input, 16 points FIELD TERMINAL TYPE

More information

Probe Reader/ Calibration Programming Unit, PIU- 1 (#30010)

Probe Reader/ Calibration Programming Unit, PIU- 1 (#30010) Probe Reader/ Calibration Programming Unit, PIU- 1 (#30010) This product is designed to provide enhanced regulatory support for the Networked Robotics Tempurity System. The Tempurity System is designed

More information

MC1000 Multi-Function Calibrator

MC1000 Multi-Function Calibrator MC1000 Multi-Function Calibrator Table of Contents 1. Introduction 1.1 Customer Service................1 1.2 Standard Equipment..............1 1.3 Safety Information................2 2. Quick Start Instructions

More information

Evaluates: MAX MAX31856 Evaluation System. General Description. Features. EV System Contents. MAX31856 EV Kit Files. MAX31856 EV System Photo

Evaluates: MAX MAX31856 Evaluation System. General Description. Features. EV System Contents. MAX31856 EV Kit Files. MAX31856 EV System Photo General Description The MAX31856 evaluation system (EV system) provides the hardware and software necessary to evaluate the MAX31856 thermocouple-to-digital converter. The EV system includes the MAX31856PMB1

More information

Wiring guide for dual-output vibration and temperature sensors

Wiring guide for dual-output vibration and temperature sensors Wiring guide for dual-output vibration and temperature sensors Wilcoxon manufactures three types of sensors that output a vibration signal and a DC voltage proportional to the temperature. The temperature

More information

Can Speed: 1Mbps Base CAN ID: 0x0F0h TC8 Mode: 0 = E888 Serial Number: Checked By:

Can Speed: 1Mbps Base CAN ID: 0x0F0h TC8 Mode: 0 = E888 Serial Number: Checked By: Specification Document Number Title RG_SPEC-0024 8 Channel Thermocouple to CAN - TC8 Can Speed: 1Mbps Base CAN ID: 0x0F0h TC8 Mode: 0 = E888 Serial Number: Checked By: Firmware Revision Date Prepared By

More information

Created by: T.Tetreault Date:14jul 92 PAGE 1 OF 5

Created by: T.Tetreault Date:14jul 92 PAGE 1 OF 5 Rev Date Appd DCN B 7/14/92 RPC --- C 11/26/96 RPC --- D 26SEP00 TJT 10394 Suggested Equipment: 1) 5 digit ohm meter, capable of 4-wire measurements. (Accuracy ±0.005% of reading or better, with an excitation

More information

EV Software Rev Evaluation System User Guide. Introduction. Contents. Hardware and Software Setup. Software Installation

EV Software Rev Evaluation System User Guide. Introduction. Contents. Hardware and Software Setup. Software Installation Contents Evaluation System User Guide Software Rev 2.0.1 Introduction Section Page No. Introduction 1 Kit Contents 1 Hardware and Software Setup 1 Software Installation 1 Hardware Connection 1 Operation

More information

SERIES 3000 THERMOMETER OPERATING INSTRUCTIONS

SERIES 3000 THERMOMETER OPERATING INSTRUCTIONS SERIES 3000 THERMOMETER OPERATING INSTRUCTIONS 3000.doc 1 SERIES 3000 THERMOMETER OPERATING INSTRUCTIONS SOFTWARE VERSION 6.1 Supplied Accessories 1 Mains Cord 1 Operating Instructions (English) When unpacked,

More information

CFM/CMM Hot-Wire Thermoanemometer

CFM/CMM Hot-Wire Thermoanemometer User Manual CFM/CMM Hot-Wire Thermoanemometer with NIST-Traceable Calibration Model 20250-16 Max Min Flow Temp THE STANDARD IN PRECISION MEASUREMENT 2 Introduction The Digi-Sense CFM/CMM Hot-Wire Thermoanemometer

More information

CII: Current Input, Isolated

CII: Current Input, Isolated Safety 1. Application CII Driver Card 2. Installation 2.1 Services 2.2 Driver Card Installation 2.3 Driver Wiring 3. Configuration - Operation 3.1 Diagnostics 3.2 Calibration 4. Specifications Safety Electrical

More information

TEMPERATURE CALIBRATOR TC305

TEMPERATURE CALIBRATOR TC305 TEMPERATURE CALIBRATOR TC305 The TC305 Gold Line temperature calibrator is designed for calibration of modern temperature/ electric instruments both in laboratory/workshop and on-site. This extremely high

More information

CPD8500 EMM calibration sled

CPD8500 EMM calibration sled Utility Manual CPD8500 EMM calibration sled Transducer utility manual 0020646001 10/2018, Mensor, LP. All rights reserved. Mensor is a registered trademark of Mensor, LP. All other brand and product names

More information

MODBUS RTU I/O Expansion Modules - Models C267, C277, and C287. Installation and Operations Manual Section 50

MODBUS RTU I/O Expansion Modules - Models C267, C277, and C287. Installation and Operations Manual Section 50 MODBUS RTU I/O Expansion Modules - Models C267, C277, and C287 Installation and Operations Manual 00-02-0651 09-01-09 Section 50 In order to consistently bring you the highest quality, full featured products,

More information

HAKKO FG-101 Calibration Instructions Revision

HAKKO FG-101 Calibration Instructions Revision HAKKO FG-101 Calibration Instructions Revision 2013-10 Tools Required: Room Temperature Thermometer Yokogawa CA-71 Portable Calibrator or equivalent Yokogawa 2786 Decade Resistance Box or equivalent Fluke

More information

Multi-functional precision thermometer CTR3000

Multi-functional precision thermometer CTR3000 Calibration technology Multi-functional precision thermometer CTR3000 WIKA data sheet CT 60.15 Applications Pharmaceutical industry Industry (laboratory, workshop and production) Temperature sensor and

More information

CRAGG RAILCHARGER Instruction Manual for 10DTC-12V 20DTC-12V 30DTC-24V 40DTC-12V 60DTC-12V

CRAGG RAILCHARGER Instruction Manual for 10DTC-12V 20DTC-12V 30DTC-24V 40DTC-12V 60DTC-12V CRAGG RAILCHARGER for 10DTC-12V 20DTC-12V 30DTC-24V 40DTC-12V 60DTC-12V Contents 1 Warnings, Cautions, and Notes... 1 2 Description... 2 3 Features... 2 3.1 STANDARD FEATURES... 2 3.2 CHARGER REGULATION...

More information

TC41-Thermocouple Thermometers User Manual

TC41-Thermocouple Thermometers User Manual TC41-Thermocouple Thermometers User Manual Product Registration cs@perfect-prime.com Product Introduction This thermometer can be used to measure up to 4 different temperatures simultaneously, and with

More information

EV Evaluation System User Guide. Contents. Kit Contents. Introduction

EV Evaluation System User Guide. Contents. Kit Contents. Introduction Contents EV2200 40 Evaluation System User Guide Section Page No. Introduction 1 Kit Contents 1 Hardware and Software Setup 2 Software Installation 2 Hardware Connection 2 Operation 2 Starting the Program

More information

6-Channel Monitor. Installation and Operation Manual

6-Channel Monitor. Installation and Operation Manual 3211 Fruitland Ave Los Angeles, CA 90058 Catalyst Monitor 6-Channel Monitor Version 2 Installation and Operation Manual Rev. H P/N145F-12964 PCO - 00009743 (c) Copyright 2015, Barksdale, Inc. All Rights

More information

Ultra-Accurate Measurement for Temperature and Voltage

Ultra-Accurate Measurement for Temperature and Voltage Ultra-Accurate Measurement for Temperature and Voltage MEASURpoint is an ultra-accurate instrument for measuring any combination of thermocouple, RTD, and voltage inputs. MEASURpoint is available as a

More information

For technical support please contact

For technical support please contact DaqPRO Calibration Procedure This document outlines calibration procedure for fourtec Fourier Technologies DaqPRO 5300. Calibration is performed on each of the DaqPRO s inputs. Use the calibration sheet

More information

PIECAL 510B/511B RTD Simulator Operating Instructions

PIECAL 510B/511B RTD Simulator Operating Instructions PIECAL 510B/511B RTD Simulator Operating Instructions (Shown without optional boot) (Shown with optional boot) Product Description Easy to use With the PIECAL 510B/511B you can check & calibrate all your

More information

TouchKit TouchScreen Controller User Manual for Windows NT4 Version: 3.4.0

TouchKit TouchScreen Controller User Manual for Windows NT4 Version: 3.4.0 TouchKit TouchScreen Controller User Manual for Windows NT4 Version: 3.4.0 1 CONTENT CHAPTER 1. TOUCH PANEL CONTROLLER 2 1.1 Controller 2 1.2 Specifications and Features 3 CHAPTER 2. INSTALLING TOUCHKIT

More information

3700 SERIES USER MANUAL

3700 SERIES USER MANUAL SAFETY GUIDE This manual contains the precautions necessary to ensure your personal safety as well as for protection for the products and the connected equipment. These precautions are highlighted with

More information

9146-R Smart Connector Connectors for the TE 9146-R

9146-R Smart Connector Connectors for the TE 9146-R Instruments 9146-R Smart Connector Connectors for the TE 9146-R Enables plug-and-play type operation of the 9146-R with a variety of input types. All transducer s information is contained within the plug

More information

MODEL 3150 SUSPENDED SOLIDS ANALYZER MODEL 35/35L OPTICAL SUSPENDED SOLIDS SENSOR

MODEL 3150 SUSPENDED SOLIDS ANALYZER MODEL 35/35L OPTICAL SUSPENDED SOLIDS SENSOR MODEL 3150 SUSPENDED SOLIDS ANALYZER MODEL 35/35L OPTICAL SUSPENDED SOLIDS SENSOR REVISION 22 August 2016 Insite Instrumentation Group, Inc 80 Whisperwood Blvd. Suite 107 Slidell, LA 70458 Phone: (985)

More information

EnCell Battery Cell Monitor

EnCell Battery Cell Monitor EnCell Battery Cell Monitor Instruction Manual Model RCM15S12 NERC Compliant YO R U H T PA TO Z O R E W O D N M I T E enchargepowersystems.com sales@enchargepowersystems.com (888) 407.5040 Contents 1 Warnings,

More information

TouchKit TouchScreen Controller User Guide for Windows 2000 / XP Version: 3.2.4

TouchKit TouchScreen Controller User Guide for Windows 2000 / XP Version: 3.2.4 TouchKit TouchScreen Controller User Guide for Windows 2000 / XP Version: 3.2.4 TouchKit Guide for Win2000/XP v3.2.4 0 CONTENT CHAPTER 1. TOUCH PANEL CONTROLLER...2 1.1 CONTROLLER...2 1.2 SPECIFICATIONS

More information

Critical Fixes... 6 Enhancements... 7 Non-critical Fixes... 7 B05 Release... 8 Critical Fixes... 8 Enhancements... 9 Non-critical Fixes...

Critical Fixes... 6 Enhancements... 7 Non-critical Fixes... 7 B05 Release... 8 Critical Fixes... 8 Enhancements... 9 Non-critical Fixes... Keithley Instruments, Inc. 28775 Aurora Road Cleveland, Ohio 44139-1891 440-248-0400 Fax: 440-248-6168 http://www.keithley.com 2700 B09 Firmware Release Notes Contents Contents... 1 General Information...

More information

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm) 4-20 ma & Relay Output Features 4-20 ma, ± 10 V, TC & RTD Inputs 12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm) 24 VDC @ 200 ma Transmitter Power Supply Options Type

More information

5450 NW 33rd Ave, Suite 104 Fort Lauderdale, FL Fruitland Ave Los Angeles, CA UM Channel Monitor.

5450 NW 33rd Ave, Suite 104 Fort Lauderdale, FL Fruitland Ave Los Angeles, CA UM Channel Monitor. 5450 NW 33rd Ave, Suite 104 Fort Lauderdale, FL 33309 3211 Fruitland Ave Los Angeles, CA 90058 UM-600 6-Channel Monitor Version 2 Installation and Operation Manual Rev. G P/N145F-12990 PCO 00007462 (c)

More information

Ultra-Accurate Temperature Measurement Instruments

Ultra-Accurate Temperature Measurement Instruments TEMPpoint Temperature Measurement Instruments Ultra-Accurate Temperature Measurement Instruments TEMPpoint is a series of precision temperature measurement instruments designed for high accuracy and industrial

More information

TouchKit TouchScreen Controller User Guide for Windows NT4 Version: 3.2.1

TouchKit TouchScreen Controller User Guide for Windows NT4 Version: 3.2.1 TouchKit TouchScreen Controller User Guide for Windows NT4 Version: 3.2.1 TouchKit Guide for WinNT4 v3.2.1 0 CONTENT CHAPTER 1. TOUCH PANEL CONTROLLER... 2 1.1 CONTROLLER... 2 1.2 SPECIFICATIONS AND FEATURES...

More information

Advanced Test Equipment Rentals ATEC (2832)

Advanced Test Equipment Rentals ATEC (2832) Established 1981 Appendix B Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) Model 268 Communicator INTRODUCTION This appendix provides basic communicator information on the Rosemount

More information

Weeder Technologies. 90-A Beal Pkwy NW, Fort Walton Beach, FL

Weeder Technologies. 90-A Beal Pkwy NW, Fort Walton Beach, FL e e d e r Technologies 90-A Beal Pkwy NW, Fort Walton Beach, FL 32548 www.weedtech.com 850-863-5723 Thermocouple Input Module This product is Obsolete due to the main A/D chip which is no longer being

More information

AMETEK JOFRA CSC200. Temperature Calibrator. Reference Manual

AMETEK JOFRA CSC200. Temperature Calibrator. Reference Manual AMETEK JOFRA CSC200 Temperature Calibrator Reference Manual 1. Introduction The Ametek Jofra CSC200 is designed to calibrate a wide range of thermocouple and RTD devices. It can source or measure up to

More information