Optical laser distance sensors. Dimensioned drawing

Size: px
Start display at page:

Download "Optical laser distance sensors. Dimensioned drawing"

Transcription

1 Optical laser distance sensors Dimensioned drawing We reserve the right to make changes DS_ODSL96BMLTOFS12_en_ fm en / V DC m Measurement range up to 10000mm at 90% diffuse reflection Reflection-independent distance information up to 6000mm Highly insensitive to extraneous light IO-Link/OLED display and key pad for configuration Measurement value is indicated in mm on OLED display Measurement range and mode adjustable IEC IEC Accessories: (available separately) IP 69K IP 67 Mounting systems Cable with M12 connector (K-D ) IO-Link master set MD12-US2-IOL1 ( ) and K-DS M12A-M12A-4P-2m-PVC cable ( ) A Green indicator diode B Indicator diode yellow C Transmitter D Receiver E Optical axis F Device plug M12x1 G Countersinking for SK nut M5, 4.2mm deep H OLED display and membrane keyboard I Reference edge for the measurement (cover glass) Electrical connection ODSL 96B M/L-S12

2 Specifications Optical data Measurement range mm (90% diffuse reflection), mm (6 90% diffuse reflection) Resolution 3mm Light source laser Wavelength 658nm (visible red light) Light spot approx. 7x7mm² at 10m Max. output power 248mW Pulse duration 6.5ns Error limits (relative to measurement range end value 6000mm) Absolute measurement accuracy 1) ±0.5% Repeatability 2) ±5mm B/W detection thresh. (6 90% rem.) ± 10mm Temperature drift ± 1.5mm/K Timing Measurement time 3) "Fast" operating mode: 1.4ms "Standard" operating mode: 10ms "Precision" operating mode: 50ms (factory setting) Delay before start-up 300ms Electrical data Operating voltage U B 18 30V (incl. residual ripple) Residual ripple 15% of U B Open-circuit current 150mA Sensor operating mode IO-Link COM2 (38.4kBaud), Frame 2.2, Vers. 1.0, min. cycle time 2.2ms SIO not supported Indicators Green LED continuous light ready off no voltage Yellow LED continuous light object within measurement range off no object within measurement range Mechanical data Metal housing Housing diecast zinc Optics cover glass Weight 380g Connection type M12 connector Environmental data Ambient temp. (operation/storage) -20 C +50 C / -30 C +70 C Protective circuit 4) 1, 2, 3 VDE safety class 5) II, all-insulated Protection class IP 67, IP 69K 6) Laser class 2 (acc. to EN ) Standards applied IEC ) For mm measurement range, luminosity coefficient 6% 90%, "Precision" operating mode, floating average calculation taking 30 measurement values into account, at 20 C after 20 min. warmup time, medium range of U B, measurement object 50x50mm² 2) Same object, identical environmental conditions, "Precision" operating mode, floating average calculation taking 30 measurement values into account, after 20 min. warmup time, measurement object 50x50mm² 3) Internal measurement time distance sensor 4) 1=transient protection, 2=polarity reversal protection, 3=short circuit protection for all outputs 5) Rating voltage 250VAC, with cover closed 6) IP 69K test in accordance with DIN part 9 simulated, high pressure cleaning conditions without the use of additives. Acids and bases are not part of the test Tables Diagrams Remarks Approved purpose: This product may only be used by qualified personnel and must only be used for the approved purpose. This sensor is not a safety sensor and is not to be used for the protection of persons. Order guide Designation Part no. IO-Link interface ODSL 96B M/L-S

3 Optical laser distance sensors IO-Link process data Output data device Data bit A15 A14 A13 A12 A11 A10 A9 A8 A7 A6 A5 A4 A3 A2 A1 A0 MSB 16 bit measurement value LSB 16 bit measurement value: distance 1 bit output resolution: 1mm Signal too weak: Signal error: 65534

4 IO-Link service data Sensors with IO-Link interface can be configured and diagnosed via the service data. Parameters Measure mode A measurement mode for adapting to the application task can be activated with this parameter. There is a selection of three measurement modes (standard, precision, speed). By selecting the mode, the following results are achieved: Standard: Precision: Speed: standard setting factory setting, twice as accurate as the standard setting, approx. 5 times slower three times less accuracy than the standard setting, approx. 8 times faster The following table provides an overview of the effects of the individual parameters on the measurement function. Accuracy Measurement time Measurement value update Ambient light Standard + 10ms + ++ Precision ++ 50ms Speed - 1.4ms Measurement filter A measurement filter for adapting to the application task can be activated with this parameter. There is a selection of three options (off, averaging, center value). By selecting the filter, the following results are achieved: Off: no filtering of the measurement values. Averaging: a moving average from the last 2 99 measurement values (setting of the number with measurem. count) is calculated and output. If the measurement value changes abruptly, the output value moves linearly over n measurements from the old to the new measurement value. The time until the measurement value is updated is therefore not affected by the number of measurements; the response time for distance changes slows down. Center value: filtering out of extreme values - the average is calculated from individual measurements. The number of individual measurements used for this purpose is selected via measurem. count (10, 20, 30, 40 or 50). The setting under filter depth specifies whether only the most extreme (coarse), the middle (medium) or the lowest deviations (fine) should be filtered out. The following table provides an overview of the effects of the individual parameters on the measurement function. Updating measurement time Response time for small change in distance Response time for large change in distance Filtering of individual faulty measurements Filtering of cumulative faulty measurements Off Averaging o - Center value Number of measurement values (averaging) This parameter defines the number of individual measurements which are used for filtering. Number of measurement values (center value) This parameter defines the number of individual measurements which are used for filtering. Filter depth (center value) This parameter defines the filter gauge (medium, coarse, fine). Display This parameter determines the display setting on the sensor (on, off, auto). Button lock This parameter determines whether the key pad on the sensor is locked or activated.

5 Optical laser distance sensors System commands: Laser transmitter activation This system command switches on the laser transmitter. Laser transmitter deactivation This system command switches off the laser transmitter. If the sensor is deactivated, the last measurement value detected is frozen. The state of the laser can be seen from the sensor status. Setting to factory setting This system command restores the factory settings of the sensor. Diagnostics (observation) Signal too weak [process value 65535] or signal failure [process value 65534] Reception signal is not sufficient: either no object is in the measurement range or the signal from the object is too weak for detection. A permanently displayed signal failure indicates that the sensor has a defect. Signal warning Low reception signal: the object is not detected reliably, e.g. because the signal from the object is very weak. Laser activation Status information on whether the laser transmitter is activated or deactivated. Measurement range sensor Status information on whether an object is located in the measurement range of the sensor. If parameters are changed on the device via the display and keyboard, the master is not signaled. In the event the master sends an explicit request, however, the changed value is available. Detailed information about the IO-Link service data and the IODD can be found at Leuze website.

6 Working safely Attention Laser Radiation! The optical distance sensors ODSL 96B operate with a red light laser of class 2 acc. to EN If you look into the beam path over a longer time period, the retina of your eye may be damaged! Never look directly into the beam path! Do not point the laser beam of the ODSL 96B at persons! ODSL 96B When mounting and aligning the ODSL 96B take care to avoid reflections of the laser beam off reflective surfaces! The use of operating and adjusting devices other than those specified in the technical description, carrying out of differing procedures, or improper use of the optical laser distance sensor may lead to dangerous exposure to radiation! The use of optical instruments or devices in combination with the device increases the danger of eye damage! Adhere to the applicable legal and local regulations regarding protection from laser beams acc. to EN in its latest version. The ODSL 96B uses a laser diode with low power in the visible red light range with an emitted wavelength of about 658nm. The glass lens cover is the only opening through which the laser radiation can escape from the device. The housing of the ODSL 96B is sealed and has no parts that need to be adjusted or maintained by the user. The device must not be tampered with and must not be changed in any way! Unauthorized opening of the device voids the warranty! It is important to attach the stick-on labels delivered with the device (notice signs)! If the signs could be covered due to the installation location of the ODSL 96B, attach them close to the ODSL 96B so that it is not possible to look into the laser beam when reading the notices!

7 Optical laser distance sensors Dimensioned drawing We reserve the right to make changes DS_ODSL96BMTOFS12_en_ fm en / V DC m Measurement range up to 10000mm at 90% diffuse reflection Reflection-independent distance information up to 6000mm Highly insensitive to extraneous light Analog current or voltage output PC/OLED display and membrane keyboard for configuration Measurement value is indicated in mm on OLED display Measurement range and mode adjustable IEC IEC Accessories: (available separately) Mounting systems Cable with M12 connector (K-D ) Configuration software IP 69K IP 67 A Green indicator diode B Indicator diode yellow C Transmitter D Receiver E Optical axis F Device plug M12x1 G Countersinking for SK nut M5, 4.2mm deep H OLED display and membrane keyboard I Reference edge for the measurement (cover glass) Electrical connection ODSL 96B M/C6 ODSL 96B M/V6 ODSL 96B M/C66 ODSL 96B M/D26 ODSL 96B M/D36

8 Specifications Optical data Measurement range mm (90% diffuse reflection), mm (6 90% diffuse reflection) Resolution 3mm Light source laser Wavelength 658nm (visible red light) Light spot approx. 7x7mm² at 10m Laser warning notice see Remarks Error limits (relative to measurement range end value 6000mm) Absolute measurement accuracy 1) ±0.5% Repeatability 2) ±5mm B/W detection thresh. (6 90% rem.) ± 10mm Temperature drift ± 1.5mm/K Timing Measurement time "Fast" operating mode: 1.4ms "Standard" operating mode: 10ms "Precision" operating mode: 50ms (factory setting) Delay before start-up 300ms Electrical data Operating voltage U B C6/C66/V VDC (incl. residual ripple) D26/D VDC (incl. residual ripple) Residual ripple 15% of U B Open-circuit current 150mA Switching output push-pull switching output 3), PNP light switching, NPN dark switching Signal voltage high/low (U B -2 V)/ 2V Analog output V6 voltage 1 10V / 0 10V / 1 5V / 0 5V, R L 2k C6/C66 current 4 20mA, R L 500 Serial interface D26/D36 RS 232/RS 485, Bd, 1 start bit, 8 data bits, 1 stop bit, no parity Transmission protocol 14 bit, 16 bit, ASCII, Remote Control Indicators Teach-in on GND Green LED continuous light ready off no voltage Yellow LED continuous light object within range / switching output off object out of range / switching output Mechanical data Metal housing Housing diecast zinc Optics cover glass Weight 380g Connection type M12 connector Environmental data Ambient temp. (operation/storage) -20 C +50 C / -30 C +70 C Protective circuit 4) 1, 2, 3 VDE safety class 5) II, all-insulated Protection class IP 67, IP 69K 6) Laser class 2 (acc. to EN ) Standards applied IEC ) For mm measurement range, luminosity coefficient 6% 90%, "Precision" operating mode, floating average calculation taking 30 measurement values into account, at 20 C after 20 min. warmup time, medium range of U B, measurement object 50x50mm² 2) Same object, identical environmental conditions, "Precision" operating mode, floating average calculation taking 30 measurement values into account, after 20 min. warmup time, measurement object 50x50mm² 3) The push-pull switching outputs must not be connected in parallel 4) 1=transient protection, 2=polarity reversal protection, 3=short circuit protection for all outputs 5) Rating voltage 250VAC, with cover closed 6) IP 69K test in accordance with DIN part 9 simulated, high pressure cleaning conditions without the use of additives. Acids and bases are not part of the test Order guide Designation Part no. Analogue current output Current output, teach input, 1 push/pull output ODSL 96B M/C6-S Current output, 2 push/pull outputs ODSL 96B M/C66-S Analogue voltage output Voltage output, teach input, 1 push/pull output ODSL 96B M/V6-S Serial digital output RS 232, 1 push/pull output ODSL 96B M/D26-S RS 485, 1 push/pull output ODSL 96B M/D36-S Tables Diagrams Remarks Approved purpose: The ODSL 96B laser distance sensors are optoelectronic sensors for the optical, contactless measurement of the distance to objects. This product may only be used by qualified personnel and must only be used for the approved purpose. This sensor is not a safety sensor and is not to be used for the protection of persons. 248 mw 6,5 ns 658 nm

9 Optical laser distance sensors Analog output: characteristic curve for factory setting Factory setting A B C D E F Area not defined Linearity not defined Measurement range Object present No object detected Measurement distance ca Serial output: transmission protocol for factory setting 9600Bd, 1 start bit, 8 data bits, 1 stop bit, transmission protocol ASCII measurement values Transmission format: MMMMM<CR> MMMMM = 5-digit measurement value in mm (resolution 1mm) <CR> = ASCII character "Carriage Return" (x0d) Measurement mode and measurement filter The user can individually adapt the measurement system of the ODSL 96B to various applications. By configuring the measurement mode and measurement filter, either a higher measurement accuracy or, alternatively, faster measurements can be achieved. Configuration can be performed either directly on the sensor or with the ODS 96B configuration software. Optimization of measurement mode In the Application menu, you can set 3 different measurement filters. Menu setting Application -> Measure Mode -> Precision Application -> Measure Mode -> Standard Application -> Measure Mode -> Speed Effect high accuracy, measurement time of individual measurement: 50ms exact and fast, measurement time of individual measurement: 10ms fast measurement, measurement time of individual measurement: 1.4ms Optimization of measurement filter To achieve more precise measurement values, a measurement filter can be adjusted in addition to the measurement mode. In most cases, the use of a floating average results in a reduction in the variance of the measurement values. To use this, select the menu setting Application -> Measure Filter -> Averaging. The number of measurement values to be taken into account can be set to a value between 1 99 via menu setting Application -> Measure Filter -> Averaging -> Measurem. Count. The measurement value display on the OLED display can be used to assess the efficiency of the selected measurement mode and measurement filter in the application. The update rate of the OLED display is always 2Hz. The ODS 96B configuration software provides identical functionality. Factory setting of measurement mode: On delivery, the sensor is preset so that measurement values with the maximum possible accuracy are achieved: Measurement mode Precision. Reset to factory settings Press the factory. button while switching on the device to reset the configuration of the ODSL 96B to the state upon delivery from the Press the button again to reset all parameters to the factory settings. All settings made previously are permanently lost. Press and the ODSL 96B returns to measurement operation without resetting the parameters. You can also use the menu or the configuration software to reset to factory settings. For this purpose, select menu item Settings -> FactorySettings -> Execute. The ODS 96B configuration software can also be used to reset the ODSL 96B to factory settings. FactorySettings Execute

10 Teach-in of switching outputs, analog characteristic output curve and Preset If you have changed the factory setting for teaching under Input Mode, activate on the OLED display the menu item Input -> Input Mode -> Teach. To teach, proceed as follows: 1.Position measurement object at the desired measurement distance. 2.The respective teach function is activated on the teach input for the duration of a level change T (see graphical representation). The level conditions describe the levels with menu setting Input -> Input Mode -> Input polarity -> Active High +24V (factory setting). Active High +24V T ODSL 96B Inactive Low 0V t Teach function Switching output Q1 Distance value for start of measurement range = 1V or 4mA at analog output Distance value for end of measurement range = 10V or 20mA at analog output If the inactive level is continuously applied on the teach input, the teach input is locked. For menu setting Input -> Input Mode -> Input polarity -> Active Low +0V, inverted input signals are used during teaching. Preset Teach-In Duration T 20 80ms ms ms On the OLED display, activate for this purpose menu item Input -> Input Mode -> Preset. The preset teach occurs in a manner analogous to that for the teach-in for switching output Q1. Working safely Attention Laser Radiation! The optical distance sensors ODSL 96B operate with a red light laser of class 2 acc. to EN If you look into the beam path over a longer time period, the retina of your eye may be damaged! Never look directly into the beam path! Do not point the laser beam of the ODSL 96B at persons! When mounting and aligning the ODSL 96B take care to avoid reflections of the laser beam off reflective surfaces! The use of operating and adjusting devices other than those specified in the technical description, carrying out of differing procedures, or improper use of the optical laser distance sensor may lead to dangerous exposure to radiation! The use of optical instruments or devices in combination with the device increases the danger of eye damage! Adhere to the applicable legal and local regulations regarding protection from laser beams acc. to EN in its latest version. The ODSL 96B uses a laser diode with low power in the visible red light range with an emitted wavelength of about 658nm. The glass optics cover is the only opening through which the laser radiation can escape from the device. The housing of the ODSL 96B is sealed and has no parts that need to be adjusted or maintained by the user. The device must not be tampered with and must not be changed in any way! The destruction of the seal voids the warranty! It is important that you attach the sticky labels supplied to the device (notice signs and laser emission symbol)! If the signs would be covered due to the installation situation of the ODSL 96B, attach them close to the ODSL 96B such that reading the notices cannot lead to looking into the laser beam!

11 ODSIL 96B Optical laser distance sensors Dimensioned drawing We reserve the right to make changes DS_ODSIL96BMTOF_en_ fm en / V DC m Measurement range up to 10000mm at 90% diffuse reflection Reflection-independent distance information up to 6000mm Infrared laser diode with laser class 1 Switchable alignment aid with red light laser diode with laser class 1 Highly insensitive to extraneous light Analog current or voltage output PC/OLED display and membrane keyboard for configuration Measurement value is indicated in mm on OLED display Measurement range and mode adjustable Input (pin 2) for deactivation of laser, triggering, offset correction or teach-in IEC IEC Accessories: (available separately) Mounting systems Cable with M12 connector (K-D ) Configuration software IP 69K IP 67 A Green indicator diode B Indicator diode yellow C Transmitter (infrared light) for distance measurement D Receiver E Optical axis F Device plug M12x1 G Countersinking for SK nut M5, 4.2mm deep H OLED display I Reference edge for the measurement (cover glass) K Key pad L Green and yellow indicator diodes M Transmitter (red light) as alignment aid N Button for switching red alignment laser on/off Electrical connection ODSIL 96B M/C6 ODSIL 96B M/V6

12 ODSIL 96B Specifications Optical data Measurement range mm (90% diffuse reflection), mm (6 90% diffuse reflection) Resolution 3mm Light source laser Wavelength measurement laser: 785nm (infrared light), alignment laser: 658nm (visible red light) Light spot approx. 7x7mm² at 10m Max. output power measurement laser: 268mW, alignment laser: 190mW Pulse duration measurement laser: 6.5ns, alignment laser: 6.5ns Error limits (relative to measurement range end value 6000mm) Absolute measurement accuracy 1) ±0.5% Repeatability 2) ±5mm B/W detection thresh. (6 90% rem.) ± 10mm Temperature drift ± 1.5mm/K Timing Measurement time "Fast" operating mode: 2.8ms "Standard" operating mode: 20ms "Precision" operating mode: 100ms (factory setting) Delay before start-up 300ms Electrical data Operating voltage U B C6/V VDC (incl. residual ripple) Residual ripple 15% of U B Open-circuit current 150mA Switching output push-pull switching output 3), PNP light switching, NPN dark switching Signal voltage high/low (U B -2 V)/ 2V Analog output V6 voltage 1 10V / 0 10V / 1 5V / 0 5V, R L 2k C6 current 4 20mA, R L 500 Indicators Teach-in on GND Green LED continuous light ready off no voltage Yellow LED continuous light object within range / switching output off object out of range / switching output Mechanical data Metal housing Housing diecast zinc Optics cover glass Weight 380g Connection type M12 connector Environmental data Ambient temp. (operation/storage) -20 C +50 C / -30 C +70 C Protective circuit 4) 1, 2, 3 VDE safety class 5) II, all-insulated Protection class IP 67, IP 69K 6) Laser class 1 (acc. to EN ) Standards applied IEC ) For mm measurement range, luminosity coefficient 6% 90%, "Precision" operating mode, floating average calculation taking 30 measurement values into account, at 20 C after 20 min. warmup time, medium range of U B, measurement object 50x50mm² 2) Same object, identical environmental conditions, "Precision" operating mode, floating average calculation taking 30 measurement values into account, after 20 min. warmup time, measurement object 50x50mm² 3) The push-pull switching outputs must not be connected in parallel 4) 1=transient protection, 2=polarity reversal protection, 3=short circuit protection for all outputs 5) Rating voltage 250VAC, with cover closed 6) IP 69K test in accordance with DIN part 9 simulated, high pressure cleaning conditions without the use of additives. Acids and bases are not part of the test Order guide Designation Part no. Analogue current output Current output, teach input, 1 push/pull output ODSIL 96B M/C6-S Analogue voltage output Voltage output, teach input, 1 push/pull output ODSIL 96B M/V6-S Tables Diagrams Remarks Approved purpose: This product may only be used by qualified personnel and must only be used for the approved purpose. This sensor is not a safety sensor and is not to be used for the protection of persons. The red light laser diode is used exclusively as an alignment aid. The beam radiates at a distance of 17mm parallel to the infrared measurement beam (see dimensioned drawing).

13 ODSIL 96B Optical laser distance sensors Analog output: characteristic curve for factory setting Factory setting A B C D E F Area not defined Linearity not defined Measurement range Object present No object detected Measurement distance Measurement mode and measurement filter The user can individually adapt the measurement system of the ODSIL 96B to various applications. By configuring the measurement mode and measurement filter, either a higher measurement accuracy or, alternatively, faster measurements can be achieved. Configuration can be performed either directly on the sensor or with the ODS 96B configuration software. Optimization of measurement mode In the Application menu, you can set 3 different measurement filters. Menu setting Application -> Measure Mode -> Precision Application -> Measure Mode -> Standard Application -> Measure Mode -> Speed Effect high accuracy, measurement time of individual measurement: 100ms exact and fast, measurement time of individual measurement: 20ms fast measurement, measurement time of individual measurement: 2.8ms Optimization of measurement filter To achieve more precise measurement values, a measurement filter can be adjusted in addition to the measurement mode. In most cases, the use of a floating average results in a reduction in the variance of the measurement values. To use this, select the menu setting Application -> Measure Filter -> Averaging. The number of measurement values to be taken into account can be set to a value between 1 99 via menu setting Application -> Measure Filter -> Averaging -> Measurem. Count. The measurement value display on the OLED display can be used to assess the efficiency of the selected measurement mode and measurement filter in the application. The update rate of the OLED display is always 2Hz. The ODS 96B configuration software provides identical functionality. Factory setting of measurement mode: On delivery, the sensor is preset so that measurement values with the maximum possible accuracy are achieved: Measurement mode Precision. Reset to factory settings Press the factory. button while switching on the device to reset the configuration of the ODSIL 96B to the state upon delivery from the Press the button again to reset all parameters to the factory settings. All settings made previously are permanently lost. Press and the ODSIL 96B returns to measurement operation without resetting the parameters. You can also use the menu or the configuration software to reset to factory settings. For this purpose, select menu item Settings -> FactorySettings -> Execute. The ODS 96B configuration software can also be used to reset the ODSIL 96B to factory settings. FactorySettings Execute

14 Teach-in of switching outputs, analog characteristic output curve and Preset If you have changed the factory setting for teaching under Input Mode, activate on the OLED display the menu item Input -> Input Mode -> Teach. To teach, proceed as follows: 1.Position measurement object at the desired measurement distance. 2.The respective teach function is activated on the teach input for the duration of a level change T (see graphical representation). The level conditions describe the levels with menu setting Input -> Input Mode -> Input polarity -> Active High +24V (factory setting). Active High +24V T ODSIL 96B Inactive Low 0V t Teach function Switching output Q1 Distance value for start of measurement range = 1V or 4mA at analog output Distance value for end of measurement range = 10V or 20mA at analog output If the inactive level is continuously applied on the teach input, the teach input is locked. For menu setting Input -> Input Mode -> Input polarity -> Active Low +0V, inverted input signals are used during teaching. Preset Teach-In Duration T 20 80ms ms ms On the OLED display, activate for this purpose menu item Input -> Input Mode -> Preset. The preset teach occurs in a manner analogous to that for the teach-in for switching output Q1.

Optical distance sensors. Dimensioned drawing

Optical distance sensors. Dimensioned drawing Optical distance sensors Dimensioned drawing en 03-2012/11 50110829 120 1400mm 18-30 V DC We reserve the right to make changes DS_ODS96BMV61400S12_en_50110829.fm Reflection-independent distance information

More information

Optical distance sensors. Dimensioned drawing

Optical distance sensors. Dimensioned drawing Optical distance sensors Dimensioned drawing We reserve the right to make changes DS_ODS10L1_25M8L_en_50129321.fm en 04-2016/08 50129321 100 25000mm Measurement range up to 25000mm on HighGain foil Analog

More information

Retro-reflective photoelectric sensors. Dimensioned drawing. Receiver Transmitter Optical axis LED yellow 90 turning connector. Electrical connection

Retro-reflective photoelectric sensors. Dimensioned drawing. Receiver Transmitter Optical axis LED yellow 90 turning connector. Electrical connection IPRK 8 Retro-reflective photoelectric sensors Dimensioned drawing 0.05 8m A 2 LS A²LS - active suppression of extraneous light Integrated AS-i slave M12 turning connector or cable connection Visible red

More information

ADVANCED ultrasonic sensors with 2 switching outputs. Dimensioned drawing

ADVANCED ultrasonic sensors with 2 switching outputs. Dimensioned drawing Dimensioned drawing en 2-214/2 5124879 25 4mm 15 13mm 15-3 V DC We reserve the right to make changes DS_HTU418BX3LT4_en_5124879.fm Largely surface-independent function, ideal for the detection of liquids,

More information

Retro-reflective photoelectric sensors with polarisation filter. Dimensioned drawing. Electrical connection

Retro-reflective photoelectric sensors with polarisation filter. Dimensioned drawing. Electrical connection Retro-reflective photoelectric sensors with polarisation filter Dimensioned drawing 0 1.85m 10-30 V DC We reserve the right to make changes 96_b06e.fm Retro-reflective photoelectric sensor for safe detection

More information

DIFFUSE REFLECTION SCANNERS

DIFFUSE REFLECTION SCANNERS DIFFUSE REFLECTION SCANNERS Part description Part No.: Scanning range [mm] Typ. scan range limit [mm] Switching frequency Light source Output Switching Energetic diffuse reflection scanners RT 618 / 4-200

More information

Energetic diffuse reflection light scanner. Dimensioned drawing

Energetic diffuse reflection light scanner. Dimensioned drawing Energetic diffuse reflection light scanner Dimensioned drawing We reserve the right to make changes 93_c3gb.fm Part No. 51 1168 1-3 V DC 5 17mm 1mm Infrared light Background suppression through appropriate

More information

Laser retro-reflective photoel. sensors with polariz. filter for bottles. Dimensioned drawing

Laser retro-reflective photoel. sensors with polariz. filter for bottles. Dimensioned drawing Technical data and description PRK3CL Laser retro-reflective photoel. sensors with polariz. filter for bottles Dimensioned drawing en 01-2016/07 50132447 3 khz 0 500mm 10-30 V DC We reserve the right to

More information

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing Laser diffuse reflection light scanner with background suppression Dimensioned drawing We reserve the right to make changes DS_HRTL46B661_en_50113429_01.fm en 02-2014/06 50113429-01 10-30 V DC A 2 LS 50

More information

Leuze electronic. 96 Series. Product description

Leuze electronic. 96 Series. Product description 96 Series Product description Contents: 96 Series - Overview and advantages Special features of Series 96 Sensor selection table Data sheets All rights reserved, especially the rights of copying and translation.

More information

Trigger high-speed, retro-reflective sensors for bottles. Dimensioned drawing

Trigger high-speed, retro-reflective sensors for bottles. Dimensioned drawing Trigger high-speed, retro-reflective sensors for bottles Dimensioned drawing en 01-2013/11 50121192 10-30 V DC 0 3.6m 5 khz We reserve the right to make changes DS_PRK18BFX_en_50121192.fm Trigger high-speed,

More information

Retro-reflective photoelectric sensors with polarization filter. Dimensioned drawing

Retro-reflective photoelectric sensors with polarization filter. Dimensioned drawing Dimensioned drawing en 01-2016/07 50130059 1,5 khz 0 3.5m 10-30 V DC We reserve the right to make changes DS_PRK3CT_Flaschen_en_50130059.fm Polarized retro-reflective photoelectric sensor with autocollimation

More information

Optical Distance Sensors ODSL 8 / ODSL 30 / ODS 96

Optical Distance Sensors ODSL 8 / ODSL 30 / ODS 96 Leuze electronic Optical Distance Sensors ODSL 8 / ODSL 30 / ODS 96 Technical description / Software description All rights reserved, especially the rights of production, distribution and translation.

More information

Electrical connection

Electrical connection Energetic reflection light scanner Dimensioned drawing We reserve the right to make changes DS_ET5_en_50121955.fm en 04-2016/10 50121955 10-30 V DC A 2 LS 500 Hz 1 1000mm Energetic reflection light scanner

More information

Diffuse reflection light scanner with background suppression. Dimensioned drawing

Diffuse reflection light scanner with background suppression. Dimensioned drawing Specifications and description HRTR 55 Ex Diffuse reflection light scanner with background suppression Dimensioned drawing en 01-2011/05 50113748 1 khz 5 400mm 200mm with black-white error < 10% 10-30

More information

ADVANCED ultrasonic sensors with 2 switching outputs. Dimensioned drawing

ADVANCED ultrasonic sensors with 2 switching outputs. Dimensioned drawing ADVANCED ultrasonic sensors with 2 switching outputs Dimensioned drawing en 4-214/12 5124879 25 4mm 15 13mm 15-3 V DC We reserve the right to make changes DS_HTU418BX3LT4_en_5124879.fm Function largely

More information

Measurement range, typical

Measurement range, typical Light section sensor for object measurement Dimensioned drawing en 05-2011/05 50111079-02 200 800mm +Z +X -X 18-30 V DC We reserve the right to make changes DS_LPS_36en.fm Light section sensor for object

More information

Measurement range, typical

Measurement range, typical LPS 36 HI Light section sensor for object measurement Dimensioned drawing 200 600mm +Z +X -X We reserve the right to make changes DS_LPS36HI_en_50118357-02.fm en 03-2013/02 50118357-02 Light section sensor

More information

Throughbeam photoelectric sensors. Dimensioned drawing. Electrical connection

Throughbeam photoelectric sensors. Dimensioned drawing. Electrical connection Specifications and description Leuze electronic LS 97 Throughbeam photoelectric sensors Dimensioned drawing 9m 1-3 V DC! Throughbeam photoelectric sensor with infrared light or visible red light! Small

More information

3B Series PRODUCT DESCRIPTION

3B Series PRODUCT DESCRIPTION 3B Series PRODUCT DESCRIPTION Contents: 3B Series - overview and advantages Special features of Series 3B Sensor selection table Data sheets All rights reserved, especially the rights of copying and translation.

More information

Diffuse reflection light scanner with background suppression. Dimensioned drawing

Diffuse reflection light scanner with background suppression. Dimensioned drawing Specifications and description HRTR 3B Standard Dimensioned drawing We reserve the right to make changes DS_HRTR3B_Standard_en_51734.fm en 13-213/3 51734 1-3 V DC 1 khz A 2 LS 5 4mm 2mm with black-white

More information

Basic Series 18 mm Diameter Cylindrical Sensors

Basic Series 18 mm Diameter Cylindrical Sensors Diffuse Mode See pages 384-385 Features: Light on/dark on mode determined by wiring Adjustable sensitivity Sensing Ranges: 2 mm, 5 mm Outputs: NPN, PNP Thru-Beam Mode See pages 387-388 Features: Laser

More information

OPT2011. High-performance distance sensor. Operating Instructions

OPT2011. High-performance distance sensor. Operating Instructions OPT2011 High-performance distance sensor Operating Instructions Status: 15/07/2013 2 Table of Contents 1. Use for Intended Purpose 4 2. Safety Precautions 4 2.1. Safety Precautions 4 2.2. Laser/LED warning

More information

Dimensions. Model Number. Electrical connection emitter. Features. Electrical connection receiver. Product information. Pinout OBE12M-R100-S2EP-IO-V31

Dimensions. Model Number. Electrical connection emitter. Features. Electrical connection receiver. Product information. Pinout OBE12M-R100-S2EP-IO-V31 OBEM-R00-SEP-IO-V Dimensions. 8.7. 7..9. M (x).. ø... 0 9.9 7. 7. Release date: 08-06-08 :0 Date of issue: 08-06-08 80998_eng.xml Model Number OBEM-R00-SEP-IO-V Thru-beam sensor with -pin, M8 x connector

More information

Operating instructions Optical distance sensor. OID20x / / 2015

Operating instructions Optical distance sensor. OID20x / / 2015 Operating instructions Optical distance sensor OID20x 80228367 / 00 03 / 2015 Contents 1 Preliminary note...3 1.1 Symbols used...3 2 Safety instructions...3 3 Functions and features...4 3.1 Applications...4

More information

RS485 (S85- -Y13) Display (S85- -Y13) Setting push-buttons (S85- -Y03) Power supply Vdc 24 V +/- 20% PNP NPN Output Push pull

RS485 (S85- -Y13) Display (S85- -Y13) Setting push-buttons (S85- -Y03) Power supply Vdc 24 V +/- 20% PNP NPN Output Push pull LASER distance sensor for precise measurement up to 20 m with a millimeter of resolution and repeatability through the Time of Flight technique Time of Flight technology Class 2 visible red LASER for an

More information

Leuze electronic. 25 Series. Product description

Leuze electronic. 25 Series. Product description 25 Series Product description Contents: 25 Series - overview and advantages Special features of Series 25 Sensor selection table Data sheets All rights reserved, especially the rights of copying and translation.

More information

Dimensions. Model Number. Electrical connection. Features. Indicators/operating means. Product information OQT150-R100-2EP-IO-IR

Dimensions. Model Number. Electrical connection. Features. Indicators/operating means. Product information OQT150-R100-2EP-IO-IR Dimensions 1.5 8.7 5.5 11 1.5 M (x). 7.1 5. 1. 10 15.9 7. 19.95 Receiver Emitter. ø. 000 +50 100 Model Number Triangulation sensor (SbR) with fixed cable Features Miniature design with versatile mounting

More information

Dimensioned drawing. Measurement principle

Dimensioned drawing. Measurement principle rotoscan ROD4 plus Optical Distance Sensors Dimensioned drawing en 04-2010/05 50108253 0 65m 24 V D We reserve the right to make changes DS_ROD4plus_en.fm Measurement data transmission via Fast Ethernet

More information

Operating instructions Memory plug E /02 11/2011

Operating instructions Memory plug E /02 11/2011 Operating instructions Memory plug E30398 UK 704930/02 11/2011 Contents 1 Preliminary note...3 1.1 Symbols used...3 1.2 Terms used...3 2 Safety instructions...4 3 Factory setting...4 4 Functions and features...5

More information

OFP401P0189. Color Sensor. Operating Instructions

OFP401P0189. Color Sensor. Operating Instructions OFP401P0189 Color Sensor Operating Instructions Last update: 23 May 2013 2 Table of contents 1. Proper Use 4 2. Safety Precautions 4 3. EC Declaration of Conformity 4 4. Technical Data 5 4.1. Connection

More information

ODS 9 / OD 96B Optical Distance Sensors

ODS 9 / OD 96B Optical Distance Sensors ODS 9 / OD 96B Optical Distance Sensors en 04-2013/11 50107320-03 We reserve the right to make technical changes Table of contents 1 General information... 6 1.1 Explanation of symbols... 6 1.2 Important

More information

Dimensions. Model Number. Electrical connection. Features. Pinout. Product information. Indicators/operating means OMT300-R201-IEP-IO-V1

Dimensions. Model Number. Electrical connection. Features. Pinout. Product information. Indicators/operating means OMT300-R201-IEP-IO-V1 Dimensions. 9.9 6 Model Number 6.7 Ref. 6. 5. 5.8 7 7.7.6 ø. 9 50 78.5 Receiver Emitter M x..7 sensor with -pin, M x connector Electrical connection Features Medium design with versatile mounting options

More information

Dimensions. Model Number. Indicators/operating means. Features. Electrical connection. Product information OQT150-R100-2EP-IO-V31-L

Dimensions. Model Number. Indicators/operating means. Features. Electrical connection. Product information OQT150-R100-2EP-IO-V31-L Dimensions 21.5 8.7 5.5 11 1.5.2 M (2x).2.5 7.1 25. 1.2 10 15.9 7. 19.95 Reveiver Emitter ø.2 Model Number Triangulation sensor (SbR) with -pin, M8 x 1 connector Features Miniature design with versatile

More information

OPT2015. High-performance distance sensor. Operating Instructions

OPT2015. High-performance distance sensor. Operating Instructions OPT2015 High-performance distance sensor Operating Instructions 23.07.2013 2 Index 1. Proper Use 4 2. Safety Precautions 4 2.1. Safety Precautions 4 2.2. Laser/LED warning 4 3. EC Declaration of Conformity

More information

L-LAS Series L-LAS-LT-55. Design. L-LAS Series Laser Line Sensors. Product name: L-LAS-LT-55 (incl. Windows - software L-LAS-LT-Scope)

L-LAS Series L-LAS-LT-55. Design. L-LAS Series Laser Line Sensors. Product name: L-LAS-LT-55 (incl. Windows - software L-LAS-LT-Scope) L-LAS Series - Visible laser spot (red), class 2 laser product - Reference distance 55 mm - Measuring range typ. 10 mm, resolution typ. 0,01 mm - Integrated interference filter / red light filter - CCD

More information

0,25 mm false pulse suppression 4 program options 4 program options on/off switchable 4 preset levels or level set by customer.

0,25 mm false pulse suppression 4 program options 4 program options on/off switchable 4 preset levels or level set by customer. Copy counters SCATEC Overview product family FLDM 170 FLDM 170 Overview Copy counters SCATEC SCATEC-15 SCATEC-10 Gripper measuring distance Sd 0... 120 mm 0... 90 mm 0... 60 mm 0... 120 mm optimum operating

More information

MLV41 Series Miniature Sensors

MLV41 Series Miniature Sensors MLV41 Series Miniature Sensors Diffuse Mode with Background Suppression See pages 5-53 Features: Etended sensing range compared to similar housings High insensitivity to target color Sensing Range: 35

More information

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m.

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m. Built-in Amplifier (Medium Size) ES-A Be sure to read Safety Precautions on page 0. Ordering Information Built-in Amplifier s Red light Infrared light Sensing method Appearance Connection method Sensing

More information

3RG7 Opto-BERO Photoelectric Proximity Switches

3RG7 Opto-BERO Photoelectric Proximity Switches K 80 Sensing range 2 m (energetic sensor) Diffuse sensors Modulated infrared light DC or AC/DC M 12 plug or moulded plastic joint IP 67 ON-delay, OFF-delay, pulse shaping Timer 0.01 s to 10 s Enabling

More information

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m.

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m. Built-in Amplifier (Medium Size) ES-A CSM_ES-A_DS_E Be sure to read Safety Precautions on page 0. Ordering Information Built-in Amplifier s Red light Infrared light Sensing method Appearance Connection

More information

Dimensions. Model Number. Electrical connection. Features. Pinout. Indicators/operating means. Product information OQT150-R100-2EP-IO-V31

Dimensions. Model Number. Electrical connection. Features. Pinout. Indicators/operating means. Product information OQT150-R100-2EP-IO-V31 Dimensions.5 8.7 5.5.5. M (x)..5 7. 5.. 0 5.9 7. 9.95 Reveiver Emitter ø. Model Number Triangulation sensor (SbR) with -pin, M8 x connector Features Miniature design with versatile mounting options Multi

More information

Operating instructions Optical distance sensor. OID20x / / 2014

Operating instructions Optical distance sensor. OID20x / / 2014 Operating instructions Optical distance sensor OID0x 800005 / 00 08 / 01 Contents 1 Preliminary note... 1.1 Symbols used... 1. Warning signs used... Safety instructions... Functions and features...5.1

More information

Operating instructions Optical distance sensor. OID25x / / 2015

Operating instructions Optical distance sensor. OID25x / / 2015 Operating instructions Optical distance sensor OID25x 80228366 / 00 03 / 2015 Contents 1 Preliminary note...3 1.1 Symbols used...3 2 Safety instructions...3 3 Functions and features...4 3.1 Applications...4

More information

Operating instructions Optical distance sensor O1D / / 2012

Operating instructions Optical distance sensor O1D / / 2012 Operating instructions Optical distance sensor O1D106 UK 704204 / 01 08 / 2012 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...4 3 Functions and

More information

Photoelectric Sensors E3F2

Photoelectric Sensors E3F2 Photoelectric Sensors E3F2 Threaded Cylindrical Photoelectric Sensors with Built-in Amplifier for Use as an Optical Proximity Switch M18 DIN-sized cylindrical housing Housing materials: plastic, nickel

More information

SENSORS FOR POTENTIALLY EXPLOSIVE AREAS

SENSORS FOR POTENTIALLY EXPLOSIVE AREAS SENSORS FOR POTENTIALLY EXPLOSIVE AREAS Part description Part No.: Device category Operating range [m] Operating voltage source Output Throughbeam sensors = Transmitter = Receiver LS 92 / 3 SE - L Ex 500

More information

Electrical connection

Electrical connection IS 230 Foo & Beverage Inuctive switches Dimensione rawing Part No. 501 11727 20mm 10-30 V DC 100 Hz embee Slim an short cylinrical metal housing M30x1.5 V4A / AISI 316L stainless steel housing ECOLAB teste

More information

OPT2041. Fiber Optic Cable Sensor. Operating Instructions. Available as PDF only Status:

OPT2041. Fiber Optic Cable Sensor. Operating Instructions. Available as PDF only Status: OPT2041 Fiber Optic Cable Sensor Operating Instructions Available as PDF only Status: 18.06.2018 www.wenglor.com Index 1. Proper Use 3 2. Safety Precautions 3 3. General Information Regarding the Device

More information

Oil-resistive, Long-range Photoelectric Sensor with Metal Housing

Oil-resistive, Long-range Photoelectric Sensor with Metal Housing Oil-resistive, Long-range with Metal Housing ES-C Water- and Oil-resistive with Metal Housing Used for Long-range Sensing Satisfies the water- and oil-resistive requirements and safe enough for use in

More information

Operating instructions Optical distance sensor. OID25x / / 2014

Operating instructions Optical distance sensor. OID25x / / 2014 Operating instructions Optical distance sensor OID5x 70608 / 01 08 / 01 Contents 1 Preliminary note... 1.1 Symbols used... Safety instructions... Functions and features....1 Applications... Installation...5.1

More information

Metis M313. Narrow-Band High-End 1-Color Radiation Pyrometer

Metis M313. Narrow-Band High-End 1-Color Radiation Pyrometer Metis M313 Narrow-Band High-End 1-Color Radiation Pyrometer Pyrometer for non-contact temperature measurement in short-wave and narrow-band spectral range for special applications. Wavelength matched to

More information

ML20 Series Long-Range Miniature Sensors

ML20 Series Long-Range Miniature Sensors Diffuse Mode See pages 486-487 Features: Cross-talk immune for 2 units Divergent beam versions available Sensing Ranges: mm, 1 m Output: NPN, PNP Thru-Beam Mode See page 489 Features: Alignment in lens

More information

panasonic.net/id/pidsx/global CCD The sensor can be used for various applications with its binary data output with four different sensing modes.

panasonic.net/id/pidsx/global CCD The sensor can be used for various applications with its binary data output with four different sensing modes. 1123 PHOTO PHOTO PARTICUR Type Edge Sensor SERIES Related Information General terms and conditions... F-3 About laser beam... P.1593~ guide... P.1021~ General precautions... P.1595 Conforming to FDA regulations

More information

Operating instructions Optical distance sensor O1D / / 2008

Operating instructions Optical distance sensor O1D / / 2008 Operating instructions Optical distance sensor O1D155 UK 704391 / 01 11 / 2008 Contents 1 Preliminary note...4 1.1 Symbols used...4 2 Safety instructions...4 3 Functions and features...5 3.1 Applications...5

More information

Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications

Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications Compact size and high performance for the most challenging detection applications Compact dimensions (14x42x25 mm) Background suppression for transparent and shiny objects High speed contrast sensor up

More information

Original operating instructions Fail-safe inductive sensor GF711S / / 2013

Original operating instructions Fail-safe inductive sensor GF711S / / 2013 Original operating instructions Fail-safe inductive sensor GF7S 8528 / 5 / 23 Contents Preliminary note...3. Explanation of symbols...3 2 Safety instructions...4 2. Safety-related requirements regarding

More information

Operation Instruction for CNI Model with PSU-III-LCD

Operation Instruction for CNI Model with PSU-III-LCD Operation Instruction for CNI Model with PSU-III-LCD Caution-Use of controls or adjustments or performance of procedures other than those specified in this manual may result in hazardous radiation exposure.

More information

ML17 Series Tru-Vue TM Sensors

ML17 Series Tru-Vue TM Sensors ML7 Series Tru-Vue TM Sensors Diffuse Mode with Background Suppression See page 44 Features: Ver low color sensitivit Tamper-proof housing with no eternal adjustments Sensing Range: 5 mm Output: 4-in-

More information

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

Rhino Redundancy Module PSM24-REM360S. Operating Instructions Rhino Redundancy Module PSM4-REM360S Operating Instructions RHINO REDUNDANCY MODULE PSM4-REM360S Description With this module and two power supplies of the PSM series (78, 90, 56, 80 and 360 watt models),

More information

Metis M309 / M316 / M318

Metis M309 / M316 / M318 Metis M309 / M316 / M318 High-End 1-Color Radiation Pyrometers Pyrometers for non-contact temperature measurement in short wavelength spectral range, primarily for measurements on metals and bright and

More information

Operating Instructions VEGAMET 381

Operating Instructions VEGAMET 381 Operating Instructions VEGAMET 381 in out Contents Contents 1 About this document... 4 1.1 Function... 4 1.2 Target group... 4 1.3 Symbolism used... 4 2 For your safety... 6 2.1 Authorised personnel...

More information

LASER SENSOR. Series LAS-T5 and LAS-T. Key-Features:

LASER SENSOR. Series LAS-T5 and LAS-T. Key-Features: LASER SENSOR Series LAS-T and LAS-T Key-Features: Content: Technical Data...2 Technical Drawing...3 Teach-In - Diagrams...3 Order Code... measurement ranges from 4 to mm linearity up to ±2 µm resolution

More information

PHOTOSWITCH Distance Measurement Sensor

PHOTOSWITCH Distance Measurement Sensor Installation Instructions Original Instructions Catalog Numbers 45DMS-B8LAT-D4, 45DMS-B8LGT-D5 Topic Description Save these instructions for future use. Description Features Sensor Configuration Precision

More information

Optional integrated laser alignment facilitates simple, fast alignment for long distances or when using mirrors. Stone production Automotive industry

Optional integrated laser alignment facilitates simple, fast alignment for long distances or when using mirrors. Stone production Automotive industry Technical data overview Operating range 0.5 20 m 15 70 m Number of beams, type dependent 2 8 Beam distance, type dependent 300 mm, 400 mm, 450 mm, 500 mm, 600 mm Type according to EN 61 496 Type 4 Enclosure

More information

C5 Series Stainless Steel Photoelectric

C5 Series Stainless Steel Photoelectric C5 Series Stainless Steel Photoelectric Part Number Sensing Range M5 (5 mm) stainless steel - DC 14 models available Diffuse and through-beam styles Long operating distances Compact stainless steel housing

More information

SENSORS. TLμ. Contrast Sensors - TLμ. All registration mark detection applications. Teach-in, Remote settings. Red/green or white LED emission

SENSORS. TLμ. Contrast Sensors - TLμ. All registration mark detection applications. Teach-in, Remote settings. Red/green or white LED emission TLμ All registration mark detection applications Teach-in, Remote settings Red/green or white LED emission Various interchangeable lenses and fiber-optic models Metal housing with orientable optics and

More information

Fork light barriers SOOF

Fork light barriers SOOF Product range overview Method of measurement Size Min. object diameter Max. switching frequency Switching output Type of light Page/ Internet [mm] [mm] [Hz] Metal light barrier SOOF-M- -C30 30x35 0.5 4,000

More information

Original operating instructions Safety relay with relay outputs with and without delay G1502S / / 2016

Original operating instructions Safety relay with relay outputs with and without delay G1502S / / 2016 Original operating instructions Safety relay with relay outputs with and without delay UK G50S 803638 / 00 0 / 06 Contents Preliminary note...4. Symbols used...4 Safety instructions...5 3 Items supplied...6

More information

Opto Proximity Switches

Opto Proximity Switches SIMATIC PXO0 K form Accessories Operating mode Diffuse Retroreflective Thru-beam Sensor for plastic optical fibers Sensing range cm 10 via potentiometer) 0 via potentiometer) 100 via potentiometer) Depends

More information

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600 REDUNDANCY MODULE TSP-REM360 AND TSP-REM600 Operating Instructions Seite 1 Dimensions drawings: TSP-REM360 Weight: 0.882lb Gewicht: 0.40kg Seite 2 Dimensions drawings: TSP-REM600 Bottom view Top view Side

More information

S40 SERIES INSTRUCTION MANUAL

S40 SERIES INSTRUCTION MANUAL S0 SERIES The yellow LED indicates the output status. The green LED ON indicates that the received signal has a safety margin compared to the output switching value. See the paragraph for setup procedure

More information

We Bring Light into the Dark. Reliable Differentiation also of Dark Colors.

We Bring Light into the Dark. Reliable Differentiation also of Dark Colors. We Bring Light into the Dark. Reliable Differentiation also of Dark Colors. Color Control and Color Measurement SPECTRO-3-CL / -JR / -ANA Series True Color Sensors SPECTRO-3-CL Series / SPECTRO-3-JR Series

More information

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

Rhino Buffer Module PSM24-BFM600S. Operating Instructions Rhino Buffer Module PSM24-BFM600S Operating Instructions RHINO BUFFER MODULE PSM24-BFM600S Description The PSM24-BFM600S Buffer Module will hold the output voltage of a 24 VDC power supply after brownouts

More information

BNI IOL Z046. IO-Link 1.1 Sensor hub with extension port User's Guide

BNI IOL Z046. IO-Link 1.1 Sensor hub with extension port User's Guide BNI IOL104002Z046 IOLink 1.1 Sensor hub with extension port User's Guide Balluff Network Interface / IOLink BNI IOL104002Z046 Contents 1 General 4 1.1. Structure of the Manual 4 1.2. Typographical Conventions

More information

The World s Smallest TOF Sensor lineup with analog output type

The World s Smallest TOF Sensor lineup with analog output type 7 New model TOF type with built-in digital panel series The World s Smallest TOF Sensor lineup with analog output type Analog output type and -control-output type The world s smallest TOF sensor Built-in

More information

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections Data sheet 3379_en_B 1 Description PHOENIX CONTACT 2015-07-14 2 Features Media converters provide

More information

L-LAS Series. L-LAS-TB-F-8x1-30/40 L-LAS-TB-F-1x8-30/40. Design. L-LAS Series Laser Line Sensors. Product name:

L-LAS Series. L-LAS-TB-F-8x1-30/40 L-LAS-TB-F-1x8-30/40. Design. L-LAS Series Laser Line Sensors. Product name: L-LAS Series L-LAS-TB-F-8x1-30/40 L-LAS-TB-F-1x8-30/40 - Laser line sensor, 1 mw, class 2 laser product - Visible laser line (red light 670 nm), typ. 9.5 mm x 1.5 mm - Measuring range typ. 8 mm - Resolution

More information

Metis H309 / H316 / H318

Metis H309 / H316 / H318 Metis H309 / H316 / H318 High-Speed 1-Color Radiation Pyrometers High-Speed pyrometers for non-contact temperature measurement in short wavelength spectral range, primarily for measurements on metals and

More information

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH Industriefunkuhren Technical Manual Signal Converter for DIN Rail Mounting Series 4800xx-yy ENGLISH Version: 01.01-19.07.2007 2 / 23 Signal Converter 4800 - V01.01 INPORTANT NOTES Downloading Technical

More information

SENSORS S3Z. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors mm background suppression

SENSORS S3Z. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors mm background suppression S3Z Advanced line of miniature Asian style of photoelectric sensors 5-25 background suppression.7 m proximity, 15 with narrow beam 4 m polarized retroreflective 15 m through beam Standard 3-wire output

More information

VariTrans P Standard-Signal Isolators

VariTrans P Standard-Signal Isolators VariTrans Standard-Signal Isolators Warranty Defects occurring within 5 years from delivery date shall be remedied free of charge at our works (carriage and insurance paid by sender). The professional

More information

ASM1, ASM1E, ASM2E. AS-i Safety Monitor. Subject to change without prior notice. Technische Änderungen vorbehalten /02

ASM1, ASM1E, ASM2E. AS-i Safety Monitor. Subject to change without prior notice. Technische Änderungen vorbehalten /02 ASM1, ASM1E, ASM2E AS-i Safety Monitor 50101229-2009/02 Technische Änderungen vorbehalten Subject to change without prior notice Information on the use of the connecting and operating instructions These

More information

XUK8TAKSMM12 photo-electric sensor - XUK - diffuse - Sn 5m 1Q auto PNP/NPN

XUK8TAKSMM12 photo-electric sensor - XUK - diffuse - Sn 5m 1Q auto PNP/NPN Characteristics photo-electric sensor - XUK - diffuse - Sn 5m 1Q auto PNP/NPN Complementary Enclosure material Lens material Maximum sensing distance Output type Add on input Wire insulation material Status

More information

PHOENIX CONTACT - 07/2006

PHOENIX CONTACT - 07/2006 Buffer module with maintenance-free capacitor-based power storage device INTERFACE Data sheet 102035_03_en PHOENIX CONTACT - 07/2006 Description Short-term mains interruptions are bridged by QUINT BUFFER,

More information

Series 28 Universal Sensors

Series 28 Universal Sensors Series 8 Universal Sensors Diffuse Mode with Background Suppression See pages 548-553 Features: Sharp sensing range cut-off Choice of infrared, visible red and laser light sources Sensing Range: 400 mm,

More information

Original operating instructions Fail-safe inductive sensor GI711S / / 2010

Original operating instructions Fail-safe inductive sensor GI711S / / 2010 Original operating instructions Fail-safe inductive sensor GI7S 704583 / 0 06 / 200 Contents Preliminary note 3. Explanation of symbols 3 2 Safety instructions 4 2. Safety-related requirements regarding

More information

PRODUCT INFORMATION. G6 Global Sensor. Beyond the standard Global sensor the economic way to business class

PRODUCT INFORMATION. G6 Global Sensor. Beyond the standard Global sensor the economic way to business class PRODUCT INFORATION G6 Global Sensor Beyond the standard Global sensor the economic way to business class GTB6 Background suppression photoelectric sensor Sensing distance 25 mm Photoelectric proximity

More information

BIC 1B0-ITA50-Q40KFU-SM4A4A BIC 1B0-IT005-Q40KFU-SM4A4A BIC 2B0-ITA50-Q40KFU-SM4A5A. User s Guide

BIC 1B0-ITA50-Q40KFU-SM4A4A BIC 1B0-IT005-Q40KFU-SM4A4A BIC 2B0-ITA50-Q40KFU-SM4A5A. User s Guide BIC 1B0-ITA50-Q40KFU-SM4A4A BIC 1B0-IT005-Q40KFU-SM4A4A BIC 2B0-ITA50-Q40KFU-SM4A5A User s Guide Table of contents 1 Safety 2 1.1. Installation and startup 2 1.2. General safety instructions 2 Hazardous

More information

FL MC 2000E (SM40) LC

FL MC 2000E (SM40) LC IEC 61850 fiber optic converter with LC fiber optic connection (1310 nm) to convert 100Base-Tx to single- or multi-mode fiber glass Data sheet 3205_en_C 1 Description PHOENIX CONTACT 2014-04-04 2 Features

More information

Mounting. possibilities. Transmitter optics. 8-pole fem. connector Binder Series 712 (PLC) Connecting cable: cab-las8/sps or cab-las8/sps-w

Mounting. possibilities. Transmitter optics. 8-pole fem. connector Binder Series 712 (PLC) Connecting cable: cab-las8/sps or cab-las8/sps-w L-LAS Series L-LAS-TB-50 - Laser line sensor, 1 mw, class 2 laser product - Visible laser line (red light 670 nm), 50 mm light curtain - Measuring range typ. 48 mm - Resolution typ. 30 μm - Integrated

More information

ML17 Series Tru-Vue TM Sensors

ML17 Series Tru-Vue TM Sensors ML7 Series Tru-Vue TM Sensors Diffuse Mode with Background Suppression See page 44 Features: Ver low color sensitivit Tamper-proof housing with no eternal adjustments Sensing Range: 5 mm Output: 4-in-

More information

BOS 73K... BOS 74K...

BOS 73K... BOS 74K... BFB/BOS When there s no space for a photoelectric sensor, there is only one solution: user fiber optics! If there are no particular demands for toughness an ambient temperature or chemical resistance,

More information

Fork light barriers SOOF

Fork light barriers SOOF Product range overview Method of measurement Size Min. object diameter Max. switching frequency Switching output Type of light Page/ Internet [mm] [mm] [Hz] Metal light barrier SOOF-M- -C30 30x35 0.5 4,000

More information

Product description. At a glance. performance in a metal housing coating available Precise autocollimation optics. sensors

Product description. At a glance. performance in a metal housing coating available Precise autocollimation optics. sensors -2 Laser Small photoelectric sensors High-performance photoelectric sensor family with laser optics Product description At a glance performance in a metal housing coating available Precise autocollimation

More information

Thread length. 27 (40) mm. 27 (44) mm. 27 (40) mm. 34 (50) mm. 34 (49) mm. 39 (60) mm. 39 (54) mm. 44 (65) mm. 44 (59) mm

Thread length. 27 (40) mm. 27 (44) mm. 27 (40) mm. 34 (50) mm. 34 (49) mm. 39 (60) mm. 39 (54) mm. 44 (65) mm. 44 (59) mm Long Distance Cylindrical. Extra long for increased protection and sensing performance triple proximity sensors for flush mounting requirements. designed and tested for extra long life. Ordering Information

More information

Sensors. Compact: S60 Series. Compact: S60 Series. Multifunction Optoelectronic Sensors

Sensors. Compact: S60 Series. Compact: S60 Series. Multifunction Optoelectronic Sensors Multifunction Optoelectronic Long operating distance Sensitivity adjustment Independent NO-NC outputs M12 connection with standard NPN or PNP configuration The S60 sensors have a sensitivity adjustment

More information

Temperature Switches

Temperature Switches ETS 00 Series Temperature Switch for Inline and Tank Mounting Applications Description The ETS 00 is a compact electronic temperature switch with 4-digit digital display. Pressure resistant to 8700 psi,

More information

BX80 series High resolution cubic housing area sensor

BX80 series High resolution cubic housing area sensor series sensor warranty features warranty Controlled heightt mm Operating up to m Microprocessor based circuit Sensitivity adjustment Strong Special version with metallic enclosure for high-duty use Protection

More information

SM9000. Magnetic-inductive flow meter. Made in Germany

SM9000. Magnetic-inductive flow meter. Made in Germany Made in Germany Application Application totaliser function; empty pipe detection; for industrial applications Installation connection to pipe by means of an adapter Media conductive liquids; water; hydrous

More information