Form 1574 B1 AND B2 USER S GUIDE

Size: px
Start display at page:

Download "Form 1574 B1 AND B2 USER S GUIDE"

Transcription

1 Form 1574 B1 AND B2 USER S GUIDE

2 B1 AND B2 USER S GUIDE Form November Business Park Drive Temecula CA Phone: OPTO (6786) or Fax: OPTO (6786) or Product Support Services 800-TEK-OPTO ( ) or Fax: support@opto22.com Web: support.opto22.com

3 Form November 2012 Copyright Opto 22. All rights reserved. Printed in the United States of America. The information in this manual has been checked carefully and is believed to be accurate; however, Opto 22 assumes no responsibility for possible inaccuracies or omissions. Specifications are subject to change without notice. Opto 22 warrants all of its products to be free from defects in material or workmanship for 30 months from the manufacturing date code. This warranty is limited to the original cost of the unit only and does not cover installation, labor, or any other contingent costs. Opto 22 I/O modules and solid-state relays with date codes of 1/96 or later are guaranteed for life. This lifetime warranty excludes reed relay, SNAP serial communication modules, SNAP PID modules, and modules that contain mechanical contacts or switches. Opto 22 does not warrant any product, components, or parts not manufactured by Opto 22; for these items, the warranty from the original manufacturer applies. These products include, but are not limited to, OptoTerminal-G70, OptoTerminal-G75, and Sony Ericsson GT-48; see the product data sheet for specific warranty information. Refer to Opto 22 form number 1042 for complete warranty information. Wired+Wireless controllers and brains and N-TRON wireless access points are licensed under one or more of the following patents: U.S. Patent No(s) , RE37802, ; Canadian Patent No ; European Patent No ; French Patent No ; British Patent No ; Japanese Patent No A; German Patent No Opto 22 FactoryFloor, Optomux, and Pamux are registered trademarks of Opto 22. Generation 4, iocontrol, iodisplay, iomanager, ioproject, ioutilities, mistic, Nvio, Nvio.net Web Portal, OptoConnect, OptoControl, OptoDataLink, OptoDisplay, OptoEMU, OptoEMU Sensor, OptoEMU Server, OptoOPCServer, OptoScript, OptoServer, OptoTerminal, OptoUtilities, PAC Control, PAC Display, PAC Manager, PAC Project, SNAP Ethernet I/O, SNAP I/O, SNAP OEM I/O, SNAP PAC System, SNAP Simple I/O, SNAP Ultimate I/O, and Wired+Wireless are trademarks of Opto 22. ActiveX, JScript, Microsoft, MS-DOS, VBScript, Visual Basic, Visual C++, Windows, and Windows Vista are either registered trademarks or trademarks of Microsoft Corporation in the United States and other countries. Linux is a registered trademark of Linus Torvalds. Unicenter is a registered trademark of Computer Associates International, Inc. ARCNET is a registered trademark of Datapoint Corporation. Modbus is a registered trademark of Schneider Electric. Wiegand is a registered trademark of Sensor Engineering Corporation. Nokia, Nokia M2M Platform, Nokia M2M Gateway Software, and Nokia 31 GSM Connectivity Terminal are trademarks or registered trademarks of Nokia Corporation. Sony is a trademark of Sony Corporation. Ericsson is a trademark of Telefonaktiebolaget LM Ericsson. CompactLogix, MicroLogix, SLC, and RSLogix are trademarks of Rockwell Automation. Allen-Bradley and ControlLogix are a registered trademarks of Rockwell Automation. CIP and EtherNet/IP are trademarks of ODVA. All other brand or product names are trademarks or registered trademarks of their respective companies or organizations. ii

4 Table of Contents Chapter 1: Welcome Overview What s In This Guide? Document Conventions For Help Chapter 2: Introduction About Optomux System Configuration Physical Layout Communications Modular Construction Wiring Data Transmission System Throughput Features Digital Optomux Latched Inputs Time Delays Pulse Generation Event Counting Pulse Duration Timers Analog Optomux Analog Input Averaging High/Low Limit Testing Output Waveform Generation High/Low Value Recording Gain and Offset Calculation Summary Chapter 3: Installation and Wiring Physical Installation Mounting iii iii

5 Communications Wiring Host to First Optomux Unit Unit to Unit Installing Digital I/O Modules Installing Analog I/O Modules Power Requirements Connecting the Power Supply Third-Party Power Supply Vendors Brain Board Mounting Selecting the Jumpers Group A Jumpers Group B Jumpers Baud Rate Selection Protocol Selection Address Selection Accessories Power Supplies Adapter Cards Appendix A: Surge Protection Surge Protection For RS-422/485 Communication Links Appendix B: Troubleshooting Troubleshooting Questions and Answers iv

6 2: 1: Welcome Chapter 2 1: Welcome Overview The B1 digital and B2 analog Optomux brain boards are intelligent digital processors that operate as slave devices to a host computer. Each brain board contains a microprocessor that provides the necessary intelligence to communicate with a host computer and also perform control functions at each channel of I/O. B1 and B2 brain boards communicate with the host device using the Optomux protocol over an RS-422/485 serial link, providing low-cost distributed access to both digital and analog I/O. Using a simple serial port with an RS-485 converter, up to 4095 I/O points can be accessed over a distance of several thousand feet at moderate speeds with high reliability. NOTE: B1 and B2 brain boards offer serial communications only. For new installations or replacement boards, E1 and E2 brain boards are recommended instead. E1s and E2s are designed as drop-in replacements for B1s and B2s, but they also offer additional network and protocol options. E1s and E2s can communicate over both serial and Ethernet networks using Optomux, and simultaneously communicate using Modbus/TCP and the OptoMMP memory-mapped protocol over Ethernet. In addition, E1s and E2s can be used with Opto 22 s ioproject software suite. See form #1546, the E1 and E2 Data Sheet, for more information. B1 Digital Brain Board B2 Analog Brain Board 1 1

7 WHAT S IN THIS GUIDE? What s In This Guide? This guide includes the following chapters: Chapter 1: Welcome This chapter. Chapter 2: Introduction Overview of Optomux protocol and hardware. Chapter 3: Installation and Wiring Optomux unit communication wiring, power wiring, installation, and jumpers. Chapter A: Surge Protection Information on getting surge protection for RS-422/485 communication links. Chapter B: Troubleshooting Troubleshooting Questions and Answers. Product Support information on how to get help from Opto 22. Document Conventions Bold typeface indicates text to be typed. Unless otherwise noted, such text may be entered in upper or lower case. (Example: At the DOS prompt, type cd \windows. ) Italic typeface indicates emphasis and is used for book titles. (Example: See the OptoControl User s Guide for details. ) File names appear in all capital letters. (Example: Open the file TEST1.TXT. ) Key names appear in small capital letters. (Example: Press SHIFT. ) Key press combinations are indicated by hyphens between two or more key names. For example, SHIFT-F1 is the result of holding down the SHIFT key, then pressing and releasing the F1 key. Similarly, CTRL-ALT-DELETE is the result of pressing and holding the CTRL and ALT keys, then pressing and releasing the DELETE key. Press (or click ) means press and release when used in reference to a mouse button. Menu commands are sometimes referred to with the Menu > Command convention. For example, Select File > Run means to select the Run command from the File menu. Numbered lists indicate procedures to be followed sequentially. Bulleted lists (such as this one) provide general information. 2

8 CHAPTER 1: WELCOME For Help If you have problems installing or using a B1 or B2 brain and cannot find the help you need in this guide, contact Opto 22 Product Support. Phone: 800-TEK-OPTO ( ) (Hours are Monday through Friday, 7 a.m. to 5 p.m. Pacific Time) NOTE: messages and phone calls to Opto 22 Product Support are grouped together and answered in the order received. Fax: Opto 22 website: support@opto22.com When calling for technical support, be prepared to provide the following information about your system to the Product Support engineer: Software and version being used Controller fi rmware version PC confi guration A complete description of your hardware and operating systems, including: jumper confi guration accessories installed (such as expansion daughter cards) type of power supply types of I/O units installed third-party devices installed (e.g., barcode readers) Specific error messages seen 3 3

9 FOR HELP 4

10 3: 2: Introduction Chapter 3 2: Introduction About Optomux Optomux is a protocol used by a family of intelligent digital and analog I/O (input/output) units that operate as slave devices to a host computer. An Optomux I/O unit is a 4-, 8-, or 16-point assembly that accommodates optically-isolated analog or digital I/O modules. Each Optomux I/O unit consists of a removable brain board and an I/O mounting rack. The removable brain board contains a microprocessor which communicates with the host computer and controls the plug-in I/O modules located on the I/O mounting rack. There are two types of Optomux units: analog and digital. Any combination of analog I/O modules may be plugged into an analog Optomux unit and likewise, any combination of digital I/O modules may be plugged into a digital rack. Analog and digital Optomux units from the SNAP, brick, and Classic rack families can then be combined on the same serial link, providing endless combinations of analog and digital I/O points. Optomux I/O units communicate with the host computer over an RS-485 serial communications link. The serial data link is composed of two twisted pairs and a ground (5 wires) that connect to each Optomux IO unit. It is possible to communicate with up to 256 individual units on a single serial data link for a total of 4,096 digital and analog I/O points. This requires configuring all units (B1 s and B2 s) in Repeat mode. However, this can also be accomplished with all units in Multidrop mode, using a repeater (AC30) after every 32 nodes. The RS-485 serial data link offers excellent noise immunity and long cable lengths. This can dramatically reduce wiring costs by eliminating the need for bringing large bundles of field wiring back to a central control location. Optomux units can be located where the actual control is needed. The Optomux protocol and driver are described in form #1572, the Optomux Protocol Guide. This guide is available on our Web site, The easiest way to find it is to search on the form number. 5 5

11 SYSTEM CONFIGURATION System Configuration Physical Layout The high cost of electrical wiring and the noise susceptibility of analog signals make it desirable to place the control or monitoring point as close to the controlled device as possible. Optomux offers design flexibility, with as few as 4 points or as many as 4,096 points in one physical location. Each Optomux IO unit must be assigned its own unique address, 0 through 255. Considerable installation savings and improved system performance can be realized by placing the control point (Optomux) close to the controlled device. The serial data link between adjacent Optomux IO units consists of two twisted pairs and a common which makes it practical to have an Optomux located at each machine on a factory floor, at each heating or air conditioning unit in an energy management application, or at each instrument in a data acquisition environment. Communications Optomux I/O units can be configured to operate in multidrop or repeat mode via jumpers located on each Optomux protocol brain board. For more information on communications, wiring, and system layout, please refer to the individual data sheet for Optomux protocol brain boards. Modular Construction Each Optomux unit is composed of two components, a brain board and a module mounting rack. For example, the B1 connects to the rack via a 50-pin header connector. The following figure shows a typical B1/mounting rack combination assembly. Figure 1-1: Brain Board and Rack Assembly 6

12 CHAPTER 2: INTRODUCTION Wiring Inputs and outputs are connected to the Optomux mounting rack via an industrial barrier strip with integral cable clamp for each terminal. Spade lugs, other wire terminations, bare wires, and tinned wires are all readily accepted. Serial link connections and power connections are also made via screw terminals. Data Transmission Optomux supports 8 baud rates (300, 600, 1,200, 2,400, 4,800, 9,600, 19.2K, and 38.4K) which are selectable via jumpers located on the Optomux unit. Selection of baud rate often depends upon the capabilities of the host port. Many host computers are limited to 9,600. Modems and radio links usually operate at either 300 or 1,200 baud. System throughput is increased by using the fastest available baud rate. Optomux is capable of using two types of message protocols. The 2-pass protocol is intended for use during normal operation. This protocol requires the transmission of two messages on the serial link every time a command is executed. The host sends a command to an Optomux unit and then receives a response message acknowledging successful execution of the command along with any requested data, or an error message indicating that the Optomux detected an error in the command message and was unable to execute it. A 4-pass protocol is also available. This protocol is sometimes useful during initial setup and installation because it allows the host to examine and display the command message that Optomux received. The command message is echoed back to the host by Optomux for verification, before it can be executed. After the host verifies that the two messages are identical, an execute command gives Optomux the go ahead, the required action is performed, and any requested data is returned. To ensure secure data transmission, every Optomux command message, and every response from Optomux which contains data, includes a calculated checksum. Optomux never executes a command containing a checksum error. System Throughput In most control applications, some points need to be updated more frequently than others. This section will help you estimate the minimum timing between successive events or transactions. The total time required to complete an Optomux instruction is approximately equal to the transmission time of all the characters in the instruction, plus all the characters in the response. The time required for digital Optomux units to respond to a command is typically less than 1 millisecond. Typical analog Optomux response times are from 3 to 7 milliseconds. A total of 15 characters are required to read the ON/OFF status of all 16 positions on a digital Optomux unit. The command sent from the host requesting the status consist of 7 characters; the response from Optomux consists of 8 characters. The following table shows system throughput, assuming that it takes 1 millisecond for Optomux to respond to the host command. Reading the values of 16 analog inputs on an analog Optomux unit requires a total of 79 command/response characters. The command sent by the host consists of 11 characters; the response from Optomux consists of 68 characters. If we assume a response time of 7 milliseconds, the following table shows system throughput based upon reading all 16 positions per transaction. 7 7

13 DIGITAL OPTOMUX Baud Rate ms/ Character Char/ Second Digital Positions/ Second Analog Positions/ Second , , ,000 1, K 0.5 2,000 1, K ,000 3, Table 1-1: Optomux System Throughput Features System performance and throughput are increased by allowing the Optomux I/O unit to do as much processing as possible, thereby reducing serial line activity and host computer processing. The following summary of Optomux capabilities will help you determine which tasks can performed by the B1 or B2 I/O unit. Digital Optomux In addition to ON/OFF control, B1 Optomux units provide: Latched Inputs Any or all input positions can be used to record momentary events by functioning as latches. Each input position can be configured by host command to latch on either OFF-to-ON or ON-to-OFF transitions. The host computer can recall and/or clear the status of these latches. Time Delays Any or all output positions can function in time delay mode. Outputs can be set to operate with four types of delays. Delay before turning OFF Delay before turning ON Pulse ON Pulse OFF Time delays are programmable with a resolution of 10 milliseconds. 8

14 CHAPTER 2: INTRODUCTION Pulse Generation The B1 can be instructed to output a specific number of pulses (with programmable period) at any output position. Continuous square waves can also be generated. Event Counting Any or all input positions can function as event counters to return a count of external events. The count ranges from 0 to 65,535. Each of the event counters can be individually read, stopped, and cleared. Frequencies of up to 400 Hz with a minimum duty cycle of 50 percent can be counted. Pulse Duration Timers Any or all of the input positions can function as pulse duration timers. Either ON or OFF pulses can be timed with a resolution of 10 milliseconds. Analog Optomux In addition to simple input and output, B2 Optomux units perform: Analog Input Averaging The B2 can be instructed to average the values of successive readings. High/Low Limit Testing Input ranges can be established for input positions, causing flags to be set when either high or low limits are exceeded. These flags can be read and/or cleared by the host computer at any time. Output Waveform Generation Square waves, triangle waves, and ramps can be generated at any of the 16 module positions with programmable rates. High/Low Value Recording The B2 can be instructed to remember the highest and lowest readings at input positions for recall by the host computer. Gain and Offset Calculation The B2 can be instructed to calculate and set offsets and gain coefficients for input positions allowing for easy calibration under software control. 9 9

15 SUMMARY Summary In laying out your installation, plan to route the RS-422 data link cable to all points where you need to install Optomux I/O units now and to all points where you may need control in the future. Supply +5 VDC to each Optomux location, preferably with a local power supply. For repeat mode systems, make it diffi cult for anyone to accidently remove the power or data cables from the repeat mode Optomux units. For analog Optomux units, supply +15 and - 15 VDC to power the analog I/O modules. Choose a baud rate and protocol compatible with your host computer, and make this information available to the hardware installer. The installer will need it to set the jumpers on each controller. Assign a unique address to each controller. Addresses may appear in any order from beginning to end of the data link; however, every address must be unique. No two controllers may share the same address. There is no requirement for consecutive addresses. The entire range of addresses may be used. Try to relate the address to a location or function. Outline the functions of the application software. Take advantage of the B1's and B2 s processing capability to off-load host computer processing time and to reduce data link activity. 10

16 4: 3: Installation and Wiring Chapter 4 3: Installation and Wiring Physical Installation Mounting The B1 or B2 Optomux unit can be mounted in any attitude on any flat surface. The mounting rack and removable brain board portion of the Optomux unit are supplied with permanently-attached standoffs. All of the standoffs should be secured for maximum physical strength. Be sure to leave sufficient space between adjacent controllers for the I/O wiring. To ensure reliable and trouble-free communications, the following is recommended: Twisted pair wires must be used for the communications wiring. Typical wire types are Belden p/n #8164, #9728 (4 pair) or equivalent. Use two pairs for the data and use one of the wires from an extra pair for the signal common. The signal common should not be connected to ground. Connect the overall cable shield to ground in one location only. The communication and DC power wiring should be routed or kept separate from any high voltage field wiring. Communications Wiring A complete data link connection at each Optomux unit (except the last in a string) consists of 10 wires: two twisted pairs (4 wires) and a common coming from the computer or previous Optomux unit, and two twisted pairs and a common going to the next Optomux unit. Use 4-pair cable with one of the wires from a pair for the signal common. One pair will be unused. Host to First Optomux Unit The following figures show two possible connections from the host to the first Optomux unit on the serial link. A suggested color code is shown to help avoid wiring errors

17 COMMUNICATIONS WIRING Figure 2-1: Communication Wiring, Host to Optomux Unit Unit to Unit The following figure shows the connection between adjacent Optomux units on the serial link. The Optomux unit at the end of the data link has only 5 wires To Host, From Host, and common. HINT: Always think of the previous Optomux units as the host. Figure 2-2: Optomux Unit to Optomux Unit Communications Wiring 12

18 CHAPTER 3: INSTALLATION AND WIRING Installing Digital I/O Modules CAUTION: Be sure that all Optomux unit power and power to the controlled devices is removed before installing or removing I/O modules. Each position on a digital mounting rack can accept either input or output modules. Install the color-coded I/O modules on the IO mounting rack by inserting the module pins in the sockets on the rack. Secure the modules with the captive Phillips-head screw. Each power I/O module is connected to two barrier strip terminals on the I/O mounting rack. When connecting DC loads or input, the lower-numbered terminal is always more positive. For detailed information concerning module specifications and wiring, refer to the module data sheets. Digital Optomux units only accept modules with 5-volt logic (for example, IDC5). Each digital I/O mounting rack is supplied with an individual 5-amp fuse for each module position. The fuse is installed in a pair of sockets and may be removed with needle-nose pliers. +5 VDC 5V RETURN FIELD WIRING +5 GND 1A FUSE PWR ON FUSE P1 PIN 49 PIN 1 5V JUMPERS BRAIN CONNECTION I/O MODULE Figure 2-3: Digital Mounting Rack 13 13

19 INSTALLING ANALOG I/O MODULES Installing Analog I/O Modules CAUTION: Be sure that all Optomux unit power and power to the controlled devices is removed before installing or removing I/O modules. Installing or removing modules with power applied can destroy the module. Each position on an analog mounting rack can accept either an input or an output module. Install the I/O module that performs the required function. Secure the module with the captive Phillips-head screw. Refer to the module s data sheet for detailed specifications and wiring diagrams for each analog I/O module. +24 VDC +15 VDC +5 VDC 15V COMMON 5V RETURN -15 VDC FIELD WIRING 5V LOGIC COM + 24V 15V -15V A B A B A B A B A B A B A B A B LOOP SUPPLY FUSE (OPTIONAL) TO + - TH + - FH + - FO + - COM OPTO 22 PB16AH COMMUNICATIONS WIRING BRAIN CONNECTOR NOT POWER APPLIED DO CHANGE MODULES WITH 5V LOGIC FUSE ANALOG I/O MODULE Figure 2-4: Analog Mounting Rack 14

20 CHAPTER 3: INSTALLATION AND WIRING Power Requirements DC power must be provided to each Optomux unit. All B1 and B2 boards require +5 volts DC (±.1 VDC) at 0.5 amps.) B2 analog units also require +15VDC and -15 VDC (±.25 VDC). The amount of power required is dependent upon the type and number of analog I/O modules that are plugged into the unit. The B2 requires +15 and -15 volts at 10 milliamps. Power requirements for analog modules are included in the module specifications. To determine what size power supply is needed, add the requirements for each module to the 10 milliamps required by the Optomux mounting rack. Analog racks also provide terminals for a separate +24 volt supply to be used when powering a 4-20 ma loop using 4-20 ma analog I/O modules. For this type of application, the +24 volt supply is required in addition to the supplies mentioned above. Refer to the module s data sheet for information on wiring AD3 and DA3 modules with a loop supply. The current requirements given for the output modules are only for the modules themselves. Load requirements must be added to these to determine total power supply requirements. Although it is possible to distribute DC from a common power supply to several locations, better noise immunity is obtained by having separate power supplies at each physical location where an Optomux unit is installed. A +5 VDC power supply option can be used to provide power to digital Optomux units. The power supply attaches to the I/O mounting rack beneath the removable brain board portion of the Optomux unit. Connecting the Power Supply Connect the 5-volt power to the barrier strip connectors marked + 5V and GND on the mounting rack. If the + 5 volt supply is to be used by more than one Optomux unit or other devices, make sure there is 5 VDC (±.1 V) at each set of terminals on each rack. The communications wiring and the +5-volt and ±15 volt wires should be routed away from any high-voltage field wires. There should only be one earth ground connection per network, typically connected at the host site. If the earth ground connection is at the host site, make sure none of the supplies is connected to earth ground. This method of grounding prevents ground loop problems due to offset voltages appearing between multiple ground points. If an Opto 22 PBSA/B/C power supply is used with the digital racks, the + 5 VDC logic connection is made by the supply when it is screwed to the rack. In this case, the only connection to be made is the 120 VAC (220 VAC or VDC depending on supply type) connection to the PBSA (PBSB or PBSC) supply. Separate or combined + and - 15 VDC (±.25 VDC) supplies can be used to provide power to analog I/O modules. If using combined supplies, make sure that the 5 VDC RETURN line is separate from the 15-volt COMMON line. Otherwise, the isolation of the analog modules will be defeated. CAUTION: Check polarities of all power supply connections before applying power to the Optomux unit. Incorrect polarity may cause damage to the unit

21 POWER REQUIREMENTS Use a consistent color code from power supply to all Optomux units to prevent wiring errors. Size 18 AWG is recommended for power supply wiring. Optomux demo equipment uses the following colors: Red Black Blue Yellow Brown +5 Volts GND +15 Volts -15 Volts GND Figure 2-5: Power Supply Wiring CAUTION: If brain boards are powered up and serial lines are left floating or are connected to RS-485 adapter card without proper biasing, the RX and TX LED lights may float to an unknown state. This may cause confusion as to the actual state of the communication lines and the proper operation of the brain board. We recommend checking to make sure that the communication lines have the proper biasing and termination resistors installed at the two ends of the RS-485 network. 16

22 CHAPTER 3: INSTALLATION AND WIRING Third-Party Power Supply Vendors The following is a list of a few of the many power supply vendors: COMPUTER PRODUCTS INC. Power Conversion Group 2900 Gateway Dr. Pompano Beach, FL (305) ELPAC POWER SYSTEMS 3131 S. Standard Ave. Santa Ana, CA (714) POWER-ONE 740 Calle Plano Camarillo, CA (805) POWER GENERAL 152 Will Drive P.O. Box 189 Canton, MA (617) SOLA 1717 Busse Hwy. Elk Grove Village, IL (312) NOTE: When specifying power supplies for powering Optomux analog units, some manufacturer s triple supplies have the +5 volts and the ±15 volts commons connected, thereby defeating the isolation. To ensure complete isolation, use separate power supplies for the +5 volts and the ±15 volts

23 BRAIN BOARD MOUNTING Brain Board Mounting The brain board mates with the header connector on the rack. The orientation of the digital brain board (B1) should be such that the brain board extends away from the rack. The orientation of the analog brain board (B2) is such that the brain board covers up the communications and power wiring on the analog rack when it is plugged in. Figure 2-6: B1 Brain Board with Digital Mounting Rack Figure 2-7: B2 Brain Board and Rack Assembly 18

24 CHAPTER 3: INSTALLATION AND WIRING Selecting the Jumpers TIP: Use the OptoScan utility as an aid in setting jumpers. There are two groups of jumpers located on each B1 or B2 brain board. The jumpers are labeled Group A and Group B. Group A Jumpers These jumpers route wiring for repeat-mode or multidrop communications and also provide the proper termination and biasing of the RS-422/485 network. All Optomux units on the same network should be configured for either multidrop or repeat mode, but not both. For multidrop operation, verify that the jumpers in group A are installed as follows: X = INSTALLED : X X X X : : : : : X Install jumper A0 and A6 if the Optomux unit is the last unit in the serial data link. For repeat mode settings, all Optomux bus should be jumpered as follows: X : : : : X X X X X : Group B Jumpers This group of jumpers selects the Optomux address and baud rate. Each Optomux unit on the same link must have a unique address (different from all others). All units on the same network should be set for the same baud rate. The following information is required to set the jumpers on a single Optomux unit. Optomux Address (0-255) What is serial baud rate? (300; 1,200; 9,600; 19.2K; 38.4K) Multidrop or Repeat mode 19 19

25 SELECTING THE JUMPERS Baud Rate Selection Jumpers B8, B9, and B11 select the baud rate. Possible configurations are shown below. Table 2-1: Baud Rate Jumper Settings Baud Rate B8 B9 B Not Installed Not Installed Not Installed 600 Not Installed Not Installed Installed 1200 Installed Not Installed Not Installed 2400 Installed Not Installed Installed 4800 Not Installed Installed Installed 9600 Not Installed Installed Not Installed Installed Installed Not Installed Installed Installed Installed Protocol Selection Jumper B10 selects between 2-pass and 4-pass communications protocol. The 2-pass protocol is the recommended protocol because it provides faster and more efficient communications. The 4-pass protocol is mainly for use as a troubleshooting aid. When jumper B10 is installed, 2-pass protocol is selected. The unit can be put into a 4-pass mode by removing the B10 jumper or using the Optomux software command E. Address Selection Jumpers B0 through B7 select the Optomux address. Each Optomux unit on the same network must have a unique address (different from all the others). Addresses are arbitrary and do not need to be sequential (although they must be unique). The following table lists the possible addresses with corresponding jumper configurations. To use the table, find the address you wish to use (0 to 255). To the right of the address is the sequence of jumpers in the following order: B7, B6, B5, B4, B3, B2, B1, and B0. 20

26 CHAPTER 3: INSTALLATION AND WIRING Figure 2-7: Jumper Addresses 21 21

27 ACCESSORIES Accessories There are several ac ces so ries for the Optomux family, ranging from power supplies to adapter cards. Severalare listed be low. Please refer to the Opto 22 Web site ( for detailed in for ma tion on the following products. Power Supplies PBSA, PBSB, PBSC: The PBSx se ries of devices are 5 VDC power supplies that mount directly to dig i tal I/O racks that have a header con nec tor. The power supply mount ing allows an Optomux digital brain board to be mounted on top of the supply, there by saving panel space. The PBSA is for 120 VAC op er a tion, the PBSB is for 240 VAC, and the PBSC is for 12/24 VDC op er a tion. Adapter Cards AC7A, AC7B: This serial adapter card converts any full duplex RS-232 port to an RS-422/485 port, allowingany computer with a serial RS-232 port to communicate to an Optomux network. The AC7A is for 120 VAC operation and the AC7B is for 240 VAC operation. AC8: This serial adapter card converts a half duplex RS-232 serial port to a full duplex RS-422/485 port. The adapter is used for connecting half duplex radio modems to the Optomux network. AC30: This adapter card is an RS-422/485 repeater, used to extend the 5,000 foot limit of an Optomux serial multidrop network. AC31: This adapter is an in tel li gent network interface for the Optomux network. It al lows serial devices (RS-232 or RS-422/485) that are not addressable to re side on the serial Optomux network as slaves to a host computer. Devices may in clude printers, terminals, barcode read ers, counters, motion controllers, etc. PCI-AC48: The PCI-AC48 is an isolated, high-speed adapter card designed to link RS-485 serial devices with computers using the Peripheral Component Interconnect (PCI) bus. This adapter card is ideal for customers who have been using Opto 22 s AC37 adapter card, but must upgrade to a newer computer that uses the PCI bus instead of the ISA bus. 22

28 5: A: AppTitleAppendix A A: Surge Protection Surge Protection For RS-422/485 Communication Links For more information or for catalog requests, contact: Phoenix Contact Inc. P.O Box 4100 Harrisburg, PA info@phoenixcon.com Phone: (717) Fax: (717) Fax-on-demand: (800)

29 SURGE PROTECTION FOR RS-422/485 COMMUNICATION LINKS 24

30 6: A: AppTitleAppendix B B: Troubleshooting Troubleshooting Questions and Answers Q. I send a command to turn on output 5 of an Optomux unit at address 255, and output 4 goes on. A. Module positions are numbered from 0 to 15. Therefore the fifth bit in the bitmask is for position labeled 4. Following are the bitmask values for each position: Position Bitmask

31 TROUBLESHOOTING QUESTIONS AND ANSWERS Q. I send a command to activate several outputs. The Optomux unit responds with no error, but none of my outputs come on. A. If an output does not turn on, check the following: a. Make sure you configured the outputs of the Optomux unit correctly. The unit defaults to all positions configured as inputs on power-up. b. If power was lost at any time and returned, the unit will have lost its configuration. The unit will have reported a N00 error to the first command sent after the power-up to indicate that configuration was lost. c. If using a digital Optomux unit, make sure you are using output modules with a 5 VDC logic voltage (OAC5, ODC5, etc.). Sometimes modules with a 15 VDC or 24 VDC logic voltage (ODC15, OAC24, etc.) are inserted by mistake. The LED may turn on or be dim with the 15 VDC and 24 VDC modules, but there will be no output on the field side. d. If the output LED is on, but the load does not turn on, check the field voltage and wiring. Also, the load may not draw enough current to meet the minimum current requirements of OAC5 modules (20 ma). Q. I send a command message to an Optomux unit at address 0, and I get no response. However, the Optomux s REC light flashes. A. The receive lights on all the Optomux boards wired in a multidrop mode should light whenever a command is sent. Only the unit at the address that matches the command message address should respond. When an Optomux unit responds, the XMT (transmit) light will flash. At high baud rates, and for messages with only a short response ( A only), the flash will be so brief it may be missed visually. If the host receives no response, and no flash of the XMT light is visible at the slowest baud rate (300), then check the following: a. Make sure the address in the command message matches the Optomux address. Check the jumpers. A common mistake is a reversal of jumpers. All address jumpers (B0 through B7) installed are address 0, and all address jumpers (B0 through B7) removed corresponds to address 255. b. Make sure the baud rate is correct between the host and the Optomux unit. All Optomux units on the same link should be configured to the same baud rate. c. Make sure you have a solid +5 volts powering the Optomux unit. If the voltage is too low, the RCV light may flash, but the unit will not be able to respond. Measure the voltage at the unit s power terminals not at the power supply. d. Check to make sure the communications link is wired with the correct polarity and that the A group of jumpers is configured correctly. Q. When I read position 3 of an Optomux analog board, I receive a 0000, which converts to a decimal -4,096 value when I subtract the 1,000 hex offset. A. A -4,096 decimal reading may indicate one of the following: a. You are reading a module position that has no input module installed. b. You are reading a thermocouple module that has no thermocouple installed, or the thermocouple probe is open. c. An ICTD module has the ICTD wired in reverse. d. A 4 20 ma module is wired with reverse polarity. e. The field connections are made to the wrong terminals. Field connections vary with each module. Refer to the module s data sheet for information on wiring each specific module. In general, field connections made to the terminals on the rack are made to the terminals 26

32 APPENDIX B: TROUBLESHOOTING labeled UPPER (closest to module), and if the module has terminals on the top of the module, connections would be made there. Analog racks have the terminal channels labeled from 1 to 4 (or 16). These channels correspond to module positions 0 to 3 (or 15) respectively. f. If all inputs on that board have the same -4,096 reading, then check to make sure the board has +15 and -15 VDC at the corresponding terminals (with reference to the terminal that is marked COMMON). Q. I receive a large number of checksum errors (N02) when I send commands to an Optomux unit. A. Make sure that you are using twisted pair cable. The RS-422/485 network is only reliable when the communications cable is twisted (+ and - lines of EACH pair twisted together) with at least 1/2 twist per inch. Sometimes, the wire is twisted but one of the connections of a pair is actually used as the mate to the opposite pair ( - of one pair used as - of opposite pair). This cross-twist condition is usually due to jacketed twisted pair cables, which have a wire of each pair with the same color code. In this case, strip the jacket back far enough to properly identify the individual pairs. You should also check the Group A jumpers to make sure the termination and bias jumpers are correctly installed

33 TROUBLESHOOTING QUESTIONS AND ANSWERS 28

AC40-FIBER OPTIC REPEATER/ADAPTER USER S GUIDE

AC40-FIBER OPTIC REPEATER/ADAPTER USER S GUIDE AC40-FIBER OPTIC REPEATER/ADAPTER USER S GUIDE Form 526-001009 October, 2000 43044 Business Park Drive, Temecula, CA 92590-3614 Phone: 800-321-OPTO (6786) or 951-695-3000 Fax: 800-832-OPTO (6786) or 951-695-2712

More information

IEC INTEGRATION KIT FOR PAC PROJECT GUIDE

IEC INTEGRATION KIT FOR PAC PROJECT GUIDE IEC60870-5 INTEGRATION KIT FOR PAC PROJECT GUIDE Form 2098 131015 October, 2013 43044 Business Park Drive Temecula CA 92590-3614 Phone: 800-321-OPTO (6786) or 951-695-3000 Fax: 800-832-OPTO (6786) or 951-695-2712

More information

Classic Brain Boards. Classic Brain Boards. Features. Description. Networking. Part Numbers

Classic Brain Boards. Classic Brain Boards. Features. Description. Networking. Part Numbers B2 Analog Brain Board Features Intelligent digital processors. Serial data link operates at selectable baud rates from 300 baud to 38.4 Kbaud Optomux units can be configured for either multidrop or repeat

More information

MODBUS 3.1 INTEGRATION KIT FOR OPTOCONTROL

MODBUS 3.1 INTEGRATION KIT FOR OPTOCONTROL KIT FOR OPTOCONTROL Form 1128-000828 August, 2000 43044 Business Park Drive, Temecula, CA 92590-3614 Phone: 800-321-OPTO (6786) or 951-695-3000 Fax: 800-832-OPTO (6786) or 951-695-2712 www.opto22.com Product

More information

ALLEN-BRADLEY DF1 INTEGRATION KIT FOR PAC CONTROL USER S GUIDE

ALLEN-BRADLEY DF1 INTEGRATION KIT FOR PAC CONTROL USER S GUIDE ALLEN-BRADLEY DF1 INTEGRATION KIT FOR PAC CONTROL USER S GUIDE SNAP PAC Controllers Form 1706-131218 December, 2013 43044 Business Park Drive Temecula CA 92590-3614 Phone: 800-321-OPTO (6786) or 951-695-3000

More information

MODBUS/SERIAL INTEGRATION KIT FOR PAC PROJECT

MODBUS/SERIAL INTEGRATION KIT FOR PAC PROJECT MODBUS/SERIAL INTEGRATION KIT FOR PAC PROJECT Form 1697-111010 October 2011 43044 Business Park Drive Temecula CA 92590-3614 Phone: 800-321-OPTO (6786) or 951-695-3000 Fax: 800-832-OPTO (6786) or 951-695-2712

More information

AC7A/B USER S GUIDE. Form September 2016

AC7A/B USER S GUIDE. Form September 2016 AC7A/B USER S GUIDE Form 0233-160920 September 2016 43044 Business Park Drive Temecula CA 92590-3614 Phone: 800-321-OPTO (6786) or 951-695-3000 Fax: 800-832-OPTO (6786) or 951-695-2712 www.opto22.com Product

More information

SNAP HIGH-DENSITY DIGITAL MODULE USER S GUIDE

SNAP HIGH-DENSITY DIGITAL MODULE USER S GUIDE SNAP HIGH-DENSITY DIGITAL MODULE USER S GUIDE SNAP-IAC-16 SNAP-IAC-A-16 SNAP-IDC-16 SNAP-IDC-32 SNAP-ODC-32-SRC SNAP-ODC-32-SNK Form 1547-070720 July, 2007 43044 Business Park Drive Temecula CA 92590-3614

More information

ALLEN-BRADLEY DF1 INTEGRATION KIT FOR iocontrol USER S GUIDE

ALLEN-BRADLEY DF1 INTEGRATION KIT FOR iocontrol USER S GUIDE ALLEN-BRADLEY DF1 INTEGRATION KIT FOR iocontrol USER S GUIDE SNAP Simple I/O SNAP Ethernet I/O SNAP Ultimate I/O Form 1555-070817 August, 2007 43044 Business Park Drive Temecula CA 92590-3614 Phone: 800-321-OPTO

More information

MODBUS/TCP PROTOCOL GUIDE

MODBUS/TCP PROTOCOL GUIDE MODBUS/TCP PROTOCOL GUIDE For use with: SNAP PAC R-Series Controller SNAP PAC S-Series Controller SNAP PAC EB Brains SNAP Ethernet I/O Units SNAP Simple I/O Units SNAP Ultimate I/O Units E1 I/O Units E2

More information

AC24AT/AC422AT USER S GUIDE

AC24AT/AC422AT USER S GUIDE AC24AT/AC422AT USER S GUIDE Form 166-040823 August, 2004 43044 Business Park Drive, Temecula, CA 92590-3614 Phone: 800/321-OPTO (6786) or 951/695-3000 Fax: 800/832-OPTO (6786) or 951/695-2712 Internet

More information

ALLEN-BRADLEY DF1 INTEGRATION KIT FOR OPTOCONTROL USER S GUIDE

ALLEN-BRADLEY DF1 INTEGRATION KIT FOR OPTOCONTROL USER S GUIDE ALLEN-BRADLEY DF1 INTEGRATION KIT FOR OPTOCONTROL USER S GUIDE Form 0912-070817 August, 2007 43044 Business Park Drive, Temecula, CA 92590-3614 Phone: 800-321-OPTO (6786) or 951-695-3000 Fax: 800-832-OPTO

More information

DNP3 INTEGRATION KIT FOR PAC CONTROL USER S GUIDE

DNP3 INTEGRATION KIT FOR PAC CONTROL USER S GUIDE DNP3 INTEGRATION KIT FOR PAC CONTROL USER S GUIDE Form 1773-140917 September 2014 43044 Business Park Drive Temecula CA 92590-3614 Phone: 800-321-OPTO (6786) or 951-695-3000 Fax: 800-832-OPTO (6786) or

More information

iomanager USER S GUIDE

iomanager USER S GUIDE iomanager USER S GUIDE SNAP Ultimate I/O SNAP Ethernet I/O SNAP Simple I/O SNAP-LCE Controller Form 1440-040930 September, 2004 43044 Business Park Drive Temecula CA 92590-3614 Phone: 800-321-OPTO (6786)

More information

iomanager USER S GUIDE

iomanager USER S GUIDE iomanager USER S GUIDE SNAP Ultimate I/O Units SNAP Ethernet I/O Units SNAP Simple I/O Units SNAP-LCE Controller E1 I/O Units E2 I/O Units Form 1440 iomanager USER S GUIDE SNAP Ultimate I/O SNAP Ethernet

More information

BRAINS SNAP ANALOG AND DIGITAL. DATA SHEET page 1/11. Description

BRAINS SNAP ANALOG AND DIGITAL. DATA SHEET page 1/11. Description DATA SHEET page 1/11 Part Number Description Description B3000-HA 32-channel ARCNET analog and digital brain The B3000-HA is one of Opto 22 s high-performance brains that remotely control a mix of both

More information

BRAINS CLASSIC/MISTIC 16-CHANNEL ANALOG. DATA SHEET page 1/10. Description

BRAINS CLASSIC/MISTIC 16-CHANNEL ANALOG. DATA SHEET page 1/10. Description DATA SHEET page 1/10 Description Part Number B200 Description 16-Channel Analog Brain, Mistic Protocol The B200 is an analog brain board used to control up to 16-channels of remote analog I/O using Opto

More information

SNAP-LCM4 USER S GUIDE

SNAP-LCM4 USER S GUIDE SNAP-LCM4 USER S GUIDE Form 1122-100622 June 2010 43044 Business Park Drive Temecula CA 92590-3614 Phone: 800-321-OPTO (6786) or 951-695-3000 Fax: 800-832-OPTO (6786) or 951-695-2712 www.opto22.com Product

More information

APPLICATION NOTE: OPTOSQL TM PROXY (FORM 1428)

APPLICATION NOTE: OPTOSQL TM PROXY (FORM 1428) APPLICATION NOTE: OPTOSQL TM PROXY (FORM 1428) Contents OptoSQL Proxy on page 3 Overview on page 3; Getting Started on page 6; Using the OPTOSQL Proxy Virtual Link Manager on page 7; OptoProxy Tester on

More information

CLASSIC STANDARD DIGITAL DATA SHEET page 1/4

CLASSIC STANDARD DIGITAL DATA SHEET page 1/4 RACKS DATA SHEET page 1/4 Description The PB8H I/O mounting rack can accomodate up to eight Opto 22 standard (Generation 1) digital single channel I/O modules in any combination. The PB8H is designed to

More information

M4-SERIES CONTROLLER ETHERNET CARD INSTALLATION GUIDE

M4-SERIES CONTROLLER ETHERNET CARD INSTALLATION GUIDE M4-SERIES CONTROLLER ETHERNET CARD INSTALLATION GUIDE Form 1156-100317 March 2010 43044 Business Park Drive Temecula CA 92590-3614 Phone: 800-321-OPTO (6786) or 951-695-3000 Fax: 800-832-OPTO (6786) or

More information

BRAIN BOARDS BRICK ANALOG. DATA SHEET page 1/7. Description

BRAIN BOARDS BRICK ANALOG. DATA SHEET page 1/7. Description BRAIN BOARDS DATA SHEET page 1/7 Description Part Numbers G4A8R Description Remote Analog 8-Channel Multifunction I/O Unit Mistic Protocol The G4A8R is a high performance analog I/O brick for the Opto

More information

INTERFACES. CLASSIC CONTROLLER DATA SHEET page 1/4. Unpacking. Diagram. Figure 1: G4LC32SER Physical Layout

INTERFACES. CLASSIC CONTROLLER DATA SHEET page 1/4. Unpacking. Diagram. Figure 1: G4LC32SER Physical Layout INTERFACES DATA SHEET page 1/4 Unpacking The packing box for the G4LC32SER contains: G4LC32SER daughter card Four RS-485/RS-232 7-position plugs Connector key Part Number G4LC32SER Classic Serial Adapter

More information

SNAP SERIAL COMMUNICATION MODULE USER S GUIDE

SNAP SERIAL COMMUNICATION MODULE USER S GUIDE SNAP SERIAL COMMUNICATION MODULE USER S GUIDE Form 1191-030910 SEPTEMBER 2003 43044 Business Park Drive Temecula CA 92590-3614 Phone: 800-321-OPTO (6786) or 951-695-3000 Fax: 800-832-OPTO (6786) or 951-695-2712

More information

INTERFACES TRADITIONAL PC ADAPTER CARD. DATA SHEET page 1/6. Description

INTERFACES TRADITIONAL PC ADAPTER CARD. DATA SHEET page 1/6. Description INTERFACES DATA SHEET page 1/6 Part Number Description AC24AT ISA Bus Serial Port RS422/485, Isolated Description The AC24AT is an RS-422/485 adapter card that plugs directly into the IBM PC bus and provides

More information

SNAP High-Density Digital I/O Modules

SNAP High-Density Digital I/O Modules SNAP High-Density Digital I/O Modules Features 16 or 32 digital input points or output points in one compact SNAP module Up to 16 high-density digital modules on a SNAP rack, making up to 512 digital points

More information

CLASSIC DATA SHEET page 1/5

CLASSIC DATA SHEET page 1/5 DATA SHEET page 1/5 Description The G4LC32 Controller is a high-performance real-time industrial microcomputer designed to work within the Opto 22 family of rugged and compact controllers and I/O units.

More information

ADAPTER CARDS TRADITIONAL STANDALONE. DATA SHEET page 1/14. Description

ADAPTER CARDS TRADITIONAL STANDALONE. DATA SHEET page 1/14. Description ADAPTER CARDS DATA SHEET page 1/14 Description Part Numbers AC38A Description High Speed RS485 Repeater 120 VAC The AC38 is an optically-isolated RS-485 repeater. AC38 can operate at up to 115.2K baud

More information

BRAIN BOARDS BRICK ANALOG INSTALLATION NOTES

BRAIN BOARDS BRICK ANALOG INSTALLATION NOTES BRAIN BOARDS INSTALLATION NOTES Description page 1/7 Part Numbers Description G4A8L Local Analog 8-Channel Multifunction I/O Unit Mistic Protocol G4D16L Local Digital 16-Channel Multifunction I/O Unit

More information

M2M OPTOGSM I/O DATA SHEET. Description

M2M OPTOGSM I/O DATA SHEET. Description page 1/4 Description OptoGSM I/O from Opto 22 integrates standard wireless GSM/GPRS networks and proven Opto 22 input/output (I/O) technology to provide a low-cost, flexible solution for remote monitoring

More information

SNAP-LCE USER S GUIDE

SNAP-LCE USER S GUIDE SNAP-LCE USER S GUIDE Form 1475-120726 July 2012 43044 Business Park Drive Temecula CA 92590-3614 Phone: 800-321-OPTO (6786) or 951-695-3000 Fax: 800-832-OPTO (6786) or 951-695-2712 www.opto22.com Product

More information

RACKS SNAP N-SERIES DATA SHEET. Description

RACKS SNAP N-SERIES DATA SHEET. Description Description SNAP N-series racks integrate on a single mounting rack a SNAP Ultimate I/O brain, a remote communication adapter, and multiple SNAP analog, digital, and serial I/O modules. N-series racks

More information

SNAP Serial Communication Modules. SNAP Serial Communication Modules. Features. Description. Part Numbers

SNAP Serial Communication Modules. SNAP Serial Communication Modules. Features. Description. Part Numbers SNAP Serial Communication Modules Features SNAP-SCM-232: Two RS-232 serial ports with optional RTS/CTS flow control SNAP-SCM-485-422: Two RS-485 2-wire serial ports or one RS-485/422 4-wire serial port

More information

BRAIN BOARDS DEVICENET 16-CHANNEL DIGITAL. DATA SHEET page 1/7. Description

BRAIN BOARDS DEVICENET 16-CHANNEL DIGITAL. DATA SHEET page 1/7. Description DATA SHEET page 1/7 Description The BD-DEVNET is a 16-channel digital DeviceNetcompatible brain board that allows DeviceNet customers to utilize Opto 22 digital I/O mounting racks on the popular DeviceNet

More information

BRAINS SNAP ANALOG AND DIGITAL. DATA SHEET page 1/19. Features. Description

BRAINS SNAP ANALOG AND DIGITAL. DATA SHEET page 1/19. Features. Description DATA SHEET page 1/19 Part Number Description B3000 Analog/Digital Brain Mistic/Optomux Protocol Features Convenient pluggable connector for removable top mounted field wiring. Ready access to standard

More information

SNAP Serial Communication Modules. SNAP Serial Communication Modules. Features. Description

SNAP Serial Communication Modules. SNAP Serial Communication Modules. Features. Description SNAP Serial Communication Modules Features SNAP-SCM-232: Two RS-232 serial ports with optional RTS/CTS flow control SNAP-SCM-485-422: Two RS-485 2-wire serial ports or one RS-485/422 4-wire serial port

More information

Part Numbers SNAP-ENET-D64 SNAP-ENET-RTC RTCBATT

Part Numbers SNAP-ENET-D64 SNAP-ENET-RTC RTCBATT Features Direct 10/100 Megabit Fast Ethernet connection ITCP/IP and UDP/IP transport Multiple, simultaneous communication and protocol options Description High-performance, flexible SNAP Ethernet brains

More information

INTERFACES TRADITIONAL PC ADAPTER CARDS. DATA SHEET page 1/6. Description

INTERFACES TRADITIONAL PC ADAPTER CARDS. DATA SHEET page 1/6. Description INTERFACES DATA SHEET page 1/6 Description Part Number AC422AT Descrption ISA Bus Serial Port RS422/485, Non-Isolated The AC422AT is a non-isolated RS-422/485 adapter card that plugs directly into the

More information

SNAP Ethernet Brains. SNAP Ethernet Brains. Features. Description

SNAP Ethernet Brains. SNAP Ethernet Brains. Features. Description Features Direct 10/100 Megabit Fast Ethernet connection ITCP/IP and UDP/IP transport Multiple, simultaneous communication and protocol options Description High-performance, flexible SNAP Ethernet brains

More information

SNAP-IT-1U Installation Guide

SNAP-IT-1U Installation Guide Chapter 1 SNAP-IT-1U Installation Guide Introduction The SNAP-IT rack-mount unit is a packaged solution for attaching electrical, electronic, and mechanical devices to an Ethernet network. Once attached

More information

RACKS. CLASSIC STANDARD DATA SHEET page 1/4. Description

RACKS. CLASSIC STANDARD DATA SHEET page 1/4. Description RACKS DATA SHEET page 1/4 Description Part Number PB16T Description 16-Channel I/O Module Rack The PB16T I/O mounting rack accommodates up to 16 single-channel Opto 22 standard (Generation 1) I/O modules.

More information

I/O MODULES G4 ANALOG INPUT. DATA SHEET page 1/4. Description

I/O MODULES G4 ANALOG INPUT. DATA SHEET page 1/4. Description I/O MODULES DATA SHEET page 1/4 Description Part Number AD3 Description 4 To 20 ma Input The AD3 module provides a single channel of transformer and optically isolated current-to-digital conversion. The

More information

SNAP IO4AB LEARNING CENTER USER S GUIDE

SNAP IO4AB LEARNING CENTER USER S GUIDE SNAP IO4AB LEARNING CENTER USER S GUIDE Form 1798-090824 August 2009 43044 Business Park Drive Temecula CA 92590-3614 Phone: 800-321-OPTO (6786) or 951-695-3000 Fax: 800-832-OPTO (6786) or 951-695-2712

More information

Part Numbers. SNAP-AIARMS-i SNAP-AIARMS-i-FM* SNAP-AIVRMS-i SNAP-AIVRMS-i-FM* SNAP-AIMA-i. SNAP-AIMA-iSRC SNAP-AIMA-iSRC-FM* SNAP-AIMA2-i.

Part Numbers. SNAP-AIARMS-i SNAP-AIARMS-i-FM* SNAP-AIVRMS-i SNAP-AIVRMS-i-FM* SNAP-AIMA-i. SNAP-AIMA-iSRC SNAP-AIMA-iSRC-FM* SNAP-AIMA2-i. SNAP Isolated Analog Input Modules Features Channel-to-channel isolation Rugged packaging and convenient pluggable wiring. Accepts up to 14 AWG wire. Factory calibrated; no user adjustment necessary Out-of-range

More information

SNAP PAC BRAINS USER S GUIDE

SNAP PAC BRAINS USER S GUIDE SNAP PAC BRAINS USER S GUIDE SNAP-PAC-EB1 SNAP-PAC-EB2 Form 1690-070504 May 2007 43044 Business Park Drive Temecula CA 92590-3614 Phone: 800-321-OPTO (6786) or 951-695-3000 Fax: 800-832-OPTO (6786) or

More information

Interface Adapter Card. Part Number

Interface Adapter Card. Part Number Features 32-bit processor Built-in diagnostics One dedicated Opto 22 remote I/O port (2-wire RS-485 with interrupt capability) Three RS-232 or RS-485 (2-wire or 4-wire) serial ports, with baud rates up

More information

CONTROLLERS. ISA DATA SHEET page 1/4. Description

CONTROLLERS. ISA DATA SHEET page 1/4. Description CONTROLLERS DATA SHEET page 1/4 Part Number G4LC32-LT Opto 22 Lite Controller The G4LC32-LT ( Lite), is a low-cost, general purpose, industrial microcomputer that is mounted on a standard IBM PC bus card.

More information

OPC Servers. OptoServer, OptoOPCServer, OptoENETServer

OPC Servers. OptoServer, OptoOPCServer, OptoENETServer SNAP I/O System Controller software OptoControl, iocontrol Opto 22 Software Human-Machine Interface software OptoDisplay, iodisplay OPC Servers OptoServer, OptoOPCServer, OptoENETServer Opto 22's SNAP

More information

OPC Servers. OptoServer, OptoOPCServer, OptoENETServer

OPC Servers. OptoServer, OptoOPCServer, OptoENETServer SNAP I/O System Controller software OptoControl, iocontrol Opto 22 Software Human-Machine Interface software OptoDisplay, iodisplay OPC Servers OptoServer, OptoOPCServer, OptoENETServer Opto 22's SNAP

More information

Classic G4 16-Channel Rack. Classic G4 16-Channel Rack. Features. Description. Specifications. Part Number

Classic G4 16-Channel Rack. Classic G4 16-Channel Rack. Features. Description. Specifications. Part Number Features Requires minimum panel space Spare module fuse on board Screw terminals on both control and field connections Negative-true or positive-true logic wiring for output modules Negative-true logic

More information

OPTOCONTROL USER S GUIDE

OPTOCONTROL USER S GUIDE OPTOCONTROL USER S GUIDE FORM 724-100625 JUNE, 2010 43044 Business Park Drive Temecula CA 92590-3614 Phone: 800-321-OPTO (6786) or 951-695-3000 Fax: 800-832-OPTO (6786) or 951-695-2712 www.opto22.com Product

More information

M4SARC Network Interface Card

M4SARC Network Interface Card Description The M4SARC is a coaxial cable ARCNET network interface card for Opto 22 s M4 family of modular controllers. It provides the capability to construct a point-to-point or star topology ARCNET

More information

SNAP-IT-PM Installation Guide

SNAP-IT-PM Installation Guide Chapter 1 SNAP-IT-PM Installation Guide Introduction The Opto 22 SNAP-IT panel-mount unit is a packaged solution for attaching electrical, electronic, and mechanical devices to an Ethernet network. Once

More information

SNAP Digital Output Modules. SNAP Digital Output Modules. Features. Description

SNAP Digital Output Modules. SNAP Digital Output Modules. Features. Description SNAP Digital Output Modules Features Four channels per module Convenient pluggable wiring terminals; accepts up to 14 AWG wire Powered by a single 5-volt supply Channel-specific LEDs Operating temperature:

More information

Part Numbers SNAP-IDC5DFM SNAP-IAC5FM SNAP-IDC5AF. Mutual approved SNAP-IDC5-SW SNAP-IDC5GF SNAP-IDC5-FAST-A. Mutual approved

Part Numbers SNAP-IDC5DFM SNAP-IAC5FM SNAP-IDC5AF. Mutual approved SNAP-IDC5-SW SNAP-IDC5GF SNAP-IDC5-FAST-A. Mutual approved Features Four channels per module 4,000-volt transient isolation Convenient pluggable wiring terminals Channel-specific LEDs UL and CE approved Accepts 22 to 14 AWG wire Factory Mutual approved (part numbers

More information

Standard Analog Current Output Modules

Standard Analog Current Output Modules Standard Analog Current Output Modules Features Provides a a single channel of optically- isolated digitalto-current conversion The T module is transformer isolated, which eliminates any ground loop problems

More information

Mutual approved. Mutual approved. SNAP 6-module retention rail, 25-pack (OEM) SNAP 6-module retention rail (OEM)

Mutual approved. Mutual approved. SNAP 6-module retention rail, 25-pack (OEM) SNAP 6-module retention rail (OEM) Features Four channels per module 4,000-volt transient isolation Convenient pluggable wiring terminals Channel-specific LEDs Operating temperature: 0 to 70 C UL and CE approved Accepts up to 14 AWG wire

More information

SNAP Controllers SNAP-LCE

SNAP Controllers SNAP-LCE Description Features Runs up to 16 iocontrol flowcharts simultaneously Works with all Opto 22 SNAP Ethernet-based I/O units Two serial ports for direct connection to serial devices Communicates on standard

More information

SNAP Digital Output Modules. SNAP Digital Output Modules. Features. Description

SNAP Digital Output Modules. SNAP Digital Output Modules. Features. Description Features Four channels per module Convenient pluggable wiring terminals; accepts up to 14 AWG wire Powered by a single 5-volt supply Channel-specific LEDs Operating temperature: 0 to 70 C UL and CE approved

More information

SNAP Power Supplies. SNAP Power Supplies. Features. Description. Part Numbers

SNAP Power Supplies. SNAP Power Supplies. Features. Description. Part Numbers Features Built-in fuse, ON/OFF power switch, and LED indicator Convenient panel mounting; optional DIN-rail mounting Easy connections Wide input voltage range Factory Mutual approved (except SNAP-PS5U

More information

SNAP High-Density Digital I/O Modules

SNAP High-Density Digital I/O Modules SNAP High-Density Digital I/O Modules Features 16 or 32 digital input points or output points in one compact SNAP module Up to 16 high-density digital modules on a SNAP rack, making up to 512 digital points

More information

PCI-AC5, PCIe-AC5, AC5, and G4AC5 Adapter

PCI-AC5, PCIe-AC5, AC5, and G4AC5 Adapter PCI-AC5, PCIe-AC5, AC5, and G4AC5 Adapter Features Provides direct connection to a wide variety of I/O mounting racks Bidirectional I/O lines allow any combination of input and output modules Includes

More information

Opto 22 Optomux. The Optomux driver provides three methods of operation. Users may use any combination of methods.

Opto 22 Optomux. The Optomux driver provides three methods of operation. Users may use any combination of methods. 1 DESCRIPTION The Optomux Driver allows the FieldServer to transfer data to and from devices over either RS-232 or RS-485 using the Optomux Driver protocol. The Optomux driver is a client only driver and

More information

I/O MODULES QUAD DC INPUT. DATA SHEET page 1/5. Description

I/O MODULES QUAD DC INPUT. DATA SHEET page 1/5. Description I/O MODULES DATA SHEET page 1/5 Description Part Numbers IDC5Q Description 4-Channel DC Input 10 32 VDC, 5 VDC Logic Quad Pak modules contain the equivalent of four singlechannel I/O circuits in a single

More information

3: Networking Options

3: Networking Options Chapter 3 3: Networking Options Introduction You should already be familiar with TCP/IP and Ethernet networking before you set up your SNAP PAC System. If you re using Wired+Wireless controllers and brains,

More information

Part Numbers SNAP-PAC-EB1 SNAP-PAC-EB1-FM

Part Numbers SNAP-PAC-EB1 SNAP-PAC-EB1-FM Features Multi-protocol communications and I/O processor Handles analog, digital, and other SNAP I/O modules all on one mounting rack Distributed intelligence for your SNAP PAC system Choose Ethernet or

More information

Communication Protocols for Opto 22 Products

Communication Protocols for Opto 22 Products Introduction Protocol Descriptions Opto 22 products both current and legacy provide a variety of protocols for communication and options for exchanging data. This technical note describes these protocols

More information

Part Numbers SNAP-PAC-S1 SNAP-PAC-S1-FM SNAP-PAC-S2

Part Numbers SNAP-PAC-S1 SNAP-PAC-S1-FM SNAP-PAC-S2 Features Up to 32 PAC Control flowcharts running simultaneously Two 10/100 Mbps Ethernet interfaces for host and I/O communication over standard Ethernet networks SNAP-PAC-S1: One RS-485 serial port for

More information

SNAP PAC R-Series Controllers. SNAP PAC R-Series Controllers. Features. Description

SNAP PAC R-Series Controllers. SNAP PAC R-Series Controllers. Features. Description Features Rack-mounted industrial controller with I/O processor included. Two independent 10/100 Mbps Ethernet network interfaces One RS-232 port with handshaking, suitable for modem communication using

More information

SNAP PAC Brains. SNAP PAC Brains. Features. Description. Part Numbers. EB Series Brains

SNAP PAC Brains. SNAP PAC Brains. Features. Description. Part Numbers. EB Series Brains Features Multi-protocol communications and I/O processor Handles analog, digital, and other SNAP I/O modules all on one mounting rack Distributed intelligence for your SNAP PAC system Choose Ethernet or

More information

Classic G4 Rack. Classic G4 Rack. Features. Description. Part Numbers

Classic G4 Rack. Classic G4 Rack. Features. Description. Part Numbers Features Requires minimum panel space Built-in fuse tester Spare fuse on board UL recognized, CSA certified, CE approved Uses a single 5, 15, or 24 VDC power supply for control power Description The G4PB24

More information

BRAIN BOARDS SNAP DIGITAL. DATA SHEET page 1/7. Description

BRAIN BOARDS SNAP DIGITAL. DATA SHEET page 1/7. Description DATA SHEET page 1/7 Part Number Description Description -PDPRS64 Profibus-DP Digital Slave Brain With the Profibus-DP brain, you can use state-of-the-art Opto 22 digital I/O hardware with your existing

More information

Part Numbers SNAP-UP1-M64

Part Numbers SNAP-UP1-M64 Features Programmable I/O and communications processor I10/100 Mbps Ethernet, automatic speed negotiation RS-232 serial port for optional modem connection using PPP Simultaneous communication using Modbus/TCP,

More information

G4 Digital DC Input Modules. G4 Digital DC Input Modules. Features. Description. Part Numbers

G4 Digital DC Input Modules. G4 Digital DC Input Modules. Features. Description. Part Numbers Features volts transient optical isolation Built-in LED status indicator Small footprint design, reducing mounting space by approximately 50 percent Built-in filtering for transient suppression and noise

More information

OptoTerminal Operator Interfaces

OptoTerminal Operator Interfaces OptoTerminal Operator Interfaces Features Full-color touch screen interface NEMA-4 front panel; CE certified Complete programming and design software included Provides an effective interactive operator

More information

SNAP TEX Mounting/Wiring Tools and Spare Parts

SNAP TEX Mounting/Wiring Tools and Spare Parts SNAP TEX Mounting/Wiring Tools and Spare Parts Features Securely mount SNAP I/O racks, controllers, and power supplies to DIN rails Easily jumper 4-channel digital I/O modules Commission high-density digital

More information

Part Numbers SNAP-PAC-S1 SNAP-PAC-S2

Part Numbers SNAP-PAC-S1 SNAP-PAC-S2 Features Up to 32 PAC Control flowcharts running simultaneously Two 10/100 Mbps Ethernet interfaces for host and I/O communication over standard Ethernet networks SNAP-PAC-S1: One RS-485 serial port for

More information

4: Installing and Wiring System Components

4: Installing and Wiring System Components Chapter 4 4: Installing and Wiring System Components Introduction This chapter shows you how to install SNAP PAC System components and connect them to field devices. This chapter includes basic information;

More information

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment FAST SHIPPING AND DELIVERY TENS OF THOUSANDS OF IN-STOCK ITEMS EQUIPMENT DEMOS HUNDREDS OF MANUFACTURERS SUPPORTED

More information

G4 Digital DC Output Modules. G4 Digital DC Output Modules. Features. Description. Part Numbers

G4 Digital DC Output Modules. G4 Digital DC Output Modules. Features. Description. Part Numbers Features volts opticalisolation (transient) Built-in LED status indicator Logic levels of 5, 5, and 4 VDC Removable fuse Ability to withstand one-second surge of 5 amps Operating temperature: -0 C to 70

More information

CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE

CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE 13050201 (c) Copyright DIP Inc., 1996 DIP Inc. P.O. Box 9550 MORENO VALLEY, CA 92303 714-924-1730 CONTENTS DN502 PRODUCT OVERVIEW 1 DN502 INSTALLATION 1 POWER

More information

CDN503 HIGH DENSITY I/O ADAPTER USER GUIDE

CDN503 HIGH DENSITY I/O ADAPTER USER GUIDE CDN503 HIGH DENSITY I/O ADAPTER USER GUIDE 13050301 (c) Copyright DIP Inc., 1996 DIP Inc. P.O. Box 9550 MORENO VALLEY, CA 92303 714-924-1730 CONTENTS DN503 PRODUCT OVERVIEW 1 DN503 INSTALLATION 1 POWER

More information

PAC Project 9.0 Release Notes. Welcome to PAC Project 9.0. PAC Project 9.0 Release Notes. PAC Project Basic. PAC Project Professional

PAC Project 9.0 Release Notes. Welcome to PAC Project 9.0. PAC Project 9.0 Release Notes. PAC Project Basic. PAC Project Professional Welcome to PAC Project 9.0 Welcome to version 9.0 of Opto 22 s PAC Project software suite for industrial automation, remote monitoring, and data acquisition applications. PAC Project comes in two forms:

More information

OPTODISPLAY USER S GUIDE

OPTODISPLAY USER S GUIDE OPTODISPLAY USER S GUIDE FORM 723-060620 JUNE, 2006 43044 Business Park Drive Temecula CA 92590-3614 Phone: 800-321-OPTO (6786) or 951-695-3000 Fax: 800-832-OPTO (6786) or 951-695-2712 www.opto22.com Product

More information

PAC Project 8.5 Release Notes. PAC Project 8.5 Release Notes. Welcome to PAC Project 8.5. PAC Project Basic. PAC Project Professional

PAC Project 8.5 Release Notes. PAC Project 8.5 Release Notes. Welcome to PAC Project 8.5. PAC Project Basic. PAC Project Professional Welcome to PAC Project 8.5 Welcome to version 8.5 of Opto 22 s PAC Project software suite for industrial automation, remote monitoring, and data acquisition applications. PAC Project comes in two forms:

More information

MODBUS RTU I/O Expansion Modules - Models C267, C277, and C287. Installation and Operations Manual Section 50

MODBUS RTU I/O Expansion Modules - Models C267, C277, and C287. Installation and Operations Manual Section 50 MODBUS RTU I/O Expansion Modules - Models C267, C277, and C287 Installation and Operations Manual 00-02-0651 09-01-09 Section 50 In order to consistently bring you the highest quality, full featured products,

More information

R325P Single Axis Driver

R325P Single Axis Driver R325P Single Axis Driver User Manual And Commands Guide Version 1.3 Thank you for purchasing the R325P Single-Axis Step & Direction Driver. This product is warranted to be free of manufacturing defects

More information

USER MANUAL MODEL 2017P MODEL 2017P60. RS-232 to 20mA and. RS-232 to 60mA Current Loop Converters

USER MANUAL MODEL 2017P MODEL 2017P60. RS-232 to 20mA and. RS-232 to 60mA Current Loop Converters USER MANUAL MODEL 2017P RS-232 to 20mA and MODEL 2017P60 RS-232 to 60mA Current Loop Converters 07M2017P-E Doc# 073051UE Revised 5/7/96 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 1.0

More information

DIN-191 and DIN-192 SERIES CONVERTER BOXES USERS MANUAL

DIN-191 and DIN-192 SERIES CONVERTER BOXES USERS MANUAL DIN-191 and DIN-192 SERIES CONVERTER BOXES USERS MANUAL REVISED: 8/12/13 DGH CORPORATION PO BOX 5638 MANCHESTER, NH 03108 TELEPHONE: 603-622-0452 FAX: 603-622-0487 WEB: www.dghcorp.com The information

More information

Serial Communication Converters & Adapters Instruction Manual

Serial Communication Converters & Adapters Instruction Manual Serial Communication Converters & Adapters Instruction Manual RS-232 to RS-422/485 Converter Isolated RS-232 to RS-422/485 Converter USB to RS-232 Converter USB to RS-422/485 Converter Isolated USB to

More information

INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual. PCMNET V 7. xx

INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual. PCMNET V 7. xx INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual PCMNET V 7. xx INTEGRATED SYSTEMS AND CONTROLS, INC. PCMNET Users Manual Revised 2/4/2005 2003-2005 Integrated Systems and Control. Inc. PO Box

More information

Building a groov HMI for Allen-Bradley Logix Systems. About groov. Building a groov HMI for Allen-Bradley Logix. A-B Systems and groov

Building a groov HMI for Allen-Bradley Logix Systems. About groov. Building a groov HMI for Allen-Bradley Logix. A-B Systems and groov About groov Opto 22 s groov makes it easy to build and deploy simple, effective operator interfaces for your system. groov is browser-based and uses only Internet standards (HTML5, CSS3, SVG, SSL). That

More information

Torque Control Verifier

Torque Control Verifier Torque Control Verifier Instruction Manual Revision 1.2 September 2002 Please Read and Understand Instructions Before Attempting Installation Torque Control Verifier Contents: Quick Start Introduction

More information

MX200 SERIES Modbus Card 50P GE Zenith Controls. Operation and Maintenance Manual 50R-2200B 12/00

MX200 SERIES Modbus Card 50P GE Zenith Controls. Operation and Maintenance Manual 50R-2200B 12/00 g MX200 SERIES Modbus Card 50P-1105 GE Zenith Controls 50R-2200B 12/00 Operation and Maintenance Manual Table of Contents Overview...01 Page LED Indicator...02 Installation...03 Installing the Network

More information

5B Series 16 Channel Backplane 5B01 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

5B Series 16 Channel Backplane 5B01 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM 5B Series 16 Channel Backplane 5B01 FEATURES Mix and Match 5B Series I/O Module Capability Factory Mutual (FM) Approved Approved for Use in Class I, Division2, Groups A, B, C, and D Locations. CE Certified:

More information

CO-485USB USB to RS-485 CONVERTER TECHNICAL REFERENCE

CO-485USB USB to RS-485 CONVERTER TECHNICAL REFERENCE TABLE OF CONTENTS CO-485USB USB to CONVERTER TECHNICAL REFERENCE Specifications, Description and Technical Support... page 1 Connection Diagram... page 2 Set-Up & Testing... page 3 & 4 Power Supply Shunts...

More information

SNAP PAC S-Series Controllers. SNAP PAC S-Series Controllers. Features. Description. Part Numbers. Ethernet Communication

SNAP PAC S-Series Controllers. SNAP PAC S-Series Controllers. Features. Description. Part Numbers. Ethernet Communication Features Up to 32 PAC Control flowcharts running simultaneously Two 10/100 Mbps Ethernet interfaces for host and I/O communication over standard Ethernet networks Wired+Wireless models add wireless LAN

More information

8520/8520R. User Manual

8520/8520R. User Manual /R User Manual Warranty All products manufactured by SuperLogics are warranted against defective materials for a period of one year from the date of delivery to the original purchaser. Disclaimer SuperLogics

More information

Programmable Logic Controllers Micro850

Programmable Logic Controllers Micro850 ROCKWELL AUTOMATION PROCUREMENT SPECIFICATION PROCUREMENT SPECIFICATION Micro850 NOTICE: The specification guidelines in this document are intended to aid in the specification of products. Specific installations

More information

Features. Description. groov Build. groov View. groov Box. Part Number

Features. Description. groov Build. groov View. groov Box. Part Number Features Ready-made gadgets let you quickly create a browser-based operator interface to monitor and control your company s assets A groov interface runs on any device with a modern web browser regardless

More information